WorldWideScience

Sample records for radionuclide imaging technologies1

  1. Radionuclide reporter gene imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Joon [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of)

    2004-04-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases.

  2. Radionuclide reporter gene imaging

    International Nuclear Information System (INIS)

    Min, Jung Joon

    2004-01-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases

  3. Nanotargeted Radionuclides for Cancer Nuclear Imaging and Internal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Gann Ting

    2010-01-01

    Full Text Available Current progress in nanomedicine has exploited the possibility of designing tumor-targeted nanocarriers being able to deliver radionuclide payloads in a site or molecular selective manner to improve the efficacy and safety of cancer imaging and therapy. Radionuclides of auger electron-, α-, β-, and γ-radiation emitters have been surface-bioconjugated or after-loaded in nanoparticles to improve the efficacy and reduce the toxicity of cancer imaging and therapy in preclinical and clinical studies. This article provides a brief overview of current status of applications, advantages, problems, up-to-date research and development, and future prospects of nanotargeted radionuclides in cancer nuclear imaging and radiotherapy. Passive and active nanotargeting delivery of radionuclides with illustrating examples for tumor imaging and therapy are reviewed and summarized. Research on combing different modes of selective delivery of radionuclides through nanocarriers targeted delivery for tumor imaging and therapy offers the new possibility of large increases in cancer diagnostic efficacy and therapeutic index. However, further efforts and challenges in preclinical and clinical efficacy and toxicity studies are required to translate those advanced technologies to the clinical applications for cancer patients.

  4. A vector Wiener filter for dual-radionuclide imaging

    International Nuclear Information System (INIS)

    Links, J.M.; Prince, J.L.; Gupta, S.N.

    1996-01-01

    The routine use of a single radionuclide for patient imaging in nuclear medicine can be complemented by studies employing two tracers to examine two different processes in a single organ, most frequently by simultaneous imaging of both radionuclides in two different energy windows. In addition, simultaneous transmission/emission imaging with dual-radionuclides has been described, with one radionuclide used for the transmission study and a second for the emission study. There is thus currently considerable interest in dual-radionuclide imaging. A major problem with all dual-radionuclide imaging is the crosstalk between the two radionuclides. Such crosstalk frequently occurs, because scattered radiation from the higher energy radionuclide is detected in the lower energy window, and because the lower energy radionuclide may have higher energy emissions which are detected in the higher energy window. The authors have previously described the use of Fourier-based restoration filtering in single photon emission computed tomography (SPECT) and positron emission tomography (PET) to improve quantitative accuracy by designing a Wiener or other Fourier filter to partially restore the loss of contrast due to scatter and finite spatial resolution effects. The authors describe here the derivation and initial validation of an extension of such filtering for dual-radionuclide imaging that simultaneously (1) improves contrast in each radionuclide's direct image, (2) reduces image noise, and (3) reduces the crosstalk contribution from the other radionuclide. This filter is based on a vector version of the Wiener filter, which is shown to be superior [in the minimum mean square error (MMSE) sense] to the sequential application of separate crosstalk and restoration filters

  5. Automatic alignment of radionuclide images

    International Nuclear Information System (INIS)

    Barber, D.C.

    1982-01-01

    The variability of the position, dimensions and orientation of a radionuclide image within the field of view of a gamma camera hampers attempts to analyse the image numerically. This paper describes a method of using a set of training images of a particular type, in this case right lateral brain images, to define the likely variations in the position, dimensions and orientation for that type of image and to provide alignment data for a program that automatically aligns new images of the specified type to a standard position, size and orientation. Examples are given of the use of this method on three types of radionuclide image. (author)

  6. General program for the advancement of the radionuclide technology

    International Nuclear Information System (INIS)

    1979-12-01

    The 'General Program for the Advancement of the Radionuclide Technology' was elaborated in 1978 by the 'Arbeitsgemeinschaft zur Foerderung der Radionuklidtechnik' (AFR) (Association for the Promotion of Radionuclide Technology). In addition to an inventory of the major applications of radionuclide technology, this General Program includes a comprehensive description of tasks relating to the central topics of raw materials, environment, technology and materials, health and nutrition, scientific developments of radionuclide technology. The 'General Program for the Advancement of the Radionuclide Technology' serves inter alia as a basis of evaluation in opinions on funding applications filed with the Federal Ministry for Research and Technology (BMFT) with respect to the provision of advanced techniques involving radionuclides for industrial application. (orig.) [de

  7. Luminescence imaging using radionuclides: a potential application in molecular imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Il An, Gwang; Park, Se-Il; Oh, Jungmin; Kim, Hong Joo; Su Ha, Yeong; Wang, Eun Kyung; Min Kim, Kyeong; Kim, Jung Young; Lee, Jaetae; Welch, Michael J.; Yoo, Jeongsoo

    2011-01-01

    Introduction: Nuclear and optical imaging are complementary in many aspects and there would be many advantages when optical imaging probes are prepared using radionuclides rather than classic fluorophores, and when nuclear and optical dual images are obtained using single imaging probe. Methods: The luminescence intensities of various radionuclides having different decay modes have been assayed using luminescence imaging and in vitro luminometer. Radioiodinated Herceptin was injected into a tumor-bearing mouse, and luminescence and microPET images were obtained. The plant dipped in [ 32 P]phosphate solution was scanned in luminescence mode. Radio-TLC plate was also imaged in the same imaging mode. Results: Radionuclides emitting high energy β + /β - particles showed higher luminescence signals. NIH3T6.7 tumors were detected in both optical and nuclear imaging. The uptake of [ 32 P]phosphate in plant was easily followed by luminescence imaging. Radio-TLC plate was visualized and radiochemical purity was quantified using luminescence imaging. Conclusion: Many radionuclides with high energetic β + or β - particles during decay were found to be imaged in luminescence mode due mainly to Cerenkov radiation. 'Cerenkov imaging' provides a new optical imaging platform and an invaluable bridge between optical and nuclear imaging. New optical imaging probes could be easily prepared using well-established radioiodination methods. Cerenkov imaging will have more applications in the research field of plant science and autoradiography.

