WorldWideScience

Sample records for radon concentrations airborne

  1. Measurement of airborne concentrations of radon-220 daughter products by alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Kerr, G.D.; Ryan, M.T.; Perdue, P.T.

    1978-01-01

    The decay of naturally occurring uranium-238 and thorium-232 produces radon-222 and radon-220 isotopes which can escape into the atmosphere. If these radon gases become concentrated in air, their daughter products may present an inhalation hazard to man. The airborne concentrations of radon-222 can usually be measured very accurately in the presence of normal airborne concentrations of radon-220 and its daughters. In contrast, the measurements of the airborne concentrations of radon-220 daughters are usually complicated by the presence of radon-222 and its daughters even at normally occurring airborne concentrations. The complications involved in these measurements can be overcome in most situations by using an alpha particle spectrometer to distinguish the activity of radon-222 daughters from that due to radon-220 daughters collected on a filter. A practical spectrometer for field measurements of alpha particle activity on a filter is discussed

  2. Airborne geophysical radon hazard mapping

    International Nuclear Information System (INIS)

    Walker, P.

    1993-01-01

    Shales containing uranium pose a radon health hazard even when covered by several meters of overburden. Such an alum shale in southern Norway has been mapped with a joint helicopter borne electromagnetic (HEM) and radiometric survey. Results are compared with ground spectrometer, radon emanometer and radon gas measurements in dwellings, and a model to predict radon gas concentrations from the airborne data is developed. Since the shale is conductive, combining the HEM data with the radiometric channel allows the shale to be mapped with greater reliability than if the radiometric channel were used alone. Radiometrically more active areas which do not pose a radon gas hazard can thus be separated from the shales which do. The ground follow-up work consisted of spectrometer and radon emanometer measurements over a uranium anomaly coinciding with a conductor. The correlation between the airborne uranium channel, the ground uranium channel and emanometry is extremely good, indicating that airborne geophysics can, in this case, be used to predict areas having a high radon potential. Contingency tables comparing both radon exhalation and concentration in dwellings with the airborne uranium data show a strong relationship exists between exhalation and the airborne data and while a relationship between concentration and the airborne data is present, but weaker

  3. Large-scale radon hazard evaluation in the Oslofjord region of Norway utilizing indoor radon concentrations, airborne gamma ray spectrometry and geological mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark Andrew; Strand, Terje; Sundal, Aud Venke; Rudjord, Anne Liv

    2008-01-01

    We test whether airborne gamma ray spectrometer measurements can be used to estimate levels of radon hazard in the Oslofjord region of Norway. We compile 43,000 line kilometres of gamma ray spectrometer data from 8 airborne surveys covering 10,000 km 2 and compare them with 6326 indoor radon measurements. We find a clear spatial correlation between areas with elevated concentrations of uranium daughters in the near surface of the ground and regions with high incidence of elevated radon concentrations in dwellings. This correlation permits cautious use of the airborne data in radon hazard evaluation where direct measurements of indoor radon concentrations are few or absent. In radon hazard evaluation there is a natural synergy between the mapping of radon in indoor air, bedrock and drift geology mapping and airborne gamma ray surveying. We produce radon hazard forecast maps for the Oslofjord region based on a spatial union of hazard indicators from all four of these data sources. Indication of elevated radon hazard in any one of the data sets leads to the classification of a region as having an elevated radon hazard potential. This approach is inclusive in nature and we find that the majority of actual radon hazards lie in the assumed elevated risk regions

  4. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  5. The use of track registration detectors to reconstruct contemporary and historical airborne radon ( sup 2 sup 2 sup 2 Rn) and radon progeny concentrations for a radon-lung cancer epidemiologic study

    CERN Document Server

    Steck, D J

    1999-01-01

    Epidemiologic studies that investigate the relationship between radon and lung cancer require accurate estimates for the long-term average concentrations of radon progeny in dwellings. Year-to-year and home-to-home variations of radon in domestic environments pose serious difficulties for reconstructing an individual's long-term radon-related exposure. The use of contemporary radon gas concentrations as a surrogate for radon-related dose introduces additional uncertainty in dose assessment. Studies of glass exposed in radon chambers and in a home show that radon progeny deposited on, and implanted in, glass hold promise for reconstructing past radon concentrations in a variety of atmospheres. We developed an inexpensive track registration detector for the Iowa Radon Lung Cancer Study (IRLCS) that simultaneously measures contemporary airborne radon concentrations, surface deposited alpha activity density, and implanted sup 2 sup 1 sup 0 Po activity density. The implanted activity is used to reconstruct the cum...

  6. Long-term determination of airborne concentrations of unattached and attached radon progeny using stacked LR 115 detector with multi-step etching

    International Nuclear Information System (INIS)

    Nikezic, D.; Yu, K.N.

    2010-01-01

    We developed the theoretical basis for long-term determination of airborne concentrations of unattached and attached radon progeny. The work was separated into two parts. First, we showed that (stacked and multiply etched) LR 115 detectors could be used to determine airborne concentrations of the short-lived radon progeny, 218 Po and 214 Bi. The equilibrium factor F between radon and its progeny could then be determined through the use of the reduced equilibrium factor F red . The airborne concentrations of 214 Pb could then be determined. Second, we developed a method based on the airborne concentrations of 218 Po, 214 Pb and 214 Bi to determine the parameters of the Jacobi room model, viz., the ventilation rate λ v , aerosol attachment rate λ a , deposition rate of unattached progeny λ d u and the deposition rate of attached progeny λ d u . With these parameters, the unattached fraction f p of the potential alpha energy concentration could also be determined. Knowledge of f p , together with F, would enable more accurate determination of the effective dose in the human lung.

  7. Lithological and seasonal variations in radon concentrations in Cypriot groundwaters

    International Nuclear Information System (INIS)

    Tasoula Kiliari; Anastasia Tsiaili; Ioannis Pashalidis

    2010-01-01

    The paper presents and discusses radon activity concentrations in Cypriot groundwater systems as a function of the background lithology and seasonal/meteorological conditions using an airborne radon monitoring system (ARM) after separation of radon by out-gassing. Radiometric analysis of groundwater samples obtained from non-contaminated systems showed that radon concentration in groundwaters varies strongly (0.1-10 Bq L -1 ) depending mainly on the hosting geological matrix but also to lesser degree on atmospheric/meteorological conditions. The associated excess annual dose has been estimated to range between 10 -6 and 10 -4 mSv y -1 , which is an insignificant contribution to the radiation exposure of the Cypriot population caused by airborne radon (0.5 ± 0.4 mSv y -1 ). (author)

  8. Field investigation of surface-deposited radon progeny as a possible predictor of the airborne radon progeny dose rate.

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J; Field, R William

    2009-08-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginally significantly, reduced the Pdose to 0.65 (90% CI 0.42-0.996), 0.54 (90% CI 0.28-1.02), and 0.66 (90% CI 0.45-0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39-0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55-0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64-0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 additional cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08-2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20-2.45) after adjusting for other factors.

  9. Airborne radon-222 measurement by active sampling with charcoal adsorption and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shizuma, Kiyoshi; Wen, Xiao-qiong; Fukami, Kenji; Iwatani, Kazuo; Hamanaka, Shun-ichi

    1998-01-01

    A simple method for measuring radon concentration in air is presented. Airborne radon is adsorbed in a charcoal bed by an active air sampling. In time, the adsorbed radon comes to attain radioactive equilibrium with its short-lived progeny 214 Pb. Utilizing this fact, radon concentration is derived from γ-ray measurement of 214 Pb. This method is estimated to be capable of detecting radon concentration in air down to 0.79 Bq·m -3 . The adsorption coefficient obtained with the method is compared with what is obtainable with passive sampling. Applications of this method to indoor and outdoor radon measurements are described. (author)

  10. Field Investigation of the Surface-deposited Radon Progeny as a Possible Predictor of the Airborne Radon Progeny Dose Rate

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J.; Field, R. William

    2009-01-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginal significantly, reduced the Pdose to 0.65 (90% CI 0.42–0.996), 0.54 (90% CI 0.28–1.02) and 0.66 (90% CI 0.45–0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39–0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55–0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64–0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 increasing cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08–2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20–2.45) after adjusting for other factors. PMID:19590273

  11. A feasibility study of geogenic indoor radon mapping from airborne radiometric survey in northern Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Wattananikorn, K. [Department of Physics, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)], E-mail: kittic@science.cmu.ac.th; Emharuthai, S. [Department of Physics, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Wanaphongse, P. [Office of Atoms for Peace, Bangkok (Thailand)

    2008-01-15

    Experiments were carried out in seven test sites on three Quaternary alluvial and terrace deposit basins of northern Thailand, to test the possibility of using airborne equivalent uranium to predict geogenic indoor radon values of the region. The methodology was based on the correlation among soil gas permeability, soil radon concentration and indoor radon, as well as a relationship between soil radon and airborne uranium values. The methodology established works rather well when tested in areas of known indoor radon. Based on the predicted values that were obtained from this method, indoor radon in most areas of alluvial and terrace deposit basins of northern Thailand is less than 44Bq/m{sup 3}. There is no area in these basins where predicted indoor radon exceeds 74Bq/m{sup 3}.

  12. Radon potential mapping of the Tralee-Castleisland and Cavan areas (Ireland) based on airborne gamma-ray spectrometry and geology.

    Science.gov (United States)

    Appleton, J D; Doyle, E; Fenton, D; Organo, C

    2011-06-01

    The probability of homes in Ireland having high indoor radon concentrations is estimated on the basis of known in-house radon measurements averaged over 10 km × 10 km grid squares. The scope for using airborne gamma-ray spectrometer data for the Tralee-Castleisland area of county Kerry and county Cavan to predict the radon potential (RP) in two distinct areas of Ireland is evaluated in this study. Airborne data are compared statistically with in-house radon measurements in conjunction with geological and ground permeability data to establish linear regression models and produce radon potential maps. The best agreement between the percentage of dwellings exceeding the reference level (RL) for radon concentrations in Ireland (% > RL), estimated from indoor radon data, and modelled RP in the Tralee-Castleisland area is produced using models based on airborne gamma-ray spectrometry equivalent uranium (eU) and ground permeability data. Good agreement was obtained between the % > RL from indoor radon data and RP estimated from eU data in the Cavan area using terrain specific models. In both areas, RP maps derived from eU data are spatially more detailed than the published 10 km grid map. The results show the potential for using airborne radiometric data for producing RP maps.

  13. Pilot study of the application of Tellus airborne radiometric and soil geochemical data for radon mapping

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D. [British Geological Survey, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom)], E-mail: jda@bgs.ac.uk; Miles, J.C.H.; Green, B.M.R. [Health Protection Agency (HPA) - Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Larmour, R. [Environment and Heritage Service, Department of the Environment, Belfast BT7 2JA (United Kingdom)

    2008-10-15

    The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.

  14. Control methods of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.

    1990-01-01

    Exposure to radon-222 and its progeny in indoor atmosphere can result in significant inhalation risk to the population particularly to those living in houses with much higher levels of Rn. There are three methods generally used for the control of Rn and its progeny concentration in the indoor environment: (1) restricting the radon entry, (2) reduction of indoor radon concentration by ventilation or by aircleaning and (3) removal of airborne radon progeny by aerosol reduction. Prominent process of radon entry in most of the residence appears to be the pressure driven flow of soil gas through cracks or through other openings in the basements slab or subfloor. Sealing off these openings or ventilation of the slab or subfloor spaces are the methods of reducing the radon entry rate. Indoor radon progeny levels can also be reduced by decreasing the aerosol load in the dwellings. The results of a few experiments carried out to study the reduction in the working level concentration of radon, by decreasing the aerosol load are discussed in this paper. (author). 9 tabs., 8 figs., 37 refs

  15. Radon concentrations profiles over the brazilian Amazon basin during wet season

    International Nuclear Information System (INIS)

    Pereira, E.B.; Dias, P.L.S.; Nordemann, D.J.R.

    1991-01-01

    Atmospheric radon measurements were performed airborne in the Brazilian Amazon Basin during the wet season ABLE-2B experiment. The vertical profiles of radon showed a small decrease of concentration with increasing altitude at a rate varying from 6.5 to 11 x 10 - 2 Bq m - 3 km - 1. The calculation of the flux balance of radon in the troposphere above the Amazon Basin indicated a residual flux at the upper boundary of the measurement domain (6 km) of 0.14 atom cm - 2 s - 1. This residue may be associated with the turbulent transport of radon due to cloud activity. (author)

  16. The determination of airborne concentrations of radon and thoron progeny by repetitive alpha counting of filter samples

    International Nuclear Information System (INIS)

    French, Clayton S. Jr.; Skrable, Kenneth W.; Chabot, George E.

    1978-01-01

    Analytical equations have been used to determine the airborne concentrations of the particulate daughters of radon and thoron from five net alpha counts obtained at preset time intervals post sampling. The same expressions were used to propagate the associated standard deviations. These propagated errors were minimized by the selection of optimum sampling and counting intervals. An extensive error analysis examined sources of interference and their influence on the calculated concentrations. This system offers sufficient precision for research applications, yet is simple and inexpensive enough for application in field studies. The radon and thoron daughters measured with this technique are 218 Po, 214 Pb, 214 Bi, 212 Pb, and 212 Bi. Because of the decay kinetics involved, the calculated concentrations of 218 Po and 212 Bi involve the greatest uncertainty. The proper choice of sampling and counting intervals optimizes the system for any one of the above radionuclides or for all five collectively. A sampling time of 15 minutes is best for the simultaneous estimation of all five concentrations. Millipore filter samples were obtained from a large, unventilated sub-basement of the University of Lowell research reactor facility and were counted later in direct contact with the window of a gas flow proportional detector having alpha particle counting efficiencies near 0.4 ca -1 and an alpha background of about 1 c min -1 . A typical 15 minute sample obtained at a flow rate of 2 x 10 4 cm 3 min -1 yielded estimates of the airborne concentrations and relative standard deviations: 218 Po, 4.75 x 10 -9 μCi cm -3 ± 18.9%; 214 Pb, 5.15 x 10 -9 μCi cm -3 ± 2.5%; 214 Bi, 4.86 x 10 -9 μCi cm -3 ± 2.4%; 212 Pb, 1.41 x 10 -10 μCi cm -3 ± 2.0%; and 212 Bi, 2.15 x 10 -10 μCi cm -3 ± 27.0%. (author)

  17. Radon in indoor concentrations and indoor concentrations of metal dust particles in museums and other public buildings.

    Science.gov (United States)

    Carneiro, G L; Braz, D; de Jesus, E F; Santos, S M; Cardoso, K; Hecht, A A; Dias da Cunha, Moore K

    2013-06-01

    The aim of this study was to evaluate the public and occupational exposure to radon and metal-bearing particles in museums and public buildings located in the city of Rio de Janeiro, Brazil. For this study, four buildings were selected: two historic buildings, which currently house an art gallery and an art museum; and two modern buildings, a chapel and a club. Integrated radon concentration measurements were performed using passive radon detectors with solid state nuclear track detector-type Lexan used as nuclear track detector. Air samplers with a cyclone were used to collect the airborne particle samples that were analyzed by the particle-induced X-ray emission technique. The average unattached-radon concentrations in indoor air in the buildings were above 40 Bq/m(3), with the exception of Building D as measured in 2009. The average radon concentrations in indoor air in the four buildings in 2009 were below the recommended reference level by World Health Organization (100 Bq/m(3)); however, in 2011, the average concentrations of radon in Buildings A and C were above this level, though lower than 300 Bq/m(3). The average concentrations of unattached radon were lower than 148 Bq/m(3) (4pCi/L), the USEPA level recommended to take action to reduce the concentrations of radon in indoor air. The unattached-radon average concentrations were also lower than the value recommended by the European Union for new houses. As the unattached-radon concentrations were below the international level recommended to take action to reduce the radon concentration in air, it was concluded that during the period of sampling, there was low risk to human health due to the inhalation of unattached radon in these four buildings.

  18. Variations of airborne and waterborne Rn-222 in houses in Maine

    Energy Technology Data Exchange (ETDEWEB)

    Hess, C.T.; Weiffenbach, C.V.; Norton, S.A. (Maine Univ., Orono (USA))

    1982-01-01

    Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon were used for dynamic studies in 18 houses, determining the component of airborne radon associated with showers, laundry and dishwashing, which liberate radon in bursts. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 +- 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties.

  19. Variations of airborne and waterborne Rn-222 in houses in Maine

    International Nuclear Information System (INIS)

    Hess, C.T.; Weiffenbach, C.V.; Norton, S.A.

    1982-01-01

    Concentrations of airborne radon ranging from 0.05 to 135 pCi/L were found in houses in Maine. To investigate the association between elevated radon concentrations in well water and the indoor airborne radon concentrations, the radon in the water supplies of these houses was measured by liquid scintillation. Monitors of airborne radon were used for dynamic studies in 18 houses, determining the component of airborne radon associated with showers, laundry and dishwashing, which liberate radon in bursts. The component of airborne radon associated with water sources was found to vary inversely with ventilation rate and directly with waterborne radon concentration, with 0.8 +- 0.2 pCi Rn/L air per nCi Rn/L water at a ventilation rate of 1.0 air change per hour. The data are pertinent to a study which has revealed significant correlations between county averages, from the National Cancer Institute, or age-adjusted cancer mortality rates in Maine and average values of radon concentrations in water for the counties. (author)

  20. Radon emanation and soil moisture effects on airborne gamma-ray measurements

    International Nuclear Information System (INIS)

    Grasty, R.L.

    1997-01-01

    A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical and experimental results demonstrate that any estimate of the natural gamma-ray field caused by radium in the ground must take into consideration the radon emanation coefficient of the soil. The radon diffusion coefficient of the soil must also be considered since it depends strongly on soil moisture. This has significant implications for the assessment of outdoor radiation doses using laboratory analyses of soil samples and the use of ground and airborne gamma-ray measurements for radon potential mapping

  1. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations. Revision

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-11-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. The experiments were conducted in a room-size chamber using cigarette smoke and radon injection from an external source. Of the devices examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be essentially negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. At the low particle concentrations, deposition of the unattached radon progeny on room surfaces was found to be a significant removal mechanism. Deposition rates of attached and unattached progeny have been estimated from these data, and were used to calculate the equilibrium factors for total and unattached progeny concentrations as a function of particle concentration. While particle removal reduces total airborne radon progeny concentrations, the relative alpha decay dose to the lungs appears to change very little as the particle concentration decreases due to the greater radiological importance of unattached progeny

  2. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  3. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  4. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  5. Indoor concentrations of radon 222 and its daughters: sources, range, and environmental influences

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1985-04-01

    The author here reviews what is presently known about factors affecting indoor concentrations of radon 222 and its daughters. In US single-family homes, radon concentrations are found to average about 1.5 pCi/1, but substantially higher concentrations occur frequently: perhaps a million US homes have concentrations exceeding 8 pCi/1 (from which occupants receive radiation doses comparable to those now experienced by uranium miners). The major contributor to indoor radon is ordinary soil underlying homes, with this radon being transported indoors primarily by the slight depressurization that occurs toward the bottom of a house interior (due to indoor-outdoor temperature differences and winds). Water from underground sources contributes significantly in a minority of cases, primarily residences with private wells, with public water supplies contributing only a few percent of indoor radon, even when drawn from wells. The strong variability in indoor concentrations is associated primarily with variability in the amount of radon entering homes from these various sources, and secondarily with differences in ventilation rates. However, for a given entry rate, the ventilation rate is the key determinant of indoor concentrations. Human doses are also influenced strongly by the chemical behavior of the daughters (i.e., decay products of radon), and considerable progress has been made recently in investigating a major aspect of this behavior, i.e., the manner in which daughters attach to airborne particles, to walls, and - indeed - to the lining of the lung itself, where the key radiation dose occurs

  6. Interaction of radon progeny with atmospheric aerosols

    International Nuclear Information System (INIS)

    Morawska, Lidia

    1994-01-01

    The radiological health hazard due to the airborne radon progeny depends on three factors (i) radon concentration in the air, (ii) radon progeny concentration, and (iii) active particle size distribution. Conclusions as to the health hazard cannot be drawn without full understanding of the interaction mechanisms between radon progeny and atmospheric aerosols. The aim of this work was to study the interaction mechanisms between radon progeny, natural environmental aerosols and environmental tobacco smoke (ETS). The experiments were performed under controlled laboratory conditions of radon concentration (1.85 and 3.70 Bq m -3 ), relative humidity (35, 50, 75 and 95%) and ETS generation. The size distribution of radioactivity carrying aerosols was measured using a wire screen diffusion battery system and size distribution of all airborne aerosols using a differential mobility particle sizer. The paper presents and discusses the results of activity size distribution and radon progeny concentration measurements for different environmental conditions. 7 refs., 2 tabs

  7. The measurement of airborne rodon daughter concentrations in the atmosphere

    International Nuclear Information System (INIS)

    Ha, C.W.; Lee, J.K.; Moon, P.S.

    1979-01-01

    A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also inventigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments. (author)

  8. Ion climate and radon concentration

    International Nuclear Information System (INIS)

    Busbarna, L.

    1981-01-01

    Characteristic values of radon concentration in natural ion climate and in open air were compared and the effect of artificially produced negative ion excess on the radon concentration of air was studied. The results show that the radon concentration measurable at the rise of negative ion excess is smaller than that in the case of natural equilibrium. This effect can be utilized lowering the background of the scintillation chambers, thus increasing their sensitivity. The negative ions of the artificial ion climate lower radon concentration in closed space. The question arises whether only the ion climate is responsible for the effects on the organism and on the nervous system or the radon concentration of the air also contributes to them. (author)

  9. Monitoring of radon concentration in dwellings

    International Nuclear Information System (INIS)

    Kurosawa, Ryuhei

    1991-01-01

    Radon problems in dwellings have recently received much attention. Radon concentration in dwellings, as well as in the general environment, varies with various factors such as meteorological conditions and soil components. Therefore, a long term monitoring of radon concentration is required to obtain an average concentration. This paper reviews a passive type radon monitor that is handy and allows a long term radon monitoring. It provides the structure and principle of the radon monitor, covering the type, filter function, sensitivity of diffusion collecting type (cup type), electrostatic collecting type, adsorption collecting type, and detector of radon monitor. Actual examples of the radon monitor are also given. Radon daughter nuclides will have become major foci of exposure countermeasures. In the future, the development of a passive type monitor for determining potential alpha energy concentration is required. (N.K.)

  10. Indoor radon concentration in Poland

    International Nuclear Information System (INIS)

    Mamont-Ciesla, K.; Jagielak, J.; Rosinski, S.W.; Sosinka, A.; Bysiek, M.; Henschke, J.

    1996-01-01

    Preliminary survey of Rn concentration indoors by means of track detectors and y-ray dose rate with the use of TLD in almost 500 homes in selected areas of Poland was performed in the late 1980s. It was concluded that radon contributes 1.16 mSv i.e. about 46 per cent of the total natural environment ionizing radiation dose to the Polish population. Comparison of the average radon concentrations in 4 seasons of a year and in 3 groups of buildings: masonry, concrete and wood, revealed that the ground beneath the building structure is likely the dominant source of radon indoors. Since the National Atomic Energy Agency in its regulations of 1988-03-31 set up the permissible limit of the equilibrium equivalent concentration of radon in new buildings (equal 100 Bq/m3), the nation-scale survey project for radon in buildings has been undertaken. These regulations were supposed to take effect in 1995-01-01. The project has 3 objectives: to estimate the radiation exposure due to radon daughters received by Polish population to identify radon-prone areas in Poland to investigate dependence of the indoor radon concentrations on such parameters as: type of construction material, presence (or absence) of cellar under the building, number of floor

  11. Comparative survey of outdoor, residential and workplace radon concentrations

    International Nuclear Information System (INIS)

    Barros, Nirmalla; Field, R. William; Field, Dan W.; Steck, Daniel J.

    2015-01-01

    This study investigated radon concentrations in above-ground (i.e. first floor) workplace in Missouri and compared them with above-ground radon concentrations in nearby homes and outdoor locations. This study also examined the potential utility of using home and outdoor radon concentrations to predict the radon concentration at a nearby workplace (e.g. county agencies and schools). Even though workplace radon concentrations were not statistically different from home radon concentrations, the radon concentration at a particular home, or outdoor location, was a poor predictor of the radon concentration at a nearby workplace. Overall, 9.6 and 9.9 % of homes and workplace, respectively, exhibited radon concentrations of ≥148 Bq m -3 . Because of the percentage of workplace with elevated radon concentrations, the results suggest that additional surveys of workplace radon concentrations are needed, especially in areas of high radon potential, to assess the contribution of workplace radon exposure to an individual's overall radon exposure. (authors)

  12. Spectral-ratio radon background correction method in airborne γ-ray spectrometry based on compton scattering deduction

    International Nuclear Information System (INIS)

    Gu Yi; Xiong Shengqing; Zhou Jianxin; Fan Zhengguo; Ge Liangquan

    2014-01-01

    γ-ray released by the radon daughter has severe impact on airborne γ-ray spectrometry. The spectral-ratio method is one of the best mathematical methods for radon background deduction in airborne γ-ray spectrometry. In this paper, an advanced spectral-ratio method was proposed which deducts Compton scattering ray by the fast Fourier transform rather than tripping ratios, the relationship between survey height and correction coefficient of the advanced spectral-ratio radon background correction method was studied, the advanced spectral-ratio radon background correction mathematic model was established, and the ground saturation model calibrating technology for correction coefficient was proposed. As for the advanced spectral-ratio radon background correction method, its applicability and correction efficiency are improved, and the application cost is saved. Furthermore, it can prevent the physical meaning lost and avoid the possible errors caused by matrix computation and mathematical fitting based on spectrum shape which is applied in traditional correction coefficient. (authors)

  13. Indoor radon concentrations in Vushtrri, Kosovo

    International Nuclear Information System (INIS)

    Xhafa, B.; Jonuzaj, A.; ); Bekteshi, S.; Ahmetaj, S.; Kabashi, S.; )

    2009-01-01

    Indoor air radon concentration was measured by exposing trac ketch detectors in the two elementary schools, one high school, a kindergarten and the hospital in the city of Vushtrri. Measurements were performed with the radon monitor PRM-145, which uses alpha scintillation cells and serves to determine the current concentration of radon. The results we obtained are in the range between the average values of radon for the interior spaces, and values that pose a potential risk for lung cancer. Measuring the concentration of radon was done in total of 34 rooms and came up with values which are between 28Bqm -3 and 398Bqm -3 . In order to reduce the concentration of radon, we have built a ventilation pump, then we performed repeated measurements and finally came with results between 130-145Bqm -3 .

  14. Effect of indoor-generated airborne particles on radon progeny dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Trassierra, C. Vargas [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); Stabile, L., E-mail: l.stabile@unicas.it [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); Cardellini, F.; Morawska, L. [National Institute of Ionizing Radiation Metrology (INMRI-ENEA), Rome (Italy); Buonanno, G. [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane (Australia)

    2016-08-15

    Highlights: • Investigation of the interaction between particles and radon progeny dynamics. • Measurements of particles emitted by different indoor sources. • Tests performed in a controlled radon chamber. • Particle size strongly influences the radon progeny dynamics. • Particle surface area concentration is the key parameter of the radon-particle interaction. - Abstract: In order to investigate the interaction between radon progeny and particles, an experimental campaign was carried out in a radon chamber at the Italian National Institute of Ionizing Radiation Metrology, quantifying the amount of attached and unattached radon daughters present in air, as well as the equilibrium factor in the presence of particles generated through indoor sources. A fixed radon concentration was maintained, while particles were generated using incense sticks, mosquito coils and gas combustion. Aerosols were characterized in terms of particle concentrations and size distributions. Simultaneously, radon concentration and attached/unattached potential alpha energy concentration in the air were continuously monitored by two different devices, based on alpha spectroscopy techniques. The presence of particles was found to affect the attached fraction of radon decay products, in such a way that the particles acted as a sink for radionuclides. In terms of sources which emit large particles (e.g. incense, mosquito coils), which greatly increase particle surface area concentrations, the Equilibrium Factor was found to double with respect to the background level before particle generation sessions. On the contrary, the radon decay product dynamics were not influenced by gas combustion processes, mainly due to the small surface area of the particles emitted.

  15. The use of mapped geology as a predictor of radon potential in Norway.

    Science.gov (United States)

    Watson, Robin J; Smethurst, Mark A; Ganerød, Guri V; Finne, Ingvild; Rudjord, Anne Liv

    2017-01-01

    Radon exposure is considered to cause several hundred fatalities from lung-cancer each year in Norway. A national map identifying areas which are likely to be exposed to elevated radon concentrations would be a useful tool for decision-making authorities, and would be particularly important in areas where only few indoor radon measurements exist. An earlier Norwegian study (Smethurst et al. 2008) produced radon hazard maps by examining the relationship between airborne gamma-ray spectrometry, bedrock and drift geology, and indoor radon. The study was limited to the Oslo region where substantial indoor radon and airborne equivalent uranium datasets were available, and did not attempt to test the statistical significance of relationships, or to quantify the confidence of its predictions. While it can be anticipated that airborne measurements may have useful predictive power for indoor radon, airborne measurement coverage in Norway is at present sparse; to provide national coverage of radon hazard estimates, a good understanding of the relationship between geology and indoor radon is therefore important. In this work we use a new enlarged (n = 34,563) form of the indoor radon dataset with national coverage, and we use it to examine the relationship between geology and indoor radon concentrations. We use this relationship to characterise geological classes by their radon potential, and we produce a national radon hazard map which includes confidence limits on the likelihood of areas having elevated radon concentrations, and which covers the whole of mainland Norway, even areas where little or no indoor radon data are available. We find that bedrock and drift geology classes can account for around 40% of the total observed variation in radon potential. We test geology-based predictions of RP (radon potential) against locally-derived estimates of RP, and produce classification matrices with kappa values in the range 0.37-0.56. Our classifier has high predictive value

  16. Radon in dwellings and laboratories from central Mexico

    International Nuclear Information System (INIS)

    Segovia, N.; Pena, P.; Gaso, M.I.; Ponciano, G.

    2003-01-01

    Average indoor radon and airborne particles concentration levels have been measured in family houses, offices and laboratories within a survey protocol related to smoking health effects. The radon measurements were performed with Honeywell A9000A devices. Airborne particle fluctuations were determined using a Personal Data Logging Real Time Aerosol Monitor. The indoor radon average value obtained in the family houses was 40 Bq m -3 . However, short term peaks higher than 150 Bq m -3 were eventually observed. At the offices and laboratories indoor radon behaviour showed several values higher than the limits, particularly for those rooms having no external windows. Airborne PM10 average particulate matter indoors at a smoker house was 0.751 ± 0.420 mg m -3 in 24 h, reaching concentrations as high as 1.6 mg m -3 , one order of magnitude higher than the maximum permissible limit of outdoor PM10 (0.150 mg m -3 ) established by the Mexican legislation. (orig.)

  17. Radon in dwellings and laboratories from central Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Pena, P.; Gaso, M.I. [Inst. Nacional de Investigaciones Nucleares, Mexico D. F. (Mexico); Ponciano, G. [Facultad de Medicina, UNAM, Ciudad Univ., Mexico D.F. (Mexico)

    2003-07-01

    Average indoor radon and airborne particles concentration levels have been measured in family houses, offices and laboratories within a survey protocol related to smoking health effects. The radon measurements were performed with Honeywell A9000A devices. Airborne particle fluctuations were determined using a Personal Data Logging Real Time Aerosol Monitor. The indoor radon average value obtained in the family houses was 40 Bq m{sup -3}. However, short term peaks higher than 150 Bq m{sup -3} were eventually observed. At the offices and laboratories indoor radon behaviour showed several values higher than the limits, particularly for those rooms having no external windows. Airborne PM10 average particulate matter indoors at a smoker house was 0.751 {+-} 0.420 mg m{sup -3} in 24 h, reaching concentrations as high as 1.6 mg m{sup -3}, one order of magnitude higher than the maximum permissible limit of outdoor PM10 (0.150 mg m{sup -3}) established by the Mexican legislation. (orig.)

  18. Radiometers for radon concentration in air

    International Nuclear Information System (INIS)

    Bartak, J.; Machaj, B.; Pienkos, J.P.

    2002-01-01

    Constant grow of science and technology stimulates development of new improved measuring tools. New measuring demand arise also in radon concentration measurements. Varying rock stress and rock cracks influencing radon emanation encouraged research aimed at use of this phenomenon to predict crumps of mine formation among others based on variation of radon emanation. A measuring set was developed in the Institute of Nuclear Chemistry and Technology enabling long term monitoring of radon concentration in mine bore-hole. The set consists probe and probe controller. Detection threshold of the probe is 230 Bq/m 3 . The set can operate in the environment with methane explosion hazard. A radiometer employing Lucas cell as radiation detector for radon concentration in air was also developed its detection threshold is approx. 10 Bq/m 3 . Replaceable Lucas cell of the radiometer allows for measurement of high as well as low radon concentration in short time interval. (author)

  19. Final survey reports on radon concentration in Japan

    International Nuclear Information System (INIS)

    1997-03-01

    In order to grasp the present state of indoor radon concentration all over Japan, this survey was conducted in five years from Heisei 4 FY to 8 FY. Measurements were conducted using a radon and thoron separation apparatus so as to enable to develop radon and thoron separately. This was only one survey all over Japan obtained the only radon concentration by removing thoron perfectly. However, it was planned to obtain the mean indoor radon concentration all over Japan by limiting 20 houses for measurement aim because of limitation on numbers of the apparatus. In this survey, no extremely high region of the radon concentration was found. However, it was comparatively higher in Chugoku, Kinki and Kyushu-Okinawa areas, but was comparatively low in Kanto area. These results showed the same tendency as those of γ-ray level from the ground, and the radon concentration also showed temperature difference of a tendency of higher west and lower east. In this survey, seasonal variation of the radon concentration was found. In the third quarter (from October to December) maximum radon concentration (mean value: 15 Bq/cu m) and in the second quarter, the minimum concentration (mean value: 9 Bq/cu m) were observed, respectively. On comparing the indoor radon concentration of each housing structure used in enquete survey, concrete block house showed higher radon concentration. On its arithmetic mean, the radon concentration was high in order of concrete, steel frame, and wood constructions, and lowest in prefabricated house. The radon concentration of the concrete construction showed about 1.8 times higher than that of the wood construction. (G.K.)

  20. Metrology of radon and thoron concentrations

    International Nuclear Information System (INIS)

    Durcik, M; Vicanova, M.

    1998-01-01

    The alpha spectrometry measurements of radon (radon-222) and thoron (radon-220) concentrations by ionisation chamber, used only in laboratory conditions are described in this paper. For the measurements of radon and thoron in dwellings and work areas was proposed diffusion double chamber detector with track detector. The described dosimeter is very useful for routine measurement and would be applied in measuring of radon and thoron concentrations in caves and dwellings. Big disadvantage of the dosimeter is small holes in cover and it could not be used in dusty areas. From previous measurements of the equilibrium equivalent thoron concentrations by semiconductor detector the measured values ranged from 0.1 to 5.6 Bq m -3 in the Slovak kindergartens were obtained

  1. Radon concentration in The Netherlands

    International Nuclear Information System (INIS)

    Meijer, R.J. de; Put, L.W.; Veldhuizen, A.

    1986-02-01

    In 1000 dwellings, which can be assumed to be an reasonable representation of the average Dutch dwellings, time averaged radon concentrations, radon daughter concentrations and gamma-exposure tempi are determined during a year with passive dosemeters. They are also determined outdoor at circa 200 measure points. (Auth.)

  2. Assessment of indoor radon gas concentration change of college

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul [Dept. of of Radiological Technology, Shingu College, Seongnam (Korea, Republic of); Lee, Ju Young [Dept. of Radiological Technology, Songho College, Hoengseong (Korea, Republic of)

    2017-03-15

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction.

  3. Assessment of indoor radon gas concentration change of college

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Jeong, Eui Hwan; Kim, Hak Jae; Lyu, Kang Yeul; Lee, Ju Young

    2017-01-01

    The purpose of this study was to assess the impact by comparing the concentration of indoor radon and look for ways to lower the concentration of indoor radon gas measurements of three variables, the year of completion, volume of the building and ventilation. Measurement target is six classrooms on the sixth floor of building that was constructed in 1973 and was extended in 2011. Selected classroom's volume is different. Four classrooms were selected to compare the radon concentration in accordance with the year of completion, Classrooms that is same year of completion were selected to compare the radon concentration in accordance with the volume, six classroom was performed closure and ventilation to compare radon concentration according to ventilation. Radon concentrations in accordance with the year of building completion showed a high concentration of radon in a building recently built. Also, Radon concentration in volume is high the smaller the volume. Radon concentration change according to ventilation showed a reduction of about 80% when the ventilation than during closing. Especially, The radon concentrations were high detected while the recently year of building completion and the smaller volume. Ventilation of the three variables is considered that can be expected to exposure reduction effect by radon affecting the greatest radon concentration reduction

  4. High indoor radon concentrations in some Swedish waterworks

    International Nuclear Information System (INIS)

    Aakerblom, G.; Hagberg, N.; Mjoenes, L.; Heiberg, A.

    2002-01-01

    High indoor radon concentrations in buildings used for water treatment are not uncommon. When raw water is processed in an open system radon escapes from the water to the indoor air of the premises. It is not unusual that the staff of the waterworks have their offices in the building where the water is processed. If large volumes of water are processed and the evaporated radon can reach the workplaces the indoor radon concentration can be very high even if the radon concentration of the raw water is moderate. Groundwaters from aquifers in bedrock and soil and surface water that has been infiltrated through deposits of sand or gravel have the potential to cause high indoor radon levels. In surface water emanating directly from a lake or a river the radon concentrations are normally too low to cause problems. Three waterworks in central Sweden have been studied, Ludvika, Fredriksberg and Kolbaeck. The radon concentrations in the raw water of these waterworks are from 85 Bq/l to 300 Bq/l. Average indoor radon concentrations exceeding 17,000 Bq/m 3 have been measured in Ludvika with peaks of almost 37,000 Bq/m 3 . In Kolbaeck radon concentrations up to 56,000 Bq/m 3 have been measured. It is quite possible that employees of waterworks can receive doses exceeding 20 mSv per year (calculated according to ICRP:s dose conversion convention). Measurements of radon and gamma radiation from the waterworks are reported and methods to lower the indoor radon concentrations are discussed. (author)

  5. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  6. Effect of fresh air ventilation on indoor radon concentration

    International Nuclear Information System (INIS)

    Sun Hao; Wu Jianhua; Fu Shi

    2012-01-01

    The radon concentration of laboratory for radon simulation (LRS) was measured by the RAD7 radon monitor, and the effect of the different fresh air ventilations on indoor radon concentration was studied and analyzed. The indoor radon concentration of LRS can be accumulated up to 2000 Bq/m 3 and the average radon exhalation rate of the LRS is 14.5 Bq · m -2 . h -1 . Furthermore, when the fresh air enters into the LRS continuously, the indoor radon concentration decreases exponentially with the increase of time. The equilibrium radon concentration and equilibrium time of LRS decrease exponentially with the increase of the rate of fresh air ventilation. In addition, the indoor radon concentration increases by accumulation with the decrease of the rate of fresh air ventilation. (authors)

  7. Radioactivity in the furnace air-cleaning filter from a house with an unusually high level of airborne radon

    International Nuclear Information System (INIS)

    Rundo, J.; Essling, M.A.; Urnezis, P.W.

    1979-01-01

    The amounts of the three short-lived daughters of radon on the furnace air-cleaning filter from a house with a high level of radon were estimated to be 8.2, 33, and 38 kBq (0.22, 0.89, and 1.03 μCi) for 218 Po, 214 Pb, and 214 Bi, respectively, at the time of removal from the furnace. These data were used to calculate the airborne concentrations of the three, and the results indicated that about 70% of the daughters were lost to surfaces in the house and by impaction in the air ducts. The filter's content of 210 Pb was found to be 4.4 kBg (0.12 μCi); from this the average concentration of radon-producing filterable daughters during the time the furnace blower operated, was estimated to be 860 Bq m -3 . This indicated that there was no significant loss to surfaces or in air ducts. Possible reasons for the difference are given. The filter was also found to contain 1 kBq (27 nCi) of 212 Bi from the thorium series

  8. An investigation of factors influencing indoor radon concentrations

    International Nuclear Information System (INIS)

    Majborn, B.; Soerensen, A.; Nielsen, S.P.; Boetter-Jensen, L.

    1988-05-01

    Variations in indoor radon concentrations and some influencing factors have been studied during a two-year period (1986-1987) in 16 almost identical single-family houses.The annual average radon concentration in the houses varied from about 50 to about 400 Bq/m 3 . Variations in soil characteristics and radon concentration in soil gas could not be directly related to the variations of the average indoor radon concentrations. Most of the houses showed a ''normal'' seasonal variation of the radon concentration with a maximum in the winter and minimum in the summer. A deviating seasonal variation was found in three of the houses. Hourly data obtained in one unoccupied house during a period of 2-1/2 months showed no or only weak correlations between the indoor radon concentration and meteorological factors. However, for most of the houses, the seasonal variation of the indoor radon concentration was well correlated with the average indoor-outdoor temperature difference on a 2-month basis. It was demonstrated that the radon concentration can be strongly reduced in the Risoe houses if a district-heating duct, which is connected to all the houses, is ventilated, so that a slightly lowered pressure is maintained in the duct. 5 taps., 24 ill. (author)

  9. Modeled atmospheric radon concentrations from uranium mines

    Energy Technology Data Exchange (ETDEWEB)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs.

  10. Modeled atmospheric radon concentrations from uranium mines

    International Nuclear Information System (INIS)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs

  11. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    International Nuclear Information System (INIS)

    Momeni, M.H.; Lindstrom, J.B.; Dungey, C.E.; Kisieleski, W.E.

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m 3 on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m 3 . Average working-level background is 3.6 x 10 -3

  12. Radon concentration in a house of Calvados

    International Nuclear Information System (INIS)

    Leleyter, L.; Riffault, B.; Mazenc, B.

    2010-01-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados (Normandy region). Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home. (authors)

  13. Radon concentration distribution mapping in a small detached house

    International Nuclear Information System (INIS)

    Muellerova, Monika; Moravcsik, Attila; Holy, Karol; Hutka, Miroslav; Hola, Olga

    2013-01-01

    Radon activity concentration was investigated in an older, single storey detached house. The rooms of the house are in contact with the bedrock. The house is fitted with plastic windows and populated mostly during the summer. Integral (Raduet) and continuous (AlphaGUARD) methods were used to measure the radon activity concentration. Average radon and thoron activity concentrations in the house were 150 Bq/m 3 and 40 Bq/m 3 , respectively. The impact of the house occupancy on radon activity concentration was significant only during the summer months when a decrease of radon activity concentration was recorded due to an increased ventilation rate. In the autumn and winter months, the impact of the house occupancy on radon activity concentration was relatively small - up to 20 %. The increases in radon activity concentration after the room had been thoroughly ventilated were analysed in order to estimate the ventilation rate and the rate of radon supply into the house. (orig.)

  14. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  15. The effect and the amendment of thermoregulation to the stability of radon concentration in radon chamber

    International Nuclear Information System (INIS)

    Zhang Xiongjie; Wang Renbo; Qu Jinhui; Tang Bin; Zhu Zhifu; Man Zaigang

    2010-01-01

    When the temperature in the airtight radon chamber was adjusted, it would induce the frequent changes of the air pressure in chamber, then the radon concentration in the radon chamber would continuously reduce, which could seriously destroy the stability of the radon concentration in radon chamber. In this paper, on the study of the effect reasons to the stability of radon concentration in airtight radon chamber due to the thermoregulation, a new amendment scheme was put forward, and the solutions of the relevant parameters were discussed. The amendment scheme had been successfully applied to HD-6 radon chamber, and achieved good results. (authors)

  16. Radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    Energy Technology Data Exchange (ETDEWEB)

    Momeni, M H; Lindstrom, J B; Dungey, C E; Kisieleski, W E

    1979-11-01

    Radon concentration, working level, and meteorological variables were measured continuously from June 1977 through June 1978 at three stations in the vicinity of the Anaconda Uranium Mill with measurements integrated to hourly intervals. Both radon and daughters show strong variations associated with low wind velocities and stable atmospheric conditions, and diurnal variations associated with thermal inversions. Average radon concentration shows seasonal dependence with highest concentrations observed during fall and winter. Comparison of radon concentrations and working levels between three stations shows strong dependence on wind direction and velocity. Radon concentrations and working-level distributions for each month and each station were analyzed. The average maximum, minimum, and modal concentration and working levels were estimated with observed frequencies. The highest concentration is 11,000 pCi/m/sup 3/ on the tailings. Working-level variations parallel radon variations but lag by less than one hour. The highest working levels were observed at night when conditions of higher secular radioactive equilibrium for radon daughters exist. Background radon concentration was measured at two stations, each located about 25 km from the mill, and the average is 408 pCi/m/sup 3/. Average working-level background is 3.6 x 10/sup -3/.

  17. Radon concentration of waters in Greece and Cyprus

    Science.gov (United States)

    Nikolopoulos, D.; Vogiannis, E.; Louizi, A.

    2009-04-01

    Radon (222Rn) is a radioactive gas generated by the decay of the naturally occurring 238U series. It is considered very important from radiological point of view, since it is the most significant natural source of human radiation exposure (approximately 50% from all natural sources). Radon is present in soil, rocks, building materials and waters. Through diffusion and convection, radon migrates and emanates to the atmosphere. Outdoors, radon concentrates at low levels (in the order of 10 Bq/m3). However indoors, radon accumulates significantly. It is trivial to observe indoor environments with high radon levels (in the order of 400 Bq/m3 or higher). Radon accumulation indoors, depends on the composition of the underlying soil and rock formation, on building materials, meteorological parameters, ventilation, heating and water use. Although soil and building materials are the most significant radon sources, there have been reported elevated radon concentrations in building structures due to entering water. It is the radon concentrations in the entering water, the volume and the way of water usage, separated or in combination, that result in large amounts of radon in indoor air. Moreover, radon is a factor of stomach radiation burden due to water consumption. This burden is estimated by measurements of radon concentrations in waters. Due to the health impact of radon exposure, the reporting team continuously measures radon. This work focused on the radon concentrations exposure due to water consumption and use in Greece and Cyprus. Various locations in Greece and Cyprus were accessed taking into consideration existing natural radioactivity data (mainly radon in water), however under the restriction of the capability of movement. Radon in water was measured by Alpha Guard (Genitron Ltd) via a special unit (Aqua Kit). This unit consists of a vessel used for forced degassing of radon diluted in water samples, a security vessel used for water drop deposition. Vessels and

  18. Measurement of radon concentration in water by means of {alpha}, {gamma} spectrometry. Radon concentration in ground and spring water in Hiroshima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi [Hiroshima Univ. (Japan)

    1997-02-01

    Radon ({sup 222}Rn, T{sub 1/2}=3.8235{+-}0.0003d) is {alpha}-ray releasing nuclide, so that it can not be detected by {gamma}-ray measurement. But, the daughter nuclides {sup 214}Pb (T{sub 1/2}=26.8 min) and {sup 214}Bi (T{sub 1/2}=19.9 min) release {gamma}-ray, accordingly they are measured by Ge detector. Their radioactive equilibrium is kept in the closed vessel, because their half-lives are shorter than that of radon. We developed a measurement method of radon concentration by means of {gamma}-spectrometry. We applied this method to catch radon in the atmosphere by active carbon. The same principle can be applied to radon in water. Radon concentrations in the ground water were measured in 22 points in the Higashi-Hiroshima city and 82 points in the Hiroshima prefecture. The efficiencies of {gamma}-ray were determined. The radon concentration showed between 11 and 459 Bq/l and the average was 123 Bq/l. The high concentration of radon was distributed in the spring of granitic layer and higher concentration of radon were observed in the ground water of fault. (S.Y.)

  19. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  20. Design Criteria for Achieving Low Radon Concentration Indoors

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving low radon concentration indoors are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most...... countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. Three criteria when used can prevent radon infiltration and lower...... the radon concentration in the indoor air. In addition, a cheap and reliable method for measuring the radon concentration in the air indoors is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause...

  1. Removal of radon daughters from indoor air

    International Nuclear Information System (INIS)

    Jonassen, N.

    1985-01-01

    The internal radiological exposure of the general population is largely due to the airborne daughter products of radon and thoron, which are found in two states, attached to aerosols or unattached, of which the latter species according to several dose models have the highest radiological dose efficiency of the two. The radon daughters may be removed from indoor air by a series of processes like ventilation, filtration, plateout, and electrostatic deposition. Ventilation (with radon-free air) is, on the one hand, a very effective measure, but usually involves introduction of colder air, in variance with energy-saving efforts. Internal filtration will not affect the radon concentration but may reduce the level of daughter activities, roughly inversely proportional to the filtration rate. At the same time, however, filtration may also change the aerosol distribution and concentration of the air and, consequently, the partitioning of the radon daughters between the attached and unattached state. This, in turn, influences the rate of deposition of radon daughters both by diffusional plateout and as an effect of an electric field. Experiments are reported demonstrating reductions in the airborne potential alpha energy by factors of 4 to 5 by use of filtration rates of 3-4 times per hour. In case of low aerosol concentrations, however, the corresponding reduction in radiological dose to critical parts of the respiratory tract may be much smaller, due to the shift toward higher fractions of the radon daughters being in the unattached state caused by the filtration. The possibility of using electrostatic deposition of radon daughters is also discussed

  2. Measurement of mean radon concentrations in the Tokai districts

    International Nuclear Information System (INIS)

    Iida, Takao; Ikebe, Yukimasa; Yamanishi, Hirokuni

    1989-01-01

    This paper describes an electrostatic integrating radon monitor designed for the environmental radon monitoring and longterm measurements of mean radon concentrations in outdoor and indoor air. The position of the collecting electrode within the monitor was determined based on the calculation of the internal electric field. The radon exchange rate between the monitor and the outside air through the filter was 0.75 h -1 . The exchange rate can make the radon concentration inside the monitor to follow thoroughly the outside concentration. Since the electrostatic collection of RaA + ( 218 Po + ) atoms depends on the humidity of the air, the inside of the monitor was dehumidified with a diphosphorus pentaoxide (P 2 O 5 ) drying agent which is powerful and dose not absorb radon gas. From the relationship between track density and radon exposure, the calibration factor was derived to be 0.52 ± 0.002 tracks cm -2 (Bq m -3 h) -1 . The detection limit of mean radon level is 1.2 Bq m -3 for an exposure time fo 2 months. The mean radon concentrations in various environments were measured through the year using the monitors this developed. The annual mean outdoor radon level in the Tokai districts was 7.0 Bq m -3 . The mean radon concentrations was found to vary from 3.5 to 11.7 Bq m -3 depending upon the geographical conditions even in this relatively small region. The annual indoor radon concentrations at Nagoya and Sapporo ranged from 6.4 to 11.9 Bq m -3 and from 15.5 to 121.1 Bq m -3 , respectively, with the type of building material and the ventilation rate. The mean radon concentrations in tightly built houses selected at Sapporo are about 10 times as high as those in drafty houses at Nagoya. (author)

  3. The use of mechanical ventilation with heat recovery for controlling radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Hollowell, C.D.; Roseme, G.D.

    1980-01-01

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for two weeks under varying ventilation conditions (0.07 to 0.8 air changes per hour (ach)) and radon daughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher radon and radon daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective, and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in houses designed or retrofitted to achieve low infiltration

  4. Concentration variation of radon in the room

    International Nuclear Information System (INIS)

    Komaruzaman Mohd Noor; Haziman Hassan; Rosli Mahat; Yusof Md Amin

    1995-01-01

    The study was carried out to determine the variation of radon concentration in the room. Radon detector used was solid nuclear tracks detector (SSNTD) LR-115. From this result, suitable points to make radon measurement was determined

  5. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  6. Rapid determination of radon daughter concentrations

    International Nuclear Information System (INIS)

    Bigu, J.

    1990-08-01

    A technical evaluation of four radon 222 progeny measuring instruments has been conducted. The evaluation has been carried out under laboratory controlled conditions and at several locations in an underground uranium mine. The laboratory evaluation consisted of a thorough study of the behaviour and performance of the instruments under a wide variety of environmental conditions such as radon 222 gas concentration, radon 222 progeny concentration, temperature, relative humidity, aerosol concentration, and gamma-field exposure. The four instruments tested were: the Pylon WL-1000C, the MDA IWLM-811, the MIMIL IIM, and the EDA WLM-30. The readings of the instruments were compared with a widely accepted radon 222 progeny concentration measuring method, namely, the Thomas-Tsivoglou method. Two variables affected two instruments significantly, namely, under high aerosol concentration conditions, one of the instruments (EDA WLM-30) ceased to operate because of filter loading. The other variable was gamma-field exposure which affected another instrument (MDA-811) adversely. The instruments were rated according to several criteria. The overall best performer was the MIMIL IIM, although other instruments also fared quite well under a variety of experimental conditions

  7. Study of a Greek area with enhanced indoor radon concentrations

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Koukouliou, V.; Kehagia, K.

    2003-01-01

    In this paper the focus is on Arnea Chalkidikis, an area in Greece with granitic geological background and indications of possible elevated radon concentration indoors. Data are reported of indoor radon measurements with etched track detectors and those used for dosimetric estimations. Moreover, data are reported on soil gas and soil radon concentrations in Arnea, as well as radon and uranium concentrations in water samples. From the measured radon concentrations in water samples the contribution to the overall dose has been calculated. For a period of 1 month, indoor radon and progeny activity has also been monitored in the dwelling that has the maximum indoor radon concentration in Greece. This dwelling is in Arnea and the dose delivered to the inhabitants has been calculated. Mean annual effective dose due to indoor radon was 4.5 mSv and about 11% of this was due to the use of water. Mean soil gas concentration and soil radon concentration were (90 ± 30) kBq m -3 (P -3 (P -1 (P<0.05). (author)

  8. Radon concentration in dwellings of Lanzarote (Canary Islands)

    Energy Technology Data Exchange (ETDEWEB)

    Pinza, C.; Armas, J.H. [La Laguna Univ., Tenerife (Spain). Faculty of Medicine; Poffijn, A. [Ghent Rijksuniversiteit (Belgium). Lab. voor Kernfysica

    1997-07-01

    A total of 126 radon passive dosemeters were distributed in 63 dwellings on the island of Lanzarote (Canary Islands) to measure the indoor radon concentration in the period April-June 1994. The mean overall indoor concentration was 50 Bq.m{sup -3} with a standard deviation of 17 Bq.m{sup -3}. Applying the conversion factor for the effective dose, recommended by ICRP 65, this results in a mean effective dose of 0.75 mSv.y{sup -1}. The mean radon concentration in single-family houses proves to be higher at the ground floor than in upper levels. The mean radon concentration obtained in bedrooms is higher than in living-rooms, independently of the floor they are located at. Statistically significant differences in the mean radon concentration have been found depending on the soil permeability (P = 0.001) and building materials used (P 0.0006). (author).

  9. Radon concentration in dwellings of Lanzarote (Canary Islands)

    International Nuclear Information System (INIS)

    Pinza, C.; Armas, J.H.; Poffijn, A.

    1997-01-01

    A total of 126 radon passive dosemeters were distributed in 63 dwellings on the island of Lanzarote (Canary Islands) to measure the indoor radon concentration in the period April-June 1994. The mean overall indoor concentration was 50 Bq.m -3 with a standard deviation of 17 Bq.m -3 . Applying the conversion factor for the effective dose, recommended by ICRP 65, this results in a mean effective dose of 0.75 mSv.y -1 . The mean radon concentration in single-family houses proves to be higher at the ground floor than in upper levels. The mean radon concentration obtained in bedrooms is higher than in living-rooms, independently of the floor they are located at. Statistically significant differences in the mean radon concentration have been found depending on the soil permeability (P = 0.001) and building materials used (P 0.0006). (author)

  10. Indoor radon concentration forecasting in South Tyrol

    International Nuclear Information System (INIS)

    Verdi, L.; Weber, A.; Stoppa, G.

    2004-01-01

    In this paper a modern statistical technique of multivariate analysis is applied to an indoor radon concentration database. Several parameters are more or less significant in determining the radon concentration inside a building. The elaboration of the information available on South Tyrol makes it possible both to identify the statistically significant variables and to build up a statistical model that allows us to forecast the radon concentration in dwellings, when the values of the same variables involved are given. The results confirm the complexity of the phenomenon. (authors)

  11. Concentration en radon dans une maison du Calvados

    Science.gov (United States)

    Leleyter, Lydia; Riffault, Benoit; Mazenc, Bernard

    2010-03-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados. Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home.

  12. Long-term measurement of radon concentration in the family house

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.

