WorldWideScience

Sample records for radius fracture reduction

  1. HAEMATOMA BLOCK- AN EFFECTIVE ALTERNATIVE TO GENERAL ANAESTHESIA FOR REDUCTION OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Prabhati Rani Mishra

    2016-12-01

    Full Text Available BACKGROUND Most common fracture in elderly patients is distal radius fracture. The most common method of management is closed reduction and immobilisation. The aim of the study is to compare the analgesic effects of haematoma block and general anaesthesia for closed reduction of distal fracture of radius. MATERIALS AND METHODS A prospective randomised controlled study was carried out among 100 patients of age group between 15-70 years of either sex who had fracture distal radius between 2015-2016. The patients having multiple fractures, pathological fractures or suffering from any organic diseases were excluded from the study. After taking informed written consent, the patients were randomised into two equal groups. In group A, reduction of fracture was done following administration of IV propofol and in group B after infiltration with 2% lignocaine into fracture haematoma site. Pain score was compared by VAS before, during and after manipulation in both the groups. Time taken from presentation at emergency department to reduction and discharge from hospital was also compared. Statistical analysis was done by applying SPSS software. RESULTS 100 patients of mean age 42.5 years, male: female 43:57 with fracture distal radius were studied. Mean time from admission to fracture reduction in group A was 2.64±0.93 hours and in group B 0.90±0.45 hours (P=0.0001. Discharge time from hospital after reduction of fracture in group A was 4.24±0.94 hours and in group B 0.75±0.2 hours (P=0.0001. VAS during reduction in group A was 0 and in group B 0.98±0.8 (P=0.0001. 10 minutes after reduction VAS in group A was 2.28±0.24 and group B 0.72±0.45 (P=0.0001. CONCLUSION For closed reduction of distal radius fracture, haematoma block with lignocaine is safe and effective alternative to intravenous general anaesthesia with propofol.

  2. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    International Nuclear Information System (INIS)

    Jaremko, J.L.; Lambert, R.G.W.; Rowe, B.H.; Johnson, J.A.; Majumdar, S.R.

    2007-01-01

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal (∼6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 ± 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary

  3. Do radiographic indices of distal radius fracture reduction predict outcomes in older adults receiving conservative treatment?

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, J.L. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Lambert, R.G.W. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta (Canada); Rowe, B.H. [Department of Emergency Medicine, University of Alberta, Edmonton, Alberta (Canada); Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Johnson, J.A. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada); Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada); Majumdar, S.R. [Department of Public Health Sciences, University of Alberta, Edmonton, Alberta (Canada) and Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta (Canada)]. E-mail: me2.majumdar@ualberta.ca

    2007-01-15

    Aim: To investigate whether radiographic deformities suggesting inadequate reduction would be associated with adverse clinical outcomes. Materials and methods: Consecutive patients over 50 years of age (n = 74) with non-operatively managed distal radius fractures were enrolled in a prospective cohort study. They had radiographs at cast removal ({approx}6 weeks) and completed DASH (Disabilities of the Arm, Shoulder and Hand), SF-12 (health-related quality of life), and satisfaction surveys 6-months post-fracture. A reference-standard musculoskeletal radiologist, blinded to outcomes status, measured palmar (dorsal) tilt, radial angle, radial height, ulnar height, and intra-articular step and gap. Radiographic indices were correlated to each other and to the various patient-reported outcomes in univariate and multivariate regression analyses. DASH score was the primary study outcome. Results: Of the cohort studied (n = 74, mean age 68.5 years, primarily white women), 71% had at least one 'unacceptable' radiographic deformity by traditional criteria. Acceptable reduction varied from 60-99% depending on which single index was reported, and 44% of patients had more than two indices reported as unacceptable. Despite these radiographic findings, 6-months post-reduction, self-reported disability was low (DASH = 24 {+-} 17), health-related quality of life was near normal, and 72% were satisfied with their care. No radiographic index of wrist deformity (alone or in combination) was significantly correlated to any of the patient-reported outcomes. Conclusion: Self-reported outcomes in older adults with conservatively managed wrist fractures were not related to the 'acceptability' of radiographic fracture reduction. The proportion of acceptable reductions varied by 40% depending on which index was reported. Consequently, detailed reporting of these indices in older adults with distal radius fracture may be inefficient or perhaps even unnecessary.

  4. Nerve Stimulator Guided Axillary Block in Painless Reduction of Distal Radius Fractures; a Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Hossein Alimohammadi

    2013-12-01

    Full Text Available Introduction: Given the high prevalence of upper extremity fractures and increasing need to perform painless reduction in the emergency departments, the use of analgesic methods with fewer complications and more satisfaction appears to be essential. The aim of this study is comparison the nerve stimulator guided axillary block (NSAB with intravenous sedation in induction of analgesia for painless reduction of distal radius fractures. Methods: In the present randomized clinical trial, 60 patients (18-70 years of age suffered from distal radius fractures, were divided into two equal groups. One group received axillary nerve block by nerve stimulator guidance and the other procedural sedation and analgesia (PSA using midazolam/fentanyl. Onset of analgesia, duration of analgesic effect, total procedure time and pain scores were recorded using visual analogue scale (VAS and the outcomes were compared. Chi-squared and student t test were performed to evaluate differences between two groups. Results: Sixty patients were randomly divided into two groups (83.3% male. The mean age of patients was 31 ±0.7 years. While the onset of analgesia was significantly longer in the NSAB group, the mean total time of procedure was shorter than PSA (p<0.001. The NSAB group needed a shorter post-operative observation time (P<0.001. Both groups experienced equal pain relief before, during and after procedure (p>0.05. Conclusion: It seems that shorter post-operative monitoring time and consequently lesser total time of procedure, make nerve stimulator guided axillary block as an appropriate alternative for procedural sedation and analgesia in painless reduction of distal radius fractures in emergency department. 

  5. Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Chris Dillingham

    2011-01-01

    Full Text Available Purpose. To determine recovery timeline of unstable distal radius fractures treated by open reduction and internal fixation with a locking volar plate. Methods. Data was collected prospectively on a consecutive series of twenty-seven patients during routine post-operative visits at 2 and 6 weeks, and 3, 6, 12 and 24 months. Range of motion measures and grip strength for both wrists were recorded. Results. Greatest gains were made within the first 3 months after surgery. Supination and pronation returned more quickly than flexion or extension, with supination and pronation both at 92% of the uninjured wrist at 3 months. Only flexion improved significantly between 3 and 6 months. All wrist motions showed some improvement until 1 year. Grip strength returned to 94% of the uninjured wrist by 12 months. Conclusions. Range of motion improvement will be greatest between 2 weeks and 3 months, with improvement continuing until 12 months. Grip strength should return to near normal by one year. Function and pain will improve, but not return to normal by the end of 12 months. Clinical Relevance. These results provide the surgeon with information that can be shared with patients on the anticipated timeline for normal recovery of function and strength.

  6. [Complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2016-12-20

    Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P 0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.

  7. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach.

    Science.gov (United States)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-07-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  8. Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu

    2010-01-01

    The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopy-guided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of ≥2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after

  9. [Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures: a meta-analysis].

    Science.gov (United States)

    Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L

    2017-11-07

    Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.

  10. Radius crossover sign: an indication of malreduced radius shaft greenstick fractures.

    Science.gov (United States)

    Wright, Patrick B; Crepeau, Allison E; Herrera-Soto, José A; Price, Charles T

    2012-06-01

    Radius shaft greenstick fractures in children can be a challenging injury to treat because angulation and rotational alignment are difficult to assess. In this report, we describe a simple method for analyzing the deformity and identifying rotational and angular malalignment. This technique involves analyzing the forearm radiographs as 2 segments, proximal and distal, and assuring that the rotational position of each matches the other. We present 3 cases of proximal radius greenstick fractures in malalignment to demonstrate the radius crossover sign. Identifying the radius crossover sign, and proceeding with further closed reduction may prevent deformity that could otherwise result in a significant loss of forearm motion. Level V.

  11. Fractures of the distal radius in children: A retrospective evaluation

    Directory of Open Access Journals (Sweden)

    Selma Yazıcı

    2012-06-01

    Full Text Available Objectives: This study designed to evaluate the resultsof treatment, closed reduction and percutaneous wires, ofthe distal radius fractures in children.Materials and methods: A retrospective analysis wascarried out in children aged between 5-15 years who presentedwith a displaced fracture of the distal radius to ourhospital. They were initially treated with closed reductionand cast immobilization. If the fractures redisplaced treatedby percutaneous Kirschner (K- wire with scope undera general anaesthesia.Results: Totally 104 patients, who have distal radius fractureswere treated by closed reduction and immobilizationin a plaster cast. 13 patient who have distal radiusfractures were treated by closed reduction under generalanaesthesia and fixed by percutaneous Kirschner (K-wire. Patients with impaired the alignment of the fracturein late period were usually completely displaced fractures.(n=5, 4,3%, in early period, completely displaced fractures(n=5, 4,3% are superior to partial displaced fractures(n=2, 1,7%.Conclusion: In our study, when children with distal radiusfracture first come, they were treated by closed reductionand immobilization in a plaster cast. We thought that inredisplaced fractures patients were suitable for the closedreduction with percutaneous wire treatment.

  12. Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008-2015).

    Science.gov (United States)

    De Arburn Parent, Rebecca; Benamou, Jérôme; Gatineau, Matthieu; Clerfond, Pierre; Planté, Jérôme

    2017-06-15

    OBJECTIVE To determine outcomes and complication rates of open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs. DESIGN Retrospective case series. ANIMALS 102 miniature- and toy-breed dogs (105 fractures) weighing ≤ 7 kg (15.4 lb) that had undergone open reduction and cranial bone plate fixation of a fracture involving the distal aspect of the radius and ulna from 2008 through 2015. PROCEDURES Medical records were reviewed and information extracted regarding dog and fracture characteristics, surgical variables, and follow-up examination data (including postoperative complications). Postoperative radiographs were examined for distal fragment size, implant placement, apposition, alignment, and healing stage. A long-term follow-up questionnaire was completed by telephone interview with dog owners at least 6 months after surgery. RESULTS Mean length of the distal bone fragment in all fractures was 19.2 mm, with a mean distal-to-total radial length ratio of 0.21. At last follow-up examination (typically 6 weeks after surgery), 97 (95%) dogs had no signs of lameness; minor lameness was identified in 5 (5%) dogs. Complications developed in 26 (25%) fractures (23 [22%] minor and 3 [3%] major complications). Sixty-eight of 71 (96%) owners rated the overall and long-term outcome as excellent and 3 (4%) as good; 68 of 71 (96%) dogs reportedly had no signs of residual lameness. CONCLUSIONS AND CLINICAL RELEVANCE Open reduction and cranial bone plate fixation for the treatment of radius-ulna fractures in miniature- and toy-breed dogs provided an excellent outcome with a low complication rate.

  13. Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon's perspective.

    Science.gov (United States)

    Wichlas, Florian; Tsitsilonis, Serafim; Kopf, Sebastian; Krapohl, Björn Dirk; Manegold, Sebastian

    2017-01-01

    Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius fractures were treated with open reduction and internal fixation through palmar, dorsal, and dorsopalmar approaches with 2.4 mm locking plates or underwent percutaneous fixation. The parameters that should replace the surgeon's analysis were the fractured palmar cortex, and the frontal and the sagittal split of the articular surface of the distal radius. Results: The palmar approach was used for 422 (84.4%) fractures, the dorsal approach for 39 (7.8%), and the combined dorsopalmar approach for 30 (6.0%). Nine (1.8%) fractures were treated percutaneously. The correlation between the fractured palmar cortex and the used palmar approach was moderate (r=0.464; p<0.0001). The correlation between the frontal split and the dorsal approach, including the dorsopalmar approach, was strong (r=0.715; p<0.0001). The sagittal split had only a weak correlation for the dorsal and dorsopalmar approach (r=0.300; p<0.0001). Discussion: The study shows that the surgical decision on the preferred approach is dictated through two simple factors, even in the case of complex fractures. Conclusion: When the palmar cortex is displaced in distal radius fractures, a palmar approach should be used. When there is a displaced frontal split of the articular surface, a dorsal approach should be used. When both are present, a dorsopalmar approach should be used. These two simple parameters could replace the surgeon's analysis for the surgical approach.

  14. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID: protocol for a randomized clinical multi-center trial

    Directory of Open Access Journals (Sweden)

    Seiler Christoph

    2011-03-01

    Full Text Available Abstract Background Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation. Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. Methods/Design ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool. The primary objective is to determine differences in the Short Form 36 (SF-36 Physical Component Score (PCS between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery, as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture

  15. Open reduction and internal fixation versus casting for highly comminuted and intra-articular fractures of the distal radius (ORCHID): protocol for a randomized clinical multi-center trial.

    Science.gov (United States)

    Bartl, Christoph; Stengel, Dirk; Bruckner, Thomas; Rossion, Inga; Luntz, Steffen; Seiler, Christoph; Gebhard, Florian

    2011-03-22

    Fractures of the distal radius represent the most common fracture in elderly patients, and often indicate the onset of symptomatic osteoporosis. A variety of treatment options is available, including closed reduction and plaster casting, K-wire-stabilization, external fixation and open reduction and internal fixation (ORIF) with volar locked plating. The latter is widely promoted by clinicians and hardware manufacturers. Closed reduction and cast stabilization for six weeks is a simple, convenient, and ubiquitously available intervention. In contrast, ORIF requires hospitalization, but allows for functional rehabilitation.Given the lack of randomized controlled trials, it remains unclear whether ORIF leads to better functional outcomes one year after injury than closed reduction and casting. ORCHID (Open reduction and internal fixation versus casting for highly comminuted intra-articular fractures of the distal radius) is a pragmatic, randomized, multi-center, clinical trial with two parallel treatment arms. It is planned to include 504 patients in 15 participating centers throughout Germany over a three-year period. Patients are allocated by a central web-based randomization tool.The primary objective is to determine differences in the Short Form 36 (SF-36) Physical Component Score (PCS) between volar locked plating and closed reduction and casting of intraarticular, comminuted distal radius fractures in patients > 65 years of age one year after the fracture. Secondary outcomes include differences in other SF-36 dimensions, the EuroQol-5D questionnaire, the Disability of the Arm, Shoulder, and Hand (DASH) instrument. Also, the range of motion in the affected wrist, activities of daily living, complications (including secondary ORIF and revision surgery), as well as serious adverse events will be assessed. Data obtained during the trial will be used for later health-economic evaluations. The trial architecture involves a central statistical unit, an independent

  16. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  17. Classification and treatment of distal radius fractures: a survey among orthopaedic trauma surgeons and residents

    NARCIS (Netherlands)

    M.A.M. Mulders (Marjolein A. M.); D. Rikli; J.C. Goslings (Carel); N.W.L. Schep (Niels)

    2017-01-01

    textabstractPurpose: Classification, the definition of an acceptable reduction and indications for surgery in distal radius fracturemanagement are still subject of debate. The purpose of this study was to characterise current distal radius fracture management in Europe. Methods: During the European

  18. Factors Associated with Infection Following Open Distal Radius Fractures

    OpenAIRE

    Glueck, Dane A.; Charoglu, Constantine P.; Lawton, Jeffrey N.

    2009-01-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone factures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated wi...

  19. Two peg spade plate for distal radius fractures A novel technique

    Directory of Open Access Journals (Sweden)

    Sharad M Hardikar

    2015-01-01

    Conclusions: The two peg volar spade plate provides a stable subchondral support in comminuted intraarticular fractures and maintains reduction in osteoporotic fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and to prevent development of wrist stiffness.

  20. Social Support Contributes to Outcomes following Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Caitlin J. Symonette

    2013-01-01

    Full Text Available Background. Distal radius fractures are the most common fracture of the upper extremity and cause variable disability. This study examined the role of social support in patient-reported pain and disability at one year following distal radius fracture. Methods. The Medical Outcomes Study Social Support Survey was administered to a prospective cohort of 291 subjects with distal radius fractures at their baseline visit. Pearson correlations and stepwise linear regression models (F-to-remove 0.10 were used to identify whether social support contributes to wrist fracture outcomes. The primary outcome of pain and disability at one year was measured using the Patient Rated Wrist Evaluation. Results. Most injuries were low energy (67.5% and were treated nonoperatively (71.9%. Pearson correlation analysis revealed that higher reported social support correlated with improved Patient Rated Wrist Evaluation scores at 1 year, r(n=181=-0.22, P<0.05. Of the subscales within the Social Support Survey, emotional/informational support explained a significant proportion of the variance in 1-year Patient Rated Wrist Evaluation scores, R2=4.7%, F (1, 181 = 9.98, P<0.05. Conclusion. Lower emotional/informational social support at the time of distal radius fracture contributes a small but significant percentage to patient-reported pain and disability outcomes.

  1. Factors associated with infection following open distal radius fractures.

    Science.gov (United States)

    Glueck, Dane A; Charoglu, Constantine P; Lawton, Jeffrey N

    2009-09-01

    Open fractures are often classified according to a system described by Gustilo and Anderson. However, this system was applied to open long bone fractures, which may not predict the incidence of infection in open metaphyseal fractures of the upper extremity. Other studies have found that wound contamination and systemic illness were the best predictors of infections in open hand fractures. Our study assessed infection in open distal radius fractures and identifies factors that are associated with these infections. We hypothesize that contamination, rather than absolute wound size, is the best predictor of infection associated with open distal radius fractures. A review by CPT code yielded 42 patients with open distal radius fractures between 1997 and 2002 treated at a level one trauma center. Medical records and radiographic follow-up were reviewed to assess the time to irrigation and debridement, the number of debridements in initial treatment period, the method of operative stabilization, the Gustilo and Anderson type of fracture, the Swanson type of fracture, and description of wound contamination. Forty-two patients were followed up for an average of 15 months (range 4 to 68 months). Twenty-four fractures were classified as Gustilo and Anderson type I, ten were type II, and eight were type III, 30 were Swanson type I, and 12 were Swanson type II. Five of the 42 fractures were considered contaminated. Two were exposed to fecal contamination. The others were contaminated with tar, dirt/grass, and gravel, respectively. Three of 42 (7%) fractures developed infections. All three infected cases received a single irrigation and debridement. Two of five contaminated fractures (40%) developed a polymicrobial infection. Both were exposed to fecal contamination and, therefore, considered Swanson type II fractures. They were classified as Gustilo and Anderson type II and IIIB based solely upon the size of the wound. Both required multiple debridements and eventually wrist

  2. Risk Factors Associated With Survival to Hospital Discharge of 54 Horses With Fractures of the Radius.

    Science.gov (United States)

    Stewart, Suzanne; Richardson, Dean; Boston, Ray; Schaer, Thomas P

    2015-11-01

    To determine (1) survival to discharge of horses with radial fractures (excluding osteochondral fragmentation of the distal aspect of the radius and stress fractures); and (2) risk factors affecting survival to hospital discharge in conservative and surgically managed fractures. Case series. Horses (n = 54). Medical records (1990-June 2012) and radiographs of horses admitted with radial fracture were reviewed. Horses with osteochondral fragmentation of the distal aspect of the radius or stress fractures were excluded. Evaluated risk factors were age, fracture configuration, surgical repair method, surgical duration, hospitalization time, implant failure rate, and surgical site infection (SSI) rate. Of 54 horses, overall survival to discharge was 50%. Thirteen (24%) were euthanatized on admission because of (1) fracture severity; (2) presence of an open fracture; or (3) financial constraints. Fourteen (26%) horses with minimally displaced incomplete fractures were conservatively managed and 12 (86%) survived to discharge. Twenty-seven (50%) horses had surgical treatment by open reduction and internal fixation (ORIF) and 15 (56%) survived to hospital discharge. Open fractures were significantly more likely to develop SSI (P = .008), which also resulted in a 17-fold increase in implant failure (P horses with an open fracture did not survive to discharge. Outcome was also adversely affected by age (P 168 minutes (P fractures is good. Young horses have a good prognosis survival to discharge for ORIF, whereas ORIF in adult horses has a poor prognosis and SSI strongly correlates with catastrophic implant failure. © Copyright 2015 by The American College of Veterinary Surgeons.

  3. Fractures of the shafts of the radius and ulna

    International Nuclear Information System (INIS)

    Bender, C.E.; Campbell, D.C.

    1985-01-01

    Although the clinical presentation of fracture of the forearm bones is usually quite obvious, thorough radiologic examination of the radius and ulna and adjacent wrist and elbow joints is mandatory. Standard views of the forearm of the patient include the AP and lateral projections. The degree of shortening, angulation, rotation, and comminution should be noted. The selected films must be long enough to include the adjacent elbow and wrist joints

  4. AO Distal Radius Fracture Classification: Global Perspective on Observer Agreement

    Science.gov (United States)

    Jayakumar, Prakash; Teunis, Teun; Giménez, Beatriz Bravo; Verstreken, Frederik; Di Mascio, Livio; Jupiter, Jesse B.

    2016-01-01

    Background The primary objective of this study was to test interobserver reliability when classifying fractures by consensus by AO types and groups among a large international group of surgeons. Secondarily, we assessed the difference in inter- and intraobserver agreement of the AO classification in relation to geographical location, level of training, and subspecialty. Methods A randomized set of radiographic and computed tomographic images from a consecutive series of 96 distal radius fractures (DRFs), treated between October 2010 and April 2013, was classified using an electronic web-based portal by an invited group of participants on two occasions. Results Interobserver reliability was substantial when classifying AO type A fractures but fair and moderate for type B and C fractures, respectively. No difference was observed by location, except for an apparent difference between participants from India and Australia classifying type B fractures. No statistically significant associations were observed comparing interobserver agreement by level of training and no differences were shown comparing subspecialties. Intra-rater reproducibility was “substantial” for fracture types and “fair” for fracture groups with no difference accounting for location, training level, or specialty. Conclusion Improved definition of reliability and reproducibility of this classification may be achieved using large international groups of raters, empowering decision making on which system to utilize. Level of Evidence Level III PMID:28119795

  5. A PROSPECTIVE STUDY OF CLINICAL OUTCOME AFTER USING LIGAMENTOTAXIS IN MANAGEMENT OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Chandrashekhar V. Mudgal

    2017-04-01

    Full Text Available BACKGROUND A study was done to evaluate the effect of the ligamentotaxis in the management of intraarticular fractures of the distal radius. MATERIALS AND METHODS 34 patients were studied prospectively between March 2014 and February 2016. All patients had intraarticular fracture of distal end of radius and all were treated with ligamentotaxis after closed reduction with fluoroscopic guidance. The follow-up period was 12 months. At the time of surgery, the mean age was 45.29 years. RESULTS In all fracture cases, the mean of fracture union was 5.8 weeks. During the final follow-up, the mean range of motion was 55.30 in flexion, 56.60 in extension, 21.0 in ulnar deviation, 9.00 in radial deviation, 70.30 in pronation and 67.10 in supination. According to the scoring system of Gartland and Werley, the clinical and functional outcomes showed that 15 patients (44.1% had excellent results, 14 (41.1% had good results, 3 (8.8% had fair results and 2 (5.8% had poor results. CONCLUSION Closed reduction under fluoroscopic image guidance and the ligamentotaxis is useful and effective in the treatment of intraarticular fractures of the distal radius.

  6. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  7. Ipsilateral simultaneous fracture of the trochlea involving the lateral end clavicle and distal end radius: a rare combination and a unique mechanism of injury

    Directory of Open Access Journals (Sweden)

    Gupta RK

    2014-07-01

    Full Text Available 【Abstract】Isolated trochlea fracture in adults is a rare surgical entity as compared to its capitellar counterpart. It has been only mentioned sporadically in the literature as case reports. Fracture of the trochlea is accompanied by other elbow injuries like elbow dislocation, capitellum fracture, ulnar fracture and extraarticular condylar fracture. Here we report a unique case of isolated displaced trochlea fracture associated with fractures of the lateral end clavicle and the distal end radius. We propose a unique mechanism for this rare combination of injuries: typical triad of injury, i.e. fracture of the distal end radius with trochlea and fracture of the lateral end of the clavicle. Nonoperative treatment is recommended for undisplaced humeral trochlea fractures; but for displaced ones, anatomical reduction and internal fixation are essential to maintain the congruous trochleacoronoid articulation and hence to maintain the intrinsic stability of the elbow. Key words: Isolated trochlea fracture; Clavicle; Radius fractures

  8. Pathologic fracture of the distal radius in a 25-year-old patient with a large unicameral bone cyst.

    Science.gov (United States)

    Massen, Felix; Baumbach, Sebastian; Volkmer, Elias; Mutschler, Wolf; Grote, Stefan

    2014-06-13

    Distal radius fractures (DRF) are often referred to as osteoporosis indicator fractures as their incidence increases from age 45. In the group of young adults, distal radius fractures normally result from high-energy trauma. Wrist fractures in young patients without adequate trauma thus raise suspicion of a pathologic fracture. In this report we present the case of a fractured unicameral bone cyst (UBC) at the distal radius in a young adult.To the author's best knowledge, this is the first detailed report in an UBC at the distal radius causing a pathologic DRF in an adult patient. A 25-year-old otherwise healthy male presented to our Emergency Department after a simple fall on his right outstretched hand. Extended diagnostics revealed a pathologic, dorsally displaced, intra-articular distal radius fracture secondary to a unicameral bone cyst occupying almost the whole metaphysis of the distal radius. To stabilize the fracture, a combined dorsal and volar approach was used for open reduction and internal fixation. A tissue specimen for histopathological examination was gathered and the lesion was filled with an autologous bone graft harvested from the ipsilateral femur using a reamer-irrigator-aspirator (RIA) system. Following one revision surgery due to an intra-articular step-off, the patient recovered without further complications. Pathologic fractures in young patients caused by unicameral bone cysts require extended diagnostics and adequate treatment. A single step surgical treatment is reasonable if fracture and bone cyst are treated appropriately. Arthroscopically assisted fracture repair may be considered in intra-articular fractures or whenever co-pathologies of the carpus are suspected.

  9. Non-operative treatment of displaced distal radius fractures leads to acceptable functional outcomes, however at the expense of 40% subsequent surgeries

    NARCIS (Netherlands)

    Mulders, M. A. M.; van Eerten, P. V.; Goslings, J. C.; Schep, N. W. L.

    2017-01-01

    Background: Although secondary displacement following closed reduction and plaster immobilisation is high, several guidelines still recommend non-operative treatment for displaced distal radius fractures with an adequate closed reduction. Purpose: The purpose of this study was to evaluate functional

  10. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  11. "Osteoporosis and orthopods" incidences of osteoporosis in distal radius fracture from low energy trauma.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-07-01

    Fracture of the distal radius from low energy trauma is a common presentation to orthopaedic trauma services. This fragility type fracture is associated with underlying osteoporosis. Osteoporosis is a \\'silent disease\\' where fragility fracture is a common presentation. Orthopaedic surgeons may be the only physician that these patients encounter. We found a high percentage of female patients who sustained a fragility fracture of the distal radius have an underlying osteoporosis. Further management of osteoporosis is important to prevent future fragility fractures.

  12. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  13. Analysis of the Arthroscopically Diagnosed Soft-Tissue Injuries Associated With the Distal Radius Fractures

    Directory of Open Access Journals (Sweden)

    Katerina Katerina Kasapinova

    2014-06-01

    CONCLUSIONS: The frequency of the associated soft-tissue lesions in distal radius fractures is high. Ulnar styloid fracture was identified as risk factor for associated LT lesion, as well as combined lesion of both scapholunate and luntriquetral ligament.

  14. Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator.

    Science.gov (United States)

    Tyllianakis, Minos; Mylonas, Spyros; Saridis, Alkis; Kallivokas, Alkiviadis; Kouzelis, Antonis; Megas, Panagiotis

    2010-03-01

    Unstable distal radius fractures remain a challenge for the treating orthopaedic surgeon. We present a retrospective follow-up study (mean follow-up 12.5 months) of 20 patients with 21 unstable distal radius fractures that were reduced in a closed manner and stabilized with a nonbridging Ilizarov external fixator. Subsequent insertion of olive wires for interfragmentary compression was performed in cases with intra-articular fractures. According to the overall evaluation proposed by Gartland and Werley scoring system 12 wrists were classified as excellent, 6 as good, 2 as fair and 1 as poor. Grade II pin-tract infection in distal fracture fragment was detected in 3 wires from a total of 78 (3.8%) and in 4 half pins out of a total of 9 (44.4%). Pronation was the most frequently impaired movement. This was restricted in 4 patients (19%) in whom a radioulnar transfixing wire was applied. Symptoms of irritation of superficial sensory branch of the radial nerve occurred in 3 patients with an olive wire applied in a closed manner in the distal fragment. Ilizarov method yields functional results comparable to that of other methods whilst it avoids wrist immobilization, open reduction and reoperation for implant removal. The method is associated with a low rate of major complication and satisfactory functional outcome. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. [Roof folding and rotary pushing for the treatment of back to back fractures of distal radius and ulna in children].

    Science.gov (United States)

    Xu, Ping; Dong, Xiao-jun; Lu, Zhou-tong; Wang, Gongjun; Zhang, Han-qing; Chen, Xuan-ning; Li, Dong

    2015-09-01

    To evaluate the technique and the clinical effect of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back". From January 2012 to February 2014,38 children with distal radius and ulna fracture of "back to back" were treated by using the technique of folding roof and rotary pushing to reset and splint fixation including 23 males and 15 females with an average age of 9.5 years old ranging from 6 to 14 years old. Injury time was from 45 min to 3 days (averaged 1.3 days). All cases was unilateral closed fracture without symptoms of nerve injury occurred. The wrist joint anteroposterior and lateral radiographs showed double fracture of radius and ulna, and the broken end of radius was typical "back to back" displacement. The quality of reduction was assessed according to Dienst recommendation on the combination of Aro measurement, and the therapeutic effect was evaluated using standard of Anderson function. All patients were followed up from 3 to 13 months with an average of 6 months. There were no iatrogenic nerve injury. Thirty cases were treated successfully for the first time, 8 cases were again reset successfully; 28 cases were anatomical reduction, 7 cases were near anatomic reduction, 3 cases were functional reduction. At the second day 7 cases with hand and finger swelling appeared in multiple reset patients. Quality results of reduction were excellent in 33 cases, good in 5 cases. According to the standard of Anderson function evaluation, 35 cases were excellent, 3 cases were good. All fractures were healed with of deformity of wrist. Using the technique of folding roof and rotary pushing in treatment of children with distal radius and ulna fracture of "back to back" is very successful, the patient's limb function recovered well, the whole operation process is simple.

  16. Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

    Science.gov (United States)

    Seeley, Mark A; Fabricant, Peter D; Lawrence, J Todd R

    2017-09-01

    Approximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement. A distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the

  17. Radiographic diagnosis of scapholunate dissociation among intra-articular fractures of the distal radius: interobserver reliability

    NARCIS (Netherlands)

    Gradl, Gertraud; Neuhaus, Valentin; Fuchsberger, Thomas; Guitton, Thierry G.; Prommersberger, Karl-Josef; Ring, David; Wahegaonkar, Abhijeet L.; Shafritz, Adam B.; Garcia, Aida E.; Caputo, Andrew E.; Terrono, Andrew L.; Spoor, Andy B.; Eschler, Anica; Vochteloo, Anne J. H.; Beumer, Annechien; Barquet, Antonio; Kristan, Anze; van der Zwan, Arnard L.; Berner, Arne; Ilyas, Asif; Jubel, Axel; Sutker, Ben; Nolan, Betsy M.; Petrisor, Brad; Cross, Brian J.; Wills, Brian P. D.; Barreto, Camilo J. R.; Fernandes, Carlos H.; Swigart, Carrie; Zalavras, Charalampos; Goldfarb, Charles A.; Cassidy, Charles; Eaton, Charles; Wilson, Chris; Cheng, Christine J.; Wall, Christopher J.; Walsh, Christopher J.; Jones, Christopher M.; Garnavos, Christos; Klostermann, Cyrus; Kirkpatrick, D. Kay; Eygendaal, Denise; Verbeek, Diederik O. F.; Beeres, Frank J. P.; Thomas, George; Ponsen, Kornelis J.; van den Bekerom, Michel P. J.; Schep, Niels; Kloen, Peter; Haverlag, Robert

    2013-01-01

    To evaluate the reliability and accuracy of diagnosis of scapholunate dissociation (SLD) among AO type C (compression articular) fractures of the distal radius. A total of 217 surgeons evaluated 21 sets of radiographs with type C fractures of the distal radius for which the status of the

  18. Relationship between plate removal and Soong grading following surgery for fractured distal radius

    NARCIS (Netherlands)

    Selles, Caroline A.; Reerds, Sam T. H.; Roukema, Gert; van der Vlies, Kees H.; Cleffken, Berry I.; Schep, Niels W. L.

    2018-01-01

    The aim of this study was to determine the relationship between volar plate removal and the Soong classification following fixation for fractured distal radius. In this retrospective cohort study, all consecutive patients who had volar plate fixation for a distal radius fracture in 2011-2015 were

  19. Outcome of management of distal radius fractures in ...

    African Journals Online (AJOL)

    Background and Purpose: Distal radial fractures are common fractures of postmenopausal age group patients. They are often called fractures of osteoporosis. These fractures are considered to be one of the commonest minor injuries to cause major morbidity in the community. A lot of patient who need surgery, fail to afford ...

  20. The shaft fractures of the radius and ulna in children: current concepts.

    Science.gov (United States)

    Sinikumpu, Juha-Jaakko; Serlo, Willy

    2015-05-01

    The incidence of forearm shaft fractures in children has increased in recent years. They are challenging to treat and they can result in several long-lasting complications. The treatment of children's fractures needs to be individualized to their needs. Nonoperative care will be satisfactory for young, preschool children and it is primarily treatment in stable fractures of children at every age. Injury mechanism must be understood to perform appropriate closed reduction. Immobilization using a long-arm cast needs to be focused against the deforming muscle forces - in particular those that rotate - in the forearm, keeping the bones in alignment until bone healing. Operative stabilization by elastic stable intramedullary nailing is the primarily method of treatment in cases of unstable fractures, in particular, in children between preschool age and adolescence. For older children near to skeletal maturity, a rigid plate and screw fixation will be justified. The most common complication after closed treatment is worsening of the alignment and need for repetitive interventions. elastic stable intramedullary nailing results usually in good outcome, and range of forearm rotation is the main feature determining the clinical result. In this article, we report the current concept of paediatric shaft fractures in the radius and ulna.

  1. Evaluation of sarcopenia in patients with distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Koh, Young Do; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Sarcopenia is more prevalent in patients with distal radius fracture (DRF) than in age- and sex-matched controls. Lower appendicular mass index in men and weaker grip strength in both men and women increase the likelihood of DRF. Sarcopenia is a core component of physical frailty that predisposes older people to falls and negatively impacts the activities of daily living. The objectives of this study were to compare the prevalence of sarcopenia in patients with DRF with that in age- and sex-matched controls without DRF; and evaluate the association between sarcopenia and the occurrence of DRF. We prospectively recruited 132 patients over 50 years of age who sustained DRF due to fall and 132 age- and sex-matched controls without DRF. A definition of sarcopenia was based on the consensus of the Asian Working Group for Sarcopenia. Sarcopenic components including appendicular lean body mass, grip strength, and gait speed were compared between the two groups. Other factors assessed for the occurrence of DRF were age, gender, body mass index (BMI), lumbar, and hip bone mineral density (BMD) values. A conditional logistic regression analysis was conducted to evaluate the associations between sarcopenia and the occurrence of DRF. A total of 39 (30%) of 132 DRF patients were sarcopenic, whereas 23 (17%) of the 132 controls were within the sarcopenic criteria (p = 0.048). The patient group had significantly lower lean body mass and weaker grip strength than those of the control group. However, there was no significant difference in gait speed between the two groups. According to regression analysis, lower appendicular mass index in men was associated with an increased incidence of DRF (odds ratio [OR] = 0.84, 95% confidence interval [CI] = 0.72, 0.95) while weaker grip strength and lower total hip BMD values were associated with the occurrence of DRF in both men (OR = 0.77, 95% CI = 0.63, 0.92; and OR = 0.79, 95% CI = 0.64, 0.94, respectively) and women (OR

  2. Does formal education and training of staff reduce the operation rate for fractures of the distal radius?

    Science.gov (United States)

    McDonald, Kyle; Murphy, Lynn; Gallagher, Brendan; Eames, Niall

    2013-12-01

    Fractures of the distal radius are one of the most common extremity fractures, and operation rates are increasing. Staff within our unit felt that formal teaching, particularly of new medical staff, with regards to fracture reduction and appropriate cast application could result in a reduction in operation rates. Retrospective data was extracted from FORD (Fracture Outcome and Research Database), including: number of fractures, number of fractures undergoing ORIF, fracture configuration, patient demographics, and mechanism of injury. All patients undergoing ORIF had their radiographs assessed by two separate reviewers. Information regarding adequate fracture reduction, adequate cast application (using Gap Index), and appropriate plaster cast moulding was recorded. Formal teaching was then given to the next group of medical staff rotating through the unit, and the same data was collected prospectively for that six-month period. Exclusion criteria included bilateral injuries, and polytrauma patients. A total of 1623 distal radial fractures were treated in our unit over the 12-month period, with 71 undergoing ORIF in the first 6 months and 39 in the second 6 months, this was statistically significant (p = 0.0009). Our study found that formal teaching and education significantly reduced the operation rate for distal radial fractures. This effect was most significant for extra-articular, dorsally angulated fractures of the distal radius. Our study proves that just 1 h of basic training at the beginning of an attachment can have significant benefits to both the unit and, more importantly, the patients. Copyright © 2013 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  3. Assessment of "YouTube" Content for Distal Radius Fracture Immobilization.

    Science.gov (United States)

    Addar, Abdullah; Marwan, Yousef; Algarni, Nizar; Berry, Gregory

    Distal radius fractures (DRFs) are the most common orthopedic fractures, with >70% of cases treated by closed immobilization using a short arm cast or a sugar tong splint. However, inadequate immobilization is a risk factor for loss of reduction requiring repeat reduction or surgical treatment. Therefore, education of clinical skills for appropriate immobilization of DRFs is important. With the increasing use of web-based information by medical learners, our aim was to assess the quality and quantity of videos regarding closed immobilization of DRFs on YouTube. Retrospective review of YouTube videos on distal radius fracture immobilization using specific search terms. Identified videos were analyzed for their educational value, quality of the technical skill demonstrated, and overall metrics. Educational value was scored on a 5-point scale, with "1" indicative of low quality and "5" of high quality. Not applicable. Among the 68,366 videos identified, 16 met our inclusion criteria of being in English; performed by a health care professional or institution; and with casting being the major theme of the educational information provided. Of these 16 videos, 6 had an educational value score of 4 or 5, with the remaining 10 having a score ≤3. Although immobilization was demonstrated by cast technician specialized in orthopedics, skills were also performed by orthopedic attendants, urgent care physicians, orthopedic residents, and nurse practitioners. The credentials of the performer in 3 videos were not identified. There is a need to promote high-quality educational videos produced by established medical school faculty members on open, web-based, portals. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. A STUDY ON FRACTURE FIXATION OF DISTAL END OF RADIUS BY PERCUTANEOUS PINNING

    Directory of Open Access Journals (Sweden)

    Kiran Kumar L

    2016-07-01

    Full Text Available BACKGROUND Various treatment modalities have been described for the treatment of distal radius fractures each with its own merits and demerits. Most of the work done with percutaneous pinning has shown a significant residual stiffness of the hand and wrist. Our technique involves percutaneous pinning of the fracture and immobilisation in neutral position of the wrist for. This study's aim was to examine the functional outcome of percutaneous K-wiring of these distal radius fractures with immobilisation in neutral position of the wrist. METHODS A prospective study conducted on thirty adult patients with distal radial fractures treated at Department of Orthopaedics, Rangaraya Medical college, Kakinada between October 2013 to September 2015. RADIOGRAPHIC EXAMINATION Standard radiographs in PA and lateral views were taken for confirmation of the diagnosis and also to know the type of fracture. Oblique views were also taken in a few patients who had complex comminuted fractures. The fracture fragments were analysed and involvement of radiocarpal and distal radioulnar joints were assessed and classified according to the Frykman classification. Of the cases, 6(20% of the fractures were type I, 2(6.6% of type II, 3(10% of type III, 6(20% of type IV, 8(26.6% of type V, 5(16.6% of type VI, no cases of type VII and VIII.SURGICAL PROCEDURE The procedures were performed under regional anaesthesia in all cases. After sterile preparation and draping, fracture is reduced by traction and the reduction was evaluated fluoroscopically. A 1.5 cm incision given longitudinally (if needed beginning at the radial styloid and proceeds proximally across to the medial metaphysis and diaphysis. At least two pins (1.6 mm Kirschner wire were inserted and adequate reduction was confirmed on AP/LAT views under image intensifier. Another 1.6 mm K-wire percutaneously 90 degrees orthogonally to these wires starting at the dorsal rim of distal radius just distal to the Lister

  5. [Injury to the Scapholunate Ligament in Distal Radius Fractures: Peri-Operative Diagnosis and Treatment Results].

    Science.gov (United States)

    Gajdoš, R; Pilný, J; Pokorná, A

    2016-01-01

    PURPOSE OF THE STUDY Injury to the scapholunate ligament is frequently associated with a fracture of the distal radius. At present neither a unified concept of treatment nor a standard method of diagnosis in these concomitant injuries is available. The aim of the study was to evaluate a group of surgically treated patients with distal radius fractures in order to assess a contribution of combined conventional X-ray and intra-operative fluoroscopic examinations to the diagnosis of associated lesions and to compare short-term functional outcomes of sugically treated patients with those of patients treated conservatively. MATERIAL AND METHODS A group of patients undergoiong surgery for distal radius fractures using plate osteosynthesis was evaluated retrospectively. The peri-operative diagnosis of associated injury to the scapholunate ligament was based on pre-operative standard X-ray views and intra-operative fluoroscopy. The latter consisted of images of maximum radial and ulnar deviation as well as an image of the forearm in traction exerted manually along the long axis. All views were in postero-anterior projection. Results were read directly on the monitor of a fluoroscopic device after its calibration or were obtained by comparing the thickness of an attached Kirschner wire with the distance to be measured. Subsequently, pixels were converted to millimetres. When a scapholunate ligament injury was found and confirmed by examination of the contralateral wrist, the finding was verified by open reduction or arthroscopy. Both static and dynamic instabilities were treated together with the distal radius fracture at one-stage surgery. After surgery, the patients without ligament injury had the wrist immobilised for 4 weeks, then rehabilitation followed. In the patients with a damaged ligament, immobilisation in a short brace lasted until transarticular wires were removed. All patients were followed up for a year at least. At follow-up, the injured wrist was examined

  6. Peak incidence of distal radius fractures due to ice skating on natural ice in The Netherlands

    NARCIS (Netherlands)

    van Lieshout, Arno P. W.; van Manen, Christiaan J.; du Pré, Karel J.; Kleinlugtenbelt, Ydo V.; Poolman, Rudolf W.; Goslings, J. Carel; Kloen, Peter

    2010-01-01

    An increase of distal radius fractures was seen in 2009 when an extended cold spell allowed natural ice skating in Amsterdam. This resulted in overload of our Emergency Departments and operating rooms. This study reports patient and fracture characteristics of these injuries. We also determined

  7. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  8. MRI of fractures of the distal radius: comparison with conventional radiographs

    International Nuclear Information System (INIS)

    Spence, L.D.; Eustace, S.

    1998-01-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.)

  9. MRI of fractures of the distal radius: comparison with conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Spence, L.D.; Eustace, S. [Medical Center, Boston, MA (United States). Dept. of Radiol.; Savenor, A.; Nwachuku, I.; Tilsley, J. [Department of Orthopedics, Boston Medical Center, Boston, MA 02118 (United States)

    1998-05-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.) With 5 figs., 16 refs.

  10. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  11. The outcome of conservative treatment of adult distal radius fractures compared with the other wrist: radiological and functional evaluation

    Directory of Open Access Journals (Sweden)

    Mustafa Uslu

    2014-09-01

    Full Text Available Objective: This study was designed to evaluate anatomical and functional results of closed reduction-long arm cast treatment for distal radius fractures and compared other healthy wrist in the adults. Methods: 77 patients with distal radius fracture were treated conservatively between January 2010 and December 2010. The fractures were classified according to AO and Frykman classification system and investigated prospectively. The radiological and anatomical results were assessed by the Stewart score criteria. The functional results were assessed by Quick-Disability of Arm, Shoulder and Hand questionnaire (Q-DASH and the Stewart II score criteria. The mean follow-up of patients was 12 months. Results: The forty patients had right wrist fractured, 37 patients had left wrist fractured. According to Frykman classification 46 patients were type I-II fractured, according to AO classification 59 patients were type 23,A2,1 and 23,A2,2 fractured. According to Stewart the radiological and anatomical, the result were excellent in 57, good in 17, fair in 3. According to Stewart II functional criteria, the results were assessed excellent in 57, good in 8, fair in 12 The mean Q-DASH score was 6,37. The overall complication rate was 12.98%. Mild Carpal tunnel syndrome was observed in the two patients, ulna styloid nonunion in the four patients, pain of distal radioulnar joint in the one patient, mild carpal tunnel syndrome and tenderness of distal radioulnar joint in the three patients. Conclusion: Closed reduction and cast immobilization is still an effective and inexpensive treatment method in distal radial fractures. J Clin Exp Invest 2014; 5 (3: 403-409

  12. [Distal radius fractures--retrospective quality control after conservative and operative therapy].

    Science.gov (United States)

    Sommer, C; Brendebach, L; Meier, R; Leutenegger, A

    2001-01-01

    The distal radius fracture is the most frequent fracture in the adult patient. The wide spectrum of different types of fracture and the coexisting factors make the choice for the optimal treatment difficult. As an interne quality control we retrospectively evaluated all patients with distal radius fractures treated in 1995 at our institution. The study included 69 adult patients with 71 distal radius fractures. After on average 26 months 58 patients with 59 fractures were clinically and radiologically evaluated. The patients were asked to give supplementary information about their follow-up treatment as well as any remaining physical difficulties and limitations in the daily life. All x-rays of the broken radius were carefully analysed and compared with the opposite side. The final results were evaluated according to the "Demerit Point System". Patients were treated with five different therapeutical methods. 76.3% of the patients showed a very good/good final result. In 56.7% of the cases secondary fracture dislocation occurred; the dislocation-rate of fractures treated with percutaneous k-wires was 93.3%! A clear correlation between secondary displacement and final results was found. A main factor for an optimal outcome is the anatomic restoration of length and axis of the distal radius as well as of joint congruency, also moderate angular deformities are well tolerated. Our collective showed an unexpected high rate of secondary displacement, especially in the k-wire group. The reasons for this unsatisfactory event are manifold: too optimistic indication, insufficient follow-up examination in the first four to six weeks, inconsequent change to a more stable fixation method in case of a secondary dislocation. The results of this retrospective evaluation had a major impact on our concept of treatment. The dorso-radial double-plate technique combined with bone graft will be more used in the future especially in younger patients. The new standardised concept is the

  13. Immobilisation of extra-articular distal radius fractures (Colles type) in dorsiflexion. The functional and anatomical outcome.

    Science.gov (United States)

    Baruah, Ranjit Kr; Islam, Mohibul; Haque, Russel

    2015-09-01

    Cast immobilisation after successful closed reduction is a standard treatment for displaced extra-articular fractures of lower end radius. The position of the wrist during immobilisation is controversial. Immobilisation in dorsiflexion prevents redisplacement after closed reduction. Our aim is to determine the effectiveness of immobilization of wrist in dorsiflexion in such cases and evaluate anatomical and functional outcome. Study included 54 patients, above 19 years of age with closed extra-articular fractures of lower end radius treated conservatively with below elbow cast application. The wrist was maintained in 15° of dorsiflexion during plaster immobilisation. At 24 weeks, functional results were evaluated with subjective symptoms and objective signs, as per modified Demerit Point Score System. Anatomical result was evaluated based on the scheme devised by Lidstrom (1959) and modified by Sarmiento et al. (1980). 76% patients had Excellent to Good subjective symptoms. Out of 42 patients that had residual dorsal angulation of less than 10°, 37 had excellent to good functional outcome. 39 of the 43 patients who had loss of radial length less than 6 mm had excellent to good functional outcome. 40 out of 49 patients having loss of radial angulation less than 9° showed excellent to good functional outcome. Functional result was directly proportional to anatomical outcome. Cast immobilization of extra articular fractures of lower end radius with wrist in dorsiflexion prevents re-displacement of the fragments resulting in satisfactory anatomical & functional outcome.

  14. A COMPARATIVE STUDY OF CONSERVATIVE MANAGEMENT VS. EXTERNAL FIXATION OF COMMINUTED DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Kare

    2016-12-01

    Full Text Available BACKGROUND Fracture of the distal radius (‘broken wrist’ is a common clinical problem. It can be treated conservatively usually involving wrist immobilisation in a plaster cast or surgically. A key method of surgical fixation is external fixation. MATERIALS AND METHODS A prospective study was carried out on 66 patients admitted between June 2014 to May 2016 for evaluation of conservative and surgical management of distal radius fractures. RESULTS Excellent, fair or good result was noticed in around 85% of cases managed conservatively and in above 90% of cases managed by external fixator. CONCLUSION There is some evidence to support the use of external fixation for dorsally displaced fractures of the distal radius in adults. Though, there is insufficient evidence to confirm a better functional outcome, external fixation reduces redisplacement gives improved anatomical results and most of the excess surgically-related complications are minor.

  15. Fracture configurations of the equine radius and tibia after a simulated kick

    OpenAIRE

    Fürst, Anton; Oswald, Susanne E; Jäggin, S; Piskoty, G; Michel, S; Auer, Jörg A

    2008-01-01

    The objective of this postmortem study was to determine the fracture configurations of the equine radius and tibia after a simulated kick. Fracture configurations of 35 radii and 36 tibiae from 19 adult horses were evaluated after a simulated kick in an experimental exvivo study. The bones were dissected, the proximal and distal ends were embedded in resin, fixed horizontally and preloaded in compression, and a steel impactor, designed to simulate a shod equine hoof, was dropped from a height...