  8. Evaluation of the specificity of radionuclide myocardial imaging for detecting CAD

    International Nuclear Information System (INIS)

    Liu Xiujie

    1992-01-01

    In order to evaluate the specificity of radionuclide myocardial perfusion imaging for detecting coronary artery disease (CAD), 50 patients with normal coronary arteriography and radionuclide myocardial perfusion scintigraphy were analysed. The results from 201 T1 (20 cases) and 99m Tc-MIBI (30 cases) studies showed that out of 33 patients with no organic cardiovascular disease, 29 had normal myocardial imaging, and the specificity of radionuclide myocardial imaging for detecting CAD was 87.8%. 4 normal young women had false positive myocardial imaging. Out of 17 patients with cardiovascular disease and normal coronary arteriography, 15 patients had abnormal myocardial imaging. The final clinical diagnoses of these 15 patients were: 4 patients with hypertrophic cardiomyopathy, 3 with old myocardial infarction, 2 with myocarditis, 3 with small coronary vessel disease, 1 with congestive cardiomyopathy, and 2 with other cardiac disorder. The points of differentiation between CAD and other cardiovascular disease using radionuclide techniques were discussed

  9. Radionuclide imaging of musculoskeletal infection

    International Nuclear Information System (INIS)

    Palestr, Christopher J.; North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY; Love, Charito

    2007-01-01

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  10. Radionuclide imaging of musculoskeletal infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestr, Christopher J. [Albert Einstein College of Medicine, Bronx, NY (United States); North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging; E-mail: palestro@lij.edu; Love, Charito [North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging

    2007-09-15

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  11. Application of radionuclide imaging in hyperparathyroidism

    International Nuclear Information System (INIS)

    Zheng Yumin; Yan Jue

    2011-01-01

    Hyperparathyroidism (HPT) is overactivity of the parathyroid glands resulting in excess production of parathyroid hormone. Excessive parathyroid hormone secretion may be due to problems in the glands themselves, or may be secondary HPT. The diagnosis is mainly based on the patient's medical history and biochemical tests. The best treatment nowadays is surgical removal of the overactive parathyroid glands or adenoma. The imaging methods for the preoperative localization diagnosis include radionuclide imaging,ultrasonography, CT, MRI, etc. This article was a summary of HPT radionuclide imaging. (authors)

  12. Bone stress: a radionuclide imaging perspective

    International Nuclear Information System (INIS)

    Roub, L.W.; Gumerman, L.W.; Hanley, E.N. Jr.; Clark, M.W.; Goodman, M.; Herbert, D.L.

    1979-01-01

    Thirty-five college athletes with lower leg pain underwent radiography and radionuclide studies to rule out a stress fracture. Their asymptomatic extremities and 13 pain-free athletes served as controls. Four main patterns were observed: (a) sharply marginated scintigraphic abnormalities and positive radiographs; (b) sharply marginated scintigraphic abnormalities and negatives radiographs; (c) ill-defined scintigraphic abnormalities and negative radiographs; and (d) negative radionuclide images and negative radiographs. Since the patients with the first two patterns were otherwise identical medically, the authors feel that this scintigraphic appearance is characterisic of bone stress in the appropriate clinical setting, regardless of the radiographic findings. A schema is proposed to explain the occurrence of positive radionuclide images and negative radiographs in the same patient, using a broad conceptual approach to the problem of bone stress

  13. Miscellaneous applications of radionuclide imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.; Freeman, L.M.

    1984-01-01

    The procedures discussed in this chapter are either developmental, in limited clinical use, or frankly moribund. A number of radionuclide imaging techniques have proved disappointing when approached from a purely anatomic point of view. This is particularly evident to our colleagues with the explosive growth of the noninvasive imaging procedures, magnetic resonance imaging (NMR), CT, and ultrasound, and the introduction of the less invasive digital radiographic approach to vascular opacification, all of which are capable of providing exquisite anatomic or tissue detail beyond the reach of current or reasonably priced nuclear medicine imaging systems. Yet, most nuclear medicine procedures possess the unique advantage of portraying a physiologic function without interfering with that function. Moreover, the procedures can be employed under conditions of stress, which are likely to bring out pathophysiologic abnormalities that remain masked when unchallenged. Information concerning form without functional data has less meaning than both together. The physiologic information inherent in nuclear medicine imaging may often provide not only key diagnostic information but also illuminate a therapeutic trail. Yet, it is often slighted in favor of the anatomic quest. While mastery of the nuances of imaging details remains critical, radionuclide image interpretation must rest upon a firm physiologic foundation. For this reason, this chapter emphasizes the physiologic approach

  14. β-ray track imaging application in phytoremediation of radionuclide-contaminated soil

    International Nuclear Information System (INIS)

    Wan Junsheng; Xiao Yan; Pan Xiaobing; Tang Xiuhuan; Yang Yongqing; Wang Beisong; Zhao Xiangfeng; Li Hua; Miao Zhengqiang; Yang Jun

    2008-01-01

    The phytoremediation was widely studied in the field of treating technology of soil contamination with long-lived nuclides. Studies on the β-ray track imaging application in phytoremediation of radionuclide-contaminated soil were carried out in the present work. Experiments showed that this technology might be used for screening plants for phytoremediation and for the studies of phytoremediation mechanism, such as radioactivity concentration and distribution in plant organs. The influence of α- and γ-rays on the β-ray track imaging was studied. Theoretical studies showed that the influence of α-rays might be heavily reduced with proper thickness of PE-film. The image sensor was not so sensitive to γ-rays as β-rays, and the influence of surrounding γ-rays could be heavily reduced with a proper thickness of Pb-shielding

  15. Development of long-lived radionuclide transmutation technology -Development of long-lived radionuclide handling technology-

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Hoh; Jung, Won Myung; Lee, Kyoo Il; Woo, Moon Sik; Cho, Kyung Tae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    The final goals of this research are completion of design for construction of wet hot cell and auxiliary facilities, and development of main equipments and technologies for remote operation and near real time monitoring system of radioactivity of solution. This wet hot cell and technology will be used for active test of the radionuclide partitioning process and for fission Mo separation and purification process. And high level radioactive and toxic materials will be treated as the form of solution in this wet hot cell. In this R. and D., the important objectives are (1)to provide safe operation, and (2)to keep radiation exposure to staff as low as practicable, (3)to protect the environment. 34 figs, 22 tabs, 44 refs. (Author).