    2009-01-01

    The aim of this report was monitored the family house with radon concentration above radon limit for inhabited areas during one year. We were studied radon concentration changes in different rooms this house. Knowledge concerning of variations of radon activity concentration in family house were obtained. Daily variations show a maximum in the morning and a minimum in the afternoon. The seasonal variations show a minimum in spring months (March -April) and a maximum in early autumn (September). The radon concentration in the upstairs room was similar but ten-times lower than radon concentration in the downstairs room. In next period, the obtained results will be analysed in detail and different model describing the behaviour of radon in indoor air will be tested too. (authors)

  13. Unattached radon daughter atoms and radon daughter equilibrium ratios in uranium mines. Final report

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1972-01-01

    Uranium mines in Colorado and New Mexico were surveyed for airborne concentrations of radon (10043922) and radon daughters. A procedure for measuring individual daughters and the fraction of each existing as free atoms was developed and used for field monitoring. Samples were taken in working areas and particle counts were made. The data was analyzed to determine the ratio of radon to radon daughters as well as the ratios among the radon daughters. The author concludes that since the radon to working level ratios have not changed much in 20 years, using the ratio as the basis for estimating relative biological hazard is just as uncertain now as then. The large number of daughters present as free atoms indicate that the lung radiation doses calculated using any of the lung models need reexamination

  14. Diurnal Variation of Radon Concentration in the Postojna Cave

    International Nuclear Information System (INIS)

    Gregoric, A.; Vaupotic, J.

    2011-01-01

    Postojna Cave, with 20 km of galleries, is the longest known cave system and also the largest of about 20 show caves in Slovenia and one of the most visited show caves in the world. It is well known that high concentrations of radon are common in karstic caves, although quantities of uranium (238U) in limestone are rather low. The reason for this is low natural ventilation of the underground cavities. Tectonic faults constitute an additional source of radon. Variations of radon concentration in cave air arise from a balance of the emission from cave surfaces and drip waters, decay in cave air, and exchange with the outside atmosphere. Because of its elevated radon concentrations, Postojna Cave has been under permanent radon survey since 1995. The influence of meteorological conditions on the radon levels and their temporal variations depends mostly on the shape of the cave, and the number and directions of cracks, corridors and fissures connecting the cave rooms with the outside atmosphere. The driving force for air movement in horizontal caves, and thus the inflow of fresh air and release of the cave air to the atmosphere, is the temperature difference between the cave air and outdoors, which causes seasonal pattern of radon concentration in the cave with high levels in summer and low in winter. However, on a daily scale different behaviour of radon can be observed at different locations in the cave. In this paper diurnal variation of radon concentration at two locations is presented and discussed. Postojna Cave is a horizontal cave with a stable yearly temperature around 10 degrees of @C. Continuous measurements of radon concentration were carried out from 2005 to 2010 at two locations along the guided tourist trail. Radon concentration was measured with Radim 5 WP monitors (SMM Company, Prague, Czech Republic) with sampling frequency once an hour. The evaluation of five-year radon monitoring at two sites in the Postojna Cave reveals significant diurnal and

  15. Anomalous radon concentration in a nuclear research facility

    International Nuclear Information System (INIS)

    Balcazar, M.; Pena, P.

    2014-08-01

    Radon monitoring in more than 60 selected points were part of surveillance radiation activities in the nuclear center of Mexico; three major facilities were inspected, the TRIGA Mark III research reactor, the Tandem Van de Graaff Accelerator and the Pelletron electron Accelerator. During a major maintenance activities in the research reactor, the air extraction system was not functioning for more than a month causing of a radon build up exhaled from the massive concrete of the building, reaching concentrations in some places up to 2.1 kb m -3 . The irradiation room at the Tandem Accelerator presented high radon concentrations up to nearly 5 kb m -3 , manly in the trenches were pipes and electric wires are located, the radon source was identified as originated from small caves under the floor. Low radon concentrations were found inside a similar building where a Pelletron accelerator is located. The reasons for the abnormal radon concentrations and the mitigation actions to remove any risk for the worker are discussed in detail in this paper. (author)

  16. Anomalous radon concentration in a nuclear research facility

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, M.; Pena, P., E-mail: miguel.balcazar@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-08-15

    Radon monitoring in more than 60 selected points were part of surveillance radiation activities in the nuclear center of Mexico; three major facilities were inspected, the TRIGA Mark III research reactor, the Tandem Van de Graaff Accelerator and the Pelletron electron Accelerator. During a major maintenance activities in the research reactor, the air extraction system was not functioning for more than a month causing of a radon build up exhaled from the massive concrete of the building, reaching concentrations in some places up to 2.1 kb m{sup -3}. The irradiation room at the Tandem Accelerator presented high radon concentrations up to nearly 5 kb m{sup -3}, manly in the trenches were pipes and electric wires are located, the radon source was identified as originated from small caves under the floor. Low radon concentrations were found inside a similar building where a Pelletron accelerator is located. The reasons for the abnormal radon concentrations and the mitigation actions to remove any risk for the worker are discussed in detail in this paper. (author)

  17. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  18. Radon concentration levels in Fatima Jinnah women university Pakistan

    International Nuclear Information System (INIS)

    Khan, S.A.; Ali, S.; Tufail, A.; Qureshi, A.A.

    2005-01-01

    Public exposure to radioactive gas radon and its progeny present in the air results in the largest contribution to total effective dose received by human beings. It is therefore of great concern to monitor radon concentration in energy conserved air tight buildings. Measurements of radon in the Fatima Jinnah Women University (FJWU) have been carried out for investigation and comparison of radon concentration in the new and old buildings of the campus at Rawalpindi, Pakistan. The study was done because according to the international guidelines concerning environmental problems, it is necessary to evaluate and know the radon levels, especially since most of the natural radiation dose to human beings comes from radon gas and its progeny. Solid State Nuclear Track Detectors (SSNTDs) being efficient, therefore, the measurements were carried out by passive, time integrated method, using CR-39 detector in polythene bags. The detectors were exposed for more than six month in various locations indoors and outdoors. The detectors were etched using NaOH, the tracks were counted manually, and the track density was converted to radon concentration. Radon concentration varied from 31 to 213 Bq.m -3 in old building and from 27 to 143 Bq.m -3 in new buildings, showing slight elevated values in the old buildings. Radon concentration values were found to be less than the values quoted by radiation protection agencies. Radiation dose due to radon varied in the university campus depending on occupancy factor. (author)

  19. Turbidimetry for measurement of radon concentration

    International Nuclear Information System (INIS)

    Wang Huanqiang

    1993-01-01

    This paper describes a turbidimetric technique counting the tracks registered on CR-39 foils exposed to radon. Instead of eyeview through microscope, by using the differential spectrophotometer, strong correlation between the radon cumulative concentration and track turbidence was observed(r=0.999). Under the etching condition of 7.07 mol·L -1 KOH water solution at 80 o C for 16 hr, linear regression showed that the ratio of track turbidence and cumulative concentration of radon exposure was 1.99 x 10 -1 turbidence (KBq m -1 h) -1 and the determination limit was 36 KBq m -3 h. The details of the experiments are represented in this paper. (Author)

  20. Survey of indoor radon concentrations in Fukuoka and Kagoshima prefectures

    International Nuclear Information System (INIS)

    Kunugita, Naoki; Norimura, Toshiyuki; Tsuchiya, Takehiko

    1990-01-01

    It is now well established that radon and its daughter products account for nearly half of the average population exposure to ionizing radiations and that radon is the greatest single source of natural radiation to the population. Radon and its daughters are alpha-emitters, which are more biologically damaging than beta- and gamma-radiations. A nationwide survey of radon concentration was conducted by the National Institute of Radiological Sciences in order to estimate the contribution of radon and its daughters to the population dose in Japan. Authors surveyed indoor radon concentrations in Fukuoka and Kagoshima prefectures as part of this project. A passive type radon dosimeter, in which a sheet of polycarbonate film as the alpha-ray detector was mounted, was used to measure indoor radon concentrations. The resulting distribution of the average annual indoor radon concentrations in both prefectures can be characterized by an arithmetic mean of 24.4 Bq/m 3 and a standard deviation of 13.1 Bq/m 3 , by a geometric mean of 22.2 Bq/m 3 , and by a median of 20.7 Bq/m 3 . The geometric means of the distributions for Fukuoka and Kagoshima were 25.4, and 18.4 Bq/m 3 , respectively. Radon concentrations were also generally high in winter and low in summer. Regarding the analysis of correlations between the concentrations and construction materials, radon concentrations were generally high in Japanese houses with earthen walls and in concrete structures. These results showed that seasons, the type of building materials, and regional differences were significant factors in the variation of indoor radon concentration. (author)

  1. Control of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.

    1986-01-01

    Exposure to radon daughter concentration in indoor atmosphere can result in a significant risk to the general public. There are two generally used methods for the control of radon and progeny concentration in the indoor atmosphere, namely restriction of radon entry and reduction of indoor radon and its progeny concentration by ventilation or by air cleaning. Predominant radon entry process in most of the dwellings appears to be by pressure driven flow of soil gas through cracks or other openings in the basement slab or subfloors. Sealing these openings or ventilation of the subslab or subfloor space are the methods for reducing the radon entry rates. Indoor radon concentration can also be reduced by increasing the ventilation and by using charcoal filters for the removal of radon gas in indoor air by absorption. Concentration of radon progeny, which are responsible for most of the health risks associatd with radon exposure can also be controlled by the use of electrostatic or mechanical filters. This study describes briefly the above control strategies used for reducing the inhalation doses to persons in dwellings. (author). 9 refs., 2 tables

  2. Measurements of radon concentrations at caves in Jeju

    Energy Technology Data Exchange (ETDEWEB)

    Go, S. H.; Kang, D. H.; Jung, B. J. [Cheju National University, Cheju (Korea, Republic of)

    2004-07-01

    Radon is a radioactive gas emitting {alpha} particles. It is chemically stable due to its inert characteristic. While its daughter products, {sup 218}Po, {sup 214}Bi, {sup 214}Pb and {sup 214}Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 {approx} 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m{sup 3}. With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m{sup 3} and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m{sup 3} suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor.

  3. Measurements of radon concentrations at caves in Jeju

    International Nuclear Information System (INIS)

    Go, S. H.; Kang, D. H.; Jung, B. J.

    2004-01-01

    Radon is a radioactive gas emitting α particles. It is chemically stable due to its inert characteristic. While its daughter products, 218 Po, 214 Bi, 214 Pb and 214 Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 ∼ 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m 3 . With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m 3 and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m 3 suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor

  4. Contribution of radon in natural gas to the dose from aiborne radon-daughters in homes

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.

    1973-01-01

    Data have been obtained on the radon concentration in natural gas supplied to several metropolitan areas in the United States. The average value of 20 pCi/l was selected to estimate the contribution of this source of natural radioactivity to doses from radon-daughters received by individuals in homes. Radon-daughter concentrations in the home atmosphere were calculated by use of computer programs for an 8000 ft 3 house in which 27 ft 3 of gas per day was used for cooking in an unvented kitchen range. The total estimated dose to the bronchial epithelium included contributions from radon plus daughters in the outside ventilation air, each of which was assumed to be present at a concentration of 0.13 pCi/l, and from the radon plus daughters in the natural gas. The latter contribution averaged approximately 3 percent of the total dose. There was a 3.5 percent decrease in the estimated total dose when the air change rate increased from 0.25 to 2.0 per hour. We conclude that radon and radon-daughters entering the home with natural gas produce a negligible fraction of the total dose to the respiratory system of home occupants from airborne radon-daughters

  5. Reduction of radon concentration in a basement workplace: study of the problem and characterization of the main parameters affecting the radon concentration

    International Nuclear Information System (INIS)

    Chiaberto, E.M.; Magnoni, M.; Righino, F.; Costa Laia, R.

    2002-01-01

    In this work is described the method used for the mitigation of high radon concentrations found in a basement workplace, the ARPA laboratory used for the metrology of EMF. In this lab was in fact measured a radon concentration up to 1900 Bq/m 3 , a value largely exceeding the Italian limit for workplaces (500 Bq/m 3 ). The basement workplace affected by radon is a room of around 500 m 3 with no windows and only one door, during work usually close, and therefore with a very low ventilation rate. In this workplace, usually two persons spent about 6 hour per day. Therefore their exposure to the radon and its decay products can attain a considerable value. For this people, accordingly to the accepted dosimetric models, an effective dose of several mSv per year could be estimated (ICRP Publication n. 65, 1993). It is thus important to reduce the radon concentration to acceptable levels, i.e. at least lower than 500 Bq/m 3 . This paper deals not only with the simple method used for the remedial action, but also to the investigation of the relevant parameters affecting the radon concentration. In particular, the monitoring of the radon concentration before and after the remedial action, allowed the calculation of the radon entry rates (Bq/s) and the ventilation rates (s-1) in the different experimental condition

  6. Tracing and dealing with dwellings with high radon and radon daughter concentrations

    International Nuclear Information System (INIS)

    Ehdwall, Hans

    1980-01-01

    In the late 1970s it was found that a number of buildings in Sweden, primarily those made from alum shale-based concretes, had elevated radon and radon daughter levels. A special commission investigated the problem and established provisional limiting values for radon daughter exposures, gamma radiation from the ground, and the concentrations of radioactive materials in building materials. With regard to gamma radiation from the ground the commission proposed that no building be built in an area where outside gamma radiation exceeds 100 μR/h. For building materials a gamma index (mγ) and a radium index (mRa) are suggested: mγ = Csub(K)/10000 + Csub(Ra)/1000 + Csub(Th)/700; mRa = Csub(Ra)/200 (Csub(K), Csub(Ra) and Csub(Th) are the concentrations of potassium, radium and thorium respectively). The proposed limiting values are such that the gamma index and the radium index be less than 1. It is also suggested that action should be taken to reduce radon levels in buildings with radon daughter concentrations of 0.27 WL within two years and 0.10 WL within 5 years

  7. Measurements of radon activity concentrations in air at Niska spa

    International Nuclear Information System (INIS)

    Adrovic, F.; Vuckovic, B.; Ninkovic, M.

    2004-01-01

    Radon activity concentrations in air were measured in the recreational-tourist center of Niska Banja. Alpha Guard PQ 2000/ MC50 instrumentation (Genitron instruments, Frankfurt) was used. The observed indoor radon concentrations in the air of the Radon Hotel pool lay within the range of 0.980-1.908 kBq/m 3 and were directly dependent on the exhalation of radon from thermomineral waters. Radon concentrations were also measured outdoors, at locations for capping thermomineral water, as well as at locations for draining used water from the Radon Hotel pool. Outdoor radon concentrations as high as over 500 Bq/m 3 were observed. Gamma dose rates were measured in parallel and found to lie within the range of 72-420 nSv/h. The gamma doses correlated well with the observed radon levels. The largest gamma dose rates in air were measured in the pool of Radon Hotel and at the site where this thermomineral water is being capped

  8. Radon Concentration in Caves of Croatia - Assesing Effective Radon Doses for Occupational Workers and Visitors

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Vukovic, B.; Paar, D.

    2011-01-01

    Radon monitoring at potentially highly radioactive location such as caves is important to assess the radiological hazards to occupational workers and occasional visitors. In its Publication 65 the ICRP has produced recommendations dealing with exposure to elevated background radiation, in particular, the risk associated with the inhalation of radon and radon progeny. Recommended annual effective dose from radon 222Rn and its short-lived progeny for workers should not exceed 20 mSv and for occasional users (visitors) the same recommendation is 1 mSv. Measurements were performed with series of track etched detectors (LR115 - type II) in several caves in Croatia. The obtained values for the radon concentration ranged from ambient values up to several thousand Bq m -3 . Radon concentration was measured in about 20 caves of Velebit and Zumberak mountains and the highest radon concentration was in Lubuska jama (3.8 kBq m -3 ) and cave Dolaca (21.8 kBq m -3 ), respectively. Djurovica cave is especially interesting because of its huge tourist potential due to its location bellow Dubrovnik airport. Its mean annual radon concentration of 17.6 kBq m -3 classifies Djurovica cave among caves with high radon concentration. A visitor during half an hour visit at summer time would receive an effective dose of 30.6 μSv. Calculated mean dose rate of 44 μSv/h means that workers (mainly tourist guides) should limit their time inside cave to 454 hours per year. Manita pec is the only cave open for tourists on the territory of Paklenica National Park. The preliminary radon measurements performed during summer 2010, gave an average radon concentration of 1.1 kBq m -3 . An exposure to average dose rate of 3.7 μSv/h means that the tourist guides would receive an effective dose of 0.42 mSv during summer period according to their working schedule. A visitor during half an hour visits would receive an effective dose of 1.86 μSv. (author)

  9. The effect of filtration on radon daughter atmospheres: Laboratory and field experiments

    International Nuclear Information System (INIS)

    Jonassen, N.; Jensen, B.

    1987-01-01

    Airborne radon daughters may be removed from the air by internal filtration using mechanical or electrofilters. The effect of the filtration may be evaluated in absolute measure by the decrease in the potential alpha energy concentration (or equivalent equilibrium concentration) or relatively by the decrease in the equilibrium factor. The filtration, however, may also change the distribution of airborne radon daughter activity between the unattached and the aerosol-attached state in a way to increase the radiological dose corresponding to a given potential alpha energy concentration. The paper describes a series of laboratory and field experiments which indicate that it is possible by the use of household electrofilters with filtration rates of 2-3 h -1 to lower the radon daughter concentrations to about 20 -30 % and the average radiological dose to about 50-60 % of the value in unfiltered air

  10. Effect of ventilation type on radon concentration at places of work

    International Nuclear Information System (INIS)

    Oksanen, E.

    1994-01-01

    Indoor radon ( 222 Rn) concentrations were measured at 76 child care facilities and 36 schools in southern Finland. The buildings had three different types of ventilation systems: mechanical air supply and exhaust, mechanical exhaust, and natural ventilation, the first being most common. The effect of the ventilation type on the long-term radon concentration was studied in child care facilities. The radon concentrations were highest in the naturally ventilated buildings. The mechanical air supply and exhaust system maintained the lowest values in cold wintertime. In school buildings both the long-term radon concentration and short-term radon and daughter concentrations were measured. The correlation of the ventilation type and the radon concentration was not obvious in this group of measurements, but the radon concentrations and the equilibrium factors were highest in buildings with natural ventilation. Radon concentrations were generally lower during the working hours than during the one-month period, as expected. (author)

  11. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  12. A survey of indoor radon and particular concentration

    International Nuclear Information System (INIS)

    Ohta, Yukiko

    1993-01-01

    Lung disease risk from inhalation of radon can be enhanced by the presence of particular pollutants in indoor air. The indoor concentration of radon and particulates were measured in homes, a department store, and offices in a high building in Tokyo metropolis, as well as in homes in both northern and western Japan. Passive radon monitors were located in living rooms and offices for more than three months at 99 sites during the winter of 1988 and 1989. Indoor radon concentration ranged from 11.1 Bq/m 3 to 148 Bq/m 3 (n=99) and averaged value S.D. was 36.5±14.2 Bq/m 3 . However, the average concentration in air conditional buildings was 21.8±9.51 Bq/m 3 (n=17). Simultaneously at 65 of the radon sites, indoor particulates were collected using personal dust samplers by impaction methods. Deposited particulate concentrations on the sampler were measured and calculated in a unit of μm/m 3 . Concentrations were determined for particle sizes above and below 2.5 μm, for both smoking or non smoking sites. Consequently, concentration of particle size below 2.5 μm was high in smoking rooms. Finally, it was considered that smoking was a complex indoor pollutant as adherence of radon daughter to aerosols. (author)

  13. A nationwide survey of radon concentration in Japan. Indoor, outdoor and workplace

    International Nuclear Information System (INIS)

    Sanada, Tetsuya; Oikawa, Shinji; Kanno, Nobuyuki; Abukawa, Johji; Higuchi, Hideo

    2004-01-01

    The nationwide indoor, outdoor and workplace radon concentrations were surveyed in Japan. These surveys were conducted to estimate the natural radiation dose due to radon and its progeny for the general public. The radon concentration was measured using passive type radon monitor. The number of radon monitors were installed at indoor, outdoor and workplace for 940 houses, 705 points and 705 sites, respectively. The radon concentration was measured for one year at each measurement site. Annual mean radon concentration was obtained from four quarters measurements of 47 prefectures in Japan. The nationwide indoor, outdoor and workplace annual mean radon concentration were 15.5 Bq m -3 , 6.1 Bq m -3 and 20.8 Bq m -3 , respectively. Their radon concentration shows approximately a logarithmic normal distribution. Workplace showed relatively high radon concentration compared with other environments, may be due to construction materials and low ventilation rate. The indoor radon concentration found to be seasonal variation and architectural dependences. Seasonal variation and regional distribution of outdoor radon concentration was also observed. From the results of these radon surveys, the annual effective dose to the general public due to radon and its progeny was estimated to be 0.49 mSv y -1 in Japan. (author)

  14. Radon remediation of a two-storey UK dwelling by active sub-slab depressurization: observations on hourly Radon concentration variations

    International Nuclear Information System (INIS)

    Denman, A.R.

    2008-01-01

    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored at hourly intervals throughout a 5-week period during which sub-slab depressurization remediation measures, including an active sump system, were installed. Remediation of the property was accomplished successfully, with the mean radon levels upstairs and downstairs greatly reduced and the prominent diurnal variability in radon levels present prior to remediation almost completely removed. Following remediation, upstairs and downstairs radon concentrations were 32% and 16% of their pre-remediation values respectively. The mean downstairs radon concentration was lower than that upstairs, with pre-and post-remediation values of the upstairs/downstairs concentration ratio, R U/D , of 0.93 and 1.76 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 hour or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure-difference prior to remediation. This correlation disappears following remediation, confirming the effectiveness of the remediation procedure in mitigating radon ingress from the ground via the stack-effect. Overall, these observations provide further evidence that radon emanation from building materials makes a not insignificant contribution to radon concentration levels within the building. Furthermore, since this component remains essentially unaffected by sub-slab depressurization, its proportional contribution to the total radon levels in the home increases following remediation, leading to the conclusion that where

  15. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  16. Radon concentrations in different types of dwellings in Israel

    International Nuclear Information System (INIS)

    Epstein, L.; Koch, J.; Riemer, T.; Haquin, G.; Orion, I.

    2014-01-01

    The average radon concentration in Israeli dwellings was assessed by combining the results of a 2006 radon survey in single family houses with the results of a 2011 radon survey in apartments of multi-storey buildings. Both surveys were based on long-term measurements using CR-39 detectors. The survey in multi-storey buildings was intended to assess the influence of recent practices in the local building industry on the radon concentrations. These practices include the use of building materials with higher concentrations of the natural radionuclides in the last 20 y than before, as well as the improvement in sealing techniques over that period. Another practice in place since the early 1990's is the building of a shielded area in every apartment that is known as an RSS (residential secure space). The RSS is a room built from massive concrete walls, floor and ceiling that can be hermetically sealed and is intended to protect its residents from a missile attack. The influence of the above-mentioned features on radon concentrations was estimated by dividing the participating apartments into two groups: apartments in buildings >20 y, built using building materials with low concentrations of the natural radionuclides, regular sealing and without an RSS and apartments in buildings newer than 10 y, built using building materials with higher concentrations of the natural radionuclides, improved sealing and including an RSS. It was found that the average radon concentration in apartments in new buildings was significantly higher than in old buildings and the average radon concentration in single-family houses was significantly higher than in apartments in multi-storey buildings. Doses due to indoor radon were estimated on the basis of the updated information included in the 2009 International Commission on Radiological Protection statement on radon. (authors)

  17. Radon concentrations in well water in Sichuan Province, China

    International Nuclear Information System (INIS)

    Chen Yibin; Wu Qun; Zhang Bo; Chen Daifu

    1998-01-01

    There are 110 million people in Sichuan Province, China. Although most of the people in cities of Sichuan use river water, which contains low levels of radon, as potable water, people in countryside and in some communities of big cities still use well water as domestic consumption. This paper reports the radon concentrations in well water investigated in four cities, i.e. Chengdu, Chongqing, Leshan and Leijiang in Sichuan Province. Of the 80 wells investigated, the radon concentrations range from 3.5 to 181.6 KBqm -3 . Of the four cities, Chongqing has the highest well water radon concentration with the average 49.6 ± 54.1 KBqm -3 and the greatest variation. The investigation in four cities showed that the radon concentrations in well water are much higher than that in tap-water. In Chongqing where there are complex geological structures, mainly granite stratum, for example, the average radon concentration in well water is 112 times higher than that in the tap-water, and even much higher than that in river water in Yangtse River, Jialing River, Jinsha River and Mingjiang River. The population in four cities is about one sixth of the total population in Sichuan Province. Because of the common use of well water and the high radon concentrations in well water in Sichuan Province, the health effect of radon in well water to the public should be stressed. (author)

  18. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989-2013.

    Science.gov (United States)

    Casey, Joan A; Ogburn, Elizabeth L; Rasmussen, Sara G; Irving, Jennifer K; Pollak, Jonathan; Locke, Paul A; Schwartz, Brian S

    2015-11-01

    Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). We evaluated predictors of indoor radon concentrations. Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167-679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52-178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = -0.323, 95% CI: -0.333, -0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989-2013. Environ Health Perspect 123:1130-1137; http://dx.doi.org/10.1289/ehp.1409014.

  19. Investigation on residential radon concentration in Jingchuan county

    International Nuclear Information System (INIS)

    Zhang Wei; Wan Yihong; Chen Hongxiao; Shang Bin

    2009-01-01

    This paper reports an investigated result of residential radon concentration in Jingchuan County, Gansu Province, during May 2004 to November 2006. Alpha track detectors were used to measure radon level. Construction types of house and percentages of residents living in the county were also investigated through questionnaires. The result showed that the mean radon concentration in 62 investigated houses was 96.2 Bq·m -3 . The radon concentration in cave dwelling was the highest among all type of dwellings. The average level in cave dwelling is 110.2 Bq·m -3 , which was significantly higher than the national mean value published in literatures, and exceed the WHO recommended value of 100 Bq·m -3 . A considerable number of rural residents are living in cave dwellings in Jingchuan County. Attention should be paid to the radon problem and some proper protection measures taken. (authors)

  20. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  1. Survey of radon concentrations in three Italian towns

    International Nuclear Information System (INIS)

    Malanca, A.; Pessina, V.; Dallara, G.

    1992-01-01

    Radon-222 was measured in 187 dwellings in Parma, Reggio Emilia, and Orvieto. Samples were collected using activated carbon canisters, placed in basements and on the upper floors for at least 48 h in the period starting from January 1989 to July 1990. Gamma spectroscopy was used for the measurement of 222 Rn and its progeny. The data for the three towns show a lognormal distribution. Owing to the high radium concentration in building materials and underlying soil, high radon concentrations were observed in Orvieto's dwellings. Additional measurements carried out in 22 public schools of Parma and Reggio Emilia showed moderate radon concentrations, while significant radon levels were recorded in 37 castles and ancient buildings in Parma and Reggio Emilia provinces

  2. Relationship between indoor radon concentrations and air exchange rate

    International Nuclear Information System (INIS)

    Wang Jingshu; Liu Yuyu; Yao Xiaohua; Meng Jianfeng; Zhang Yongyi; Wang Xiaohe; Yu Xiufen.

    1995-01-01

    The indoor concentration of radon and the air exchange rate were simultaneously measured in four empty rooms, made of brick and cement, which were located in different floors of dwelling houses in Taiyuan, Shanxi, China. SF 6 tracer gas decay method was used to measure the air exchange rate. Indoor radon was collected with the dimembrane method. When the ventilation rate increased, the concentration of radon dropped rapidly. Regression analysis indicated that the indoor concentration of radon was equal to the outdoor level of radon when the air exchange rate was greater than 3-4. SF 6 decay method was an effective and convenient method for measuring the air exchange rate. There was no marked difference in measurements obtained in different locations of a room. (N.K.)

  3. Radon concentration measurements in the desert caves of Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Mustafa, Hanan [Women College, P. O. Box 838, Dammam 31113 (Saudi Arabia); Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco P.O. Box 13027, Dhahran 31311 (Saudi Arabia)

    2005-11-15

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides.

  4. Radon concentration measurements in the desert caves of Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Mustafa, Hanan; Al-Jarallah, M.I.; Fazal-ur-Rehman; Abu-Jarad, F.

    2005-01-01

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm -3 . The average radon concentration in four of the caves was low in the range 74-114Bqm -3 . However, one cave showed an average radon concentration of 451Bqm -3 . Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides

  5. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  6. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  7. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  8. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  9. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  10. Environmental Concentration of Radon and Radon Progeny in a Nuclear Facility in a Decommissioning Stage

    International Nuclear Information System (INIS)

    Ramirez, M. P.; Correa, E.; Sancho, C.

    1999-01-01

    According to the new European Directive 96/29/EURATOM the radiological risk due to natural radionuclides must be consider and the pertinent periodic control must be realized. During the works performed at CIEMAT an estimation of the effective average doses due to Radon inhalation in work places of the installation have been performed. Radon and Radon progeny concentration has been measured in continuous joint whit the meteorological conditions as temperature, pressure and relative humidity. Two different equipment has been used: Alpha-guard whit ionization chamber detector and Eda-wlm-300 whit a semiconductor detector. A passive Radon detector, E-perm has been simultaneously used in the monitoring system. The results obtained during the measuring of Radon and Radon progeny concentrations indoors and estimation of doses have been analyzed and are presented in the paper. (Author) 11 refs

  11. How to Ensure Low Radon Concentrations in Indoor Environments

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Wraber, Ida Kristina

    2011-01-01

    This paper focuses on methods for measuring radon levels in the indoor air in buildings as well as on concrete solutions that can be carried out in the building to prevent radon leakage and to lower the radon concentration in the indoor air of new buildings. The radon provision in the new Danish...... Building Regulations from 2010 has been tightened as a result of new recommendations from the World Health Organization. Radon can cause lung cancer and it is not known whether there is a lower limit for its harmfulness. It is therefore important to reduce the radon concentration as much as possible in new...... buildings. The airtightness is a major factor when dealing with radon in buildings. Above the ground it is important to build airtight in compliance with energy requirements and against the ground it is important to prevent radon from seeping into the building. There is a direct connection between...

  12. Uranium in soil and gamma dose rate as proxies for the indoor radon risk: situation in Belgium

    International Nuclear Information System (INIS)

    Tondeur, F.; Cinelli, G.; Dehandschutter, B.

    2017-01-01

    Radon risk maps are usually based either on indoor radon data, or on measurements of soil gas radon and soil permeability. If these data are not available or not sufficient, it was suggested that other data could be used as an approximate substitute (a proxy) to the missing information, like the concentration of 238 U or 226 Ra in soils or the terrestrial gamma dose rate (TGDR). We examine here the correlation between airborne measurements of soil U and indoor radon, and between airborne U and TGDR, and their link with affected/unaffected areas. No clear correlation is found between airborne U and affected areas, as strongly affected areas are not characterised by a higher U level. Only the moderately affected area of Condroz can be connected to a higher U level, related to a few U anomalies. TGDR shows a rather good correlation with airborne U, but its relation with radon risk is less clear. Soil uranium and TGDR may help to screen out areas with very low U and very low TGDR, which have a low indoor radon risk, but they cannot be considered as good proxies for predicting radon-affected areas in Belgium. (authors)

  13. Radon and radon daughters' concentration in spring and wells waters from Presidente Prudente: preliminary results

    International Nuclear Information System (INIS)

    Osorio, Ana Maria Araya; Saenz, Carlos Alberto Tello; Pereira, Luiz Augusto Stuani

    2009-01-01

    This work presents the preliminary results about the concentration of radon and radon daughters in wells and springs water from Presidente Prudente. Six water samples were studied: three from well-water, two from springs water and one from potable water. For the determination of α-activity the samples were placed inside plastic containers where the CR-39 tracks detectors were outside the water. The track density of α-particles were measured by using optical microscopy. The results show that one sample from well-water presented higher concentration of radon and radon daughters than the other samples. (author)

  14. Dependence of indoor radon concentration on the year of house construction

    International Nuclear Information System (INIS)

    Fujimoto, K.; Sanada, T.

    1999-01-01

    The dependence of indoor radon concentration on the year of house construction was studied using the results of two nationwide indoor radon surveys in Japan. The data of radon concentration in the surveys were classified into structure type as well as year of construction to obtain the current radon concentration for each structure type as a function of year of construction. The indoor radon concentration in wooden houses was found to be relatively constant with year of house construction until 1960, and then decreased, whereas the radon concentration in concrete houses increased sharply in houses constructed after 1970. The concentration in concrete houses built before 1975 was almost the same as that in contemporary wooden houses. However, the concentration in concrete houses built at present was about two times higher than that in wooden houses. The time trends found for wooden and concrete houses in the first nationwide indoor radon survey were confirmed by the second nationwide survey. In addition, these same time trends were mostly observed in the data classified into 7 districts in Japan. The increase of indoor radon concentration in concrete houses provides relatively high dose, and this increasing trend seems to continue, judging from the results of two nationwide surveys

  15. Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Mujahid, S. A.; Hussain, S.; Ramzan, M.

    2010-01-01

    Plastic track detectors were used to measure the radon concentration and exhalation rate from the soil samples. The samples were collected from areas of southern Punjab (Pakistan). In a laboratory experiment, passive alpha dosemeters were installed inside cylindrical bottles containing the soil samples. The radon concentrations and the radon exhalation rate were found in the ranges of 34±7 to 260±42 Bq m -3 and 38±8 to 288±46 mBq m -2 h -1 , respectively. The on-site measurements of radon in the soil gas were also carried out in these areas using a scintillation alpha counter. The concentration of radon in the soil gas was found in the range of 423±82-3565±438 Bq m -3 . (authors)

  16. Investigation of radon and thoron concentrations in a landmark skyscraper in Tokyo

    International Nuclear Information System (INIS)

    Kazumasa Inoue; Masahiro Fukushi

    2013-01-01

    The temporal variation of the radon concentration, and the radon and thoron concentrations every 3 months for a year were measured using two types of devices in a landmark skyscraper, the Tokyo Metropolitan Government Daiichi Building. In the measurement of temporal variation of the radon concentration using a pulse type ionization chamber, the average radon concentration was 21 ± 13 Bq m -3 (2-68 Bq m -3 ). The measured indoor radon concentration had a strong relationship with the operation of the mechanical ventilation system and the activities of the office workers. The radon concentration also increased together with temperature. Other environmental parameters, such as air pressure and relative humidity, were not related to the radon concentration. In the long-term measurements using a passive radon and thoron discriminative monitor, no seasonal variation was observed. The annual average concentrations of radon and thoron were 16 ± 8 and 16 ± 7 Bq m -3 , respectively. There was also no relationship between the two concentrations. The annual average effective dose for office workers in this skyscraper was estimated to be 0.08 mSv y -1 for 2000 working hours per year. When considering the indoor radon exposure received from their residential dwellings using the annual mean radon concentration indoors in Japan (15.5 Bq m -3 ), the annual average effective dose was estimated to be 0.37 mSv y -1 . This value was 31 % of the worldwide average annual effective dose. (author)

  17. The use of an empirical correlation between surface activity and integrated radon exposure in a retrospective radon measurement

    International Nuclear Information System (INIS)

    Cauwels, P.; Poffijn, A.

    1998-01-01

    Retrospective measurements of integrated radon concentration in dwellings over the past decades are dealt with, based on the fact that glass sheets act as a memory for the airborne radon activity due to the implanted 210 Po and 210 Bi activity. The room model established to this purpose by Jacobi in 1972 seems to need some modifications; calculated and measured data suggest the existence of a possible loss of implanted daughter products. (A.K.)

  18. Results of the radon concentration survey in Sibiu county underground water

    International Nuclear Information System (INIS)

    Chicea, Dan; Cosma, Constantin

    2002-01-01

    In November 2000 a survey of radon ( 222 Rn) concentration in Sibiu county underground water was conducted. The radon concentration was measured with a A LUK 3A. The radon gas was extracted from water using the LUK VR device that works with LUK 3A. All samples were taken in 0.5 l recipients that were filled and sealed. Samples from eighteen cities and villages were taken. Special care was taken for the samples to be carefully brought to room temperature and not to be agitated or stirred before measuring the radon concentration. In measuring the radon concentration corrections like the solubility coefficient variation with temperature, the radon concentration increase in air in time and the background correction were applied. Results reveal that the underground water radon concentration is bigger in wells located in mountainous area, has an average value in wells from hilly region and is considerable lower in wells located in plain area. Another thing we noticed is that the samples taken from the city water pipe system present lower radon concentration values than the samples taken from home drilled wells. The minimum radon concentration value was found in the drinking water of Sibiu city, 1.6 Bq/l and in Sadu village, 1.965 Bq/l. The highest measured values are 28.1 Bq/l in Rasinari, a village located at the bottom of the mountains and 26.4 Bq/l, in Sibiel, a village 30 km away from the first one. These results reveal that the radon concentration values measured in Sibiu county are comparable with the measured values reported in literature and well below the maximum acceptable values. (authors)

  19. An electrical circuit model for simulation of indoor radon concentration.

    Science.gov (United States)

    Musavi Nasab, S M; Negarestani, A

    2013-01-01

    In this study, a new model based on electric circuit theory was introduced to simulate the behaviour of indoor radon concentration. In this model, a voltage source simulates radon generation in walls, conductivity simulates migration through walls and voltage across a capacitor simulates radon concentration in a room. This simulation considers migration of radon through walls by diffusion mechanism in one-dimensional geometry. Data reported in a typical Greek house were employed to examine the application of this technique of simulation to the behaviour of radon.

  20. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  1. Indoor radon measurements in dwellings of Garhwal Himalaya, Northern India

    International Nuclear Information System (INIS)

    Ramola, R.C.

    1996-01-01

    Measurement of indoor radon and daughters concentration were performed in several houses in Garhwal Himalaya during 1993-95 with solid state nuclear track detector films (LR-115 Type II). The detector films were exposed for a period of three month to one year. The films basically measured total airborne alpha activity but may be calibrated in unite of EEC RN (equilibrium equivalent concentration of radon with equilibrium factor F=0.45) in an environment with known radon and daughters concentrations. A numbers of dwelling in the area exhibited radon daughters concentrations (EEC RN ) exceeding the recommended level. The abnormal values are due to typical house construction (mud house) in the area. The houses are constructed with soil and local stone with a thin paste of mud. Behaviour and abnormality of radon in mud houses are discussed in details the corresponding annual effective dose has been calculated. (author)

  2. Distribution of indoor radon concentrations and uranium-bearing rocks in Texas

    International Nuclear Information System (INIS)

    Hudak, P.F.

    1996-01-01

    The purpose of this study was to compare regional patterns of indoor radon concentration with uranium-bearing rock zones and county populations in Texas. Zones yielding radon concentrations that are relatively high for Texas include shale and sandstone in northwest Texas; red beds in north-central Texas; felsic volcanic rocks in west Texas; and sandstone, limestone, and igneous rocks in central Texas. Located in northwest Tecas, only five of the 202 counties evaluated have mean indoor radon concentrations above 4.0 pCi l -1 . Two of those counties have populations above the state median of 20115. The highest county mean concentration is 8.8 pCi l -1 . Results of the study suggest that (1) regional geology influences indoor radon concentrations in Texas, (2) statewide, the radon concentrations are relatively low, (3) highly populated counties do not coincide with regions of high indoor radon concentration, and (4) regions that may warrant further monitoring include northwest Texas and, to a lesser degree, west and central Texas. (orig.)

  3. Characterization of radon entry rates and indoor concentrations in underground structures

    International Nuclear Information System (INIS)

    Borak, T.B.; Whicker, F.W.; Fraley, L.; Gadd, M.S.; Ibrahim, S.A.; Monette, F.A.; Morris, R.; Ward, D.C.

    1992-01-01

    An experimental facility has been designed to comprehensively determine the influence of soil and meterological conditions on the transport of radon into underground structures. Two identical basements are equipped to continuously monitor pressure differentials, temperatures, soil moisture, precipitation, barometric pressure, wind speed, wind direction, natural ventiliation rates, and radon concentrations. A computerized data acquisition system accumulates and processes data at the rate of 6000 points per day. The experimental design is based on performing experiments in one structure, with the other used as a control. Indoor radon concentrations have temporal variations ranging from 150 to 1400 Bq m -3 . The corresponding entry rate of radon ranges from 300 to 10,000 Bq h -1 . When the radon entry rate is high, the indoor radon concentration decreases, whereas elevated radon concentrations seem to be associated with slow but persistent radon entry rates. This inverse relationship is partially due to compensation from enhanced natural ventilation during periods when the radon entry rate is high. Correlations between measured variables in the soil and indoor-outdoor atmospheres are used to interpret these data. This laboratory has the capability to generate essential data required for developing and testing radon transport models

  4. Detection of radon products in atmosphere and its concentration

    International Nuclear Information System (INIS)

    Al-Naemi, H.M.

    1993-01-01

    The climate of the State of Qatar is very warm during the summer and also for considerable parts of the spring and autumn. Energy-tight houses and buildings with air conditioning working day and night for several months are very common. Consequently, the problem of accumulation of indoor radon may exist. No measurements of radon concentration in Qatar have been performed before. The aim of the present work is to implement a suitable technique to measure radon concentration in Qatari houses and buildings. As a first stage, it was found reasonable to start with a technique to evaluate the short-term average indoor radon concentration. The activated charcoal method was chosen to perform this evaluation

  5. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  6. Seasonal variation of radon concentrations in UK homes

    International Nuclear Information System (INIS)

    Miles, J C H; Howarth, C B; Hunter, N

    2012-01-01

    The patterns of seasonal variation of radon concentrations were measured in 91 homes in five regions of the UK over a period of two years. The results showed that there was no significant difference between the regions in the pattern or magnitude of seasonal variation in radon concentrations. The arithmetic mean variation was found to be close to that found previously in the UK national survey. Differences in the pattern between the two years of the study were not significant. Two-thirds of homes in the study followed the expected pattern of high radon in the winter and low radon in the summer. Most of the rest showed little seasonal variation, and a few showed a reversed seasonal pattern. The study does not provide any clear evidence for the recorded house characteristics having an effect on the seasonal variation in radon concentrations in UK homes, though the statistical power for determining such effects is limited in this study. The magnitude of the seasonal variation varied widely between homes. Analysis of the individual results from the homes showed that because of the wide variation in the amount of seasonal variation, applying seasonal correction factors to the results of three-month measurements can yield only relatively small improvements in the accuracy of estimates of annual mean concentrations.

  7. Variance of indoor radon concentration: Major influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Yarmoshenko, I., E-mail: ivy@ecko.uran.ru [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Vasilyev, A.; Malinovsky, G. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Bossew, P. [German Federal Office for Radiation Protection (BfS), Berlin (Germany); Žunić, Z.S. [Institute of Nuclear Sciences “Vinca”, University of Belgrade (Serbia); Onischenko, A.; Zhukovsky, M. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation)

    2016-01-15

    Variance of radon concentration in dwelling atmosphere is analysed with regard to geogenic and anthropogenic influencing factors. Analysis includes review of 81 national and regional indoor radon surveys with varying sampling pattern, sample size and duration of measurements and detailed consideration of two regional surveys (Sverdlovsk oblast, Russia and Niška Banja, Serbia). The analysis of the geometric standard deviation revealed that main factors influencing the dispersion of indoor radon concentration over the territory are as follows: area of territory, sample size, characteristics of measurements technique, the radon geogenic potential, building construction characteristics and living habits. As shown for Sverdlovsk oblast and Niška Banja town the dispersion as quantified by GSD is reduced by restricting to certain levels of control factors. Application of the developed approach to characterization of the world population radon exposure is discussed. - Highlights: • Influence of lithosphere and anthroposphere on variance of indoor radon is found. • Level-by-level analysis reduces GSD by a factor of 1.9. • Worldwide GSD is underestimated.

  8. Radon concentration variations between and within buildings of a research institute

    International Nuclear Information System (INIS)

    Antignani, S.; Bochicchio, F.; Ampollini, M.; Venoso, G.; Bruni, B.; Innamorati, S.; Malaguti, L.; Stefano, A.

    2009-01-01

    Radon concentration in indoor air has been measured in many countries in a large number of buildings - mainly in houses but also in apartments and workplaces - mostly as a result of the application of radon policies and regulation requirements. However, few systematic analyses are available on radon concentration variations within buildings and between close buildings, especially as regards workplaces; such variations can have a significant impact on indoor radon exposure evaluation, and ultimately on the assessment of the dose from radon received by workers. Therefore, a project was started in 2006 aimed to study the spatial variation of radon concentration among and within about 40 buildings of the Istituto Superiore di Sanita (ISS), a research institute of public health located in Rome over a small area of less than 1 km 2 . Nuclear track detectors (CR-39) were used to measure radon concentration for two consecutive six-month periods, in more than 700 rooms of the surveyed buildings. The paper describes the project in detail and preliminary results regarding 558 rooms in 29 buildings. Coefficient of variation (CV) was calculated as a measure of relative variation of radon concentration between buildings, between floors, and between rooms on the same floor. The CV between buildings resulted quite high (88%), a lower CV (42%) was found for variation between floors, whereas room-to-room CV on the same floor ranged from 25% at first floor level to 48% at basement level. Floor mean ratios, with ground floor as the reference level, were calculated for each building in order to study the correlation between radon concentration and floor levels. Although no clear trend was observed, the average basement/ground floor ratio of radon concentrations resulted about 2.0, whereas the average sixth floor/ground floor ratio of radon concentrations was 0.5. Some discussion on the potential impact of the results of this study on policies and radon regulations are also included in

  9. A statistical evaluation of the geogenic controls on indoor radon concentrations and radon risk

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D., E-mail: jda@bgs.ac.u [British Geological Survey, Kingsley Dunham Centre, Nicker Hill, Keyworth, Nottingham, NG12 5GG (United Kingdom); Miles, J.C.H. [Health Protection Agency (HPA), Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2010-10-15

    ANOVA is used to show that approximately 25% of the total variation of indoor radon concentrations in England and Wales can be explained by the mapped bedrock and superficial geology. The proportion of the total variation explained by geology is higher (up to 37%) in areas where there is strong contrast between the radon potential of sedimentary geological units and lower (14%) where the influence of confounding geological controls, such as uranium mineralisation, cut across mapped geological boundaries. When indoor radon measurements are grouped by geology and 1-km squares of the national grid, the cumulative percentage of the variation between and within mapped geological units is shown to be 34-40%. The proportion of the variation that can be attributed to mapped geological units increases with the level of detail of the digital geological data. This study confirms the importance of radon maps that show the variation of indoor radon concentrations both between and within mapped geological boundaries.

  10. Development of a model for radon concentration in indoor air

    International Nuclear Information System (INIS)

    Jelle, Bjørn Petter

    2012-01-01

    A model is developed for calculation of the radon concentration in indoor air. The model takes into account various important parameters, e.g. radon concentration in ground, radon diffusion resistance of radon barrier, air permeance of ground, air pressure difference between outdoor ground and indoor at ground level, ventilation of the building ground and number of air changes per hour due to ventilation. Characteristic case studies are depicted in selected 2D and 3D graphical plots for easy visualization and interpretation. The radon transport into buildings might be dominated by diffusion, pressure driven flow or a mixture of both depending on the actual values of the various parameters. The results of our work indicate that with realistic or typical values of the parameters, most of the transport of radon from the building ground to the indoor air is due to air leakage driven by pressure differences through the construction. By incorporation of various and realistic values in the radon model, valuable information about the miscellaneous parameters influencing the indoor radon level is gained. Hence, the presented radon model may be utilized as a simple yet versatile and powerful tool for examining which preventive or remedial measures should be carried out to achieve an indoor radon level below the reference level as set by the authorities. - Highlights: ► Model development for calculation of radon concentration in indoor air. ► Radon model accounting for various important parameters. ► Characteristic case studies depicted in 2D and 3D graphical plots. ► May be utilized for examining radon preventive measures.

  11. Prediction of indoor radon concentration based on residence location and construction

    International Nuclear Information System (INIS)

    Maekelaeinen, I.; Voutilainen, A.; Castren, O.

    1992-01-01

    We have constructed a model for assessing indoor radon concentrations in houses where measurements cannot be performed. It has been used in an epidemiological study and to determine the radon potential of new building sites. The model is based on data from about 10,000 buildings. Integrated radon measurements were made during the cold season in all the houses; their geographic coordinates were also known. The 2-mo measurement results were corrected to annual average concentrations. Construction data were collected from questionnaires completed by residents; geological data were determined from geological maps. Data were classified according to geographical, geological, and construction factors. In order to describe different radon production levels, the country was divided into four zones. We assumed that the factors were multiplicative, and a linear concentration-prediction model was used. The most significant factor in determining radon concentration was the geographical region, followed by soil type, year of construction, and type of foundation. The predicted indoor radon concentrations given by the model varied from 50 to 440 Bq m -3 . The lower figure represents a house with a basement, built in the 1950s on clay soil, in the region with the lowest radon concentration levels. The higher value represents a house with a concrete slab in contact with the ground, built in the 1980s, on gravel, in the region with the highest average radon concentration

  12. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  13. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989–2013

    Science.gov (United States)

    Casey, Joan A.; Ogburn, Elizabeth L.; Rasmussen, Sara G.; Irving, Jennifer K.; Pollak, Jonathan; Locke, Paul A.

    2015-01-01

    Background Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). Objectives We evaluated predictors of indoor radon concentrations. Methods Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Results Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167–679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52–178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = –0.323, 95% CI: –0.333, –0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989–2013. Environ Health Perspect 123:1130–1137; http://dx.doi.org/10.1289/ehp.1409014 PMID:25856050

  14. Determination of the Radon Concentration and Radioactivity Level in Karaca Cave

    International Nuclear Information System (INIS)

    Kara, A.

    2008-01-01

    In this study, the radon gas concentration in the Karaca cave which is open to tourism has been determined and the negative effects of radon gas on people were discussed. Karaca cave (Gumushane) is visited by many tourists every year. The measurements of radon gas concentration which affects the health of human beings negatively and even causes the lung cancer when it reaches high points have been done for the summer and winter season. LR-115 passive radon detector was used to determine radon concentrations in the cave both winter and summer season. The average radon concentration in the Karaca cave were determined as 823 Bq/m 3 and 1023 Bq/m 3 for the summer and winter season, respectively. Moreover, to find out the natural radioactivity in the cave, the gamma spectroscopic analysis of soil, stone and stalagmite samples were carried out and their relations with the radon gas in the cave atmosphere was analyzed

  15. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    The radon content of drinking water samples was determined with Alpha Guard Pro equipped with an appropriate unit (Aqua Kit). The samples were collected from water taps in dwellings located at various cities in Greece and Cyprus. In addition, surface water samples from rivers, lakes and seas as well as potable underground and hot spring water samples from Greece and Cyprus were also collected. For a precise determination of radon concentration in water samples, special procedures were followed both for sampling and transportation, as well as for measurement. Intercomparison experiments were designed and implemented before and during the study. Radon concentrations in drinking water samples in Greece ranged between 1.1 ± 0.5 Bq/L and 410±50 Bq/L. The corresponding concentrations in Cyprus ranged between 1.3 ± 0.8 Bq/L and 15±4 Bq/L. Three samples collected from the city of Arnea Chalkidikis (Northern Greece) exhibited high concentrations of 120±20 Bq/L, 320±40 Bq/L and 410±50 Bq/L. This city is identified as a high radon potential area. One water sample located in Lesvos Island (North-East part of Greece) exhibited radon concentration 140±20 Bq/L. Additional six samples displayed high concentrations in potable hot spring water samples. These samples which were collected from the city of Loutraki (Peloponnesus) ranged between 220-230 Bq/L. In addition, two samples characterized as 'medicinal drinking water' gave concentrations between 320 Bq/L and 340 Bq/L. For underground water samples the radon concentrations ranged between 1.2±0.7 Bq/L and 15±4 Bq/L, while for surface water samples the range was 2.7±0.8 Bq/L to 24±6 Bq/L. The observed concentrations of radon gas in potable water samples in Greece were found to be largely low. In Cyprus, they were all well below 15 Bq/L

  16. Effect of ventilation rate on concentrations of indoor radon and its progenies

    International Nuclear Information System (INIS)

    Wang Chunhong; Liu Yanyang; Liu Fudong; Liu Senlin; Chen Ling

    2012-01-01

    To study concentrations of indoor radon and its progenies, ventilation rates and their corresponding concentrations of indoor radon and its progenies were measured using tracer-gas dilution method. Results show that both ventilation rates and concentrations of indoor radon varied insignificantly and radon concentration were higher than the outdoor environment while doors and windows were all closed with air-conditioner on and off respectively; the concentrations declined and close to the outdoor level when doors and windows were all open with ventilators in operation. Accordingly, in modern life, especially in summer, people's preference for air-conditioners but natural ventilation would result in an increase of indoor radon concentration. (authors)

  17. The measurement of radon concentration of soil in a civil construction site

    International Nuclear Information System (INIS)

    Liu Hanbin; Fan Guang

    2004-01-01

    Radon is one of radioactive resources which do harm to human body. Therefore, its concentration in the soil should be measured before the civil construction works. Code for Indoor Environmental Pollution Control of Civil Building Engineering (GB50325-2001) is the main norm used for soil radon concentration measurement. By using FD-3017 RaA radon measuring equipment, the soil radon concentration in a civil building engineering site has been measured, the result shows that the concentration is lower than the regional average value, radon protective measures should not be installed in that site. (authors)

  18. Indoor radon concentrations and radon doses at three districts of Ankara, Turkey and raising public awareness on the issue

    International Nuclear Information System (INIS)

    Mehmet Kildir; Inci Goekmen; Ali Goekmen

    2016-01-01

    Indoor radon concentrations at METU, CIGDEM and DOSTLAR in Ankara were measured using electrets. The statistical analysis of the data indicated a lognormal distribution of radon concentrations, with no significant difference between CIGDEM and DOSTLAR with geometric means of GM = 87.5 and 54.5 Bq m -3 , respectively. Radon concentrations did not change seasonally at CIGDEM which contain modern buildings, but at the slum district DOSTLAR, with poor insulation of houses a seasonal variation was observed. Annual effective radon doses were estimated (0.4-8.4 mSv). Public awareness about indoor radon was raised. (author)

  19. Indoor radon concentration levels in Amman, Zarka and Sault

    International Nuclear Information System (INIS)

    Khatibeh, A.J.A.H.; Ahmad, N.; Matiullah, A.

    1997-01-01

    Indoor radon concentration levels in three main cities of Jordan have been measured using CR-39 polymeric nuclear track detectors. CR-39 detectors were placed in polyethylene bags and cups. These bag and cup dosimeters were installed in randomly selected houses. The average value of indoor radon concentration level in the city of Amman was found to be 41.3 Bq m -3 with cup dosimeters and 42.6 Bq m -3 with bag dosimeters. For the district of Zarka, the average value of indoor radon concentration level measured with bag dosimeters was 33.9 Bq m -3 , whereas with cup dosimeters the level was 30.7 Bq m -3 . For Sault and its suburbs, the average value of indoor radon concentration level was found to be 51.2 Bq m -3 with bag dosimeters and 49.8 Bq m -3 with cup dosimeters. (author)

  20. Laboratory measurements of the influence of air treatment devices on radon daughters

    International Nuclear Information System (INIS)

    Rajala, M.; Janka, K.; Graeffe, G.; Kulmala, V.; Lehtimaeki, M.

    1984-01-01

    This paper presents laboratory measurements in which the effect of air cleaners on radon decay products has been studied. Experiments show that both a high-efficiency particulate air filter and an electrostatic precipitator substantially decrease the total airborne radon daughter concentration leading to a situation where most of the decay products are unattached. However, in some situations the concentration of fine particles generated by the corona discharge in the electronic air cleaner becomes high enough to increase the total radon daughter concentration and decrease the free decay product concentration. Impurities in the air may have a notable role in the formation of these condensation nuclei. (Author)

  1. Radon concentration and natural radioactivity evaluation in the Vysehrad casemates

    International Nuclear Information System (INIS)

    Berka, Z.; Thinova, L.; Stepan, M.

    2004-01-01

    The Vysehrad casemates formed a part of Prague's defense system in the middle ages. The casemates consist of a large system of underground corridors (which are in direct contact with subsoils) that run around the whole Vysehrad hill. The corridors are covered by an artificially made-up ground. Although there are many vents and embrasures in the casemates, investigation of radon accumulation in the casemates is of interest. A comprehensive radon and natural radioactivity survey has been carried out on the Vysehrad hill as part of special scientific programme for secondary school students. No extreme radon concentration or extremely high natural radioactivity has been observed. The highest radon concentration were measured in the blind parts of corridors that are normally unused. The radon concentrations found can be described as health-safe

  2. Radon concentrations in some Egyptian dwellings using LR 115 detectors

    International Nuclear Information System (INIS)

    Hussein, A.S.

