WorldWideScience

Sample records for radius fracture reduction

  1. HAEMATOMA BLOCK- AN EFFECTIVE ALTERNATIVE TO GENERAL ANAESTHESIA FOR REDUCTION OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Prabhati Rani Mishra

    2016-12-01

    Full Text Available BACKGROUND Most common fracture in elderly patients is distal radius fracture. The most common method of management is closed reduction and immobilisation. The aim of the study is to compare the analgesic effects of haematoma block and general anaesthesia for closed reduction of distal fracture of radius. MATERIALS AND METHODS A prospective randomised controlled study was carried out among 100 patients of age group between 15-70 years of either sex who had fracture distal radius between 2015-2016. The patients having multiple fractures, pathological fractures or suffering from any organic diseases were excluded from the study. After taking informed written consent, the patients were randomised into two equal groups. In group A, reduction of fracture was done following administration of IV propofol and in group B after infiltration with 2% lignocaine into fracture haematoma site. Pain score was compared by VAS before, during and after manipulation in both the groups. Time taken from presentation at emergency department to reduction and discharge from hospital was also compared. Statistical analysis was done by applying SPSS software. RESULTS 100 patients of mean age 42.5 years, male: female 43:57 with fracture distal radius were studied. Mean time from admission to fracture reduction in group A was 2.64±0.93 hours and in group B 0.90±0.45 hours (P=0.0001. Discharge time from hospital after reduction of fracture in group A was 4.24±0.94 hours and in group B 0.75±0.2 hours (P=0.0001. VAS during reduction in group A was 0 and in group B 0.98±0.8 (P=0.0001. 10 minutes after reduction VAS in group A was 2.28±0.24 and group B 0.72±0.45 (P=0.0001. CONCLUSION For closed reduction of distal radius fracture, haematoma block with lignocaine is safe and effective alternative to intravenous general anaesthesia with propofol.

  2. Radius crossover sign: an indication of malreduced radius shaft greenstick fractures.

    Science.gov (United States)

    Wright, Patrick B; Crepeau, Allison E; Herrera-Soto, José A; Price, Charles T

    2012-06-01

    Radius shaft greenstick fractures in children can be a challenging injury to treat because angulation and rotational alignment are difficult to assess. In this report, we describe a simple method for analyzing the deformity and identifying rotational and angular malalignment. This technique involves analyzing the forearm radiographs as 2 segments, proximal and distal, and assuring that the rotational position of each matches the other. We present 3 cases of proximal radius greenstick fractures in malalignment to demonstrate the radius crossover sign. Identifying the radius crossover sign, and proceeding with further closed reduction may prevent deformity that could otherwise result in a significant loss of forearm motion. Level V.

  3. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  4. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  5. Nerve Stimulator Guided Axillary Block in Painless Reduction of Distal Radius Fractures; a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Hossein Alimohammadi

    2013-12-01

    Full Text Available Introduction: Given the high prevalence of upper extremity fractures and increasing need to perform painless reduction in the emergency departments, the use of analgesic methods with fewer complications and more satisfaction appears to be essential. The aim of this study is comparison the nerve stimulator guided axillary block (NSAB with intravenous sedation in induction of analgesia for painless reduction of distal radius fractures. Methods: In the present randomized clinical trial, 60 patients (18-70 years of age suffered from distal radius fractures, were divided into two equal groups. One group received axillary nerve block by nerve stimulator guidance and the other procedural sedation and analgesia (PSA using midazolam/fentanyl. Onset of analgesia, duration of analgesic effect, total procedure time and pain scores were recorded using visual analogue scale (VAS and the outcomes were compared. Chi-squared and student t test were performed to evaluate differences between two groups. Results: Sixty patients were randomly divided into two groups (83.3% male. The mean age of patients was 31 ±0.7 years. While the onset of analgesia was significantly longer in the NSAB group, the mean total time of procedure was shorter than PSA (p<0.001. The NSAB group needed a shorter post-operative observation time (P<0.001. Both groups experienced equal pain relief before, during and after procedure (p>0.05. Conclusion: It seems that shorter post-operative monitoring time and consequently lesser total time of procedure, make nerve stimulator guided axillary block as an appropriate alternative for procedural sedation and analgesia in painless reduction of distal radius fractures in emergency department. 

  6. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    International Nuclear Information System (INIS)

    Jaremko, J.L.; Lambert, R.G.W.; Rowe, B.H.; Johnson, J.A.; Majumdar, S.R.

    2007-01-01

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal (∼6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 ± 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary

  7. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, J.L. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Lambert, R.G.W. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Rowe, B.H. [Department of Emergency Medicine, University of Alberta, Edmonton, Alberta (Canada); Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Johnson, J.A. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada); Majumdar, S.R. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada) and Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada)]. E-mail: me2.majumdar@ualberta.ca

    2007-01-15

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal ({approx}6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 {+-} 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary.

  8. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    Science.gov (United States)

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  9. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  10. Two peg spade plate for distal radius fractures A novel technique

    Directory of Open Access Journals (Sweden)

    Sharad M Hardikar

    2015-01-01

    Conclusions: The two peg volar spade plate provides a stable subchondral support in comminuted intraarticular fractures and maintains reduction in osteoporotic fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and to prevent development of wrist stiffness.

  11. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  12. A PROSPECTIVE STUDY OF CLINICAL OUTCOME AFTER USING LIGAMENTOTAXIS IN MANAGEMENT OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Chandrashekhar V. Mudgal

    2017-04-01

    Full Text Available BACKGROUND A study was done to evaluate the effect of the ligamentotaxis in the management of intraarticular fractures of the distal radius. MATERIALS AND METHODS 34 patients were studied prospectively between March 2014 and February 2016. All patients had intraarticular fracture of distal end of radius and all were treated with ligamentotaxis after closed reduction with fluoroscopic guidance. The follow-up period was 12 months. At the time of surgery, the mean age was 45.29 years. RESULTS In all fracture cases, the mean of fracture union was 5.8 weeks. During the final follow-up, the mean range of motion was 55.30 in flexion, 56.60 in extension, 21.0 in ulnar deviation, 9.00 in radial deviation, 70.30 in pronation and 67.10 in supination. According to the scoring system of Gartland and Werley, the clinical and functional outcomes showed that 15 patients (44.1% had excellent results, 14 (41.1% had good results, 3 (8.8% had fair results and 2 (5.8% had poor results. CONCLUSION Closed reduction under fluoroscopic image guidance and the ligamentotaxis is useful and effective in the treatment of intraarticular fractures of the distal radius.

  13. Classification and treatment of distal radius fractures: a survey among orthopaedic trauma surgeons and residents

    NARCIS (Netherlands)

    M.A.M. Mulders (Marjolein A. M.); D. Rikli; J.C. Goslings (Carel); N.W.L. Schep (Niels)

    2017-01-01

    textabstractPurpose: Classification, the definition of an acceptable reduction and indications for surgery in distal radius fracturemanagement are still subject of debate. The purpose of this study was to characterise current distal radius fracture management in Europe. Methods: During the European

  14. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  15. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID): protocol for a randomized clinical multi-center trial.

    Science.gov (United States)

    Bartl, Christoph; Stengel, Dirk; Bruckner, Thomas; Rossion, Inga; Luntz, Steffen; Seiler, Christoph; Gebhard, Florian

    2011-03-22

    Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF) with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation.Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius) is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool.The primary objective is to determine differences in the Short Form 36 (SF-36) Physical Component Score (PCS) between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH) instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery), as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture involves a central statistical unit, an independent

  16. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    Science.gov (United States)

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  17. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    Science.gov (United States)

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the

  18. Factors associated with infection following open distal radius fractures.

    Science.gov (United States)

    Glueck, Dane A; Charoglu, Constantine P; Lawton, Jeffrey N

    2009-09-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone fractures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated with these infections. We hypothesize that contamination, rather than absolute wound size, is the best predictor of infection associated with open distal radius fractures. A review by CPT code yielded 42 patients with open distal radius fractures between 1997 and 2002 treated at a level one trauma center. Medical records and radiographic follow-up were reviewed to assess the time to irrigation and debridement, the number of debridements in initial treatment period, the method of operative stabilization, the Gustilo and Anderson type of fracture, the Swanson type of fracture, and description of wound contamination. Forty-two patients were followed up for an average of 15 months (range 4 to 68 months). Twenty-four fractures were classified as Gustilo and Anderson type I, ten were type II, and eight were type III, 30 were Swanson type I, and 12 were Swanson type II. Five of the 42 fractures were considered contaminated. Two were exposed to fecal contamination. The others were contaminated with tar, dirt/grass, and gravel, respectively. Three of 42 (7%) fractures developed infections. All three infected cases received a single irrigation and debridement. Two of five contaminated fractures (40%) developed a polymicrobial infection. Both were exposed to fecal contamination and, therefore, considered Swanson type II fractures. They were classified as Gustilo and Anderson type II and IIIB based solely upon the size of the wound. Both required multiple debridements and eventually wrist

  19. [Roof folding and rotary pushing for the treatment of back to back fractures of distal radius and ulna in children].

    Science.gov (United States)

    Xu, Ping; Dong, Xiao-jun; Lu, Zhou-tong; Wang, Gongjun; Zhang, Han-qing; Chen, Xuan-ning; Li, Dong

    2015-09-01

    To evaluate the technique and the clinical effect of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back". From January 2012 to February 2014,38 children with distal radius and ulna fracture of "back to back" were treated by using the technique of folding roof and rotary pushing to reset and splint fixation including 23 males and 15 females with an average age of 9.5 years old ranging from 6 to 14 years old. Injury time was from 45 min to 3 days (averaged 1.3 days). All cases was unilateral closed fracture without symptoms of nerve injury occurred. The wrist joint anteroposterior and lateral radiographs showed double fracture of radius and ulna, and the broken end of radius was typical "back to back" displacement. The quality of reduction was assessed according to Dienst recommendation on the combination of Aro measurement, and the therapeutic effect was evaluated using standard of Anderson function. All patients were followed up from 3 to 13 months with an average of 6 months. There were no iatrogenic nerve injury. Thirty cases were treated successfully for the first time, 8 cases were again reset successfully; 28 cases were anatomical reduction, 7 cases were near anatomic reduction, 3 cases were functional reduction. At the second day 7 cases with hand and finger swelling appeared in multiple reset patients. Quality results of reduction were excellent in 33 cases, good in 5 cases. According to the standard of Anderson function evaluation, 35 cases were excellent, 3 cases were good. All fractures were healed with of deformity of wrist. Using the technique of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back" is very successful, the patient's limb function recovered well, the whole operation process is simple.

  20. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID: protocol for a randomized clinical multi-center trial

    Directory of Open Access Journals (Sweden)

    Seiler Christoph

    2011-03-01

    Full Text Available Abstract Background Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation. Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. Methods/Design ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool. The primary objective is to determine differences in the Short Form 36 (SF-36 Physical Component Score (PCS between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery, as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture

  1. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  2. Pathologic fracture of the distal radius in a 25-year-old patient with a large unicameral bone cyst.

    Science.gov (United States)

    Massen, Felix; Baumbach, Sebastian; Volkmer, Elias; Mutschler, Wolf; Grote, Stefan

    2014-06-13

    Distal radius fractures (DRF) are often referred to as osteoporosis indicator fractures as their incidence increases from age 45. In the group of young adults, distal radius fractures normally result from high-energy trauma. Wrist fractures in young patients without adequate trauma thus raise suspicion of a pathologic fracture. In this report we present the case of a fractured unicameral bone cyst (UBC) at the distal radius in a young adult.To the author's best knowledge, this is the first detailed report in an UBC at the distal radius causing a pathologic DRF in an adult patient. A 25-year-old otherwise healthy male presented to our Emergency Department after a simple fall on his right outstretched hand. Extended diagnostics revealed a pathologic, dorsally displaced, intra-articular distal radius fracture secondary to a unicameral bone cyst occupying almost the whole metaphysis of the distal radius. To stabilize the fracture, a combined dorsal and volar approach was used for open reduction and internal fixation. A tissue specimen for histopathological examination was gathered and the lesion was filled with an autologous bone graft harvested from the ipsilateral femur using a reamer-irrigator-aspirator (RIA) system. Following one revision surgery due to an intra-articular step-off, the patient recovered without further complications. Pathologic fractures in young patients caused by unicameral bone cysts require extended diagnostics and adequate treatment. A single step surgical treatment is reasonable if fracture and bone cyst are treated appropriately. Arthroscopically assisted fracture repair may be considered in intra-articular fractures or whenever co-pathologies of the carpus are suspected.

  3. MRI of fractures of the distal radius: comparison with conventional radiographs

    International Nuclear Information System (INIS)

    Spence, L.D.; Eustace, S.

    1998-01-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.)

  4. MRI of fractures of the distal radius: comparison with conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Spence, L.D.; Eustace, S. [Medical Center, Boston, MA (United States). Dept. of Radiol.; Savenor, A.; Nwachuku, I.; Tilsley, J. [Department of Orthopedics, Boston Medical Center, Boston, MA 02118 (United States)

    1998-05-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.) With 5 figs., 16 refs.

  5. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  6. Assessment of "YouTube" Content for Distal Radius Fracture Immobilization.

    Science.gov (United States)

    Addar, Abdullah; Marwan, Yousef; Algarni, Nizar; Berry, Gregory

    Distal radius fractures (DRFs) are the most common orthopedic fractures, with >70% of cases treated by closed immobilization using a short arm cast or a sugar tong splint. However, inadequate immobilization is a risk factor for loss of reduction requiring repeat reduction or surgical treatment. Therefore, education of clinical skills for appropriate immobilization of DRFs is important. With the increasing use of web-based information by medical learners, our aim was to assess the quality and quantity of videos regarding closed immobilization of DRFs on YouTube. Retrospective review of YouTube videos on distal radius fracture immobilization using specific search terms. Identified videos were analyzed for their educational value, quality of the technical skill demonstrated, and overall metrics. Educational value was scored on a 5-point scale, with "1" indicative of low quality and "5" of high quality. Not applicable. Among the 68,366 videos identified, 16 met our inclusion criteria of being in English; performed by a health care professional or institution; and with casting being the major theme of the educational information provided. Of these 16 videos, 6 had an educational value score of 4 or 5, with the remaining 10 having a score ≤3. Although immobilization was demonstrated by cast technician specialized in orthopedics, skills were also performed by orthopedic attendants, urgent care physicians, orthopedic residents, and nurse practitioners. The credentials of the performer in 3 videos were not identified. There is a need to promote high-quality educational videos produced by established medical school faculty members on open, web-based, portals. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. Does formal education and training of staff reduce the operation rate for fractures of the distal radius?

    Science.gov (United States)

    McDonald, Kyle; Murphy, Lynn; Gallagher, Brendan; Eames, Niall

    2013-12-01

    Fractures of the distal radius are one of the most common extremity fractures, and operation rates are increasing. Staff within our unit felt that formal teaching, particularly of new medical staff, with regards to fracture reduction and appropriate cast application could result in a reduction in operation rates. Retrospective data was extracted from FORD (Fracture Outcome and Research Database), including: number of fractures, number of fractures undergoing ORIF, fracture configuration, patient demographics, and mechanism of injury. All patients undergoing ORIF had their radiographs assessed by two separate reviewers. Information regarding adequate fracture reduction, adequate cast application (using Gap Index), and appropriate plaster cast moulding was recorded. Formal teaching was then given to the next group of medical staff rotating through the unit, and the same data was collected prospectively for that six-month period. Exclusion criteria included bilateral injuries, and polytrauma patients. A total of 1623 distal radial fractures were treated in our unit over the 12-month period, with 71 undergoing ORIF in the first 6 months and 39 in the second 6 months, this was statistically significant (p = 0.0009). Our study found that formal teaching and education significantly reduced the operation rate for distal radial fractures. This effect was most significant for extra-articular, dorsally angulated fractures of the distal radius. Our study proves that just 1 h of basic training at the beginning of an attachment can have significant benefits to both the unit and, more importantly, the patients. Copyright © 2013 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  8. Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator.

    Science.gov (United States)

    Tyllianakis, Minos; Mylonas, Spyros; Saridis, Alkis; Kallivokas, Alkiviadis; Kouzelis, Antonis; Megas, Panagiotis

    2010-03-01

    Unstable distal radius fractures remain a challenge for the treating orthopaedic surgeon. We present a retrospective follow-up study (mean follow-up 12.5 months) of 20 patients with 21 unstable distal radius fractures that were reduced in a closed manner and stabilized with a nonbridging Ilizarov external fixator. Subsequent insertion of olive wires for interfragmentary compression was performed in cases with intra-articular fractures. According to the overall evaluation proposed by Gartland and Werley scoring system 12 wrists were classified as excellent, 6 as good, 2 as fair and 1 as poor. Grade II pin-tract infection in distal fracture fragment was detected in 3 wires from a total of 78 (3.8%) and in 4 half pins out of a total of 9 (44.4%). Pronation was the most frequently impaired movement. This was restricted in 4 patients (19%) in whom a radioulnar transfixing wire was applied. Symptoms of irritation of superficial sensory branch of the radial nerve occurred in 3 patients with an olive wire applied in a closed manner in the distal fragment. Ilizarov method yields functional results comparable to that of other methods whilst it avoids wrist immobilization, open reduction and reoperation for implant removal. The method is associated with a low rate of major complication and satisfactory functional outcome. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Ipsilateral simultaneous fracture of the trochlea involving the lateral end clavicle and distal end radius: a rare combination and a unique mechanism of injury

    Directory of Open Access Journals (Sweden)

    Gupta RK

    2014-07-01

    Full Text Available 【Abstract】Isolated trochlea fracture in adults is a rare surgical entity as compared to its capitellar counterpart. It has been only mentioned sporadically in the literature as case reports. Fracture of the trochlea is accompanied by other elbow injuries like elbow dislocation, capitellum fracture, ulnar fracture and extraarticular condylar fracture. Here we report a unique case of isolated displaced trochlea fracture associated with fractures of the lateral end clavicle and the distal end radius. We propose a unique mechanism for this rare combination of injuries: typical triad of injury, i.e. fracture of the distal end radius with trochlea and fracture of the lateral end of the clavicle. Nonoperative treatment is recommended for undisplaced humeral trochlea fractures; but for displaced ones, anatomical reduction and internal fixation are essential to maintain the congruous trochleacoronoid articulation and hence to maintain the intrinsic stability of the elbow. Key words: Isolated trochlea fracture; Clavicle; Radius fractures

  10. [Distal radius fractures--retrospective quality control after conservative and operative therapy].

    Science.gov (United States)

    Sommer, C; Brendebach, L; Meier, R; Leutenegger, A

    2001-01-01

    The distal radius fracture is the most frequent fracture in the adult patient. The wide spectrum of different types of fracture and the coexisting factors make the choice for the optimal treatment difficult. As an interne quality control we retrospectively evaluated all patients with distal radius fractures treated in 1995 at our institution. The study included 69 adult patients with 71 distal radius fractures. After on average 26 months 58 patients with 59 fractures were clinically and radiologically evaluated. The patients were asked to give supplementary information about their follow-up treatment as well as any remaining physical difficulties and limitations in the daily life. All x-rays of the broken radius were carefully analysed and compared with the opposite side. The final results were evaluated according to the "Demerit Point System". Patients were treated with five different therapeutical methods. 76.3% of the patients showed a very good/good final result. In 56.7% of the cases secondary fracture dislocation occurred; the dislocation-rate of fractures treated with percutaneous k-wires was 93.3%! A clear correlation between secondary displacement and final results was found. A main factor for an optimal outcome is the anatomic restoration of length and axis of the distal radius as well as of joint congruency, also moderate angular deformities are well tolerated. Our collective showed an unexpected high rate of secondary displacement, especially in the k-wire group. The reasons for this unsatisfactory event are manifold: too optimistic indication, insufficient follow-up examination in the first four to six weeks, inconsequent change to a more stable fixation method in case of a secondary dislocation. The results of this retrospective evaluation had a major impact on our concept of treatment. The dorso-radial double-plate technique combined with bone graft will be more used in the future especially in younger patients. The new standardised concept is the

  11. Factors Associated with Infection Following Open Distal Radius Fractures

    OpenAIRE

    Glueck, Dane A.; Charoglu, Constantine P.; Lawton, Jeffrey N.

    2009-01-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone factures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated wi...

  12. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    Science.gov (United States)

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  13. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach.

    Science.gov (United States)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-07-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  14. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-01-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopy-guided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of ≥2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  15. Immobilisation of extra-articular distal radius fractures (Colles type) in dorsiflexion. The functional and anatomical outcome.

    Science.gov (United States)

    Baruah, Ranjit Kr; Islam, Mohibul; Haque, Russel

    2015-09-01

    Cast immobilisation after successful closed reduction is a standard treatment for displaced extra-articular fractures of lower end radius. The position of the wrist during immobilisation is controversial. Immobilisation in dorsiflexion prevents redisplacement after closed reduction. Our aim is to determine the effectiveness of immobilization of wrist in dorsiflexion in such cases and evaluate anatomical and functional outcome. Study included 54 patients, above 19 years of age with closed extra-articular fractures of lower end radius treated conservatively with below elbow cast application. The wrist was maintained in 15° of dorsiflexion during plaster immobilisation. At 24 weeks, functional results were evaluated with subjective symptoms and objective signs, as per modified Demerit Point Score System. Anatomical result was evaluated based on the scheme devised by Lidstrom (1959) and modified by Sarmiento et al. (1980). 76% patients had Excellent to Good subjective symptoms. Out of 42 patients that had residual dorsal angulation of less than 10°, 37 had excellent to good functional outcome. 39 of the 43 patients who had loss of radial length less than 6 mm had excellent to good functional outcome. 40 out of 49 patients having loss of radial angulation less than 9° showed excellent to good functional outcome. Functional result was directly proportional to anatomical outcome. Cast immobilization of extra articular fractures of lower end radius with wrist in dorsiflexion prevents re-displacement of the fragments resulting in satisfactory anatomical & functional outcome.

  16. Non-operative treatment of displaced distal radius fractures leads to acceptable functional outcomes, however at the expense of 40% subsequent surgeries

    NARCIS (Netherlands)

    Mulders, M. A. M.; van Eerten, P. V.; Goslings, J. C.; Schep, N. W. L.

    2017-01-01

    Background: Although secondary displacement following closed reduction and plaster immobilisation is high, several guidelines still recommend non-operative treatment for displaced distal radius fractures with an adequate closed reduction. Purpose: The purpose of this study was to evaluate functional

  17. Relationship between plate removal and Soong grading following surgery for fractured distal radius

    NARCIS (Netherlands)

    Selles, Caroline A.; Reerds, Sam T. H.; Roukema, Gert; van der Vlies, Kees H.; Cleffken, Berry I.; Schep, Niels W. L.

    2018-01-01

    The aim of this study was to determine the relationship between volar plate removal and the Soong classification following fixation for fractured distal radius. In this retrospective cohort study, all consecutive patients who had volar plate fixation for a distal radius fracture in 2011-2015 were

  18. "Osteoporosis and orthopods" incidences of osteoporosis in distal radius fracture from low energy trauma.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-07-01

    Fracture of the distal radius from low energy trauma is a common presentation to orthopaedic trauma services. This fragility type fracture is associated with underlying osteoporosis. Osteoporosis is a \\'silent disease\\' where fragility fracture is a common presentation. Orthopaedic surgeons may be the only physician that these patients encounter. We found a high percentage of female patients who sustained a fragility fracture of the distal radius have an underlying osteoporosis. Further management of osteoporosis is important to prevent future fragility fractures.

  19. Risk Factors Associated With Survival to Hospital Discharge of 54 Horses With Fractures of the Radius.

    Science.gov (United States)

    Stewart, Suzanne; Richardson, Dean; Boston, Ray; Schaer, Thomas P

    2015-11-01

    To determine (1) survival to discharge of horses with radial fractures (excluding osteochondral fragmentation of the distal aspect of the radius and stress fractures); and (2) risk factors affecting survival to hospital discharge in conservative and surgically managed fractures. Case series. Horses (n = 54). Medical records (1990-June 2012) and radiographs of horses admitted with radial fracture were reviewed. Horses with osteochondral fragmentation of the distal aspect of the radius or stress fractures were excluded. Evaluated risk factors were age, fracture configuration, surgical repair method, surgical duration, hospitalization time, implant failure rate, and surgical site infection (SSI) rate. Of 54 horses, overall survival to discharge was 50%. Thirteen (24%) were euthanatized on admission because of (1) fracture severity; (2) presence of an open fracture; or (3) financial constraints. Fourteen (26%) horses with minimally displaced incomplete fractures were conservatively managed and 12 (86%) survived to discharge. Twenty-seven (50%) horses had surgical treatment by open reduction and internal fixation (ORIF) and 15 (56%) survived to hospital discharge. Open fractures were significantly more likely to develop SSI (P = .008), which also resulted in a 17-fold increase in implant failure (P horses with an open fracture did not survive to discharge. Outcome was also adversely affected by age (P 168 minutes (P fractures is good. Young horses have a good prognosis survival to discharge for ORIF, whereas ORIF in adult horses has a poor prognosis and SSI strongly correlates with catastrophic implant failure. © Copyright 2015 by The American College of Veterinary Surgeons.

  20. A STUDY ON FRACTURE FIXATION OF DISTAL END OF RADIUS BY PERCUTANEOUS PINNING

    Directory of Open Access Journals (Sweden)

    Kiran Kumar L

    2016-07-01

    Full Text Available BACKGROUND Various treatment modalities have been described for the treatment of distal radius fractures each with its own merits and demerits. Most of the work done with percutaneous pinning has shown a significant residual stiffness of the hand and wrist. Our technique involves percutaneous pinning of the fracture and immobilisation in neutral position of the wrist for. This study's aim was to examine the functional outcome of percutaneous K-wiring of these distal radius fractures with immobilisation in neutral position of the wrist. METHODS A prospective study conducted on thirty adult patients with distal radial fractures treated at Department of Orthopaedics, Rangaraya Medical college, Kakinada between October 2013 to September 2015. RADIOGRAPHIC EXAMINATION Standard radiographs in PA and lateral views were taken for confirmation of the diagnosis and also to know the type of fracture. Oblique views were also taken in a few patients who had complex comminuted fractures. The fracture fragments were analysed and involvement of radiocarpal and distal radioulnar joints were assessed and classified according to the Frykman classification. Of the cases, 6(20% of the fractures were type I, 2(6.6% of type II, 3(10% of type III, 6(20% of type IV, 8(26.6% of type V, 5(16.6% of type VI, no cases of type VII and VIII.SURGICAL PROCEDURE The procedures were performed under regional anaesthesia in all cases. After sterile preparation and draping, fracture is reduced by traction and the reduction was evaluated fluoroscopically. A 1.5 cm incision given longitudinally (if needed beginning at the radial styloid and proceeds proximally across to the medial metaphysis and diaphysis. At least two pins (1.6 mm Kirschner wire were inserted and adequate reduction was confirmed on AP/LAT views under image intensifier. Another 1.6 mm K-wire percutaneously 90 degrees orthogonally to these wires starting at the dorsal rim of distal radius just distal to the Lister

  1. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  2. Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Chris Dillingham

    2011-01-01

    Full Text Available Purpose. To determine recovery timeline of unstable distal radius fractures treated by open reduction and internal fixation with a locking volar plate. Methods. Data was collected prospectively on a consecutive series of twenty-seven patients during routine post-operative visits at 2 and 6 weeks, and 3, 6, 12 and 24 months. Range of motion measures and grip strength for both wrists were recorded. Results. Greatest gains were made within the first 3 months after surgery. Supination and pronation returned more quickly than flexion or extension, with supination and pronation both at 92% of the uninjured wrist at 3 months. Only flexion improved significantly between 3 and 6 months. All wrist motions showed some improvement until 1 year. Grip strength returned to 94% of the uninjured wrist by 12 months. Conclusions. Range of motion improvement will be greatest between 2 weeks and 3 months, with improvement continuing until 12 months. Grip strength should return to near normal by one year. Function and pain will improve, but not return to normal by the end of 12 months. Clinical Relevance. These results provide the surgeon with information that can be shared with patients on the anticipated timeline for normal recovery of function and strength.

  3. Mid-term functional outcome after the internal fixation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Phadnis Joideep

    2012-01-01

    Full Text Available Abstract Background Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. Methods 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation = 10.4. Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. Results The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74% had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15% and in 11 patients were major (6%. Conclusion This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention.

  4. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    Science.gov (United States)

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore

  5. Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Michael [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Borders General Hospital, Department for Trauma and Orthopaedic Surgery, Melrose, Roxburghshire, Scotland (United Kingdom); Schroeder, Malte; Gruber-Rathmann, Michaela; Ruecker, Andreas H. [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Kossow, Kai [Department of Medical Psychology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2012-09-15

    Fractures of the distal radius are amongst the most common injury patterns. The dorsal tilt represents an important co-factor determining functional outcome. The purpose of this study was to analyze the radiological dorsal tilt and identify critical time frames in conservative and operative treatment of distal radius fractures. Eighty-seven conservatively treated (hematoma block assisted reduction and splinting) and 37 operatively treated (reduction, extra-focal K-wire fixation, bridging external fixateur) AO type A, B, and C fractures of the distal radius in 124 females were retrospectively analyzed. The dorsal tilt at the initial, post-reduction, and 2 weeks post-reduction stages was correlated with the final radiographic outcome at 6 weeks. Mean initial dorsal tilt was 16.53 in the conservatively treated group and 26.76 in the operatively treated group. Mean dorsal tilt after 6 weeks showed significant differences from the mean initial dorsal tilt at time of presentation within both groups (both groups p < 0.000). No significant differences between the two groups were found after 6 weeks of treatment (p = 0.194) regardless of the underlying AO fracture type. Conservatively treated radius fractures showed a significantly higher slip rate within the first 2 weeks (primary slip rate), whereas the operative group presented a significantly higher slip rate between the 2-week and 6-week radiographic checks (secondary slip rate). In terms of dorsal tilt, conservative (cast immobilization) and operative (K-wire fixation plus external fixateur) treatment demonstrated no significant differences at the final radiographic examination (6 weeks) regardless of the underlying AO fracture type. Both treatment groups showed treatment-associated different primary and secondary slip rates, indicating a need for more frequent radiographic checks within these critical time frames. (orig.)

  6. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    International Nuclear Information System (INIS)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E.

    2016-01-01

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  7. The shaft fractures of the radius and ulna in children: current concepts.

    Science.gov (United States)

    Sinikumpu, Juha-Jaakko; Serlo, Willy

    2015-05-01

    The incidence of forearm shaft fractures in children has increased in recent years. They are challenging to treat and they can result in several long-lasting complications. The treatment of children's fractures needs to be individualized to their needs. Nonoperative care will be satisfactory for young, preschool children and it is primarily treatment in stable fractures of children at every age. Injury mechanism must be understood to perform appropriate closed reduction. Immobilization using a long-arm cast needs to be focused against the deforming muscle forces - in particular those that rotate - in the forearm, keeping the bones in alignment until bone healing. Operative stabilization by elastic stable intramedullary nailing is the primarily method of treatment in cases of unstable fractures, in particular, in children between preschool age and adolescence. For older children near to skeletal maturity, a rigid plate and screw fixation will be justified. The most common complication after closed treatment is worsening of the alignment and need for repetitive interventions. elastic stable intramedullary nailing results usually in good outcome, and range of forearm rotation is the main feature determining the clinical result. In this article, we report the current concept of paediatric shaft fractures in the radius and ulna.

  8. The outcome of conservative treatment of adult distal radius fractures compared with the other wrist: radiological and functional evaluation

    Directory of Open Access Journals (Sweden)

    Mustafa Uslu

    2014-09-01

    Full Text Available Objective: This study was designed to evaluate anatomical and functional results of closed reduction-long arm cast treatment for distal radius fractures and compared other healthy wrist in the adults. Methods: 77 patients with distal radius fracture were treated conservatively between January 2010 and December 2010. The fractures were classified according to AO and Frykman classification system and investigated prospectively. The radiological and anatomical results were assessed by the Stewart score criteria. The functional results were assessed by Quick-Disability of Arm, Shoulder and Hand questionnaire (Q-DASH and the Stewart II score criteria. The mean follow-up of patients was 12 months. Results: The forty patients had right wrist fractured, 37 patients had left wrist fractured. According to Frykman classification 46 patients were type I-II fractured, according to AO classification 59 patients were type 23,A2,1 and 23,A2,2 fractured. According to Stewart the radiological and anatomical, the result were excellent in 57, good in 17, fair in 3. According to Stewart II functional criteria, the results were assessed excellent in 57, good in 8, fair in 12 The mean Q-DASH score was 6,37. The overall complication rate was 12.98%. Mild Carpal tunnel syndrome was observed in the two patients, ulna styloid nonunion in the four patients, pain of distal radioulnar joint in the one patient, mild carpal tunnel syndrome and tenderness of distal radioulnar joint in the three patients. Conclusion: Closed reduction and cast immobilization is still an effective and inexpensive treatment method in distal radial fractures. J Clin Exp Invest 2014; 5 (3: 403-409

  9. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  10. Radiographic diagnosis of scapholunate dissociation among intra-articular fractures of the distal radius: interobserver reliability

    NARCIS (Netherlands)

    Gradl, Gertraud; Neuhaus, Valentin; Fuchsberger, Thomas; Guitton, Thierry G.; Prommersberger, Karl-Josef; Ring, David; Wahegaonkar, Abhijeet L.; Shafritz, Adam B.; Garcia, Aida E.; Caputo, Andrew E.; Terrono, Andrew L.; Spoor, Andy B.; Eschler, Anica; Vochteloo, Anne J. H.; Beumer, Annechien; Barquet, Antonio; Kristan, Anze; van der Zwan, Arnard L.; Berner, Arne; Ilyas, Asif; Jubel, Axel; Sutker, Ben; Nolan, Betsy M.; Petrisor, Brad; Cross, Brian J.; Wills, Brian P. D.; Barreto, Camilo J. R.; Fernandes, Carlos H.; Swigart, Carrie; Zalavras, Charalampos; Goldfarb, Charles A.; Cassidy, Charles; Eaton, Charles; Wilson, Chris; Cheng, Christine J.; Wall, Christopher J.; Walsh, Christopher J.; Jones, Christopher M.; Garnavos, Christos; Klostermann, Cyrus; Kirkpatrick, D. Kay; Eygendaal, Denise; Verbeek, Diederik O. F.; Beeres, Frank J. P.; Thomas, George; Ponsen, Kornelis J.; van den Bekerom, Michel P. J.; Schep, Niels; Kloen, Peter; Haverlag, Robert

    2013-01-01

    To evaluate the reliability and accuracy of diagnosis of scapholunate dissociation (SLD) among AO type C (compression articular) fractures of the distal radius. A total of 217 surgeons evaluated 21 sets of radiographs with type C fractures of the distal radius for which the status of the

  11. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  12. The correlation of initial radiographic characteristics of distal radius fractures and injuries of the triangular fibrocartilage complex.

    Science.gov (United States)

    Kasapinova, K; Kamiloski, V

    2016-06-01

    Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. III. © The Author(s) 2016.

  13. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E. [University Medical Center Freiburg, Department of Radiology, Freiburg (Germany)

    2016-12-15

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  14. The reliability of AO classification for distal radius fracture, using CT findings

    International Nuclear Information System (INIS)

    Nakanishi, Yasuaki; Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryoutarou; Ota, Hiroyoshi

    2006-01-01

    The purpose of this study was to assess the reliability of the AO (Association for the Study of Internal Fixation) classification of distal radius fracture, using plain radiographs and 2 cross-sectional computed tomographic (CT) surface images. Five observers independently classified 32 distal radius fractures into 9 groups under AO classification. We established 4 methods for observation. First, using only two-directional radiographs; second, four-directional radiographs; third, CT (axial view) with four-directional radiographs; and fourth, CT (axial and sagittal views) with four-directional radiographs. Kappa statistics were used to establish the relative level of agreement between the observers. Interobserver reliability was poor in both first and second methods in which only plain radiographs were used (κ=0.30 and 0.23, respectively). Furthermore, reliability did not increase in the third method with the addition of 1 CT surface image (κ=0.29). In the fourth method, with the addition of 2 cross-sectional CT surface images, the reliability increased to a moderate level (κ=0.44). Interobserver reliability of the AO system of the classification of distal radius fractures was observed on using 2 cross-sectional CT surface images with four-directional radiographs. (author)

  15. A COMPARATIVE STUDY OF CONSERVATIVE MANAGEMENT VS. EXTERNAL FIXATION OF COMMINUTED DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Kare

    2016-12-01

    Full Text Available BACKGROUND Fracture of the distal radius (‘broken wrist’ is a common clinical problem. It can be treated conservatively usually involving wrist immobilisation in a plaster cast or surgically. A key method of surgical fixation is external fixation. MATERIALS AND METHODS A prospective study was carried out on 66 patients admitted between June 2014 to May 2016 for evaluation of conservative and surgical management of distal radius fractures. RESULTS Excellent, fair or good result was noticed in around 85% of cases managed conservatively and in above 90% of cases managed by external fixator. CONCLUSION There is some evidence to support the use of external fixation for dorsally displaced fractures of the distal radius in adults. Though, there is insufficient evidence to confirm a better functional outcome, external fixation reduces redisplacement gives improved anatomical results and most of the excess surgically-related complications are minor.

  16. The prevalence of pain and disability one year post fracture of the distal radius in a UK population: A cross sectional survey

    Directory of Open Access Journals (Sweden)

    Leonardi-Bee Jo

    2008-09-01

    Full Text Available Abstract Background A fracture of the distal radius is a commonly occurring fracture and accounts for a third of all fractures in the elderly. Thus far, one year estimates of pain and disability following a fracture of the distal radius have been reported on Canadian populations. The primary aim of this study is to investigate the prevalence of pain and disability in a UK population one year post fracture of the distal radius. Methods A cross-sectional survey was undertaken, of all subjects suffering a fracture of the distal radius between October 2005 and February 2006 in Nottingham, UK. Primary outcomes used were the VAS for pain and the DASH for disability. Prevalence of pain and disability were calculated and odds ratios presented for associations between demographics, pain and disability. Results 93/264 (35% subjects responded to the questionnaire. 6 subjects did not fulfill the inclusion criteria and were excluded from further analysis. 11% of subjects reported moderate to very severe pain. 16% of subjects reported moderate to very severe disability. Statistically significant associations were found between pain medication usage for the wrist fracture and moderate to very severe pain (OR 11.20, 95% CI 2.05 – 61.23. Moderate to very severe disability was associated with older age (OR 6.53, 95%CI 1.65 – 25.90 and pain medication usage for the wrist fracture (OR 4.75, 95% CI 1.38 – 16.37. Working was associated with a reduction in risk of moderate to very severe disability (OR 0.14, 95% CI 0.03 – 0.67. Conclusion This study demonstrates that there are a small proportion of patients who are still suffering moderate to very severe pain and disability one year post fracture of the distal radius. The study also demonstrates that there are significant associations between characteristics of the patients and the level of pain and disability. This highlights the need for further research into the most appropriate management of these patients

  17. [Injury to the Scapholunate Ligament in Distal Radius Fractures: Peri-Operative Diagnosis and Treatment Results].

    Science.gov (United States)

    Gajdoš, R; Pilný, J; Pokorná, A

    2016-01-01

    PURPOSE OF THE STUDY Injury to the scapholunate ligament is frequently associated with a fracture of the distal radius. At present neither a unified concept of treatment nor a standard method of diagnosis in these concomitant injuries is available. The aim of the study was to evaluate a group of surgically treated patients with distal radius fractures in order to assess a contribution of combined conventional X-ray and intra-operative fluoroscopic examinations to the diagnosis of associated lesions and to compare short-term functional outcomes of sugically treated patients with those of patients treated conservatively. MATERIAL AND METHODS A group of patients undergoiong surgery for distal radius fractures using plate osteosynthesis was evaluated retrospectively. The peri-operative diagnosis of associated injury to the scapholunate ligament was based on pre-operative standard X-ray views and intra-operative fluoroscopy. The latter consisted of images of maximum radial and ulnar deviation as well as an image of the forearm in traction exerted manually along the long axis. All views were in postero-anterior projection. Results were read directly on the monitor of a fluoroscopic device after its calibration or were obtained by comparing the thickness of an attached Kirschner wire with the distance to be measured. Subsequently, pixels were converted to millimetres. When a scapholunate ligament injury was found and confirmed by examination of the contralateral wrist, the finding was verified by open reduction or arthroscopy. Both static and dynamic instabilities were treated together with the distal radius fracture at one-stage surgery. After surgery, the patients without ligament injury had the wrist immobilised for 4 weeks, then rehabilitation followed. In the patients with a damaged ligament, immobilisation in a short brace lasted until transarticular wires were removed. All patients were followed up for a year at least. At follow-up, the injured wrist was examined

  18. Analysis of the Arthroscopically Diagnosed Soft-Tissue Injuries Associated With the Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Katerina Katerina Kasapinova

    2014-06-01

    CONCLUSIONS: The frequency of the associated soft-tissue lesions in distal radius fractures is high. Ulnar styloid fracture was identified as risk factor for associated LT lesion, as well as combined lesion of both scapholunate and luntriquetral ligament.

  19. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  20. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  1. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    Science.gov (United States)

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  2. Fractures of the shafts of the radius and ulna

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C.

    1985-01-01

    Although the clinical presentation of fracture of the forearm bones is usually quite obvious, thorough radiologic examination of the radius and ulna and adjacent wrist and elbow joints is mandatory. Standard views of the forearm of the patient include the AP and lateral projections. The degree of shortening, angulation, rotation, and comminution should be noted. The selected films must be long enough to include the adjacent elbow and wrist joints

  3. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    Science.gov (United States)

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  4. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  5. Clinical and functional outcome of open primary repair of triangular fibrocartilage complex tears associated with distal radius fractures.

    Science.gov (United States)

    Johandi, Faisal; Sechachalam, Sreedharan

    2017-01-01

    We evaluate the clinical and functional outcome of open primary repair of acute TFCC tears in distal radius fracture, when there is gross intraoperative distal radioulnar joint (DRUJ) instability after fixation of the distal radius, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed. A retrospective review of our institution's distal radius fracture database over a 4-year period (January 2010 to December 2013). A total of 12 (1.38%) out of 3379 patients had an open TFCC repair in the same setting as fixation of distal radius. Assessment of outcome involved the analysis of objective and subjective clinical and functional outcomes. All patient regained Activities of Daily Living (ADL) independence; eleven out of 12 patients (91.7%) returned to pre-injury function and 8 out of 11 patients (72.7%) returned to their jobs. DRUJ stability was preserved in 10 patients (83.3%) with 10 patients (83.3%) having grip strength of at least 50%, compared to the uninjured hand, and 7 (58.3%) with grip strength of more than or equal to 75%. Complications of surgery identified can be classified into 4 broad categories: infection, neurological complications, persistent DRUJ instability and prolonged pain. The authors believe a primary open repair of the TFCC should be considered when patients present with instability during intra-operative DRUJ ballottement test after distal radius fixation, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed.

  6. A new building block: costo-osteochondral graft for intra-articular incongruity after distal radius fracture.

    Science.gov (United States)

    Tang, Chris Yuk Kwan; Fung, Boris; Poon, T L; Fok, Margaret

    2014-01-01

    Even with the invention of locking plates, intra-articular fractures of distal radius with extreme comminution remain a challenge for orthopaedic surgeons. Osteochondral graft is a potential choice to reconstruct the articular defect. We report a patient who had a fracture of distal radius with costo-osteochondral graft for articular reconstruction which has not yet been described in the English literature. At nine-year follow-up, he was pain free and had full range of movement of the wrist. The authors suggest that costo-osteochondral graft could be an option with satisfactory result.

  7. The effect of search term on the quality and accuracy of online information regarding distal radius fractures.

    Science.gov (United States)

    Dy, Christopher J; Taylor, Samuel A; Patel, Ronak M; Kitay, Alison; Roberts, Timothy R; Daluiski, Aaron

    2012-09-01

    Recent emphasis on shared decision making and patient-centered research has increased the importance of patient education and health literacy. The internet is rapidly growing as a source of self-education for patients. However, concern exists over the quality, accuracy, and readability of the information. Our objective was to determine whether the quality, accuracy, and readability of information online about distal radius fractures vary with the search term. This was a prospective evaluation of 3 search engines using 3 different search terms of varying sophistication ("distal radius fracture," "wrist fracture," and "broken wrist"). We evaluated 70 unique Web sites for quality, accuracy, and readability. We used comparative statistics to determine whether the search term affected the quality, accuracy, and readability of the Web sites found. Three orthopedic surgeons independently gauged quality and accuracy of information using a set of predetermined scoring criteria. We evaluated the readability of the Web site using the Fleisch-Kincaid score for reading grade level. There were significant differences in the quality, accuracy, and readability of information found, depending on the search term. We found higher quality and accuracy resulted from the search term "distal radius fracture," particularly compared with Web sites resulting from the term "broken wrist." The reading level was higher than recommended in 65 of the 70 Web sites and was significantly higher when searching with "distal radius fracture" than "wrist fracture" or "broken wrist." There was no correlation between Web site reading level and quality or accuracy. The readability of information about distal radius fractures in most Web sites was higher than the recommended reading level for the general public. The quality and accuracy of the information found significantly varied with the sophistication of the search term used. Physicians, professional societies, and search engines should consider

  8. Patterns of triangular fibrocartilage complex (TFCC) injury associated with severely dorsally displaced extra-articular distal radius fractures.

    Science.gov (United States)

    Scheer, Johan H; Adolfsson, Lars E

    2012-06-01

    The aim of the study was to examine triangular fibrocartilage (TFCC) injury patterns associated with unstable, extra-articular dorsally displaced distal radius fractures. Twenty adult patients with an Arbeitsgemeinschaft für Osteosynthesefragen (AO), type A2 or A3, distal radius fracture with an initial dorsal angulation greater than 20° were included. Nine had a tip fracture (distal to the base) of the ulnar styloid and 11 had no such fracture. They were all openly explored from an ulnopalmar approach and TFCC injuries were documented. Eleven patients also underwent arthroscopy and intra-articular pathology was recorded. All patients had TFCC lesions of varying severity, having an extensor carpi ulnaris subsheath avulsion in common. Eighteen out of 20 also displayed deep foveal radioulnar ligament lesions, with decreasingly dorsal fibres remaining. The extent of this foveal injury could not be appreciated by radiocarpal arthroscopy. Severe displacement of an extra-articular radius fracture suggests an ulnar-sided ligament injury to the TFCC. The observed lesions concur with findings in a previous cadaver study. The lesions follow a distinct pattern affecting both radioulnar as well as ulnocarpal stabilisers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Fracture configurations of the equine radius and tibia after a simulated kick

    OpenAIRE

    Fürst, Anton; Oswald, Susanne E; Jäggin, S; Piskoty, G; Michel, S; Auer, Jörg A

    2008-01-01

    The objective of this postmortem study was to determine the fracture configurations of the equine radius and tibia after a simulated kick. Fracture configurations of 35 radii and 36 tibiae from 19 adult horses were evaluated after a simulated kick in an experimental exvivo study. The bones were dissected, the proximal and distal ends were embedded in resin, fixed horizontally and preloaded in compression, and a steel impactor, designed to simulate a shod equine hoof, was dropped from a height...

  10. AO Distal Radius Fracture Classification: Global Perspective on Observer Agreement

    Science.gov (United States)

    Jayakumar, Prakash; Teunis, Teun; Giménez, Beatriz Bravo; Verstreken, Frederik; Di Mascio, Livio; Jupiter, Jesse B.

    2016-01-01

    Background The primary objective of this study was to test interobserver reliability when classifying fractures by consensus by AO types and groups among a large international group of surgeons. Secondarily, we assessed the difference in inter- and intraobserver agreement of the AO classification in relation to geographical location, level of training, and subspecialty. Methods A randomized set of radiographic and computed tomographic images from a consecutive series of 96 distal radius fractures (DRFs), treated between October 2010 and April 2013, was classified using an electronic web-based portal by an invited group of participants on two occasions. Results Interobserver reliability was substantial when classifying AO type A fractures but fair and moderate for type B and C fractures, respectively. No difference was observed by location, except for an apparent difference between participants from India and Australia classifying type B fractures. No statistically significant associations were observed comparing interobserver agreement by level of training and no differences were shown comparing subspecialties. Intra-rater reproducibility was “substantial” for fracture types and “fair” for fracture groups with no difference accounting for location, training level, or specialty. Conclusion Improved definition of reliability and reproducibility of this classification may be achieved using large international groups of raters, empowering decision making on which system to utilize. Level of Evidence Level III PMID:28119795

  11. Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2018-04-01

    : Locking plate and external fixation is feasible to heal radius type C fracture. We found the small difference between the two groups on imaging examination. The locking plate has the advantage on maintaining reduction, however no significant difference regarding outcomes has been found between the two groups. Keywords: Locking plate, External fixation, Type C, Distal radius fractures, Meta-analysis

  12. Association of Insulin-like Growth Factor-1, Bone Mass and Inflammation to Low-energy Distal Radius Fractures and Fracture Healing in Elderly Women Attending Emergency Care.

    Science.gov (United States)

    Chisalita, Simona I; Chong, Lee Ti; Wajda, Maciej; Adolfsson, Lars; Woisetschläger, Mischa; Spångeus, Anna

    2017-11-01

    Elderly patients suffer fractures through low-energy mechanisms. The distal radius is the most frequent fracture localization. Insulin-like growth factor-1 (IGF1) plays an important role in the maintenance of bone mass and its levels decline with advancing age and in states of malnutrition. Our aim was to investigate the association of IGF1 levels, bone mass, nutritional status, and inflammation to low-energy distal radius fractures and also study if fracture healing is influenced by IGF1, nutritional status, and inflammation. Postmenopausal women, 55 years or older, with low-energy distal radius fractures occurring due to falling on slippery ground, indoors or outdoors, were recruited in the emergency department (ED) and followed 1 and 5 weeks after the initial trauma with biomarkers for nutritional status and inflammation. Fractures were diagnosed according to standard procedure by physical examination and X-ray. All patients were conservatively treated with plaster casts in the ED. Patients who needed interventions were excluded from our study. Fracture healing was evaluated from radiographs. Fracture healing assessment was made with a five-point scale where the radiological assessment included callus formation, fracture line, and stage of union. Blood samples were taken within 24 h after fracture and analyzed in the routine laboratory. Bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry (DXA). Thirty-eight Caucasian women, aged 70.5 ± 8.9 years (mean ± SD) old, were recruited. Nutritional status, as evaluated by albumin (40.3 ± 3.1 g/L), IGF1 (125.3 ± 39.9 μg/L), body mass index (26.9 ± 3.6 kg/m 2 ), arm diameter (28.9 ± 8.9 cm), and arm skinfold (2.5 ± 0.7 cm), was normal. A positive correlation was found between IGF1 at visit 1 and the lowest BMD for hip, spine, or radius (r = 0.39, P = 0.04). High sensitive C-reactive protein (hsCRP) and leukocytes were higher at the fracture event compared to 5 weeks later (P = 0.07 and P

  13. Complaints in the follow-up of conservatively treated distal radius fractures - predictors in the initial radiograph

    International Nuclear Information System (INIS)

    Freund, W.; Aschoff, A.J.; Einsiedel, T.; Kramer, M.; Trnavac, S.; Bezirkskrankenhaus Guenzburg

    2007-01-01

    Purpose: Radius fractures are frequent in adults, and the long-term results of conservative treatment remain disappointing. This study examines predictors for the clinical outcome in the initial radiograph. This will help to identify patients who will benefit from surgical treatment. Materials and Methods: A cohort study including a standardized telephone interview (Cooney score) was used to identify all conservatively treated patients with a distal radius fracture over a five-year period. The additional selection criteria were: over 15 years old, initial X-ray available, patient reachable by phone for the follow-up interview. The following measurements were taken from the initial radiograph: Radius-base angle, radial shortening, radiopalmar angle and intraarticular displacement. Correlations and a simple test to predict negative outcome were computed. Results: Of the initially identified 2211 patients with distal radius fracture, 179 also fulfilled the other criteria. The patients were 56.2 years old on average (standard deviation SD = ± 22.45 years) and 72 % were female. 60 % of the fractures were on the right side. The average follow-up was 4.3 years (SD ± 1.66). The Cooney score results averaged 85 points (with 100 being the optimal and maximum score), indicating good or very good functional results in the long term follow-up for 61 % of patients. However, 31 % received a rating of fair or poor and therefore had an unfavorable outcome. With respect to the correlations, age and shortening of the radius (but not gender) had a significant influence on the functional result. Using an age of 75 years or above and a radial shortening of at least 4 mm to predict an unfavorable outcome, the sensitivity is only 16 %, but the positive predictive value is 73 % and the specificity is 96 %. (orig.)

  14. Peak incidence of distal radius fractures due to ice skating on natural ice in The Netherlands

    NARCIS (Netherlands)

    van Lieshout, Arno P. W.; van Manen, Christiaan J.; du Pré, Karel J.; Kleinlugtenbelt, Ydo V.; Poolman, Rudolf W.; Goslings, J. Carel; Kloen, Peter

    2010-01-01

    An increase of distal radius fractures was seen in 2009 when an extended cold spell allowed natural ice skating in Amsterdam. This resulted in overload of our Emergency Departments and operating rooms. This study reports patient and fracture characteristics of these injuries. We also determined

  15. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    Science.gov (United States)

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  16. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    Science.gov (United States)

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Open Reduction in Pediatric Condylar Fracture.

    Science.gov (United States)

    Barbosa, Alexandre Agostini; Mariano, Ronaldo Célio

    2017-05-01

    Facial fractures in children are rare. Lack of pneumatization, fat pockets, mixed dentition, contribute to the elasticity and bone stability. When mandibular fractures occur in children, most often involve the condyle by indirect trauma. Such fractures are the center of discussion on the form of treatment if this should be performed conservatively, or held the reduction and fixation of the fracture with surgical exposure of the fragments. In condylar fractures in children, in most patients, the proposed treatment is closed reduction. Treatment with open reduction and fixation has its specific indications. In this case, the authors report a patient cycling accident victim, with cut-contusion injury in ment with limited mouth opening and left condylar fracture with medial rotation. The treatment was the reduction and fixation of fragments by open process.

  18. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  19. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  20. Ipsilateral dislocation of the radial head associated with fracture of distal end of the radius: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Gupta Vinay

    2013-06-01

    Full Text Available 【Abstract】Dislocation of the radial head in adults is uncommon. A simultaneous dislocation of the radial head and fracture of the ipsilateral distal end of radius with no other associated injuries is extremely rare. As far as we know, such an injury after an unusual mode of injury has been seldom reported in the English literature. We report such a case without any associated injuries or comorbidity. Closed reduction was performed within two hours after injury and results were satisfactory. Immobilisation was continued for 3 weeks. Gradual mobilisation was started after removal of the plaster under the supervision of a physiotherapist. At 6 months’ follow-up, the patient had no residual pain at the elbow with full flexion & extension. Almost full supination with a restriction of last 10 degrees of pronation was achieved. There was no evidence of instability of the elbow. Key words: Radial heads; Dislocations; Radius fractures

  1. [Treatment type C fracture of the distal radius with locking compression plate and external fixators].