  16. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    Science.gov (United States)

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  17. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  18. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  19. Mid-term functional outcome after the internal fixation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Phadnis Joideep

    2012-01-01

    Full Text Available Abstract Background Distal radius fracture is a common injury with a variety of operative and non-operative management options. There remains debate as to the optimal treatment for a given patient and fracture. Despite the popularity of volar locking plate fixation, there are few large cohort or long term follow up studies to justify this modality. Our aim was to report the functional outcome of a large number of patients at a significant follow up time after fixation of their distal radius with a volar locking plate. Methods 180 patients with 183 fractures and a mean age of 62.4 years were followed up retrospectively at a mean of 30 months (Standard deviation = 10.4. Functional assessment was performed using the Disabilities of the Arm, Shoulder and Hand (DASH and modified MAYO wrist scores. Statistical analysis was performed to identify possible variables affecting outcome and radiographs were assessed to determine time to fracture union. Results The median DASH score was 2.3 and median MAYO score was 90 for the whole group. Overall, 133 patients (74% had a good or excellent DASH and MAYO score. Statistical analysis showed that no specific variable including gender, age, fracture type, post-operative immobilisation or surgeon grade significantly affected outcome. Complications occurred in 27 patients (15% and in 11 patients were major (6%. Conclusion This single centre large population series demonstrates good to excellent results in the majority of patients after volar locking plate fixation of the distal radius, with complication rates comparable to other non-operative and operative treatment modalities. On this basis we recommend this mode of fixation for distal radius fractures requiting operative intervention.

  20. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  1. Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2018-04-01

    : Locking plate and external fixation is feasible to heal radius type C fracture. We found the small difference between the two groups on imaging examination. The locking plate has the advantage on maintaining reduction, however no significant difference regarding outcomes has been found between the two groups. Keywords: Locking plate, External fixation, Type C, Distal radius fractures, Meta-analysis

  2. [Growth behaviour after fractures of the proximal radius: differences to the rest of the skeleton].

    Science.gov (United States)

    Hell, A K; von Laer, L

    2014-12-01

    Fractures of the proximal end of the radius in the growth phase have three characteristics: the head of the radius articulates with two joint partners and is therefore indispensable for an undisturbed function of the elbow. The blood supply of the proximal end of the radius is via periosteal vessels in the sense of a terminal circulation which makes it extremely vulnerable. Severe trauma caused either by accidents or treatment, can result in partial or complete necrosis with deformity of the head and neck region of the radius. Radioulnar synostosis and chronic epiphysiolysis are irreversible complications which can occur after excessive physiotherapy. Despite a low potency growth plate, in young patients the proximal end of the radius shows an enormous spontaneous correction of dislocations. Side to side shifts, however, will not be remodeled. Therapy should be as atraumatic as possible. Due to the blood supply situation, with the appropriate indications the spontaneous correction and a brief period of immobilization without physiotherapy should be integrated into the therapy concept. If an operation is necessary, repeated traumatic repositioning maneuvers should be avoided and in case of doubt closed or careful open repositioning can be achieved with intramedullary nailing. In order to take the special characteristics of the proximal radius into consideration, the vulnerability and correction potential must be weighed up against each other. Therapy must be as atraumatic as possible. The spontaneous correction potential should be integrated into the primary therapy without overestimating this potential with respect to the extent and age of the patient.

  3. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    Science.gov (United States)

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  4. Fixation via dorsal for complex fractures of radius distal with plate P

    International Nuclear Information System (INIS)

    Rojas, Sandra; Bocanegra, Sergio; Suarez, Fabio

    2002-01-01

    The existence of multiple alternatives in the handling of the complex fractures of the radius distal it constitutes a reflection of the challenge that these they represent as for the possibility of recovering an appropriate consistency to articulate and orientation and radial height. This prospective study included 13 patients assisted in the hospital military of Bogota, by means of internal fixation with plate π. This treatment alternative, it solves many present inconveniences with other methods and it allows the precocious postoperative rehabilitation

  5. The reliability of AO classification for distal radius fracture, using CT findings

    International Nuclear Information System (INIS)

    Nakanishi, Yasuaki; Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryoutarou; Ota, Hiroyoshi

    2006-01-01

    The purpose of this study was to assess the reliability of the AO (Association for the Study of Internal Fixation) classification of distal radius fracture, using plain radiographs and 2 cross-sectional computed tomographic (CT) surface images. Five observers independently classified 32 distal radius fractures into 9 groups under AO classification. We established 4 methods for observation. First, using only two-directional radiographs; second, four-directional radiographs; third, CT (axial view) with four-directional radiographs; and fourth, CT (axial and sagittal views) with four-directional radiographs. Kappa statistics were used to establish the relative level of agreement between the observers. Interobserver reliability was poor in both first and second methods in which only plain radiographs were used (κ=0.30 and 0.23, respectively). Furthermore, reliability did not increase in the third method with the addition of 1 CT surface image (κ=0.29). In the fourth method, with the addition of 2 cross-sectional CT surface images, the reliability increased to a moderate level (κ=0.44). Interobserver reliability of the AO system of the classification of distal radius fractures was observed on using 2 cross-sectional CT surface images with four-directional radiographs. (author)

  6. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    Science.gov (United States)

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  7. Effects of circumferential rigid wrist orthoses in rehabilitation of patients with radius fracture at typical site

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2005-01-01

    Full Text Available Background. The use of orthoses is a questionable rehabilitation method for patients with the distal radius fracture at typical site. The aim of this study was to compare the effects of the rehabilitation on patients with radius fracture at the typical site, who wore circumferential static wrist orthoses, with those who did not wear them. Methods. Thirty patients were divided into 3 equal groups, 2 experimental groups, and 1 control group. The patients in the experimental groups were given the rehabilitation program of wearing serially manufactured (off-the-shelf, as well as custom-fit orthoses. Those in the control group did not wear wrist orthoses. Evaluation parameters were pain, edema, the range of the wrist motion, the quality of cylindrical, spherical, and pinch-spherical grasp, the strength of pinch and hand grasp, and patient's assessment of the effects of rehabilitation. Results. No significant difference in the effects of rehabilitation on the patients in experimental groups as opposed to control group was found. Patients in the first experimental group, and in control group were more satisfied with the effects of rehabilitation, as opposed to the patients in the second experimental group (p<0,05. Conclusion. The effects of circumferential static wrist orthoses in the rehabilitation of patients with distal radius fracture at the typical site were not clinically significant. There was no significant difference between the custom and off-the-shelf orthoses.

  8. Open Reduction in Pediatric Condylar Fracture.

    Science.gov (United States)

    Barbosa, Alexandre Agostini; Mariano, Ronaldo Célio

    2017-05-01

    Facial fractures in children are rare. Lack of pneumatization, fat pockets, mixed dentition, contribute to the elasticity and bone stability. When mandibular fractures occur in children, most often involve the condyle by indirect trauma. Such fractures are the center of discussion on the form of treatment if this should be performed conservatively, or held the reduction and fixation of the fracture with surgical exposure of the fragments. In condylar fractures in children, in most patients, the proposed treatment is closed reduction. Treatment with open reduction and fixation has its specific indications. In this case, the authors report a patient cycling accident victim, with cut-contusion injury in ment with limited mouth opening and left condylar fracture with medial rotation. The treatment was the reduction and fixation of fragments by open process.

  9. Epidemiology of distal radius fractures in polytrauma patients and the influence of high traumatic energy transfer.

    Science.gov (United States)

    Ferree, Steven; van der Vliet, Quirine M J; Nawijn, Femke; Bhashyam, Abhiram R; Houwert, Roderick M; Leenen, Luke P H; Hietbrink, Falco

    2018-03-01

    For several extremity fractures differences in morphology, incidence rate and functional outcome were found when polytrauma patients were compared to patients with an isolated injury. This is not proven for distal radius fractures (DRF). Therefore, this study aimed to analyse fracture morphology in relation to energy transfer in both poly- and mono-trauma patients with a DRF. This was a retrospective cohort study. All patients aged 16 years and older with a DRF were included. Patients with an Injury Severity Score of 16 or higher were classified as polytrauma patients. Injuries were defined as high or low energy. All DRFs were classified using the AO/OTA fracture classification system. A total of 830 patients with a DRF were included, 12% were polytrauma. The incidence rate of DRF in polytrauma patients was 3.5%. Ipsilateral upper extremity injury was found in >30% of polytrauma and high-energy monotrauma patients, compared to 5% in low-energy monotrauma patients. More type C DRF were found in polytrauma and high-energy monotrauma patients versus low-energy monotrauma patients. Operative intervention rates for all types of DRF were similar for polytrauma and high-energy monotrauma patients. Non-union rates were higher in polytrauma patients. Higher energy mechanisms of injury, in polytrauma and high-energy monotrauma patients, were associated with more severe complex articular distal radius fractures and more ipsilateral upper extremity injuries. Polytrauma and high-energy monotrauma patient have a similar fracture morphology. However, polytrauma patients have in addition to more injured body regions also more non-union related interventions than high-energy monotrauma patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

    Science.gov (United States)

    Sinicropi, Stefano M; Su, Brian W; Raia, Frank J; Parisien, May; Strauch, Robert J; Rosenwasser, Melvin P

    2005-03-01

    Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

  11. The correlation of initial radiographic characteristics of distal radius fractures and injuries of the triangular fibrocartilage complex.

    Science.gov (United States)

    Kasapinova, K; Kamiloski, V

    2016-06-01

    Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. III. © The Author(s) 2016.

  12. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2012-01-01

    the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees.

  13. Mechanism of distal radius fracture as analyzed by 3D finite element model

    International Nuclear Information System (INIS)

    Tomizawa, Kazuo

    2007-01-01

    The purpose of this study is to see the difference of distal radius fracture between normal and osteoporotic bones and in its patterns due to limb position at injury through simulation and analysis of the biomechanics using three-dimensional (3D) finite element model. CT images were taken with SIEMENS machine, of right wrist joints of 32 and 76 years old, normal healthy man and osteoporotic woman, respectively. The wrist joint angles at CT were 70 degrees both at dorsiflexion and at palmerflexion for simulating fracture at tumbling down. The 3D bone model reconstructed from CT images with Forge software (Studio PON) was trimmed to remain the distal radial-ulnar portion and proximal carpal bones to make simulation easer, and the simplified 3D model was divided to 56,622 elements and 13,274 nodal points (normal bone) or 51,760 and 12,940 (osteoporosis), respectively, in 3 areas of different bone densities calculated with Scion Image processor. This 3D finite element model was analyzed with the software ANSYS LS-DYNA 10.0 for simulating the fracture (the defined yield stress attained) by impacting the elements of carpal bones to the radial bone joint surface with a measure of Mises stress. In osteoporotic bone, fracture was found to occur at dorsal cortex closer to the joint surface. Fracture occurred at dorsal and palmer cortex at dorsiflexion and palmerflexion, respectively. (R.T.)

  14. Distal radius fractures result in alterations in scapular kinematics: a three-dimensional motion analysis.

    Science.gov (United States)

    Ayhan, Cigdem; Turgut, Elif; Baltaci, Gul

    2015-03-01

    Scapular motion is closely integrated with arm motion. Injury to a distal segment requires compensatory changes in the proximal segments leading to alterations in scapular motion. Since the effects of distal injuries on scapular kinematics remain unknown, in the present study we investigated the influences on scapular motion in patients with distal injuries. Sixteen subjects with a history of distal radius fracture and 20 asymptomatic healthy subjects (controls) participated in the study. Three-dimensional scapular and humeral kinematic data were collected on all 3 planes of shoulder elevation: frontal, sagittal, and scapular. All testing was performed in a single session; therefore, the sensors remained attached to the participants for all testing. The position and orientation data of the scapula at 30°, 60°, 90°, and 120° humerothoracic elevation and 120°, 90°, 60°, and 30° lowering were used for statistical comparisons. Independent samples t-test was used to compare the scapular internal/external rotation, upward/downward rotation, and anterior/posterior tilt between the affected side of subjects with a distal radius fracture and the dominant side of asymptomatic subjects at the same stage of humerothoracic elevation. Scapular internal rotation was significantly increased at 30° elevation (P=0.01), 90° elevation (P=0.03), and 30° lowering (P=0.03), and upward rotation was increased at 30° and 60° elevation (Pplane elevation. Scapular upward rotation and anterior tilt were significantly increased during 30° lowering on both the scapular (P=0.002 and 0.02, respectively) and sagittal planes (P=0.01 and 0.02. respectively). Patients with distal radius fractures exhibit altered scapular kinematics, which may further contribute to the development of secondary musculoskeletal pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. [Treatment type C fracture of the distal radius with locking compression plate and external fixators].

    Science.gov (United States)

    Yang, Xiang; Zhao, You-ming; Chen, Lin; Ye, Cong-cong; Guo, Wei-jun; Wang, Bo

    2013-12-01

    To compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius. From January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up. Two cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,Pmeaning (t=-1.55, P>0.05). LCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.

  16. Trajectories in quality of life of patients with a fracture of the distal radius or ankle using latent class analysis

    NARCIS (Netherlands)

    van Son, M.A.C.; de Vries, J.; Zijlstra, W.; Roukema, J.A.; Gosens, T.; Verhofstad, M. H. J.; den Oudsten, B.L.

    2017-01-01

    Purpose This prospective study aimed to identify the different trajectories of quality of life (QOL) in patients with distal radius fractures (DRF) and ankle fractures (AF). Secondly, it was examined if subgroups could be characterized by sociodemographic, clinical, and psychological variables.

  17. Cross-education for improving strength and mobility after distal radius fractures: a randomized controlled trial.

    Science.gov (United States)

    Magnus, Charlene R A; Arnold, Cathy M; Johnston, Geoffrey; Dal-Bello Haas, Vanina; Basran, Jenny; Krentz, Joel R; Farthing, Jonathan P

    2013-07-01

    To evaluate the effects of cross-education (contralateral effect of unilateral strength training) during recovery from unilateral distal radius fractures on muscle strength, range of motion (ROM), and function. Randomized controlled trial (26-wk follow-up). Hospital, orthopedic fracture clinic. Women older than 50 years with a unilateral distal radius fracture. Fifty-one participants were randomized and 39 participants were included in the final data analysis. Participants were randomized to standard rehabilitation (Control) or standard rehabilitation plus strength training (Train). Standard rehabilitation included forearm casting for 40.4±6.2 days and hand exercises for the fractured extremity. Nonfractured hand strength training for the training group began immediately postfracture and was conducted at home 3 times/week for 26 weeks. The primary outcome measure was peak force (handgrip dynamometer). Secondary outcomes were ROM (flexion/extension; supination/pronation) via goniometer and the Patient Rated Wrist Evaluation questionnaire score for the fractured arm. For the fractured hand, the training group (17.3±7.4kg) was significantly stronger than the control group (11.8±5.8kg) at 12 weeks postfracture (P<.017). There were no significant strength differences between the training and control groups at 9 (12.5±8.2kg; 11.3±6.9kg) or 26 weeks (23.0±7.6kg; 19.6±5.5kg) postfracture, respectively. Fractured hand ROM showed that the training group had significantly improved wrist flexion/extension (100.5°±19.2°) than the control group (80.2°±18.7°) at 12 weeks postfracture (P<.017). There were no significant differences between the training and control groups for flexion/extension ROM at 9 (78.0°±20.7°; 81.7°±25.7°) or 26 weeks (104.4°±15.5°; 106.0°±26.5°) or supination/pronation ROM at 9 (153.9°±23.9°; 151.8°±33.0°), 12 (170.9°±9.3°; 156.7°±20.8°) or 26 weeks (169.4°±11.9°; 162.8°±18.1°), respectively. There were no

  18. Examination of Skill Acquisition and Grader Bias in a Distal Radius Fracture Fixation Model.

    Science.gov (United States)

    Putnam, Matthew D; Adams, Julie E; Lender, Paul; Van Heest, Ann E; Shanedling, Janet R; Nuckley, David J; Bechtold, Joan E

    2018-03-01

    Primary: Assess the ability of faculty graders to predict the objectively measured strength of distal radius fracture fixation. Secondary: Compare resident skill variation and retention related to other knowable training data. Residents were allowed 60 minutes to stabilize a standardized distal radius fracture using an assigned fixed-angle volar plate. Faculty observed and subjectively graded the residents without providing real-time feedback. Objective biomechanical evaluation (construct strength and stiffness) was compared to subjective grades. Resident-specific characteristics (sex, PGY, and ACGME case log) were also used to compare the objective data. A simulated operating room in our laboratory. Post-graduate year 2, 3, 4, and 5 orthopedic residents. Primary: Faculty were not successful at predicting objectively measured fixation, and their subjective scoring suggests confirmation bias as PGY increased. Secondary: Resident year-in-training alone did not predict objective measures (p = 0.53), but was predictive of subjective scores (p external faculty unfamiliar with tested residents, might alter these results. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  19. Arthroscopic knotless anchor repair of triangular fibrocartilage in distal radius fracture.

    Science.gov (United States)

    García-Ruano, Á A; Najarro-Cid, F; Jiménez-Martín, A; Gómez de los Infantes-Troncoso, J G; Sicre-González, M

    2015-01-01

    Lesions of triangular fibrocartilage (TFC) are associated with distal radioulnar joint instability. Arthroscopic treatment of these lesions improves functional outcome of affected patients. The aim of the present work is to evaluate functional and occupational outcome of TCF repair using an arthroscopic knotless anchor device in patients with associated distal radius fracture. An observational, descriptive study was carried out between November 2011 and January 2014 including 21 patients with distal radius fracture and Palmer 1B lesions of TCF (Atzei class 2 and 3) that were treated by arthroscopic knotless anchor (PopLok® 2,8mm, ConMed, USA). Mean follow-up was 18 months. Functional (Mayo Wrist Score) and occupational outcome results were analyzed. Mean age of the group was 43.0±8.8 years, with 19% of the patients being female. There was an associated scapholunate lesion in 5 cases. Functional results reached a mean of 83.4±16.1 points onMayo Wrist Score. Mean sick-leave time was 153.16±48.5 days. Complete occupational reintegration was reached in 89.5% of cases. There were no postoperative complications. Arthroscopic knotless anchor repair of 1B TFC tears is a minimally invasive method of treatment that improves tension of fixation, avoiding subsequent loosen, in our experience, with few complications and good functional and occupational results. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Bone strength and muscle properties in postmenopausal women with and without a recent distal radius fracture.

    Science.gov (United States)

    Crockett, K; Arnold, C M; Farthing, J P; Chilibeck, P D; Johnston, J D; Bath, B; Baxter-Jones, A D G; Kontulainen, S A

    2015-10-01

    Distal radius (wrist) fracture (DRF) in women over age 50 years is an early sign of bone fragility. Women with a recent DRF compared to women without DRF demonstrated lower bone strength, muscle density, and strength, but no difference in dual-energy x-ray absorptiometry (DXA) measures, suggesting DXA alone may not be a sufficient predictor for DRF risk. The objective of this study was to investigate differences in bone and muscle properties between women with and without a recent DRF. One hundred sixty-six postmenopausal women (50-78 years) were recruited. Participants were excluded if they had taken bone-altering medications in the past 6 months or had medical conditions that severely affected daily living or the upper extremity. Seventy-seven age-matched women with a fracture in the past 6-24 months (Fx, n = 32) and without fracture (NFx, n = 45) were measured for bone and muscle properties using the nondominant (NFx) or non-fractured limb (Fx). Peripheral quantitative computed tomography (pQCT) was used to estimate bone strength in compression (BSIc) at the distal radius and tibia, bone strength in torsion (SSIp) at the shaft sites, muscle density, and area at the forearm and lower leg. Areal bone mineral density at the ultradistal forearm, spine, and femoral neck was measured by DXA. Grip strength and the 30-s chair stand test were used as estimates of upper and lower extremity muscle strength. Limb-specific between-group differences were compared using multivariate analysis of variance (MANOVA). There was a significant group difference (p lower leg, with the Fx group demonstrating 16 and 19% lower BSIc, 3 and 6% lower muscle density, and 20 and 21% lower muscle strength at the upper and lower extremities, respectively. There were no differences between groups for DXA measures. Women with recent DRF had lower pQCT-derived estimated bone strength at the distal radius and tibia and lower muscle density and strength at both extremities.

  1. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  2. Effect of facility on the operative costs of distal radius fractures.

    Science.gov (United States)

    Mather, Richard C; Wysocki, Robert W; Mack Aldridge, J; Pietrobon, Ricardo; Nunley, James A

    2011-07-01

    The purpose of this study was to investigate whether ambulatory surgery centers can deliver lower-cost care and to identify sources of those cost savings. We performed a cost identification analysis of outpatient volar plating for closed distal radius fractures at a single academic medical center. Multiple costs and time measures were taken from an internal database of 130 consecutive patients and were compared by venue of treatment, either an inpatient facility or an ambulatory, stand-alone surgery facility. The relationships between total cost and operative time and multiple variables, including fracture severity, patient age, gender, comorbidities, use of bone graft, concurrent carpal tunnel release, and surgeon experience, were examined, using multivariate analysis and regression modeling to identify other cost drivers or explanatory variables. The mean operative cost was considerably greater at the inpatient facility ($7,640) than at the outpatient facility ($5,220). Cost drivers of this difference were anesthesia services, post-anesthesia care unit, and operating room costs. Total surgical time, nursing time, set-up, and operative times were 33%, 109%, 105%, and 35% longer, respectively, at the inpatient facility. There was no significant difference between facilities for the additional variables, and none of those variables independently affected cost or operative time. The only predictor of cost and time was facility type. This study supports the use of ambulatory stand-alone surgical facilities to achieve efficient resource utilization in the operative treatment of distal radius fractures. We also identified several specific costs and time measurements that differed between facilities, which can serve as potential targets for tertiary facilities to improve utilization. Economic and Decisional Analysis III. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    International Nuclear Information System (INIS)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E.

    2016-01-01

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  4. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E. [University Medical Center Freiburg, Department of Radiology, Freiburg (Germany)

    2016-12-15

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  5. The prevalence of pain and disability one year post fracture of the distal radius in a UK population: A cross sectional survey

    Directory of Open Access Journals (Sweden)

    Leonardi-Bee Jo

    2008-09-01

    Full Text Available Abstract Background A fracture of the distal radius is a commonly occurring fracture and accounts for a third of all fractures in the elderly. Thus far, one year estimates of pain and disability following a fracture of the distal radius have been reported on Canadian populations. The primary aim of this study is to investigate the prevalence of pain and disability in a UK population one year post fracture of the distal radius. Methods A cross-sectional survey was undertaken, of all subjects suffering a fracture of the distal radius between October 2005 and February 2006 in Nottingham, UK. Primary outcomes used were the VAS for pain and the DASH for disability. Prevalence of pain and disability were calculated and odds ratios presented for associations between demographics, pain and disability. Results 93/264 (35% subjects responded to the questionnaire. 6 subjects did not fulfill the inclusion criteria and were excluded from further analysis. 11% of subjects reported moderate to very severe pain. 16% of subjects reported moderate to very severe disability. Statistically significant associations were found between pain medication usage for the wrist fracture and moderate to very severe pain (OR 11.20, 95% CI 2.05 – 61.23. Moderate to very severe disability was associated with older age (OR 6.53, 95%CI 1.65 – 25.90 and pain medication usage for the wrist fracture (OR 4.75, 95% CI 1.38 – 16.37. Working was associated with a reduction in risk of moderate to very severe disability (OR 0.14, 95% CI 0.03 – 0.67. Conclusion This study demonstrates that there are a small proportion of patients who are still suffering moderate to very severe pain and disability one year post fracture of the distal radius. The study also demonstrates that there are significant associations between characteristics of the patients and the level of pain and disability. This highlights the need for further research into the most appropriate management of these patients

  6. Ipsilateral dislocation of the radial head associated with fracture of distal end of the radius: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Gupta Vinay

    2013-06-01

    Full Text Available 【Abstract】Dislocation of the radial head in adults is uncommon. A simultaneous dislocation of the radial head and fracture of the ipsilateral distal end of radius with no other associated injuries is extremely rare. As far as we know, such an injury after an unusual mode of injury has been seldom reported in the English literature. We report such a case without any associated injuries or comorbidity. Closed reduction was performed within two hours after injury and results were satisfactory. Immobilisation was continued for 3 weeks. Gradual mobilisation was started after removal of the plaster under the supervision of a physiotherapist. At 6 months’ follow-up, the patient had no residual pain at the elbow with full flexion & extension. Almost full supination with a restriction of last 10 degrees of pronation was achieved. There was no evidence of instability of the elbow. Key words: Radial heads; Dislocations; Radius fractures

  7. A new building block: costo-osteochondral graft for intra-articular incongruity after distal radius fracture.

    Science.gov (United States)

    Tang, Chris Yuk Kwan; Fung, Boris; Poon, T L; Fok, Margaret

    2014-01-01

    Even with the invention of locking plates, intra-articular fractures of distal radius with extreme comminution remain a challenge for orthopaedic surgeons. Osteochondral graft is a potential choice to reconstruct the articular defect. We report a patient who had a fracture of distal radius with costo-osteochondral graft for articular reconstruction which has not yet been described in the English literature. At nine-year follow-up, he was pain free and had full range of movement of the wrist. The authors suggest that costo-osteochondral graft could be an option with satisfactory result.

  8. The effect of search term on the quality and accuracy of online information regarding distal radius fractures.

    Science.gov (United States)

    Dy, Christopher J; Taylor, Samuel A; Patel, Ronak M; Kitay, Alison; Roberts, Timothy R; Daluiski, Aaron

    2012-09-01

    Recent emphasis on shared decision making and patient-centered research has increased the importance of patient education and health literacy. The internet is rapidly growing as a source of self-education for patients. However, concern exists over the quality, accuracy, and readability of the information. Our objective was to determine whether the quality, accuracy, and readability of information online about distal radius fractures vary with the search term. This was a prospective evaluation of 3 search engines using 3 different search terms of varying sophistication ("distal radius fracture," "wrist fracture," and "broken wrist"). We evaluated 70 unique Web sites for quality, accuracy, and readability. We used comparative statistics to determine whether the search term affected the quality, accuracy, and readability of the Web sites found. Three orthopedic surgeons independently gauged quality and accuracy of information using a set of predetermined scoring criteria. We evaluated the readability of the Web site using the Fleisch-Kincaid score for reading grade level. There were significant differences in the quality, accuracy, and readability of information found, depending on the search term. We found higher quality and accuracy resulted from the search term "distal radius fracture," particularly compared with Web sites resulting from the term "broken wrist." The reading level was higher than recommended in 65 of the 70 Web sites and was significantly higher when searching with "distal radius fracture" than "wrist fracture" or "broken wrist." There was no correlation between Web site reading level and quality or accuracy. The readability of information about distal radius fractures in most Web sites was higher than the recommended reading level for the general public. The quality and accuracy of the information found significantly varied with the sophistication of the search term used. Physicians, professional societies, and search engines should consider

  9. Clinical and functional outcome of open primary repair of triangular fibrocartilage complex tears associated with distal radius fractures.

    Science.gov (United States)

    Johandi, Faisal; Sechachalam, Sreedharan

    2017-01-01

    We evaluate the clinical and functional outcome of open primary repair of acute TFCC tears in distal radius fracture, when there is gross intraoperative distal radioulnar joint (DRUJ) instability after fixation of the distal radius, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed. A retrospective review of our institution's distal radius fracture database over a 4-year period (January 2010 to December 2013). A total of 12 (1.38%) out of 3379 patients had an open TFCC repair in the same setting as fixation of distal radius. Assessment of outcome involved the analysis of objective and subjective clinical and functional outcomes. All patient regained Activities of Daily Living (ADL) independence; eleven out of 12 patients (91.7%) returned to pre-injury function and 8 out of 11 patients (72.7%) returned to their jobs. DRUJ stability was preserved in 10 patients (83.3%) with 10 patients (83.3%) having grip strength of at least 50%, compared to the uninjured hand, and 7 (58.3%) with grip strength of more than or equal to 75%. Complications of surgery identified can be classified into 4 broad categories: infection, neurological complications, persistent DRUJ instability and prolonged pain. The authors believe a primary open repair of the TFCC should be considered when patients present with instability during intra-operative DRUJ ballottement test after distal radius fixation, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed.

  10. The art of trochanteric fracture reduction.

    Science.gov (United States)

    Biber, Roland; Berger, Johanna; Bail, Hermann Josef

    2016-12-01

    The name of Ender is primarily associated with the Ender nails, which were popular for trochanteric fracture fixation more than thirty years ago. However, Ender's concepts were not limited to the implant. Ender developed a unique classification system for trochanteric and subtrochanteric fractures, which provided the theory for closed reduction maneuvers that made the method so successful in his hands. While Ender's nails have become history in the meantime, his principles of fracture reduction can be readily applied on surgery with modern implants such as proximal femoral nails. This article reflects the classification and the principles published by Hans Georg Ender in some print work hardly available nowadays. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    Science.gov (United States)

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    Science.gov (United States)

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P0.05). The effective rate of swelling regression in electrical physical therapy group, western medicine group and the control group were 86.67%, 80.00%, 46.66% respectively. There was no

  13. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  14. Patterns of triangular fibrocartilage complex (TFCC) injury associated with severely dorsally displaced extra-articular distal radius fractures.

    Science.gov (United States)

    Scheer, Johan H; Adolfsson, Lars E

    2012-06-01

    The aim of the study was to examine triangular fibrocartilage (TFCC) injury patterns associated with unstable, extra-articular dorsally displaced distal radius fractures. Twenty adult patients with an Arbeitsgemeinschaft für Osteosynthesefragen (AO), type A2 or A3, distal radius fracture with an initial dorsal angulation greater than 20° were included. Nine had a tip fracture (distal to the base) of the ulnar styloid and 11 had no such fracture. They were all openly explored from an ulnopalmar approach and TFCC injuries were documented. Eleven patients also underwent arthroscopy and intra-articular pathology was recorded. All patients had TFCC lesions of varying severity, having an extensor carpi ulnaris subsheath avulsion in common. Eighteen out of 20 also displayed deep foveal radioulnar ligament lesions, with decreasingly dorsal fibres remaining. The extent of this foveal injury could not be appreciated by radiocarpal arthroscopy. Severe displacement of an extra-articular radius fracture suggests an ulnar-sided ligament injury to the TFCC. The observed lesions concur with findings in a previous cadaver study. The lesions follow a distinct pattern affecting both radioulnar as well as ulnocarpal stabilisers. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Complaints in the follow-up of conservatively treated distal radius fractures - predictors in the initial radiograph

    International Nuclear Information System (INIS)

    Freund, W.; Aschoff, A.J.; Einsiedel, T.; Kramer, M.; Trnavac, S.; Bezirkskrankenhaus Guenzburg

    2007-01-01

    Purpose: Radius fractures are frequent in adults, and the long-term results of conservative treatment remain disappointing. This study examines predictors for the clinical outcome in the initial radiograph. This will help to identify patients who will benefit from surgical treatment. Materials and Methods: A cohort study including a standardized telephone interview (Cooney score) was used to identify all conservatively treated patients with a distal radius fracture over a five-year period. The additional selection criteria were: over 15 years old, initial X-ray available, patient reachable by phone for the follow-up interview. The following measurements were taken from the initial radiograph: Radius-base angle, radial shortening, radiopalmar angle and intraarticular displacement. Correlations and a simple test to predict negative outcome were computed. Results: Of the initially identified 2211 patients with distal radius fracture, 179 also fulfilled the other criteria. The patients were 56.2 years old on average (standard deviation SD = ± 22.45 years) and 72 % were female. 60 % of the fractures were on the right side. The average follow-up was 4.3 years (SD ± 1.66). The Cooney score results averaged 85 points (with 100 being the optimal and maximum score), indicating good or very good functional results in the long term follow-up for 61 % of patients. However, 31 % received a rating of fair or poor and therefore had an unfavorable outcome. With respect to the correlations, age and shortening of the radius (but not gender) had a significant influence on the functional result. Using an age of 75 years or above and a radial shortening of at least 4 mm to predict an unfavorable outcome, the sensitivity is only 16 %, but the positive predictive value is 73 % and the specificity is 96 %. (orig.)

  16. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Science.gov (United States)

    Harris, Jocelyn E; MacDermid, Joy C; Roth, James

    2005-01-01

    Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE), The Wrist Outcome Measure (WOM), and the Medical Outcome Survey Short-Form (SF-36) were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week) and 33% (three months) of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months) and 8% (one year). Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture. PMID:16288664

  17. The International Classification of Functioning as an explanatory model of health after distal radius fracture: A cohort study

    Directory of Open Access Journals (Sweden)

    MacDermid Joy C

    2005-11-01

    Full Text Available Abstract Background Distal radius fractures are common injuries that have an increasing impact on health across the lifespan. The purpose of this study was to identify health impacts in body structure/function, activity, and participation at baseline and follow-up, to determine whether they support the ICF model of health. Methods This is a prospective cohort study of 790 individuals who were assessed at 1 week, 3 months, and 1 year post injury. The Patient Rated Wrist Evaluation (PRWE, The Wrist Outcome Measure (WOM, and the Medical Outcome Survey Short-Form (SF-36 were used to measure impairment, activity, participation, and health. Multiple regression was used to develop explanatory models of health outcome. Results Regression analysis showed that the PRWE explained between 13% (one week and 33% (three months of the SF-36 Physical Component Summary Scores with pain, activities and participation subscales showing dominant effects at different stages of recovery. PRWE scores were less related to Mental Component Summary Scores, 10% (three months and 8% (one year. Wrist impairment scores were less powerful predictors of health status than the PRWE. Conclusion The ICF is an informative model for examining distal radius fracture. Difficulty in the domains of activity and participation were able to explain a significant portion of physical health. Post-fracture rehabilitation and outcome assessments should extend beyond physical impairment to insure comprehensive treatment to individuals with distal radius fracture.

  18. Factors in secondary prevention subsequent to distal radius fracture : Focus on physical function, co-morbidity, bone mineral density and health-related quality of life

    OpenAIRE

    Nordvall, Helena

    2009-01-01

    In Sweden approximately 25000 distal radius fractures occur annually, which is 37 % of all fractures related to osteoporosis. In this thesis, risk factors for osteoporosis, bone mineral density (BMD) and health-related quality of life (the SF-36) were compared in patients who suffered a distal radius fracture after low energy trauma with a control group matched on the basis of age, gender, and municipality of residence. The aim was also to analyse, among these patients, whether a risk factor ...

  19. Association of Insulin-like Growth Factor-1, Bone Mass and Inflammation to Low-energy Distal Radius Fractures and Fracture Healing in Elderly Women Attending Emergency Care.

    Science.gov (United States)

    Chisalita, Simona I; Chong, Lee Ti; Wajda, Maciej; Adolfsson, Lars; Woisetschläger, Mischa; Spångeus, Anna

    2017-11-01

    Elderly patients suffer fractures through low-energy mechanisms. The distal radius is the most frequent fracture localization. Insulin-like growth factor-1 (IGF1) plays an important role in the maintenance of bone mass and its levels decline with advancing age and in states of malnutrition. Our aim was to investigate the association of IGF1 levels, bone mass, nutritional status, and inflammation to low-energy distal radius fractures and also study if fracture healing is influenced by IGF1, nutritional status, and inflammation. Postmenopausal women, 55 years or older, with low-energy distal radius fractures occurring due to falling on slippery ground, indoors or outdoors, were recruited in the emergency department (ED) and followed 1 and 5 weeks after the initial trauma with biomarkers for nutritional status and inflammation. Fractures were diagnosed according to standard procedure by physical examination and X-ray. All patients were conservatively treated with plaster casts in the ED. Patients who needed interventions were excluded from our study. Fracture healing was evaluated from radiographs. Fracture healing assessment was made with a five-point scale where the radiological assessment included callus formation, fracture line, and stage of union. Blood samples were taken within 24 h after fracture and analyzed in the routine laboratory. Bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry (DXA). Thirty-eight Caucasian women, aged 70.5 ± 8.9 years (mean ± SD) old, were recruited. Nutritional status, as evaluated by albumin (40.3 ± 3.1 g/L), IGF1 (125.3 ± 39.9 μg/L), body mass index (26.9 ± 3.6 kg/m 2 ), arm diameter (28.9 ± 8.9 cm), and arm skinfold (2.5 ± 0.7 cm), was normal. A positive correlation was found between IGF1 at visit 1 and the lowest BMD for hip, spine, or radius (r = 0.39, P = 0.04). High sensitive C-reactive protein (hsCRP) and leukocytes were higher at the fracture event compared to 5 weeks later (P = 0.07 and P

  20. New quantitative ultrasound techniques for bone analysis at the distal radius in hip fracture cases: differences between femoral neck and trochanteric fractures.

    Science.gov (United States)

    Horii, Motoyuki; Fujiwara, Hiroyoshi; Sakai, Ryo; Sawada, Koshiro; Mikami, Yasuo; Toyama, Syogo; Ozaki, Etsuko; Kuriyama, Nagato; Kurokawa, Masao; Kubo, Toshikazu

    2017-01-01

    Ample evidence on etiological and pathological differences between femoral neck and trochanteric fracture cases suggests the possibility of individualized treatment. There are many issues related to areal bone mineral density and other quantitative computed tomography parameters of the proximal femur. Although osteoporosis is a systemic problem, little has been reported regarding differences in bone structural parameters, including bone mineral density, between them in regions other than the proximal femur. Participants were consecutive female patients >50 years of age admitted to the Saiseikai Suita Hospital (Osaka prefecture, Japan) for their first hip fracture between January 2012 and September 2014. Cortical thickness (CoTh, mm), volumetric trabecular bone mineral density (TBD, mg/cm 3 ), and elastic modulus of trabecular bone (EMTb, GPa) were obtained as the new QUS parameters using the LD-100 system (Oyo Electric, Kyoto, Japan). The mean values of these parameters were compared between femoral neck and trochanteric fracture cases. In addition, correlations between age and each QUS parameter were investigated for each fracture type. A receiver operating characteristic (ROC) curve analysis was performed to examine the degree of effect each parameter on the fracture types. The area under the curve (AUC) for each parameter was compared to the AUC for age. There were 63 cases of femoral neck fracture (mean age, 78.2 years) and 37 cases of trochanteric fracture (mean age, 85.9 years). Mean TBD and EMTb were significantly higher for femoral neck fractures. There were significant negative correlations between QUS parameters and age for femoral neck fractures (P fractures were above those for trochanteric fractures for TBD and EMTb. AUCs were 0.72 for age, and 0.61, 0.65, and 0.65 for CoTh, TBD, and EMTb, respectively. The new QUS parameters indicated that TR fracture cases were more osteoporotic than were FN fracture cases, even at the distal radius. There might be

  1. Open segmental fracture of both bone forearm and dislocation of ipsilateral elbow with extruded middle segment radius

    Directory of Open Access Journals (Sweden)

    Pawan Kumar

    2013-01-01

    Full Text Available Extruded middle segment of radius with open segmental fracture both bone forearm and dislocation of ipsilateral elbow is a rare injury. A 12-year-old child presented to us within 4 hours following fall from tree. The child′s mother was carrying a 12-cm-long extruded soiled segment of radius. The extruded bone was thoroughly washed. The medullary cavity was properly syringed with antiseptic solution. The bone was autoclaved and put in the muscle plane of the distal forearm after debridement of the wound. After 5 days, a 2.5-mm K-wire was introduced by retrograde method into the proximal radius by passing through the extruded segment. Another 2.5-mm K-wire was passed in ulna. The limb was evaluated clinicoradiologically every 2 weeks. The wound was healed by primary intention. At 4 months, the reposed bone appeared less dense radiologically and K-wire seemed to be out of the bone. In the subsequent months, the roentgenograms show remodeling of the extruded fragment. After 20 weeks, the K-wires were removed (first ulnar and then radial. Complete union was achieved with full range of movement except loss of few degrees of extension of elbow and thumb. This case is reported to show a good outcome following successful incorporation of an extruded segment of radius in an open fracture.

  2. Radiological dorsal tilt analysis of AO type A, B, and C fractures of the distal radius treated conservatively or with extra-focal K-wire plus external fixateur

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Michael [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Borders General Hospital, Department for Trauma and Orthopaedic Surgery, Melrose, Roxburghshire, Scotland (United Kingdom); Schroeder, Malte; Gruber-Rathmann, Michaela; Ruecker, Andreas H. [University Medical Center Hamburg-Eppendorf, Department of Trauma, Hand and Reconstructive Surgery, Hamburg (Germany); Kossow, Kai [Department of Medical Psychology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2012-09-15

    Fractures of the distal radius are amongst the most common injury patterns. The dorsal tilt represents an important co-factor determining functional outcome. The purpose of this study was to analyze the radiological dorsal tilt and identify critical time frames in conservative and operative treatment of distal radius fractures. Eighty-seven conservatively treated (hematoma block assisted reduction and splinting) and 37 operatively treated (reduction, extra-focal K-wire fixation, bridging external fixateur) AO type A, B, and C fractures of the distal radius in 124 females were retrospectively analyzed. The dorsal tilt at the initial, post-reduction, and 2 weeks post-reduction stages was correlated with the final radiographic outcome at 6 weeks. Mean initial dorsal tilt was 16.53 in the conservatively treated group and 26.76 in the operatively treated group. Mean dorsal tilt after 6 weeks showed significant differences from the mean initial dorsal tilt at time of presentation within both groups (both groups p < 0.000). No significant differences between the two groups were found after 6 weeks of treatment (p = 0.194) regardless of the underlying AO fracture type. Conservatively treated radius fractures showed a significantly higher slip rate within the first 2 weeks (primary slip rate), whereas the operative group presented a significantly higher slip rate between the 2-week and 6-week radiographic checks (secondary slip rate). In terms of dorsal tilt, conservative (cast immobilization) and operative (K-wire fixation plus external fixateur) treatment demonstrated no significant differences at the final radiographic examination (6 weeks) regardless of the underlying AO fracture type. Both treatment groups showed treatment-associated different primary and secondary slip rates, indicating a need for more frequent radiographic checks within these critical time frames. (orig.)

  3. Testing the validity of preventing chronic regional pain syndrome with vitamin C after distal radius fracture. [Corrected].

    Science.gov (United States)

    Malay, Sunitha; Chung, Kevin C

    2014-11-01

    The American Academy of Orthopaedic Surgeons recommends the use of vitamin C to prevent complex regional pain syndrome (CRPS) for patients with distal radius fractures (DRFs). We hypothesized that the evidence for supporting this recommendation is weak, based on epidemiological principles of association and causality. The specific aim of this project was to test the validity of this recommendation. We conducted a literature review to retrieve articles reporting on the use of vitamin C to prevent CRPS. Data collected included sample size, study design type, dose of vitamin C used, and outcome measures of association expressed as relative risk (RR) and odds ratio. We then applied Hill criteria to evaluate the relationship between vitamin C and CRPS. We obtained 225 articles from the database search. After the exclusion of duplicates, unrelated articles, editorial letters, and commentaries, we found 4 articles and 1 systematic review relevant to our topic. Six of the 9 Hill criteria were met, and an earlier meta-analysis showed a quantified reduction in CRPS risk. However, criteria like biological plausibility, specificity, and coherence were not met. The number of causal/association criteria met was adequate to support the scientific premise of the effect of vitamin C in preventing CRPS after DRF. Furthermore, vitamin C administration is of relatively low cost and has few complications unless administered in large doses. Owing to sufficient epidemiological evidence availability, the American Academy of Orthopaedic Surgeons recommendation of vitamin C to prevent CRPS has practical merit. Therapeutic II. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Midterm Follow-up of Treating Volar Marginal Rim Fractures with Variable Angle Lcp Volar Rim Distal Radius Plates.

    Science.gov (United States)

    Goorens, Chul Ki; Geeurickx, Stijn; Wernaers, Pascal; Staelens, Barbara; Scheerlinck, Thierry; Goubau, Jean

    2017-06-01

    Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. The female to male ratio was 5:5 and the mean age was 52.2 (range, 17-80) years. The mean follow-up period was 11 (range, 5-19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100-180°) compared to the contralateral uninjured side 160° (range, 95-180°). The mean total pronation/supination range was 153° (range, 140-180°) compared to the contralateral uninjured side 170° (range, 155-180°). Mean grip strength was 14 kg (range, 9-22), compared to the contralateral uninjured side 20 kg (range, 12-25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0-34.1), while post-recovery QuickDASH was 25 (range 0-43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating

  5. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR “DIE PUNCH” DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2015-01-01

    Objective: the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. Methods: There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. Results: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. Conclusion: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. PMID:27027079

  6. [Clinical observation on the effect of joint mobilization in treating elderly patients after distal radius fractures operation].

    Science.gov (United States)

    Jia, Xue-Feng; Cai, Hong-Xin; Lin, Ge-Sheng; Fang, Ji-Shi; Wang, Yong; Wu, Zhi-Yong; Tu, Xu-Hui

    2017-07-25

    To investigate the effect of joint mobilization on postoperative wrist joint function, pain and grip strength for elderly patients with distal radius fracture. From January 2015 to June 2016, a total of 67 elderly patients with distal radius fracture were randomly divided into routine exercise group and joint mobilization group. Among them, 37 patients in the routine exercise group underwent conventional distal radius fracture postoperative joint function exercise regimen, including 16 males and 21 females with a mean age of (67.8±3.2) years old ranging from 60 to 72 years old;the injured side was dominant in 23 cases and non-dominant in 14 cases;injury mechanism was fall in 26 cases, traffic accident in 11 cases; for AO type, 6 cases were type B3, 18 cases were type C1, 7 cases were type C2, 6 cases was type C3. Other 30 patients in the joint mobilization group underwent joint mobilization on the basis of the routine exercise group including 14 males and 16 females with a mean age of (67.1±4.0) years old ranging from 61 to 74 years old; the injured side was dominant in 21 cases and non-dominant in 9 cases;injury mechanism was fall in 25 cases, traffic accident in 5 cases;for AO type, 8 cases were type B3, 13 cases were type C1, 6 cases were type C2, 9 cases were type C3. The wrist joint activity, Gartland-Werley wrist joint function score, VAS pain score and grip strength were observed at 3 months afrer treatment. After 3 months' treatment, the VAS in the routine exercise group was higher than that of the joint mobilization group ( P joint mobilization group was higher than that in routine exercise group( P joint mobilization group( P joint mobilization group had no significant difference ( P >0.05). In the comparison of each item of Gartland-Werley, there was no significant difference between two groups in residual deformity and complication( P >0.05); the average score of subjective score, objective score and total score in routine exercise group were

  7. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  8. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    OpenAIRE

    Choi, Kang-Young; Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and de...

  9. Influence of side-groove root radius on the ductile fracture toughness of miniature C(T) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.

    2009-05-15

    The use of miniature C(T) specimens, MC(T), for fracture toughness measurements in the upper shelf regime has been investigated at SCK-CEN since 2004, in the framework of the Electrabel/Tractebel SCK-CEN Convention (now General Framework Agreement SUEZ-SCK-CEN). This geometry has been used and validated on both unirradiated (2004-05) and irradiated (2006) materials, mainly reactor pressure vessel (RPV) steels. While side-grooved MC(T) specimens have shown in all conditions a systematically lower tearing resistance and ductile crack initiation toughness as compared to standard-size 1TC(T) samples, the only plain-sided MC(T) specimen tested in 2005 exhibited very high ductile fracture toughness, thus pointing at a strong influence of side-grooving on the upper shelf properties of MC(T) specimens. This study investigates the influence of side-grooving on the initiation toughness and tearing resistance of MC(T) specimens, as a function of the root radius of the side-groove (ranging from 0.1 to 1 mm) and in comparison with plain-sided MC(T) and reference 1TC(T) samples. The material used is the well characterized DIN 22NiMoCr37 RPV steel, which had been used in the European project which generated the famous EURO fracture toughness data set.

  10. FUNCTIONAL RECOVERY AFTER MINIMALLY INVASIVE OSTEOSYNTHESIS IN FRACTURES OF THE SHAFT OF THE RADIUS AND ULNA

    Directory of Open Access Journals (Sweden)

    A. N. Chelnokov

    2016-01-01

    Full Text Available Introduction. Closed intramedullary nailing and external fixation are minimally invasive treatment options in radial and ulnar shaft fractures. We found no comparative studies of these methods in the current literature. Objective. A comparative analysis of both methods in radial and ulnar shaft fractures treated by closed intramedullary nailing and external fixation. Material and methods. 63 patients with forearm shaft fractures treated by closed intramedullary nailing (group I; 24 patients treated by external fixation (group II. All patients were operated within 30 days after injury. Postoperatively, all patients were evaluated clinically (range of motion of elbow and wrist, rotation of the forearm and radiologically. Disability of the Arm, Shoulder and Hand (DASH score was used to assess the functional status and quality of life. Results. The average time of radiological bone union in the group I and group II was 12,6 ± 1,4 weeks. and 12,7 ± 0,6 weeks, accordingly. Statistically significant differences in range of motion in the elbow and wrist occurred in 1 month after the surgery with the advantage in Group I. Restoration of rotation was faster in Group I up to 1 year after surgery. DASH scores in 2 month after the surgery were 11,2±1,96 in the nailing group (as in healthy population and 45,2±6,7 in the external fixation group. In 6 months after surgery the subjective assessment of the quality of life did not differ in both groups. Conclusion. Both minimally invasive methods of surgical stabilization provide restoration of anatomy of the forearm and complete functional recovery in final outcome, but closed intramedullary nailing results with significantly more rapid restoration of range of motions and quality of life measures.

  11. Does fluoroscopy improve outcomes in paediatric forearm fracture reduction?

    International Nuclear Information System (INIS)

    Menachem, S.; Sharfman, Z.T.; Perets, I.; Arami, A.; Eyal, G.; Drexler, M.; Chechik, O.