    2007-01-01

    Radon, a well-established risk factor for human lung cancer, is present at low concentrations in most homes. Consequently, many countries have established national guidelines for residential radon concentrations. This survey provides additional information about indoor radon concentrations in Egypt. Indoor radon survey of a total of 15 randomly selected houses in Qena city, Upper Egypt was carried out. LR 115 detectors were exposed for one year, covering all the seasons. The estimated indoor radon levels varied from 19 to 59 Bq m 3 with an average of 40 Bq m 3 . Using the bare and filtered LR 115 detectors, the average equilibrium factor F was assessed as 0.30 indoors. An average annual effective dose of 0.40 mSv has been estimated and was found to be lower than the ICRP-65

  3. Radon exhalation rates from slate stone samples in Aravali Range in Haryana

    International Nuclear Information System (INIS)

    Upadhyay, S.B.; Kant, K.; Chakarvarti, S.K.

    2012-01-01

    The slate stone tiles are very popular in covering the walls of the rooms. Radon is released into ambient air from slate stones due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in slates stones is related to radioactivity in the rocks from which the slate stone tiles are formed. In the present investigation, the radon emanated from slate stone samples collected from different slate mines in Aravali range of hills in the Haryana state of Northern India has been estimated. For the measurement of radon concentration emanated from these samples, alpha-sensitive LR-115 type II plastic track detectors have been used. The alpha particles emitted from the radon form tracks in these detectors. After chemical etching the track density of registered tracks is used to calculate radon concentration and exhalation rates of radon using required formulae. The measurements indicate normal to some higher levels of radon concentration emanated from the slat stone samples collected from Aravali range of hills in north India. The results will be discussed in full paper. (author)

  4. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  5. Survey on radon concentration of civil air defense shelter in Hengyang

    International Nuclear Information System (INIS)

    Tang Quan; Ma Xiao

    2011-01-01

    In this paper, the radon concentration of civil air defense shelter was surveyed in Hengyang area, where there is higher background of radon concentration. If civil air defense shelter is not pressure-tight, the average radon concentration is about 55.9 -167.3 Bq/m 3 , lower than the intervened quantity: 200 Bq/m 3 , which is given by the international commission on radiological protection (ICRP). Maybe radon protection is not needed with the ventilation of civil air defense shelter like that. The radon concentration of airtight civil air defense shelter change along with the season, which is lower in spring and higher in autumn. The results can be a reference for using civil air defense shelter during the time of peace or war. (authors)

  6. Comparison of calculated and measured soil-gas radon concentration and radon exhalation rate

    International Nuclear Information System (INIS)

    Neznal, Martin; Neznal, Matej; Jiranek, Martin

    2000-01-01

    The computer model RADON2D for WINDOWS, which makes it possible to estimate the radon exhalation rate from the ground surface and the distribution of soil-gas radon concentration, was tested using a large set of experimental data coming from four reference areas located in regions with different geological structure. A good agreement between calculated and experimental data was observed. In the majority of cases, a correct description of the real situation was obtained using non-modified experimental input data. (author)

  7. Soil radium, soil gas radon and indoor radon empirical relationships to assist in post-closure impact assessment related to near-surface radioactive waste disposal.

    Science.gov (United States)

    Appleton, J D; Cave, M R; Miles, J C H; Sumerling, T J

    2011-03-01

    Least squares (LS), Theil's (TS) and weighted total least squares (WTLS) regression analysis methods are used to develop empirical relationships between radium in the ground, radon in soil and radon in dwellings to assist in the post-closure assessment of indoor radon related to near-surface radioactive waste disposal at the Low Level Waste Repository in England. The data sets used are (i) estimated ²²⁶Ra in the < 2 mm fraction of topsoils (eRa226) derived from equivalent uranium (eU) from airborne gamma spectrometry data, (ii) eRa226 derived from measurements of uranium in soil geochemical samples, (iii) soil gas radon and (iv) indoor radon data. For models comparing indoor radon and (i) eRa226 derived from airborne eU data and (ii) soil gas radon data, some of the geological groupings have significant slopes. For these groupings there is reasonable agreement in slope and intercept between the three regression analysis methods (LS, TS and WTLS). Relationships between radon in dwellings and radium in the ground or radon in soil differ depending on the characteristics of the underlying geological units, with more permeable units having steeper slopes and higher indoor radon concentrations for a given radium or soil gas radon concentration in the ground. The regression models comparing indoor radon with soil gas radon have intercepts close to 5 Bq m⁻³ whilst the intercepts for those comparing indoor radon with eRa226 from airborne eU vary from about 20 Bq m⁻³ for a moderately permeable geological unit to about 40 Bq m⁻³ for highly permeable limestone, implying unrealistically high contributions to indoor radon from sources other than the ground. An intercept value of 5 Bq m⁻³ is assumed as an appropriate mean value for the UK for sources of indoor radon other than radon from the ground, based on examination of UK data. Comparison with published data used to derive an average indoor radon: soil ²²⁶Ra ratio shows that whereas the published data are

  8. Radon exhalation of hardening concrete: monitoring cement hydration and prediction of radon concentration in construction site.

    Science.gov (United States)

    Kovler, Konstantin

    2006-01-01

    The unique properties of radon as a noble gas are used for monitoring cement hydration and microstructural transformations in cementitious system. It is found that the radon concentration curve for hydrating cement paste enclosed in the chamber increases from zero (more accurately - background) concentrations, similar to unhydrated cement. However, radon concentrations developed within 3 days in the test chamber containing cement paste were approximately 20 times higher than those of unhydrated cement. This fact proves the importance of microstructural transformations taking place in the process of cement hydration, in comparison with cement grain, which is a time-stable material. It is concluded that monitoring cement hydration by means of radon exhalation method makes it possible to distinguish between three main stages, which are readily seen in the time dependence of radon concentration: stage I (dormant period), stage II (setting and intensive microstructural transformations) and stage III (densification of the structure and drying). The information presented improves our understanding of the main physical mechanisms resulting in the characteristic behavior of radon exhalation in the course of cement hydration. The maximum value of radon exhalation rate observed, when cement sets, can reach 0.6 mBq kg(-1) s(-1) and sometimes exceeds 1.0 mBq kg(-1) s(-1). These values exceed significantly to those known before for cementitious materials. At the same time, the minimum ventilation rate accepted in the design practice (0.5 h(-1)), guarantees that the concentrations in most of the cases will not exceed the action level and that they are not of any radiological concern for construction workers employed in concreting in closed spaces.

  9. Measurement of radon concentration in water with Lucas cell detector

    International Nuclear Information System (INIS)

    Machaj, B.; Pienkos, J.P.

    2003-01-01

    A method for the measurement of radon concentration in water is presented based on flushing a water sample with air in a closed loop with the Lucas cell as alpha radiation detector. The main feature of the method is washing radon away from the larger sample of water (0.75 l) to a small volume of air, approximately 0.5 l, thanks to which a high radon concentration in air and a considerable sensitivity of measurement is achieved. Basic relations and results of measurements of a model of a gauge is given. The estimated measuring sensitivity (S) is 8.5 (cpm)/(Bq/l). The random error due to the statistical fluctuations of count rate at radon concentrations 1,10, 100, 1000, 10000 Bq/l is 11, 3.6, 1.1, 0.4, 0.1% correspondingly at a counting (measuring) time of 10 min. The minimum detectable radon concentration in water is 0.11 Bq/l. (author)

  10. Investigation of the areas of high radon concentration in Gyeongju

    International Nuclear Information System (INIS)

    Lee, Jung Min; Park, Chan Hee; Kim, Shin Jae; Moon, Joo Hyun

    2013-01-01

    The aim of this study was to survey the radon concentrations at 21 elementary schools in Gyeongju, Republic of Korea, to identify those schools with high radon concentrations. Considering their geological characteristics and the preliminary survey results, three schools were finally placed under close scrutiny. For these three schools, continuous measurements over 48 h were taken at the principal's and administration office. The radon concentrations at one school, Naenam, exceeded the action level (148 Bq/m 3 ) established by the U.S. EPA, while those at the other two schools were below that level. - Highlights: • Preliminary measurements of the indoor radon concentrations were performed at the auditoriums in 23 elementary schools in Gyeongju. • Considering the geological characteristics and preliminary survey results, three elementary schools were screened for closer scrutiny. • For the three schools, continuous measurements were made at their principal's and administration offices over 48-h period. • The scrutiny revealed one elementary school of high radon concentration much higher than the U.S. EPA action level

  11. Radon concentrations in some Egyptian dwellings using LR 115 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, A S [Radiation Protection Department, Nuclear Power Plants Authority, Cairo (Egypt)

    2007-06-15

    Radon, a well-established risk factor for human lung cancer, is present at low concentrations in most homes. Consequently, many countries have established national guidelines for residential radon concentrations. This survey provides additional information about indoor radon concentrations in Egypt. Indoor radon survey of a total of 15 randomly selected houses in Qena city, Upper Egypt was carried out. LR 115 detectors were exposed for one year, covering all the seasons. The estimated indoor radon levels varied from 19 to 59 Bq m{sup 3} with an average of 40 Bq m{sup 3}. Using the bare and filtered LR 115 detectors, the average equilibrium factor F was assessed as 0.30 indoors. An average annual effective dose of 0.40 mSv has been estimated and was found to be lower than the ICRP-65.

  12. Daily fluctuations in radon concentration in a Cordoba factory complex

    International Nuclear Information System (INIS)

    Germanier, A.; Perez, R.; Rubio, M.

    1998-01-01

    Full text: This work shows the fluctuations of indoor radon concentration in some rooms placed inside a Cordoba Factory Complex. The measurements were performed by Victoreen Radon Monitor. The system was shaped to sample single radon concentration values after one hour integration. It utilizes a passive diffusion chamber and a silicon diffused junction detector. A portion of decay products will plate-out onto the detector and emit alpha particles into the depletion region of a diffused junction detector. The alpha energy is deposited in the detector in the form of ionization which generates a charge pulse. Only alpha pulses of an energy level similar Po-218 and Po-214 are detected. The study of the meteorological parameters shows that the daily fluctuations of the radon concentration respond to the transport and dispersion processes of radon gas through the air. Air temperature, wind's direction and speed are found to be fundamentals parameters in the observed time behavior. The meteorological data were obtained by a portable station (Davis Weathe Monitor II). The radon concentration present a maximum value (1850 Bq/m 3 ) at the night and a minimum value (150 Bq/m 3 ) at the day. (author) [es

  13. A study of radon indoor concentration

    International Nuclear Information System (INIS)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G.

    2000-01-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m 3 obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  14. A reconnaissance study of radon concentrations in Hamadan city, Iran

    Directory of Open Access Journals (Sweden)

    G. K. Gillmore

    2010-04-01

    Full Text Available This paper presents results of a reconnaissance study that used CR-39 alpha track-etch detectors to measure radon concentrations in dwellings in Hamadan, western Iran, significantly, built on permeable alluvial fan deposits. The indoor radon levels recorded varied from 4 (i.e. below the lower limit of detection for the method to 364 Bq/m3 with a mean value of 108 Bq/m3 which is 2.5 times the average global population-weighted indoor radon concentration – these data augment the very few published studies on indoor radon levels in Iran. The maximum radon concentration in Hamadan occurs during the winter period (January to March with lower concentrations during the autumn. The effective dose equivalent to the population in Hamadan is estimated from this study to be in the region of 2.7 mSv/y, which is above the guidelines for dose to a member of the public of 1 mSv/y suggested by the International Commission on Radiological Protection (ICRP in 1993. This study supports other work in a number of countries that indicates such permeable "surficial" deposits as being of intermediate to high radon potential. In western Iran, the presence of hammered clay floors, the widespread presence of excavated qanats, the textural properties of surficial deposits and human behaviour intended to cope with winds are likely to be important factors influencing radon concentrations in older buildings.

  15. Comparison of predicted and measured variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Maekelaeinen, I.; Castren, O.; Winqvist, K.

    1988-01-01

    Prediction of the variations of indoor radon concentration were calculated using a model relating indoor radon concentration to radon entry rate, air infiltration and meteorological factors. These calculated variations have been compared with seasonal variations of 33 houses during 1-4 years, with winter-summer concentration ratios of 300 houses and the measured diurnal variation. In houses with a slab in ground contact the measured seasonal variations are quite often in agreement with variations predicted for nearly pure pressure difference driven flow. The contribution of a diffusion source is significant in houses with large porous concrete walls against the ground. Air flow due to seasonally variable thermal convection within eskers strongly affects the seasonal variations within houses located thereon. Measured and predicted winter-summer concentration ratios demonstrate that, on average, the ratio is a function of radon concentration. The ratio increases with increasing winter concentration. According to the model the diurnal maximum caused by a pressure difference driven flow occurs in the morning, a finding which is in agreement with the measurements. The model presented can be used for differentiating between factors affecting radon entry into houses. (author)

  16. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  17. Lung cancer mortality and indoor radon concentrations in 18 Canadian cities

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Mao, Y.; McGregor, R.G.; Semenciw, R.; Smith, M.H.; Wigle, D.T.

    1983-01-01

    Indoor radon and radon daughter concentrations were measured in a survey of 14,000 homes in 18 Canadian cities conducted in the summers of 1978 through 1980. Mortality and population data for the period 1966 through 1979 were retrieved for the geographic areas surveyed in each city. The results of analysis of the relation between lung cancer and radon daughter concentration, smoking habits and socioeconomic indicators for each city showed no detectable association between radon daughter concentrations and lung cancer mortality rates with or without adjustment for differences in smoking habits between cities

  18. The Correlation between Radon Emission Concentration and Subsurface Geological Condition

    Science.gov (United States)

    Kuntoro, Yudi; Setiawan, Herru L.; Wijayanti, Teni; Haerudin, Nandi

    2018-03-01

    Exploration activities with standard methods have already encountered many obstacles in the field. Geological survey is often difficult to find outcrop because they are covered by vegetation, alluvial layer or as a result of urban development and housing. Seismic method requires a large expense and licensing in the use of dynamite is complicated. Method of gravity requires the operator to go back (looping) to the starting point. Given some of these constraints, therefore it needs a solution in the form of new method that can work more efficiently with less cost. Several studies in various countries have shown a correlation between the presence of hydrocarbons and Radon gas concentration in the earth surface. By utilizing the properties of Radon that can migrate to the surface, the value of Radon concentration in the surface is suggested to provide information about the subsurface structure condition. Radon is the only radioactive substance that gas-phased at atmospheric temperature. It is very abundant in the earth mantle. The vast differences of temperatures and pressures between the mantle and the earth crust cause the convection flow toward earth surface. Radon in gas phase will be carried by convection flow to the surface. The quantity of convection currents depend on the porosity and permeability of rocks where Radon travels within, so that Radon concentration in the earth surface delineates the porosity and permeability of subsurface rock layers. Some measurements were carried out at several locations with various subsurface geological conditions, including proven oil fields, proven geothermal field, and frontier area as a comparison. These measurements show that the average and the background concentration threshold in the proven oil field (11,200 Bq/m3) and proven geothermal field (7,820 Bq/m3) is much higher than the quantity in frontier area (329 and 1,620 Bq/m3). Radon concentration in the earth surface is correlated with the presence of geological

  19. Measurement of the concentration of radon in the air

    International Nuclear Information System (INIS)

    Aten, J.B.Th.; Bierhuizen, H.W.J.; Hoek, L.P. van; Ros, D.; Weber, J.

    1975-01-01

    A simple transportable air monitoring apparatus was developed for controlling the radon contamination of air in laboratory rooms. It is not highly accurate but is sufficient to register the order of magnitude of the radon concentration. Air is pumped through a filter for one or two hours and an alpha decay curve of the dust on the filter is determined. Scintillation counting forty minutes after sampling indicates the radon activity. The calibration method of measuring the equilibrium of daughter product concentrations is discussed extensively

  20. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    A total of 35 measurements in Greece and 15 in Cyprus were performed. Radon concentrations in drinking water in Greece were from (1.1±0.5) to (410±50) Bq/L. The corresponding concentrations in underground potable waters in Cyprus ranged between (0.4±0.3) Bq/L and (15±4) Bq/L. High concentrations, viz. (120±20), (320±40) and (410±50) Bq/L, were observed in three samples collected from the city of Arnea Chalkidekis in northern Greece. One water sample from Lesvos Island (north-eastern part of Greece) exhibited a radon concentration of (140±20) Bq/L. Six samples of hot spring water from the city of Loutraki (Attica prefecture), characterized as 'medicinal drinking water', contained concentrations of radon between (220±10) and (340±20) Bq/L. Radon concentrations in potable and non-potable underground water in Greece and Cyprus ranged between (0.4±0.3) and (15±4) Bq/L, whereas in surface water the range was from (2.7±0.8) to (24±6) Bq/L. (P.A.)

  1. Atmospheric radon daughters concentration inside and outside of cloud

    International Nuclear Information System (INIS)

    Nishikawa, Tsuguo; Okabe, Shigeru; Aoki, Masayoshi; Imamura, Takakazu; Iwata, Yoshitomo; Tamura, Yukihide; Tsuboguchi, Masayasu

    1987-01-01

    The measurements of the atmospheric radon daughters concentration in and out of the cloud were carried out on the top of the mountain, and in the upper air of the sea by using the airplane. The difference of the concentrations between inside and outside of the stratus measured on the top of the mountain was not clear. The atmospheric radon daughters concentration at the top of the mountain decreased when the amount of precipitation at that point was large. Concerning the cumulus investigated by using the airplane, the concentration in the cloud was a little higher than the concentration out of the cloud. Results of the measurements show that the cloud seems to be constructed of the various air masses whose radon daughters concentrations are different from each other even though it appears to be uniform. (author)

  2. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  3. Role of environmental variables on radon concentration in soil

    International Nuclear Information System (INIS)

    Climent, H.; Bakalowicz, M.; Monnin, M.

    1998-01-01

    In the frame of an European project, radon concentrations in soil and measurements of environmental variables such as the nature of the soil or climatic variables were monitored. The data have been analysed by time-series analysis methods, i.e. Correlation and Spectrum Analysis, to point out relations between radon concentrations and some environmental variables. This approach is a compromise between direct observation and modelling. The observation of the rough time series is unable to point out the relation between radon concentrations and an environmental variable because of the overlapping of the influences of several variables, and the time delay induced by the medium. The Cross Spectrum function between the time series of radon and of an environmental variable describes the nature of the relation and gives the response time in the case of a cause to effect relation. It requires the only hypothesis that the environmental variable is the input function and radon concentration the output function. This analysis is an important preliminary study for modelling. By that way the importance of soil nature has been pointed out. The internal variables of the medium (permeability, porosity) appear to restrain the influence of the environmental variables such as humidity, temperature or atmospheric pressure. (author)

  4. Influence of indoor air conditions on radon concentration in a detached house

    International Nuclear Information System (INIS)

    Akbari, Keramatollah; Mahmoudi, Jafar; Ghanbari, Mahdi

    2013-01-01

    Radon is released from soil and building materials and can accumulate in residential buildings. Breathing radon and radon progeny for extended periods hazardous to health and can lead to lung cancer. Indoor air conditions and ventilation systems strongly influence indoor radon concentrations. This paper focuses on effects of air change rate, indoor temperature and relative humidity on indoor radon concentrations in a one family detached house in Stockholm, Sweden. In this study a heat recovery ventilation system unit was used to control the ventilation rate and a continuous radon monitor (CRM) was used to measure radon levels. FLUENT, a computational fluid dynamics (CFD) software package was used to simulate radon entry into the building and air change rate, indoor temperature and relative humidity effects using a numerical approach. The results from analytical solution, measurements and numerical simulations showed that air change rate, indoor temperature and moisture had significant effects on indoor radon concentration. Increasing air change rate reduces radon level and for a specific air change rate (in this work Ach = 0.5) there was a range of temperature and relative humidity that minimized radon levels. In this case study minimum radon levels were obtained at temperatures between 20 and 22 °C and a relative humidity of 50–60%. - Highlights: ► We use CFD to simulate indoor radon concentration and distribution. ► The effects of ventilation rate, temperature and moisture are investigated. ► Model validation is performed through analytical solution and measurement results. ► Results show that ventilation rate is inversely proportional to radon level. ► There is a range of temperature and relative humidity that minimize radon level.

  5. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  6. Measurement of Radon concentration in groundwater by technique of nuclear track detector

    International Nuclear Information System (INIS)

    Trinh Van Giap; Nguyen Manh Hung; Dang Duc Nhan

    2000-01-01

    A method for measuring radon concentration in groundwater using nuclear track detector LR-115 stripping is reported. The radon-monitoring device in groundwater is a small box with two pieces of nuclear track detector and all these materials is placed in a plastic bag made by polyethylene. It is very suitable to measure radon concentration in groundwater well in long term. Alpha tracks produced by radon and it daughter on nuclear track detector is counted automatically by spark counting method. The paper also presents some results of radon concentration in some groundwater well and mineral water sources. (author)

  7. Indoor radon concentrations in kindergartens from different regions of Yugoslavia

    International Nuclear Information System (INIS)

    Vaupotic, J.; Krizman, M.; Sutej, T.

    1992-01-01

    In the winter period of 1990-1991 instantaneous radon concentrations in air were measured in around 450 kindergartens from different regions from Yugoslavia. Alpha scintillation counting was used as a screening method, and the measurements were carried out in rooms where the children spent the majority of their time. All of the air grab samples were taken under the same conditions which excluded ventilation of the interior 12 h prior to sampling. In addition to indoor radon concentrations, gamma dose rate was measured using portable equipment. The indoor radon concentrations were generally low, in the range from 10 to 180 Bq.m -3 of air, with an overall average of about 100 Bq.m -3 . There were a few exceptions where indoor radon levels exceeded 150 Bq.m -3 ; mainly in old buildings containing higher contents of natural radionuclides in the building materials, and in the cellars or basements of the buildings. In all rooms with a level exceeding 150 Bq of 222 Rn per m 3 , solid-state nuclear track detectors were applied for long-term measurements. In order to investigate the equilibrium between radon and its short-lived daughters, mainly with respect to their contribution to the effective dose, alpha spectrometry is also being introduced in selected kindergartens with elevated radon concentrations. (author)

  8. Seasonal variations of indoor radon concentrations

    International Nuclear Information System (INIS)

    Majborn, B.

    1990-01-01

    Seasonal variations of indoor radon concentrations have been studied in a cluster of 10 single-family houses. Eight of the houses are of a similar construction with slab-on-grade foundations. The remaining two houses have different substructures, one of them having a crawl space, and the other having partly a basement and partly a crawl space. A 'normal' seasonal variation of the radon concentration with a maximum in winter and a minimum in summer was observed in most of the houses. In these houses the variation showed a strong correlation with the indoor-outdoor temperature difference on a 2-month basis. However, deviating seasonal variations were observed in some of the houses, notably in the two houses having different substructures. This paper reports that a re-examination of the data obtained in a previous study indicates that winter/summer ratios of indoor radon concentrations in Danish houses depend on the house substructure. The mean winter/summer ratios were about 2.1 for houses with slab-on-grade foundations, 1.5 for houses having a basement, and 1.0 for houses with a crawl space (geometric mean values). However, a study with more houses in each substructure category will be needed to show whether or not the indicated differences are generally valid for Danish houses

  9. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    Risk assessment due to radon exposure indoors is based on annual average indoor radon activity concentration. To assess the radon exposure in a building, measurement is generally performed during at least two months during heating period in order to be representative of the annual average value. This is because radon presence indoors could be very variable during time. This measurement protocol is fairly reliable but may be a limiting in the radon risk management, particularly during a real estate transaction due to the duration of the measurement and the limitation of the measurement period. A previous field study defined a rapid methodology to characterize radon entry in dwellings. The objective of this study was at first, to test this methodology in various dwellings to assess its relevance with a daily test. At second, a ventilation model was used to assess numerically the air renewal of a building, the indoor air quality all along the year and the annual average indoor radon activity concentration, based on local meteorological conditions, some building characteristics and in-situ characterization of indoor pollutant emission laws. Experimental results obtained on thirteen individual dwellings showed that it is generally possible to obtain a representative characterization of radon entry into homes. It was also possible to refine the methodology defined in the previous study. In addition, numerical assessments of annual average indoor radon activity concentration showed generally a good agreement with measured values. These results are encouraging to allow a procedure with a short measurement time to be used to characterize long-term radon potential in dwellings. - Highlights: • Test of a daily procedure to characterize radon potential in dwellings. • Numerical assessment of the annual radon concentration. • Procedure applied on thirteen dwellings, characterization generally satisfactory. • Procedure useful to manage radon risk in dwellings, for real

  10. Study of temporal variation of radon concentrations in public drinking water supplies

    International Nuclear Information System (INIS)

    York, E.L.

    1995-01-01

    The Environmental Protection Agency (EPA) has proposed a Maximum Contaminant Level (MCL) for radon-222 in public drinking water supplies of 300 pCi/L. Proposed monitoring requirements include collecting quarterly grab samples for the first year, then annual samples for the remainder of the compliance cycle provided first year quarterly samples average below the MCL. The focus of this research was to study the temporal variation of groundwater radon concentrations to investigate how reliably one can predict an annual average radon concentration based on the results of grab samples. Using a open-quotes slow-flowclose quotes collection method and liquid scintillation analysis, biweekly water samples were taken from ten public water supply wells in North Carolina (6 month - 11 month sampling periods). Based on study results, temporal variations exist in groundwater radon concentrations. Statistical analysis performed on the data indicates that grab samples taken from each of the ten wells during the study period would exhibit groundwater radon concentrations within 30% of their average radon concentration

  11. Factors influencing indoor concentrations of radon and daughter products

    International Nuclear Information System (INIS)

    Wang Hengde

    1985-01-01

    The correlation between indoor concentrations of 222 Rn and its daughters and some influencing factors is discussed and expressions of concentrations are derived with relation to radon exhalation rate from indoor surfaces, air exchange rate and daughter deposition velocities on indoor surfaces. Experimental methods for determining radon exhalation rate, air exchange rate and daughter deposition velocities are also mentioned

  12. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  13. Radon concentration distributions in shallow and deep groundwater around the Tachikawa fault zone.

    Science.gov (United States)

    Tsunomori, Fumiaki; Shimodate, Tomoya; Ide, Tomoki; Tanaka, Hidemi

    2017-06-01

    Groundwater radon concentrations around the Tachikawa fault zone were surveyed. The radon concentrations in shallow groundwater samples around the Tachikawa fault segment are comparable to previous studies. The characteristics of the radon concentrations on both sides of the segment are considered to have changed in response to the decrease in groundwater recharge caused by urbanization on the eastern side of the segment. The radon concentrations in deep groundwater samples collected around the Naguri and the Tachikawa fault segments are the same as those of shallow groundwater samples. However, the radon concentrations in deep groundwater samples collected from the bedrock beside the Naguri and Tachikawa fault segments are markedly higher than the radon concentrations expected from the geology on the Kanto plane. This disparity can be explained by the development of fracture zones spreading on both sides of the two segments. The radon concentration distribution for deep groundwater samples from the Naguri and the Tachikawa fault segments suggests that a fault exists even at the southern part of the Tachikawa fault line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Radon and thoron concentrations in offices and dwellings of the Gunma prefecture, Japan

    International Nuclear Information System (INIS)

    Sugino, M.; Tokonami, S.; Zhuo, W.

    2005-01-01

    A one year survey of indoor radon and thoron concentrations was carried out in offices and dwellings of the Gunma prefecture, Japan. A passive integrating radon and thoron discriminative monitor was used in the survey. The annual mean radon concentration was 22±14 Bq x m -3 , and ranged from 12 to 93 Bq x m -3 among the 56 surveyed rooms. Radon concentration in offices was generally higher than that in the dwellings, with the arithmetic averages of 29 and 17 Bq x m -3 , respectively. Radon concentrations were generally lower in the traditional Japanese wooden houses than those houses built with other building materials. Seasonal variation of indoor radon was also observed in this survey. Compared to summer and autumn, radon concentrations were generally higher in spring and winter. The mean value of thoron to radon ratio was estimated to be 1.3, higher values were observed in the dwellings than in the offices. The annual effective dose from the exposure to indoor radon was estimated to be 0.47 mSv after taking the occupancy factors of offices and dwellings into account. (author)

  15. Radon measurements with a PIN photodiode

    International Nuclear Information System (INIS)

    Martin-Martin, A.; Gutierrez-Villanueva, J.L.; Munoz, J.M.; Garcia-Talavera, M.; Adamiec, G.; Iniguez, M.P.

    2006-01-01

    Silicon photodiodes are well suited to detect alphas coming from different sources as neutron reactions or radon daughters. In this work a radon in air detecting device, using an 18x18 mm silicon PIN photodiode is studied. The ionized airborne decay products formed during radon diffusion were focused by an accelerating high voltage to the PIN surface. Several conducting rings were disposed inside a cylindrical PVC vessel in such a way that they reproduced the electric field created by a punctual charge located behind PIN position. Alpha spectra coming from the neutral and ionized species deposited on the PIN surface, dominated by 218 Po and 214 Po progeny peaks, were recorded for varying conditions. Those include radon concentration from a Pylon source, high voltage (thousands of volts) and PIN inverse bias voltage. Different parameters such as temperature and humidity were also registered during data acquisition. The increase in the particle collection efficiency with respect to zero electric field was compared with the corresponding to a parallel plates configuration. A discussion is made in terms of the most appropriate voltages for different radon concentrations

  16. The use of track-etch detectors for assessing radon concentrations

    International Nuclear Information System (INIS)

    Kendall, G.M.

    2002-01-01

    The author describes the track-etch dosimetry system used by the National Radiological Protection Board for measuring radon concentrations in dwellings and in workplaces. It also considers the criteria which should be satisfied by an ideal radon dosimetry system aimed at large-scale assessments of the risk from inhalation of radon decay products in room air. The present NRPB track-etch dosimetry system is matched against the requirements of such and ideal system. There is a brief description of the role of screening measurements designed to show whether there are dangerous levels of radon decay products in a house without giving an accurate assessment of their true long-term average concentration

  17. Geologic influence on indoor radon concentrations and gamma radiation levels in Norwegian dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Sundal, Aud Venche

    2003-09-01

    Indoor radon levels in 1618 Norwegian dwellings located in different geological settings were compared with geological information in order to determine potential correlations between geological factors and indoor radon concentrations in Norway and to establish whether geological information is useful in radon risk analysis. In two geographically limited areas, Kinsarvik and Fen, detailed geological and geochemical investigations were carried out in order to explain their elevated natural radiation environment. Significant correlations between geology and indoor radon concentrations in Norway are found when the properties of both the bedrock and the overburden are taken into account. Areas of high radon risk in Norway include 1) exposed bedrock with elevated levels of radium (mainly alum shale and granites) and b) highly permeable unconsolidated sediments derived from all rock types (mainly glaciofluvial and fluvial deposits) and moderately permeable sediments containing radium rich rock fragments (mainly basal till). More than 20 % of Norwegian dwellings located in the high-risk areas can be expected to contain radon levels exceeding 200 Bq/m3. The elevated radon risk related to penneable building grounds is illustrated in Kinsarvik where the highly permeable sediments and the large vadose zone underlying the Huse residential area enable the transport of radon from large volumes into the dwellings resulting in enhanced indoor radon concentrations. Subterranean air flows caused by temperature/pressure differences between soil air and atmospheric air and elevations differences within the Huse area are shown to strongly affect the annual variations in indoor radon concentrations. The marked contrasts in radon risk potential between different types of building grounds are clearly illustrated in the Fen area where outcrops of the radium rich Fen carbonatites represent areas of high radon risk while only low levels of both indoor radon concentrations and indoor gamma

  18. Mitigation of houses with extremely high indoor radon concentrations

    International Nuclear Information System (INIS)

    Jiranek, M.; Neznal, M.

    2006-01-01

    Full text of publication follows: The paper reports on the experience of the Czech Technical University in dealing with mitigation of houses in which unusually high indoor radon concentrations were found. The whole process of remediation is illustrated by example of an old single-family house that was built in the area formed by highly permeable soils with high radon content in the soil air. T he house has a small cellar located under 1/5 of the ground floor area. Two types of floors, i.e. timber floors and cracked concrete slabs were found in the house. As a result of extremely high radon concentration in the sub-floor region (up to 600 kBq/m 3 ) and leaky structures in contact with soil, radon concentrations around 100 kBq/m 3 in the cellar and up to 60 kBq/m 3 in the living rooms on the ground floor were measured prior to mitigation. Mitigation measures that were carried out in the house consist of reconstruction of timber floors and installation of active soil depressurization. Timber floors were replaced with concrete slab fitted with damp proof membrane, thermal insulation and floor covering. The soil depressurization system was made up of two sections. The first section is composed of the network of perforated pipes inserted in the drainage layer placed under the new floors and four perforated tubes drilled under the existing floors. The soil air from this section is extracted by means of a roof fan installed at the top of the vertical exhaust pipe running inside the living space and terminating above the roof. The second section was designed to withdraw by means of a small fan radon-laden air from the filling in the floor above the cellar and from perforated tubes drilled into the sub-floor region under the rooms adjacent to the cellar. It serves also for the active ventilation of the cellar. Pressure, temperature and radon concentration sensors were installed into the drainage layer during the reconstruction of floors to record variations in these

  19. Meteorological factors influencing on the radon concentrations in indoor and outdoor airs

    International Nuclear Information System (INIS)

    Kojima, Hiroshi

    1989-01-01

    Factors influencing radon concentrations in indoor and outdoor airs are discussed. A balance between source and loss is required in determining the radon concentration. Source refers to as the outdoor and indoor exhalation rate from the ground and the building materials. Loss is caused by turbulent diffusion outdoors and ventilation indoors. A significant factor influencing the exhalation rate of indoor and outdoor radon may be the change in atmospheric pressure. A drop of pressure feeds the high concentration air under the ground or building materials into the open air, and contributes to the increased exhalation rate. The exhalation rate of radon closely depends on the moisture content of the ground or building materials. Up to a certain level of moisture, the radon exhalation increases with increasing moisture content because the emanation power increases by a recoil effect of a fluid present in the internal pores of the materials. Beyond a certain level of moisture, the exhalation decreases rapidly because the pores are filled with water. Radon exhalated from the ground is spread out by turbulent diffusion. The turbulent diffusion may be related to wind velocity and the lapse rate of temperature. There is a remakable difference between indoor and outdoor radon concentrations. The ventilation rate of the house exerted a great effect upon the indoor radon concentration. The ventilation rate is influenced by meteorological factors together with human activities. Of such factors, wind velocity and temperature gradient between indoor and outdoor airs may be the most significant. The correlation coefficients between RaA or radon and some meteorological factors were calculated on the data from the long term measurements on radon and its decay products in and out of a house under normal living conditions. The changes in atmospheric pressure and wind velocity are found to be a significant factor in the variation of concentration of these nuclides. (N.K.)

  20. Study of radon progeny distribution and radiation dose rate in the atmosphere

    International Nuclear Information System (INIS)

    Fujinami, Naoto

    2009-01-01

    The absorbed dose rate in air of airborne gamma-ray and the concentration of radon progeny in surface air have been observed continuously in Maizuru, Japan. When data observed on fine days were plotted, with dose rate as ordinate and contraction as abscissa, these points traced with a lapse of time illustrated an anticlockwise looping for each day. This result suggests that the variation of absorbed dose rate lags behind that of concentration of radon progeny; this is due to the delay time incurred as the concentration level gradually varies from ground surface to upper air. Radon progeny concentrations in precipitation and in surface air have been observed there in order to study the relationship between the two concentrations and the influence of precipitation patterns on the concentration in precipitation. Results obtained from analysis of the observed data suggest that radon progeny in precipitation originate mainly from scavenging within the cloud (rainout) and not from that below the cloud (washout). (author)

  1. In-situ potential risk dependence of environmental radon concentration mapping

    International Nuclear Information System (INIS)

    Sajo B, L.; Horvath, A.; Mark, G.; Kasztovszky, Z.; Toth, E.

    1996-01-01

    In this study we present the importance of a close mesh measurements for radon concentration mapping and we demonstrate its necessity when dose calculations are involved. Our results indicate that large errors may be derived from data related to large area mapped with measurements considered characteristic; mean value of a selected region. We point out also that from place to place distant 30 cm radon concentration in the soil at the relaxation depth of 70 cm may differ by a factor of 2 or more. Waters of household wells were monitored also for information on the radon dynamic behaviour. We conclude that for effective dose calculations, particularly in areas with high radon concentration gradient and relatively high population density, the approximate spatial scale variation should be replaced by a systematic dose mesh sampling approach. (authors). 13 refs., 3 figs

  2. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  3. Radon concentration in the springs of the alluvial fan

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi; Kobayashi, Masao

    2003-01-01

    Rokugo alluvial fan is one of the typical stratified alluvial fans which have grown in the east edge of Yokote basin in Akita Prefecture. Many of Rokugo's springs are gushing out from 45 m to 50 m above the sea level where city town have been developed. Mechanism of gushing out of spring is closely bound up with the landform of this area. There is nearly no radon existing in the surface water, but in groundwater, radon concentrations are stable in every stratums and infiltration of groundwater to surface water. We would like to obtain some hydrological information by measuring radon concentration in water samples of Rokugo alluvial fan. (author)

  4. Measurement of radon concentration in air employing Lucas chamber

    International Nuclear Information System (INIS)

    Machaj, B.

    1997-01-01

    The results of investigations aimed to determine the main features of radon concentration gauge in air, employing 0.17 L Lucas chamber, and air sample forced by an air pump are presented. For two hour sampling and measuring cycle time the dynamic error in the worst case (first read out) equals 5 % relative to the step jump of radon concentration. This is due to the increase of activity of the decay products in the chamber. It was observed that the short lived radon decay products (Po-218, Pb-214, Bi-214) are depositing on the walls of the chamber and they are not removed by flushing the chamber with air. (author)

  5. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  6. Indoor radon measurements in south west England explained by topsoil and stream sediment geochemistry, airborne gamma-ray spectroscopy and geology.

    Science.gov (United States)

    Ferreira, Antonio; Daraktchieva, Zornitza; Beamish, David; Kirkwood, Charles; Lister, T Robert; Cave, Mark; Wragg, Joanna; Lee, Kathryn

    2018-01-01

    best result is obtained by including the soil geochemistry with geology and AGR (TSG + G + AGR, ca. 47%). However, adding G and AGR to the TSG model only slightly improves the prediction (ca. +7%), suggesting that the geochemistry of soils already contain most of the information given by geology and airborne datasets together, at least with regard to the explanation of indoor radon. From the present analysis performed in the SW of England, it may be concluded that each one of the four datasets is likely to be useful for radon mapping purposes, whether alone or in combination with others. The present work also suggest that the complete soil geochemistry dataset (TSG) is more effective for indoor radon modelling than using just the U (+Th, K) concentration in soil. Copyright © 2016 Natural Environment Research Council. Published by Elsevier Ltd.. All rights reserved.

  7. Measurements of thoron and radon progeny concentrations in Beijing, China

    International Nuclear Information System (INIS)

    Zhang Lei; Liu Cuihong; Guo Qiuju

    2008-01-01

    It has been reported that thoron levels in China are above the world average and may therefore make a significant contribution to the natural background radiation dose. We therefore conducted a pilot study of concentrations of both thoron and radon progeny during the spring of 2006 in the Beijing area, China. A new type of portable 24 h integrating monitor with a CR-39 detector was used during the survey. Seventy dwellings and eight outdoor sites were measured during the survey. For country houses built of red bricks and slurry, the average equilibrium equivalent concentrations (EEC) of thoron and radon were 1.02 ± 0.48 and 16.41 ± 9.02 Bq m -3 , respectively, whereas for city dwellings built of cement blocks and floor slabs, the results were 0.48 ± 0.47 and 11.50 ± 6.99 Bq m -3 for thoron and radon, respectively. For outdoor air, concentrations of thoron and radon progeny were 0.29 ± 0.28 and 7.05 ± 2.68 Bq m -3 , respectively. Radiation exposures from thoron and radon progeny were also evaluated; the ratio of dose contribution from thoron progeny to that of radon progeny was evaluated to be 28% and 17% in country houses and city dwellings, respectively. (note)

  8. Calculation of radon concentration in water by toluene extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Masaaki [Tokyo Metropolitan Isotope Research Center (Japan)

    1997-02-01

    Noguchi method and Horiuchi method have been used as the calculation method of radon concentration in water. Both methods have two problems in the original, that is, the concentration calculated is changed by the extraction temperature depend on the incorrect solubility data and the concentration calculated are smaller than the correct values, because the radon calculation equation does not true to the gas-liquid equilibrium theory. However, the two problems are solved by improving the radon equation. I presented the Noguchi-Saito equation and the constant B of Horiuchi-Saito equation. The calculating results by the improved method showed about 10% of error. (S.Y.)

  9. Study on calculation models and distribution rules of the radon concentration and its progenies concentration in blind roadway with forced-exhaust ventilation

    International Nuclear Information System (INIS)

    Ye Yongjun; Wang Liheng; Zhou Xinghuo; Li Xiangyang; Zhong Yongming; Wang Shuyun; Ding Dexin

    2014-01-01

    The forced-exhaust ventilation is an important way to control the concentration of radon and its progenies in long-distance blind driving roadway. It is of great significance for guiding the design of ventilation and radiation protection to study distribution characteristics of the concentration of radon and its progenies in the wind of roadway adopting the forced-exhaust ventilation. Therefore, according to the decay relationship of radon and its progenies, a simplified mathematical calculation model was built, which relates to the radon activity concentration and the potential alpha concentration of radon progenies. The paper also analyzed the sources of radon and its progenies in the limited space of the blind roadway. Then, based on the turbulence mass transfer theory of ventilation air flow, the paper established mathematical calculation models of distribution characteristics of the radon activity concentration and the potential alpha concentration of radon progenies in blind roadway with forced-exhaust ventilation, respectively. Finally, the paper applied the calculation models to a special blind roadway, and discussed the influence of the ventilation air inflow and the radon exhalation rate of rock wall on the distribution of radon concentration and the potential alpha concentration of radon progenies in the roadway. Meanwhile, some protective measurements were put forward to reduce the radiation dose of worker caused by radon and its progenies in the blind roadway. (authors)

  10. A comparative study of indoor radon concentrations between dwellings and schools

    International Nuclear Information System (INIS)

    Kapdan, E.; Altinsoy, N.

    2012-01-01

    The aim of this study is to determine the relationship of radon concentrations between dwellings and the schools located in the same regions and to obtain related indoor average radon concentration dwelling–school correction factor for similar locations. The research has been carried out by determining indoor radon concentrations at schools and dwellings located at the same districts in the selected two separate research fields called The Former Adapazari region and The New Adapazari region in the city of Adapazari using a total of 81 Cr-39 passive radon detectors for 75 days. The average radon concentrations have been determined for the dwellings and the schools in 15 districts of the Former Adapazari region as 59.9 Bq m −3 and 57.1 Bq m −3 , respectively. The results in 4 districts of the New Adapazari region were 63.5 Bq m −3 for the dwellings and 61.0 Bq m −3 for the schools. Moreover, the annual effective doses were calculated as 1.33 mSv/y and 1.41 mSv/y for the dwellings of Former Adapazari and New Adapazari, respectively. It was seen that the doses received in the dwellings are about four times the doses received in the schools. The indoor radon concentration dwelling–school correction factor was found to be 1.04±0.01 for the research area.

  11. Mortality and indoor radon daughter concentrations in 13 Canadian cities

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Wigle, D.T.

    1980-01-01

    A study was carried out to determine if lung cancer and general mortality rates in 13 Canadian cities were significantly correlated with average indoor radon daughter concentrations. The radon daughter measurements were obtained from a study of 10,000 homes chosen in a statistically valid grab sample basis. Cancer deaths by year of death, sex, age, and cause were retrieved for each of the cities for the period 1957-1976. Age specific and age standardized mortality rates were calculated. The results showed no evidence of any substantial association between general or lung cancer mortality rates and indoor radon daughter concentrations. The limitations of this study and the feasibility of a common international program of epidemiology of radon daughter exposure are discussed. A proposal is made for the use of case control studies of lung cancer to assess the relative importance of smoking, occupational and domestic exposure to radon daughters

  12. Analysis of the Difference of Radon Concentration between Water Treatment Plant and Tap water in house

    International Nuclear Information System (INIS)

    Seo, Jeongil; Yoo, Donghan; Kim, Heereyoung

    2013-01-01

    As importance for the health, measurements and analysis about radon is active recently. Especially, radon concentration measurement about underground water which people drink was been carried out by the environment organizations in Korea and has been hot-issued because of the high radon concentration in water source. In present study, the difference of radon concentration among water source, water treatment plant and tap water in house is analyzed. It makes sense that the radon concentration in water treatment plant can represent the radon concentration in the tap water. Through the above experiments, the difference of the radon concentration between water treatment plant and tap water in house is figured out. It contributes to confirm more specific basis for estimating the annual radon exposure for the public. With further experiments and analysis, it is thought that it will be used as tool to assess more qualitatively for the radon concentration in tap water. Finally, this Fundamental approach will help in making new regulations about radon

  13. Analysis of the Difference of Radon Concentration between Water Treatment Plant and Tap water in house

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeongil; Yoo, Donghan; Kim, Heereyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2013-05-15

    As importance for the health, measurements and analysis about radon is active recently. Especially, radon concentration measurement about underground water which people drink was been carried out by the environment organizations in Korea and has been hot-issued because of the high radon concentration in water source. In present study, the difference of radon concentration among water source, water treatment plant and tap water in house is analyzed. It makes sense that the radon concentration in water treatment plant can represent the radon concentration in the tap water. Through the above experiments, the difference of the radon concentration between water treatment plant and tap water in house is figured out. It contributes to confirm more specific basis for estimating the annual radon exposure for the public. With further experiments and analysis, it is thought that it will be used as tool to assess more qualitatively for the radon concentration in tap water. Finally, this Fundamental approach will help in making new regulations about radon.

  14. Studies on indoor radon concentrations in Karimanagar district of Telangana State, India

    International Nuclear Information System (INIS)

    Srinivas Reddy, G.; Vinay Kumar Reddy, K.; Sreenivasa Reddy, B.; Ch Gopal Reddy, P.; Yadagiri Reddy, P.; Rama Reddy, K.

    2015-01-01

    Karimnagar district of Telangana state in India falls geologically under the Karimnagar Granulite Terrain (KGT) and, is well known for several types of granites. Studies revealed that the radiation levels are elevated with these granitic rocks. The indoor radon concentrations are estimated in about 80 dwellings, selected randomly in Karimnagar district, using LR-115 Type-II Solid State Nuclear Track Detectors based Twin Chamber Cup dosimeters for a period of one year on quarterly basis. The dose rates due to the radon concentrations are calculated. The seasonal variations of the indoor radon concentrations have been studied. Further, the dependency of indoor radon concentrations on different types of dwellings is also discussed in the present paper. (author)

  15. Concentration ratio of radon progeny in air

    International Nuclear Information System (INIS)

    Kobayashi, Tsuneo

    2000-01-01

    Investigations have been made on the concentration ratio of radon progeny in air. Data have been acquired intermittently since 1988 using alpha spectroscopic method around the author's office that is located in the northeastern part of Japan. Clarifying the behavior of radon progeny is an issue of wide importance to radiation protection, predicting earthquakes, etc. Let Rabc=ECRn(RaA)/{ECRn(RaB) + ECRn(RaC)}; the concentration ratio, Rabc, is relevant to the stability of the air. Statistical and time series analyses indicated several interesting results. To examine the log-normal distribution, Lilliefors test was made for logarithm of outdoor data every one year. Rabc passed the test 6 times for 9 years, while Radon progeny passed 8 times. Outdoor data indicated that the value of Rabc was lower in the morning, in other world, the air was more stable in the morning than in the afternoon. To see the seasonal variation, one-way layout analysis was made for four groups of data, i.e., spring (March to May), summer (June to August), autumn (September to November), and winter (December to February). Rabc indicated significantly higher level in spring and winter, in other word, air was stable in summer and autumn. Time series analysis was made for various variables; power spectra were estimated with autoregressive model that is equivalent to maximum entropy method. Power spectrum for Rabc was most similar to that of wind speed. One-year period, that is always remarkable for radon progeny, was not significant for Rabc. Three- to nine-day periods were often seen for Rabc, radon progeny, wind speed, and atmospheric pressure. These several-day periods are probably attributed to the passage of air masses. Twenty-day to thirty-day peak may be attributed to meteorological phenomena corresponding to the rotation period of the sun. Temperature indicated no significant periodicity except overwhelming one-year period. Wind speed is well known to affect the radon progeny concentration

  16. A study of radon indoor concentration; Un estudio de concentracion de radon intramuros

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G. [ININ, Gerencia de Ciencias Ambientales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m{sup 3} obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  17. Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Jarallah, M. I.; Fazal ur, Rehman

    2006-01-01

    Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia was carried out using passive radon dosemeters. The objective of this radon survey was to obtain representative indoor radon data of Al-Jauf region. The study is a continuation of radon survey in main cities of Saudi Arabia which constitutes a baseline for Saudi Arabia in the Radon World Atlas. A total of 318 passive radon dosemeters were distributed randomly in the region and placed for a period of 1 y starting from April 2004 to April 2005. The results of indoor radon concentration measurement in 136 dwellings distributed in Al-Jauf region are presented. The remaining dosemeters were lost in the dwellings or mishandled. The results showed that the average, minimum, maximum radon concentrations and standard deviation were 35, 7, 168 and 30 Bq m -3 , respectively. Geometric mean and geometric standard deviation of the radon distribution were found to be 28 and 1.83, respectively. (authors)

  18. Calculating flux to predict future cave radon concentrations

    Czech Academy of Sciences Publication Activity Database

    Rowberry, Matthew David; Martí, Xavier; Frontera, C.; Van De Wiel, M.J.; Briestenský, Miloš

    2016-01-01

    Roč. 157, JUN (2016), 16-26 ISSN 0265-931X R&D Projects: GA MŠk LM2010008 Institutional support: RVO:67985891 ; RVO:68378271 Keywords : cave radon concentration * cave radon flux * cave ventilation * radioactive decay * fault slip * numerical modelling Subject RIV: DC - Siesmology, Volcanology, Earth Structure; BG - Nuclear, Atomic and Molecular Physics, Colliders (FZU-D) Impact factor: 2.310, year: 2016

  19. Origin of radon concentration of Csalóka Spring in the Sopron Mountains (West Hungary)

    International Nuclear Information System (INIS)

    Freiler, Ágnes; Horváth, Ákos; Török, Kálmán; Földes, Tamás

    2016-01-01

    We examined the Csalóka Spring, which has the highest radon concentration in the Sopron Mountains (West Hungary) (, yearly average of 227 ± 10 Bq L"−"1). The main rock types here are gneiss and micaschist, formed from metamorphism of former granitic and clastic sedimentary rocks respectively. The aim of the study was to find a likely source of the high radon concentration in water. During two periods (2007–2008 and 2012–2013) water samples were taken from the Csalóka Spring to measure its radon concentration (from 153 ± 9 Bq L"−"1 to 291 ± 15 Bq L"−"1). Soil and rock samples were taken within a 10-m radius of the spring from debrish and from a deformed gneiss outcrop 500 m away from the spring. The radium activity concentration of the samples (between 24.3 ± 2.9 Bq kg"−"1 and 145 ± 6.0 Bq kg"−"1) was measured by gamma-spectroscopy, and the specific radon exhalation was determined using radon-chamber measurements (between 1.32 ± 0.5 Bq kg"−"1 and 37.1 ± 2.2 Bq kg"−"1). Based on these results a model calculation was used to determine the maximum potential radon concentration, which the soil or the rock may provide into the water. We showed that the maximum potential radon concentration of these mylonitic gneissic rocks (c_p_o_t = 2020 Bq L"−"1) is about eight times higher than the measured radon concentration in the water. However the maximum potential radon concentration for soils are significantly lower (41.3 Bq L"−"1) Based on measurements of radon exhalation and porosity of rock and soil samples we concluded that the source material can be the gneiss rock around the spring rather than the soil there. We determined the average radon concentration and the time dependence of the radon concentration over these years in the spring water. We obtained a strong negative correlation (−0.94 in period of 2007–2008 and −0.91 in 2012–2013) between precipitation and radon concentration. - Highlights: • A yearly dataset

  20. Orphan radon daughters at Denver Radium site

    International Nuclear Information System (INIS)

    Holub, R.F.; Droullard, R.F.; Davis, T.H.

    1992-01-01

    During 18 mo of sampling airborne radioactively at a National Priority List (open-quotes Superfundclose quotes) site in metroPOlitan Denver, Bureau of mines personnel discovered radon daughters that are not supported by the parent radon gas. We refer to them as open-quotes orphanclose quotes daughters because the parent, radon, is not present in sufficient concentration to support the measured daughter products. Measurements of the open-quotes orphanclose quotes daughters were made continuously, using the Bureau-developed radon and working-level (radon-daughter) monitors. The data showed high equilibrium ratios, ranging from 0.7 to 3.5, for long periods of time. Repeated, high-volume, 15-min grab samples were made, using the modified Tsivoglou method, to measure radon daughters, to which thoron daughters contributed 26 ± 12%. On average 28 ± 6% of the particulate activity was contributed by thoron daughters. Most samples were mixtures in which the 218 Po concentration was lower than that of 214 Pb and 214 Bi, in agreement with the high-equilibrium factors obtained from the continuous sampling data. In view of the short half-life of radon progeny, we conclude that the source of the orphan daughters is not far from the Superfund sites. The mechanism of this phenomenon is not understood at this time, but we will discuss its possible significance in evaluating population doses

  1. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  2. Concentrations Of Radon In Kindergartens And Schools In Like - Sen And Karlovac Counties

    International Nuclear Information System (INIS)

    Radolic, V.; Stanic, D.; Miklavcic, I.; Poje, M.; Muzevic, M.; Krpan, I.; Vukovic, B.

    2015-01-01

    Measurements of radon concentrations in schools and kindergartens were performed by means of passive, strippable, nuclear track etched detectors LR - 115 type II (Kodak - Pathe, France). The detectors are paired in the way that one detector (open detector), placed on the circumferential side of the plastic detector vessel, registers total number of alpha particles from radon and its short-lived progenies. At the same time, the other detector (diffusion detector) is placed inside the vessel and it registers only alpha particles emitted by radon. The average radon concentrations in kindergartens and schools of Lika-Senj County are 318 and 317 Bq m -3 while for Karlovac County they are 228 and 304 Bq m -3 respectively. Moreover, there are three schools in Karlovac County with the average radon concentration higher than 1000 Bq m -3 , which represents the action level for intervention measures in Croatia. Even more, there are 2.5 percent of rooms in kindergartens and 4 percent of rooms in schools in Lika - Senj County with measured radon concentrations higher than 1000 Bq m -3 . In Karlovac County there are 2.4 percent of such rooms in kindergartens and 7 percent in schools. Maps of spatial distribution of indoor radon concentrations for homes as well as for kindergartens and schools were created by using the Inverse Distance Weighting interpolation method. This is one of the useful methods for identifying radon prone areas. The authors propose a repetition of measurements in those kindergartens, schools and homes with higher radon concentrations in coordination with the local government. (author).

  3. Carcinogenic risk associated with radon-enriched well water

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.

    1997-01-01

    A comparison has been made between radon in drinking water and the incidence of cancer using a set of home occupants in Virginia and Maryland. In a subset of people who drink radon-free but chlorinated drinking water from a reservoir, about 3% develop some type of cancer. In a subset of people who drink low-radon water from private water wells, about 3% develop cancer. In a subset who drink high-radon well water, about 6% develop cancer. A comparison with Environmental Protection Agency (EPA) estimates of cancer related to airborne radon indicates that for the general population, the incidence of radon-related cancer from drinking water is similar to the incidence of cancer from inhaled radon. For the 10% of the population that consumes well water and, in particular, for the 5% of the population that consumes high-radon well water, the drinking water carries a considerably higher cancer risk than inhaling airborne radon

  4. Long-term variation of outdoor radon equilibrium equivalent concentration

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H. [GSF-Forschungszentrum fuer Umwelt und Gesundheit, Inst. fuer Strahlenschutz, Oberschleissheim (Germany); Winkler, R. [GSF-Forschungszentrum fuer Umwelt und Gesundheit, Inst. fuer Strahlenschutz, Oberschleissheim (Germany)

    1994-10-01

    Long-term variation of outdoor radon equilibrium equivalent concentration was investigated from 1982 to 1992 at a semi-natural location 10 km north of Munich, southern Germany. For this period the continuous measurement yielded a long-term average of 8.6 Bq.m{sup -3} (arithmetic mean) and 6.9 Bq.m{sup -3} (geometric mean), from which an average annual effective dose of 0.14 mSv due to outdoor radon can be derived. A long-term trend of the radon concentration was not detectable over the whole period of observation. However, by time series analysis, a long-term cyclic pattern was identified with two maxima (1984-1986, 1989-1991) and two minima (1982-1983, 1987-1988). The seasonal pattern is characterized by an autumn maximum and an early summer minimum. On average, the seasonal maximum in October was found to be higher by a factor of 2 than the June minimum. The diurnal variation of the radon concentration shows a maximum in the early morning and a minimum in the afternoon. On average, this maximum is a factor of 2 higher than the minimum. In the long term a seasonal pattern was observed for diurnal variation, with an average diurnal maximum to minimum ratio of 1.5 in winter compared with 3.5 in the summer months. The radon concentration is correlated with a meteorological parameter (stagnation index) which takes into account horizontal and vertical exchange processes and the wash-out of aerosols in the lower atmosphere. (orig.)