  16. Radionuclide body function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1983-01-01

    A transverse radionuclide scan field imaging apparatus is claimed. It comprises: a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; means for rotating the array about the scan field and means for imparting travel to the collimators

  17. Application of radionuclide imaging to hepatic impact injury in rabbits

    Institute of Scientific and Technical Information of China (English)

    金榕兵; 麻晓林; 温建良; 唐维佳

    2004-01-01

    Objective: To investigate the role and clinical value of radionuclide imaging in hepatic impact injuries in rabbits.Methods: Rabbits were experimentally impacted on the liver with BIM-IV bio-impact machine. Liver imaging was performed with 99mTc labeled sodium phytate. Liver blood pool imaging was performed with 99mTc -stannous pyrophosphate labeled red blood cells. The results of radionuclide imaging were compared with the anatomic results.Results: There was significant difference between the images of the injured liver and the control. Radio diminution and defect were shown in the injured liver areas. Various sorts of abnormal radioactivity distribution were observed with hepatic blood pool imaging. The results of the liver imaging and liver blood pool imaging were accorded with the results of the anatomic findings.Conclusions: Radionuclide imaging may well display the changes of hepatocellular structures and functions after injury, which is valuable in locating the concrete injured position and differentiating the injured degrees of liver.

  18. Recent advances and future projections in clinical radionuclide imaging

    International Nuclear Information System (INIS)

    Peters, A.M.

    1990-01-01

    This outline review of recent advances in radionuclide imaging draws attention to developments in nuclear medicine of the urinary tract such as Captopril renography and the introduction of MAG-3, the technetium-99m labelled mimic of hippuran, the use of radionuclides for infection diagnosis, advances in lung perfusion scanning, new radiopharmaceuticals for cardiac imaging, and developments in radiopharmaceuticals for imaging tumours, including gallium-67, thallium-201, and the development of radiolabelled monoclonal antibodies. Attention is drawn to the wider use of nuclear medicine in child care. (author)

  19. Application of radionuclides in nuclear technology

    International Nuclear Information System (INIS)

    Boeck, H.

    1983-07-01

    Four main applications of radionuclides in nuclear technology are presented which are level-, density- and thickness gauging and moisture determination. Each method is surveyed for its general principle, various designs, accuracy, errors and practical designs. (Author)

  20. Clinical advance in radionuclide imaging of pulmonary cancer

    International Nuclear Information System (INIS)

    Deng Zhiyong; Yang Lichun

    2008-01-01

    Radionuclide imaging of pulmonary cancer develops very rapidly in recent years. Its important value on the diagnosis, staging, monitoring recur and metastasis after treatment, and judging the curative effect and prognosis has been demonstrated. Clinicians pay more attention to it than before. This present article introduces the imaging principle, clinical use, good and bad points, progress situation of 67 Ga, 201 Tl, 99 Tc m , 18 F and their labelled compounds, which are more commonly used in clinical. And introduces the clinical progress of radionuclide imaging of pulmonary neoplasm concerning 99 Tc m -sestamibi ( 99 Tc m -MIBI), 99 Tc m -HL91 and 18 F-fluorodeoxyglucose ( 18 F-FDG) with emphasis. (authors)

  1. Radionuclide Imaging Technologies for Biological Systems

    Energy Technology Data Exchange (ETDEWEB)

    Howell, Calvin R. [Duke Univ., Durham, NC (United States); Reid, Chantal D. [Duke Univ., Durham, NC (United States); Weisenberger, Andrew G. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2014-05-14

    The main objective of this project is to develop technologies and experimental techniques for studying the dynamics of physiological responses of plants to changes in their interface with the local environment and to educate a new generation of scientists in an interdisciplinary environment of biology, physics and engineering. Also an important goal is to perform measurements to demonstrate the new data that can be produced and made available to the plant-biology community using the imaging technologies and experimental techniques developed in this project. The study of the plant-environment interface includes a wide range of topics in plant physiology, e.g., the root-soil interface, resource availability, impact of herbivores, influence of microbes on root surface, and responses to toxins in the air and soil. The initial scientific motivation for our work is to improve understanding of the mechanisms for physiological responses to abrupt changes in the local environment, in particular, the responses that result in short-term adjustments in resource (e.g., sugars, nutrients and water) allocations. Data of time-dependent responses of plants to environmental changes are essential in developing mechanistic models for substance intake and resource allocation. Our approach is to use radioisotope tracing techniques to study whole-plant and plant organ (e.g., leaves, stems, roots) dynamical responses to abrupt changes in environmental conditions such as concentration of CO2 in the atmosphere, nutrient availability and lighting. To this aim we are collaborating with the Radiation Detector and Imaging Group at the Thomas Jefferson National Laboratory Facility (JLab) to develop gamma-ray and beta particle imaging systems optimized for plant studies. The radioisotope tracing measurements are conducted at the Phytotron facility at Duke University. The Phytotron is a controlled environment plant research facility with a variety of plant growth chambers. One chamber

  2. Radionuclide imaging of spinal infections

    International Nuclear Information System (INIS)

    Gemmel, Filip; Dumarey, Nicolas; Palestro, Christopher J.

    2006-01-01

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor 99m Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and 67 Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [ 18 F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including radiolabelled

  3. Radionuclide imaging of non osseous infection

    International Nuclear Information System (INIS)

    Palestro, C.J.; New York, Yeshiva Univ., NY; Torres, M.A.