    2016-01-01

    Aim: To compare the radiographic results of paediatric forearm fracture reduced with and without fluoroscopic enhancement to investigate whether fractures reduced under fluoroscopic guidance would have smaller residual deformities and lower rates of re-reduction and surgery. Materials and methods: A retrospective cohort analysis was conducted comparing paediatric patients with acute forearm fracture in two trauma centres. Demographics and radiographic data from paediatric forearm fractures treated in Trauma Centre A with the aid of a C-arm fluoroscopy were compared to those treated without fluoroscopy in Trauma Centre B. Re-reduction, late displacement, post-reduction deformity, and need for surgical intervention were compared between the two groups. Results: The cohort included 229 children (175 boys and 54 girls, mean age 9.41±3.2 years, range 1–16 years) with unilateral forearm fractures (83 manipulated with fluoroscopy and 146 without). Thirty-four (15%) children underwent re-reduction procedures in the emergency department. Fifty-three (23%) children had secondary displacement in the cast, of which 18 were operated on, 20 were re-manipulated, and the remaining 15 were kept in the cast with an acceptable deformity. Twenty-nine additional children underwent operation for reasons other than secondary displacement. There were no significant differences in re-reduction and surgery rates or in post-reduction deformities between the two groups. Conclusion: The use of fluoroscopy during reduction of forearm fractures in the paediatric population apparently does not have a significant effect on patient outcomes. Reductions performed without fluoroscopy were comparably accurate in correcting deformities in both coronal and sagittal planes. - Highlights: • Compared outcomes of pediatric forearm fracture reduction with and without fluoroscopy. • The use of fluoroscopy during reduction of forearm fractures in the pediatric population apparently does not have a

  12. Cuttable plate fixation for small breed dogs with radius and ulna fractures: Retrospective study of 31 dogs.

    Science.gov (United States)

    Watrous, Gwyneth K; Moens, Noel M M

    2017-04-01

    This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.

  13. Effects of root radius, stress, crack growth and rate on fracture instability

    Energy Technology Data Exchange (ETDEWEB)

    McClintock, F A

    1965-01-01

    Of various criteria for fracture at the root of a notch, the energy, local stress, and displacement criteria have limited validity. More appropriate is the history of both stress and strain over a small region ahead of the crack, as required for fracture by the coalescence of holes. Expressions are given for crack initiation, growth, and subsequent instability in anti-plane strain of a nonhardening material. Instability is shown to depend primarily on those strain increments arising from crack growth at constant load rather than on those from increasing load at constant crack length. Thus final instability conditions are similar for single and double- ended cracks, round notches, and cracks cut under constant load. Round notches may give instability, restabilization and final instability. The growth and coalescence of holes in front of a crack in a linearly viscous material is studied for both tensile and anti-plant-strain cracks. The absence of residual strain eliminates instability, but the crack continually accelerates. (26 refs.)

  14. Changes in Depression, Health Anxiety, and Pain Catastrophizing Between Enrollment and 1 Month After a Radius Fracture.

    Science.gov (United States)

    Golkari, Sina; Teunis, Teun; Ring, David; Vranceanu, Ana-Maria

    2015-01-01

    To test the difference in symptoms of (1) depression, (2) health anxiety, and (3) catastrophic thinking between 1 and 6 weeks after injury to the radius. In total, 69 adult patients with a minimally displaced radial head or distal radius fracture were prospectively enrolled. After diagnosis, we recorded demographic variables, 11-point ordinal numerical pain score, and agreement with "no pain, no gain"; Disabilities of the Arms, Shoulder, and Hand (DASH) questionnaire; Center for Epidemiologic Studies Depression Scale; the Whiteley Index; and the Pain Catastrophizing Scale. In total, 55 patients (80%) returned after 1 month to reevaluate pain, Disabilities of the Arms, Shoulder, and Hand, Center for Epidemiologic Studies Depression, Whiteley Index, and Pain Catastrophizing Scale scores. Center for Epidemiologic Studies Depression scores decreased by an average of 5 ± 9 points (p psychologic measures are used as a screening tool to predict outcome after treatment, one should account for a patient's disease phase. Prognostic level I. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  15. Effect of finite edge radius on ductile fracture ahead of the cutting tool edge in micro-cutting of Al2024-T3

    International Nuclear Information System (INIS)

    Subbiah, Sathyan; Melkote, Shreyes N.

    2008-01-01

    Evidence of ductile fracture leading to material separation has been reported recently in ductile metal cutting [S. Subbiah, S.N. Melkote, ASME J. Manuf. Sci. Eng. 28(3) (2006)]. This paper investigates the effect of finite edge radius on such ductile fracture. The basic question of whether such ductile fracture occurs in the presence of a finite edge radius is explored by performing a series of experiments with inserts of different edge radii at various uncut chip thickness values ranging from 15 to 105 μm. Chip-roots are obtained in these experiments using a quick-stop device and examined in a scanning electron microscope. Clear evidence of material separation is seen at the interface zone between the chip and machined surface even when the edge radius is large compared to the uncut chip thickness. Failure is seen to occur at the upper, middle, and/or the lower edges of the interface zone. Based on these observations, a hypothesis is presented for the events leading to the occurrence of this failure when cutting with an edge radius tool. Finite element simulations are performed to study the nature of stress state ahead of the tool edge with and without edge radius. Hydrostatic stress is seen to be tensile in front of the tool and hence favors the occurrence of ductile fracture leading to material separation. The stress components are, however lower than those seen with a sharp tool

  16. It is not just comfort: waterproof casting increases physical functioning in children with minimally angulated distal radius fractures.

    Science.gov (United States)

    Silva, Mauricio; Avoian, Tigran; Warnock, Robert Sean; Sadlik, Gal; Ebramzadeh, Edward

    2017-09-01

    Waterproof casting has been reported to increase patient comfort and satisfaction, and decrease skin irritation. There are no available data on the influence of waterproof casting materials on physical function in pediatric patients. Our aim was to determine whether the use of waterproof casting would result in faster recovery of physical function while maintaining similar clinical outcomes as those obtained with nonwaterproof materials. Twenty-six children with nonangulated or minimally angulated distal radius fractures were assigned randomly to initially receive a short-arm cast made of one of two optional materials: a hybrid mesh material with a waterproof lining or fiberglass with a nonwaterproof skin protector. Two weeks later, the initial cast was removed and replaced with a short-arm cast made of the alternative option. We compared the rate of fracture displacement, physical function, pain, skin changes, itchiness, and patient satisfaction. No evidence of displacement was found in either group. The mean Activities Scale for Kids - Performance (ASK-P) (physical function) score was 10% higher during the period of time when a waterproof cast was used (P=0.04). When a waterproof cast was used during the first 2 weeks of treatment, the mean total ASK-P scores were 23% higher than that when a nonwaterproof one was used during the same period of time (P=0.003). Patients who received a waterproof cast as the initial treatment reported lower functional scores overall and in almost every domain of the ASK-P once they were in a nonwaterproof one; similarly, those who received a nonwaterproof cast as the initial treatment reported higher functional scores overall and in every domain of the ASK-P once they were in a waterproof cast. Compared with a nonwaterproof cast, the use of waterproof casting resulted in comparable levels of pain, itchiness, skin irritability, and overall patient satisfaction. The results of this randomized, cross-over trial suggest that the use of

  17. Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery.

    Science.gov (United States)

    Magaraggia, Jessica; Wei, Wei; Weiten, Markus; Kleinszig, Gerhard; Vetter, Sven; Franke, Jochen; John, Adrian; Egli, Adrian; Barth, Karl; Angelopoulou, Elli; Hornegger, Joachim

    2017-01-01

    During a standard fracture reduction and fixation procedure of the distal radius, only fluoroscopic images are available for planning of the screw placement and monitoring of the drill bit trajectory. Our prototype intra-operative framework integrates planning and drill guidance for a simplified and improved planning transfer. Guidance information is extracted using a video camera mounted onto a surgical drill. Real-time feedback of the drill bit position is provided using an augmented view of the planning X-rays. We evaluate the accuracy of the placed screws on plastic bones and on healthy and fractured forearm specimens. We also investigate the difference in accuracy between guided screw placement versus freehand. Moreover, the accuracy of the real-time position feedback of the drill bit is evaluated. A total of 166 screws were placed. On 37 plastic bones, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text] in tip position and orientation (azimuth and elevation), respectively. On the three healthy forearm specimens, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text]. On the two fractured specimens, we attained: [Formula: see text] mm, [Formula: see text] and [Formula: see text]. When screw plans were applied freehand (without our guidance system), the achieved accuracy was [Formula: see text] mm, [Formula: see text], while when they were transferred under guidance, we obtained [Formula: see text] mm, [Formula: see text]. Our results show that our framework is expected to increase the accuracy in screw positioning and to improve robustness w.r.t. freehand placement.

  18. Identification of fracture zones and its application in automatic bone fracture reduction.

    Science.gov (United States)

    Paulano-Godino, Félix; Jiménez-Delgado, Juan J

    2017-04-01

    The preoperative planning of bone fractures using information from CT scans increases the probability of obtaining satisfactory results, since specialists are provided with additional information before surgery. The reduction of complex bone fractures requires solving a 3D puzzle in order to place each fragment into its correct position. Computer-assisted solutions may aid in this process by identifying the number of fragments and their location, by calculating the fracture zones or even by computing the correct position of each fragment. The main goal of this paper is the development of an automatic method to calculate contact zones between fragments and thus to ease the computation of bone fracture reduction. In this paper, an automatic method to calculate the contact zone between two bone fragments is presented. In a previous step, bone fragments are segmented and labelled from CT images and a point cloud is generated for each bone fragment. The calculated contact zones enable the automatic reduction of complex fractures. To that end, an automatic method to match bone fragments in complex fractures is also presented. The proposed method has been successfully applied in the calculation of the contact zone of 4 different bones from the ankle area. The calculated fracture zones enabled the reduction of all the tested cases using the presented matching algorithm. The performed tests show that the reduction of these fractures using the proposed methods leaded to a small overlapping between fragments. The presented method makes the application of puzzle-solving strategies easier, since it does not obtain the entire fracture zone but the contact area between each pair of fragments. Therefore, it is not necessary to find correspondences between fracture zones and fragments may be aligned two by two. The developed algorithms have been successfully applied in different fracture cases in the ankle area. The small overlapping error obtained in the performed tests

  19. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    Science.gov (United States)

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group

  20. Radiographic evaluation of acute distal radius fracture stability: A comparative cadaveric study between a thermo-formable bracing system and traditional fiberglass casting.

    Science.gov (United States)

    Santoni, Brandon G; Aira, Jazmine R; Diaz, Miguel A; Kyle Stoops, T; Simon, Peter

    2017-08-01

    Distal radius fractures are common musculoskeletal injuries and many can be treated non-operatively with cast immobilization. A thermo-formable brace has been developed for management of such fractures, but no data exist regarding its comparative stabilizing efficacy to fiberglass casting. A worst-case distal radius fracture was created in 6 cadaveric forearms. A radiolucent loading fixture was created to apply cantilever bending/compression loads ranging from 4.5N to 66.7N across the simulated fracture in the: (1) non-stabilized, (2) braced; and (3) casted forearms, each forearm serving as its own control. Fracture fragment translations and rotations were measured radiographically using orthogonal radiographs and a 2D-3D, CT-based transformation methodology. Under 4.5N of load in the non-stabilized condition, average sagittal plane rotation and 3D center of mass translation of the fracture fragment were 12.3° and 5.3mm, respectively. At the 4.5N load step, fragment rotation with the brace (avg. 0.0°) and cast (0.1°) reduced sagittal plane rotation compared to the non-stabilized forearm (Pthermo-formable brace stabilized the fracture in a manner that was not radiographically or biomechanically different from traditional fiberglass casting. Study results support the use of the thermo-formable brace clinically. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Feasibility of a reduction protocol in the emergency department for diaphyseal forearm fractures in children.

    Science.gov (United States)

    Pesenti, S; Litzelmann, E; Kahil, M; Mallet, C; Jehanno, P; Mercier, J-C; Ilharreborde, B; Mazda, K

    2015-09-01

    Diaphyseal forearm fractures are very common pediatric traumas. At present, distal radius metaphyseal fractures are often successfully treated with closed reduction by emergency physicians. However, the management of diaphyseal fractures remains controversial. The purpose of this study was to analyze the results of diaphyseal forearm fractures in the emergency department (ED) in children. In a prospective 2-year-study, all closed diaphyseal forearm fractures in patients under 15, with an angle of >15° and treated by closed reduction in the ED were included. Fractures with overlapping fragments were excluded. Reduction was performed by an emergency physician, with a standardized analgesic protocol (painkillers and nitrous oxide). Clinical tolerance was checked within the first 24hours, and the radiographic stability of reduction was assessed at days 8 and 15. Initial and final follow-up radiographs were analyzed. Elbow and wrist range of motion was assessed at the final follow-up. Sixty patients (41 boys and 19 girls) were included. Mean age was 5.2 years old (±3). At initial evaluation, the maximum angle was 30° (±11.3). After reduction, the maximum angle was significantly reduced (30° vs. 5°, P<0.001). Mean immobilization in a cast was 11.7 weeks (±2). There were no cast related complications in any of these children. There was no surgery for secondary displacement. Full range of motion was obtained in all patients at the final follow-up. The outcome of conservative treatment of closed diaphyseal forearm fractures, without overlapping fragments was excellent. However, reduction is usually performed in the operating room by orthopedic surgeons under general anesthesia and requires hospitalization, which is very expensive. The results of this study show that high quality care may be obtained in the ED by a trained and experienced team. These results are similar to those for distal metaphyseal fractures, which could extend the indications for reduction in the

  2. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    Science.gov (United States)

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  3. Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Christersson, Albert; Larsson, Sune [Uppsala University, Department of Orthopaedics, Uppsala (Sweden); Nysjoe, Johan; Malmberg, Filip; Sintorn, Ida-Maria; Nystroem, Ingela [Uppsala University, Centre for Image Analysis, Uppsala (Sweden); Berglund, Lars [Uppsala University, Uppsala Clinical Research Centre, UCR Statistics, Uppsala (Sweden)

    2016-06-15

    The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4 , ± 1.9 and ± 6.8 respectively. For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested. (orig.)

  4. Reabilitação das fraturas do rádio distal Rehabilitation of distal radius fractures

    Directory of Open Access Journals (Sweden)

    Patrícia Silva Hampe Barbosa

    2009-01-01

    Full Text Available O objetivo deste estudo foi avaliar a evidência do efeito e eleição da conduta terapêutica nas fraturas do rádio distal. A revisão sistemática utilizou as bases de dados PubMed, Lilacs, Pedro, Cochrane, Scielo, OTseeker, sem restrições de período de publicação, com as seguintes palavras chaves: fraturas do rádio, reabilitação, terapia ocupacional, fisioterapia, incluindo línguas inglesa, espanhola, francesa e portuguesa. Os estudos encontrados foram avaliados independentemente pelos dois autores utilizando critérios da escala PEDro. Estudos não experimentais foram incluídos em busca de esclarecimentos sobre a reabilitação. Foram encontrados 22 estudos, sendo 14 ensaios clínicos controlados randomizados (ECRs. Dentre eles, quatro compararam mobilização precoce com tratamento convencional apresentando evidência moderada a favor da primeira; sete confrontaram tratamento baseado em exercícios domiciliares com tratamento em consultório apontando evidência conflitiva (um deles também comprovou eficácia de mobilização acessória passiva; e três analisaram eficácia de procedimentos terapêuticos: campo eletromagnético pulsado, drenagem linfática, ultra-som, indicando evidências limitadas. Os nove estudos não experimentais encontrados não apresentaram informações suficientes sobre os questionamentos desta pesquisa. Observou-se uma tendência dos autores em utilizar os princípios gerais da reabilitação ao elaborar condutas terapêuticas, mas os procedimentos utilizados não estão bem atestados pela literatura.The aim of this study was to assess the evidence regarding the adoption and effectiveness of therapeutic procedures employed for rehabilitation of distal radius fractures. This systematic review used the following databases: PubMed, Lilacs, PEDro, Cochrane, Scielo and OTseeker, without time restrictions. The following keywords were searched for: distal radius fracture, rehabilitation, occupational therapy

  5. External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients

    Science.gov (United States)

    Ma, Chuang; Deng, Qiang; Pu, Hongwei; Cheng, Xinchun; Kan, Yuhua; Yang, Jing; Yusufu, Aihemaitijiang; Cao, Li

    2016-01-01

    The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after 1 week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P=0.001), supination, (P=0.047) and extension (P=0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at 1 year. The plating group had a greater occurrence of wound infection (P=0.043), tendonitis, (P=0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the “gross motor” category (walking upstairs, bending over, walking 500 yards; P=0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after 1 year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries. PMID:27408765

  6. Open versus closed reduction: diacapitular fractures of the mandibular condyle.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2012-09-01

    The purpose of the study was to review the literature regarding the evolution of current thoughts on management of diacapitular fractures (DFs) of the mandibular condyle. An electronic search in PubMed was undertaken in March 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies reporting clinical series of DFs, including both animal and human studies, without date or language restrictions. The search strategy initially yielded 108 references. Twenty-eight studies were identified without repetition within the selection criteria. Additional hand-searching of the reference lists of selected studies yielded three additional papers. The current indications for open reduction and internal fixation (ORIF) of DFs described in the literature are: (a) fractures affecting the lateral condyle with reduction of mandibular height; (b) fractures in which the proximal fragment dislocates laterally out of the glenoid fossa, which cannot be reduced by closed or open treatment of another part of the mandibular fracture. The indications for conservative treatment are: (a) fractures that do not shorten the condylar height (a fracture with displacement of the medial parts of the condyle); (b) undisplaced fractures; (c) comminution of the condylar head, when the bony fragments are too small for stable fixation; and (d) fractures in children. As the temporomandibular joint disk plays an important role as a barrier preventing ankylosis, it is important to reposition the disk (if displaced/dislocated) during the surgical treatment of DFs. The lateral pterygoid muscle should never be stripped from the medially displaced fragment because its desinsertion disrupts circulation to the medial bony fragment, and also because this muscle helps to restore the muscle function after surgery. ORIF of selected DFs improves prognosis by anatomical bone and soft tissue recovery when combined with physical

  7. Elbow dislocation with ipsilateral fracture of the distal radius associated with a brachial artery injury: A new pathological condition of traumatic origin.

    Science.gov (United States)

    Trigo Lahoz, L; Lamas Gomez, C; Sarasquete Reiriz, J; de Caso Rodriguez, J; Proubasta Renart, I

    Elbow dislocation associated with ipsilateral fracture of the distal radius and a brachial artery injury is an uncommon traumatic entity. The two references of this injury combination appeared in 2015, although both authors did not realise that they were the first two cases published in the medical literature. Although mentioned in the text of the articles, no mention was made of the fracture of the distal radius in the titles. The purpose of this paper is to present three cases with this new traumatic pathological entity, explaining its pathogenetic mechanism, the treatment used, and the results obtained. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Science.gov (United States)

    Yang, Jung-Dug; Chung, Ho-Yun; Cho, Byung-Chae

    2012-01-01

    In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and deviation of the mandible. In the past, closed reduction with concomitant active physical therapy conducted after intermaxillary fixation during the recovery period had been mainly used, but in recent years, open treatment of condylar fractures with rigid internal fixation has become more common. The objective of this review was to evaluate the main variables that determine the choice of an open or closed method for treatment of condylar fractures, identifying their indications, advantages, and disadvantages, and to appraise the current evidence regarding the effectiveness of interventions that are used in the management of fractures of the mandibular condyle. PMID:22872831

  9. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available In the treatment of mandibular condyle fracture, conservative treatment using closed reduction or surgical treatment using open reduction can be used. Management of mandibular condylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma. For each type of condylar fracture,the treatment method must be chosen taking into consideration the presence of teeth, fracture height, patient'sadaptation, patient's masticatory system, disturbance of occlusal function, and deviation of the mandible. In the past, closed reduction with concomitant active physical therapy conducted after intermaxillary fixation during the recovery period had been mainly used, but in recent years, open treatment of condylar fractures with rigid internal fixation has become more common. The objective of this review was to evaluate the main variables that determine the choice of an open or closed method for treatment of condylar fractures, identifying their indications, advantages, and disadvantages, and to appraise the current evidence regarding the effectiveness of interventions that are used in the management of fractures of the mandibular condyle.

  10. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    Science.gov (United States)

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted

  11. [Frequency of diagnosis of postmenopausal osteoporosis of the spine, distant radius and extravertebral fractures in women with normal body mass, overweight and obesity].

    Science.gov (United States)

    Popov, A A; Izmozherova, N V; Fominykh, M I; Tagil'tseva, N V; Kozulina, E V; Gavrilova, E I

    2008-01-01

    To assess features and peculiarities of postmenopausal osteoporosis (OP) in women with normal body mass, overweight and obesity. Dual energy X-ray absorptiometry of the lumbal spine (Lunar DPX) and distal radius X-ray absorptiometry (DTX 200) were performed during cross-section study of 730 symptomatic postmenopausal women. OP was diagnosed in 253 (34.7%) women, 30.5% of them had normal body mass, 43.2% had overweight and 26.3% were obese. Among them 227 had atraumatic fractures at the age over 50 years. Obese OP patients had significantly higher frequency of arterial hypertension, chronic heart failure, osteoarthritis and glucose metabolism disorders than osteoporotic patients with normal body mass. Fracture frequency did not differ between groups with normal body mass, overweight and obesity. Excessive body mass did not decrease fracture risk in women with postmenopausal OP.

  12. A prospective study on the effectiveness of cotton versus waterproof cast padding in maintaining the reduction of pediatric distal forearm fractures.

    Science.gov (United States)

    Robert, Christopher E; Jiang, Jimmy J; Khoury, Joseph G

    2011-03-01

    Distal forearm fractures, one of the most common fractures seen in the pediatric population, are regularly treated by closed reduction and casting. Our study investigates the effectiveness of Gore-Tex-lined casting in maintaining the reduction of 100% displaced distal forearm fractures compared with traditional cotton-lined casts. We screened all patients from February 2007 to July 2009 who presented to Children's Hospital in Birmingham, AL with a distal radius fracture. Only patients with 100% displaced distal radius fractures were eligible to be assigned to either the cotton-lined or Gore-Tex-lined cast groups. Power analysis was performed to identify an adequate patient sample size. The mean maximum change between initial post-reduction x-rays and follow-up x-rays for anterior-posterior (AP) angulation, AP displacement, lateral angulation, and lateral displacement of the radius were calculated for both cotton and Gore-Tex groups. The rate of subsequent intervention and/or unacceptable results for each group was also analyzed. Seven hundred and twenty-two patients were treated with distal radius fractures at our hospital with 59 patients eligible for inclusion in our study. Thirty-six of our patients were treated with cotton-lined casts, and 23 patients were treated with Gore-Tex-lined cast. The mean maximum change in AP angulation, AP displacement, lateral angulation, and lateral displacement of the radius after initial reduction was 9.2 degrees, 6.9%, 13.9 degrees, and 13.6%, respectively, for the cotton-lined cast group and 7.7 degrees, 6.1%, 14.6 degrees, and 9.6%, respectively, for the Gore-Tex-lined cast group. There were no statistical differences between the means of the 4 measurements (P=0.33, 0.69, 0.73, and 0.10, respectively). There were also no significant differences between groups for final AP and lateral angulation and displacement. Subgroup analysis showed no significant differences in all measurements between cotton and Gore-Tex groups. Gore

  13. Multiscale model reduction for shale gas transport in fractured media

    KAUST Repository

    Akkutlu, I. Y.

    2016-05-18

    In this paper, we develop a multiscale model reduction technique that describes shale gas transport in fractured media. Due to the pore-scale heterogeneities and processes, we use upscaled models to describe the matrix. We follow our previous work (Akkutlu et al. Transp. Porous Media 107(1), 235–260, 2015), where we derived an upscaled model in the form of generalized nonlinear diffusion model to describe the effects of kerogen. To model the interaction between the matrix and the fractures, we use Generalized Multiscale Finite Element Method (Efendiev et al. J. Comput. Phys. 251, 116–135, 2013, 2015). In this approach, the matrix and the fracture interaction is modeled via local multiscale basis functions. In Efendiev et al. (2015), we developed the GMsFEM and applied for linear flows with horizontal or vertical fracture orientations aligned with a Cartesian fine grid. The approach in Efendiev et al. (2015) does not allow handling arbitrary fracture distributions. In this paper, we (1) consider arbitrary fracture distributions on an unstructured grid; (2) develop GMsFEM for nonlinear flows; and (3) develop online basis function strategies to adaptively improve the convergence. The number of multiscale basis functions in each coarse region represents the degrees of freedom needed to achieve a certain error threshold. Our approach is adaptive in a sense that the multiscale basis functions can be added in the regions of interest. Numerical results for two-dimensional problem are presented to demonstrate the efficiency of proposed approach. © 2016 Springer International Publishing Switzerland

  14. Current Concepts in the Mandibular Condyle Fracture Management Part II: Open Reduction Versus Closed Reduction

    Directory of Open Access Journals (Sweden)

    Kang-Young Choi

    2012-07-01

    Full Text Available In the treatment of mandibular condyle fracture, conservative treatment using closedreduction or surgical treatment using open reduction can be used. Management of mandibularcondylar fractures remains a source of ongoing controversy in oral and maxillofacial trauma.For each type of condylar fracture,the treatment method must be chosen taking intoconsideration the presence of teeth, fracture height, patient’sadaptation, patient’s masticatorysystem, disturbance of occlusal function, and deviation of the mandible. In the past, closedreduction with concomitant active physical therapy conducted after intermaxillary fixationduring the recovery period had been mainly used, but in recent years, open treatment ofcondylar fractures with rigid internal fixation has become more common. The objectiveof this review was to evaluate the main variables that determine the choice of an open orclosed method for treatment of condylar fractures, identifying their indications, advantages,and disadvantages, and to appraise the current evidence regarding the effectiveness ofinterventions that are used in the management of fractures of the mandibular condyle.

  15. [Case-control study on tibetan Baimai ointment (see symbol in text) for the treatment of wrist-dysfunction after distal radius fracture].

    Science.gov (United States)

    Zhang, Xing-ping; Xu, Gen-rong; Xu, Shan-qiang; Lu, Ze-ming; Huang, Lei

    2014-11-01

    To evaluate efficacy and safety of Baimai ointment (see symbol in text) in the treatment of wrist-dysfunction after distal radius fracture. From April, 2011 to June, 2012, 43 patients with distal radius fracture were treated with plaster fixation. All the patients were divided into two group: test group and control group. Twenty-one patients in test group and 22 in control group, and the baseline was balance (P > 0.05). The 21 patients in test group were treated with Baimai ointment (see symbol in text), fomentation, functional exercises. The 22 patients in control group were treated with placebo, fomentation, functional exercises. Foment affected side wrist with wet towel in 20 min before medication, with the temperature between 50 degrees C and 60 degrees C. Smear drugs uniformly in range of 3 cm in the vicinity of palm stripes after drying (about 3 g) and take functional exercises for the activities of wrist and hand. Continuous follow the program per 8 hours once and follow-up for 8 weeks. The Wrist's pain was assessed with VAS. The wrist's activities were measured with the protractor of orthopedic. Measure The grip strength was measured with dynamometer. The wrist's function were assessed with the table of Cooney. The test group had a significantly better results than those of control group in the extent of wrist's pain throughout the treatment (P 0.05). There were no drug adverse reactions occurred. Tibetan Baimai ointment (see symbol in text) has the treatment of wrist-dysfunction after distal radius fracture for external use, which can reduce the extent of wrist's pain, promote grip strength recovery in the middle and late of process, promote wrist's function recovery latterly, and safety for external use.

  16. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  17. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  18. Recommendation for measuring clinical outcome in distal radius fractures: a core set of domains for standardized reporting in clinical practice and research.

    Science.gov (United States)

    Goldhahn, Jörg; Beaton, Dorcas; Ladd, Amy; Macdermid, Joy; Hoang-Kim, Amy

    2014-02-01

    Lack of standardization of outcome measurement has hampered an evidence-based approach to clinical practice and research. We adopted a process of reviewing evidence on current use of measures and appropriate theoretical frameworks for health and disability to inform a consensus process that was focused on deriving the minimal set of core domains in distal radius fracture. We agreed on the following seven core recommendations: (1) pain and function were regarded as the primary domains, (2) very brief measures were needed for routine administration in clinical practice, (3) these brief measures could be augmented by additional measures that provide more detail or address additional domains for clinical research, (4) measurement of pain should include measures of both intensity and frequency as core attributes, (5) a numeric pain scale, e.g. visual analogue scale or visual numeric scale or the pain subscale of the patient-reported wrist evaluation (PRWE) questionnaires were identified as reliable, valid and feasible measures to measure these concepts, (6) for function, either the Quick Disability of the arm, shoulder and hand questionnaire or PRWE-function subscale was identified as reliable, valid and feasible measures, and (7) a measure of participation and treatment complications should be considered core outcomes for both clinical practice and research. We used a sound methodological approach to form a comprehensive foundation of content for outcomes in the area of distal radius fractures. We recommend the use of symptom and function as separate domains in the ICF core set in clinical research or practice for patients with wrist fracture. Further research is needed to provide more definitive measurement properties of measures across all domains.

  19. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    Science.gov (United States)

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  20. Are distal radius fractures due to fragility or to falls? A consecutive case-control study of bone mineral density, tendency to fall, risk factors for osteoporosis, and health-related quality of life.

    Science.gov (United States)

    Nordvall, Helena; Glanberg-Persson, Gunhild; Lysholm, Jack

    2007-04-01

    A fracture of the distal radius is considered to indicate an increased risk of future fractures, especially a hip fracture. The main causes may be osteoporosis or a tendency to fall, separately or in combination. 93 women and 5 men with a recent radius fracture and the same number of controls were measured with a heel-DXL and asked to complete one questionnaire on their quality of life (SF-36), and one on risk factors. The mean T-score of the patients was -2.1, and for the controls it was -1.9 (p = 0.3). The patients aged over 64 years had a history of falling more often than the corresponding controls (p = 0.01), but there was no difference in T-score. By contrast, patients 45-64 years of age showed a non-significant, lower T-score (p = 0.09), but there was no difference concerning their history of falling. For all other risk factors, no differences were found between the patients and the controls. There were significant differences between the patients and the controls in some of the functions in the SF-36, due to the radius fracture. This study indicates that the underlying cause of a distal radius fracture may be different in patients aged 45-64 years and those who are more than 64 years old.

  1. Arthroscopy-Assisted Reduction and Fixation of a Transversal Glenoid Fracture: About a Case

    Directory of Open Access Journals (Sweden)

    David Zbili

    2017-01-01

    Full Text Available An articular glenoid fracture is an uncommon injury. Usually significantly displaced intra-articular glenoid fractures are treated with open reduction surgery. Conventional open surgery techniques involve high morbidity. Here we describe an arthroscopy-assisted reduction and fixation method of an Ideberg type III glenoid fracture. This method provides good articular reduction without extensive exposure or soft tissue dissection and without nerve and/or vascular lesion.

  2. Open versus closed reduction: mandibular condylar fractures in children.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2012-09-01

    The purpose of the study was to review the literature regarding the evolution of current thoughts on management of mandibular condylar fractures (MCFs) in children. An electronic search in PubMed was undertaken in May 2012. The titles and abstracts from these results were read to identify studies within the selection criteria. Eligibility criteria included studies published in English or German from the last 20 years (from 1992 onwards) reporting clinical series of MCFs in children and adolescents until the age of 18. The search strategy initially identified 542 studies. The references from 1992 onwards totaled 339 articles. Twenty-seven studies were identified without repetition within the selection criteria. Additional hand-searching yielded two additional papers. Pediatric MCFs require thoughtful consideration in management to avoid significant growth disturbance. Early treatment is indicated in order to improve the chances for favorable development. Long-term follow-up is required, in order to properly treat late complications that may appear. Coronal computed tomography is helpful in substantiating the correct final diagnosis. Many studies show that conservative treatment (CTR) has satisfactory long-term outcome of jaw function, occlusion, and facial esthetics, despite a high frequency of radiological aberrations. Surgery before puberty should be reserved for exceptional cases such as missile injuries, in cases with extensive dislocation and lack of contact between the fragments, in cases with multiple midfacial fractures, in which the mandible has to serve as a guide to reposition the midfacial bones, and in cases which the dislocation of the fractured stump creates a functional impediment that cannot be resolved by CTR. As the craniofacial skeleton becomes more adult-like in its form at about 12 years of age, the decreased remodeling capacity in the adolescents may occasionally result in abnormally shaped condylar heads or shortened ramus heights that may

  3. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  4. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  5. Timing of Surgical Reduction and Stabilization of Talus Fracture-Dislocations.

    Science.gov (United States)

    Buckwalter V, Joseph A; Westermann, Robert; Mooers, Brian; Karam, Matthew; Wolf, Brian

    Talus fractures with associated dislocations are rare but have high rates of complications, including avascular necrosis (AVN). Management of these injuries involves urgent surgical reduction and fixation, although there are no definitive data defining an operative time frame for preserving the blood supply and preventing complications. To determine the effect of time to surgical reduction of talus fractures and talus fracture-dislocations on rates of AVN and posttraumatic osteoarthritis (PTOA), we retrospectively reviewed talus fractures surgically managed at a level I trauma center during the 10-year period 2003 to 2013. Operative reports were obtained and reviewed, and 3 independent reviewers, using the Hawkins and AO/OTA (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association) systems, classified the injuries on plain radiographs. Analysis of AO/OTA 81 fractures with associated tibiotalar, subtalar, or talonavicular dislocations was performed. Primary outcomes were presence of AVN/PTOA and subsequent arthrodesis of tibiotalar or subtalar joints. We identified 106 surgically managed talus fractures. Rates of AVN/PTOA were 41% for all talus fractures and 50% for talus fracture-dislocations. Mean time to surgical reduction was not significant for development of AVN/PTOA for all talus fractures (P = .45) or talus fracture-dislocations (P = .29). There was no difference in age (P = .20), body mass index (P = .45), or polytrauma (P = .79) between patients who developed AVN and those who did not. Open fractures were significantly correlated with the development of AVN/PTOA (P = .009). Talar fracture-dislocations are devastating injuries with high rates of complications. Our data suggest there is no effect of time from injury to surgical reduction of talus fractures or talus fracture-dislocations on rates of AVN and PTOA.

  6. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    Science.gov (United States)

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  7. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  8. Three-dimensional assessment of unilateral subcondylar fracture using computed tomography after open reduction

    Directory of Open Access Journals (Sweden)

    Sathya Kumar Devireddy

    2014-01-01

    Full Text Available Objective: The aim was to assess the accuracy of three-dimensional anatomical reductions achieved by open method of treatment in cases of displaced unilateral mandibular subcondylar fractures using preoperative (pre op and postoperative (post op computed tomography (CT scans. Materials and Methods: In this prospective study, 10 patients with unilateral sub condylar fractures confirmed by an orthopantomogram were included. A pre op and post op CT after 1 week of surgical procedure was taken in axial, coronal and sagittal plane along with three-dimensional reconstruction. Standard anatomical parameters, which undergo changes due to fractures of the mandibular condyle were measured in pre and post op CT scans in three planes and statistically analysed for the accuracy of the reduction comparing the following variables: (a Pre op fractured and nonfractured side (b post op fractured and nonfractured side (c pre op fractured and post op fractured side. P < 0.05 was considered as significant. Results: Three-dimensional anatomical reduction was possible in 9 out of 10 cases (90%. The statistical analysis of each parameter in three variables revealed (P < 0.05 that there was a gross change in the dimensions of the parameters obtained in pre op fractured and nonfractured side. When these parameters were assessed in post op CT for the three variables there was no statistical difference between the post op fractured side and non fractured side. The same parameters were analysed for the three variables in pre op fractured and post op fractured side and found significant statistical difference suggesting a considerable change in the dimensions of the fractured side post operatively. Conclusion: The statistical and clinical results in our study emphasised that it is possible to fix the condyle in three-dimensional anatomical positions with open method of treatment and avoid post op degenerative joint changes. CT is the ideal imaging tool and should be used on

  9. Reliability and validity of selected measures associated with increased fall risk in females over the age of 45 years with distal radius fracture - A pilot study.

    Science.gov (United States)

    Mehta, Saurabh P; MacDermid, Joy C; Richardson, Julie; MacIntyre, Norma J; Grewal, Ruby

    2015-01-01

    Clinical measurement. This study examined test-retest reliability and convergent/divergent construct validity of selected tests and measures that assess balance impairment, fear of falling (FOF), impaired physical activity (PA), and lower extremity muscle strength (LEMS) in females >45 years of age after the distal radius fracture (DRF) population. Twenty one female participants with DRF were assessed on two occasions. Timed Up and Go, Functional Reach, and One Leg Standing tests assessed balance impairment. Shortened Falls Efficacy Scale, Activity-specific Balance Confidence scale, and Fall Risk Perception Questionnaire assessed FOF. International Physical Activity Questionnaire and Rapid Assessment of Physical Activity were administered to assess PA level. Chair stand test and isometric muscle strength testing for hip and knee assessed LEMS. Intraclass correlation coefficients (ICC) examined the test-retest reliability of the measures. Pearson correlation coefficients (r) examined concurrent relationships between the measures. The results demonstrated fair to excellent test-retest reliability (ICC between 0.50 and 0.96) and low to moderate concordance between the measures (low if r ≤ 0.4; moderate if r = 0.4-0.7). The results provide preliminary estimates of test-retest reliability and convergent/divergent construct validity of selected measures associated with increased risk for falling in the females >45 years of age after DRF. Further research directions to advance knowledge regarding fall risk assessment in DRF population have been identified. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  10. Injuries of the scapholunate and lunotriquetral ligaments as well as the TFCC in intra-articular distal radius fractures. Prevalence assessed with MDCT arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Klempka, A.; Wagner, M.; Fodor, S.; Schmitt, R. [Cardiovascular Center Bad Neustadt an der Saale, Department of Diagnostic and Interventional Radiology, Bad Neustadt an der Saale (Germany); Prommersberger, K.J. [Clinic for Hand Surgery, Bad Neustadt an der Saale (Germany); Uder, M. [Friedrich-Alexander-University Erlangen-Nuernberg (FAU), Department of Diagnostic Radiology, Erlangen (Germany)

    2016-03-15

    To evaluate the prevalence of injuries of the scapholunate and lunotriquetral interosseous ligaments (SLIL, LTIL) as well as the triangular fibrocartilage complex (TFCC) in intra-articular distal radius fractures (iaDRF). Two hundred and thirty-three patients with acute iaDRF underwent MDCT arthrography. The SLIL and LTIL were described as normal, partially or completely ruptured. Major injuries of the SLIL were defined as completely ruptured dorsal segments, those of the LTIL as completely ruptured palmar segments. The TFCC was judged as normal or injured. Interobserver variability was calculated. Injury findings were correlated with the types of iaDRF (AO classification). In 159 patients (68.2 %), no SLIL injuries were seen. Minor SLIL injuries were detected in 54 patients (23.2 %), major injuries in 20 patients (8.6 %). No correlation was found between the presence of SLIL lesions and the types of iaDRF. Minor LTIL injuries were seen in 23 patients (9.9 %), major injuries in only 5 patients (2.2 %). The TFCC was altered in 141 patients (60.5 %). Interobserver variability was high for MDCT arthrography in assessing SLIL and TFC lesions, and fair for LTIL lesions. In iaDRF, prevalence of major injuries of the most relevant SLIL is about 9 % as evaluated with CT arthrography. (orig.)

  11. Reduction of femoral fractures in long-term care facilities: the Bavarian fracture prevention study.

    Directory of Open Access Journals (Sweden)

    Clemens Becker

    Full Text Available BACKGROUND: Hip fractures are a major public health burden. In industrialized countries about 20% of all femoral fractures occur in care dependent persons living in nursing care and assisted living facilities. Preventive strategies for these groups are needed as the access to medical services differs from independent home dwelling older persons at risk of osteoporotic fractures. It was the objective of the study to evaluate the effect of a fall and fracture prevention program on the incidence of femoral fracture in nursing homes in Bavaria, Germany. METHODS: In a translational intervention study a fall prevention program was introduced in 256 nursing homes with 13,653 residents. The control group consisted of 893 nursing homes with 31,668 residents. The intervention consisted of staff education on fall and fracture prevention strategies, progressive strength and balance training, and on institutional advice on environmental adaptations. Incident femoral fractures served as outcome measure. RESULTS: In the years before the intervention risk of a femoral fracture did not differ between the intervention group (IG and control group (CG. During the one-year intervention period femoral fracture rates were 33.6 (IG and 41.0/1000 person years (CG, respectively. The adjusted relative risk of a femoral fracture was 0.82 (95% CI 0.72-0.93 in residents exposed to the fall and fracture prevention program compared to residents from CG. CONCLUSIONS: The state-wide dissemination of a multi-factorial fall and fracture prevention program was able to reduce femoral fractures in residents of nursing homes.

  12. Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

    Directory of Open Access Journals (Sweden)

    Yewon Lee

    2014-11-01

    Full Text Available BackgroundFrontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures.MethodsBetween March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws.ResultsContour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed.ConclusionsThe subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

  13. Multiscale model reduction for shale gas transport in fractured media

    KAUST Repository

    Akkutlu, I. Y.; Efendiev, Yalchin R.; Vasilyeva, Maria

    2016-01-01

    fracture distributions on an unstructured grid; (2) develop GMsFEM for nonlinear flows; and (3) develop online basis function strategies to adaptively improve the convergence. The number of multiscale basis functions in each coarse region represents

  14. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    Science.gov (United States)

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. A remediation performance model for enhanced metabolic reductive dechlorination of chloroethenes in fractured clay till

    DEFF Research Database (Denmark)

    Manoli, Gabriele; Chambon, Julie C.; Bjerg, Poul L.

    2012-01-01

    A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation...

  16. Reduction of lateral forces between the railway vehicle and the track in small-radius curves by means of active elements

    Directory of Open Access Journals (Sweden)

    Michálek T.

    2011-12-01

    Full Text Available This paper deals with a possibility of reduction of guiding forces magnitude in small-radius curves by means of active elements. These guiding forces characterize the lateral force interaction between the rail vehicle and the track and influence the wear of wheels and rails in curves. Their magnitudes are assessed in the framework of vehicle authorization process. However, in case of new railway vehicles with axleload of approximately 20t and more it is problematic to meet the condition of maximum value of the quasistatic guiding force which acts on the outer wheel of the 1st wheelset in small-radius curves. One of the possible ways how to reduce these forces is using the system of active yaw dampers. By means of computer simulations of guiding behaviour of a new electric locomotive, comparison of reached values of the quasistatic guiding forces in case of locomotive equipped with active yaw dampers and without them was performed. Influences of magnitude of force generated by the active yaw dampers, friction coefficient in wheel/rail contact and curve radius were analysed in this work, as well.

  17. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    Science.gov (United States)

    Shin, Sang-Jin; Sohn, Hoon-Sang; Do, Nam-Hoon

    2012-10-01

    To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. : Prospective clinical series study. University hospital. Twenty-one patients with acute displaced humeral shaft fractures were treated by MIPO with a modified fracture reduction technique. A narrow 4.5/5.0-mm locking compression plate was applied to the anterior aspect of the humerus. Fracture reduction and manipulation were performed using a plate and drill bits. The operating time, time to union, humeral alignment, and functional outcome of the shoulder and elbow joints were evaluated using the University of California Los Angeles shoulder score and Mayo elbow performance score. No patient experienced a neurological complication. Bony union was obtained in 20/21 patients at a mean 17.5 weeks postoperatively. Eighteen patients had excellent and 3 patients had good results in the University of California Los Angeles score. The average Mayo elbow performance score was 97.5. Two patients were converted to an open reduction during operation due to a failure of MIPO. There was 1 nonunion and 1 malunion in this series. Although the MIPO technique for humeral shaft fractures is technically demanding, satisfactory clinical outcomes in terms of bony union and shoulder and elbow function can be obtained using the modified fracture reduction method. Potential postoperative complications, such as malreduction and nonunion, must be considered. Appropriate surgical indications, a thorough understanding of the neurovascular anatomy and skillful surgical technique, are needed to reduce potential complications.

  18. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Early functional postoperative therapy of distal radius fracture with a dynamic orthosis: results of a prospective randomized cross-over comparative study.

    Directory of Open Access Journals (Sweden)

    Fabian M Stuby

    Full Text Available This study was conducted according to GCP criteria as a prospective randomized cross-over study. The primary goal of the study was to determine clinical findings and patient satisfaction with postoperative treatment. 29 patients with a distal radius fracture that was surgically stabilized from volar and who met the inclusion criteria were enrolled over a 12-month period. Each patient randomly received either a dorsal plaster splint or a vacuum-fit flexible but blocked orthosis applied postoperatively in the operating theatre to achieve postoperative immobilization. After one week all patients were crossed over to the complementary device maintaining the immobilization until end of week 2. After week 2 both groups were allowed to exercise wrist mobility with a physiotherapist, in the orthosis group the device was deblocked, thus allowing limited wrist mobility. After week 4 the devices were removed in both groups. Follow-up exams were performed after postoperative weeks 1, 2, 4 and 12.Results were determined after week 1 and 2 using SF 36 and a personally compiled questionnaire; after weeks 4 and 12 with a clinical check-up, calculation of ROM and the DASH Score. Comparison of the two groups showed a significant difference in ROM for volar flexion after 4 weeks, but no significant differences in DASH Score, duration of disability or x-ray findings. With regard to satisfaction with comfort and hygiene, patients were significantly more satisfied with the dynamic orthosis, and 23 of the 29 patients would prefer the flexible vacuum orthosis in future.German Clinical Trials Register (DRKS DRKS00006097.

  20. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    Science.gov (United States)

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  1. Reduction and Fixation of Unstable Fractures of the Zygomatic Arch ...

    African Journals Online (AJOL)

    Radiographs in the occipitomental and submentovertex views are most ... the bone and zygomatic arch, depending on the location of the fracture points and ... lesions in the facial nerve. ... [1,2] Thus, the diagnosis of this condition is based on ...

  2. Intraocular pressure variations during zygomatic fracture reduction and fixation: a clinical study.

    LENUS (Irish Health Repository)

    Murray, Dylan J

    2012-02-03

    BACKGROUND: The reduction of midface fractures has been associated with the rare but devastating complication of blindness. An increase in intraocular pressure is important in the mechanism of blindness in this setting. In this study, the authors assessed the intraocular pressure in patients who underwent zygomatic fracture reduction (with or without fixation). METHODS: Using applanation tonometry, 29 patients underwent intraocular pressure measurements before, during, and after fracture fixation. The contralateral pressures were measured and used as the control. RESULTS: There were 29 patients with a mean age of 35 years, and the mean time to surgery was 5 days. Preoperatively, all patients had normal intraocular pressures and normal visual acuity. All patients underwent a Gillies lift and 18 patients required open reduction and fixation of the frontozygomatic suture (n = 4) or the infraorbital margin (n = 2), and the remainder (n = 12) required fixation of both points. There was no statistically significant increase in the intraocular pressures following the reduction of uncomplicated zygomatic fractures. Statistically significant pressure reductions were noted immediately after reduction and fixation. CONCLUSIONS: The surgical reduction of uncomplicated zygomatic fractures has no adverse effect on the intraocular pressure. It is the authors\\' opinion that adjunctive measures to reduce the pressures are unnecessary.

  3. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  4. Monteggia fracture dislocation equivalents - analysis of eighteen cases treated by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Singh Ajay Pal

    2012-02-01

    fracture dislocation equivalents are rare injuries and pre-surgery recognition by radiographs and 3-D CT helps make optimal plan. The poor results usually relate to intraarticular damage, coronoid fractures and comminution of the ulna and radial head fractures. Key words: Monteggia’s fracture; Radius fracture; Ulna

  5. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.

    Science.gov (United States)

    Gary, Joshua L; Munz, John W; Burgess, Andrew R

    2014-06-01

    Eccentric reaming of cortical bone near a fracture site can introduce malalignment when an intramedullary nail is placed. The authors describe a technique of reaming metadiaphyseal and diaphyseal femur fractures in which maintaining reduction at the fracture site is not necessary to obtain an excellent alignment of long bone fractures after intramedullary nailing. They have found that central reaming proximal and distal to, but not at, the fracture site allows for excellent reduction of long bone fractures when the intramedullary nail is passed. The reamer is stopped just before the fracture site and then "pushed" across the fracture prior to resumption of reaming. The authors present "push-past" reaming as a technical trick to facilitate reduction of femoral fractures treated with intramedullary nails and a consecutive series of 18 cases in which excellent postoperative alignment was achieved. Copyright 2014, SLACK Incorporated.

  6. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Keykhosro Mardanpour

    2013-07-01

    Full Text Available BACKGROUND: This study was performed to evaluate functional and radiological results of pelvic ring fractures treatment by open reduction and internal fixation. METHOD: Thirty eight patients with unstable pelvic fractures, treated from 2002 to 2008 were retrospectively reviewed. The mean patients’ age was 37 years (range 20 to 67. Twenty six patients were men (4patients with type B and 22 patients with type C fracture and 12 women (7 patients with type B and 5 patients with type C fracture. The commonest cause was a road traffic accident (N=37, about 97%. Internal fixation was done by plaque with ilioinguinal and kocher-langenbeek approaches for anterior, posterior pelvic wall and acetabulum fracture respectively. Quality of reduction was graded according to Majeed score system. RESULTS: There were 11 type-C and 27 type-B pelvic fractures according to Tile’s classification. Thirty six patients sustained additional injuries. the commonest additional injury was lower extremity fracture. The mean follow-up was 45.6 months (range 16 to 84 months.The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients with type B pelvic fractures and functional outcome was excellent in 46%, good in 27%, fair in 27% and poor in 0% of the patients with type C pelvic fractures. There were four postoperative infections. No sexual functional problem was reported. Neurologic problem like Lateral cutaneous nerve of thigh injury recovered completely in 2 patients and partially in 2 patients. There was no significant relation between functional outcome and the site of fracture (P greater than 0.005. CONCLUSION: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization. It must be carried out as soon as the general condition of the patient permits, and even up to two weeks

  7. C-arm guided closed reduction of zygomatic arch fracture

    International Nuclear Information System (INIS)

    Eo, Yoon Ki; Lee, Dong Kun; Kim, Jeong Sam; Jang, Young Il

    1999-01-01

    The zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Alling and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients

  8. Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Dennis; Toendevold, Erik

    2015-01-01

    was evaluated on reconstructed coronal and sagittal images of the acetabulum. Results - The fracture severity and patient characteristics were similar in the 2 groups. In the 3D group, 46 of 72 patients (0.6) had a perfect result after open reduction and internal fixation, and in the control group, 17 of 42 (0...