  5. Long-term variation of outdoor radon equilibrium equivalent concentration

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1994-01-01

    Long-term variation of outdoor radon equilibrium equivalent concentration was investigated from 1982 to 1992 at a semi-natural location 10 km north of Munich, southern Germany. For this period the continuous measurement yielded a long-term average of 8.6 Bq.m -3 (arithmetic mean) and 6.9 Bq.m -3 (geometric mean), from which an average annual effective dose of 0.14 mSv due to outdoor radon can be derived. A long-term trend of the radon concentration was not detectable over the whole period of observation. However, by time series analysis, a long-term cyclic pattern was identified with two maxima (1984-1986, 1989-1991) and two minima (1982-1983, 1987-1988). The seasonal pattern is characterized by an autumn maximum and an early summer minimum. On average, the seasonal maximum in October was found to be higher by a factor of 2 than the June minimum. The diurnal variation of the radon concentration shows a maximum in the early morning and a minimum in the afternoon. On average, this maximum is a factor of 2 higher than the minimum. In the long term a seasonal pattern was observed for diurnal variation, with an average diurnal maximum to minimum ratio of 1.5 in winter compared with 3.5 in the summer months. The radon concentration is correlated with a meteorological parameter (stagnation index) which takes into account horizontal and vertical exchange processes and the wash-out of aerosols in the lower atmosphere. (orig.)

  6. Radon in a Karstic Region School: Concentrations in Soil Gas and Indoors

    International Nuclear Information System (INIS)

    Vaupotic, J.; Kobal, I.; Barisic, D.; Lulic, S.

    1998-01-01

    The school presented in this paper exceeded instantaneous indoor radon concentration of 1000 Bqm -3 , obtained within the Slovene radon programme. Thus, additional measurements were performed and the radiation doses of teachers and pupils estimated. Radon concentrations between 1000 and 3000 Bqm -3 during teaching hours were found and the yearly effective doses from 0.75 to 1.1 mSv for the pupils and from 1.1 to 4.2 mSv for the teachers were calculated. In the soil gas radon and thoron concentration ranging from 70 to 150 kBqm -3 were obtained. The school was mitigated during summer 1998. (author)

  7. Developing an interactive computational system to simulate radon concentration inside ancient egyptian tombs

    Energy Technology Data Exchange (ETDEWEB)

    Metwally, S M; Salama, E; El-Fikia, S A [Faculty of Science, Department of Physics, Ain Shams University, P. O. Box 11566, Cairo (Egypt); Abo-EImagd, M; Eissa, H M [National Institute for Standard, Radiation Measurements Department, P. O. Box 136Giza code no. 12211 RSSP (Egypt)

    2007-06-15

    RSSP (Radon Scale Software Package) is an interactive support system that simulates the radon concentration inside ancient Egyptian tombs and the consequences on the population in terms of internal and external exposure. RSSP consists of three interconnected modules: the first one simulates the radon concentration inside ancient Egyptian tombs using a developed mathematical model. This model introduces the possibility of controlling the rate of radon accumulation via additional artificial ventilation systems. The source of inputs is an editable database for the tombs includes the geometrical dimensions and some environmental parameters like temperature and outdoor radon concentration at the tombs locations. The second module simulates the absorbed dose due to internal exposure of radon and its progeny. The third module simulates the absorbed dose due to external exposure of Gamma rays emitted from the tomb wall rocks. RSSP introduces the facility of following the progress of radon concentration as well as Internal and external absorbed dose in a wide range of time (seconds, minutes, hours and days) via numerical data and the corresponding graphical interface.

  8. Developing an interactive computational system to simulate radon concentration inside ancient egyptian tombs

    International Nuclear Information System (INIS)

    Metwally, S. M.; Salama, E.; El-Fikia, S. A.; Abo-EImagd, M.; Eissa, H. M.

    2007-01-01

    RSSP (Radon Scale Software Package) is an interactive support system that simulates the radon concentration inside ancient Egyptian tombs and the consequences on the population in terms of internal and external exposure. RSSP consists of three interconnected modules: the first one simulates the radon concentration inside ancient Egyptian tombs using a developed mathematical model. This model introduces the possibility of controlling the rate of radon accumulation via additional artificial ventilation systems. The source of inputs is an editable database for the tombs includes the geometrical dimensions and some environmental parameters like temperature and outdoor radon concentration at the tombs locations. The second module simulates the absorbed dose due to internal exposure of radon and its progeny. The third module simulates the absorbed dose due to external exposure of Gamma rays emitted from the tomb wall rocks. RSSP introduces the facility of following the progress of radon concentration as well as Internal and external absorbed dose in a wide range of time (seconds, minutes, hours and days) via numerical data and the corresponding graphical interface

  9. Mapping of groundwater radon potential

    International Nuclear Information System (INIS)

    Aekerblom, G.; Lindgren, J.

    1997-01-01

    The domestic use of water with elevated radon concentration may represent a public health hazard, partly due to the release of radon to the indoor air. While only a limited number of countries have implemented regulations with respect to radon in water, many more are considering doing so. The compulsory limits proposed by Swedish authorities are 100 Bq/1 for public water, while water from private wells is not to exceed 1000 Bq/1. Furthermore, it is recommended that water with a radon content above 500 Bq/1 should not be given to children under five years of age. In Sweden, the estimated number of wells with radon levels above 1000 Bq/1 exceeds 10,000, with a considerable amount in excess of 10,000 Bq/1. The highest radon concentration in a well supplying drinking water encountered so far is 57,000 Bq/1. Radon levels exceeding 500 Bq/1 are almost exclusively found in wells drilled into bedrock and in springs with intramontaneous water. Elevated ground water radon levels require that the water has passed through bedrock with elevated concentration of uranium, or through fractures with coatings of minerals containing enhanced concentrations of radium-226. Intramontaneous water from areas with uranium-bearing rock types (e.g. uranium-rich granites, pegmatites and vulcanites) often manifests elevated radon levels. Routines for the establishment of risk maps focusing on water are currently under development. The backbone of the process is the access to high spatial resolution radiometric information together with bedrock and soil information on a detailed scale (1:50,000). This information is available from the Geological Survey of Sweden, which is routinely carrying out airborne measurements at an altitude of 30 m and a line spacing of 200 m. While some 60% of Sweden is covered up to now, 75 % is expected to be covered within the next ten years. Other available databases utilized in the risk mapping process include radon measurements in wells, geochemical data from

  10. Influences on indoor radon concentrations in Riyadh, Saudi Arabia

    International Nuclear Information System (INIS)

    Alghamdi, Abdulrahman S.; Aleissa, Khalid A.

    2014-01-01

    The influences on indoor radon concentrations in Riyadh, Saudi Arabia survey was carried out for 786 dwellings. The measurements were obtained by using a passive integrating ionization system with an E-Perm ® Electret ion chamber. Radon levels ranged from 1 to 195 Bq m −3 , with a mean value of 24.68 Bq m −3 , the geometric mean and the geometric standard deviation are 21 and 2 respectively. 98.5% of the results were below the action level recommended by WHO of 100 Bq.m −3 . The results were found to vary substantially due to types of houses and rooms, ventilation, seasons and building materials. Radon concentrations were higher in houses with no ventilation systems, and central air conditioners, and were relatively lower in well ventilated houses with red bricks and water air conditioners. - Highlights: • Limited information about indoor radon in Riyadh. • Several factors influence Radon level were investigated in 786 dwellings in Riyadh over one year. • Some results are over the action level and are advised to improve their ventilation systems

  11. Radon Concentration in Outdoors and Indoors Around the Flare in Oil Mine Sites

    International Nuclear Information System (INIS)

    Sutarman; Wahyudi; Luhantara

    2003-01-01

    The flares are much found at the oil exploration areas which appear the combustion gases emission to the environment that pass through a pipe at about 8 m high from the ground level. The flare is released into the environment together with the hydrocarbon and radon gases. This study has been carried out the measurement of the radon gas concentration only. Radon is a radioactive gas which comes from the natural radioactive decay of uranium ( 238 U). The outdoor radon concentrations were measured in 23 locations with the two-filter method. The locations were determined by a circle which the flare as the point center. The outdoor radon concentrations were measured in 74 houses (more than distance of 600 m from the flare) with the alpha track detector (CR-39) placed in the living rooms for about three months. The measurements of the radon concentrations were carried out in Cepu, Cirebon, and Prabumulih oil mine sites. The results showed that the outdoor radon concentrations a range of 108 Bq/m 3 to 256 Bq/m 3 in Cepu, 248 Bq/m 3 to 3525 Bq/m 3 in Cirebon, and 51 Bq/m 3 to 114 Bq/m 3 in Prabumulih. The results showed that the indoor radon concentrations a range of 11 Bq/m 3 to 38 Bq/m 3 in Cepu, 28 Bq/m 3 to 184 Bq/m 3 in Cirebon, and 12 Bq/m 3 to 38 Bq/m 3 in Prabumulih. The data of the maximum radon concentration in outdoor air was higher than an actual level which recommended by International Atomic Energy Agency (IAEA) for workplaces. The maximum radon concentration in indoor air was lower than an actual level which recommended by IAEA for dwellings. IAEA recommends the actual level of 1000 Bq/m 3 for workplaces and 200 Bq/m 3 for dwellings. These data will be used for the baseline data of the environmental radioactivity in Indonesia. (author)

  12. Seasonal variation in concentration of radon and thoron at non-uranium mines in China

    International Nuclear Information System (INIS)

    Cui Hongxing; Wu Yunyun; Zhang Qingzhao; Shang Bing

    2009-01-01

    Objective: To study the seasonal variation in concentrations of radon and thoron in non-uranium mine. Methods: Eight kinds of mineral types from 9 non-uranium mines were selected, including copper, gold, aluminium, manganese, antimonium, tungsten, copper-nickel and coal mines in 6 provinces, such as Yunnan, Shandong, Xinjiang, Heilongjiang, Hunan and Guizhou. LD-P R-T discriminative detectors were used to measure radon and thoron concentrations in underground mines during four seasons in one year. Results: Radon concentrations in underground mines showed a significantly seasonal variation. Radon concentration ranged from 35.5 to 4841 Bq/m 3 in summer, and the average value in four mines exceeded 1000 Bq/m 3 of the control limit for workplace (GB 18871-2002) . In winter, radon concentration ranged from 5 to 1917 Bq/m 3 , only one of them exceeded the control limit. The ratio of radon from summer to winter ranged from 2 to 12. Ventilation was one of the main factors which influenced the seasonal variation of radon. While the thoron concentration in underground mines showed a tendency that it was higher in summer and lower in winter. It was difficult to attain representative values for thoron, due to the influence of location of detectors. The seasonal variation of thoron should be further studied. Conclusions: Seasonal variation for radon and thoron should be taken into account to estimate the effective dose to miners. The values of radon concentration during the short term should be corrected. (authors)

  13. The study of thoron and radon progeny concentrations in dwellings in Japan

    International Nuclear Information System (INIS)

    Guo, Q.; Shimo, M.; Ikebe, Y.

    1992-01-01

    Ths paper aims to make a comparison of different concentrations of thoron ( 220 Rn) progeny and radon ( 222 Rn) progeny in different kinds of dwellings. The potential alpha energy concentrations and the effective dose equivalent caused by thoron and radon progeny, respectively, have also been estimated. The measurements were carried out in 23 dwellings. The results indicate that thoron progeny concentrations indoors might be strongly affected by the type of building material used. Traditional Japanese buildings made with mud may have high thoron progeny concentrations of about 3.52 Bq.m -3 and a concentration ratio of thoron progeny to radon progeny of about 0.5, whereas in concrete dwellings thoron progeny concentrations are about 0.72 Bq.m -3 and the concentration ratio of thoron progeny to radon progeny is about 0.1. The annual effective dose equivalent of thoron progeny is 1.23 mSv in mud dwellings and 0.25 mSv in concrete dwellings. (author)

  14. Predictors of Airborne Endotoxin Concentrations in Inner City Homes

    Science.gov (United States)

    Mazique, D; Diette, GB; Breysse, PN; Matsui, EC; McCormack, MC; Curtin-Brosnan, J; Williams, D; Peng, RD; Hansel, NN

    2011-01-01

    Few studies have assessed in-home factors which contribute to airborne endotoxin concentrations. In 85 inner-city Baltimore homes, we found no significant correlation between settled dust and airborne endotoxin concentrations. Certain household activities and characteristics, including frequency of dusting, air conditioner use and type of flooring, explained 36–42% of the variability of airborne concentrations. Measurements of both airborne and settled dust endotoxin concentrations may be needed to fully characterize domestic exposure in epidemiologic investigations. PMID:21429483

  15. Relation between residential radon concentrations and housing characteristics. The Cracow study

    International Nuclear Information System (INIS)

    Jedrychowski, W.; Flak, E.; Wesolowski, J.; Liu Kaishen

    1995-01-01

    The survey on indoor radon exposure was undertaken to explain whether the excess in lung cancer deaths in the Cracow city center may be attributed to this particular exposure. A total of 310 detectors was placed in households randomly chosen from three homogeneous strata of residential buildings. The first stratum included houses in the old city center constructed predominantly from stone bricks. The second stratum covered the city area with big apartment condominiums built from concrete blocks. The third stratum consisted of single family houses located in a suburban area. From each of these residency strata a random sample of an equal number of households was chosen, and the radon detectors were placed in households located at various levels of the buildings. The three-month radon sampling data were used to determine the distribution of various levels of radon in the households. In the measurement of radon exposure, Landauer α-track samplers were used. The data collected show that the type of building was the best single predictor of indoor radon concentrations. Other variables found to be associated significantly with indoor concentrations were the household level in the building and the house age. In general, residences with concrete slabs and dwellings with rarely-opened windows were found to have slightly higher radon concentrations. (author) 2 tabs., 15 refs

  16. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  17. Radon concentrations in residential housing in hiroshima and nagasaki

    International Nuclear Information System (INIS)

    Aoyama, Takashi; Radford, E.P.; Yonehara, Hidenori; Kato, Hiroo; Sakanoue, Masanobu.

    1993-05-01

    A survey of indoor radon ( 222 Rn) concentrations in Hiroshima and Nagasaki was carried out to assess the range of exposures expected among atomic-bomb survivors. Two hundred dwellings (100 from each city), chiefly of members of the Radiation Effects Research Foundation Life Span Study, were selected for this survey. We used two types of etched-track alpha-particle detectors: a Terradex detector (type SF) and an improved bare-track detector. Comparative measurements showed that although there was an adequate correlation between the values obtained using the two detectors, the geometric mean value for the bare-track detector was 45% lower than that for the Terradex detector. This difference was considered to be due to differences in the calibration methods and in the sensitivities of the detectors to thoron ( 220 Rn). The geometric mean values of the radon concentrations for 193 locations in Hiroshima and 192 locations in Nagasaki measured by Terradex SF detectors were 51.8 Bq/m 3 and 26.5 Bq/m 3 , respectively. The large difference is attributable to the different geological environments of the two cities. Factors correlating with the indoor radon concentrations were also studied. The geometric mean concentration was significantly higher in wooden houses with clay walls than in other types of house. This tendency was especially strong in Hiroshima. The difference between the estimated dose equivalents for exposure to radon decay products in dwellings in Hiroshima and Nagasaki during the last 30 years might amount to 0.8 Sv; however, no statistically significant difference was observed in lung-cancer mortality in the low-dose range in either city. Nevertheless, the indoor radon concentrations estimated in this survey could have a significant influence on the dose-response relationship for atomic-bomb exposure. (author)

  18. Risk assessment of radon gas concentration for some selected offices of KNUST campus, Kumasi

    International Nuclear Information System (INIS)

    Bediako, Yaw Addo

    2013-11-01

    Radon (Rn-222) has been identified as an factor that could result in a health hazard by studies all around the world. The health risks can be minimised by preventing measures where radon is highly concentrated as in some mines or homes or offices. A study in the buildup concentration of the inert gas, will give us a better understanding of its possible pathways through soil into the air surrounding and offices where radon releases can become hazardous. Measuring the radon concentrations on campus, can help to deduce the radon flux to identify the problem areas for rehabilitation. An active method incorporating Trace level radon gas detection and continious monitoring method was used in this study to determine the radon concentration of the selected offices. Concentrations ranging from 0.010 to 0.498 pCi/I were detected, with the head of optometry and Visual Science recording the highest concentration of 0.498 pCi/I, while the head of Agricultural Engineering Department office with the least concentration of 0.010 pCi/I. Although these concentrations are generally low as compared with the EPA guidelines of an action level of 4 pCi/I, but no amount of radiation is said to be safe. (au)

  19. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Science.gov (United States)

    Wu, Yun-Yun; Ma, Yong-Zhong; Cui, Hong-Xing; Liu, Jian-Xiang; Sun, Ya-Ru; Shang, Bing; Su, Xu

    2014-01-01

    222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration. PMID:25350007

  20. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Directory of Open Access Journals (Sweden)

    Yun-Yun Wu

    2014-10-01

    Full Text Available 222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration.

  1. Measurement of radon concentration in Taiz city dwellings-yemen

    International Nuclear Information System (INIS)

    Ali, Taher M.; Ahmed, Hayel A.; Ismail, Rokhsana M.

    2001-01-01

    Radon gas considered being a high part of natural radiation background. Emitting alpha particles; radon daughters may be deposited into the lungs and cause health hazards. For this reason, estimation of radon levels in dwellings was done in many countries. In our country, Radon group in the Department of physics, University of Aden has been studied radon level in Aden dwelling. The present study is about the radon level in Taiz City - Yemen. Passive diffusion dosimeters containing (SSNTD s ) Cr - 39 detectors were used in the present work. 125 dosimeters were distributed into dwellings of ten regions in Taiz City. Results obtained show that Rn 222 levels vary between 4 Bq/m 3 and 99 Bq/m 3 . The average concentration in Al-Hasseb district is 23 Bq/m 3 and in Algumhuri hospital district is 53 Bq/m 3 . In other regions it varies between the two values. Whereas the general average in the Taiz City is 34 Bq/m 3 . (author)

  2. Correlation of radon and thoron concentrations with natural radioactivity of soil in Zonguldak, Turkey

    Science.gov (United States)

    Koray, Abdullah; Akkaya, Gizem; Kahraman, Ayşegül

    2017-02-01

    Radon and thoron gases are produced by the decay of the radioactive elements those are radium and thorium in the soil. In this study, the correlations between soil radon and thoron concentration with their parent nuclide (226Ra and 232Th) concentrations in collected soil samples from the same locations were evaluated. The result of the measurement shows that the distribution of radon and thoron in soil showed the same tendency as 226Ra and 232Th distribution. It was found a weak correlation between the radon and the 226Ra concentration (R =0.57), and between the thoron and the 232Th concentration (R=0.64). No strong correlation was observed between soil-gas radon and thoron concentration (R = 0.29).

  3. Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-01-01

    This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes.

  4. Radon concentrations in contaminated and uncontaminated premises in two Ontario towns

    International Nuclear Information System (INIS)

    Aitken, J.H.; Baker, E.G.; Chatterjee, R.M.; Kusiak, R.; Tai-Pow, J.

    1977-01-01

    Radon-222 concentrations in air were measured by grab sampling in a large number of private homes and other buildings in the town of Port Hope, Ontario. The purpose of the measurements is to identify places where a health hazard might exist due to improper disposal of radium-contaminated materials. Contaminated fill, rubble, lumber, and other building materials have been found in a number of premises in the town. Radon concentrations up to 750 pCi/l have been found in some homes. The thrust of the program is to identify quickly places where concentrations might be high enough to justify some prompt interim remedial action such as installation of special ventilation systems, pending final remedial work by removal of the contamination. The methods and instrumentation immediately available are those formerly used for radon-in-breath analysis in radium workers. Grab sampling for radon and gamma surveying in every building in town are used together in a screening program. Experience showed that both radon sampling and gamma surveying are required to identify contaminated locations

  5. Daily variation of the radon concentration indoors and outdoors and the influence of meteorological parameters

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Butterweck, G.; Reineking, A.

    1994-01-01

    Series of continuous radon measurements in the open atmosphere and in a dwelling, including the parallel measurement of meteorological parameters, were performed over a period of several weeks. The radon concentration in indoor and outdoor air depends on meteorological conditions. In the open atmosphere the radon concentration varies between 1 and 100 Bq m -3 , depending on weather conditions and time of day. During time periods of low turbulent air exchange (high pressure weather with clear night sky), especially in the night and early morning hours (night inversion layer), the diurnal variation of the radon concentration showed a pronounced maximum. Cloudy and windy weather conditions yield a small diurnal variation of the radon concentration. Indoors, the average level and the diurnal variation of the indoor radon concentration is also influenced by meteorological conditions. The measurements are consistent with a dependence of indoor radon concentrations on indoor-outdoor pressure differences. 11 refs., 4 figs

  6. On the possibility of detecting peaks of radon concentration in working areas

    International Nuclear Information System (INIS)

    Madelaine, G.; Zettwoog, P.

    1979-01-01

    Four methods for the continuous measurement of radon concentration, are described. The first two are based on the measurement of the ionization produced by the gas α disintegration. The third one carries out scintillation measurement of radon present in a chamber. The fourth is based on the disintegration chamber principle. Concerning the possibility of detecting radon concentration peaks, the use of ionization detectors, after a feasibility study seems to be suitable

  7. Methodology developed to make the Quebec indoor radon potential map

    International Nuclear Information System (INIS)

    Drolet, Jean-Philippe; Martel, Richard; Poulin, Patrick; Dessau, Jean-Claude

    2014-01-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m 3 in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for each

  8. Measurements of the radon-222 and its daughters concentrations throughout Gaza strip, Palestine

    International Nuclear Information System (INIS)

    Rasas, M.F.; Yassin, S.S.; Shabat, M.M.

    2005-01-01

    High Radon levels are present in the granite and grandiositic rocks that. spread in sand dunes along coast of Gaza. Such materials are rich in uranium and T widely used in the construction of dwelling in the Gaza, and their contribution to high indoor Radon levels is most relevant.The present work aims to investigate approaches, measures and detection of indoor Radon level throughout Gaza Strip. Five hundred CR-39 dosimeters were distributed over six locations in the middle Yv-region of Gaza Strip. Results suggest that Radon concentrations range from l3.36 to 83.82 Bq/m 3 and a maximum value of 97.01 Bq/m 3 .The average Radon concentrations was 37.83 Bq/m 3 with standard deviation of 11.23.The results provide a framework for future studies that include a large, broader survey of Radon concentration in Palestine

  9. Analysis of atmospheric concentrations of radon and thoron using beta counting technique

    International Nuclear Information System (INIS)

    Islam, G.S.; Basunia, S.M.

    1995-05-01

    This paper presents a detailed theory and experimental procedure for measurement and analysis of mixed radon and thoron in the environment. The technique has been successfully applied to the study of seasonal variations of radon and thoron in Rajshahi atmosphere during the years 1989-1991. The maximum radon concentration in outdoor air was observed in the winter from December to January while the indoor radon concentration was found to be maximum during the monsoon months of July and August. The implication of results is briefly discussed in the paper. (author). 4 refs, 6 figs, 2 tabs

  10. Comparison of five-minute radon-daughter measurements with long-term radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1983-01-01

    Five-minute air filter radon daughter measurements were made in 84 buildings in Edgemont, South Dakota, in which annual average radon daughter concentrations have been determined from six 100-hour Radon Progeny Integrating Sampling Unit (RPISU) measurements. Averaging radon concentrations were also determined in 50 of these buildings using Terradex Track Etch detectors. The standard deviation of the difference between the (natural) logarithms of the RPISU annual averages and the logarithms of the air filter measurements (SD-ln) was found to be 0.52. This SD-ln is considerably smaller than the SD-ln of 0.71 between the RPISU annual averages and the air filter measurements reported by ALARA at Grand Junction, Colorado; presumably because a considerable number of air filter measurements in Edgemont were disregarded because of short turnover times or high wind speeds. Using the SD-ln of 0.52 it can be calculated that there would only be a 5% probability in Edgemont that the RPISU annual average would be greater than 0.015 WL if the five-minute measurement were equal to 0.010 WL. This indicates that the procedure used in Edgemont of clearing buildings from remedial action if the five-minute measurement were less than 0.010 WL was reasonable. There was about a 28% probability that the RPISU annual average would be less than 0.015 WL if the five-minute measurement were 0.033 WL, indicating that the procedure of performing an engineering assessment if the average of two five-minute measurements was greater than 0.033 WL was also reasonable. Comparison indicates that the average of two RPISU measurements taken six months apart would provide a dependable estimate of the annual average

  11. The reduction of airborne radon daughter concentration by plateout on an air mixing fan

    International Nuclear Information System (INIS)

    Holub, R.F.; Droullard, R.F.; Ho, W.L.; Hopke, P.K.; Parsley, R.; Stukel, J.J.

    1979-01-01

    A series of experiments have been made in the U.S. Bureau of Mines Radon Test Chamber to study the effects of condensation nuclei, humidity and turbulence on the rapid deposition or plateout of radon daughter activity on the chamber walls. Under low humidity conditions the presence of a small fan reduced the working level by 41%. The activity was not deposited on the walls by the turbulent flow from the fan but actually became attached to the fan blades. High relative humidity (> 80%) totally inhibited this observed effect. A detailed mechanism for transport of the daughter species seems to be the critical factor in interpreting the experimental results. (author)

  12. Final report of evaluation of dose and measurement of radon concentration

    International Nuclear Information System (INIS)

    1998-03-01

    A mean annual exposure to radon daughters in indoor air was estimated on the basis of measurement of radon concentration in indoor air in Japan from fiscal 1992 to 1996. Doses were estimated by UNSCEAR method. The representative values in this report show the mean values in whole Japan. Each dose in the local area was different reflecting the different concentration of radon daughters. However, the same parameters were used in each area. When mean annual dose of radon daughters was estimated, we used 15.5 Bq m -3 mean annual exposure to radon daughters in indoor air, 5 Bq m -3 that in outdoor air, 0.4 the equilibrium factor indoor, 0.6 the equilibrium factor outdoor and 0.9 of P. The model of UNSCEAR based on these above values gave 0.46 mSv y -1 mean annual dose of radon daughters which were consisted of from 0.38 mSv y -1 in Kanto district to 0.52 mSv y -1 Kyushu, Okinawa district. (S.Y.)

  13. Final report of evaluation of dose and measurement of radon concentration

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    A mean annual exposure to radon daughters in indoor air was estimated on the basis of measurement of radon concentration in indoor air in Japan from fiscal 1992 to 1996. Doses were estimated by UNSCEAR method. The representative values in this report show the mean values in whole Japan. Each dose in the local area was different reflecting the different concentration of radon daughters. However, the same parameters were used in each area. When mean annual dose of radon daughters was estimated, we used 15.5 Bq m{sup -3} mean annual exposure to radon daughters in indoor air, 5 Bq m{sup -3} that in outdoor air, 0.4 the equilibrium factor indoor, 0.6 the equilibrium factor outdoor and 0.9 of P. The model of UNSCEAR based on these above values gave 0.46 mSv y{sup -1} mean annual dose of radon daughters which were consisted of from 0.38 mSv y{sup -1} in Kanto district to 0.52 mSv y{sup -1} Kyushu, Okinawa district. (S.Y.)

  14. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  15. Measurement of radon activity concentrations in air of Tuzla city

    International Nuclear Information System (INIS)

    Adrovic, F.; Fazlic, R.; Tresnjo, Z.

    2004-01-01

    The survey was conducted over one year in the area of Tuzla city and its surrounding. At the measuring locations there were registered Daily and seasonal variations in outdoor radon concentration were observed, with average values lying within the region of 9 - 30 Bq/m 3 . The results of the measurements will be included in the concentration map of radon activity in Bosnia and Herzegovina, which is under preparation. (P.A.)

  16. Estimation of radon concentration in dwellings in and around ...

    Indian Academy of Sciences (India)

    Besides, it is also known that out of the total radiation dose received from natural and man-made sources, 60% of the dose is due to radon and its progeny. Taking this into account, an attempt has been made to estimate radon concentration in dwellings in and around Guwahati using aluminium dosimeter cups with CR-39 ...

  17. Measurement of indoor radon Concentrations in Osaka, Nara, Wakayama and Hyogo with passive dosemeters

    International Nuclear Information System (INIS)

    Mori, Toshiaki; Hori, Yasuharu; Takeda, Atsuhiko; Iwasaki, Tamiko; Uchiyama, Masahumi; Fujimoto, Kenzo; Kankura, Takako; Kobayashi, Sadayosi.

    1989-01-01

    Indoor radon concentrations of 792 houses in Osaka, Nara, Wakayama and Hyogo were measured by the passive dosemeter which was developed in Karlsruhe Nuclear Research Center in West Germany. Each house was measured at two places for successive two periods of six months to obtain annual average exposure due to radon daughters. The arithmetic mean concentration of all houses was 45.2 Bq/m 3 with a standard deviation of 27.2; the geometric mean, 40.7 Bq/m 3 and the median, 39 Bq/m 3 . The distribution of the radon levels was approximately log-normal with 80% of houses having radon concentrations less than 60 Bq/m 3 . The seasonal variation of the mean radon concentration was evident between the former period including winter value of 45 Bq/m 3 and the latter including summer value of 32 Bq/m 3 . The indoor radon concentrations of wooden houses were found to have the widest distribution with the highest value of 371 Bq/m 3 . The highest value obtained in the ferro-concrete house was 118 Bq/m 3 . Twelve houses having indoor radon concentrations higher than 120 Bq/m 3 were all Japanese traditional wooden houses with walls made of soil. (author)

  18. Distance to faults as a proxy for radon gas concentration in dwellings.

    Science.gov (United States)

    Drolet, Jean-Philippe; Martel, Richard

    2016-02-01

    This research was done to demonstrate the usefulness of the local structural geology characteristics to predict indoor radon concentrations. The presence of geologic faults near dwellings increases the vulnerability of the dwellings to elevated indoor radon by providing favorable pathways from the source uranium-rich bedrock units to the surface. Kruskal-Wallis one-way analyses of variance by ranks were used to determine the distance where faults have statistically significant influence on indoor radon concentrations. The great-circle distance between the 640 spatially referenced basement radon concentration measurements and the nearest fault was calculated using the Haversine formula and the spherical law of cosines. It was shown that dwellings located less than 150 m from a major fault had a higher radon potential. The 150 m threshold was determined using Kruskal-Wallis ANOVA on: (1) all the basement radon measurements dataset and; (2) the basement radon measurements located on uranium-rich bedrock units only. The results indicated that 22.8% of the dwellings located less than 150 m from a fault exceeded the Canadian radon guideline of 200 Bq/m(3) when using all the basement radon measurements dataset. This percentage fell to 15.2% for the dwellings located between 150 m and 700 m from a fault. When using only the basement radon measurements located on uranium-rich bedrock units, these percentages were 30.7% (0-150 m) and 17.5% (150 m-700 m). The assessment and management of risk can be improved where structural geology characteristics base maps are available by using this proxy indicator. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector

    International Nuclear Information System (INIS)

    Bastrikov, V.; Kruzhalov, A.; Zhukovsky, M.

    2006-01-01

    The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as α-particle detector and as absorber decreasing the energy of α-particles. The uncertainties of implanted 210 Pb measurements by two- and three-layer detectors are assessed in dependence on surface 210 Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from 210 Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached 218 Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ratio, air exchange rate and aerosol particles concentration the systematic bias of conversion coefficient between surface activity of 210 Po and average radon concentration can be decreased up to 30 %. (N.C.)

  20. Determination of radon and progeny concentrations in Brazilian underground mines

    International Nuclear Information System (INIS)

    Fraenkel, Mario O.; Gouvea, Vandir de Azevedo; Macacini, Jose F.; Cardozo, Katia; Carvalho Filho, Carlos A. de; Lima, Carlos E.

    2008-01-01

    The aim of this work is to present the activities related to the determination of radon and progeny concentrations in underground mines in Brazil. Radon is originated from decay of radium-226 and radium-228 present in rocks. Radon and its short-lived progeny can be retained in the workers pulmonary alveoli, and this way they bring about cancer risk to these mining professionals. The occurrence of high radon concentrations in underground coal and copper mines and the lack of systematic survey motivated CNEN, the regulatory agency, to develop the Radon Project, aiming to aid the formulation of a specific regulation with occupational dose limits consistent with international standards recommended by the International Atomic Energy Agency (IAEA). Dozens of underground mines are currently in operation in the national. It had to be noted that about 50% of these mines are located in Minas Gerais province, and for this reason it was chosen to start the Project. In each underground mine it is installed in selected points passive nuclear track etch radon detectors, type LEXAN and Cr-39, for periods from three to five months. It was also made local measurements with Dose Man Pro detectors from SARAD. The points are chosen according to geological features, radiometric activity and characteristics of prospect development. The determination of radon present in mines has been made in IEN (Nuclear Engineering Institute)/Rio de Janeiro-RJ, LAPOC (Pocos de Caldas Laboratory)/Pocos de Caldas-MG e ESPOA (Porto Alegre Office)/Porto Alegre-RS. Until now it was visited about 35 mines in a universe of about 50 mines, from which 20% showed concentration values higher than international limits (ICRP 65), between 500 and 1500 Bq.m -3 . (author)

  1. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    International Nuclear Information System (INIS)

    Mittal, Sudhir; Asha Rani; Mehra, Rohit

    2015-01-01

    In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The water samples are taken from hand pumps and tube wells having depths ranging from 50 to 600 feet. All the soil gas measurements have been carried out at 100 cm depth. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l -1 with the mean value of 4.42 Bq l -1 . Only in one water sample radon concentration is found to be higher than the safe limit of 11 Bq l -1 recommended US Environmental Protection Agency (USEPA, 1991). The measured value of radon concentration in all ground water samples is within the safe limit from 4 to 40 Bq l -1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008). The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60 μSV y -1 with the mean value of 12.08 μSV y -1 . The total annual effective dose from all locations of our studied area is found to be well within the safe limit 0.1 mSv y -1 recommended by World Health Organization (WHO, 2004) and European Council (ED, 1998). Radon measurement in soil samples varies from 941 to 10050 Bq m -3 with the mean value of 4561 Bq m -3 , The radon concentration observed from the soil samples from our study area lies within the range reported by other investigators. Moreover a positive correlation of radon concentration in water with soil samples has been observed. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard. (author)

  2. A study of radon-222 concentrations in North Carolina groundwater

    International Nuclear Information System (INIS)

    Evans, J.P.

    1992-01-01

    The groundwater of 400 North Carolina homes was sampled to ascertain the distribution and extent of 222 Rn in North Carolina groundwater. Arithmetic mean (AM) and geometric mean (GM) concentrations of 1,816 pCi L -1 and 656 pCi L -1 were found for the state. These results indicate that two-thirds of 114 degree C. homes served by groundwater exceed the EPA proposed 300 pCi L -1 maximum contaminant level (MCL). Only 2% of NC homes exceeded 10,000 pCi L-1. The Eastern region had the lowest radon concentrations by far, with a GM of 2-)0 pCi L -1 . The Central region and Western region had GM's of 794 pCi L -1 and 1,032 pCi L -1 respectively. The groundwater data approached a log normal distribution. No consistent trends were noted in the relationship between indoor radon concentrations and groundwater radon concentrations. A correlation coefficient of 0.00921 revealed a very weak linear relationship

  3. The effect of the nuclear track detectors' position on the radon concentration measurements

    International Nuclear Information System (INIS)

    Yilmaz, A.; Kuerkcueoglu, M. E.; Haner, B.

    2009-01-01

    It is important to determine the radon concentration values of the underground mines according to workers' health. For this purpose, to be able to measure radon concentrations by using passive nuclear etched track detectors, CR-39 detectors were placed into 66 points on the way of aeration galleries of Armutcuk, Amasra, Karadon, Kozlu and Uezuelmez bituminous coal mines which are known as the Carboniferous outcrops of the Western Black Sea Area in Turkey. In every measurement point, a pair of detectors, one of them is being perpendicular and the other one is parallel to air flow, were exposed to radon gases over 40 days for four seasons of the year 2008. The relationship between the readings of vertically and horizontally positioned detectors was investigated by evaluating the effect of the detectors' positions on the detected radon concentrations. It can be concluded that, the vertically positioned detectors, in general, recorded higher radon gases concentration values than that of the horizontally positioned ones.

  4. Soil gas radon concentration across faults near Caracas, Venezuela

    International Nuclear Information System (INIS)

    Sajo-Bohus, L.; Flores, N.; Urbani, F.; Carreno, R.

    2001-01-01

    SSNTD were used across tectonic features of different degree of activity and lithology in four localities north of Caracas, Venezuela. The homemade dosimeters with LR115 film were buried 20-30 cm in the ground. This cheap and low- tech method proved very useful to understand the tectonic features involved, measuring higher Radon concentration above traces of active faults while in old and sealed faults the results only show the effect of the surrounding lithology. Radon concentration range is 4.3 - 27.2 kB/m 3 . (Author)

  5. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  6. Studies on radon concentration in underground water samples in and around Kabini river basin

    International Nuclear Information System (INIS)

    Yashaswini, T.; Ningappa, C.; Niranjan, R.S.; Sannappa, J.

    2017-01-01

    Radon is a radioactive inert gas, a decay product of radium, causes environmental health problems like lung cancer. Radium present in the earth crest continuously releases radon into underground water. From the point view of health, the study of radon concentration level in underground water base line data is important. In the present study, radon concentration in underground water have been measured in 40 underground water samples collected in and around Kabini River of Karnataka State by using Emanometry technique. The radon concentration in the study area varies from 21.2 to 168.2Bq.l -1 with a geometrical mean value of 73.3 Bq.l -1 . The physicochemical parameters of water such as chloride, Fluoride, nitrite, sulphate, TDS are measured in the same samples in order to know about the impact of these parameters on radon concentration and their health risks to the general public. The experimental techniques and results obtained are discussed in the presentation. (author)

  7. Diurnal radon-222 concentrations in the outflow of a complex basin

    International Nuclear Information System (INIS)

    Clements, W.E.; Wilkening, M.

    1981-01-01

    Radon 222 concentrations were monitored continuously in the outflow from the Anderson and Putah Creek air drainage basin as part of the Department of Energy's Atmospheric Studies in Complex Terrain September 1980 field studies. Radon 222, an inert gas having a half-life of 3.8 days, can be considered to be exhaled uniformly at a constant rate from the earth's surface throughout the basin. The contribution to the total radon budget from vented steam from geothermal wells in the Geysers area is neglected. Hence, radon in this application is used as an extended-source atmospheric tracer in contrast with point-source release of tracer materials. One of the purposes of this study is to help classify drainage flow nights in terms of the diurnal patterns of radon concentration. As cool slope winds move along the terrain and into the valley, the air masses involved accumulate radon through the night until morning instabilities mix it to greater depths. Hence, the measured diurnal trend of radon in the outflow of the basin reflects the integrated behavior of nocturnal flows in the basin and subsequent breakup in the morning. The use of this technique to classify drainage flows has been used by Wilkening and Rust

  8. Problems of the inclusion of workplaces with enhanced radon and radon daughter concentrations into occupational radiation protection control

    International Nuclear Information System (INIS)

    Przyborowski, S.

    1993-01-01

    New international recommendations (ICRP-60) on inclusion of workplaces with enhanced radon and radon daughter concentrations into occupational control are expected. Based on present regulations in Germany the problems of their implementation into radiation protection practice will be discussed. For underground workplaces and workplaces in radon spas and waterworks problems may be exist in particular points, whereas inclusion of workplaces in buildings seems to be problematicly in general. (orig./HP) [de

  9. Radon in air concentrations arising from storage of articles containing radium or thorium

    International Nuclear Information System (INIS)

    Slater, M.; Gooding, M.

    2006-01-01

    A major component of public and occupational radiation exposure worldwide arises from the inhalation of radon and thoron gases, produced during the decay of naturally occurring uranium and thorium respectively. Whilst radon and thoron exposures are normally associated with the natural environment, there may also be a risk associated with sources, manufactured articles and waste produced through refining and concentration of naturally occurring radioactive material. Sources and articles manufactured from refined uranium do not normally give rise to the release of radon as the uranium progeny are largely removed during production and, if removed, will take thousands of years to reach full equilibrium with the uranium parent isotopes. Exposure to radon -222 ( 222 Rn) may, however, arise in areas where the uranium-238 ( 238 U) daughter radium-226 ( 226 Ra) is concentrated, for example in the form of sources, luminous articles or low-specific activity (LSA) scale. Exposure to radon- 220 ( 220 Rn), otherwise known as thoron, may occur in areas where thorium isotopes are concentrated, for example as manufactured laboratory thorium compounds. This paper explores the issues affecting radon and thoron release from manufactured articles containing uranium and thorium and their progeny. A methodology is provided for the calculation of 222 Rn and 220 Rn in air concentrations likely to arise as a result of the storage and use of articles containing radium-226 ( 226 Ra) or thorium-232 ( 232 Th). The methodology provided in the document allows derivation of the equilibrium equivalent radon concentration and the radon exposure rate in circumstances where the ventilation rate and volume of the facility can be reliably estimated and the quantities of 226 Ra or 232 Th held are known. A critical variable in the calculation is the release fraction (i.e. the proportion of radon generated that is release to atmosphere), and this paper considers methods for estimating this parameter

  10. The unattached fraction of radon decay products: Potential effects of in-home air cleaners on lung cancer risk

    International Nuclear Information System (INIS)

    Brady, P.A.

    1991-01-01

    Radon decay products are a factor in the development of lung cancer. Because of their efficient deposition within the lung, the fraction of decay products not attached to particulate (i.e., the unattached fraction) is very important in lung dosimetry. This study simulated the use of two in-home air cleaning devices to reduce airborne particulate concentrations, measure the effect on the unattached fraction, and estimate the radon lung cancer risk. Radon was released into a chamber having a volume-to-surface-area ratio similar to a small home. At radon-decay product equilibrium, radon and airborne particle concentrations were measured, and the concentration of the unattached fraction was estimated. The effect of particle concentration on the unattached fraction was then determined. The average unattached fractions corresponding to the particle concentration ranges expected for the air cleaning devices were used to calculate the annual alpha radiation dose and annual radon lung cancer for men, women and children at rest and under light activity. The annual doses and related risks were compared to those used in the models published by the Environmental Protection Agency. For particulate concentrations of a home with no particulate generating activities (e.g., smoking, cooking), the electronic air cleaner is predicted to reduce the unattached fraction from seven percent (the value used by the NCRP and confirmed in this study) to four percent. These conditions represent the maximum reduction in the unattached fraction. The decrease in the unattached fraction is tentatively attributed to an increase in plateout. Based on these results, a reduction of less than ten percent in the calculated annual lung cancer risk is found in all cases

  11. Measurement of radon activity concentration in buildings

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Pineau, C.; Dechaux, E.

    2010-01-01

    Radon exposure, along with medical-related exposure, is the leading source of exposure to ionising radiation for the French population. Measurement campaigns are done in the action plan, drawn up by the French nuclear safety authority (ASN), in cooperation with the French directorate for housing, town planning and countryside (DHUP), the French radiation protection and nuclear safety institute (IRSN), the French health monitoring institute (InVS) and the French scientific and technical centre for construction (CSTB). The review of 2005-2008 measurement campaign shows that of the 7356 buildings screened, 84.8% had activity concentration levels below the 400 Bq/m 3 action level. For the other buildings (15.2%), action will be required to reduce human exposure to radon, possibly including building renovation/redevelopment work. In the 1999-2002 measurement campaign,12% of the 13,000 buildings screened had a radon activity concentration level higher than 400 Bq/m 3 . In addition, the ASN and the French general directorate of labour (DGT) are continuing to work on drawing up regulations for occupational risk management. The second national health and environment plan (PNSE 2) was published on 26 June 2009. It follows on from the actions initiated in PNSE 1, a document provided for under the Public Health Act dated 9 August 2004 and under the French 'Grenelle' environmental agreements. On the basis of guidelines laid out in PNSE 2, a radon action plan for 2009-2012 will be drawn up, enabling some of the actions to be continued, particularly in the fields of new building projects and dwellings. (author)

  12. Attempt to determine radon entry rate and air exchange rate variable in time from the time course of indoor radon concentration

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J [State Office for Nuclear Protection, Prague (Czech Republic)

    1996-12-31

    For radon diagnosis in houses the `ventilation experiment` was used as a standard method. After removal of indoor radon by draught the build-up of radon concentration a(t) [Bq/m{sup 3}] was measured continuously and from the time course the constant radon entry rate A [Bq/h] and the exchange rate k [h{sup -1}] was calculated by regression analysis using model relation a(t) A(1-e{sup -kt})/kV with V [m{sup 3}] for volume of the room. The conditions have to be stable for several hours so that the assumption of constant A and k was justified. During the day both quantities were independently (?) changing, therefore a method to determine variable entry rate A(t) and exchange rate k(t) is needed for a better understanding of the variability of the indoor radon concentration. Two approaches are given for the determination of variable in time radon entry rates and air exchange rates from continuously measured indoor radon concentration - numerical solution of the equivalent difference equations in deterministic or statistic form. The approaches are not always successful. Failures giving a right ration for the searched rates but not of the rates them self could not be explained.

  13. Radon exhalation rates from soil and sand samples collected from the vicinity of Yamuna river

    International Nuclear Information System (INIS)

    Garg, A.K.; Sushil Kumar; Chauhan, Pooja; Chauhan, R.P.

    2011-01-01

    Soil, sand and stones are the most popular building materials for Indian dwellings. Radon is released into ambient air from these materials due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in sand and soils is related to radioactivity in the rocks from which they are formed. These materials contain varying amount of uranium. In the present investigation, the radon emanated from soil and sand samples from different locations in the vicinity of Yamuna river has been estimated. The samples have been collected from different locations near the Yamuna river. The samples collecting sites are from Yamunanagar in Haryana to Delhi. The radon concentration in different samples has been calculated, based upon the data, the mass and the surface exhalation rates of radon emanated from them have also been calculated

  14. RADON CONCENTRATION TIME SERIES MODELING AND APPLICATION DISCUSSION.

    Science.gov (United States)

    Stránský, V; Thinová, L

    2017-11-01

    In the year 2010 a continual radon measurement was established at Mladeč Caves in the Czech Republic using a continual radon monitor RADIM3A. In order to model radon time series in the years 2010-15, the Box-Jenkins Methodology, often used in econometrics, was applied. Because of the behavior of radon concentrations (RCs), a seasonal integrated, autoregressive moving averages model with exogenous variables (SARIMAX) has been chosen to model the measured time series. This model uses the time series seasonality, previously acquired values and delayed atmospheric parameters, to forecast RC. The developed model for RC time series is called regARIMA(5,1,3). Model residuals could be retrospectively compared with seismic evidence of local or global earthquakes, which occurred during the RCs measurement. This technique enables us to asses if continuously measured RC could serve an earthquake precursor. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Radon concentration, absorbed dose rate in air and concentration of natural radionuclides in soil in the Osaka district of Japan

    International Nuclear Information System (INIS)

    Megumi, K.; Matsunami, T.; Ishiyama, T.; Abe, M.; Kimura, S.; Yamazaki, K.; Tsujimoto, T.

    1992-01-01

    Radon concentrations in outdoor air at 18 sites in the Osaka district, in the central part of Japan's main island, were measured with electrostatic integrating radon monitors which were developed by Y Ikebe et al of the Osaka survey centre as part of a nationwide survey of radon indoors and outdoors in Japan conducted by the National Institute of Radiological Science. The mean radon concentration in outdoor air during 2-month periods was measured over a period of a year and a half. In addition, the absorbed dose rate in air and the concentration of natural radionuclides in soil were measured at 40 sites in Osaka Prefecture which is located in the central part of the Osaka district using thermoluminescence dosemeters and with gamma ray spectrometry, respectively. Radon concentration in outdoor air showed a seasonal pattern, reaching its maximum during the winter and its minimum during the summer, but this variation was not significant at the coastal sites. It was concluded that this variation is correlated with a seasonal wind which blows from the continental interior to the ocean in winter and in the opposite direction in summer, as well as with geographical factors. Radon concentration in outdoor air in the Osaka district ranged from 0.6 to 17.9 Bq.m -3 and mean annual radon concentration in outdoor air at the 18 sites ranged from 2.7 to 6.9 Bq.m -3 . It was discovered that radon concentration in outdoor air decreased with wind speed in both winter and summer. The absorbed dose rate in air ranged from 66 to 114 nGy.h -1 , and the concentration of 226 Ra in soil ranged from 20 to 60 Bq.kg -1 respectively. (author)

  16. Measurement of radon, radon daughters and thoron concentrations by multi-detector devices. No. E/12

    International Nuclear Information System (INIS)

    Somogyi, G.; Varga, Zs.

    1983-01-01

    There is a growing interest in collection of data concerning human exposures to naturally occurring alpha-emitting radionuclides (e.g. in mines, dwellings, building materials, industrial wastes, coal fuel cycle, water supply, soil, plants, etc.). Most of such studies are incomplete for the following reasons: in radon measurements the contribution of thoron is generally neglected, the determination of equilibrium factor is complicated or not possible at all, short- and long-term concentration fluctuations cause difficulties in obtaining representative mean values, the plate-out effect is generally not taken into account. A variety of simple methods were studied that could be used to overcome some of these difficulties by using cups equipped with two or more alpha-sensitive nuclear track detectors. A theoretical foundation of the quantitative measurements with such devices is presented. Experimental data are reported on radon, radon daughters and thoron concentrations measured by multi-detector devices in cave soil gas and in air of Hungarian dwellings. (author)

  17. The application of air pressure difference in reducing indoor radon concentration

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Tso, M.Y.W.

    2000-01-01

    In densely populated tropical cities like Hong Kong, people usually live and work inside high-rise buildings. And because of the hot and humid climate, air conditioning systems are used throughout the year, particularly in commercial buildings. Previous territory-wide surveys have shown that over 10% of commercial buildings in Hong Kong have indoor radon concentrations above 200 Bq m -3 . Since the major source of indoor radon in high-rise buildings is the building materials, increasing ventilation and applying radon barriers on wall surfaces seem to be the only ways to reduce the indoor radon concentration. But it was noted that the ventilation rate the many commercial buildings are not efficient enough to remove the radon because of various reasons such as energy saving, lack of maintenance, etc. In this study, radon mitigation was achieved by reducing the rate of radon exhaled from the building materials. A special laboratory, which has the capability of simulating any meteorological conditions that could be faced by high-rise buildings in Hong Kong, was built. The reduction of radon exhalation rate by applying pressure difference and temperature difference across walls was studied in the laboratory. This paper summarizes the results and tactics for applying pressure difference in existing commercial buildings. A new technique of reducing radon exhalation rate in new buildings by depressurizing the interior of walls was also developed. Tunnels can be embedded in the concrete walls of new buildings during construction. By using simple vacuum pumps, radon exhalation rate from the walls can be reduced significantly by depressurizing the tunnels. The feasibility and applicability of the technique is presented in this paper. (author)

  18. Comparative study of radon concentration in selected modern and traditional building at Kenyatta University

    International Nuclear Information System (INIS)

    Chege, W.M.; Rathore, I.V.S.; Chhabra, S.C.; Mustapha, A.O.

    2010-01-01

    Radon is leading source of radiation exposure to the public and increases risk of cancer (UNSCEAR, 2000). There is general lack of data on indoor radon in Kenya especially on building design-traditional versus modern. In rural Kenya traditional mud huts coexist with modern stone building. Indoor radon found to vary widely in Kenya: Mustapha et al (2002): 5-1200 Bqm3, Maina et al (2004): 5-704 Bqm3. None of previous works indicates radon variation with building design. The aim of the current study is to compare radon concentrations in coexisting stone buildings and mud huts. Such data would be useful in formulation of policies regarding housing, as part of radon data base in Kenya Experimental Techniques Characteristic of selected buildings: Traditional Huts: Single roomed, Wall made of wood and plastered using mud, bare floor and no ceiling, grass-thatched or mud plastered, doors and windows remained open during the sampling period. Modern Buildings: (Classes used to represent modern building). Those made of natural stone, wooden floor, ceiling, doors and windows remained shut during the sampling period. Measurement of Radon Concentration Radon sampling was done using Charcoal canisters (EPA type). They were activated, and then exposed simultaneously at sampling sites for 48 hours. Analysis and data acquisition was done using NaI(Tl) gamma-ray spectrometer. Radon concentration was calculated based on gamma rays emitted by 214Pb (295 and 352 keV) and 214Bi (609 keV). 13 Results and Discussion Radon levels were higher in classrooms and significantly high in huts. Mean (Bqm-3 ) Minimum (Bqm-3 ) Maximum (Bqm-3 ). Traditional huts had 170.3 15.6 30.2 315.4 while modern buildings had 193 ±19.3 115.76 257.2. There were higher levels in classroom despite lower levels of 226Ra (50.18 Bqkg-1) in natural stone. Possible source of high concentrations: - radon seeping in through floor boards building up over time as building more closed up - Radon concentration was more varied

  19. A survey on radon reduction efficiency of zeolite and bentonite in a chamber with artificially elevated radon concentration

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.

    2007-01-01

    Complete text of publication follows. Objective: Zeolite which is made of a special crystalline structure is a naturally occurring mineral group and can be used in radioactive waste management for site remediation /decontamination. There are a wide variety of naturally occurring and synthetic zeolites, each with a unique structure. The cations in zeolite are highly mobile and can be exchanged for other cationic species. On the other hand, bentonite forms from weathering of volcanic ash. This material may be used as an engineering barrier to enclose nuclear waste. In this study, radon reducing properties of zeolite and bentonite have been investigated. Methods: Using radioactive lantern mantle, a radon prone area with radon levels reaching the EPA's action level (200 Bq/m 3 ) was designed. Two sets of identical chambers (cylindrical chambers, diameter 10 cm, height 16 cm) were used in this study. No zeolite/bentonite was used in the 1 st set of the chambers. A thin layer of either zeolite or bentonite powder was applied to the base of the first set of chambers. An unburned radioactive lantern mantle (activity 800 Bq) was placed in all chambers (both sets) to artificially increase the radon level inside the chamber and simulate the condition of a radon prone area. Radon level monitoring was performed by using a PRASSI portable radon gas survey meter. Results: After placing the cap on its place, the radon levels inside the 1 st set of the chambers were 871.9, 770.3, 769.2 and 635.7 Bq/m 3 after 15, 30, 45 and 60 minutes respectively. Zeolite significantly decreased the radon concentration inside the chambers and radon levels were 367.9, 435.4, 399.0 and 435.4 Bq/m 3 after 15, 30, 45 and 60 minutes. The observed reduction in the radon level was statistically significant. As the radon concentrations in identical chambers with Bentonite were 550.7, 526.5, 536.2 and 479.8 Bq/m 3 after 15, 30, 45 and 60 minutes respectively, it is evident that zeolite is more efficient in

  20. A reconnaissance study of radon concentrations in Hamadan city, Iran

    OpenAIRE

    Gillmore, G.; Jabarivasal, N.

    2010-01-01

    This paper presents results of a reconnaissance study that used CR-39 alpha track-etch detectors to measure radon concentrations in dwellings in Hamadan, western Iran, significantly, built on permeable alluvial fan deposits. The indoor radon levels recorded varied from 4 (i.e. below the lower limit of detection for the method) to 364 Bq/m3 with a mean value of 108 Bq/m3 which is 2.5 times the average global population-weighted indoor radon concent...

  1. Parametric modelling of temporal variations in radon concentrations in homes

    International Nuclear Information System (INIS)

    Revzan, K.L.; Turk, B.H.; Harrison, J.; Nero, A.V.; Sextro, R.G.