    1999-01-01

    Nuclear medicine is an important tool in the diagnostic evaluation of patients with a variety of non osseous infections. In the immunocompetent population labeled leukocyte imaging is the radionuclide procedure of choice, with Gallium imaging reserved for those situations in which the leukocyte study is non diagnostic or cannot be performed. Fever of unknown origin is caused by infection in less than one-third of cases, and therefore the number of positive leukocyte studies will be relatively low. The negative leukocyte study is also useful as it has been demonstrated that a negative study excludes, with a high degree of certainty, focal infection as the cause of an FUO. In the cardiovascular system, labeled leukocyte scintigraphy is very useful for diagnosing mycotic aneurysms and infected prosthetic vascular grafts. The specificity of the study is somewhat more variable. In the central nervous system, labeled leukocyte imaging can provide important information about the etiology of contrast enhancing brain lesions identified on computed tomography. In the immunocompromised population, typified by the AIDS patient, Gallium scintigraphy is the radionuclide procedure of choice for diagnosing opportunistic diseases. In the thorax, a normal Gallium scan, in the setting of a negative chest X-ray, virtually excludes pulmonary disease. In the abdomen, Gallium is also useful for detecting nodal disease, but is not reliable for detecting large bowel disease. Labeled leukocyte imaging should be performed when colitis is a concern. Both 18 FDG PET and 201 T1 SPECT imaging of the brain are useful for distinguishing between central nervous system lymphoma and toxoplasmosis in the HIV (+) patient. On both studies, lymphoma manifests as a focus of increased tracer uptake, whereas toxoplasmosis shows little or no uptake of either tracer

  4. Radionuclide imaging of non osseous infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, C.J. (Long Island Jewish Medical Center, New York, NY, (United States). Dept. Nuclear Medicine New York, Yeshiva Univ., NY (United States). Albert Einstein College of Medicine); Torres, M.A. (Long Island Jewish Medical Center, New York, NY, (United States). Dept. Nuclear Medicine)

    1999-03-01

    Nuclear medicine is an important tool in the diagnostic evaluation of patients with a variety of non osseous infections. In the immunocompetent population labeled leukocyte imaging is the radionuclide procedure of choice, with Gallium imaging reserved for those situations in which the leukocyte study is non diagnostic or cannot be performed. Fever of unknown origin is caused by infection in less than one-third of cases, and therefore the number of positive leukocyte studies will be relatively low. The negative leukocyte study is also useful as it has been demonstrated that a negative study excludes, with a high degree of certainty, focal infection as the cause of an FUO. In the cardiovascular system, labeled leukocyte scintigraphy is very useful for diagnosing mycotic aneurysms and infected prosthetic vascular grafts. The specificity of the study is somewhat more variable. In the central nervous system, labeled leukocyte imaging can provide important information about the etiology of contrast enhancing brain lesions identified on computed tomography. In the immunocompromised population, typified by the AIDS patient, Gallium scintigraphy is the radionuclide procedure of choice for diagnosing opportunistic diseases. In the thorax, a normal Gallium scan, in the setting of a negative chest X-ray, virtually excludes pulmonary disease. In the abdomen, Gallium is also useful for detecting nodal disease, but is not reliable for detecting large bowel disease. Labeled leukocyte imaging should be performed when colitis is a concern. Both [sup 18]FDG PET and [sup 201]T1 SPECT imaging of the brain are useful for distinguishing between central nervous system lymphoma and toxoplasmosis in the HIV (+) patient. On both studies, lymphoma manifests as a focus of increased tracer uptake, whereas toxoplasmosis shows little or no uptake of either tracer.

  5. Radionuclide bone image in growing and stable bone island

    International Nuclear Information System (INIS)

    Go, R.T.; El-Khoury, G.Y.; Iowa Univ., Iowa City; Wehbe, M.A.

    1980-01-01

    A normal radionuclide bone image can facilitate distinction between a bone island and significant pathologic processes, especially an osteoblastic metastasis. This distinction becomes more crucial when growth is detected in an isolated sclerotic bone lesion or if a relatively large sclerotic lesion is detected de novo in patients with a known neoplasm. This report presents three patients with isolated bone islands: two with interval growth, the other with a relatively large stable lesion; all showing a normal radionuclide bone image. (orig.) [de

  6. Development and application of high energy imaging technology

    International Nuclear Information System (INIS)

    Chen Shengzu

    1999-01-01

    High Energy Positron Imaging (HEPI) is a new technology. The idea of positron imaging can be traced back to early 1950's. HEPI imaging is formed by positron emitter radionuclide produced by cyclotron, such as 15 O, 13 N, 11 C and 18 F, which are most abundant elements in human body. Clinical applications of HEPI have been witnessed rapidly in recent years. HEPI imaging can be obtained by both PET and SPECT, namely high energy collimation imaging, Mdecular Coincidence Detection (MCD) and positron emission tomography

  7. Development of long-lived radionuclide partitioning technology

    International Nuclear Information System (INIS)

    Lee, Eil Hee; Kwon, S. G.; Yang, H. B.

    2001-04-01

    This project was aimed at the development of an optimal process that could get recovery yields of 99% for Am and Np and 90% for Tc from a simulated radioactive waste and the improvements of unit processes. The performed works are summarized, as follows. 1) The design and the establishment of a laboratory-scale partitioning process were accomplished, and the interfacial conditions between each unit process were determined. An optimal flow diagram for long-lived radionuclide partitioning process was suggested. 2) In improvements of unit processes, a) Behaviors of the co-extraction and sequential separation for residual U, Np and Tc(/Re) by chemical and electrochemical methods were examined. b) Conditions for co-extraction of Am/RE, and selective stripping of Am with metal containing extractant and a mixed extractant were decided. c) Characteristics of adsorption and elution by ion exchange chromatography and extraction chromatography methods were analysed. d) The simulation codes for long-lived radionuclide partitioning were gathered. and reaction equations were numerically formulated. 3) An existing γ-lead cell was modified the α-γ cells for treatment of long-lived radioactive materials. 4) As the applications of new separation technologies, a) Behaviors of photo reductive precipitation for Am/RE were investigated, b) Conditions for selective extraction and stripping of Am with pyridine series extractants were established. All results will be used as the fundamental data for establishment of partitioning process and radiochemical test of long-lived radionuclides recovery technology to be performed in the next stage