  9. A PROSPECTIVE STUDY OF SUPRACONDYLAR FRACTURES OF THE HUMERUS IN CHILDREN TREATED BY CLOSED REDUCTION

    Directory of Open Access Journals (Sweden)

    Ch. Imobi

    2015-08-01

    Full Text Available There is no universal agreement regarding the management of displaced supracondylar fracture of the humerous in children. According to some orthopaedic surgeon almost all supracondylar humeral fractures should be treated operatively by reduction and pinning. While according to others closed reduction and pinning should be used for Gartland type II and some type III fractures. We present 50 cases of displaced supracondylar fracture treated by closed manipulative reduction under G.A. and immobilization with a posterior plaster of paris slab and collar and cuff. OBJECTIVE : T o assess the functional results of the injured elbow and to study the incidence of change in the carrying angle of the elbow. MATERIALS AND METHODS: This prospective study was conducted in 50 patients with extension type of displaced supracondylar fractures of humerus in children (Gartland type II and type III treated by closed manipulative reduction and immobilization in flexion of the elbow with a posterior plaster of paris slab and collar and cuff. Patients were followed up for 6 months. Flexion type of supracondylar fracture and those fractures which are absolutely indicated for operative intervention, Viz an open fracture and severe vascular compromise were excluded from the study. The range of movement and carrying angle was measured with the help of a Goniometer and Flynn criteria were used for functional assessment. RESULTS: At the end of follow up period, the end results were graded as excellent in 40%, good in 42%, fair in 12% and poor in 6%. A satisfactory result was therefore obtained in 94% and unsatisfactory result in 6% of the 50 patients who were followed and evaluated. CONCLUSION: This closed method of treatment for all practical proposes produces least complications, shorter hospital stay, can be expected to yield reproducible consistent satisfactory results not surpassed by any other method of treatment.

  10. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  11. Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures.

    Science.gov (United States)

    Siebenrock, K A; Müller, U; Ganz, R

    1998-01-01

    Subtrochanteric fractures frequently occur as high energy trauma usually in younger patients and may lead to severe comminution of the medial cortex. The medial cortex of the proximal femur is exposed to high compressive forces which make fracture stabilization a difficult problem. Bone healing may be seriously compromised due to extensive comminution and fragment devitalization. This requires reduction techniques which do not cause additional damage to the vitality of the bone. With indirect reduction techniques and the use of a condylar blade plate the results have been significantly improved in these fracture types in our department (1). In this report the essential aspects of indirect reduction for subtrochanteric fractures using a condylar blade plate and the treatment results from our department from earlier years (1) and from the last 2 1/2 years will be presented. In the latter period, fifteen patients with a mean age of 49 years (19-87 years) were treated with this method. Fractures resulted from traffic incidents or falls from a great height in 11 cases (73%). Union was achieved in 14 cases (93%) with full weight-bearing after a mean of 3 months (1-4 1/2 months). Malunion was seen in two cases (13%) without the need for further surgery. Non union occurred in one patient (7%) with a III B open injury due to early infection. After repeated debridements, bone grafting and decortication, the fracture was stabilized with a replacement condylar blade plate and healed uneventfully.

  12. Closed reduction, internal fixation with quadratus femoris muscle pedicle bone grafting in displaced femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Chaudhuri Sibaji

    2008-01-01

    Full Text Available Background: Management of femoral neck fracture is still considered as an unsolved problem. It is more evident in displaced fractures where this fracture is considered as some sort of vascular insult to the head of the femur. We have used closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting in fresh displaced femoral neck fractures. Materials and Methods: From April 1996 to December 2004 we operated 73 consecutive patients of displaced femoral neck fracture in the age group of 24 to 81 years, mean age being 54.6 years. The patients were operated within one week of injury, the mean delay being 3.6 days. Closed reduction internal fixation along with quadratus femoris muscle pedicle bone grafting was done in all cases. They were followed up for an average period of 5.6 years (range 2-11 years. Results: Results were assessed according to modified Harris Hip Scoring system and found to be excellent in 53, good in 12, fair in six and poor in two patients. Bony union occurred in 68 cases, no patient developed avascular necrosis (AVN till date. Conclusion: For fresh displaced femoral neck fracture in physiologically active patients closed reduction, internal fixation and quadratus femoris muscle pedicle bone grafting is a suitable option to secure union and prevent development of AVN.

  13. Limited open reduction is better for simple- distal tibial shaft fractures than minimally invasive plate osteosynthesis.

    Science.gov (United States)

    Li, Q; Zeng, B F; Luo, C F; Song, S; Zhang, C Q; Kong, W Q

    2014-07-24

    The aim of this study was to compare the effects and indications of minimally invasive plate osteosynthesis (MIPO) and limited open reduction (LOR) for managing distal tibial shaft fractures. A total of 79 cases of distal tibial shaft fractures were treated surgically in our trauma center. The 79 fracture cases were classified into type A, B, and C (C1) according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification, with 28, 32, and 19 cases, respectively. Among the 79 fracture cases, 52 were closed fractures and 27 were open fractures (GUSTILO, I-II). After adequate preparation, 48 cases were treated with LOR and 31 cases were treated with MIPO. All cases were followed up for 12 to 18 months, with an average of 16.4 months. During the follow-up period, 76 fracture cases were healed in the first stage, whereas the 3 cases that developed non-union were treated by changing the fixation device and autografting. For types A, B, and some of C simple fractures (C1), LOR accelerated the fracture healing and lowered the non-union rate. One case suffered from regional soft tissue infection, which was controlled by wound dressing and intravenous antibiotics. Another case that developed local skin necrosis underwent local flap transplant. LOR promoted bone healing and lowered the non-union rate of several simple-distal tibial shaft fractures. Thereafter, the incidence of soft tissue complication was not significantly increased. However, for complex and comminuted fractures, MIPO was the preferred method for correcting bone alignment and protecting soft tissue, leading to functional recovery.

  14. Close reduction and per cutaneous pinning of supracondylar fractures of humerus in children

    International Nuclear Information System (INIS)

    Iqbal, S.; Maqbool, N.

    2014-01-01

    The purpose of this study was to assess outcome and complications associated with closed reduction and internal fixation of supracondylar fractures type III of humerus in children. Study Design: Quasi - experimental. Place and Duration of Study: Department of Orthopedics, Fauji Foundation Hospital Rawalpindi and Railway General Hospital (RGH), Rawalpindi, from June 2011 to August 2012. Material and Method: The study group included 16 boys and 8 girls aged 4-12 years with supracondyle Type III fractures of humerus, having no neurovascular injury and no appreciable edema. Relevant history and clinical details were taken. All those cases having any neurovascular injury or moderate to severe edema at elbow and presenting late more than two weeks were excluded. These cases were treated with closed reduction and internal fixation. Follow up was done for 6 months to assess the level of cosmetic and function according to the system described by Flynn's et al as excellent, good, fair and poor. Results: Study was completed on 24 patients (16 males and 8 females). All fractures were united in acceptable alignment. At final assessment there were 16 excellent, 5 good, 3 fair. No one was poor. The fair clinical outcome was higher in children above 10 years of age. Conclusion: Closed reduction and internal fixation with cast stabilization can provide precise and good fracture reduction, maintains stabilization for fracture healing, results in good cosmetic outcome, cost effective and facilitates easy removal of implants after treatment. (author)

  15. Management of complications of open reduction and internal fixation of ankle fractures.

    Science.gov (United States)

    Ng, Alan; Barnes, Esther S

    2009-01-01

    The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.

  16. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw.

    Science.gov (United States)

    Baek, Ji Eun; Chung, Chan Min; Hong, In Pyo

    2012-09-01

    Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

  17. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    Science.gov (United States)

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  18. Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs.

    Science.gov (United States)

    Cummings, Steven R; Karpf, David B; Harris, Fran; Genant, Harry K; Ensrud, Kristine; LaCroix, Andrea Z; Black, Dennis M

    2002-03-01

    To estimate how much the improvement in bone mass accounts for the reduction in risk of vertebral fracture that has been observed in randomized trials of antiresorptive treatments for osteoporosis. After a systematic search, we conducted a meta-analysis of 12 trials to describe the relation between improvement in spine bone mineral density and reduction in risk of vertebral fracture in postmenopausal women. We also used logistic models to estimate the proportion of the reduction in risk of vertebral fracture observed with alendronate in the Fracture Intervention Trial that was due to improvement in bone mineral density. Across the 12 trials, a 1% improvement in spine bone mineral density was associated with a 0.03 decrease (95% confidence interval [CI]: 0.02 to 0.05) in the relative risk (RR) of vertebral fracture. The reductions in risk were greater than predicted from improvement in bone mineral density; for example, the model estimated that treatments predicted to reduce fracture risk by 20% (RR = 0.80), based on improvement in bone mineral density, actually reduce the risk of fracture by about 45% (RR = 0.55). In the Fracture Intervention Trial, improvement in spine bone mineral density explained 16% (95% CI: 11% to 27%) of the reduction in the risk of vertebral fracture with alendronate. Improvement in spine bone mineral density during treatment with antiresorptive drugs accounts for a predictable but small part of the observed reduction in the risk of vertebral fracture.

  19. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    Science.gov (United States)

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures.

    Science.gov (United States)

    Tang, Xin; Liu, Lei; Tu, Chong-qi; Li, Jian; Li, Qi; Pei, Fu-xing

    2014-07-01

    The timing of surgery for osteosynthesis of type C pilon (AO/OTA) fractures remains controversial. The aim of this study was to determine the outcome of early and delayed open reduction and internal fixation (ORIF) for treating closed type C pilon fractures. Forty-six patients with closed type C pilon fractures matched according to age, gender, soft tissue conditions, and fracture pattern were divided into group A (early group: underwent surgery within 36 hours of the injury) or group B (delayed group: underwent surgery 10 days to 3 weeks postinjury after the soft tissue swelling subsided). In the delayed group, 9 patients were treated first by temporary external fixation. All the closed fractures were managed by ORIF with locking plates. At follow-up, the clinical and radiographic results were retrospectively analyzed. The mean follow-up time was 25.8 months (range, 14 to 48 months) in group A and 26.0 months (range, 15 to 44 months) in group B. There was no significant difference (P > .05) between the 2 groups regarding the rate of soft tissue complication, the rate of fracture union, and the final functional score. The patients in group A had a significantly shorter mean time to fracture union (21.5 ± 4.0 weeks vs 23.3 ± 3.7 weeks, P fractures can be safe and effective, with similar rates of wound complication, fracture union, and final good functional recovery but shorter operative time, union time, and hospital stay. These results favorably compare with delayed ORIF treatment. Level III, retrospective comparative study. © The Author(s) 2014.

  1. Closed treatment of overriding distal radial fractures without reduction in children.

    Science.gov (United States)

    Crawford, Scott N; Lee, Lorrin S K; Izuka, Byron H

    2012-02-01

    Traditionally, distal radial fractures with marked displacement and angulation have been treated with closed or open reduction techniques. Reduction maneuvers generally require analgesia and sedation, which increase hospital time, cost, patient risk, and the surgeon's time. In our study, a treatment protocol for pediatric distal radial fractures was used in which the fracture was left shortened in an overriding position and a cast was applied without an attempt at anatomic fracture reduction. Consecutive patients three to ten years of age presenting between 2004 and 2009 with a closed overriding fracture of the distal radial metaphysis were followed prospectively. Our protocol consisted of no analgesia, no sedation, and a short arm fiberglass cast gently molded to correct only angulation. Patients were followed for at least one year. All parents or guardians were given a questionnaire assessing their satisfaction with the treatment. Financial analysis was performed with use of Current Procedural Terminology codes and the average total cost of care. Fifty-one children with an average age of 6.9 years were included in the study. Initial radial shortening averaged 5.0 mm. Initial sagittal and coronal angulation averaged 4.0° and 3.2°, respectively. The average duration of casting was forty-two days. Residual sagittal and coronal angulation at the time of final follow-up averaged 2.2° and 0.8°, respectively. All fifty-one patients achieved clinical and radiographic union with a full range of wrist motion. All parents and guardians answered the questionnaire and were satisfied with the treatment. Cost analysis demonstrated that closed reduction with the patient under conscious sedation or general anesthesia is nearly five to six times more expensive than the treatment used in this study. Adding percutaneous pin fixation increases costs nearly ninefold. This treatment protocol presents an alternative approach to overriding distal radial fractures in children and

  2. Open reduction versus endoscopically controlled reconstruction of orbital floor fractures: a retrospective analysis.

    NARCIS (Netherlands)

    Hundepool, A.C.; Willemsen, M.A.A.P.; Koudstaal, M.J.; Wal, K.G.H. van der

    2012-01-01

    The aim of this study was to compare the postoperative results of open reduction versus endoscopically controlled reconstructions of orbital floor fractures. The medical records of 83 patients, treated between January 2000 and December 2008, were reviewed for enophthalmos, diplopia and

  3. The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

    Directory of Open Access Journals (Sweden)

    Kaykhosro Mardanpour

    2011-07-01

    Full Text Available Background:Unstable Pelvic fracture,a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This study was performed to evaluate the functional and radiological results of treatment of pelvic ring fractures by open reduction, internal fixation. Methods: Thirty eight patients with unstable pelvic fractures, treated from 2002 to2008 were retrospectively reviewed. The mean age of patients’ was 37 years old (range 20 to 67. Twenty six patients were men and 12 women. The most common cause was a road traffic accident (N=37, 97%. There were 11 type-C and 27 type-B fractures according to Tile’s classification. Thirty six patients sustained additional injuries. The most prevalent additional injuries were lower extremity fractures. Open reduction, internal fixation as a definite management was applied for all patients. Quality of reduction was graded according to the grades proposed by Matta and Majeed’s score was used to assess the clinical outcome. The mean period of follow-up was 25 months (ranged from 6 to 109 months. About 81.6% of patients had either good or excellent radiological reduction. Results: The functional outcome was excellent in 66%, good in 15%, fair in 11% and poor in 7% of the patients. There were 4 postoperative infections. No sexual function problem was reported. Nerve deficits recovered completely in 2 and partially in 3 of 11 patients with preoperative neurologic deficiency. There was no significant relation between functional outcome and the site of fracture Conclusion: Unstable pelvic ring fracture injuries should be managed surgically by rigid stabilization that must be carried out as soon as the general ndition of the patient permits, and

  4. [POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY].

    Science.gov (United States)

    Qu, Feng; Yuan, Bangtuo; Qi, Wei; Wang, Junliang; Shen, Xuezhen; Wang, Jiangtao; Zhao, Gang; Liu, Yujie

    2014-07-01

    To discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. Between January 2009 and January 2012, 9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment. Of 9 cases, 6 were men, and 3 were women, aged 21-54 years (mean, 39 years). The causes were traffic accident injury in 7 cases, falling injury from height in 1 case, and hurt injury in 1 case. The shoulder abduction, flexion, and external rotation were obviously limited. X-ray films showed all cases had obvious displaced scapular neck fracture. Three-dimensional reconstruction of CT showed a grossly displaced of fracture. The time of injury to surgery was 4-27 days (mean, 11 days). Patients obtained healing of incision by first intension, without infection, neurovascular injury, or other surgery-related complications. All patients were followed up 19- 31 months (mean, 23 months). X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean, 8 weeks). At last follow-up, the shoulder abduction, flexion, and external rotation activity were improved significantly when compared with ones at preoperation (P shoulder Constant score, American Shoulder and Elbow Surgenos (ASES) score, and Rowe score were significantly better than preoperative scores (P shoulder stability and reduce complications.

  5. Impact of Open Reduction on Surgical Strategies for Missed Monteggia Fracture in Children.

    Science.gov (United States)

    Park, Hoon; Park, Kwang Won; Park, Kun Bo; Kim, Hyun Woo; Eom, Nam Kyu; Lee, Dong Hoon

    2017-07-01

    The aims of this study were to review our cases of missed Monteggia fracture treated by open reduction of the radial head with or without ulnar osteotomy and to investigate the indications for open reduction alone in surgical treatment of missed Monteggia fracture. We retrospectively reviewed 22 patients who presented with missed Monteggia fracture. The patients' mean age at the time of surgery was 7.6 years. The mean interval from injury to surgery was 16.1 months. The surgical procedure consisted of open reduction of the radiocapitellar joint followed by ulnar osteotomy without reconstruction of the annular ligament. The mean period of follow-up was 3.8 years. Radiographic assessment was performed for the maximum ulnar bow (MUB) and the location of the MUB. Clinical results were evaluated with the Mayo Elbow Performance Index and Kim's scores. Five patients underwent open reduction alone, and 17 patients underwent open reduction and ulnar osteotomy. When the MUB was less than 4 mm and the location of the MUB was in the distal 40% of the ulna, we could achieve reduction of the radial head without ulnar osteotomy. The radial head was maintained in a completely reduced position in 21 patients and was dislocated in one patient at final follow-up. Open reduction alone can be an attractive surgical option in select patients with missed Monteggia fracture with minimal bowing of the distal ulna. However, ulnar osteotomy should be considered in patients with a definite ulnar deformity. © Copyright: Yonsei University College of Medicine 2017

  6. A partitioned model order reduction approach to rationalise computational expenses in nonlinear fracture mechanics

    Science.gov (United States)

    Kerfriden, P.; Goury, O.; Rabczuk, T.; Bordas, S.P.A.

    2013-01-01

    We propose in this paper a reduced order modelling technique based on domain partitioning for parametric problems of fracture. We show that coupling domain decomposition and projection-based model order reduction permits to focus the numerical effort where it is most needed: around the zones where damage propagates. No a priori knowledge of the damage pattern is required, the extraction of the corresponding spatial regions being based solely on algebra. The efficiency of the proposed approach is demonstrated numerically with an example relevant to engineering fracture. PMID:23750055

  7. Outcome after open reduction and internal fixation of intraarticular fractures of the calcaneum without the use of bone grafts

    Directory of Open Access Journals (Sweden)

    Pendse Aniruddha

    2006-01-01

    Full Text Available Background: Intraarticular fractures of calcaneum are commenest type of calcaneal fractures. Lots of controversies exist about the ideal management for them. The focus is now shifting on operative management by open reduction and internal fixation for these fractures with or without the use of bone grafts. Method: Thirty intraarticular fractures classified by Essex Lopresti radiological classification, were treated by open reduction and fixation. The patients were followed over a mean period of 30 months (25-40 months. Results: All the fractures united at a mean duration of 14 weeks. 86% patients had excellent functional outcome with one patient having fair and one having poor functional outcome. Conclusion: Open reduction and internal fixation with plate is a good method for treatment of intraarticular fractures of calcaneum to achieve anatomical restoration of articular surface under vision, stable fixation, early mobilization and an option for primary subtalar arthrodesis if deemed necessary.

  8. [An improved reduction technique for depression fractures of lateral tibial plateau].

    Science.gov (United States)

    Wang, Hongchuan; Lou, Hua; Liu, Kai; Jiang, Junwei

    2013-01-01

    To investigate the improved reduction technique for depression fractures of the lateral tibial plateau and its effectiveness. Between January 2008 and December 2010; 48 patients (48 knees) with depression fractures of the lateral tibial plateau (Schatzker II or III fractures) were treated. There were 32 males and 16 females with an average age of 45.8 years (range, 16-79 years). All fractures were fresh closed fractures, which were caused by traffic accident in 27 cases, by falling from height in 5 cases, by crushing in 8 cases, and by sustained falls in 8 cases. According to Schatzker classification, 29 cases were classified as type II and 19 cases as type III. The lateral cortex was cut off to expose the depression and compacted cancellous bone was elevated to reset the articular surface. After reduction, autologous iliac bone graft and locking plate internal fixation were used. Healing of incision by first intention was achieved in all patients, and no complication occurred. All patients were followed up 1.7 years on average (range, 1-3 years). At last follow-up, the knee extension was (-0.5 +/- 0.3) degrees, and the knee flexion was (136.9 +/- 8.8) degrees. X-ray films showed that the fracture healing time was 52 weeks and no breakage of internal fixation occurred. According to Rasmussen clinical score, the results were excellent in 35 cases, good in 10 cases, and fair in 3 cases. According to Rasmussen radiographical score, the results were excellent in 41 cases, good in 7 cases; there were 41 excellent scores and 7 good scores of articular reduction; all gained good recovery of coronal and sagittal alignment and condylar width. The articular surface collapse was (1.0 +/- 0.7) mm at immediate postoperatively and (1.2 +/- 0.7) mm at last follow-up, showing no significant difference (t = -1.42, P = 0.20), but significant differences were found when compared with that at preoperation [(12.2 +/- 8.0) mm, P fracture reduction and can avoid loss of reduction. The

  9. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  10. Reduction of rib fractures with a bioresorbable plating system: preliminary observations.

    Science.gov (United States)

    Vu, Kim-Chi; Skourtis, Mia E; Gong, Xi; Zhou, Minhao; Ozaki, Wayne; Winn, Shelley R

    2008-05-01

    Operative fixation of rib fractures can reduce morbidity and mortality. Currently, resorbable fixation devices are used in a variety of surgical procedures. A standard osteotomy was prepared in 30 New Zealand white rabbits at the 12th rib. Eighteen had surgical repair with bioresorbable plates and 12 underwent nonoperative management. Half the animals in each group were killed at 3-week postfracture and the remaining animals were killed at 6-week postfracture. Ribs were radiographed and processed histologically to assess fracture healing. Rib reduction was defined as the alignment of the rib ends in a structural condition similar to the prefractured state and quantitative radiomorphometry measured the radiopaque callus surrounding the rib injury sites. Statistical analysis was performed using Fisher's exact test and an unpaired Student's t test and significance was established at p rib fractures remained reduced in the operative group, whereas zero of six and three of six of the rib fractures remained reduced, respectively, in the nonoperative group. A statistically significant increase in radiopaque callus surrounding the rib injury sites was observed at 3 and 6 weeks in the fixed groups. Fixation of rib fractures with a bioresorbable miniplate system was superior to nonoperative treatment at the 3-week interval, with a statistically significant increase in radiopaque callus formation at both 3 and 6 weeks. Additional studies will evaluate the biomechanical outcomes and degradation tissue response after extended in vivo intervals.

  11. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  12. Update on open reduction and internal fixation of unstable pelvic fractures during pregnancy: case reports

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    Full Text Available ABSTRACT This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report: The study included four cases of pregnant women with unstable pelvic fractures; their outcomes were analyzed and discussed. Data were obtained from two University Hospitals. The mean age of women was 23 years; most (3/4 were primiparous, with a mean pregnancy age of 23 weeks. Two women had Malgaigne-type fractures and the other two had symphyseal disjunction associated with acetabular fractures. All fractures were treated surgically. One foetus was dead on admission to hospital. The other three developed well, along with their mothers. Good evolution was only possible with careful pre-, peri-, and postoperative care for the mother, as well as foetal assessment by a multidisciplinary team. In complex cases such as those presented in the present study, pre-, peri-, and postoperative care are mandatory, as well as the presence of a multidisciplinary team. The mother's life always takes priority in acute clinical pictures, as it offers the best chance of survival to both mother and child.

  13. Minimal packing duration in close reduction for nasal bone fracture treatment.

    Science.gov (United States)

    Choi, Dong Sik; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae; Choi, Kang Young

    2015-04-15

    Nasal bone fracture is the most common type of facial bone fracture. The optimal duration of the packing after closed reduction has been a controversial issue. The packing has several disadvantages such as blocking the nasal airway, causing infection and a headache, which is the most common immediate complication. The present study investigated the minimal and optimal duration of the nasal packing following reduction surgery of nasal bone fracture. A prospective study was performed for the patients undergoing reduction surgery following nasal bone fracture between July 2010 and June 2012. The patients were categorised into three groups according to the duration of nasal packing. For the patients treated between July 2010 and June 2011, nasal packing was maintained for 5 days. For those between July 2011 and December 2011, packing was maintained for 3 days. For those between January 2012 and June 2012, the packing was removed after 1 day. The computed tomography scan and the cephalolateral X-ray were checked at immediate postoperative period after packing removal and 6 months postoperatively. The alteration of heights, deviations, and nasal bone contours with time passage were compared among three groups. The patient satisfaction survey was also performed and compared. A total of 530 patients including 322 of the 5-days packing group, 102 of the 3-days group, and 106 of the 1-day group were enrolled. There was no statistically significant difference between the groups in terms of heights, deviations, and nasal bone contours (p-value ≥ 0.05). In the patient satisfaction survey, the 1-day packing group complained of discomfort related to nasal packing and headache symptoms much less, compared to the other two groups. The present study demonstrated that 1-day packing had comparable postoperative outcome with reducing the patients' discomfort. As such, a longer packing duration was not needed to achieve stable results one day is a reasonable packing time for most

  14. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  15. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases

    OpenAIRE

    St-Jean, Guy; Debowes, Richard M.

    1992-01-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.

  16. Efficacy Evaluation for the Treatment of Subcapital Femoral Neck Fracture in Young Adults by Capsulotomy Reduction and Closed Reduction

    Directory of Open Access Journals (Sweden)

    Cong Liu

    2015-01-01

    Full Text Available Background: Subcapital femoral neck fracture in young adults has many complications, and the incidence is increasing year-by-year. The selection of the proper operation method to avoid them is an ambiguous matter. This study aimed to evaluate the treatment effect of subcapital femoral neck fracture by the capsulotomy and internal fixation with iliac bone grafting or closed reduction and internal fixation in young adults. Methods: From March 2003 to February 2010, 65 young patients with subcapital femoral neck fractures were treated, including 39 males and 26 females with average age of 34.5 years (range, 19-50 years; 29 cases of the left side and 36 cases of the right side. They were randomly divided into Group A with 34 cases treated by closed reduction and internal fixation and Group B with 31 cases treated by the capsulotomy and internal fixation with iliac bone grafting. The two groups had no significant differences in sex, age, body mass index and preoperative Harris Hip Score. The observation criteria involved the length of the incision, blood loss, operation time, nonunion rate, avascular necrosis of the femoral head (ANFH rate and Harris Hip Score. Results: Four of 65 patients were lost follow-up, and the follow-up rate was 93.8%, the average follow-up time was 38.7 months (range, 33-47 months. In Group A, the incision length was 5.1 ± 2.2 cm, blood loss was 84.0 ± 13.2 ml, and operation time was 52.9 ± 10.2 min. In Group B, the incision length was 15.4 ± 4.6 cm, blood loss was 396.0 ± 21.3 ml, and operation time was 116.5 ± 15.3 min. Nonunion occurred in 8 patients (25.2% in Group A and 1 patient (3.3% in Group B. ANFH occurred in 9 patients (29.1% in Group A and 2 patients (6.7% in Group B. Postoperative Harris Hip Score was 89.0 ± 5.6 in Group A and 95.0 ± 4.5 in Group B. The above index of two groups was considered statistically significant (P < 0.05. Conclusions: Capsulotomy and internal fixation with iliac bone grafting can

  17. An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture

    OpenAIRE

    Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal

    2015-01-01

    Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable ...

  18. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    Science.gov (United States)

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without

  19. Transpedicular hydroxyapatite grafting with indirect reduction for thoracolumbar burst fractures with neurological deficit: A prospective study

    Directory of Open Access Journals (Sweden)

    Toyone Tomoaki

    2007-01-01

    Full Text Available Background: The major problem after posterior correction and instrumentation in the treatment of thoracolumbar burst fractures is failure to support the anterior spinal column leading to loss of correction of kyphosis and hardware breakage. We conducted a prospective consecutive series to evaluate the outcome of the management of acute thoracolumbar burst fractures by transpedicular hydroxyapatite (HA grafting following indirect reduction and pedicle screw fixation. Materials and Methods: Eighteen consecutive patients who had thoracolumbar burst fractures and associated incomplete neurological deficit, operatively treated within four days of admission. Following indirect reduction and pedicle screw fixation, transpedicular intracorporeal HA grafting to the fractured vertebrae was performed. Mean operative time was 125 min and mean blood loss was 150 ml. Their implants were removed within one year and were prospectively followed for at least two years. Results: The neurological function of all 18 patients improved by at least one ASIA grade, with nine (50% patients demonstrating complete neurological recovery. Sagittal alignment was improved from a mean preoperative kyphosis of 17°to -2°(lordosis by operation, but was found to have slightly deteriorated to 1° at final follow-up observation. The CT images demonstrated a mean spinal canal narrowing pre-operatively immediate post-operative and at final followup of 60%, 22% and 11%, respectively . There were no instances of hardware failure. No patient reported severe pain or needed daily dosages of analgesics at the final follow-up. The two-year postoperative MRI demonstrated an increase of one grade in disc degeneration (n = 17 at the disc above and in 11 patients below the fractured vertebra. At the final follow-up, flexion-extension radiographs revealed that a median range of motion was 4, 6 and 34 degrees at the cranial segment of the fractured vertebra, caudal segment and L1-S1, respectively

  20. [Manipulative reduction and small splint fixation combined with micromovement exercise for treatment of humeral shaft fractures].

    Science.gov (United States)

    Tang, Hao-chen; Xiang, Ming; Chen, Hang; Hu, Xiao-chuan; Yang, Guo-yong

    2016-01-01

    To investigate the therapeutic efficacy of bone-setting manipulative reduction and small splint fixation combined with micro-movement theory exercise for treatment of humeral shaft fractures. From March 2011 to February 2014, 64 cases of humeral shaft fractures were treated by bone-setting manipulative reduction and small splint fixation including 28 males and 36 females with an average age of 38.1 years old ranging from 22 to 67 years old. According to the classification of AO/OTA, there were 10 cases of type A1, 12 cases of type A2,11 cases of type A3,10 cases of type B1,12 cases of type B2, 7 cases of type B3, 2 cases of type C1, 1 case of type C2, 1 case of type C3. After close reduction early functional exercise performed according to micro-movement theory. All patients had no other parts of the fractures, neurovascular injury, and serious medical problems. Patients were followed up for fracture healing, shoulder and elbow joint function recovery, and curative effect. All patients were followed up from 10 to 12 months with an average of 10.3 months. Of them, 2 cases had a small amount of callus growth at 3 months after close reduction, so instead of operation; 2 cases appeared radial nerve symptoms after close reduction ,so instead of operation. Other patients were osseous healing, the time was 8 to 12 weeks with an average of 10.2 weeks. After osseous healing, according to Constant-Murley score system ,the average score was (93.5 ± 3.2) points, the result was excellent in 29 cases, good in 29 cases, fair in 6 cases, excellent and good rate was 90.3%; according to the Mayo score system, the average score was (93.7 ± 4.2) points, the result was excellent in 35 cases, good in 23 cases, fair in 6 cases, excellent and good rate was 91.9%. Bone-setting manipulative reduction and small splint fixation combined with micromovement theory exercise for treatment of humeral shaft fractures has advantage of positive effect, easy and inexpensive method, the treatment has

  1. Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus

    NARCIS (Netherlands)

    Wijgman, A. J.; Roolker, W.; Patt, T. W.; Raaymakers, E. L. F. B.; Marti, R. K.

    2002-01-01

    BACKGROUND: Controversy persists concerning the preferred treatment of displaced fractures of the proximal part of the humerus. The present study was undertaken to evaluate the results of open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus and

  2. Explosion Amplitude Reduction due to Fractures in Water-Saturated and Dry Granite

    Science.gov (United States)

    Stroujkova, A. F.; Leidig, M.; Bonner, J. L.

    2013-12-01

    Empirical observations made at the Semipalatinsk Test Site suggest that nuclear tests in the fracture zones left by previous explosions ('repeat shots') show reduced seismic amplitudes compared to the nuclear tests in virgin rocks. Likely mechanisms for the amplitude reduction in the repeat shots include increased porosity and reduced strength and elastic moduli, leading to pore closing and frictional sliding. Presence of pore water significantly decreases rock compressibility and strength, thus affecting seismic amplitudes. A series of explosion experiments were conducted in order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fracture zones of previously detonated explosions. Explosions in water-saturated granite were conducted in central New Hampshire in 2011 and 2012. Additional explosions in dry granite were detonated in Barre, VT in 2013. The amplitude reduction is different between dry and water-saturated crystalline rocks. Significant reduction in seismic amplitudes (by a factor of 2-3) in water-saturated rocks was achieved only when the repeat shot was detonated in the extensive damage zone created by a significantly larger (by a factor of 5) explosion. In case where the first and the second explosions were similar in yield, the amplitude reduction was relatively modest (5-20%). In dry rocks the amplitude reduction reached a factor of 2 even in less extensive damage zones. In addition there are differences in frequency dependence of the spectral amplitude ratios between explosions in dry and water-saturated rocks. Thus the amplitude reduction is sensitive to the extent of the damage zone as well as the pore water content.

  3. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Born, Christopher T. [Temple University Hospital/Temple Children' s Hospital, Temple Sports Medicine, Marlton, NJ (United States); Grudziak, Jan S. [Children' s Hospital of Pittsburgh, Department of Orthopedic Surgery, Pittsburgh, PA (United States); Towbin, Richard B.

    2004-12-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  4. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    International Nuclear Information System (INIS)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D.; Born, Christopher T.; Grudziak, Jan S.; Towbin, Richard B.

    2004-01-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  5. A remediation performance model for enhanced metabolic reductive dechlorination of chloroethenes in fractured clay till

    Science.gov (United States)

    Manoli, Gabriele; Chambon, Julie C.; Bjerg, Poul L.; Scheutz, Charlotte; Binning, Philip J.; Broholm, Mette M.

    2012-04-01

    A numerical model of metabolic reductive dechlorination is used to describe the performance of enhanced bioremediation in fractured clay till. The model is developed to simulate field observations of a full scale bioremediation scheme in a fractured clay till and thereby to assess remediation efficiency and timeframe. A relatively simple approach is used to link the fermentation of the electron donor soybean oil to the sequential dechlorination of trichloroethene (TCE) while considering redox conditions and the heterogeneous clay till system (clay till matrix, fractures and sand stringers). The model is tested on lab batch experiments and applied to describe sediment core samples from a TCE-contaminated site. Model simulations compare favorably to field observations and demonstrate that dechlorination may be limited to narrow bioactive zones in the clay matrix around fractures and sand stringers. Field scale simulations show that the injected donor is expected to be depleted after 5 years, and that without donor re-injection contaminant rebound will occur in the high permeability zones and the mass removal will stall at 18%. Long remediation timeframes, if dechlorination is limited to narrow bioactive zones, and the need for additional donor injections to maintain dechlorination activity may limit the efficiency of ERD in low-permeability media. Future work should address the dynamics of the bioactive zones, which is essential to understand for predictions of long term mass removal.

  6. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    Science.gov (United States)

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  7. Applicability and Effectiveness of Closed Reduction of Nasal Fractures under Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Vilela, Fernando

    2014-03-01

    Full Text Available Introduction A significant portion of patients treated in emergency departments have nasal fracture. It is important that the otolaryngologist know how to treat such damage. Objectives To evaluate the effectiveness of nasal fracture reduction under local anesthesia and tolerance to the procedure. Methods Twenty-four patients treated in the emergency department with closed reduction under local anesthesia were prospectively followed. Epidemiologic information and data regarding pain and complications during the management were noted. The degree of satisfaction was researched by visual analog scale. Results The majority of patients were male (75%, and the most common cause of injury was motor vehicle accident. We found a significant association between time to reduction and referred pain during the procedure. In patients in whom the procedure was delayed (over 3 days, there was less pain, and those who bled during the procedure had a shorter average time to reduction than the group of patients who did not bleed. Most patients were very satisfied, with more than 95% of these willing to undergo the same process again, if necessary. Conclusions The closed approach in the clinic under local anesthesia was effective and safe in restoration of the nose.

  8. Predictions of first passage times in sparse discrete fracture networks using graph-based reductions

    Science.gov (United States)

    Hyman, J.; Hagberg, A.; Srinivasan, G.; Mohd-Yusof, J.; Viswanathan, H. S.

    2017-12-01

    We present a graph-based methodology to reduce the computational cost of obtaining first passage times through sparse fracture networks. We derive graph representations of generic three-dimensional discrete fracture networks (DFNs) using the DFN topology and flow boundary conditions. Subgraphs corresponding to the union of the k shortest paths between the inflow and outflow boundaries are identified and transport on their equivalent subnetworks is compared to transport through the full network. The number of paths included in the subgraphs is based on the scaling behavior of the number of edges in the graph with the number of shortest paths. First passage times through the subnetworks are in good agreement with those obtained in the full network, both for individual realizations and in distribution. Accurate estimates of first passage times are obtained with an order of magnitude reduction of CPU time and mesh size using the proposed method.

  9. The hematoma block: a simple, effective technique for closed reduction of ankle fracture dislocations.

    Science.gov (United States)

    Ross, Adrianne; Catanzariti, Alan R; Mendicino, Robert W

    2011-01-01

    Management of a dislocated ankle fracture can be challenging because of instability of the ankle mortise, a compromised soft tissue envelope, and the potential neurovascular compromise. Every effort should be made to quickly and efficiently relocate the disrupted ankle joint. Within the emergency department setting, narcotics and benzodiazepines can be used to sedate the patient before attempting closed reduction. The combination of narcotics and benzodiazepines provides relief of pain and muscle guarding; however, it conveys a risk of seizure as well as respiratory arrest. An alternative to conscious sedation is the hematoma block, or an intra-articular local anesthetic injection in the ankle joint and the associated fracture hematoma. The hematoma block offers a comparable amount of analgesia to conscious sedation without the additional cardiovascular risk, hospital cost, and procedure time. Copyright © 2011 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    Science.gov (United States)

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at Pfractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  11. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    Science.gov (United States)

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  12. Do instability markers predict satisfactory reduction and requirement for later surgery in emergency department patients with wrist fracture?

    Science.gov (United States)

    Winayak, Amar; Gossat, Alyza; Cooper, Jenny; Ritchie, Peter; Lim, Wei; Klim, Sharon; Kelly, Anne-Maree

    2018-02-01

    Research suggests that the presence of instability markers in patients with displaced distal radial fractures is associated with poorer outcome. Our aims were to determine whether the presence of previously defined instability markers could predict the likelihood of successful ED reduction and requirement for a secondary procedure after ED reduction. Retrospective cohort study performed by medical record review. Adult ED patients coded as having an isolated wrist fracture and having fracture reduction in ED were eligible for inclusion. Data collected included demographics, history of osteoporosis, mechanism of injury, radiological features on X-rays and performance of a secondary procedure. Outcomes of interest were the rate of successful fracture reduction in ED (against defined radiological criteria), the rate of secondary procedures and the association between the number of defined instability risk factors and successful reduction and performance of a secondary surgical procedure. Analysis was by χ 2 test, receiver operating characteristic curve, logistic regression analyses. Three hundred and nineteen patients were studied; median age 62 years, 77% female. Sixty-five per cent of patients had satisfactory fracture reduction in ED (95% CI 59%-70%). Eighty-six patients underwent a secondary procedure to reduce/stabilise their fracture (28%, 95% CI 23%-33%). Younger age, lack of satisfactory ED reduction and increased number of instability factors were independently predictive of the performance of a secondary procedure. Instability risk factors are common in patients with wrist fractures requiring reduction in ED. The number of instability factors is not a strong predictor of the performance of secondary procedures. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  13. Consequences of quality of reduction on osteosynthesis complications and quality of life in elderly patients with subtrochanteric fracture.

    Science.gov (United States)

    Codesido-Vilar, P; Mejía-Casado, A; Riego-Fernández, J; Rodriguez-Casas, N; García-Cabanas, S; Rivas-Felice, J; García-Quevedo, L

    2018-05-18

    To compare results in terms of orthopaedic complications and quality of life in elderly patients with subtrochanteric fracture treated with intramedullary nailing according to fracture reduction status. A prospective cohort study including 90 elderly patients with subtrochanteric fractures of the femur treated with a cephalomedullary nail, with a minimum 1-year follow up. The inclusion criteria were: aged 60 years or older, without severe cognitive dysfunction and independent ambulatory capability before the fracture. We defined 3different groups in relation to fracture reduction status: good, acceptable and poor, according to modified criteria from Baumgartner et al. We compared clinical and surgical characteristics and healthy quality of life, social function and mobility according to the EQ-5D, Jensen Index and Mobility Score of Parker and Palmer questionnaires. We found differences in time to union, better in the good reduction group (P=.002); need for open reduction, more frequent in the good reduction group (P<.001), and in postoperative complications, more frequent in the poor reduction group (P=.001). We found no significant differences between the 3groups regarding scores in quality of life, social function and mobility. Reduction in subtrochanteric fractures in older people is key to obtaining better clinic and surgical results, improving time to union and decreasing surgical complications. Exposure of the focus fracture seems to be a safe manoeuvre. Quality of life had substantially deteriorated n these patients, but a there was a tendency, although not statistically significant, for it to improve in patients after good surgical reduction. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation.

    Science.gov (United States)

    Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka

    2016-01-01

    Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.

  15. Oral-motor and electromyographic characterization of patients submitted to open a nd closed reductions of mandibular condyle fracture.

    Science.gov (United States)

    Silva, Amanda Pagliotto da; Sassi, Fernanda Chiarion; Andrade, Claudia Regina Furquim de

    To characterize the oral-motor system of adults with mandibular condyle facture comparing the performance of individuals submitted to open reduction with internal fixation (ORIF) and closed reduction with mandibulomaxillary fixation (CRMMF). Study participants were 26 adults divided into three groups: G1 - eight individuals submitted to ORIF for correction of condyle fracture; G2 - nine individuals submitted to CRMMF for correction of condyle fracture; CG - nine healthy volunteers with no alterations of the orofacial myofunctional system. All participants underwent the same clinical protocol: assessment of the orofacial myofunctional system; evaluation of the mandibular range of motion; and surface electromyography (sEMG) of the masticatory muscles. Results indicated that patients with condyle fractures from both groups presented significant differences compared with those from the control group in terms of mobility of the oral-motor organs, mastication, and deglutition. Regarding the measures obtained for mandibular movements, participants with facial fractures from both groups showed significant differences compared with those from the control group, indicating greater restrictions in mandibular motion. As for the analysis of sEMG results, G1 patients presented more symmetrical masseter activation during the task of maximal voluntary teeth clenching. Patients with mandibular condyle fractures present significant deficits in posture, mobility, and function of the oral-motor system. The type of medical treatment does not influence the results of muscle function during the first six months after fracture reduction. Individuals submitted to ORIF of the condyle fracture present more symmetrical activation of the masseter muscle.

  16. An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture.

    Science.gov (United States)

    Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal

    2015-01-01

    Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable plates. Different methods have various pros and cons. The choice of anesthesia is also very crucial sometimes. This case report describes a new method of closed reduction with 18 gauge needle simulated as an arch bar performed under local anaesthesia.

  17. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    Science.gov (United States)

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  18. Closed reduction of displaced or dislocated mandibular condyle fractures in children using threaded Kirschner wire and external rubber traction.

    Science.gov (United States)

    Kim, J H; Nam, D H

    2015-10-01

    Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    Science.gov (United States)

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  20. Use of a Hybrid Operating Room to Improve Reduction of Syndesmotic Injuries in Ankle Fractures: A Case Report.

    Science.gov (United States)

    Cancienne, Jourdan M; Crosen, Matelin P; Yarboro, Seth R

    2016-01-01

    Ankle fractures are one of the most common orthopedic injuries requiring operative treatment, and approximately 1 in 4 ankle fractures will have an associated distal tibiofibular syndesmosis disruption. Syndesmotic reduction is crucial to restoring ankle function and preventing the development of arthritis. The hybrid operating room provides 3-dimensional intraoperative imaging capabilities that can enable the surgeon to ensure the syndesmosis is appropriately reduced, particularly by comparing it with the contralateral ankle. By confirming the syndesmosis reduction intraoperatively, the risk of a return to the operating room for revision surgery is decreased. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  2. Open reduction and internal fixation of intra-articular fractures of the mandibular condyle: our first experiences.

    Science.gov (United States)

    Vesnaver, Ales

    2008-10-01

    Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.

  3. Open reduction and internal fixation of dislocated condylar fractures in children: long-term clinical and radiologic outcomes.

    Science.gov (United States)

    Deleyiannis, Frederic W-B; Vecchione, Lisa; Martin, Brian; Jiang, Shao; Sotereanos, George

    2006-11-01

    The purpose of this study was to investigate the long-term clinical and radiologic outcomes of treating dislocated condylar fractures sustained in childhood with open reduction and internal fixation (ORIF). Six children 14 years or younger with a condylar neck or subcondylar fracture with dislocation of the condyle from the glenoid fossa were treated with ORIF. Patients were followed for 27 to 92 months post-ORIF (mean: 67.6 months) with routine clinical and radiologic examinations. On the dislocated side, all patients radiographically showed signs of remodeling of the condylar process and shortening of the ramus. Subsequent to their fractures, 3 patients were classified with Angle class II malocclusion, retrognathism, and deviation of the mandibular symphysis. Four patients had objective and/or subjective signs of temporomandibular (TMJ) dysfunction. Until open surgery demonstrates a consistent functional advantage, nonsurgical management should be considered the first treatment option for the dislocated pediatric condylar fracture.

  4. Percutaneous clamping of spiral and oblique fractures of the tibial shaft: a safe and effective reduction aid during intramedullary nailing.

    Science.gov (United States)

    Collinge, Cory A; Beltran, Michael J; Dollahite, Henry A; Huber, Florian G

    2015-06-01

    The reduction of tibial shaft fractures during intramedullary nailing is important if limb alignment is to be restored and successful clinical outcomes are expected. We have used a percutaneously applied (or open) clamp or clamps to achieve and maintain reduction during nailing of all amendable tibial shaft fractures. In this article, we describe the technique and preliminary results comparing closed, simple spiral and oblique tibial shaft fractures (OTA 42-A1 and A2) managed with percutaneous clamp-assisted nailing (CAN) versus nailing using manual reduction (MRN) held by the surgical team. In the MRN group, there were an increased fracture gap (P = 0.04) and trends toward malalignment (P = 0.07) and healing time (P = 0.06) compared with the CAN group. There were also trends in clinical; no wound complications occurred in either group. We have found that percutaneous CAN of closed, simple spiral and oblique tibial shaft fractures seems safe and allows for early predictable union with reproducible alignment compared with nailing using MRN.

  5. Over-extending reduction combined with unilateral approach percutaneous vertebroplasty for the treatment of vertebral compression fractures due to osteoporosis

    International Nuclear Information System (INIS)

    Wei Xinjian; Ji Xianghui; Cao Fei; Zhang Fuhua

    2012-01-01

    Objective: To assess the clinical effect of over-extending reduction combined with percutaneous vertebroplasty (PVP) in treating vertebral compression fractures caused by osteoporosis. Methods: A total of 16 patients with vertebral compression fractures due to osteoporosis were treated with over-extending reduction by using traction on the operation table, and then PVP through trans-single-pedicular approach was performed on the fractured vertebra. The visual analogue scale (VAS) was used to evaluate the clinical effectiveness. The preoperative and postoperative heights of the fractured vertebral body were determined, and the vertebral height recovery ratio was calculated. Results: Technical success was achieved in 20 vertebrae of 16 cases. Bone cement leakage was observed in front of the vertebral body (n=5), in the side of vertebral body (n=20) and within the intervertebral (n=2). After the treatment VAS score decreased from preoperative 8.5±1.2 to postoperative 2.5±1.4. The vertebral height recovery ratio was (40.1±23.5)%. After the surgery, the VAS score and the vertebral height were significantly improved (P<0.05). Conclusion: The over-extending reduction combined with PVP through trans-single-pedicular approach is an effective treatment for vertebral compression fractures caused by osteoporosis. (authors)

  6. Avaliação da força de preensão e funcionalidade após fratura distal de rádio/Evaluation of strength and functionality after distal radius fracture

    Directory of Open Access Journals (Sweden)

    Bruno Goto Kimura

    2017-09-01

    Full Text Available Esse estudo teve objetivo avaliar se existe diferença em relação a força de preensão e funcionalidade de pacientes com fratura distal de rádio em relação ao gênero e ao tipo de tratamento (conservador e cirúrgico. Os pacientes recrutados para este estudo foram divididos em dois grupos, grupo de homens (G1 e grupo de mulheres (G2. Todos os voluntários realizaram uma única avaliação da força de preensão palmar e a avaliação funcional pelos questionários Disability of the Arm, Shoulder and Hand (DASH e Patient Rated Wrist Evaluation (PRWE.Os valores de força de preensão foram significativamente (p<0,000 menores no grupo de mulheres 5,42 (±3,42 e no tratamento conservador 5,20 (±4,91 quando comparados aos homens 16,01 (±6,86 e ao tratamento cirúrgico 12,28 (±7,56. Enquanto que os valores de incapacidade, avaliados pelos questionários DASH e PRWE, foram maiores no grupo de mulheres e pacientes que realizaram tratamento conservador, porém não foram encontradas diferenças significativas. As fraturas distais de rádio se não reabilitadas precocemente podem comprometer a amplitude de movimento, a força muscular, a precisão, a destreza e controle dos movimentos. Neste caso, os questionários de funcionalidade são um parâmetro importante que refletem o desempenho do indivíduo durante a realização de atividades de vida diária, sendo que quanto pior os escores, pior o desempenho e autonomia desses pacientes. Nesse estudo, podemos concluir que o gênero e o tipo de tratamento influenciaram na diminuição da força de preensão e na maior incapacidade funcional na avaliação inicial após 45 dias da fratura. AbstractThis study had the objective of evaluating whether there is a difference in the grip strength and functionality of patients with distal radius fracture in relation to gender and type of treatment (conservative and surgical. The patients recruited for this study were divided into two groups, group of men (G1

  7. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    Science.gov (United States)

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  8. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  9. Gravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures

    Directory of Open Access Journals (Sweden)

    Lauren Ehrlichman

    2017-03-01

    Full Text Available Background: While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a novel view, the Gravity Reduction View (GRV, which helps elucidate non-anatomic positioning and reducibility of the mortise.Methods: The patient is positioned lateral decubitus with the injured leg elevated on a holder with the fibula directed superiorly. The x-ray cassette is placed posterior to the heel, with the beam angled at 15˚ of internal rotation to obtain a mortise view. Our proposed treatment algorithm is based upon the measurement of the medial clear space (MCS on the GRV versus the static mortise view (and in comparison to the superior clear space (SCS and is based on reducibility of the MCS. A retrospective review of patients evaluated utilizing the GRV was performed.Results: 26 patients with Weber B fibula fractures were managed according to this treatment algorithm. Mean age was 50.57 years old (range: range:18-81, SD=19. 17 patients underwent operative treatment and 9 patients were initially treated nonoperatively. 2 patients demonstrated late displacement and were treated surgically. Using this algorithm, at a mean follow-up of 26 weeks, all patients had a final MCS that was less than the SCS (final mean MCS 2.86 mm vs. mean SCS of 3.32 indicating effectiveness of the treatment algorithm.Conclusion: The GRV is a novel radiographic view in which deltoid competency, reducibility and initial positioning of the mortise are assessed by comparing a static mortise view with the appearance of the mortise on the GRV. We have developed a treatment algorithm based on the GRV and have found it to be useful in guiding treatment and successful at achieving anatomic mortise alignment.