    Science.gov (United States)

    Yang, Xiang; Zhao, You-ming; Chen, Lin; Ye, Cong-cong; Guo, Wei-jun; Wang, Bo

    2013-12-01

    To compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius. From January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up. Two cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,Pmeaning (t=-1.55, P>0.05). LCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.

  2. Feasibility of a reduction protocol in the emergency department for diaphyseal forearm fractures in children.

    Science.gov (United States)

    Pesenti, S; Litzelmann, E; Kahil, M; Mallet, C; Jehanno, P; Mercier, J-C; Ilharreborde, B; Mazda, K

    2015-09-01

    Diaphyseal forearm fractures are very common pediatric traumas. At present, distal radius metaphyseal fractures are often successfully treated with closed reduction by emergency physicians. However, the management of diaphyseal fractures remains controversial. The purpose of this study was to analyze the results of diaphyseal forearm fractures in the emergency department (ED) in children. In a prospective 2-year-study, all closed diaphyseal forearm fractures in patients under 15, with an angle of >15° and treated by closed reduction in the ED were included. Fractures with overlapping fragments were excluded. Reduction was performed by an emergency physician, with a standardized analgesic protocol (painkillers and nitrous oxide). Clinical tolerance was checked within the first 24hours, and the radiographic stability of reduction was assessed at days 8 and 15. Initial and final follow-up radiographs were analyzed. Elbow and wrist range of motion was assessed at the final follow-up. Sixty patients (41 boys and 19 girls) were included. Mean age was 5.2 years old (±3). At initial evaluation, the maximum angle was 30° (±11.3). After reduction, the maximum angle was significantly reduced (30° vs. 5°, P<0.001). Mean immobilization in a cast was 11.7 weeks (±2). There were no cast related complications in any of these children. There was no surgery for secondary displacement. Full range of motion was obtained in all patients at the final follow-up. The outcome of conservative treatment of closed diaphyseal forearm fractures, without overlapping fragments was excellent. However, reduction is usually performed in the operating room by orthopedic surgeons under general anesthesia and requires hospitalization, which is very expensive. The results of this study show that high quality care may be obtained in the ED by a trained and experienced team. These results are similar to those for distal metaphyseal fractures, which could extend the indications for reduction in the

  3. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

    Science.gov (United States)

    Sinicropi, Stefano M; Su, Brian W; Raia, Frank J; Parisien, May; Strauch, Robert J; Rosenwasser, Melvin P

    2005-03-01

    Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

  4. Effect of facility on the operative costs of distal radius fractures.

    Science.gov (United States)

    Mather, Richard C; Wysocki, Robert W; Mack Aldridge, J; Pietrobon, Ricardo; Nunley, James A

    2011-07-01

    The purpose of this study was to investigate whether ambulatory surgery centers can deliver lower-cost care and to identify sources of those cost savings. We performed a cost identification analysis of outpatient volar plating for closed distal radius fractures at a single academic medical center. Multiple costs and time measures were taken from an internal database of 130 consecutive patients and were compared by venue of treatment, either an inpatient facility or an ambulatory, stand-alone surgery facility. The relationships between total cost and operative time and multiple variables, including fracture severity, patient age, gender, comorbidities, use of bone graft, concurrent carpal tunnel release, and surgeon experience, were examined, using multivariate analysis and regression modeling to identify other cost drivers or explanatory variables. The mean operative cost was considerably greater at the inpatient facility ($7,640) than at the outpatient facility ($5,220). Cost drivers of this difference were anesthesia services, post-anesthesia care unit, and operating room costs. Total surgical time, nursing time, set-up, and operative times were 33%, 109%, 105%, and 35% longer, respectively, at the inpatient facility. There was no significant difference between facilities for the additional variables, and none of those variables independently affected cost or operative time. The only predictor of cost and time was facility type. This study supports the use of ambulatory stand-alone surgical facilities to achieve efficient resource utilization in the operative treatment of distal radius fractures. We also identified several specific costs and time measurements that differed between facilities, which can serve as potential targets for tertiary facilities to improve utilization. Economic and Decisional Analysis III. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Arthroscopic knotless anchor repair of triangular fibrocartilage in distal radius fracture.

    Science.gov (United States)

    García-Ruano, Á A; Najarro-Cid, F; Jiménez-Martín, A; Gómez de los Infantes-Troncoso, J G; Sicre-González, M

    2015-01-01

    Lesions of triangular fibrocartilage (TFC) are associated with distal radioulnar joint instability. Arthroscopic treatment of these lesions improves functional outcome of affected patients. The aim of the present work is to evaluate functional and occupational outcome of TCF repair using an arthroscopic knotless anchor device in patients with associated distal radius fracture. An observational, descriptive study was carried out between November 2011 and January 2014 including 21 patients with distal radius fracture and Palmer 1B lesions of TCF (Atzei class 2 and 3) that were treated by arthroscopic knotless anchor (PopLok® 2,8mm, ConMed, USA). Mean follow-up was 18 months. Functional (Mayo Wrist Score) and occupational outcome results were analyzed. Mean age of the group was 43.0±8.8 years, with 19% of the patients being female. There was an associated scapholunate lesion in 5 cases. Functional results reached a mean of 83.4±16.1 points onMayo Wrist Score. Mean sick-leave time was 153.16±48.5 days. Complete occupational reintegration was reached in 89.5% of cases. There were no postoperative complications. Arthroscopic knotless anchor repair of 1B TFC tears is a minimally invasive method of treatment that improves tension of fixation, avoiding subsequent loosen, in our experience, with few complications and good functional and occupational results. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  6. Distal radius fractures result in alterations in scapular kinematics: a three-dimensional motion analysis.

    Science.gov (United States)

    Ayhan, Cigdem; Turgut, Elif; Baltaci, Gul

    2015-03-01

    Scapular motion is closely integrated with arm motion. Injury to a distal segment requires compensatory changes in the proximal segments leading to alterations in scapular motion. Since the effects of distal injuries on scapular kinematics remain unknown, in the present study we investigated the influences on scapular motion in patients with distal injuries. Sixteen subjects with a history of distal radius fracture and 20 asymptomatic healthy subjects (controls) participated in the study. Three-dimensional scapular and humeral kinematic data were collected on all 3 planes of shoulder elevation: frontal, sagittal, and scapular. All testing was performed in a single session; therefore, the sensors remained attached to the participants for all testing. The position and orientation data of the scapula at 30°, 60°, 90°, and 120° humerothoracic elevation and 120°, 90°, 60°, and 30° lowering were used for statistical comparisons. Independent samples t-test was used to compare the scapular internal/external rotation, upward/downward rotation, and anterior/posterior tilt between the affected side of subjects with a distal radius fracture and the dominant side of asymptomatic subjects at the same stage of humerothoracic elevation. Scapular internal rotation was significantly increased at 30° elevation (P=0.01), 90° elevation (P=0.03), and 30° lowering (P=0.03), and upward rotation was increased at 30° and 60° elevation (Pplane elevation. Scapular upward rotation and anterior tilt were significantly increased during 30° lowering on both the scapular (P=0.002 and 0.02, respectively) and sagittal planes (P=0.01 and 0.02. respectively). Patients with distal radius fractures exhibit altered scapular kinematics, which may further contribute to the development of secondary musculoskeletal pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Effects of circumferential rigid wrist orthoses in rehabilitation of patients with radius fracture at typical site

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2005-01-01

    Full Text Available Background. The use of orthoses is a questionable rehabilitation method for patients with the distal radius fracture at typical site. The aim of this study was to compare the effects of the rehabilitation on patients with radius fracture at the typical site, who wore circumferential static wrist orthoses, with those who did not wear them. Methods. Thirty patients were divided into 3 equal groups, 2 experimental groups, and 1 control group. The patients in the experimental groups were given the rehabilitation program of wearing serially manufactured (off-the-shelf, as well as custom-fit orthoses. Those in the control group did not wear wrist orthoses. Evaluation parameters were pain, edema, the range of the wrist motion, the quality of cylindrical, spherical, and pinch-spherical grasp, the strength of pinch and hand grasp, and patient's assessment of the effects of rehabilitation. Results. No significant difference in the effects of rehabilitation on the patients in experimental groups as opposed to control group was found. Patients in the first experimental group, and in control group were more satisfied with the effects of rehabilitation, as opposed to the patients in the second experimental group (p<0,05. Conclusion. The effects of circumferential static wrist orthoses in the rehabilitation of patients with distal radius fracture at the typical site were not clinically significant. There was no significant difference between the custom and off-the-shelf orthoses.

  8. Midterm Follow-up of Treating Volar Marginal Rim Fractures with Variable Angle Lcp Volar Rim Distal Radius Plates.

    Science.gov (United States)

    Goorens, Chul Ki; Geeurickx, Stijn; Wernaers, Pascal; Staelens, Barbara; Scheerlinck, Thierry; Goubau, Jean

    2017-06-01

    Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating

  9. Examination of Skill Acquisition and Grader Bias in a Distal Radius Fracture Fixation Model.

    Science.gov (United States)

    Putnam, Matthew D; Adams, Julie E; Lender, Paul; Van Heest, Ann E; Shanedling, Janet R; Nuckley, David J; Bechtold, Joan E

    2018-03-01

    Primary: Assess the ability of faculty graders to predict the objectively measured strength of distal radius fracture fixation. Secondary: Compare resident skill variation and retention related to other knowable training data. Residents were allowed 60 minutes to stabilize a standardized distal radius fracture using an assigned fixed-angle volar plate. Faculty observed and subjectively graded the residents without providing real-time feedback. Objective biomechanical evaluation (construct strength and stiffness) was compared to subjective grades. Resident-specific characteristics (sex, PGY, and ACGME case log) were also used to compare the objective data. A simulated operating room in our laboratory. Post-graduate year 2, 3, 4, and 5 orthopedic residents. Primary: Faculty were not successful at predicting objectively measured fixation, and their subjective scoring suggests confirmation bias as PGY increased. Secondary: Resident year-in-training alone did not predict objective measures (p = 0.53), but was predictive of subjective scores (p external faculty unfamiliar with tested residents, might alter these results. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  10. Trajectories in quality of life of patients with a fracture of the distal radius or ankle using latent class analysis

    NARCIS (Netherlands)

    van Son, M.A.C.; de Vries, J.; Zijlstra, W.; Roukema, J.A.; Gosens, T.; Verhofstad, M. H. J.; den Oudsten, B.L.

    2017-01-01

    Purpose This prospective study aimed to identify the different trajectories of quality of life (QOL) in patients with distal radius fractures (DRF) and ankle fractures (AF). Secondly, it was examined if subgroups could be characterized by sociodemographic, clinical, and psychological variables.

  11. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Directory of Open Access Journals (Sweden)

    MacDermid Joy C

    2005-11-01

    Full Text Available Abstract Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE, The Wrist Outcome Measure (WOM, and the Medical Outcome Survey Short-Form (SF-36 were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week and 33% (three months of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months and 8% (one year. Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture.

  12. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Science.gov (United States)

    Harris, Jocelyn E; MacDermid, Joy C; Roth, James

    2005-01-01

    Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE), The Wrist Outcome Measure (WOM), and the Medical Outcome Survey Short-Form (SF-36) were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week) and 33% (three months) of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months) and 8% (one year). Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture. PMID:16288664

  13. Effect of finite edge radius on ductile fracture ahead of the cutting tool edge in micro-cutting of Al2024-T3

    International Nuclear Information System (INIS)

    Subbiah, Sathyan; Melkote, Shreyes N.

    2008-01-01

    Evidence of ductile fracture leading to material separation has been reported recently in ductile metal cutting [S. Subbiah, S.N. Melkote, ASME J. Manuf. Sci. Eng. 28(3) (2006)]. This paper investigates the effect of finite edge radius on such ductile fracture. The basic question of whether such ductile fracture occurs in the presence of a finite edge radius is explored by performing a series of experiments with inserts of different edge radii at various uncut chip thickness values ranging from 15 to 105 μm. Chip-roots are obtained in these experiments using a quick-stop device and examined in a scanning electron microscope. Clear evidence of material separation is seen at the interface zone between the chip and machined surface even when the edge radius is large compared to the uncut chip thickness. Failure is seen to occur at the upper, middle, and/or the lower edges of the interface zone. Based on these observations, a hypothesis is presented for the events leading to the occurrence of this failure when cutting with an edge radius tool. Finite element simulations are performed to study the nature of stress state ahead of the tool edge with and without edge radius. Hydrostatic stress is seen to be tensile in front of the tool and hence favors the occurrence of ductile fracture leading to material separation. The stress components are, however lower than those seen with a sharp tool

  14. Factors in secondary prevention subsequent to distal radius fracture : Focus on physical function, co-morbidity, bone mineral density and health-related quality of life

    OpenAIRE

    Nordvall, Helena

    2009-01-01

    In Sweden approximately 25000 distal radius fractures occur annually, which is 37 % of all fractures related to osteoporosis. In this thesis, risk factors for osteoporosis, bone mineral density (BMD) and health-related quality of life (the SF-36) were compared in patients who suffered a distal radius fracture after low energy trauma with a control group matched on the basis of age, gender, and municipality of residence. The aim was also to analyse, among these patients, whether a risk factor ...

  15. Fixation via dorsal for complex fractures of radius distal with plate P

    International Nuclear Information System (INIS)

    Rojas, Sandra; Bocanegra, Sergio; Suarez, Fabio

    2002-01-01

    The existence of multiple alternatives in the handling of the complex fractures of the radius distal it constitutes a reflection of the challenge that these they represent as for the possibility of recovering an appropriate consistency to articulate and orientation and radial height. This prospective study included 13 patients assisted in the hospital military of Bogota, by means of internal fixation with plate π. This treatment alternative, it solves many present inconveniences with other methods and it allows the precocious postoperative rehabilitation

  16. Epidemiology of distal radius fractures in polytrauma patients and the influence of high traumatic energy transfer.

    Science.gov (United States)

    Ferree, Steven; van der Vliet, Quirine M J; Nawijn, Femke; Bhashyam, Abhiram R; Houwert, Roderick M; Leenen, Luke P H; Hietbrink, Falco

    2018-03-01

    For several extremity fractures differences in morphology, incidence rate and functional outcome were found when polytrauma patients were compared to patients with an isolated injury. This is not proven for distal radius fractures (DRF). Therefore, this study aimed to analyse fracture morphology in relation to energy transfer in both poly- and mono-trauma patients with a DRF. This was a retrospective cohort study. All patients aged 16 years and older with a DRF were included. Patients with an Injury Severity Score of 16 or higher were classified as polytrauma patients. Injuries were defined as high or low energy. All DRFs were classified using the AO/OTA fracture classification system. A total of 830 patients with a DRF were included, 12% were polytrauma. The incidence rate of DRF in polytrauma patients was 3.5%. Ipsilateral upper extremity injury was found in >30% of polytrauma and high-energy monotrauma patients, compared to 5% in low-energy monotrauma patients. More type C DRF were found in polytrauma and high-energy monotrauma patients versus low-energy monotrauma patients. Operative intervention rates for all types of DRF were similar for polytrauma and high-energy monotrauma patients. Non-union rates were higher in polytrauma patients. Higher energy mechanisms of injury, in polytrauma and high-energy monotrauma patients, were associated with more severe complex articular distal radius fractures and more ipsilateral upper extremity injuries. Polytrauma and high-energy monotrauma patient have a similar fracture morphology. However, polytrauma patients have in addition to more injured body regions also more non-union related interventions than high-energy monotrauma patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Cross-education for improving strength and mobility after distal radius fractures: a randomized controlled trial.

    Science.gov (United States)

    Magnus, Charlene R A; Arnold, Cathy M; Johnston, Geoffrey; Dal-Bello Haas, Vanina; Basran, Jenny; Krentz, Joel R; Farthing, Jonathan P

    2013-07-01

    To evaluate the effects of cross-education (contralateral effect of unilateral strength training) during recovery from unilateral distal radius fractures on muscle strength, range of motion (ROM), and function. Randomized controlled trial (26-wk follow-up). Hospital, orthopedic fracture clinic. Women older than 50 years with a unilateral distal radius fracture. Fifty-one participants were randomized and 39 participants were included in the final data analysis. Participants were randomized to standard rehabilitation (Control) or standard rehabilitation plus strength training (Train). Standard rehabilitation included forearm casting for 40.4±6.2 days and hand exercises for the fractured extremity. Nonfractured hand strength training for the training group began immediately postfracture and was conducted at home 3 times/week for 26 weeks. The primary outcome measure was peak force (handgrip dynamometer). Secondary outcomes were ROM (flexion/extension; supination/pronation) via goniometer and the Patient Rated Wrist Evaluation questionnaire score for the fractured arm. For the fractured hand, the training group (17.3±7.4kg) was significantly stronger than the control group (11.8±5.8kg) at 12 weeks postfracture (P<.017). There were no significant strength differences between the training and control groups at 9 (12.5±8.2kg; 11.3±6.9kg) or 26 weeks (23.0±7.6kg; 19.6±5.5kg) postfracture, respectively. Fractured hand ROM showed that the training group had significantly improved wrist flexion/extension (100.5°±19.2°) than the control group (80.2°±18.7°) at 12 weeks postfracture (P<.017). There were no significant differences between the training and control groups for flexion/extension ROM at 9 (78.0°±20.7°; 81.7°±25.7°) or 26 weeks (104.4°±15.5°; 106.0°±26.5°) or supination/pronation ROM at 9 (153.9°±23.9°; 151.8°±33.0°), 12 (170.9°±9.3°; 156.7°±20.8°) or 26 weeks (169.4°±11.9°; 162.8°±18.1°), respectively. There were no

  18. Identification of fracture zones and its application in automatic bone fracture reduction.

    Science.gov (United States)

    Paulano-Godino, Félix; Jiménez-Delgado, Juan J

    2017-04-01

    The preoperative planning of bone fractures using information from CT scans increases the probability of obtaining satisfactory results, since specialists are provided with additional information before surgery. The reduction of complex bone fractures requires solving a 3D puzzle in order to place each fragment into its correct position. Computer-assisted solutions may aid in this process by identifying the number of fragments and their location, by calculating the fracture zones or even by computing the correct position of each fragment. The main goal of this paper is the development of an automatic method to calculate contact zones between fragments and thus to ease the computation of bone fracture reduction. In this paper, an automatic method to calculate the contact zone between two bone fragments is presented. In a previous step, bone fragments are segmented and labelled from CT images and a point cloud is generated for each bone fragment. The calculated contact zones enable the automatic reduction of complex fractures. To that end, an automatic method to match bone fragments in complex fractures is also presented. The proposed method has been successfully applied in the calculation of the contact zone of 4 different bones from the ankle area. The calculated fracture zones enabled the reduction of all the tested cases using the presented matching algorithm. The performed tests show that the reduction of these fractures using the proposed methods leaded to a small overlapping between fragments. The presented method makes the application of puzzle-solving strategies easier, since it does not obtain the entire fracture zone but the contact area between each pair of fragments. Therefore, it is not necessary to find correspondences between fracture zones and fragments may be aligned two by two. The developed algorithms have been successfully applied in different fracture cases in the ankle area. The small overlapping error obtained in the performed tests

  19. Open segmental fracture of both bone forearm and dislocation of ipsilateral elbow with extruded middle segment radius

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2013-01-01

    Full Text Available Extruded middle segment of radius with open segmental fracture both bone forearm and dislocation of ipsilateral elbow is a rare injury. A 12-year-old child presented to us within 4 hours following fall from tree. The child′s mother was carrying a 12-cm-long extruded soiled segment of radius. The extruded bone was thoroughly washed. The medullary cavity was properly syringed with antiseptic solution. The bone was autoclaved and put in the muscle plane of the distal forearm after debridement of the wound. After 5 days, a 2.5-mm K-wire was introduced by retrograde method into the proximal radius by passing through the extruded segment. Another 2.5-mm K-wire was passed in ulna. The limb was evaluated clinicoradiologically every 2 weeks. The wound was healed by primary intention. At 4 months, the reposed bone appeared less dense radiologically and K-wire seemed to be out of the bone. In the subsequent months, the roentgenograms show remodeling of the extruded fragment. After 20 weeks, the K-wires were removed (first ulnar and then radial. Complete union was achieved with full range of movement except loss of few degrees of extension of elbow and thumb. This case is reported to show a good outcome following successful incorporation of an extruded segment of radius in an open fracture.

  20. Bone strength and muscle properties in postmenopausal women with and without a recent distal radius fracture.

    Science.gov (United States)

    Crockett, K; Arnold, C M; Farthing, J P; Chilibeck, P D; Johnston, J D; Bath, B; Baxter-Jones, A D G; Kontulainen, S A

    2015-10-01

    Distal radius (wrist) fracture (DRF) in women over age 50 years is an early sign of bone fragility. Women with a recent DRF compared to women without DRF demonstrated lower bone strength, muscle density, and strength, but no difference in dual-energy x-ray absorptiometry (DXA) measures, suggesting DXA alone may not be a sufficient predictor for DRF risk. The objective of this study was to investigate differences in bone and muscle properties between women with and without a recent DRF. One hundred sixty-six postmenopausal women (50-78 years) were recruited. Participants were excluded if they had taken bone-altering medications in the past 6 months or had medical conditions that severely affected daily living or the upper extremity. Seventy-seven age-matched women with a fracture in the past 6-24 months (Fx, n = 32) and without fracture (NFx, n = 45) were measured for bone and muscle properties using the nondominant (NFx) or non-fractured limb (Fx). Peripheral quantitative computed tomography (pQCT) was used to estimate bone strength in compression (BSIc) at the distal radius and tibia, bone strength in torsion (SSIp) at the shaft sites, muscle density, and area at the forearm and lower leg. Areal bone mineral density at the ultradistal forearm, spine, and femoral neck was measured by DXA. Grip strength and the 30-s chair stand test were used as estimates of upper and lower extremity muscle strength. Limb-specific between-group differences were compared using multivariate analysis of variance (MANOVA). There was a significant group difference (p lower leg, with the Fx group demonstrating 16 and 19% lower BSIc, 3 and 6% lower muscle density, and 20 and 21% lower muscle strength at the upper and lower extremities, respectively. There were no differences between groups for DXA measures. Women with recent DRF had lower pQCT-derived estimated bone strength at the distal radius and tibia and lower muscle density and strength at both extremities.

  1. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2012-01-01

    the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees.

  2. The art of trochanteric fracture reduction.

    Science.gov (United States)

    Biber, Roland; Berger, Johanna; Bail, Hermann Josef

    2016-12-01

    The name of Ender is primarily associated with the Ender nails, which were popular for trochanteric fracture fixation more than thirty years ago. However, Ender's concepts were not limited to the implant. Ender developed a unique classification system for trochanteric and subtrochanteric fractures, which provided the theory for closed reduction maneuvers that made the method so successful in his hands. While Ender's nails have become history in the meantime, his principles of fracture reduction can be readily applied on surgery with modern implants such as proximal femoral nails. This article reflects the classification and the principles published by Hans Georg Ender in some print work hardly available nowadays. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?

    International Nuclear Information System (INIS)

    Menachem, S.; Sharfman, Z.T.; Perets, I.; Arami, A.; Eyal, G.; Drexler, M.; Chechik, O.

    2016-01-01

    Aim: To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. Materials and methods: A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. Results: The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1–16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. Conclusion: The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. - Highlights: • Compared outcomes of pediatric forearm fracture reduction with and without fluoroscopy. • The use of fluoroscopy during reduction of forearm fractures in the pediatric population apparently does not have a

  4. Mechanism of distal radius fracture as analyzed by 3D finite element model

    International Nuclear Information System (INIS)

    Tomizawa, Kazuo

    2007-01-01

    The purpose of this study is to see the difference of distal radius fracture between normal and osteoporotic bones and in its patterns due to limb position at injury through simulation and analysis of the biomechanics using three-dimensional (3D) finite element model. CT images were taken with SIEMENS machine, of right wrist joints of 32 and 76 years old, normal healthy man and osteoporotic woman, respectively. The wrist joint angles at CT were 70 degrees both at dorsiflexion and at palmerflexion for simulating fracture at tumbling down. The 3D bone model reconstructed from CT images with Forge software (Studio PON) was trimmed to remain the distal radial-ulnar portion and proximal carpal bones to make simulation easer, and the simplified 3D model was divided to 56,622 elements and 13,274 nodal points (normal bone) or 51,760 and 12,940 (osteoporosis), respectively, in 3 areas of different bone densities calculated with Scion Image processor. This 3D finite element model was analyzed with the software ANSYS LS-DYNA 10.0 for simulating the fracture (the defined yield stress attained) by impacting the elements of carpal bones to the radial bone joint surface with a measure of Mises stress. In osteoporotic bone, fracture was found to occur at dorsal cortex closer to the joint surface. Fracture occurred at dorsal and palmer cortex at dorsiflexion and palmerflexion, respectively. (R.T.)

  5. [Growth behaviour after fractures of the proximal radius: differences to the rest of the skeleton].

    Science.gov (United States)

    Hell, A K; von Laer, L

    2014-12-01

    Fractures of the proximal end of the radius in the growth phase have three characteristics: the head of the radius articulates with two joint partners and is therefore indispensable for an undisturbed function of the elbow. The blood supply of the proximal end of the radius is via periosteal vessels in the sense of a terminal circulation which makes it extremely vulnerable. Severe trauma caused either by accidents or treatment, can result in partial or complete necrosis with deformity of the head and neck region of the radius. Radioulnar synostosis and chronic epiphysiolysis are irreversible complications which can occur after excessive physiotherapy. Despite a low potency growth plate, in young patients the proximal end of the radius shows an enormous spontaneous correction of dislocations. Side to side shifts, however, will not be remodeled. Therapy should be as atraumatic as possible. Due to the blood supply situation, with the appropriate indications the spontaneous correction and a brief period of immobilization without physiotherapy should be integrated into the therapy concept. If an operation is necessary, repeated traumatic repositioning maneuvers should be avoided and in case of doubt closed or careful open repositioning can be achieved with intramedullary nailing. In order to take the special characteristics of the proximal radius into consideration, the vulnerability and correction potential must be weighed up against each other. Therapy must be as atraumatic as possible. The spontaneous correction potential should be integrated into the primary therapy without overestimating this potential with respect to the extent and age of the patient.

  6. Radiographic evaluation of acute distal radius fracture stability: A comparative cadaveric study between a thermo-formable bracing system and traditional fiberglass casting.

    Science.gov (United States)

    Santoni, Brandon G; Aira, Jazmine R; Diaz, Miguel A; Kyle Stoops, T; Simon, Peter

    2017-08-01

    Distal radius fractures are common musculoskeletal injuries and many can be treated non-operatively with cast immobilization. A thermo-formable brace has been developed for management of such fractures, but no data exist regarding its comparative stabilizing efficacy to fiberglass casting. A worst-case distal radius fracture was created in 6 cadaveric forearms. A radiolucent loading fixture was created to apply cantilever bending/compression loads ranging from 4.5N to 66.7N across the simulated fracture in the: (1) non-stabilized, (2) braced; and (3) casted forearms, each forearm serving as its own control. Fracture fragment translations and rotations were measured radiographically using orthogonal radiographs and a 2D-3D, CT-based transformation methodology. Under 4.5N of load in the non-stabilized condition, average sagittal plane rotation and 3D center of mass translation of the fracture fragment were 12.3° and 5.3mm, respectively. At the 4.5N load step, fragment rotation with the brace (avg. 0.0°) and cast (0.1°) reduced sagittal plane rotation compared to the non-stabilized forearm (Pthermo-formable brace stabilized the fracture in a manner that was not radiographically or biomechanically different from traditional fiberglass casting. Study results support the use of the thermo-formable brace clinically. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR “DIE PUNCH” DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2015-01-01

    Objective: the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. Methods: There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. Results: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. Conclusion: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. PMID:27027079

  8. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    OpenAIRE

    Choi, Kang-Young; Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and de...

  9. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases

    OpenAIRE

    St-Jean, Guy; Debowes, Richard M.

    1992-01-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.

  10. [Clinical observation on the effect of joint mobilization in treating elderly patients after distal radius fractures operation].

    Science.gov (United States)

    Jia, Xue-Feng; Cai, Hong-Xin; Lin, Ge-Sheng; Fang, Ji-Shi; Wang, Yong; Wu, Zhi-Yong; Tu, Xu-Hui

    2017-07-25

    To investigate the effect of joint mobilization on postoperative wrist joint function, pain and grip strength for elderly patients with distal radius fracture. From January 2015 to June 2016, a total of 67 elderly patients with distal radius fracture were randomly divided into routine exercise group and joint mobilization group. Among them, 37 patients in the routine exercise group underwent conventional distal radius fracture postoperative joint function exercise regimen, including 16 males and 21 females with a mean age of (67.8±3.2) years old ranging from 60 to 72 years old;the injured side was dominant in 23 cases and non-dominant in 14 cases;injury mechanism was fall in 26 cases, traffic accident in 11 cases; for AO type, 6 cases were type B3, 18 cases were type C1, 7 cases were type C2, 6 cases was type C3. Other 30 patients in the joint mobilization group underwent joint mobilization on the basis of the routine exercise group including 14 males and 16 females with a mean age of (67.1±4.0) years old ranging from 61 to 74 years old; the injured side was dominant in 21 cases and non-dominant in 9 cases;injury mechanism was fall in 25 cases, traffic accident in 5 cases;for AO type, 8 cases were type B3, 13 cases were type C1, 6 cases were type C2, 9 cases were type C3. The wrist joint activity, Gartland-Werley wrist joint function score, VAS pain score and grip strength were observed at 3 months afrer treatment. After 3 months' treatment, the VAS in the routine exercise group was higher than that of the joint mobilization group ( P joint mobilization group was higher than that in routine exercise group( P joint mobilization group( P joint mobilization group had no significant difference ( P >0.05). In the comparison of each item of Gartland-Werley, there was no significant difference between two groups in residual deformity and complication( P >0.05); the average score of subjective score, objective score and total score in routine exercise group were

  11. Elbow dislocation with ipsilateral fracture of the distal radius associated with a brachial artery injury: A new pathological condition of traumatic origin.

    Science.gov (United States)

    Trigo Lahoz, L; Lamas Gomez, C; Sarasquete Reiriz, J; de Caso Rodriguez, J; Proubasta Renart, I

    Elbow dislocation associated with ipsilateral fracture of the distal radius and a brachial artery injury is an uncommon traumatic entity. The two references of this injury combination appeared in 2015, although both authors did not realise that they were the first two cases published in the medical literature. Although mentioned in the text of the articles, no mention was made of the fracture of the distal radius in the titles. The purpose of this paper is to present three cases with this new traumatic pathological entity, explaining its pathogenetic mechanism, the treatment used, and the results obtained. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Timing of Surgical Reduction and Stabilization of Talus Fracture-Dislocations.

    Science.gov (United States)

    Buckwalter V, Joseph A; Westermann, Robert; Mooers, Brian; Karam, Matthew; Wolf, Brian

    Talus fractures with associated dislocations are rare but have high rates of complications, including avascular necrosis (AVN). Management of these injuries involves urgent surgical reduction and fixation, although there are no definitive data defining an operative time frame for preserving the blood supply and preventing complications. To determine the effect of time to surgical reduction of talus fractures and talus fracture-dislocations on rates of AVN and posttraumatic osteoarthritis (PTOA), we retrospectively reviewed talus fractures surgically managed at a level I trauma center during the 10-year period 2003 to 2013. Operative reports were obtained and reviewed, and 3 independent reviewers, using the Hawkins and AO/OTA (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association) systems, classified the injuries on plain radiographs. Analysis of AO/OTA 81 fractures with associated tibiotalar, subtalar, or talonavicular dislocations was performed. Primary outcomes were presence of AVN/PTOA and subsequent arthrodesis of tibiotalar or subtalar joints. We identified 106 surgically managed talus fractures. Rates of AVN/PTOA were 41% for all talus fractures and 50% for talus fracture-dislocations. Mean time to surgical reduction was not significant for development of AVN/PTOA for all talus fractures (P = .45) or talus fracture-dislocations (P = .29). There was no difference in age (P = .20), body mass index (P = .45), or polytrauma (P = .79) between patients who developed AVN and those who did not. Open fractures were significantly correlated with the development of AVN/PTOA (P = .009). Talar fracture-dislocations are devastating injuries with high rates of complications. Our data suggest there is no effect of time from injury to surgical reduction of talus fractures or talus fracture-dislocations on rates of AVN and PTOA.

  13. New quantitative ultrasound techniques for bone analysis at the distal radius in hip fracture cases: differences between femoral neck and trochanteric fractures.

    Science.gov (United States)

    Horii, Motoyuki; Fujiwara, Hiroyoshi; Sakai, Ryo; Sawada, Koshiro; Mikami, Yasuo; Toyama, Syogo; Ozaki, Etsuko; Kuriyama, Nagato; Kurokawa, Masao; Kubo, Toshikazu

    2017-01-01

    Ample evidence on etiological and pathological differences between femoral neck and trochanteric fracture cases suggests the possibility of individualized treatment. There are many issues related to areal bone mineral density and other quantitative computed tomography parameters of the proximal femur. Although osteoporosis is a systemic problem, little has been reported regarding differences in bone structural parameters, including bone mineral density, between them in regions other than the proximal femur. Participants were consecutive female patients >50 years of age admitted to the Saiseikai Suita Hospital (Osaka prefecture, Japan) for their first hip fracture between January 2012 and September 2014. Cortical thickness (CoTh, mm), volumetric trabecular bone mineral density (TBD, mg/cm 3 ), and elastic modulus of trabecular bone (EMTb, GPa) were obtained as the new QUS parameters using the LD-100 system (Oyo Electric, Kyoto, Japan). The mean values of these parameters were compared between femoral neck and trochanteric fracture cases. In addition, correlations between age and each QUS parameter were investigated for each fracture type. A receiver operating characteristic (ROC) curve analysis was performed to examine the degree of effect each parameter on the fracture types. The area under the curve (AUC) for each parameter was compared to the AUC for age. There were 63 cases of femoral neck fracture (mean age, 78.2 years) and 37 cases of trochanteric fracture (mean age, 85.9 years). Mean TBD and EMTb were significantly higher for femoral neck fractures. There were significant negative correlations between QUS parameters and age for femoral neck fractures (P fractures were above those for trochanteric fractures for TBD and EMTb. AUCs were 0.72 for age, and 0.61, 0.65, and 0.65 for CoTh, TBD, and EMTb, respectively. The new QUS parameters indicated that TR fracture cases were more osteoporotic than were FN fracture cases, even at the distal radius. There might be

  14. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material.

    Science.gov (United States)

    Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Takahashi, Kazuhisa

    2014-11-01

    Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.

  15. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Science.gov (United States)

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and deviation of the mandible. In the past, closed reduction with concomitant active physical therapy conducted after intermaxillary fixation during the recovery period had been mainly used, but in recent years, open treatment of condylar fractures with rigid internal fixation has become more common. The objective of this review was to evaluate the main variables that determine the choice of an open or closed method for treatment of condylar fractures, identifying their indications, advantages, and disadvantages, and to appraise the current evidence regarding the effectiveness of interventions that are used in the management of fractures of the mandibular condyle. PMID:22872831

  16. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and deviation of the mandible. In the past, closed reduction with concomitant active physical therapy conducted after intermaxillary fixation during the recovery period had been mainly used, but in recent years, open treatment of condylar fractures with rigid internal fixation has become more common. The objective of this review was to evaluate the main variables that determine the choice of an open or closed method for treatment of condylar fractures, identifying their indications, advantages, and disadvantages, and to appraise the current evidence regarding the effectiveness of interventions that are used in the management of fractures of the mandibular condyle.

  17. [True/Flex intramedullary nailing for forearm shaft fractures. Long-term results].

    Science.gov (United States)

    Trlica, J; Počepcov, I; Kočí, J; Frank, M; Holeček, T; Dědek, T

    2012-01-01

    Presentation of technical experience and the clinical and functional results of intramedullary fixation of forearm shaft fractures. Between January 1994 and December 2009, a total of 96 patients with 144 radial and/or ulnar fractures (ulna, 33; radius,15; both, 48) were treated by nailing (True/Flex®). According to the AO classification there were 22-A, 22-B and 22-C type fractures in 39 (41%), 44 (46%) and 13 (13%).cases, respectively. Of these, 82 (85%) were closed (types: 0, 48; I, 33; II, 1) and 14 (15%) were open (types: I, 13; II, 1; III, 0) fractures. Seventy-eight patients (81%) were followed up and their functional outcomes were evaluated according to the criteria of Anderson et al. The average interval between the operation and final follow-up was 28 months (15 to 96 months) The average time to surgery was 2.2 days (0 to 25 days). Early complications were recorded in 4% of the patients (1x bursitis olecrani; 1x end cup replacement; 1x bending of nails) and late complications in 15% (5x non-union; 2x delay union; 4x bursitis olecrani; 1x ruptured tendon). Bone healing was achieved in 95% of the cases and took on average 16 weeks (7 to 34 weeks). No infection, refracture or synostosis occurred. Primary loss of reduction was recorded in four cases due to distraction in one, bent nails in two and a wrong size of the implant in one; secondary loss of reduction was found in three cases, with two cases of radius shortening and one 10°malrotation. No primary malrotation was recorded, but secondary loss of alignment was seen in the distal part of the radius and the proximal part of the ulna. Functional results according to the Anderson criteria were excellent and good in 87% of the cases. Intramedullary mailing provides good stability to mid- and distal-third shaft fractures of the ulna and mid- and proximalthird shaft fractures of the radius, particularly in AO type A and type B fractures. The technical aspects of the method are analysed in detail in this paper

  18. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  19. Are distal radius fractures due to fragility or to falls? A consecutive case-control study of bone mineral density, tendency to fall, risk factors for osteoporosis, and health-related quality of life.

    Science.gov (United States)

    Nordvall, Helena; Glanberg-Persson, Gunhild; Lysholm, Jack

    2007-04-01

    A fracture of the distal radius is considered to indicate an increased risk of future fractures, especially a hip fracture. The main causes may be osteoporosis or a tendency to fall, separately or in combination. 93 women and 5 men with a recent radius fracture and the same number of controls were measured with a heel-DXL and asked to complete one questionnaire on their quality of life (SF-36), and one on risk factors. The mean T-score of the patients was -2.1, and for the controls it was -1.9 (p = 0.3). The patients aged over 64 years had a history of falling more often than the corresponding controls (p = 0.01), but there was no difference in T-score. By contrast, patients 45-64 years of age showed a non-significant, lower T-score (p = 0.09), but there was no difference concerning their history of falling. For all other risk factors, no differences were found between the patients and the controls. There were significant differences between the patients and the controls in some of the functions in the SF-36, due to the radius fracture. This study indicates that the underlying cause of a distal radius fracture may be different in patients aged 45-64 years and those who are more than 64 years old.

  20. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  1. Outcome of management of distal radius fractures in ...

    African Journals Online (AJOL)

    Background and Purpose: Distal radial fractures are common fractures of postmenopausal age group patients. They are often called fractures of osteoporosis. These fractures are considered to be one of the commonest minor injuries to cause major morbidity in the community. A lot of patient who need surgery, fail to afford ...

  2. Bone density of the radius, spine, and proximal femur in osteoporosis

    International Nuclear Information System (INIS)

    Mazess, R.B.; Barden, H.; Ettinger, M.; Schultz, E.

    1988-01-01

    Bone mineral density (BMD) was measured in 140 normal young women (aged 20 to 39 years) and in 423 consecutive women over age 40 referred for evaluation of osteoporosis. Lumbar spine and proximal femur BMD was measured using dual-photon absorptiometry ( 153 Gd), whereas the radius shaft measurement used single-photon absorptiometry ( 125 I). There were 324 older women with no fractures, of which 278 aged 60 to 80 years served as age-matched controls. There were 99 women with fractures including 32 with vertebral and 22 with hip fractures. Subsequently, another 25 women with hip fractures had BMD measured in another laboratory; their mean BMD was within 2% of that of the original series. The mean age in both the nonfracture and fracture groups was 70 +/- 5 years. The BMD in the age-matched controls was 20% to 25% below that of normal young women for the radius, spine, and femur, but the Ward's triangle region of the femur showed even greater loss (35%). The mean BMD at all sites in the crush fracture cases was about 10% to 15% below that of age-matched controls. Spinal abnormality was best discriminated by spine and femoral measurements (Z score about 0.9). In women with hip fractures, the BMD was 10% below that of age-matched controls for the radius and the spine, and the BMD for the femoral sites was about 25% to 30% below that of age-matched control (Z score about 1.6). Femoral densities gave the best discrimination of hip fracture cases and even reflected spinal osteopenia. In contrast, neither the spine nor the radius reflected the full extent of femoral osteopenia in hip fracture

  3. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  4. Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Christersson, Albert; Larsson, Sune [Uppsala University, Department of Orthopaedics, Uppsala (Sweden); Nysjoe, Johan; Malmberg, Filip; Sintorn, Ida-Maria; Nystroem, Ingela [Uppsala University, Centre for Image Analysis, Uppsala (Sweden); Berglund, Lars [Uppsala University, Uppsala Clinical Research Centre, UCR Statistics, Uppsala (Sweden)

    2016-06-15

    The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4 , ± 1.9 and ± 6.8 respectively. For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested. (orig.)

  5. Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery.

    Science.gov (United States)

    Magaraggia, Jessica; Wei, Wei; Weiten, Markus; Kleinszig, Gerhard; Vetter, Sven; Franke, Jochen; John, Adrian; Egli, Adrian; Barth, Karl; Angelopoulou, Elli; Hornegger, Joachim

    2017-01-01

    During a standard fracture reduction and fixation procedure of the distal radius, only fluoroscopic images are available for planning of the screw placement and monitoring of the drill bit trajectory. Our prototype intra-operative framework integrates planning and drill guidance for a simplified and improved planning transfer. Guidance information is extracted using a video camera mounted onto a surgical drill. Real-time feedback of the drill bit position is provided using an augmented view of the planning X-rays. We evaluate the accuracy of the placed screws on plastic bones and on healthy and fractured forearm specimens. We also investigate the difference in accuracy between guided screw placement versus freehand. Moreover, the accuracy of the real-time position feedback of the drill bit is evaluated. A total of 166 screws were placed. On 37 plastic bones, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text] in tip position and orientation (azimuth and elevation), respectively. On the three healthy forearm specimens, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text]. On the two fractured specimens, we attained: [Formula: see text] mm, [Formula: see text] and [Formula: see text]. When screw plans were applied freehand (without our guidance system), the achieved accuracy was [Formula: see text] mm, [Formula: see text], while when they were transferred under guidance, we obtained [Formula: see text] mm, [Formula: see text]. Our results show that our framework is expected to increase the accuracy in screw positioning and to improve robustness w.r.t. freehand placement.

  6. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    Science.gov (United States)

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted

  7. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    Science.gov (United States)

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  8. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    Science.gov (United States)

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group

  9. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    Science.gov (United States)

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P0.05). The effective rate of swelling regression in electrical physical therapy group, western medicine group and the control group were 86.67%, 80.00%, 46.66% respectively. There was no

  10. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  11. [Case-control study on tibetan Baimai ointment (see symbol in text) for the treatment of wrist-dysfunction after distal radius fracture].

    Science.gov (United States)

    Zhang, Xing-ping; Xu, Gen-rong; Xu, Shan-qiang; Lu, Ze-ming; Huang, Lei

    2014-11-01

    To evaluate efficacy and safety of Baimai ointment (see symbol in text) in the treatment of wrist-dysfunction after distal radius fracture. From April, 2011 to June, 2012, 43 patients with distal radius fracture were treated with plaster fixation. All the patients were divided into two group: test group and control group. Twenty-one patients in test group and 22 in control group, and the baseline was balance (P > 0.05). The 21 patients in test group were treated with Baimai ointment (see symbol in text), fomentation, functional exercises. The 22 patients in control group were treated with placebo, fomentation, functional exercises. Foment affected side wrist with wet towel in 20 min before medication, with the temperature between 50 degrees C and 60 degrees C. Smear drugs uniformly in range of 3 cm in the vicinity of palm stripes after drying (about 3 g) and take functional exercises for the activities of wrist and hand. Continuous follow the program per 8 hours once and follow-up for 8 weeks. The Wrist's pain was assessed with VAS. The wrist's activities were measured with the protractor of orthopedic. Measure The grip strength was measured with dynamometer. The wrist's function were assessed with the table of Cooney. The test group had a significantly better results than those of control group in the extent of wrist's pain throughout the treatment (P 0.05). There were no drug adverse reactions occurred. Tibetan Baimai ointment (see symbol in text) has the treatment of wrist-dysfunction after distal radius fracture for external use, which can reduce the extent of wrist's pain, promote grip strength recovery in the middle and late of process, promote wrist's function recovery latterly, and safety for external use.

  12. Arthroscopy-Assisted Reduction and Fixation of a Transversal Glenoid Fracture: About a Case

    Directory of Open Access Journals (Sweden)

    David Zbili

    2017-01-01

    Full Text Available An articular glenoid fracture is an uncommon injury. Usually significantly displaced intra-articular glenoid fractures are treated with open reduction surgery. Conventional open surgery techniques involve high morbidity. Here we describe an arthroscopy-assisted reduction and fixation method of an Ideberg type III glenoid fracture. This method provides good articular reduction without extensive exposure or soft tissue dissection and without nerve and/or vascular lesion.

  13. Influence of side-groove root radius on the ductile fracture toughness of miniature C(T) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.

    2009-05-15

    The use of miniature C(T) specimens, MC(T), for fracture toughness measurements in the upper shelf regime has been investigated at SCK-CEN since 2004, in the framework of the Electrabel/Tractebel SCK-CEN Convention (now General Framework Agreement SUEZ-SCK-CEN). This geometry has been used and validated on both unirradiated (2004-05) and irradiated (2006) materials, mainly reactor pressure vessel (RPV) steels. While side-grooved MC(T) specimens have shown in all conditions a systematically lower tearing resistance and ductile crack initiation toughness as compared to standard-size 1TC(T) samples, the only plain-sided MC(T) specimen tested in 2005 exhibited very high ductile fracture toughness, thus pointing at a strong influence of side-grooving on the upper shelf properties of MC(T) specimens. This study investigates the influence of side-grooving on the initiation toughness and tearing resistance of MC(T) specimens, as a function of the root radius of the side-groove (ranging from 0.1 to 1 mm) and in comparison with plain-sided MC(T) and reference 1TC(T) samples. The material used is the well characterized DIN 22NiMoCr37 RPV steel, which had been used in the European project which generated the famous EURO fracture toughness data set.

  14. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    Science.gov (United States)

    Shin, Sang-Jin; Sohn, Hoon-Sang; Do, Nam-Hoon

    2012-10-01

    To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. : Prospective clinical series study. University hospital. Twenty-one patients with acute displaced humeral shaft fractures were treated by MIPO with a modified fracture reduction technique. A narrow 4.5/5.0-mm locking compression plate was applied to the anterior aspect of the humerus. Fracture reduction and manipulation were performed using a plate and drill bits. The operating time, time to union, humeral alignment, and functional outcome of the shoulder and elbow joints were evaluated using the University of California Los Angeles shoulder score and Mayo elbow performance score. No patient experienced a neurological complication. Bony union was obtained in 20/21 patients at a mean 17.5 weeks postoperatively. Eighteen patients had excellent and 3 patients had good results in the University of California Los Angeles score. The average Mayo elbow performance score was 97.5. Two patients were converted to an open reduction during operation due to a failure of MIPO. There was 1 nonunion and 1 malunion in this series. Although the MIPO technique for humeral shaft fractures is technically demanding, satisfactory clinical outcomes in terms of bony union and shoulder and elbow function can be obtained using the modified fracture reduction method. Potential postoperative complications, such as malreduction and nonunion, must be considered. Appropriate surgical indications, a thorough understanding of the neurovascular anatomy and skillful surgical technique, are needed to reduce potential complications.

  15. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    Science.gov (United States)

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  16. Changes in Depression, Health Anxiety, and Pain Catastrophizing Between Enrollment and 1 Month After a Radius Fracture.

    Science.gov (United States)

    Golkari, Sina; Teunis, Teun; Ring, David; Vranceanu, Ana-Maria

    2015-01-01

    To test the difference in symptoms of (1) depression, (2) health anxiety, and (3) catastrophic thinking between 1 and 6 weeks after injury to the radius. In total, 69 adult patients with a minimally displaced radial head or distal radius fracture were prospectively enrolled. After diagnosis, we recorded demographic variables, 11-point ordinal numerical pain score, and agreement with "no pain, no gain"; Disabilities of the Arms, Shoulder, and Hand (DASH) questionnaire; Center for Epidemiologic Studies Depression Scale; the Whiteley Index; and the Pain Catastrophizing Scale. In total, 55 patients (80%) returned after 1 month to reevaluate pain, Disabilities of the Arms, Shoulder, and Hand, Center for Epidemiologic Studies Depression, Whiteley Index, and Pain Catastrophizing Scale scores. Center for Epidemiologic Studies Depression scores decreased by an average of 5 ± 9 points (p psychologic measures are used as a screening tool to predict outcome after treatment, one should account for a patient's disease phase. Prognostic level I. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  17. Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

    Directory of Open Access Journals (Sweden)

    Yewon Lee

    2014-11-01

    Full Text Available BackgroundFrontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures.MethodsBetween March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws.ResultsContour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed.ConclusionsThe subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

  18. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  19. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  20. [An improved reduction technique for depression fractures of lateral tibial plateau].

    Science.gov (United States)

    Wang, Hongchuan; Lou, Hua; Liu, Kai; Jiang, Junwei

    2013-01-01

    To investigate the improved reduction technique for depression fractures of the lateral tibial plateau and its effectiveness. Between January 2008 and December 2010; 48 patients (48 knees) with depression fractures of the lateral tibial plateau (Schatzker II or III fractures) were treated. There were 32 males and 16 females with an average age of 45.8 years (range, 16-79 years). All fractures were fresh closed fractures, which were caused by traffic accident in 27 cases, by falling from height in 5 cases, by crushing in 8 cases, and by sustained falls in 8 cases. According to Schatzker classification, 29 cases were classified as type II and 19 cases as type III. The lateral cortex was cut off to expose the depression and compacted cancellous bone was elevated to reset the articular surface. After reduction, autologous iliac bone graft and locking plate internal fixation were used. Healing of incision by first intention was achieved in all patients, and no complication occurred. All patients were followed up 1.7 years on average (range, 1-3 years). At last follow-up, the knee extension was (-0.5 +/- 0.3) degrees, and the knee flexion was (136.9 +/- 8.8) degrees. X-ray films showed that the fracture healing time was 52 weeks and no breakage of internal fixation occurred. According to Rasmussen clinical score, the results were excellent in 35 cases, good in 10 cases, and fair in 3 cases. According to Rasmussen radiographical score, the results were excellent in 41 cases, good in 7 cases; there were 41 excellent scores and 7 good scores of articular reduction; all gained good recovery of coronal and sagittal alignment and condylar width. The articular surface collapse was (1.0 +/- 0.7) mm at immediate postoperatively and (1.2 +/- 0.7) mm at last follow-up, showing no significant difference (t = -1.42, P = 0.20), but significant differences were found when compared with that at preoperation [(12.2 +/- 8.0) mm, P fracture reduction and can avoid loss of reduction. The

  1. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available In the treatment of mandibular condyle fracture, conservative treatment using closedreduction or surgical treatment using open reduction can be used. Management of mandibularcondylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma.For each type of condylar fracture,the treatment method must be chosen taking intoconsideration the presence of teeth, fracture height, patient’sadaptation, patient’s masticatorysystem, disturbance of occlusal function, and deviation of the mandible. In the past, closedreduction with concomitant active physical therapy conducted after intermaxillary fixationduring the recovery period had been mainly used, but in recent years, open treatment ofcondylar fractures with rigid internal fixation has become more common. The objectiveof this review was to evaluate the main variables that determine the choice of an open orclosed method for treatment of condylar fractures, identifying their indications, advantages,and disadvantages, and to appraise the current evidence regarding the effectiveness ofinterventions that are used in the management of fractures of the mandibular condyle.

  2. Complications and functional outcome after internal fixation of dorsally displaced distal radial fractures

    DEFF Research Database (Denmark)

    Bove, Jeppe; Viberg, Bjarke; Wied Greisen, Pernille

    Background: Recently there has been an increasing interest in open reduction and internal fixation of distal radius fractures. Even so further studies are still needed. Purpose: To document the functional outcome and identify complica- tions among patients treated with a volar locking plate (DVR...

  3. [Frequency of diagnosis of postmenopausal osteoporosis of the spine, distant radius and extravertebral fractures in women with normal body mass, overweight and obesity].

    Science.gov (United States)

    Popov, A A; Izmozherova, N V; Fominykh, M I; Tagil'tseva, N V; Kozulina, E V; Gavrilova, E I

    2008-01-01

    To assess features and peculiarities of postmenopausal osteoporosis (OP) in women with normal body mass, overweight and obesity. Dual energy X-ray absorptiometry of the lumbal spine (Lunar DPX) and distal radius X-ray absorptiometry (DTX 200) were performed during cross-section study of 730 symptomatic postmenopausal women. OP was diagnosed in 253 (34.7%) women, 30.5% of them had normal body mass, 43.2% had overweight and 26.3% were obese. Among them 227 had atraumatic fractures at the age over 50 years. Obese OP patients had significantly higher frequency of arterial hypertension, chronic heart failure, osteoarthritis and glucose metabolism disorders than osteoporotic patients with normal body mass. Fracture frequency did not differ between groups with normal body mass, overweight and obesity. Excessive body mass did not decrease fracture risk in women with postmenopausal OP.

  4. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw.

    Science.gov (United States)

    Baek, Ji Eun; Chung, Chan Min; Hong, In Pyo

    2012-09-01

    Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

  5. Three-dimensional assessment of unilateral subcondylar fracture using computed tomography after open reduction

    Directory of Open Access Journals (Sweden)

    Sathya Kumar Devireddy

    2014-01-01

    Full Text Available Objective: The aim was to assess the accuracy of three-dimensional anatomical reductions achieved by open method of treatment in cases of displaced unilateral mandibular subcondylar fractures using preoperative (pre op and postoperative (post op computed tomography (CT scans. Materials and Methods: In this prospective study, 10 patients with unilateral sub condylar fractures confirmed by an orthopantomogram were included. A pre op and post op CT after 1 week of surgical procedure was taken in axial, coronal and sagittal plane along with three-dimensional reconstruction. Standard anatomical parameters, which undergo changes due to fractures of the mandibular condyle were measured in pre and post op CT scans in three planes and statistically analysed for the accuracy of the reduction comparing the following variables: (a Pre op fractured and nonfractured side (b post op fractured and nonfractured side (c pre op fractured and post op fractured side. P < 0.05 was considered as significant. Results: Three-dimensional anatomical reduction was possible in 9 out of 10 cases (90%. The statistical analysis of each parameter in three variables revealed (P < 0.05 that there was a gross change in the dimensions of the parameters obtained in pre op fractured and nonfractured side. When these parameters were assessed in post op CT for the three variables there was no statistical difference between the post op fractured side and non fractured side. The same parameters were analysed for the three variables in pre op fractured and post op fractured side and found significant statistical difference suggesting a considerable change in the dimensions of the fractured side post operatively. Conclusion: The statistical and clinical results in our study emphasised that it is possible to fix the condyle in three-dimensional anatomical positions with open method of treatment and avoid post op degenerative joint changes. CT is the ideal imaging tool and should be used on

  6. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs.