    1988-01-01

    The 222 Rn concentrations in the living area, the basement, and the undelying soil of a New Jersey home have been measured at half-hour intervals over the course of a year, as have indoor and outdoor temperatures, wind speed and direction, and indoor-outdoor and basement-subslab pressures; in addition, periods of furnace opration have been logged. We generalize and extend an existing radon entry model in order to demonstrate the dependence of the radon concentration on the environmental variales and the extent of furnace use. The model contains parameters which are dependent on geological and structural factors which have not been measured or otherwise determined; statistical methods are used to find the best values of the parameters. The non-linear regression of the model predictions (over time) on the measured living area radon concentrations yields an R/aup 2/ of 0.88. 9 refs., 2 figs

  2. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offermann, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Furthermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. 7 references, 2 figures

  3. Evaluation of indoor aerosol control devices and their effects on radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.; Offerman, F.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.; Yater, J.

    1984-01-01

    Eleven portable air cleaing devices have been evaluated for control of indoor concentrations of respirable particles, and their concomitant effects on radon progeny concentrations have been investigated. Of the devices we examined the electrostatic precipitators and extended surface filters had significant particle removal rates, while the particle removal rates for several small panel-filters, an ion-generator, and a pair of mixing fans were found to be negligible. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in reducing radon progeny concentrations. Futhermore, at the low particle concentrations, plateout of the unattached radon progeny was found to be a significant removal mechanism. The overall removal rates due to deposition of attached and unattached progeny have been estimated from these data, and the equilibrium factors for total and unattached progeny concentrations have been calculated as a function of particle concentration. (Author)

  4. Radon concentration measurements in therapeutic spring water

    International Nuclear Information System (INIS)

    Deak, N.; Horvath, A.; Sajo B, L.; Marx, G.

    1996-01-01

    It is believed that people undergoing a curative cycle in a given spa, may receive a dose in the range of 400 mSv/year which is many times the average annual dose so that their risk of lung cancer may increase by 3% or more. To determine the risk due to the natural radioactivity, of the most frequented spas in Budapest (H), we selected four and some others located on the country side being of particular interest. Results of the radon concentration in spring water are presented, with the evidence that some spas have a high radon concentration. We conclude that patients receiving treatment may be exposed to an additional dose in the range of 29-76 mSv/year that at the bronchia could be between 445-1182 mSv/year. (authors). 6 refs., 2 figs., 2 tabs

  5. [Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations].

    Science.gov (United States)

    Walczak, Katarzyna; Zmyślony, Marek

    2013-01-01

    Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers), Iran (5), China (4) and India (5). Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings). In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program.

  6. An intercomparison between gross α counting and gross β counting for grab-sampling determination of airborne radon progeny and thoron progeny

    International Nuclear Information System (INIS)

    Papp, Z.

    2006-01-01

    The instantaneous values of the airborne activity concentrations of radon progeny and thoron progeny have been determined 34 times in a closed and windowless room in a cellar using two independent grab-sampling methods in order to compare the performance of the methods. The activity concentration of radon ( 222 Rn) was also measured and it varied between 200 and 650 Bq m -3 . Two samples of radon and thoron progeny were collected simultaneously from roughly the same air volume by filtering. For the first method, the isotopes were collected on membrane filter and gross α counting was applied over several successive time intervals. This method was a slightly improved version of the methods that are applied generally for this reason for decades. For the second method, the isotopes were collected on glass-fibre filter and gross β counts were registered over several time intervals. This other method was developed a few years ago and the above series of measurements was the first opportunity to make an intercomparison between it and another similar method based on α counting. Individual radon progeny and thoron progeny activity concentrations (for the isotopes 218 Po, 214 Pb, 214 Bi and 212 Pb) were evaluated by both methods. The detailed investigation of the results showed that the systematic deviation of the methods is small but significant and isotope-dependent. The weighted averages of the β/α activity concentration ratios for 218 Po, 214 Pb, 214 Bi, EEDC 222 (Equilibrium-Equivalent Decay-product Concentration of radon progeny) and 212 Pb were 0.99±0.03, 0.90±0.02, 1.03±0.02, 0.96±0.02 and 0.80±0.03, respectively. The source of the systematic deviation is probably the inaccurate knowledge of the counting efficiencies mainly in the case of the α-counting method. A significant random-type difference between the results obtained with the two methods has also been revealed. For example, the β/α ratio for EEDC 222 varied between 0.81±0.01 and 1.22±0

  7. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  8. Measurement of dose-determining physical parameters (F-factor, fp factor,...) for comparative analysis of outdoor/indoor radon exposure

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    The purpose of the project was to measure the airborne natural radon activity concentrations outdoor and the dose-determining parameters [non-deposited fraction (f p ), radon daughter products (F, PAEC), as well as the radioactive aerosol size distribution]. The impacts of meteorological parameters (pressure, rainfalls, wind velocities and temperature) on the those parameters and the exhalation of radon from the soil were to be determined. The acquired information was to be applied for an evaluation of the radiological outdoor situation and subsequent comparative analysis with the indoor radon exposure. (orig./CB) [de

  9. Radon concentration in spring and groundwater of Shillong agglomeration

    International Nuclear Information System (INIS)

    Walia, D.; Wahlang, P.; Lyngdoh, A.C.; Saxena, A.; Sharma, Y.; Maibam, D.

    2010-01-01

    Water samples in the month of February 2010 to April 2010 are collected from 06 springs (sample code S1-S6) and 18 wells (sample code W1-W18) of the Shillong agglomeration in radon-tight 1L bottles, considering the geological structures, nearness to the steep slopes and accessibility of the water sources. The measurement of radon in water samples is carried out using ionization chamber Alphaguard along with an accessory (fabricated in the laboratory). Initially, background radon of the empty set-up is measured for 30 minutes before every water-sample measurement. The water samples are placed in a closed gas cycle in degassing vessel and then radon is expelled using the pump and magnetic stirrer. The security vessel is connected with the degassing vessel to minimize the inflow of water vapour to the Alphaguard. The measuring cycle is repeated 3 times in order to obtain a better precision. The arithmetic mean of the radon concentrations are used for calculating the annual effective dose for ingestion of water from each bore well and spring. The pH, electrical conductivity and temperature are measured so as to correlate the meteorological parameters with the radon emanation

  10. Maximum permissible concentration of radon {sup 222}Rn in air; La concentration maximale admissible du radon 222 dans l'air

    Energy Technology Data Exchange (ETDEWEB)

    Hamard, J; Beau, P G; Ergas, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires, departement de la protection sanitaire, service d' hygiene atomique

    1968-09-01

    In order to verify the validity of the values proposed for the maximum permissible concentration of {sup 222}Rn in air, one can either approach the problem: - by epidemiological studies tending to determine the relation dose-effect both quantitatively and qualitatively; - or by choosing a lung model and clearance constants allowing a more accurate determination of the delivered dose and the localisation of the more severely irradiated portions of the bronchial tree. The radon MPC have been calculated using the model and the respiration constants set up by the I.C.R.P. Task Group on Lung dynamics. Two cases have been considered, i.e. when the radon daughter products behave as soluble materials and as insoluble ones. The values which have been found have been compared with those given up to now by several national and international bodies. (authors) [French] Deux voies d'approche peuvent etre empruntees pour verifier la validite des valeurs proposees pour la concentration maximale admissible du radon 222 dans l'air: - etudes epidemiologiques tendant a preciser qualitativement et quantitativement la relation dose-effet; - choix d'un modele pulmonaire et de constantes d'epuration permettant une determination plus precise de la dose delivree et la localisation des segments de l'arbre pulmonaire les plus irradies. Les auteurs ont utilise pour le calcul de la CMA du radon le modele et les constantes respiratoires proposees par le Task Group on Lungs dynamics de la C.I.P.R. On a pris en consideration le cas ou les descendants du radon se comportent comme des substances solubles et celui ou ils se comportent comme des substances insolubles. Les valeurs trouvees sont comparees a celles proposees jusqu'alors par divers organismes nationaux et internationaux. (auteurs)

  11. Measurements and statistical analyses of indoor radon concentrations in Tokyo and surrounding areas

    International Nuclear Information System (INIS)

    Sugiura, Shiroharu; Suzuki, Takashi; Inokoshi, Yukio

    1995-01-01

    Since the UNSCEAR report published in 1982, radiation exposure to the respiratory tract due to radon and its progeny has been regarded as the single largest contributor to the natural radiation exposure of the general public. In Japan, the measurement of radon gas concentrations in many types of buildings have been surveyed by national and private institutes. We also carried out the measurement of radon gas concentrations in different types of residential buildings in Tokyo and its adjoining prefectures from October 1988 to September 1991, to evaluate the potential radiation risk of the people living there. One or two simplified passive radon monitors were set up in each of the 34 residential buildings located in the above-mentioned area for an exposure period of 3 months each. Comparing the average concentrations in the buildings of different materials and structures, those in the concrete steel buildings were always higher than those in the wooden and the prefabricated mortared buildings. The radon concentrations were proved to become higher in autumn and winter, and lower in spring and summer. Radon concentrations in an underground room of a concrete steel building showed the highest value throughout our investigation, and statistically significant seasonal variation was detected by the X-11 method developed by the U.S. Bureau of Census. The values measured in a room at the first floor of the same concrete steel building also showed seasonal variation, but the phase of variation was different. Another multivariate analysis suggested that the building material and structure are the most important factors concerning the levels of radon concentration among other factors such as the age of the building and the use of ventilators. (author)

  12. Measurement of Radon, Thoron, Isotopic Uranium and Thorium to Determine Occupational and Environmental Exposure and Risk at Fernald Feed Material Production Center

    International Nuclear Information System (INIS)

    Harley, Naomi H.

    2004-01-01

    To develop a new and novel area and personal radon/thoron detector for both radon isotopes to better measure the exposure to low airborne concentrations of these gases at Fernald. These measurements are to be used to determine atmospheric dispersion and exposure to radon and thoron prior to and during retrieval and removal of the 4000 Ci of radium in the two silos at Fernald

  13. Measurement of radon-222 concentration in environment sampled within short time using charcoal detector

    International Nuclear Information System (INIS)

    Yamasaki, Tadashi; Sekiyama, Shigenobu; Tokin, Mina; Nakayasu, Yumiko; Watanabe, Tamaki.

    1994-01-01

    The concentration of 222 Rn in air sampled within a very short period of time was measured using activated charcoal as the adsorber. The detector is the plastic canister containing mixture of the activated charcoal and the silica gel. The radon gas was adsorbed in the charcoal in the radon chamber at the temperature of 25degC. A little amount of liquid scintillation cocktail was added into the vial of liquid scintillation counter with the canister. The radon in the charcoal was extracted in the liquid scintillation cocktail. Alpha particles emitted from radon and its daughter nuclei in the cocktail were detected using the liquid scintillation counter. Present method has advantages of not only short sampling time of air but also adsorption of radon in charcoal under a constant temperature. The concentration of radon in air down to 2 Bq/m 3 could be detected. A kinetic model for adsorption of radon in the charcoal is also presented. The ratio of radon concentration in the charcoal to that in air under the equilibrium state of adsorption was estimated to be from 6.1 to 6.8 m 3 /kg at the temperature of 25degC. (author)

  14. Indoor radon concentration and its possible dependence on ventilation rate and flooring type

    International Nuclear Information System (INIS)

    Ashok, G. V.; Nagaiah, N.; Shiva Prasad, N. G.

    2012-01-01

    The results of radon concentration measurements carried out in dwellings with natural ventilation for 1 y in Bangalore are reported. Measurements, covering three sessions of the day (morning, afternoon, night) were performed two times in a month for 1 y at a fixed place of each dwelling at a height of 1 m above the ground surface in selected dwellings. The low-level radon detection system (LLRDS), an active method, was used for the estimation of radon concentration. The measurements were aimed to understand the diurnal variation and the effect of ventilation rate and flooring type on indoor radon concentration. The geometric mean (±geometric standard deviation) of indoor radon concentration from about 500 measurements carried out in 20 dwellings is found to be 25.4 ±1.54 Bq m -3 . The morning, afternoon and night averages were found to be 42.6 ±2.05, 15.3 ±2.18 and 28.5 ±2.2 Bq m -3 , respectively. The approximate natural ventilation rates of the dwellings were calculated using the PHPAIDA-the on-line natural ventilation, mixed mode and air infiltration rate calculation algorithm and their effects on indoor radon concentrations were studied. The inhalation dose and the lung cancer risk due to indoor radon exposure were found to be 0.66 mSv y -1 and 11.9 per 10 6 persons, respectively. The gamma exposure rate was also measured in all the dwellings and its correlation with the inhalation dose rate was studied. (authors)

  15. Methodology developed to make the Quebec indoor radon potential map

    Energy Technology Data Exchange (ETDEWEB)

    Drolet, Jean-Philippe, E-mail: jean-philippe.drolet@ete.inrs.ca [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Martel, Richard [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Poulin, Patrick [Institut national de santé publique du Québec (INSPQ), 945 avenue Wolfe, G1V 5B3 Quebec (Canada); Dessau, Jean-Claude [Agence de la santé et des services sociaux des Laurentides, 1000 rue Labelle, J7Z 5 N6 Saint-Jérome (Canada)

    2014-03-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m{sup 3} in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for

  16. Radon concentrations in houses around the Plomin coal-fired power plant

    International Nuclear Information System (INIS)

    Lokobauer, N.; Franic, Z.; Sencar, J.; Bauman, A.; Sokolovic, E.

    1997-01-01

    Investigation of radon activity concentration in houses around the Plomin coal-fired power plant (Istrian Peninsula) started in the winter of 1990 upon the assumption that certain old houses in this region were built using mortar and plaster prepared from slag and ash. This paper presents the results of a preliminary investigation carried out in the winter of 1990 and spring of 1991, when the difference between radon levels in old and newly built houses was first noted, and the subsequent data obtained by radon measurements in 40 selected houses in the period from 1992 to 1994. The average annual radon activity concentrations in the old houses ranged from 55 Bqm -3 to 426 Bqm -3 (mean value 146 ± 91 Bqm -3 ) and in more recently built houses from 16 Bqm -3 to 67 Bqm -3 (mean value 36 ± 13 Bqm -3 ). The average annual effective doses from inhalation of radon progeny for the inhabitants living in the old and newly built houses were estimated to be 2.7 mSv and 0.7 mSv, respectively. (Author)

  17. Determination of indoor radon concentrations at the elementary schools of Fatih district in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Kurt, A., E-mail: aziz.kurt@istanbul.edu.tr; Yalcin, L. Sahin, E-mail: latife.sahin@gmail.com; Oktem, Y., E-mail: sgyks@istanbul.edu.tr; Akkus, B., E-mail: akkus@istanbul.edu.tr; Bozkurt, E., E-mail: enginbozkurt88@gmail.com; Hafizoglu, N., E-mail: nurgulhfz87@gmail.com; Ozturk, F. C., E-mail: fcaglaozturk@gmail.com; Aytan, O., E-mail: ozgur@aytan.net; Ertoprak, A., E-mail: aysegulertoprak@gmail.com [Istanbul University, Science Faculty, Physics Department, 34134, Istanbul (Turkey)

    2016-03-25

    Radon is an odorless, tasteless, colorless noble radioactive gas which is produced within the radioactive decay chain of Uranium. The Radon forms in rocks, diffuses into soil and then escapes into atmosphere. When human exposure to high concentration of radon gas from inside, risk of developing lung cancer is increased. There are many methods to determine {sup 222}Rn concentration in the air. In this study, radon concentration of confined air spaces were measured by using LR-115 solid state nuclear track detectors. 509 LR-115 nuclear trace detectors were placed to 25 schools in Fatih District and they effective dose values were calculated. The results of measurements showed that the radon concentration varies between 40-395 Bq/m{sup 3}. This results compared with Turkey’s limits (400 Bq/m{sup 3}) are low, conversely higher compared with WHO’s limits (100 Bq/m{sup 3}).

  18. A critical analysis of climatic influences on indoor radon concentrations: Implications for seasonal correction.

    Science.gov (United States)

    Groves-Kirkby, Christopher J; Crockett, Robin G M; Denman, Antony R; Phillips, Paul S

    2015-10-01

    Although statistically-derived national Seasonal Correction Factors (SCFs) are conventionally used to convert sub-year radon concentration measurements to an annual mean, it has recently been suggested that external temperature could be used to derive local SCFs for short-term domestic measurements. To validate this approach, hitherto unanalysed radon and temperature data from an environmentally-stable location were analysed. Radon concentration and internal temperature were measured over periods totalling 1025 days during an overall period of 1762 days, the greatest continuous sampling period being 334 days, with corresponding meteorological data collected at a weather station 10 km distant. Mean daily, monthly and annual radon concentrations and internal temperatures were calculated. SCFs derived using monthly mean radon concentration, external temperature and internal-external temperature-difference were cross-correlated with each other and with published UK domestic SCF sets. Relatively good correlation exists between SCFs derived from radon concentration and internal-external temperature difference but correlation with external temperature, was markedly poorer. SCFs derived from external temperature correlate very well with published SCF tabulations, confirming that the complexity of deriving SCFs from temperature data may be outweighed by the convenience of using either of the existing domestic SCF tabulations. Mean monthly radon data fitted to a 12-month sinusoid showed reasonable correlation with many of the annual climatic parameter profiles, exceptions being atmospheric pressure, rainfall and internal temperature. Introducing an additional 6-month sinusoid enhanced correlation with these three parameters, the other correlations remaining essentially unchanged. Radon latency of the order of months in moisture-related parameters suggests that the principal driver for radon is total atmospheric moisture content rather than relative humidity. Copyright

  19. Diurnal measurement of equilibrium equivalent radon/thoron concentration using time integrated flow mode grab sampler

    International Nuclear Information System (INIS)

    Pant, P.; Kandari, T.; Ramola, R.C.; Semwal, C.P.; Prasad, M.

    2018-01-01

    The basic processes which influenced the concentration of radon and thoron decay products are- attachment, recoil and deposition and by the room specific parameters of radon exhalation and ventilation. The freshly formed decay products have a high diffusivities (especially in air) and ability to stick to surfaces. According to UNSCEAR 1977, radon daughters may be combined as the so called equilibrium equivalent concentration which is related to the potential alpha energy distribution concentration. In the present study an effort has been made to see the diurnal variation of radon and thoron progeny concentration using time integrated flow mode sampler

  20. Measurement of concentration and size distribution of radon decay products in homes using air cleaners

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; McCallum, B.

    1992-01-01

    By removing particles, air cleaners can also eliminate radon decay products. However, by removing the particles, the open-quotes unattachedclose quotes fraction of the radon progeny is increased leading to a higher dose per unit exposure. Thus, both the concentration and size distributions of the radon decay products are needed to evaluate air cleaners. Three types of room air cleaners, NO-RAD Radon Removal System, Electronic Air Cleaner and PUREFLOW Air Treatment System were tested in a single family home in Arnprior, Ontario (Canada). Semi-continuous measurements of radon gas concentration and radon decay product activity weighted size distribution were performed in the kitchen/dining room under real living conditions. The effects of air cleaners on both the concentration and size distribution of the radon decay products were measured, and their impact on the dose of radiation given to the lung tissue were examined

  1. Measurements of environmental radon - 222 concentrations in indoors and outdoors in Egypt

    International Nuclear Information System (INIS)

    Kenawy, M.A.; Morsey, A.A.; Kotb, M.A.; Osman, A.; El-Haag, A.

    1990-01-01

    The major contribution to population exposure from natural radiation arises from the inhalation of the decay products of radon. Substantial surveys are being conducted by several investigators to estimate the indoor and outdoor exposure nationally and to discover regional variations. In this work, radon concentration in the indoors and outdoor air was determined using the can technique and employing CR-39 solid state nuclear track detector for lengthy exposures. The range of radon - 222 activity in this survey was 54 -299 PCi.m -3 in Cairo, 22 - 171 PCi.m -3 in Alexandria and 89 - 370 PCi.m -3 in Asiut. Measurements carried out in Aswan and Sinai ranged between 98 - 411 PCi.m -3 . Values of indoors and outdoors radon concentrations were found to vary with time of day, geographic location, season and height above ground. Further work is going on to study the different parameters affecting the levels of the environmental radon. The national survey and associated studies is expected to yield data that may correlate radon activity with some respiratory diseases, particularly lung cancer. (author). 7 refs, 5 figs

  2. External gamma exposure to radon progeny in indoor air

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1985-01-01

    The external γ-exposure from radon progeny uniformly distributed in indoor air was estimated by a computer program that was developed. This program can calculate the fluence rate, exposure rate and average energy for any given point in a room of any given size. As numerical example, the exposure rate normalized to unit airborne activity is presented, together with the fluence-weighted and exposure-weighted average photon energies, for a room of representative geometry containing radon progeny in equilibrium. To cover other conditions encountered in practice, quantitative evaluations are additionally presented of the effect on the exposure brought by changes in certain parameters, such as equilibrium factor, wall thickness, room size and receptor position. The study has quantitatively substantiated the prevailing postulate that the effective dose equivalent due to external exposure resulting from normal indoor concentrations of airborne radon progeny in the room of representative geometry should only amount to 0.04 % of that from the internal exposure from the same sources, and that it should be of similarly negligible order compared with internal exposure also in the case of other room geometries. (author)

  3. Radon concentrations in the water of Misasa area (Tottori Pref.)

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko; Inagaki, Masayo [Kinki Univ., Higashi-Osaka, Osaka (Japan); Mifune, Masaaki

    1997-02-01

    UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) Report (1988, 1993) indicated that the internal exposure dose of absorption of radon (Rn-222) and the short-lived decay product nucleus occupied about half of 2.4 m Sv of the global average of annual dose of natural radiation source. It is said to be the largest factor of radiation dose of natural radiation. Sample collection and the method, the elution properties by the concentration of Rn-222 in water and the comparison of characteristics among the different methods are explained. The detection limit of concentration of radon in water by OPTI-FLUOR direct method using the liquid scintillator spectrometer was 1.5 Bq/l for 20 mins counting. The maximum radon concentrations determined by this method showed 1700 Bq/l of the spring water in Misasa area, 400 Bq/l of the small water supply system and well and 18 Bq/l of Mitoku river. (S.Y.)

  4. Effects of bedrock type on the indoor radon concentrations at the office buildings in Gyeongju, Korea

    Directory of Open Access Journals (Sweden)

    Park Hee Chan

    2011-01-01

    Full Text Available This study measured the indoor radon concentrations at 23 administrative office buildings in Gyeongju, Korea, which consists of 23 administrative districts. Using the Korean geological information system, the type of bedrock under the administrative office buildings was identified and classified in 3 major types: granite, sedimentary rock, and sedimentary rock-based fault. The changes in the indoor concentrations at the 23 administrative office buildings were analyzed according to the type of bedrock. As a result, the radon concentration in the areas with the granite bedrock was generally higher than that in the region of two other types of bedrock. In addition, the radon concentration was evaluated according to surface area and construction timing of the building. The indoor radon concentration generally increased with decreasing surface area of the building, particularly in granite distributed areas. For a building aged more than 15 years, the radon concentration in the building in the granite area was much higher. For the building aged 1 or 2 years, the radon concentration was high regardless of the type of the bedrock due to radon emanation from the building material, such as concrete.

  5. Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations

    Directory of Open Access Journals (Sweden)

    Katarzyna Walczak

    2013-04-01

    Full Text Available Background: Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Material and Methods: Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers, Iran (5, China (4 and India (5. Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. Results: We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings. In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. Conclusions: The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program. Med Pr 2013;64(2:193–198

  6. Radon Concentration in Groundwater in the Central Region of Gyeongju, Korea - 13130

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, A. Rim; Park, Chan Hee; Moon, Joo Hyun [Dongguk University, Seokjangdong, Gyeongju, Gyeongbuk, 780-714 (Korea, Republic of)

    2013-07-01

    Radon is a naturally occurring radioactive gas that is a well known cause of lung cancer through inhalation. Nevertheless, stomach cancer can also occur if radon-containing water is ingested. This study measured the radon concentration in groundwater for drinking or other domestic uses in the central region of Gyeongju, Korea. The groundwater samples were taken from 11 points chosen from the 11 administrative districts in the central region of Gyeongju by selecting a point per district considering the demographic distribution including the number of tourists who visit the ancient ruins and archaeological sites. The mean radon concentrations in the groundwater samples ranged from 14.38 to 9050.73 Bq.m{sup -3}, which were below the recommendations by the U.S. EPA and WHO. (authors)

  7. Factors affecting yearly variations of indoor radon concentrations

    International Nuclear Information System (INIS)

    Steck, D.J.; Baynes, S.A.

    1996-01-01

    Since indoor radon exposures take place over many years while radon measurement periods are shorter, we are studying the yearly variation of indoor radon concentrations in approximately 100 houses located throughout Minnesota. Most houses were initially measured for one or more years in the late 1980's and for 5 consecutive years starting in 1990. Two houses have been monitored for 12 y. Each year, two alpha track detectors were placed on the two lowest livable levels. The year-to-year variations averaged about 35% (corrected for instrumental uncertainties) in both basements and first floors. The minimum observed variation was 5% and the maximum was 130%. Some homes have shown substantial variation associated with Structural modifications. While most homes show no obvious systematic trends, a few houses have shown temporal trends that may be associated with aging or climate. We are studying possible correlation between year-to-year radon variation, climatic variables (yearly-average and seasonal such as heating/cooling degree days, precipitation, soil moisture), and structural changes

  8. Hierarchical modeling of indoor radon concentration: how much do geology and building factors matter?

    International Nuclear Information System (INIS)

    Borgoni, Riccardo; De Francesco, Davide; De Bartolo, Daniela; Tzavidis, Nikos

    2014-01-01

    Radon is a natural gas known to be the main contributor to natural background radiation exposure and only second to smoking as major leading cause of lung cancer. The main concern is in indoor environments where the gas tends to accumulate and can reach high concentrations. The primary contributor of this gas into the building is from the soil although architectonic characteristics, such as building materials, can largely affect concentration values. Understanding the factors affecting the concentration in dwellings and workplaces is important both in prevention, when the construction of a new building is being planned, and in mitigation when the amount of Radon detected inside a building is too high. In this paper we investigate how several factors, such as geologic typologies of the soil and a range of building characteristics, impact on indoor concentration focusing, in particular, on how concentration changes as a function of the floor level. Adopting a mixed effects model to account for the hierarchical nature of the data, we also quantify the extent to which such measurable factors manage to explain the variability of indoor radon concentration. - Highlights: • It is assessed how the variability of indoor radon concentration depends on buildings and lithologies. • The lithological component has been found less relevant than the building one. • Radon-prone lithologies have been identified. • The effect of the floor where the room is located has been estimated. • Indoor radon concentration have been predicted for different dwelling typologies

  9. Protocol for the estimation of average indoor radon-daughter concentrations: Second edition

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.; Pacer, J.C.

    1988-05-01

    The Technical Measurements Center has developed a protocol which specifies the procedures to be used for determining indoor radon-daughter concentrations in support of Department of Energy remedial action programs. This document is the central part of the protocol and is to be used in conjunction with the individual procedure manuals. The manuals contain the information and procedures required to implement the proven methods for estimating average indoor radon-daughter concentration. Proven in this case means that these methods have been determined to provide reasonable assurance that the average radon-daughter concentration within a structure is either above, at, or below the standards established for remedial action programs. This document contains descriptions of the generic aspects of methods used for estimating radon-daughter concentration and provides guidance with respect to method selection for a given situation. It is expected that the latter section of this document will be revised whenever another estimation method is proven to be capable of satisfying the criteria of reasonable assurance and cost minimization. 22 refs., 6 figs., 3 tabs

  10. Study of the effects of atmospheric parameters on ground radon concentration by track technique

    International Nuclear Information System (INIS)

    Tidjani, Adams

    1988-01-01

    Radon emanation was continuously monitored for 24 months, accompanied by measurements of atmospheric parameters. Integrated measurments of radon concentrations have been performed with LR-115 cellulose nitrate track detectors. The monitoring was conducted at 16 sites distributed around the Dakar University area. Observed changes in radon concentration are interpreted as being caused by changes in meteorological conditions and ocean tides. (author)

  11. Radon soil-gas concentration and exhalation from mine tailings dams in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Ongori, J.; Lindsay, R. [University of the Western Cape, Department of Physics, Private Bag X17, Bellville 7535 (South Africa); Newman, R. [Stellenbosch University, Department of Physics, Private Bag X1 Matieland 7602 (South Africa); Maleka, P. [iThemba LABS, Department of Nuclear Physics, P. O. Box 722, Somerset West 7129 (South Africa)

    2014-07-01

    In Africa as well as in the world, South Africa plays an important role in the mining industry which dates back almost 120 years. Mining activities in South Africa mainly take place in Gauteng Province. Every year million of tons of rocks are taken from underground, milled and processed to extract gold. The uranium bearing tailings are disposed in dumpsites. These tailings dumps contain considerable amounts of radium ({sup 226}Ra) and have therefore been identified as large sources of radon ({sup 222}Rn). Radon is a noble gas formed by the decay of radium which in turn is derived from the radioactive decay of uranium ({sup 238}U). Radon release from these tailings dumps pose health concerns for the surrounding communities. Radon soil gas concentrations and exhalations from a non-operational mine dump (Kloof) which belongs to Carletonville Gold Field, Witwatersrand, South Africa have been investigated. The continuous radon monitor, the Durridge RAD7 was used to measure {sup 222}Rn soil gas concentration in the tailings dump at five different spots. The radon soil gas concentration levels were measured at depths starting from 30 cm below ground/air interface up to 110 cm at intervals of 20 cm. The concentrations recorded ranged from 26±1 to 472±23 kBq.m{sup -3}. Furthermore, thirty four soil samples were taken from the spots where radon soil gas measurements were measured for laboratory-based measurement using the low background Hyper Pure Germanium (HPGe) gamma-ray detector available at the Environmental Radioactivity Laboratory (ERL), iThemba LABS, Western Cape Province. The soil samples were collected in the depth range 0-30 cm. After analysis the weighted average activity concentrations in the soils samples were 308±7 Bq.kg{sup -1}, 255±5 Bq.kg{sup -1} and 18±1 Bq.kg{sup -1} for {sup 238}U, {sup 40}K and {sup 232}Th, respectively. A number of factors such as the radium activity concentration and its distribution in soil grains, soil grain size, soil porosity

  12. Influence of ventilation strategies on indoor radon concentrations based on a semiempirical model for Florida-style houses

    International Nuclear Information System (INIS)

    Hintenlang, D.E.; Al-Ahmady, K.K.

    1994-01-01

    Measurements in a full-scale experimental facility are used to benchmark a semiempirical model for predicting indoor radon concentrations for Florida-style houses built using slab-on-grade construction. The model is developed to provide time-averaged indoor radon concentrations from quantitative relationships between the time-dependent radon entry and elimination mechanisms that have been demonstrated to be important for this style of residential construction. The model successfully predicts indoor radon concentrations in the research structure for several pressure and ventilation conditions. Parametric studies using the model illustrate how different ventilation strategies affect indoor radon concentrations. It is demonstrated that increasing house ventilation rates by increasing the effective leakage area of the house shell does not reduce indoor radon concentrations as effectively as increasing house ventilation rates by controlled duct ventilation associated with the heating, ventilating, and air conditioning system. The latter strategy provides the potential to minimize indoor radon concentrations while providing positive control over the quality of infiltration air. 9 refs., 5 figs

  13. Removal of radon decay products with ion generators - comparison of experimental results with theory

    International Nuclear Information System (INIS)

    Maher, E.F.; Rudnick, S.N.; Moeller, D.W.

    1985-01-01

    The potential of ion generators to remove radon decay products from the airspace of residences or mines was investigated both experimentally and theoretically. A positive ion generator, producing an air ion current of less than 2 μA and operated in a 78 m 3 chamber with air exchange rates ranging from 0.2 to 0.8-hr -1 and relative humidities ranging from 20 to nearly 100%, reduced the concentrations of airborne radon decay products by as much as 85%. A negative ion generator, operated under the same range of conditions, was less effective, producing airborne radon decay product removals up to 67%. Experimental results compared favorably with a simple theoretical model that hypothesizes a three-part process: 1) radon decay products, as well as aerosol particles to which some of these decay products attach, are charged by diffusion of the air ions produced by the generator; 2) the air ions also produce a nonuniform space charge in the chamber that results in an electric field gradient radially outwards from the generator to the chamber surfaces; and 3) because of the influence of this electric field, the charged decay products and particles migrate toward nearby surfaces where they plate out. The net benefit of unipolar space charging is a substantial decrease in the steady-state radon decay product concentrations in the airspace with a corresponding reduction in the lung dose equivalent to the occupants

  14. Indoor radon and lung cancer in the radium dial workers

    International Nuclear Information System (INIS)

    Neuberger, J.S.; Rundo, J.

    1996-01-01

    Internally deposited radium has long been known to have tumorigenic effects in the form of sarcomas of the bone and carcinomas of the paranasal sinuses and mastoid air cells. However, the radium dial workers were also exposed to radiation hazards other than that occurring from ingestion of the radium paint, viz., external gamma radiation and elevated concentrations of airborne radon. The uranium miners were also exposed to high concentrations of radon in the 1950s and later, and numerous cases of lung cancer have occurred in that population. However, unlike the atmosphere in the uranium mines, the air in the dial painting plants was probably rather clean and perhaps not much different from the air in many houses. In view of the current concern over the possibility of lung cancer fin the general population being caused by radon (progeny) in houses, it is important to examine the mortality due to this usually fatal disease in the dial workers and to attempt to relate it to their exposure to radon, to the extent that this is possible

  15. 222radon and its alpha decay concentration into university in Cluj

    International Nuclear Information System (INIS)

    Neda, T.; Mocsy, I.; Tonk, S.

    2004-01-01

    The Bocskai house is an old building in the middle of Kolozsvar city. It was built in 1550. Now it host the Hungarian University Rector's Office and the Faculty of Science and Art, after many modifications. The building has 3 levels. We determined the radon activity concentration and the concentrations of its short-lived daughters in 12 different rooms used for education and as office rooms. The measurements were done with ionization chambers in different conditions in 24 h cycle in the period of 2003-2004. Simultaneously we measured ambient temperature, pressure and relative humidity of the air. We found that the radon activity concentration had values between 40 - 1800 Bq.m-3. Based on the measurements we estimated the exposure from radon and its short lived daughters of the people who work in this building. (author)

  16. Measurement of the radon concentration in an underground public facility and dose assessment. Fukuoka Tenjin Shopping Center

    International Nuclear Information System (INIS)

    Narazaki, Yukinori; Tokonami, Shinji; Sanada, Tetsuya; Kanno, Nobuyuki; Yamada, Yuji

    2000-01-01

    Radon concentrations were measured with a passive radon detector from April 1998 through June 1999 in the Fukuoka Tenjin Underground Shopping Center to assess the dose affecting workers because of radon progeny inhalation. The radon concentration during the period was distributed from a range of 1.9 to 13.6 Bq/m 3 . The arithmetic average concentration was estimated to be 6.9±2.4 Bq/ 3 . The radon level was lower than that in dwellings in Japan and other countries. No spatial distribution of radon concentration was found in that area. From continuous measurement, the radon concentration was found to be high from midnight to noon and low in the afternoon. Little difference was noted between the daily average radon concentration and that during working hours. There was no seasonal variation. The equilibrium factor of 0.21±0.10 was obtained during working hours. The activity-weighted size distribution of radon progeny was evaluated by using the number distribution of ambient aerosols and the classical attachment theory. Consequently, the activity median diameter was 150 nm. The unattached fraction of radon progeny was estimated to be 0.025 with an empirical equation. The annual effective dose of workers at the Tenjin center was calculated with the dose conversion factor from the UNSCEAR 1993 report and estimated to be 0.024 mSv/y. (author)

  17. Surface-deposition and distribution of the radon-decay products indoors

    International Nuclear Information System (INIS)

    Espinosa, G.; Tommasino, L.

    2015-01-01

    The exposure to radon-decay products is of great concern both in dwellings and workplaces. The model to estimate the lung dose refers to the deposition mechanisms and particle sizes. Unfortunately, most of the dose data available are based on the measurement of radon concentration and the concentration of radon decay products. These combined measurements are widely used in spite of the fact that accurate dose assessments require information on the particle deposition mechanisms and the spatial distribution of radon decay products indoors. Most of the airborne particles and/or radon decay products are deposited onto indoor surfaces, which deposition makes the radon decay products unavailable for inhalation. These deposition processes, if properly known, could be successfully exploited to reduce the exposure to radon decay products. In spite of the importance of the surface deposition of the radon decay products, both for the correct evaluation of the dose and for reducing the exposure; little or no efforts have been made to investigate these deposition processes. Recently, two parallel investigations have been carried out in Rome and at Universidad Nacional Autónoma de México (UNAM) in Mexico City respectively, which address the issue of the surface-deposited radon decay products. Even though these investigations have been carried independently, they complement one another. It is with these considerations in mind that it was decided to report both investigations in the same paper. - Highlights: • Distribution of Radon and Thoron decay indoor products. • Indoor radon measurements complexity. • Short and long term measurements of surface deposit of Radon and Thoron decay products. • Microclimate controlled conditions room. • Nuclear Tracks Detectors

  18. Measurements of seasonal and daily radon daughter concentration fluctuations in National Park Service caves

    International Nuclear Information System (INIS)

    Yarborough, K.A.

    1977-01-01

    The National Park Service (NPS) is studying levels of airborne alpha radiation from radon and thoron in all NPS administered caves in which tours for visitors are regularly conducted. The NPS research has the dual but complementary objectives of safeguarding health at the NPS administered caves, and to develop data on alpha radiation levels and on natural airflows in NPS caves. The results reported here for NPS caves describe concepts hypothesized for the objectives. In addition the data can be used by various agencies to clarify health standards for exposures to low airborne alpha radiation levels in cave environments. These results show daily and seasonal trends and the influence of natural ventilation by air circulation for each cave investigated

  19. Radon concentrations in Norwegian kindergartens: survey planning and preliminary results

    International Nuclear Information System (INIS)

    Birovljev, A.; Strand, T.; Heiberg, A.

    1998-01-01

    An extensive radon survey in Norwegian kindergartens and schools was started in early 1997; so far 2481 kindergartens were examined. Preliminary results of the first phase of the survey are presented in tabular and graphic form including, among others, the dependence of average radon concentration on the construction year of the kindergartens and on the age of the buildings. (A.K.)

  20. Studies on spatial distribution of indoor radon concentration at Mysore city, India

    International Nuclear Information System (INIS)

    Pruthvi Rani, K.S.; Chandrashekara, M.S.; Paramesh, L.

    2016-01-01

    Radon is a radioactive inert gas, with a half life of 3.82 days. Radium present in soil rocks and building material are the sources of atmospheric radon. Radon and its short-lived decay products ( 218 Po, 214 Pb, 214 Bi, and 214 Po) can be deposited in the lung tissues and give rise to higher radiation doses. Radon is now recognized as the second most important cause of lung cancer after smoking in the general population. In the present investigation a systematic study of the distribution of radon concentration has been carried out in a small room at different co-ordinates and time scales

  1. Tempts to determine radon entry rate and air exchange rate variable in time from the time course of indoor radon concentration

    International Nuclear Information System (INIS)

    Thomas, J.

    1996-01-01

    For the study and explanation of the diurnal variability of the indoor radon concentration a(t) [Bq/m 3 ], which is proportional to the ratio of the radon entry rate A [Bq/h] and the air exchange rate k [1/h], it would be of advantage to know separately the diurnal variability of both determining quantities A(t) and k(t). To measure directly and continuously the radon entry rate A(t) is possible only in special studies (mostly in experimental rooms) and also continuous measuring of the air exchange rate k(t) is possible also only in special studies for a short time. But continuously measuring radon meters are now common, do not trouble people in normal living regime during day and night. The goal of this endeavour would be the evaluation of the time courses of both determining quantities from the time courses of the indoor radon concentration directly without additional experimental work and so a better utilisation of such measurements. (author)

  2. Protocol Implementation for Radon Concentration Measurements in Houses in Croatia - Baranja Case

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Varga Pajtler, M.; Vukovic, B.

    2011-01-01

    The newly established protocol for radon measurements in homes was implemented on the radon survey in houses of Baranja region which was carried out from July 2009 until July 2010. The radon measurements were performed with passive track etched detectors. The method consists of cylindrical plastic vessel and two strippable LR-115 films type II (Kodak-Path, France). This method with two detector films enables the estimation of equilibrium factor as well.Croatian territory is divided in 10 x 10 km 2 cells which were part of a reference grid map which is used in a preparation of European radon concentration map. Detector locations were randomly chosen inside each grid and their number was determined by the number of inhabitants inside (one locations per 350 inhabitants). Radon detectors were exposed for a year in a living room or a bedroom away from strong ventilation and 30 cm from side walls (usually on closet at height of 2 m). After the exposure, detectors were collected and etched in 10 % NaOH aqueous solution at 50 degrees of C for 180 minutes. The tracks were automatically counted using spark counter AIST-2V. The obtained results were in the range from 6 to 355 Bq m -3 with arithmetic mean of 88 Bq m -3 and standard deviation of 69.0 Bq m -3 . The geometric mean was 67.2 Bq m -3 while the geometric standard deviation was 2.1 Bq m -3 . The statistical χ2 -test showed that the empirical frequency distribution for radon in houses of Baranja region belonged to the log-normal distribution. The percentage of houses with radon concentrations between 200 and 400 Bq m -3 was 6.7% and 1.0% of houses have radon concentration above 400 Bq m -3 . The annual effective dose from the indoor radon and its short-lived progenies for the inhabitants of Baranja region (for the average equilibrium factor of 0.53 and occupancy factor of 0.6) was 1.5 mSv. (author)

  3. A study on the indoor radon concentrations in hospitals in the Shillong region, Meghalaya

    International Nuclear Information System (INIS)

    Sharma, Yubaraj; Maibam, Deveshwori; Saxena, Atul; Ram, Priya P.; Walia, Devesh

    2015-01-01

    In this paper, we report our findings on radon survey in indoor environment which consists of around 105 rooms in 8 major hospitals in Shillong region and also present experimental estimates on the associated annual effective doses and life-time fatality risks. The survey has been undertaken using LR-115 Type 2 detectors. Radon activity concentration values were found to range from 65.66 Bq.m -3 to 783.77 Bq.m -3 with an arithmetic mean value of 260.4±138.3 Bq.m -3 and a geometric mean value of 228.4±1.67 Bq.m -3 . Distribution analysis of the radon activity concentration measured at the hospital rooms has been carried out. Of the total rooms surveyed, 60% have radon concentration more than the ICRP prescribed lower limit of 200 Bq.m -3 and about 4% of the rooms higher than the upper limit of 600 Bq.m -3 . Floor-wise study has been done and a decrease in radon concentration with increase in floor-number has been observed. (author)

  4. Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo

    International Nuclear Information System (INIS)

    Tokonami, S.; Furukawa, M.; Shicchi, Y.; Sanada, T.; Yamada, Y.

    2003-01-01

    A series of measurements were carried out to understand the characteristics of radon and its progeny in air-conditioned office buildings. Long-term measurements of radon were made with etched track detectors. Continuous measurements of radon and its progeny concentrations were also conducted in some buildings to study their temporal variations. The results show that radon and its progeny concentrations routinely varied along with working activities. They are generally low while people are working, due to air conditioning, whereas they rise steadily after the air conditioning stops. When considering action levels not only in homes but also workplaces, attention should be paid to annual doses from the viewpoint of radiation protection. The annual dose is generally estimated with a long-term measurement of radon concentration using a passive device such as an etched track detector. Since its reading corresponds to a long-term average concentration regardless of working hours, the annual dose will be overestimated. When comparing a real dose after considering the working hours, they differ by a factor of more than 2. (author)

  5. Radon concentrations in homes in an area of dolomite bedrock: Door County, Wisconsin

    International Nuclear Information System (INIS)

    Hawk, K.; Stieglitz, R.D.; Norman, J.C.

    1993-01-01

    A statewide survey by the Wisconsin Department of Health and Social Services with U.S.E.P.A. assistance reported an anomalously high percentage of homes in Door County with radon concentrations in excess of 20 pCi/L. The results were of interest because the county is underlain by marine sedimentary rocks rather than the igneous and metamorphic crystalline types usually associated with elevated radon concentrations. A voluntary population of 55 homes was tested for radon using activated charcoal canisters. This population was also asked to provide questionnaire response data on family, home, and socioeconomic aspects. The data were separated into socioeconomic, energy efficiency, radon access, and karst level categories and statistically analyzed. A subpopulation was selected from the larger population for detailed site investigation, which included additional in-home air testing and, at some sites, water supply analysis and in-ground testing for radon. The field investigations collected information on the geology, soil, topography, and home construction and use. The results of the investigation verified and characterized the radon occurrences in Door County. The presence or absence of karst features is shown to be statistically significant to radon levels. 23 refs., 5 figs., 3 tabs

  6. Measurement of radon concentration in ground water at Saijo sake brewery by means of γ-ray spectrometry

    International Nuclear Information System (INIS)

    Takenaka, Kodai; Takatori, Hiroshi; Kojima, Yasuaki; Shizuma, Kiyoshi

    2008-01-01

    Recently, natural water such as ground water and/or spring water of various places is popular for the environmental preservation and safety of food. Measurement of the radon concentration in ground water is important for risk estimate of drinking water and whether the water can be authorized as the mineral spring (74 Bq/L). In this work, radon concentration is ground water from eight places which were utilized for Saijo sake breweries was measured by means of γ-ray spectrometry. Radon concentration in each well was measured every month for two years. The variation in the radon concentration was investigated for seasonal variation, difference between the type of well, correlations with pH, water temperature and atmospheric temperature. The results are as follows: An average value of the radon concentration was 160 Bq/L which meant most of ground water satisfies the mineral spring standard. The radon concentration of the drilling well was higher than that of the punched well. The variation in the radon concentration shows no seasonal variations, nor depends on the water temperature, the atmospheric temperature and the pH. (author)

  7. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  8. Determination of radon concentration in soil gas by gamma-ray spectrometry of olive oil

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish; Karunakara, N.

    2007-01-01

    Measurements of radon concentration in soil gas have been carried out using a bubbling system in which the soil gas is drawn through an active pumping to bubble a liquid absorber (olive oil) for the deposition of the soil gas in it. After the bubbling process, the absorber is then taken for gamma-ray measurements. Gamma-ray photopeaks from the 214 Pb and the 214 Bi radon progeny are considered for the detection of the 222 Rn gas to study the concentration levels for radon soil gas. Results for some field measurements were obtained and compared with results obtained using AlphaGuard radon gas monitor. The technique provides a possible approach for the measurements of radon soil gas with gamma-ray spectrometry

  9. Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine

    International Nuclear Information System (INIS)

    Dabyneh, K.M.

    2006-01-01

    In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m 3 with an average of 34.1 Bq/m 3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in Tarqumia secondary girls school, Al-aqsa elementary girls school, Umsalama elementary girls school and Tarqumia elementary girls school were 35.8, 26.7, 25.9 and 47.8 Bq/m 3 , respectively, and the mean values of the annual effective dose equivalent for the above mentioned were 1.85, 1.38, 1.34 and 2.47 mSv/y, respectively. It has been found from these results that, most of the values were of nominal state values (that is less than the allowed global values) and in few places, the concentration was higher than the allowed global values, therefore, the annual effective dose higher than annual global level values (1.3 mSv/y) was resulted. Poor ventilation and old buildings were, most mobility, the main cause of these high radon concentrations. Improving ventilation of these places will increase air exchange rates with the out side, thereby resulting in reduced concentration. In general, the results showed that protection against radiological hazards would not be necessary for pupils and staff members occupying the rooms of the investigated schools

  10. Develop generic equations to determine radon daughters concentrations in air

    International Nuclear Information System (INIS)

    Shweikani, R.; Jerby, B.

    2011-06-01

    Measurements of radon daughter concentrations in air are very important to determine the human dose from background radiation. Therefore, many studies tried to find measurements methods depending on many specific parameters such as measurement time, air pumping period and sample volume. In this study a general equations to determine radon daughter's concentrations in air was found using direct samples. The Equations results were closed to the results obtained from other well known methods. Many measurements with different places and various conditions were performed; the results showed that the new equations are able to be used with an error less than 10%, The relative error can be reduced by increasing the pumping rate or measuring high concentration cases.(author)

  11. Airborne plutonium and americium concentrations measured from the top of Rattlesnake Mountain

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1979-01-01

    Airborne plutonium-239+240 and americium-241 blowing from offsite was measured in an initial experiment at the top of Rattlesnake Mountain. Average airborne concentration measured was similar to fallout concentrations. Airborne plutonium concentrations were independent of wind speed for seven wind speed increments between 0.5 and 31 m/sec. In contrast the airborne americium concentration was a minimum at a wind speed of approximately 7 m/sec. Similarly, the airborne solids concentration in μg/m 3 was a minimum at an intermediate wind speed increment of 7 to 11 m/sec

  12. Investigation of indoor radon concentration in block houses in Omderman

    International Nuclear Information System (INIS)

    Ahmed, H. A. M.

    2010-12-01

    Radon is one of the naturally occurring radioactive elements in the environment as a member of the natural uranium decay. Exposure to radon in the home and workplace is one of the main risks of ionizing radiation thought to cause tens of thousands of deaths from lung cancer each year. In order to reduce this burden it is important that national authorities have methods and tools bases on solid scientific evidence and sound public health policy. The public needs to be aware of radon risks and the means to reduce and prevent these. This study presents of the studies dealing with the investigation of exposure from ionizing radiation. The radon levels in some selected type of building styles (Bricks Albulk) were investigated in Omderman city (public housing). The radon level in most of the houses found to range between 87.63 and 206 Bq/m 3 with average value of 127±23 Bq/m 3 . This is well lay within the allowable limit with average. The study indicates that building materials used does not add significant concentration of radon to indoor. It can be considered as safe type of building style from radiation protection point of view. (Author)

  13. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Onuma, A.; Shimizu, M.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan)); Kagami, T.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method.

  14. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    International Nuclear Information System (INIS)

    Onuma, Akiko; Shimizu, Michihiko; Chaya, Kunio; Hamamura, Norikatsu; Kagami, Tadaaki.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method. (J.P.N.)

  15. Evaluation of radon concentration in well and tap waters in Bursa (Turkey)

    International Nuclear Information System (INIS)

    Akar Tarim, U.; Gurler, O.; Akkaya, G.; Kilic, N.; Yalcin, S.; Kaynak, G.; Gundogdu, O.

    2012-01-01

    222 Rn measurements in water samples collected from 27 wells and 19 taps that were supplied from the investigated wells were conducted using the AlphaGUARD PQ 2000PRO radon gas analyser at sites across several geologic formations within the city of Bursa (Turkey). The measured radon concentrations ranged from 1.46 to 53.64 Bq l -1 for well water and from 0.91 to 12.58 Bq l -1 for tap water. Of the 27 sites sampled, only 7 had radon levels above the safe limit of 11.1 Bq l -1 recommended by the USEPA. In general, all determined concentrations were well below the 100 Bq l -1 revised reference level proposed by the European Union. These values of radon concentrations in water samples are compared with those reported from other countries. Doses resulting from the consumption of these waters were calculated. The minimum and the maximum annual mean effective doses due to 222 Rn intake through water consumption were 0.02 μSv a -1 and 1.11 μSv a -1 , respectively. (authors)

  16. Radon concentrations inside castles and other ancient buildings

    International Nuclear Information System (INIS)

    Malanca, A.; Pessina, V.; Dallara, G.

    1992-01-01

    Sixty-two measurements of Rn-222 concentrations were made in 24 castles and 13 ancient buildings in 30 different places situated in the provinces of Parma and Reggio Emilia (Northern Italy). The method used was that of activated carbon canisters which were placed in selected settings for at least 48 h in the period staring from December 1990 to May 1991. It was possible to determine the amount of radon in each canister via its daughters gamma emitters counted by Nal(Tl) and Ge(I) detectors. The mean radon concentrations were 72 Bq m -3 (arithmetic mean) and 49 Bq m -3 (geometric mean), a good deal higher than the values obtained from measurements carried out in modern dwellings in the same area; 30 Bq m -3 (arithmetic mean) and 19 Bq m -3 (geometric mean). (author). 20 refs., 2 figs., 6 tabs

  17. Determination of radon and radium concentrations in drinking water samples around the city of Kutahya

    International Nuclear Information System (INIS)

    Sahin, L.; Cetinkaya, H.; Murat Sac, M.; Ichedef, M.

    2013-01-01

    The concentration of radium and radon has been determined in drinking water samples collected from various locations of Kutahya city, Turkey. The water samples are taken from public water sources and tap water, with the collector chamber method used to measure the radon and radium concentration. The radon concentration ranges between 0.1 and 48.6±1.7 Bq l -1 , while the radium concentration varies from a minimum detectable activity of -1 in Kutahya city. In addition to the radon and radium levels, parameters such as pH, conductivity and temperature of the water, humidity, pressure, elevation and the coordinates of the sampling points have also been measured and recorded. The annual effective dose from radon and radium due to typical water usage has been calculated. The resulting contribution to the annual effective dose due to radon ingestion varies between 0.3 and 124.2 μSv y -1 ; the contribution to the annual effective dose due to radium ingestion varies between 0 and 143.3 μSv y -1 ; the dose contribution to the stomach due to radon ingestion varies between 0.03 and 14.9 μSv y -1 . The dose contribution due to radon inhalation ranges between 0.3 and 122.5 μSv y -1 , assuming a typical transfer of radon in water to the air. For the overwhelming majority of the Kutahya population, it is determined that the average radiation exposure from drinking water is less than 73.6μmSv y -1 . (authors)

  18. Field applications of a radon barrier to reduce indoor airborne progeny

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1978-01-01

    The use of uranium mill tailings in the foundations of dwellings has resulted in indoor radon progeny concentrations and gamma exposures in excess of levels presently allowed for the general public. An account is given of the applications of an epoxy coating on the indoor faces of the concrete foundations of three buildings in Grand Junction, Colorado. Epoxy barriers were shown to be effective for preventing radon influx into structures. Gamma exposure rates must be analyzed to ensure that buildup behind the barrier will not introduce an unacceptable gamma exposure level. The use of a sealant is especially economical in situations where structural integrity may be jeopardized by physical removal of uranium mill tailings. (author)

  19. A study on the radon concentrations in water in Jeddah (Saudi Arabia) and the associated health effects

    International Nuclear Information System (INIS)

    Tayyeb, Z.A.; Kinsara, A.R.; Farid, S.M.

    1998-01-01

    Several studies have shown that water-borne 222 Rn contributes to indoor air concentrations. A passive radon measurement method was employed to determine radon activity concentrations in the water of Jeddah city (Saudi Arabia). Tap water, flushing water and drinking water, including natural mineral water, artificial mineral water and distilled water, have been investigated for their radon concentrations. It is observed that the radon concentration in natural mineral water samples is the highest and that in flush water, it is the lowest. From these measurements, the corresponding annual effective dose for the stomach and the lung are determined. It is found that the annual effective dose resulting from direct consumption of water is far greater than that due to inhalation of radon emanated from tap water and flushing water. Moreover, it is also seen that the annual effective dose resulting from inhalation of radon emanated from tap water and flushing water is negligible compared to the total annual effective dose for indoor radon in Jeddah. (author)

  20. Investigations on indoor radon in Austria, Part 1: Seasonality of indoor radon concentration

    International Nuclear Information System (INIS)

    Bossew, Peter; Lettner, Herbert

    2007-01-01

    In general, indoor radon concentration is subject to seasonal variability. The reasons are to be found (1) in meteorological influence on the transport properties of soil, e.g. through temperature, frozen soil layers and soil water saturation; and (2) in living habits, e.g. the tendency to open windows in summer and keep them closed in winter, which in general leads to higher accumulation of geogenic Rn in closed rooms in winter. If one wants to standardize indoor Rn measurements originally performed at different times of the year, e.g. in order to make them comparable, some correction transform as a function of measurement time which accounts for these effects must be estimated. In this paper, the seasonality of indoor Rn concentration measured in Austria is investigated as a function of other factors that influence indoor Rn. Indoor radon concentration is clearly shown to have seasonal variability, with higher Rn levels in winter. However, it is complicated to quantify the effect because, as a consequence of the history of an Rn survey, the measurement season maybe correlated to geological regions, which may introduce a bias in the estimate of the seasonality amplitude

  1. Indoor radon concentrations in the coastal and central regions of Montenegro

    International Nuclear Information System (INIS)

    Vukotic, Perko; Antovic, Nevenka; Svrkota, Ranko

    2008-01-01

    This paper presents the results of the first systematic indoor radon survey in Montenegro, in 10 municipalities of its coastal and central regions. In rural areas one home was randomly selected in each 5 x 5 km square of a regular grid covering the territory of Montenegro, while in urban areas the basic grid was subdivided into 0.5 x 0.5 km squares, and in each of them one building was selected and one dwelling within the building. In each of these 434 homes, radon measurements were performed twice a year, using passive dosimeters placed in the living room or bedroom on the ground floor or the first floor. The CR-39 nuclear track detectors were exposed each time for about six months. The annual average radon concentrations in the surveyed homes are found to be log normally distributed (GM = 49.6 Bq m -3 , GSD 3.2) within the range 2-2,208 Bq m -3 . Their arithmetic mean is 105 Bq m -3 and median 41.4 Bq m -3 . Radon concentrations above the action level of 400 Bq m -3 are detected in 5.6% of the surveyed homes. Most of these 24 homes are detached single-family houses, and the majority are rural. Radon concentrations were generally higher in detached family houses than in apartment buildings, in older than in newer houses, and higher in rural than in urban homes. As to the domestic radon exposure, this survey indicates reinforced concrete as the most favorable and stones as the most unfavorable of the building materials commonly used in Montenegro. The lowest average effective dose is in urban homes on the Montenegrin Coast (0.80 mSv y -1 ), while the highest is in the rural area of the Niksic municipality (7.31 mSv y - 1 ) , which is abundant in bauxite deposits. (author)

  2. Surface deposition of radon decay products with and without enhanced air motion

    International Nuclear Information System (INIS)

    Rudnick, S.N.; Maher, E.F.; Hinds, W.C.; First, M.W.