  10. Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Marianne

    2015-01-01

    BACKGROUND: Operative treatment of displaced calcaneal fractures should restore joint congruence, but conventional fluoroscopy is unable to fully visualize the subtalar joint. We questioned whether intraoperative 3-dimensional (3D) imaging would aid in the reduction of calcaneal fractures......, resulting in improved articular congruence and implant positioning. METHOD: Sixty-two displaced calcaneal fractures were operated on using standard fluoroscopic views. When the surgeon had achieved a satisfactory reduction, an intraoperative 3D scan was conducted, malreductions or implant imperfections were...

  11. Clinical comparison between the retromandibular approach for reduction and fixation and endoscope-assisted open reduction and internal fixation for mandibular condyle fractures.

    Science.gov (United States)

    Nogami, Shinnosuke; Takahashi, Tetsu; Yamauchi, Kensuke; Miyamoto, Ikuya; Kaneuji, Takeshi; Yamamoto, Noriaki; Yoshiga, Daigo; Yamashita, Yoshihiro

    2012-11-01

    Endoscope-assisted transoral open reduction and internal fixation (EAORIF) for mandibular condyle fractures has recently become popular because it is minimally invasive, provides excellent visibility without a large incision, and reduces surgical scarring and the risk of facial nerve injury. This report describes a retrospective clinical study that compared certain clinical parameters, including postoperative function, between the retromandibular (RM) approach and EAORIF. Fifteen patients were treated by the RM approach, whereas 15 underwent EAORIF between July 2006 and September 2011 at Kyushu Dental College, Japan. Clinical indices comprised fracture line, fracture type, number of plates used, surgical duration, bleeding amount, and functional items, including maximum interincisal opening, mandibular deviation on the opening pathway, malocclusion, facial paresthesia, and temporomandibular joint pain and clicking. The areas subjected to either approach included lower neck and subcondyle. The RM approach was used for mandibular condyle fractures with dislocation of a small bone segment. Both groups used 2 plates in all cases. Surgical duration, maximum interincisal opening, mandibular deviation, occlusion, and temporomandibular joint function at 6 months after surgery were comparable between groups. The average bleeding amount in the EAORIF group was greater than in the RM group. One patient from the RM group developed facial paresthesia that persisted for 6 months after surgery. It was concluded that surgical treatment was suitable for fractures of the lower neck and subcondylar. Both procedures showed good results in the functional items of this study.

  12. MRI diagnosis of trapped periosteum following incomplete closed reduction of distal tibial Salter-Harris II fracture

    International Nuclear Information System (INIS)

    Raman, Subha; Wallace, E.C.

    2011-01-01

    Irreducible fracture of the distal tibial physis due to interposed soft tissue including periosteum is well documented in the orthopedic literature but is uncommon. This condition has been associated with subsequent growth disturbance and requires open reduction. There are very few prior reports of MRI depiction of soft tissue interposition and none of periosteal interposition in the distal tibial physis. This is a relatively common location of physeal injury and related growth disturbance. We present a case of periosteum trapped in the distal tibial physis, diagnosed on MRI, in a Salter-Harris II fracture and its management implications. (orig.)

  13. Spectral radius of graphs

    CERN Document Server

    Stevanovic, Dragan

    2015-01-01

    Spectral Radius of Graphs provides a thorough overview of important results on the spectral radius of adjacency matrix of graphs that have appeared in the literature in the preceding ten years, most of them with proofs, and including some previously unpublished results of the author. The primer begins with a brief classical review, in order to provide the reader with a foundation for the subsequent chapters. Topics covered include spectral decomposition, the Perron-Frobenius theorem, the Rayleigh quotient, the Weyl inequalities, and the Interlacing theorem. From this introduction, the

  14. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  15. Posttraumatic Proximal Radioulnar Synostosis after Closed Reduction for a Radial Neck and Olecranon Fracture

    Directory of Open Access Journals (Sweden)

    Patrick R. Keller

    2018-01-01

    Full Text Available Posttraumatic proximal radioulnar synostosis (PPRUS is a severe complication of radial head and neck fractures known to occur after severe injury or operative fixation. Cases of PPRUS occurring after minimally displaced, nonoperatively treated radial neck injuries are, by contrast, extremely rare. Here, we present a pediatric case of PPRUS that developed after a nonoperatively treated minimally displaced radial neck fracture with concomitant olecranon fracture. While more cases are needed to establish the association between this pattern of injury and PPRUS, we recommend that when encountering patients with a minimally displaced radial neck fracture and a concomitant elbow injury, the rare possibility of developing proximal radioulnar synostosis should be considered.

  16. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  17. Triceps-sparing approach for open reduction and internal fixation of neglected displaced supracondylar and distal humeral fractures in children.

    Science.gov (United States)

    Rizk, Ahmed Shawkat

    2015-06-01

    Supracondylar humeral fractures are one of the most common skeletal injuries in children. In cases of displacement and instability, the standard procedure is early closed reduction and percutaneous Kirschner wire fixation. However, between 10 and 20 % of patients present late. According to the literature, patients with neglected fractures are those patients who presented for treatment after 14 days of injury. The delay is either due to lack of medical facilities or social and financial constraints. The neglected cases are often closed injuries with no vascular compromise. However, the elbow may still be tense and swollen with abrasions or crusts. In neglected cases, especially after early appearance of callus, there is no place for closed reduction and percutaneous pinning. Traditionally, distal humeral fractures have been managed with surgical approaches that disrupt the extensor mechanism with less satisfactory functional outcome due to triceps weakness and elbow stiffness. The aim of this study is to evaluate the outcome of delayed open reduction using the triceps-sparing approach and Kirschner wire fixation for treatment of neglected, displaced supracondylar and distal humeral fractures in children. This prospective study included 15 children who had neglected displaced supracondylar and distal humeral fractures. All patients were completely evaluated clinically and radiologically before intervention, after surgery and during the follow-up. The follow-up period ranged from 8 to 49 months, with a mean period of 17 months. Functional outcome was evaluated according to the Mayo Elbow Performance Index (MEPI) and Mark functional criteria. All fractures united in a mean duration of 7.2 weeks (range 5-10 weeks) with no secondary displacement or mal-union. Excellent results were found at the last follow-up in 13 of the 15 patients studied (86.66 %), while good results were found in two patients (13.33 %) according to the MEPI scale. According to the Mark

  18. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    Science.gov (United States)

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  19. Pain reduction after percutaneous vertebroplasty for myeloma-associated vertebral fractures

    DEFF Research Database (Denmark)

    Simony, Ane; Hansen, Emil Jesper; Gaurilcikas, Marius

    2014-01-01

    INTRODUCTION: Percutaneous vertebroplasty (PVP) is a minimally invasive procedure with cement augmentation of vertebral fractures. It was introduced in 1987 as a treatment for painful haemangiomas and is today mostly used for painful osteoporotic fractures of the spine. Two randomised, double...

  20. Ununited fracture neck of femur treated with closed reduction and internal fixation with cancellous screw and fibular strut graft

    Directory of Open Access Journals (Sweden)

    Singh Daria

    2006-01-01

    Full Text Available Background: Ununited fracture neck of femur in young adults has been tackled in various ways. Methods: Twenty five patients of ununited fracture neck of femur in age group 21-55 years were treated by closed reduction, cancellous screw fixation and fibular strut graft and followed up for 2-6 years. Time gap between injury and operation was 6 weeks to 58 weeks. Five cases were previously fixed with various fixation devices. Results: Osseous union was achieved in 24 cases with average time of 18.16 weeks. Main complication encountered in follow-up was avascular necrosis of femoral head, others were joint stiffness and shortening. Functional end results were good to excellent in 24 cases. Conclusion: Closed reduction with internal fixation by cancellous screw and fibular strut grafting is easy and useful procedure.

  1. Open reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.

    Science.gov (United States)

    Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James

    2013-01-01

    Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.

  2. The proton radius puzzle

    Science.gov (United States)

    Bonesini, Maurizio

    2017-12-01

    The FAMU (Fisica degli Atomi Muonici) experiment has the goal to measure precisely the proton Zemach radius, thus contributing to the solution of the so-called proton radius "puzzle". To this aim, it makes use of a high-intensity pulsed muon beam at RIKEN-RAL impinging on a cryogenic hydrogen target with an high-Z gas admixture and a tunable mid-IR high power laser, to measure the hyperfine (HFS) splitting of the 1S state of the muonic hydrogen. From the value of the exciting laser frequency, the energy of the HFS transition may be derived with high precision ( 10-5) and thus, via QED calculations, the Zemach radius of the proton. The experimental apparatus includes a precise fiber-SiPMT beam hodoscope and a crown of eight LaBr3 crystals and a few HPGe detectors for detection of the emitted characteristic X-rays. Preliminary runs to optimize the gas target filling and its operating conditions have been taken in 2014 and 2015-2016. The final run, with the pump laser to drive the HFS transition, is expected in 2018.

  3. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation.

    Science.gov (United States)

    Simon, A-L; Apostolou, N; Vidal, C; Ferrero, E; Mazda, K; Ilharreborde, B

    2018-02-01

    Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. IV.

  4. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    Science.gov (United States)

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  5. Closed reduction and fluoroscopic-assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats.

    Science.gov (United States)

    Boekhout-Ta, Christina L; Kim, Stanley E; Cross, Alan R; Evans, Richard; Pozzi, Antonio

    2017-01-01

    To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. Retrospective study. Client-owned dogs (n = 37) and cats (n = 4). Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classification, preoperative and postoperative displacement), surgical information (implant size, surgical duration), and outcome assessment information (functional outcome, radiographic outcome, and complications). The majority of animals (92%) were classified as full functional outcome. No significant predictors of functional outcome were identified. The overall complication rate was 15% (n = 6). Elective pin removal rate was 41% (n = 17). Goniometry and limb circumference measurements of the affected and contralateral limbs were not significantly different in dogs for which measurements were obtained. Seventeen of 18 animals (16 dogs, 2 cats) measured had bone length changes on follow-up radiographs. FAPP is associated with an excellent functional outcome in a narrow selection of fracture configurations, specifically those with minimal displacement and for which anatomical alignment can be achieved with closed reduction. © 2016 The American College of Veterinary Surgeons.

  6. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    Science.gov (United States)

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  7. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    Science.gov (United States)

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  8. Integration of computer-assisted fracture reduction system and a hybrid 3-DOF-RPS mechanism for assisting the orthopedic surgery

    Science.gov (United States)

    Irwansyah; Sinh, N. P.; Lai, J. Y.; Essomba, T.; Asbar, R.; Lee, P. Y.

    2018-02-01

    In this paper, we present study to integrate virtual fracture bone reduction simulation tool with a novel hybrid 3-DOF-RPS external fixator to relocate back bone fragments into their anatomically original position. A 3D model of fractured bone was reconstructed and manipulated using 3D design and modeling software, PhysiGuide. The virtual reduction system was applied to reduce a bilateral femoral shaft fracture type 32-A3. Measurement data from fracture reduction and fixation stages were implemented to manipulate the manipulator pose in patient’s clinical case. The experimental result presents that by merging both of those techniques will give more possibilities to reduce virtual bone reduction time, improve facial and shortest healing treatment.

  9. Open Reduction and Internal Fixation of displaced Supracondylar Fractures of Humerus with Crossed K-wires via Medial Approach

    Directory of Open Access Journals (Sweden)

    S Hussain

    2014-07-01

    Full Text Available This study aimed at evaluating the medial approach for open reduction and internal fixation of Gartland type 3 displaced supracondylar fractures of humerus in children. A prospective, single centre study of on displaced supracondylar humerus fractures in 42 children was carried out at our institute. All fractures were managed with open reduction and internal fixation with crossed K-wires via medial approach. The mean follow-up was 12 months and patients were assessed according to Flynn’s criteria. No patients had post-operative ulnar nerve injury. Cubitus varus was not seen in any patient. Superficial pin tract infection occurred in three patients that subsided with anti-septic dressings and antibiotics. No deep infection occurred. 88.09 % patients showed satisfactory results as per Flynn’s criteria. The medial approach provides an excellent view of the supracondylar area. The approach is convenient due to a lower risk for ulnar nerve injury and better acceptability of the medial incisional scar.

  10. Open Reduction With K-Wire Stabilization of Fracture Dislocations of the Mandibular Condyle: A Retrospective Review.

    Science.gov (United States)

    Haghighi, Kayvon; Manolakakis, Manolis G; Balog, Connor

    2017-06-01

    The aim of this study was to determine the feasibility of direct transcortical stabilization of fracture dislocations of the mandibular condyle (FDMCs) using narrow-diameter non-threaded Kirschner wire (K-wire). This retrospective review reports on the treatment outcomes for 12 patients (15 fractures) with FDMCs treated with open reduction using transcortical 0.027-inch K-wire stabilization. Postoperative parameters of relevance included infection, facial nerve function, hardware removal, mandibular range of motion, and radiographic determination of fracture union. Three patients had bilateral FDMCs and 9 had unilateral FDMCs (age range at time of injury, 14 to 72 yr; mean age, 32 yr). Postoperative follow-up ranged from 6 weeks to 2 years. Four patients required removal of K-wire hardware for different reasons. K-wires were removed because of infection in 1 patient. Another patient required removal because of migration of the pin into the joint space. One pin was removed electively and another was removed for nonspecific postoperative symptoms that resolved after pin removal. Persistent facial nerve deficit was observed in 1 patient. Open reduction with transcortical K-wire stabilization can achieve satisfactory outcomes for the treatment of FDMC. Further investigation is needed in determining the efficacy of this fixation technique in the management of FDMC. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Emergency Closed Reduction of a C4/5 Fracture Dislocation with Complete Paraplegia Resulting in Profound Neurologic Recovery

    Directory of Open Access Journals (Sweden)

    Christian W. Müller

    2013-01-01

    Full Text Available Introduction. Cervical spinal cord injuries due to traumatic fractures are associated with persistent neurological deficits. Although clinical evidence is weak, early decompression, defined as <24–72 h, has been frequently proposed. Animal studies show better outcomes after early decompression within one hour or less, which can hardly ever be achieved in clinical practice. Case Presentation. A 37-year-old patient was hospitalized after being hit by a shying horse. After diagnosis of C4/5 fracture dislocation and complete paraplegia, she was intubated and sedated with deep relaxation. Emergency reduction was performed at approximately 120 minutes after trauma. Subsequently, a standard anterior decompression, discectomy, and fusion were carried out. She was then transferred to a specialized rehabilitation hospital. Her neurologic function improved from AIS grade A on admission to grade B postoperatively and grade D after four months of rehabilitation. One year after the accident, she was ambulatory without walking aids and restarted horse riding. Discussion and Conclusion. Rarely in clinical practice, decompression of the spine canal can be performed as early as in this case. This case highlights the potential benefit of utmost early reduction in cervical fracture dislocations with compression of the spinal cord.

  12. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    OpenAIRE

    Samir Joshi; Rajesh Kshirsagar; Akshay Mishra; Rahul Shah

    2015-01-01

    Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plate...

  13. Surgical site infection after open reduction and internal fixation of tibial plateau fractures.

    Science.gov (United States)

    Lin, Shishui; Mauffrey, Cyril; Hammerberg, E Mark; Stahel, Philip F; Hak, David J

    2014-07-01

    The aim of this study was to identify risk factors for surgical site infections and to quantify the contribution of independent risk factors to the probability of developing infection after definitive fixation of tibial plateau fractures in adult patients. A retrospective analysis was performed at a level I trauma center between January 2004 and December 2010. Data were collected from a review of the patient's electronic medical records. A total of 251 consecutive patients (256 cases) were divided into two groups, those with surgical site infections and those without surgical site infections. Preoperative and perioperative variables were compared between these groups, and risk factors were determined by univariate analyses and multivariate logistic regression. Variables analyzed included age, gender, smoking history, diabetes, presence of an open fracture, presence of compartment syndrome, Schatzker classification, polytrauma status, ICU stay, time from injury to surgery, use of temporary external fixation, surgical approach, surgical fixation, operative time, and use of a drain. The overall rate of surgical site infection after ORIF of tibial plateau fractures during the 7 years of this study was 7.8% (20 of 256). The most common causative pathogens was Staphylococcus aureus (n=15, 75%). Independent predictors of surgical site infection identified by multivariate analyses were open tibial plateau fracture (odds ratio=3.9; 95% CI=1.3-11.6; p=0.015) and operative time (odds ratio=2.7; 95% CI=1.6-4.4; psite infection. Both open fracture and operative time are independent risks factors for postoperative infection.

  14. A novel closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation for mallet fractures.

    Science.gov (United States)

    Shimura, Haruhiko; Wakabayashi, Yoshiaki; Nimura, Akimoto

    2014-03-01

    Some patients with mallet fractures who undergo extension block pinning complain of exposed wires, which delay their return to sports and causes inconvenience while performing tasks that require the use of hands during the early postoperative period. The purpose of this retrospective study was to present and evaluate a novel surgical procedure for mallet fractures. We treated 20 patients (14 males and six females; mean age, 38.4 years; range 17-68 years) with displaced mallet fractures involving >30 % of the articular surface using the closed reduction and microscrew fixation between January 2009 and January 2012. The distal interphalangeal joint (DIP) joint was immobilized with a splint for 1-3 weeks on an individual case basis. According to Wehbe and Schneider's classification, there were 12 type IB, six type IIB, and two type IA fractures. The mean follow-up duration was 12.6 months (range 6-31 months). Bone union was achieved in all patients within a mean period of 6.8 weeks, with no incidence of infection, skin necrosis, permanent nail deformity, or secondary osteoarthritis. Only two complications-temporary nail ridging in one patient and a dorsal bump caused by the screw in one patient-were observed. Minimum postoperative displacement was observed in one patient, for whom immobilization with a splint was continued for 4 weeks. Articular incongruity was <1.0 mm in four patients and 1.0-2.0 mm in two patients. Mean DIP joint extension loss was 6.5° and mean flexion was 67.8°. The surgical outcomes were excellent in seven patients, good in nine, and fair in four according to Crawford's evaluation criteria. Our novel surgical procedure combining closed reduction with extension block and flexion block using Kirschner wires and microscrew fixation produces good clinical results with relatively few complications.

  15. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    Directory of Open Access Journals (Sweden)

    Samir Joshi

    2015-01-01

    Full Text Available Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  16. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    Science.gov (United States)

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  17. Use of intra-medullary stacked nailing in the reduction of proximal plastic deformity in a pediatric Monteggia fracture: a case report

    Directory of Open Access Journals (Sweden)

    Huntley James S

    2011-04-01

    Full Text Available Abstract Introduction In a Monteggia fracture dislocation, it is important to reduce the ulnar fracture completely. Extensive plastic deformation of the proximal ulna may make reduction by closed manipulation impossible. Case presentation We report the case of a four-year-old Caucasian boy in whom the plastic deformation of the proximal ulna was reduced, and this reduction was maintained, using intra-medullary stacked nailing. Conclusion The technique of stacked nailing is a useful addition to the armamentarium in the management of the potentially awkward Monteggia fracture.

  18. [The randomized controlled trial of the treatment for clavicular fracture by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation].

    Science.gov (United States)

    Bi, Hong-zheng; Yang, Mao-qing; Tan, Yuan-chao; Fu, Song

    2008-07-01

    To study the curative effect and safety of rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation in treating clavicular fracture. All 201 cases of clavicular fractures were randomly divided into treatment group (101 cases) and control group (100 cases). The treatment group was treated by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation. The control group was treated by open reduction and internal fixation with Kirschner pin. All cases were followed up for 4 to 21 months (mean 10.6 months). SPSS was used to analyze clinic healing time of fracture and shoulder-joint function in both two groups. After operation, 101 cases of treatment group achieved union of fracture and the clinical healing time was 28 to 49 days (mean 34.5+/-2.7 days). In control group,there were 4 cases with nonunion of fracture,the other 96 cases were union,the clinical healing time was 36 to 92 days (mean 55.3+/-4.8 days). The excellent and good rate of shoulder-joint function was 100% in treatment group and 83% in control group. By t-test and chi2-test, there was significant difference between the two groups in curative effect (Pmanual reduction with forceps holder and retrograde pinning transfixation can be used in various kinds of clavicular shaft fracture, with many virtues such as easy operation, reliable fixation, short union time of fracture, good functional recovery of shoulder-joint and no incision scar affecting appearance.

  19. Wound infections following open reduction and internal fixation of calcaneal fractures with an extended lateral approach

    NARCIS (Netherlands)

    Backes, Manouk; Schepers, Tim; Beerekamp, M. Suzan H.; Luitse, Jan S. K.; Goslings, J. Carel; Schep, Niels W. L.

    2014-01-01

    Post-operative wound infections (PWI) following calcaneal fracture surgery can lead to prolonged hospital stay and additional treatment with antibiotics, surgical debridement or implant removal. Our aim was to determine the incidence of superficial and deep PWI and to identify risk factors (RF).

  20. High strength, biodegradable and cytocompatible alpha tricalcium phosphate-iron composites for temporal reduction of bone fractures.

    Science.gov (United States)

    Montufar, E B; Casas-Luna, M; Horynová, M; Tkachenko, S; Fohlerová, Z; Diaz-de-la-Torre, S; Dvořák, K; Čelko, L; Kaiser, J

    2018-04-01

    In this work alpha tricalcium phosphate (α-TCP)/iron (Fe) composites were developed as a new family of biodegradable, load-bearing and cytocompatible materials. The composites with composition from pure ceramic to pure metallic samples were consolidated by pulsed electric current assisted sintering to minimise processing time and temperature while improving their mechanical performance. The mechanical strength of the composites was increased and controlled with the Fe content, passing from brittle to ductile failure. In particular, the addition of 25 vol% of Fe produced a ceramic matrix composite with elastic modulus much closer to cortical bone than that of titanium or biodegradable magnesium alloys and specific compressive strength above that of stainless steel, chromium-cobalt alloys and pure titanium, currently used in clinic for internal fracture fixation. All the composites studied exhibited higher degradation rate than their individual components, presenting values around 200 μm/year, but also their compressive strength did not show a significant reduction in the period required for bone fracture consolidation. Composites showed preferential degradation of α-TCP areas rather than β-TCP areas, suggesting that α-TCP can produce composites with higher degradation rate. The composites were cytocompatible both in indirect and direct contact with bone cells. Osteoblast-like cells attached and spread on the surface of the composites, presenting proliferation rate similar to cells on tissue culture-grade polystyrene and they showed alkaline phosphatase activity. Therefore, this new family of composites is a potential alternative to produce implants for temporal reduction of bone fractures. Biodegradable alpha-tricalcium phosphate/iron (α-TCP/Fe) composites are promising candidates for the fabrication of temporal osteosynthesis devices. Similar to biodegradable metals, these composites can avoid implant removal after bone fracture healing, particularly in

  1. Comparative study of the prognosis of an extracorporeal reduction and a closed treatment in mandibular condyle head and/or neck fractures.

    Science.gov (United States)

    Park, Jung-Min; Jang, Yong-Wook; Kim, Seong-Gon; Park, Young-Wook; Rotaru, Horatiu; Baciut, Grigore; Hurubeanu, Lucia

    2010-12-01

    The objective of this study was a comparison of the prognosis between an extracorporeal reduction technique and closed treatment of a mandibular condyle fracture. The relationship between condylar resorption and several clinical variables was also studied. Seventy-one patients who had a mandibular condyle fracture took part in this study. Thirty-five patients (female: 7, male: 28, age: 30.46 ± 14.27 years) were treated by extracorporeal reduction, and 36 patients (male: 24, female: 12, age: 24.28 ± 9.99 years) were treated using a closed treatment. The presence of complications such as condylar resorption, malocclusion, nerve disorder, and disc displacement was evaluated with panoramic radiographs and clinical examinations 12 months after treatment. The relationships between the complications and other clinical variables were evaluated statistically. The anatomic site and fracture type were closely related to condyle resorption in the bivariate analysis. Condylar head fractures showed significantly higher condyle resorption than condylar neck fractures (P = .023). A complex or compound fracture showed significantly higher condyle resorption compared with a simple fracture (P = .006). Patients who had a complex/compound fracture were 34.366 times more likely to have condyle resorption compared with those who had a simple fracture (P = .002). The patient's age and treatment method were also significant predictors for condyle resorption. Fracture type was the strongest predictor of condylar resorption. Because treatment method and patient age were also related to the prognosis, the optimal treatment for mandibular condylar head and/or neck fractures should be individualized according to the patient's condition. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Is Closed Manipulative Reduction and Percutaneous Kirschner Wiring of Supracondylar Humeral Fracture in Children as Day-Care Surgery a Safe Procedure ?

    Directory of Open Access Journals (Sweden)

    Ashok R Nayak

    2013-07-01

    Full Text Available INTRODUCTION: Supracondylar fracture of the humerus is a common injury in children. It accounts for 60% of fractures around the elbow children. If the fracture is not treated properly it may give rise to many complications like malunion, Volkmann’s ischemic contracture, nerve injury, arterial injury, skin slough, heterotopic bone formation , and stiffness of elbow. The management of displaced supracondylar fracture of the elbow is one of the most difficult of the many fractures seen in children. The purpose of the study was to evaluate the anatomical and functional results of treatment of supracondylar fractures of humerus with closed reduction and percutaneous ‘K’ wire fixation as a day care procedure and record associated complications, thus decreasing the cost of treating these fractures and hospitalization. METHODS: Fifty displaced closed extension type supracondylar fractures (Gartland’s type III of the humerus in children were treated by closed reduction and percutaneous fixation with Kirschner wires. All the patients selected for this study had been treated in a day care unit and were discharged in the same evening and followed up at 3 and 6 weeks and 3 months. Open fractures, fractures with neurovascular complications and children older than 15 yrs were excluded. The final results were evaluated by Flynn’s criteria. RESULTS: The majority (72%, of the patients had fracture displaced posteomedially, Fourty one of the fifty patients had satisfactory results. The majority of the patients were male, and the average age was 8-9 years. CONCLUSION: Percutaneous fixation of supracondylar humerus done as a day care procedure is an acceptable modality of treatment and reduces the duration of hospital stay for the patient.

  3. Evaluation of Outcomes of Open Reduction and Internal Fixation Surgery in Patients with Type C Distal Humeral Fractures

    Directory of Open Access Journals (Sweden)

    Mohammadhadi Nouraei

    2018-01-01

    Full Text Available Background: In this study, functional state of patients with Type C distal humerus fractures undergone surgical plating was evaluated 6 and 12 months after the surgery in order to record postsurgical factors such as pain level and job/performance satisfaction. Materials and Methods: In this cross-sectional study, 46 patients with humerus fractures were recruited and their ability to do daily tasks, presence of degenerative changes, stability of elbow joint, and range of motion was evaluated. For assessment of response to surgery, Mayo score was used. Results: Among 46 patients, 45 (97.8% of them had joint stability. Evaluation of postsurgical complications showed that six subjects (13% had no complications, but superficial infection was observed in 12 (26.1% subjects. Neuromuscular disorders in ulnar nerve were present in 11 subjects (23.9%, recurrent articular bursitis of elbow joint in 6 subjects (13%, stiffness of elbow joint in 29 subjects (63%, nonunion of fracture in 3 subjects (6.5%, and myositis ossification in 4 (8.7% subjects. Furthermore, 18 (39.1% patients presented with more than one (2–4 complications. Conclusion: Open reduction and internal fixation surgery with dual plating is the method of choice for treatment of Type C distal humeral fractures. Evaluation of long-term outcomes of this surgery could be done via several different questionnaires as many studies suggest. This study demonstrated that the outcomes of this surgery in Isfahan, Iran, have been noticeably inferior compared to results of the studies in other parts of the world.

  4. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  5. Linear intra-bone geometry dependencies of the radius: Radius length determination by maximum distal width

    International Nuclear Information System (INIS)

    Baumbach, S.F.; Krusche-Mandl, I.; Huf, W.; Mall, G.; Fialka, C.

    2012-01-01

    Purpose: The aim of the study was to investigate possible linear intra-bone geometry dependencies by determining the relation between the maximum radius length and maximum distal width in two independent populations and test for possible gender or age effects. A strong correlation can help develop more representative fracture models and osteosynthetic devices as well as aid gender and height estimation in anthropologic/forensic cases. Methods: First, maximum radius length and distal width of 100 consecutive patients, aged 20–70 years, were digitally measured on standard lower arm radiographs by two independent investigators. Second, the same measurements were performed ex vivo on a second cohort, 135 isolated, formalin fixed radii. Standard descriptive statistics as well as correlations were calculated and possible gender age influences tested for both populations separately. Results: The radiographic dataset resulted in a correlation of radius length and width of r = 0.753 (adj. R 2 = 0.563, p 2 = 0.592) and side no influence on the correlation. Radius length–width correlation for the isolated radii was r = 0.621 (adj. R 2 = 0.381, p 2 = 0.598). Conclusion: A relatively strong radius length–distal width correlation was found in two different populations, indicating that linear body proportions might not only apply to body height and axial length measurements of long bones but also to proportional dependency of bone shapes in general.

  6. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    Science.gov (United States)

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  7. A PROSPECTIVE STUDY ON FUNCTIONAL OUTCOME OF HUMERUS SHAFT FRACTURES TREATED WITH OPEN REDUCTION AND INTERNAL FIXATION WITH DYNAMIC COMPRESSION PLATE AND SCREWS

    Directory of Open Access Journals (Sweden)

    Vidyadhar S. Donimath

    2017-12-01

    Full Text Available BACKGROUND Fracture of the humerus shaft accounts to 3% to 5% of all fractures. Majority of the fractures are unstable due to distraction force of the gravity in the upper limb and strong muscle contraction leading to displacement. Internal fixation and early mobilisation is more stressed on than splinting and prolonged immobilisation to allow earlier mobilisation and rapid return to work. The aim of the study was to study the union rates and the functional outcome and complications associated with shaft humerus fractures in KIMS Hospital. MATERIALS AND METHODS A prospective study which was carried out from October 2015 to September 2017 in Karnataka Institute of Medical Sciences, Hubballi, Karnataka State, India. In this study period, 25 cases of fracture shaft of the humerus were treated by open reduction and internal fixation using DCP. Skeletally mature patients with fresh humerus diaphysis fractures were included in the study. Pathological fractures and Tscherne grade 2 and above, Gustilo Anderson type2 and above were excluded from the study. RESULTS In our series of 25 cases, there were 21 men and 4 women with average age of 42.5 years. Sixteen (64% cases were due to RTA and with predominance of right side. Transverse fractures were most common that is 15 (60% patients. Eleven (31% cases were having associated injuries. 92% of the fractures united with good to excellent outcome. There were 2 (8% cases of non-union due to infection and comminution. CONCLUSION Open reduction and internal fixation with dynamic compression plate is still the standard treatment of choice for fracture shaft of humerus achieving excellent to good functional outcome.

  8. Ablation of musculoskeletal metastases: pain palliation, fracture risk reduction, and oligometastatic disease.

    Science.gov (United States)

    Kurup, Anil Nicholas; Callstrom, Matthew R

    2013-12-01

    Thermal ablation is an effective, minimally invasive alternative to conventional therapies in the palliation of painful musculoskeletal metastases and an emerging approach to obtain local tumor control in the setting of limited metastatic disease. Various thermal ablation technologies have been applied to bone and soft tissue tumors and may be used in combination with percutaneous cement instillation for skeletal lesions with or at risk for pathologic fracture. This article reviews current practices of percutaneous ablation of musculoskeletal metastases with an emphasis on radiofrequency ablation and cryoablation of painful skeletal metastases. © 2013 Elsevier Inc. All rights reserved.

  9. Simulation Of Enhanced Reductive Dechlorination For Remediation Of Tce In A Fractured Clay System: A New Model Approach And Application To Field Site

    DEFF Research Database (Denmark)

    Manoli, Gabriele; Chambon, Julie Claire Claudia; Christiansen, Camilla Maymann

    2010-01-01

    with interspersed sand lenses and stringers. The transport model couples diffusion dominated transport in the clay matrix, with advective‐dispersive transport in the fractures and higher permeability sand lenses. The reactive model calculates sequential reductive dechlorination of TCE (trichloroethylene) to its...... a contamination of trichloroethylene located in a fractured clay till. The site is simulated using the model developed. Fracture geometry, site parameters and degradation rates are based on observations from the site and lab studies. The risk for drinking water is assessed and cleanup times are simulated using...

  10. Transoral open reduction and fixation of mandibular condylar base and neck fractures in children and young teenagers--a beneficial treatment option?

    Science.gov (United States)

    Schiel, Sebastian; Mayer, Peter; Probst, Florian; Otto, Sven; Cornelius, Carl-Peter

    2013-07-01

    To evaluate the possible benefits of open surgery, endoscopically assisted reduction and fixation using a transoral route was used in a selected series of pediatric patients with displaced condylar base and neck fractures. A cohort of 6 patients (1 male and 5 female; age range, 7 to 15 yr; mean, 13.4 yr) with displaced condylar base and neck fractures (n = 9) were included. Inclusion criteria were age younger than 16 years, fracture of the condylar base or neck, and displacement of the fracture by at least 45°. Fractures were classified using conventional radiography, cone-beam computed tomography, or computed tomography. Patients underwent transoral endoscopically assisted open reduction and fixation using miniplate osteosynthesis. Postoperatively, patients were followed clinically and radiographically for 18 months. Complete follow-up varied from 18 to 35 months (median, 24.5 months). All patients showed normal occlusion and pain-free unrestricted function of the temporomandibular joint at 3, 6, 12, and 18 months postoperatively. There were no signs of incomplete remodeling or deformation of the condyles. Transoral endoscopically assisted surgical treatment of severely displaced condylar base and neck fractures in children and young teenagers offers a reliable solution to preclude the sequelae of closed treatment, such as altered morphology and functional disturbances, eliminates visible scars, and lowers the risk of facial nerve damage compared with open reduction using an extraoral approach. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  11. Pitfalls associated with open reduction and internal fixation of fractured ribs.

    Science.gov (United States)

    Sarani, Babak; Schulte, Leah; Diaz, Jose J

    2015-12-01

    Rib fracture is exceedingly common and remains a leading cause of death in patients with chest injury. Probability of death increases by 19% with each broken rib, and the probability of death increases further with age. Treatment is centered on pain control and early mobilization to provide adequate pulmonary hygiene. Multimodality interventions, such as incentive spirometry, postural changes, and coughing, are pivotal in minimizing the risk of pneumonia and death. Recently, many studies have found mortality benefit to operation fixation (ORIF) of ribs in select patients. However, this procedure remains underutilized partly due to lack of familiarity with its technique and pitfalls by trauma surgeons, in particular. Whereas there are publications on operative technique, there are no studies describing pitfalls associated with this procedure. The purpose of this paper is to describe pitfalls on the technical aspects of ORIF of the ribs based on the medical literature where possible and based on our experience in instances where peer reviewed evidence is lacking. The paper is not meant to serve as a protocol for managing rib fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Do Open Reduction and Internal Fixation With Articular Disc Anatomical Reduction and Rigid Anchorage Manifest a Promising Prospect in the Treatment of Intracapsular Fractures?

    Science.gov (United States)

    Cai, Bo-Lei; Ren, Rong; Yu, Hong-Bo; Liu, Peng-Chao; Shen, Steve G F; Shi, Jun

    2018-05-01

    In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Clinical study of emergency treatment and selective closed reduction for the treatment of supracondylar humerus fracture in children

    Directory of Open Access Journals (Sweden)

    Wei Zhong

    2016-11-01

    Full Text Available Objective: To study the effect of emergency treatment, selective closed reduction combined with percutaneous Kirschner wire fixation on the treatment of Gartland type-II and type-III supracondylar humerus fracture. Methods: Children who sustained the Gartland type-II and type-III supracondylar fractures of humerus treated with selective closed reduction combined with percutaneous Kirschner wire fixation in our hospital from May 2012 to August 2015 were analyzed retrospectively. They were divided into group A (emergency operation group and group B (selective operation group according to different operation timing. Perioperative situation, blood biochemical parameters, swelling degree and elbow joint function of affected limb were compared between two groups. Results: Operation time for patients of group A was significantly shorter than that of group B [(17.19 ± 2.85 vs. (21.43 ± 3.91 min], and frequency of fluoroscopy during operation of group A was obviously less than that of group B [(6.03 ± 0.95 vs. (7.61 ± 0.92 times]. Swelling index of affected limb in group A at 3 days, 5 days and 7 days after injury was all significantly lower than that in group B [(1.20 ± 0.17 vs. (1.38 ± 0.14, (1.13 ± 0.13 vs. (1.30 ± 0.18, (1.02 ± 0.15 vs. (1.22 ± 0.15]. Hospital for special surgery score at 1 week, 2 weeks, 3 and 4 weeks after removing Kirschner wire had no significant difference between group A and B (88.75 ± 10.18 vs. (89.14 ± 10.52, (94.22 ± 10.85 vs. (93.85 ± 11.08, (95.52 ± 11.27 vs. (95.92 ± 12.19, (95.43 ± 10.96 vs. (96.02 ± 11.38. Contents of serum alanine transaminase, aspertate aminotransferase, total protein, albumin and C-reactive protein in perioperative period had no obvious difference between patients in group A and B. Conclusions: Emergency closed reduction combined with percutaneous Kirschner wire fixation for Gartland type-II and type-III supracondylar humerus fracture in children has less trauma, low swelling degree

  14. Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

    Science.gov (United States)

    Ahrens, Philipp; Sandmann, Gunther; Bauer, Jan; König, Benjamin; Martetschläger, Frank; Müller, Dirk; Siebenlist, Sebastian; Kirchhoff, Chlodwig; Neumaier, Markus; Biberthaler, Peter; Stöckle, Ulrich; Freude, Thomas

    2012-09-01

    Fractures of the tibial plateau are among the most severe injuries of the knee joint and lead to advanced gonarthrosis if the reduction does not restore perfect joint congruency. Many different reduction techniques focusing on open surgical procedures have been described in the past. In this context we would like to introduce a novel technique which was first tested in a cadaver setup and has undergone its successful first clinical application. Since kyphoplasty demonstrated effective ways of anatomical correction in spine fractures, we adapted the inflatable instruments and used the balloon technique to reduce depressed fragments of the tibial plateau. The technique enabled us to restore a congruent cartilage surface and bone reduction. In this technique we see a useful new method to reduce depressed fractures of the tibial plateau with the advantages of low collateral damage as it is known from minimally invasive procedures.

  15. OC30 - Fracture reduction with nitrous oxide at the children's emergency department shortens the length of stay and reduces the use of full anaesthesia in the operating department.

    Science.gov (United States)

    Lang, Sigrid; Wentzel, Anna-Pia; Ekstrom, Malin

    2016-05-09

    Theme: Accreditation and quality improvement. Dislocated fractures are common in the children's emergency department (ER). All forms of fracture reduction are very painful requiring nitrous oxide. The purpose is to shorten the length of stay in the hospital as well as sustain a high quality of care. All nurses received theoretical and practical training in the use of nitrous oxide. Evaluations with the families were made by telephone. A total of 40 enclosed fracture reductions were made at the ER, leading to a reduction of 33 patients in the operating department and the length of stay was shortened - this compared to the same time in 2014. No adverse event was reported and no patient felt any increase in pain during the treatment. All patients would repeat the procedure if necessary. The treatment has reduced the length of stay in the hospital without affecting the other patients in the ER or the quality of care.

  16. Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    Science.gov (United States)

    Kern, Andrew M; Anderson, Donald D

    2015-09-18

    Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promising agreement with PTOA development was seen, the inherent complexities of contact FEA limited the numbers of subjects that could be analyzed. Discrete element analysis (DEA) is a simplified methodology for contact stress computation, which idealizes contact surfaces as a bed of independent linear springs. In this study, DEA was explored as an expedited alternative to FEA contact stress exposure computation. DEA was compared to FEA using results from a previously completed validation study of two cadaveric human ankles, as well as a previous study of post-operative contact stress exposure in 11 patients with tibial plafond fracture. DEA-computed maximum contact stresses were within 19% of those experimentally measured, with 90% of the contact area having computed contact stress values within 1MPa of those measured. In the 11 fractured ankles, maximum contact stress and contact area differences between DEA and FEA were 0.85 ± 0.64 MPa and 22.5 ± 11.5mm(2). As a predictive measure for PTOA development, both DEA and FEA had 100% concordance with presence of OA (KL grade ≥ 2) and >95% concordance with KL grade at 2 years. These results support DEA as a reasonable alternative to FEA for computing contact stress exposures following surgical reduction of a tibial plafond fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    International Nuclear Information System (INIS)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E.

    1992-01-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author)

  18. The computed tomographic evaluation of patellofemoral joint in patellar fractures treated with open reduction and internal fixation

    Energy Technology Data Exchange (ETDEWEB)

    Benli, I.T.; Akalin, S.; Mumcu, E.F.; Citak, M.; Kilic, M.; Pasaoglu, E. (Ankara Social Security Hospital (Turkey))

    1992-08-01

    In this study, we examined 97 patella fractures in which open reduction and internal fixation had been performed at the 1st Orthopaedics and Trauma Clinic of Social Security Ankara Hospital between January 1983 and December 1988. After 24 to 96 months, on an average of 48.4 months follow-up period, the cases were evaluated clinically for knee function complaints and by CT and roentgenography for patellofemoral articulation. In 11 of the patients (11.5%) there was patellar displacement, 2 of the patients had patellar tilt (2.1%) and in 14 patients (14.5%) there was malalignment in which 1 patient (1.1%) had both patellar tilt and displacement. This data was obtained by measuring femoral trochlear angle (FTA) and patellar tilt angle (PTA) by CT at various degrees of knee flexion. Thirty three patients (34%) had slight and 19 patients (19.6%) had severe degenerative changes in the patellofemoral articulation. It is found that there is close relation between the variability of the pain complaints of the patients and the type of the fracture and the time of management and the postoperative rehabilitation. (author).

  19. The application of closed reduction internal fixation and iliac bone block grafting in the treatment of acute displaced femoral neck fractures.

    Directory of Open Access Journals (Sweden)

    Zhiyong Li

    Full Text Available OBJECTIVE: This study aimed to evaluate the preliminary clinical and radiographic outcomes of acute displaced femoral neck fracture treated by closed reduction and internal fixation (CRIF with free iliac bone block grafting with comparison to a routine protocol of CRIF without bone grafting. METHODS: From December 2008 to February 2010, 220 adult patients with acute displaced femoral neck fractures were enrolled in this study. In study group, there were 124 patients (57 males, 67 females with a mean age of 44.8 years (range, 20-64 years. There were 70 transcervical fractures and 54 subcapital fractures. The patients were treated by CRIF and free iliac bone block grafting. The control group consisted of 96 adult patients (46 males, 50 females with a mean age of 46.3 years (range, 23-64 years. There were 61 transcervical fractures and 35 subcapital fractures. The patients in control group were treated by CRIF without bone grafting. RESULTS: In study group, 112 patients were followed up for an average of 27.4 months (range, 24-34 months. All fractures healed within 5 months. However, 10 patients presented AVN of the femoral heads. The mean Harris score was 88.6 (range, 41-100. In control group, 68 patients were followed up for an average of 31.2 months (range, 24-42 months. The rates of AVN of the femoral head and fracture nonunion in control group were 26.5% (18/68 and 16.2% (11/68, respectively, significantly higher than those in study group (both P<0.05. The mean Harris score in control group was 83.8 (41-100, significantly lower than that in study group (P<0.05. CONCLUSION: Acute displaced femoral neck fractures can be treated by CRIF and free iliac bone block grafting in a minimally invasive manner. This technique can guarantee uneventful fracture healing and significantly reduce the rate of femoral head osteonecrosis.

  20. Complications and functional outcome after internal fixation of dorsally displaced distal radial fractures

    DEFF Research Database (Denmark)

    Bove, Jeppe; Viberg, Bjarke; Wied Greisen, Pernille

    Background: Recently there has been an increasing interest in open reduction and internal fixation of distal radius fractures. Even so further studies are still needed. Purpose: To document the functional outcome and identify complica- tions among patients treated with a volar locking plate (DVR...

  1. [Calcaneal fractures treated by open reduction and internal fixation with a locking compression plate (LCP). A prospective study. part I: basic analysis of the group].

    Science.gov (United States)

    Svatoš, F; Bartoška, R; Skála-Rosenbaum, J; Douša, P; Pacovský, V; Krbec, M

    2011-01-01

    In a prospective study of patients with calcaneal fractures treated by open reduction from an extensile lateral approach and LCP osteosynthesis, the authors evaluated the basic epidemiological data, mechanism of injury, type of fracture, essential data on surgery, days of hospital stay and the number of complications. In the period from September 1, 2006 to July 31, 2010, a total of 230 patients with 243 calcaneal fractures were treated. The fractures were classified as either open or closed and according to the Essex-Lopresti system. Of the total number of patients, 135 (55.6 % of all fractures) were indicated for conservative treatment and 108 (44.4% of all fractures) for surgical intervention. Indications for surgery based on the generally accepted criteria enabled us to select 77 patients with 82 fractures (33.7 % of all fractures) for treatment by the method of open reduction and LCP osteosynthesis. These patients constituted the group evaluated here. The other patients were treated using other techniques (21 fractures, i.e., 8.6 % of all fractures, by the Stehlík-Štulík transfixation method and further five [2.1 %] by screw osteosynthesis). Six surgeons were involved in the treatment of this group. For the diagnosis of fractures, plain radiographs in lateral and axial projection and axial and coronal CT images were used. All fractures were treated after subsidence of oedema by the method of open reduction and LCP fixation from an extensile lateral approach, with the use of a tourniquet. The follow-up period for the evaluation of functional outcome and bone union was 3 to 48 months. Fifty patients were followed up for over one year. The group evaluated comprised 58 men (75.3 %) with 63 fractures (76.8 %) and 19 women (24.7 %) with 19 fractures (23.2 %). The average age of the group was 42 years, with 41 years (range, 22-61 years) in men and 47 years (range, 30-70 years) in women. The most frequent cause of injury was a fall from a height below 1 metre and

  2. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material.

    Science.gov (United States)

    Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Takahashi, Kazuhisa

    2014-11-01

    Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.

  3. A new method for classifying distal radius fracture: the IDEAL classification Um novo método de classificação para as fraturas da extremidade distal do rádio – a classificação IDEAL

    Directory of Open Access Journals (Sweden)

    João Carlos Belloti

    2013-01-01

    Full Text Available OBJECTIVES: To describe the new IDEAL method from classifying distal radius fractures. METHODS: IDEAL classification system is based on the most important literature evidences about clinical and radiographic characteristics that influence in the treatment and prognosis for patients that suffered from a distal radius fractures. In this method, we classify the fracture in patients first consultation, in which we collect demographical (age and trauma energy and radiographic characteristics ( fracture deviation, articular fracture, and associated lesions. For each feature a score is attributed for grouping purposes. Group I - Stable fractures, good prognosis; Group II - potentially unstable fractures, commonly treated by surgical methods. Prognosis depends on surgeons' success after method choice. Group III - complex and instable fractures, poor outcome is expected. CONCLUSION: IDEAL classification staging rationale was presented, which is based on the best available evidence. The evidence of its scientific plausibility will be settled with the assessment of the classification reliability and its capacity to aid in therapeutical decisions and as a tool to predict prognosis. Further studies are under development to support these properties. OBJETIVOS: Descrição do método de Classificação IDEAL - para as fraturas da extremidade distal do rádio. MÉTODOS: O sistema de classificação IDEAL fundamenta-se nas principais evidências da literatura sobre fatores clínicos e radiográficos que influenciam o tratamento e prognóstico das fraturas do rádio distal. Classificamos as fraturas no atendimento inicial do paciente mediante a verificação de dois dados epidemiológicos e três dados radiográficos: Idade do paciente, energia do trauma, desvio dos fragmentos, incongruência articular e lesões associadas. RESULTADOS: Conforme a pontuação obtida, agrupamos os casos em três grupos: Grupo I - fraturas estáveis com bom prognóstico, Grupo II

  4. Bimalleolar ankle fracture with proximal fibular fracture

    NARCIS (Netherlands)

    Colenbrander, R. J.; Struijs, P. A. A.; Ultee, J. M.