    Science.gov (United States)

    Cummings, Steven R; Karpf, David B; Harris, Fran; Genant, Harry K; Ensrud, Kristine; LaCroix, Andrea Z; Black, Dennis M

    2002-03-01

    To estimate how much the improvement in bone mass accounts for the reduction in risk of vertebral fracture that has been observed in randomized trials of antiresorptive treatments for osteoporosis. After a systematic search, we conducted a meta-analysis of 12 trials to describe the relation between improvement in spine bone mineral density and reduction in risk of vertebral fracture in postmenopausal women. We also used logistic models to estimate the proportion of the reduction in risk of vertebral fracture observed with alendronate in the Fracture Intervention Trial that was due to improvement in bone mineral density. Across the 12 trials, a 1% improvement in spine bone mineral density was associated with a 0.03 decrease (95% confidence interval [CI]: 0.02 to 0.05) in the relative risk (RR) of vertebral fracture. The reductions in risk were greater than predicted from improvement in bone mineral density; for example, the model estimated that treatments predicted to reduce fracture risk by 20% (RR = 0.80), based on improvement in bone mineral density, actually reduce the risk of fracture by about 45% (RR = 0.55). In the Fracture Intervention Trial, improvement in spine bone mineral density explained 16% (95% CI: 11% to 27%) of the reduction in the risk of vertebral fracture with alendronate. Improvement in spine bone mineral density during treatment with antiresorptive drugs accounts for a predictable but small part of the observed reduction in the risk of vertebral fracture.

  8. Closed treatment of overriding distal radial fractures without reduction in children.

    Science.gov (United States)

    Crawford, Scott N; Lee, Lorrin S K; Izuka, Byron H

    2012-02-01

    Traditionally, distal radial fractures with marked displacement and angulation have been treated with closed or open reduction techniques. Reduction maneuvers generally require analgesia and sedation, which increase hospital time, cost, patient risk, and the surgeon's time. In our study, a treatment protocol for pediatric distal radial fractures was used in which the fracture was left shortened in an overriding position and a cast was applied without an attempt at anatomic fracture reduction. Consecutive patients three to ten years of age presenting between 2004 and 2009 with a closed overriding fracture of the distal radial metaphysis were followed prospectively. Our protocol consisted of no analgesia, no sedation, and a short arm fiberglass cast gently molded to correct only angulation. Patients were followed for at least one year. All parents or guardians were given a questionnaire assessing their satisfaction with the treatment. Financial analysis was performed with use of Current Procedural Terminology codes and the average total cost of care. Fifty-one children with an average age of 6.9 years were included in the study. Initial radial shortening averaged 5.0 mm. Initial sagittal and coronal angulation averaged 4.0° and 3.2°, respectively. The average duration of casting was forty-two days. Residual sagittal and coronal angulation at the time of final follow-up averaged 2.2° and 0.8°, respectively. All fifty-one patients achieved clinical and radiographic union with a full range of wrist motion. All parents and guardians answered the questionnaire and were satisfied with the treatment. Cost analysis demonstrated that closed reduction with the patient under conscious sedation or general anesthesia is nearly five to six times more expensive than the treatment used in this study. Adding percutaneous pin fixation increases costs nearly ninefold. This treatment protocol presents an alternative approach to overriding distal radial fractures in children and

  9. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.

    Science.gov (United States)

    Gary, Joshua L; Munz, John W; Burgess, Andrew R

    2014-06-01

    Eccentric reaming of cortical bone near a fracture site can introduce malalignment when an intramedullary nail is placed. The authors describe a technique of reaming metadiaphyseal and diaphyseal femur fractures in which maintaining reduction at the fracture site is not necessary to obtain an excellent alignment of long bone fractures after intramedullary nailing. They have found that central reaming proximal and distal to, but not at, the fracture site allows for excellent reduction of long bone fractures when the intramedullary nail is passed. The reamer is stopped just before the fracture site and then "pushed" across the fracture prior to resumption of reaming. The authors present "push-past" reaming as a technical trick to facilitate reduction of femoral fractures treated with intramedullary nails and a consecutive series of 18 cases in which excellent postoperative alignment was achieved. Copyright 2014, SLACK Incorporated.

  10. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  11. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    Science.gov (United States)

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  12. Linear intra-bone geometry dependencies of the radius: Radius length determination by maximum distal width

    International Nuclear Information System (INIS)

    Baumbach, S.F.; Krusche-Mandl, I.; Huf, W.; Mall, G.; Fialka, C.

    2012-01-01

    Purpose: The aim of the study was to investigate possible linear intra-bone geometry dependencies by determining the relation between the maximum radius length and maximum distal width in two independent populations and test for possible gender or age effects. A strong correlation can help develop more representative fracture models and osteosynthetic devices as well as aid gender and height estimation in anthropologic/forensic cases. Methods: First, maximum radius length and distal width of 100 consecutive patients, aged 20–70 years, were digitally measured on standard lower arm radiographs by two independent investigators. Second, the same measurements were performed ex vivo on a second cohort, 135 isolated, formalin fixed radii. Standard descriptive statistics as well as correlations were calculated and possible gender age influences tested for both populations separately. Results: The radiographic dataset resulted in a correlation of radius length and width of r = 0.753 (adj. R 2 = 0.563, p 2 = 0.592) and side no influence on the correlation. Radius length–width correlation for the isolated radii was r = 0.621 (adj. R 2 = 0.381, p 2 = 0.598). Conclusion: A relatively strong radius length–distal width correlation was found in two different populations, indicating that linear body proportions might not only apply to body height and axial length measurements of long bones but also to proportional dependency of bone shapes in general.

  13. It is not just comfort: waterproof casting increases physical functioning in children with minimally angulated distal radius fractures.

    Science.gov (United States)

    Silva, Mauricio; Avoian, Tigran; Warnock, Robert Sean; Sadlik, Gal; Ebramzadeh, Edward

    2017-09-01

    Waterproof casting has been reported to increase patient comfort and satisfaction, and decrease skin irritation. There are no available data on the influence of waterproof casting materials on physical function in pediatric patients. Our aim was to determine whether the use of waterproof casting would result in faster recovery of physical function while maintaining similar clinical outcomes as those obtained with nonwaterproof materials. Twenty-six children with nonangulated or minimally angulated distal radius fractures were assigned randomly to initially receive a short-arm cast made of one of two optional materials: a hybrid mesh material with a waterproof lining or fiberglass with a nonwaterproof skin protector. Two weeks later, the initial cast was removed and replaced with a short-arm cast made of the alternative option. We compared the rate of fracture displacement, physical function, pain, skin changes, itchiness, and patient satisfaction. No evidence of displacement was found in either group. The mean Activities Scale for Kids - Performance (ASK-P) (physical function) score was 10% higher during the period of time when a waterproof cast was used (P=0.04). When a waterproof cast was used during the first 2 weeks of treatment, the mean total ASK-P scores were 23% higher than that when a nonwaterproof one was used during the same period of time (P=0.003). Patients who received a waterproof cast as the initial treatment reported lower functional scores overall and in almost every domain of the ASK-P once they were in a nonwaterproof one; similarly, those who received a nonwaterproof cast as the initial treatment reported higher functional scores overall and in every domain of the ASK-P once they were in a waterproof cast. Compared with a nonwaterproof cast, the use of waterproof casting resulted in comparable levels of pain, itchiness, skin irritability, and overall patient satisfaction. The results of this randomized, cross-over trial suggest that the use of

  14. Recommendation for measuring clinical outcome in distal radius fractures: a core set of domains for standardized reporting in clinical practice and research.

    Science.gov (United States)

    Goldhahn, Jörg; Beaton, Dorcas; Ladd, Amy; Macdermid, Joy; Hoang-Kim, Amy

    2014-02-01

    Lack of standardization of outcome measurement has hampered an evidence-based approach to clinical practice and research. We adopted a process of reviewing evidence on current use of measures and appropriate theoretical frameworks for health and disability to inform a consensus process that was focused on deriving the minimal set of core domains in distal radius fracture. We agreed on the following seven core recommendations: (1) pain and function were regarded as the primary domains, (2) very brief measures were needed for routine administration in clinical practice, (3) these brief measures could be augmented by additional measures that provide more detail or address additional domains for clinical research, (4) measurement of pain should include measures of both intensity and frequency as core attributes, (5) a numeric pain scale, e.g. visual analogue scale or visual numeric scale or the pain subscale of the patient-reported wrist evaluation (PRWE) questionnaires were identified as reliable, valid and feasible measures to measure these concepts, (6) for function, either the Quick Disability of the arm, shoulder and hand questionnaire or PRWE-function subscale was identified as reliable, valid and feasible measures, and (7) a measure of participation and treatment complications should be considered core outcomes for both clinical practice and research. We used a sound methodological approach to form a comprehensive foundation of content for outcomes in the area of distal radius fractures. We recommend the use of symptom and function as separate domains in the ICF core set in clinical research or practice for patients with wrist fracture. Further research is needed to provide more definitive measurement properties of measures across all domains.

  15. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    Science.gov (United States)

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Impact of Open Reduction on Surgical Strategies for Missed Monteggia Fracture in Children.

    Science.gov (United States)

    Park, Hoon; Park, Kwang Won; Park, Kun Bo; Kim, Hyun Woo; Eom, Nam Kyu; Lee, Dong Hoon

    2017-07-01

    The aims of this study were to review our cases of missed Monteggia fracture treated by open reduction of the radial head with or without ulnar osteotomy and to investigate the indications for open reduction alone in surgical treatment of missed Monteggia fracture. We retrospectively reviewed 22 patients who presented with missed Monteggia fracture. The patients' mean age at the time of surgery was 7.6 years. The mean interval from injury to surgery was 16.1 months. The surgical procedure consisted of open reduction of the radiocapitellar joint followed by ulnar osteotomy without reconstruction of the annular ligament. The mean period of follow-up was 3.8 years. Radiographic assessment was performed for the maximum ulnar bow (MUB) and the location of the MUB. Clinical results were evaluated with the Mayo Elbow Performance Index and Kim's scores. Five patients underwent open reduction alone, and 17 patients underwent open reduction and ulnar osteotomy. When the MUB was less than 4 mm and the location of the MUB was in the distal 40% of the ulna, we could achieve reduction of the radial head without ulnar osteotomy. The radial head was maintained in a completely reduced position in 21 patients and was dislocated in one patient at final follow-up. Open reduction alone can be an attractive surgical option in select patients with missed Monteggia fracture with minimal bowing of the distal ulna. However, ulnar osteotomy should be considered in patients with a definite ulnar deformity. © Copyright: Yonsei University College of Medicine 2017

  17. Open versus closed reduction: diacapitular fractures of the mandibular condyle.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2012-09-01

    The purpose of the study was to review the literature regarding the evolution of current thoughts on management of diacapitular fractures (DFs) of the mandibular condyle. An electronic search in PubMed was undertaken in March 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies reporting clinical series of DFs, including both animal and human studies, without date or language restrictions. The search strategy initially yielded 108 references. Twenty-eight studies were identified without repetition within the selection criteria. Additional hand-searching of the reference lists of selected studies yielded three additional papers. The current indications for open reduction and internal fixation (ORIF) of DFs described in the literature are: (a) fractures affecting the lateral condyle with reduction of mandibular height; (b) fractures in which the proximal fragment dislocates laterally out of the glenoid fossa, which cannot be reduced by closed or open treatment of another part of the mandibular fracture. The indications for conservative treatment are: (a) fractures that do not shorten the condylar height (a fracture with displacement of the medial parts of the condyle); (b) undisplaced fractures; (c) comminution of the condylar head, when the bony fragments are too small for stable fixation; and (d) fractures in children. As the temporomandibular joint disk plays an important role as a barrier preventing ankylosis, it is important to reposition the disk (if displaced/dislocated) during the surgical treatment of DFs. The lateral pterygoid muscle should never be stripped from the medially displaced fragment because its desinsertion disrupts circulation to the medial bony fragment, and also because this muscle helps to restore the muscle function after surgery. ORIF of selected DFs improves prognosis by anatomical bone and soft tissue recovery when combined with physical

  18. Close reduction and per cutaneous pinning of supracondylar fractures of humerus in children

    International Nuclear Information System (INIS)

    Iqbal, S.; Maqbool, N.

    2014-01-01

    The purpose of this study was to assess outcome and complications associated with closed reduction and internal fixation of supracondylar fractures type III of humerus in children. Study Design: Quasi - experimental. Place and Duration of Study: Department of Orthopedics, Fauji Foundation Hospital Rawalpindi and Railway General Hospital (RGH), Rawalpindi, from June 2011 to August 2012. Material and Method: The study group included 16 boys and 8 girls aged 4-12 years with supracondyle Type III fractures of humerus, having no neurovascular injury and no appreciable edema. Relevant history and clinical details were taken. All those cases having any neurovascular injury or moderate to severe edema at elbow and presenting late more than two weeks were excluded. These cases were treated with closed reduction and internal fixation. Follow up was done for 6 months to assess the level of cosmetic and function according to the system described by Flynn's et al as excellent, good, fair and poor. Results: Study was completed on 24 patients (16 males and 8 females). All fractures were united in acceptable alignment. At final assessment there were 16 excellent, 5 good, 3 fair. No one was poor. The fair clinical outcome was higher in children above 10 years of age. Conclusion: Closed reduction and internal fixation with cast stabilization can provide precise and good fracture reduction, maintains stabilization for fracture healing, results in good cosmetic outcome, cost effective and facilitates easy removal of implants after treatment. (author)

  19. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  20. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  1. Occupational therapy and Colles' fractures.

    Science.gov (United States)

    Christensen, O M; Kunov, A; Hansen, F F; Christiansen, T C; Krasheninnikoff, M

    2001-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups at any time. It seems that for non-surgically treated patients with a distal radius fracture only instructions are necessary.

  2. Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures.

    Science.gov (United States)

    Siebenrock, K A; Müller, U; Ganz, R

    1998-01-01

    Subtrochanteric fractures frequently occur as high energy trauma usually in younger patients and may lead to severe comminution of the medial cortex. The medial cortex of the proximal femur is exposed to high compressive forces which make fracture stabilization a difficult problem. Bone healing may be seriously compromised due to extensive comminution and fragment devitalization. This requires reduction techniques which do not cause additional damage to the vitality of the bone. With indirect reduction techniques and the use of a condylar blade plate the results have been significantly improved in these fracture types in our department (1). In this report the essential aspects of indirect reduction for subtrochanteric fractures using a condylar blade plate and the treatment results from our department from earlier years (1) and from the last 2 1/2 years will be presented. In the latter period, fifteen patients with a mean age of 49 years (19-87 years) were treated with this method. Fractures resulted from traffic incidents or falls from a great height in 11 cases (73%). Union was achieved in 14 cases (93%) with full weight-bearing after a mean of 3 months (1-4 1/2 months). Malunion was seen in two cases (13%) without the need for further surgery. Non union occurred in one patient (7%) with a III B open injury due to early infection. After repeated debridements, bone grafting and decortication, the fracture was stabilized with a replacement condylar blade plate and healed uneventfully.

  3. Management of complications of open reduction and internal fixation of ankle fractures.

    Science.gov (United States)

    Ng, Alan; Barnes, Esther S

    2009-01-01

    The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.

  4. Testing the validity of preventing chronic regional pain syndrome with vitamin C after distal radius fracture. [Corrected].

    Science.gov (United States)

    Malay, Sunitha; Chung, Kevin C

    2014-11-01

    The American Academy of Orthopaedic Surgeons recommends the use of vitamin C to prevent complex regional pain syndrome (CRPS) for patients with distal radius fractures (DRFs). We hypothesized that the evidence for supporting this recommendation is weak, based on epidemiological principles of association and causality. The specific aim of this project was to test the validity of this recommendation. We conducted a literature review to retrieve articles reporting on the use of vitamin C to prevent CRPS. Data collected included sample size, study design type, dose of vitamin C used, and outcome measures of association expressed as relative risk (RR) and odds ratio. We then applied Hill criteria to evaluate the relationship between vitamin C and CRPS. We obtained 225 articles from the database search. After the exclusion of duplicates, unrelated articles, editorial letters, and commentaries, we found 4 articles and 1 systematic review relevant to our topic. Six of the 9 Hill criteria were met, and an earlier meta-analysis showed a quantified reduction in CRPS risk. However, criteria like biological plausibility, specificity, and coherence were not met. The number of causal/association criteria met was adequate to support the scientific premise of the effect of vitamin C in preventing CRPS after DRF. Furthermore, vitamin C administration is of relatively low cost and has few complications unless administered in large doses. Owing to sufficient epidemiological evidence availability, the American Academy of Orthopaedic Surgeons recommendation of vitamin C to prevent CRPS has practical merit. Therapeutic II. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    incisions for radius and ulna and preservation of the natural curves of radius will lessen the rate of complications. Rigid fixation of fractures after perfect anatomical reduction with 3.5 mm DCP and screws allows early mobilisation, prevents soft tissue contracture, muscular tethering and improves vascularity. A minimum of 6 cortices have to be fixed in each fracture fragment and the nearest screw to the fracture line should be at least 1 cm away. It minimises vascular damage to the plated bone segment.

  6. The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

    Directory of Open Access Journals (Sweden)

    Kaykhosro Mardanpour

    2011-07-01

    Full Text Available Background:Unstable Pelvic fracture,a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This study was performed to evaluate the functional and radiological results of treatment of pelvic ring fractures by open reduction, internal fixation. Methods: Thirty eight patients with unstable pelvic fractures, treated from 2002 to2008 were retrospectively reviewed. The mean age of patients’ was 37 years old (range 20 to 67. Twenty six patients were men and 12 women. The most common cause was a road traffic accident (N=37, 97%. There were 11 type-C and 27 type-B fractures according to Tile’s classification. Thirty six patients sustained additional injuries. The most prevalent additional injuries were lower extremity fractures. Open reduction, internal fixation as a definite management was applied for all patients. Quality of reduction was graded according to the grades proposed by Matta and Majeed’s score was used to assess the clinical outcome. The mean period of follow-up was 25 months (ranged from 6 to 109 months. About 81.6% of patients had either good or excellent radiological reduction. Results: The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients. There were 4 postoperative infections. No sexual function problem was reported. Nerve deficits recovered completely in 2 and partially in 3 of 11 patients with preoperative neurologic deficiency. There was no significant relation between functional outcome and the site of fracture Conclusion: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization that must be carried out as soon as the general ndition of the patient permits, and

  7. A PROSPECTIVE STUDY OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN TREATED BY CLOSED REDUCTION

    Directory of Open Access Journals (Sweden)

    Ch. Imobi

    2015-08-01

    Full Text Available There is no universal agreement regarding the management of displaced supracondylar fracture of the humerous in children. According to some orthopaedic surgeon almost all supracondylar humeral fractures should be treated operatively by reduction and pinning. While according to others closed reduction and pinning should be used for Gartland type II and some type III fractures. We present 50 cases of displaced supracondylar fracture treated by closed manipulative reduction under G.A. and immobilization with a posterior plaster of paris slab and collar and cuff. OBJECTIVE : T o assess the functional results of the injured elbow and to study the incidence of change in the carrying angle of the elbow. MATERIALS AND METHODS: This prospective study was conducted in 50 patients with extension type of displaced supracondylar fractures of humerus in children (Gartland type II and type III treated by closed manipulative reduction and immobilization in flexion of the elbow with a posterior plaster of paris slab and collar and cuff. Patients were followed up for 6 months. Flexion type of supracondylar fracture and those fractures which are absolutely indicated for operative intervention, Viz an open fracture and severe vascular compromise were excluded from the study. The range of movement and carrying angle was measured with the help of a Goniometer and Flynn criteria were used for functional assessment. RESULTS: At the end of follow up period, the end results were graded as excellent in 40%, good in 42%, fair in 12% and poor in 6%. A satisfactory result was therefore obtained in 94% and unsatisfactory result in 6% of the 50 patients who were followed and evaluated. CONCLUSION: This closed method of treatment for all practical proposes produces least complications, shorter hospital stay, can be expected to yield reproducible consistent satisfactory results not surpassed by any other method of treatment.

  8. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  9. Perbandingan Fungsi Extremitas Atas pada Fraktur Metafise Distal Radius Intraartikuler Usia Muda Antara Tindakan Operatif Dan Non Operatif dengan Penilaian Klinis Quickdash Score

    Directory of Open Access Journals (Sweden)

    Edi Burhan

    2014-01-01

    Full Text Available AbstrakFraktur metafise distal radius merupakan fraktur dengan insiden tertinggi kedua pada usia tua di luar fraktur daerah panggul. Di Rumah Sakit Dr. M. Djamil Padang terdapat 122 dari 612 kasus fraktur radius, antara Januari 2011 – Juni 2012. Tujuan utama terapi ini adalah pengembalian permukaan sendi ke posisi anatomis dengan fiksasi yang stabil dan pengembalian fungsi extremitas atas semaksimal mungkin. Metode: Penelitian ini berupa penelitian retrospektif yang dilakukan di poliklinik orthopaedi RSUP Dr M Djamil Padang pada bulan November-Desember 2012 pada pasien fraktur metafise distal radius intraartikuler usia muda yang mendapat tindakan operatif dibandingkan dengan kelompok non-operatif dengan penilaian klinis Quick DASH Score. Sampel yang digunakan sebanyak 30 orang dari 55 orang yang memenuhi kriteria inklusi. Hasil: Ada hubungan yang bermakna antara fungsi extremitas atas dengan penilaian Quick DASH Score antara tindakan operatif pada fraktur distal radius intraartikuler usia muda dengan tindakan non-operatif (p Fisher = 0,010. Tidak terdapat hubungan bermakna antara Quick DASH Score dengan jenis kelamin dan diagnosa kanan atau kiri. Pembahasan: Terdapat perbedaan yang bermakna antara pasien fraktur metafise distal radius intraartikuler pada usia muda yang mendapat tindakan operatif berupa ORIF dengan yang mendapatkan tindakan non-operatif berupa pemasangan Gips.Kata kunci: Fraktur Metafise Distal Radius, Tindakan Operatif dan Non Operatif, Quick Dash ScoreAbstractFracture metafise distal radius is fracture with second highest incident on old age besides a fracture in the pelvic area. In the Dr. M. Djamil Hospital found 122 from 612 cases fracture of radius from january 2011 to june 2012. The main purpose therapy is restore the joint in the surface position anatomically by fixation a stable and restore the function upper extremitas over their best. Method: This study is a retrospective conducted at the Orthopaedi clinic of Dr M

  10. Consequences of quality of reduction on osteosynthesis complications and quality of life in elderly patients with subtrochanteric fracture.

    Science.gov (United States)

    Codesido-Vilar, P; Mejía-Casado, A; Riego-Fernández, J; Rodriguez-Casas, N; García-Cabanas, S; Rivas-Felice, J; García-Quevedo, L

    2018-05-18

    To compare results in terms of orthopaedic complications and quality of life in elderly patients with subtrochanteric fracture treated with intramedullary nailing according to fracture reduction status. A prospective cohort study including 90 elderly patients with subtrochanteric fractures of the femur treated with a cephalomedullary nail, with a minimum 1-year follow up. The inclusion criteria were: aged 60 years or older, without severe cognitive dysfunction and independent ambulatory capability before the fracture. We defined 3different groups in relation to fracture reduction status: good, acceptable and poor, according to modified criteria from Baumgartner et al. We compared clinical and surgical characteristics and healthy quality of life, social function and mobility according to the EQ-5D, Jensen Index and Mobility Score of Parker and Palmer questionnaires. We found differences in time to union, better in the good reduction group (P=.002); need for open reduction, more frequent in the good reduction group (P<.001), and in postoperative complications, more frequent in the poor reduction group (P=.001). We found no significant differences between the 3groups regarding scores in quality of life, social function and mobility. Reduction in subtrochanteric fractures in older people is key to obtaining better clinic and surgical results, improving time to union and decreasing surgical complications. Exposure of the focus fracture seems to be a safe manoeuvre. Quality of life had substantially deteriorated n these patients, but a there was a tendency, although not statistically significant, for it to improve in patients after good surgical reduction. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Do instability markers predict satisfactory reduction and requirement for later surgery in emergency department patients with wrist fracture?

    Science.gov (United States)

    Winayak, Amar; Gossat, Alyza; Cooper, Jenny; Ritchie, Peter; Lim, Wei; Klim, Sharon; Kelly, Anne-Maree

    2018-02-01

    Research suggests that the presence of instability markers in patients with displaced distal radial fractures is associated with poorer outcome. Our aims were to determine whether the presence of previously defined instability markers could predict the likelihood of successful ED reduction and requirement for a secondary procedure after ED reduction. Retrospective cohort study performed by medical record review. Adult ED patients coded as having an isolated wrist fracture and having fracture reduction in ED were eligible for inclusion. Data collected included demographics, history of osteoporosis, mechanism of injury, radiological features on X-rays and performance of a secondary procedure. Outcomes of interest were the rate of successful fracture reduction in ED (against defined radiological criteria), the rate of secondary procedures and the association between the number of defined instability risk factors and successful reduction and performance of a secondary surgical procedure. Analysis was by χ 2 test, receiver operating characteristic curve, logistic regression analyses. Three hundred and nineteen patients were studied; median age 62 years, 77% female. Sixty-five per cent of patients had satisfactory fracture reduction in ED (95% CI 59%-70%). Eighty-six patients underwent a secondary procedure to reduce/stabilise their fracture (28%, 95% CI 23%-33%). Younger age, lack of satisfactory ED reduction and increased number of instability factors were independently predictive of the performance of a secondary procedure. Instability risk factors are common in patients with wrist fractures requiring reduction in ED. The number of instability factors is not a strong predictor of the performance of secondary procedures. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  12. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  13. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  14. Minimal packing duration in close reduction for nasal bone fracture treatment.

    Science.gov (United States)

    Choi, Dong Sik; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae; Choi, Kang Young

    2015-04-15

    Nasal bone fracture is the most common type of facial bone fracture. The optimal duration of the packing after closed reduction has been a controversial issue. The packing has several disadvantages such as blocking the nasal airway, causing infection and a headache, which is the most common immediate complication. The present study investigated the minimal and optimal duration of the nasal packing following reduction surgery of nasal bone fracture. A prospective study was performed for the patients undergoing reduction surgery following nasal bone fracture between July 2010 and June 2012. The patients were categorised into three groups according to the duration of nasal packing. For the patients treated between July 2010 and June 2011, nasal packing was maintained for 5 days. For those between July 2011 and December 2011, packing was maintained for 3 days. For those between January 2012 and June 2012, the packing was removed after 1 day. The computed tomography scan and the cephalolateral X-ray were checked at immediate postoperative period after packing removal and 6 months postoperatively. The alteration of heights, deviations, and nasal bone contours with time passage were compared among three groups. The patient satisfaction survey was also performed and compared. A total of 530 patients including 322 of the 5-days packing group, 102 of the 3-days group, and 106 of the 1-day group were enrolled. There was no statistically significant difference between the groups in terms of heights, deviations, and nasal bone contours (p-value ≥ 0.05). In the patient satisfaction survey, the 1-day packing group complained of discomfort related to nasal packing and headache symptoms much less, compared to the other two groups. The present study demonstrated that 1-day packing had comparable postoperative outcome with reducing the patients' discomfort. As such, a longer packing duration was not needed to achieve stable results one day is a reasonable packing time for most

  15. Integration of computer-assisted fracture reduction system and a hybrid 3-DOF-RPS mechanism for assisting the orthopedic surgery

    Science.gov (United States)

    Irwansyah; Sinh, N. P.; Lai, J. Y.; Essomba, T.; Asbar, R.; Lee, P. Y.

    2018-02-01

    In this paper, we present study to integrate virtual fracture bone reduction simulation tool with a novel hybrid 3-DOF-RPS external fixator to relocate back bone fragments into their anatomically original position. A 3D model of fractured bone was reconstructed and manipulated using 3D design and modeling software, PhysiGuide. The virtual reduction system was applied to reduce a bilateral femoral shaft fracture type 32-A3. Measurement data from fracture reduction and fixation stages were implemented to manipulate the manipulator pose in patient’s clinical case. The experimental result presents that by merging both of those techniques will give more possibilities to reduce virtual bone reduction time, improve facial and shortest healing treatment.

  16. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs.

    Science.gov (United States)

    Watrous, Gwyneth K; Moens, Noel M M

    2017-04-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.

  17. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    Science.gov (United States)

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  18. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases.

    Science.gov (United States)

    St-Jean, G; Debowes, R M

    1992-04-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.At the time of injury, the calves ranged in age from one day to two months and weighed from 37-102 kg. Two fractures were comminuted and one was transverse. All fractures were closed. After surgery, all calves could walk within 24 hours. Radiographic and clinical evidence of fracture healing was present five to seven weeks (mean 6) after surgery. At that time, the pins and cast material were removed. Return to normal function was rapid and judged to be excellent at follow-up evaluation five to nine months later.Advantages of transfixation pinning and casting in management of radial-ulnar fractures include flexibility in pin positioning, adequate maintenance of reduction, early return to weight-bearing status, preservation of joint mobility, and ease of ambulation. The inability to adjust fixation and alignment after cast application is a disadvantage of this technique compared with other external fixators. We concluded that transfixation pinning is a useful means of stabilizing radial-ulnar fractures in pediatric bovine patients.

  19. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    Science.gov (United States)

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  20. [POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY].

    Science.gov (United States)

    Qu, Feng; Yuan, Bangtuo; Qi, Wei; Wang, Junliang; Shen, Xuezhen; Wang, Jiangtao; Zhao, Gang; Liu, Yujie

    2014-07-01

    To discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. Between January 2009 and January 2012, 9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment. Of 9 cases, 6 were men, and 3 were women, aged 21-54 years (mean, 39 years). The causes were traffic accident injury in 7 cases, falling injury from height in 1 case, and hurt injury in 1 case. The shoulder abduction, flexion, and external rotation were obviously limited. X-ray films showed all cases had obvious displaced scapular neck fracture. Three-dimensional reconstruction of CT showed a grossly displaced of fracture. The time of injury to surgery was 4-27 days (mean, 11 days). Patients obtained healing of incision by first intension, without infection, neurovascular injury, or other surgery-related complications. All patients were followed up 19- 31 months (mean, 23 months). X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean, 8 weeks). At last follow-up, the shoulder abduction, flexion, and external rotation activity were improved significantly when compared with ones at preoperation (P shoulder Constant score, American Shoulder and Elbow Surgenos (ASES) score, and Rowe score were significantly better than preoperative scores (P shoulder stability and reduce complications.

  1. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    Science.gov (United States)

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  2. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  3. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    Science.gov (United States)

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at Pfractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  4. Non union of the neck of radius: a case report and review of the ...

    African Journals Online (AJOL)

    Fractures of the neck of radius are frequent in trauma. They happen without being noticed at the moment of injury of the elbow or in the context of polytrauma. A case of non union of the radius neck occurring in a young person due to ignorance, during first consultation has been reported by the authors. They insist on the ...

  5. Outcome after open reduction and internal fixation of intraarticular fractures of the calcaneum without the use of bone grafts

    Directory of Open Access Journals (Sweden)

    Pendse Aniruddha

    2006-01-01

    Full Text Available Background: Intraarticular fractures of calcaneum are commenest type of calcaneal fractures. Lots of controversies exist about the ideal management for them. The focus is now shifting on operative management by open reduction and internal fixation for these fractures with or without the use of bone grafts. Method: Thirty intraarticular fractures classified by Essex Lopresti radiological classification, were treated by open reduction and fixation. The patients were followed over a mean period of 30 months (25-40 months. Results: All the fractures united at a mean duration of 14 weeks. 86% patients had excellent functional outcome with one patient having fair and one having poor functional outcome. Conclusion: Open reduction and internal fixation with plate is a good method for treatment of intraarticular fractures of calcaneum to achieve anatomical restoration of articular surface under vision, stable fixation, early mobilization and an option for primary subtalar arthrodesis if deemed necessary.

  6. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  7. Closed reduction, internal fixation with quadratus femoris muscle pedicle bone grafting in displaced femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Chaudhuri Sibaji

    2008-01-01

    Full Text Available Background: Management of femoral neck fracture is still considered as an unsolved problem. It is more evident in displaced fractures where this fracture is considered as some sort of vascular insult to the head of the femur. We have used closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting in fresh displaced femoral neck fractures. Materials and Methods: From April 1996 to December 2004 we operated 73 consecutive patients of displaced femoral neck fracture in the age group of 24 to 81 years, mean age being 54.6 years. The patients were operated within one week of injury, the mean delay being 3.6 days. Closed reduction internal fixation along with quadratus femoris muscle pedicle bone grafting was done in all cases. They were followed up for an average period of 5.6 years (range 2-11 years. Results: Results were assessed according to modified Harris Hip Scoring system and found to be excellent in 53, good in 12, fair in six and poor in two patients. Bony union occurred in 68 cases, no patient developed avascular necrosis (AVN till date. Conclusion: For fresh displaced femoral neck fracture in physiologically active patients closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting is a suitable option to secure union and prevent development of AVN.

  8. Fractal analysis of bone architecture at distal radius

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Mimura, Hiroaki; Murase, Kenya; Sone, Teruki; Fukunaga, Masao

    2005-01-01

    Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass. (author)

  9. Orthopedic infections in equine long bone fractures and arthrodeses treated by internal fixation: 192 cases (1990-2006).

    Science.gov (United States)

    Ahern, Benjamin J; Richardson, Dean W; Boston, Raymond C; Schaer, Thomas P

    2010-07-01

    To determine the rate of postoperative infection (POI) for internal fixation repaired equine long bone fractures and arthrodeses and identify associated risk factors. Case series. Horses (n=192) with fracture repair of the third metacarpal and metatarsal bones, radius, ulna, humerus, tibia, and femur, or arthrodesis with internal fixation. Medical records (1990-2006) were reviewed for signalment, anatomic location, fracture classification and method of repair, technique and surgical duration, bacterial species isolated, postoperative care, onset of POI, and outcome. Of 192 horses (171 [89%] closed, 21 [11%] open fractures), 157 (82%) were discharged from the hospital. Infection occurred in 53 (28% horses), of which 31 (59%) were discharged. Repairs without POI were 7.25 times more likely to be discharged from the hospital. Closed fractures were 4.23 times more likely to remain uninfected and 4.59 times more likely to be discharged from the hospital compared with open fractures. Closed reduction and internal fixation was associated with a 2.5-fold reduction in rate of POI and a 5.9 times greater chance for discharge from the hospital compared with open reduction and internal fixation. Females had a strong trend for increased POI when compared with colts and stallion but not geldings. Overall rate of POI was 28%. Fracture classification, method of repair, gender, and surgical duration were significant risk factors.

  10. Monteggia fracture dislocation equivalents - analysis of eighteen cases treated by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Singh Ajay Pal

    2012-02-01

    fracture dislocation equivalents are rare injuries and pre-surgery recognition by radiographs and 3-D CT helps make optimal plan. The poor results usually relate to intraarticular damage, coronoid fractures and comminution of the ulna and radial head fractures. Key words: Monteggia’s fracture; Radius fracture; Ulna

  11. A remediation performance model for enhanced metabolic reductive dechlorination of chloroethenes in fractured clay till

    DEFF Research Database (Denmark)

    Manoli, Gabriele; Chambon, Julie C.; Bjerg, Poul L.

    2012-01-01

    A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation...

  12. Applicability and Effectiveness of Closed Reduction of Nasal Fractures under Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Vilela, Fernando

    2014-03-01

    Full Text Available Introduction A significant portion of patients treated in emergency departments have nasal fracture. It is important that the otolaryngologist know how to treat such damage. Objectives To evaluate the effectiveness of nasal fracture reduction under local anesthesia and tolerance to the procedure. Methods Twenty-four patients treated in the emergency department with closed reduction under local anesthesia were prospectively followed. Epidemiologic information and data regarding pain and complications during the management were noted. The degree of satisfaction was researched by visual analog scale. Results The majority of patients were male (75%, and the most common cause of injury was motor vehicle accident. We found a significant association between time to reduction and referred pain during the procedure. In patients in whom the procedure was delayed (over 3 days, there was less pain, and those who bled during the procedure had a shorter average time to reduction than the group of patients who did not bleed. Most patients were very satisfied, with more than 95% of these willing to undergo the same process again, if necessary. Conclusions The closed approach in the clinic under local anesthesia was effective and safe in restoration of the nose.

  13. Multiscale model reduction for shale gas transport in fractured media

    KAUST Repository

    Akkutlu, I. Y.

    2016-05-18

    In this paper, we develop a multiscale model reduction technique that describes shale gas transport in fractured media. Due to the pore-scale heterogeneities and processes, we use upscaled models to describe the matrix. We follow our previous work (Akkutlu et al. Transp. Porous Media 107(1), 235–260, 2015), where we derived an upscaled model in the form of generalized nonlinear diffusion model to describe the effects of kerogen. To model the interaction between the matrix and the fractures, we use Generalized Multiscale Finite Element Method (Efendiev et al. J. Comput. Phys. 251, 116–135, 2013, 2015). In this approach, the matrix and the fracture interaction is modeled via local multiscale basis functions. In Efendiev et al. (2015), we developed the GMsFEM and applied for linear flows with horizontal or vertical fracture orientations aligned with a Cartesian fine grid. The approach in Efendiev et al. (2015) does not allow handling arbitrary fracture distributions. In this paper, we (1) consider arbitrary fracture distributions on an unstructured grid; (2) develop GMsFEM for nonlinear flows; and (3) develop online basis function strategies to adaptively improve the convergence. The number of multiscale basis functions in each coarse region represents the degrees of freedom needed to achieve a certain error threshold. Our approach is adaptive in a sense that the multiscale basis functions can be added in the regions of interest. Numerical results for two-dimensional problem are presented to demonstrate the efficiency of proposed approach. © 2016 Springer International Publishing Switzerland

  14. Paediatric post-traumatic cortical defects of the distal radius

    International Nuclear Information System (INIS)

    Roach, Richard T.; Summers, Bruce N.; Cassar-Pullicino, Victor

    2002-01-01

    Paediatric post-traumatic cortical defects, although rare, are predominately seen affecting the distal radius following a greenstick or torus fracture. We review the literature and present a further two cases supported by CT and MRI. Images from an acute greenstick fracture are also presented to help understand the pathogenesis. Defects are typically solitary on plain radiographs and are usually noticed late, proximal to the site of compression. They are non-expansile in an otherwise healthy child. CT and MRI may reveal smaller multiple subperiosteal defects. Typical defects require no further management other than reassurance and advice that they may occasionally cause discomfort but resolve with time. (orig.)

  15. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Keykhosro Mardanpour

    2013-07-01

    Full Text Available BACKGROUND: This study was performed to evaluate functional and radiological results of pelvic ring fractures treatment by open reduction and internal fixation. METHOD: Thirty eight patients with unstable pelvic fractures, treated from 2002 to 2008 were retrospectively reviewed. The mean patients’ age was 37 years (range 20 to 67. Twenty six patients were men (4patients with type B and 22 patients with type C fracture and 12 women (7 patients with type B and 5 patients with type C fracture. The commonest cause was a road traffic accident (N=37, about 97%. Internal fixation was done by plaque with ilioinguinal and kocher-langenbeek approaches for anterior, posterior pelvic wall and acetabulum fracture respectively. Quality of reduction was graded according to Majeed score system. RESULTS: There were 11 type-C and 27 type-B pelvic fractures according to Tile’s classification. Thirty six patients sustained additional injuries. the commonest additional injury was lower extremity fracture. The mean follow-up was 45.6 months (range 16 to 84 months.The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients with type B pelvic fractures and functional outcome was excellent in 46%, good in 27%, fair in 27% and poor in 0% of the patients with type C pelvic fractures. There were four postoperative infections. No sexual functional problem was reported. Neurologic problem like Lateral cutaneous nerve of thigh injury recovered completely in 2 patients and partially in 2 patients. There was no significant relation between functional outcome and the site of fracture (P greater than 0.005. CONCLUSION: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization. It must be carried out as soon as the general condition of the patient permits, and even up to two weeks

  16. Evaluation of sarcopenia in patients with distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Koh, Young Do; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Sarcopenia is more prevalent in patients with distal radius fracture (DRF) than in age- and sex-matched controls. Lower appendicular mass index in men and weaker grip strength in both men and women increase the likelihood of DRF. Sarcopenia is a core component of physical frailty that predisposes older people to falls and negatively impacts the activities of daily living. The objectives of this study were to compare the prevalence of sarcopenia in patients with DRF with that in age- and sex-matched controls without DRF; and evaluate the association between sarcopenia and the occurrence of DRF. We prospectively recruited 132 patients over 50 years of age who sustained DRF due to fall and 132 age- and sex-matched controls without DRF. A definition of sarcopenia was based on the consensus of the Asian Working Group for Sarcopenia. Sarcopenic components including appendicular lean body mass, grip strength, and gait speed were compared between the two groups. Other factors assessed for the occurrence of DRF were age, gender, body mass index (BMI), lumbar, and hip bone mineral density (BMD) values. A conditional logistic regression analysis was conducted to evaluate the associations between sarcopenia and the occurrence of DRF. A total of 39 (30%) of 132 DRF patients were sarcopenic, whereas 23 (17%) of the 132 controls were within the sarcopenic criteria (p = 0.048). The patient group had significantly lower lean body mass and weaker grip strength than those of the control group. However, there was no significant difference in gait speed between the two groups. According to regression analysis, lower appendicular mass index in men was associated with an increased incidence of DRF (odds ratio [OR] = 0.84, 95% confidence interval [CI] = 0.72, 0.95) while weaker grip strength and lower total hip BMD values were associated with the occurrence of DRF in both men (OR = 0.77, 95% CI = 0.63, 0.92; and OR = 0.79, 95% CI = 0.64, 0.94, respectively) and women (OR

  17. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    Science.gov (United States)

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  18. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    Science.gov (United States)

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  19. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Born, Christopher T. [Temple University Hospital/Temple Children' s Hospital, Temple Sports Medicine, Marlton, NJ (United States); Grudziak, Jan S. [Children' s Hospital of Pittsburgh, Department of Orthopedic Surgery, Pittsburgh, PA (United States); Towbin, Richard B.

    2004-12-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  20. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    International Nuclear Information System (INIS)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D.; Born, Christopher T.; Grudziak, Jan S.; Towbin, Richard B.

    2004-01-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  1. Explosion Amplitude Reduction due to Fractures in Water-Saturated and Dry Granite

    Science.gov (United States)

    Stroujkova, A. F.; Leidig, M.; Bonner, J. L.

    2013-12-01

    Empirical observations made at the Semipalatinsk Test Site suggest that nuclear tests in the fracture zones left by previous explosions ('repeat shots') show reduced seismic amplitudes compared to the nuclear tests in virgin rocks. Likely mechanisms for the amplitude reduction in the repeat shots include increased porosity and reduced strength and elastic moduli, leading to pore closing and frictional sliding. Presence of pore water significantly decreases rock compressibility and strength, thus affecting seismic amplitudes. A series of explosion experiments were conducted in order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fracture zones of previously detonated explosions. Explosions in water-saturated granite were conducted in central New Hampshire in 2011 and 2012. Additional explosions in dry granite were detonated in Barre, VT in 2013. The amplitude reduction is different between dry and water-saturated crystalline rocks. Significant reduction in seismic amplitudes (by a factor of 2-3) in water-saturated rocks was achieved only when the repeat shot was detonated in the extensive damage zone created by a significantly larger (by a factor of 5) explosion. In case where the first and the second explosions were similar in yield, the amplitude reduction was relatively modest (5-20%). In dry rocks the amplitude reduction reached a factor of 2 even in less extensive damage zones. In addition there are differences in frequency dependence of the spectral amplitude ratios between explosions in dry and water-saturated rocks. Thus the amplitude reduction is sensitive to the extent of the damage zone as well as the pore water content.

  2. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    Science.gov (United States)

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Open reduction and internal fixation of intra-articular fractures of the mandibular condyle: our first experiences.

    Science.gov (United States)

    Vesnaver, Ales

    2008-10-01

    Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.

  4. Oral-motor and electromyographic characterization of patients submitted to open a nd closed reductions of mandibular condyle fracture.

    Science.gov (United States)

    Silva, Amanda Pagliotto da; Sassi, Fernanda Chiarion; Andrade, Claudia Regina Furquim de

    To characterize the oral-motor system of adults with mandibular condyle facture comparing the performance of individuals submitted to open reduction with internal fixation (ORIF) and closed reduction with mandibulomaxillary fixation (CRMMF). Study participants were 26 adults divided into three groups: G1 - eight individuals submitted to ORIF for correction of condyle fracture; G2 - nine individuals submitted to CRMMF for correction of condyle fracture; CG - nine healthy volunteers with no alterations of the orofacial myofunctional system. All participants underwent the same clinical protocol: assessment of the orofacial myofunctional system; evaluation of the mandibular range of motion; and surface electromyography (sEMG) of the masticatory muscles. Results indicated that patients with condyle fractures from both groups presented significant differences compared with those from the control group in terms of mobility of the oral-motor organs, mastication, and deglutition. Regarding the measures obtained for mandibular movements, participants with facial fractures from both groups showed significant differences compared with those from the control group, indicating greater restrictions in mandibular motion. As for the analysis of sEMG results, G1 patients presented more symmetrical masseter activation during the task of maximal voluntary teeth clenching. Patients with mandibular condyle fractures present significant deficits in posture, mobility, and function of the oral-motor system. The type of medical treatment does not influence the results of muscle function during the first six months after fracture reduction. Individuals submitted to ORIF of the condyle fracture present more symmetrical activation of the masseter muscle.

  5. Reabilitação das fraturas do rádio distal Rehabilitation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Patrícia Silva Hampe Barbosa

    2009-01-01

    Full Text Available O objetivo deste estudo foi avaliar a evidência do efeito e eleição da conduta terapêutica nas fraturas do rádio distal. A revisão sistemática utilizou as bases de dados PubMed, Lilacs, Pedro, Cochrane, Scielo, OTseeker, sem restrições de período de publicação, com as seguintes palavras chaves: fraturas do rádio, reabilitação, terapia ocupacional, fisioterapia, incluindo línguas inglesa, espanhola, francesa e portuguesa. Os estudos encontrados foram avaliados independentemente pelos dois autores utilizando critérios da escala PEDro. Estudos não experimentais foram incluídos em busca de esclarecimentos sobre a reabilitação. Foram encontrados 22 estudos, sendo 14 ensaios clínicos controlados randomizados (ECRs. Dentre eles, quatro compararam mobilização precoce com tratamento convencional apresentando evidência moderada a favor da primeira; sete confrontaram tratamento baseado em exercícios domiciliares com tratamento em consultório apontando evidência conflitiva (um deles também comprovou eficácia de mobilização acessória passiva; e três analisaram eficácia de procedimentos terapêuticos: campo eletromagnético pulsado, drenagem linfática, ultra-som, indicando evidências limitadas. Os nove estudos não experimentais encontrados não apresentaram informações suficientes sobre os questionamentos desta pesquisa. Observou-se uma tendência dos autores em utilizar os princípios gerais da reabilitação ao elaborar condutas terapêuticas, mas os procedimentos utilizados não estão bem atestados pela literatura.The aim of this study was to assess the evidence regarding the adoption and effectiveness of therapeutic procedures employed for rehabilitation of distal radius fractures. This systematic review used the following databases: PubMed, Lilacs, PEDro, Cochrane, Scielo and OTseeker, without time restrictions. The following keywords were searched for: distal radius fracture, rehabilitation, occupational therapy

  6. Percutaneous clamping of spiral and oblique fractures of the tibial shaft: a safe and effective reduction aid during intramedullary nailing.

    Science.gov (United States)

    Collinge, Cory A; Beltran, Michael J; Dollahite, Henry A; Huber, Florian G

    2015-06-01

    The reduction of tibial shaft fractures during intramedullary nailing is important if limb alignment is to be restored and successful clinical outcomes are expected. We have used a percutaneously applied (or open) clamp or clamps to achieve and maintain reduction during nailing of all amendable tibial shaft fractures. In this article, we describe the technique and preliminary results comparing closed, simple spiral and oblique tibial shaft fractures (OTA 42-A1 and A2) managed with percutaneous clamp-assisted nailing (CAN) versus nailing using manual reduction (MRN) held by the surgical team. In the MRN group, there were an increased fracture gap (P = 0.04) and trends toward malalignment (P = 0.07) and healing time (P = 0.06) compared with the CAN group. There were also trends in clinical; no wound complications occurred in either group. We have found that percutaneous CAN of closed, simple spiral and oblique tibial shaft fractures seems safe and allows for early predictable union with reproducible alignment compared with nailing using MRN.

  7. Reduction of lateral forces between the railway vehicle and the track in small-radius curves by means of active elements

    Directory of Open Access Journals (Sweden)

    Michálek T.

    2011-12-01

    Full Text Available This paper deals with a possibility of reduction of guiding forces magnitude in small-radius curves by means of active elements. These guiding forces characterize the lateral force interaction between the rail vehicle and the track and influence the wear of wheels and rails in curves. Their magnitudes are assessed in the framework of vehicle authorization process. However, in case of new railway vehicles with axleload of approximately 20t and more it is problematic to meet the condition of maximum value of the quasistatic guiding force which acts on the outer wheel of the 1st wheelset in small-radius curves. One of the possible ways how to reduce these forces is using the system of active yaw dampers. By means of computer simulations of guiding behaviour of a new electric locomotive, comparison of reached values of the quasistatic guiding forces in case of locomotive equipped with active yaw dampers and without them was performed. Influences of magnitude of force generated by the active yaw dampers, friction coefficient in wheel/rail contact and curve radius were analysed in this work, as well.

  8. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    Science.gov (United States)

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  9. Evaluation of scale effects on hydraulic characteristics of fractured rock using fracture network model

    International Nuclear Information System (INIS)

    Ijiri, Yuji; Sawada, Atsushi; Uchida, Masahiro; Ishiguro, Katsuhiko; Umeki, Hiroyuki; Sakamoto, Kazuhiko; Ohnishi, Yuzo

    2001-01-01

    It is important to take into account scale effects on fracture geometry if the modeling scale is much larger than the in-situ observation scale. The scale effect on fracture trace length, which is the most scale dependent parameter, is investigated using fracture maps obtained at various scales in tunnel and dam sites. We found that the distribution of fracture trace length follows negative power law distribution in regardless of locations and rock types. The hydraulic characteristics of fractured rock is also investigated by numerical analysis of discrete fracture network (DFN) model where power law distribution of fracture radius is adopted. We found that as the exponent of power law distribution become larger, the hydraulic conductivity of DFN model increases and the travel time in DFN model decreases. (author)

  10. [Manipulative reduction and small splint fixation combined with micromovement exercise for treatment of humeral shaft fractures].

    Science.gov (United States)

    Tang, Hao-chen; Xiang, Ming; Chen, Hang; Hu, Xiao-chuan; Yang, Guo-yong

    2016-01-01

    To investigate the therapeutic efficacy of bone-setting manipulative reduction and small splint fixation combined with micro-movement theory exercise for treatment of humeral shaft fractures. From March 2011 to February 2014, 64 cases of humeral shaft fractures were treated by bone-setting manipulative reduction and small splint fixation including 28 males and 36 females with an average age of 38.1 years old ranging from 22 to 67 years old. According to the classification of AO/OTA, there were 10 cases of type A1, 12 cases of type A2,11 cases of type A3,10 cases of type B1,12 cases of type B2, 7 cases of type B3, 2 cases of type C1, 1 case of type C2, 1 case of type C3. After close reduction early functional exercise performed according to micro-movement theory. All patients had no other parts of the fractures, neurovascular injury, and serious medical problems. Patients were followed up for fracture healing, shoulder and elbow joint function recovery, and curative effect. All patients were followed up from 10 to 12 months with an average of 10.3 months. Of them, 2 cases had a small amount of callus growth at 3 months after close reduction, so instead of operation; 2 cases appeared radial nerve symptoms after close reduction ,so instead of operation. Other patients were osseous healing, the time was 8 to 12 weeks with an average of 10.2 weeks. After osseous healing, according to Constant-Murley score system ,the average score was (93.5 ± 3.2) points, the result was excellent in 29 cases, good in 29 cases, fair in 6 cases, excellent and good rate was 90.3%; according to the Mayo score system, the average score was (93.7 ± 4.2) points, the result was excellent in 35 cases, good in 23 cases, fair in 6 cases, excellent and good rate was 91.9%. Bone-setting manipulative reduction and small splint fixation combined with micromovement theory exercise for treatment of humeral shaft fractures has advantage of positive effect, easy and inexpensive method, the treatment has

  11. Isolated fracture of pisiform: case report of a rare injury of wrist

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    ABSTRACT: Isolated fracture of the pisiform is an extremely rare injury. Generally fractures of the pisiform are associated with fractures of other carpal bones or the distal radius. Fractures of the carpals and metacarpals account for roughly 6% of all fractures. The average incidence of pisiform fractures is 0.2% of all carpal ...

  12. Reduction of rib fractures with a bioresorbable plating system: preliminary observations.

    Science.gov (United States)

    Vu, Kim-Chi; Skourtis, Mia E; Gong, Xi; Zhou, Minhao; Ozaki, Wayne; Winn, Shelley R

    2008-05-01

    Operative fixation of rib fractures can reduce morbidity and mortality. Currently, resorbable fixation devices are used in a variety of surgical procedures. A standard osteotomy was prepared in 30 New Zealand white rabbits at the 12th rib. Eighteen had surgical repair with bioresorbable plates and 12 underwent nonoperative management. Half the animals in each group were killed at 3-week postfracture and the remaining animals were killed at 6-week postfracture. Ribs were radiographed and processed histologically to assess fracture healing. Rib reduction was defined as the alignment of the rib ends in a structural condition similar to the prefractured state and quantitative radiomorphometry measured the radiopaque callus surrounding the rib injury sites. Statistical analysis was performed using Fisher's exact test and an unpaired Student's t test and significance was established at p rib fractures remained reduced in the operative group, whereas zero of six and three of six of the rib fractures remained reduced, respectively, in the nonoperative group. A statistically significant increase in radiopaque callus surrounding the rib injury sites was observed at 3 and 6 weeks in the fixed groups. Fixation of rib fractures with a bioresorbable miniplate system was superior to nonoperative treatment at the 3-week interval, with a statistically significant increase in radiopaque callus formation at both 3 and 6 weeks. Additional studies will evaluate the biomechanical outcomes and degradation tissue response after extended in vivo intervals.