  8. Radionuclide imaging of spinal infections

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [Ghent Maria-Middelares, General Hospital, Division of Nuclear Medicine, Ghent (Belgium); Medical Center Leeuwarden (MCL), Division of Nuclear Medicine, Henri Dunantweg 2, Postbus 888, Leeuwarden (Netherlands); Dumarey, Nicolas [Universite Libre de Bruxelles, Hopital Erasme, Division of Nuclear Medicine, Brussels (Belgium); Palestro, Christopher J. [Long Island Jewish Medical Center, Division of Nuclear Medicine, Long Island, NY (United States)

    2006-10-15

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor {sup 99m}Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and {sup 67}Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [{sup 18}F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including

  9. Internal radiation dosimetry using nuclear medicine imaging in radionuclide therapy

    International Nuclear Information System (INIS)

    Kim, Kyeong Min; Byun, Byun Hyun; Cheon, Gi Jeong; Lim, Sang Moo

    2007-01-01

    Radionuclide therapy has been an important field in nuclear medicine. In radionuclide therapy, relevant evaluation of internally absorbed dose is essential for the achievement of efficient and sufficient treatment of incurable disease, and can be accomplished by means of accurate measurement of radioactivity in body and its changes with time. Recently, the advances of nuclear medicine imaging and multi modality imaging processing techniques can provide chance of more accurate and easier measurement of the measures commented above, in cooperation of conventional imaging based approaches. In this review, basic concept for internal dosimetry using nuclear medicine imaging is summarized with several check points which should be considered in real practice

  10. Detection and evaluation of left atrial myxoma by gated radionuclide imaging

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Adachi, Haruhiko; Nakagawa, Hiroaki

    1985-01-01

    Radionuclide imaging plays an important role in diagnosising left atrial myxoma (LAM). We discussed diagnostic value of Fourier analysis with phase image and evaluated left ventricular filling function using indices such as 1/3 Filling Fraction, Rapid Filling Fraction and Peak Filling Rate derived from left ventricular volume curve. Equillibrium radionuclide angiocardiography was performed in 6 LAM patients. Phase delay in the basal portion of the left ventricle was shown in 5 of 6 LAM patients, and standard deviation of left ventricular phase was larger than these of controls. Left ventricular filling disturbance was suggested in 5 of 6 LAM patients. After surgical remove of myxoma phase delay was disappeared and standard deviation was normalized. And left ventricular filling was improved. We concluded that the phase image of Fourier analysis revealed a left atrial mass prolapsing in the left ventricule during the diastole, and that diastolic indices were useful for left ventricular filling disturbance due to LAM. (author)

  11. Current status of radionuclide imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, C.A.; Okada, R.D.; Pohost, G.M.

    1980-12-18

    The current state-of-the-art in radionuclide imaging of valvular heart disease is based on different angiographic patterns in three left-sided valve abnormalities: pressure overload, volume overload, and inflow obstruction. In pressure overload, the left ventricle has normal dimensions or is minimally dilated the volume overload involves a left ventricular dilatation with a normal or reduced ejection fraction at rest the left ventricular function in inflow obstruction is normal, but in some cases may be depressed. Radionuclide angiography evaluates the effect of a valve abnormality on cardiac chamber and function thallium-201 imaging diagnoses regional myocardial blood flow and cell integrity and can evaluate the associated coronary artery disease.

  12. Current status of radionuclide imaging in valvular heart disease

    International Nuclear Information System (INIS)

    Boucher, C.A.; Okada, R.D.; Pohost, G.M.

    1980-01-01

    The current state-of-the-art in radionuclide imaging of valvular heart disease is based on different angiographic patterns in three left-sided valve abnormalities: pressure overload, volume overload, and inflow obstruction. In pressure overload, the left ventricle has normal dimensions or is minimally dilated the volume overload involves a left ventricular dilatation with a normal or reduced ejection fraction at rest the left ventricular function in inflow obstruction is normal, but in some cases may be depressed. Radionuclide angiography evaluates the effect of a valve abnormality on cardiac chamber and function thallium-201 imaging diagnoses regional myocardial blood flow and cell integrity and can evaluate the associated coronary artery disease

  13. Radionuclide transverse section imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1980-01-01

    A radioisotope scanning apparatus for use in nuclear medicine is described in detail. The apparatus enables the quantification and spatial location of the radioactivity in a body section of a patient to be determined with high sensitivity. It consists of an array of highly focussed collimators arranged such that adjacent collimators move in the same circumferential but opposite radial directions. The explicit movements of the gantry are described in detail and may be controlled by a general purpose computer. The use of highly focussed collimators allows both a reasonable solid angle of acceptance and also high target to background images; additionally, dual radionuclide pharmaceutical studies can be performed simultaneously. It is claimed that the high sensitivity of the system permits the early diagnosis of pathological changes and the images obtained show accurately the location and shape of physiological abnormalities. (UK)

  14. Osteopetrosis: Radiological & Radionuclide Imaging

    International Nuclear Information System (INIS)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent 99m Tc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis

  15. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  16. Radionuclide imaging with coded apertures and three-dimensional image reconstruction from focal-plane tomography

    International Nuclear Information System (INIS)

    Chang, L.T.

    1976-05-01

    Two techniques for radionuclide imaging and reconstruction have been studied;; both are used for improvement of depth resolution. The first technique is called coded aperture imaging, which is a technique of tomographic imaging. The second technique is a special 3-D image reconstruction method which is introduced as an improvement to the so called focal-plane tomography

  17. EANM 2012 guidelines for radionuclide imaging of phaeochromocytoma and paraganglioma

    NARCIS (Netherlands)

    Taieb, D.; Timmers, H.J.L.M.; Hindie, E.; Guillet, B.A.; Neumann, H.P.; Walz, M.K.; Opocher, G.; de Herder, W.W.; Boedeker, C.C.; de Krijger, R.R.; Chiti, A.; Al-Nahhas, A.; Pacak, K.; Rubello, D.