    2005-01-01

    A 56-year-old female patient suffered a bimalleolar ankle fracture with an additional proximal fibular fracture. This is an unusual fracture type, seldom reported in literature. It was operatively treated by open reduction and internal fixation of the lateral malleolar fracture. The proximal fibular

  5. A Novel Minimally Invasive Reduction Technique by Balloon and Distractor for Intra-Articular Calcaneal Fractures: A Report of 2 Cases

    Directory of Open Access Journals (Sweden)

    M. Prod’homme

    2018-01-01

    Full Text Available Treatment of displaced intra-articular fractures of the calcaneus remains a challenge for the orthopaedic surgeon. Conservative therapy is known to produce functional impairment. Surgical approach is plagued by soft-tissue complications and insufficient fracture reduction. We describe a minimally invasive technique that will hopefully improve these issues. We want to present our first experience through two cases. The first was a 46-year-old man who presented with a Sanders type IIBC calcaneal fracture, and the second was a 86-year-old woman with a type IIIBC calcaneal fracture. We introduced 2 Schanz screws in the talus and the calcaneus. After distraction, we introduced an inflatable balloon inside the calcaneus. By inflating the balloon, the articular surface was reduced by lifting it up. Then bone cement was injected in order to maintain the reduction. Additional screw fixation was used in the young patient. Postoperative imaging showed good congruence of the subtalar joint without leakage of cement, for the two cases. After 2 months, the patients had no pain and were without soft-tissue complications. We advocate this technique to perform a minimally invasive reduction and fixation of intra-articular calcaneal fractures because it preserves soft-tissues and provides good clinical results with early weight-bearing.

  6. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  7. Capturing the complex behavior of hydraulic fracture stimulation through multi-physics modeling, field-based constraints, and model reduction

    Science.gov (United States)

    Johnson, S.; Chiaramonte, L.; Cruz, L.; Izadi, G.

    2016-12-01

    Advances in the accuracy and fidelity of numerical methods have significantly improved our understanding of coupled processes in unconventional reservoirs. However, such multi-physics models are typically characterized by many parameters and require exceptional computational resources to evaluate systems of practical importance, making these models difficult to use for field analyses or uncertainty quantification. One approach to remove these limitations is through targeted complexity reduction and field data constrained parameterization. For the latter, a variety of field data streams may be available to engineers and asset teams, including micro-seismicity from proximate sites, well logs, and 3D surveys, which can constrain possible states of the reservoir as well as the distributions of parameters. We describe one such workflow, using the Argos multi-physics code and requisite geomechanical analysis to parameterize the underlying models. We illustrate with a field study involving a constraint analysis of various field data and details of the numerical optimizations and model reduction to demonstrate how complex models can be applied to operation design in hydraulic fracturing operations, including selection of controllable completion and fluid injection design properties. The implication of this work is that numerical methods are mature and computationally tractable enough to enable complex engineering analysis and deterministic field estimates and to advance research into stochastic analyses for uncertainty quantification and value of information applications.

  8. On the proton radius problem

    OpenAIRE

    Giannini, M. M.; Santopinto, E.

    2013-01-01

    The recent values of the proton charge radius obtained by means of muonic-hydrogen laser spectroscopy are about $4\\%$ different from the electron scattering data. It has been suggested that the proton radius is actually measured in different frames and that, starting from a non relativistic quark model calculation, the Lorentz transformation of the form factors accounts properly for the discepancy. We shall show that the relation between the charge radii measured in different frames can be de...

  9. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].

    Science.gov (United States)

    Zeman, P; Zeman, J; Matejka, J; Koudela, K

    2008-12-01

    To report on the surgical treatment of intra-articular calcaneal fractures by open reduction and internal fixation with a calcaneal locking compression plate (LCP) from an extended lateral approach, and to retrospectively analyze the mid-term results in a group of patients treated by this technique. In the period from August 2005 till March 2007, a total of 49 patients with 61 calcaneal fractures were treated. Of these, 11 (18 %) were treated conservatively. Reduction combined with Kirschner-wire fixation was used in four fractures (6.6 %). Open reduction with internal calcaneal LCP fixation (ORIF- calcaneal LCP) from an extended lateral approach was carried out to treat 46 fractures (75.4 %) in 38 patients. The group evaluated here comprised 29 patients with 33 calcaneal fractures treated by ORIF-calcaneal LCP at a follow-up longer than 6 months. The fractures were classified on the basis of computer tomography (CT) findings as Sanders types I to IV. The group had two woman (6.9 %) and 27 men (93.1 %) with an average age of 34.2 years (range, 19-55 years). In 11 fractures (33.3 %), the primary treatment included filling a central cancellous bone defect area. Calcium phosphate bone substitute material (resorbable ChronOS) was used in nine cases (27.3 %), a self-solidifying hydroxyapatite implant was injected in two (6.1 %) cases (X3 Wright and Norian SRS, respectively), and a bone allograft was implanted in one case (3 %). Indicated for surgery were patients with an intra-articular calcaneal fracture, Sanders type II or type III, with articular surface displacement by more than 1 mm. Contraindications included age over sixty years, poor cooperation, smoking habits, peripheral vascular disease or skin infection. Surgery was performed only after oedema had resolved. The aim of our treatment was to achieve anatomical reconstruction of all articular surfaces, to restore the height, length, width and axis of the heel bone, to carry out primary stable osteosynthesis, and

  10. Effectiveness of Dual-Maneuver Using K-Wire and Dingman Elevator for the Reduction of Unstable Zygomatic Arch Fracture.

    Science.gov (United States)

    Yoon, Hyungwoo; Kim, Jiye; Chung, Seum; Chung, Yoon-Kyu

    2014-08-01

    The zygoma is the most prominent portion of the face. Almost all simple zygomatic arch fractures are treated in a closed fashion with a Dingman elevator. However, the open approach should be considered for unstable zygomatic arch fractures. The coronal approach for a zygomatic arch fracture has complications. In this study, we introduce our method to reduce a special type of unstable zygomatic fracture. We retrospectively reviewed zygomatic arch view and facial bone computed tomography scans of 424 patients who visited the Wonju Severance Christian Hospital from 2007 to 2010 with zygomaticomaxillary fractures, among whom 15 patients met the inclusion criteria. We used a Dingman elevator and K-wire simultaneously to manage this type of zygomatic arch fracture. Simple medial rotation force usually collapses the posterior fractured segment, and the fracture becomes unstable. Thus, the posterior fracture segment must be concurrently elevated with a Dingman elevator through Keen's approach with rotation force applied through the K-wire. All fractures were reduced without any instability using this method. We were able to reduce unstable and difficult zygomatic arch fractures without an open incision or any external fixation device.

  11. Mandible Fractures.

    Science.gov (United States)

    Pickrell, Brent B; Serebrakian, Arman T; Maricevich, Renata S

    2017-05-01

    Mandible fractures account for a significant portion of maxillofacial injuries and the evaluation, diagnosis, and management of these fractures remain challenging despite improved imaging technology and fixation techniques. Understanding appropriate surgical management can prevent complications such as malocclusion, pain, and revision procedures. Depending on the type and location of the fractures, various open and closed surgical reduction techniques can be utilized. In this article, the authors review the diagnostic evaluation, treatment options, and common complications of mandible fractures. Special considerations are described for pediatric and atrophic mandibles.

  12. Facial nerve injuries associated with the retromandibular transparotid approach for reduction and fixation of mandibular condyle fractures.

    Science.gov (United States)

    Shi, Dan; Patil, Pavan Manohar; Gupta, Ritika

    2015-04-01

    To document facial nerve (FN) injuries after surgical treatment of mandibular condylar fractures using the retromandibular transparotid approach and to identify risk factors associated with these injuries. A retrospective study of patients surgically treated for mandibular condylar fractures using the retromandibular transparotid approach over seven years was conducted. The primary study variable was the postoperative change in FN function after fracture fixation. Risk factors were categorized as demographic, anatomic, experience of the operator, fracture displacement/dislocation and number of miniplates placed at the fracture site. Appropriate statistics were computed. Ninety patients with 102 fractures were analysed. Thirty two fractures (31%) were located in the condylar neck and 70 fractures (69%) were subcondylar (located below the sigmoid notch). The condylar segment was undisplaced in twelve cases (12%), displaced medially in thirty five (34%), laterally displaced in thirty (29%) and dislocated in 25 (24.5%). In 18 fractures (18%), postoperative examination revealed various degrees of damage to the FN. All nerve injuries recovered completely in 8-24 weeks. In a multivariate model, condylar neck fractures, fracture dislocation and operator inexperience were associated with a statistically significant risk of postoperative deterioration of FN function (P ≤ 0.05). The majority of facial nerve injuries after surgical treatment of condylar fractures by the retromandibular transparotid approach are transient in nature. Condylar neck fractures, fracture dislocation and operator inexperience were associated with an increased risk for FN injury. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Non union of the neck of radius: a case report and review of the ...

    African Journals Online (AJOL)

    Fractures of the neck of radius are frequent in trauma. They happen without being noticed at the moment of injury of the elbow or in the context of polytrauma. A case of non union of the radius neck occurring in a young person due to ignorance, during first consultation has been reported by the authors. They insist on the ...

  14. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    Science.gov (United States)

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  15. Negative pressure pulmonary edema after nasal fracture reduction in an obese female patient: a case report

    Directory of Open Access Journals (Sweden)

    Choi EK

    2015-08-01

    Full Text Available Eunkyung Choi,1 Junggu Yi,1 Younghoon Jeon,2 1Department of Anesthesiology and Pain Medicine, School of Medicine, Kyungpook National University, Daegu, Republic of Korea; 2Department of Anesthesiology and Pain Medicine, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea Abstract: Postoperative negative pressure pulmonary edema (NPPE is a rare, but well-known life-threatening complication of acute upper airway obstruction (UAO which develops after general anesthesia. The pronounced inspiratory efforts following UAO lead to excessive negative inspiratory pressure, which may cause acute pulmonary edema. Early recognition and prompt treatment of NPPE is necessary to prevent patient morbidity and mortality. In addition, the physician should carefully manage the patient who has risk factors of UAO to prevent this situation. We experienced a case of NPPE following laryngospasm after tracheal extubation in an obese patient who underwent open reduction of orbital wall and nasal bone surgery. Keywords: airway obstruction, negative pressure pulmonary edema, laryngospasm, nasal surgery, obese

  16. [Treatment of open tile type C pelvic fractures by open reduction and internal fixation through anterior and posterior approaches at early stage].

    Science.gov (United States)

    Li, Baichuan

    2014-05-01

    To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.

  17. High incidence of osteochondral lesions after open reduction and internal fixation of displaced ankle fractures: Medium-term follow-up of 100 cases.

    Science.gov (United States)

    Regier, Marc; Petersen, Jan Philipp; Hamurcu, Ahmet; Vettorazzi, Eik; Behzadi, Cyrus; Hoffmann, Michael; Großterlinden, Lars G; Fensky, Florian; Klatte, Till Orla; Weiser, Lukas; Rueger, Johannes M; Spiro, Alexander S

    2016-03-01

    The incidence of osteochondral lesions (OCLs) in association with displaced ankle fractures has only been examined in two previous studies. In both studies magnetic resonance imaging (MRI) was performed prior to open reduction and internal fixation (ORIF). Because MRI may overdiagnose or overestimate the extent of OCLs in an acute trauma setting the aim of this study was to determine the incidence of OCLs after ORIF of displaced ankle fractures using MRI at medium-term follow-up, and to analyse if the severity of fracture or the clinical outcome correlates with the incidence of OCLs. Following institutional review board approval a total of 100 patients (mean age, 41.3 years; range, 17.9-64.3 years) with a displaced ankle fracture who had undergone ORIF according to the AO principles were included in this study. The American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score was used to quantify the clinical outcome and MR images were evaluated for OCLs of the talus and distal tibia after a mean of 34.5 months (range, 17.5-54.1 months). OCLs were found in 40.4% of the patients. Logistic regression revealed a significant correlation between the severity of fracture and the incidence of OCLs. Patients with a trimalleolar fracture (p=0.04) or an ankle fracture dislocation (p=0.003) had a significantly higher risk for developing an OCL compared to those with a type B fracture. Logistic regression also demonstrated a significant correlation between the clinical outcome (AOFAS score) and the incidence of OCLs (p=0.01). The risk for developing an OCL increases up to 5.6% when the AOFAS score decreases by one point. OCLs were frequently found in association with acute ankle fractures at medium-term follow-up, and the severity of fracture was associated with an increased number of OCLs. Considering the disadvantages of MRI including the high cost and limited availability, the results of this study may help to explain why anatomic surgical realignment of displaced

  18. Effect of decreased hot-rolling reduction treatment on fracture toughness of low-alloy structural steels

    Science.gov (United States)

    Tomita, Yoshiyuki

    1990-09-01

    Commercial low-alloy structural steels, 0.45 pct C (AISI 1045 grade), 0.40 pct C-Cr-Mo (AISI 4140 grade), and 0.40 pct C-Ni-Cr-Mo (AISI 4340 grade), have been studied to determine the effect of the decreased hot-rolling reduction treatment (DHRRT) from 98 to 80 pct on fracture toughness of quenched and highly tempered low-alloy structural steels. The significant conclusions are as follows: (1) the sulfide inclusions were modified through the DHRRT from a stringer (mean aspect ratio: 16.5 to 17.6) to an ellipse (mean aspect ratio: 3.8 to 4.5), independent of the steels studied; (2) the DHRRT significantly improved J Ic in the long-transverse and shorttransverse orientations, independent of the steels studied; and (3) the shelf energy in the Charpy V-notch impact test is also greatly improved by the DHRRT, independent of testing orientation and steels studied; however, (4) the ductile-to-brittle transition temperature was only slightly affected by the DHRRT. The beneficial effect on the J Ic is briefly discussed in terms of a crack extension model involving the formation of voids at the inclusion sites and their growth and eventual linking up through the rupture of the intervening ligaments by local shear.

  19. Closed reduction and fluoroscopic assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats

    OpenAIRE

    Boekhout-Ta, Christina L; Kim, Stanley E; Corss, Alan R; Pozzi, Antonio; Evans, Richard

    2017-01-01

    OBJECTIVE: To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. STUDY DESIGN: Retrospective study. ANIMALS: Client-owned dogs (n = 37) and cats (n = 4). MATERIALS AND METHODS: Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classi...

  20. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    ; they will show a sagittally oriented fracture line at the roof of the acetabulum on axial CT. Lastly, wall fractures should be evaluated with axial CT images. This is because wall fractures have an obliquely oriented fracture line on axial CT images at the roof of the acetabulum, as opposed to the coronal and sagittal fracture lines described with column and transverse fractures, respectively.2 Fractures are organized using the Letournel Classification based on whether the fracture site lies in the anterior or posterior walls and columns of bone. After diagnosis, early surgical intervention is critical in achieving good results.3 The majority of acetabular fractures are repaired by open reduction and internal fixation. Patients with significant osteopenia or communition benefit most from total hip arthroplasty. However, due to the complex nature of these fractures, there is potential for poor outcome regardless of the injury pattern due to contributing factors such as imperfect reduction, osteochondral defects in the acetabulum or femoral head, osteoarthritis, avascular necrosis of the femoral head, sciatic nerve injury and infection.4

  1. Study of the X-Ray Diagnosis of Unstable Pelvic Fracture Displacements in Three-Dimensional Space and its Application in Closed Reduction.

    Science.gov (United States)

    Shi, Chengdi; Cai, Leyi; Hu, Wei; Sun, Junying

    2017-09-19

    ABSTRACTS Objective: To study the method of X-ray diagnosis of unstable pelvic fractures displaced in three-dimensional (3D) space and its clinical application in closed reduction. Five models of hemipelvic displacement were made in an adult pelvic specimen. Anteroposterior radiographs of the pelvis were analyzed in PACS. The method of X-ray diagnosis was applied in closed reductions. From February 2012 to June 2016, 23 patients (15 men, 8 women; mean age, 43.4 years) with unstable pelvic fractures were included. All patients were treated by closed reduction and percutaneous cannulate screw fixation of the pelvic ring. According to Tile's classification, the patients were classified into type B1 in 7 cases, B2 in 3, B3 in 3, C1 in 5, C2 in 3, and C3 in 2. The operation time and intraoperative blood loss were recorded. Postoperative images were evaluated by Matta radiographic standards. Five models of displacement were made successfully. The X-ray features of the models were analyzed. For clinical patients, the average operation time was 44.8 min (range, 20-90 min) and the average intraoperative blood loss was 35.7 (range, 20-100) mL. According to the Matta standards, 7 cases were excellent, 12 cases were good, and 4 were fair. The displacements in 3D space of unstable pelvic fractures can be diagnosed rapidly by X-ray analysis to guide closed reduction, with a satisfactory clinical outcome.

  2. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Paediatric post-traumatic cortical defects of the distal radius

    International Nuclear Information System (INIS)

    Roach, Richard T.; Summers, Bruce N.; Cassar-Pullicino, Victor

    2002-01-01

    Paediatric post-traumatic cortical defects, although rare, are predominately seen affecting the distal radius following a greenstick or torus fracture. We review the literature and present a further two cases supported by CT and MRI. Images from an acute greenstick fracture are also presented to help understand the pathogenesis. Defects are typically solitary on plain radiographs and are usually noticed late, proximal to the site of compression. They are non-expansile in an otherwise healthy child. CT and MRI may reveal smaller multiple subperiosteal defects. Typical defects require no further management other than reassurance and advice that they may occasionally cause discomfort but resolve with time. (orig.)

  4. Complex tibial plateau fractures treated by hybrid external fixation system: A correlation of followup computed tomography derived quality of reduction with clinical results

    Directory of Open Access Journals (Sweden)

    Konstantinos Kateros

    2018-01-01

    Full Text Available Background: Tibial plateau fractures are common due to high energy injuries. The principles of treatment include respect for the soft tissues, restoring the congruity of the articular surface and reduction of the anatomic alignment of the lower limb to enable early movement of the knee joint. There are various surgical fixation methods that can achieve these principles of treatment. Recognition of the particular fracture pattern is important, as this guides the surgical approach required in order to adequately stabilize the fracture. This study evaluates the results of the combined treatment of external fixator and limited internal fixation along with the advantages using postoperative computed tomography (CT scan after implant removal. Materials and Methods: 55 patients with a mean age of 42 years (range 17–65 years with tibial plateau fracture, were managed in our institution between October 2010 and September 2013., Twenty fractures were classified as Schatzker VI and 35 as Schatzker V. There were 8 open fractures (2 Gustilo Anderson 3A and 6 Gustilo Anderson 2. All fractures were treated with closed reduction and hybrid external fixation (n = 21/38.2% or with minimal open reduction internal fixation and a hybrid system (n = 34/61.8%. After the removal of the fixators, CT-scan was programmed for all the cases, for correlation with the results. At final followup, the American Knee Society Score (AKSS was administered. Results: All patients were evaluated with a minimum of 12 months (range 12–21 months followup. Average time to union was 15.5 weeks (range 13–19 weeks. The postoperative joint congruity as evaluated in the postoperative CT-scan was 5° in 19 cases (35%. Patients with residual joint depression 4.5 mm displayed a 100% chance of getting poor-fair scores both in AKSS knee and AKSS function score. The association of a postoperative mechanical axis within 5° of the contralateral limb and improved knee scores was statistically

  5. Simulation-Based Educational Module Improves Intern and Medical Student Performance of Closed Reduction and Percutaneous Pinning of Pediatric Supracondylar Humeral Fractures.

    Science.gov (United States)

    Butler, Bennet A; Lawton, Cort D; Burgess, Jamie; Balderama, Earvin S; Barsness, Katherine A; Sarwark, John F

    2017-12-06

    Simulation-based education has been integrated into many orthopaedic residency programs to augment traditional teaching models. Here we describe the development and implementation of a combined didactic and simulation-based course for teaching medical students and interns how to properly perform a closed reduction and percutaneous pinning of a pediatric supracondylar humeral fracture. Subjects included in the study were either orthopaedic surgery interns or subinterns at our institution. Subjects all completed a combined didactic and simulation-based course on pediatric supracondylar humeral fractures. The first part of this course was an electronic (e)-learning module that the subjects could complete at home in approximately 40 minutes. The second part of the course was a 20-minute simulation-based skills learning session completed in the simulation center. Subject knowledge of closed reduction and percutaneous pinning of supracondylar humeral fractures was tested using a 30-question, multiple-choice, written test. Surgical skills were tested in the operating room or in a simulated operating room. Subject pre-intervention and post-intervention scores were compared to determine if and how much they had improved. A total of 21 subjects were tested. These subjects significantly improved their scores on both the written, multiple-choice test and skills test after completing the combined didactic and simulation module. Prior to the module, intern and subintern multiple-choice test scores were significantly worse than postgraduate year (PGY)-2 to PGY-5 resident scores (p < 0.01); after completion of the module, there was no significant difference in the multiple-choice test scores. After completing the module, there was no significant difference in skills test scores between interns and PGY-2 to PGY-5 residents. Both tests were validated using the scores obtained from PGY-2 to PGY-5 residents. Our combined didactic and simulation course significantly improved intern and

  6. Ever-changing proton radius?

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovic, Miha [Institut fuer Kernphysik, Johannes-Gutenberg-Universitaet, Mainz (Germany)

    2016-07-01

    The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the presently best value obtained from elastic scattering experiments remains unexplained and represents a burning problem of today's nuclear physics. Therefore, several new experiments are underway, committed to provide new insight into the problem. High-precision electron scattering experiments are in progress at the Jefferson Lab and the Mainz Microtron. As a counterpart to these measurements, a muon-proton scattering experiment is envisioned at the Paul Scherrer Institute. Together with the nuclear scattering experiments, new atomic measurements are underway at the Max Planck Institute in Garching, which aim to further improve also the spectroscopic results on electronic hydrogen. These experiments are complemented by extensive theoretical efforts focused on studying various processes contributing to the atomic Lamb shift measurements that could explain the difference, as well as on pursuing different ways to interpret nuclear form-factor measurements, which could lead to a consistent value of the radius. In this presentation the currently best proton radius measurements are summarized, and the importance of the observed inconsistency between the hydrogen and the muonic-hydrogen data is discussed. Selected new experiments dedicated to remeasuring the radius are described, and the results of the MAMI experiment are presented.

  7. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    Science.gov (United States)

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  9. Antifracture efficacy and reduction of mortality in relation to timing of the first dose of zoledronic acid after hip fracture

    DEFF Research Database (Denmark)

    Eriksen, Erik Fink; Lyles, Kenneth W; Colón-Emeric, Cathleen S

    2009-01-01

    undergone surgical repair of hip fracture. In this analysis, we examined whether timing of the first infusion of zoledronic acid study drug after hip fracture repair influenced the antifracture efficacy and mortality benefit observed in the study. A total of 2127 patients (1065 on active treatment and 1062...... was approximately 6 wk. Posthoc analyses were performed by dividing the study population into 2-wk intervals (calculated from time of first infusion in relation to surgical repair) to examine effects on BMD, fracture, and mortality. Analysis by 2-wk intervals showed a significant total hip BMD response......Annual infusions of zoledronic acid (5 mg) significantly reduced the risk of vertebral, hip, and nonvertebral fractures in a study of postmenopausal women with osteoporosis and significantly reduced clinical fractures and all-cause mortality in another study of women and men who had recently...

  10. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases.

    Science.gov (United States)

    St-Jean, G; Debowes, R M

    1992-04-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.At the time of injury, the calves ranged in age from one day to two months and weighed from 37-102 kg. Two fractures were comminuted and one was transverse. All fractures were closed. After surgery, all calves could walk within 24 hours. Radiographic and clinical evidence of fracture healing was present five to seven weeks (mean 6) after surgery. At that time, the pins and cast material were removed. Return to normal function was rapid and judged to be excellent at follow-up evaluation five to nine months later.Advantages of transfixation pinning and casting in management of radial-ulnar fractures include flexibility in pin positioning, adequate maintenance of reduction, early return to weight-bearing status, preservation of joint mobility, and ease of ambulation. The inability to adjust fixation and alignment after cast application is a disadvantage of this technique compared with other external fixators. We concluded that transfixation pinning is a useful means of stabilizing radial-ulnar fractures in pediatric bovine patients.

  11. Electric arc radius and characteristics

    International Nuclear Information System (INIS)

    Fang, T.M.

    1980-01-01

    The heat transfer equation of an arc discharge has been solved. The arc is assumed to be a cylinder with negligible axial variation and the dominant heat transfer process is conduction radially inside the column and radiation/convection at the outside edge. The symmetric consideration allows a simple one-dimensional formulation. By taking into account proper variation of the electrical conductivity as function of temperature, the heat balance equation has been solved analytically. The radius of the arc and its current-field characteristics have also been obtained. The conventional results that E approx. I 0 5385 and R approx. I 0 7693 with E being the applied field, I the current, and R the radius of the cylindrical arc, have been proved to be simply limiting cases of our more general characteristics. The results can be applied quite widely including, among others, the neutral beam injection project in nuclear fusion and MHD energy conversion

  12. Emprego de fixador externo circular no tratamento de complicações de fraturas do rádio e ulna em cães de raças pequenas Use of circular external fixator in the treatment of fracture complications of radius and ulna in small breed dogs

    Directory of Open Access Journals (Sweden)

    Sheila Canevese Rahal

    2005-10-01

    Full Text Available O objetivo deste estudo foi avaliar o método de Ilizarov no tratamento de complicações de fraturas do rádio e ulna em cães de raças pequenas. Um fixador de Ilizarov miniatura composto por anéis de alumínio e hastes de aço foi usado em três cães da raça poodle miniatura (casos 1, 2 e 3 e em um pinscher (caso 4. Os cães 1 e 4 apresentavam consolidação atrasada das porções médio-distal e distal, respectivamente, devido a prévio tratamento com tala externa. Foi aplicada uma montagem constituída por dois anéis proximais e um distal. Ambas as fraturas consolidaram, sendo que a do poodle apresentou leve desvio cranial das extremidades fraturadas. Os outros dois casos (2 e 3 consistiam de fraturas previamente tratadas por procedimento cirúrgico. O caso 2 apresentava rotação lateral do membro torácico e não-união do aspecto distal da diáfise radial com presença de pino intramedular e dois fios de cerclagem. O pino intramedular e um dos fios de cerclagem foram removidos e realizou-se a derrotação do foco da fratura. O aparelho foi montado como nos casos 1 e 4. A consolidação da fratura foi obtida com moderado desvio caudal do eixo ósseo. No caso 3, havia reabsorção óssea na diáfise do rádio e ulna devido ao emprego inadequado de fixador externo resina-pino. Empregou-se o transporte ósseo com o fixador de Ilizarov para induzir a regeneração óssea. Entretanto, este foi interrompido por falta de resposta. Manteve-se o fixador e o defeito ósseo foi tratado com enxerto esponjoso autólogo e biomateriais. A ulna ocupou parte do defeito segmentar do rádio. Foi possível concluir que o método de Ilizarov pode ser usado no tratamento de consolidação atrasada e não-união, mas o fixador externo circular é de difícil aplicação em cães de raças pequenas.The aim of this study was to evaluate the Ilizarov’s method for treating complications of radius and ulna fractures in small breed dogs. A miniature Ilizarov

  13. On joint numerical radius II

    Czech Academy of Sciences Publication Activity Database

    Drnovšek, R.; Müller, Vladimír

    2014-01-01

    Roč. 62, č. 9 (2014), s. 1197-1204 ISSN 0308-1087 R&D Projects: GA ČR GA201/09/0473; GA AV ČR IAA100190903 Institutional support: RVO:67985840 Keywords : joint numerical range * numerical radius Subject RIV: BA - General Mathematics Impact factor: 0.738, year: 2014 http://www.tandfonline.com/doi/abs/10.1080/03081087.2013.816303

  14. Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

    Directory of Open Access Journals (Sweden)

    Colin Murphy

    2016-04-01

    Full Text Available Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize the fragments prior to percutaneous fixation with sacroiliac screws.

  15. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    Science.gov (United States)

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  16. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  17. Fluoroscopy-guided reduction and fibular nail fixation to manage unstable ankle fractures in patients with diabetes: a retrospective cohort study.

    Science.gov (United States)

    Ashman, B D; Kong, C; Wing, K J; Penner, M J; Bugler, K E; White, T O; Younger, A S E

    2016-09-01

    Patients with diabetes are at increased risk of wound complications after open reduction and internal fixation of unstable ankle fractures. A fibular nail avoids large surgical incisions and allows anatomical reduction of the mortise. We retrospectively reviewed the results of fluoroscopy-guided reduction and percutaneous fibular nail fixation for unstable Weber type B or C fractures in 24 adult patients with type 1 or type 2 diabetes. The re-operation rate for wound dehiscence or other indications such as amputation, mortality and functional outcomes was determined. Two patients developed lateral side wound infection, one of whom underwent wound debridement. Three other patients required re-operation for removal of symptomatic hardware. No patient required a below-knee amputation. Six patients died during the study period for unrelated reasons. At a median follow-up of 12 months (7 to 38) the mean Short Form-36 Mental Component Score and Physical Component Score were 53.2 (95% confidence intervals (CI) 48.1 to 58.4) and 39.3 (95% CI 32.1 to 46.4), respectively. The mean Visual Analogue Score for pain was 3.1 (95% 1.4 to 4.9). The mean Ankle Osteoarthritis Scale total score was 32.9 (95% CI 16.0 to 49.7). Fluoroscopy-guided reduction and fibular nail fixation of unstable ankle fractures in patients with diabetes was associated with a low incidence of wound and overall complications, while providing effective surgical fixation. Cite this article: Bone Joint J 2016;98-B:1197-1201. ©2016 The British Editorial Society of Bone & Joint Surgery.

  18. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    Science.gov (United States)

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    Science.gov (United States)

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  20. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    Science.gov (United States)

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  1. The radius of RX Eridani

    International Nuclear Information System (INIS)

    Woolley, R.; Dean, J.

    1976-01-01

    Photoelectric observations of the light curves of RX Eri obtained in B, V and I, and radial velocity determinations, are combined to determine the radius by a method originally proposed by van Hoof which avoids matching colours in the rising and falling branches of the light curve and concentrates on the falling branch. The results agree well with those from other stars determined by the normal Baade-Wesselink method, but the method is easier to apply if the colour curve is flat in the falling branch. The parameters found for the star are r 0 = 5.5 Sun, mass = 0.45 Sun, and Msub(v) = + 0sup(m).54. (author)

  2. Isolated fracture of pisiform: case report of a rare injury of wrist

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    ABSTRACT: Isolated fracture of the pisiform is an extremely rare injury. Generally fractures of the pisiform are associated with fractures of other carpal bones or the distal radius. Fractures of the carpals and metacarpals account for roughly 6% of all fractures. The average incidence of pisiform fractures is 0.2% of all carpal ...

  3. Occupational therapy and Colles' fractures.

    Science.gov (United States)

    Christensen, O M; Kunov, A; Hansen, F F; Christiansen, T C; Krasheninnikoff, M

    2001-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups at any time. It seems that for non-surgically treated patients with a distal radius fracture only instructions are necessary.

  4. Bone density of the radius, spine, and proximal femur in osteoporosis

    International Nuclear Information System (INIS)

    Mazess, R.B.; Barden, H.; Ettinger, M.; Schultz, E.

    1988-01-01

    Bone mineral density (BMD) was measured in 140 normal young women (aged 20 to 39 years) and in 423 consecutive women over age 40 referred for evaluation of osteoporosis. Lumbar spine and proximal femur BMD was measured using dual-photon absorptiometry ( 153 Gd), whereas the radius shaft measurement used single-photon absorptiometry ( 125 I). There were 324 older women with no fractures, of which 278 aged 60 to 80 years served as age-matched controls. There were 99 women with fractures including 32 with vertebral and 22 with hip fractures. Subsequently, another 25 women with hip fractures had BMD measured in another laboratory; their mean BMD was within 2% of that of the original series. The mean age in both the nonfracture and fracture groups was 70 +/- 5 years. The BMD in the age-matched controls was 20% to 25% below that of normal young women for the radius, spine, and femur, but the Ward's triangle region of the femur showed even greater loss (35%). The mean BMD at all sites in the crush fracture cases was about 10% to 15% below that of age-matched controls. Spinal abnormality was best discriminated by spine and femoral measurements (Z score about 0.9). In women with hip fractures, the BMD was 10% below that of age-matched controls for the radius and the spine, and the BMD for the femoral sites was about 25% to 30% below that of age-matched control (Z score about 1.6). Femoral densities gave the best discrimination of hip fracture cases and even reflected spinal osteopenia. In contrast, neither the spine nor the radius reflected the full extent of femoral osteopenia in hip fracture

  5. Accelerated rehabilitation compared with a standard protocol after distal radial fractures treated with volar open reduction and internal fixation: a prospective, randomized, controlled study.

    Science.gov (United States)

    Brehmer, Jess L; Husband, Jeffrey B

    2014-10-01

    There are relatively few studies in the literature that specifically evaluate accelerated rehabilitation protocols for distal radial fractures treated with open reduction and internal fixation (ORIF). The purpose of this study was to compare the early postoperative outcomes (at zero to twelve weeks postoperatively) of patients enrolled in an accelerated rehabilitation protocol with those of patients enrolled in a standard rehabilitation protocol following ORIF for a distal radial fracture. We hypothesized that patients with accelerated rehabilitation after volar ORIF for a distal radial fracture would have an earlier return to function compared with patients who followed a standard protocol. From November 2007 to November 2010, eighty-one patients with an unstable distal radial fracture were prospectively randomized to follow either an accelerated or a standard rehabilitation protocol after undergoing ORIF with a volar plate for a distal radial fracture. Both groups began with gentle active range of motion at three to five days postoperatively. At two weeks, the accelerated group initiated wrist/forearm passive range of motion and strengthening exercises, whereas the standard group initiated passive range of motion and strengthening at six weeks postoperatively. Patients were assessed at three to five days, two weeks, three weeks, four weeks, six weeks, eight weeks, twelve weeks, and six months postoperatively. Outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) scores (primary outcome) and measurements of wrist flexion/extension, supination, pronation, grip strength, and palmar pinch. The patients in the accelerated group had better mobility, strength, and DASH scores at the early postoperative time points (zero to eight weeks postoperatively) compared with the patients in the standard rehabilitation group. The difference between the groups was both clinically relevant and statistically significant. Patients who follow an accelerated rehabilitation

  6. [True/Flex intramedullary nailing for forearm shaft fractures. Long-term results].

    Science.gov (United States)

    Trlica, J; Počepcov, I; Kočí, J; Frank, M; Holeček, T; Dědek, T

    2012-01-01

    Presentation of technical experience and the clinical and functional results of intramedullary fixation of forearm shaft fractures. Between January 1994 and December 2009, a total of 96 patients with 144 radial and/or ulnar fractures (ulna, 33; radius,15; both, 48) were treated by nailing (True/Flex®). According to the AO classification there were 22-A, 22-B and 22-C type fractures in 39 (41%), 44 (46%) and 13 (13%).cases, respectively. Of these, 82 (85%) were closed (types: 0, 48; I, 33; II, 1) and 14 (15%) were open (types: I, 13; II, 1; III, 0) fractures. Seventy-eight patients (81%) were followed up and their functional outcomes were evaluated according to the criteria of Anderson et al. The average interval between the operation and final follow-up was 28 months (15 to 96 months) The average time to surgery was 2.2 days (0 to 25 days). Early complications were recorded in 4% of the patients (1x bursitis olecrani; 1x end cup replacement; 1x bending of nails) and late complications in 15% (5x non-union; 2x delay union; 4x bursitis olecrani; 1x ruptured tendon). Bone healing was achieved in 95% of the cases and took on average 16 weeks (7 to 34 weeks). No infection, refracture or synostosis occurred. Primary loss of reduction was recorded in four cases due to distraction in one, bent nails in two and a wrong size of the implant in one; secondary loss of reduction was found in three cases, with two cases of radius shortening and one 10°malrotation. No primary malrotation was recorded, but secondary loss of alignment was seen in the distal part of the radius and the proximal part of the ulna. Functional results according to the Anderson criteria were excellent and good in 87% of the cases. Intramedullary mailing provides good stability to mid- and distal-third shaft fractures of the ulna and mid- and proximalthird shaft fractures of the radius, particularly in AO type A and type B fractures. The technical aspects of the method are analysed in detail in this paper

  7. Fracture Mechanics

    International Nuclear Information System (INIS)

    Jang, Dong Il; Jeong, Gyeong Seop; Han, Min Gu

    1992-08-01

    This book introduces basic theory and analytical solution of fracture mechanics, linear fracture mechanics, non-linear fracture mechanics, dynamic fracture mechanics, environmental fracture and fatigue fracture, application on design fracture mechanics, application on analysis of structural safety, engineering approach method on fracture mechanics, stochastic fracture mechanics, numerical analysis code and fracture toughness test and fracture toughness data. It gives descriptions of fracture mechanics to theory and analysis from application of engineering.

  8. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  9. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    incisions for radius and ulna and preservation of the natural curves of radius will lessen the rate of complications. Rigid fixation of fractures after perfect anatomical reduction with 3.5 mm DCP and screws allows early mobilisation, prevents soft tissue contracture, muscular tethering and improves vascularity. A minimum of 6 cortices have to be fixed in each fracture fragment and the nearest screw to the fracture line should be at least 1 cm away. It minimises vascular damage to the plated bone segment.

  10. Radiological study of the secondary reduction effect of early functional exercise on displaced intra-articular calcaneal fractures after internal compression fixation.

    Science.gov (United States)

    Chen, Wei; Liu, Bo; Lv, Hongzhi; Su, Yanling; Chen, Xiao; Zhu, Yanbin; Du, Chenguang; Zhang, Xiaolin; Zhang, Yingze

    2017-09-01

    Early post-operative exercise and weight-bearing activities are found to improve the functional recovery of patients with displaced intra-articular calcaneal fractures (DIACFs). We hypothesized that early functional exercise after surgery might have a secondary reduction effect on the subtalar joint, in particular the smaller fracture fragments that were not fixed firmly. A prospective study was conducted to verify this hypothesis. From December 2012 to September 2013, patients with unilateral DIACFs were enrolled and received a treatment consisting of percutaneous leverage and minimally invasive fixation. After surgery, patients in the study group started exercising on days two to three, using partial weight bearing starting week three, and full weight bearing starting week 12. Patients in the control group followed a conventional post-operative protocol of partial weight bearing after week six and full weight bearing after the bone healed. Computed tomography (CT) scanning was performed at post-operative day one, week four, week eight, and week 12 to reconstruct coronal, sagittal, and axial images, on which the maximal residual displacements of the fractures were measured. Function was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale at the 12th post-operative month. Twenty-eight patients in the study group and 32 in the control group were followed up for more than 12 months; their data were collected and used for the final analysis. Repeated-measures analysis of variance (ANOVA) of the maximal residual displacements of the fracture measured on CT images revealed significant differences between the study and the control groups. There were interaction effects between group and time point. Except for the first time point, the differences between the groups at all studied time points were significant. In the study group, the differences between all studied time points were significant. Strong correlations were observed between

  11. Puzzling out the proton radius puzzle

    Directory of Open Access Journals (Sweden)

    Mihovilovič Miha

    2014-01-01

    Full Text Available The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the best present value obtained from the elastic scattering experiments, remains unexplained and represents a burning problem of today’s nuclear physics: after more than 50 years of research the radius of a basic constituent of matter is still not understood. This paper presents a summary of the best existing proton radius measurements, followed by an overview of the possible explanations for the observed inconsistency between the hydrogen and the muonic-hydrogen data. In the last part the upcoming experiments, dedicated to remeasuring the proton radius, are described.

  12. Puzzling out the proton radius puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Mihovilovič, M.; Merkel, H.; Weber, A. [Institut für Kernphysik, Johannes Gutenberg-Universität Mainz, Johann-Joachim-Becher-Weg 45, 55128 Mainz (Germany)

    2016-01-22

    The discrepancy between the proton charge radius extracted from the muonic hydrogen Lamb shift measurement and the best present value obtained from the elastic scattering experiments, remains unexplained and represents a burning problem of today’s nuclear physics: after more than 50 years of research the radius of a basic constituent of matter is still not understood. This paper presents a summary of the best existing proton radius measurements, followed by an overview of the possible explanations for the observed inconsistency between the hydrogen and the muonic-hydrogen data. In the last part the upcoming experiments, dedicated to remeasuring the proton radius, are described.

  13. Critical cladding radius for hybrid cladding modes

    Science.gov (United States)

    Guyard, Romain; Leduc, Dominique; Lupi, Cyril; Lecieux, Yann

    2018-05-01

    In this article we explore some properties of the cladding modes guided by a step-index optical fiber. We show that the hybrid modes can be grouped by pairs and that it exists a critical cladding radius for which the modes of a pair share the same electromagnetic structure. We propose a robust method to determine the critical cladding radius and use it to perform a statistical study on the influence of the characteristics of the fiber on the critical cladding radius. Finally we show the importance of the critical cladding radius with respect to the coupling coefficient between the core mode and the cladding modes inside a long period grating.

  14. A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture.

    Science.gov (United States)

    Mittal, Yogesh; Varghese, K George; Mohan, S; Jayakumar, N; Chhag, Somil

    2016-03-01

    Three dimensional titanium plating system was developed by Farmand in 1995 to meet the requirements of semi rigid fixation with lesser complication. The purpose of this in vivo prospective study was to evaluate and compare the clinical effectiveness of three dimensional and two dimensional Titanium miniplates for open reduction and fixation of mandibular parasymphysis fracture. Thirty patients with non-comminuted mandibular parasymphysis fractures were divided randomly into two equal groups and were treated with 2 mm 3D and 2D miniplate system respectively. All patients were systematically monitored at 1st, 2nd, 3rd, 6th week, 3rd and 6th month postoperatively. The outcome parameters recorded were severity of pain, infection, mobility, occlusion derangement, paresthesia and implant failure. The data so collected was analyzed using independent t test and Chi square test (α = .05). The results showed that one patient in each group had post-operative infection, occlusion derangement and mobility (p > .05). In Group A, one patient had paresthesia while in Group B, two patients had paresthesia (p > .05). None of the patients in both the groups had implant failure. There was no statistically significant difference between 3D and 2D miniplate system in all the recorded parameters at all the follow-ups (p > .05). 3D miniplates were found to be better than 2D miniplates in terms of cost, ease of surgery and operative time. However, 3D miniplates were unfavorable for cases where fracture line was oblique and in close proximity to mental foramen, where they were difficult to adapt and more chances for tooth-root damage and inadvertent injury to the mental nerve due to traction.

  15. The efficacy of mobile application use on recall of surgical risks in nasal bone fracture reduction surgery.

    Science.gov (United States)

    Kim, Choong Hyeon; Cheon, Ji Seon; Choi, Woo Young; Son, Kyung Min

    2018-03-01

    The number of surgical risks recalled by a patient after surgery can be used as a parameter for assessing how well the patient has understood the informed consent process. No study has investigated the usefulness of a self-developed mobile application in the traditional informed consent process in patients with a nasal bone fracture. This study aimed to investigate whether delivery of information, such as surgical risks, through a mobile application is more effective than delivery of information through only verbal means and a paper. This prospective, randomized study included 60 patients with a nasal bone fracture. The experimental group (n=30) received preoperative explanation with the traditional informed consent process in addition to a mobile application, while the control group (n=30) received preoperative explanation with only the traditional informed consent process. Four weeks after surgery, the number of recalled surgical risks was compared for analysis. The following six surgical risks were explained: pain, bleeding, nasal deformity, numbness, nasal obstruction, and nasal cartilage necrosis. The mean number of recalled surgical risks among all patients was 1.58±0.56. The most frequently recalled surgical risk was nasal deformity in both groups. The mean number of recalled surgical risks was 1.72±0.52 in the experimental group and 1.49±0.57 in the control group. There was a significant association between mobile application use and the mean number of recalled surgical risks ( p =0.047). Age, sex, and the level of education were not significantly associated with the mean number of recalled surgical risks. This study found that a mobile application could contribute to the efficient delivery of information during the informed consent process. With further improvement, it could be used in other plastic surgeries and other surgeries, and such an application can potentially be used for explaining risks as well as delivering other types of information.

  16. Fractal analysis of bone architecture at distal radius

    International Nuclear Information System (INIS)

    Tomomitsu, Tatsushi; Mimura, Hiroaki; Murase, Kenya; Sone, Teruki; Fukunaga, Masao

    2005-01-01

    Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass. (author)

  17. Fixador esquelético pino-resina acrílica e enxerto ósseo esponjoso no tratamento de complicações secundárias à imobilização inadequada de fratura do rádio e ulna em cães Acrylic-pin external fixator and cancellous bone graft in the treatment of complications caused by inadequate immobilization of radius and ulna fracture in dogs

    Directory of Open Access Journals (Sweden)

    Sheila Canevese Rahal

    2005-10-01

    Full Text Available O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4, osteomielite (n=1, má-união (n=1, falência ou quebra de implante (n=4, sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. Em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.The aim of this study was to evaluate the acrylic-pin external fixator, type II-configuration, and cancellous bone autograft for treating complications of radius and ulna fractures in 10 dogs weighing between 1.8 and 33.6 kg. Nonunion (n=4, osteomyelitis (n=1, malunion (n=1, failure or breakage of implant (n=4 were detected, and 60 % of them were associated with previous intramedullary pin placement in the radius. The fixator frame was constructed using most of the smooth transfixation pins angled. The fixation rods were constructed by placing acrylic resin over the ends of the transfixation pins that were previously bent. In all cases fresh cancellous bone autograft was used after cleaning of the fracture site. The permanence time of the external fixator ranged from 45 days to 5 months, and the most important complication was pin loosening. Fracture healing was by minimal to moderate periosteal callus, suggesting good rigidity

  18. Orthopedic infections in equine long bone fractures and arthrodeses treated by internal fixation: 192 cases (1990-2006).

    Science.gov (United States)

    Ahern, Benjamin J; Richardson, Dean W; Boston, Raymond C; Schaer, Thomas P

    2010-07-01

    To determine the rate of postoperative infection (POI) for internal fixation repaired equine long bone fractures and arthrodeses and identify associated risk factors. Case series. Horses (n=192) with fracture repair of the third metacarpal and metatarsal bones, radius, ulna, humerus, tibia, and femur, or arthrodesis with internal fixation. Medical records (1990-2006) were reviewed for signalment, anatomic location, fracture classification and method of repair, technique and surgical duration, bacterial species isolated, postoperative care, onset of POI, and outcome. Of 192 horses (171 [89%] closed, 21 [11%] open fractures), 157 (82%) were discharged from the hospital. Infection occurred in 53 (28% horses), of which 31 (59%) were discharged. Repairs without POI were 7.25 times more likely to be discharged from the hospital. Closed fractures were 4.23 times more likely to remain uninfected and 4.59 times more likely to be discharged from the hospital compared with open fractures. Closed reduction and internal fixation was associated with a 2.5-fold reduction in rate of POI and a 5.9 times greater chance for discharge from the hospital compared with open reduction and internal fixation. Females had a strong trend for increased POI when compared with colts and stallion but not geldings. Overall rate of POI was 28%. Fracture classification, method of repair, gender, and surgical duration were significant risk factors.

  19. Evaluation the treatment outcomes of intracapsular femoral neck fractures with closed or open reduction and internal fixation by screw in 18-50-year-old patients in Isfahan from Nov 2010 to Nov 2011

    Directory of Open Access Journals (Sweden)

    Mohammad Javdan

    2013-01-01

    Conclusion: This study showed that femoral neck fracture is associated with several complications, especially if open reduction was necessary. So, the surgical method and necessary equipments such as radiolucent bed, C-ARM machine, and implant cannulated screw set should be considered.

  20. Nuclear charge radius of $^{12}$Be

    CERN Document Server

    Krieger, Andreas; Bissell, Mark L; Frömmgen, Nadja; Geppert, Christopher; Hammen, Michael; Kreim, Kim; Kowalska, Magdalena; Krämer, Jörg; Neff, Thomas; Neugart, Rainer; Neyens, Gerda; Nörtershäuser, Wilfried; Novotny, Christian; Sanchez, Rodolfo; Yordanov, Deyan T

    2012-01-01

    The nuclear charge radius of $^{12}$Be was precisely determined using the technique of collinear laser spectroscopy on the $2s_{1/2}\\rightarrow 2p_{1/2, 3/2}$ transition in the Be$^{+}$ ion. The mean square charge radius increases from $^{10}$Be to $^{12}$Be by $\\delta ^{10,12} = 0.69(5)$ fm$^{2}$ compared to $\\delta ^{10,11} = 0.49(5)$ fm$^{2}$ for the one-neutron halo isotope $^{11}$Be. Calculations in the fermionic molecular dynamics approach show a strong sensitivity of the charge radius to the structure of $^{12}$Be. The experimental charge radius is consistent with a breakdown of the N=8 shell closure.

  1. CURBSIDE CONSULTATION IN FRACTURE MANAGEMENT: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Walter W. Virkus

    2008-12-01

    Full Text Available DESCRIPTION: A user-friendly, unique resource for the treatment of fractures designed in a casual questions and answers format which provides basic knowledge, current information and evidence based expert advices enhanced by images and diagrams and supported by ref-erences.PURPOSE: Designing this book the editor has aimed to prepare not only a source of current knowledge and opin-ions by experienced authors in fracture management for decision making in daily practice but also a brief refer-ence and useful educational resource in orthopedic trauma surgery.FEATURES: Three Sections are composed of 49 sub-jects in a form of the answers of frequently asked ques-tions richly illustrated by images and diagrams and in-cluding references at the end of each subject.The Section I is “UPPER EXTREMITIES” including: Neck fracture; Humerus shaft fracture; Management of radial nerve palsy associated with humeral fracture; Clavicle fractures; Elbow fractures in children; Fasciot-omy technic of the forearm; Distal radius fracture; Indica-tions of radial head replacement, Femur and humeral shaft fractures; Treatment of posterolateral elbow dislocation; The Section II is “LOWER EXTREMITIES” including : Femur fractures; Pelvic fractures; Life threatening pelvic fractures; Decision for surgical treatment in pelvic frac-tures; Treatment of anterior fracture of femoral head and hip joint incongruity; Management of a displaced femoral neck fracture in young patient in ER; Elder patients with displaced femoral head fracture; Patella and tibial plateau fractures; Criteria for compartment syndromes in the tibia; Tricks in nailing proximal and distal tibial fractures; Surgical management of distal tibia spiral fracture in middle aged women; Pilon fracture; Management of syn-desmotic screws in adult patient; The management of minimally displaced posterior malleol in three malleolar fractures; Postoperative management of bimalleolar frac-tures; Management of minimally

  2. Occupational therapy and Colles' fractures

    OpenAIRE

    Christensen, O.M.; Kunov, A.; Hansen, F.F.; Christiansen, T.C.; Krasheninnikoff, M.