  13. Open reduction versus endoscopically controlled reconstruction of orbital floor fractures: a retrospective analysis.

    NARCIS (Netherlands)

    Hundepool, A.C.; Willemsen, M.A.A.P.; Koudstaal, M.J.; Wal, K.G.H. van der

    2012-01-01

    The aim of this study was to compare the postoperative results of open reduction versus endoscopically controlled reconstructions of orbital floor fractures. The medical records of 83 patients, treated between January 2000 and December 2008, were reviewed for enophthalmos, diplopia and

  14. Bimalleolar ankle fracture with proximal fibular fracture

    NARCIS (Netherlands)

    Colenbrander, R. J.; Struijs, P. A. A.; Ultee, J. M.

    2005-01-01

    A 56-year-old female patient suffered a bimalleolar ankle fracture with an additional proximal fibular fracture. This is an unusual fracture type, seldom reported in literature. It was operatively treated by open reduction and internal fixation of the lateral malleolar fracture. The proximal fibular

  15. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    Science.gov (United States)

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without

  16. Computer simulation of ductile fracture

    International Nuclear Information System (INIS)

    Wilkins, M.L.; Streit, R.D.

    1979-01-01

    Finite difference computer simulation programs are capable of very accurate solutions to problems in plasticity with large deformations and rotation. This opens the possibility of developing models of ductile fracture by correlating experiments with equivalent computer simulations. Selected experiments were done to emphasize different aspects of the model. A difficult problem is the establishment of a fracture-size effect. This paper is a study of the strain field around notched tensile specimens of aluminum 6061-T651. A series of geometrically scaled specimens are tested to fracture. The scaled experiments are conducted for different notch radius-to-diameter ratios. The strains at fracture are determined from computer simulations. An estimate is made of the fracture-size effect

  17. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  18. Angular deformation of radius and ulna treated by dynamic percutaneus osteogenesis distraction. Case report

    International Nuclear Information System (INIS)

    Rezende, C.M.F.; Melo, E.G.; Lamas, M.C.S.; Silva, C.A.

    2000-01-01

    The clinical exam of a male mongrel dog, 4-month-old, and 5.7kg of live weight, showed that the dog supported with the elbows and it was observed accentuated bilateral rotacional deformity of the radius and ulna. Radiographs of the radius and ulna revealed proximal fracture of the radius. After clinical and radiographic evaluation it was indicated the corrective osteotomy and distraction osteogenesis of the left foremember. The surgical procedure consisted in osteotomy in the diaphysis of the radius and ulna, and the utilization of external fixators composed by four Kirschner’s pins and two metallic thread bars, configuring a fixator type II, bilateral uniplanar dynamic. Before the fixation of the pins with acrylic, the fractured bony fragments were separated in approximately 0.5cm. Starting 10 days post surgery, the radial osteotomy site was distracted at a rate of 1.0mm every day for 30 days. The consolidation of the osteotomy site was observed radiographically 67 days after the intervention, when the fixator was removed. Similar procedure was accomplished in the right foremember at the age of 16 months. At this moment, it was necessary to remove a coins bony of approximately 1.0cm for correction of the limb angulation. At present, the dog shows normal function and support of the left foremember and light valgus deformity of the right foremember due to the broken implants [pt

  19. Closed reduction of displaced or dislocated mandibular condyle fractures in children using threaded Kirschner wire and external rubber traction.

    Science.gov (United States)

    Kim, J H; Nam, D H

    2015-10-01

    Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Daily number of fractures is associated with road temperature in an urban area

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Thomsen, Morten

    2014-01-01

    winters. MATERIAL AND METHODS: Retrospective data collection was conducted on all patients treated at Bispebjerg Hospital, Denmark, for a humeral, ankle, distal radius or hip fracture during the periods October to April 2009/2010 and 2010/2011. Patients were grouped according to age into the following......,938 fractures) were treated during the study periods. The daily number of distal radius, humeral and ankle fractures increased significantly with decreasing road surface temperature and the presence of IA. For hip fractures no significant association was found. Decreasing temperature was associated......INTRODUCTION: Different factors related to winter are known to influence the fracture incidence, but little is known about the effect of road surface temperature. This study examines the association between road surface temperature and the daily number of fractures in an urban area during two...

  1. Two new methods for the determination of hydraulic fracture ...

    African Journals Online (AJOL)

    2008-09-15

    Sep 15, 2008 ... Flow is radial and divergent. • There is only a single fracture within the test segment. • The fracture and rock mass are rigid and the matrix is imper- meable. • The fracture aperture varies along the radius and is radically symmetrical about the borehole. • Advection, dispersion and diffusion are negligible due ...

  2. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    Science.gov (United States)

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  3. Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Marianne

    2015-01-01

    BACKGROUND: Operative treatment of displaced calcaneal fractures should restore joint congruence, but conventional fluoroscopy is unable to fully visualize the subtalar joint. We questioned whether intraoperative 3-dimensional (3D) imaging would aid in the reduction of calcaneal fractures......, resulting in improved articular congruence and implant positioning. METHOD: Sixty-two displaced calcaneal fractures were operated on using standard fluoroscopic views. When the surgeon had achieved a satisfactory reduction, an intraoperative 3D scan was conducted, malreductions or implant imperfections were...

  4. Over-extending reduction combined with unilateral approach percutaneous vertebroplasty for the treatment of vertebral compression fractures due to osteoporosis

    International Nuclear Information System (INIS)

    Wei Xinjian; Ji Xianghui; Cao Fei; Zhang Fuhua

    2012-01-01

    Objective: To assess the clinical effect of over-extending reduction combined with percutaneous vertebroplasty (PVP) in treating vertebral compression fractures caused by osteoporosis. Methods: A total of 16 patients with vertebral compression fractures due to osteoporosis were treated with over-extending reduction by using traction on the operation table, and then PVP through trans-single-pedicular approach was performed on the fractured vertebra. The visual analogue scale (VAS) was used to evaluate the clinical effectiveness. The preoperative and postoperative heights of the fractured vertebral body were determined, and the vertebral height recovery ratio was calculated. Results: Technical success was achieved in 20 vertebrae of 16 cases. Bone cement leakage was observed in front of the vertebral body (n=5), in the side of vertebral body (n=20) and within the intervertebral (n=2). After the treatment VAS score decreased from preoperative 8.5±1.2 to postoperative 2.5±1.4. The vertebral height recovery ratio was (40.1±23.5)%. After the surgery, the VAS score and the vertebral height were significantly improved (P<0.05). Conclusion: The over-extending reduction combined with PVP through trans-single-pedicular approach is an effective treatment for vertebral compression fractures caused by osteoporosis. (authors)

  5. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  6. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    Directory of Open Access Journals (Sweden)

    Tabet A. Al-Sadek

    2016-11-01

    Full Text Available BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with

  7. Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus

    NARCIS (Netherlands)

    Wijgman, A. J.; Roolker, W.; Patt, T. W.; Raaymakers, E. L. F. B.; Marti, R. K.

    2002-01-01

    BACKGROUND: Controversy persists concerning the preferred treatment of displaced fractures of the proximal part of the humerus. The present study was undertaken to evaluate the results of open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus and

  8. Transpedicular hydroxyapatite grafting with indirect reduction for thoracolumbar burst fractures with neurological deficit: A prospective study

    Directory of Open Access Journals (Sweden)

    Toyone Tomoaki

    2007-01-01

    Full Text Available Background: The major problem after posterior correction and instrumentation in the treatment of thoracolumbar burst fractures is failure to support the anterior spinal column leading to loss of correction of kyphosis and hardware breakage. We conducted a prospective consecutive series to evaluate the outcome of the management of acute thoracolumbar burst fractures by transpedicular hydroxyapatite (HA grafting following indirect reduction and pedicle screw fixation. Materials and Methods: Eighteen consecutive patients who had thoracolumbar burst fractures and associated incomplete neurological deficit, operatively treated within four days of admission. Following indirect reduction and pedicle screw fixation, transpedicular intracorporeal HA grafting to the fractured vertebrae was performed. Mean operative time was 125 min and mean blood loss was 150 ml. Their implants were removed within one year and were prospectively followed for at least two years. Results: The neurological function of all 18 patients improved by at least one ASIA grade, with nine (50% patients demonstrating complete neurological recovery. Sagittal alignment was improved from a mean preoperative kyphosis of 17°to -2°(lordosis by operation, but was found to have slightly deteriorated to 1° at final follow-up observation. The CT images demonstrated a mean spinal canal narrowing pre-operatively immediate post-operative and at final followup of 60%, 22% and 11%, respectively . There were no instances of hardware failure. No patient reported severe pain or needed daily dosages of analgesics at the final follow-up. The two-year postoperative MRI demonstrated an increase of one grade in disc degeneration (n = 17 at the disc above and in 11 patients below the fractured vertebra. At the final follow-up, flexion-extension radiographs revealed that a median range of motion was 4, 6 and 34 degrees at the cranial segment of the fractured vertebra, caudal segment and L1-S1, respectively

  9. [The randomized controlled trial of the treatment for clavicular fracture by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation].

    Science.gov (United States)

    Bi, Hong-zheng; Yang, Mao-qing; Tan, Yuan-chao; Fu, Song

    2008-07-01

    To study the curative effect and safety of rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation in treating clavicular fracture. All 201 cases of clavicular fractures were randomly divided into treatment group (101 cases) and control group (100 cases). The treatment group was treated by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation. The control group was treated by open reduction and internal fixation with Kirschner pin. All cases were followed up for 4 to 21 months (mean 10.6 months). SPSS was used to analyze clinic healing time of fracture and shoulder-joint function in both two groups. After operation, 101 cases of treatment group achieved union of fracture and the clinical healing time was 28 to 49 days (mean 34.5+/-2.7 days). In control group,there were 4 cases with nonunion of fracture,the other 96 cases were union,the clinical healing time was 36 to 92 days (mean 55.3+/-4.8 days). The excellent and good rate of shoulder-joint function was 100% in treatment group and 83% in control group. By t-test and chi2-test, there was significant difference between the two groups in curative effect (Pmanual reduction with forceps holder and retrograde pinning transfixation can be used in various kinds of clavicular shaft fracture, with many virtues such as easy operation, reliable fixation, short union time of fracture, good functional recovery of shoulder-joint and no incision scar affecting appearance.

  10. A partitioned model order reduction approach to rationalise computational expenses in nonlinear fracture mechanics

    Science.gov (United States)

    Kerfriden, P.; Goury, O.; Rabczuk, T.; Bordas, S.P.A.

    2013-01-01

    We propose in this paper a reduced order modelling technique based on domain partitioning for parametric problems of fracture. We show that coupling domain decomposition and projection-based model order reduction permits to focus the numerical effort where it is most needed: around the zones where damage propagates. No a priori knowledge of the damage pattern is required, the extraction of the corresponding spatial regions being based solely on algebra. The efficiency of the proposed approach is demonstrated numerically with an example relevant to engineering fracture. PMID:23750055

  11. Fracture Risk Assessment in Chronic Kidney Disease, Prospective Testing Under Real World Environments (FRACTURE: a prospective study

    Directory of Open Access Journals (Sweden)

    West Sarah L

    2010-08-01

    Full Text Available Abstract Background Chronic kidney disease (CKD is associated with an increased risk of fracture. Decreased bone mass and disruption of microarchitecture occur early in the course of CKD and worsens with the progressive decline in renal function so that at the time of initiation of dialysis at least 50% of patients have had a fracture. Despite the excess fracture risk, and the associated increases in morbidity and mortality, little is known about the factors that are associated with an increase in fracture risk. Our study aims to identify prognostic factors for bone loss and fractures in patients with stages 3 to 5 CKD. Methods This prospective study aims to enroll two hundred and sixty men and women with stages 3 to 5 CKD. Subjects will be followed for 24 months and we will examine the ability of: 1 bone mineral density by dual x-ray absorptiometry at the spine, hip, and radius; 2 volumetric bone density by high resolution peripheral quantitated computed tomography at the radius and tibia; 3 serum markers of bone turnover; 4 bone formation rate by bone biopsy; and 5 muscle strength and balance to predict spine and non-spine fractures, identified by self-report and/or vertebral morphometry. All measurements will be obtained at baseline, at 12 and at 24 months with the exception of bone biopsy, which will be measured once at 12 months. Subjects will be contacted every 4 months to determine if there have been incident fractures or falls. Discussion This study is one of the first that aims to identify risk factors for fracture in early stage CKD patients. Ultimately, by identifying risk factors for fracture and targeting treatments in this group-before the initiation of renal replacement therapy - we will reduce the burden of disease due to fractures among patients with CKD.

  12. Use of intra-medullary stacked nailing in the reduction of proximal plastic deformity in a pediatric Monteggia fracture: a case report

    Directory of Open Access Journals (Sweden)

    Huntley James S

    2011-04-01

    Full Text Available Abstract Introduction In a Monteggia fracture dislocation, it is important to reduce the ulnar fracture completely. Extensive plastic deformation of the proximal ulna may make reduction by closed manipulation impossible. Case presentation We report the case of a four-year-old Caucasian boy in whom the plastic deformation of the proximal ulna was reduced, and this reduction was maintained, using intra-medullary stacked nailing. Conclusion The technique of stacked nailing is a useful addition to the armamentarium in the management of the potentially awkward Monteggia fracture.

  13. An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture.

    Science.gov (United States)

    Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal

    2015-01-01

    Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable plates. Different methods have various pros and cons. The choice of anesthesia is also very crucial sometimes. This case report describes a new method of closed reduction with 18 gauge needle simulated as an arch bar performed under local anaesthesia.

  14. An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture

    OpenAIRE

    Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal

    2015-01-01

    Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable ...

  15. Development of stress-modified fracture strain criterion for ductile fracture of API X65 steel

    International Nuclear Information System (INIS)

    Oh, Chang Kyun; Kim, Yun Jae; Park, Jin Moo; Kim, Woo Sik; Baek, Jong Hyun

    2005-01-01

    This paper presents a stress-modified fracture strain for API X65 steel used for gas pipeline, as a function of stress triaxiality. To determine the stress-modified fracture strain, tension test of bars with four different notch radii, made of API X65 steel, is firstly performed, from which true fracture strains are determined as a function of notch radius. Then detailed elastic-plastic, large strain Finite Element (FE) analyses are performed to estimate variations of stress triaxiality in the notched bars with load. Combining experimental with FE results provides the true fracture strain as a function of stress triaxiality, which is regarded as a criterion of ductile fracture. Application of the developed stress-modified fracture strain to failure prediction of gas pipes made of API X65 steel with various types of defects is discussed

  16. Indentation deformation and fracture of thin polystyrene films

    International Nuclear Information System (INIS)

    Li Min; Palacio, Manuel L.; Barry Carter, C.; Gerberich, William W.

    2002-01-01

    Nanoindentation-induced deformation and fracture of thin polystyrene (PS) films on glass substrates were characterized using visible-light microscopy and atomic force microscopy (AFM). Two film thicknesses, 2 and 3.5 μm were studied. It was difficult to induce delamination in the 2-μm film while the 3.5-μm film delaminated easily under indentation loads of 150 mN and higher. AFM cross-section analysis of the deformation and fracture geometry revealed that the ratio of the delamination radius to contact radius was between 3 and 4. Analysis of the fracture surface on the glass side indicates that substrate cracking acts as a trigger for initiation and propagation of interfacial cracks. Crack-arrest marks and process-zone marks were also observed by AFM imaging. The interfacial fracture toughness, or practical work of adhesion, was evaluated following two methods based on the indentation-induced delamination and a process-zone analysis. The fracture toughness was found to be approximately 0.6 J/m 2 for the 3.5-μm PS film on glass. AFM examination of the glass surface after indentation also showed fine flow lines around the indentation impression, indicating plastic deformation of glass

  17. Indentation deformation and fracture of thin polystyrene films

    Energy Technology Data Exchange (ETDEWEB)

    Li Min; Palacio, Manuel L.; Barry Carter, C.; Gerberich, William W

    2002-09-02

    Nanoindentation-induced deformation and fracture of thin polystyrene (PS) films on glass substrates were characterized using visible-light microscopy and atomic force microscopy (AFM). Two film thicknesses, 2 and 3.5 {mu}m were studied. It was difficult to induce delamination in the 2-{mu}m film while the 3.5-{mu}m film delaminated easily under indentation loads of 150 mN and higher. AFM cross-section analysis of the deformation and fracture geometry revealed that the ratio of the delamination radius to contact radius was between 3 and 4. Analysis of the fracture surface on the glass side indicates that substrate cracking acts as a trigger for initiation and propagation of interfacial cracks. Crack-arrest marks and process-zone marks were also observed by AFM imaging. The interfacial fracture toughness, or practical work of adhesion, was evaluated following two methods based on the indentation-induced delamination and a process-zone analysis. The fracture toughness was found to be approximately 0.6 J/m{sup 2} for the 3.5-{mu}m PS film on glass. AFM examination of the glass surface after indentation also showed fine flow lines around the indentation impression, indicating plastic deformation of glass.

  18. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    Science.gov (United States)

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  19. Reduction of femoral fractures in long-term care facilities: the Bavarian fracture prevention study.

    Directory of Open Access Journals (Sweden)

    Clemens Becker

    Full Text Available BACKGROUND: Hip fractures are a major public health burden. In industrialized countries about 20% of all femoral fractures occur in care dependent persons living in nursing care and assisted living facilities. Preventive strategies for these groups are needed as the access to medical services differs from independent home dwelling older persons at risk of osteoporotic fractures. It was the objective of the study to evaluate the effect of a fall and fracture prevention program on the incidence of femoral fracture in nursing homes in Bavaria, Germany. METHODS: In a translational intervention study a fall prevention program was introduced in 256 nursing homes with 13,653 residents. The control group consisted of 893 nursing homes with 31,668 residents. The intervention consisted of staff education on fall and fracture prevention strategies, progressive strength and balance training, and on institutional advice on environmental adaptations. Incident femoral fractures served as outcome measure. RESULTS: In the years before the intervention risk of a femoral fracture did not differ between the intervention group (IG and control group (CG. During the one-year intervention period femoral fracture rates were 33.6 (IG and 41.0/1000 person years (CG, respectively. The adjusted relative risk of a femoral fracture was 0.82 (95% CI 0.72-0.93 in residents exposed to the fall and fracture prevention program compared to residents from CG. CONCLUSIONS: The state-wide dissemination of a multi-factorial fall and fracture prevention program was able to reduce femoral fractures in residents of nursing homes.

  20. A Novel Minimally Invasive Reduction Technique by Balloon and Distractor for Intra-Articular Calcaneal Fractures: A Report of 2 Cases

    Directory of Open Access Journals (Sweden)

    M. Prod’homme

    2018-01-01

    Full Text Available Treatment of displaced intra-articular fractures of the calcaneus remains a challenge for the orthopaedic surgeon. Conservative therapy is known to produce functional impairment. Surgical approach is plagued by soft-tissue complications and insufficient fracture reduction. We describe a minimally invasive technique that will hopefully improve these issues. We want to present our first experience through two cases. The first was a 46-year-old man who presented with a Sanders type IIBC calcaneal fracture, and the second was a 86-year-old woman with a type IIIBC calcaneal fracture. We introduced 2 Schanz screws in the talus and the calcaneus. After distraction, we introduced an inflatable balloon inside the calcaneus. By inflating the balloon, the articular surface was reduced by lifting it up. Then bone cement was injected in order to maintain the reduction. Additional screw fixation was used in the young patient. Postoperative imaging showed good congruence of the subtalar joint without leakage of cement, for the two cases. After 2 months, the patients had no pain and were without soft-tissue complications. We advocate this technique to perform a minimally invasive reduction and fixation of intra-articular calcaneal fractures because it preserves soft-tissues and provides good clinical results with early weight-bearing.

  1. Occupational therapy and Colles' fractures

    OpenAIRE

    Christensen, O.M.; Kunov, A.; Hansen, F.F.; Christiansen, T.C.; Krasheninnikoff, M.

    2000-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups ...

  2. Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Dennis; Toendevold, Erik

    2015-01-01

    was evaluated on reconstructed coronal and sagittal images of the acetabulum. Results - The fracture severity and patient characteristics were similar in the 2 groups. In the 3D group, 46 of 72 patients (0.6) had a perfect result after open reduction and internal fixation, and in the control group, 17 of 42 (0...

  3. Preliminary experience with biodegradable implants for fracture fixation

    Directory of Open Access Journals (Sweden)

    Dhillon Mandeep

    2008-01-01

    Full Text Available Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum, were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.

  4. Fracture Mechanics Assessment for Different Notch Sizes Using Finite Element Analysis Based on Ductile Failure Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Keun Hyung; Jeon, Jun Young; Han, Jae Jun; Nam, Hyun Suk; Lee, Dae Young; Kim, Yun Jae [Korea Univ., Seoul (Korea, Republic of)

    2016-08-15

    In this study, notch defects are evaluated using fracture mechanics. To understand the effects of notch defects, FE analysis is conducted to predict the limit load and J-integral for middle-cracked and single-edge cracked plates with various sizes of notch under tension and bending. As the radius of the notch increases, the energy release rate also increases, although the limit load remains constant. The values of fracture toughness(J{sub IC}) of SM490A are determined for various notch radii through FE simulation instead of conducting an experiment. As the radius of the notch increases, the energy release rate also increases, together with a more significant increase in fracture toughness. To conclude, as the notch radius increases, the resistance to crack propagation also increases.

  5. Mandibular ramus fractures: a rarity.

    Science.gov (United States)

    Kale, Tejraj Pundalik; Kotrashetti, S M; Louis, Archana; Lingaraj, J B; Sarvesh, B U

    2013-01-01

    To determine the incidence of mandibular ramus fractures in KLE's PK Hospital and to analyze the outcome of open reduction and internal fixation of these fractures. Using a retrospective study design, records of all trauma patients who reported to the Department of Oral and Maxillofacial Surgery, KLE's PK Hospital Belgaum, between the years January 2006 to October 2011 was obtained from the medical records office. The data variables that were analyzed were the name, age, sex, cause of injury, pretreatment occlusion, treatment given, period of MMF and post-treatment occlusion. Total number of mandibular fracture cases was 298. Ramus fractures were 10 in number which accounted for 3.3% of fractures. The age range of these 10 patients was seen to be between 20 to 80 years with the average age being 35.6 years. Of these 10 patients, 9 were male and 1 was female and 7 patients were treated by open reduction and internal fixation and the remaining 3 by closed reduction. The average period of MMF was 3 days for the patients who underwent open reduction and internal fixation. There was improvement in occlusion in all 10 patients post-treatment and there was no complication reported in any of the cases. Ramus fractures accounted for 3.3% of all mandibular fractures. Open reduction and internal fixation of ramus fractures ensures adequate functional and anatomic reduction. This study makes an attempt to throw a light on the increasing incidence of ramus fractures and a successful management of these fractures by open reduction and internal fixation. How to cite this article: Kale TP, Kotrashetti SM, Louis A, Lingaraj JB, Sarvesh BU. Mandibular Ramus Fractures: A Rarity. J Contemp Dent Pract 2013;14(1):39-42. Source of support: Nil Conflict of interest: None declared.

  6. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    Science.gov (United States)

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark

  7. Numerical Analysis of AHSS Fracture in a Stretch-bending Test

    Science.gov (United States)

    Luo, Meng; Chen, Xiaoming; Shi, Ming F.; Shih, Hua-Chu

    2010-06-01

    Advanced High Strength Steels (AHSS) are increasingly used in the automotive industry due to their superior strength and substantial weight reduction advantage. However, their limited ductility gives rise to numerous manufacturing issues. One of them is the so-called `shear fracture' often observed on tight radii during stamping processes. Since traditional approaches, such as the Forming Limit Diagram (FLD), are unable to predict this type of fracture, efforts have been made to develop failure criteria that can predict shear fractures. In this paper, a recently developed Modified Mohr-Coulomb (MMC) ductile fracture criterion[1] is adopted to analyze the failure behavior of a Dual Phase (DP) steel sheet during stretch bending operations. The plasticity and ductile fracture of the present sheet are fully characterized by the Hill'48 orthotropic model and the MMC fracture model respectively. Finite Element models with three different element types (3D, shell and plane strain) were built for a Stretch Forming Simulator (SFS) test and numerical simulations with four different R/t ratios (die radius normalized by sheet thickness) were performed. It has been shown that the 3D and shell element models can accurately predict the failure location/mode, the upper die load-displacement responses as well as the wall stress and wrap angle at the onset of fracture for all R/t ratios. Furthermore, a series of parametric studies were conducted on the 3D element model, and the effects of tension level (clamping distance) and tooling friction on the failure modes/locations were investigated.

  8. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  9. Uncommon Dorsal Radiocarpal Fracture Dislocation Complicated With Median Nerve Palsy: Case Report, Review of the Literature, and a New Classification System Guiding the Management

    Directory of Open Access Journals (Sweden)

    Hing-Cheong Wong

    2012-06-01

    Full Text Available We report the case of a 36-year-old lorry driver who sustained left dorsal radiocarpal fracture dislocation and left median nerve injury in a traffic accident in 2010. Emergency operation of closed reduction, cross-wrist-bridging external fixation, percutaneous transradial styloid Kirschner wire fixation, decompression of left median nerve, and repair of the partially torn palmar radiocarpal ligament were performed under general anaesthesia. Because of the persistent depressed dorsal articular rim fracture of left distal radius, another operation of open reduction, corticocancellous bone grafting, and dorsal buttress plating was performed 5 days after the initial operation. Six months after the operation, the patient enjoyed good range of wrist motion but weak twisting power, especially in supination. There was no radiological feature of radiocarpal subluxation.

  10. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  11. Update on open reduction and internal fixation of unstable pelvic fractures during pregnancy: case reports

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    Full Text Available ABSTRACT This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report: The study included four cases of pregnant women with unstable pelvic fractures; their outcomes were analyzed and discussed. Data were obtained from two University Hospitals. The mean age of women was 23 years; most (3/4 were primiparous, with a mean pregnancy age of 23 weeks. Two women had Malgaigne-type fractures and the other two had symphyseal disjunction associated with acetabular fractures. All fractures were treated surgically. One foetus was dead on admission to hospital. The other three developed well, along with their mothers. Good evolution was only possible with careful pre-, peri-, and postoperative care for the mother, as well as foetal assessment by a multidisciplinary team. In complex cases such as those presented in the present study, pre-, peri-, and postoperative care are mandatory, as well as the presence of a multidisciplinary team. The mother's life always takes priority in acute clinical pictures, as it offers the best chance of survival to both mother and child.

  12. Fracture toughness evaluation of small notched specimen in consideration of notch effect and loading rate

    International Nuclear Information System (INIS)

    Lee, Baik Woo; Kwon, Dong Il; Jang, Jae Il

    2000-01-01

    Notch effect and loading rate dependency on fracture toughness were considered when evaluating fracture toughness of small notched specimens using the instrumented impact test. Notch effect was analyzed into stress redistribution effect and stress relaxation with a viewpoint of stress triaxiality. Stress redistribution effect was corrected by introducing effective crack length, which was the sum of actual crack length and plastic zone size. Stress relaxation effect was also corrected using elastic stress concentration factor, which would decrease if plastic deformation occurred. As a result, corrected fracture toughness of the notched specimen was very consistent with the reference fracture toughness obtained using precracked specimen. In addition, limiting notch root radius, below which fracture toughness was independent of notch radius, was observed and discussed. Loading rate dependency on fracture toughness, which was obtained from the static three point bending test and the instrumented impact test, was also discussed with stress field in plastic zone ahead of a notch and fracture based on stress control mechanism. (author)

  13. Post-surgical rehabilitative approach to fragility fractures.

    Science.gov (United States)

    Gimigliano, F; Iolascon, G; Riccio, I; Frizzi, L; Gimigliano, R

    2013-10-01

    Osteoporosis is a skeletal disorder characterized by compromised bone strength predisposing to an increased risk of fracture. The most frequent sites of fragility fractures are the hip, the distal radius, the spine, the proximal humerus, and the ankle. In most cases, a surgical approach with subsequent rehabilitative treatment is required. The general aims of rehabilitation are to increase functioning and improve patients' activities, participation level, and quality of life.

  14. Use of a Hybrid Operating Room to Improve Reduction of Syndesmotic Injuries in Ankle Fractures: A Case Report.

    Science.gov (United States)

    Cancienne, Jourdan M; Crosen, Matelin P; Yarboro, Seth R

    2016-01-01

    Ankle fractures are one of the most common orthopedic injuries requiring operative treatment, and approximately 1 in 4 ankle fractures will have an associated distal tibiofibular syndesmosis disruption. Syndesmotic reduction is crucial to restoring ankle function and preventing the development of arthritis. The hybrid operating room provides 3-dimensional intraoperative imaging capabilities that can enable the surgeon to ensure the syndesmosis is appropriately reduced, particularly by comparing it with the contralateral ankle. By confirming the syndesmosis reduction intraoperatively, the risk of a return to the operating room for revision surgery is decreased. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Transoral open reduction and fixation of mandibular condylar base and neck fractures in children and young teenagers--a beneficial treatment option?

    Science.gov (United States)

    Schiel, Sebastian; Mayer, Peter; Probst, Florian; Otto, Sven; Cornelius, Carl-Peter

    2013-07-01

    To evaluate the possible benefits of open surgery, endoscopically assisted reduction and fixation using a transoral route was used in a selected series of pediatric patients with displaced condylar base and neck fractures. A cohort of 6 patients (1 male and 5 female; age range, 7 to 15 yr; mean, 13.4 yr) with displaced condylar base and neck fractures (n = 9) were included. Inclusion criteria were age younger than 16 years, fracture of the condylar base or neck, and displacement of the fracture by at least 45°. Fractures were classified using conventional radiography, cone-beam computed tomography, or computed tomography. Patients underwent transoral endoscopically assisted open reduction and fixation using miniplate osteosynthesis. Postoperatively, patients were followed clinically and radiographically for 18 months. Complete follow-up varied from 18 to 35 months (median, 24.5 months). All patients showed normal occlusion and pain-free unrestricted function of the temporomandibular joint at 3, 6, 12, and 18 months postoperatively. There were no signs of incomplete remodeling or deformation of the condyles. Transoral endoscopically assisted surgical treatment of severely displaced condylar base and neck fractures in children and young teenagers offers a reliable solution to preclude the sequelae of closed treatment, such as altered morphology and functional disturbances, eliminates visible scars, and lowers the risk of facial nerve damage compared with open reduction using an extraoral approach. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  16. Efficacy Evaluation for the Treatment of Subcapital Femoral Neck Fracture in Young Adults by Capsulotomy Reduction and Closed Reduction

    Directory of Open Access Journals (Sweden)

    Cong Liu

    2015-01-01

    Full Text Available Background: Subcapital femoral neck fracture in young adults has many complications, and the incidence is increasing year-by-year. The selection of the proper operation method to avoid them is an ambiguous matter. This study aimed to evaluate the treatment effect of subcapital femoral neck fracture by the capsulotomy and internal fixation with iliac bone grafting or closed reduction and internal fixation in young adults. Methods: From March 2003 to February 2010, 65 young patients with subcapital femoral neck fractures were treated, including 39 males and 26 females with average age of 34.5 years (range, 19-50 years; 29 cases of the left side and 36 cases of the right side. They were randomly divided into Group A with 34 cases treated by closed reduction and internal fixation and Group B with 31 cases treated by the capsulotomy and internal fixation with iliac bone grafting. The two groups had no significant differences in sex, age, body mass index and preoperative Harris Hip Score. The observation criteria involved the length of the incision, blood loss, operation time, nonunion rate, avascular necrosis of the femoral head (ANFH rate and Harris Hip Score. Results: Four of 65 patients were lost follow-up, and the follow-up rate was 93.8%, the average follow-up time was 38.7 months (range, 33-47 months. In Group A, the incision length was 5.1 ± 2.2 cm, blood loss was 84.0 ± 13.2 ml, and operation time was 52.9 ± 10.2 min. In Group B, the incision length was 15.4 ± 4.6 cm, blood loss was 396.0 ± 21.3 ml, and operation time was 116.5 ± 15.3 min. Nonunion occurred in 8 patients (25.2% in Group A and 1 patient (3.3% in Group B. ANFH occurred in 9 patients (29.1% in Group A and 2 patients (6.7% in Group B. Postoperative Harris Hip Score was 89.0 ± 5.6 in Group A and 95.0 ± 4.5 in Group B. The above index of two groups was considered statistically significant (P < 0.05. Conclusions: Capsulotomy and internal fixation with iliac bone grafting can

  17. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  18. Simulation of complex fracture networks influenced by natural fractures in shale gas reservoir

    Directory of Open Access Journals (Sweden)

    Zhao Jinzhou

    2014-10-01

    Full Text Available When hydraulic fractures intersect with natural fractures, the geometry and complexity of a fracture network are determined by the initiation and propagation pattern which is affected by a number of factors. Based on the fracture mechanics, the criterion for initiation and propagation of a fracture was introduced to analyze the tendency of a propagating angle and factors affecting propagating pressure. On this basis, a mathematic model with a complex fracture network was established to investigate how the fracture network form changes with different parameters, including rock mechanics, in-situ stress distribution, fracture properties, and frac treatment parameters. The solving process of this model was accelerated by classifying the calculation nodes on the extending direction of the fracture by equal pressure gradients, and solving the geometrical parameters prior to the iteration fitting flow distribution. With the initiation and propagation criterion as the bases for the propagation of branch fractures, this method decreased the iteration times through eliminating the fitting of the fracture length in conventional 3D fracture simulation. The simulation results indicated that the formation with abundant natural fractures and smaller in-situ stress difference is sufficient conditions for fracture network development. If the pressure in the hydraulic fractures can be kept at a high level by temporary sealing or diversion, the branch fractures will propagate further with minor curvature radius, thus enlarging the reservoir stimulation area. The simulated shape of fracture network can be well matched with the field microseismic mapping in data point range and distribution density, validating the accuracy of this model.

  19. Comminuted Distal Radial Fracture with Large Rotated Palmar Medial Osteochondral Fragment in the Joint.

    Science.gov (United States)

    Gökkus, Kemal; Sagtas, Ergin; Kesgin, Engin; Aydin, Ahmet Turan

    2018-01-01

    Intra-articular distal radius fractures have long been massively discussed in the literature, but regarding to fractures that possess rotated volar medial fragment in the joint a few amount papers has been written. In this article, we would like to emphasize the significance of the rotated palmar medial (lunate facet) fragment. A 39-year-old man fell from a height of about 3 m and landed on his right outstretched hand; within 40 min, he arrived at our clinic presenting with a severe pain and swelling in his right wrist. Initial X-rays of the wrist revealed dorsal subluxation of the radiocarpal joint with dorsal comminution of the radial articular surface and fracture of the radial styloid process, with (nearly inverted) ~ 140-150° rotation of the palmar medial fragment. With an additional volar approach, the fragment reduced and stabilized with two K-wires and wrist immobilized in external fixator. The patient returned to daily activities without any discomfort and pain after the 1 year from the surgery. Overlooking of palmar rotated osteochondral fragment will cause deficiency to build proper pre-operative strategy to approach the reduction of the fragment. The incompetence of reduction will deteriorate the articular surface and lead to early osteoarthritis of the wrist. The surgeon should detect this fragment and should be familiar with volar approaches of the wrist. Above average surgical experience would be needed for successful reduction.

  20. Open Reduction and Internal Fixation of displaced Supracondylar Fractures of Humerus with Crossed K-wires via Medial Approach

    Directory of Open Access Journals (Sweden)

    S Hussain

    2014-07-01

    Full Text Available This study aimed at evaluating the medial approach for open reduction and internal fixation of Gartland type 3 displaced supracondylar fractures of humerus in children. A prospective, single centre study of on displaced supracondylar humerus fractures in 42 children was carried out at our institute. All fractures were managed with open reduction and internal fixation with crossed K-wires via medial approach. The mean follow-up was 12 months and patients were assessed according to Flynn’s criteria. No patients had post-operative ulnar nerve injury. Cubitus varus was not seen in any patient. Superficial pin tract infection occurred in three patients that subsided with anti-septic dressings and antibiotics. No deep infection occurred. 88.09 % patients showed satisfactory results as per Flynn’s criteria. The medial approach provides an excellent view of the supracondylar area. The approach is convenient due to a lower risk for ulnar nerve injury and better acceptability of the medial incisional scar.

  1. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  2. Comparative study of the prognosis of an extracorporeal reduction and a closed treatment in mandibular condyle head and/or neck fractures.

    Science.gov (United States)

    Park, Jung-Min; Jang, Yong-Wook; Kim, Seong-Gon; Park, Young-Wook; Rotaru, Horatiu; Baciut, Grigore; Hurubeanu, Lucia

    2010-12-01

    The objective of this study was a comparison of the prognosis between an extracorporeal reduction technique and closed treatment of a mandibular condyle fracture. The relationship between condylar resorption and several clinical variables was also studied. Seventy-one patients who had a mandibular condyle fracture took part in this study. Thirty-five patients (female: 7, male: 28, age: 30.46 ± 14.27 years) were treated by extracorporeal reduction, and 36 patients (male: 24, female: 12, age: 24.28 ± 9.99 years) were treated using a closed treatment. The presence of complications such as condylar resorption, malocclusion, nerve disorder, and disc displacement was evaluated with panoramic radiographs and clinical examinations 12 months after treatment. The relationships between the complications and other clinical variables were evaluated statistically. The anatomic site and fracture type were closely related to condyle resorption in the bivariate analysis. Condylar head fractures showed significantly higher condyle resorption than condylar neck fractures (P = .023). A complex or compound fracture showed significantly higher condyle resorption compared with a simple fracture (P = .006). Patients who had a complex/compound fracture were 34.366 times more likely to have condyle resorption compared with those who had a simple fracture (P = .002). The patient's age and treatment method were also significant predictors for condyle resorption. Fracture type was the strongest predictor of condylar resorption. Because treatment method and patient age were also related to the prognosis, the optimal treatment for mandibular condylar head and/or neck fractures should be individualized according to the patient's condition. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Is Closed Manipulative Reduction and Percutaneous Kirschner Wiring of Supracondylar Humeral Fracture in Children as Day-Care Surgery a Safe Procedure ?

    Directory of Open Access Journals (Sweden)

    Ashok R Nayak

    2013-07-01

    Full Text Available INTRODUCTION: Supracondylar fracture of the humerus is a common injury in children. It accounts for 60% of fractures around the elbow children. If the fracture is not treated properly it may give rise to many complications like malunion, Volkmann’s ischemic contracture, nerve injury, arterial injury, skin slough, heterotopic bone formation , and stiffness of elbow. The management of displaced supracondylar fracture of the elbow is one of the most difficult of the many fractures seen in children. The purpose of the study was to evaluate the anatomical and functional results of treatment of supracondylar fractures of humerus with closed reduction and percutaneous ‘K’ wire fixation as a day care procedure and record associated complications, thus decreasing the cost of treating these fractures and hospitalization. METHODS: Fifty displaced closed extension type supracondylar fractures (Gartland’s type III of the humerus in children were treated by closed reduction and percutaneous fixation with Kirschner wires. All the patients selected for this study had been treated in a day care unit and were discharged in the same evening and followed up at 3 and 6 weeks and 3 months. Open fractures, fractures with neurovascular complications and children older than 15 yrs were excluded. The final results were evaluated by Flynn’s criteria. RESULTS: The majority (72%, of the patients had fracture displaced posteomedially, Fourty one of the fifty patients had satisfactory results. The majority of the patients were male, and the average age was 8-9 years. CONCLUSION: Percutaneous fixation of supracondylar humerus done as a day care procedure is an acceptable modality of treatment and reduces the duration of hospital stay for the patient.

  4. Periodic Hydraulic Testing for Discerning Fracture Network Connections

    Science.gov (United States)

    Becker, M.; Le Borgne, T.; Bour, O.; Guihéneuf, N.; Cole, M.

    2015-12-01

    Discrete fracture network (DFN) models often predict highly variable hydraulic connections between injection and pumping wells used for enhanced oil recovery, geothermal energy extraction, and groundwater remediation. Such connections can be difficult to verify in fractured rock systems because standard pumping or pulse interference tests interrogate too large a volume to pinpoint specific connections. Three field examples are presented in which periodic hydraulic tests were used to obtain information about hydraulic connectivity in fractured bedrock. The first site, a sandstone in New York State, involves only a single fracture at a scale of about 10 m. The second site, a granite in Brittany, France, involves a fracture network at about the same scale. The third site, a granite/schist in the U.S. State of New Hampshire, involves a complex network at scale of 30-60 m. In each case periodic testing provided an enhanced view of hydraulic connectivity over previous constant rate tests. Periodic testing is particularly adept at measuring hydraulic diffusivity, which is a more effective parameter than permeability for identify the complexity of flow pathways between measurement locations. Periodic tests were also conducted at multiple frequencies which provides a range in the radius of hydraulic penetration away from the oscillating well. By varying the radius of penetration, we attempt to interrogate the structure of the fracture network. Periodic tests, therefore, may be uniquely suited for verifying and/or calibrating DFN models.

  5. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures.

    Science.gov (United States)

    Tang, Xin; Liu, Lei; Tu, Chong-qi; Li, Jian; Li, Qi; Pei, Fu-xing

    2014-07-01

    The timing of surgery for osteosynthesis of type C pilon (AO/OTA) fractures remains controversial. The aim of this study was to determine the outcome of early and delayed open reduction and internal fixation (ORIF) for treating closed type C pilon fractures. Forty-six patients with closed type C pilon fractures matched according to age, gender, soft tissue conditions, and fracture pattern were divided into group A (early group: underwent surgery within 36 hours of the injury) or group B (delayed group: underwent surgery 10 days to 3 weeks postinjury after the soft tissue swelling subsided). In the delayed group, 9 patients were treated first by temporary external fixation. All the closed fractures were managed by ORIF with locking plates. At follow-up, the clinical and radiographic results were retrospectively analyzed. The mean follow-up time was 25.8 months (range, 14 to 48 months) in group A and 26.0 months (range, 15 to 44 months) in group B. There was no significant difference (P > .05) between the 2 groups regarding the rate of soft tissue complication, the rate of fracture union, and the final functional score. The patients in group A had a significantly shorter mean time to fracture union (21.5 ± 4.0 weeks vs 23.3 ± 3.7 weeks, P fractures can be safe and effective, with similar rates of wound complication, fracture union, and final good functional recovery but shorter operative time, union time, and hospital stay. These results favorably compare with delayed ORIF treatment. Level III, retrospective comparative study. © The Author(s) 2014.

  6. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    Science.gov (United States)

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  7. Stress fractures in athletes

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Wolf, C.; Gruber, H.; Czermak, B.V.; Mallouhi, A.; Jaschke, W.; Gabriel, M.

    2002-01-01

    Stress fractures may pose a diagnostic dilemma for radiologists since they are sometimes difficult to demonstrate on plain films and may simulate a tumour. They were first described in military personnel and professional athletes. Recently, there is an increasing incidence in the general population due to increasing sportive activities. Stress fractures occur most often in the lower extremities, especially in the tibia, the tarsal bone, the metatarsal bone, the femur and the fibula. In the upper extremities, they are commonly found in the humerus, the radius and the ulna. Some fractures of the lower extremities appear to be specific for particular sports, for example, fractures of the tibia affect mostly distance runners. Whereas stress fractures of the upper extremities are generally associated with upper limb-dominated sports. A correct diagnosis requires a careful clinical evaluation. The initial plain radiography may be normal. Further radiological evaluation could be performed by means of computerised tomography, magnetic resonance imaging and bone scanning. The latter two techniques are especially helpful for establishing a correct initial diagnosis. (orig.) [de

  8. A Fracture Decoupling Experiment

    Science.gov (United States)

    Stroujkova, A. F.; Bonner, J. L.; Leidig, M.; Ferris, A. N.; Kim, W.; Carnevale, M.; Rath, T.; Lewkowicz, J.

    2012-12-01

    Multiple observations made at the Semipalatinsk Test Site suggest that conducting nuclear tests in the fracture zones left by previous explosions results in decreased seismic amplitudes for the second nuclear tests (or "repeat shots"). Decreased seismic amplitudes reduce both the probability of detection and the seismically estimated yield of a "repeat shot". In order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fractured rocks, Weston Geophysical Corp., in collaboration with Columbia University's Lamont Doherty Earth Observatory, conducted a multi-phase Fracture Decoupling Experiment (FDE) in central New Hampshire. The FDE involved conducting explosions of various yields in the damage/fracture zones of previously detonated explosions. In order to quantify rock damage after the blasts we performed well logging and seismic cross-hole tomography studies of the source region. Significant seismic velocity reduction was observed around the source regions after the initial explosions. Seismic waves produced by the explosions were recorded at near-source and local seismic networks, as well as several regional stations throughout northern New England. Our analysis confirms frequency dependent seismic amplitude reduction for the repeat shots compared to the explosions in un-fractured rocks. The amplitude reduction is caused by pore closing and/or by frictional losses within the fractured media.

  9. Transstyloid, transscaphoid, transcapitate fracture: a variant of scaphocapitate fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2014-01-01

    Transstyloid, transscaphoid, transcapitate fractures are uncommon. We report the case of a 28-year-old man who sustained this fracture following direct trauma. The patient was successfully treated by open reduction internal fixation of the scaphoid and proximal capitate fragment, with a good clinical outcome at 1-year follow-up. This pattern is a new variant of scaphocapitate fracture as involves a fracture of the radial styloid as well.

  10. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    Science.gov (United States)

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  11. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    Directory of Open Access Journals (Sweden)

    Samir Joshi

    2015-01-01

    Full Text Available Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  12. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    Science.gov (United States)

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  13. Does osteoporosis increase complication risk in surgical fracture treatment? A protocol combining new endpoints for two prospective multicentre open cohort studies

    Directory of Open Access Journals (Sweden)

    Marent Marta

    2010-11-01

    Full Text Available Abstract Background With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation. Methods/Design The studies were planned using a prospective multicentre open cohort design and included patients between 50 and 90 years of age. Distal radius and proximal humerus fractures were treated with locking compression 2.4 mm and proximal humerus internal locking plates, respectively. Follow-up examinations were planned for 6 weeks, 3 and 12 months as well as a telephone interview at 6 months. The primary outcome focuses on the occurrence of at least one local bone quality related complication. Local bone quality is determined by measuring bone mineral density and bone mineral content at the contralateral radius. Primary complications are categorised according to predefined factors directly related to the bone/fracture or the implant/surgical technique. Secondary outcomes include the documentation of soft tissue/wound or general/systemic complications, clinical assessment of range of motion, and patient-rated evaluations of upper limb function and quality of life using both objective and subjective measures. Discussion The prospective multicentre open cohort studies will determine the value of local bone quality as measured by bone mineral density and content, and compare the quality of local bone of patients who experience a complication (cases following surgery with that of patients who do not (controls. These measurements are novel and

  14. Notch constraint effects on the dynamic fracture toughness of an unaged beta titanium alloy

    International Nuclear Information System (INIS)

    Rack, H.J.

    1975-01-01

    The influence of notch included angle and root radius on the apparent dynamic fracture toughness of an unaged metastable beta titanium alloy, Ti--3Al--8V--6Cr--4Zr--4Mo, has been examined. The apparent fracture toughness, K/sub Id/(rho), increases with both notch radius, rho and included angle, ω. These results have been compared with the theoretical predictions of Tetelman, et al. and Smith. The comparisons show that neither theory accurately describes the effect of varying notch constraint on the apparent dynamic fracture toughness. Although preliminary considerations indicate that qualitative descriptions of notch acuity effects may be given by recent finite element analysis of the stress and strain distributions below a notch root, there is presently no quantitative basis for determining the true dynamic fracture toughness of materials from the results of blunt notch experiments. (auth)

  15. Mode II brittle fracture: recent developments

    Directory of Open Access Journals (Sweden)

    A. Campagnolo

    2017-10-01

    Full Text Available Fracture behaviour of V-notched specimens is assessed using two energy based criteria namely the averaged strain energy density (SED and Finite Fracture Mechanics (FFM. Two different formulations of FFM criterion are considered for fracture analysis. A new formulation for calculation of the control radius Rc under pure Mode II loading is presented and used for prediction of fracture behaviour. The critical Notch Stress Intensity Factor (NSIF at failure under Mode II loading condition can be expressed as a function of notch opening angle. Different formulations of NSIFs are derived using the three criteria and the results are compared in the case of sharp V-notched brittle components under in-plane shear loading, in order to investigate the ability of each method for the fracture assessment. For this purpose, a bulk of experimental data taken from the literature is employed for the comparison among the mentioned criteria

  16. Open reduction and internal fixation of dislocated condylar fractures in children: long-term clinical and radiologic outcomes.

    Science.gov (United States)

    Deleyiannis, Frederic W-B; Vecchione, Lisa; Martin, Brian; Jiang, Shao; Sotereanos, George

    2006-11-01

    The purpose of this study was to investigate the long-term clinical and radiologic outcomes of treating dislocated condylar fractures sustained in childhood with open reduction and internal fixation (ORIF). Six children 14 years or younger with a condylar neck or subcondylar fracture with dislocation of the condyle from the glenoid fossa were treated with ORIF. Patients were followed for 27 to 92 months post-ORIF (mean: 67.6 months) with routine clinical and radiologic examinations. On the dislocated side, all patients radiographically showed signs of remodeling of the condylar process and shortening of the ramus. Subsequent to their fractures, 3 patients were classified with Angle class II malocclusion, retrognathism, and deviation of the mandibular symphysis. Four patients had objective and/or subjective signs of temporomandibular (TMJ) dysfunction. Until open surgery demonstrates a consistent functional advantage, nonsurgical management should be considered the first treatment option for the dislocated pediatric condylar fracture.

  17. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    Science.gov (United States)

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  18. Management of Hip Fractures in Lateral Position without a Fracture Table

    Directory of Open Access Journals (Sweden)

    Hamid Pahlavanhosseini

    2014-09-01

    Full Text Available Background:  Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays’ dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view.  Methods:  40 hip fractures (31 trochanteric and 9 femoral neck fractures were operated in lateral position between Feb 2006 and Oct 2012. Age, gender, fracture classification, operation time, intra-operation blood loss, reduction quality, and complications were extracted from patients’ medical records. The mean follow-up time was 30.78±22.73 months (range 4-83. Results: The mean operation time was 76.50 ± 16.88 min (range 50 – 120 min.The mean intra-operative blood loss was 628.75 ± 275.00 ml (range 250-1300ml. Anatomic and acceptable reduction was observed in 95%of cases. The most important complications were malunion (one case in trochanteric group, avascular necrosis of oral head and nonunion (each one case in femoral neck group.  Conclusions:  It sounds that reduction and fixation of hip fractures in lateral position with fluoroscopy in just anteroposterior view for small rural hospitals may be executable and probably safe.

  19. MRI diagnosis of trapped periosteum following incomplete closed reduction of distal tibial Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Raman, Subha; Wallace, E.C.

    2011-01-01

    Irreducible fracture of the distal tibial physis due to interposed soft tissue including periosteum is well documented in the orthopedic literature but is uncommon. This condition has been associated with subsequent growth disturbance and requires open reduction. There are very few prior reports of MRI depiction of soft tissue interposition and none of periosteal interposition in the distal tibial physis. This is a relatively common location of physeal injury and related growth disturbance. We present a case of periosteum trapped in the distal tibial physis, diagnosed on MRI, in a Salter-Harris II fracture and its management implications. (orig.)

  20. Fractured long bones in a term infant delivered by cesarian section

    International Nuclear Information System (INIS)

    Kaplan, M.; Dollberg, M.; Wajntraub, G.; Itzchaki, M.

    1987-01-01

    A term infant was delivered uneventfully by repeat cesarian section. At the age of 1 week there was clinical and radiographic evidence of fractures of the left tibia and right radius. The fractures most likely occurred during the cesarian section. Birth trauma should not be excluded on the basis of cesarian section delivery. (orig.)

  1. Clinical comparison between the retromandibular approach for reduction and fixation and endoscope-assisted open reduction and internal fixation for mandibular condyle fractures.

    Science.gov (United States)

    Nogami, Shinnosuke; Takahashi, Tetsu; Yamauchi, Kensuke; Miyamoto, Ikuya; Kaneuji, Takeshi; Yamamoto, Noriaki; Yoshiga, Daigo; Yamashita, Yoshihiro

    2012-11-01

    Endoscope-assisted transoral open reduction and internal fixation (EAORIF) for mandibular condyle fractures has recently become popular because it is minimally invasive, provides excellent visibility without a large incision, and reduces surgical scarring and the risk of facial nerve injury. This report describes a retrospective clinical study that compared certain clinical parameters, including postoperative function, between the retromandibular (RM) approach and EAORIF. Fifteen patients were treated by the RM approach, whereas 15 underwent EAORIF between July 2006 and September 2011 at Kyushu Dental College, Japan. Clinical indices comprised fracture line, fracture type, number of plates used, surgical duration, bleeding amount, and functional items, including maximum interincisal opening, mandibular deviation on the opening pathway, malocclusion, facial paresthesia, and temporomandibular joint pain and clicking. The areas subjected to either approach included lower neck and subcondyle. The RM approach was used for mandibular condyle fractures with dislocation of a small bone segment. Both groups used 2 plates in all cases. Surgical duration, maximum interincisal opening, mandibular deviation, occlusion, and temporomandibular joint function at 6 months after surgery were comparable between groups. The average bleeding amount in the EAORIF group was greater than in the RM group. One patient from the RM group developed facial paresthesia that persisted for 6 months after surgery. It was concluded that surgical treatment was suitable for fractures of the lower neck and subcondylar. Both procedures showed good results in the functional items of this study.

  2. Effects of root radius, stress, crack growth and rate on fracture instability

    Energy Technology Data Exchange (ETDEWEB)

    McClintock, F A

    1965-01-01

    Of various criteria for fracture at the root of a notch, the energy, local stress, and displacement criteria have limited validity. More appropriate is the history of both stress and strain over a small region ahead of the crack, as required for fracture by the coalescence of holes. Expressions are given for crack initiation, growth, and subsequent instability in anti-plane strain of a nonhardening material. Instability is shown to depend primarily on those strain increments arising from crack growth at constant load rather than on those from increasing load at constant crack length. Thus final instability conditions are similar for single and double- ended cracks, round notches, and cracks cut under constant load. Round notches may give instability, restabilization and final instability. The growth and coalescence of holes in front of a crack in a linearly viscous material is studied for both tensile and anti-plant-strain cracks. The absence of residual strain eliminates instability, but the crack continually accelerates. (26 refs.)