    1983-01-01

    The effectiveness of fan-induced air motion in reducing airborne activity of short-lived radon decay products was evaluated in a 78-m 3 chamber. Observed reductions were as high as 50% for RaA ( 218 Po), 79% for RaB ( 214 Pb), and 86% for RaC ( 214 Bi). Activity Measurements of these nuclides on chamber and fan surfaces, along with airborne activity, were used to calculate material balances. Greater than about 90% of deposited activity was found on chamber surfaces, although areal activity density was higher on fan surfaces. Deposition velocity and diffusional boundary thickness were also determined. When no fans were used, boundary layer thickness was estimated to be 25 times the recoil distance of a RaB atom and, with fans, about 4 times the recoil distance, suggesting that recoiling of RaB atoms probably do not play a significant role in the relationship between surface and airborne activity. The results of this study have relevance for all habitable spaces having excessive radon concentration

  3. Determination of the radon Concentration in underground water in selected areas in and around Kumasi

    International Nuclear Information System (INIS)

    Owusu, Seth Adjei

    2012-06-01

    Radon (Rn-222) is a radioactive noble gas of natural origin that may be found anywhere in soil, air and different types of water: surface, borehole, well and spring. It is worth to carry out surveys for the radon in water for radiation protection as well as for geological considerations. The research presenters here was carried out in selected towns in and around Kumasi for the determination of radon concentration in groundwater. The major towns from which samples were taken are , Mowire, Kronum, Aburaso, Medoma, Kenyase, Buokrom, Bomfa, Ayeduase, Kotei, Tikrom. All the samples are used for domestic purposes such as cooking, drinking, bathing and washing. Waters from boreholes and wells in the selected towns were sampled and the radon concentration level measured. The Roll’s method was used for the radon concentration analysis on all the 100 samples. The results shows that, the minimum radon concentration in groundwater was 13015.934 Bq/m3 and it was found at Bomfa, and the highest was found to be 964628.480 Bq/m3, recorded at Mowire. It is believed that this variation of levels is mainly due to the difference in rock type, soil type and geology of the area as well as the depth of the water samples. This information can be used to estimate the possible health hazards from radon in the selected towns in the future from environmental point of view. The data would promote public awareness related to risk of radon exposure. (au)

  4. Distribution of indoor radon concentrations and elements of a strategy for control

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1986-05-01

    Indoor radon concentrations vary widely in the US housing stock, with normal concentrations estimated to cause a significant risk of lung cancer by comparison with environmental exposures normally considered, and high concentrations causing risks that exceed even those from cigarette smoking. The probability distribution, i.e., the number of houses at various concentrations, can be estimated from an analysis of the US indoor radon data accumulated to date. Such an analysis suggests that in about a million houses, occupants are receiving exposures greater than those experienced by uranium miners. The form of the frequency distribution, including not only the average concentration, but also the number of houses with high levels, has substantial influence on strategies for control of indoor radon. Such strategies require three major elements: formulation of control objectives in terms of guidelines for remedial action and for new houses; selection of means for identifying homes with high concentrations; and a framework for deciding what types of control measures are appropriate to particular circumstances and how rapidly they should be employed

  5. Radon as an environmental risk: concentration measurements in family buildings at Cordoba city

    International Nuclear Information System (INIS)

    Bonzi, A.; Murua, C.; Martin, H.R.

    1992-01-01

    Measurements of radon concentration at homes are usual activities in the last years at the countries with uranium in their soils. On the other hand, the man's radiological protection about radiation is related to the environmental actions for a healthy life, but not much known for a public. The great quantities of ore with uranium can be an important source of irradiation when they are used as building materials. The soils are important too for the emanations of radon in the interior of buildings and for these reasons, the radon concentration measurements in Cordoba familiar houses were implemented in the summer of 1991. The Alpha Track Technique and the results obtained indicate the need of other measurements and a winter measurement for investigation variations of radon concentration. The typical values measured were low, about 4.13 Bq/m 3 if they are compared with other Argentine values measured. This paper discusses the procedure, techniques and criteria used in the work held in Cordoba city, Argentina. (Author)

  6. Study and development of an airborne instrument for collecting aerosols and for measuring radon 222 by its active deposition

    International Nuclear Information System (INIS)

    Filippi, Dominique

    2000-01-01

    The study and development of an airborne instrument designed to collect aerosols and measure radon 222 is detailed in this thesis. Having discussed the context of radon and introduced the methods of the measurement of radon 222 by its natural active deposition, the measurement of aerosols with the Sextant Avionique/LSCE dynamic iso-kinetic probe is quantified. These estimations of the efficiency of the probe were obtained during iso-axial simulations of the flow around the probe at different sub-sonic speeds, then by the calculation of trajectories of particles at the entrance to the probe for several debit coefficients. The effect of the attack angle is discussed along with the iso-kinetic criteria of pressure necessary for the functioning of this probe. To conclude this theoretical study, the author has estimated the deposits during aerosol transport in pipes. The instrument once constructed, (dubbed A VIRAD), is then itself presented, along with the technological aspects adopted for its use. The instrument was validated during an experimental aerial study STAAARTE 99. The measures obtained during these flights are presented in the conclusions. (author) [fr

  7. Measurement of concentrations of radon and its daughters in indoor atmosphere using CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Khan, A.J.; Sharma, K.C.; Varshney, A.K.; Prasad, Rajendra; Tyagi, R.K.

    1988-01-01

    The concentrations of radon and its daughters in rooms having different environmental conditions are measured using CR-39 nuclear track detector. It has been found that the radon concentration inside the rooms depends on ventilation, sub-soil emanation and the housed materials. The use of internal wall coverings such as plaster, distemper and white washing may reduce the radon emanation inside the rooms. The use of paints on walls is the best for reducing the radon concentration inside the rooms. (author). 11 refs

  8. Low air exchange rate causes high indoor radon concentration in energy-efficient buildings

    International Nuclear Information System (INIS)

    Vasilyev, A.V.; Yarmoshenko, I.V.; Zhukovsky, M.V.

    2015-01-01

    Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low. (authors)

  9. Distribution of radon concentration in residences and others buildings of Belo Horizonte city, MG, Brazil

    International Nuclear Information System (INIS)

    Santos, Talita de Oliveira

    2010-01-01

    Human beings are exposed to ionizing radiation from many natural sources. Radon and its progeny have been recognized as the most important contributors to the natural radioactivity dose, accounting for about half of all human exposure to ionizing radiation. Radon is a α-radioactive noble gas derived from the natural series of uranium and thorium, which occurs in a wide concentration range in all geological materials, especially, in rocks, soils and waters. By diffusion and convection, radon migrates from the rocks and soils to atmosphere and through fissures, pipes and holes it may enter the dwellings and other buildings. Another important radon source in dwellings is its emanation from the construction material. The radon progeny concentration in dwellings has been receiving considerable global attention due to its potential effect in causing lung cancer if it deposited in upper respiratory tract when inhaled. This work presents radon concentration distribution in dwellings in Metropolitan Region of Belo Horizonte - RMBH. The geological settings of the area are Archean rocks of Granitic Gneissic Complex and of metasediments sequences of the great Precambrian unit of the Iron Quadrangle of Minas Gerais, Brazil. Radon concentration measurements were carried out with continuous detector AlphaGUARD PQ200PRO (Genitron), in passive mode and with passive detectors E-PERM Electrets Ion Chamber-EIC. The radon progeny concentration was carried out with a solid state alpha spectroscope, the DOSEman PRO (Sarad). It was found an indoor radon concentration varying in a large range from 4 to 2664,0 Bq.m"-"3, with an average value of 108.0 Bq.m"-"3, median of 70 Bq.m"-"3, geometric mean equal to 76 Bq.m"-"3 and standard deviation of 170 Bq.m"-"3. About 15% of the results are over the United States Environmental Protection Agency (U.S. EPA) actions level, which is 148 Bq.m"-"3.The equilibrium factor between radon and its progeny were determined in dwellings, as 0.3 in average

  10. Concentration and distribution of 210Po in rats exposed to radon

    International Nuclear Information System (INIS)

    Pan Peng; Yang Zhanshan; Wang Tianchang; Tong Jian; Zhou Jianwei

    2007-01-01

    Objective: To study the concentration and distribution of 210 Po in rats exposed to radon and its daughters. Methods: Fifteen male wistar rats were randomly divided into three groups, including one control group and two radon exposed groups with the cumulative doses of 100 WLM (low dose) and 200 WLM (high dose), respectively. Tissue samples containing 210 Po were spontaneously deposited onto silvery discs with the diameter of 20 mm by means of wet ashing and electrodeposition. The concentration of 210 Po in tissues were measured by α spectroscopy, and tissue burden were calculated. Results: The concentrations of 210 Po were significantly different among the three dose groups in femur, liver, sex gland and hair (P 210 Po were different between the exposed groups and the control group in lung and soleus muscle (P 210 Po in lung, spleen and hair were higher than that in liver, bone and sex gland, the lowest was in intestine. The tissue burdens of liver, bone and sex gland were significantly different from those in other organs or tissues. Conclusions: 210 Po was mainly distributed in lung, liver, spleen, femur and sex gland. The concentrations of 210 Po in organs or tissues and the tissue burdens were correspondingly increased with the exposure dose of radon and its daughters. The results of this experiment provide a dosimetric basis for further studies on the carcinogenic effect of radon and its daughters. (authors)

  11. Radon concentration and exhalation rates in building material samples from crushing zone in Shivalik Foot Hills

    International Nuclear Information System (INIS)

    Pundir, Anil; Kamboj, Sunil; Bansal, Vakul; Chauhan, R.P.; Rana, Rajinder Singh

    2012-01-01

    Radon ( 222 Rn) is an inert radioactive gas in the decay chain of uranium ( 238 U). It continuously emanates from soil to the atmosphere. Radon and its progeny are the major natural radioactive sources for the ambient radioactivity on Earth. A number of studies on radon were performed in recent decades focusing on its transport and movement in the atmosphere under different meteorological conditions. Building materials are the main source of radon inside buildings. Some construction materials are naturally more radioactive and removal of such material from the earth's crust and their subsequent use in construction of buildings further enhances the radioactivity level. The knowledge of radioactivity level in the building materials makes us aware about the management, guidelines and standards in construction of buildings. The main objective of the present investigations is to measure radon Concentration and exhalation rates in the samples collected from the Crushing zone of Shivalik foot hills. Different types of materials are being used in Northern part of India for construction of dwellings. For the measurement of radon concentration and its exhalation rates in building materials, LR-115 detectors were exposed in closed plastic canisters for three months. At the end of the exposure time, the detectors were subjected to a chemical etching process in 2.5N NaOH solution. The tracks produced by the alpha particles were observed and counted under an optical Olympus microscope at 600X. The measured track density was converted into radon concentration using a calibration factor. The surface and mass exhalation rates of radon have also been calculated using present data. The results indicate that the radon concentration varies appreciably from sample to sample and they were found to satisfy the safety criteria. There are samples in which radon concentration is higher and may enhance the indoor radiation levels when used as building construction materials. (author)

  12. Investigation of indoor radon concentration in block houses in Omderman

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, H A. M. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radon is one of the naturally occurring radioactive elements in the environment as a member of the natural uranium decay. Exposure to radon in the home and workplace is one of the main risks of ionizing radiation thought to cause tens of thousands of deaths from lung cancer each year. In order to reduce this burden it is important that national authorities have methods and tools bases on solid scientific evidence and sound public health policy. The public needs to be aware of radon risks and the means to reduce and prevent these. This study presents of the studies dealing with the investigation of exposure from ionizing radiation. The radon levels in some selected type of building styles (Bricks Albulk) were investigated in Omderman city (public housing). The radon level in most of the houses found to range between 87.63 and 206 Bq/m{sup 3} with average value of 127{+-}23 Bq/m{sup 3}. This is well lay within the allowable limit with average. The study indicates that building materials used does not add significant concentration of radon to indoor. It can be considered as safe type of building style from radiation protection point of view. (Author)

  13. Measurement of indoor radon-thoron and their progeny levels in dwellings and radon concentrations in ground water of Hassan city, Karnataka, India

    International Nuclear Information System (INIS)

    Srinivasa, E.; Rangaswamy, D.R.; Sannappa, J.

    2014-01-01

    The indoor radon and thoron concentrations in dwellings of Hassan city have been measured by using LR-115 type-Il Solid State Nuclear Tracks Detectors (SSNTDs). Measurements were carried in summer season from March to May-2013. The radon and thoron activity concentration in the corresponding dwellings has been found to vary from 7.4 to 45.7 Bqm -3 and 5.4 to 34.9 Bqm -3 with a median of 23.59±11 Bqm -3 and 14.47±8 Bqm -3 respectively. The overall average radon concentrations are found to be less than the lower reference level of 200 Bq m -3 of the International Commission on Radiological Protection. The annual effective dose received due to radon and its progeny by the inhabitants in the dwellings under study has also been calculated which found to vary from 0.320 ±0.4 to 1.86 ±1.1 mSv y -1 with an average value of 0.957±0.8 mSv -1 . The obtained results are much lower than the upper reference level of 10 mSv y -1 (ICRP 2007). Radon in bore well water at different locations of Hassan city was determined using the emanometry technique and exposure dose from ingestion of drinking water was estimated. The radon concentration in ground water was found to vary from 19.49 to 60.74 Bq l -1 with an average value of 47.16±14Bq l -1 . From this study it is evident that, the recorded ground water radon concentration values are higher than MCL of 11 Bq l -1 proposed by USEPA. The total dose due to inhalation and ingestion of 222 Rn in ground water ranges from 0.053 mSv y -1 to 0.165mSv y -1 with an average value of 0.127±0.038mSv y -1 . (author)

  14. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Introduced with a brief discussion of the key role of ventilation in controlling mine atmospheres, the effects of the design of the ventilation system on the control of radon daughter concentrations are illustrated with specific reference to Alcan's Director Mine, St-Lawrence, Nfld. (This fluorspar mine was found to have high radon concentrations due to mine water bringing in dissolved radon.) After a discussion of the health physics history of the mine, the various phases of the ventilation system design and the general results are detailed. The author draws some conclusions having general application to the design of any mine with a radon or thoron daughter concentration. These include minimizing the 'age' of the air; the need for continuous ventilation in all areas; the value of remote control and monitoring; and the benefits of mine pressurization

  15. Preliminary results on variations of radon concentration associated with rock deformation in a uranium mine

    Science.gov (United States)

    Verdoya, Massimo; Bochiolo, Massimo; Chiozzi, Paolo; Pasquale, Vincenzo; Armadillo, Egidio; Rizzello, Daniele; Chiaberto, Enrico

    2013-04-01

    Time-series of radon concentration and environmental parameters were recently recorded in a uranium mine gallery, located in the Maritime Alps (NW Italy). The mine was bored in metarhyolites and porphyric schists mainly composed by quartz, feldspar, sericite and fluorite. U-bearing minerals are generally concentrated in veins heterogeneously spaced and made of crystals of metaautunite and metatorbernite. Radon air concentration monitoring was performed with an ionization chamber which was placed at the bottom of the gallery. Hourly mean values of temperature, pressure, and relative humidity were also measured. External data of atmospheric temperature, pressure and rainfall were also available from a meteorological station located nearby, at a similar altitude of the mine. The analysis of the time series recorded showed variation of radon concentration, of large amplitude, exhibiting daily and half-daily periods, which do not seem correlated with meteorological records. Searching for the origin of radon concentration changes and monitoring their amplitude as a function of time can provide important clues on the complex emanation process. During this process, radon reaches the air- and water-filled interstices by recoil and diffusion, where its migration is directed towards lower concentration regions, following the local gradient. The radon emanation from the rock matrix could also be controlled by stress changes acting on the rate of migration of radon into fissures, and fractures. This may yield emanation boosts due to rock extension and the consequent crack broadening, and emanation decrease when joints between cracks close. Thus, besides interaction and mass transfer with the external atmospheric environment, one possible explanation for the periodic changes in radon concentrations in the investigated mine, could be the variation of rock deformation related to lunar-solar tides. The large variation of concentration could be also due to the fact that the mine is

  16. Analysis of radon concentrations in drinking water in Erbil governorate (Iraqi Kurdistan) and its health effects

    International Nuclear Information System (INIS)

    Ismail, Asaad H.; Haji, Salih O.

    2008-01-01

    Full text: This paper presents the results of radon level in drinking water in Erbil governorate and its districts. The measurements were carried out on 42 samples (tap water) of 21 major areas, and alpha track detectors (type Cr-39) were used for the estimations. The average values for radon concentration of tap water were variable from the district to another, and it was found to be (4.693±2.213 Bq/L) with a maximum of 9.61 Bq/L in Hugran region and minimum of 2.01 Bq/L in Haji-Omaran city. In addition, the average annual effective doses, and equilibrium factor between radon and its daughter were measured in each area and it was found to be (11.546±8.566 μSv/Yr) and (0.204±0.06) respectively. On the other hand, this paper presents an evaluation of the inhalation and ingestion doses from exposure to radon and also the contribution of radon concentration in drinking water to indoor radon concentration was estimated. When the results were compared with the internationally recommended reference levels (U.S Environmental Protection Agency limit 11.1 Bq/l), there were no indications of existence of radon problems in the water sources in this survey. Therefore the drinking water in Erbil governorate is safe as far as radon concentration is concerned. (author)

  17. An analysis of factors affecting the high radon concentration in different types of houses

    Directory of Open Access Journals (Sweden)

    Gulan Ljiljana

    2017-01-01

    Full Text Available This paper presents an analysis of indoor radon measurements carried out in municipality of Zubin Potok, northwestern part of Kosovo and Metohija. Annual measurements in two rooms of each house were performed by solid state nuclear track detectors commercially known as Gammadata. Average indoor radon concentration in different type of houses varied from 29-326 Bq/m3. A different year of house's construction including various types of building materials were selected for survey. A detail analysis showed that the differences in radon concentration occur between various building materials used for construction, flooring level, type of room and behavior of inhabitants. It was found that building materials in some houses contribute additionally to indoor radon.

  18. Measurements of Indoor Radon Concentrations in Chaiya and Tha Chana Districts, Surat Thani Province, Thailand

    International Nuclear Information System (INIS)

    Titipornpun, K.; Titipornpun, A.; Sola, P.; Bhongsuwan, T.

    2014-01-01

    Chaiya and Tha Chana districts of Surat Thani province are located in the areas with high equivalent uranium at ground surface, which have been identified as sources of radon. A survey measurement of indoor radon concentrations was carried out in 248 houses, using CR-39 detectors in closed cups. All of the detectors were exposed to radon for forty days. After the exposure, the alpha tracks were made visible by chemical etching and counted manually under an optical microscope. The indoor concentrations in Chaiya district were found to vary from the minimum to the maximum of 4 Bq.m -3 to 88 Bq.m -3 , respectively. In Tha Chana district, the concentrations of indoor radon were varied from the minimum of 4 Bq.m -3 to the maximum of 159 Bq.m -3 . The geometric mean of indoor radon concentrations in Chaya and Tha Chana districts were found to be 26±2 Bq.m -3 and 30±2 Bq.m -3 , respectively. The overall geometric mean in the surveyed areas was 28±2 Bq.m -3 . Only in two houses (1%), the concentrations (151 and 159 Bq.m -3 ) were found to be higher than the action level recommended by the US EPA (148 Bq.m -3 ). Most houses (94%) have natural ventilation by keeping doors and windows opened during the daytime. This ventilation likely causes the low level of indoor radon concentrations.

  19. Plate-out rates of radon progeny and particles in a spherical chamber

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Chen, B.T.

    1990-01-01

    In indoor and mining environments, deposition or ''plate-out'' of radon progeny onto walls occurs simultaneously with attachment of the radon progeny to airborne particles. Attachment and plate-out processes affect the atmosphere in which radon exposures takes place by reducing concentrations and shifting activity size distributions. Both processes have important consequences in determining the deposition pattern and initial dose of inhaled radon progeny. Theoretical deposition models show that turbulence and natural convection in a room are the major factors that influence plate-out rates. Here we describe plate-out measurements for radon progeny and aerosol particles in a spherical chamber under controlled laboratory conditions. The temperature and velocity profiles in still and turbulent air were monitored. A 161-liter spherical aluminum chamber was used to study the mixing. During mixing, air velocity was detected when rotational speeds were higher than 500 rpm. Monodisperse silver aerosols and polystyrene latex particles in the size range of 5 nm to 2 μm were used in the deposition study. Radon-220 progeny were generated by passing Rn-220 gas into the chamber and letting the gas decay into 212 Pb. The deposition rates of the particles and radon progeny ( 212 Pb) in the chamber were determined by monitoring the concentration decay of the aerosol as a function of time

  20. Temporal variability of atmospheric radon-222 concentration at Gosan Station, Jeju Island, Korea, during 2009-2013

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jung Min; Kim, Won Hyung; Kang, Chang Hee [Dept. of Chemistry, Jeju National University, Jeju (Korea, Republic of); Lee, Hae Young; Lee, Chul Kyu [Korea Global Atmosphere Watch Center, Korea Meteorological Administration, ChungNam (Korea, Republic of); Chambers, S.; Williams, A. G. [Australian Nuclear Science and Technology Organisation, Kirrawee DC (Australia)

    2015-02-15

    Atmospheric radon-222 (radon) measurements were made from 2009 to 2013 at the Gosan station of Jeju Island, one of the cleanest regions in Korea, in order to characterize the temporal variability (on diurnal, seasonal, and annual scales) and analyze the influence of changing air mass transport pathways on observed radon concentrations. The mean hourly radon concentration over the whole period was 2441 ± 1037 mBq/m{sup 3}. The seasonal cycle of radon at the Gosan station was characterized by a fall maximum and summer minimum, consistent with a reduction in nonfrozen terrestrial fetch from fall to summer. In order, the seasonal mean radon concentrations were 2962 mBq/m{sup 3} (fall) >2907 mBq/m{sup 3} (winter) >2219 mBq/m{sup 3} (spring) >1756 mBq/m{sup 3} (summer). Based on a 5-year composite, the maximum mean monthly radon concentration in October (3100 mBq/m{sup 3}) was more than twice the July minimum (1471 mBq/m{sup 3}). Diurnal composite radon concentrations for the whole period increased throughout the night to a maximum of 2788 mBq/m{sup 3} at around 7 a.m., and then gradually decreased to a minimum of 2050 mBq/m{sup 3} at around 3 p.m. The winter diurnal cycle had a small amplitude due to the low variability in atmospheric mixing depth associated with recent air mass fetch over the Yellow Sea. The diurnal cycle in summer, however, exhibited a relatively large amplitude due to changes in atmospheric mixing depth associated with recent fetch over Jeju Island. Back trajectory analysis showed that high radon events were typically associated with long-term air mass fetch over continental Asia. Specifically, the average radon concentration of air masses originating from China was about 2.4 times higher than that of air masses originating from the North Pacific Ocean.

  1. Temporal variability of atmospheric radon-222 concentration at Gosan Station, Jeju Island, Korea, during 2009-2013

    International Nuclear Information System (INIS)

    Song, Jung Min; Kim, Won Hyung; Kang, Chang Hee; Lee, Hae Young; Lee, Chul Kyu; Chambers, S.; Williams, A. G.

    2015-01-01

    Atmospheric radon-222 (radon) measurements were made from 2009 to 2013 at the Gosan station of Jeju Island, one of the cleanest regions in Korea, in order to characterize the temporal variability (on diurnal, seasonal, and annual scales) and analyze the influence of changing air mass transport pathways on observed radon concentrations. The mean hourly radon concentration over the whole period was 2441 ± 1037 mBq/m"3. The seasonal cycle of radon at the Gosan station was characterized by a fall maximum and summer minimum, consistent with a reduction in nonfrozen terrestrial fetch from fall to summer. In order, the seasonal mean radon concentrations were 2962 mBq/m"3 (fall) >2907 mBq/m"3 (winter) >2219 mBq/m"3 (spring) >1756 mBq/m"3 (summer). Based on a 5-year composite, the maximum mean monthly radon concentration in October (3100 mBq/m"3) was more than twice the July minimum (1471 mBq/m"3). Diurnal composite radon concentrations for the whole period increased throughout the night to a maximum of 2788 mBq/m"3 at around 7 a.m., and then gradually decreased to a minimum of 2050 mBq/m"3 at around 3 p.m. The winter diurnal cycle had a small amplitude due to the low variability in atmospheric mixing depth associated with recent air mass fetch over the Yellow Sea. The diurnal cycle in summer, however, exhibited a relatively large amplitude due to changes in atmospheric mixing depth associated with recent fetch over Jeju Island. Back trajectory analysis showed that high radon events were typically associated with long-term air mass fetch over continental Asia. Specifically, the average radon concentration of air masses originating from China was about 2.4 times higher than that of air masses originating from the North Pacific Ocean

  2. Radon concentration inversions in the troposphere

    International Nuclear Information System (INIS)

    Pereira, E.B.

    1987-07-01

    Vertical concentrations of radon in the lower troposphere were obtained in Southern Brazil up to 7Km high and have shown unexpected inverted profiles. The presence of low pressure center systems southwest to the flight path suggested that inversions might have been originated by a vertical transport mechanism based on the large scale circulation of developing synoptic systems. A simple friction-driven circulation model was contructed and the transport equation was solved. (author) [pt

  3. Determination of the concentration of {alpha} emitting radioactive aerosols; Mesure de la concentration des aerosols radioactifs emetteurs {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-06-15

    In the first part of this work the techniques used for the quantitative measurement of the concentrations of aerosols carrying short lived (radon or thoron daughters) or long lived (uranium) {alpha} radioactive emitters are described. In the second part the author investigates the problem of the determination of radon concentration in air by means of activity determinations on airborne dusts. Special reference is made to the measurement of the radon active deposit on two types of dusts (iron oxide (yellow) and uranium oxide) in small chambers (6 liters). In the third part are given data resulting from determinations of radon and thoron concentrations in atmospheric air in the south of Paris area using this method. (author) [French] Dans la premiere partie de ce travail on expose les techniques utilisees pour la mesure quantitative des concentrations d'aerosols contenant des emetteurs radioactifs {alpha}, tant pour ceux a vie courte (derives du radon ou du thoron) que pour ceux a vie longue (uranium). Dans la seconde partie on traite le probleme de la determination de la concentration de l'air en radon par la mesure de l'activite des poussieres ayant sejourne dans cet air. En particulier, on indique pour de petits volumes (6 litres) la proportion de depot actif du radon qui est fixee sur deux types de poussieres (limonite et oxyde d'uranium) en fonction de la concentration de celles-ci. Dans la troisieme partie on donne quelques exemples de mesure par cette methode de la concentration en radon et en thoron de l'atmosphere de la region parisienne. (auteur)

  4. Soil radon concentration and volcanic activity of Mt. Etna before and after the 2002 eruption

    International Nuclear Information System (INIS)

    Imme, G.; La Delfa, S.; Lo Nigro, S.; Morelli, D.; Patane, G.

    2006-01-01

    Soil radon investigation, using a continuous measurement device, has been performed on Mt. Etna in order to observe possible anomalies due to seismic and/or volcanic activity. In October 2002 an eruptive event occurred. Measurements, performed on the NE flank, have shown a possible correlation between eruptive activity of the volcano and soil radon concentration anomaly. The study of the seismic activity recorded in the same flank has, also, allowed to characterize the volcano dynamics and to correlate it with the variations of radon. The obtained results seem to indicate a possible dependence on volcanic activity of the radon concentration

  5. Radon concentrations in residential housing in Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Yonehara, Hidenori; Aoyama, Takashi; Radford, E.P.; Kato, Hiroo; Sakanoue, Masanobu.

    1992-01-01

    A measurement of indoor radon ( 222 Rn) concentrations in Hiroshima and Nagasaki was carried out to examine an effect of the exposure on atomic bomb (A-bomb) survivors. Two hundred dwellings (100 from each city), chiefly of members of the Life Span Study population which is a fixed cohort studied by Radiation Effects Research Foundation (RERF), were selected for this survey. We used two types of alpha-track detector: a Terradex detector type SF and a bare-track detector improved by Yonehara et al. Comparative measurements showed that although there was an adequate correlation between the values obtained using the two detectors, the geometric mean value for the bare-track detector was 45% of that for the Terradex detector. This difference was considered to be due to differences in the calibration methods and sensitivities of the detectors to thoron ( 220 Rn). The arithmetic mean values of the radon concentrations for 193 locations in Hiroshima and 192 locations in Nagasaki measured by Terradex SF detector were 103 Bq m -3 and 40.6 Bq m -3 , respectively. The values at 100 locations in Hiroshima and at 93 locations in Nagasaki measured by the bare detector were 43.1. Bq m -3 and 13.6 Bq m -3 , respectively. The significant difference between the geometric mean values of the concentration in Hiroshima and Nagasaki measured by both methods was observed. The difference might be attributable to the different geological environments of the two cities. The difference between the estimated dose equivalents for exposure to radon daughters in dwellings in Hiroshima and Nagasaki over the last 30 years might amount to 0.4 or 0.8 Sv; however, no statistically significant difference was observed in lung cancer mortality in the low-dose range in either city. Nevertheless, the indoor-radon concentrations estimated in this survey could significantly influence the dose-response relationships for A-bomb exposure. (author)

  6. Influence of shallow mine-workings on the radon concentrations in houses: a problem of old mining regions

    International Nuclear Information System (INIS)

    Lehmann, R.; Czarwinski, R.

    1994-01-01

    In some regions of the German New Federal Lands, residues from early mining characterise the radiological situation and can also influence the radon concentration in buildings. Construction on waste rock with increased radium concentration, the use of waste rock as building material and construction above shallow mine shafts and adits are important in this connection. In Saxony, for instance, one has to reckon with probably hundreds of buildings that may be influenced by radon from shallow mine workings. Very short-term changes of radon concentrations in buildings over several orders of magnitude as well as their close temporal correlation with the underground airflow clearly indicate influences from underground. In Schneeberg and Schlema, fluctuations of radon concentration in buildings of several 10,000 Bq.m -3 within one hour were observed. In Schneeberg, the old mine was ventilated artificially by installing a ventilator with an output volume of 500 m 3 .min -1 . Thus the radon concentration in buildings of the central city area has been reduced. In Schlema, the radon-rich shafts of early mining are ventilated at present by the still active ventilation system of the suspended uranium ore mining. In 1992, during the first 4.5 x 10 9 m 3 of mine air with a radon activity of 6.3 x 10 14 Bq were extracted from the mine. If the mine ventilators are switched off, radon concentration in buildings over mine shaft increases sharply by two orders of magnitude. (author)

  7. Time-scale invariant changes in atmospheric radon concentration and crustal strain prior to a large earthquake

    Directory of Open Access Journals (Sweden)

    Y. Kawada

    2007-01-01

    Full Text Available Prior to large earthquakes (e.g. 1995 Kobe earthquake, Japan, an increase in the atmospheric radon concentration is observed, and this increase in the rate follows a power-law of the time-to-earthquake (time-to-failure. This phenomenon corresponds to the increase in the radon migration in crust and the exhalation into atmosphere. An irreversible thermodynamic model including time-scale invariance clarifies that the increases in the pressure of the advecting radon and permeability (hydraulic conductivity in the crustal rocks are caused by the temporal changes in the power-law of the crustal strain (or cumulative Benioff strain, which is associated with damage evolution such as microcracking or changing porosity. As the result, the radon flux and the atmospheric radon concentration can show a temporal power-law increase. The concentration of atmospheric radon can be used as a proxy for the seismic precursory processes associated with crustal dynamics.

  8. PO.RA project. An analysis on gas radon concentrations in soil versus fluctuations in the groundwater table

    International Nuclear Information System (INIS)

    Serentha', C.; Torretta, M.

    2001-01-01

    Man is daily exposed to natural radiation, mainly due to cosmic rays and natural radioactive elements, whose most important radioactive daughters are 222 Rn (radon) and 220 Rn (thoron). Being these ones gaseous, they can spread through the ground, reaching the atmosphere and accumulating in rooms, where their concentrations may be very high. As radon exhalation is strongly connected with the hydrogeological features of the environment, this study tried to find a relationship between fluctuations in the groundwater table and gas radon concentrations in soil, in order to try estimates of indoor radon concentrations [it

  9. Geographical distribution of the annual mean radon concentrations in primary schools of Southern Serbia – application of geostatistical methods

    International Nuclear Information System (INIS)

    Bossew, P.; Žunić, Z.S.; Stojanovska, Z.; Tollefsen, T.; Carpentieri, C.; Veselinović, N.; Komatina, S.; Vaupotič, J.; Simović, R.D.; Antignani, S.; Bochicchio, F.

    2014-01-01

    Between 2008 and 2011 a survey of radon ( 222 Rn) was performed in schools of several districts of Southern Serbia. Some results have been published previously (Žunić et al., 2010; Carpentieri et al., 2011; Žunić et al., 2013). This article concentrates on the geographical distribution of the measured Rn concentrations. Applying geostatistical methods we generate “school radon maps” of expected concentrations and of estimated probabilities that a concentration threshold is exceeded. The resulting maps show a clearly structured spatial pattern which appears related to the geological background. In particular in areas with vulcanite and granitoid rocks, elevated radon (Rn) concentrations can be expected. The “school radon map” can therefore be considered as proxy to a map of the geogenic radon potential, and allows identification of radon-prone areas, i.e. areas in which higher Rn radon concentrations can be expected for natural reasons. It must be stressed that the “radon hazard”, or potential risk, estimated this way, has to be distinguished from the actual radon risk, which is a function of exposure. This in turn may require (depending on the target variable which is supposed to measure risk) considering demographic and sociological reality, i.e. population density, distribution of building styles and living habits. -- Highlights: • A map of Rn concentrations in primary schools of Southern Serbia. • Application of geostatistical methods. • Correlation with geology found. • Can serve as proxy to identify radon prone areas

  10. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  11. Evaluation of radon concentration in dwellings and well water of Parana State-Brazil

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi

    2011-01-01

    Considering the growing interest of International Agencies and national Governmental organs in studies and measurements of radon activity in air, soil gas and ground water (mainly from artesian wells) as well as scarceness of such measurements at Brazilian territory, present studies were initiated by the Laboratory of Applied Nuclear Physics of Federal University of Technology - Parana (UTFPR) in collaboration with the Institute of Radiation Protection and Dosimetry (IRD) and the Center of Nuclear Technology Development (CDTN) of Brazilian Commission on Nuclear Energy (CNEN). This Collaboration started in 2003. Radon monitoring program is based mainly on use of Solid State Nuclear Track Detectors for radon activity measurements in air. Continuous electronic radon detectors are used for radon measurements in soil gas and water. Current work presents the results of indoor 222 Rn activity of dwellings and working places of Curitiba-PR and radon concentration in ground water samples from artesian wells from aquifers of the same area. The indoor measurements of radon activity were performed using Solid State Nuclear Track Detectors CR-39. After the exposition, CR-39 detectors were submitted to chemical development which permitted to make alpha particle tracks counting. The results of calibration of CR-39 together with efficiency of used exhalation chambers as well as alpha particle tracks chemical development procedure were performed in cooperation with CDTN and collaboration with the National Institute of Radiological Sciences (NIRS). The major part of indoor 222 Rn concentration in residences was found below 100 Bq/m3. In the case of working places, all measurements present 222 Rn concentration bellow 100 Bq/m3. The studies of radon activity in water were performed using the samples of water from artesian wells submitted to recursive measurements by instant radon detector AlphaGUARD PQ2000 PRO during few weeks with intervals of about 4 days between each measurement

  12. Airborne concentrations of radioactive materials in severe accidents

    International Nuclear Information System (INIS)

    Ross, D.F. Jr.; Denning, R.S.

    1989-01-01

    Radioactive materials would be released to the containment building of a commercial nuclear reactor during each of the stages of a severe accident. Results of analyses of two accident sequences are used to illustrate the magnitudes of these sources of radioactive materials, the resulting airborne mass concentrations, the characteristics of the airborne aerosols, the potential for vapor forms of radioactive materials, the effectiveness of engineered safety features in reducing airborne concentrations, and the release of radioactive materials to the environment. Ability to predict transport and deposition of radioactive materials is important to assessing the performance of containment safety features in severe accidents and in the development of accident management procedures to reduce the consequences of severe accidents

  13. Indoor air radon concentration in schools in Prizren, Kosovo

    International Nuclear Information System (INIS)

    Bahtijari, M.; Stegnar, P.; Shemsidini, Z.; Kobal, I.; Vaupotic, J.

    2006-01-01

    Indoor air radon ( 222 Rn) concentrations were measured in spring and winter in 30 rooms of 9 elementary schools and 19 rooms of 6 high schools in Prizren, Kosovo, using alpha scintillation cells. Only in three rooms of elementary schools and four rooms of high schools did winter concentrations exceed 400 Bq m -3 . (authors)

  14. Radon concentrations in ground and drinking water in the state of Chihuahua, Mexico

    International Nuclear Information System (INIS)

    Villalba, L.; Colmenero Sujo, L.; Montero Cabrera, M.E.; Cano Jimenez, A.; Renteria Villalobos, M.; Delgado Mendoza, C.J.; Jurado Tenorio, L.A.; Davila Rangel, I.; Herrera Peraza, E.F.

    2005-01-01

    This paper reports 222 Rn concentrations in ground and drinking water of nine cities of Chihuahua State, Mexico. Fifty percent of the 114 sampled wells exhibited 222 Rn concentrations exceeding 11 Bq/L, the maximum contaminant level (MCL) recommended by the USEPA. Furthermore, around 48% (123 samples) of the tap-water samples taken from 255 dwellings showed radon concentrations over the MCL. There is an apparent correlation between total dissolved solids and radon concentration in ground-water. The high levels of 222 Rn found may be entirely attributed to the nature of aquifer rocks

  15. Radon concentrations in ground and drinking water in the state of Chihuahua, Mexico.

    Science.gov (United States)

    Villalba, L; Colmenero Sujo, L; Montero Cabrera, M E; Cano Jiménez, A; Rentería Villalobos, M; Delgado Mendoza, C J; Jurado Tenorio, L A; Dávila Rangel, I; Herrera Peraza, E F

    2005-01-01

    This paper reports (222)Rn concentrations in ground and drinking water of nine cities of Chihuahua State, Mexico. Fifty percent of the 114 sampled wells exhibited (222)Rn concentrations exceeding 11Bq/L, the maximum contaminant level (MCL) recommended by the USEPA. Furthermore, around 48% (123 samples) of the tap-water samples taken from 255 dwellings showed radon concentrations over the MCL. There is an apparent correlation between total dissolved solids and radon concentration in ground-water. The high levels of (222)Rn found may be entirely attributed to the nature of aquifer rocks.

  16. Control in indoor radon decay products by air treatment devices

    International Nuclear Information System (INIS)

    Hinds, W.C.; Rudnick, S.N.; Maher, E.F.; First, M.W.

    1983-01-01

    An evaluation of the efficacy of household air cleaning devices as a means to control radon decay products in existing buildings is presented. Previous research on air cleaning methods for airborne radon decay products has been directed primarily to the control of radon decay products in mines and has only limited application to control in residences where dust concentration, air change rate, and humidity are lower than in mines. Results show that room size air cleaners can achieve substantial reductions in working levels in residences. Reductions observed at air infiltration rates of 0.52 air changes per hour ranged from 58 to 89%. Although the two air cleaners tested produced the greatest reductions, the low cost, simplicity, and other benefits of air circulating fans, particularly the ceiling fan, appear to make them most suitable for residences

  17. Investigation of the relationship between earthquakes and indoor radon concentrations at a building in Gyeongju, Korea

    Directory of Open Access Journals (Sweden)

    Jae Wook Kim

    2018-04-01

    Full Text Available This article measured and analyzed the indoor radon concentrations at one university building in Gyeongju, Republic of Korea, to investigate if there is any relationship between earthquakes and indoor radon concentration. Since 12 September 2016, when two 5.1 and 5.8 magnitude earthquakes occurred, hundreds of aftershocks affected Gyeongju until January 2017. The measurements were made at the ground floor of the Energy Engineering Hall of Dongguk University in Gyeongju over a period between February 2016 and January 2017. The measurements were made with an RAD7 detector on the basis of the US Environmental Protection Agency measurement protocol. Each measurement was continuously made every 30 minutes over the measurement period every month. Among earthquakes with 2.0 or greater magnitude, the earthquakes whose occurrence timings fell into the measurement periods were screened for further analysis. We observed similar spike-like patterns between the indoor radon concentration distributions and earthquakes: a sudden increase in the peak indoor radon concentration 1–4 days before an earthquake, gradual decrease before the earthquake, and sudden drop on the day of the earthquake if the interval between successive earthquakes was moderately longer, for example, 3 days in this article. Keywords: Earthquakes, Gyeongju, Indoor Radon Concentration, RAD7, Radon Anomaly

  18. Determination of radon concentration in drinking water resources of villages nearby Lalehzar fault and evaluation the annual effective dose

    International Nuclear Information System (INIS)

    Mohammad Malakootian; Zahra Darabi Fard; Mojtaba Rahimi

    2015-01-01

    The radon concentration has been measured in 44 drinking water resources, in villages nearby Lalehzar fault in winter 2014. Some samples showed a higher concentration of radon surpassing limit set by EPA. Further, a sample was taken from water distribution networks for these sources of water. Soluble radon concentration was measured by RAD7 device. Range radon concentration was 26.88 and 0.74 BqL -1 respectively. The maximum and minimum annual effective dose for adults was estimated at 52.7 and 2.29 µSvY -1 , respectively. Reducing radon from water before use is recommended to improve public health. (author)

  19. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  20. Diagnostics of and measures against radon concentrations in a dwelling

    International Nuclear Information System (INIS)

    Berger, H.

    1994-02-01

    Results are presented of measurements in a test-dwelling in the period april 1993 - november 1993. The purpose of the measurements was to investigate the possibilities of using a blower door (a fan in a wall of the dwelling) for specifying sources of radon in the dwelling, employing the diagnostic method developed at the KVI (Nuclear Physics Accelerator Institute in Groningen, Netherlands). Special attention is paid to the measurement of two input variables for the diagnostic method: transparency of the walls of the dwelling and the strength of static sources. Also measures aimed at reducing radon concentrations in the dwelling are discussed. The main conclusions are that (a) the pressure-variation method is a valid procedure to measure the transparency of walls and floors; (b) the blower door is a suitable technique for arriving at a correct diagnosis; and (c) over-pressurizing the crawl-space is the most effective measure in reducing the radon concentration of the crawl-space. More research on air flows in the soil is recommended. 21 figs., 28 tabs., 7 refs

  1. Influence of energy-saving measures on the radon concentration in some kindergartens in the Czech Republic

    International Nuclear Information System (INIS)

    Fojtikova, I.; Navratilova Rovenska, K.

    2014-01-01

    Due to the large number of subsidies for energy-saving reconstructions granted, and expecting a strong influence of reconstruction on the radon level in building, the long-term measurements of radon concentration are offered free of charge to kindergartens in the Czech Republic. Classrooms and playrooms where the radon levels exceeded the reference value for kindergartens, which is 400 Bq m -3 , are monitored continuously for at least a week to obtain the average activity concentration of radon when children are present. Some of the kindergartens were previously measured in the 1990's. These earlier measurements have provided an opportunity to compare the results. This paper presents some lessons learned from radon diagnosis carried out in particular cases and an analysis of the influence of reconstruction work on the radon level in the buildings. (authors)

  2. Concentration of Radon, thoron and their progeny levels in different types of floorings, walls, rooms and building materials

    International Nuclear Information System (INIS)

    Sathish, L. A.; Nagaraja, K.; Ramanna, H. C.; Nagesh, V.; Sundareshan, S.

    2009-01-01

    Radon, thoron and their progenies are the most important contributions to human exposure from natural sources. Radon exists in soil gas, building materials, Indoor atmosphere etc. Among all the natural sources of radiation dose to human beings, inhalation of radon contributes a lot. The work presented here emphasizes the long term measurements of radon, thoron and their progeny concentrations in about 100 dwellings using solid state nuclear track detectors. Materials and Methods: Measurements were made using dosimeters and the concentrations were estimated by knowing the track density of films through spark counter, and sensitivity factor for bare, filter and membrane films. Results: Presence of radon and thoron in houses is the effect of several aspects such as the activity concentrations of uranium, radium and thorium in the local soil, building materials, ventilation of houses and also entry of radon into houses through the cracks in floor/wall. Conclusion: The observations reveal that the concentrations of radon and/or thoron are relatively higher in granite than in concrete, cement and bricks. In continuation to this the concentration observed in bathrooms is more compared to kitchen bedroom and living rooms. This study discloses that the residential rooms of good ventilation will avoid the health hazards due to radon and its rich materials.

  3. New three-count technique for short-lived radon decay products in air

    International Nuclear Information System (INIS)

    Tian Deyuan; Lu Zhizhao

    1998-01-01

    Up to the present, radon and its short-lived decay products in air are usually monitored by means of a detection. But radon progeny, including RaB ( 214 Pb) and RaC ( 214 Bi) which are β and γ emitters, contribute about 90% to the equilibrium equivalent radon concentration (EECRn). Therefore, this paper introduces a new three-count technique by a β detector in the light of radioactive decay law and its boundary conditions during sampling and counting times to solve the Bateman equation. β (even low level β) instruments have been fairly popularized domestically and internationally. It can be used not only as an instrument for radon and its daughters in air, but also as a monitor for β airborne activity in the environment. This new method taps further the latent power of the present instrument and realizes various uses for a unit. (author)

  4. Radon Concentration in Outdoors and Indoors Around the Flare in Oil Mine Sites; Konsentrasi Gas Radon di Udara di Luar dan Dalam Rumah Sekitar Nyala-api Kawasan Tambang Minyak

    Energy Technology Data Exchange (ETDEWEB)

    Sutarman,; Wahyudi, [Centre for Research and Development of Radiation Safety and Nuclear Biomedicine, National Nuclear Energy Agency, Jakarta (Indonesia); Luhantara, [University of Indonesia, Jakarta (Indonesia)

    2003-03-15

    The flares are much found at the oil exploration areas which appear the combustion gases emission to the environment that pass through a pipe at about 8 m high from the ground level. The flare is released into the environment together with the hydrocarbon and radon gases. This study has been carried out the measurement of the radon gas concentration only. Radon is a radioactive gas which comes from the natural radioactive decay of uranium ({sup 238}U). The outdoor radon concentrations were measured in 23 locations with the two-filter method. The locations were determined by a circle which the flare as the point center. The outdoor radon concentrations were measured in 74 houses (more than distance of 600 m from the flare) with the alpha track detector (CR-39) placed in the living rooms for about three months. The measurements of the radon concentrations were carried out in Cepu, Cirebon, and Prabumulih oil mine sites. The results showed that the outdoor radon concentrations a range of 108 Bq/m{sup 3} to 256 Bq/m{sup 3} in Cepu, 248 Bq/m{sup 3} to 3525 Bq/m{sup 3} in Cirebon, and 51 Bq/m{sup 3} to 114 Bq/m{sup 3} in Prabumulih. The results showed that the indoor radon concentrations a range of 11 Bq/m{sup 3} to 38 Bq/m{sup 3} in Cepu, 28 Bq/m{sup 3} to 184 Bq/m{sup 3} in Cirebon, and 12 Bq/m{sup 3} to 38 Bq/m{sup 3} in Prabumulih. The data of the maximum radon concentration in outdoor air was higher than an actual level which recommended by International Atomic Energy Agency (IAEA) for workplaces. The maximum radon concentration in indoor air was lower than an actual level which recommended by IAEA for dwellings. IAEA recommends the actual level of 1000 Bq/m{sup 3} for workplaces and 200 Bq/m{sup 3} for dwellings. These data will be used for the baseline data of the environmental radioactivity in Indonesia. (author)

  5. Low air exchange rate causes high indoor radon concentration in energy-efficient buildings.

    Science.gov (United States)

    Vasilyev, A V; Yarmoshenko, I V; Zhukovsky, M V

    2015-06-01

    Since 1995, requirements on energy-efficient building construction were established in Russian Building Codes. In the course of time, utilisation of such technologies became prevailing, especially in multi-storey building construction. According to the results of radon survey in buildings constructed meeting new requirements on energy efficiency, radon concentration exceeds the average level in early-constructed buildings. Preponderance of the diffusion mechanism of radon entry in modern multi-storey buildings has been experimentally established. The experimental technique of the assessment of ventilation rate in dwellings under real conditions was developed. Based on estimates of average ventilation rate, it was approved that measures to increase energy efficiency lead to reduction in ventilation rate and accumulation of higher radon concentrations indoors. Obtained ventilation rate values have to be considered as extremely low. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist Route "Liczyrzepa" Mine in Kowary Adit

    Science.gov (United States)

    Wołoszczuk, Katarzyna; Skubacz, Krystian

    2018-01-01

    Central Laboratory for Radiological Protection, in cooperation with Central Mining Institute performed measurements of radon concentration in air, potential alpha energy concentration (PAEC), particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist-Educational Route "Liczyrzepa" Mine in Kowary Adit. A research study was developed to investigate the appropriate dose conversion factors for short-lived radon progeny. The particle size distribution of radon progeny was determined using Radon Progeny Particle Size Spectrometer (RPPSS). The device allows to receive the distribution of PAEC in the particle size range from 0.6 nm to 2494 nm, based on their activity measured on 8 stages composed of impaction plates or diffusion screens. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometres to about 20 micrometres using Aerodynamic Particle Sizer (APS) spectrometer and the Scanning Mobility Particle Sizer Spectrometer (SMPS).

  7. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Experience in mines shows that a very high concentration of radon daughters builds up in an unventilated dead end heading. Even minimal air movement results in a drastic reduction in radon daughter concentration. Designing the ventilation system to provide an optimized flow of fresh air into the workplace results in acceptable climatic conditions and radon daughter levels. The example of the Director fluorospar mine in Newfoundland is used to illustrate the actual design and operation of a ventilation system that provided effective radon daughter control. It was found at this mine that the age of the air underground should be kept as low as possible; that no areas of the mine should be left unventilated unless they could be kept at negative pressure; that a comparatively simple remote control and monitoring system helped stabilize ventilation and detected upsets; that the ventilation system should operate continuously, even when the mine is shut down for short periods; and that pressurization of the mine seemed to inhibit radon influx

  8. Measurements of indoor radon concentration in italian red cross workplaces: preliminary results

    International Nuclear Information System (INIS)

    Fontana, C.; Musumeci, R.G.; Valeriani, F.; Tonnarini, S.; Trevisi, R.

    2002-01-01

    In August 2000 in Italy the D.Lgs.241/00 law was passed to implement the 96/29 Euratom Directive (BSS Directive, EC 1996). D.Lgs.241/00 states that workers cannot be exposed to decay products of radon, thoron and gamma radiation at a level higher than action level. The law became effective January 1, 2001. Italian action level of 500 Bq/m3 is the annual average indoor radon concentration. Work activities in zones with greater probability of high indoor radon concentration have to be identified. According to the law, a Commission must establish criteria for clarifying areas at risk. The actual work of classification is then done by the regions. A three year time period was given to define areas at risk. As the normative still must be completed, the Italian Red Cross and the Italian National Institute for Occupational Prevention and Safety initiated this study both because the Red Cross has always been sensitive to health problems and also to offer the Commission further experimental data regarding radon in Italy

  9. Effectiveness of finish materials and room air-conditioner on the reduction of indoor radon concentration in Hong Kong

    International Nuclear Information System (INIS)

    Ma, A.K.; Man, C.K.; Ho, E.; Pang, S.W.

    1995-01-01

    Four different kinds of finish material were investigated: wallpaper, paint, plaster and tile. When applied to the bare concrete walls of uninhabited rooms in flats of a building under construction, all of them were found to reduce indoor radon concentration. The magnitude of reduction by these finish materials ranged from 20% to 80%. Wallpaper was found to provide the best protection against radon emission from bare concrete walls in a bedroom with a size of 19.3 m 3 . Wallpaper can reduce the indoor radon concentration about twice as much as paint (water-based) or plaster in this investigation. Tile was also found to be a good material against radon emission from concrete walls in a bathroom with a size of 6.3 m 3 . Indoor radon concentration was found to decrease with elevation from the ground level, and was affected strongly by mechanical ventilation. Another 30% to 50% reduction in indoor radon concentration in addition to finish material can be achieved by a room air-conditioner. It was also found that indoor radon concentrations were not affected by turning the fresh air shutter to the 'on' or 'off' position in the room air-conditioner. (author)

  10. E-perm radon monitors for determining waterborne concentrations of dissolved in radon 222Rn

    International Nuclear Information System (INIS)

    Jester, W.A.; Kotrappa, P.

    1989-01-01

    This paper describes a simple and relatively inexpensive method in which E-Perm radon monitors are used to determine the concentration of dissolved 222 Rn in drinking water. This procedure takes advantage of E-Perm's ability to accurately measure the integral radon exposure under conditions of high humidity. The method was evaluated against the liquid scintillation procedure recommended by the U.S. Environmental Protection Agency (EPA) and was found to give excellent agreement. An E-perm is an electret ion chamber that consists of a small chamber constructed from a conducting plastic and having an electret at its base and a filtered air inlet at the top. The technique described in this paper takes advantages of E-Perm's insensitivity to high humidity

  11. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    Directory of Open Access Journals (Sweden)

    Sudhir Mittal

    2016-04-01

    Full Text Available In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l−1 with the mean value of 4.42 Bq l−1, which lies within the safe limit from 4 to 40 Bq l−1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008. The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60.06 μSV y−1 with the mean value of 12.08 μSV y−1, which is lower than the safe limit 0.1 mSv y−1 as set by World Health Organization (WHO, 2004 and European Council (EU, 1998. Radon measurement in soil samples varies from 941 to 10,050 Bq m−3 with the mean value of 4561 Bq m−3, which lies within the range reported by other investigators. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard.

  12. Radon Concentration And Dose Assessment In Well Water Samples From Karbala Governorate Of Iraq

    Science.gov (United States)

    Al-Alawy, I. T.; Hasan, A. A.

    2018-05-01

    There are numerous studies around the world about radon concentrations and their risks to the health of human beings. One of the most important social characteristics is the use of water wells for irrigation, which is a major source of water pollution with radon gas. In the present study, six well water samples have been collected from different locations in Karbala governorate to investigate radon concentration level using CR-39 technique. The maximum value 4.112±2.0Bq/L was in Al-Hurr (Al-Qarih Al-Easariah) region, and the lowest concentration of radon was in Hay Ramadan region which is 2.156±1.4Bq/L, with an average value 2.84±1.65Bq/L. The highest result of annual effective dose (AED) was in Al-Hurr (Al-Qarih Al-Easariah) region which is equal to 15.00±3.9μSv/y, while the minimum was recorded in Hay Ramadan 7.86±2.8μSv/y, with an average value 10.35±3.1μSv/y. The current results have shown that the radon concentrations in well water samples are lower than the recommended limit 11.1Bq/L and the annual effective dose in these samples are lower than the permissible international limit 1mSv/y.