    2000-01-01

    In this randomized trial, we enrolled 30 patients treated for a distal radius Colles' type fracture. The fractures were reduced if necessary and fixed in a below-elbow plaster cast for 5 weeks. One group consisting of 14 patients received instructions for shoulder; elbow and finger exercise and the other group consisting of 16 patients had occupational therapy. At 5 weeks, 3 and 9 months we measured the functional scores. There were no statistically significant differences between the groups ...

  3. Orthopaedic resident preparedness for closed reduction and pinning of pediatric supracondylar fractures is improved by e-learning: a multisite randomized controlled study.

    Science.gov (United States)

    Hearty, Thomas; Maizels, Max; Pring, Maya; Mazur, John; Liu, Raymond; Sarwark, John; Janicki, Joseph

    2013-09-04

    There is a need to provide more efficient surgical training methods for orthopaedic residents. E-learning could possibly increase resident surgical preparedness, confidence, and comfort for surgery. Using closed reduction and pinning of pediatric supracondylar humeral fractures as the index case, we hypothesized that e-learning could increase resident knowledge acquisition for case preparation in the operating room. An e-learning surgical training module was created on the Computer Enhanced Visual Learning platform. The module provides a detailed and focused road map of the procedure utilizing a multimedia format. A multisite prospective randomized controlled study design compared residents who used a textbook for case preparation (control group) with residents who used the same textbook plus completed the e-learning module (test group). All subjects completed a sixty-question test on the theory and methods of the case. After completion of the test, the control group then completed the module as well. All subjects were surveyed on their opinion regarding the effectiveness of the module after performing an actual surgical case. Twenty-eight subjects with no previous experience in this surgery were enrolled at four academic centers. Subjects were randomized into two equal groups. The test group scored significantly better (p < 0.001) and demonstrated competence on the test compared with the control group; the mean correct test score (and standard deviation) was 90.9% ± 6.8% for the test group and 73.5% ± 6.4% for the control group. All residents surveyed (n = 27) agreed that the module is a useful supplement to traditional methods for case preparation and twenty-two of twenty-seven residents agreed that it reduced their anxiety during the case and improved their attention to surgical detail. E-learning using the Computer Enhanced Visual Learning platform significantly improved preparedness, confidence, and comfort with percutaneous closed reduction and pinning of a

  4. Two new methods for the determination of hydraulic fracture ...

    African Journals Online (AJOL)

    2008-09-15

    Sep 15, 2008 ... Flow is radial and divergent. • There is only a single fracture within the test segment. • The fracture and rock mass are rigid and the matrix is imper- meable. • The fracture aperture varies along the radius and is radically symmetrical about the borehole. • Advection, dispersion and diffusion are negligible due ...

  5. Transstyloid, transscaphoid, transcapitate fracture: a variant of scaphocapitate fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2014-01-01

    Transstyloid, transscaphoid, transcapitate fractures are uncommon. We report the case of a 28-year-old man who sustained this fracture following direct trauma. The patient was successfully treated by open reduction internal fixation of the scaphoid and proximal capitate fragment, with a good clinical outcome at 1-year follow-up. This pattern is a new variant of scaphocapitate fracture as involves a fracture of the radial styloid as well.

  6. A Maximum Radius for Habitable Planets.

    Science.gov (United States)

    Alibert, Yann

    2015-09-01

    We compute the maximum radius a planet can have in order to fulfill two constraints that are likely necessary conditions for habitability: 1- surface temperature and pressure compatible with the existence of liquid water, and 2- no ice layer at the bottom of a putative global ocean, that would prevent the operation of the geologic carbon cycle to operate. We demonstrate that, above a given radius, these two constraints cannot be met: in the Super-Earth mass range (1-12 Mearth), the overall maximum that a planet can have varies between 1.8 and 2.3 Rearth. This radius is reduced when considering planets with higher Fe/Si ratios, and taking into account irradiation effects on the structure of the gas envelope.

  7. Study Application of RADIUS Protocol on Ethernet

    Institute of Scientific and Technical Information of China (English)

    GUO Fang; YANG Huan-yu; LI Hong

    2004-01-01

    This paper presents how to apply the RADIUS (Remote Authentication Dial In User Service)protocol ,which is generally applied to dial-up network, to the authentication & charge of Broad Band accessing control system on Ethernet. It is provided that the Broad Band accessing control system included a self-designed communication protocol is used in communicating between an terminal user and Network Access Server .The interface module on the servers side and the Radius system is also given in this article.

  8. The earth's radius and the G variation

    International Nuclear Information System (INIS)

    Canuto, V.M.; City Coll., New York

    1981-01-01

    It has been assumed that if the gravitational constant G was larger in the past, the Earth's radius had to be smaller. The assertion holds provided the input from microphysics (in particular the equation of state) is independent of G. While this is true for some theories of gravity with variable G it is not so in the scale covariant theory, where the pressure can be affected by a variable G in a way that, for a constant mass of the Earth, a larger G in the past implies a larger Earth's radius. Comparison with recent palaeomagnetic data is presented. (author)

  9. Formability of dual-phase steels in deep drawing of rectangular parts: Influence of blank thickness and die radius

    Science.gov (United States)

    López, Ana María Camacho; Regueras, José María Gutiérrez

    2017-10-01

    The new goals of automotive industry related with environment concerns, the reduction of fuel emissions and the security requirements have driven up to new designs which main objective is reducing weight. It can be achieved through new materials such as nano-structured materials, fibre-reinforced composites or steels with higher strength, among others. Into the last group, the Advance High Strength Steels (AHSS) and particularly, dual-phase steels are in a predominant situation. However, despite of their special characteristics, they present issues related to their manufacturability such as springback, splits and cracks, among others. This work is focused on the deep drawing processof rectangular shapes, a very usual forming operation that allows manufacturing several automotive parts like oil pans, cases, etc. Two of the main parameters in this process which affect directly to the characteristics of final product are blank thickness (t) and die radius (Rd). Influence of t and Rd on the formability of dual-phase steels has been analysed considering values typically used in industrial manufacturing for a wide range of dual-phase steels using finite element modelling and simulation; concretely, the influence of these parameters in the percentage of thickness reduction pt(%), a quite important value for manufactured parts by deep drawing operations, which affects to its integrity and its service behaviour. Modified Morh Coulomb criteria (MMC) has been used in order to obtain Fracture Forming Limit Diagrams (FFLD) which take into account an important failure mode in dual-phase steels: shear fracture. Finally, a relation between thickness reduction percentage and studied parameters has been established fordual-phase steels, obtaining a collection of equations based on Design of Experiments (D.O.E) technique, which can be useful in order to predict approximate results.

  10. Management of osteoporotic vertebral fractures

    OpenAIRE

    Dionyssiotis, Yannis

    2010-01-01

    Yannis DionyssiotisRhodes General Hospital, Rhodes, GreeceAbstract: Osteoporotic vertebral fractures are associated with considerable reduction of quality of life, morbidity, and mortality. The management of patients with vertebral fractures should include treatment for osteoporosis and measures to reduce pain and improve mobility. This article provides information for management and rehabilitation of vertebral fractures based on clinical experience and literature.Keywords: vertebral fracture...

  11. Perbandingan Fungsi Extremitas Atas pada Fraktur Metafise Distal Radius Intraartikuler Usia Muda Antara Tindakan Operatif Dan Non Operatif dengan Penilaian Klinis Quickdash Score

    Directory of Open Access Journals (Sweden)

    Edi Burhan

    2014-01-01

    Full Text Available AbstrakFraktur metafise distal radius merupakan fraktur dengan insiden tertinggi kedua pada usia tua di luar fraktur daerah panggul. Di Rumah Sakit Dr. M. Djamil Padang terdapat 122 dari 612 kasus fraktur radius, antara Januari 2011 – Juni 2012. Tujuan utama terapi ini adalah pengembalian permukaan sendi ke posisi anatomis dengan fiksasi yang stabil dan pengembalian fungsi extremitas atas semaksimal mungkin. Metode: Penelitian ini berupa penelitian retrospektif yang dilakukan di poliklinik orthopaedi RSUP Dr M Djamil Padang pada bulan November-Desember 2012 pada pasien fraktur metafise distal radius intraartikuler usia muda yang mendapat tindakan operatif dibandingkan dengan kelompok non-operatif dengan penilaian klinis Quick DASH Score. Sampel yang digunakan sebanyak 30 orang dari 55 orang yang memenuhi kriteria inklusi. Hasil: Ada hubungan yang bermakna antara fungsi extremitas atas dengan penilaian Quick DASH Score antara tindakan operatif pada fraktur distal radius intraartikuler usia muda dengan tindakan non-operatif (p Fisher = 0,010. Tidak terdapat hubungan bermakna antara Quick DASH Score dengan jenis kelamin dan diagnosa kanan atau kiri. Pembahasan: Terdapat perbedaan yang bermakna antara pasien fraktur metafise distal radius intraartikuler pada usia muda yang mendapat tindakan operatif berupa ORIF dengan yang mendapatkan tindakan non-operatif berupa pemasangan Gips.Kata kunci: Fraktur Metafise Distal Radius, Tindakan Operatif dan Non Operatif, Quick Dash ScoreAbstractFracture metafise distal radius is fracture with second highest incident on old age besides a fracture in the pelvic area. In the Dr. M. Djamil Hospital found 122 from 612 cases fracture of radius from january 2011 to june 2012. The main purpose therapy is restore the joint in the surface position anatomically by fixation a stable and restore the function upper extremitas over their best. Method: This study is a retrospective conducted at the Orthopaedi clinic of Dr M

  12. Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction

    NARCIS (Netherlands)

    Verlaan, Jorrit Jan; Somers, Inne; Dhert, Wouter J A; Oner, F. Cumhur

    2015-01-01

    Background context  When used to fixate traumatic thoracolumbar burst fractures, pedicle screw constructs may fail in the presence of severe vertebral body comminution as the intervertebral disc can creep through the fractured endplates leading to insufficient anterior column support.

  13. Spectral Radius and Hamiltonicity of Graphs

    Czech Academy of Sciences Publication Activity Database

    Fiedler, Miroslav; Nikiforov, V.

    2010-01-01

    Roč. 432, č. 9 (2010), s. 2170-2173 ISSN 0024-3795 Institutional research plan: CEZ:AV0Z10300504 Keywords : Hamiltonian cycle * Hamiltonian path * spectral radius Subject RIV: BA - General Mathematics Impact factor: 1.005, year: 2010

  14. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  15. A Fracture Decoupling Experiment

    Science.gov (United States)

    Stroujkova, A. F.; Bonner, J. L.; Leidig, M.; Ferris, A. N.; Kim, W.; Carnevale, M.; Rath, T.; Lewkowicz, J.

    2012-12-01

    Multiple observations made at the Semipalatinsk Test Site suggest that conducting nuclear tests in the fracture zones left by previous explosions results in decreased seismic amplitudes for the second nuclear tests (or "repeat shots"). Decreased seismic amplitudes reduce both the probability of detection and the seismically estimated yield of a "repeat shot". In order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fractured rocks, Weston Geophysical Corp., in collaboration with Columbia University's Lamont Doherty Earth Observatory, conducted a multi-phase Fracture Decoupling Experiment (FDE) in central New Hampshire. The FDE involved conducting explosions of various yields in the damage/fracture zones of previously detonated explosions. In order to quantify rock damage after the blasts we performed well logging and seismic cross-hole tomography studies of the source region. Significant seismic velocity reduction was observed around the source regions after the initial explosions. Seismic waves produced by the explosions were recorded at near-source and local seismic networks, as well as several regional stations throughout northern New England. Our analysis confirms frequency dependent seismic amplitude reduction for the repeat shots compared to the explosions in un-fractured rocks. The amplitude reduction is caused by pore closing and/or by frictional losses within the fractured media.

  16. Computer simulation of ductile fracture

    International Nuclear Information System (INIS)

    Wilkins, M.L.; Streit, R.D.

    1979-01-01

    Finite difference computer simulation programs are capable of very accurate solutions to problems in plasticity with large deformations and rotation. This opens the possibility of developing models of ductile fracture by correlating experiments with equivalent computer simulations. Selected experiments were done to emphasize different aspects of the model. A difficult problem is the establishment of a fracture-size effect. This paper is a study of the strain field around notched tensile specimens of aluminum 6061-T651. A series of geometrically scaled specimens are tested to fracture. The scaled experiments are conducted for different notch radius-to-diameter ratios. The strains at fracture are determined from computer simulations. An estimate is made of the fracture-size effect

  17. Angular deformation of radius and ulna treated by dynamic percutaneus osteogenesis distraction. Case report

    International Nuclear Information System (INIS)

    Rezende, C.M.F.; Melo, E.G.; Lamas, M.C.S.; Silva, C.A.

    2000-01-01

    The clinical exam of a male mongrel dog, 4-month-old, and 5.7kg of live weight, showed that the dog supported with the elbows and it was observed accentuated bilateral rotacional deformity of the radius and ulna. Radiographs of the radius and ulna revealed proximal fracture of the radius. After clinical and radiographic evaluation it was indicated the corrective osteotomy and distraction osteogenesis of the left foremember. The surgical procedure consisted in osteotomy in the diaphysis of the radius and ulna, and the utilization of external fixators composed by four Kirschner’s pins and two metallic thread bars, configuring a fixator type II, bilateral uniplanar dynamic. Before the fixation of the pins with acrylic, the fractured bony fragments were separated in approximately 0.5cm. Starting 10 days post surgery, the radial osteotomy site was distracted at a rate of 1.0mm every day for 30 days. The consolidation of the osteotomy site was observed radiographically 67 days after the intervention, when the fixator was removed. Similar procedure was accomplished in the right foremember at the age of 16 months. At this moment, it was necessary to remove a coins bony of approximately 1.0cm for correction of the limb angulation. At present, the dog shows normal function and support of the left foremember and light valgus deformity of the right foremember due to the broken implants [pt

  18. early operative management of pilon fractures using the ...

    African Journals Online (AJOL)

    Background: Pilon fractures is a management challenge due to complexity of fracture pattern and ... excellent exposure for accurate fracture reduction and no wound complications in our case ... dehiscence, superficial infection, osteomyelitis,.

  19. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2014-11-01

    Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

  20. Cost Effective RADIUS Authentication for Wireless Clients

    Directory of Open Access Journals (Sweden)

    Alexandru ENACEANU

    2010-12-01

    Full Text Available Network administrators need to keep administrative user information for each network device, but network devices usually support only limited functions for user management. WLAN security is a modern problem that needs to be solved and it requires a lot of overhead especially when applied to corporate wireless networks. Administrators can set up a RADIUS server that uses an external database server to handle authentication, authorization, and accounting for network security issues.

  1. Upper pinch radius limit in EXTRAP

    International Nuclear Information System (INIS)

    Lehnert, B.

    1989-12-01

    A simple static equilibrium model of the Z-pinch is considered where a hot plasma core is surrounded by a cold-mantle (gas blanket). The pinch radius, defined as the radial extension of the fully ionized plasma core, is uniquely determined by the plasma particle. momentum and heat balance equations. In Extrap configurations an octupole field is introduced which imposes a magnetic separatrix on Z-pinch geometry. This makes the conditions for Extrap equilibrium 'overdetermined' when the characteristic pinch radium given by the plasma parameters tends to exceed the characteristic radius of the magnetic separatrix. In this case no conventional pinch equilibrium can exist, and part of the current which is forced into the plasma discharge by external sources must be channelled outside of the separatrix, i.e. into the surrounding support structure of the Extrap conductors and the vessel walls. A possibly existing bootstrap current in the plasma boundary layer is further expected to be 'scraped off' in this case. The present paper gives some illustrations of the marginal case of this upper pinch radius limit, in a state where the pinch current is antiparallel to the external rod currents which generate the octupole field. (authors)

  2. Mass-Radius diagram for compact stars

    International Nuclear Information System (INIS)

    Carvalho, G A; Jr, R M Marinho; Malheiro, M

    2015-01-01

    The compact stars represent the final stage in the evolution of ordinary stars, they are formed when a star ceases its nuclear fuel, in this point the process that sustain its stability will stop. After this, the internal pressure can no longer stand the gravitational force and the star colapses [2]. In this work we investigate the structure of these stars which are described by the equations of Tolman-Openheimer-Volkof (TOV) [1]. These equations show us how the pressure varies with the mass and radius of the star. We consider the TOV equations for both relativistic and non-relativistic cases. In the case of compact stars (white dwarfs and neutron stars) the internal pressure that balances the gravitational pressure is essentialy the pressure coming from the degeneracy of fermions. To have solved the TOV equations we need a equation of state that shows how this internal pressure is related to the energy density or mass density. Instead of using politropic equations of state we have solved the equations numericaly using the exact relativistic energy equation for the model of fermion gas at zero temperature. We obtain results for the mass-radius relation for white dwarfs and we compared with the results obtained using the politropic equations of state. In addition we discussed a good fit for the mass-radius relation. (paper)

  3. Solar radius change between 1925 and 1979

    Science.gov (United States)

    Sofia, S.; Dunham, D. W.; Dunham, J. B.; Fiala, A. D.

    1983-01-01

    From an analysis of numerous reports from different locations on the duration of totality of the solar eclipses on January 24, 1925, and February 26, 1979, it is found that the solar radius at the earlier date was 0.5 arcsec (or 375 km) larger than at the later date. The correction to the standard solar radius found for each eclipse is different when different subsets of the observations are used (for example, edge of path of totality timings compared with central timings). This is seen as suggesting the existence of systematic inaccuracies in our knowledge of the lunar figure. The differences between the corrections for both eclipses, however, are very similar for all subsets considered, indicating that changes of the solar size may be reliably inferred despite the existence of the lunar figure errors so long as there is proper consideration of the distribution of the observations. These results are regarded as strong evidence in support of the occurrence of solar radius changes on shorter than evolutionary time scales.

  4. Solar radius change between 1925 and 1979

    International Nuclear Information System (INIS)

    Sofia, S.; Fiala, A.D.

    1983-01-01

    By analysing numerous reports, from different locations, on the duration of totality of the solar eclipses on 24 January 1925, and on 26 February 1979, it was found that the solar radius at the earlier date was 0.5 arc s, or 375 km larger than at the later date. The correction to the standard solar radius found for each eclipse was different when different subsets of the observations were used (for example, edge of path of totality timings compared with central timings), suggesting the existence of systematic inaccuracies in our knowledge of the lunar figure. However, the differences between the corrections for both eclipses were very similar for all subsets considered, indicating that changes of the solar size may be reliably inferred despite the existence of the lunar figure errors, as long as the proper consideration is made of the distribution of the observations. It is considered that these results are strong evidence in support of the occurrence of solar radius changes on shorter than evolutionary time scales. (author)

  5. Stress fractures in athletes

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Wolf, C.; Gruber, H.; Czermak, B.V.; Mallouhi, A.; Jaschke, W.; Gabriel, M.

    2002-01-01

    Stress fractures may pose a diagnostic dilemma for radiologists since they are sometimes difficult to demonstrate on plain films and may simulate a tumour. They were first described in military personnel and professional athletes. Recently, there is an increasing incidence in the general population due to increasing sportive activities. Stress fractures occur most often in the lower extremities, especially in the tibia, the tarsal bone, the metatarsal bone, the femur and the fibula. In the upper extremities, they are commonly found in the humerus, the radius and the ulna. Some fractures of the lower extremities appear to be specific for particular sports, for example, fractures of the tibia affect mostly distance runners. Whereas stress fractures of the upper extremities are generally associated with upper limb-dominated sports. A correct diagnosis requires a careful clinical evaluation. The initial plain radiography may be normal. Further radiological evaluation could be performed by means of computerised tomography, magnetic resonance imaging and bone scanning. The latter two techniques are especially helpful for establishing a correct initial diagnosis. (orig.) [de

  6. Tibial Plateau Fractures

    DEFF Research Database (Denmark)

    Elsøe, Rasmus

    This PhD thesis reported an incidence of tibial plateau fractures of 10.3/100,000/year in a complete Danish regional population. The results reported that patients treated for a lateral tibial plateau fracture with bone tamp reduction and percutaneous screw fixation achieved a satisfactory level...... with only the subgroup Sport significantly below the age matched reference population. The thesis reports a level of health related quality of life (Eq5d) and disability (KOOS) significantly below established reference populations for patients with bicondylar tibial plateau fracture treated with a ring...... fixator, both during treatment and at 19 months following injury. In general, the thesis demonstrates that the treatment of tibial plateau fractures are challenging and that some disabilities following these fractures must be expected. Moreover, the need for further research in the area, both with regard...

  7. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  8. Mandibular ramus fractures: a rarity.

    Science.gov (United States)

    Kale, Tejraj Pundalik; Kotrashetti, S M; Louis, Archana; Lingaraj, J B; Sarvesh, B U

    2013-01-01

    To determine the incidence of mandibular ramus fractures in KLE's PK Hospital and to analyze the outcome of open reduction and internal fixation of these fractures. Using a retrospective study design, records of all trauma patients who reported to the Department of Oral and Maxillofacial Surgery, KLE's PK Hospital Belgaum, between the years January 2006 to October 2011 was obtained from the medical records office. The data variables that were analyzed were the name, age, sex, cause of injury, pretreatment occlusion, treatment given, period of MMF and post-treatment occlusion. Total number of mandibular fracture cases was 298. Ramus fractures were 10 in number which accounted for 3.3% of fractures. The age range of these 10 patients was seen to be between 20 to 80 years with the average age being 35.6 years. Of these 10 patients, 9 were male and 1 was female and 7 patients were treated by open reduction and internal fixation and the remaining 3 by closed reduction. The average period of MMF was 3 days for the patients who underwent open reduction and internal fixation. There was improvement in occlusion in all 10 patients post-treatment and there was no complication reported in any of the cases. Ramus fractures accounted for 3.3% of all mandibular fractures. Open reduction and internal fixation of ramus fractures ensures adequate functional and anatomic reduction. This study makes an attempt to throw a light on the increasing incidence of ramus fractures and a successful management of these fractures by open reduction and internal fixation. How to cite this article: Kale TP, Kotrashetti SM, Louis A, Lingaraj JB, Sarvesh BU. Mandibular Ramus Fractures: A Rarity. J Contemp Dent Pract 2013;14(1):39-42. Source of support: Nil Conflict of interest: None declared.

  9. Comparative evaluation of rotary ProTaper, Profile, and conventional stepback technique on reduction in Enterococcus faecalis colony-forming units and vertical root fracture resistance of root canals.

    Science.gov (United States)

    Singla, Mamta; Aggarwal, Vivek; Logani, Ajay; Shah, Naseem

    2010-03-01

    The purpose of this in vitro study was to evaluate the effect of various root canal instrumentation techniques with different instrument tapers on cleaning efficacy and resultant vertical root fracture (VRF) strength of the roots. Fifty human mandibular first premolar roots were enlarged to ISO size 20, inoculated with Enterococcus faecalis [ATCC2912] for 72 hours and divided into 5 groups: group I: prepared with .02 taper hand instruments ISO size 40; group II: Profile .04 taper size 40; group III: Profile .06 taper size 40; group IV: ProTaper size F4; and group V (control group) further divided into: Va: with bacterial inoculation and no mechanical instrumentation; and Group Vb: neither bacterial inoculation nor mechanical instrumentation. Cleaning efficacy was evaluated in terms of reduction of colony forming units (CFUs). The VRF strength was evaluated using D11 spreader as wedge in an Instron testing machine. Root canals instrumented with ProTaper and 6% Profile instruments showed maximum reduction in CFUs, with statistically insignificant difference between them. The VRF resistance decreased in all instrumented groups. The difference of VRF between 2% and 4% taper Profile groups was statistically insignificant (P = .195). One-way analysis of variance showed that canals instrumented with ProTaper F4 showed maximum reduction in VRF resistance compared with control uninstrumented group. Profile 6% taper instruments offer the advantage of maximum debridement without significant reduction in root fracture resistance. Copyright 2010 Mosby, Inc. All rights reserved.

  10. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    Science.gov (United States)

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  11. A measurement of the pion charge radius

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Badelek, B.; Batignani, G.; Bedeschi, F.; Bertolucci, E.; Bettoni, D.; Bosisio, L.; Bradaschia, C.; Dell'Orso, M.; Fidecaro, F.; Foa, L.; Focardi, E.; Giazotto, A.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Scribano, A.; Tonelli, G.; Codino, A.; Fabbri, F.L.; Laurelli, P.; Satta, L.; Spillantini, P.; Zallo, A.; Counihan, M.J.; Frank, S.G.F.; Harvey, J.; Storey, D.; Menasce, D.; Meroni, E.; Moroni, L.

    1984-01-01

    We report a measurement of the negative pion electromagnetic form factor in the range of space-like four-momentum transfer 0.014 2 2 . The measurement was made by the NA7 collaboration at the CERN SPS, by observing the interaction of 300 GeV pions with the electrons of a liquid hydrogen target. The form factor is fitted by a pole form with a pion radius of (rho 2 )sup(1/2) = 0.657 +- 0.012 fm. (orig.)

  12. A measurement of the kaon charge radius

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Batignani, G.; Bertolucci, E.; Bosisio, L.; Bradaschia, C.; Dell'Orso, M.; Fidecaro, F.; Foa, L.; Focardi, E.; Gianetti, P.; Giazzotto, A.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Scribano, A.; Tonelli, G.; Triggiani, G.; Beck, G.A.; Bologna, G.; D'Ettorre Piazzoli, B.; Mannocchi, G.; Picchi, P.; Budinich, M.; Liello, F.; Ragusa, F.; Rolandi, L.; Stefanini, A.; Fabbri, F.L.; Laurelli, P.; Zallo, A.; Gren, M.G.; Landon, M.P.J.; March, P.V.; Strong, J.A.; Tenchini, R.; Meroni, E.

    1986-01-01

    The negative kaon electromagnetic form factor has been measured in the space-like q 2 range 0.015-0.10 (GeV/c) 2 by the direct scattering of 250 GeV kaons from electrons at the CERN SPS. It is found that the kaon mean square charge radius K 2 >=0.34±0.05 fm 2 . From data collected simultaneously for πe scattering, the difference between the charged pion and kaon mean square radii (which is less sensitive to systematic errors) is found to be π 2 >- K 2 >=0.10±0.045 fm 2 . (orig.)

  13. Small-radius jets to all orders

    CERN Document Server

    Cacciari, Matteo; Soyez, Gregory; Salam, Gavin; Dasgupta, Mrinal

    2015-01-01

    With hadron colliders continuing to push the boundaries of precision, it is becoming increas­ ingly important to have a detailed understanding of the subtleties appearing at smaller values of the jet radius R. We present a method to resum all leading logarithmic terms, a'.; Inn R, using a generating functional approach, as was recently discussed in Ref. 1. We study a variety of observables, such as the inclusive jet spectrum and jet vetoes for Higgs physics, and show that small-R effects can be sizeable. Finally, we compare our calculations to existing ALICE data, and show good agreement.

  14. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    , 31-A2) and intertrochanteric (31-A3) fractures is considered an important approach because of their different behaviour at reduction. Pertrochanteric fractures occurred more frequently (81.5%); the patients' age was higher (80 years on the average) and women outnumbered men at a ratio of 3:1. Intertrochanteric fractures were found in significantly younger patients (average, 72 years), with a women-to-men ratio of 1.3:1. Stable pertrochanteric fractures (31-A1) were preferably indicated for DHS surgery. Unstable pertrochanteric (31-A2) and intertrochanteric (31- A3) fractures were treated with a nail. The patients underwent surgery on the day of injury or the next day. In the case of contraindications to an urgent intervention, surgery was performed after the patient's medical condition had stabilised. The number of complications was largely related to technical errors, such as insufficient reduction or an incorrectly inserted implant. Intertrochanteric fractures were associated with a higher occurrence of complications. No implant can compensate for errors due to surgery. Serious complications can be reduced by the correct assessment of fracture type, the use of an appropriate operative technique and early treatment of potential complications. The necessity of restoring continuity in the medial cortex of the femoral neck (Adams' arch) is the requirement that should be observed. Pseudoarthrosis or varus malalignment in a healed hip should be managed by valgus osteotomy. When the femoral head or the acetabulum is damaged, total hip arthroplasty is indicated. A prerequisite for successful surgical outcome is urgently and correctly performed osteosynthesis allowing for early rehabilitation and mobilisation of the patient.

  15. The limited anterior approach of the elbow for open reduction and internal fixation of capitellum fractures. Surgical technique and clinical experience in 2 cases with more than 2 years follow-up.

    Science.gov (United States)

    Ballesteros-Betancourt, J R; Fernández-Valencia, J A; García-Tarriño, R; Domingo-Trepat, A; Sastre-Solsona, S; Combalia-Aleu, A; Llusá-Pérez, M

    Fractures involving the capitellum can be treated surgically by excision of the fragment, or by reduction and internal fixation with screws, with or without heads. The lateral Kocher approach is the most common approach for open reduction. We believe that the limited anterior approach of the elbow, could be a valid technique for treating these fractures, as it does not involve the detachment of any muscle group or ligament, facilitating the recovery process. A description is presented of the surgical technique, as well as of 2cases with a Bryan-Morrey type 1 fracture (Dubberley type 1A). Two different final quality of life evaluation questionnaires were completed by telephone: the EuroQol Five Dimensions Questionnaire (EQ-5D), and the patient part of the Liverpool Elbow Score (PAQ-LES) questionnaire. The 2patients showed favourable clinical progress at 36 and 24 months, respectively, with an extension/flexion movement arc of -5°/145° and -10°/145°, as well as a pronosupination of 85°/80° and 90°/90°. The 2patients showed radiological consolidation with no signs of osteonecrosis. The EQ-5D score was 0.857 and 0.910 (range: 0.36-1), and a PAQ-SLE of 35 and 35 (range: 17-36), respectively. We believe that the limited anterior approach of the elbow is a technical option to consider for the open surgical treatment of a capitellum fracture, although further studies are needed to demonstrate its superiority and clinical safety compared to the classical lateral Kocher approach. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. On the charge radius of the neutrino

    CERN Document Server

    Bernabeu, J; Papavassiliou, J; Vidal, J

    2000-01-01

    Using the pinch technique we construct at one-loop order a neutrino charge radius, which is finite, depends neither on the gauge-fixing parameter nor on the gauge-fixing scheme employed, and is process-independent. This definition stems solely from an effective proper photon-neutrino one-loop vertex, with no reference to box or self-energy contributions. The role of the $WW$ box in this construction is critically examined. In particular it is shown that the exclusion of the effective WW box from the definition of the neutrino charge radius is not a matter of convention but is in fact dynamically realized when the target-fermions are right-handedly polarized. In this way we obtain a unique decomposition of effective self-energies, vertices, and boxes, which separately respect electroweak gauge invariance. We elaborate on the tree-level origin of the mechanism which enforces at one-loop level massive cancellations among the longitudinal momenta appearing in the Feynman diagrams, and in particular those associat...

  17. Nuclear charge radius of {sup 11}Li

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Rodolfo, E-mail: R.Sanchez@GSI.de; Noertershaeuser, Wilfried [Gesellschaft fuer Schwerionenforschung (Germany); Dax, Andreas [CERN(Switzerland); Ewald, Guido; Goette, Stefan; Kirchner, Reinhard; Kluge, H.-Juergen; Kuehl, Thomas [Gesellschaft fuer Schwerionenforschung (Germany); Wojtaszek, Agnieszka [Swietokrzyska Academy, Institute of Physics (Poland); Bushaw, Bruce A. [Pacific Northwest National Laboratory (United States); Drake, Gordon W. F. [University of Windsor, Department of Physics (Canada); Yan Zongchao [University of New Brunswick, Department of Physics (Canada); Zimmermann, Claus [Physikalisches Institut, Eberhard Karls Universitaet Tuebingen (Germany); Albers, Daniel; Behr, John; Bricault, Pierre; Dilling, Jens; Dombsky, Marik; Lassen, Jens; Phil Levy, C. D. [Tri-University Meson Facility (Canada)

    2006-07-15

    We have determined the nuclear charge radius of {sup 11}Li by high-precision laser spectroscopy. The experiment was performed at the TRIUMF-ISAC facility where the {sup 7}Li-{sup 11}Li isotope shift (IS) was measured in the 2s{yields}3s electronic transition using Doppler-free two-photon spectroscopy with a relative accuracy better than 10{sup -5}. The accuracy for the IS of the other lithium isotopes was also improved. IS's are mainly caused by differences in nuclear mass, but changes in proton distribution also give small contributions. Comparing experimentally measured IS with advanced atomic calculation of purely mass-based shifts, including QED and relativistic effects, allows derivation of the nuclear charge radii. The radii are found to decrease monotonically from {sup 6}Li to {sup 9}Li, and then increase with {sup 11}Li about 11% larger than {sup 9}Li. These results are a benchmark for the open question as to whether nuclear core excitation by halo neutrons is necessary to explain the large nuclear matter radius of {sup 11}Li; thus, the results are compared with a number of nuclear structure models.

  18. Nuclear charge radius of 11Li

    International Nuclear Information System (INIS)

    Sanchez, Rodolfo; Noertershaeuser, Wilfried; Dax, Andreas; Ewald, Guido; Goette, Stefan; Kirchner, Reinhard; Kluge, H.-Juergen; Kuehl, Thomas; Wojtaszek, Agnieszka; Bushaw, Bruce A.; Drake, Gordon W. F.; Yan Zongchao; Zimmermann, Claus; Albers, Daniel; Behr, John; Bricault, Pierre; Dilling, Jens; Dombsky, Marik; Lassen, Jens; Phil Levy, C. D.

    2006-01-01

    We have determined the nuclear charge radius of 11 Li by high-precision laser spectroscopy. The experiment was performed at the TRIUMF-ISAC facility where the 7 Li- 11 Li isotope shift (IS) was measured in the 2s → 3s electronic transition using Doppler-free two-photon spectroscopy with a relative accuracy better than 10 -5 . The accuracy for the IS of the other lithium isotopes was also improved. IS's are mainly caused by differences in nuclear mass, but changes in proton distribution also give small contributions. Comparing experimentally measured IS with advanced atomic calculation of purely mass-based shifts, including QED and relativistic effects, allows derivation of the nuclear charge radii. The radii are found to decrease monotonically from 6 Li to 9 Li, and then increase with 11 Li about 11% larger than 9 Li. These results are a benchmark for the open question as to whether nuclear core excitation by halo neutrons is necessary to explain the large nuclear matter radius of 11 Li; thus, the results are compared with a number of nuclear structure models.

  19. QED confronts the radius of the proton

    CERN Document Server

    De Rujula, A

    2011-01-01

    Recent results on muonic hydrogen [1] and the ones compiled by CODATA on ordinary hydrogen and $ep$-scattering [2] are $5\\sigma$ away from each other. Two reasons justify a further look at this subject: 1) One of the approximations used in [1] is not valid for muonic hydrogen. This amounts to a shift of the proton's radius by $\\sim 3$ of the standard deviations of [1], in the "right" direction of data-reconciliation. In field-theory terms, the error is a mismatch of renormalization scales. Once corrected, the proton radius "runs", much as the QCD coupling "constant" does. 2) The result of [1] requires a choice of the "third Zemach moment". Its published independent determination is based on an analysis with a $p$-value --the probability of obtaining data with equal or lesser agreement with the adopted (fit form-factor) hypothesis-- of $3.92\\times 10^{-12}$. In this sense, this quantity is not empirically known. Its value would regulate the level of "tension" between muonic- and ordinary-hydrogen results, curr...

  20. Contemporary management of subtrochanteric fractures.

    Science.gov (United States)

    Joglekar, Siddharth B; Lindvall, Eric M; Martirosian, Armen

    2015-01-01

    Cephalomedullary interlocking nails that allow for trochanteric entry and minimally invasive fixation have revolutionized the contemporary management of subtrochanteric fractures with improved union rates and decreased incidence of fixation failure. The most successful alternative to intramedullary fixation remains the angled blade plate. Despite biomechanical superiority of contemporary intramedullary implants to previous intramedullary devices, the importance of achieving and maintaining satisfactory fracture reduction prior to and during hardware insertion cannot be overemphasized. In comminuted and more challenging fractures, additional techniques, such as limited open reduction with clamps and/or cables, can allow for canal restoration and more anatomic reductions prior to and/or during nail insertion. Published by Elsevier Inc.

  1. Overview of Mandibular Condyle Fracture

    OpenAIRE

    Park, Su-Seong; Lee, Keun-Cheol; Kim, Seok-Kwun

    2012-01-01

    The mandibular condyle is a region that plays a key role in the opening and closing of the mouth, and because fracture causes functional and aesthetic problems such as facial asymmetry, it is very important to perform accurate reduction. Traditionally, there has been disagreement on how to manage fracture of the mandibular condyle. This review explores the misunderstanding of mandibular condyle fracture treatment and modern-day treatment strategies.

  2. Overview of Mandibular Condyle Fracture

    Directory of Open Access Journals (Sweden)

    Su-Seong Park

    2012-07-01

    Full Text Available The mandibular condyle is a region that plays a key role in the opening and closing of the mouth, and because fracture causes functional and aesthetic problems such as facial asymmetry, it is very important to perform accurate reduction. Traditionally, there has been disagreement on how to manage fracture of the mandibular condyle. This review explores the misunderstanding of mandibular condyle fracture treatment and modern-day treatment strategies.

  3. Overview of Mandibular Condyle Fracture

    Directory of Open Access Journals (Sweden)

    Su-Seong Park

    2012-07-01

    Full Text Available The mandibular condyle is a region that plays a key role in the opening and closing ofthe mouth, and because fracture causes functional and aesthetic problems such as facialasymmetry, it is very important to perform accurate reduction. Traditionally, there has beendisagreement on how to manage fracture of the mandibular condyle. This review exploresthe misunderstanding of mandibular condyle fracture treatment and modern-day treatmentstrategies.

  4. Finite Larmor radius stabilization of ballooning modes in tokamaks

    International Nuclear Information System (INIS)

    Tsang, K.T.

    1980-07-01

    A ballooning mode equation that includes full finite Larmor radius effects has been derived from the Vlasov equation for a circular tokamak equilibrium. Numerical solution of this equation shows that finite Larmor radius effects are stabilizing

  5. Rib Fractures

    Science.gov (United States)

    ... Video) Achilles Tendon Tear Additional Content Medical News Rib Fractures By Thomas G. Weiser, MD, MPH, Associate Professor, ... Tamponade Hemothorax Injury to the Aorta Pulmonary Contusion Rib Fractures Tension Pneumothorax Traumatic Pneumothorax (See also Introduction to ...

  6. Root fractures

    DEFF Research Database (Denmark)

    Andreasen, Jens Ove; Christensen, Søren Steno Ahrensburg; Tsilingaridis, Georgios

    2012-01-01

    The purpose of this study was to analyze tooth loss after root fractures and to assess the influence of the type of healing and the location of the root fracture. Furthermore, the actual cause of tooth loss was analyzed....

  7. Calculation of nuclear radius using alpha decay

    International Nuclear Information System (INIS)

    Castro, R.B. de.

    1988-01-01

    Using a Quantum Theory approach for the Alpha-Decay process, a formula is deduced for determination of the nuclear radius of the s-state, that is, a nuclear model with a spherical shell. The hypothesis that it is possible to individualize the alpha particle and the daughter nucleus at the moment of the alpha particle emission is considered. In considered in these conditions, the treatment of a two body problem considered as point particles, repelling each other by Coulomb's Law. Using the new values of the fundamental physical constants, experimentally determinated, by substitution of their numerical values in the proposed, new values of nuclear radii are obtained. These values are compared with those found in the literature. (author) [pt

  8. Research of Precataclysmic Variables with Radius Excesses

    Science.gov (United States)

    Deminova, N. R.; Shimansky, V. V.; Borisov, N. V.; Gabdeev, M. M.; Shimanskaya, N. N.

    2017-06-01

    The results of spectroscopic observations of the pre-cataclysmic variable NSVS 14256825, which is a HW Vir binary system, were analyzed. The chemical composition is determined, the radial velocities and equivalent widths of a given star are measured. The fundamental parameters of the components were determined (R1 = 0.166 R⊙ , M2 = 0.100 M⊙ , R2 = 0.122 R⊙). It is shown that the secondary component has a mass close to the mass of brown dwarfs. A comparison of two close binary systems is made: HS 2333 + 3927 and NSVS 14256825. A radius-to-mass relationship for the secondary components of the studied pre-cataclysmic variables is constructed. It is concluded that an excess of radii relative to model predictions for MS stars is observed in virtually all systems.

  9. Understanding the mass-radius relation for sub-Neptunes: radius as a proxy for composition

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Eric D.; Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States)

    2014-09-01

    Transiting planet surveys like Kepler have provided a wealth of information on the distribution of planetary radii, particularly for the new populations of super-Earth- and sub-Neptune-sized planets. In order to aid in the physical interpretation of these radii, we compute model radii for low-mass rocky planets with hydrogen-helium envelopes. We provide model radii for planets 1-20 M {sub ⊕}, with envelope fractions 0.01%-20%, levels of irradiation 0.1-1000 times Earth's, and ages from 100 Myr to 10 Gyr. In addition we provide simple analytic fits that summarize how radius depends on each of these parameters. Most importantly, we show that at fixed H/He envelope fraction, radii show little dependence on mass for planets with more than ∼1% of their mass in their envelope. Consequently, planetary radius is to a first order a proxy for planetary composition, i.e., H/He envelope fraction, for Neptune- and sub-Neptune-sized planets. We recast the observed mass-radius relationship as a mass-composition relationship and discuss it in light of traditional core accretion theory. We discuss the transition from rocky super-Earths to sub-Neptune planets with large volatile envelopes. We suggest ∼1.75 R {sub ⊕} as a physically motivated dividing line between these two populations of planets. Finally, we discuss these results in light of the observed radius occurrence distribution found by Kepler.

  10. Two-stage open reduction and internal fixation versus limited internal fixation combined with external fixation: a meta-analysis of postoperative complications in patients with severe Pilon fractures.

    Science.gov (United States)

    Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He

    2018-01-01

    Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.

  11. Evaluation of scale effects on hydraulic characteristics of fractured rock using fracture network model

    International Nuclear Information System (INIS)

    Ijiri, Yuji; Sawada, Atsushi; Uchida, Masahiro; Ishiguro, Katsuhiko; Umeki, Hiroyuki; Sakamoto, Kazuhiko; Ohnishi, Yuzo

    2001-01-01

    It is important to take into account scale effects on fracture geometry if the modeling scale is much larger than the in-situ observation scale. The scale effect on fracture trace length, which is the most scale dependent parameter, is investigated using fracture maps obtained at various scales in tunnel and dam sites. We found that the distribution of fracture trace length follows negative power law distribution in regardless of locations and rock types. The hydraulic characteristics of fractured rock is also investigated by numerical analysis of discrete fracture network (DFN) model where power law distribution of fracture radius is adopted. We found that as the exponent of power law distribution become larger, the hydraulic conductivity of DFN model increases and the travel time in DFN model decreases. (author)

  12. Stress Fractures

    Science.gov (United States)

    Stress fractures Overview Stress fractures are tiny cracks in a bone. They're caused by repetitive force, often from overuse — such as repeatedly jumping up and down or running long distances. Stress fractures can also arise from normal use of ...

  13. Reduction of diuretics and analysis of water and muscle volumes to prevent falls and fall-related fractures in older adults.

    Science.gov (United States)

    Okada, Kosuke; Okada, Masahiro; Kamada, Nanao; Yamaguchi, Yumiko; Kakehashi, Masayuki; Sasaki, Hidemi; Katoh, Shigeko; Morita, Katsuya

    2017-02-01

    In an attempt to decrease the incidence of falls and fall-related fractures at a special geriatric nursing home, we endeavored to reduce diuretic doses, and examined the relationship between the effectiveness of this approach with the body compositions and activities of daily living of the study cohort. We enrolled 93 participants living in the community, 60 residents of an intermediate geriatric nursing home and 50 residents of the 100-bed Kandayama Yasuragien special geriatric nursing home. We recorded body composition using a multifrequency bioelectrical impedance analyzer. Daily loop diuretic and other diuretic regimens of those in the special geriatric nursing home were reduced or replaced with "NY-mode" diuretic therapy, namely, spironolactone 12.5 mg orally once on alternate days. The incidence of falls fell from 53 in 2011 to 29 in 2012, and there were no fall-related proximal femoral fractures for 3 years after the introduction of NY-mode diuretic therapy. We also found statistically significant differences in muscle and intracellular water volumes in our elderly participants: those with higher care requirements or lower levels of independence had lower muscle or water volumes. We found that reducing or replacing daily diuretics with NY-mode therapy appeared to reduce the incidence of falls and fall-related proximal femoral fracture, likely by preserving intracellular and extracellular body water volumes. Low-dose spironolactone (12.5 mg on alternate days) appears to be an effective means of treating elderly individuals with chronic heart failure or other edematous states, while preventing falls and fall-related fractures. Geriatr Gerontol Int 2017; 17: 262-269. © 2016 The Authors. Geriatrics & Gerontology International published by John Wiley & Sons Australia, Ltd on behalf of Japan Geriatrics Society.

  14. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    Science.gov (United States)

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  15. Rehabilitation after falls and fractures.

    Science.gov (United States)

    Dionyssiotis, Y; Dontas, I A; Economopoulos, D; Lyritis, G P

    2008-01-01

    Falls are one of the most common geriatric problems threatening the independence of older persons. Elderly patients tend to fall more often and have a greater tendency to fracture their bones. Fractures occur particularly in osteoporotic people due to increased bone fragility, resulting in considerable reduction of quality of life, morbidity, and mortality. This article provides information for the rehabilitation of osteoporotic fractures pertaining to the rehabilitation of the fractured patient, based on personal experience and literature. It also outlines a suggested effective and efficient clinical strategy approach for preventing falls in individual patients.

  16. Experimental study of finite Larmor radius effects

    International Nuclear Information System (INIS)

    Struve, K.W.

    1980-08-01

    Linear Z-pinches in Ar, Kr, Xe, N 2 , and He are experimentally studied in regimes where strong finite Larmor radius effects could provide a significant stabilizing effect. Scaling arguments show that for deuterium such a pinch has an electron line density of order 2 x 10 15 /cm. For higher Z plasmas a higher line density is allowed, the exact value of which depends on the average ion charge. The pinch is formed by puffing gas axially through the cathode towards the anode of an evacuated pinch chamber. When the gas reaches the anode, the pinch bank is fired. The pinch current rises in 2 to 3 μsec to a maximum of 100 to 200 kA. The pinch bank capacitance is 900 μF, and the external inductance is 100 nH. Additionally, the bank is fused to increase dI/dt. The primary diagnostics are a framing camera, a spatially resolved Mach-Zehnder interferometer, and X-ray absorption

  17. Allogenic bone rods with freeze drying and gamma rays irradiation for treatment of fracture

    International Nuclear Information System (INIS)

    Zhou Zhenbin

    1999-01-01

    Opened reduction and internal fixation are the usual treatment of fracture, but both methods need a second operation for removal implants. The benefits of the bone rods are that they can avoid the removement of internal fixation and will be absorbed spontaneously. The bone rods are made of allogeneic compact bones with freeze-drying and gamma rays irradiation supplied by Shanxi Provincial Tissue Bank. The purpose of this study is to evaluate allograft reaction, the stability of the internal fixation, osteoinduction in the treatment of fracture using allogeneic bone rods with freeze drying and gamma rays irradiation. From May 1997 to May 1998, fourteen cases (male 12, female 2) of treatment were reviewed. The mean age was 37.3 (21-5 1). There were 3 medial malleolus fractures, 7 tibia and fibula fractures, 1 ulna and radius fracture, 1 lateral condyle of humerus fracture. The clinical results were satisfactory. Because the strength of the bone rods are weaker than that of screws, the bone rods are only indicated in the fixation of cancellous bones fracture and unloaded bone fracture. It can be used as a supplementary fixation of loaded bone. It is not indicated for fixation of comminuted fracture. More than two bone rods may be used in the fixation of fracture in order to get stability of the fracture and decrease stress between rods which will prevent the break of the bone rods. Allogeneic bone rods with freeze-drying and gamma rays irradiation can be used as implants of non-immunogenicity. There are no allograft reactions in all cases (including fever, leukocytosis, exudation or swelling in the wound). Although plenty of experimental studies have showed that freeze drying with gamma rays irradiation (below 50 KGy) would not destroy BMP of bone allograft, but there is no osteoinduction in our cases. The healing of a fracture and bridging external callus are similar as other operations. This new technique may have the following advantages compare with the screws: 1

  18. Changing incidence and residual lifetime risk of common osteoporosis-related fractures

    DEFF Research Database (Denmark)

    Lauritzen, J B; Schwarz, Peter; Lund, B

    1993-01-01

    1735 fractures of the distal radius, 747 fractures of the proximal humerus, 878 cervical and 635 trochanteric hip fractures were included. In men 273 cervical and 232 trochanteric hip fractures were included. The fractures were registered during the period 1976 to 1984 and changes in age.......05) during the observation period, while no significant decrease was found in the incidence of trochanteric fractures. No significant changes in incidence were observed in women with radial or humeral fractures, or in men with hip fractures. A women 60 years old with a life expectancy of 81 years had......Changes in incidence and lifetime risk of fractures are of major importance in the epidemiology of osteoporosis. We focused on hip fractures in women and men and on radial and humeral fractures in women. The study subjects comprised 4500 women and men 20 years old or more with fractures. In women...

  19. Simulation of complex fracture networks influenced by natural fractures in shale gas reservoir

    Directory of Open Access Journals (Sweden)

    Zhao Jinzhou

    2014-10-01

    Full Text Available When hydraulic fractures intersect with natural fractures, the geometry and complexity of a fracture network are determined by the initiation and propagation pattern which is affected by a number of factors. Based on the fracture mechanics, the criterion for initiation and propagation of a fracture was introduced to analyze the tendency of a propagating angle and factors affecting propagating pressure. On this basis, a mathematic model with a complex fracture network was established to investigate how the fracture network form changes with different parameters, including rock mechanics, in-situ stress distribution, fracture properties, and frac treatment parameters. The solving process of this model was accelerated by classifying the calculation nodes on the extending direction of the fracture by equal pressure gradients, and solving the geometrical parameters prior to the iteration fitting flow distribution. With the initiation and propagation criterion as the bases for the propagation of branch fractures, this method decreased the iteration times through eliminating the fitting of the fracture length in conventional 3D fracture simulation. The simulation results indicated that the formation with abundant natural fractures and smaller in-situ stress difference is sufficient conditions for fracture network development. If the pressure in the hydraulic fractures can be kept at a high level by temporary sealing or diversion, the branch fractures will propagate further with minor curvature radius, thus enlarging the reservoir stimulation area. The simulated shape of fracture network can be well matched with the field microseismic mapping in data point range and distribution density, validating the accuracy of this model.