  3. Formability of dual-phase steels in deep drawing of rectangular parts: Influence of blank thickness and die radius

    Science.gov (United States)

    López, Ana María Camacho; Regueras, José María Gutiérrez

    2017-10-01

    The new goals of automotive industry related with environment concerns, the reduction of fuel emissions and the security requirements have driven up to new designs which main objective is reducing weight. It can be achieved through new materials such as nano-structured materials, fibre-reinforced composites or steels with higher strength, among others. Into the last group, the Advance High Strength Steels (AHSS) and particularly, dual-phase steels are in a predominant situation. However, despite of their special characteristics, they present issues related to their manufacturability such as springback, splits and cracks, among others. This work is focused on the deep drawing processof rectangular shapes, a very usual forming operation that allows manufacturing several automotive parts like oil pans, cases, etc. Two of the main parameters in this process which affect directly to the characteristics of final product are blank thickness (t) and die radius (Rd). Influence of t and Rd on the formability of dual-phase steels has been analysed considering values typically used in industrial manufacturing for a wide range of dual-phase steels using finite element modelling and simulation; concretely, the influence of these parameters in the percentage of thickness reduction pt(%), a quite important value for manufactured parts by deep drawing operations, which affects to its integrity and its service behaviour. Modified Morh Coulomb criteria (MMC) has been used in order to obtain Fracture Forming Limit Diagrams (FFLD) which take into account an important failure mode in dual-phase steels: shear fracture. Finally, a relation between thickness reduction percentage and studied parameters has been established fordual-phase steels, obtaining a collection of equations based on Design of Experiments (D.O.E) technique, which can be useful in order to predict approximate results.

  4. Open versus closed reduction: mandibular condylar fractures in children.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2012-09-01

    The purpose of the study was to review the literature regarding the evolution of current thoughts on management of mandibular condylar fractures (MCFs) in children. An electronic search in PubMed was undertaken in May 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies published in English or German from the last 20 years (from 1992 onwards) reporting clinical series of MCFs in children and adolescents until the age of 18. The search strategy initially identified 542 studies. The references from 1992 onwards totaled 339 articles. Twenty-seven studies were identified without repetition within the selection criteria. Additional hand-searching yielded two additional papers. Pediatric MCFs require thoughtful consideration in management to avoid significant growth disturbance. Early treatment is indicated in order to improve the chances for favorable development. Long-term follow-up is required, in order to properly treat late complications that may appear. Coronal computed tomography is helpful in substantiating the correct final diagnosis. Many studies show that conservative treatment (CTR) has satisfactory long-term outcome of jaw function, occlusion, and facial esthetics, despite a high frequency of radiological aberrations. Surgery before puberty should be reserved for exceptional cases such as missile injuries, in cases with extensive dislocation and lack of contact between the fragments, in cases with multiple midfacial fractures, in which the mandible has to serve as a guide to reposition the midfacial bones, and in cases which the dislocation of the fractured stump creates a functional impediment that cannot be resolved by CTR. As the craniofacial skeleton becomes more adult-like in its form at about 12 years of age, the decreased remodeling capacity in the adolescents may occasionally result in abnormally shaped condylar heads or shortened ramus heights that may

  5. Treatment of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures.

    Science.gov (United States)

    Xu, Xiaofeng; Shi, Jun; Xu, Bing; Dai, Jiewen; Zhang, Shilei

    2015-03-01

    To evaluate the treatment methods of mandibular symphyseal fracture combined with dislocated intracapsular condylar fractures (MSF&DICF) and to compare the effect of different treatment methods of condylar fractures. Twenty-eight patients with MSF&DICF were included in this study. Twenty-two sites were treated by open reduction, and all the medial condylar fragments were fixed with titanium screws; whereas the other 22 sites underwent close treatment. The surgical effect between these 2 groups was compared based on clinical examination and radiographic examination results. Seventeen of 22 condyle fractures were repositioned in the surgery group, whereas 4 of 22 condyle fractures were repositioned in the close treatment group. Statistical difference was observed between these 2 groups (P condyle fractures should be treated by surgical reduction with the maintenance of the attachment of lateral pterygoid muscle, which is beneficial to repositioning the dislocated condyle to its original physiological position, to closure of the mandibular lingual gap, to restore the mandibular width.

  6. Evaluation of fracture mode for local wall-thinned pipes

    International Nuclear Information System (INIS)

    Herman, Irwan; Suzuki, Tomohisa; Sato, Yasumoto; Meshii, Toshiyuki

    2007-01-01

    In this study, by referring to our burst pressure tests results, firstly, the effects of flaw length δ z and pipe size (mean radius R) on burst pressure p f were investigated by using Finite Element Method (FEM). Then, fracture mode evaluation was made by using history data of strain ratio ε z /ε θ along with load increment. Furthermore, the effect of flaw depth t 1 on fracture mode was studied and finally, the evaluation method of fracture mode for local wall-thinned pipes was introduced. (author)

  7. Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

    Science.gov (United States)

    Ahrens, Philipp; Sandmann, Gunther; Bauer, Jan; König, Benjamin; Martetschläger, Frank; Müller, Dirk; Siebenlist, Sebastian; Kirchhoff, Chlodwig; Neumaier, Markus; Biberthaler, Peter; Stöckle, Ulrich; Freude, Thomas

    2012-09-01

    Fractures of the tibial plateau are among the most severe injuries of the knee joint and lead to advanced gonarthrosis if the reduction does not restore perfect joint congruency. Many different reduction techniques focusing on open surgical procedures have been described in the past. In this context we would like to introduce a novel technique which was first tested in a cadaver setup and has undergone its successful first clinical application. Since kyphoplasty demonstrated effective ways of anatomical correction in spine fractures, we adapted the inflatable instruments and used the balloon technique to reduce depressed fragments of the tibial plateau. The technique enabled us to restore a congruent cartilage surface and bone reduction. In this technique we see a useful new method to reduce depressed fractures of the tibial plateau with the advantages of low collateral damage as it is known from minimally invasive procedures.

  8. Alendronate for fracture prevention in postmenopause.

    Science.gov (United States)

    Holder, Kathryn K; Kerley, Sara Shelton

    2008-09-01

    Osteoporosis is an abnormal reduction in bone mass and bone deterioration leading to increased fracture risk. Alendronate (Fosamax) belongs to the bisphosphonate class of drugs, which act to inhibit bone resorption by interfering with the activity of osteoclasts. To assess the effectiveness of alendronate in the primary and secondary prevention of osteoporotic fractures in postmenopausal women. The authors searched Central, Medline, and EMBASE for relevant randomized controlled trials published from 1966 to 2007. The authors undertook study selection and data abstraction in duplicate. The authors performed meta-analysis of fracture outcomes using relative risks, and a relative change greater than 15 percent was considered clinically important. The authors assessed study quality through reporting of allocation concealment, blinding, and withdrawals. Eleven trials representing 12,068 women were included in the review. Relative and absolute risk reductions for the 10-mg dose were as follows. For vertebral fractures, a 45 percent relative risk reduction was found (relative risk [RR] = 0.55; 95% confidence interval [CI], 0.45 to 0.67). This was significant for primary prevention, with a 45 percent relative risk reduction (RR = 0.55; 95% CI, 0.38 to 0.80) and 2 percent absolute risk reduction; and for secondary prevention, with 45 percent relative risk reduction (RR = 0.55; 95% CI, 0.43 to 0.69) and 6 percent absolute risk reduction. For nonvertebral fractures, a 16 percent relative risk reduction was found (RR = 0.84; 95% CI, 0.74 to 0.94). This was significant for secondary prevention, with a 23 percent relative risk reduction (RR = 0.77; 95% CI, 0.64 to 0.92) and a 2 percent absolute risk reduction, but not for primary prevention (RR = 0.89; 95% CI, 0.76 to 1.04). There was a 40 percent relative risk reduction in hip fractures (RR = 0.60; 95% CI, 0.40 to 0.92), but only secondary prevention was significant, with a 53 percent relative risk reduction (RR = 0.47; 95% CI

  9. Mandible Fractures.

    Science.gov (United States)

    Pickrell, Brent B; Serebrakian, Arman T; Maricevich, Renata S

    2017-05-01

    Mandible fractures account for a significant portion of maxillofacial injuries and the evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Understanding appropriate surgical management can prevent complications such as malocclusion, pain, and revision procedures. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. In this article, the authors review the diagnostic evaluation, treatment options, and common complications of mandible fractures. Special considerations are described for pediatric and atrophic mandibles.

  10. Open Reduction With K-Wire Stabilization of Fracture Dislocations of the Mandibular Condyle: A Retrospective Review.

    Science.gov (United States)

    Haghighi, Kayvon; Manolakakis, Manolis G; Balog, Connor

    2017-06-01

    The aim of this study was to determine the feasibility of direct transcortical stabilization of fracture dislocations of the mandibular condyle (FDMCs) using narrow-diameter non-threaded Kirschner wire (K-wire). This retrospective review reports on the treatment outcomes for 12 patients (15 fractures) with FDMCs treated with open reduction using transcortical 0.027-inch K-wire stabilization. Postoperative parameters of relevance included infection, facial nerve function, hardware removal, mandibular range of motion, and radiographic determination of fracture union. Three patients had bilateral FDMCs and 9 had unilateral FDMCs (age range at time of injury, 14 to 72 yr; mean age, 32 yr). Postoperative follow-up ranged from 6 weeks to 2 years. Four patients required removal of K-wire hardware for different reasons. K-wires were removed because of infection in 1 patient. Another patient required removal because of migration of the pin into the joint space. One pin was removed electively and another was removed for nonspecific postoperative symptoms that resolved after pin removal. Persistent facial nerve deficit was observed in 1 patient. Open reduction with transcortical K-wire stabilization can achieve satisfactory outcomes for the treatment of FDMC. Further investigation is needed in determining the efficacy of this fixation technique in the management of FDMC. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Analysis of Flow Behavior for Acid Fracturing Wells in Fractured-Vuggy Carbonate Reservoirs

    Directory of Open Access Journals (Sweden)

    Mingxian Wang

    2018-01-01

    Full Text Available This study develops a mathematical model for transient flow analysis of acid fracturing wells in fractured-vuggy carbonate reservoirs. This model considers a composite system with the inner region containing finite number of artificial fractures and wormholes and the outer region showing a triple-porosity medium. Both analytical and numerical solutions are derived in this work, and the comparison between two solutions verifies the model accurately. Flow behavior is analyzed thoroughly by examining the standard log-log type curves. Flow in this composite system can be divided into six or eight main flow regimes comprehensively. Three or two characteristic V-shaped segments can be observed on pressure derivative curves. Each V-shaped segment corresponds to a specific flow regime. One or two of the V-shaped segments may be absent in particular cases. Effects of interregional diffusivity ratio and interregional conductivity ratio on transient responses are strong in the early-flow period. The shape and position of type curves are also influenced by interporosity coefficients, storativity ratios, and reservoir radius significantly. Finally, we show the differences between our model and the similar model with single fracture or without acid fracturing and further investigate the pseudo-skin factor caused by acid fracturing.

  12. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation.

    Science.gov (United States)

    Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka

    2016-01-01

    Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.

  13. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2014-11-01

    Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

  14. Changing incidence and residual lifetime risk of common osteoporosis-related fractures

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; Lund, B

    1993-01-01

    1735 fractures of the distal radius, 747 fractures of the proximal humerus, 878 cervical and 635 trochanteric hip fractures were included. In men 273 cervical and 232 trochanteric hip fractures were included. The fractures were registered during the period 1976 to 1984 and changes in age.......05) during the observation period, while no significant decrease was found in the incidence of trochanteric fractures. No significant changes in incidence were observed in women with radial or humeral fractures, or in men with hip fractures. A women 60 years old with a life expectancy of 81 years had......Changes in incidence and lifetime risk of fractures are of major importance in the epidemiology of osteoporosis. We focused on hip fractures in women and men and on radial and humeral fractures in women. The study subjects comprised 4500 women and men 20 years old or more with fractures. In women...

  15. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    Science.gov (United States)

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  16. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    OpenAIRE

    Samir Joshi; Rajesh Kshirsagar; Akshay Mishra; Rahul Shah

    2015-01-01

    Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plate...

  17. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    Science.gov (United States)

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  18. A PROSPECTIVE STUDY ON FUNCTIONAL OUTCOME OF HUMERUS SHAFT FRACTURES TREATED WITH OPEN REDUCTION AND INTERNAL FIXATION WITH DYNAMIC COMPRESSION PLATE AND SCREWS

    Directory of Open Access Journals (Sweden)

    Vidyadhar S. Donimath

    2017-12-01

    Full Text Available BACKGROUND Fracture of the humerus shaft accounts to 3% to 5% of all fractures. Majority of the fractures are unstable due to distraction force of the gravity in the upper limb and strong muscle contraction leading to displacement. Internal fixation and early mobilisation is more stressed on than splinting and prolonged immobilisation to allow earlier mobilisation and rapid return to work. The aim of the study was to study the union rates and the functional outcome and complications associated with shaft humerus fractures in KIMS Hospital. MATERIALS AND METHODS A prospective study which was carried out from October 2015 to September 2017 in Karnataka Institute of Medical Sciences, Hubballi, Karnataka State, India. In this study period, 25 cases of fracture shaft of the humerus were treated by open reduction and internal fixation using DCP. Skeletally mature patients with fresh humerus diaphysis fractures were included in the study. Pathological fractures and Tscherne grade 2 and above, Gustilo Anderson type2 and above were excluded from the study. RESULTS In our series of 25 cases, there were 21 men and 4 women with average age of 42.5 years. Sixteen (64% cases were due to RTA and with predominance of right side. Transverse fractures were most common that is 15 (60% patients. Eleven (31% cases were having associated injuries. 92% of the fractures united with good to excellent outcome. There were 2 (8% cases of non-union due to infection and comminution. CONCLUSION Open reduction and internal fixation with dynamic compression plate is still the standard treatment of choice for fracture shaft of humerus achieving excellent to good functional outcome.

  19. Study protocol: non-displaced distal radial fractures in adult patients: three weeks vs. five weeks of cast immobilization: a randomized trial.

    Science.gov (United States)

    Bentohami, Abdelali; de Korte, Niels; Sosef, Nico; Goslings, Johan Carel; Bijlsma, Taco; Schep, Niels

    2014-01-20

    Up to 30% of patients suffer from long-term functional restrictions following conservative treatment of distal radius fractures. Whether duration of cast immobilisation influences functional outcome remains unclear. The aim of the study is to evaluate whether the duration of immobilization of non or minimally displaced distal radial fractures can be safely reduced. We will compare three weeks of plaster cast immobilization with five weeks of plaster cast immobilization in adult patient with non or minimally displaced distal radial fractures. a prospective randomized clinical trial. adult (>18 years) (independent in activities of daily living) patients with a non/minimal displaced distal radius fracture (dorsal angulation 15°, ulnar positive variance immobilization versus five weeks of plaster cast immobilization.Main study parameters: primary outcome parameters: Patient related wrist evaluation (PRWE) Quick Disability of Arm, Shoulder and Hand (QUICKDASH) score after a one year follow-up, and secondary parameters: range of motion, pain level (VAS) and complications. The expectation of this study is that shorter duration of plaster cast immobilisation is beneficial for the patient with a distal radius fracture. This risk of specific complications is low and generally similar in both treatment options. Moreover, the burden of the study is not much higher compared to standard treatment. Follow-up is standardized according to current trauma guidelines. Literature indicates that both treatment options from the study are accepted for displaced distal radius fractures. No clear advantage for one treatment options is found at present in the literature, although there is no level I evidence present. This trial will provide level-1 evidence for the comparison of consolidation and functional outcome between two treatment options for non-displaced distal radial fractures. The gathered data may support the development of a clinical guideline for conservative treatment of

  20. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  1. Pathological fracture in non-ossifying fibroma with histological features simulating aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Hoeffel, C.; Mainard, L.; Hoeffel, J.C.; Panuel, M.; Plenat, F.

    1999-01-01

    A 12-year-old-girl presented with a fracture of an osteolytic lesion of the distal radius. A 7-year-old girl presented with a fracture of an osteolytic lesion of the femoral shaft. In both cases it was a non-ossifying fibroma with fracture misdiagnosed at pathology as aneurysmal bone cyst. Fractures through non-ossifying fibromas may alter the histological pattern of the initial lesion in two ways: firstly, by the presence of blood pigments due to the fracture, and secondly, by formation of new bone. Radiological-pathological correlation is essential to avoid histological errors after pathological fracture in a non-ossifying fibroma. (orig.)

  2. Tibiofibula Transposition in High-Energy Fractures

    Directory of Open Access Journals (Sweden)

    Peter R. Loughenbury

    2016-01-01

    Full Text Available We report two cases of failed attempts at closed reduction of high-energy tibial fractures with an associated fibula fracture. The first case was a 39-year-old male involved in high-speed motorbike collision, while the second was a 14-year-old male who injured his leg following a fall of three metres. Emergency medical services at the scenes of the accidents reported a 90-degree valgus deformity of the injured limb and both limbs were realigned on scene and stabilized. Adequate alignment of the tibia could not be achieved by manipulation under sedation or anaesthesia. Open reduction and exposure of the fracture sites revealed that the distal fibula fragment was “transposed” and entrapped in the medulla of the proximal tibial fragment. Reduction required simulation of the mechanism of injury in order to disengage the fragments and allow reduction. Tibiofibula transposition is a rare complication of high-energy lower limb fractures which has not previously been reported and may prevent adequate closed reduction. Impaction of the distal fibula within the tibial medulla occurs as the limb is realigned by paramedic staff before transfer to hospital. We recommend that when this complication is identified the patient is transferred to the operating room for open reduction and stabilization of the fracture.

  3. Ununited fracture neck of femur treated with closed reduction and internal fixation with cancellous screw and fibular strut graft

    Directory of Open Access Journals (Sweden)

    Singh Daria

    2006-01-01

    Full Text Available Background: Ununited fracture neck of femur in young adults has been tackled in various ways. Methods: Twenty five patients of ununited fracture neck of femur in age group 21-55 years were treated by closed reduction, cancellous screw fixation and fibular strut graft and followed up for 2-6 years. Time gap between injury and operation was 6 weeks to 58 weeks. Five cases were previously fixed with various fixation devices. Results: Osseous union was achieved in 24 cases with average time of 18.16 weeks. Main complication encountered in follow-up was avascular necrosis of femoral head, others were joint stiffness and shortening. Functional end results were good to excellent in 24 cases. Conclusion: Closed reduction with internal fixation by cancellous screw and fibular strut grafting is easy and useful procedure.

  4. Incidence of Treatment for Infection of Buried Versus Exposed Kirschner Wires in Phalangeal, Metacarpal, and Distal Radial Fractures.

    Science.gov (United States)

    Ridley, Taylor J; Freking, Will; Erickson, Lauren O; Ward, Christina Marie

    2017-07-01

    To determine whether there is a difference in the incidence of infection between exposed and buried K-wires when used to treat phalangeal, metacarpal, and distal radius fractures. We conducted a retrospective review identifying all patients aged greater than 16 years who underwent fixation of phalangeal, metacarpal, or distal radius fractures with K-wires between 2007 and 2015. We recorded patient demographic data, fracture location, number of K-wires used, whether K-wires were buried or left exposed, and duration of K-wire placement. A total of 695 patients met inclusion criteria. Surgeons buried K-wires in 207 patients and left K-wires exposed in 488. Infections occurred more frequently in exposed K-wire cases than in buried K-wire ones. Subgroup analysis based on fracture location revealed a significantly increased risk of being treated for infection when exposed K-wires were used for metacarpal fractures. Patients with exposed K-wires for fixation of phalangeal, metacarpal, or distal radius fractures were more likely to be treated for a pin-site infection than those with K-wires buried beneath the skin. Metacarpal fractures treated with exposed K-wires were 2 times more likely to be treated for a pin-site infection (17.6% of exposed K wire cases vs 8.7% of buried K wire cases). Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Combined Volar and Dorsal Approach for Fixation of Comminuted Intra-Articular Distal Radial Fractures.

    Science.gov (United States)

    Medlock, G; Smith, M; Johnstone, A J

    2018-07-01

    Purpose  Multifragmentary intra-articular fractures displaced in multiple planes are a challenge. We use a reproducible technique of fracture and articular reduction using an initial volar approach targeting reduction in the volar lunate facet first with plate and unicortical locking screws. This creates a template for reduction in dorsal fragments through a dorsal approach. Our study investigated the radiological, clinical, and functional outcomes of patients treated with this technique. Materials and Methods  We reviewed the postoperative radiographs and notes of 18 patients that had this method of fixation between the years 2008 and 2015, the mean age being 43. These patients were reviewed functionally on average 2 years and 3 months following their definitive operation. Results  Normal alignment and length to the distal radius were restored with on average a 0.6 mm articular step. The average range of motion was 64% and preservation of grip strength was 71% compared with the uninjured wrist. Functional assessment averages were 29 for both the quick Disabilities of the Arm, Shoulder and Hand (DASH) and for Patient Rated Wrist Evaluation. The modified system of Green and O'Brien had results of good in 10, fair in 7, and poor in 1. With respect to the Gartland and Werley system, three patients had an excellent result, four had a good result, six had a fair result, and five had a poor result. The mean arthritic grading was 1 (grading 0-3) according to Knirk and Jupiter. Conclusion  This reproducible technique provides an option for these devastating fractures providing a functioning wrist with all of the patients returning to their original form of employment.

  6. Exercise-induced rib stress fractures: influence of reduced bone mineral density

    DEFF Research Database (Denmark)

    Vinther, Anders; Kanstrup, Inge-Lis; Christiansen, Erik

    2005-01-01

    study investigated BMD in seven Danish national team rowers with previous rib stress fracture (RSF) and 7 controls (C) matched for gender, age, height, weight and training experience. Total body scan and specific scans of the lumbar spine (L2-L4), femoral neck and distal radius were performed using......Exercise-induced rib stress fractures have been reported frequently in elite rowers during the past decade. The etiology of rib stress fractures is unclear, but low bone mineral density (BMD) has been suggested to be a potential risk factor for stress fractures in weight-bearing bones. The present...... density may be a potential risk factor for the development of exercise-induced rib stress fractures in elite rowers....

  7. Contemporary management of subtrochanteric fractures.

    Science.gov (United States)

    Joglekar, Siddharth B; Lindvall, Eric M; Martirosian, Armen

    2015-01-01

    Cephalomedullary interlocking nails that allow for trochanteric entry and minimally invasive fixation have revolutionized the contemporary management of subtrochanteric fractures with improved union rates and decreased incidence of fixation failure. The most successful alternative to intramedullary fixation remains the angled blade plate. Despite biomechanical superiority of contemporary intramedullary implants to previous intramedullary devices, the importance of achieving and maintaining satisfactory fracture reduction prior to and during hardware insertion cannot be overemphasized. In comminuted and more challenging fractures, additional techniques, such as limited open reduction with clamps and/or cables, can allow for canal restoration and more anatomic reductions prior to and/or during nail insertion. Published by Elsevier Inc.

  8. A remediation performance model for enhanced metabolic reductive dechlorination of chloroethenes in fractured clay till

    Science.gov (United States)

    Manoli, Gabriele; Chambon, Julie C.; Bjerg, Poul L.; Scheutz, Charlotte; Binning, Philip J.; Broholm, Mette M.

    2012-04-01

    A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation efficiency and timeframe. A relatively simple approach is used to link the fermentation of the electron donor soybean oil to the sequential dechlorination of trichloroethene (TCE) while considering redox conditions and the heterogeneous clay till system (clay till matrix, fractures and sand stringers). The model is tested on lab batch experiments and applied to describe sediment core samples from a TCE-contaminated site. Model simulations compare favorably to field observations and demonstrate that dechlorination may be limited to narrow bioactive zones in the clay matrix around fractures and sand stringers. Field scale simulations show that the injected donor is expected to be depleted after 5 years, and that without donor re-injection contaminant rebound will occur in the high permeability zones and the mass removal will stall at 18%. Long remediation timeframes, if dechlorination is limited to narrow bioactive zones, and the need for additional donor injections to maintain dechlorination activity may limit the efficiency of ERD in low-permeability media. Future work should address the dynamics of the bioactive zones, which is essential to understand for predictions of long term mass removal.

  9. Predictions of first passage times in sparse discrete fracture networks using graph-based reductions

    Science.gov (United States)

    Hyman, J.; Hagberg, A.; Srinivasan, G.; Mohd-Yusof, J.; Viswanathan, H. S.

    2017-12-01

    We present a graph-based methodology to reduce the computational cost of obtaining first passage times through sparse fracture networks. We derive graph representations of generic three-dimensional discrete fracture networks (DFNs) using the DFN topology and flow boundary conditions. Subgraphs corresponding to the union of the k shortest paths between the inflow and outflow boundaries are identified and transport on their equivalent subnetworks is compared to transport through the full network. The number of paths included in the subgraphs is based on the scaling behavior of the number of edges in the graph with the number of shortest paths. First passage times through the subnetworks are in good agreement with those obtained in the full network, both for individual realizations and in distribution. Accurate estimates of first passage times are obtained with an order of magnitude reduction of CPU time and mesh size using the proposed method.

  10. The hematoma block: a simple, effective technique for closed reduction of ankle fracture dislocations.

    Science.gov (United States)

    Ross, Adrianne; Catanzariti, Alan R; Mendicino, Robert W

    2011-01-01

    Management of a dislocated ankle fracture can be challenging because of instability of the ankle mortise, a compromised soft tissue envelope, and the potential neurovascular compromise. Every effort should be made to quickly and efficiently relocate the disrupted ankle joint. Within the emergency department setting, narcotics and benzodiazepines can be used to sedate the patient before attempting closed reduction. The combination of narcotics and benzodiazepines provides relief of pain and muscle guarding; however, it conveys a risk of seizure as well as respiratory arrest. An alternative to conscious sedation is the hematoma block, or an intra-articular local anesthetic injection in the ankle joint and the associated fracture hematoma. The hematoma block offers a comparable amount of analgesia to conscious sedation without the additional cardiovascular risk, hospital cost, and procedure time. Copyright © 2011 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Emergency Closed Reduction of a C4/5 Fracture Dislocation with Complete Paraplegia Resulting in Profound Neurologic Recovery

    Directory of Open Access Journals (Sweden)

    Christian W. Müller

    2013-01-01

    Full Text Available Introduction. Cervical spinal cord injuries due to traumatic fractures are associated with persistent neurological deficits. Although clinical evidence is weak, early decompression, defined as <24–72 h, has been frequently proposed. Animal studies show better outcomes after early decompression within one hour or less, which can hardly ever be achieved in clinical practice. Case Presentation. A 37-year-old patient was hospitalized after being hit by a shying horse. After diagnosis of C4/5 fracture dislocation and complete paraplegia, she was intubated and sedated with deep relaxation. Emergency reduction was performed at approximately 120 minutes after trauma. Subsequently, a standard anterior decompression, discectomy, and fusion were carried out. She was then transferred to a specialized rehabilitation hospital. Her neurologic function improved from AIS grade A on admission to grade B postoperatively and grade D after four months of rehabilitation. One year after the accident, she was ambulatory without walking aids and restarted horse riding. Discussion and Conclusion. Rarely in clinical practice, decompression of the spine canal can be performed as early as in this case. This case highlights the potential benefit of utmost early reduction in cervical fracture dislocations with compression of the spinal cord.

  12. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    Science.gov (United States)

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  13. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    Science.gov (United States)

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Effective management of bone fractures with the IlluminOss® photodynamic bone stabilization system: initial clinical experience from the European Union registry

    Directory of Open Access Journals (Sweden)

    Thomas Gausepohl

    2017-02-01

    Full Text Available The IlluminOss® system (IS uses a light-curable polymer contained within an inflatable balloon catheter, forming a patient customized intramedullary implant. A registry was established in Germany and The Netherlands to prospectively collect technical and clinical outcomes in patients treated with IS for fractures of the phalange, metacarpal, radius, ulna, distal radius, fibula, clavicle and/or olecranon. Humeral, femoral, tibial and pelvic fractures were included under compassionate use. Procedural success included successful placement of the device at the target fracture site and achievement of fracture stabilization. Clinical and radiographic assessments were made postoperatively through 12 months. One hundred thirty two patients (149 fractures were enrolled with most fractures (85% resulting from low-energy trauma. Simple fractures predominated (47% followed by complex (23% and wedge (16% fractures. Procedural success was achieved in all patients and no implants required removal or revision. Normal range of motion was realized in 87% of fractures. Radiographically, there was substantial cortical bridging, total dissolution of the fracture line, and complete fracture healing. Across a variety of fracture types, the IS provides a safe and effective approach for rapid healing and functional recovery.

  15. Fluoroscopy-guided reduction and fibular nail fixation to manage unstable ankle fractures in patients with diabetes: a retrospective cohort study.

    Science.gov (United States)

    Ashman, B D; Kong, C; Wing, K J; Penner, M J; Bugler, K E; White, T O; Younger, A S E

    2016-09-01

    Patients with diabetes are at increased risk of wound complications after open reduction and internal fixation of unstable ankle fractures. A fibular nail avoids large surgical incisions and allows anatomical reduction of the mortise. We retrospectively reviewed the results of fluoroscopy-guided reduction and percutaneous fibular nail fixation for unstable Weber type B or C fractures in 24 adult patients with type 1 or type 2 diabetes. The re-operation rate for wound dehiscence or other indications such as amputation, mortality and functional outcomes was determined. Two patients developed lateral side wound infection, one of whom underwent wound debridement. Three other patients required re-operation for removal of symptomatic hardware. No patient required a below-knee amputation. Six patients died during the study period for unrelated reasons. At a median follow-up of 12 months (7 to 38) the mean Short Form-36 Mental Component Score and Physical Component Score were 53.2 (95% confidence intervals (CI) 48.1 to 58.4) and 39.3 (95% CI 32.1 to 46.4), respectively. The mean Visual Analogue Score for pain was 3.1 (95% 1.4 to 4.9). The mean Ankle Osteoarthritis Scale total score was 32.9 (95% CI 16.0 to 49.7). Fluoroscopy-guided reduction and fibular nail fixation of unstable ankle fractures in patients with diabetes was associated with a low incidence of wound and overall complications, while providing effective surgical fixation. Cite this article: Bone Joint J 2016;98-B:1197-1201. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Study of the X-Ray Diagnosis of Unstable Pelvic Fracture Displacements in Three-Dimensional Space and its Application in Closed Reduction.

    Science.gov (United States)

    Shi, Chengdi; Cai, Leyi; Hu, Wei; Sun, Junying

    2017-09-19

    ABSTRACTS Objective: To study the method of X-ray diagnosis of unstable pelvic fractures displaced in three-dimensional (3D) space and its clinical application in closed reduction. Five models of hemipelvic displacement were made in an adult pelvic specimen. Anteroposterior radiographs of the pelvis were analyzed in PACS. The method of X-ray diagnosis was applied in closed reductions. From February 2012 to June 2016, 23 patients (15 men, 8 women; mean age, 43.4 years) with unstable pelvic fractures were included. All patients were treated by closed reduction and percutaneous cannulate screw fixation of the pelvic ring. According to Tile's classification, the patients were classified into type B1 in 7 cases, B2 in 3, B3 in 3, C1 in 5, C2 in 3, and C3 in 2. The operation time and intraoperative blood loss were recorded. Postoperative images were evaluated by Matta radiographic standards. Five models of displacement were made successfully. The X-ray features of the models were analyzed. For clinical patients, the average operation time was 44.8 min (range, 20-90 min) and the average intraoperative blood loss was 35.7 (range, 20-100) mL. According to the Matta standards, 7 cases were excellent, 12 cases were good, and 4 were fair. The displacements in 3D space of unstable pelvic fractures can be diagnosed rapidly by X-ray analysis to guide closed reduction, with a satisfactory clinical outcome.

  17. Closed reduction and fluoroscopic-assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats.

    Science.gov (United States)

    Boekhout-Ta, Christina L; Kim, Stanley E; Cross, Alan R; Evans, Richard; Pozzi, Antonio

    2017-01-01

    To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. Retrospective study. Client-owned dogs (n = 37) and cats (n = 4). Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classification, preoperative and postoperative displacement), surgical information (implant size, surgical duration), and outcome assessment information (functional outcome, radiographic outcome, and complications). The majority of animals (92%) were classified as full functional outcome. No significant predictors of functional outcome were identified. The overall complication rate was 15% (n = 6). Elective pin removal rate was 41% (n = 17). Goniometry and limb circumference measurements of the affected and contralateral limbs were not significantly different in dogs for which measurements were obtained. Seventeen of 18 animals (16 dogs, 2 cats) measured had bone length changes on follow-up radiographs. FAPP is associated with an excellent functional outcome in a narrow selection of fracture configurations, specifically those with minimal displacement and for which anatomical alignment can be achieved with closed reduction. © 2016 The American College of Veterinary Surgeons.

  18. High-resolution-cone beam tomography analysis of bone microarchitecture in patients with acromegaly and radiological vertebral fractures.

    Science.gov (United States)

    Maffezzoni, Filippo; Maddalo, Michele; Frara, Stefano; Mezzone, Monica; Zorza, Ivan; Baruffaldi, Fabio; Doglietto, Francesco; Mazziotti, Gherardo; Maroldi, Roberto; Giustina, Andrea

    2016-11-01

    Vertebral fractures are an emerging complication of acromegaly but their prediction is still difficult occurring even in patients with normal bone mineral density. In this study we evaluated the ability of high-resolution cone-beam computed tomography to provide information on skeletal abnormalities associated with vertebral fractures in acromegaly. 40 patients (24 females, 16 males; median age 57 years, range 25-72) and 21 healthy volunteers (10 females, 11 males; median age 60 years, range: 25-68) were evaluated for trabecular (bone volume/trabecular volume ratio, mean trabecular separation, and mean trabecular thickness) and cortical (thickness and porosity) parameters at distal radius using a high-resolution cone-beam computed tomography system. All acromegaly patients were evaluated for morphometric vertebral fractures and for mineral bone density by dual-energy X-ray absorptiometry at lumbar spine, total hip, femoral neck, and distal radius. Acromegaly patients with vertebral fractures (15 cases) had significantly (p acromegaly patients did not have significant differences in bone density at either skeletal site. Patients with acromegaly showed lower bone volume/trabecular volume ratio (p = 0.003) and mean trabecular thickness (p acromegaly. High-resolution cone-beam computed tomography at the distal radius may be useful to evaluate and predict the effects of acromegaly on bone microstructure.

  19. Diabetes and change in bone mineral density at the hip, calcaneus, spine, and radius in older women

    Directory of Open Access Journals (Sweden)

    Ann V. Schwartz

    2013-05-01

    Full Text Available Older women with type 2 diabetes mellitus (DM have higher bone mineral density (BMD but also have higher rates of fracture compared to those without DM. Limited evidence suggests that DM may also be associated with more rapid bone loss. To determine if bone loss rates differ by DM status in older women, we analyzed BMD data in the Study of Osteoporotic Fractures (SOF between 1986 and 1998. SOF participants were women >65 years at baseline who were recruited from four regions in the U.S. DM was ascertained by self-report. BMD was measured with dual x-ray absorptiometry (DXA at baseline and at least one follow-up visit at the hip (N=6624 and calcaneus (N=6700 and, on a subset of women, at the spine (N=396 and distal radius (N=306. Annualized percent change in BMD was compared by DM status, using random effects models. Of 6,867 women with at least one follow-up DXA scan, 409 had DM at baseline. Mean age was 70.8 (SD 4.7 years. Baseline BMD was higher in women with DM at all measured sites. In models adjusted for age and clinic, women with prevalent DM lost bone more rapidly than those without DM at the femoral neck (-0.96% vs. -0.59% per year, p < 0.001, total hip (-0.98% vs. -0.70% per year, p<0.001, calcaneus (-1.64% vs. -1.40% per year, p=0.005, and spine (-0.33% vs. +0.33% per year, p=0.033, but not at the distal radius (-0.97% vs. -0.90% per year, p=0.91. These findings suggest that despite higher baseline BMD, older women with DM experience more rapid bone loss than those without DM at the hip, spine and calcaneus, but not the radius. Higher rates of bone loss may partially explain higher fracture rates in older women with DM.

  20. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    ; they will show a sagittally oriented fracture line at the roof of the acetabulum on axial CT. Lastly, wall fractures should be evaluated with axial CT images. This is because wall fractures have an obliquely oriented fracture line on axial CT images at the roof of the acetabulum, as opposed to the coronal and sagittal fracture lines described with column and transverse fractures, respectively.2 Fractures are organized using the Letournel Classification based on whether the fracture site lies in the anterior or posterior walls and columns of bone. After diagnosis, early surgical intervention is critical in achieving good results.3 The majority of acetabular fractures are repaired by open reduction and internal fixation. Patients with significant osteopenia or communition benefit most from total hip arthroplasty. However, due to the complex nature of these fractures, there is potential for poor outcome regardless of the injury pattern due to contributing factors such as imperfect reduction, osteochondral defects in the acetabulum or femoral head, osteoarthritis, avascular necrosis of the femoral head, sciatic nerve injury and infection.4

  1. Influence of the geometry of curved artificial canals on the fracture of rotary nickel-titanium instruments subjected to cyclic fatigue tests.

    Science.gov (United States)

    Lopes, Hélio P; Vieira, Márcia V B; Elias, Carlos N; Gonçalves, Lucio S; Siqueira, José F; Moreira, Edson J L; Vieira, Victor T L; Souza, Letícia C

    2013-05-01

    This study evaluated the influence of different features of canal curvature geometry on the number of cycles to fracture of a rotary nickel-titanium endodontic instrument subjected to a cyclic fatigue test. BioRaCe BR4C instruments (FKG Dentaire, La Chaux-de Fonds, Switzerland) were tested in 4 grooves simulating curved metallic artificial canals, each one measuring 1.5 mm in width, 20 mm in total length, and 3.5 mm in depth with a U-shaped bottom. The parameters of curvature including the radius and arc lengths and the position of the arc differed in the 4 canal designs. Fractured surfaces and helical shafts of the separated instruments were analyzed by scanning electron microscopy. The Student's t test showed that a significantly lower number of cycles to fracture values were observed for instruments tested in canals with the smallest radius, the longest arc, and the arc located in the middle portion of the canal. Scanning electron microscopic analysis of the fracture surfaces revealed morphologic characteristics of ductile fracture. Plastic deformation was not observed in the helical shaft of the fractured instruments. Curvature geometry including the radius and arc lengths and the position of the arc along the root canal influence the number of cycles to fracture of rotary nickel-titanium instruments subjected to flexural load. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.

    Science.gov (United States)

    Langford, Joshua; Pillai, Gita; Ugliailoro, Anthony D; Yang, Edward

    2011-04-01

    This study was performed to determine the incidence of perioperative lateral wall fractures with a standard sliding hip screw (SHS) versus a percutaneous compression plate (PCCP) using identical meticulous closed reduction techniques in both groups. Retrospective analysis of a prospective trauma registry. Urban Level I trauma center. Over a 7-year period, 337 patients with intertrochanteric hip fractures were treated with either a SHS or a PCCP at our institution. The PCCP group (Group 1) consisted of 200 patients, of which 141 (71%) had adequate images to be included in the study. The SHS group (Group 2) consisted of 137 patients, of which 100 (73%) had adequate images to be included in the study. Closed reduction and plate application with either a standard sliding hip screw or a percutaneous compression plate for an Orthopaedic Trauma Association 31A1 or 31A2 intertrochanteric hip fracture. : Radiographic evidence of lateral trochanteric wall fracture as measured by intraoperative and perioperative radiographs. There was an overall lateral wall fracture incidence of 20% in the SHS group versus 1.4% in the PCCP group (P fracture types, there was a lateral wall fracture incidence of 29.8% in the SHS group versus 1.9% in the PCCP group (P trochanteric wall fracture compared with the SHS group. This difference became greater when just unstable intertrochanteric fractures were analyzed. An anatomic reduction, combined with a device (PCCP) that uses small-diameter defects in the lateral trochanteric wall, essentially eliminates perioperative lateral trochanteric wall fractures.

  3. Management of osteoporotic vertebral fractures

    OpenAIRE

    Dionyssiotis, Yannis

    2010-01-01

    Yannis DionyssiotisRhodes General Hospital, Rhodes, GreeceAbstract: Osteoporotic vertebral fractures are associated with considerable reduction of quality of life, morbidity, and mortality. The management of patients with vertebral fractures should include treatment for osteoporosis and measures to reduce pain and improve mobility. This article provides information for management and rehabilitation of vertebral fractures based on clinical experience and literature.Keywords: vertebral fracture...

  4. Treatment of neglected femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Anil K Jain

    2015-01-01

    Full Text Available Intra-capsular femoral neck fractures are seen commonly in elderly people following a low energy trauma. Femoral neck fracture has a devastating effect on the blood supply of the femoral head, which is directly proportional to the severity of trauma and displacement of the fracture. Various authors have described a wide array of options for treatment of neglected/nonunion (NU femoral neck fracture. There is lack of consensus in general, regarding the best option. This Instructional course article is an analysis of available treatment options used for neglected femoral neck fracture in the literature and attempt to suggest treatment guides for neglected femoral neck fracture. We conducted the "Pubmed" search with the keywords "NU femoral neck fracture and/or neglected femoral neck fracture, muscle-pedicle bone graft in femoral neck fracture, fibular graft in femoral neck fracture and valgus osteotomy in femoral neck fracture." A total of 203 print articles were obtained as the search result. Thirty three articles were included in the analysis and were categorized into four subgroups based on treatment options. (a treated by muscle-pedicle bone grafting (MPBG, (b closed/open reduction internal fixation and fibular grafting (c open reduction and internal fixation with valgus osteotomy, (d miscellaneous procedures. The data was pooled from all groups for mean neglect, the type of study (prospective or retrospective, classification used, procedure performed, mean followup available, outcome, complications, and reoperation if any. The outcome of neglected femoral neck fracture depends on the duration of neglect, as the changes occurring in the fracture area and fracture fragments decides the need and type of biological stimulus required for fracture union. In stage I and stage II (Sandhu′s staging neglected femoral neck fracture osteosynthesis with open reduction and bone grafting with MPBG or Valgus Osteotomy achieves fracture union in almost 90

  5. A new method for classifying distal radius fracture: the IDEAL classification Um novo método de classificação para as fraturas da extremidade distal do rádio – a classificação IDEAL

    Directory of Open Access Journals (Sweden)

    João Carlos Belloti

    2013-01-01

    Full Text Available OBJECTIVES: To describe the new IDEAL method from classifying distal radius fractures. METHODS: IDEAL classification system is based on the most important literature evidences about clinical and radiographic characteristics that influence in the treatment and prognosis for patients that suffered from a distal radius fractures. In this method, we classify the fracture in patients first consultation, in which we collect demographical (age and trauma energy and radiographic characteristics ( fracture deviation, articular fracture, and associated lesions. For each feature a score is attributed for grouping purposes. Group I - Stable fractures, good prognosis; Group II - potentially unstable fractures, commonly treated by surgical methods. Prognosis depends on surgeons' success after method choice. Group III - complex and instable fractures, poor outcome is expected. CONCLUSION: IDEAL classification staging rationale was presented, which is based on the best available evidence. The evidence of its scientific plausibility will be settled with the assessment of the classification reliability and its capacity to aid in therapeutical decisions and as a tool to predict prognosis. Further studies are under development to support these properties. OBJETIVOS: Descrição do método de Classificação IDEAL - para as fraturas da extremidade distal do rádio. MÉTODOS: O sistema de classificação IDEAL fundamenta-se nas principais evidências da literatura sobre fatores clínicos e radiográficos que influenciam o tratamento e prognóstico das fraturas do rádio distal. Classificamos as fraturas no atendimento inicial do paciente mediante a verificação de dois dados epidemiológicos e três dados radiográficos: Idade do paciente, energia do trauma, desvio dos fragmentos, incongruência articular e lesões associadas. RESULTADOS: Conforme a pontuação obtida, agrupamos os casos em três grupos: Grupo I - fraturas estáveis com bom prognóstico, Grupo II

  6. Pediatric facial fractures: evolving patterns of treatment.

    Science.gov (United States)

    Posnick, J C; Wells, M; Pron, G E

    1993-08-01

    This study reviews the treatment of facial trauma between October 1986 and December 1990 at a major pediatric referral center. The mechanism of injury, location and pattern of facial fractures, pattern of facial injury, soft tissue injuries, and any associated injuries to other organ systems were recorded, and fracture management and perioperative complications reviewed. The study population consisted of 137 patients who sustained 318 facial fractures. Eighty-one patients (171 fractures) were seen in the acute stage, and 56 patients (147 fractures) were seen for reconstruction of a secondary deformity. Injuries in boys were more prevalent than in girls (63% versus 37%), and the 6- to 12-year cohort made up the largest group (42%). Most fractures resulted from traffic-related accidents (50%), falls (23%), or sports-related injuries (15%). Mandibular (34%) and orbital fractures (23%) predominated; fewer midfacial fractures (7%) were sustained than would be expected in a similar adult population. Three quarters of the patients with acute fractures required operative intervention. Closed reduction techniques with maxillomandibular fixation were frequently chosen for mandibular condyle fractures and open reduction techniques (35%) for other regions of the facial skeleton. When open reduction was indicated, plate-and-screw fixation was the preferred method of stabilization (65%). The long-term effects of the injuries and the treatment given on facial growth remain undetermined. Perioperative complication rates directly related to the surgery were low.

  7. Simulation Of Enhanced Reductive Dechlorination For Remediation Of Tce In A Fractured Clay System: A New Model Approach And Application To Field Site

    DEFF Research Database (Denmark)

    Manoli, Gabriele; Chambon, Julie Claire Claudia; Christiansen, Camilla Maymann

    2010-01-01

    with interspersed sand lenses and stringers. The transport model couples diffusion dominated transport in the clay matrix, with advective‐dispersive transport in the fractures and higher permeability sand lenses. The reactive model calculates sequential reductive dechlorination of TCE (trichloroethylene) to its...... a contamination of trichloroethylene located in a fractured clay till. The site is simulated using the model developed. Fracture geometry, site parameters and degradation rates are based on observations from the site and lab studies. The risk for drinking water is assessed and cleanup times are simulated using...

  8. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  9. Analysis of patterns and treatment strategies for mandibular condyle fractures: review of 175 condyle fractures with review of literature.

    Science.gov (United States)

    Reddy, N Viveka V; Reddy, P Bhaskar; Rajan, Ritesh; Ganti, Srinivas; Jhawar, D K; Potturi, Abhinand; Pradeep

    2013-09-01

    This study aims to evaluate incidence, patterns and epidemiology of mandibular condylar fractures (MCF) to propose a treatment strategy for managing MCF and analyze the factors which influence the outcome. One hundred and seventy-five MCF's were evaluated over a four year period and their pattern was recorded in terms of displacement, level of fracture, age of incidence and dental occlusion. Of the 2,718 facial bone fractures, MCF incidence was the third most common at 18.39 %. Of 175 MCF 58.8 % were unilateral and 41.12 % were bilateral. 67 % of bilateral fractures and 43.8 % of unilateral fractures were associated with midline symphysis and contralateral parasymphysis fractures respectively. Most of the MCF was seen in the age group of above 16 years and 50 % of them were at subcondylar level (below the neck of the condyle). Majority of MCF sustained due to inter personal violence were undisplaced (72.7 %) and contrary to this majority of MCF sustained during road traffic accident were displaced. 62.9 % of total fractures required open reduction and rigid fixation and 37.1 % were managed with closed reduction. 80 % of MCF managed with closed reduction were in the age group of below 16 years. From this study it can be concluded that the treatment algorithm proposed for managing MCF is reliable and easy to adopt. We observed that absolute indication for open reduction of MCF is inability to achieve satisfactory occlusion by closed method and absolute contraindication for open reduction is condylar head fracture irrespective of the age of the patient.

  10. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  11. Simulation-Based Educational Module Improves Intern and Medical Student Performance of Closed Reduction and Percutaneous Pinning of Pediatric Supracondylar Humeral Fractures.

    Science.gov (United States)

    Butler, Bennet A; Lawton, Cort D; Burgess, Jamie; Balderama, Earvin S; Barsness, Katherine A; Sarwark, John F

    2017-12-06

    Simulation-based education has been integrated into many orthopaedic residency programs to augment traditional teaching models. Here we describe the development and implementation of a combined didactic and simulation-based course for teaching medical students and interns how to properly perform a closed reduction and percutaneous pinning of a pediatric supracondylar humeral fracture. Subjects included in the study were either orthopaedic surgery interns or subinterns at our institution. Subjects all completed a combined didactic and simulation-based course on pediatric supracondylar humeral fractures. The first part of this course was an electronic (e)-learning module that the subjects could complete at home in approximately 40 minutes. The second part of the course was a 20-minute simulation-based skills learning session completed in the simulation center. Subject knowledge of closed reduction and percutaneous pinning of supracondylar humeral fractures was tested using a 30-question, multiple-choice, written test. Surgical skills were tested in the operating room or in a simulated operating room. Subject pre-intervention and post-intervention scores were compared to determine if and how much they had improved. A total of 21 subjects were tested. These subjects significantly improved their scores on both the written, multiple-choice test and skills test after completing the combined didactic and simulation module. Prior to the module, intern and subintern multiple-choice test scores were significantly worse than postgraduate year (PGY)-2 to PGY-5 resident scores (p < 0.01); after completion of the module, there was no significant difference in the multiple-choice test scores. After completing the module, there was no significant difference in skills test scores between interns and PGY-2 to PGY-5 residents. Both tests were validated using the scores obtained from PGY-2 to PGY-5 residents. Our combined didactic and simulation course significantly improved intern and

  12. Prior ankle fractures in postmenopausal women are associated with low areal bone mineral density and bone microstructure alterations.

    Science.gov (United States)

    Biver, E; Durosier, C; Chevalley, T; Herrmann, F R; Ferrari, S; Rizzoli, R

    2015-08-01

    In a cross-sectional analysis in postmenopausal women, prior ankle fractures were associated with lower areal bone mineral density (BMD) and trabecular bone alterations compared to no fracture history. Compared to women with forearm fractures, microstructure alterations were of lower magnitude. These data suggest that ankle fractures are another manifestation of bone fragility. Whether ankle fractures represent fragility fractures associated with low areal bone mineral density (aBMD) and volumetric bone mineral density (vBMD) and/or bone microstructure alterations remains unclear, in contrast to the well-recognised association between forearm fractures and osteoporosis. The objective of this study was to investigate aBMD, vBMD and bone microstructure in postmenopausal women with prior ankle fracture in adulthood, compared with women without prior fracture or with women with prior forearm fractures, considered as typically of osteoporotic origin. In a cross-sectional analysis in the Geneva Retirees Cohort study, 63 women with ankle fracture and 59 with forearm fracture were compared to 433 women without fracture (mean age, 65 ± 1 years). aBMD was measured by dual-energy X-ray absorptiometry; distal radius and tibia vBMD and bone microstructure were measured by high-resolution peripheral quantitative computed tomography. Compared with women without fracture, those with ankle fractures had lower aBMD, radius vBMD (-7.9%), trabecular density (-10.7%), number (-7.3%) and thickness (-4.6%) and higher trabecular spacing (+14.5%) (P ankle fractures were 2.2 and 1.6, respectively, vs 2.2 and 2.7 for forearm fracture, respectively (P ≤ 0.001 for all). Compared to women with forearm fractures, those with ankle fractures had similar spine and hip aBMD, but microstructure alterations of lower magnitude. Women with ankle fractures have lower aBMD and vBMD and trabecular bone alterations, suggesting that ankle fractures are another manifestation of bone fragility.

  13. Pulsed electromagnetic field during cast immobilization in postmenopausal women with Colles’ fracture

    Directory of Open Access Journals (Sweden)

    Lazović Milica

    2012-01-01

    Full Text Available Introduction. Although Colles’ fracture i.e. a dorsally displaced distal radius fracture (DRF is one of the most common fractures, there is no enough evidence to determine the best form of rehabilitation. Objective. To assess whether the use of pulsed electromagnetic field (PEMF therapy during cast immobilization of DRF provides beneficial effects on pain, edema, wrist range of motion and function, as well as on the frequency of complications immediately after cast removal. Methods. The prospective randomized controlled study included 60 women over the age of 55 years with extra-articular displaced DRF treated with reduction and cast immobilization. The patients were alternately allocated to either a PEMF group (n=30, received 10 days of PEMF therapy during immobilization, or a control group (n=30, without PEMF therapy. Pain, function, hand circumference, wrist and forearm range of motion and frequency of complications for each patient was evaluated within two to three days of cast removal. Results. Better mean values for the majority of examined parameters were recorded in the PEMF group than in the control group, but the difference was statistically significant just for edema (p<0.001, flexion, extension and supination range (p<0.01. Conclusion. During immobilization PEMF therapy in DRF patients gave better results immediately after cast removal in terms of edema and wrist range of motion (ROM.

  14. High strength, biodegradable and cytocompatible alpha tricalcium phosphate-iron composites for temporal reduction of bone fractures.

    Science.gov (United States)

    Montufar, E B; Casas-Luna, M; Horynová, M; Tkachenko, S; Fohlerová, Z; Diaz-de-la-Torre, S; Dvořák, K; Čelko, L; Kaiser, J

    2018-04-01

    In this work alpha tricalcium phosphate (α-TCP)/iron (Fe) composites were developed as a new family of biodegradable, load-bearing and cytocompatible materials. The composites with composition from pure ceramic to pure metallic samples were consolidated by pulsed electric current assisted sintering to minimise processing time and temperature while improving their mechanical performance. The mechanical strength of the composites was increased and controlled with the Fe content, passing from brittle to ductile failure. In particular, the addition of 25 vol% of Fe produced a ceramic matrix composite with elastic modulus much closer to cortical bone than that of titanium or biodegradable magnesium alloys and specific compressive strength above that of stainless steel, chromium-cobalt alloys and pure titanium, currently used in clinic for internal fracture fixation. All the composites studied exhibited higher degradation rate than their individual components, presenting values around 200 μm/year, but also their compressive strength did not show a significant reduction in the period required for bone fracture consolidation. Composites showed preferential degradation of α-TCP areas rather than β-TCP areas, suggesting that α-TCP can produce composites with higher degradation rate. The composites were cytocompatible both in indirect and direct contact with bone cells. Osteoblast-like cells attached and spread on the surface of the composites, presenting proliferation rate similar to cells on tissue culture-grade polystyrene and they showed alkaline phosphatase activity. Therefore, this new family of composites is a potential alternative to produce implants for temporal reduction of bone fractures. Biodegradable alpha-tricalcium phosphate/iron (α-TCP/Fe) composites are promising candidates for the fabrication of temporal osteosynthesis devices. Similar to biodegradable metals, these composites can avoid implant removal after bone fracture healing, particularly in

  15. Late leaflet fracture and embolization of a Duromedics mitral prosthesis.

    Science.gov (United States)

    Sudo, K; Sasagawa, N; Ide, H; Nunokawa, M; Fujiki, T; Tonari, K

    2000-08-01

    A case of leaflet fracture and embolization of a mitral prosthetic valve is described. A 54-year-old man had received mitral valve replacement with an Edwards-Duromedics 29M prosthetic valve, at 10 years ago. Emergency mitral valve replacement was performed because the patient had severe congestive left heart failure with severe acute mitral regurgitation caused by a fracture in one of the mitral valve leaflets. The leaflet, which was fractured into 2 pieces, was removed from the right common iliac artery at 3 months after valve replacement. Visual inspection revealed that the leaflet contained a midline fracture. The fracture originated within a cavitary erosion pit near the major radius of the leaflet. The patient recovered from acute renal failure, requiring hemodialysis for 80 days, and is currently without complaints. We have used a Duromedics mitral valve in 11 patients, from April 1987 to April 1988. No subsequent valve failure has occurred. The diagnosis, treatment and cause of a mechanical valve fracture are discussed.