    2012-01-01

    PURPOSE: Radionuclide imaging of phaeochromocytomas (PCCs) and paragangliomas (PGLs) involves various functional imaging techniques and approaches for accurate diagnosis, staging and tumour characterization. The purpose of the present guidelines is to assist nuclear medicine practitioners in

  18. Radionuclide imaging of musculoskeletal infection

    Directory of Open Access Journals (Sweden)

    Christopher J. Palestro

    2007-09-01

    Full Text Available Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of "complicating osteomyelitis" such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose.Estudos através de imagens com o uso de radionuclídeos são rotineiramente usadas para avaliar pacientes suspeitos de terem infecção músculo-esquelética. A imagem óssea em tridimensional é facilmente avaliável, relativamente de baixo custo, e muito precisa na localização de alterações ósseas. Imagem com leucócito marcado poderia ser usada nos casos de "osteomielite com complicações" tais como infecção prostética articular. Esse teste também é útil na não suspeita clinica de osteomielite associada ao pé diabético tanto quanto nas junções neuropáticas. É sempre necessário, por outro lado, realizar imagem complementar da medula óssea para aumentar a precisão da imagem com leucócito marcado. Em contraste com outras regiões no esqueleto, imagem com leucócito marcado não é útil para diagnosticar osteomielite da coluna vertebral. Até agora, o gálio é o radionuclídeo preferido para

  19. Translational Applications of Molecular Imaging and Radionuclide Therapy

    International Nuclear Information System (INIS)

    Welch, Michael J.; Eckelman, William C.; Vera, David

    2005-01-01

    Molecular imaging is becoming a larger part of imaging research and practice. The Office of Biological and Environmental Research of the Department of Energy funds a significant number of researchers in this area. The proposal is to partially fund a workshop to inform scientists working in nuclear medicine and nuclear medicine practitioners of the recent advances of molecular imaging in nuclear medicine as well as other imaging modalities. A limited number of topics related to radionuclide therapy will also be discussed. The proposal is to request partial funds for the workshop entitled ''Translational Applications of Molecular Imaging and Radionuclide Therapy'' to be held prior to the Society of Nuclear Medicine Annual Meeting in Toronto, Canada in June 2005. The meeting will be held on June 17-18. This will allow scientists interested in all aspects of nuclear medicine imaging to attend. The chair of the organizing group is Dr. Michael J. Welch. The organizing committee consists of Dr. Welch, Dr. William C. Eckelman and Dr. David Vera. The goal is to invite speakers to discuss the most recent advances of modern molecular imaging and therapy. Speakers will present advances made in in vivo tagging imaging assays, technical aspects of small animal imaging, in vivo imaging and bench to bedside translational study; and the role of a diagnostic scan on therapy selection. This latter topic will include discussions on therapy and new approaches to dosimetry. Several of these topics are those funded by the Department of Energy Office of Biological and Environmental Research

  20. Evaluation and selection of aqueous-based technology for partitioning radionuclides from ICPP calcine

    International Nuclear Information System (INIS)

    Olson, A.L.; Schulz, W.W.; Burchfield, L.A.; Carlson, C.D.; Swanson, J.L.; Thompson, M.C.

    1993-02-01

    Early in 1993 Westinghouse Idaho Nuclear Company (WINCO) chartered a Panel of Nuclear Separations Experts. The purpose of this Panel was to assist WINCO scientists and engineers in selecting, evaluating, and ranking candidate aqueous-based processes and technologies for potential use in partitioning selected radionuclides from nitric acid solutions of retrieved Idaho Chemical Processing Plant (ICPP) calcine. Radionuclides of interest are all transuranium elements, 90 Sr, 99 Tc, 129 I, and 137 Cs. The six man Panel met for 4 days (February 16--19, 1993) on the campus of the Idaho State University in Pocatello, Idaho. Principal topics addressed included: Available radionuclide removal technology; applicability of separations technology and processes to ICPP calcine; and potential integrated radionuclide partitioning schemes. This report, prepared from contributions from all Panel members, presents a comprehensive account of the proceedings and significant findings of the February, 1993 meeting in Pocatello

  1. High-tension electrical injury to the heart as assessed by radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Iino, Hitoshi; Chikamori, Taishiro; Hatano, Tsuguhisa [Tokyo Medical Coll. (Japan)] [and others

    2002-12-01

    The purpose of this study was to evaluate cardiac complications associated with electrical injury, 7 patients with high-tension electrical injury (6,600 V alternating current) underwent {sup 201}Tl and {sup 123}I-metaiodobenzylguanidine (MIBG) imaging in addition to conventional electrocardiographic and echocardiographic assessments. Electrocardiography showed transient atrial fibrillation, second degree atrioventricular block, ST-segment depression, and sinus bradycardia in each patient. Echocardiography showed mild hypokinesis of the anterior wall in only 2 patients, but {sup 201}Tl and {sup 123}I-MIBG myocardial scintigraphy showed an abnormal scan image in 6/7 and 5/6 patients, respectively. Decreased radionuclide accumulation was seen primarily in areas extending from the anterior wall to the septum. Decreased radionuclide accumulation was smaller in extent and milder in degree in {sup 123}I-MIBG than in {sup 201}Tl imaging. These results suggest that even in patients without definite evidence of severe cardiac complications in conventional examinations, radionuclide imaging detects significant damage due to high-tension electrical injury, in which sympathetic nerve dysfunction might be milder than myocardial cell damage. (author)

  2. Report of the consultants' meeting on target and processing technologies for cyclotron production of radionuclides

    International Nuclear Information System (INIS)

    1999-11-01

    Cyclotron produced radionuclides are used routinely for the diagnosis of a wide variety of diseases. Recently a number of radionuclides available from cyclotrons have been proposed for use in radiotherapy. In fact Pd-103 has become routinely available in some parts of the world for incorporation into brachytherapy seeds for treating prostate cancer. The consultants meeting reviewed the status of target and processing technologies associated with cyclotron production of radionuclides. The main topics of discussion included the basic nuclear data that is crucial to the production of the desired radionuclides, gas and solid target systems, the automated chemical processing units, the Good Manufacturing Practices (GMP) required in order to use these radionuclides in human patients in a safe and efficacious manner and a review of possible candidate nuclides that show promise for use in Nuclear Medicine in the near future. Advances in the preparation of solid targets using electroplating technology has created the possibility of preparing targets capable of operating at very high beam currents which would make the production of large quantities of SPECT agents possible at cyclotron facilities throughout the world. Recognising the needs of the developing countries which have established cyclotron facilities, the consultants focussed on how to provide the technology for preparing solid targets that could be used in the existing facilities. While solid target technology can be used for many radionuclides the report concentrated on several key radionuclides, which are of current importance or show potential for use in the near future. Tl-201 is currently used for cardiac profusion studies throughout the world. New target preparation techniques could potentially make many of the member states self sufficient in the production of this nuclide. I-123 has tremendous potential because of the near ideal photon energy for SPECT cameras and its well-understood chemistry. However, it