  13. Radon concentrations in ground and drinking water in the state of Chihuahua, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Villalba, L. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico); Colmenero Sujo, L. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico); Instituto Tecnologico de Chihuahua II, Ave. de las Industrias 11101, Chihuahua, Chih. (Mexico); Montero Cabrera, M.E. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico)]. E-mail: elena.montero@cimav.edu.mx; Cano Jimenez, A. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico); Renteria Villalobos, M. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico); Delgado Mendoza, C.J. [Facultad de Ciencias Quimicas, Universidad Autonoma de Chihuahua, Ciudad Universitaria S/N, Chihuahua, Chih. (Mexico); Jurado Tenorio, L.A. [Facultad de Ciencias Quimicas, Universidad Autonoma de Chihuahua, Ciudad Universitaria S/N, Chihuahua, Chih. (Mexico); Davila Rangel, I. [Centro Regional de Estudios Nucleares, Universidad Autonoma de Zacatecas, Cipres 20, Zacatecas, Zac. (Mexico); Herrera Peraza, E.F. [Centro de Investigacion en Materiales Avanzados, S.C., Miguel de Cervantes 120, Complejo Industrial Chihuahua, CP 31109 Chihuahua, Chih. (Mexico)

    2005-07-01

    This paper reports {sup 222}Rn concentrations in ground and drinking water of nine cities of Chihuahua State, Mexico. Fifty percent of the 114 sampled wells exhibited {sup 222}Rn concentrations exceeding 11 Bq/L, the maximum contaminant level (MCL) recommended by the USEPA. Furthermore, around 48% (123 samples) of the tap-water samples taken from 255 dwellings showed radon concentrations over the MCL. There is an apparent correlation between total dissolved solids and radon concentration in ground-water. The high levels of {sup 222}Rn found may be entirely attributed to the nature of aquifer rocks.

  14. Measuring variation of indoor radon concentration using bare nuclear tracks detectors, scintillation counters and surface barrier detectors

    International Nuclear Information System (INIS)

    Ishak, I.; Mahat, R.H.; Amin, Y.M.

    1996-01-01

    Bare LRI 15 nuclear track detectors , scintillators counter and surface barrier detectors were used to measured the indoor radon concentration in various location within two rooms. Spatial variation of the radon concentration is caused by positioning of the door, windows, furniture, cracks in the building and also distances from floor, wall and ceiling. It is found that the change in temperature are causing radon concentration to increase at certain time of the day

  15. Analysis of radon concentration in drinking water in Baoji (China) and the associated health effects

    International Nuclear Information System (INIS)

    Xinwei, L.

    2006-01-01

    This paper presents the results of radon concentration measurements in drinking water from the municipal water supply system and private wells located in Baoji (China)). The measurements were carried out on 69 samples. The mean values of tap water and well water were found to be 12 kBq m -3 with a maximum of 18 kBq m -3 and 41 kBq m -3 with a maximum of 127 kBq m -3 , respectively. The well water samples obtained from different depth-well (water-bearing levels), i.e. shallow well (well depth under 10 m) water, middle well (well depth 10-30 m) water and deep well water, have respective mean values of 24, 34 and 56 kBq m -3 . The contributions of the observed radon concentration in drinking water to indoor radon account for 2.8-13.2% of the mean value of Shaanxi indoor radon concentration and the effective dose to the dweller owing to inhalation of radon emanating from household water is 0.03-0.14 mSv y -1 . (authors)

  16. Airborne particulate concentrations and fluxes at an active uranium mill tailings site

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1978-01-01

    Direct measurements of airborne particulate concentrations and fluxes of transported mill tailing materials were measured at an active mill tailings site. Experimental measurement equipment consisted of meteorological instrumentation to automatically activate total particulate air samplers as a function of wind speed increments and direction, as well as particle cascade impactors to measure airborne respirable concentrations as a function of particle size. In addition, an inertial impaction device measured nonrespirable fluxes of airborne particles. Caclulated results are presented in terms of the airborne solid concentration in g/m 3 , the horizontal airborne mass flux in g/(m 2 -day) for total collected nonrespirable particles and the radionuclide concentrations in dpm/g as a function of particle diameter for respirable and nonrespirable particles

  17. [Experimental study on the influence of natural and artificial ventilation on indoor radon concentration].

    Science.gov (United States)

    Remetti, R; Gigante, G E

    2010-01-01

    The study presents the results of a campaign of measurements on the daily radon concentration using a Genitron Alpha Guard spectrometer. All the measurements have been intended to highlight the radon concentration variability during the 24 hours of the day and trying to find correlations with other ambient parameters such as temperature and pressure or local conditions such as the presence or not of a forced ventilation system. The main part of the measurements have been carried in the area of the Nuclear Measurement Laboratory of the Department of Basic and Applied Sciences for Engineering of "Sapienza" University of Rome. Results show a rapid rise of radon concentration in the night, when the artificial ventilation system was off and with door and windows closed. In the morning, after the opening of door and windows, the concentration falls down abruptly. With artificial ventilation system in function concentration never reaches significant values.

  18. An Alpha spectrometer for measuring radon daughter individual activity concentration

    International Nuclear Information System (INIS)

    Berico, M.; Formignani, M.; Mariotti, F.

    2001-01-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of 218 Po, 214 Pb and 214 Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated [it

  19. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  20. Measurement of radon, thoron and their progeny concentrations in the dwellings of Pauri Garhwal, Uttarakhand, India

    International Nuclear Information System (INIS)

    Joshi, Veena; Bijalwan, Pramesh; Rawat, Jasbir; Yadav, Manjulata; Ramola, R.C.; Mishra, Rosaline

    2015-01-01

    It is well known that inhalation of radon, thoron and their progeny contribute more than 50% of natural background radiation dose to human being. The time integrated passive measurements of radon, thoron and their progeny concentrations were carried out in the dwellings of Pauri Garhwal, Uttarakhand, India. The measurements of radon and thoron concentrations were performed by LR-115 detector based single entry Pin-Hole dosimeter while for the measurement of progeny concentrations, LR-115 deposition based DTPS/DRPS technique was used. The experimental techniques and results obtained are discussed in detail. (author)

  1. Radon levels in some dwellings around the international monument Taj Mahal, Agra using SSNTDs

    International Nuclear Information System (INIS)

    Kumar, Rupesh; Mahur, A.K.; Singh, H.; Sonkawade, R.G.; Swarup, R.

    2010-01-01

    The Taj Mahal, Agra had been on top priority of India and safe guarded by Taj Mahal Corridor. All the gaseous industrial discharges as well as fluid chemicals and water due to rain and river Yamuna toxic polluting entities had been taken into account while maintaining the beauty of Taj and purity of environment around it's rural areas. Indoor radon concentration depends in a complex way on the characteristic of the soil, the type of building structure, ventilation condition and occupant's behaviour. LR-115 Type II Solid State Nuclear Track Detectors (SSNTD's) have been used to measure the airborne radon levels in some dwellings near Taj Mahal, Agra. Radon concentrations were found to vary from 98 to 305 Bqm -3 with an average value of 213 Bqm -3 . Annual effective dose in these dwellings were found to vary from 1.3 to 4.4 mSv. (author)

  2. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  3. Influence of source type and air exchange on variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Winqvist, K.

    1986-04-01

    The model relates radon concentration to source strength and its variations, air exchange rate and meteorological factors. Two types of sources have been studied. The pressure difference dependent source is made up of radon transported with soil pore air and driven by pressure difference due to the stack effect. The constant source is made up of radon transported by diffusion from building materials or from soil. The air exchange rate depends exponentially on indoor-outdoor temperature difference and linearly on wind speed. These two inputs have been summed in quadrature. In a house with a constant source radon concentration decreases when the air exchange rate increases due to the increasing temperature difference, whereas the pressure difference dependent source causes an increasing concentration. This is due to the fact that the effect of the source strength increase is stronger than the decreasing effect of air exchange on concentration. The winter-summer concentration ratio depends on the combination of the two types of source. A pure pressure dependent source leads to the winter-summer ratio of 2-3.5 (winter -5 deg C, summer +15 deg C, wind speed 3 m/s). A strong contribution of a constant source is needed to cause a summer concentration higher than the winter concentration. The model is in agreement with the winter-summer concentration ratios measured. This ratio increases with the increasing winter concentration. The measured ratio was near 1.0 for houses with winter concentration of 200 Bq m''3 or less and near 2.0 with concentration of 1000 Bq m''3. In a house with a constant source, the diurnal maximum occurs in the afternoon, while in houses with a pressure difference dependent source the time of maximum is early in the morning

  4. Airborne Precursors Predict Maternal Serum Perfluoroalkyl Acid Concentrations.

    Science.gov (United States)

    Makey, Colleen M; Webster, Thomas F; Martin, Jonathan W; Shoeib, Mahiba; Harner, Tom; Dix-Cooper, Linda; Webster, Glenys M

    2017-07-05

    Human exposure to persistent perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctanesulfonate (PFOS), can occur directly from contaminated food, water, air, and dust. However, precursors to PFAAs (PreFAAs), such as dipolyfluoroalkyl phosphates (diPAPs), fluorotelomer alcohols (FTOHs), perfluorooctyl sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs), which can be biotransformed to PFAAs, may also be a source of exposure. PFAAs were analyzed in 50 maternal sera samples collected in 2007-2008 from participants in Vancouver, Canada, while PFAAs and PreFAAs were measured in matching samples of residential bedroom air collected by passive sampler and in sieved vacuum dust (<150 μm). Concentrations of PreFAAs were higher than for PFAAs in air and dust. Positive associations were discovered between airborne 10:2 FTOH and serum PFOA and PFNA and between airborne MeFOSE and serum PFOS. On average, serum PFOS concentrations were 2.3 ng/mL (95%CI: 0.40, 4.3) higher in participants with airborne MeFOSE concentrations in the highest tertile relative to the lowest tertile. Among all PFAAs, only PFNA in air and vacuum dust predicted serum PFNA. Results suggest that airborne PFAA precursors were a source of PFOA, PFNA, and PFOS exposure in this population.

  5. A comparison study between radon concentration in schools and other workplaces

    International Nuclear Information System (INIS)

    Clouvas, A.; Xanthos, S.

    2012-01-01

    The Nuclear Technology Laboratory of the Aristotle Univ. of Thessaloniki has since 1999 an open research project of indoor radon measurements in Greek workplaces. Since now 1380 measurements in 690 workplaces have been performed. Most (75 %) of the workplaces were offices in schools. The remaining 25 % were offices, mainly in public buildings. In the present study, a possible correlation between radon concentration in schools and other workplaces is investigated and discussed. (authors)

  6. Variation of radon concentration in soil with different depth along the high background areas in Kerala

    International Nuclear Information System (INIS)

    Sonia, S.R.; Visnu Prasad, A.K.; Jojo, P.J.; Midhun, M.

    2016-01-01

    Radon is one of the naturally occurring radioactive gases in the environment produced from decay of radium isotopes, which are the decay product of 238 U, 232 Th and 235 U. Hence the concentration of uranium and thorium in the bed rock and soil materials determine the amount of radon produced in the soil. The radon produced in the soil migrates through the mechanism of diffusion and convection through pore spaces in the soil, fractures in the rock and along with weak zones such as shear faults, thrust etc. For some geological situations, radon migrates long distances from its place of origin and can be detected by alpha-particle recorders at the earth's surface. Concentration of radon in an area is governed by the radium content in the minerals, radon emanating power in the material, permeability of the soils and underlying rock, and moisture content in the soil

  7. A study on surveillance of environmental factors affecting the variation of indoor radon concentration

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Shin Ae; Kim, Ok Ja; Lee, Mi Kyeong; Cho, Eun Ok; Choi, Yun Sun; Choi, Jin Kyeong; Park, Seon Hye; Han, Hyeon Sun [Hankook Research, Seoul (Korea, Republic of)

    2000-03-15

    Before the main survey, a preliminary survey was carried out to decide the most suitable type of a radon detector the most appropriate places to install such a radon detector. To this end, three types of detectors were set up in 108 locations, approximately 3% of 3,000 to measure the radon levels, and 102 detectors(94%) were collected. As a result of the preliminary survey, Radtrack was chosen as a radon detector for the main survey, and bedrooms on the first floor of houses and the first floor of public buildings were decided to be the places for the first installment of detectors. It is most desirable to survey the radon concentrations in all houses nationwide. Considering the survey period and budgets, however, 3,000 spots were targeted for the main survey at the recommendation of the Korea Institute of Nuclear Safety in charge of this study. As it is important to maintain the same panels for a year to measure the radon concentrations at 3,000 locations, a total of 3,237 panels, 10% more than the target sample number, were surveyed considering the possible loss of panels during the survey period. The first radon detector was installed in each of 3,237 spots in December 1999, and collected three months later in March 2000, followed by the installment of the second detector.

  8. A study of diurnal variations of radon and thoron concentrations in different indoor environmental conditions

    International Nuclear Information System (INIS)

    Pant, Preeti; Prasad, Mukesh; Ramola, R.C.

    2015-01-01

    The measurements for diurnal variations in radon ( 222 Rn) and thoron ( 220 Rn) concentrations were performed in the different indoor conditions of Tehri Garhwal, Uttarakhand, India by using AlphaGUARD, Portable Radon Monitor and RAD7. While selecting the dwellings, the ventilation conditions, building materials, life style of the inhabitants and their exposure time indoors were also considered. The behavior of indoor radon and thoron concentrations was observed for different type of dwellings with different environmental conditions. The measurement techniques, results obtained and comparison of the results are discussed in details. (author)

  9. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  10. Modeling the dependency of radon concentration levels inside ancient Egyptian tombs on the ambient temperature variations

    International Nuclear Information System (INIS)

    Metwally, S.M.; Abo-Elmagdb, M.; Salamaa, E.

    2007-01-01

    Radon concentration inside partially closed places like dwellings, caves and tombs, depends on many parameters. Some parameters are known quantitatively as radon exhalation rate for walls, decay constant, surface to volume ratio and outdoor concentration while other parameters as ventilation rate is in common known qualitatively due to useless of traditional methods (tracer gases) in many places as ancient Egyptian tombs. This work introduces a derived mathematical model to evaluate the sensitivity of radon concentration levels inside single sided opening places as ancient Egyptian tombs on the ambient temperature differences. The obtained formula for the natural ventilation rate depends on the indoor and outdoor temperature difference and the geometrical dimensions of the doorway. The effects of in and out flow mixing, air viscosity, streamline contraction, swirling flow and turbulence, were taken into consideration in terms of an empirical correction factor. According UNSCEAR reports, the exhalation rate Φ=C ra λ rn fρ s (1-ε)L; C ra the effective radium content, λ rn decay constant, f emanation fraction, ρ s soil grain density, ε porosity and L diffusion length, these are approximately static parameters but the variability of ambient temperature introduces a source of energy of fluctuating strength to radon atoms in rocks which controls the flow rate and the ambient content of radon. Therefore, the change of outdoor and indoor temperature difference causes fluctuation of value and direction of volume flow rate in such places consequently causes the daily variation and on average the seasonal variation of radon concentration. Therefore according to the present model, the daily accurate expectation of radon concentrations inside ancient Egyptian tombs, require precise measurements of indoor and outdoor temperatures

  11. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  12. Evaluation of annual effective dose from indoor radon concentration in Eastern Province, Dammam, Saudi Arabia

    Science.gov (United States)

    Abuelhia, E.

    2017-11-01

    The aim of this study is to determine the indoor radon concentration and to evaluate the annual effective dose received by the inhabitants in Dammam, Al-Khobar, and compare it with new premises built at university of dammam. The research has been carried out by using active detection method; Electronic Radon Detector (RAD-7) a solid state α-detector with its special accessories. The indoor radon concentration measured varies from 10.2 Bqm-3 to 25.8 Bqm-3 with an average value of 18.8 Bqm-3 and 19.7 Bqm-3 to 23.5 Bqm-3 with an average value of 21.7 Bqm-3, in Dammam and Al-khobar dwellings, respectively. In university of dammam the radon concentration varies from 7.4 Bqm-3 to 15.8 Bqm-3 with an average value of 9.02 Bqm-3. The values of annual effective doses were found to be 0.47mSv/y, 0.55mSv/y, and 0.23mSv/y, in Dammam, Al-khobar and university new premises, respectively. The average radon concentration in the old dwellings was two times compared to that in the new premises and it was 25.4 Bqm-3 lower than the world average value of 40 Bqm-3 reported by the UNSCEAR. The annual effective doses in the old dwellings was found to be (0.55mSv/y) two times the doses received at the new premises, and below the world wide average of 1.15mSv/y reported by ICRP (2010). The indoor radon concentration in the study region is safe as far as health hazard is concerned.

  13. Radon and radon progeny in 70 houses in the Tennessee Valley area: study design and measurement methods

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.; Quillen, J.L.; Clark, C. Jr.; Doane, R.W.; Wallace, R.G.; Reed, R.P.

    1986-01-01

    Levels of radon and its short-lived airborne progeny are being measured in a year-long study of 70 houses in four states in the Tennessee Valley. Various methods were used to solicit volunteers with differing degrees of success. Criteria for selection of houses in the study included presence of a lower level with cement floor and one or more block walls in contact with the soil, absence of obvious indications of technologically enhanced sources of radium, and proximity to one of four cities, (Knoxville, Chattanooga, Birmingham, or Florence). By design, most houses in the study are in the same neighborhood as at least one other house in the study. Houses range in age from newly constructed to about 40 years old. Most of the houses have more than 2000 square feet of finished floor space. The lower level encompasses a garage in most cases. More complete information pertaining to house characteristics will be gathered in the course of the study. Measurements are being made to obtain information on both location- and season-dependent variation of radon and radon progeny. Simultaneous measurements are made quarterly on both upper and lower levels of each house. Grab samples of air are collected and analyzed for radon using a modified Lucas cell technique. Short-term (10-minute) samples of airborne particulate material are collected and analyzed for radon progeny. One-week integrated measurements of working levels are made once each quarter using modified thermoluminescent dosimeters. Both three- and twelve-month integrated measurements of radon using track-etch monitors are being made. 19 references, 1 figures

  14. Airborne concentrations of Polybrominated diethyl etherin residential homes

    Directory of Open Access Journals (Sweden)

    S. Rahimzadeh

    2009-07-01

    Full Text Available Background and aims   Polybrominated diphenyl ethers (PBDE have been widely applied to different home and offices' appliances as flame retardant additives to inhibit ignition and enhance  the fire safety. Their toxicity, health effects, and resistance to environmental degradation are  matters of great interested among scientists. Airborne concentrations of PBDE in residential  homes were determined in this study.   Methods   In a cross sectional study, 33 residential homes were selected and airborne concentrations of PBDEs were investigated using PUF disk passive air samplers. Also in two building the concentraction of PBDEs were monitored in two rooms of a department in each building for 12 months.   Results   Average airborne concentration of ?PBDE (sum of congener #s 17, 28, 47, 49, 66, 85, 99, 100, 153, and 154 for all locations monitored was 52 (4-245 pgm -3 . While in one of the buildings the contaminant level of bedroom was significantly higher than the living room, PBDE   concentrations remained relatively constant for whole monitoring period.   Conclusion   The range of concentrations results to a wide variation between inhalation intakes of dwellers of the lowest and the highest contaminated homes (~50 folds.  

  15. Systematic measurements of the radon concentration indoor from Remetea, Harghita county

    International Nuclear Information System (INIS)

    Csegzi, Sandor

    2000-01-01

    Primary goal of the Remetea radon program was to carry out an indoor radon survey. The program can be applied too, in other places of the country. Remetea was built on volcanic rocks, where aligning of mineral water springs tells about the existence of geologic faulting. The 1992 census counted 2406 houses and 6550 residents of the village. The sample consisted of 120 houses chosen randomly from the entire stock. A hypergeometric statistical model has been used for sampling. Measurements were done in bedrooms at pillow level using etched track type Radamon radon detectors. Exposure lasted from January 1999 to July 1999. From the measurements it can be stated that the number of houses with radon concentration exceeding 200 Bq/m 3 is around 82. A high precision determination of activity has been done (errors under 3 %). Mapping indoor radon levels resembles the fault location that is indicated by springs and exhibited by geological studies. Particular points of the program were the soulful and self-aware approach the more than 30 schoolboys and girls participated, and the fact that the program met with a warm response from the public. (author)

  16. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  17. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  18. Plutonium concentrations in airborne soil at Rocky Flats and Hanford determined during resuspension experiments

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1978-01-01

    Plutonium resuspension results are summarized for experiments conducted by the author at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were far below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in μCi/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10 -4 to 10 4 . This uncertainty in the equality between plutonium concentrations per gram on airborne and surface soils is caused by only a fraction of the collected airborne soil being transported from offsite rather than all being resuspended from each study site and also by the great variabilities in surface contamination. Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same four orders of magnitude from 10 -7 to 10 -3 μCi/(m 2 day) for 239 Pu and 10 -8 to 10 -5 μCi/(m 2 day) for 238 Pu. Airborne respirable 239 Pu concentrations increased with wind speed for a southwest wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, 240 Pu/ 239 240 Pu, similar to weapons grade plutonium rather than fallout plutonium

  19. Predicted indoor radon concentrations from a Monte Carlo simulation of 1 000 000 granite countertop purchases

    International Nuclear Information System (INIS)

    Allen, J G; Zwack, L M; MacIntosh, D L; Minegishi, T; Stewart, J H; McCarthy, J F

    2013-01-01

    Previous research examining radon exposure from granite countertops relied on using a limited number of exposure scenarios. We expanded upon this analysis and determined the probability that installing a granite countertop in a residential home would lead to a meaningful radon exposure by performing a Monte Carlo simulation to obtain a distribution of potential indoor radon concentrations attributable to granite. The Monte Carlo analysis included estimates of the probability that a particular type of granite would be purchased, the radon flux associated with that type, the size of the countertop purchased, the volume of the home where it would be installed and the air exchange rate of that home. One million countertop purchases were simulated and 99.99% of the resulting radon concentrations were lower than the average outdoor radon concentrations in the US (14.8 Bq m −3 ; 0.4 pCi l −1 ). The median predicted indoor concentration from granite countertops was 0.06 Bq m −3 (1.59 × 10 −3 pCi l −1 ), which is over 2000 times lower than the US Environmental Protection Agency’s action level for indoor radon (148 Bq m −3 ; 4 pCi l −1 ). The results show that there is a low probability of a granite countertop causing elevated levels of radon in a home. (paper)

  20. Radon daughter concentrations in and around dwellings in the northern part of the Netherlands

    International Nuclear Information System (INIS)

    Wolfs, F.; Hofstede, H.; Meijer, R.J. de; Put, L.W.

    1984-01-01

    The concentration of radon daughters in and around 80 dwellings located in the northern part of the Netherlands has been determined using a one-filter method. Median values of 2.0 and 0.4 mWL were measured for the indoor and outdoor concentrations, respectively. The average outdoor concentration was about an order of magnitude higher for wind directions between SE-SW than for SW-NW. On average, dwellings with double pane windows and/or concrete floors were found to have significantly higher radon concentrations than those with single pane windows and/or wooden floors. For the living room of a particular dwelling, 18 measurements were carried out. The data for this dwelling indicate a linear relation between the concentration indoors and outdoors with a slope of 3.8 +- 2.0. This unexpected behaviour is thought to be related to ventilation via the crawl space. Measurements of ventilation patterns and measurements of radon concentrations in the living room and the crawl space are consistent with this picture. (author)

  1. Determination of Radon-222 and Thoron Concentration in Decorative Stone Warehouses Indoor Air and the Received Effective Dose by Staff

    Directory of Open Access Journals (Sweden)

    Amir Hossein Mahvi

    2015-06-01

    Full Text Available Background: Radon is a colorless, odorless, and radioactive gas that can be emitted from decorative stones such as granite, marble, etc. Inhaling radon gas in a long period may cause for incidence of lung cancer among peoples. Material and Methods: In this cross-sectional descriptive study, Radon 222 and Thoron concentrations in background and indoor air were measured in four decorative stones warehouse using portable radon meter(RTM1688-2 model. Totally, 24 samples of 24- hours concentrations in indoor air and 24 samples of 4-hours concentrations of Radon 222 and thoron in the background air at three stages were measured. Then, received effective dose of Radon 222 and Thoron was calculated by UNSCEAR equations. Results: The mean radon concentrations for indoor and background air were 74±37 and 34±16 Bq/m3, respectively. The mean radon concentrations for indoor air in decorative stones warehouses for DSW1, DSW2, DSW3 and DSW4 were 72.50±34, 98.25±43, 34.42±18 and 88.92±51 Bq/m3, respectively. The received effective dose mean of Radon 222 and Thoron by the staff at 8 working hours was 0.53±0.18 and 0.05±0.03 mSv/y and in 16 working hours was 1.05±0.36 and 0.11±0.07 mSv/y, respectively. Generally, the mean received effective dose by staff from Radon at 8 and 16 working hours was 0.58±0.2  and 1.16±0.41 mSv/y, respectively. Conclusions: Radon concentration mean in indoor air and the received effective dose mean by staff was lower than the standards level. Decorative stone warehouses were the resources for accumulation of Radon gas that can be reduced by corrective actions.

  2. Lung Cancer Mortality and Radon Concentration in a Chronically Exposed Neighborhood in Chihuahua, Mexico: A Geospatial Analysis

    Science.gov (United States)

    Hinojosa de la Garza, Octavio R.; Sanín, Luz H.; Montero Cabrera, María Elena; Serrano Ramirez, Korina Ivette; Martínez Meyer, Enrique; Reyes Cortés, Manuel

    2014-01-01

    This study correlated lung cancer (LC) mortality with statistical data obtained from government public databases. In order to asses a relationship between LC deaths and radon accumulation in dwellings, indoor radon concentrations were measured with passive detectors randomly distributed in Chihuahua City. Kriging (K) and Inverse-Distance Weighting (IDW) spatial interpolations were carried out. Deaths were georeferenced and Moran's I correlation coefficients were calculated. The mean values (over n = 171) of the interpolation of radon concentrations of deceased's dwellings were 247.8 and 217.1 Bq/m3, for K and IDW, respectively. Through the Moran's I values obtained, correspondingly equal to 0.56 and 0.61, it was evident that LC mortality was directly associated with locations with high levels of radon, considering a stable population for more than 25 years, suggesting spatial clustering of LC deaths due to indoor radon concentrations. PMID:25165752

  3. Radon activity concentrations and effective doses in ancient Egyptian tombs of the Valley of the Kings

    International Nuclear Information System (INIS)

    Hafez, A.F.; Hussein, A.S.

    2001-01-01

    Radon concentrations and equilibrium factors were measured in three pharaonic tombs during the year 1998. The tombs, which are open to the public are located in a limestone wadi on the West Bank of the River Nile at Luxor, 650 km south of Cairo. The radon activity concentration and equilibrium factor were measured monthly by two-integral nuclear track detectors (bare and diffusion detectors). Seasonal variation of radon concentrations, with summer maximum and winter minimum were observed in all tombs investigated. The yearly mean radon activity concentrations inside the tombs ranged from 540 to 3115 Bq m -3 . The mean equilibrium factor over a year was found to be 0.25 and 0.32 inside and at the entrance, respectively. Estimated annual effective doses to tour guides ranged from 0.33 to 1.90 mSv, visitors receive doses from 0.65 to 3.80 μSv per visit. The effective dose to tomb workers did not exceed the 20 mSv yr -1 limit

  4. Radon activity concentrations and effective doses in ancient Egyptian tombs of the Valley of the Kings.

    Science.gov (United States)

    Hafez, A F; Hussein, A S

    2001-09-01

    Radon concentrations and equilibrium factors were measured in three pharaonic tombs during the year 1998. The tombs, which are open to the public are located in a limestone wadi on the West Bank of the River Nile at Luxor, 650 km south of Cairo. The radon activity concentration and equilibrium factor were measured monthly by two-integral nuclear track detectors (bare and diffusion detectors). Seasonal variation of radon concentrations, with summer maximum and winter minimum were observed in all tombs investigated. The yearly mean radon activity concentrations insidc the tombs ranged from 540 to 3115 Bq m(-3). The mean equilibrium factor over a year was found to be 0.25 and 0.32 inside and at the entrance, respectively. Estimated annual effective doses to tour guides ranged from 0.33 to 1.90 mSv, visitors receive doses from 0.65 to 3.80 microSv per visit. The effective dose to tomb workers did not exceed the 20 mSv yr(-1) limit.

  5. Radon activity concentrations and effective doses in ancient Egyptian tombs of the Valley of the Kings

    Energy Technology Data Exchange (ETDEWEB)

    Hafez, A F; Hussein, A S

    2001-09-01

    Radon concentrations and equilibrium factors were measured in three pharaonic tombs during the year 1998. The tombs, which are open to the public are located in a limestone wadi on the West Bank of the River Nile at Luxor, 650 km south of Cairo. The radon activity concentration and equilibrium factor were measured monthly by two-integral nuclear track detectors (bare and diffusion detectors). Seasonal variation of radon concentrations, with summer maximum and winter minimum were observed in all tombs investigated. The yearly mean radon activity concentrations inside the tombs ranged from 540 to 3115 Bq m{sup -3}. The mean equilibrium factor over a year was found to be 0.25 and 0.32 inside and at the entrance, respectively. Estimated annual effective doses to tour guides ranged from 0.33 to 1.90 mSv, visitors receive doses from 0.65 to 3.80 {mu}Sv per visit. The effective dose to tomb workers did not exceed the 20 mSv yr{sup -1} limit.

  6. Study on radon concentration in groundwater of Sira and Tiptur taluk of Tumkur district, Karnataka, India

    Directory of Open Access Journals (Sweden)

    M B Karthik Kumar

    2017-01-01

    Full Text Available A study on radon concentration in groundwater samples collected from different villages of Sira and Tiptur taluk of Tumkur district has been conducted using emanometry method, and the effective dose to the public was estimated. The geometric mean of the activity concentration of dissolved radon was found to be 39.13 ± 1.99 and 3.78 ± 0.05 Bq/L for Sira and Tiptur taluk, respectively. The total annual effective dose for adult, children, and infants was also estimated and was found to be 0.20, 0.18, and 0.31 mSv/year, respectively, in Sira taluk and 0.019, 0.017, and 0.029 mSv/year in Tiptur taluk, respectively. Water samples were also analyzed for the physicochemical parameters to assess the quality of drinking water and also to understand the influence of these parameters on dissolved radon concentration. Poor correlation was observed between dissolved radon concentration and pH in both taluks.

  7. Spatial and time variations of radon-222 concentration in the atmosphere of a dead-end horizontal tunnel

    International Nuclear Information System (INIS)

    Richon, Patrick; Perrier, Frederic; Sabroux, Jean-Christophe; Trique, Michaeel; Ferry, Cecile; Voisin, Vincent; Pili, Eric

    2004-01-01

    The concentration of radon-222 has been monitored since 1995 in the atmosphere of a 2 m transverse dimension, 128 m long, dead-end horizontal tunnel located in the French Alps, at an altitude of 1600 m. Most of the time, the radon concentration is stable, with an average value ranging from 200 Bq m -3 near the entrance to about 1000 Bq m -3 in the most confined section, with an equilibrium factor between radon and its short-lived decay products varying from 0.61 to 0.78. However, radon bursts are repeatedly observed, with amplitudes reaching up to 36 x 10 3 Bq m -3 and durations varying from one to several weeks, with similar spatial variations along the tunnel as the background concentration. These spatial variations are qualitatively interpreted in terms of natural ventilation. Comparing the radon background concentration with the measured radon exhalation flux at the wall yields an estimate of 8 ± 2 x 10 -6 s -1 (0.03 ± 0.007 h -1 ) for the ventilation rate. The hypothesis that the bursts could be due to transient changes in ventilation can be ruled out. Thus, the bursts are the results of transient increased radon exhalation at the walls, that could be due to meteorological effects or possibly combined hydrological and mechanical forcing associated with the water level variations of the nearby Roselend reservoir lake. Such studies are of interest for radiation protection in poorly ventilated underground settings, and, ultimately, for a better understanding of radon exhalation associated with tectonic or volcanic processes

  8. Particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist Route “Liczyrzepa” Mine in Kowary Adit

    Directory of Open Access Journals (Sweden)

    Wołoszczuk Katarzyna

    2018-01-01

    Full Text Available Central Laboratory for Radiological Protection, in cooperation with Central Mining Institute performed measurements of radon concentration in air, potential alpha energy concentration (PAEC, particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist-Educational Route “Liczyrzepa” Mine in Kowary Adit. A research study was developed to investigate the appropriate dose conversion factors for short-lived radon progeny. The particle size distribution of radon progeny was determined using Radon Progeny Particle Size Spectrometer (RPPSS. The device allows to receive the distribution of PAEC in the particle size range from 0.6 nm to 2494 nm, based on their activity measured on 8 stages composed of impaction plates or diffusion screens. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometres to about 20 micrometres using Aerodynamic Particle Sizer (APS spectrometer and the Scanning Mobility Particle Sizer Spectrometer (SMPS.

  9. Rapid determination of radon daughters and of artificial radionuclides in air by online gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1993-01-01

    For the determination of airborne radionuclide concentrations in real time, a fixed filter device was constructed which fits directly onto a germanium detector with standard nuclear electronics and a multichannel analyzer buffer connected via a data line to a personal computer for remote control and on-line spectrum evaluation. The on-line gamma-ray spectrometer was applied to the study of radon decay product concentrations in ground-level air and to the rapid detection of only contamination of the environmental air by artificial radionuclides. At Munich-Neuherberg, depending on the meteorological conditions, the measured air concentrations of 214 Pb, the first gamma-ray-emitting member of the 222 Rn decay series, varied from about 1 to 50 Bq m -3 . For the artifical radionuclides 60 Co, 131 I and 137 Cs the detection limits were determined as a function of the varying natural radon daughter concentrations at sampling and counting times of 1 h or 1 day. For these radionuclides minimum detectable air activity concentrations of 0.3 or 0.001 Bq m -3 , respectively, were obtained at low radon daughter levels. At high radon daughter levels the respective detection limits were found to be higher by a factor of only about 2. (orig.)

  10. Rapid determination of radon daughters and of artificial radionuclides in air by online gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Winkler, R. (GSF-Forschungszentrum fuer Umwelt und Gesundheit, Neuherberg (Germany). Inst. fuer Strahlenschutz)

    1993-04-01

    For the determination of airborne radionuclide concentrations in real time, a fixed filter device was constructed which fits directly onto a germanium detector with standard nuclear electronics and a multichannel analyzer buffer connected via a data line to a personal computer for remote control and on-line spectrum evaluation. The on-line gamma-ray spectrometer was applied to the study of radon decay product concentrations in ground-level air and to the rapid detection of only contamination of the environmental air by artificial radionuclides. At Munich-Neuherberg, depending on the meteorological conditions, the measured air concentrations of [sup 214]Pb, the first gamma-ray-emitting member of the [sup 222]Rn decay series, varied from about 1 to 50 Bq m[sup -3]. For the artifical radionuclides [sup 60]Co, [sup 131]I and [sup 137]Cs the detection limits were determined as a function of the varying natural radon daughter concentrations at sampling and counting times of 1 h or 1 day. For these radionuclides minimum detectable air activity concentrations of 0.3 or 0.001 Bq m[sup -3], respectively, were obtained at low radon daughter levels. At high radon daughter levels the respective detection limits were found to be higher by a factor of only about 2. (orig.).

  11. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  12. The Reference Laboratory for Radon Gas Activity Concentration Measurements at PSI; Das Referenzlabor fuer Radongas-Konzentrationsmessungen am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Schuler, Christoph

    1998-09-01

    Active or passive radon gas measuring instruments are exposed during intercomparison exercises in the radon chamber of the Reference Laboratory for Radon Gas Concentration Measurements at Paul Scherrer Institut: The traceability of radon gas measurements to nationally and internationally acknowledged standards is inspected in the reference atmosphere of the chamber with calibrated {sup 222}Rn activity concentration. The use of secondary standards guarantees the traceability of the radon chamber reference atmosphere. Besides the principal secondary standard, a radon gas standard (secondary standard I), a {sup 226}Ra standard solution (secondary standard II) and a {sup 222}Rn emanation standard (secondary standard III) are used. The {sup 222}Rn activity delivered by one of these standards is quantitatively transferred into a reference volume and hence converted to an activity concentration serving for the calibration of a measuring instrument transfer standard consisting of scintillation cell and counter. By this way, the transfer standard calibration is related and traceable to the internationally acknowledged primary standard laboratories National Institute of Standards and Technology, Gaithersburg, Maryland (U.S.A.) or National Physical Laboratory, Teddington, Middlesex (UK). The calibrated transfer standard is then used to calibrate the radon gas activity concentration in the radon chamber. For a single grab sampling determination of the {sup 222}Rn activity concentration in the radon chamber with the transfer standard, the estimation of Type A and Type B uncertainties yields a relative expanded uncertainty (95% confidence level) of minimum 3% for high concentration levels (10 kBqm{sup -3}) and maximum 30% for low concentration levels (0.2 kBqm{sup -3}). Extended evaluations of the reproducibility of calibration factor measurements obtained by calibration of the transfer standard with the secondary standards I, II and III show a very good reproducibility quality

  13. Modeling the dependency of radon concentration levels inside ancient Egyptian tombs on the ambient temperature variations

    Energy Technology Data Exchange (ETDEWEB)

    Metwally, S M; Abo-Elmagdb, M [Faculty of Science, Department of Physics, Ain Shams University, P. O. Box 11566, Cairo (Egypt); Salamaa, E [National Institute for Standard, Radiation Measurements Department, Cairo (Egypt)

    2007-06-15

    Radon concentration inside partially closed places like dwellings, caves and tombs, depends on many parameters. Some parameters are known quantitatively as radon exhalation rate for walls, decay constant, surface to volume ratio and outdoor concentration while other parameters as ventilation rate is in common known qualitatively due to useless of traditional methods (tracer gases) in many places as ancient Egyptian tombs. This work introduces a derived mathematical model to evaluate the sensitivity of radon concentration levels inside single sided opening places as ancient Egyptian tombs on the ambient temperature differences. The obtained formula for the natural ventilation rate depends on the indoor and outdoor temperature difference and the geometrical dimensions of the doorway. The effects of in and out flow mixing, air viscosity, streamline contraction, swirling flow and turbulence, were taken into consideration in terms of an empirical correction factor. According UNSCEAR reports, the exhalation rate {phi}=C{sub ra}{lambda}{sub rn} f{rho}{sub s}(1-{epsilon})L; C{sub ra} the effective radium content, {lambda}{sub rn} decay constant, f emanation fraction, {rho}{sub s} soil grain density, {epsilon} porosity and L diffusion length, these are approximately static parameters but the variability of ambient temperature introduces a source of energy of fluctuating strength to radon atoms in rocks which controls the flow rate and the ambient content of radon. Therefore, the change of outdoor and indoor temperature difference causes fluctuation of value and direction of volume flow rate in such places consequently causes the daily variation and on average the seasonal variation of radon concentration. Therefore according to the present model, the daily accurate expectation of radon concentrations inside ancient Egyptian tombs, require precise measurements of indoor and outdoor temperatures.

  14. Optimisation of elevated radon concentration measurement by using electro-chemical etching of nuclear track detectors

    International Nuclear Information System (INIS)

    Celikovic, I.; Ujic, P.; Fujimoto, K.; Tommasino, L.; Demajo, A.; Zunic, Z.; Celikovic, I.)

    2007-01-01

    In the paper, two methods for adjusting of passive radon-thoron discriminative dosimeters (UFO detector) for enhanced radon concentration measurement are presented. Achieved upper limit of detection is 5.94 MBq m-3 d [sr

  15. Radon concentrations in drinking water in Wakasa area, Fukui Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Tokuyama, Hideki; Igarashi, Shuichi [Fukui Prefectural Environmental Radiation Research and Monitoring Center, Tsuruga (Japan)

    1997-02-01

    Radon concentration in drinking water was surveyed to make basic data for the investigation of radiation dose due to natural radioisotopes in the general public. Here, the survey data in the Wakasa region were reported. Sampling was carried out at 126 points in this region (ca. 70x50 km{sup 2}). A total of 167 samples were taken from the tap of private wells, and small and large public water supplies. The radon concentration was determined by direct measuring method. The mean concentration of ground water from the wells was 28.5 Bq/l, significantly higher than those of the tap water from small and large water supplies, 5.0 and 11.2 Bq/l, respectively. Rn concentration of ground water was dependent on geological features and it was comparatively high in the granite region. Ground water containing a high concentration of Rn was mixed into the water of some large water supply in the cities, showing that its Rn concentration was higher compared to those for the small water supply. This survey was conducted only in the winter seasons from 1989 to 1993. Therefore, there are no data concerning seasonal changes in Rn concentration to drinking water. (M.N.)

  16. The seasonal variation of radon concentration in the atmosphere of Chichi-jima island in the pacific ocean

    International Nuclear Information System (INIS)

    Yoshioka, Katsuhiro

    2008-01-01

    We continuously measured the radon concentration from April 2001 to December 2004 in Chichi-jima Is. We expect that the radon concentration at Chichi-jima Is. would be influenced only by the air mass transported through the long distance. The hourly values had very large variations, ranging from 0.2 to 6.0 Bqm -3 . No diurnal periodicity was found in the variation of the radon concentration. We found that the monthly averages of the radon concentration had a clear long term pattern, showing the highest in the winter and the lowest in the summer. To analyze the radon long time variation, an arriving air mass is grouped into five sectors according to the backward trajectory. Sector I is the sea areas surrounding Chichi-jima Is. Sector II including Philippines, Indonesia and the southeast Asia is spread the southwestern Pacific Ocean from Chichi-jima Is. and sector V is spread the northeastern way to the southeast. Sector III includes China, Mongolia, Korea and the western Japan region and sector IV two regions of the eastern Siberia and the eastern Japan. The radon long time variation showed a high positive correlation between the number of arrivals of the continental air mass, while strong negative correlation between the maritime air mass. (author)

  17. Plutonium concentrations in airborne soil at Rocky Flats and Hanford determined during resuspension experiments

    Energy Technology Data Exchange (ETDEWEB)

    Sehmel, G.A.

    1978-01-01

    Plutonium resuspension results are summarized for experiments conducted by the author at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were far below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in ..mu..Ci/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10/sup -4/ to 10/sup 4/. This uncertainty in the equality between plutonium concentrations per gram on airborne and surface soils is caused by only a fraction of the collected airborne soil being transported from offsite rather than all being resuspended from each study site and also by the great variabilities in surface contamination. Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same four orders of magnitude from 10/sup -7/ to 10/sup -3/ ..mu..Ci/(m/sup 2/ day) for /sup 239/Pu and 10/sup -8/ to 10/sup -5/ ..mu..Ci/(m/sup 2/ day) for /sup 238/Pu. Airborne respirable /sup 239/Pu concentrations increased with wind speed for a southwest wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, /sup 240/Pu//sup 239/ /sup 240/Pu, similar to weapons grade plutonium rather than fallout plutonium.

  18. Determining Radium-226 concentration from Radon-222 emanation in building materials: a theoretical model

    International Nuclear Information System (INIS)

    Barreto, Rafael C.; Perna, Allan F.N.; Narloch, Danielle C.; Del Claro, Flavia; Correa, Janine N.; Paschuk, Sergei A.

    2017-01-01

    It was developed an improved theoretical model capable to estimate the radium concentration in building materials solely measuring the radon-222 concentration in a con ned atmosphere. This non-destructive technique is not limited by the size of the samples, and it intrinsically includes back diffusion. The resulting equation provides the exact solution for the concentration of radon-222 as a function of time and distance in one dimension. The effective concentration of radium-226 is a fit parameter of this equation. In order to reduce its complexity, this equation was simplified considering two cases: low diffusion in the building material compared to the air, and a building material initially saturated with radon-222. These simplified versions of the exact one dimension solution were used to t experimental data. Radon-222 concentration was continuously measured for twelve days with an AlphaGUARD TM detector, located at the Laboratory of Applied Nuclear Physics at Universidade Tecnologica Federal do Parana (UTFPR). This model was applied to two different materials: cement mortar and concrete, which results were respectively (15:7 ±8:3) Bq=kg and (10:5±2:4) Bq=kg for the radium-226 effective concentration. This estimation was confronted with the direct measurements of radium in the same materials (same sources) using gamma-ray spectrometry, fulfilled at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), which results were respectively (13:81±0:23) Bq=kg and (12:61±0:22) Bq=kg. (author)

  19. Determining Radium-226 concentration from Radon-222 emanation in building materials: a theoretical model

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Rafael C.; Perna, Allan F.N.; Narloch, Danielle C.; Del Claro, Flavia; Correa, Janine N.; Paschuk, Sergei A., E-mail: baarreth@gmail.com, E-mail: allan_perna@hotmail.com, E-mail: daninarloch@hotmail.com, E-mail: aviadelclaro@gmail.com, E-mail: janine_nicolosi@hotmail.com, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica e Departamento Academico de Construcao Civil

    2017-07-01

    It was developed an improved theoretical model capable to estimate the radium concentration in building materials solely measuring the radon-222 concentration in a con ned atmosphere. This non-destructive technique is not limited by the size of the samples, and it intrinsically includes back diffusion. The resulting equation provides the exact solution for the concentration of radon-222 as a function of time and distance in one dimension. The effective concentration of radium-226 is a fit parameter of this equation. In order to reduce its complexity, this equation was simplified considering two cases: low diffusion in the building material compared to the air, and a building material initially saturated with radon-222. These simplified versions of the exact one dimension solution were used to t experimental data. Radon-222 concentration was continuously measured for twelve days with an AlphaGUARD{sup TM} detector, located at the Laboratory of Applied Nuclear Physics at Universidade Tecnologica Federal do Parana (UTFPR). This model was applied to two different materials: cement mortar and concrete, which results were respectively (15:7 ±8:3) Bq=kg and (10:5±2:4) Bq=kg for the radium-226 effective concentration. This estimation was confronted with the direct measurements of radium in the same materials (same sources) using gamma-ray spectrometry, fulfilled at Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), which results were respectively (13:81±0:23) Bq=kg and (12:61±0:22) Bq=kg. (author)

  20. A study on the environmental behavior of global air pollutants based on the continuous measurements of atmospheric radon concentrations

    International Nuclear Information System (INIS)

    Iida, Takao; Yamazawa, Hiromi

    2003-01-01

    Radon is a useful natural radioactive tracer of air transportation of atmospheric pollution, since radon is a noble gas and chemically inert. The atmospheric radon concentration is usually measured by a high-sensitivity electrostatic collection method or a two-filter method. The variations of radon concentrations observed over a solitary island and in the upper atmosphere are suitable for comparing with those of air pollutants. Some numerical simulation models were used to study the radon global transport in the atmosphere. In East Asia, atmospheric radon and air pollutants are transported with the air stream from the continent of China to the Northwestern Pacific Ocean. It is necessary to clarify the transport mechanism from both radon observations at various locations and numerical simulation. (author)

  1. A study of some factors which are related to indoor radon concentrations in Greece

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Lobotesi, E.; Mavroudaki, E.; Koukouliou, V.K.; Chanioti, M.; Papadimitriou, D.; Yiakoumakis, M.; Proukakis, C.

    1997-01-01

    The Medical Physics Department of the University of Athens is conducting radon-222 measurements in Greek dwellings. It is well known that the concentration of radon gas indoors, are related to various factors. A study of these factors has started and first results are reported. (authors)

  2. Analysis of queuing mine-cars affecting shaft station radon concentrations in Quzhou uranium mine, eastern China

    Directory of Open Access Journals (Sweden)

    Changshou Hong

    2018-04-01

    Full Text Available Shaft stations of underground uranium mines in China are not only utilized as waiting space for loaded mine-cars queuing to be hoisted but also as the principal channel for fresh air taken to working places. Therefore, assessment of how mine-car queuing processes affect shaft station radon concentration was carried out. Queuing network of mine-cars has been analyzed in an underground uranium mine, located in Quzhou, Zhejiang province of Eastern China. On the basis of mathematical analysis of the queue network, a MATLAB-based quasi-random number generating program utilizing Monte-Carlo methods was worked out. Extensive simulations were then implemented via MATALB operating on a DELL PC. Thereafter, theoretical calculations and field measurements of shaft station radon concentrations for several working conditions were performed. The queuing performance measures of interest, like average queuing length and waiting time, were found to be significantly affected by the utilization rate (positively correlated. However, even with respect to the “worst case”, the shaft station radon concentration was always lower than 200 Bq/m3. The model predictions were compared with the measuring results, and a satisfactory agreement was noted. Under current working conditions, queuing-induced variations of shaft station radon concentration of the study mine are not remarkable. Keywords: Hoist and Transport Systems, Mine-cars, Queuing Simulation, Radon Concentration, Underground Uranium Mine

  3. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  4. A retrospective study of radon daughter concentrations in the workplace in the fluorspar mines of St. Lawrence, Newfoundland

    International Nuclear Information System (INIS)

    Corkhill, D.A.; Dory, A.B.

    1984-07-01

    Fluorspar mining began in St. Lawrence, Newfoundland in the early thirties. In the early years the existing economic and social conditions resulted in poor health and safety practices in the mines. A high incidence of many types of pulmonary diseases, including lung cancer, among the miners was investigated by the Department of National Health and Welfare, and by 1960 radiation in the mines was recognized as the major cause. The original epidemiological study used radon daughter exposure estimates determined from a limited number of radon daughter measurements in one of the mines. Insufficient experience existed at that time to allow a proper technical assessment of the mines and to modify the estimated radon daughter concentrations accordingly. A review of the environmental conditions in the early years of mining and a revision of the estimates of radon daughter concentrations in those mines is presented. Environmental working conditions were determined based on a review of maps, inspectors' reports, Commission hearings, recollections of former workers and of the authors. Comparison to the conditions in the mines in later years, when radiation samples were taken more frequently allowed estimations of the probable radon daughter concentrations that would have existed in the mines earlier. Ranges of estimated average concentrations were made by mines for each year and wherever possible for broad types of job classes. Rather than attempting to propose single numbers for radon daughter concentrations, which in turn might have implied an accuracy that did not exist, ranges of average radon daughter concentrations were estimated

  5. Determination of the radon concentration in soil and ground water and its association with the seismicity

    International Nuclear Information System (INIS)

    Pena, P.; Segovia, N.; Azorin, J.

    2003-01-01

    The coast of the Mexican Pacific is one of the seismic areas more active of the world due to the subduction of the badges of Coconuts and Rivera under the badge of North America. The earthquakes that happen in this part of Mexico they are of great magnitude and they affect to the central plateau of the country where finds the biggest population density. On the other hand the coast of the Gulf of Mexico presents one relatively low seismic activity. It is in this region where it is the nuclear plant of Laguna Verde (PNLV) and the studies of seismicity of the area should be carried out for questions of nuclear security. One carries out a study of fluctuations of the concentration of the radon in floor and it dilutes underground in the mentioned areas using accustomed to detectors of nuclear appearances (LR-115). Possibly they were also used detecting automatic (Clipperton sounds out). In some cases it was analysed the gamma radiation in soil using thermoluminescent dosemeters (CaSO 4 : Dy + Ptfe). The mineralogical composition of rock samples was obtained, by means of technical conventional and Electron scanning microscopy and an X-ray diffractometer. The study one carries out along the coast of Guerrero, from Guacamayas, Mich. until Marquelia, Gro., of 1993 at 1998 and in the coast of the Gulf of Mexico, in the PNLV and their surroundings, of 1994 at 1996. The fluctuations of the radon concentration and of the gamma radiation, were analysed in function of the local seismic activity, the meteorological parameters and those characteristic geologic. In the area of the PNLV, the results showed that in general the averages of those value of the radon concentration, as much in floor as in water, they were low. A station located in a flaw area (New Ranch) the one that I present the values was but high of radon concentration, corresponding those but first floor to the PNLV. The seismic activity during the one period of sampling was sporadic and of low intensity and alone one

  6. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  7. Concentration levels of radon in air, indoors and outdoors in houses of Mexico City

    International Nuclear Information System (INIS)

    Pena Garcia, P.

    1992-01-01

    Concentration levels of radon in air, indoors and outdoors have been obtained in houses from Mexico City, with the purpose of relating them with the local environment. Measurements were performed both outdoors and indoors in 60 unifamiliar houses. Track detectors, LR-115, Type II, were used in several detection arrangements during four recording periods with times of exposure of three months each, with the purpose of analyzing the fluctuations due to seasonal changes. Data were obtained about the construction materials were the detection systems were located in order to establish a correlation of radon levels with the climatic parameters and the construction materials. The results of radon concentrations both indoors or outdoors were lower than the international recommendations (148 Bq/m 3 ) (Author)

  8. Hierarchical modeling of indoor radon concentration: how much do geology and building factors matter?

    Science.gov (United States)

    Borgoni, Riccardo; De Francesco, Davide; De Bartolo, Daniela; Tzavidis, Nikos

    2014-12-01

    Radon is a natural gas known to be the main contributor to natural background radiation exposure and only second to smoking as major leading cause of lung cancer. The main concern is in indoor environments where the gas tends to accumulate and can reach high concentrations. The primary contributor of this gas into the building is from the soil although architectonic characteristics, such as building materials, can largely affect concentration values. Understanding the factors affecting the concentration in dwellings and workplaces is important both in prevention, when the construction of a new building is being planned, and in mitigation when the amount of Radon detected inside a building is too high. In this paper we investigate how several factors, such as geologic typologies of the soil and a range of building characteristics, impact on indoor concentration focusing, in particular, on how concentration changes as a function of the floor level. Adopting a mixed effects model to account for the hierarchical nature of the data, we also quantify the extent to which such measurable factors manage to explain the variability of indoor radon concentration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Estimation of the variations of ventilation rate and indoor radon concentration using the observed wind velocity and indoor-outdoor temperature difference

    International Nuclear Information System (INIS)

    Nagano, Katsuhiro; Inose, Yuichi; Kojima, Hiroshi

    2006-01-01

    The indoor radon concentration in the building depends on the ventilation rate. Measurement results of indoor-outdoor pressure difference showed the ventilation rate correlated closely with the indoor-outdoor pressure difference. The observation results showed that one of factor of indoor-outdoor pressure difference was the wind velocity. When the wind velocity is small, the ventilation rate is affected by the indoor-outdoor temperature difference and the effect depends on the wind velocity. The temporal variation of indoor radon concentration was predicted by the time depending indoor radon balance model and the ventilation rate estimated from the wind velocity and the indoor-outdoor temperature difference. The temporal variations of predicted radon concentration gave good agreement with the experimental values. The measurement method, indoor radon concentration and ventilation rate, factors of temporal variation of ventilation rate, and prediction of indoor radon concentration are reported. (S.Y.)

  10. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation

    International Nuclear Information System (INIS)

    Berico, M.; Castellani, C. M.; Formignani, M.; Mariotti, F.

    2001-01-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F e q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F e q, f p ) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented [it

  11. Measurements of radon concentrations in a sample representative of housing in Franche-Comte

    International Nuclear Information System (INIS)

    Aury, K.; Clinard, F.; Tillier, C.; Catelinois, O.; Pirard, P.; Aury, K.; Nourry, L.; Hochart, A.

    2008-01-01

    Three departments on four ones in Franche-Comte are classified at risk for radon: measurements are so compulsory in establishments receiving public. For the residential sector, no obligation of measurement are compulsory when french people spend 70% of their time in it. The data concerning homes are fragmentary and deserve to be completed. This campaign of measurements has confirmed the existence of radon in relatively high concentrations in Franche-Comte, including the sedimentary areas, justifying the necessity to realize a precise evaluation of the sanitary impact. The model will allow to study different strategies to reduce radon in houses. (N.C.)

  12. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  13. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  14. Radiometric maps of Israel - Partial contribution to the understanding of potential radon emanations

    International Nuclear Information System (INIS)

    Vulkan, U.; Shirav, M.