  16. Antero-medial approach to the wrist: anatomic basis and new application in cases of fracture of the lunate facet.

    Science.gov (United States)

    Uzel, A-P; Bulla, A; Laurent-Joye, M; Caix, P

    2011-08-01

    The Henry approach is the classical anterolateral surgical exposure of the volar aspect of the distal radius. This approach does not allow good access to the medial side of the volar distal radius (lunate facet) and the distal radio-ulnar joint, unless it is extended proximally, retracting the tendons and the median nerve medially, which can cause some trauma. The purpose of our study was to investigate the anatomic basis and to outline the advantages of the unusual anteromedial approach, reporting our experience in the treatment of 4 distal radius fractures, with a 90° or 180° twist of the lunate facet, and 10 wrist dissections on cadavers. The average follow-up was 68.8 months (range 18 to 115 months). In our series, this approach did not cause any nerve injuries or any sensory loss of the distal forearm and the palm. All the fractures of the lunate facet and of the radial styloid process healed. One patient with an ulnar styloid process fracture associated showed pseudarthrosis, but with no instability of the distal radio-ulnar joint or pain on the ulnar side. Using the criteria of Green and O'Brien, modified by Cooney, the results were: excellent in two cases, good in one case, and average in another. The evaluation of arthritis according to Knirk and Jupiter's classification showed grade 0 in three cases and grade 3 in one case with osteochondral sclerosis. We showed that the anteromedial approach is reliable and convenient in the case of fractures situated in the antero-medial portion of the radius, for the double objective of reducing the fracture under direct control and checking the congruence of the distal radio-ulnar joint.

  17. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  18. Complex tibial plateau fractures treated by hybrid external fixation system: A correlation of followup computed tomography derived quality of reduction with clinical results

    Directory of Open Access Journals (Sweden)

    Konstantinos Kateros

    2018-01-01

    Full Text Available Background: Tibial plateau fractures are common due to high energy injuries. The principles of treatment include respect for the soft tissues, restoring the congruity of the articular surface and reduction of the anatomic alignment of the lower limb to enable early movement of the knee joint. There are various surgical fixation methods that can achieve these principles of treatment. Recognition of the particular fracture pattern is important, as this guides the surgical approach required in order to adequately stabilize the fracture. This study evaluates the results of the combined treatment of external fixator and limited internal fixation along with the advantages using postoperative computed tomography (CT scan after implant removal. Materials and Methods: 55 patients with a mean age of 42 years (range 17–65 years with tibial plateau fracture, were managed in our institution between October 2010 and September 2013., Twenty fractures were classified as Schatzker VI and 35 as Schatzker V. There were 8 open fractures (2 Gustilo Anderson 3A and 6 Gustilo Anderson 2. All fractures were treated with closed reduction and hybrid external fixation (n = 21/38.2% or with minimal open reduction internal fixation and a hybrid system (n = 34/61.8%. After the removal of the fixators, CT-scan was programmed for all the cases, for correlation with the results. At final followup, the American Knee Society Score (AKSS was administered. Results: All patients were evaluated with a minimum of 12 months (range 12–21 months followup. Average time to union was 15.5 weeks (range 13–19 weeks. The postoperative joint congruity as evaluated in the postoperative CT-scan was 5° in 19 cases (35%. Patients with residual joint depression 4.5 mm displayed a 100% chance of getting poor-fair scores both in AKSS knee and AKSS function score. The association of a postoperative mechanical axis within 5° of the contralateral limb and improved knee scores was statistically

  19. Pain reduction after percutaneous vertebroplasty for myeloma-associated vertebral fractures

    DEFF Research Database (Denmark)

    Simony, Ane; Hansen, Emil Jesper; Gaurilcikas, Marius

    2014-01-01

    INTRODUCTION: Percutaneous vertebroplasty (PVP) is a minimally invasive procedure with cement augmentation of vertebral fractures. It was introduced in 1987 as a treatment for painful haemangiomas and is today mostly used for painful osteoporotic fractures of the spine. Two randomised, double...

  20. Injuries of the scapholunate and lunotriquetral ligaments as well as the TFCC in intra-articular distal radius fractures. Prevalence assessed with MDCT arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Klempka, A.; Wagner, M.; Fodor, S.; Schmitt, R. [Cardiovascular Center Bad Neustadt an der Saale, Department of Diagnostic and Interventional Radiology, Bad Neustadt an der Saale (Germany); Prommersberger, K.J. [Clinic for Hand Surgery, Bad Neustadt an der Saale (Germany); Uder, M. [Friedrich-Alexander-University Erlangen-Nuernberg (FAU), Department of Diagnostic Radiology, Erlangen (Germany)

    2016-03-15

    To evaluate the prevalence of injuries of the scapholunate and lunotriquetral interosseous ligaments (SLIL, LTIL) as well as the triangular fibrocartilage complex (TFCC) in intra-articular distal radius fractures (iaDRF). Two hundred and thirty-three patients with acute iaDRF underwent MDCT arthrography. The SLIL and LTIL were described as normal, partially or completely ruptured. Major injuries of the SLIL were defined as completely ruptured dorsal segments, those of the LTIL as completely ruptured palmar segments. The TFCC was judged as normal or injured. Interobserver variability was calculated. Injury findings were correlated with the types of iaDRF (AO classification). In 159 patients (68.2 %), no SLIL injuries were seen. Minor SLIL injuries were detected in 54 patients (23.2 %), major injuries in 20 patients (8.6 %). No correlation was found between the presence of SLIL lesions and the types of iaDRF. Minor LTIL injuries were seen in 23 patients (9.9 %), major injuries in only 5 patients (2.2 %). The TFCC was altered in 141 patients (60.5 %). Interobserver variability was high for MDCT arthrography in assessing SLIL and TFC lesions, and fair for LTIL lesions. In iaDRF, prevalence of major injuries of the most relevant SLIL is about 9 % as evaluated with CT arthrography. (orig.)

  1. The effect of electric discharge machined notches on the fracture toughness of several structural alloys

    International Nuclear Information System (INIS)

    Joyce, J.A.; Link, R.E.

    1993-09-01

    Recent computational studies of the stress and strain fields at the tip of very sharp notches have shown that the stress and strain fields are very weakly dependent on the initial geometry of the notch once the notch has been blunted to a radius that is 6 to 10 times the initial root radius. It follows that if the fracture toughness of a material is sufficiently high so that fracture initiation does not occur in a specimen until the crack-tip opening displacement (CTOD) reaches a value from 6 to 10 times the size of the initial notch tip diameter, then the fracture toughness will be independent of whether a fatigue crack or a machined notch served as the initial crack. In this experimental program the fracture toughness (J Ic and J resistance (J-R) curve, and CTOD) for several structure alloys was measured using specimens with conventional fatigue cracks and with EDM machined notches. The results of this program have shown, in fact, that most structural materials do not achieve initiation CTOD values on the order of 6 to 10 times the radius of even the smallest EDM notch tip presently achievable. It is found furthermore that tougher materials do not seem to be less dependent on the type of notch tip present. Some materials are shown to be much more dependent on the type of notch tip used, but no simple pattern is found that relates this observed dependence to the material strength toughness, or strain hardening rate

  2. early operative management of pilon fractures using the ...

    African Journals Online (AJOL)

    Background: Pilon fractures is a management challenge due to complexity of fracture pattern and ... excellent exposure for accurate fracture reduction and no wound complications in our case ... dehiscence, superficial infection, osteomyelitis,.

  3. A trans-ethnic genome-wide association study identifies gender-specific loci influencing pediatric aBMD and BMC at the distal radius.

    Science.gov (United States)

    Chesi, Alessandra; Mitchell, Jonathan A; Kalkwarf, Heidi J; Bradfield, Jonathan P; Lappe, Joan M; McCormack, Shana E; Gilsanz, Vicente; Oberfield, Sharon E; Hakonarson, Hakon; Shepherd, John A; Kelly, Andrea; Zemel, Babette S; Grant, Struan F A

    2015-09-01

    Childhood fractures are common, with the forearm being the most common site. Genome-wide association studies (GWAS) have identified more than 60 loci associated with bone mineral density (BMD) in adults but less is known about genetic influences specific to bone in childhood. To identify novel genetic factors that influence pediatric bone strength at a common site for childhood fractures, we performed a sex-stratified trans-ethnic genome-wide association study of areal BMD (aBMD) and bone mineral content (BMC) Z-scores measured by dual energy X-ray absorptiometry at the one-third distal radius, in a cohort of 1399 children without clinical abnormalities in bone health. We tested signals with P BMC-Z). Signals at the CPED1-WNT16-FAM3C locus have been previously associated with BMD at other skeletal sites in adults and children. Our result at the distal radius underscores the importance of this locus at multiple skeletal sites. The 9p21.3 locus is within a gene desert, with the nearest gene flanking each side being MIR31HG and MTAP, neither of which has been implicated in BMD or BMC previously. These findings suggest that genetic determinants of childhood bone accretion at the radius, a skeletal site that is primarily cortical bone, exist and also differ by sex. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Compound dorsal dislocation of lunate with trapezoid fracture

    Directory of Open Access Journals (Sweden)

    Bong-Sung Kim

    2016-12-01

    Full Text Available We report about a dorsal dislocation of the lunate accompanied by a trapezoid fracture in a 41-year old male patient after a motorcycle accident. The lunate dislocation with no dorsal or volar intercalated segment instability (DISI, VISI was diagnosed by x-ray whereas the trapezoid fracture was only diagnosable by computed tomography. A closed reduction and internal fixation of the lunate by two Kirschner wires was performed, the trapezoid fracture was conservatively treated. Surgery was followed by immobilization, intense physiotherapy and close follow-up. Even though complaints such as swelling and pain subsided during the course of rehabilitation, partial loss of strength and range of motion remained even after 16 months. In conclusion, a conservative treatment of trapezoid fractures seems to be sufficient in most cases. Closed reduction with Kwire fixation led to an overall satisfactory result in our case. For dorsal lunate dislocations in general, open reduction should be performed when close reduction is unsuccessful or DISI/VISI are observed in radiographs after attempted close reduction.

  5. Overview of Mandibular Condyle Fracture

    Directory of Open Access Journals (Sweden)

    Su-Seong Park

    2012-07-01

    Full Text Available The mandibular condyle is a region that plays a key role in the opening and closing ofthe mouth, and because fracture causes functional and aesthetic problems such as facialasymmetry, it is very important to perform accurate reduction. Traditionally, there has beendisagreement on how to manage fracture of the mandibular condyle. This review exploresthe misunderstanding of mandibular condyle fracture treatment and modern-day treatmentstrategies.

  6. A novel closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation for mallet fractures.

    Science.gov (United States)

    Shimura, Haruhiko; Wakabayashi, Yoshiaki; Nimura, Akimoto

    2014-03-01

    Some patients with mallet fractures who undergo extension block pinning complain of exposed wires, which delay their return to sports and causes inconvenience while performing tasks that require the use of hands during the early postoperative period. The purpose of this retrospective study was to present and evaluate a novel surgical procedure for mallet fractures. We treated 20 patients (14 males and six females; mean age, 38.4 years; range 17-68 years) with displaced mallet fractures involving >30 % of the articular surface using the closed reduction and microscrew fixation between January 2009 and January 2012. The distal interphalangeal joint (DIP) joint was immobilized with a splint for 1-3 weeks on an individual case basis. According to Wehbe and Schneider's classification, there were 12 type IB, six type IIB, and two type IA fractures. The mean follow-up duration was 12.6 months (range 6-31 months). Bone union was achieved in all patients within a mean period of 6.8 weeks, with no incidence of infection, skin necrosis, permanent nail deformity, or secondary osteoarthritis. Only two complications-temporary nail ridging in one patient and a dorsal bump caused by the screw in one patient-were observed. Minimum postoperative displacement was observed in one patient, for whom immobilization with a splint was continued for 4 weeks. Articular incongruity was <1.0 mm in four patients and 1.0-2.0 mm in two patients. Mean DIP joint extension loss was 6.5° and mean flexion was 67.8°. The surgical outcomes were excellent in seven patients, good in nine, and fair in four according to Crawford's evaluation criteria. Our novel surgical procedure combining closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation produces good clinical results with relatively few complications.

  7. [Intramedullary osteosynthesis of distal metacarpal fractures with curved wires].

    Science.gov (United States)

    Schlageter, M; Winkel, R; Porcher, R; Haas, H G

    1997-07-01

    When intramedullary pinning is used to treat metacarpal fractures, as recently described by Förstner (1994) and Foucher (1995), the closed reduction technique developed by Jahss (1938) is applied in the same way as for conservative fracture treatment. It is not always possible to achieve complete anatomical reduction using this closed technique. The intramedullary pinning technique, that we have applied since 1989, involves a Kirschner wire which is bent at one end. Apart from reducing the fracture, the pre-set Kirschner wire serves as a butressing internal fixator. The elastic clamping of the wire acts as an internal wire spring splint, permitting early mobilisation. We have operated on 62 metacarpal fractures using the above-mentioned technique over a period of 6 years until 1995. Anatomic reduction was realized in 50 of 62 fractures. In the follow-up of 32 fractures, we noticed four complications: one infection, two paraesthesias, and one non-union.

  8. OC30 - Fracture reduction with nitrous oxide at the children's emergency department shortens the length of stay and reduces the use of full anaesthesia in the operating department.

    Science.gov (United States)

    Lang, Sigrid; Wentzel, Anna-Pia; Ekstrom, Malin

    2016-05-09

    Theme: Accreditation and quality improvement. Dislocated fractures are common in the children's emergency department (ER). All forms of fracture reduction are very painful requiring nitrous oxide. The purpose is to shorten the length of stay in the hospital as well as sustain a high quality of care. All nurses received theoretical and practical training in the use of nitrous oxide. Evaluations with the families were made by telephone. A total of 40 enclosed fracture reductions were made at the ER, leading to a reduction of 33 patients in the operating department and the length of stay was shortened - this compared to the same time in 2014. No adverse event was reported and no patient felt any increase in pain during the treatment. All patients would repeat the procedure if necessary. The treatment has reduced the length of stay in the hospital without affecting the other patients in the ER or the quality of care.

  9. A position statement of the Traumatology Society of Slovenia on the treatment of fragility fractures of the pelvic ring

    Directory of Open Access Journals (Sweden)

    Drago Brilej

    2016-11-01

    Full Text Available Because of the ageing crisis in western world the fragility fractures of the pelvic ring joint the big four group of typical fractures in osteoporotic elderly patients: fractures of the proximal femur, fractures of the proximal humerus, fractures of the distal radius and thoracic and lumbar low energy spinal fractures. All these fractures are the result of low energy with the typical fall of the patient from the standing height. The Slovenian recommendations include Rommens classification for non-displaced and displaced fractures of the anterial and posterial pelvic ring with the operative indications. The recommendations were launched at the Slovenian society of trauma surgeons meeting in November 7th, 2015.

  10. Tibial Plateau Fractures

    DEFF Research Database (Denmark)

    Elsøe, Rasmus

    This PhD thesis reported an incidence of tibial plateau fractures of 10.3/100,000/year in a complete Danish regional population. The results reported that patients treated for a lateral tibial plateau fracture with bone tamp reduction and percutaneous screw fixation achieved a satisfactory level...... with only the subgroup Sport significantly below the age matched reference population. The thesis reports a level of health related quality of life (Eq5d) and disability (KOOS) significantly below established reference populations for patients with bicondylar tibial plateau fracture treated with a ring...... fixator, both during treatment and at 19 months following injury. In general, the thesis demonstrates that the treatment of tibial plateau fractures are challenging and that some disabilities following these fractures must be expected. Moreover, the need for further research in the area, both with regard...

  11. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    Science.gov (United States)

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  12. C-arm guided closed reduction of zygomatic arch fracture

    International Nuclear Information System (INIS)

    Eo, Yoon Ki; Lee, Dong Kun; Kim, Jeong Sam; Jang, Young Il

    1999-01-01

    The zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Alling and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients

  13. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].

    Science.gov (United States)

    Zeman, P; Zeman, J; Matejka, J; Koudela, K

    2008-12-01

    To report on the surgical treatment of intra-articular calcaneal fractures by open reduction and internal fixation with a calcaneal locking compression plate (LCP) from an extended lateral approach, and to retrospectively analyze the mid-term results in a group of patients treated by this technique. In the period from August 2005 till March 2007, a total of 49 patients with 61 calcaneal fractures were treated. Of these, 11 (18 %) were treated conservatively. Reduction combined with Kirschner-wire fixation was used in four fractures (6.6 %). Open reduction with internal calcaneal LCP fixation (ORIF- calcaneal LCP) from an extended lateral approach was carried out to treat 46 fractures (75.4 %) in 38 patients. The group evaluated here comprised 29 patients with 33 calcaneal fractures treated by ORIF-calcaneal LCP at a follow-up longer than 6 months. The fractures were classified on the basis of computer tomography (CT) findings as Sanders types I to IV. The group had two woman (6.9 %) and 27 men (93.1 %) with an average age of 34.2 years (range, 19-55 years). In 11 fractures (33.3 %), the primary treatment included filling a central cancellous bone defect area. Calcium phosphate bone substitute material (resorbable ChronOS) was used in nine cases (27.3 %), a self-solidifying hydroxyapatite implant was injected in two (6.1 %) cases (X3 Wright and Norian SRS, respectively), and a bone allograft was implanted in one case (3 %). Indicated for surgery were patients with an intra-articular calcaneal fracture, Sanders type II or type III, with articular surface displacement by more than 1 mm. Contraindications included age over sixty years, poor cooperation, smoking habits, peripheral vascular disease or skin infection. Surgery was performed only after oedema had resolved. The aim of our treatment was to achieve anatomical reconstruction of all articular surfaces, to restore the height, length, width and axis of the heel bone, to carry out primary stable osteosynthesis, and

  14. Ever-changing proton radius?

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovic, Miha [Institut fuer Kernphysik, Johannes-Gutenberg-Universitaet, Mainz (Germany)

    2016-07-01

    The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the presently best value obtained from elastic scattering experiments remains unexplained and represents a burning problem of today's nuclear physics. Therefore, several new experiments are underway, committed to provide new insight into the problem. High-precision electron scattering experiments are in progress at the Jefferson Lab and the Mainz Microtron. As a counterpart to these measurements, a muon-proton scattering experiment is envisioned at the Paul Scherrer Institute. Together with the nuclear scattering experiments, new atomic measurements are underway at the Max Planck Institute in Garching, which aim to further improve also the spectroscopic results on electronic hydrogen. These experiments are complemented by extensive theoretical efforts focused on studying various processes contributing to the atomic Lamb shift measurements that could explain the difference, as well as on pursuing different ways to interpret nuclear form-factor measurements, which could lead to a consistent value of the radius. In this presentation the currently best proton radius measurements are summarized, and the importance of the observed inconsistency between the hydrogen and the muonic-hydrogen data is discussed. Selected new experiments dedicated to remeasuring the radius are described, and the results of the MAMI experiment are presented.

  15. Puzzling out the proton radius puzzle

    Directory of Open Access Journals (Sweden)

    Mihovilovič Miha

    2014-01-01

    Full Text Available The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the best present value obtained from the elastic scattering experiments, remains unexplained and represents a burning problem of today’s nuclear physics: after more than 50 years of research the radius of a basic constituent of matter is still not understood. This paper presents a summary of the best existing proton radius measurements, followed by an overview of the possible explanations for the observed inconsistency between the hydrogen and the muonic-hydrogen data. In the last part the upcoming experiments, dedicated to remeasuring the proton radius, are described.

  16. Puzzling out the proton radius puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovič, M.; Merkel, H.; Weber, A. [Institut für Kernphysik, Johannes Gutenberg-Universität Mainz, Johann-Joachim-Becher-Weg 45, 55128 Mainz (Germany)

    2016-01-22

    The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the best present value obtained from the elastic scattering experiments, remains unexplained and represents a burning problem of today’s nuclear physics: after more than 50 years of research the radius of a basic constituent of matter is still not understood. This paper presents a summary of the best existing proton radius measurements, followed by an overview of the possible explanations for the observed inconsistency between the hydrogen and the muonic-hydrogen data. In the last part the upcoming experiments, dedicated to remeasuring the proton radius, are described.

  17. Nuclear charge radius of $^{12}$Be

    CERN Document Server

    Krieger, Andreas; Bissell, Mark L; Frömmgen, Nadja; Geppert, Christopher; Hammen, Michael; Kreim, Kim; Kowalska, Magdalena; Krämer, Jörg; Neff, Thomas; Neugart, Rainer; Neyens, Gerda; Nörtershäuser, Wilfried; Novotny, Christian; Sanchez, Rodolfo; Yordanov, Deyan T

    2012-01-01

    The nuclear charge radius of $^{12}$Be was precisely determined using the technique of collinear laser spectroscopy on the $2s_{1/2}\\rightarrow 2p_{1/2, 3/2}$ transition in the Be$^{+}$ ion. The mean square charge radius increases from $^{10}$Be to $^{12}$Be by $\\delta ^{10,12} = 0.69(5)$ fm$^{2}$ compared to $\\delta ^{10,11} = 0.49(5)$ fm$^{2}$ for the one-neutron halo isotope $^{11}$Be. Calculations in the fermionic molecular dynamics approach show a strong sensitivity of the charge radius to the structure of $^{12}$Be. The experimental charge radius is consistent with a breakdown of the N=8 shell closure.

  18. Overview of Mandibular Condyle Fracture

    OpenAIRE

    Park, Su-Seong; Lee, Keun-Cheol; Kim, Seok-Kwun

    2012-01-01

    The mandibular condyle is a region that plays a key role in the opening and closing of the mouth, and because fracture causes functional and aesthetic problems such as facial asymmetry, it is very important to perform accurate reduction. Traditionally, there has been disagreement on how to manage fracture of the mandibular condyle. This review explores the misunderstanding of mandibular condyle fracture treatment and modern-day treatment strategies.

  19. Overview of Mandibular Condyle Fracture

    Directory of Open Access Journals (Sweden)

    Su-Seong Park

    2012-07-01

    Full Text Available The mandibular condyle is a region that plays a key role in the opening and closing of the mouth, and because fracture causes functional and aesthetic problems such as facial asymmetry, it is very important to perform accurate reduction. Traditionally, there has been disagreement on how to manage fracture of the mandibular condyle. This review explores the misunderstanding of mandibular condyle fracture treatment and modern-day treatment strategies.

  20. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. The application of the Risdon approach for mandibular condyle fractures.

    Science.gov (United States)

    Nam, Seung Min; Lee, Jang Hyun; Kim, Jun Hyuk

    2013-07-06

    Many novel approaches to mandibular condyle fracture have been reported, but there is a relative lack of reports on the Risdon approach. In this study, the feasibility of the Risdon approach for condylar neck and subcondylar fractures of the mandible is demonstrated. A review of patients with mandibular condylar neck and subcondylar fractures was performed from March 2008 to June 2012. A total of 25 patients, 19 males and 6 females, had 14 condylar neck fractures and 11 subcondylar fractures. All of the cases were reduced using the Risdon approach. For subcondylar fractures, reduction and fixation with plates was done under direct vision. For condylar neck fractures, reduction and fixation was done with the aid of a trochar in adults and a percutaneous threaded Kirschner wire in children. There were no malunions or nonunions revealed in follow-up care. Mild transient neuropraxia of the marginal mandibular nerve was seen in 4 patients, which was resolved within 1-2 months. The Risdon approach is a technique for reducing the condylar neck and subcondylar fractures that is easy to perform and easy to learn. Its value in the reduction of mandibular condyle fractures should be emphasized.

  2. Propagation of fractures from an interface in a Brazilian test specimen

    CSIR Research Space (South Africa)

    Malan, DF

    1994-12-01

    Full Text Available by Berenbaum and Brodie \\[4\\]. If a circular disc of radius R and unit thickness is compressed across a diameter by line loads W as shown in Fig. 2(a), the stresses on this diameter are given by Jaeger and Cook \\[5\\] as W ~' ~R (1) - W(3R z + x 2) a.... SIMULATION OF FRACTURE GROWTH Numerical simulation of fracture growth using small- strain dislocation theory has been reported by a number of workers, for example Cornet \\[11\\], Sun et al. \\[12\\] and Thomas and Pollard \\[13\\]. The technique used...

  3. Rehabilitation after falls and fractures.

    Science.gov (United States)

    Dionyssiotis, Y; Dontas, I A; Economopoulos, D; Lyritis, G P

    2008-01-01

    Falls are one of the most common geriatric problems threatening the independence of older persons. Elderly patients tend to fall more often and have a greater tendency to fracture their bones. Fractures occur particularly in osteoporotic people due to increased bone fragility, resulting in considerable reduction of quality of life, morbidity, and mortality. This article provides information for the rehabilitation of osteoporotic fractures pertaining to the rehabilitation of the fractured patient, based on personal experience and literature. It also outlines a suggested effective and efficient clinical strategy approach for preventing falls in individual patients.

  4. [Calcaneal fractures treated by open reduction and internal fixation with a locking compression plate (LCP). A prospective study. part I: basic analysis of the group].

    Science.gov (United States)

    Svatoš, F; Bartoška, R; Skála-Rosenbaum, J; Douša, P; Pacovský, V; Krbec, M

    2011-01-01

    In a prospective study of patients with calcaneal fractures treated by open reduction from an extensile lateral approach and LCP osteosynthesis, the authors evaluated the basic epidemiological data, mechanism of injury, type of fracture, essential data on surgery, days of hospital stay and the number of complications. In the period from September 1, 2006 to July 31, 2010, a total of 230 patients with 243 calcaneal fractures were treated. The fractures were classified as either open or closed and according to the Essex-Lopresti system. Of the total number of patients, 135 (55.6 % of all fractures) were indicated for conservative treatment and 108 (44.4% of all fractures) for surgical intervention. Indications for surgery based on the generally accepted criteria enabled us to select 77 patients with 82 fractures (33.7 % of all fractures) for treatment by the method of open reduction and LCP osteosynthesis. These patients constituted the group evaluated here. The other patients were treated using other techniques (21 fractures, i.e., 8.6 % of all fractures, by the Stehlík-Štulík transfixation method and further five [2.1 %] by screw osteosynthesis). Six surgeons were involved in the treatment of this group. For the diagnosis of fractures, plain radiographs in lateral and axial projection and axial and coronal CT images were used. All fractures were treated after subsidence of oedema by the method of open reduction and LCP fixation from an extensile lateral approach, with the use of a tourniquet. The follow-up period for the evaluation of functional outcome and bone union was 3 to 48 months. Fifty patients were followed up for over one year. The group evaluated comprised 58 men (75.3 %) with 63 fractures (76.8 %) and 19 women (24.7 %) with 19 fractures (23.2 %). The average age of the group was 42 years, with 41 years (range, 22-61 years) in men and 47 years (range, 30-70 years) in women. The most frequent cause of injury was a fall from a height below 1 metre and

  5. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  6. CURBSIDE CONSULTATION IN FRACTURE MANAGEMENT: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Walter W. Virkus

    2008-12-01

    Full Text Available DESCRIPTION: A user-friendly, unique resource for the treatment of fractures designed in a casual questions and answers format which provides basic knowledge, current information and evidence based expert advices enhanced by images and diagrams and supported by ref-erences.PURPOSE: Designing this book the editor has aimed to prepare not only a source of current knowledge and opin-ions by experienced authors in fracture management for decision making in daily practice but also a brief refer-ence and useful educational resource in orthopedic trauma surgery.FEATURES: Three Sections are composed of 49 sub-jects in a form of the answers of frequently asked ques-tions richly illustrated by images and diagrams and in-cluding references at the end of each subject.The Section I is “UPPER EXTREMITIES” including: Neck fracture; Humerus shaft fracture; Management of radial nerve palsy associated with humeral fracture; Clavicle fractures; Elbow fractures in children; Fasciot-omy technic of the forearm; Distal radius fracture; Indica-tions of radial head replacement, Femur and humeral shaft fractures; Treatment of posterolateral elbow dislocation; The Section II is “LOWER EXTREMITIES” including : Femur fractures; Pelvic fractures; Life threatening pelvic fractures; Decision for surgical treatment in pelvic frac-tures; Treatment of anterior fracture of femoral head and hip joint incongruity; Management of a displaced femoral neck fracture in young patient in ER; Elder patients with displaced femoral head fracture; Patella and tibial plateau fractures; Criteria for compartment syndromes in the tibia; Tricks in nailing proximal and distal tibial fractures; Surgical management of distal tibia spiral fracture in middle aged women; Pilon fracture; Management of syn-desmotic screws in adult patient; The management of minimally displaced posterior malleol in three malleolar fractures; Postoperative management of bimalleolar frac-tures; Management of minimally

  7. Role of Ankle Arthroscopy in Management of Acute Ankle Fracture.

    Science.gov (United States)

    Chan, Kwok Bill; Lui, Tun Hing

    2016-11-01

    To report the operative findings of ankle arthroscopy during open reduction and internal fixation of acute ankle fractures. This was a retrospective review of 254 consecutive patients with acute ankle fractures who were treated with open reduction and internal fixation of the fractures, and ankle arthroscopy was performed at the same time. The accuracy of fracture reduction, the presence of syndesmosis disruption and its reduction, and the presence of ligamentous injuries and osteochondral lesions were documented. Second-look ankle arthroscopy was performed during syndesmosis screw removal 6 weeks after the key operation. There were 6 patients with Weber A, 177 patients with Weber B, 51 patients with Weber C, and 20 patients with isolated medial malleolar fractures. Syndesmosis disruption was present in 0% of patients with Weber A fracture, 52% of patients with Weber B fracture, 92% of patients with Weber C fracture, and 20% of the patients with isolated medial malleolar fracture. Three patients with Weber B and one patient with Weber C fracture have occult syndesmosis instability after screw removal. Osteochondral lesion was present in no patient with Weber A fracture, 26% of the Weber B cases, 24% of the Weber C cases, and 20% of isolated medial malleolar fracture cases. The association between the presence of deep deltoid ligament tear and syndesmosis disruption (warranting syndesmosis screw fixation) in Weber B cases was statistically significant but not in Weber C cases. There was no statistically significant association between the presence of posterior malleolar fracture and syndesmosis instability that warrant screw fixation. Ankle arthroscopy is a useful adjuvant tool to understand the severity and complexity of acute ankle fracture. Direct arthroscopic visualization ensures detection and evaluation of intra-articular fractures, syndesmosis disruption, and associated osteochondral lesions and ligamentous injuries. Level IV, case series

  8. Size-corrected BMD decreases during peak linear growth: implications for fracture incidence during adolescence.

    Science.gov (United States)

    Faulkner, Robert A; Davison, K Shawn; Bailey, Donald A; Mirwald, Robert L; Baxter-Jones, Adam D G

    2006-12-01

    Peak adolescent fracture incidence at the distal end of the radius coincides with a decline in size-corrected BMD in both boys and girls. Peak gains in bone area preceded peak gains in BMC in a longitudinal sample of boys and girls, supporting the theory that the dissociation between skeletal expansion and skeletal mineralization results in a period of relative bone weakness. The high incidence of fracture in adolescence may be related to a period of relative skeletal fragility resulting from dissociation between bone expansion and bone mineralization during the growing years. The aim of this study was to examine the relationship between changes in size-corrected BMD (BMDsc) and peak distal radius fracture incidence in boys and girls. Subjects were 41 boys and 46 girls measured annually (DXA; Hologic 2000) over the adolescent growth period and again in young adulthood. Ages of peak height velocity (PHV), peak BMC velocity (PBMCV), and peak bone area (BA) velocity (PBAV) were determined for each child. To control for maturational differences, subjects were aligned on PHV. BMDsc was calculated by first regressing the natural logarithms of BMC and BA. The power coefficient (pc) values from this analysis were used as follows: BMDsc = BMC/BA(pc). BMDsc decreased significantly before the age of PHV and then increased until 4 years after PHV. The peak rates in radial fractures (reported from previous work) in both boys and girls coincided with the age of negative velocity in BMDsc; the age of peak BA velocity (PBAV) preceded the age of peak BMC velocity (PBMCV) by 0.5 years in both boys and girls. There is a clear dissociation between PBMCV and PBAV in boys and girls. BMDsc declines before age of PHV before rebounding after PHV. The timing of these events coincides directly with reported fracture rates of the distal end of the radius. Thus, the results support the theory that there is a period of relative skeletal weakness during the adolescent growth period caused, in

  9. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  10. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  11. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  12. [Medial versus lateral plating in distal tibial fractures: a prospective study of 40 fractures].

    Science.gov (United States)

    Encinas-Ullán, C A; Fernandez-Fernandez, R; Rubio-Suárez, J C; Gil-Garay, E

    2013-01-01

    Tibial plafond fractures are one of the most challenging injuries in orthopaedic surgery. Their results could be improved by following the new guidelines for the management, and modern plating techniques. The results and complication rate between anteromedial and anterolateral approach for open reduction and internal fixation of these fractures were compared. A study was conducted on 40 patients treated by open reduction an internal fixation between 2007 and 2008. The surgical approach was selected by the surgeon in charge, depending on fracture pattern and skin situation. Patients were evaluated clinically and radiographically by an independent orthopaedic surgeon, not involved in the surgical procedure, using clinical (American Orthopaedic Foot and Ankle Society score) and radiological criteria at a minimum of two years. The appearance of complications after both approaches was recorded. Forty patients were included. The mean age was 53 years, with 24 males and 16 females. Seventeen of the injuries were of high energy, and there were 8 open fractures (3 of type i, 4 type ii and one type iii), and 12 of the closed injuries were grade ii or iii in the Tscherne classification. Six patients (15%) had associated injuries. At final follow-up there were 33 (82%) excellent or good results. No statistical differences were found between either surgical approach regarding time to bone union, rate of delayed union and infection rate. Three plates of the anteromedial group and none of the anterolateral group needed to be removed. Open reduction and internal fixation of distal tibia fractures produced reliable results, with no statistical differences found between anteromedial and anterolateral surgical approaches. Clinical and radiological results and complication rate were mainly related to the fracture type. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  13. Early functional postoperative therapy of distal radius fracture with a dynamic orthosis: results of a prospective randomized cross-over comparative study.

    Directory of Open Access Journals (Sweden)

    Fabian M Stuby

    Full Text Available This study was conducted according to GCP criteria as a prospective randomized cross-over study. The primary goal of the study was to determine clinical findings and patient satisfaction with postoperative treatment. 29 patients with a distal radius fracture that was surgically stabilized from volar and who met the inclusion criteria were enrolled over a 12-month period. Each patient randomly received either a dorsal plaster splint or a vacuum-fit flexible but blocked orthosis applied postoperatively in the operating theatre to achieve postoperative immobilization. After one week all patients were crossed over to the complementary device maintaining the immobilization until end of week 2. After week 2 both groups were allowed to exercise wrist mobility with a physiotherapist, in the orthosis group the device was deblocked, thus allowing limited wrist mobility. After week 4 the devices were removed in both groups. Follow-up exams were performed after postoperative weeks 1, 2, 4 and 12.Results were determined after week 1 and 2 using SF 36 and a personally compiled questionnaire; after weeks 4 and 12 with a clinical check-up, calculation of ROM and the DASH Score. Comparison of the two groups showed a significant difference in ROM for volar flexion after 4 weeks, but no significant differences in DASH Score, duration of disability or x-ray findings. With regard to satisfaction with comfort and hygiene, patients were significantly more satisfied with the dynamic orthosis, and 23 of the 29 patients would prefer the flexible vacuum orthosis in future.German Clinical Trials Register (DRKS DRKS00006097.

  14. Odontoid fractures: A retrospective analysis of 53 cases

    Directory of Open Access Journals (Sweden)

    Shetty Arjun

    2009-01-01

    Full Text Available Background: The management of odontoid fracture has evolved but controversy persists as to the best method for Type II odontoid fractures with or without atlantoaxial (AA instability. The anterior odontoid screw fixation can be associated with significant morbidity while delayed odontoid screw fixation has shown to be associated with reasonable good fusion rates. We conducted a retrospective analysis to evaluate the outcome of a trial of conservative management in type II odontoid fractures without atlantoaxial instability (Group A followed by delayed odontoid screw fixation in cases in which fusion was not achieved by conservative treatment. The outcome of type II odontoid fracture with AA subluxation (Group B was also analysed where closed reduction on traction could be achieved and in those atlantoaxial subluxations that were irreducible an intraoperative reduction was done. Materials and Methods: A retrospective evaluation of 53 cases of odontoid fractures treated over a 9-year period is being reported. All odontoid fractures without AA instability (n=29 were initially managed conservatively. Three patients who did not achieve union with conservative management were treated with delayed anterior screw fixation. Twenty-four cases of odontoid fractures were associated with AA instability; 17 of them could be reduced with skeletal traction and were managed with posterior fusion and fixation. Of the seven cases that were irreducible, the initial three cases were treated by odontoid excision followed by posterior fusion and fixation; however, in the later four cases, intra operative reduction was achieved by a manipulation procedure, and posterior fusion and fixation was performed. Results: Twenty-six of 29 cases of odontoid fracture without AA instability achieved fracture union with conservative management whereas the remaining three patients achieved union following delayed anterior odontoid screw fixation. 17 out of 24 odontoid fracture with

  15. Surgical Management of a Mandible Subcondylar Fracture

    Directory of Open Access Journals (Sweden)

    Dong Hee Kang

    2012-07-01

    Full Text Available Open reduction and anatomic reduction can create better function for the temporomandibularjoint, compared with closed treatment in mandible fracture surgery. Therefore, the doubleminiplate fixation technique via mini-retromandibular incision was used in order to makethe most stable fixation when performing subcondylar fracture surgery. Those approachesprovide good visualization of the subcondyle from the posterior edge of the ramus, allow thesurgeon to work perpendicularly to the fracture, and enable direct fracture management.Understanding the biomechanical load in the fixation of subcondylar fractures is alsonecessary in order to optimize fixation methods. Therefore, we measured the biomechanicalloads of four different plate fixation techniques in the experimental model regardingmandibular subcondylar fractures. It was found that the loads measured in the two-platefixation group with one dynamic compression plate (DCP and one adaption plate showed thehighest deformation and failure loads among the four fixation groups. The loads measuredin the one DCP plate fixation group showed higher deformation and failure loads than theloads measured in the two adaption plate fixation group. Therefore, we conclude that theselection of the high profile plate (DCP is also important in order to create a stable load in thesubcondylar fracture.

  16. The application of closed reduction internal fixation and iliac bone block grafting in the treatment of acute displaced femoral neck fractures.

    Directory of Open Access Journals (Sweden)

    Zhiyong Li

    Full Text Available OBJECTIVE: This study aimed to evaluate the preliminary clinical and radiographic outcomes of acute displaced femoral neck fracture treated by closed reduction and internal fixation (CRIF with free iliac bone block grafting with comparison to a routine protocol of CRIF without bone grafting. METHODS: From December 2008 to February 2010, 220 adult patients with acute displaced femoral neck fractures were enrolled in this study. In study group, there were 124 patients (57 males, 67 females with a mean age of 44.8 years (range, 20-64 years. There were 70 transcervical fractures and 54 subcapital fractures. The patients were treated by CRIF and free iliac bone block grafting. The control group consisted of 96 adult patients (46 males, 50 females with a mean age of 46.3 years (range, 23-64 years. There were 61 transcervical fractures and 35 subcapital fractures. The patients in control group were treated by CRIF without bone grafting. RESULTS: In study group, 112 patients were followed up for an average of 27.4 months (range, 24-34 months. All fractures healed within 5 months. However, 10 patients presented AVN of the femoral heads. The mean Harris score was 88.6 (range, 41-100. In control group, 68 patients were followed up for an average of 31.2 months (range, 24-42 months. The rates of AVN of the femoral head and fracture nonunion in control group were 26.5% (18/68 and 16.2% (11/68, respectively, significantly higher than those in study group (both P<0.05. The mean Harris score in control group was 83.8 (41-100, significantly lower than that in study group (P<0.05. CONCLUSION: Acute displaced femoral neck fractures can be treated by CRIF and free iliac bone block grafting in a minimally invasive manner. This technique can guarantee uneventful fracture healing and significantly reduce the rate of femoral head osteonecrosis.

  17. Complications associated with distraction plate fixation of wrist fractures.

    Science.gov (United States)

    Hanel, Douglas P; Ruhlman, Scott David; Katolik, Leo I; Allan, Christopher H

    2010-05-01

    This article discusses the major and minor complications of distal plating in the light of a cohort study carried out by the authors, who reviewed all patients undergoing bridge distraction plate fixation of distal radius fractures by three surgeons in a single level I trauma center. The article discusses the effectiveness and the complication rates associated with the technique. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  18. Allogenic bone rods with freeze drying and gamma rays irradiation for treatment of fracture

    International Nuclear Information System (INIS)

    Zhou Zhenbin

    1999-01-01

    Opened reduction and internal fixation are the usual treatment of fracture, but both methods need a second operation for removal implants. The benefits of the bone rods are that they can avoid the removement of internal fixation and will be absorbed spontaneously. The bone rods are made of allogeneic compact bones with freeze-drying and gamma rays irradiation supplied by Shanxi Provincial Tissue Bank. The purpose of this study is to evaluate allograft reaction, the stability of the internal fixation, osteoinduction in the treatment of fracture using allogeneic bone rods with freeze drying and gamma rays irradiation. From May 1997 to May 1998, fourteen cases (male 12, female 2) of treatment were reviewed. The mean age was 37.3 (21-5 1). There were 3 medial malleolus fractures, 7 tibia and fibula fractures, 1 ulna and radius fracture, 1 lateral condyle of humerus fracture. The clinical results were satisfactory. Because the strength of the bone rods are weaker than that of screws, the bone rods are only indicated in the fixation of cancellous bones fracture and unloaded bone fracture. It can be used as a supplementary fixation of loaded bone. It is not indicated for fixation of comminuted fracture. More than two bone rods may be used in the fixation of fracture in order to get stability of the fracture and decrease stress between rods which will prevent the break of the bone rods. Allogeneic bone rods with freeze-drying and gamma rays irradiation can be used as implants of non-immunogenicity. There are no allograft reactions in all cases (including fever, leukocytosis, exudation or swelling in the wound). Although plenty of experimental studies have showed that freeze drying with gamma rays irradiation (below 50 KGy) would not destroy BMP of bone allograft, but there is no osteoinduction in our cases. The healing of a fracture and bridging external callus are similar as other operations. This new technique may have the following advantages compare with the screws: 1

  19. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    , 31-A2) and intertrochanteric (31-A3) fractures is considered an important approach because of their different behaviour at reduction. Pertrochanteric fractures occurred more frequently (81.5%); the patients' age was higher (80 years on the average) and women outnumbered men at a ratio of 3:1. Intertrochanteric fractures were found in significantly younger patients (average, 72 years), with a women-to-men ratio of 1.3:1. Stable pertrochanteric fractures (31-A1) were preferably indicated for DHS surgery. Unstable pertrochanteric (31-A2) and intertrochanteric (31- A3) fractures were treated with a nail. The patients underwent surgery on the day of injury or the next day. In the case of contraindications to an urgent intervention, surgery was performed after the patient's medical condition had stabilised. The number of complications was largely related to technical errors, such as insufficient reduction or an incorrectly inserted implant. Intertrochanteric fractures were associated with a higher occurrence of complications. No implant can compensate for errors due to surgery. Serious complications can be reduced by the correct assessment of fracture type, the use of an appropriate operative technique and early treatment of potential complications. The necessity of restoring continuity in the medial cortex of the femoral neck (Adams' arch) is the requirement that should be observed. Pseudoarthrosis or varus malalignment in a healed hip should be managed by valgus osteotomy. When the femoral head or the acetabulum is damaged, total hip arthroplasty is indicated. A prerequisite for successful surgical outcome is urgently and correctly performed osteosynthesis allowing for early rehabilitation and mobilisation of the patient.

  20. Spectral radius of graphs

    CERN Document Server

    Stevanovic, Dragan

    2015-01-01

    Spectral Radius of Graphs provides a thorough overview of important results on the spectral radius of adjacency matrix of graphs that have appeared in the literature in the preceding ten years, most of them with proofs, and including some previously unpublished results of the author. The primer begins with a brief classical review, in order to provide the reader with a foundation for the subsequent chapters. Topics covered include spectral decomposition, the Perron-Frobenius theorem, the Rayleigh quotient, the Weyl inequalities, and the Interlacing theorem. From this introduction, the

  1. Percutaneous treatment of insufficiency fractures. Principles, technique and review of literature

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Datir, Abhijit; D'Souza, Sharon L.; D'Souza, Logan S.; Gunda, Divya; Morelli, John; Johnson, Michael Brandon; Nabavizadeh, Nima

    2010-01-01

    Insufficiency fractures of the pelvis, sacrum, spine, and long bones are painful, debilitating, and are common consequences of osteoporosis. Conventional treatment for these fractures varies from conservative therapy to surgery with plate and screw fixation. The former fails to address the underlying problem of fracture and frequently does not alleviate symptoms, while the latter is invasive and not always possible in older populations with low bone density and numerous co-morbidities. Osseous augmentation with polymethylmethacrylate (PMMA) has been used for over two decades to treat fractures related to osteoporosis, but has not been commonly used to treat fractures outside of the vertebral bodies. Osseous augmentation with PMMA is an image-guided procedure and various techniques have been utilized to treat fracture in different locations. We describe various techniques for image-guided osseous augmentation and treatment of insufficiency fractures with bothPMMA and allograft bone for fractures of the pelvis including sacrum, acetabulum, pubic symphysis, pubic rami ilium; appendicular skeleton including distal radius, proximal femur, and vertebral body. We also describe the potential risks and complications associated with percutaneous treatment of insufficiency fractures and techniques to avoid the pitfalls of the various procedures. We will present the process for patient follow-up and data regarding the pre- and postprocedure pain response in patients undergoing treatment for pelvic insufficiency fractures. (orig.)

  2. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    Science.gov (United States)

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  3. Surgical treatment of open pilon fractures.

    Science.gov (United States)

    Zeng, Xian-tie; Pang, Gui-gen; Ma, Bao-tong; Mei, Xiao-long; Sun, Xiang; Wang, Jia; Jia, Peng

    2011-02-01

    To discuss the methods, timing and clinical outcomes of surgical treatment for open pilon fractures. From April 2003 to July 2008, 28 patients with open pilon fractures were treated. All had type C fractures according to the Arbeitsgemeinschaft für osteosynthesefragen-Association for the Study of Internal Fixation (AO/ASIF) classification. Three operative methods were applied, the methods being determined by the types of fracture, soft tissue damage and time interval after injury. Seven cases were treated by debridement and internal fixation with plate; 19 by limited internal fixation combined with external fixation; and 2 by delayed surgery. The clinical outcomes were evaluated by the Burwell-Charnley score. All cases were followed up for from 6 to 48 months (average 24 months). The Burwell-Charnley score of clinical outcomes: anatomic reduction achieved in 12 cases, functional reduction in 15, and unsatisfactory reduction in 1. The healing time was from 2.5 to 11 months (average 4.7 months). Two cases had delayed union. According to the American Orthopaedic Foot and Ankle Society (AOFAS) scale for the ankle joint, there were excellent results in 8 cases, good in 14, fair in 5 and poor in 1. Complications included four cases of skin superficial sloughing, two of superficial infection, one of deep infection, two of delayed fracture union and ten of post-traumatic arthritis. It is important to perform appropriate surgeries for open pilon fracture according to fracture classification, different damage to skin and tissue and time interval after injury. Thorough debridement, proper use of anti-infective medication, appropriate bone grafting, and postoperative ankle function exercise can reduce the occurrence of complications. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  4. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    Science.gov (United States)

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  5. Clinical study of emergency treatment and selective closed reduction for the treatment of supracondylar humerus fracture in children

    Directory of Open Access Journals (Sweden)

    Wei Zhong

    2016-11-01

    Full Text Available Objective: To study the effect of emergency treatment, selective closed reduction combined with percutaneous Kirschner wire fixation on the treatment of Gartland type-II and type-III supracondylar humerus fracture. Methods: Children who sustained the Gartland type-II and type-III supracondylar fractures of humerus treated with selective closed reduction combined with percutaneous Kirschner wire fixation in our hospital from May 2012 to August 2015 were analyzed retrospectively. They were divided into group A (emergency operation group and group B (selective operation group according to different operation timing. Perioperative situation, blood biochemical parameters, swelling degree and elbow joint function of affected limb were compared between two groups. Results: Operation time for patients of group A was significantly shorter than that of group B [(17.19 ± 2.85 vs. (21.43 ± 3.91 min], and frequency of fluoroscopy during operation of group A was obviously less than that of group B [(6.03 ± 0.95 vs. (7.61 ± 0.92 times]. Swelling index of affected limb in group A at 3 days, 5 days and 7 days after injury was all significantly lower than that in group B [(1.20 ± 0.17 vs. (1.38 ± 0.14, (1.13 ± 0.13 vs. (1.30 ± 0.18, (1.02 ± 0.15 vs. (1.22 ± 0.15]. Hospital for special surgery score at 1 week, 2 weeks, 3 and 4 weeks after removing Kirschner wire had no significant difference between group A and B (88.75 ± 10.18 vs. (89.14 ± 10.52, (94.22 ± 10.85 vs. (93.85 ± 11.08, (95.52 ± 11.27 vs. (95.92 ± 12.19, (95.43 ± 10.96 vs. (96.02 ± 11.38. Contents of serum alanine transaminase, aspertate aminotransferase, total protein, albumin and C-reactive protein in perioperative period had no obvious difference between patients in group A and B. Conclusions: Emergency closed reduction combined with percutaneous Kirschner wire fixation for Gartland type-II and type-III supracondylar humerus fracture in children has less trauma, low swelling degree

  6. [Clinical practice guideline on closed tibial plateau fractures in adulthood].

    Science.gov (United States)

    Ocegueda-Sosa, Miguel Ángel; Valenzuela-Flores, Adriana Abigail; Aldaco-García, Víctor Daniel; Flores-Aguilar, Sergio; Manilla-Lezama, Nicolás; Pérez-Hernández, Jorge

    2013-01-01

    Closed tibiae plateau fractures are common injuries in the emergency room. The optimal treatment is not well defined or established. For this reason, there are several surgical management options: open reduction and internal fixation, closed reduction and percutaneous synthesis, external fixation, and even conservative treatment for this kind of fracture. The mechanism of production of this fracture is through large varus or valgus deformation to which is added a factor of axial load. The trauma may be direct or indirect. The degree of displacement, fragmentation and involvement of soft tissues like ligaments, menisci, vascular and nerve structures are determined by the magnitude of the force exerted. Any intra-articular fracture treatment can lead to an erroneous instability, deformity and limitation of motion with subsequent arthritic changes, leading to joint incongruity, limiting activity and significantly altering the quality of life. Open reduction and internal fixation with anatomic restitution is the method used in this type of fracture. However, the results of numerous publications can be questioned due to the inclusion in the same study of fractures treated with very different methods.

  7. Prevalence of silent vertebral fractures detected by vertebral fracture assessment in young Portuguese men with hyperthyroidism.

    Science.gov (United States)

    Barbosa, Ana Paula; Rui Mascarenhas, Mário; Silva, Carlos Francisco; Távora, Isabel; Bicho, Manuel; do Carmo, Isabel; de Oliveira, António Gouveia

    2015-02-01

    Hyperthyroidism is a risk factor for reduced bone mineral density (BMD) and osteoporotic fractures. Vertebral fracture assessment (VFA) by dual-energy X-ray absorptiometry (DXA) is a radiological method of visualization of the spine, which enables patient comfort and reduced radiation exposure. This study was carried out to evaluate BMD and the prevalence of silent vertebral fractures in young men with hyperthyroidism. We conducted a cross-sectional study in a group of Portuguese men aged up to 50 years and matched in hyperthyroidism (n=24) and control (n=24) groups. A group of 48 Portuguese men aged up to 50 years was divided and matched in hyperthyroidism (n=24) and control (n=24) groups. BMD (g/cm(2)) at L1-L4, hip, radius 33%, and whole body as well as the total body masses (kg) were studied by DXA. VFA was used to detect fractures and those were classified by Genant's semiquantitative method. No patient had previously been treated for hyperthyroidism, osteoporosis, or low bone mass. Adequate statistical tests were used. The mean age, height, and total fat mass were similar in both groups (P≥0.05). The total lean body mass and the mean BMD at lumbar spine, hip, and whole body were significantly decreased in the hyperthyroidism group. In this group, there was also a trend for an increased prevalence of reduced BMD/osteoporosis and osteoporotic vertebral fractures. The results obtained using VFA technology (confirmed by X-ray) suggest that the BMD changes in young men with nontreated hyperthyroidism may lead to the development of osteoporosis and vertebral fractures. This supports the pertinence of using VFA in the routine of osteoporosis assessment to detect silent fractures precociously and consider early treatment. © 2015 European Society of Endocrinology.

  8. The proton radius puzzle

    Science.gov (United States)

    Bonesini, Maurizio

    2017-12-01

    The FAMU (Fisica degli Atomi Muonici) experiment has the goal to measure precisely the proton Zemach radius, thus contributing to the solution of the so-called proton radius "puzzle". To this aim, it makes use of a high-intensity pulsed muon beam at RIKEN-RAL impinging on a cryogenic hydrogen target with an high-Z gas admixture and a tunable mid-IR high power laser, to measure the hyperfine (HFS) splitting of the 1S state of the muonic hydrogen. From the value of the exciting laser frequency, the energy of the HFS transition may be derived with high precision ( 10-5) and thus, via QED calculations, the Zemach radius of the proton. The experimental apparatus includes a precise fiber-SiPMT beam hodoscope and a crown of eight LaBr3 crystals and a few HPGe detectors for detection of the emitted characteristic X-rays. Preliminary runs to optimize the gas target filling and its operating conditions have been taken in 2014 and 2015-2016. The final run, with the pump laser to drive the HFS transition, is expected in 2018.

  9. Study on elastic-plastic fracture toughness test in high temperature water

    International Nuclear Information System (INIS)

    Miura, Yasufumi

    2016-01-01

    Structural integrity of internal components in light water reactors is important for the safety of operation and service lifetime. Fracture toughness is important parameter for structural integrity assessment of nuclear power plant. In general, fracture toughness of materials which compose the components in light water reactor is obtained with fracture toughness tests in air although some components are subjected to high temperature water because of the difficulty of fracture toughness test in high temperature water. However, the effects of high temperature water and hydrogen on fracture behavior of the structural materials in nuclear power plant such as low alloy steel, cast austenitic stainless steel, and Ni base alloy are concerned recently. In this study, elastic-plastic fracture toughness test of low alloy steel in simulated BWR water environment was studied. Fracture toughness test in high temperature water with original clip gage and normalization data reduction technique was established. The difference of fracture toughness J_Q tested in air between using elastic unload compliance method and normalization data reduction technique was also discussed. As a result, obtained value with normalization data reduction technique tended to be higher than the value with elastic unload compliance. (author)

  10. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Science.gov (United States)

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  11. Pediatric mandibular fractures treated by rigid internal fixation.