  3. Diagnostic value of radionuclide imaging combined with routine CT in detecting hepatic focal nodular hyperplasia

    International Nuclear Information System (INIS)

    Lu Xuemin; Yu Shuhong; Han Jiankui

    2011-01-01

    Objective: To investigate radionuclide imaging and routine CT in diagnosing hepatic focal nodular hyperplasia (FNH) and the combined diagnostic value of the two modalities. Methods: Thirty-two patients with hepatic FNH were retrospectively studied. All patients underwent routine CT scan. Twenty-four patients were examined by 99 Tc m -sulfur colloid (SC) hepatic planar scintigraphy and SPECT/CT imaging, and then patients who had abnormal foci underwent 99 Tc m -diethyl iminodiacetic acid (EHIDA) triple-phase hepatobiliary imaging. χ 2 -test of four-table or Fisher exact probabilities in 2 × 2 table was applied for statistical analysis. Results: Of all 32 patients pathologically diagnosed as FNH with single solitary nodule, 25 were classified as classic type and the rest 7 as non-classic type. Although routine CT found all hepatic lesions, only 15 cases were diagnosed pathologically as FNH classic type but the rest were either misdiagnosed or left as indeterminate. On radionuclide imaging (hepatic colloid scintigraphy plus triple-phase hepatobiliary images), 11 patients with big foci (with maximal diameter >3 cm) out of 24 patients were correctly diagnosed as FNH, with 7 diagnosed as classic type FNH and 4 as non-classic. Other 13 patients were either misdiagnosed or simply missed. The diagnosing rates of routine CT and radionuclide imaging were 60.0% (15/25) and 38.9% (7/18) for FNH classic type, 0/7 and 4/6 for non-classic type, 50.0% (10/20) and 73.3% (11/15) for big foci, 41.7% (5/12) and 0/9 for small foci (with maximal diameter ≤3 cm), respectively. The total diagnosing rate of radionuclide imaging combined with routine CT was significantly higher than that of routine CT or radionuclide imaging alone (χ 2 =4.48, P<0.05; χ 2 =4.27, P<0.05). Conclusion: Radionuclide imaging in combination with routine CT may improve the diagnostic accuracy for hepatic FNH patients. (authors)

  4. EANM/ESC guidelines for radionuclide imaging of cardiac function

    DEFF Research Database (Denmark)

    Hesse, B.; Lindhardt, T.B.; Acampa, W.

    2008-01-01

    radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes...

  5. Evaluation of cardiac involvement using radionuclide myuocardial imaging in patients with Takayasu arteritis

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Jiang Xiongjing; Dou Kefei

    2008-01-01

    Objective: The aim of the study was to assess the value of radionuclide myocardial imaging in the evaluation of cardiac involvement in patients with Takayasu arteritis (TA). Methods: The 99 Tc m -methoxyisobutylisonitrile myocardial perlusion imaging (MIBI-MPI) and (or) 18 F-fluorodeoxyglucose (FDG) PET imaging findings in 12 TA patients [3 men and 9 women, mean age (35 ± 15) years] with coronary lesions (CL; n=8) or aortic insufficiency (AI; n=4) were retrospectively reviewed and analysed. Of the 4 AI-TA patients, 1 underwent exercise MIBI-MPI, 1 underwent pharmacologic stress MIBI-MPI and 2 un- derwent resting MIBI-MPI. Of the 8 CL-TA patients, 4 pnderwent MIBI-MPI (2 stress and 2 rest) and 4 un- derwent a dual-isotope simultaneous acquisition (DISA) SPECT protocol after injection of MIBI and FDG. Results: All 4 AI-TA patients showed left ventricular enlargement but no peffusion abnormalities. In 3 CL- TA patients with no documented infarct, MPI or DISA showed stress ischemia (n=2) or mismatched perfusion-metabolism defects (n=1). In the remaining 5 CL-TA patients with documented infarcts, 2 showed large perfusion defects on resting MIBI and 3 showed matched perfusion-metabolism defects on DISA SPECT. Conclusion: Radionuclide imaging is useful in providing a comprehensive functional evaluation for TA patients with cardiac involvement. (authors)

  6. Radionuclide brain imaging in acquired immunodeficiency syndrome (AIDS)

    International Nuclear Information System (INIS)

    Costa, D.C.; Gacinovic, S.; Miller, R.F.

    1995-01-01

    Infection with the Human Immunodeficiency Virus type 1 (HIV-1) may produce a variety of central nervous system (CNS) symptoms and signs. CNS involvement in patients with the Acquired Immunodeficiency Syndrome (AIDS) includes AIDS dementia complex or HIV-1 associated cognitive/motor complex (widely known as HIV encephalopathy), progressive multifocal leucoencephalopathy (PML), opportunistic infections such as Toxoplasma gondii, TB, Cryptococcus and infiltration by non-Hodgkin's B cell lymphoma. High resolution structural imaging investigations, either X-ray Computed Tomography (CT scan) or Magnetic Resonance Imaging (MRI) have contributed to the understanding and definition of cerebral damage caused by HIV encephalopathy. Atrophy and mainly high signal scattered white matter abnormalities are commonly seen with MRI. PML produces focal white matter high signal abnormalities due to multiple foci of demyelination. However, using structural imaging techniques there are no reliable parameters to distinguish focal lesions due to opportunistic infection (Toxoplasma gondii abscess) from neoplasm (lymphoma infiltration). It is studied the use of radionuclide brain imaging techniques in the investigation of HIV infected patients. Brain perfusion Single Photon Emission Tomography (SPET), neuroreceptor and Positron Emission Tomography (PET) studies are reviewed. Greater emphasis is put on the potential of some radiopharmaceuticals, considered to be brain tumour markers, to distinguish intracerebral lymphoma infiltration from Toxoplasma infection. SPET with 201 Tl using quantification (tumour to non-tumour radioactivity ratios) appears a very promising technique to identify intracerebral lymphoma