    1997-01-01

    An airborne radiometric survey over parts of Israel was carried out in 1981. The system was comprised from 10 Nal 4 inch x 4 inch x 16 inch detectors, arranged in 4,4 and 2 sensors, with total volume of 1560 inch 3 , and one 4 inch x 4 inch x 16 inch uplooking Nal detector. Flight nominal height was 400 feet. It was found that the Mount Scopus Group (of Senonian origin) is the main source for high uranium - phosphorite rocks of this group contain up to 150 ppm U. Comparing the eU radiometric map with a map of potential radon emanation from rock units, reveals a fair correlation - high radon emanation usually follow the distribution of the Mount Scopus Group in Israel. The correlation between the two maps is excellent over arid terrain where soil cover is missing, whereas over semi-arid - humid areas (western and northern Israel), where soil and cultivation covers are developed, the eU levels over Mount Scopus Group's outcrops are much lower due to absorption of the radiation, and do not depict the full radon potential. Detailed mapping of radon hazards usually exhibit poor correlation between airborne eU data and direct pore radon measurements, even in arid terrain. This phenomenon is attributed to the fact that a radon ''source rock'' (e.g. phosphorite) could be covered with a few up to some tenths of meters of uranium-barren rock. About 0.5 meter cover is enough to absorb all radiation, causing very low airborne eU readings, while the radon free way in this rock is about 10 meters, yielding high pore radon levels when directly measured

  15. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  16. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  17. New developments in continuous monitoring of airborne activity

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1987-01-01

    Air monitors that operate continuously are used in nuclear facilities to detect unexpected malfunctions in controls that limit levels of airborne radioactivity in occupied area. Monitoring for concentrations of alpha-emitting transuranics is the most difficult task in air monitoring. Workplace monitoring for alpha emitters requires a detection level ∼2% that of nonalpha-emitting radionuclides with a half-life >2 h. Typically, air monitoring is accomplished by passing a volume of the monitored air through a filter to collect the particulates. The filter is located near a detector that monitors the radioactivity of the collected particles and sends an alarm when the activity exceeds established limits. Alpha activity from daughters of thoron and radon, present in all air in variable amounts, hampers monitoring for transuranics. This presentation describes developments that have improved the accuracy and sensitivity for the monitoring of airborne concentration of transuranics

  18. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    International Nuclear Information System (INIS)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R.; Denyak, Valeriy

    2013-01-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope 222 Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of 222 Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  19. Evaluation of radon-222 concentrations levels at workplaces of Curitiba, PR, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Perna, Allan F.N.; Reque, Marilson; Martins Neto, Manoel R., E-mail: flavia_delclaro@yahoo.com.br, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba - PR (Brazil); Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (FPP), Curitiba - PR (Brazil)

    2013-07-01

    The radon is noble radioactive gas, which when inhaled and undergoing spontaneous decay emits alpha particles that interacting with the cells of biological tissue stimulates the development of lung cancer. The isotope {sup 222}Rn is responsible for approximately half of the effective dose received by the population from natural radiation sources. Current work is focused at the evaluation of the radon concentration levels in air of different workplaces at Curitiba-PR. For this purpose 126 track-etched detectors CR-39 were mounted inside the diffusion chambers that were distributed at workplaces of three enterprises environments for a period of three months approximately. The diffusion chambers were protected by a borosilicate glass fiber filters. After the exposition in air the detectors were submitted to chemical etching using a solution of 6.25M NaOH at 70°C during 14 hours. Such chemical treatment enables to count alpha particle track using an optical microscope with 100x objective magnification. The density of alpha particle tracks in CR-39 was converted to the radon activity concentration in air using the results of previous calibration performed at the National Institute of Radiological Sciences (NIRS) in Japan. Obtained results show that the concentration of {sup 222}Rn in air at studied workplaces varied from 16±2 Bq/m³ to 78±9 Bq/m³. These values are considered within the limits established by international regulatory agencies such as EPA and ICRP, which consider as normal the radon activity up to 200 Bq/m³ and 148 Bq/m³, respectively. (author)

  20. Seasonal variations of radon concentrations in single-family houses with different sub-structures

    DEFF Research Database (Denmark)

    Majborn, B.

    1992-01-01

    Seasonal variations of indoor radon concentrations have been studied in 70 single-family houses selected according to the type of sub-structure and the type of soil underneath the house. Five categories of sub-structure were included - slab-on-grade, crawl space, basement, and combinations...... of basement with slab-on-grade or crawl space. Half of the houses are located on clayey till and the other half on glaciofluvial gravel. In each house radon was measured in a living room and a bedroom, in the basement if present, and in the crawl space if present and accessible. The measurements were made...... with track detectors on a quarterly basis throughout a year. For living rooms and bedrooms the seasonal variations range from being highly significant for the slab-on-grade houses to being insignificant for the crawl space houses. For basements and crawl spaces the geometric mean radon concentrations do...

  1. Uranium-238 and thorium-232 series concentrations in soil, radon-222 indoor and drinking water concentrations and dose assessment in the city of Alameda, Chihuahua, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Colmenero Sujo, L.; Montero Cabrera, M.E. E-mail: elena.montero@cimav.edu.mx; Villalba, L.; Renteria Villalobos, M.; Torres Moye, E.; Garcia Leon, M.; Garcia-Tenorio, R.; Mireles Garcia, F.; Herrera Peraza, E.F.; Sanchez Aroche, D

    2004-07-01

    High-resolution gamma spectrometry was used to determine the concentration of {sup 40}K, {sup 238}U and {sup 232}Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m{sup 3}; the radon concentrations detected exceeded 148 Bq/m{sup 3} in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m{sup 3}. The high activity of {sup 238}U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.

  2. Uranium-238 and thorium-232 series concentrations in soil, radon-222 indoor and drinking water concentrations and dose assessment in the city of Aldama, Chihuahua, Mexico.

    Science.gov (United States)

    Colmenero Sujo, L; Montero Cabrera, M E; Villalba, L; Rentería Villalobos, M; Torres Moye, E; García León, M; García-Tenorio, R; Mireles García, F; Herrera Peraza, E F; Sánchez Aroche, D

    2004-01-01

    High-resolution gamma spectrometry was used to determine the concentration of 40K, 238U and 232Th series in soil samples taken from areas surrounding the city of Aldama, in Chihuahua. Results of indoor air short-time sampling, with diffusion barrier charcoal detectors, revealed relatively high indoor radon levels, ranging from 29 to 422 Bq/m3; the radon concentrations detected exceeded 148 Bq/m3 in 76% of the homes tested. Additionally, liquid scintillation counting showed concentrations of radon in drinking water ranging from 4.3 to 42 kBq/m3. The high activity of 238U in soil found in some places may be a result of the uranium milling process performed 20 years ago in the area. High radon concentrations indoor and in water may be explained by assuming the presence of uranium-bearing rocks underneath of the city, similar to a felsic dike located near Aldama. The estimated annual effective dose of gamma radiation from the soil and radon inhalation was 3.83 mSv.

  3. A review of instrumentation for determination of radon and its daughters concentration

    International Nuclear Information System (INIS)

    Kurosawa, Ryuhei

    1989-01-01

    The aim of the review is to provide the aid for selection and understanding of the radon and its daughters measurement techniques which have been developed for radiation protection activities in various environments such as working of living environment. The practical purpose of the measurement for surveillance in environmental situation is the dose estimation for the public due to the inhalation of natural occurring radioactive materials. The techniques for the determination of radon and thoron concentratin by the active methods with the grab and continuous sampling, and also structures of radon monitors of various passive type are described. Explanation was made on the typical instruments for the determination of the potential alpha energy concentration (PAEC) of radon daughters by the various detecting systems such as solid state detector, and for the estimation of integrated PAEC in the various environments by the PAEC monitors using the cellulose nitrate film or TLD elements (author)

  4. [Airborne Fungal Aerosol Concentration and Distribution Characteristics in Air- Conditioned Wards].

    Science.gov (United States)

    Zhang, Hua-ling; Feng, He-hua; Fang, Zi-liang; Wang, Ben-dong; Li, Dan

    2015-04-01

    The effects of airborne fungus on human health in the hospital environment are related to not only their genera and concentrations, but also their particle sizes and distribution characteristics. Moreover, the mechanisms of aerosols with different particle sizes on human health are different. Fungal samples were obtained in medicine wards of Chongqing using a six-stage sampler. The airborne fungal concentrations, genera and size distributions of all the sampling wards were investigated and identified in detail. Results showed that airborne fungal concentrations were not correlated to the diseases or personnel density, but were related to seasons, temperature, and relative humidity. The size distribution rule had roughly the same for testing wards in winter and summer. The size distributions were not related with diseases and seasons, the percentage of airborne fungal concentrations increased gradually from stage I to stage III, and then decreased dramatically from stage V to stage VI, in general, the size of airborne fungi was a normal distribution. There was no markedly difference for median diameter of airborne fungi which was less 3.19 μm in these wards. There were similar dominant genera in all wards. They were Aspergillus spp, Penicillium spp and Alternaria spp. Therefore, attention should be paid to improve the filtration efficiency of particle size of 1.1-4.7 μm for air conditioning system of wards. It also should be targeted to choose appropriate antibacterial methods and equipment for daily hygiene and air conditioning system operation management.

  5. Risk assessment of exposure to radon concentration in indoor atmosphere and drinking water of Shimoga city, Karnataka, India

    International Nuclear Information System (INIS)

    Rangaswamy, D.R.; Sannappa, J.; Srinivasa, E.

    2016-01-01

    The exposure of population to natural sources of radiation has become an important issue in terms of radiological protection. The major contribution of dose from natural radiation in normal background regions arises due to inhalation of alpha-emitting radon and thoron, and their progenies, which are ubiquitous in both indoor and outdoor environs. The aim of the present study is to measure indoor radon, thoron and their progeny levels in the dwellings of Shimoga city and radon concentration in drinking water and to estimate the annual effective dose. The indoor concentration of radon, thoron and their progeny was measured using Solid-State Nuclear Track Detectors (SSNTDs) based twin chamber dosimeter cups. The 222 Rn concentration in drinking water was estimated by the Emanometry technique

  6. Gamma radiation and radon concentration levels at the radioactive waste repositories 'Richard' and 'Bratrstvi'

    International Nuclear Information System (INIS)

    Berka, Z.; Sabol, J.; Janu, M.

    1998-01-01

    Owing to the fact that cosmic rays are shielded off, the photon equivalent dose rates in the corridors of the Richard repository are usually slightly lower than outside. However, in points close to barrels containing radioactive waste, the dose rates can reach values as high as tens of μSv/h. Because of high concentrations of natural radionuclides, the dose rates in the Bratrstvi repository is generally considerably higher, as much as 5 times the normal background value. Radon concentrations exhibit specific time variations which are modified by ventilation. Where ventilation is poor or absent, the radon concentrations are extremely high, viz. up to 30 and 300 kBq/m 3 in the Richard and Bratrstvi repositories, respectively. Personal exposure of workers depend on the total time spent underground and on the ventilation rate. While the contribution from photons can be kept below the relevant limits, the radon-related doses may be significant and even exceed the professional limits if no precautions are taken. (P.A.)

  7. Appendix to radon and radon-daughter concentrations in air in the vicinity of the Anaconda Uranium Mill

    International Nuclear Information System (INIS)

    Momeni, M.H.; Lindstrom, J.B.; Dungey, C.E.; Kisieleski, W.E.

    1979-11-01

    Information is presented on the following subjects: site characteristics - stratigraphic description and water-bearing characteristics; meteorology - pooled observations made at two stations of windspeed, wind direction, and stability class; radon concentrations in air at various stations; and, frequencies of occurrence of given working levels at various stations

  8. Measurement of radon concentration in dwellings in the region of highest lung cancer incidence in India

    International Nuclear Information System (INIS)

    Zoliana, B.; Rohmingliana, P.C.; Sahoo, B.K.; Mayya, Y.S.

    2015-01-01

    Monitoring of radon exhalation from soil and its concentration in indoor is found to be helpful in many investigations such as health risk assessment and others as radiation damage to bronchial cells which eventually can be the second leading cause of lung cancer next to smoking. The fact that Aizawl District, Mizoram, India has the highest lung cancer incidence rates among males and females in Age Adjusted Rate (AAR) in India as declared by Population Based Cancer Registry Report 2008 indicates the need for quantification of radon and its anomalies attached to it. Measurement of radon concentration had been carried out inside the dwellings in Aizawl district, Mizoram. A time integrated method of measurement was employed by using a solid state nuclear track detector (SSNTD) type (LR-115 films) kept in a twin cup dosimeter for measurement of concentration of radon and thoron. The dosimeters were suspended over bed rooms or living rooms in selected dwellings. They were deployed for a period of about 120 days at a time in 63 houses which were selected according to their place of location viz. fault region, places where fossil remains were found and geologically unidentified region. After the desired period of exposure, the detectors were retrieved and chemically etched which were then counted by using a spark counter. The recorded nuclear tract densities are then converted into air concentrations of Radon and Thoron

  9. Influence of constructional energy-saving measures on the radon-concentration in the air in dwellings

    International Nuclear Information System (INIS)

    Grund, A.L.; Buermeyer, J.; Spizyn, A.; Zahradnik, I.; Grimm, V.; Grimm, G.; Gundlach, M.; Walpert, V.; Breckow, J.

    2015-01-01

    Due to energy-saving measures the air exchange in residential houses may be reduced. In order to determine time-dependent courses the indoor radon-concentrations were measured both, before and after renovation for several weeks. In addition, the most relevant climatic conditions or indoor climate factors, as e.g. the CO 2 -concentration, were measured. Verifying the renovation success, Blower-Door registered -Tests were performed, both as well before and after the renovation. Simultaneously the radon-concentration was measured. The results before and after renovation were compared with respect to seasonal parameters and the inhabitant's behavior. By investigation of the correlation coefficient the influencing parameters and the impact of the energy saving measures were analyzed. Based on the findings a model was developed to characterize the time-dependent course based on the influence quantities. The energy-saving measures at the building considerably influence the radon dynamics. Due to the denser building envelope, fresh air flows in case of underinflation caused by stack effect not only from the outside but even through the basement from the soil. Thus, by this path the radon-containing air can be transported into the dwelling's rooms as well. The influences of the users outweigh the influence of weather parameters, thus, the radonemission- rate was used for user-independent determination of the radon situation.

  10. The design and realization of calibration apparatus for measuring the concentration of radon in three models

    Energy Technology Data Exchange (ETDEWEB)

    Huiping, Guo [The Second Artillery Engineering College, Xi' an (China)

    2007-06-15

    For satisfying calibration request of radon measure in the laboratory, the calibration apparatus for radon activity measure is designed and realized. The calibration apparatus can auto-control and auto-measure in three models. sequent mode, pulse mode and constant mode. The stability and reliability of the calibration apparatus was tested under the three models. The experimental result shows that the apparatus can provides an adjustable and steady radon activity concentration environment for the research of radon and its progeny and for the calibration of its measure. (authors)

  11. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  12. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  13. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  14. Study on radon concentration monitoring using activated charcoal canisters in high humidity environments

    International Nuclear Information System (INIS)

    Wang Yuexing; Wang Haijun; Yang Yifang; Qin Sichang; Wang Zhentao; Zhang Zhenjiang

    2009-01-01

    The effects of humidity on the sensitivity using activated charcoal canisters for measuring radon concentrations in high humidity environments were studied. Every canister filled with 80 g of activated charcoal, and they were exposed to 48 h or 72 h in the relative humidity of 68%, 80%, 88% and 96% (28 degree C), respectively. The amount of radon absorbed in the canisters was determined by counting the gamma rays from 214 Pb and 214 Bi (radon progeny). The results showed that counts decreased with the increase of relative humidity. There was a negative linear relationship between count and humidity. In the relative humidity range of 68%-96%, the sensitivity of radon absorption decreased about 2.4% for every 1% (degree)rise in humidity. The results also showed that the exposure time of the activated charcoal canisters should be less than 3 days. (authors)

  15. Improvements in the detection of airborne plutonium

    International Nuclear Information System (INIS)

    Ryden, D.J.

    1981-02-01

    It is shown how it is possible to compensate individually for each of the background components on the filter paper used to collect samples. Experimentally it has been shown that the resulting compensated background count-rate averages zero with a standard deviation very close to the fundamental limit set by random statistical variations. Considerable improvements in the sensitivity of detecting airborne plutonium have been achieved. Two new plutonium-in-air monitors which use the compensation schemes described in this report are now available. Both have operated successfully in high concentrations of radon daughters. (author)

  16. A radon progeny deposition model

    International Nuclear Information System (INIS)

    Rielage, Keith; Elliott, Steven R.; Hime, Andrew; Guiseppe, Vincent E.; Westerdale, S.

    2010-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  17. A Radon Progeny Deposition Model

    International Nuclear Information System (INIS)

    Guiseppe, V. E.; Elliott, S. R.; Hime, A.; Rielage, K.; Westerdale, S.

    2011-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  18. Characteristics of radon concentration distributions measurement with two-filter method in the storage rooms of Ra-Be neutron source and the adjacent laboratories

    International Nuclear Information System (INIS)

    Liu Shuhuan; Chu Jun; Zhao Yaolin; Bao Lihong; Chen Wei; Wu Yuelei

    2012-01-01

    The basic principle of radon measurement with two-filter method is introduced in this paper. The levels of radon concentration in the storage rooms and the adjacent laboratories are measured and compared with the type of FT-648 radon measurement instrument. The measurement results showed that the levels of radon concentration in Ra-Be neutron source storage rooms are not higher than those in the adjacent laboratories, then it can be deduced that no radon gas was leaked out form the shielded and sealed Ra-Be neutron sources. The radon concentrations measured in the laboratories were near to the average level compared to the statistical results of the indoor dwellings' radon concentrations in Xi'an. The values didn't exceed the national standard limits(200 Bq·m -3 ). Furthermore, it is found that the radon concentration value measured at rainy or cloudy day is lesser than that at sunny day, and good ventilation conditions can effectively decrease the indoor radon concentration level. Meanwhile, the mechanisms of the radon concentration distributions in the laboratories influenced by the factors including various weather conditions (rainy, sunny and cloudy), ventilation and different measurement time periods in a day, etc. are primarily analyzed. The measurement results in this work provide some relative reference data for prediction the situations of Ra-Be neutron sources safety storage and experimenters' radiation protection in the laboratories. (authors)

  19. Radon measurements in indoor workplaces

    International Nuclear Information System (INIS)

    Tokonami, S.; Matsumoto, M.; Furukawa, M.; Fujimoto, K.; Fujitaka, K.; Pan, J.; Kurosawa, R.

    1996-01-01

    Radon measurements in several office buildings located in Tokyo were carried out with two types of device to study the time-dependent radon concentration in indoor workplaces. Both types of device use the electrostatic field for the collection of 218 Po onto the electrode of the detector. One provides an average radon concentration throughout the day. The other, in which a weekly timer is installed in the circuit of the electrode of the device, provides an average radon concentration during working hours (9:00-17:00, Monday-Friday). Although radon concentrations in Japanese dwellings have been found to be generally low, relatively high concentrations were observed in the office buildings. No consistent seasonal variation was recognised in this study. Little difference of average radon concentrations between working hours and the whole day was found throughout the year in two offices. On the other hand, a significant difference was observed in other offices. The operation of an air conditioner might change the radon concentration during working hours. From the results of radon measurements the average effective dose in the workplace was estimated to be 0.23 mSv for 2000 working hours in a year. (Author)

  20. Radon studies in Indian dwellings

    International Nuclear Information System (INIS)

    Khan, A.J.

    2000-01-01

    The indoor radon ( 222 Rn) concentration has been measured by Solid State Nuclear Track Detectors (SSNTDs) in large number of Indian dwellings. Radon concentrations were measured in different parts of the country. In the first study, radon concentrations were measured in 143 dwellings of Udaipur, Bikaner and Banswara towns of Rajasthan province. The distributions of the time-averaged indoor radon concentration in these three towns of the Rajasthan fit an approximately log normal distribution. The geometric mean (GM) values of radon concentrations in these three places were found to be 74 Bq m -3 , 46 Bq m -3 and 66 Bq m -3 with a geometric standard deviation (GSD) of 2.2, 2.2 and 2.5 respectively. In another study, radon concentrations were measured in about 150 dwellings of hilly regions of the country. The measurements were carried out in Kohima (Nagaland), Baijnath and Palampur (Himachal Pradesh). The distribution of radon concentration in Kohima dwellings was found to be approximately log normal, however, the radon distribution in Baijnath and Palampur dwellings seems to be bimodal. The GM values of the radon concentrations for 65 dwellings in Kohima and 43 dwellings in Baijnath and Palampur were 88 Bq m -3 and 134 Bq m -3 with GSD of 1.7 and 2.5 respectively. The results are discussed in detail. (author)

  1. Assessment of current techniques for reduction of indoor radon concentration in existing and new houses in European countries

    International Nuclear Information System (INIS)

    Holmgren, O.; Arvela, H.

    2012-03-01

    Radon control technologies aim at the reduction of indoor radon concentrations in existing buildings and in new construction through remedial and preventive measures. In recent years, rising ecological awareness and rising energy costs have stimulated the development of low energy and passive houses to save energy. This report contains the analysis and assessment of current techniques and technologies used to achieve the reduction of indoor radon concentrations in existing and new houses with regard to the reduction efficiency and potential impact on energy consumption (qualitative analysis). A questionnaire was prepared and sent to all RADPAR partners in 14 different countries in order to gather national information about the current remediation and prevention techniques. Responses with variable amounts of information were obtained. Based on the questionnaire responses, the status of radon remediation and prevention in each country was assessed, in addition to the reduction efficiency and potential impact on energy consumption of the current remediation and prevention techniques. The number of dwellings with an elevated indoor radon concentration typically ranges from tens of thousands to a million. The percentage of these houses already remediated varies from zero to 15%. Preventive measures in new construction have been taken from a small number of houses to over half a million houses. The research data on the current situation, the number of houses with preventive measures and the efficiency of these measures is currently still quite inadequate. Assessment of the techniques and also the surveys aiming at exploring the impact of remedial and preventive measures is greatly needed in order to promote the work at the national level. The most efficient remediation method is the active sub-slab depressurization (SSD) and the radon well, for which the reduction in the radon concentration is typically 70 - 95%. Other methods, such as sealing entry routes and improving

  2. Radon concentration measurements for determination of radiation dose and assessment of cancer risk in the premises of some colleges in Lahore, Pakistan

    International Nuclear Information System (INIS)

    Mahmood, A.; Tufail, M.; Iqbal, M.A.

    2010-01-01

    Radon concentration has been measured in campus and hostel buildings of some colleges in the city of Lahore. The technique of passive radon measurements was employed using CN-85 etched track detectors in the box type dosimeters. The observed radon concentration in different parts of monitored buildings was within the range 18-61 Bq m/sup -3/. The cause of radon in college buildings may be the construction materials, drinking water, natural gas, drainage, sewerage pipes, etc. Moving fans, open doors and windows in summer season diluted the radon concentration, while the air tight arrangement in the winter enhanced the radon concentration level. Alpha dose from radon to the students and supporting staff was estimated as 0.34 and 0.91 mSv y/sup -1/ in campus and hostel buildings respectively. The corresponding excess lifetime cancer risk attributed to the students and staff in the college campuses was found to be 0.20 %, while the staff and students residing in the hostels of the colleges received the excess lifetime risk of cancer 0.53 % due to radon progenies. (author)

  3. Study on radon concentration in ground water of Sira and Tiptur taluk of Tumkur district, Karnataka, India

    International Nuclear Information System (INIS)

    Karthik Kumar, M.B.; Nagaiah, N.; Mathews, Gladys; Ambika, M.R.

    2016-01-01

    Radon is a naturally occurring, odor less, tasteless, inert gas that cannot be detected by human senses but can be identified by different techniques. Radon has highest solubility in water, with the mole fraction of 1.25 x 10 -5 at 37 ° C which is fifteen times that of the neon and helium. Radon can enter into the human body in two different ways i.e. ingestion and inhalation which affects the human health. In view of this, activity concentration of dissolved 222 Rn was measured in potable water of Sira and Tiptur taluk of Tumkur district and attempts were also made to understand the dependence of dissolved radon concentration on pH, conductivity and the Total Dissolved Solids (TDS)

  4. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  5. Indoor randon concentration. Temperature and wind effects; Concentrazione di radon indoor. Effetto del vento e della temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, L.; Benigni, S. [Milan Univ., Milan (Italy). Ist. di Fisica Generale Applicata

    2000-12-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied. [Italian] Si analizza e si discute il comportamento della concentrazione di radon indoor nel seminterrato di una casa di ricerca. Misure orarie sono state effettuate da novembre 1998 a giugno 1999. In molte sequenze di giorni la concentrazione del radon nel locale in analisi presenta forti variazioni nel corso della giornata con un accumulo notturno e decrescita nelle ore diurne. Sono state eseguite misure della velocita' del vento, delle temperature outdoor e indoor e della differenza di pressione outdoor-indoor e il loro andamento e' stato confrontato con quello della concentrazione del radon. Vengono discusse l'esalazione del radon dalle pareti, dal pavimento e dal soffitto e l'esalazione pressure difference driven dal suolo. Il rateo dei ricambi d'aria tra il locale e l'aria outdoor e' studiato.

  6. Radon concentration in drinking water and water for living use and their study status

    International Nuclear Information System (INIS)

    Tan Chenglong

    2005-01-01

    Low quality water is the chief reason for resulting in decrease of human group's physique, and in early appearance of nutrition and supersession diseases. The assimilation of radon released from water by human body may cause radioactive impact to those organs such as stomach and lungs. The monitoring determination for chemical quality of drinking water in developed countries comprises as many as 350 items, and the maximum contamination level of international standards is adopted for checking the radon concentration in drinking water, However, at present, only 35 items of the chemical quality of drinking water are determined in China. The monitoring determination of radon concentration in running water of cities, in distillation water, mineral water, pure water, deep well water in country side, as well as natural surface water is of great market potential in the future. (authors)

  7. Identifying areas with potential for high indoor radon levels: analysis of the national airborne radiometric reconnaissance data for California and the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Moed, B.A.; Nazaroff, W.W.; Nero, A.V.; Schwehr, M.B.; Van Heuvelen, A.

    1984-04-01

    Radon-222 is an important indoor air pollutant which, through the inhalation of its radioactive decay products, accounts for nearly half of the effective dose equivalent to the public from natural ionizing radiation. Indoor radon concentrations vary widely, largely because of local and regional differences in the rate of entry from sources. The major sources are soil and rock near building foundations, earth-based building materials, and domestic water; of these, soil and rock are thought to be predominant in many buildings with higher-than-average concentrations. Thus, one key factor in determining radon source potential is the concentration of radium, the progenitor of radon, in surficial rocks and soils. Aerial radiometric data were analyzed, collected for the National Uranium Resource Evaluation Program, for seven Western states to: (1) provide information on the spatial distribution of radium contents in surficial geologic materials for those states; and (2) investigate approaches for using the aerial data, which have been collected throughout the contiguous United States and Alaska, to identify areas where high indoor radon levels may be common. Radium concentrations were found to be relatively low in central and western portions of Washington, Oregon, and northern California; they were found to be relatively high in central and southern California. A field validation study, conducted along two flight-line segments near Spokane, Washington, showed close correspondence between the aerial data, in situ measurements of both radium content and radon flux from soil, and laboratory measurements of both radium content of and radon emanation rate from soil samples. 99 references, 11 figures, 3 tables.

  8. Identifying areas with potential for high indoor radon levels: analysis of the national airborne radiometric reconnaissance data for California and the Pacific Northwest

    International Nuclear Information System (INIS)

    Moed, B.A.; Nazaroff, W.W.; Nero, A.V.; Schwehr, M.B.; Van Heuvelen, A.

    1984-04-01

    Radon-222 is an important indoor air pollutant which, through the inhalation of its radioactive decay products, accounts for nearly half of the effective dose equivalent to the public from natural ionizing radiation. Indoor radon concentrations vary widely, largely because of local and regional differences in the rate of entry from sources. The major sources are soil and rock near building foundations, earth-based building materials, and domestic water; of these, soil and rock are thought to be predominant in many buildings with higher-than-average concentrations. Thus, one key factor in determining radon source potential is the concentration of radium, the progenitor of radon, in surficial rocks and soils. Aerial radiometric data were analyzed, collected for the National Uranium Resource Evaluation Program, for seven Western states to: (1) provide information on the spatial distribution of radium contents in surficial geologic materials for those states; and (2) investigate approaches for using the aerial data, which have been collected throughout the contiguous United States and Alaska, to identify areas where high indoor radon levels may be common. Radium concentrations were found to be relatively low in central and western portions of Washington, Oregon, and northern California; they were found to be relatively high in central and southern California. A field validation study, conducted along two flight-line segments near Spokane, Washington, showed close correspondence between the aerial data, in situ measurements of both radium content and radon flux from soil, and laboratory measurements of both radium content of and radon emanation rate from soil samples. 99 references, 11 figures, 3 tables

  9. Comparison of techniques active and passive in measurement of radon concentration ("2"2"2Ra) in the air

    International Nuclear Information System (INIS)

    Oliveira, Evaldo Paulo de

    2017-01-01

    The purpose of this work was to perform a study comparing radon concentration measurements between two techniques used to measure radon gas in the air: one using LEXAN polycarbonate plastic detectors and the other the continuous monitor in AlphaGUARD passive mode. The concentrations of radon gas within radon emanation chambers were measured using calibrated / traceable sources generating "2"2"2Rn through "2"2"6Ra. In calibration the 'calibration factor' or 'sensitivity' was determined for the LEXAN plastic detector. The calibration work of the dosimeters was carried out at the Radon Laboratory of the Environmental Analysis Division - DIRAD IRD/CNEN and at the Natural Radioactivity Laboratory (LRN) of the Center for the Development of Nuclear Technology (CDTN/CNEN). The 'calibration factor' or 'sensitivity' was found to be 32.34 (traits.cm"-"2)/(kBq.d.m"-"3). This factor was used to determine the radon concentration measured by the LEXAN plastic detectors. Also in the calibration, the efficiencies for LEXAN (94.1% ± 9.7%) and AlphaGUARD (92.5% ± 7.2%) were determined. The statistical analysis used showed good parity in the results of the measurements. It was concluded that the results were satisfactory and will serve as a good reference for studies related to the radon air meters used in this work. (author)

  10. Uranium prospecting through radon detection; La prospection de l'uranium par le radon

    Energy Technology Data Exchange (ETDEWEB)

    Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Prospecting rests on the determination of the concentration of ground air in radon. Radon diffusing from deep uranium bearing layers is detected in upper ground layers. (author) [French] La prospection est basee sur l'etude de la concentration en radon dans l'air du sol. Dans les terrains superficiels, on decele le radon qui diffuse a partir des couches profondes uraniferes. (auteur)

  11. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  12. Radon and radon daughter measurements at and near the former Middlesex Sampling Plant, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    Haywood, F.F.; Perdue, P.T.; Christian, D.J.; Leggett, R.W.; Dickson, H.W.; Myrick, T.E.

    1980-03-01

    The results of the radon and radon daughter measurements made to date (1978) at the Middlesex Sampling Plant in Middlesex, New Jersey, are presented in this report. These measurements were one portion of a more comprehensive radiological survey conducted at this site and the surrounding area from 1976 to 1978. The surveyed property served as a uranium ore sampling plant during the 1940's and early 1950's and as a result contains elevated levels of surface an subsurface contamination. On-site indoor radon daughter and radon concentrations exceeded both the US Surgeon General Guidelines and the Nuclear Regulatory Commission's maximum permissible concentration limits for radon (10 CFR Part 20) in all structures surveyed. Off-site structures showed concentrations of radon and radon daughters at or only slightly above background levels, except for one site where the radon levels were found to be above the 10 CFR Part 20 guidelines. Outdoor radon ad radon daughter concentrations, measured both on and off the site, were well below the guidelines, and the data give no indication of significant radon transport from the site

  13. High annual radon concentration in dwellings and natural radioactivity content in nearby soil in some rural areas of Kosovo and Metohija

    Directory of Open Access Journals (Sweden)

    Gulan Ljiljana R.

    2013-01-01

    Full Text Available Some previous studies on radon concentration in dwellings of some areas of Kosovo and Metohija have revealed a high average radon concentration, even though the detectors were exposed for three months only. In order to better design a larger study in this region, the annual measurements in 25 houses were carried out as a pilot study. For each house, CR-39-based passive devices were exposed in two rooms for the two consecutive six-month periods to account for seasonal variations of radon concentration. Furthermore, in order to correlate the indoor radon with radium in nearby soil and to improve the knowledge of the natural radioactivity in the region, soil samples near each house were collected and 226Ra, 232Th, 40K activity concentration were measured. The indoor radon concentration resulted quite high from the average (163 Bq/m3 and generally it did not differ considerably between the two rooms and the two six-month periods. The natural radionuclides in soil resulted to be distributed quite uniformly. Moreover, the correlation between the226Ra content in soil and radon concentration in dwellings resulted to be low (R2=0.26. The annual effective dose from radon and its short-lived progeny (5.5 mSv, in average was calculated by using the last ICRP dose conversion factors. In comparison, the contribution to the annual effective dose of outdoor gamma exposure from natural radionuclides in soil is nearly negligible (66 mSv. In conclusion, the observed high radon levels are only partially correlated with radium in soil; moreover, a good estimate of the annual average of radon concentration can be obtained from a six-month measurement with a proper choice of exposure period, which could be useful when designing large surveys.

  14. High concentrations of radon. Specifically affected buildings; Hohe Radonkonzentrationen. Besonders betroffene Gebaeudetypen

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Winfried [Bundesamt fuer Strahlenschutz, Berlin (Germany)

    2015-07-01

    The paper presents a concept for the prognosis of exceeding probabilities of thresholds of radon in dwellings in different building types. A transfer model for the interface subsoil - building was used as a basis. The partial datasets obtained by stratification of five relevant building characteristics can be de-scribed by a 3-parametric-lognormal distribution good in most times. The available data permit statistical predictions to 60 combinations of building characteristics for the region ''east'' and 85 combinations of building characteristics for the region ''West''. The uncertainties for the probability of exceeding a threshold were estimated from the data with bootstrapping. The importance of different building characteristics for the presence of enhanced radon concentrations can be predicted from the results of this estimation. Therefore, targeting of affected buildings is possible on this basis. Regional prognoses of exceeding probabilities for building types with high presence can also be created by the use of transfer factors. A Strategy to reduce the health risk from radon in the long run might be derived, where alongside the delineation of radon prone areas, special attention should be paid to a set out building characteristics, also outside the radon prone areas.

  15. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  16. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  17. Temporal variations of radon concentration in the saturated soil of Alpine grassland: The role of groundwater flow

    International Nuclear Information System (INIS)

    Perrier, Frederic; Richon, Patrick; Sabroux, Jean-Christophe

    2009-01-01

    Radon concentration has been monitored from 1995 to 1999 in the soil of the Sur-Fretes ridge (French Alps), covered with snow from November to April. Measurements were performed at 70 cm depth, with a sampling time of 1 h, at two points: the summit of the ridge, at an altitude of 1792 m, and the bottom of the ridge, at an altitude of 1590 m. On the summit, radon concentration shows a moderate seasonal variation, with a high value from October to April (winter), and a low value from May to September (summer). At the bottom of the ridge, a large and opposite seasonal variation is observed, with a low value in winter and a high value in summer. Fluctuations of the radon concentration seem to be associated with temperature variations, an effect which is largely delusory. Indeed, these variations are actually due to water infiltration. A simplified mixing model is used to show that, at the summit of the ridge, two effects compete in the radon response: a slow infiltration response, rich in radon, with a typical time scale of days, and a fast infiltration of radon-poor rainwater. At the bottom of the ridge, similarly, two groundwater contributions compete: one slow infiltration response, similar to the response seen at the summit, and an additional slower response, with a typical time scale of about a month. This second slower response can be interpreted as the aquifer discharge in response to snow melt. This study shows that, while caution is necessary to properly interpret the various effects, the temporal variations of the radon concentration in soil can be understood reasonably well, and appear to be a sensitive tool to study the subtle interplay of near surface transfer processes of groundwater with different transit times

  18. Temporal variations of radon concentration in the saturated soil of Alpine grassland: the role of groundwater flow.

    Science.gov (United States)

    Perrier, Frédéric; Richon, Patrick; Sabroux, Jean-Christophe

    2009-03-15

    Radon concentration has been monitored from 1995 to 1999 in the soil of the Sur-Frêtes ridge (French Alps), covered with snow from November to April. Measurements were performed at 70 cm depth, with a sampling time of 1 h, at two points: the summit of the ridge, at an altitude of 1792 m, and the bottom of the ridge, at an altitude of 1590 m. On the summit, radon concentration shows a moderate seasonal variation, with a high value from October to April (winter), and a low value from May to September (summer). At the bottom of the ridge, a large and opposite seasonal variation is observed, with a low value in winter and a high value in summer. Fluctuations of the radon concentration seem to be associated with temperature variations, an effect which is largely delusory. Indeed, these variations are actually due to water infiltration. A simplified mixing model is used to show that, at the summit of the ridge, two effects compete in the radon response: a slow infiltration response, rich in radon, with a typical time scale of days, and a fast infiltration of radon-poor rainwater. At the bottom of the ridge, similarly, two groundwater contributions compete: one slow infiltration response, similar to the response seen at the summit, and an additional slower response, with a typical time scale of about a month. This second slower response can be interpreted as the aquifer discharge in response to snow melt. This study shows that, while caution is necessary to properly interpret the various effects, the temporal variations of the radon concentration in soil can be understood reasonably well, and appear to be a sensitive tool to study the subtle interplay of near surface transfer processes of groundwater with different transit times.

  19. Continual monitoring of radon decay products concentration in indoor and outdoor air

    International Nuclear Information System (INIS)

    Petruf, P.; Holy, K.; Stanys, T.

    1998-01-01

    The goal of this work was the development of the method and construction and testing of measurement device for continual monitoring of radon daughters concentrations in the indoor and outdoor environment with regard to make possible to determine very low activities in the outdoor air (below % Bq/m 3 ). In this method air sample is drawn through the appropriate filter material. Radon and thoron daughters both attached and unattached on aerosols particles are collected on the filter surface and then the filter activity is counted. The silicon surface barrier detector with the active area of 200 mm 2 in monitor was used. The Millipore AW19-type filter was chosen and sampling rate of 30 l/min for collecting of the air samples. The determination of the individual activity concentrations in three-count method is based on the solution of the simultaneous equations describing the number of atoms of measured nuclides on the filter during and after sampling. The monitor was tested in three different environments (the average values of the activity concentrations of radon and its decay products in Bq/m 3 are given): in the basement of the building: 61.4 ± 5.0 of 222 Rn, 29.5 ± 2.8 of 218 Po, 14.1 ± 1.8 of 214 Pb and 12.1 ± 1.6 of 214 Bi; in the room on the second floor of the same building:22.2 ± 7.9 of 222 Rn, 7.3 ± 2.8 of 218 Po, 4.6 ± 1.9 of 214 Pb and 2.6 ± 1.2 of 214 Bi ; in the outdoor air in front of the building: 4.1 ± 2.7 of 222 Rn, 2.3 ± 0.9 of 218 Po, 1.5 ± 0.8 of 214 Pb and 1.4 ± 0.6 of 214 Bi. The results show a good agreement with expectations of the activity concentrations in three different environments. The monitor enables to determine low activity concentrations in the outdoor with an acceptable precision during one hour counting. The monitor can be used for the research of the correlation between the atmospheric stability and activity concentrations of radon decay products

  20. Indoor radon concentration levels in Mexican caves, using nuclear track methodology, and the relationship with living habits of the bats

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Vega-Orihuela, E.; Morales-Malacara, J.B.

    2013-01-01

    This work presents the results of a study of the radon levels in four caves in Mexico: Los Riscos Cave and El Judio Cave in the State of Queretaro, and Coyozochico Cave and Karmidas Cave in the State of Puebla. The measurements were made using the passive closed-end cup system, with CR-39 (Lantrack R ) as detection material, and following protocols established for the measurement of indoor radon, developed at the Dosimetry Applications Project of the Physics Institute of the Universidad Nacional Autonoma de Mexico. The radon concentration at one location with Karmidas Cave reached more than 60,000 Bq/m 3 , while concentrations in the other three caves varied from 83.1-1216.0 Bq/m 3 , was found. During the study was observed an interesting coincidence between the radon concentration distribution inside the caves, and the bat colonies location. In general, the bat colonies are located at the medium or low radon concentration levels zones. (author)

  1. Determination of the emanation coefficient of radon for the South Karelia soil

    Energy Technology Data Exchange (ETDEWEB)

    Filimonov, V V

    1975-01-01

    Measurements have been obtained for so-called 'reference' plots which are used for the calibration of airborne gamma-spectrometric instruments - in all about 200 spot observations, not counting the results of continuous survey taken while in motion. The gamma-spectrometric measurements were carried out taking into account as far as possible a number of disturbing factors, such as the fluctuations in soil moisture, atmospheric precipitation, variations in the atmospheric radon concentration due to the temperature inversions.

  2. Evaluation of Airborne MDF Dust Concentration in Furniture Factories

    Directory of Open Access Journals (Sweden)

    Renilson Luiz Teixeira

    2017-10-01

    Full Text Available ABSTRACT High concentrations of airborne dust are observed during the cutting of medium density fiberboard (MDF boards. This dust, at first considered just uncomfortable for workers, may be harmful to their health. The objective of this work was to evaluate the concentration of airborne dust during the cutting of medium density fiberboard (MDF. The experiment was developed in the MDF cutting sector of three furniture factories located in the city of Lavras/MG. The results showed that the mean concentrations of total dust suspended in these three furniture factories were above the tolerance limit set by the American Conference of Governmental Industrial Hygienists (ACGIH, giving evidence of a serious problem in these companies related to this type of risk agent.

  3. Radon as a groundwater tracer in Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Grolander, Sara

    2009-10-15

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  4. Significance of radioelement concentration measurements made by airborne gamma-ray spectrometry over the Canadian Shield

    International Nuclear Information System (INIS)

    Charbonneau, B.W.; Killeen, P.G.; Carson, J.M.; Cameron, G.W.; Richardson, K.A.

    1976-01-01

    Results of airborne gamma-ray spectrometer surveys conducted by the Geological Survey of Canada are presented as maps contoured in units of radioelement and concentration ratios. These contoured values represent the average surface concentrations of the radioelements over areas of the order of several square kilometres. The relationship between this ''average surface concentration'' and the radioelement concentration in bedrock underlying the area depends on: (1) the percentage of outcrop; (2) the relation between overburden and bedrock radioelement concentration; (3) percentage of marshland or surface water in the area; (4) soil moisture; and (5) density of vegetation. More than 2500 portable gamma-ray spectrometer analyses of outcrop and overburden have been made in the Bancroft, Elliot Lake and Fort Smith areas of the Canadian Precambrian Shield. In the areas examined, the radioelement concentrations in glacial drift reflect the concentrations in the underlying bedrock. Rocks with near-crustal average contents of thorium, uranium and potassium are overlain by glacial drift having approximately the same concentrations. As the concentration in bedrock increases, the concentration in the local overburden also increases, but not to the same extent. In addition, in-situ gamma-ray spectrometry measurements were made at almost 1000 stations within the area of airborne surveys near Mont Laurier and Elliot Lake. These ground measurements were compared with the airborne measurements by averaging the values for all those ground stations located in the areas between each contour level on airborne maps. Radioelement concentrations in bedrock are considerably higher than corresponding airborne measurements, and this difference between bedrock and airborne values increases at higher radioelement concentrations. Radioelement concentrations in glacial drift are only slightly higher than airborne contour values for the same area. Airborne contour maps of the radioelement ratios

  5. Radon concentration studies in houses on the territory of the former German Democratic Republic

    International Nuclear Information System (INIS)

    Lehmann, R.

    1993-01-01

    In cooperation with the Federal Institute of Water, Soil and Air Hygiene, studies have been made since March 1990 in mining centers in the South of the former GDR territory on radon concentration in as many differently used houses as possible, predominantly in dwelling houses, but also in plant buildings, schools, kindergartens, recreation homes, etc. Under this program, measurements were performed until October 1990 in the cities of Schneeberg, Johanngeorgenstadt and Ronneburg and in the municipality of Schlema. The results obtained from this radon screening covering almost the whole affected area, qualitatively correspond to those obtained from small random samples taken under a regional measuring program performed in the respective muncipalities. A summary presentation is given of the range of radon concentration in houses to be expected in East Germany, relating it to geologically different areas in accordance with the present state of knowledge. (orig./DG) [de

  6. Relevance of air conditioning for 222Radon concentration in shops of the Savona Province, Italy

    International Nuclear Information System (INIS)

    Panatto, Donatella; Ferrari, Paola; Lai, Piero; Gallelli, Giovanni

    2006-01-01

    Radon ( 222 Rn) concentration was evaluated in shops of the Savona Province, Italy, between summer 2002 and winter 2002-2003. The main characteristics of each shops were recorded through a questionnaire investigating the ventilation rate and factors related to 222 Rn precursors in the soil and the construction materials. The main variables that were related to radon concentration were the following: age of the building, level of the shop above ground, season of the year, wind exposure, active windows, and type of heating system. Shops equipped with individual air heating/conditioning systems exhibited radon concentrations that were three times higher than those of shops heated by centralized furnaces. Our data indicate that the level of pollution in the shops was of medium level, with an expected low impact on the salespersons' health. Only in wintertime, the action level of 200 Bq m -3 for the confined environment was reached in 10 shops equipped with individual air heating/conditioning systems

  7. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  8. Measurement of radon concentration in air employing Lucas chamber; Pomiar koncentracji radonu za pomoca komory Lucasa

    Energy Technology Data Exchange (ETDEWEB)

    Machaj, B.

    1997-12-31

    The results of investigations aimed to determine the main features of radon concentration gauge in air, employing 0.17 L Lucas chamber, and air sample forced by an air pump are presented. For two hour sampling and measuring cycle time the dynamic error in the worst case (first read out) equals 5 % relative to the step jump of radon concentration. This is due to the increase of activity of the decay products in the chamber. It was observed that the short lived radon decay products (Po-218, Pb-214, Bi-214) are depositing on the walls of the chamber and they are not removed by flushing the chamber with air. (author). 4 refs, 19 figs, 2 tabs.

  9. Measurement of airborne radon daughters - a Bayesian approach

    International Nuclear Information System (INIS)

    Groer, P.G.; Lo, Y.

    1997-01-01

    The standard mathematical treatment of the build-up and decay of airborne radionuclides on a filter paper uses the solutions of the so-called Bateman equations adapted to the sampling process. These equations can be interpreted as differential equations for the expectation of an underlying stochastic process, which describes the random fluctuations in the accumulation and decay of the sampled radioactive atoms. The probability distribution for the number of 218 Po, 214 Pb and 214 Bi atoms, accumulated after sampling time t, is the product of three Poisson distributions. It is shown that the distribution of the number of counts, registered by a detector with efficiency ε during a counting period T after the end of sampling, is also the product of three Poisson distributions. Its mean is dependent on ε, t, T, flow rate, and N A 0 , N B 0 and N C 0 , the number of 218 Po, 214 Pb and 214 Bi atoms per unit volume. This joint Poisson distribution was used to construct the likelihood given the observed number of counts. Using Bayes' Theorem posterior densities were obtained for N A 0 , N B 0 and N C 0 . These densities characterise the remaining uncertainty about the unknown airborne concentrations of 218 Po, 214 Pb and 214 Bi atoms. (author)

  10. Determination of radon concentration in water using RAD7 with RAD H2O accessories

    International Nuclear Information System (INIS)

    Malik, M. F. I.; Rabaiee, N. A.; Jaafar, M. S.

    2015-01-01

    In the last decade, the radon issue has become one of the major problems of radiation protection. Radon exposure occurs when using water for showering, washing dishes, cooking and drinking water. RAD7 and Rad H20 accessories were used in order to measure radon concentration in water sample. In this study, four types of water were concerns which are reverse osmosis (drinking water), mineral water, tap water and well water. Reverse osmosis (drinking water) and mineral water were bought from the nearest supermarket while tap water and well water were taken from selected areas of Pulau Pinang and Kedah. Total 20 samples were taken with 5 samples for each type of water. The measured radon concentration ranged from 2.9±2.9 to 79.5±17 pCi/L, 2.9±2.9 to 67.8±16 pCi/L, 15.97±7 to 144.25±24 pCi/L and 374.89±37 to 6409.03±130 pCi/L in reverse osmosis (drinking water), mineral water, tap water and well water. Well water has the highest radon compared to others. It was due to their geological element such as granite. Results for all types of water are presented and compared with maximum contamination limit (MCL) recommended by United State Environmental Protection Agency (USEPA) which is 300pCi/L. Reverse osmosis water, mineral water and tap water were fall below MCL. However, well water was exceeded maximum level that was recommended. Thus, these findings were suggested that an action should be taken to reduce radon concentration level in well water as well as reduce a health risk towards the public

  11. Results of the first 5 years of a study on year-to-year variations of radon concentration in Italian dwellings

    International Nuclear Information System (INIS)

    Bochicchio, F.; Ampollini, M.; Antignani, S.; Bruni, B.; Quarto, M.; Venoso, G.

    2009-01-01

    Radon concentration in air is subject to significant variations at different time scales, owing to several factors. In general, the shorter the time period considered, the larger the variations in radon concentration, e.g., day-to-day variations are usually higher than month-to-month variations. An average over 12 consecutive months is generally considered the best estimate of the long-term average radon concentration. Due to practical reasons, however, very few data are available on year-to-year variations. Year-to-year variations can have quite a relevant impact on radon policies and on the assessment of health risks from exposures to radon. Therefore, a project was started in 1996 aimed to evaluate year-to-year variations in a sample of dwellings. Systematic radon measurements have been made with LR 115 based radon detectors (closed type) in the living room and one bedroom of a sample of dwellings in Rome (Italy). The analysis of the results of the first five consecutive years of measurements, regarding the 76 dwellings included in the final analysis, showed relatively low year-to-year variations, with a median coefficient of variation of 14% (range 3%-42%), smaller than that observed in studies from other European countries. Therefore, in the analyzed sample, 12-month measurements can be considered a good estimate of the average radon concentration, at least within a 5-year period. This is quite important for radon regulations and policies, e.g. annual measurements could be recommended and repetition of radon measurements could not be necessary within periods of 5 years. Moreover, the impact of the observed year-to-year variations on the lung cancer risk estimated in the Italian epidemiological study is expected to be not high, if variations on periods up to about 30 years can be assumed similar to those observed in this study.

  12. Modeling of indoor radon

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1990-01-01

    This paper reports on models for radon, which are developed not only to describe the behavior of radon and daughters since the moment that radon is created in natural sources by the alpha decay of 226 Ra up to the point that doses to humans are estimated based on the inhalation of radon and its progeny. The objective of a model should be determinant in defining the model structure and boundaries. Modeling indoors radon is particularly useful when the 226 Ra concentration in building materials and soils can be known before a house will be built with such 226 Ra bearing materials and over 226 Ra rich soils. The reported concentrations of 226 Ra in building materials range from 0.3 Bq · kg -1 in wood to about 2.6 x 10 3 Bq · kg -1 in aerated concrete based on alum shale. 30 In addition, when a house is built on a soil containing a high 226 Ra concentration, radon exhalation from the soil contributes to increase radon concentration indoors. The reported radon exhalation from soils range from 3.4 Bq · m -2 · s -1 in latosolic soil from Osaka, Japan to about 53 mBq · m -2 · s -1 in chernozemic soil from Illinois

  13. A nationwide radon concentration survey project in Japan. Outdoor and workplaces

    International Nuclear Information System (INIS)

    Oikawa, S.; Kanno, N.; Ohashi, N.; Abukawa, J.

    2003-01-01

    Nationwide survey for outdoor and workplace radon ( 222 Rn) concentration in Japan were carried out to evaluate the effective dose to the general public due to 222 Rn and its progeny. The 222 Rn concentration was measured by using passive-type radon/thoron discriminative monitor equipped with polycarbonate films. Concentration of 222 Rn was calculated from etch pit counts appeared on the polycarbonate film after chemical and electrochemical etching. For outdoor 222 Rn survey, the monitors were installed at about 700 points throughout Japan on every quarters of the fiscal year 1997 to 1999. The mean concentration of outdoor 222 Rn concentration was 6.1 Bq m -3 from the results of 696 measurement points. Seasonal variation of outdoor 222 Rn was found to be minimal in July to September, and maximal in October to December. For workplace 222 Rn survey, the monitors were installed at about 700 points in four categories (office, factory, school and hospital) on every quarters of the fiscal year 2000 to 2002. Nationwide mean 222 Rn concentration in workplaces was found to be 22.7 Bq m -3 for 2000 and 20.7 Bq m -3 for 2001, respectively. Seasonal variation of 222 Rn concentration measured at office, factory, school and hospital were also found to be minimal in July to September, and maximal in October to December. (author)

  14. Radon as a groundwater tracer in Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Grolander, Sara

    2009-10-01

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  15. Investigation of radon level in Chongqing

    International Nuclear Information System (INIS)

    Pan Chunzhen; Liu Jialie; Du Hengyan; Wang Ling; Li Yiwei

    2009-01-01

    Contents of radon in air in the urban district, building fields,diggings and hotel in Chongqing were investigated. Result shows that the mean concentration of radon is 10.8 Bq/m 3 in air in the urban district, and the mean concentration of radon is 1193 Bq/m 3 in soils on building fields. Radon level is obviously different in each of diggings, with the highest being in fluorite mine and the second in plumbum and zinc mine. The statistical mean value of radon concentration of 10 typles of diggings investigated is 65.2 Bq/m 3 , while the mean concentration of radon in fluorite mine is 369 Bq/m 3 , which is 35 times higher than in the urban area. The mean concentration of radon is 32.9 Bq/m 3 in eight hotels. (authors)

  16. Radon concentration in drinking water and supplementary exposure in Baita-Stei mining area, Bihor county (Romania).

    Science.gov (United States)

    Moldovan, Mircea; Nita, Dan Constantin; Cucos-Dinu, Alexandra; Dicu, Tiberius; Bican-Brisan, Nicoleta; Cosma, Constantin

    2014-03-01

    The radon concentration was measured in the drinking water of public water supply and private wells located in the mining area of BăiŢa-Ştei, Bihor County, Romania. The measurements were performed using the LUK-VR system based on radon gas measurement with Lucas cell. The results show that the radon concentrations are within the range of 1.9-134.3 kBq m(-3) with an average value of 35.5 kBq m(-3) for well water, 18.5 kBq m(-3) for spring water and 6.9 kBq m(-3) for tap water. Comparing with previous data from the whole of Transylvania, the average value is two times higher, proving this zone to be a radon-prone area. From the results of this study the effective dose to the population is between 4.78 and 338.43 µSv y(-1). These doses are within the recommended limits of the world organisations.

  17. Indoor radon concentration data: Its geographic and geologic distribution, an example from the Capital District, NY

    International Nuclear Information System (INIS)

    Thomas, J.J.; Overeynder, H.M.; Thomas, B.R.

    1995-01-01

    Most studies of the geographic distribution of indoor radon levels are plotted by county or ZIP code. This method is used for the radon potential maps produced by the U.S. Environmental Protection Agency (EPA) and the New York State Department of Health (NYSDOH). The basis for the mapping is the mean or median indoor radon count for all the data provided by NYSDOH within each geographic area. While testing the indoor radon analyses provided to the authors by CMT Independent Laboratories, we discovered data that deviated markedly from the EPA and NYSDOH means for the Capital District of New York (Albany and surrounding counties). Their screening indoor radon average concentrations in pCi/L, indicate low potential for Schenectady (3.0), Saratoga (3.2), and Albany (3.7) counties; and moderate potential for Rensselaer (6.4) and Columbia (7.0) counties. Our database of over 3,000 analyses contains over 800 records of indoor radon counts above 4 pCi/L (14-47% of each county's analyses), many high enough to be rated as a serious health hazard. In order to obtain greater precision of information, the authors plotted their indoor radon data by street address using MapInfo, a geographic Information System (GIS), and StreetInfo, MapInfo's TIGER address database. We compared the geographic distribution of our data to both the Bedrock Geology and Surficial Geology Maps of New York State. The results show a striking relationship of radon concentrations to bedrock, faults and permeability of surficial material. Data being compiled and mapped by street address by the NYSDOH in Erie County in western New York, confirm our results

  18. Radon concentration assessment in water sources of public drinking of Covilhã's county, Portugal

    Directory of Open Access Journals (Sweden)

    M. Inácio

    2017-04-01

    Radon concentration measurements were performed on thirty three samples collected from water wells at different depths and types of aquifers, at Covilhã's County, Portugal with the radon gas analyser DURRIDGE RAD7. Twenty three, of the total of water samples collected, gave, values over 100 Bq/L, being that 1690 Bq/L was the highest measured value.

  19. A compact multiparameter acquisition system for radon concentration studies

    Science.gov (United States)

    Pugliese; Baiano; Boiano; D'Onofrio; Roca; Sabbarese; Vollaro

    2000-07-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system.

  20. A compact multiparameter acquisition system for radon concentration studies

    International Nuclear Information System (INIS)

    Pugliese, M.; Baiano, G.; Boiano, A.; D'Onofrio, A.; Roca, V.; Sabbarese, C.; Vollaro, P.

    2000-01-01

    A compact device suitable to acquire and display, at the same time, radon concentrations in a given atmosphere, and the environmental parameters characterising the atmosphere, is presented and described. It consists of two main blocks: (i) a detection section including a set of sensors for measuring pressure, humidity and temperature, and a set of silicon surface barrier detectors mounted in electrostatic cells collecting the ionised radon daughters; (ii) a single NIM module featuring an eight channel 12 bit ADC and the linear electronics to shape the signals from the silicon detectors. The system is controlled by a computer via a RS232 port. The software, implemented in Visual Basic, allows to display the energy distribution of the pulses coming from the alpha detectors and to initialise and control all phases of the acquisition. The results of preliminary tests show the high reliability of the system