    Science.gov (United States)

    Wong, G B

    1993-09-01

    Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.

  12. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  13. Groundwater degassing in fractured rock: Modelling and data comparison

    Energy Technology Data Exchange (ETDEWEB)

    Jarsjoe, J.; Destouni, G. [Royal Inst. of Tech., Stockholm (Sweden). Water Resources Engineering

    1998-11-01

    Dissolved gas may be released from deep groundwater in the vicinity of open boreholes and drifts, where the water pressures are relatively low. Degassing of groundwater may influence observations of hydraulic conditions made in drifts, interpretation of experiments performed close to drifts, and buffer mass and backfill performance, particularly during emplacement and repository closure. Under certain conditions, considerable fracture inflow and transmissivity reductions have been observed during degassing experiments in the field and in the laboratory; such reductions affect the outcome and interpretation of both hydraulic and tracer tests. We develop models for the estimation of the resulting degree of fracture gas saturation and the associated transmissivity reduction due to groundwater degassing in fractured rock. Derived expressions for bubble trapping probability show that fracture aperture variability and correlation length influence the conditions for capillary bubble trapping and gas accumulation. The laboratory observations of bubble trapping in an Aespoe fracture replica are consistent with the prediction of a relatively high probability of bubble trapping in this fracture. The prediction was based on the measured aperture distribution of the Aespoe fracture and the applied hydraulic gradient. Results also show that the conceptualisation of gas and water occupancy in a fracture greatly influences model predictions of gas saturation and relative transmissivity. Images from laboratory degassing experiments indicate that tight apertures are completely filled with water, whereas both gas and water exist in wider apertures under degassing conditions; implementation of this relation in our model resulted in the best agreement between predictions and laboratory observations. Model predictions for conditions similar to those prevailing in field for single fractures at great depths indicate that degassing effects in boreholes should generally be small, unless the

  14. Critical cladding radius for hybrid cladding modes

    Science.gov (United States)

    Guyard, Romain; Leduc, Dominique; Lupi, Cyril; Lecieux, Yann

    2018-05-01

    In this article we explore some properties of the cladding modes guided by a step-index optical fiber. We show that the hybrid modes can be grouped by pairs and that it exists a critical cladding radius for which the modes of a pair share the same electromagnetic structure. We propose a robust method to determine the critical cladding radius and use it to perform a statistical study on the influence of the characteristics of the fiber on the critical cladding radius. Finally we show the importance of the critical cladding radius with respect to the coupling coefficient between the core mode and the cladding modes inside a long period grating.

  15. SUPRACONDYLAR FRACTURE OF THE HUMERUS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Nikola Bojović

    2012-09-01

    Full Text Available Humeral supracondylar fractures are the second most common fractures seen in children and young teenagers (16.6%. They represent 60-70% of all the elbow fractures. The maximum incidence is found between the fifth and seventh year of age, slightly more often in boys and on non-dominant hand. We performed a retrospective study in our clinic which included 105 patients admitted to our facility during the period from January, 2008 to April, 2012. The included patients had humeral supracondylar fracture either type 2 or type 3 (Gartland classification. At the moment of admission the median age was 7.26 years. All the patients were treated during the first 12 hours, with no more than two attempts of closed reposition. Sixteen patients with type 2 fracture were treated by analgosedation, closed reduction followed by cast immobilization. All other patients were treated after induction of general anesthesia. Sixteen patients were treated by percutaneous fixation of the fragments after closed reduction and 73 were treated with open reduction and pinning with different number and positions of „К“ wires. None of the patients had deep tissue infection; four patients had pin site infection. Three patients had cubitus varus deformity, two patients had elbow contracture, five patients had temporary limitation in extension, and one patient had iatrogenic lesion of the ulnar nerve. This makes 14.2% complication rate in our series. All the fractures healed in the expected period (3–4 weeks. Bauman’s angle, carrying angle and functional factor were measured postoperatively. Closed reposition with pinning, using radiographic control, for the dislocated supracondylar humeral fractures is the safest, as well as the least time consuming and cost-effective method. We also suggest treating these fractures within 12 hours and conversion of closed into open reposition in case of lacking crepitations (possibility of interposition of soft tissues between fragments.

  16. An iterative algorithm for calculating stylus radius unambiguously

    International Nuclear Information System (INIS)

    Vorburger, T V; Zheng, A; Renegar, T B; Song, J-F; Ma, L

    2011-01-01

    The stylus radius is an important specification for stylus instruments and is commonly provided by instrument manufacturers. However, it is difficult to measure the stylus radius unambiguously. Accurate profiles of the stylus tip may be obtained by profiling over an object sharper than itself, such as a razor blade. However, the stylus profile thus obtained is a partial arc, and unless the shape of the stylus tip is a perfect sphere or circle, the effective value of the radius depends on the length of the tip profile over which the radius is determined. We have developed an iterative, least squares algorithm aimed to determine the effective least squares stylus radius unambiguously. So far, the algorithm converges to reasonable results for the least squares stylus radius. We suggest that the algorithm be considered for adoption in documentary standards describing the properties of stylus instruments.

  17. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  18. Surgical Management of a Mandible Subcondylar Fracture

    Directory of Open Access Journals (Sweden)

    Dong Hee Kang

    2012-07-01

    Full Text Available Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP is also important in order to create a stable load in the subcondylar fracture.

  19. OUTCOME OF INTERTROCHANTERIC FRACTURES TREATED WITH SHORT FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Yadkikar Shriniwas V, Yadkikar Vishnu S, Patel Mayank, Dhruvilkumar Gandhi, Kunkulol Rahul

    2015-07-01

    Full Text Available Aim: To study the functional and anatomical outcome of Inter trochanteric fractures of femur treated with Short femoral nail. Method: This was retrospective study carried out in which 60 patients (50 Male & 10 Female of 5th to 8th decade of life who underwent Short femoral nail fixation for both Stable & unstable Inter Trochanteric fractures. From the records each patient data was assessed for time required for mobilization, average fracture healing time, degree and grade of hip range of movements, complications, anatomical reduction achieved using Short femoral nail fixation. Results: 55 cases achieved Anatomical reduction. Good to Excellent Hip range of Motion was in 55 (90 % cases. Fracture union was seen in all cases. No evidence of Z Effect, AVN of femoral head, Implant failure, Fracture of femoral shaft below the Nail tip was seen in any case, However Reverse Z Effect was seen in 4 & shortening of less than 2 cm was seen in 2 cases, External rotation of 10 degree was seen in1 case. Average fracture Union time was 14 weeks. Conclusion: Short femoral nail appears to be better implant for fixation of both Stable & unstable Inter Trochanteric fractures as it fulfills the biomechanical demands being minimally invasive, less blood loss , it prevents excessive varus collapse at fracture site, produces less stress riser effect below the nail tip, Short operative time, Facilitates early mobilization & functional recovery of patients. But Anatomical fracture reduction & optimal implant placement are absolutely must for better results.

  20. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture.

  1. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available The incidence of condylar fractures is high,but the management of fractures of the mandibularcondyle continues to be controversial. Historically, maxillomandibular fixation, externalfixation, and surgical splints with internal fixation systems were the techniques commonlyused in the treatment of the fractured mandible. Condylar fractures can be extracapsularor intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on theage of the patient, the co-existence of other mandibular or maxillary fractures, whether thecondylar fracture is unilateral or bilateral, the level and displacement of the fracture, thestate of dentition and dental occlusion, and the surgeonnds on the age of the patient, theco-existence of othefrom which it is difficult to recover aesthetically and functionally;anappropriate treatment is required to reconstruct the shape and achieve the function oftheuninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, andcomplication prevention are required. In particular, as mandibular condyle fracture may causelong-term complications such as malocclusion, particularly open bite, reduced posterior facialheight, and facial asymmetry in addition to chronic pain and mobility limitation, great cautionshould be taken. Accordingly, the authors review a general overview of condyle fracture.

  2. Current Concepts in the Mandibular Condyle Fracture Management Part I: Overview of Condylar Fracture

    Science.gov (United States)

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    The incidence of condylar fractures is high, but the management of fractures of the mandibular condyle continues to be controversial. Historically, maxillomandibular fixation, external fixation, and surgical splints with internal fixation systems were the techniques commonly used in the treatment of the fractured mandible. Condylar fractures can be extracapsular or intracapsular, undisplaced, deviated, displaced, or dislocated. Treatment depends on the age of the patient, the co-existence of other mandibular or maxillary fractures, whether the condylar fracture is unilateral or bilateral, the level and displacement of the fracture, the state of dentition and dental occlusion, and the surgeonnds on the age of the patient, the co-existence of othefrom which it is difficult to recover aesthetically and functionally;an appropriate treatment is required to reconstruct the shape and achieve the function ofthe uninjured status. To do this, accurate diagnosis, appropriate reduction and rigid fixation, and complication prevention are required. In particular, as mandibular condyle fracture may cause long-term complications such as malocclusion, particularly open bite, reduced posterior facial height, and facial asymmetry in addition to chronic pain and mobility limitation, great caution should be taken. Accordingly, the authors review a general overview of condyle fracture. PMID:22872830

  3. A New Method for Surgical Treatment of Subcondylar Fractures: A Case Report

    Directory of Open Access Journals (Sweden)

    Gholamreza Shirani

    2017-12-01

    Full Text Available AbstractSubcondylar fractures are common in the maxillofacial region following direct trauma to the mandibular ramus. The literature is replete with articles written on the treatment of subcondylar fractures, encompassing a plethora of various surgical approaches; however, the best treatment procedure has remained controversial. Such fractures are either treated by open reduction with internal fixation or closed reduction with maxillomandibular fixation. In this article, we describe a new surgical method for treatment of subcondylar fractures.

  4. ARTHROSCOPIC TREATEMENT OF PATELLA FRACTURES IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Igor V. Timofeev

    2017-03-01

    Full Text Available Introduction. The frequency of patellar fractures is approximately 0.5% to 1.5% of all skeletal injuries. The following types of fractures can be distinguished: avulsive, transverse, longitudinal, and comminuted. In cases of displacement of more than 2–3 mm and quadriceps tendon injuries open reduction and internal fixation with the restoration of the articular surface is more preferable. In cases of longitudinal fractures, arthroscopy is regarded as a highly effective method of surgical treatment. Materials and methods. Using arthroscopy, we have operated on 4 patients with longitudinal fracture of the patella. The average age of the injured persons was 15.4 years (14–17. These were 3 males and 1 female. All patients had sport-related injuries. Because of the longitudinal fracture of the patella, the lateral knee extensor mechanism remained intact, and arthrosopy-assisted surgical intervention with closed reposition of fragments and transcutaneous wire fixation was performed without wire suturing. Results and discussion. Minimal invasiveness, the possibility of visual control over the recovery quality of patellar surface, the reliability of fragment fixation, and a significant reduction in the subsequent rehabilitation make arthroscopy a highly effective method of surgical treatment for patellar fractures.

  5. Strain-dependent partial slip on rock fractures under seismic-frequency torsion

    Science.gov (United States)

    Saltiel, Seth; Bonner, Brian P.; Ajo-Franklin, Jonathan B.

    2017-05-01

    Measurements of nonlinear modulus and attenuation of fractures provide the opportunity to probe their mechanical state. We have adapted a low-frequency torsional apparatus to explore the seismic signature of fractures under low normal stress, simulating low effective stress environments such as shallow or high pore pressure reservoirs. We report strain-dependent modulus and attenuation for fractured samples of Duperow dolomite (a carbon sequestration target reservoir in Montana), Blue Canyon Dome rhyolite (a geothermal analog reservoir in New Mexico), and Montello granite (a deep basement disposal analog from Wisconsin). We use a simple single effective asperity partial slip model to fit our measured stress-strain curves and solve for the friction coefficient, contact radius, and full slip condition. These observations have the potential to develop into new field techniques for measuring differences in frictional properties during reservoir engineering manipulations and estimate the stress conditions where reservoir fractures and faults begin to fully slip.

  6. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  7. Mandibular Condyle Fractures and Treatment Modalities

    Directory of Open Access Journals (Sweden)

    Halil ibrahim Kisa

    2014-08-01

    Full Text Available Maxillofacial injuries are most commonly associated with falls, motor and vehicle accidents, sports-related trauma, and interpersonel violence. The complexity of mandibular condyle region and its anatomic proximity to other craniofacial structures complicate diagnosis and treatment. Thus, treatment approaches of mandibular condyle fracture are still controversial. In the literature, different success rates are reported about observation versus treatment, closed reduction versus open reduction and fixation methods. In the present article, controversial issues related to mandibular condyle fractures were reviewed under the light of current literature. In conclusion, the simplest way that can be done with the least risk of complication should be chosen during treatment planning. In addition, current adjunctive treatment methods accelerating healing of fracture should be considered. [Archives Medical Review Journal 2014; 23(4.000: 658-671

  8. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  9. Ankle Fractures: The Operative Outcome

    Directory of Open Access Journals (Sweden)

    Ahmad Hafiz Z

    2011-03-01

    Full Text Available Ankle fractures are commonly seen in orthopaedic practice. This retrospective study of patients with ankle fractures who underwent surgical treatment in our institution from January 2000 to December 2003 was undertaken to analyze the common causes and patterns of ankle fractures; and the functional outcome of operative treatment for these fractures. Eighty patients were identified and reviewed. There were 65 male (81.3% and 15 female patients (18.7% with age ranging from 13 to 71 years old (mean, 32.3y. Common causes of ankle fractures were trauma (especially motor vehicle accidents, sports injuries and the osteoporotic bones in the elderly. Weber C (64.0% was the most common pattern of fracture at presentation. The most common operative treatment for ankle fractures was open reduction and internal fixation (73 patients, 91.2%. Excellent and good outcomes were achieved in 93.8% of cases when measured using the Olerud and Molander scoring system for foot and ankle. In conclusion, operative treatment for ankle fractures restores sufficient stability and allowed mobility of the ankle joint.

  10. Fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig

    2013-01-01

    Fractures of the proximal humerus have been diagnosed and managed since the earliest known surgical texts. For more than four millennia the preferred treatment was forceful traction, closed reduction, and immobilization with linen soaked in combinations of oil, honey, alum, wine, or cerate......, classification of proximal humeral fractures remains a challenge for the conduct, reporting, and interpretation of clinical trials. The evidence for the benefits of surgery in complex fractures of the proximal humerus is weak. In three systematic reviews I studied the outcome after locking plate osteosynthesis...

  11. Oil shale in situ research and development. Final report, August 1, 1977--December 22, 1978. [Hydraulic fractures; explosive rubblization

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, H.B.

    1978-01-01

    The selected Site Section 17 was prepared for hydraulic fracturing and explosive rubblization, and these operations accomplished. This report presents the field and laboratory preparations for the fracturing, rubblization, and evaluation operations. A series of four, parallel, hydraulically induced fractures was created during the first year. The evaluation tests showed the following about the four hydraulic fractures: (1) They were horizontal and narrow, that is, as large as 0.05 inches thick within a 50-foot radius and as small as 0.0011 inches thick for the average of all four fractures over the entire radius. (2) They extended at least 113 feet to the outer ring of production wells in a southeasterly direction. (3) They extended out beyond the outer ring of production wells in a northwesterly direction. (4) They had some degree of communication with the naturally fractured aquifer lying about them. And, (5), they had no significant communication with naturally fractured aquifer lying below them. The rubblization event took place on 21 August 1978, early in the second year of the contract. An evaluation of the areal extent, thickness, porosity, interconnectivity, and the influence of the explosion upon the adjacent aquifers was determined. The dynamic tests showed that the explosive slurry was loaded into the four hydraulic features and that detonation occurred simultaneously. The postrubblization evaluation demonstrated that: (1) There were four layers of damage of less than two-feet thick each, (2) massive permeability was apparent from all production wells, and (3) the permeability is in the form of block, open cracks rather than porous medium.

  12. Scattering of elastic waves on fractures randomly distributed in a three-dimensional medium

    Science.gov (United States)

    Strizhkov, S. A.; Ponyatovskaya, V. I.

    1985-02-01

    The purpose of this work is to determine the variation in basic characteristics of the wave field formed in a jointed medium, such as the intensity of fluctuations of amplitude, correlation radius, scattering coefficient and frequency composition of waves, as functions of jointing parameters. Fractures are simulated by flat plates randomly distributed and chaotically oriented in a three-dimensional medium. Experiments were performed using an alabaster model, a rectangular block measuring 50 x 50 x 120 mm. The plates were introduced into liquid alabaster which was then agitated. Models made in this way contain randomly distributed and chaotically oriented fractures. The influence of these fractures appears as fluctuations in the wave field formed in the medium. The data obtained in experimental studies showed that the dimensions of heterogeneities determined by waves in the jointed medium and the dimensions of the fractures themselves coincide only if the distance between fractures is rather great. If the distance between fractures is less than the wavelength, the dimensions of the heterogeneities located by the wave depend on wavelength.

  13. Incorporating Scale-Dependent Fracture Stiffness for Improved Reservoir Performance Prediction

    Science.gov (United States)

    Crawford, B. R.; Tsenn, M. C.; Homburg, J. M.; Stehle, R. C.; Freysteinson, J. A.; Reese, W. C.

    2017-12-01

    We present a novel technique for predicting dynamic fracture network response to production-driven changes in effective stress, with the potential for optimizing depletion planning and improving recovery prediction in stress-sensitive naturally fractured reservoirs. A key component of the method involves laboratory geomechanics testing of single fractures in order to develop a unique scaling relationship between fracture normal stiffness and initial mechanical aperture. Details of the workflow are as follows: tensile, opening mode fractures are created in a variety of low matrix permeability rocks with initial, unstressed apertures in the micrometer to millimeter range, as determined from image analyses of X-ray CT scans; subsequent hydrostatic compression of these fractured samples with synchronous radial strain and flow measurement indicates that both mechanical and hydraulic aperture reduction varies linearly with the natural logarithm of effective normal stress; these stress-sensitive single-fracture laboratory observations are then upscaled to networks with fracture populations displaying frequency-length and length-aperture scaling laws commonly exhibited by natural fracture arrays; functional relationships between reservoir pressure reduction and fracture network porosity, compressibility and directional permeabilities as generated by such discrete fracture network modeling are then exported to the reservoir simulator for improved naturally fractured reservoir performance prediction.

  14. The Proprioceptive System Regulates Morphologic Restoration of Fractured Bones

    Directory of Open Access Journals (Sweden)

    Ronen Blecher

    2017-08-01

    Full Text Available Successful fracture repair requires restoration of bone morphology and mechanical integrity. Recent evidence shows that fractured bones of neonatal mice undergo spontaneous realignment, dubbed “natural reduction.” Here, we show that natural reduction is regulated by the proprioceptive system and improves with age. Comparison among mice of different ages revealed, surprisingly, that 3-month-old mice exhibited more rapid and effective natural reduction than newborns. Fractured bones of null mutants for transcription factor Runx3, lacking functional proprioceptors, failed to realign properly. Blocking Runx3 expression in the peripheral nervous system, but not in limb mesenchyme, recapitulated the null phenotype, as did inactivation of muscles flanking the fracture site. Egr3 knockout mice, which lack muscle spindles but not Golgi tendon organs, displayed a less severe phenotype, suggesting that both receptor types, as well as muscle contraction, are required for this regulatory mechanism. These findings uncover a physiological role for proprioception in non-autonomous regulation of skeletal integrity.

  15. Extending Topological Approaches to Microseismic-Derived 3D Fracture Networks

    Science.gov (United States)

    Urbancic, T.; Bosman, K.; Baig, A.; Ardakani, E. P.

    2017-12-01

    Fracture topology is important for determining the fluid-flow characteristics of a fracture network. In most unconventional petroleum applications, flow through subsurface fracture networks is the primary source of production, as matrix permeability is often in the nanodarcy range. Typical models of reservoir discrete fracture networks (DFNs) are constructed using fracture orientation and average spacing, without consideration of how the connectivity of the fracture network aids the percolation of hydrocarbons back to the wellbore. Topological approaches to DFN characterization have been developed and extensively used in analysis of outcrop data and aerial photography. Such study of the surface expression of fracture networks is straight-forward, and the physical form of the observed fractures is directly reflected in the parameters used to describe the topology. However, this analysis largely ignores the three-dimensional nature of natural fracture networks, which is difficult to define accurately in geological studies. SMTI analysis of microseismic event distributions can produce DFNs, where each event is represented by a penny-shaped crack with radius and orientation determined from the frequency content of the waveforms and assessment of the slip instability of the potential fracture planes, respectively. Analysis of the geometric relationships between a set of fractures can provide details of intersections between fractures, and thus the topological characteristics of the fracture network. Extension of existing 2D topology approaches to 3D fracture networks is non-trivial. In the 2D case, a fracture intersection is a single point (node), and branches connect adjacent nodes along fractures. For the 3D case, intersection "nodes" become lines, and connecting nodes to find branches becomes more complicated. There are several parameters defined in 2D topology to quantify the connectivity of the fracture network. Equivalent quantities must be defined and calibrated

  16. On the proton radius problem

    OpenAIRE

    Giannini, M. M.; Santopinto, E.

    2013-01-01

    The recent values of the proton charge radius obtained by means of muonic-hydrogen laser spectroscopy are about $4\\%$ different from the electron scattering data. It has been suggested that the proton radius is actually measured in different frames and that, starting from a non relativistic quark model calculation, the Lorentz transformation of the form factors accounts properly for the discepancy. We shall show that the relation between the charge radii measured in different frames can be de...

  17. Understanding the mass-radius relation for sub-Neptunes: radius as a proxy for composition

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Eric D.; Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States)

    2014-09-01

    Transiting planet surveys like Kepler have provided a wealth of information on the distribution of planetary radii, particularly for the new populations of super-Earth- and sub-Neptune-sized planets. In order to aid in the physical interpretation of these radii, we compute model radii for low-mass rocky planets with hydrogen-helium envelopes. We provide model radii for planets 1-20 M {sub ⊕}, with envelope fractions 0.01%-20%, levels of irradiation 0.1-1000 times Earth's, and ages from 100 Myr to 10 Gyr. In addition we provide simple analytic fits that summarize how radius depends on each of these parameters. Most importantly, we show that at fixed H/He envelope fraction, radii show little dependence on mass for planets with more than ∼1% of their mass in their envelope. Consequently, planetary radius is to a first order a proxy for planetary composition, i.e., H/He envelope fraction, for Neptune- and sub-Neptune-sized planets. We recast the observed mass-radius relationship as a mass-composition relationship and discuss it in light of traditional core accretion theory. We discuss the transition from rocky super-Earths to sub-Neptune planets with large volatile envelopes. We suggest ∼1.75 R {sub ⊕} as a physically motivated dividing line between these two populations of planets. Finally, we discuss these results in light of the observed radius occurrence distribution found by Kepler.

  18. Recombination radius of a Frenkel pair and capture radius of a self-interstitial atom by vacancy clusters in bcc Fe

    International Nuclear Information System (INIS)

    Nakashima, Kenichi; Stoller, Roger E; Xu, Haixuan

    2015-01-01

    The recombination radius of a Frenkel pair is a fundamental parameter for the object kinetic Monte Carlo (OKMC) and mean field rate theory (RT) methods that are used to investigate irradiation damage accumulation in irradiated materials. The recombination radius in bcc Fe has been studied both experimentally and numerically, however there is no general consensus about its value. The detailed atomistic processes of recombination also remain uncertain. Values from 1.0a 0 to 3.3a 0 have been employed as a recombination radius in previous studies using OKMC and RT. The recombination process of a Frenkel pair is investigated at the atomic level using the self-evolved atomistic kinetic Monte Carlo (SEAKMC) method in this paper. SEAKMC calculations reveal that a self-interstitial atom recombines with a vacancy in a spontaneous reaction from several nearby sites following characteristic pathways. The recombination radius of a Frenkel pair is estimated to be 2.26a 0 by taking the average of the recombination distances from 80 simulation cases. In addition, we apply these procedures to the capture radius of a self-interstitial atom by a vacancy cluster. The capture radius is found to gradually increase with the size of the vacancy cluster. The fitting curve for the capture radius is obtained as a function of the number of vacancies in the cluster. (paper)

  19. Neck osteotomy for malunion of neglected radial neck fractures in children: a report of 2 cases.

    Science.gov (United States)

    Ceroni, Dimitri; Campos, José; Dahl-Farhoumand, Agnes; Holveck, Jérôme; Kaelin, André

    2010-01-01

    Radial neck fractures are a common injury in children as a result of a fall on an extended and supinated outstretched hand. We present 2 cases of osteotomy of the neck of the radius performed in 2 children with neglected radial neck fractures. Preoperatively, both patients complained of pain and severely reduced mobility of the elbow. Surgery was performed at 6 weeks and 3 months, respectively, after the initial injury and the 2 children were reviewed at 6 and 16 months follow-up. Osteotomies healed within the usual time and no avascular necrosis of the radial head, proximal radioulnar synostosis, or myositis ossificans were observed. The Mayo Elbow Performance Index Score improved significantly after the operation with the 2 patients rated as excellent. In this small series, we present a novel technique of proximal osteotomy of the radius to correct this deformity in children. Case series, level IV evidence.

  20. High incidence of osteochondral lesions after open reduction and internal fixation of displaced ankle fractures: Medium-term follow-up of 100 cases.

    Science.gov (United States)

    Regier, Marc; Petersen, Jan Philipp; Hamurcu, Ahmet; Vettorazzi, Eik; Behzadi, Cyrus; Hoffmann, Michael; Großterlinden, Lars G; Fensky, Florian; Klatte, Till Orla; Weiser, Lukas; Rueger, Johannes M; Spiro, Alexander S

    2016-03-01

    The incidence of osteochondral lesions (OCLs) in association with displaced ankle fractures has only been examined in two previous studies. In both studies magnetic resonance imaging (MRI) was performed prior to open reduction and internal fixation (ORIF). Because MRI may overdiagnose or overestimate the extent of OCLs in an acute trauma setting the aim of this study was to determine the incidence of OCLs after ORIF of displaced ankle fractures using MRI at medium-term follow-up, and to analyse if the severity of fracture or the clinical outcome correlates with the incidence of OCLs. Following institutional review board approval a total of 100 patients (mean age, 41.3 years; range, 17.9-64.3 years) with a displaced ankle fracture who had undergone ORIF according to the AO principles were included in this study. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used to quantify the clinical outcome and MR images were evaluated for OCLs of the talus and distal tibia after a mean of 34.5 months (range, 17.5-54.1 months). OCLs were found in 40.4% of the patients. Logistic regression revealed a significant correlation between the severity of fracture and the incidence of OCLs. Patients with a trimalleolar fracture (p=0.04) or an ankle fracture dislocation (p=0.003) had a significantly higher risk for developing an OCL compared to those with a type B fracture. Logistic regression also demonstrated a significant correlation between the clinical outcome (AOFAS score) and the incidence of OCLs (p=0.01). The risk for developing an OCL increases up to 5.6% when the AOFAS score decreases by one point. OCLs were frequently found in association with acute ankle fractures at medium-term follow-up, and the severity of fracture was associated with an increased number of OCLs. Considering the disadvantages of MRI including the high cost and limited availability, the results of this study may help to explain why anatomic surgical realignment of displaced

  1. Pediatric elbow fractures: a new angle on an old topic

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Kathleen H.; Anton, Christopher G. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Zingula, Shannon N. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Salisbury, Shelia R. [Cincinnati Children' s Hospital Medical Center, Biostatistics and Epidemiology, Cincinnati, OH (United States); Tamai, Junichi [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Orthopedics, Cincinnati, OH (United States)

    2016-01-15

    The three most common elbow fractures classically reported in pediatric orthopedic literature are supracondylar (50-70%), lateral condylar (17-34%), and medial epicondylar fractures (10%), with fractures of the proximal radius (including but not limited to fractures of the radial neck) being relatively uncommon (5-10%). Our experience at a large children's hospital suggests a different distribution. Our goals were (1) to ascertain the frequency of different elbow fracture types in a large pediatric population, and (2) to determine which fracture types were occult on initial radiographs but detected on follow-up. Review of medical records identified 462 children, median age 6 years and interquartile range for age of 4-8 years (range 0.8-18 years), who were diagnosed with elbow fractures at our institution over a 10-month period. Initial and follow-up radiographs were reviewed in blinded fashion independently by two experienced pediatric musculoskeletal radiologists to identify fracture types on initial and follow-up radiographs. The most common fractures included supracondylar (n = 258, 56%), radial neck (n = 80, 17%), and lateral condylar (n = 69, 15%). Additional fractures were seen on follow-up exams in 32 children. Of these, 25 had a different fracture type than was identified on initial radiographs. The most common follow-up fractures were olecranon (n = 23, 72%), coronoid process (n = 4, 13%) and supracondylar (n = 3, 9%). Olecranon fractures were significantly more common on follow-up radiographs than they were on initial radiographs (n = 33, 7%; P <.0001). Twenty-six children had more than one fracture type on the initial radiograph. The most common fracture combinations were radial neck with olecranon (n = 9) and supracondylar with lateral condylar (n = 9). Supracondylar fractures are the most frequent elbow fracture seen initially, followed by radial neck, lateral condylar, and olecranon fractures in a distribution different from what has been

  2. Developing a Fracture Model of the Granite Rocks Around the Research Tunnel at the Mizunami Underground Research Laboratory in Central Japan

    Science.gov (United States)

    Kalinina, E.; Hadgu, T.; Wang, Y.

    2017-12-01

    The Mizunami Underground Research Laboratory (MIU) is located in Tono area in Central Japan. It is operated by the Japan Atomic Energy Agency (JAEA) with the main purpose of providing scientific basis for the research and development of technologies needed for deep geological disposal of radioactive waste in fractured crystalline rocks. The current work is focused on the research and experiments in the tunnel located at 500 m depth. The data collected in the tunnel and exploratory boreholes were shared with the participants of the DEvelopment of COupled models and their VALidation against EXperiments (DECOVALEX), an international research and model comparison collaboration. This study describes the development of the fracture model representing granite rocks around the research tunnel. The model domain is 100x150x100m with the main experimental part of the tunnel, Closure Test Drift, located approximately in the center. The major input data were the fracture traces measured on the tunnel walls (total of 2,023 fractures), fractures observed in the horizontal borehole parallel to the tunnel, and the packer tests conducted in this borehole and one vertical borehole located within the modeling domain. 78 fractures (the ones with the inflow) in the tunnel were incorporated in the development of the fracture model. Fracture size was derived from the fracture trace analysis. It was shown that the fracture radius followed lognormal distributions. Fracture transmissivity was estimated from an analytical solution of inflow into the tunnel through an individual fracture and the total measured inflow into the tunnel. 16 fractures were incorporated in the model along the horizontal borehole. The packer test data in the different well intervals were used to estimate the range in fracture transmissivity. A relationship between the fracture transmissivity and fracture radius was developed. The fractures in the tunnel and borehole were used to derive fracture orientation and

  3. FUNCTIONAL RECOVERY AFTER MINIMALLY INVASIVE OSTEOSYNTHESIS IN FRACTURES OF THE SHAFT OF THE RADIUS AND ULNA

    Directory of Open Access Journals (Sweden)

    A. N. Chelnokov

    2016-01-01

    Full Text Available Introduction. Closed intramedullary nailing and external fixation are minimally invasive treatment options in radial and ulnar shaft fractures. We found no comparative studies of these methods in the current literature. Objective. A comparative analysis of both methods in radial and ulnar shaft fractures treated by closed intramedullary nailing and external fixation. Material and methods. 63 patients with forearm shaft fractures treated by closed intramedullary nailing (group I; 24 patients treated by external fixation (group II. All patients were operated within 30 days after injury. Postoperatively, all patients were evaluated clinically (range of motion of elbow and wrist, rotation of the forearm and radiologically. Disability of the Arm, Shoulder and Hand (DASH score was used to assess the functional status and quality of life. Results. The average time of radiological bone union in the group I and group II was 12,6 ± 1,4 weeks. and 12,7 ± 0,6 weeks, accordingly. Statistically significant differences in range of motion in the elbow and wrist occurred in 1 month after the surgery with the advantage in Group I. Restoration of rotation was faster in Group I up to 1 year after surgery. DASH scores in 2 month after the surgery were 11,2±1,96 in the nailing group (as in healthy population and 45,2±6,7 in the external fixation group. In 6 months after surgery the subjective assessment of the quality of life did not differ in both groups. Conclusion. Both minimally invasive methods of surgical stabilization provide restoration of anatomy of the forearm and complete functional recovery in final outcome, but closed intramedullary nailing results with significantly more rapid restoration of range of motions and quality of life measures.

  4. Experimental and numerical study of radial lateral fracturing for coalbed methane

    International Nuclear Information System (INIS)

    Fu, Xuan; Li, Gensheng; Huang, Zhongwei; Liang, Yuesong; Xu, Zhengming; Jin, Xiao

    2015-01-01

    Drilling ultra-short radius horizontal laterals in a vertical well and then operating hydraulic fracturing (radial lateral fracturing, abbreviated as RLF) is proposed as a prospective novel method to increase the single-well productivity for coalbed methane (CBM) development. The objective of this article is to find the best fracture network profile RLF can generate and what kind of formation is suitable for this fracturing technique. Experiments using a true tri-axial fracturing simulation system are designed to analyse the influence of different lateral length, count and azimuth on the fracturing initiation and propagation. A numerical simulation is also carried out to study the sensitivity of the coal integrity and in situ stress state on the fracture initiation type. Our work shows that: the best effect of RLF is achieved when it initiates from the bedding plane where the laterals lie and forms a fracture network with one main horizontal fracture connecting multiple vertical fractures; the breakdown and injection pressure will be decreased by increasing the lateral length and count; increasing the lateral length can enlarge the horizontal fracture area; the optimal lateral design for horizontal initiation is four laterals with the phase of 90° and each lateral is at 45° from the horizontal stress; RLF is suitable for the intact coal seams in which cracks or cleats are not well developed and the overburden stress should be close to or less than the maximum horizontal stress. This paper will provide the experimental support and theoretical bases for CBM RLF design. (paper)

  5. [Operative treatment of sacroiliac joint fracture and dislocation in Tile C pelvic fracture with Colorado 2 system].

    Science.gov (United States)

    Liu, Shuping; Zhou, Qing; Liu, Yuehong; Chen, Xi; Zhou, Yu; Zhang, Desheng; Fang, Zhi; Xu, Wei

    2011-12-01

    To explore the effectiveness of Colorado 2 system in the stability reconstruction of sacroiliac joint fracture and dislocation in Tile C pelvic fracture. Between February 2009 and January 2011, 8 cases of Tile C pelvic fracture were treated with Colorado 2 system. There were 3 males and 5 females with an average age of 34.4 years (range, 22-52 years). Fractures were caused by traffic accident in 3 cases, by falling from height in 3 cases, and by crash of heavy object in 2 cases. According to Tile classification, 5 cases were classified as C1-2, 2 cases as C1-3, and 1 case as C2. The time between injury and operation was 5-10 days (mean, 7 days). After skeletal traction reduction, Colorado 2 system was used to fix sacroiliac joint, and reconstruction plate or external fixation was selectively adopted. The postoperative X-ray films showed that the reduction of vertical and rotatory dislocation was satisfactory, posterior pelvic ring achieved effective stability. All the incisions healed by first intention, and no blood vessel or nerve injury occurred. Eight patients were followed up 6-24 months (mean, 12 months). No loosening or breakage of internal fixation was observed and no re-dislocation of sacroiliac joint occurred. The bone healing time was 6-12 months (mean, 9 months). According to Majeed's functional criterion, the results were excellent in 5 cases, good in 2 cases, and fair in 1 case at last follow-up. Colorado 2 system could provide immediate stability of pelvic posterior ring and good maintenance of reduction effect, which is an effective method in the therapy of sacroiliac joint fracture and dislocation in Tile C pelvic fracture.

  6. Management of fractures of the mandibular body and symphysis.

    Science.gov (United States)

    Goodday, Reginald H B

    2013-11-01

    Mandibular fracture, specifically in the symphysis and body regions combined, is the most common facial fracture requiring hospitalization in North America. The primary treatment objective is to restore form and function by achieving anatomic reduction and placing fixation that eliminates mobility of the bone fragments. Several treatment options and surgical techniques are available for performing closed or open reduction. Special considerations are necessary when treating pediatric patients and fractures of the edentulous mandible. Complications relating to the tooth and denture-bearing regions of the mandible include infection, nonunion, and neurosensory changes. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Forearm diaphyseal fractures in the adolescent population: treatment and management.

    Science.gov (United States)

    Truntzer, Jeremy; Vopat, Matthew L; Kane, Patrick M; Christino, Melissa A; Katarincic, Julia; Vopat, Bryan G

    2015-02-01

    Pediatric both-bone diaphyseal forearm fractures are commonly treated in a variety of clinical settings. Most often, closed reduction followed by immobilization leads to satisfactory results. However, in the adolescent population (10-16 years of age), forearm fractures are more challenging due to less remodeling potential. The purpose of this review was to provide an overview of the anatomy, biomechanics, and treatment options relevant to adolescent patients. A systematic review of peer-reviewed publications and abstracts related to the treatment for pediatric both-bone diaphyseal forearm fractures in adolescents was carried out. Forearm fractures in the pediatric population are most common following indirect blows to the forearm. When treating these fractures using closed reduction, it is important to recognize the muscular attachments of the forearm. In roughly 70-90% of cases, closed reduction leads to adequate alignment. In all cases, return to function is the primary goal; however, exact alignment parameters remain controversial. In the adolescent population, surgical treatment has risen substantially in the last few decades. Intramedullary nailing and open reduction using plate fixation are the two most common operative techniques. Unfortunately, recent results have shown that nonunion, malunion, and overall complication rates are higher in older pediatric patients. Moreover, no consensus exists regarding one technique over another. Both-bone diaphyseal fractures in the adolescent population present unique challenges regarding optimal treatment, especially when considering surgical intervention. Further research is necessary to better understand indications for specific surgical treatment.

  8. Comminuted fracture of the accessory carpal bone removed via an arthroscopic-assisted arthrotomy

    Science.gov (United States)

    Bonilla, Alvaro G.; Santschi, Elizabeth M.

    2015-01-01

    A 16-year-old American paint horse gelding was presented for evaluation of a left forelimb lameness grade III/V. Radiographs and computed tomography revealed a comminuted fracture of the accessory carpal bone involving the entire articulation with the distal radius and the proximal aspect of the articulation with the ulnar carpal bone. Multiple fragments were present in the palmar pouch of the antebrachiocarpal joint. An arthroscopic-assisted open approach was necessary to remove all fractured fragments. Subsequently the horse was re-admitted for lameness and was treated successfully with antibiotics and long-term supportive bandaging. PMID:25694665

  9. Comminuted fracture of the accessory carpal bone removed via an arthroscopic-assisted arthrotomy.

    Science.gov (United States)

    Bonilla, Alvaro G; Santschi, Elizabeth M

    2015-02-01

    A 16-year-old American paint horse gelding was presented for evaluation of a left forelimb lameness grade III/V. Radiographs and computed tomography revealed a comminuted fracture of the accessory carpal bone involving the entire articulation with the distal radius and the proximal aspect of the articulation with the ulnar carpal bone. Multiple fragments were present in the palmar pouch of the antebrachiocarpal joint. An arthroscopic-assisted open approach was necessary to remove all fractured fragments. Subsequently the horse was re-admitted for lameness and was treated successfully with antibiotics and long-term supportive bandaging.

  10. Investigation on the Productivity Behaviour in Deformable Heterogeneous Fractured Reservoirs

    DEFF Research Database (Denmark)

    Kadeethum, Teeratorn; Salimzadeh, Saeed; Nick, Hamid

    reasons for this reduction. Discrete fracture and matrix (DFM) modelling is selected in this investigation because of its ability to represent fracture behaviours more realistically. Moreover, it has become a preferential method for modelling flow in fractured formations for the past decade (Bisdom et al...

  11. Field assessment of the use of borehole pressure transients to measure the permeability of fractured rock masses

    International Nuclear Information System (INIS)

    Forster, C.B.; Gale, J.E.

    1981-06-01

    A field experiment to evaluate the transient pressure pulse technique as a method of determining the in-situ hydraulic conductivity of low permeability fractured rock was made. The experiment attempted to define: the radius of influence of a pressure pulse-test in fractured rock and the correlation between pressure-pulse tests and steady-state flow tests performed in five boreholes drilled in fractured granite. Twenty-five test intervals, 2 to 3 m in length, were isolated in the boreholes, using air-inflated packers. During pressure pulse and steady-state tests, pressures were monitored in both the test and observation cavities. Rock-mass conductivities were calculated from steady-state test results and were found to range from less than 10 - 11 to 10 - 7 cm/sec. However, there was no consistent correlation between the steady-state conductivity and the pressure pulse decay characteristics of individual intervals. These conflicting test results can be attributed to the following factors: differences in volumes of rock affected by the test techniques; effects of equipment configuration and compliance; and complexity of the fracture network. Although the steady-state flow tests indicate that hydraulic connections exist between most of the test cavities, no pressure responses were noted in the observation cavities (located at least 0.3 m from the test cavities) during the pulse tests. This does not mean, however, that the pressure-pulse radius of influence is <0.3 m, because the observation cavities were too large (about 7 liters). The lack of correlation between steady-state conductivities and the corresponding pressure pulse decay times does not permit use of existing single-fracture type curves to analyze pulse tests performed in multiple-fracture intervals. Subsequent work should focus on the detailed interpretation of field results with particular reference to the effects of the fracture system at the test site

  12. Surgical repair of mid-body proximal sesamoid bone fractures in 25 horses.

    Science.gov (United States)

    Busschers, Evita; Richardson, Dean W; Hogan, Patricia M; Leitch, Midge

    2008-12-01

    To describe the characteristics of unilateral mid-body proximal sesamoid bone (PSB) fractures, to determine factors associated with the outcome of horses after surgical repair, and to describe a technique for arthroscopically assisted screw fixation in lag fashion. Retrospective case series. Horses (n=25) with unilateral mid-body PSB fracture. Medical records (1996-2006), radiographs, and arthroscopic videos of horses with surgically repaired unilateral mid-body PSB fractures were reviewed. Retrieved data included signalment, affected limb and PSB, fracture characteristics, and surgical technique. Outcome was established by radiographic assessment of healing and race records; categorical data were analyzed using Fisher's Exact test. Medial forelimb PSBs were most commonly affected (80%). Surgical technique and degree of reduction were significantly associated with outcome; 44% of horses with screw repair and none of the horses with wire fixation raced (P=.047). Factors that may have influenced this outcome were differences in fracture reduction (improved reduction in 22% wire repairs and 88% screw repairs, P=.002) and use of external coaptation (22% wire repair and 88% lag screw repair, P=.002). None of the horses with unimproved reduction raced after surgery. Only 28% of horses with mid-body PSB fractures raced after surgery. Compared with wire fixation, screw fixation in lag fashion resulted in good reduction and is seemingly a superior repair technique. For mid-body PSB fractures, arthroscopically assisted screw fixation in lag fashion and external coaptation for anesthesia recovery and initial support provides the best likelihood of return to athletic use.

  13. Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation.

    Science.gov (United States)

    De Giacomo, Anthony F; Tornetta, Paul

    2016-10-01

    To evaluate the efficacy of intramedullary nailing of distal tibia fractures using modern techniques, without fibula fixation, in obtaining and maintaining alignment. Retrospective case review. Level-I academic trauma center. One hundred thirty-two consecutive patients with distal tibia fractures. Intramedullary nail of distal tibia fracture, without fibula fixation, was performed in consecutive patients using modern reduction techniques. Malalignment and malunion were defined as >5 degrees of varus/valgus angulation or anterior/posterior angulation on the initial postoperative or final anteroposterior and lateral x-rays. There were 122 consecutive patients (86 men and 36 women) 16-93 years of age (average, 43 years) with 36 (30%) open and 85 (70%) closed fractures with complete follow-up. Mechanism of injury did not predict the presence or level of fibula fracture. Upon presentation, varus/valgus and procurvatum/recurvatum angulation was greatest when the fibula was fractured at the level of the tibia fracture (P = 0.001 and 0.028). The most common intraoperative reduction aids were nailing in relative extension, transfixion external fixation, and clamps at the fracture site. The OTA fracture type or level/presence of fibula fracture did not influence malalignment (P = 0.86 and 0.66), malunion (P = 0.81 and 0.79), or the change in alignment during union, which averaged 0.9 degrees. We found an overall low rate of both malalignment (2%) and malunion (3%) after intramedullary nailing of distal tibial shaft fracture without fibula fixation. We conclude that when modern nailing techniques are used, which allow for confirmation of reduction by visualization in fluoroscopy, from nail placement to distal interlocking, fibula fixation is not necessary to obtain or maintain alignment. Furthermore, standard 2 medial to lateral screws distally afford adequate stability to hold the reduction during union with a 0.9-degree difference in the initial postoperative and final

  14. Pediatric mandibular fractures: a free hand technique.

    Science.gov (United States)

    Davison, S P; Clifton, M S; Davison, M N; Hedrick, M; Sotereanos, G

    2001-01-01

    The treatment of pediatric mandibular fractures is rare, controversial, and complicated by mixed dentition. To determine if open mandibular fracture repair with intraoral and extraoral rigid plate placement, after free hand occlusal and bone reduction, without intermaxillary fixation (IMF), is appropriate and to discuss postoperative advantages, namely, maximal early return of function and minimal oral hygiene issues. A group of 29 pediatric patients with a mandibular fracture were examined. Twenty pediatric patients (13 males and 7 females) with a mean age of 9 years (age range, 1-17 years) were treated using IMF. All patients were treated by the same surgeon (G.S.). Surgical time for plating was reduced by 1 hour, the average time to place patients in IMF. The patients who underwent open reduction internal fixation without IMF ate a soft mechanical diet by postoperative day 3 compared with postoperative day 16 for those who underwent IMF. Complication rates related to fixation technique were comparable at 20% for those who did not undergo IMF and 33% for those who did. We believe that free hand reduction is a valuable technique to reduce operative time for pediatric mandibular fractures. It maximizes return to function while minimizing the oral hygiene issues and hardware removal of intermaxillary function.

  15. Ulnar nerve paralysis after forearm bone fracture

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    2016-08-01

    Full Text Available ABSTRACT Paralysis or nerve injury associated with fractures of forearm bones fracture is rare and is more common in exposed fractures with large soft-tissue injuries. Ulnar nerve paralysis is a rare condition associated with closed fractures of the forearm. In most cases, the cause of paralysis is nerve contusion, which evolves with neuropraxia. However, nerve lacerations and entrapment at the fracture site always need to be borne in mind. This becomes more important when neuropraxia appears or worsens after reduction of a closed fracture of the forearm has been completed. The importance of diagnosing this injury and differentiating its features lies in the fact that, depending on the type of lesion, different types of management will be chosen.

  16. A Maximum Radius for Habitable Planets.

    Science.gov (United States)

    Alibert, Yann

    2015-09-01

    We compute the maximum radius a planet can have in order to fulfill two constraints that are likely necessary conditions for habitability: 1- surface temperature and pressure compatible with the existence of liquid water, and 2- no ice layer at the bottom of a putative global ocean, that would prevent the operation of the geologic carbon cycle to operate. We demonstrate that, above a given radius, these two constraints cannot be met: in the Super-Earth mass range (1-12 Mearth), the overall maximum that a planet can have varies between 1.8 and 2.3 Rearth. This radius is reduced when considering planets with higher Fe/Si ratios, and taking into account irradiation effects on the structure of the gas envelope.

  17. Surgical Stabilization of Pelvic and Acetabular Fractures: A Review on the Determinants of Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    SS Sathappan

    2010-03-01

    Full Text Available AIM: Pelvic and acetabular fractures are associated with high-energy trauma. The aim of this study was to identify factors that are associated with specific clinical outcomes following treatment for these fractures. METHODS: A consecutive series of 30 patients who had surgical intervention for either pelvic or acetabular fractures formed the sample for this study. Clinical variables reviewed were: age, associated injuries, number of surgical procedures, time to surgery and post-operative complications. Clinical outcomes were assessed using Matta’s grading of post- operative fracture reduction alignment, and functional outcomes were graded using D'Aubigne & Postel’s Hip scoring system. RESULTS: Study subjects included twelve pelvic fractures and eighteen acetabular fractures. Patients older than 50 years of age had poorer hip scores despite surgery. Earlier fracture fixation (within five days was associated with better hip scores. Patients with acetabular fractures generally had better functional outcomes than patients with pelvic fractures (mean hip score 15.0 vs. 13.5. Closer anatomical reduction of acetabular fractures was associated with better functional outcome. CONCLUSION: Improved clinical outcomes are associated with younger age, fewer concomitant injuries, shorter time interval to surgery and more closely approximated anatomical fracture reduction.

  18. Treatment of displaced mandibular condylar fracture with botulinum toxin A.

    Science.gov (United States)

    Akbay, Ercan; Cevik, Cengiz; Damlar, Ibrahim; Altan, Ahmet

    2014-04-01

    The aim of this case report is to discuss the effect on condylar reduction of botulinum toxin A treatment used in a child with displaced fracture at condylar neck of mandible. A 3-years old boy was admitted to our clinic for incomplete fracture of mandibular symphysis and displaced condylar fracture at the left side. An asymmetrical occlusal splint with intermaxillary fixation was used instead of open reduction and internal fixation because of incomplete fracture of symphysis and possible complications of condyle surgery. However, it was observed that condylar angulation persisted despite this procedure. Thus, botulinum toxin A was administered to masseter, temporalis and pterygoideus medialis muscles. At the end of first month, it was seen that mandibular condyle was almost completely recovered and that fusion was achieved. In conclusion, Botulinum A toxin injection aiming the suppression of masticatory muscle strength facilitates the reduction in the conservative management of displaced condyle in pediatric patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Periprosthetic fractures around the knee-the best way of treatment

    DEFF Research Database (Denmark)

    Ruchholtz, Steffen; Tomás, Jordi; Gebhard, Florian

    2013-01-01

    A variety of methods has been described to stabilise periprosthetic fractures around total knee arthroplasty (TKA). Our report offers a review of the actual strategies in the reduction and fixation of these fractures. Surgical treatment should be based on the following four steps......:Diagnostics: By taking the patients' history together with an X-ray of the knee and femur, the fracture is analysed. It is crucial to define whether any losening of the prosthesis had occurred. In selected cases, CT-scan may add important information on the stability of the implant.Classification and planning: For most...... fractures around the distal femur, the Rorabeck classification is used while fractures around the proximal tibia are best classified according to the Felix classification. Additionally the Orthopaedic Trauma Association (OTA) may be helpful in the planning process for reduction and fixation...

  20. Crack retardation by load reduction during fatigue crack propagation

    International Nuclear Information System (INIS)

    Kim, Hyun Soo; Nam, Ki Woo; Ahn, Seok Hwan; Do, Jae Yoon

    2003-01-01

    Fracture life and crack retardation behavior were examined experimentally using CT specimens of aluminum alloy 5083. Crack retardation life and fracture life were a wide difference between 0.8 and 0.6 in proportion to ratio of load reduction. The wheeler model retardation parameter was used successfully to predict crack growth behavior. By using a crack propagation rule, prediction of fracture life can be evaluated quantitatively. A statistical approach based on Weibull distribution was applied to the test data to evaluate the dispersion in the retardation life and fracture life by the change of load reduction

  1. Intra-articular Entrapment of Medial Epicondyle Fracture Fragment in Elbow Joint Dislocation Causing Ulnar Neuropraxia: A Case Report

    Directory of Open Access Journals (Sweden)

    Syed J

    2017-03-01

    Full Text Available Traumatic elbow dislocations in children are rare but most of them are complex dislocations, and in such dislocations, medial humerus epicondyle fractureis the most common associated injury. Fracture incarceration in the elbow joint occurs in 5-18% of medial humerus epicondyle fractures but ulnar neuropraxia is very rare. Open reduction internal fixation is indicated in medial humerus epicondyle fracture with fracture incarceration, ulnar neuropraxia, marked instability or open fracture. Operative treatment options include fragment excision and sutures, closed or open reduction and Kirschner wire fixation, open reduction and suture fixation, open reduction and smooth pin fixation, and open reduction and screw fixation. However, ulnar nerve transposition is debatable as good outcome had been reported with and without nerve transposition. We report a case of a 13-year old boy, who presented with right elbow dislocation and intra-articular entrapment of medial humerus epicondyle fracture fragment, complicated with sensory ulnar neuropraxia, following a fall onto his right outstretched hand in a motor vehicle accident. The elbow joint was reduced using close manipulative reduction but the fracture fragment remained entrapped post-reduction. The patient then underwent open reduction and screw fixation of the medial humerus epicondyle fracture without ulnar nerve transposition. He had good functional outcome six weeks after surgical intervention, with complete recovery of ulnar neuropraxia six months later. Currently, he is doing well at school and is active with his sporting activity.

  2. Isolated Fracture of the Coracoid Process

    Directory of Open Access Journals (Sweden)

    Ali Güleç

    2014-01-01

    Full Text Available Coracoid fractures are rarely seen fractures. In the shoulder girdle, coracoid process fractures generally accompany dislocation of the acromioclavicular joint or glenohumeral joint, scapula corpus, clavicula, humerus fracture, or rotator cuff tear. Coracoid fractures can be missed and the treatment for coracoid process fractures is still controversial. In this paper, a 34-year-old male manual labourer presented to the emergency department with complaints of pain and restricted movement in the left shoulder following a traffic accident. On direct radiographs and computerised tomography images a fragmented fracture was observed on the base of the coracoid process. In addition to the coracoid fracture, a mandibular fracture was determined. The patient was admitted for surgery on both fractures. After open reduction, fixation was made with a 3.5 mm cannulated screw and washer. At the postoperative 6th week, bone union was determined. The patient returned to his previous occupation pain-free and with a full range of joint movement. In conclusion, in the current case of isolated fragmented coracoid process fracture showing minimal displacement in a patient engaged in heavy manual work, surgery was preferred as it was thought that nonunion might be encountered particularly because of the effect of forces around the coracoid.

  3. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study.

    Science.gov (United States)

    Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed

    2016-10-01

    Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  4. Low volumetric BMD is linked to upper-limb fracture in pubertal girls and persists into adulthood: a seven-year cohort study.