  20. Comminuted Distal Radial Fracture with Large Rotated Palmar Medial Osteochondral Fragment in the Joint.

    Science.gov (United States)

    Gökkus, Kemal; Sagtas, Ergin; Kesgin, Engin; Aydin, Ahmet Turan

    2018-01-01

    Intra-articular distal radius fractures have long been massively discussed in the literature, but regarding to fractures that possess rotated volar medial fragment in the joint a few amount papers has been written. In this article, we would like to emphasize the significance of the rotated palmar medial (lunate facet) fragment. A 39-year-old man fell from a height of about 3 m and landed on his right outstretched hand; within 40 min, he arrived at our clinic presenting with a severe pain and swelling in his right wrist. Initial X-rays of the wrist revealed dorsal subluxation of the radiocarpal joint with dorsal comminution of the radial articular surface and fracture of the radial styloid process, with (nearly inverted) ~ 140-150° rotation of the palmar medial fragment. With an additional volar approach, the fragment reduced and stabilized with two K-wires and wrist immobilized in external fixator. The patient returned to daily activities without any discomfort and pain after the 1 year from the surgery. Overlooking of palmar rotated osteochondral fragment will cause deficiency to build proper pre-operative strategy to approach the reduction of the fragment. The incompetence of reduction will deteriorate the articular surface and lead to early osteoarthritis of the wrist. The surgeon should detect this fragment and should be familiar with volar approaches of the wrist. Above average surgical experience would be needed for successful reduction.

  1. An iterative algorithm for calculating stylus radius unambiguously

    International Nuclear Information System (INIS)

    Vorburger, T V; Zheng, A; Renegar, T B; Song, J-F; Ma, L

    2011-01-01

    The stylus radius is an important specification for stylus instruments and is commonly provided by instrument manufacturers. However, it is difficult to measure the stylus radius unambiguously. Accurate profiles of the stylus tip may be obtained by profiling over an object sharper than itself, such as a razor blade. However, the stylus profile thus obtained is a partial arc, and unless the shape of the stylus tip is a perfect sphere or circle, the effective value of the radius depends on the length of the tip profile over which the radius is determined. We have developed an iterative, least squares algorithm aimed to determine the effective least squares stylus radius unambiguously. So far, the algorithm converges to reasonable results for the least squares stylus radius. We suggest that the algorithm be considered for adoption in documentary standards describing the properties of stylus instruments.

  2. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  3. Finite-Larmor-radius stability theory of EBT plasmas

    International Nuclear Information System (INIS)

    Berk, H.L.; Cheng, C.Z.; Rosenbluth, M.N.; Van Dam, J.W.

    1982-11-01

    An eikonal ballooning-mode formalism is developed to describe curvature-driven modes of hot electron plasmas in bumpy tori. The formalism treats frequencies comparable to the ion-cyclotron frequency, as well as arbitrary finite Larmor radius and field polarization, although the detailed analysis is restricted to E/sub parallel/ = 0. Moderate hot-electron finite-Larmor-radius effects are found to lower the background beta core limit, whereas strong finite-Lamor-radius effects produce stabilization

  4. Numerical Analysis of AHSS Fracture in a Stretch-bending Test

    Science.gov (United States)

    Luo, Meng; Chen, Xiaoming; Shi, Ming F.; Shih, Hua-Chu

    2010-06-01

    Advanced High Strength Steels (AHSS) are increasingly used in the automotive industry due to their superior strength and substantial weight reduction advantage. However, their limited ductility gives rise to numerous manufacturing issues. One of them is the so-called `shear fracture' often observed on tight radii during stamping processes. Since traditional approaches, such as the Forming Limit Diagram (FLD), are unable to predict this type of fracture, efforts have been made to develop failure criteria that can predict shear fractures. In this paper, a recently developed Modified Mohr-Coulomb (MMC) ductile fracture criterion[1] is adopted to analyze the failure behavior of a Dual Phase (DP) steel sheet during stretch bending operations. The plasticity and ductile fracture of the present sheet are fully characterized by the Hill'48 orthotropic model and the MMC fracture model respectively. Finite Element models with three different element types (3D, shell and plane strain) were built for a Stretch Forming Simulator (SFS) test and numerical simulations with four different R/t ratios (die radius normalized by sheet thickness) were performed. It has been shown that the 3D and shell element models can accurately predict the failure location/mode, the upper die load-displacement responses as well as the wall stress and wrap angle at the onset of fracture for all R/t ratios. Furthermore, a series of parametric studies were conducted on the 3D element model, and the effects of tension level (clamping distance) and tooling friction on the failure modes/locations were investigated.

  5. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    Directory of Open Access Journals (Sweden)

    Tabet A. Al-Sadek

    2016-11-01

    Full Text Available BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with

  6. Development of stress-modified fracture strain criterion for ductile fracture of API X65 steel

    International Nuclear Information System (INIS)

    Oh, Chang Kyun; Kim, Yun Jae; Park, Jin Moo; Kim, Woo Sik; Baek, Jong Hyun

    2005-01-01

    This paper presents a stress-modified fracture strain for API X65 steel used for gas pipeline, as a function of stress triaxiality. To determine the stress-modified fracture strain, tension test of bars with four different notch radii, made of API X65 steel, is firstly performed, from which true fracture strains are determined as a function of notch radius. Then detailed elastic-plastic, large strain Finite Element (FE) analyses are performed to estimate variations of stress triaxiality in the notched bars with load. Combining experimental with FE results provides the true fracture strain as a function of stress triaxiality, which is regarded as a criterion of ductile fracture. Application of the developed stress-modified fracture strain to failure prediction of gas pipes made of API X65 steel with various types of defects is discussed

  7. Mode II brittle fracture: recent developments

    Directory of Open Access Journals (Sweden)

    A. Campagnolo

    2017-10-01

    Full Text Available Fracture behaviour of V-notched specimens is assessed using two energy based criteria namely the averaged strain energy density (SED and Finite Fracture Mechanics (FFM. Two different formulations of FFM criterion are considered for fracture analysis. A new formulation for calculation of the control radius Rc under pure Mode II loading is presented and used for prediction of fracture behaviour. The critical Notch Stress Intensity Factor (NSIF at failure under Mode II loading condition can be expressed as a function of notch opening angle. Different formulations of NSIFs are derived using the three criteria and the results are compared in the case of sharp V-notched brittle components under in-plane shear loading, in order to investigate the ability of each method for the fracture assessment. For this purpose, a bulk of experimental data taken from the literature is employed for the comparison among the mentioned criteria

  8. The effects of a Pilates-based exercise rehabilitation program on functional outcome and fall risk reduction in an aging adult status-post traumatic hip fracture due to a fall.

    Science.gov (United States)

    Stivala, Adam; Hartley, Greg

    2014-01-01

    Currently, little information describing the relationship of Pilates-based strength and stability exercises with fall risk in the geriatric population exists. The purpose of this report was to examine the impact of a Pilates-based rehabilitation (PBR) program on reducing fall risk in an aging adult status postfall with resulting hip fracture and open reduction and internal fixation. The patient was an 84-year-old woman admitted to a skilled nursing facility (SNF) after a right hip fracture resulting from a fall at home. The patient's relevant medical history included frequent falls due to loss of balance, a previous left hip fracture with resultant arthroplasty, and a stroke roughly 20 years prior. The patient received physical therapy and occupational therapy 6 days per week for 26 days in an SNF. The physical therapy intervention consisted of gait and transfer training, neuromuscular reeducation, and an adjunct of specialized PBR exercises for the following impairments: decreased core strength and awareness and poor dynamic stabilization during functional activities. The patient demonstrated increases in lower extremity strength and active range of motion, ambulation distance and speed, and transfer ability. The patient was able to return home and live with her husband while requiring only incidental assistance with activities of daily living. She was able to independently ambulate around her home with her rolling walker. Her fall risk was also reduced from initial evaluation based on several fall risk assessments, including the Four Square Step Test, the Berg Balance Scale, and the Timed Up and Go. This case illustrates the benefit of integrating PBR exercises into a standard SNF rehabilitation program, which may contribute to decreased fall risk.

  9. Facial Fractures.

    Science.gov (United States)

    Ghosh, Rajarshi; Gopalkrishnan, Kulandaswamy

    2018-06-01

    The aim of this study is to retrospectively analyze the incidence of facial fractures along with age, gender predilection, etiology, commonest site, associated dental injuries, and any complications of patients operated in Craniofacial Unit of SDM College of Dental Sciences and Hospital. This retrospective study was conducted at the Department of OMFS, SDM College of Dental Sciences, Dharwad from January 2003 to December 2013. Data were recorded for the cause of injury, age and gender distribution, frequency and type of injury, localization and frequency of soft tissue injuries, dentoalveolar trauma, facial bone fractures, complications, concomitant injuries, and different treatment protocols.All the data were analyzed using statistical analysis that is chi-squared test. A total of 1146 patients reported at our unit with facial fractures during these 10 years. Males accounted for a higher frequency of facial fractures (88.8%). Mandible was the commonest bone to be fractured among all the facial bones (71.2%). Maxillary central incisors were the most common teeth to be injured (33.8%) and avulsion was the most common type of injury (44.6%). Commonest postoperative complication was plate infection (11%) leading to plate removal. Other injuries associated with facial fractures were rib fractures, head injuries, upper and lower limb fractures, etc., among these rib fractures were seen most frequently (21.6%). This study was performed to compare the different etiologic factors leading to diverse facial fracture patterns. By statistical analysis of this record the authors come to know about the relationship of facial fractures with gender, age, associated comorbidities, etc.

  10. Does osteoporosis increase complication risk in surgical fracture treatment? A protocol combining new endpoints for two prospective multicentre open cohort studies

    Directory of Open Access Journals (Sweden)

    Marent Marta

    2010-11-01

    Full Text Available Abstract Background With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation. Methods/Design The studies were planned using a prospective multicentre open cohort design and included patients between 50 and 90 years of age. Distal radius and proximal humerus fractures were treated with locking compression 2.4 mm and proximal humerus internal locking plates, respectively. Follow-up examinations were planned for 6 weeks, 3 and 12 months as well as a telephone interview at 6 months. The primary outcome focuses on the occurrence of at least one local bone quality related complication. Local bone quality is determined by measuring bone mineral density and bone mineral content at the contralateral radius. Primary complications are categorised according to predefined factors directly related to the bone/fracture or the implant/surgical technique. Secondary outcomes include the documentation of soft tissue/wound or general/systemic complications, clinical assessment of range of motion, and patient-rated evaluations of upper limb function and quality of life using both objective and subjective measures. Discussion The prospective multicentre open cohort studies will determine the value of local bone quality as measured by bone mineral density and content, and compare the quality of local bone of patients who experience a complication (cases following surgery with that of patients who do not (controls. These measurements are novel and

  11. Fracture sacrum.

    Directory of Open Access Journals (Sweden)

    Dogra A

    1995-04-01

    Full Text Available An extremely rare case of combined transverse and vertical fracture of sacrum with neurological deficit is reported here with a six month follow-up. The patient also had an L1 compression fracture. The patient has recovered significantly with conservative management.

  12. Fracture Mechanics

    CERN Document Server

    Zehnder, Alan T

    2012-01-01

    Fracture mechanics is a vast and growing field. This book develops the basic elements needed for both fracture research and engineering practice. The emphasis is on continuum mechanics models for energy flows and crack-tip stress- and deformation fields in elastic and elastic-plastic materials. In addition to a brief discussion of computational fracture methods, the text includes practical sections on fracture criteria, fracture toughness testing, and methods for measuring stress intensity factors and energy release rates. Class-tested at Cornell, this book is designed for students, researchers and practitioners interested in understanding and contributing to a diverse and vital field of knowledge. Alan Zehnder joined the faculty at Cornell University in 1988. Since then he has served in a number of leadership roles including Chair of the Department of Theoretical and Applied Mechanics, and Director of the Sibley School of Mechanical and Aerospace Engineering.  He teaches applied mechanics and his research t...

  13. Uncommon Dorsal Radiocarpal Fracture Dislocation Complicated With Median Nerve Palsy: Case Report, Review of the Literature, and a New Classification System Guiding the Management

    Directory of Open Access Journals (Sweden)

    Hing-Cheong Wong

    2012-06-01

    Full Text Available We report the case of a 36-year-old lorry driver who sustained left dorsal radiocarpal fracture dislocation and left median nerve injury in a traffic accident in 2010. Emergency operation of closed reduction, cross-wrist-bridging external fixation, percutaneous transradial styloid Kirschner wire fixation, decompression of left median nerve, and repair of the partially torn palmar radiocarpal ligament were performed under general anaesthesia. Because of the persistent depressed dorsal articular rim fracture of left distal radius, another operation of open reduction, corticocancellous bone grafting, and dorsal buttress plating was performed 5 days after the initial operation. Six months after the operation, the patient enjoyed good range of wrist motion but weak twisting power, especially in supination. There was no radiological feature of radiocarpal subluxation.

  14. Numerical Radius Inequalities for Finite Sums of Operators

    Directory of Open Access Journals (Sweden)

    Mirmostafaee Alireza Kamel

    2014-12-01

    Full Text Available In this paper, we obtain some sharp inequalities for numerical radius of finite sums of operators. Moreover, we give some applications of our result in estimation of spectral radius. We also compare our results with some known results.

  15. [Distal clavicle fracture].

    Science.gov (United States)

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  16. How to evaluate the quality of fracture reduction and fixation of the wrist and ankle in clinical practice: a Delphi consensus

    NARCIS (Netherlands)

    Beerekamp, M. S.; Haverlag, R.; Ubbink, D. T.; Luitse, J. S.; Ponsen, K. J.; Goslings, J. C.

    2011-01-01

    METHOD: A Delphi study was conducted to obtain consensus on the most important criteria for the radiological evaluation of the reduction and fixation of the wrist and ankle. The Delphi study consisted of a bipartite online questionnaire, focusing on the interpretation of radiographs and CT scans of

  17. Radius Determination of Solar-type Stars Using Asteroseismology: What to Expect from the Kepler Mission

    Science.gov (United States)

    Stello, Dennis; Chaplin, William J.; Bruntt, Hans; Creevey, Orlagh L.; García-Hernández, Antonio; Monteiro, Mario J. P. F. G.; Moya, Andrés; Quirion, Pierre-Olivier; Sousa, Sergio G.; Suárez, Juan-Carlos; Appourchaux, Thierry; Arentoft, Torben; Ballot, Jerome; Bedding, Timothy R.; Christensen-Dalsgaard, Jørgen; Elsworth, Yvonne; Fletcher, Stephen T.; García, Rafael A.; Houdek, Günter; Jiménez-Reyes, Sebastian J.; Kjeldsen, Hans; New, Roger; Régulo, Clara; Salabert, David; Toutain, Thierry

    2009-08-01

    For distant stars, as observed by the NASA Kepler satellite, parallax information is currently of fairly low quality and is not complete. This limits the precision with which the absolute sizes of the stars and their potential transiting planets can be determined by traditional methods. Asteroseismology will be used to aid the radius determination of stars observed during NASA's Kepler mission. We report on the recent asteroFLAG hare-and-hounds Exercise#2, where a group of "hares" simulated data of F-K main-sequence stars that a group of "hounds" sought to analyze, aimed at determining the stellar radii. We investigated stars in the range 9 values of the artificial stars to within 3%, when the large frequency spacing is used. This is 5-10 times better than the results where seismology is not applied. These results give strong confidence that radius estimation can be performed to better than 3% for solar-like stars using automatic pipeline reduction. Even when the stellar distance and luminosity are unknown we can obtain the same level of agreement. Given the uncertainties used for this exercise we find that the input log g and parallax do not help to constrain the radius, and that T eff and metallicity are the only parameters we need in addition to the large frequency spacing. It is the uncertainty in the metallicity that dominates the uncertainty in the radius.

  18. Fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig

    2013-01-01

    Fractures of the proximal humerus have been diagnosed and managed since the earliest known surgical texts. For more than four millennia the preferred treatment was forceful traction, closed reduction, and immobilization with linen soaked in combinations of oil, honey, alum, wine, or cerate......, classification of proximal humeral fractures remains a challenge for the conduct, reporting, and interpretation of clinical trials. The evidence for the benefits of surgery in complex fractures of the proximal humerus is weak. In three systematic reviews I studied the outcome after locking plate osteosynthesis...

  19. Fracture mechanics

    CERN Document Server

    Perez, Nestor

    2017-01-01

    The second edition of this textbook includes a refined presentation of concepts in each chapter, additional examples; new problems and sections, such as conformal mapping and mechanical behavior of wood; while retaining all the features of the original book. The material included in this book is based upon the development of analytical and numerical procedures pertinent to particular fields of linear elastic fracture mechanics (LEFM) and plastic fracture mechanics (PFM), including mixed-mode-loading interaction. The mathematical approach undertaken herein is coupled with a brief review of several fracture theories available in cited references, along with many color images and figures. Dynamic fracture mechanics is included through the field of fatigue and Charpy impact testing. Explains computational and engineering approaches for solving crack-related problems using straightforward mathematics that facilitate comprehension of the physical meaning of crack growth processes; Expands computational understandin...

  20. Fracture analysis

    International Nuclear Information System (INIS)

    Ueng, Tzoushin; Towse, D.

    1991-01-01

    Fractures are not only the weak planes of a rock mass, but also the easy passages for the fluid flow. Their spacing, orientation, and aperture will affect the deformability, strength, heat transmittal, and fluid transporting properties of the rock mass. To understand the thermomechanical and hydrological behaviors of the rock surrounding the heater emplacement borehole, the location, orientation, and aperture of the fractures of the rock mass should be known. Borehole television and borescope surveys were performed to map the location, orientation, and aperture of the fractures intersecting the boreholes drilled in the Prototype Engineered Barrier System Field Tests (PEBSFT) at G-Tunnel. Core logging was also performed during drilling. However, because the core was not oriented and the depth of the fracture cannot be accurately determined, the results of the core logging were only used as reference and will not be discussed here

  1. Facial Fractures.

    Science.gov (United States)

    Ricketts, Sophie; Gill, Hameet S; Fialkov, Jeffery A; Matic, Damir B; Antonyshyn, Oleh M

    2016-02-01

    After reading this article, the participant should be able to: 1. Demonstrate an understanding of some of the changes in aspects of facial fracture management. 2. Assess a patient presenting with facial fractures. 3. Understand indications and timing of surgery. 4. Recognize exposures of the craniomaxillofacial skeleton. 5. Identify methods for repair of typical facial fracture patterns. 6. Discuss the common complications seen with facial fractures. Restoration of the facial skeleton and associated soft tissues after trauma involves accurate clinical and radiologic assessment to effectively plan a management approach for these injuries. When surgical intervention is necessary, timing, exposure, sequencing, and execution of repair are all integral to achieving the best long-term outcomes for these patients.

  2. MUSE: Measuring the proton radius with muon-proton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bernauer, Jan Christopher [Massachusetts Institute of Technology, Cambridge (United States)

    2014-07-01

    The proton radius has been measured so far using electron-proton scattering, electronic Hydrogen spectroscopy and muonic Hydrogen spectroscopy, the latter producing a much more accurate, but seven sigma different, result, leading to the now famous proton radius puzzle. The MUSE collaboration aims to complete the set of measurements by using muon scattering to determine the proton radius and to shed light on possible explanations of the discrepancy. The talk gives an overview of the experiment motivation and design and a status report on the progress.

  3. Variational principles for the spectral radius of functional operators

    International Nuclear Information System (INIS)

    Antonevich, A B; Zajkowski, K

    2006-01-01

    The spectral radius of a functional operator with positive coefficients generated by a set of maps (a dynamical system) is shown to be a logarithmically convex functional of the logarithms of the coefficients. This yields the following variational principle: the logarithm of the spectral radius is the Legendre transform of a convex functional T defined on a set of vector-valued probability measures and depending only on the original dynamical system. A combinatorial construction of the functional T by means of the random walk process corresponding to the dynamical system is presented in the subexponential case. Examples of the explicit calculation of the functional T and the spectral radius are presented.

  4. Pathological fracture in non-ossifying fibroma with histological features simulating aneurysmal bone cyst

    International Nuclear Information System (INIS)

    Hoeffel, C.; Mainard, L.; Hoeffel, J.C.; Panuel, M.; Plenat, F.

    1999-01-01

    A 12-year-old-girl presented with a fracture of an osteolytic lesion of the distal radius. A 7-year-old girl presented with a fracture of an osteolytic lesion of the femoral shaft. In both cases it was a non-ossifying fibroma with fracture misdiagnosed at pathology as aneurysmal bone cyst. Fractures through non-ossifying fibromas may alter the histological pattern of the initial lesion in two ways: firstly, by the presence of blood pigments due to the fracture, and secondly, by formation of new bone. Radiological-pathological correlation is essential to avoid histological errors after pathological fracture in a non-ossifying fibroma. (orig.)

  5. Pisiform fractures

    International Nuclear Information System (INIS)

    Fleege, M.A.; Jebson, P.J.; Renfrew, D.L.; El-Khoury, G.Y.; Steyers, C.M. Jr.

    1991-01-01

    Fractures of the pisiform are often missed due to improper radiographic evaluation and a tendency to focus on other, more obvious injuries. Delayed diagnosis may result in disabling sequelae. A high index of clinical suspicion and appropriate radiographic examination will establish the correct diagnosis. Ten patients with pisiform fracture are presented. The anatomy, mechanism of injury, clinical presentation, radiographic features, and evaluation of this injury are discussed. (orig.)

  6. Stress fractures

    International Nuclear Information System (INIS)

    Berquist, T.H.; Cooper, K.L.; Pritchard, D.J.

    1985-01-01

    The diagnosis of a stress fracture should be considered in patients presented with pain after a change in activity, especially if the activity is strenuous and the pain is in the lower extremities. Since evidence of the stress fracture may not be apparent for weeks on routine radiographs, proper use of other imaging techniques will allow an earlier diagnosis. Prompt diagnosis is especially important in the femur, where displacement may occur

  7. Pediatric facial fractures: evolving patterns of treatment.

    Science.gov (United States)

    Posnick, J C; Wells, M; Pron, G E

    1993-08-01

    This study reviews the treatment of facial trauma between October 1986 and December 1990 at a major pediatric referral center. The mechanism of injury, location and pattern of facial fractures, pattern of facial injury, soft tissue injuries, and any associated injuries to other organ systems were recorded, and fracture management and perioperative complications reviewed. The study population consisted of 137 patients who sustained 318 facial fractures. Eighty-one patients (171 fractures) were seen in the acute stage, and 56 patients (147 fractures) were seen for reconstruction of a secondary deformity. Injuries in boys were more prevalent than in girls (63% versus 37%), and the 6- to 12-year cohort made up the largest group (42%). Most fractures resulted from traffic-related accidents (50%), falls (23%), or sports-related injuries (15%). Mandibular (34%) and orbital fractures (23%) predominated; fewer midfacial fractures (7%) were sustained than would be expected in a similar adult population. Three quarters of the patients with acute fractures required operative intervention. Closed reduction techniques with maxillomandibular fixation were frequently chosen for mandibular condyle fractures and open reduction techniques (35%) for other regions of the facial skeleton. When open reduction was indicated, plate-and-screw fixation was the preferred method of stabilization (65%). The long-term effects of the injuries and the treatment given on facial growth remain undetermined. Perioperative complication rates directly related to the surgery were low.

  8. Ankle Fractures: The Operative Outcome

    Directory of Open Access Journals (Sweden)

    Ahmad Hafiz Z

    2011-03-01

    Full Text Available Ankle fractures are commonly seen in orthopaedic practice. This retrospective study of patients with ankle fractures who underwent surgical treatment in our institution from January 2000 to December 2003 was undertaken to analyze the common causes and patterns of ankle fractures; and the functional outcome of operative treatment for these fractures. Eighty patients were identified and reviewed. There were 65 male (81.3% and 15 female patients (18.7% with age ranging from 13 to 71 years old (mean, 32.3y. Common causes of ankle fractures were trauma (especially motor vehicle accidents, sports injuries and the osteoporotic bones in the elderly. Weber C (64.0% was the most common pattern of fracture at presentation. The most common operative treatment for ankle fractures was open reduction and internal fixation (73 patients, 91.2%. Excellent and good outcomes were achieved in 93.8% of cases when measured using the Olerud and Molander scoring system for foot and ankle. In conclusion, operative treatment for ankle fractures restores sufficient stability and allowed mobility of the ankle joint.

  9. A mechanical chest compressor closed-loop controller with an effective trade-off between blood flow improvement and ribs fracture reduction.

    Science.gov (United States)

    Zhang, Guang; Wu, Taihu; Song, Zhenxing; Wang, Haitao; Lu, Hengzhi; Wang, Yalin; Wang, Dan; Chen, Feng

    2015-06-01

    Chest compression (CC) is a significant emergency medical procedure for maintaining circulation during cardiac arrest. Although CC produces the necessary blood flow for patients with heart arrest, improperly deep CC will contribute significantly to the risk of chest injury. In this paper, an optimal CC closed-loop controller for a mechanical chest compressor (OCC-MCC) was developed to provide an effective trade-off between the benefit of improved blood perfusion and the risk of ribs fracture. The trade-off performance of the OCC-MCC during real automatic mechanical CCs was evaluated by comparing the OCC-MCC and the traditional mechanical CC method (TMCM) with a human circulation hardware model based on hardware simulations. A benefit factor (BF), risk factor (RF) and benefit versus risk index (BRI) were introduced in this paper for the comprehensive evaluation of risk and benefit. The OCC-MCC was developed using the LabVIEW control platform and the mechanical chest compressor (MCC) controller. PID control is also employed by MCC for effective compression depth regulation. In addition, the physiological parameters model for MCC was built based on a digital signal processor for hardware simulations. A comparison between the OCC-MCC and TMCM was then performed based on the simulation test platform which is composed of the MCC, LabVIEW control platform, physiological parameters model for MCC and the manikin. Compared with the TMCM, the OCC-MCC obtained a better trade-off and a higher BRI in seven out of a total of nine cases. With a higher mean value of cardiac output (1.35 L/min) and partial pressure of end-tidal CO2 (15.7 mmHg), the OCC-MCC obtained a larger blood flow and higher BF than TMCM (5.19 vs. 3.41) in six out of a total of nine cases. Although it is relatively difficult to maintain a stable CC depth when the chest is stiff, the OCC-MCC is still superior to the TMCM for performing safe and effective CC during CPR. The OCC-MCC is superior to the TMCM in

  10. Scaphoid Fracture

    Directory of Open Access Journals (Sweden)

    Esther Kim, BS

    2018-04-01

    Full Text Available History of present illness: A 25-year-old, right-handed male presented to the emergency department with left wrist pain after falling from a skateboard onto an outstretched hand two-weeks prior. He otherwise had no additional concerns, including no complaints of weakness or loss of sensation. On physical exam, there was tenderness to palpation within the anatomical snuff box. The neurovascular exam was intact. Plain films of the left wrist and hand were obtained. Significant findings: The anteroposterior (AP plain film of this patient demonstrates a full thickness fracture through the middle third of the scaphoid (red arrow, with some apparent displacement (yellow lines and subtle angulation of the fracture fragments (blue line. Discussion: The scaphoid bone is the most commonly fractured carpal bone accounting for 70%-80% of carpal fractures.1 Classically, it is sustained following a fall onto an outstretched hand (FOOSH. Patients should be evaluated for tenderness with palpation over the anatomical snuffbox, which has a sensitivity of 100% and specificity of 40%.2 Plain films are the initial diagnostic modality of choice and have a sensitivity of 70%, but are commonly falsely negative in the first two to six weeks of injury (false negative of 20%.3 The Mayo classification organizes scaphoid fractures as involving the proximal, mid, and distal portions of the scaphoid bone with mid-fractures being the most common.3 The proximal scaphoid is highly susceptible to vascular compromise because it depends on retrograde blood flow from the radial artery. Therefore, disruption can lead to serious sequelae including osteonecrosis, arthrosis, and functional impairment. Thus, a low threshold should be maintained for neurovascular evaluation and surgical referral. Patients with non-displaced scaphoid fractures should be placed in a thumb spica splint.3 Patients with even suspected scaphoid fractures should be placed in a thumb spica splint and re

  11. Correlation between quarter-point angle and nuclear radius

    Science.gov (United States)

    Ma, Wei-Hu; Wang, Jian-Song; Mukherjee, S.; Wang, Qi; Patel, D.; Yang, Yan-Yun; Ma, Jun-Bing; Ma, Peng; Jin, Shi-Lun; Bai, Zhen; Liu, Xing-Quan

    2017-04-01

    The correlation between quarter-point angle of elastic scattering and nuclear matter radius is studied systematically. Various phenomenological formulae with parameters for nuclear radius are adopted and compared by fitting the experimental data of quarter point angle extracted from nuclear elastic scattering reaction systems. A parameterized formula related to binding energy is recommended, which gives a good reproduction of nuclear matter radii of halo nuclei. It indicates that the quarter-point angle of elastic scattering is quite sensitive to the nuclear matter radius and can be used to extract the nuclear matter radius. Supported by National Natural Science Foundation of China (U1432247, 11575256), National Basic Research Program of China (973 Program)(2014CB845405 and 2013CB83440x) and (SM) Chinese Academy of Sciences President’s International Fellowship Initiative (2015-FX-04)

  12. Spectroscopy of muonic atoms and the proton radius puzzle

    Science.gov (United States)

    Antognini, Aldo

    2017-09-01

    We have measured several 2 S -2 P transitions in muonic hydrogen (μp), muonic deuterium (μd) and muonic helium ions (μ3He, μ4He). From muonic hydrogen we extracted a proton charge radius 20 times more precise than obtained from electron-proton scattering and hydrogen high-precision laser spectroscopy but at a variance of 7 σ from these values. This discrepancy is nowadays referred to as the proton radius puzzle. New insight has been recently provided by the first determination of the deuteron charge radius from laser spectroscopy of μd. The status of the proton charge radius puzzle including the new insights obtained by μd spectroscopy will be discussed. Work supported by the Swiss National Science Foundation SNF-200021-165854 and the ERC CoG. #725039.

  13. Human Fertility Increases with the Marital-radius

    DEFF Research Database (Denmark)

    Labouriau, Rodrigo; Amorim, António

    2008-01-01

    We report a positive association between marital radius (distance between mates' birthplaces) and fertility detected in a large population. Spurious association due to socioeconomic factors is discarded by a conditional analysis involving income, education, and urbanicity. Strong evidence...

  14. Frictional coefficient depending on active friction radius with BPV ...

    African Journals Online (AJOL)

    Frictional coefficient depending on active friction radius with BPV and BTV in automobile disc braking system. ... International Journal of Engineering, Science and Technology. Journal Home · ABOUT ... AJOL African Journals Online. HOW TO ...

  15. DML and Foil Measurements of ETA Beam Radius

    International Nuclear Information System (INIS)

    Nexsen, W; Weir, J

    2005-01-01

    Simultaneous measurements of the ETA beam radius have been made with a quartz foil and a diamagnetic loop (DML). While the measurements agreed at some settings they diverged at others. While the DML measures the rms radius of the total beam, the foil measures mainly the core and the divergence can be explained by the presence of a low density halo. Evidence of such a halo from other measurements is presented

  16. Generalized spectral radius and its max algebra version

    Czech Academy of Sciences Publication Activity Database

    Müller, Vladimír; Peperko, A.

    2013-01-01

    Roč. 439, č. 4 (2013), s. 1006-1016 ISSN 0024-3795 R&D Projects: GA ČR GA201/09/0473; GA AV ČR IAA100190903 Institutional support: RVO:67985840 Keywords : generalized spectral radius * joint spectral radius * Berger-Wang formula Subject RIV: BA - General Mathematics Impact factor: 0.983, year: 2013 http://www.sciencedirect.com/science/article/pii/S0024379512007380

  17. External fixation of tibial pilon fractures and fracture healing.

    Science.gov (United States)

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  18. Progress and prediction of occupational performance in women with distal radius fractures

    DEFF Research Database (Denmark)

    Nielsen, Tove Lise; Dekkers, Merete Klindt

    2013-01-01

    , and validated questions on pain. The number of performance problems fell from median 18 at cast removal to median 3 at 12 months. COPM performance and satisfaction scores improved significantly to 8.6 and 9.2 at 12 months. Also the DASH score improved significantly to 14.2 at 12 months. The largest improvements...

  19. Effect of physiotherapy in people with distal radius fractures: A systematic review

    Directory of Open Access Journals (Sweden)

    Claudia Liliana Moreno-Montoya

    2017-10-01

    Conclusion: Evidence suggests that supervised therapeutic interventions that include physical and exercise modalities lasting between 6 and 9 weeks, with an average of 18 sessions and three times a week, significantly improve the variables studied in patients with DRF. Future studies should establish the dose-response correlation of these interventions.

  20. Surgical approach for elastic stable intramedullary nail in pediatric radius shaft fracture

    DEFF Research Database (Denmark)

    Nørgaard, Sandra L.; Schødt Riber, Sara; Danielsson, Frederik B.

    2018-01-01

    . An electronic search of databases was performed. Titles of articles were screened, and abstracts and full text were read. Data were extracted in terms of demographics and complications. The dorsal approach had a 2.6% rate of extensor pollicis longus tendon rupture, whereas the lateral approach had a 2.9% rate...

  1. Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

    Science.gov (United States)

    de Jong, Joost J A; Lataster, Arno; van Rietbergen, Bert; Arts, Jacobus J; Geusens, Piet P; van den Bergh, Joop P W; Willems, Paul C

    2017-02-27

    Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.

  2. Post-surgical rehabilitative approach to fragility fractures.

    Science.gov (United States)

    Gimigliano, F; Iolascon, G; Riccio, I; Frizzi, L; Gimigliano, R

    2013-10-01

    Osteoporosis is a skeletal disorder characterized by compromised bone strength predisposing to an increased risk of fracture. The most frequent sites of fragility fractures are the hip, the distal radius, the spine, the proximal humerus, and the ankle. In most cases, a surgical approach with subsequent rehabilitative treatment is required. The general aims of rehabilitation are to increase functioning and improve patients' activities, participation level, and quality of life.

  3. Trochanteric fractures

    International Nuclear Information System (INIS)

    Herrlin, K.; Stroemberg, T.; Lidgren, L.; Walloee, A.; Pettersson, H.; Lund Univ.

    1988-01-01

    Four hundred and thirty trochanteric factures operated upon with McLaughlin, Ender or Richard's osteosynthesis were divided into 6 different types based on their radiographic appearance before and immediately after reposition with special reference to the medial cortical support. A significant correlation was found between the fracture type and subsequent mechanical complications where types 1 and 2 gave less, and types 4 and 5 more complications. A comparison of the various osteosyntheses showed that Richard's had significantly fewer complications than either the Ender or McLaughlin types. For Richard's osteosynthesis alone no correlation to fracture type could be made because of the small number of complications in this group. (orig.)

  4. Fracture Blisters

    Directory of Open Access Journals (Sweden)

    Uebbing, Claire M

    2011-02-01

    Full Text Available Fracture blisters are a relatively uncommon complication of fractures in locations of the body, such as the ankle, wrist elbow and foot, where skin adheres tightly to bone with little subcutaneous fat cushioning. The blister that results resembles that of a second degree burn.These blisters significantly alter treatment, making it difficult to splint or cast and often overlying ideal surgical incision sites. Review of the literature reveals no consensus on management; however, most authors agree on early treatment prior to blister formation or delay until blister resolution before attempting surgical correction or stabilization. [West J Emerg Med. 2011;12(1;131-133.

  5. [Arthroscopy-guided fracture management. Ankle joint and calcaneus].

    Science.gov (United States)

    Schoepp, C; Rixen, D

    2013-04-01

    Arthroscopic fracture management of the ankle and calcaneus requires a differentiated approach. The aim is to minimize surgical soft tissue damage and to visualize anatomical fracture reduction arthroscopically. Moreover, additional cartilage damage can be detected and treated. The arthroscopic approach is limited by deep impressions of the joint surface needing cancellous bone grafting, by multiple fracture lines on the articular side and by high-grade soft tissue damage. An alternative to the minimally invasive arthroscopic approach is open arthroscopic reduction in conventional osteosynthesis. This facilitates correct assessment of surgical reduction of complex calcaneal fractures, otherwise remaining non-anatomical reduction might not be fluoroscopically detected during surgery.

  6. The treatment of subtrochanteric fractures

    Directory of Open Access Journals (Sweden)

    Vučetić Čedomir S.

    2011-01-01

    Full Text Available Subtrochanteric fractures of the femur have a special place because of a significant number of complications following treatment. Powerful loading forces asymmetrically acting to this bone segment, as well as poor vascularization interfere with bone union. There are basically two current approaches in the fixation of subtrochanteric fractures; the first involves a plate with a compression screw and another one is intramedullary (IM nail, with two options: centromedullary (standard interlocking femoral nail and cephalomedullary femoral nail with two modifications, reconstructive and trochanteric. All IM nails may be used by open technique or closed minimal invasive method. IM nailing is favoured in view of a shorter operative time, shorter hospitalisation and complications. Indirect fracture reduction and knowledge of biology of bone fracture may result in full success without any bone graft.

  7. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  8. The creep bending of short radius pipe bends

    International Nuclear Information System (INIS)

    Spence, John

    1975-01-01

    In existing and proposed liquid metal fast breeder reactor design the pipework has considerable importance. Parts of the LMFBR include thin walled short radius bends which are expected to operate in the creep regime. In linear elasticity it is known that the assumption of long radius bends is not too severe as far as the flexibility characteristics are concerned although some modifications are necessary for accurate determination of the stresses. No data exists for nonlinear creep. Current work is aimed at elucidating the effect of the various assumptions common to linear elastic theory in so far as they affect the creep characteristics of bends on systems. Herein an energy based analysis using a simple n power constitutive law for stationary creep is employed to derive basic design data for flexibilities and stresses which will be necessary before complete systems can be assessed for creep. The analysis shows on comparison with the long radius work that the assumption of R>r is not much more restrictive in creep than for linear elasticity. Flexibilities for short radius bends appear to be well approximated by the long radius values. Thus the attractive reference stress information already derived may be used directly to find deformations without a complete knowledge of the constitutive relationship. However, stresses are somewhat different. Fortunately the maximum deviation occurs at relatively low levels of stress, the peak stresses being in fair agreement. When n=1 the present results reduce essentially to those obtained from existing linear elastic theory

  9. Fractured long bones in a term infant delivered by cesarian section

    International Nuclear Information System (INIS)

    Kaplan, M.; Dollberg, M.; Wajntraub, G.; Itzchaki, M.

    1987-01-01

    A term infant was delivered uneventfully by repeat cesarian section. At the age of 1 week there was clinical and radiographic evidence of fractures of the left tibia and right radius. The fractures most likely occurred during the cesarian section. Birth trauma should not be excluded on the basis of cesarian section delivery. (orig.)

  10. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  11. Elbow Fractures

    Science.gov (United States)

    ... is also an important factor when treating elbow fractures. Casts are used more frequently in children, as their risk of developing elbow stiffness is small; however, in an adult, elbow stiffness is much more likely. Rehabilitation directed by your doctor is often used to ...

  12. Wrist Fractures

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Wrist Fractures Email to a friend * required fields ...

  13. Shoulder Fractures

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Shoulder Fractures Email to a friend * required fields ...

  14. Isolated Fracture of the Coracoid Process

    Directory of Open Access Journals (Sweden)

    Ali Güleç

    2014-01-01

    Full Text Available Coracoid fractures are rarely seen fractures. In the shoulder girdle, coracoid process fractures generally accompany dislocation of the acromioclavicular joint or glenohumeral joint, scapula corpus, clavicula, humerus fracture, or rotator cuff tear. Coracoid fractures can be missed and the treatment for coracoid process fractures is still controversial. In this paper, a 34-year-old male manual labourer presented to the emergency department with complaints of pain and restricted movement in the left shoulder following a traffic accident. On direct radiographs and computerised tomography images a fragmented fracture was observed on the base of the coracoid process. In addition to the coracoid fracture, a mandibular fracture was determined. The patient was admitted for surgery on both fractures. After open reduction, fixation was made with a 3.5 mm cannulated screw and washer. At the postoperative 6th week, bone union was determined. The patient returned to his previous occupation pain-free and with a full range of joint movement. In conclusion, in the current case of isolated fragmented coracoid process fracture showing minimal displacement in a patient engaged in heavy manual work, surgery was preferred as it was thought that nonunion might be encountered particularly because of the effect of forces around the coracoid.

  15. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.

    Science.gov (United States)

    Langford, Joshua; Pillai, Gita; Ugliailoro, Anthony D; Yang, Edward

    2011-04-01

    This study was performed to determine the incidence of perioperative lateral wall fractures with a standard sliding hip screw (SHS) versus a percutaneous compression plate (PCCP) using identical meticulous closed reduction techniques in both groups. Retrospective analysis of a prospective trauma registry. Urban Level I trauma center. Over a 7-year period, 337 patients with intertrochanteric hip fractures were treated with either a SHS or a PCCP at our institution. The PCCP group (Group 1) consisted of 200 patients, of which 141 (71%) had adequate images to be included in the study. The SHS group (Group 2) consisted of 137 patients, of which 100 (73%) had adequate images to be included in the study. Closed reduction and plate application with either a standard sliding hip screw or a percutaneous compression plate for an Orthopaedic Trauma Association 31A1 or 31A2 intertrochanteric hip fracture. : Radiographic evidence of lateral trochanteric wall fracture as measured by intraoperative and perioperative radiographs. There was an overall lateral wall fracture incidence of 20% in the SHS group versus 1.4% in the PCCP group (P fracture types, there was a lateral wall fracture incidence of 29.8% in the SHS group versus 1.9% in the PCCP group (P trochanteric wall fracture compared with the SHS group. This difference became greater when just unstable intertrochanteric fractures were analyzed. An anatomic reduction, combined with a device (PCCP) that uses small-diameter defects in the lateral trochanteric wall, essentially eliminates perioperative lateral trochanteric wall fractures.

  16. On tidal radius determination for a globular cluster

    International Nuclear Information System (INIS)

    Ninkovic, S.

    1985-01-01

    A tidal radius determination for a globular cluster based on its density minimum, which is caused by the galactic tidal forces and derivable from a model of the Galaxy, is proposed. Results obtained on the basis of the Schmidt model for two clusters are in a satisfactory agreement with those obtained earlier by means of other methods. A mass determination for the clusters through the tidal radius, when the latter one is identified with the cluster perigalactic distance, yields unusually large mass values. Probably, the tidal radius should be identified with the instantaneous galactocentric distance. Use of models more recent than the Schmidt one indicates that a globular cluster may contain a significant portion of an invisible interstellar matter. (author)

  17. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  18. Pulsed electromagnetic field during cast immobilization in postmenopausal women with Colles’ fracture

    Directory of Open Access Journals (Sweden)

    Lazović Milica

    2012-01-01

    Full Text Available Introduction. Although Colles’ fracture i.e. a dorsally displaced distal radius fracture (DRF is one of the most common fractures, there is no enough evidence to determine the best form of rehabilitation. Objective. To assess whether the use of pulsed electromagnetic field (PEMF therapy during cast immobilization of DRF provides beneficial effects on pain, edema, wrist range of motion and function, as well as on the frequency of complications immediately after cast removal. Methods. The prospective randomized controlled study included 60 women over the age of 55 years with extra-articular displaced DRF treated with reduction and cast immobilization. The patients were alternately allocated to either a PEMF group (n=30, received 10 days of PEMF therapy during immobilization, or a control group (n=30, without PEMF therapy. Pain, function, hand circumference, wrist and forearm range of motion and frequency of complications for each patient was evaluated within two to three days of cast removal. Results. Better mean values for the majority of examined parameters were recorded in the PEMF group than in the control group, but the difference was statistically significant just for edema (p<0.001, flexion, extension and supination range (p<0.01. Conclusion. During immobilization PEMF therapy in DRF patients gave better results immediately after cast removal in terms of edema and wrist range of motion (ROM.

  19. Daily number of fractures is associated with road temperature in an urban area

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Thomsen, Morten

    2014-01-01

    winters. MATERIAL AND METHODS: Retrospective data collection was conducted on all patients treated at Bispebjerg Hospital, Denmark, for a humeral, ankle, distal radius or hip fracture during the periods October to April 2009/2010 and 2010/2011. Patients were grouped according to age into the following......,938 fractures) were treated during the study periods. The daily number of distal radius, humeral and ankle fractures increased significantly with decreasing road surface temperature and the presence of IA. For hip fractures no significant association was found. Decreasing temperature was associated......INTRODUCTION: Different factors related to winter are known to influence the fracture incidence, but little is known about the effect of road surface temperature. This study examines the association between road surface temperature and the daily number of fractures in an urban area during two...

  20. Investigation on the Productivity Behaviour in Deformable Heterogeneous Fractured Reservoirs

    DEFF Research Database (Denmark)

    Kadeethum, Teeratorn; Salimzadeh, Saeed; Nick, Hamid

    reasons for this reduction. Discrete fracture and matrix (DFM) modelling is selected in this investigation because of its ability to represent fracture behaviours more realistically. Moreover, it has become a preferential method for modelling flow in fractured formations for the past decade (Bisdom et al...

  1. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  2. Thoughts on the so-called 'radius-capitellum axis'

    International Nuclear Information System (INIS)

    Schild, H.; Mueller, H.A.; Wagner, H.; Baetz, W.; Mainz Univ.

    1982-01-01

    We have studied 438 patients radiologically in order to observe the so-called 'radius-capitellum axis'. In about a quarter of people with normal elbows the axis passes lateral to the middle portion of the capitellum, so that even when there is marked deviation, there is no certainty that the humero-radial joint is abnormal. Deviation of the axis can be caused by changes in the shape of the capitellum or of the radius, or by distension of the capsule of the elbow joint, or by various changes in muscular pull. (orig.) [de

  3. Thoughts on the so-called radius-capitellum axis

    Energy Technology Data Exchange (ETDEWEB)

    Schild, H; Mueller, H A; Wagner, H; Baetz, W

    1982-02-01

    We have studied 438 patients radiologically in order to observe the so-called 'radius-capitellum axis'. In about a quarter of people with normal elbows the axis passes lateral to the middle portion of the capitellum, so that even when there is marked deviation, there is no certainty that the humero-radial joint is abnormal. Deviation of the axis can be caused by changes in the shape of the capitellum or of the radius, or by distension of the capsule of the elbow joint, or by various changes in muscular pull.

  4. The PRad experiment and the proton radius puzzle

    Directory of Open Access Journals (Sweden)

    Gasparian Ashot

    2014-06-01

    Full Text Available New results from the recent muonic hydrogen experiments seriously questioned our knowledge of the proton charge radius, rp. The new value, with its unprecedented less than sub-percent precision, is currently up to eight standard deviation smaller than the average value from all previous experiments, triggering the well-known “proton charge radius puzzle” in nuclear and atomic physics. The PRad collaboration is currently preparing a novel, magnetic-spectrometer-free ep scattering experiment in Hall B at JLab for a new independent rp measurement to address this growing “puzzle” in physics.

  5. Underground nuclear explosions. Study of the cavity radius

    International Nuclear Information System (INIS)

    Michaud, L.

    1968-11-01

    An underground nuclear explosion creates a cavity due to the expansion of the surrounding medium vaporized by the shot. The cavity radius is related to the energy of explosion and to the overburden pressure of the medium. The introduction of new elements such as the environment of the device (in a deep hole or in a tunnel) and the cohesion of the medium leads to a relationship which determines this radius. The known French and American underground explosions performed in various media, energy and overburden conditions, satisfy this relationship with a good precision. (author) [fr

  6. Treatment of neglected femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Anil K Jain

    2015-01-01

    Full Text Available Intra-capsular femoral neck fractures are seen commonly in elderly people following a low energy trauma. Femoral neck fracture has a devastating effect on the blood supply of the femoral head, which is directly proportional to the severity of trauma and displacement of the fracture. Various authors have described a wide array of options for treatment of neglected/nonunion (NU femoral neck fracture. There is lack of consensus in general, regarding the best option. This Instructional course article is an analysis of available treatment options used for neglected femoral neck fracture in the literature and attempt to suggest treatment guides for neglected femoral neck fracture. We conducted the "Pubmed" search with the keywords "NU femoral neck fracture and/or neglected femoral neck fracture, muscle-pedicle bone graft in femoral neck fracture, fibular graft in femoral neck fracture and valgus osteotomy in femoral neck fracture." A total of 203 print articles were obtained as the search result. Thirty three articles were included in the analysis and were categorized into four subgroups based on treatment options. (a treated by muscle-pedicle bone grafting (MPBG, (b closed/open reduction internal fixation and fibular grafting (c open reduction and internal fixation with valgus osteotomy, (d miscellaneous procedures. The data was pooled from all groups for mean neglect, the type of study (prospective or retrospective, classification used, procedure performed, mean followup available, outcome, complications, and reoperation if any. The outcome of neglected femoral neck fracture depends on the duration of neglect, as the changes occurring in the fracture area and fracture fragments decides the need and type of biological stimulus required for fracture union. In stage I and stage II (Sandhu′s staging neglected femoral neck fracture osteosynthesis with open reduction and bone grafting with MPBG or Valgus Osteotomy achieves fracture union in almost 90

  7. Fracture mechanics

    International Nuclear Information System (INIS)

    Miannay, D.P.

    1995-01-01

    This book entitle ''Fracture Mechanics'', the first one of the monograph ''Materiologie'' is geared to design engineers, material engineers, non destructive inspectors and