    Science.gov (United States)

    Cheng, Sulin; Xu, Leiting; Nicholson, Patrick H F; Tylavsky, Frances; Lyytikäinen, Arja; Wang, Qingju; Suominen, Harri; Kujala, Urho M; Kröger, Heikki; Alen, Markku

    2009-09-01

    The aetiology of increased incidence of fracture during puberty is unclear. This study aimed to determine whether low volumetric bone mineral density (vBMD) in the distal radius is associated with upper-limb fractures in growing girls, and whether any such vBMD deficit persists into adulthood. Fracture history from birth to 20 years was obtained and verified by medical records in 1034 Finnish girls aged 10-13 years. Bone density and geometry at distal radius, biomarkers and lifestyle/behavioural factors were assessed in a subset of 396 girls with a 7.5-year follow-up. We found that fracture incidence peaked during puberty (relative risk 3.1 at age of 8-14 years compared to outside this age window), and 38% of fractures were in the upper-limb. Compared to the non-fracture cohort, girls who sustained upper-limb fracture at ages 8-14 years had lower distal radial vBMD at baseline (258.9+/-37.5 vs. 287.5+/-34.1 mg/cm(3), p=0.001), 1-year (252.0+/-29.3 vs. 282.6+/-33.5 mg/cm(3), p=0.001), 2-year (258.9+/-32.2 vs. 289.9+/-40.1 mg/cm(3), p=0.003), and 7-year follow-ups (early adulthood, 307.6+/-35.9 vs. 343.6+/-40.9 mg/cm(3), p=0.002). There was a consistent trend towards larger bone cross-sectional area in the fracture cohort compared to non-fracture. In a logistic regression model, lower vBMD (p=0.001) was the only significant predictor of upper-limb fracture during the period of 8-14 years. Our results indicate that low BMD is an important factor underlying elevated upper-limb fracture risk during puberty, and that low BMD in pubertal girls with fracture persists into adulthood. Hence low vBMD during childhood is not a transient deficit. Methods to monitor vBMD and to maximise bone mineral accrual and reduce risks of falling in childhood should be developed.

  5. [Posterior partial trochanteric osteotomy for the treatment of the roof involved acetabular fractures].

    Science.gov (United States)

    Wang, Pan-Feng; Xu, Shuo-Gui; Zhang, Chun-Cai; Fu, Qing-Ge; Zhang, Yun-Tong; Liu, Xin-Wei; Niu, Yun-Fei; Tang, Yang

    2013-11-01

    To introduce a new trochanteric osteotomy,and evaluate the outcome of the procedure combined a posterior lateral approach in treating acetabular fractures which involving the roof. Between March 2007 and Novmber 2010,30 patients with displaced acetabular fractures involving the dome need trochanteric osteotomy were retrospectively reviewed. There were 21 males and 9 females,ranging in age from 18 to 70 years with an average of 35.2 years at the time of injury. According to Letournel-Judet classification, there were 10 posterior wall fractures,7 posterior column fractures,5 transverse fractures, 2 T-shape fractures, 1 transverse associated with posterior wall fracture, 3 posterior column and wall fractures and 2 bicolumn fractures. The standards of Matta,the modified Merle d'Aubigne-Postel, Medical Research Council were respectively used to evaluate the reduction result, function of hip joint and the strength of hip abduction. All patients were followed up with an average time of 25 months (18 to 40) and all osteotomy sites obtained bone union with an average time of 8.4 weeks (6 to 12). No bone non-union, bone block displaceing, internal fixation looseing and breaking,infection of deep part were found. Seventeen patients got anatomic reduction, 12 got satisfied reduction, and 1 got unsatisfied result according to the criteria of Matta. At final follow-up, function of hip joint obtained excellent results in 11 cases, good in 15, fair in 3 and poor in 1. The strength of the abductors of 3 patients were grade 4 and 27 patients were grade 5. Posterior partial great trochanteric osteotomy can enhance the exposure and provide a more accurate reduction and degrade the difficulty of acetabular fracture fixation without increasing the risk of complications. The method provide a new way for the treatment of the roof involved acetabular fractures.

  6. The treatment of subtrochanteric fractures

    Directory of Open Access Journals (Sweden)

    Vučetić Čedomir S.

    2011-01-01

    Full Text Available Subtrochanteric fractures of the femur have a special place because of a significant number of complications following treatment. Powerful loading forces asymmetrically acting to this bone segment, as well as poor vascularization interfere with bone union. There are basically two current approaches in the fixation of subtrochanteric fractures; the first involves a plate with a compression screw and another one is intramedullary (IM nail, with two options: centromedullary (standard interlocking femoral nail and cephalomedullary femoral nail with two modifications, reconstructive and trochanteric. All IM nails may be used by open technique or closed minimal invasive method. IM nailing is favoured in view of a shorter operative time, shorter hospitalisation and complications. Indirect fracture reduction and knowledge of biology of bone fracture may result in full success without any bone graft.

  7. Evidence-based medicine: Mandible fractures.

    Science.gov (United States)

    Morrow, Brad T; Samson, Thomas D; Schubert, Warren; Mackay, Donald R

    2014-12-01

    After studying this article, the participant should be able to: 1. Describe the anatomy and subunits of the mandible. 2. Review the cause and epidemiology of mandible fractures. 3. Discuss the preoperative evaluation and diagnostic imaging. 4. Understand the principles and techniques of mandible fracture reduction and fixation. The management of mandibular fractures has undergone significant improvement because of advancements in plating technology, imaging, and instrumentation. As the techniques in management continue to evolve, it is imperative for the practicing physician to remain up-to-date with the growing body of scientific literature. The objective of this Maintenance of Certification article is to present a review of the literature so that the physician may make treatment recommendation based on the best evidence available. Pediatric fractures have been excluded from this article.

  8. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation.

    Science.gov (United States)

    Simon, A-L; Apostolou, N; Vidal, C; Ferrero, E; Mazda, K; Ilharreborde, B

    2018-02-01

    Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. IV.

  9. Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    Science.gov (United States)

    Kern, Andrew M; Anderson, Donald D

    2015-09-18

    Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promising agreement with PTOA development was seen, the inherent complexities of contact FEA limited the numbers of subjects that could be analyzed. Discrete element analysis (DEA) is a simplified methodology for contact stress computation, which idealizes contact surfaces as a bed of independent linear springs. In this study, DEA was explored as an expedited alternative to FEA contact stress exposure computation. DEA was compared to FEA using results from a previously completed validation study of two cadaveric human ankles, as well as a previous study of post-operative contact stress exposure in 11 patients with tibial plafond fracture. DEA-computed maximum contact stresses were within 19% of those experimentally measured, with 90% of the contact area having computed contact stress values within 1MPa of those measured. In the 11 fractured ankles, maximum contact stress and contact area differences between DEA and FEA were 0.85 ± 0.64 MPa and 22.5 ± 11.5mm(2). As a predictive measure for PTOA development, both DEA and FEA had 100% concordance with presence of OA (KL grade ≥ 2) and >95% concordance with KL grade at 2 years. These results support DEA as a reasonable alternative to FEA for computing contact stress exposures following surgical reduction of a tibial plafond fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  11. Tracer dispersion in two-dimensional rough fractures.

    Science.gov (United States)

    Drazer, G; Koplik, J

    2001-05-01

    Tracer diffusion and hydrodynamic dispersion in two-dimensional fractures with self-affine roughness are studied by analytic and numerical methods. Numerical simulations were performed via the lattice-Boltzmann approach, using a boundary condition for tracer particles that improves the accuracy of the method. The reduction in the diffusive transport, due to the fractal geometry of the fracture surfaces, is analyzed for different fracture apertures. In the limit of small aperture fluctuations we derive the correction to the diffusive coefficient in terms of the tortuosity, which accounts for the irregular geometry of the fractures. Dispersion is studied when the two fracture surfaces are simply displaced normally to the mean fracture plane and when there is a lateral shift as well. Numerical results are analyzed using the Lambda parameter, related to convective transport within the fracture, and simple arguments based on lubrication approximation. At very low Péclet number, in the case where fracture surfaces are laterally shifted, we show using several different methods that convective transport reduces dispersion.

  12. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    International Nuclear Information System (INIS)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E.

    1992-01-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author)

  13. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    Energy Technology Data Exchange (ETDEWEB)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E. (Ankara Social Security Hospital (Turkey))

    1992-08-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author).

  14. Long term surgical treatment outcome of talar body fracture

    Directory of Open Access Journals (Sweden)

    Sen Ramesh Kumar

    2012-02-01

    Full Text Available 【Abstract】Objective: Talar body fractures are rare and have poor treatment outcome. The purpose of this study is to report the long term surgical treatment outcome of closed talar dome fractures. Methods: Eight closed talar body fractures, treated by open reduction and internal fixation with small fragment cancellous screws and/or Herbert screws in our level I trauma centre were retrospectively analyzed. Preoperative and postoperative radiographs of the foot (antero-posterior, lateral and oblique views and ankle (antero-posterior, lateral and mortise views were obtained. The patients were followed up both radiologically and functionally (foot function index, FFI after 3 weeks, 6 weeks, 3 months, 6 months and then annually. Results: There were five crush fractures and three shear fractures (two sagittal shear and one coronal shear, with average follow-up of 5 years. No early complications were noticed in these patients. Late complications included osteoarthrosis of subtalar/ankle joints in six patients and osteonecrosis of talar body in four patients. On functional assessment, mean FFI after 5 years was 104.63 points and worse outcome was noticed in crush injury and coronal shear fractures. Sagittal shear fractures had a good functional and radiological outcome. Conclusions: Late complications subsequent to surgically treated talar body fractures are inevitable, even though exact reduction and rigid fixation are achieved, thus patients are supposed to be counseled about the adverse outcome. Although crush and coronal shear fractures have poor outcome, sagittal injuries have good prognosis on long term evaluation. Key words: Fractures, bone; Talus; Fracture fixation, internal

  15. Effect of helium bubbles at grain boundaries on the fracture characteristics of high-density 238PuO2

    International Nuclear Information System (INIS)

    Sisson, R.D.; McDonell, W.R.

    1976-01-01

    Helium bubbles that formed at grain boundaries in high density (greater than 92 percent of theoretical) 238 PuO 2 shards did not affect the room temperature fracture behavior as observed by scanning electron microscopy. Fracture was predominantly by brittle transgranular cleavage with only infrequent intergranular failure observed. Pores (approximately 5 μm dia) that formed within the grains during the sintering process, rather than helium bubbles, initiated fractures. Helium bubbles were observed occasionally on the fracture surfaces of 20-month-old shards that had been heated to 1600 0 C for 8 h and subsequently crushed at room temperature. The average radius of these bubbles was approximately 1 μm. These bubbles were not interconnected, but were sometimes aligned in stringers

  16. Epidemiological analysis of mandibular fractures treated in Sao Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Kelly Marinho

    2015-10-01

    Conclusion: The treatment of mandibular fractures should be aimed at restoring the occlusion and mastication function, with surgery being the most indicated treatment, using reduction and internal fixation with the use of a plates and screws system based on the experience of the authors. Knowledge of surgical techniques and methods of reduction and fixation of fractures, and periodic monitoring allow these patients to receive the appropriate treatment.

  17. Operative Versus Conservative Management of Displaced Tibial Shaft Fracture in Adolescents.

    Science.gov (United States)

    Kinney, Matthew C; Nagle, David; Bastrom, Tracey; Linn, Michael S; Schwartz, Alexandra K; Pennock, Andrew T

    2016-01-01

    Displaced tibial shaft fractures are common in adolescent patients, yet there is no standardized management strategy. We compared surgical fixation and closed reduction and casting (CRC) of these fractures to assess treatment outcomes and determine predictors of failure. We retrospectively reviewed all patients aged 12 to 18 who presented with a displaced tibial shaft fracture that required reduction over an 8-year period. Exclusion criteria included open fractures and lack of follow-up to radiographic union or to 6 months from the index procedure. Fractures were initially treated based on surgeon preference either with CRC or with immediate intramedullary nailing. Seventy-four patients met inclusion criteria: 57 were initially managed with CRC and 17 with operative fixation. Radiographic healing was defined as bridging of 3 cortices and adequacy of final alignment was defined as 20% (odds ratio=7.8, Palignment (92.5% vs. 72.4%, P=0.10) but required longer hospitalization (5.4 vs. 1.9 d, P<0.001) and had a higher incidence of anterior knee pain (20% vs. 0%, P<0.01). There was no significant difference between groups with respect to time to healing. Treatment outcomes between initial operative fixation and closed reduction of displaced tibia fractures in adolescents are similar, but patients must be counseled about the high failure rates with CRC. Predictors of CRC failure include initial fracture displacement and the presence of a fibula fracture-these variables should be considered when selecting a treatment method. Level III-Therapeutic study.

  18. Low levels of 25-hydroxyvitamin D are associated with the occurrence of concomitant upper limb fractures in older women who sustain a fall-related fracture of the hip.

    Science.gov (United States)

    Di Monaco, Marco; Vallero, Fulvia; Castiglioni, Carlotta; Di Monaco, Roberto; Tappero, Rosa

    2011-01-01

    To investigate the association between serum levels of 25-hydroxyvitamin D and the occurrence of simultaneous fractures of the upper limb in older women who sustain a fall-related fracture of the hip. Cross-sectional study. We investigated 472 of 480 white women consecutively admitted to a rehabilitation hospital because of a fall-related hip fracture. Twenty-seven (5.7%) of the 472 women sustained a concomitant upper-limb fracture of either distal radius (20 women) or proximal humerus (seven women). We assessed serum levels of 25-hydroxyvitamin D 14.2 ± 4.1 (mean ± SD) days after surgical repair of the hip fracture in the 472 women by an immunoenzymatic assay. Twenty-five-hydroxyvitamin D levels were significantly lower in the 27 women with concomitant fractures of both hip and upper limb than in the remaining 445 hip-fracture women: mean ± SD values were 6.5 ± 5.0 ng/ml and 11.7 ± 10.4 ng/ml respectively in the two groups (mean difference between groups 5.2 ng/ml: 95% CI 1.2-9.2; p=0.011). Low levels of 25-hydroxyvitamin D were significantly associated with concomitant fractures of the upper limb (p=0.017), after adjustment for eight potential confounders including age, height, weight, hip-fracture type, cognitive impairment, neurologic impairment, previous hip fracture, and previous upper-limb fracture. Low levels of 25-hydroxyvitamin D were significantly associated with concomitant upper-limb fractures in our sample of older women with a fall-related fracture of the hip. Preventing vitamin D deficiency may lower the incidence of simultaneous fractures due to a singe fall in elderly women. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Finite-Larmor-radius stability theory of EBT plasmas

    International Nuclear Information System (INIS)

    Berk, H.L.; Cheng, C.Z.; Rosenbluth, M.N.; Van Dam, J.W.

    1982-11-01

    An eikonal ballooning-mode formalism is developed to describe curvature-driven modes of hot electron plasmas in bumpy tori. The formalism treats frequencies comparable to the ion-cyclotron frequency, as well as arbitrary finite Larmor radius and field polarization, although the detailed analysis is restricted to E/sub parallel/ = 0. Moderate hot-electron finite-Larmor-radius effects are found to lower the background beta core limit, whereas strong finite-Lamor-radius effects produce stabilization

  20. Fracture toughness of irradiated beryllium

    International Nuclear Information System (INIS)

    Beeston, J.M.

    1978-01-01

    The fracture toughness of nuclear grade hot-pressed beryllium upon irradiation to fluences of 3.5 to 5.0 x 10 21 n/cm 2 , E greater than 1 MeV, was determined. Procedures and data relating to a round-robin test contributing to a standard ASTM method for unirradiated beryllium are discussed in connection with the testing of irradiated specimens. A porous grade of beryllium was also irradiated and tested, thereby enabling some discrimination between the models for describing the fracture toughness behavior of porous beryllium. The fracture toughness of unirradiated 2 percent BeO nuclear grade beryllium was 12.0 MPa m/sup 1 / 2 /, which was reduced 60 percent upon irradiation at 339 K and testing at 295 K. The fracture toughness of a porous grade of beryllium was 13.1 MPa m/sup 1 / 2 /, which was reduced 68 percent upon irradiation and testing at the same conditions. Reasons for the reduction in fracture toughness upon irradiation are discussed

  1. Is Fibular Fracture Displacement Consistent with Tibiotalar Displacement?

    NARCIS (Netherlands)

    van den Bekerom, Michel P. J.; van Dijk, C. Niek

    2010-01-01

    We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle

  2. Triplane fracture of the distal tibial epiphysis: radiographic and CT studies

    International Nuclear Information System (INIS)

    Cone, R.O. III; Nguyen, V.; Flournoy, J.G.; Guerra, J. Jr.

    1984-01-01

    The authors analyzed six cases of triplane fracture of the ankle and reviewed the literature. A previously underscribed fracture pattern was identified in one patient. CT studies proved to be useful diagnostic tools in the evaluation of triplane fractures when operative reduction was contemplated

  3. Once-yearly zoledronic acid in hip fracture prevention

    Science.gov (United States)

    Demontiero, Oddom; Duque, Gustavo

    2009-01-01

    Osteoporosis is an escalating global problem. Hip fractures, the most catastrophic complication of osteoporosis, continue to cause significant mortality and morbidity despite increasing availability of effective preventative agents. Among these agents, oral bisphosphonates have been the first choice for the treatment and prevention of osteoporotic fractures. However, the use of oral bisphosphonates, especially in the older population, has been limited by their side effects and method of administration thus compromising their persistent use. The resultant low adherence by patients has undermined their full potential and has been associated with an increase in the incidence of fragility fractures. Recently, annual intravenous zoledronic acid (ZOL) has been approved for osteoporosis. Randomized controlled trials have demonstrated ZOL to be safe, have good tolerability and produce significant effect on bone mass and microarchitecture. Adherence has also been shown to be better with ZOL. Furthermore two large trials firmly demonstrated significant anti-osteoporotic effect (∼59% relative risk reduction of hip fractures) and mortality benefit (28% reduction in mortality) of ZOL in older persons with recent hip fractures. In this review, we report the current evidence on the use of ZOL for the prevention of hip fractures in the elderly. We also report the pharmacological characteristics and the advantages and disadvantages of ZOL in this particular group. PMID:19503777

  4. Frictional stability-permeability relationships for fractures in shales

    Science.gov (United States)

    Fang, Yi; Elsworth, Derek; Wang, Chaoyi; Ishibashi, Takuya; Fitts, Jeffrey P.

    2017-03-01

    There is wide concern that fluid injection in the subsurface, such as for the stimulation of shale reservoirs or for geological CO2 sequestration (GCS), has the potential to induce seismicity that may change reservoir permeability due to fault slip. However, the impact of induced seismicity on fracture permeability evolution remains unclear due to the spectrum of modes of fault reactivation (e.g., stable versus unstable). As seismicity is controlled by the frictional response of fractures, we explore friction-stability-permeability relationships through the concurrent measurement of frictional and hydraulic properties of artificial fractures in Green River shale (GRS) and Opalinus shale (OPS). We observe that carbonate-rich GRS shows higher frictional strength but weak neutral frictional stability. The GRS fracture permeability declines during shearing while an increased sliding velocity reduces the rate of permeability decline. By comparison, the phyllosilicate-rich OPS has lower friction and strong stability while the fracture permeability is reduced due to the swelling behavior that dominates over the shearing induced permeability reduction. Hence, we conclude that the friction-stability-permeability relationship of a fracture is largely controlled by mineral composition and that shale mineral compositions with strong frictional stability may be particularly subject to permanent permeability reduction during fluid infiltration.

  5. Fresh fractures of the scaphoid : A rationale method of treatment

    Directory of Open Access Journals (Sweden)

    Chari P

    2006-01-01

    Full Text Available Background : Scaphoid, among all carpal bones, is very vulnerable for fracture due to its unique shape and situation with greater articular surface. All scaphoid fractures are being treated with below elbow POP thumb spica casts keeping hand in ball throwing position. A few scaphoid fractures through the waist take longer time to unite, if not end in nonunion. These fractures were found to be displaced unimpacted trans-scaphoid fractures through the waist. Method : The effect of various positions of hand, wrist and forearm over unimpacted displaced scaphoid fractures through the waist were studied on dissected hand specimens and in patients with skiagrams. It was observed that possible radial deviation of hand over neutrally held wrist and forearm would result in anatomical reduction with impaction between the fragments. Added compression effect at site of fracture, necessary for early fracture healing, is produced by passively abducting the first metacarpal bone. Results : Of 68 scaphoid fractures under study, 24 and 41 were displaced and undisplaced ones through the waist respectively. All of them united in eight to ten weeks time as any fracture, when immobilised undisturbed with anatomic reduction and added compression between the fragments except one displaced fracture which took eight more weeks of immobilization for union and revascularilization of proximal fragment. Conclusion : This study showed that all scaphoid fractures in particular those through waist when rigidly immobilized unite as any fracture in eight to ten weeks provided the proximal fragment maintains proper blood supply. Otherwise it would further eight week of immobilization for the proximal fragment to get revascularize following union.

  6. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    Science.gov (United States)

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  7. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Rib fractures predict incident limb fractures: results from the European prospective osteoporosis study.

    Science.gov (United States)

    Ismail, A A; Silman, A J; Reeve, J; Kaptoge, S; O'Neill, T W

    2006-01-01

    Population studies suggest that rib fractures are associated with a reduction in bone mass. While much is known about the predictive risk of hip, spine and distal forearm fracture on the risk of future fracture, little is known about the impact of rib fracture. The aim of this study was to determine whether a recalled history of rib fracture was associated with an increased risk of future limb fracture. Men and women aged 50 years and over were recruited from population registers in 31 European centres for participation in a screening survey of osteoporosis (European Prospective Osteoporosis Study). Subjects were invited to complete an interviewer-administered questionnaire that included questions about previous fractures including rib fracture, the age of their first fracture and also the level of trauma. Lateral spine radiographs were performed and the presence of vertebral deformity was determined morphometrically. Following the baseline survey, subjects were followed prospectively by annual postal questionnaire to determine the occurrence of clinical fractures. The subjects included 6,344 men, with a mean age of 64.2 years, and 6,788 women, with a mean age of 63.6 years, who were followed for a median of 3 years (range 0.4-5.9 years), of whom 135 men (2.3%) and 101 women (1.6%) reported a previous low trauma rib fracture. In total, 138 men and 391 women sustained a limb fracture during follow-up. In women, after age adjustment, those with a recalled history of low trauma rib fracture had an increased risk of sustaining 'any' limb fracture [relative hazard (RH)=2.3; 95% CI 1.3, 4.0]. When stratified by fracture type the predictive risk was more marked for hip (RH=7.7; 95% CI 2.3, 25.9) and humerus fracture (RH=4.5; 95% CI 1.4, 14.6) than other sites (RH=1.6; 95% CI 0.6, 4.3). Additional adjustment for prevalent vertebral deformity and previous (non-rib) low trauma fractures at other sites slightly reduced the strength of the association between rib fracture and

  9. Rheological Characteristics of Cement Grout and its Effect on Mechanical Properties of a Rock Fracture

    Science.gov (United States)

    Liu, Quansheng; Lei, Guangfeng; Peng, Xingxin; Lu, Chaobo; Wei, Lai

    2018-02-01

    Grouting reinforcement, which has an obvious strengthening effect on fractured rock mass, has been widely used in various fields in geotechnical engineering. The rheological properties of grout will greatly affect its diffusion radius in rock fractures, and the water-cement ratio is an important factor in determining the grouting flow patterns. The relationship between shear stress and shear rate which could reflect the grout rheological properties, the effects of water-cement ratio, and temperature on the rheological properties of grouting was studied in the laboratory. Besides, a new method for producing fractured rock specimens was proposed and solved the problem of producing natural fractured rock specimens. To investigate the influences of grouting on mechanical properties of a rock fracture, the fractured rock specimens made using the new method were reinforced by grouting on the independent designed grouting platform, and then normal and tangential mechanical tests were carried out on fractured rock specimens. The results showed that the mechanical properties of fractured rock mass are significantly improved by grouting, the peak shear strength and residual strength of rock fractures are greatly improved, and the resistance to deformation is enhanced after grouting. Normal forces affect the tangential behavior of the rock fracture, and the tangential stress strength increases with normal forces. The strength and stability of fractured rock mass are increased by grouting reinforcement.

  10. Cortical Blindness In Fat Embolism Syndrome Following Fracture Manipulative Procedure

    Directory of Open Access Journals (Sweden)

    A Shahrulazua

    2010-03-01

    Full Text Available Fat embolism syndrome is a well-recognised sequela of long bone trauma as well as intramedullary orthopaedic procedures. However, it has rarely been described following manipulation, reduction of fracture, and application of external fixator. Furthermore, bilateral ocular blindness is seldom the first manifestation; instead respiratory and other cerebral symptoms being most common. We describe a case with this rare presentation in a patient who underwent a trial of closed reduction, then open reduction of a femur fracture, followed by external fixation performed at day 47 post-initial trauma.

  11. [PRELIMINARY APPLICATION OF VIRTUAL PREOPERATIVE RECONSTRUCTION PLANNING IN Pilon FRACTURES].

    Science.gov (United States)

    Wang Xiaoping; Wei, Zhantu; Huang, Jian; Chen, Luyao; Hu, Shiqiang; Wu, Weiwei; Tu, Yumin; Guo, Sheng; Xu, Guotai; Deng, Zhicheng

    2016-01-01

    To investigate the application value of three-dimensional reconstruction and virtual preoperative planning for Pilon fractures. Between July 2010 and June 2014, 16 patients with closed Pilon fracture were treated, including 12 males and 4 females with an average age of 36.5 years (range, 22-53 years) and a mean disease duration of 10.2 days (range, 6-14 days). According to AO/Orthopaedic Trauma Association (AO/OTA) typing, 2 cases were rated as 43.B2 type, 3 cases as 43.B3 type, 3 cases as 43.C1 type, 2 cases as 43.C2 type, and 6 cases as 43.C3 type. The preoperative CT data from 16 patients were imported into Mimics10.01 software to establish the detailed fracture three-dimensional digital models. Virtual operation of fracture reduction and implanting internal fixation was performed on the models, and the optional surgical planning was made. Based on the virtual preoperative planning, operations were performed. Established detailed three-dimensional Pilon fracture digital models could perfectly reflect the fracture characteristics, could be observed at any direction, and aided for fracture classification accurately. Virtual fracture operations of reduction, internal fixation and other could be performed to simulate the clinical operation, which could assist the surgeon better preoperative planning in achieving visual presentation and improving the communication. The operation time was 70-130 minutes (mean, 87.8 minutes); intraoperative blood loss volume was 30-150 mL (mean, 71.9 mL). The wounds healed by first intension in all patients. The mean follow-up time was 11.6 months (range, 8-18 months). Postoperative radiological results at 3 groups showed good anatomic reduction according to the Burwell-Charnley criteria, and the fracture healing time was 3-6 months (mean, 3.7 months). There was no complication of internal fixation loosening or breakage during follow-up. The American Orthopedic Foot and Ankle Society (AOFAS) score was 71-100 (mean, 92.3); the results

  12. Rib fractures in trauma patients: does operative fixation improve outcome?

    Science.gov (United States)

    Majak, Peter; Næss, Pål A

    2016-12-01

    Renewed interest in surgical fixation of rib fractures has emerged. However, conservative treatment is still preferred at most surgical departments. We wanted to evaluate whether operative treatment of rib fractures may benefit severely injured patients. Several studies report a reduction in mechanical ventilation time, ICU length of stay (LOS), hospital LOS, pneumonia, need for tracheostomy, pain and costs in operatively treated patients with multiple rib fractures compared with patients treated nonoperatively. Although patient selection and timing of the operation seem crucial for successful outcome, no consensus exists. Mortality reduction has only been shown in a few studies. Most studies are retrospective cohort and case-control studies. Only four randomized control trials exist. Conservative treatment, consisting of respiratory assistance and pain control, is still the treatment of choice in the vast majority of patients with multiple rib fractures. In selected patients, operative fixation of fractured ribs within 72 h postinjury may lead to better outcome. More randomized control trials are needed to further determine who benefits from surgical fixation of rib fractures.

  13. Functional outcome of intra-articular tibial plateau fractures: the impact of posterior column fractures.

    Science.gov (United States)

    van den Berg, Juriaan; Reul, Maike; Nunes Cardozo, Menno; Starovoyt, Anastasiya; Geusens, Eric; Nijs, Stefaan; Hoekstra, Harm

    2017-09-01

    INTRODUCTION: Although regularly ignored, there is growing evidence that posterior tibial plateau fractures affect the functional outcome. The goal of this study was to assess the incidence of posterior column fractures and its impact on functional outcome and general health status. We aimed to identify all clinical variables that influence the outcome and improve insights in the treatment strategies. A retrospective cohort study including 218 intra-articular tibial plateau fractures was conducted. All fractures were reclassified and applied treatment was assessed according to the updated three-column concept. Relevant demographic and clinical variables were studied. The patient reported outcome was assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS). Median follow-up was 45.5 (IQR 24.9-66.2) months. Significant outcome differences between operatively and non-operatively treated patients were found for all KOOS subscales. The incidence of posterior column fractures was 61.9%. Posterior column fractures, sagittal malalignment and an increased complication rate were associated with poor outcome. Patients treated according to the updated three-column concept, showed significantly better outcome scores than those patients who were not. We could not demonstrate the advantage of posterior column fracture fixation, due to a limited patient size. Our data indicates that implementation of the updated three-column classification concept may improve the surgical outcome of tibial plateau fractures. Failure to recognize posterior column fractures may lead to inappropriate utilization of treatment techniques. The current concept allows us to further substantiate the importance of reduction and fixation of posterior column fractures with restoration of the sagittal alignment. 3.

  14. Posttraumatic Proximal Radioulnar Synostosis after Closed Reduction for a Radial Neck and Olecranon Fracture

    Directory of Open Access Journals (Sweden)

    Patrick R. Keller

    2018-01-01

    Full Text Available Posttraumatic proximal radioulnar synostosis (PPRUS is a severe complication of radial head and neck fractures known to occur after severe injury or operative fixation. Cases of PPRUS occurring after minimally displaced, nonoperatively treated radial neck injuries are, by contrast, extremely rare. Here, we present a pediatric case of PPRUS that developed after a nonoperatively treated minimally displaced radial neck fracture with concomitant olecranon fracture. While more cases are needed to establish the association between this pattern of injury and PPRUS, we recommend that when encountering patients with a minimally displaced radial neck fracture and a concomitant elbow injury, the rare possibility of developing proximal radioulnar synostosis should be considered.

  15. Experimental assessment of the sealing effectiveness of rock fracture grouting

    International Nuclear Information System (INIS)

    Schaffer, A.; Daemen, J.J.K.

    1987-03-01

    The objective of this investigation is to determine the effectiveness of cement grouts as sealants of fractures in rock. Laboratory experiments have been conducted on seven 15-cm granite cubes containing saw cuts, three 23-cm diameter andesite cores containing induced tension cracks, and one 15-cm diameter marble core containing a natural fracture. Prior to grouting, the hydraulic conductivity of the fractures is determined under a range of normal stresses, applied in loading and unloading cycles, from 0 to 14 MPa (2000 psi). Grout is injected through an axial borehole, at a pressure of 1.2 to 8.3 MPa (180 to 1200 psi), pressure selected to provide a likely groutable fracture aperture, while the fracture is stressed at a constant normal stress. The fracture permeability is measured after grouting. Flow tests on the ungrouted samples confirm the inverse relation between normal stress and fracture permeability. The equivalent aperture determined by these tests is a reliable indicator of groutability. Postgrouting permeability measurements as performed here, and frequently in practice, can be misleading, since incomplete grouting of fractures can result in major apparent reductions in permeability. The apparent permeability reduction is caused by grouting of a small area of a highly preferential flowpath directly adjacent to the hole used for grouting and for permeability testing. Experimental results confirm claims in the literature that ordinary portland cement inadequately penetrates fine fractures

  16. Correlation between quarter-point angle and nuclear radius

    Science.gov (United States)

    Ma, Wei-Hu; Wang, Jian-Song; Mukherjee, S.; Wang, Qi; Patel, D.; Yang, Yan-Yun; Ma, Jun-Bing; Ma, Peng; Jin, Shi-Lun; Bai, Zhen; Liu, Xing-Quan

    2017-04-01

    The correlation between quarter-point angle of elastic scattering and nuclear matter radius is studied systematically. Various phenomenological formulae with parameters for nuclear radius are adopted and compared by fitting the experimental data of quarter point angle extracted from nuclear elastic scattering reaction systems. A parameterized formula related to binding energy is recommended, which gives a good reproduction of nuclear matter radii of halo nuclei. It indicates that the quarter-point angle of elastic scattering is quite sensitive to the nuclear matter radius and can be used to extract the nuclear matter radius. Supported by National Natural Science Foundation of China (U1432247, 11575256), National Basic Research Program of China (973 Program)(2014CB845405 and 2013CB83440x) and (SM) Chinese Academy of Sciences President’s International Fellowship Initiative (2015-FX-04)

  17. Spinopelvic Fixation of Sacroiliac Joint Fractures and Fracture-Dislocations: A Clinical 8 Years Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Mohammad R. Sobhan

    2016-10-01

    Full Text Available Background: Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient’s quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations.   Methods: Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed’s score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described Results: The injury was unilateral in 11 (78.5% patients and bilateral in 3 (21.5%. Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4% and 1 (7.1% cases, respectively. In this study most patients (85% return to work postoperatively. Conclusion: According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.

  18. Treatment of high-energy pilon fractures using the ILIZAROV treatment

    OpenAIRE

    Osman, Walid; Alaya, Zeineb; Kaziz, Hamdi; Hassini, Lassad; Braiki, Meriem; Naouar, Nader; Ben Ayeche, Mohamed Laaziz

    2017-01-01

    The management of high-energy pilon fractures is still controversial. Open reduction and internal fixation are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. The aim of this retrospective study was to analyze the clinical and radiographic outcome of the ILIZAROV technique in patients with high-energy pilon fractures. Thirty cases of distal tibia epiphysis fractures (pilon fractures) were managed from 1999 to 2012. Th...

  19. Threading the Needle: Intrapelvic Displacement of a Femoral Neck Fracture through the Obturator Foramen

    Directory of Open Access Journals (Sweden)

    Gautham Prabhakar

    2018-01-01

    Full Text Available Despite timely and appropriate management, displaced femoral neck fractures are often devastating injuries for the young patient. The risk of negative sequelae is further amplified with increasing displacement and vertical fracture patterns. Open anatomic reduction with rigid internal fixation is essential to maximize the healing potential in displaced fractures of the femoral neck. Successful primary osteosynthesis of significantly displaced femoral neck fractures in the young patient has been reported in the literature. We present a unique case of open reduction and internal fixation of a high-energy femoral neck fracture with extrusion of the head through the obturator foramen into the pelvis without associated acetabular or pelvic injury.

  20. Medial joint space widening of the ankle in displaced Tillaux and Triplane fractures in children.

    Science.gov (United States)

    Gourineni, Prasad; Gupta, Asheesh

    2011-10-01

    Tillaux and Triplane fractures occur in children predominantly from external rotation mechanism. We hypothesized that in displaced fractures, the talus would shift laterally along with the distal fibula and the distal tibial epiphyseal fragment increasing the medial joint space. Consecutive cases evaluated retrospectively. Level I and Level II centers. Twenty-two skeletally immature patients with 14 displaced Triplane fractures and eight displaced Tillaux fractures were evaluated for medial joint space widening. Measurement of fracture displacement and medial joint space widening before and after intervention. Thirteen Triplane and six Tillaux fractures (86%) showed medial space widening of 1 to 9 mm and equal to the amount of fracture displacement. Reduction of the fracture reduced the medial space to normal. There were no known complications. Medial space widening of the ankle may be a sign of ankle fracture displacement. Anatomic reduction of the fracture reduces the medial space and may improve the results in Tillaux and Triplane fractures.

  1. Open Fracture of the Forearm Bones due to Horse Bite

    Directory of Open Access Journals (Sweden)

    John Ashutosh Santoshi

    2014-01-01

    Full Text Available Introduction: Fractures have been described mainly following falling accidents in horse-related injuries. Horse bites are uncommon accidents. We present a case of open fracture of the forearm due to horse bite. Case Report: A 35-year-old male farm-worker presented to the emergency room with alleged history of horse bite to the right forearm about 2 hours prior to presentation while feeding the horse. There was deformity of the forearm with multiple puncture wounds, deep abrasions and small lacerations on the distal-third of the forearm. Copious irrigation with normal saline was done and he was administered anti-tetanus and post-exposure rabies prophylaxis. Prophylactic antibiotic therapy was commenced. Radiographs revealed fracture of radius and ulna in the mid-shaft region. He underwent emergency wound debridement, and the ulna was stabilised with an intra-medullary square nail. Seventy-two hours later, he underwent re-debridement and conversion osteosynthesis. He had an uneventful recovery and at three-month follow-up, the fractures had healed radiographically in anatomic alignment. At two-year follow-up, he is doing well, is pain free and has a normal range of motion compared to the contralateral side. Conclusion: Horse bites behave as compound fractures however rabies prophylaxis will be needed and careful observation is needed. Early radical debridement, preliminary skeletal stabilisation, re-debridement and conversion osteosynthesis to plate, and antibiotic prophylaxis were the key to the successful management of our patient. Keywords: Horse; animal bite; forearm; open fracture

  2. Analysis of PITFL injuries in rotationally unstable ankle fractures.

    Science.gov (United States)

    Warner, Stephen J; Garner, Matthew R; Schottel, Patrick C; Hinds, Richard M; Loftus, Michael L; Lorich, Dean G

    2015-04-01

    Reduction and stabilization of the syndesmosis in unstable ankle fractures is important for ankle mortise congruity and restoration of normal tibiotalar contact forces. Of the syndesmotic ligaments, the posterior inferior tibiofibular ligament (PITFL) provides the most strength for maintaining syndesmotic stability, and previous work has demonstrated the significance of restoring PITFL function when it remains attached to a posterior malleolus fracture fragment. However, little is known regarding the nature of a PITFL injury in the absence of a posterior malleolus fracture. The goal of this study was to describe the PITFL injury pattern based on magnetic resonance imaging (MRI) and intraoperative observation. A prospective database of all operatively treated ankle fractures by a single surgeon was used to identify all supination-external rotation (SER) types III and IV ankle fracture patients with complete preoperative orthogonal ankle radiographs and MRI. All patients with a posterior malleolus fracture were excluded. Using a combination of preoperative imaging and intraoperative findings, we analyzed the nature of injuries to the PITFL. In total, 185 SER III and IV operatively treated ankle fractures with complete imaging were initially identified. Analysis of the preoperative imaging and operative reports revealed 34% (63/185) had a posterior malleolus fracture and were excluded. From the remaining 122 ankle fractures, the PITFL was delaminated from the posterior malleolus in 97% (119/122) of cases. A smaller proportion (3%; 3/122) had an intrasubstance PITFL rupture. Accurate and stable syndesmotic reduction is a significant component of restoring the ankle mortise after unstable ankle fractures. In our large cohort of rotationally unstable ankle fractures without posterior malleolus fractures, we found that most PITFL injuries occur as a delamination off the posterior malleolus. This predictable PITFL injury pattern may be used to guide new methods for

  3. Echinococcal disease of the bone: An unusual cause of a pathological fracture

    Directory of Open Access Journals (Sweden)

    Matthew Goodier

    2010-12-01

    Full Text Available Echinococcosis is caused by the larva of the tapeworm, Echinococcus granulosus or Echinococcus multiloccularis and is endemic in many rural areas of Southern Africa. Echinococcosis of the bone is an unusual manifestation of echinococcal disease and a rare cause of a lytic lesion of bone. This report describes a 30-yr old female who presented with an Echinococcal cyst of the right radius complicated by a pathological fracture.

  4. Multiscale model reduction for shale gas transport in fractured media

    KAUST Repository

    Akkutlu, I. Y.; Efendiev, Yalchin R.; Vasilyeva, Maria

    2016-01-01

    fracture distributions on an unstructured grid; (2) develop GMsFEM for nonlinear flows; and (3) develop online basis function strategies to adaptively improve the convergence. The number of multiscale basis functions in each coarse region represents

  5. Prognosis of teeth in the line of mandibular fracture: 5 - year clinical ...

    African Journals Online (AJOL)

    The focus was on 96 teeth in the line of mandibular fracture retained after reduction and immobilization of the fracture by closed reduction technique. The clinical and radiological follow-up period of patients ranged between six months and 3.5 years. RESULTS: Majority of the patients 33 (53.2%) were in their third decade of ...

  6. Facial nerve injuries associated with the retromandibular transparotid approach for reduction and fixation of mandibular condyle fractures.

    Science.gov (United States)

    Shi, Dan; Patil, Pavan Manohar; Gupta, Ritika

    2015-04-01

    To document facial nerve (FN) injuries after surgical treatment of mandibular condylar fractures using the retromandibular transparotid approach and to identify risk factors associated with these injuries. A retrospective study of patients surgically treated for mandibular condylar fractures using the retromandibular transparotid approach over seven years was conducted. The primary study variable was the postoperative change in FN function after fracture fixation. Risk factors were categorized as demographic, anatomic, experience of the operator, fracture displacement/dislocation and number of miniplates placed at the fracture site. Appropriate statistics were computed. Ninety patients with 102 fractures were analysed. Thirty two fractures (31%) were located in the condylar neck and 70 fractures (69%) were subcondylar (located below the sigmoid notch). The condylar segment was undisplaced in twelve cases (12%), displaced medially in thirty five (34%), laterally displaced in thirty (29%) and dislocated in 25 (24.5%). In 18 fractures (18%), postoperative examination revealed various degrees of damage to the FN. All nerve injuries recovered completely in 8-24 weeks. In a multivariate model, condylar neck fractures, fracture dislocation and operator inexperience were associated with a statistically significant risk of postoperative deterioration of FN function (P ≤ 0.05). The majority of facial nerve injuries after surgical treatment of condylar fractures by the retromandibular transparotid approach are transient in nature. Condylar neck fractures, fracture dislocation and operator inexperience were associated with an increased risk for FN injury. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Radius Determination of Solar-type Stars Using Asteroseismology: What to Expect from the Kepler Mission

    Science.gov (United States)

    Stello, Dennis; Chaplin, William J.; Bruntt, Hans; Creevey, Orlagh L.; García-Hernández, Antonio; Monteiro, Mario J. P. F. G.; Moya, Andrés; Quirion, Pierre-Olivier; Sousa, Sergio G.; Suárez, Juan-Carlos; Appourchaux, Thierry; Arentoft, Torben; Ballot, Jerome; Bedding, Timothy R.; Christensen-Dalsgaard, Jørgen; Elsworth, Yvonne; Fletcher, Stephen T.; García, Rafael A.; Houdek, Günter; Jiménez-Reyes, Sebastian J.; Kjeldsen, Hans; New, Roger; Régulo, Clara; Salabert, David; Toutain, Thierry

    2009-08-01

    For distant stars, as observed by the NASA Kepler satellite, parallax information is currently of fairly low quality and is not complete. This limits the precision with which the absolute sizes of the stars and their potential transiting planets can be determined by traditional methods. Asteroseismology will be used to aid the radius determination of stars observed during NASA's Kepler mission. We report on the recent asteroFLAG hare-and-hounds Exercise#2, where a group of "hares" simulated data of F-K main-sequence stars that a group of "hounds" sought to analyze, aimed at determining the stellar radii. We investigated stars in the range 9 values of the artificial stars to within 3%, when the large frequency spacing is used. This is 5-10 times better than the results where seismology is not applied. These results give strong confidence that radius estimation can be performed to better than 3% for solar-like stars using automatic pipeline reduction. Even when the stellar distance and luminosity are unknown we can obtain the same level of agreement. Given the uncertainties used for this exercise we find that the input log g and parallax do not help to constrain the radius, and that T eff and metallicity are the only parameters we need in addition to the large frequency spacing. It is the uncertainty in the metallicity that dominates the uncertainty in the radius.

  8. Femoral neck fractures after removal of hardware in healed trochanteric fractures.

    Science.gov (United States)

    Barquet, Antonio; Giannoudis, Peter V; Gelink, Andrés

    2017-12-01

    Hardware removal in healed trochanteric fractures (TF) in the absence of infection or significant mechanical complications is rarely indicated. However, in patients with persistent pain, prominent material and discomfort in the activities of daily living, the implant is eventually removed. Publications of ipsilateral femoral neck fracture after removal of implants from healed trochanteric fractures (FNFARIHTF) just because of pain or discomfort are rare. The purpose of this systematic review of the literature is to report on the eventual risk factors, the mechanisms, the clinical presentation, and frequency, and to pay special emphasis in their prevention. A comprehensive review of the literature was undertaken using the PRISMA guidelines with no language restriction. Case reports of FNFARIHTF and series of TF with cases of FNFARIHTF due to pain or discomfort published between inception of journals to December 2016 were eligible for inclusion. Relevant information was divided in two parts. Part I included the analysis of cases of FNFARIHTF, with the objective of establishing the eventual risk factors, mechanisms and pathoanatomy, clinical presentation and diagnosis, treatment and prevention. Part II analyzed series of TF which included cases of FNFARIHTF for assessing the incidence of femoral neck fractures in this condition. Overall 24 publications with 45 cases of FNFARIHTF met the inclusion criteria. We found that the only prevalent factors for FNFARIHTF were: 1) preexisisting systemic osteoporosis, as most patients were older and elder females, with lower bone mineral density and bone mass; 2) local osteoporosis as a result of preloading by the fixation device in the femoral neck, leading to stress protection, reducing the strain at the neck, and increasing bone loss and weakness; and 3) the removal of hardware from the femoral neck, with reduction of the failure strength of the neck. The femoral neck fractures were spontaneous, i.e. not related to trauma or

  9. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    International Nuclear Information System (INIS)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M.

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed

  10. Fracture behavior of circumferentially surface-cracked elbows. Technical report, October 1993--March 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kilinski, T.; Mohan, R.; Rudland, D.; Fleming, M. [and others

    1996-12-01

    This report presents the results from Task 2 of the Second International Piping Integrity Research Group (IPIRG-2) program. The focus of the Task 2 work was directed towards furthering the understanding of the fracture behavior of long-radius elbows. This was accomplished through a combined analytical and experimental program. J-estimation schemes were developed for both axial and circumferential surface cracks in elbows. Large-scale, quasi-static and dynamic, pipe-system, elbow fracture experiments under combined pressure and bending loads were performed on elbows containing an internal surface crack at the extrados. In conjunction with the elbow experiments, material property data were developed for the A106-90 carbon steel and WP304L stainless steel elbow materials investigated. A comparison of the experimental data with the maximum stress predictions using existing straight pipe fracture prediction analysis methods, and elbow fracture prediction methods developed in this program was performed. This analysis was directed at addressing the concerns regarding the validity of using analysis predictions developed for straight pipe to predict the fracture stresses of cracked elbows. Finally, a simplified fitting flaw acceptance criteria incorporating ASME B2 stress indices and straight pipe, circumferential-crack analysis was developed.

  11. Numerical Radius Inequalities for Finite Sums of Operators

    Directory of Open Access Journals (Sweden)

    Mirmostafaee Alireza Kamel

    2014-12-01

    Full Text Available In this paper, we obtain some sharp inequalities for numerical radius of finite sums of operators. Moreover, we give some applications of our result in estimation of spectral radius. We also compare our results with some known results.

  12. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  13. Conservative management of fracture scaphoid

    Directory of Open Access Journals (Sweden)

    Mittal V

    2006-01-01

    Full Text Available Background : Conservative management of fracture scaphoid with cast is still the most common modality of management, but the results following this protocol are not always satisfactory. Methods : Twenty five patients with fracture scaphoid were treated with a below elbow scaphoid cast and were followed up for minimum duration of one year. On follow up patients were examined clinicoradiologically and functional results were evaluated using the modification of the Mayo wrist scoring chart. Results : Nineteen fractures showed union, two were malunited and five went for nonunion. Two fractures developed avascular necrosis and three patients had wrist arthritis on follow up. Nineteen patients had excellent functional results, one had good results and six patients had poor results. Patients with delayed diagnosis had nonunion and poor functional results. Patients with premature removal of cast had comparatively inferior results Conclusion : For displaced unstable fracture, open reduction and internal fixation should be the preferred modality of treatment as cast treatment gives unacceptably high rate of malunion and nonunion with poor functional results.

  14. Management of Mandibular Fracture in a Peripheral Health Setting ...

    African Journals Online (AJOL)

    Hp 630 Dual Core

    and immobilization using intermaxillary fixation (IMF) to the more invasive surgical sopens reduction with internal ... normal anatomic positions7, and prevention of movement by immobilization (fixation) of the fractured bone thereby ... Appearance of the patient after healing of fracture occurred intra orally. Due to the limited ...

  15. Reduction and Fixation of Unstable Fractures of the Zygomatic Arch ...

    African Journals Online (AJOL)

    Radiographs in the occipitomental and submentovertex views are most ... the bone and zygomatic arch, depending on the location of the fracture points and ... lesions in the facial nerve. ... [1,2] Thus, the diagnosis of this condition is based on ...

  16. Radionuclide scintimetry for diagnosis of complications following femoral neck fracture

    International Nuclear Information System (INIS)

    Alberts, K.A.; Dahlborn, M.; Hindmarsh, J.; Soederborg, B.; Ringertz, H.

    1984-01-01

    A scintimetric study using Tc-99m MDP was made of 54 patients with delayed union, nonunion, or late segmental collapse of the femoral head, 4-92 months after femoral neck fracture. In radiographically verified collapse, the radionuclide uptake ratio between the femoral head on the fractured and on the intact side (HHR) was significantly higher than in fractures resulting in delayed union or nonunion. On the basis of scintimetric and radiographic findings, the patients with healing disturbances could be divided into three groups, characterized by the following features: (1) Satisfactory post-reduction position of the fracture without subsequent redisplacement and a high HHR, which as a rule turned out to be delayed union; (2) The same radiographic pattern but with a lower HHR, which in most cases resulted in nonunion; (3) Inadequate reduction or early redisplacement of the fracture with a high HHR, which resulted in nonunion. The fractional precision in discriminating between different types of disturbed fracture healing by means of skeletal scintimetry was 0.86 in this study. This non-invasive and technically simple method would therefore be a valuable complement to radiography in the assessment of healing, more than 4 months after fracture of the femoral neck. (author)

  17. Do Open Reduction and Internal Fixation With Articular Disc Anatomical Reduction and Rigid Anchorage Manifest a Promising Prospect in the Treatment of Intracapsular Fractures?

    Science.gov (United States)

    Cai, Bo-Lei; Ren, Rong; Yu, Hong-Bo; Liu, Peng-Chao; Shen, Steve G F; Shi, Jun

    2018-05-01

    In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. A PROSPECTIVE STUDY OF DISTAL TIBIAL FRACTURES BY MIPO (LCP

    Directory of Open Access Journals (Sweden)

    Chandra Sekharam Naidu

    2015-05-01

    Full Text Available INTRODUCTION: D istal tibial fractures represent a significant challenge to most of the surgeons even today. They constitute 1 - 10% of all lower extremity fractures . 1 The difficulty in treating the fractures of distal tibial end is exemplif ied by orthopedists, who in the first half of twentieth century, believed these injuries were so severe and fraught with so many complications, that these fractures were deemed not amenable for surgical reconstruction . 2 Conservative treatment by POP cast l ead to prolonged immobilization, leading to ankle and knee stiffness affecting quality of life of the patient . 3 Operative treatment is indicated for most tibial fractures caused by high energy trauma. Operative treatment allows early motion, and avoids sho rtening and other complications associated with prolonged immobilization . 4 The fundamental goal of treatment of distal tibial fractures is restoration of normal or near normal alignment and articular congruity and finally to obtain a well healed fracture; pain free weight bearing ; and functional ROM of ankle joint. For the past decade, plating has been successful in treating complex fractures of the lower extremity especially distal tibia . 5 Conventional ORIF have been associated with complications like infe ction and delayed or non - union due to devitalisation of bony fragments and additional damage to the soft tissues . 6 To improve fracture healing, more “biological” methods have been developed in the last decade to lessen the surgical dissection, preserving b lood supply to bony fragments and containing at least partially the fracture haematoma . 7 Recently, the trend is towards use of a Locking compression plate for treatment of fractures of the distal part of the tibia 8 . Compared with a conventional plate, a Lo cking compression plate imparts a higher degree of stability and provides better protection against primary and secondary losses of reduction and minimization of bone

  19. [APPLICATION OF COMPUTER-ASSISTED SURGICAL PLANNING IN SURGICAL TREATMENT OF ANKLE FRACTURES].

    Science.gov (United States)

    Xia, Shengli; Wang, Xiuhui; Fu, Beigang; Lu, Yaogang; Wang, Minghui

    2015-12-01

    To explore the clinical value of computer-assisted surgical planning in the treatment of ankle fractures. Between January 2012 and January 2014, open reduction and internal fixation were performed on 42 patients with ankle fractures. There were 22 males and 20 females with an average age of 52 years (range, 19-72 years). The causes were spraining injury (20 cases), traffic accident injury (14 cases), and falling from height injury (8 cases). The time from injury to operation was 5 hours to 12 days (mean, 2.5 days). All fractures were closed trimalleolar fractures. According to Lauge-Hansen classification, 25 cases were rated as supination extorsion type IV, 13 as pronation extorsion type IV, and 4 as pronation abduction type III. The preoperative planning was made by virtual reduction and internal fixation using Superimage software. The mean operation time was 93.7 minutes (range, 76-120 minutes). Delayed wound healing occurred in 1 case, and secondary healing was obtained after treatment; primary healing of incision was achieved in the other patients. Postoperative X-ray films and CT images showed anatomic reduction of fracture and good position of internal fixation. All patients were followed up 14.6 months on average (range, 9-27 months). The range of motion of the affected ankle was close to the normal side at 6-8 weeks. The mean fracture healing time was 13.1 weeks (range, 11-17 weeks). Degenerative change of the ankle joint was observed in 3 cases (7.1%) with manifestation of mild narrowing of joint space on the X-ray films at last follow-up. According to Baird-Jackson score system, the results were excellent in 24 cases, good in 13 cases, and fair in 5 cases, with an excellent and good rate of 88%. Computer-assisted surgical planning for ankle fractures can help surgeons identify type of ankle fractures and improve surgical scheme for guiding fracture reduction and selecting and placing implants, so good effectiveness can be obtained.

  20. Postirradiation fracture toughness of Inconel X-750

    International Nuclear Information System (INIS)

    Mills, W.J.

    1983-01-01

    The effect of fast-neutron irradiation on the fracture toughness response of Inconel X-750 was characterized at 427 deg C using the J-R curve technique. Irradiation exposures ranging from 3 to 16 displacements per atom resulted in a reduction in Jsub(Ic) from 130 to 76 kJ/m 2 and a reduction in tearing modulus from 32 to 2.6. Postirradiation fractographic examination revealed that an intergranular fracture mechanism was dominant, in contrast to the extensive transgranular cracking mode found on unirradiated fracture surfaces. The enhanced intergranular failure observed after irradiation was caused by extensive heterogeneous slip in a matrix that was greatly strengthened by an irradiation-induced dislocation substructure. Specifically, intense planar slip bands impinged on the grain boundaries and generated large stress concentrations. Since the stress concentrations could not be relaxed by the hardened matrix, the grain boundaries 'unzipped' readily, resulting in the low toughness and tearing resistance. (author)