  7. Radionuclide-Based Cancer Imaging Targeting the Carcinoembryonic Antigen

    Directory of Open Access Journals (Sweden)

    Hao Hong

    2008-01-01

    Full Text Available Carcinoembryonic antigen (CEA, highly expressed in many cancer types, is an important target for cancer diagnosis and therapy. Radionuclide-based imaging techniques (gamma camera, single photon emission computed tomography [SPECT] and positron emission tomography [PET] have been extensively explored for CEA-targeted cancer imaging both preclinically and clinically. Briefly, these studies can be divided into three major categories: antibody-based, antibody fragment-based and pretargeted imaging. Radiolabeled anti-CEA antibodies, reported the earliest among the three categories, typically gave suboptimal tumor contrast due to the prolonged circulation life time of intact antibodies. Subsequently, a number of engineered anti-CEA antibody fragments (e.g. Fab’, scFv, minibody, diabody and scFv-Fc have been labeled with a variety of radioisotopes for CEA imaging, many of which have entered clinical investigation. CEA-Scan (a 99mTc-labeled anti-CEA Fab’ fragment has already been approved by the United States Food and Drug Administration for cancer imaging. Meanwhile, pretargeting strategies have also been developed for CEA imaging which can give much better tumor contrast than the other two methods, if the system is designed properly. In this review article, we will summarize the current state-of-the-art of radionuclide-based cancer imaging targeting CEA. Generally, isotopes with short half-lives (e.g. 18F and 99mTc are more suitable for labeling small engineered antibody fragments while the isotopes with longer half-lives (e.g. 123I and 111In are needed for antibody labeling to match its relatively long circulation half-life. With further improvement in tumor targeting efficacy and radiolabeling strategies, novel CEA-targeted agents may play an important role in cancer patient management, paving the way to “personalized medicine”.

  8. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  9. Radionuclide salivary gland imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1981-01-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific

  10. Radionuclide imaging in diagnosis and therapy of the diabetic foot

    International Nuclear Information System (INIS)

    Zhu Cansheng

    2000-01-01

    Early and accurate diagnosis of angiopathy or infection of the diabetic foot is the key to the successful management. Radionuclide imaging is very useful in detecting diabetic microangiopathy, assessing the prognosis of foot ulcers, and diagnosing the osteomyelitis

  11. Development of gamma-photon/Cerenkov-light hybrid system for simultaneous imaging of I-131 radionuclide

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi; Suzuki, Mayumi; Kato, Katsuhiko [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan); Ogata, Yoshimune [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan)

    2016-09-11

    Although iodine 131 (I-131) is used for radionuclide therapy, high resolution images are difficult to obtain with conventional gamma cameras because of the high energy of I-131 gamma photons (364 keV). Cerenkov-light imaging is a possible method for beta emitting radionuclides, and I-131 (606 MeV maximum beta energy) is a candidate to obtain high resolution images. We developed a high energy gamma camera system for I-131 radionuclide and combined it with a Cerenkov-light imaging system to form a gamma-photon/Cerenkov-light hybrid imaging system to compare the simultaneously measured images of these two modalities. The high energy gamma imaging detector used 0.85-mm×0.85-mm×10-mm thick GAGG scintillator pixels arranged in a 44×44 matrix with a 0.1-mm thick reflector and optical coupled to a Hamamatsu 2 in. square position sensitive photomultiplier tube (PSPMT: H12700 MOD). The gamma imaging detector was encased in a 2 cm thick tungsten shield, and a pinhole collimator was mounted on its top to form a gamma camera system. The Cerenkov-light imaging system was made of a high sensitivity cooled CCD camera. The Cerenkov-light imaging system was combined with the gamma camera using optical mirrors to image the same area of the subject. With this configuration, we simultaneously imaged the gamma photons and the Cerenkov-light from I-131 in the subjects. The spatial resolution and sensitivity of the gamma camera system for I-131 were respectively ~3 mm FWHM and ~10 cps/MBq for the high sensitivity collimator at 10 cm from the collimator surface. The spatial resolution of the Cerenkov-light imaging system was 0.64 mm FWHM at 10 cm from the system surface. Thyroid phantom and rat images were successfully obtained with the developed gamma-photon/Cerenkov-light hybrid imaging system, allowing direct comparison of these two modalities. Our developed gamma-photon/Cerenkov-light hybrid imaging system will be useful to evaluate the advantages and disadvantages of these two

  12. Feasibility of dual radionuclide brain imaging with I-123 and Tc-99m

    International Nuclear Information System (INIS)

    Ivanovic, M.; Weber, D.A.; Loncaric, S.; Franceschi, D.

    1994-01-01

    A study was conducted to evaluate the feasibility of simultaneous dual radionuclide brain imaging with 123 I and 99m Tc using photopeak image subtraction techniques or offset photopeak image acquisition. The contribution of the photons from one radionuclide to a second radionuclide's photopeak energy window (crosstalk) was evaluated for SPECT and planar imaging of a brain phantom containing 123 I and 99m Tc for a range of activity levels and distribution properties approximating those in rCBF images of the adult human brain. Crosstalk was evaluated for 10% symmetrical energy windows centered on the 123 I and 99m Tc photopeaks and for 10% energy windows asymmetrically placed to the left and right of the center of the respective photopeaks. It was observed that the centered photopeak windows, 99m Tc crosstalk in the 123 I window is 8.9% of the 99m Tc seen in the 99m Tc window and ranges from 37.5% to 75.0% of the 123 I in the 123 I window. 123 I crosstalk is 37.8% of the 123 I seen in the 123 I window and ranges from 4.4% to 8.9% of the 99m Tc seen in the 99m Tc window. The spatial distribution of a radionuclide's crosstalk photons differs from that observed in the radionuclide's photopeak window. A 99m Tc photopeak window offset to the left does not decrease 123 I crosstalk, and the percentage of 99m Tc scattered photons is significantly increased in the window. Offsetting the 123 I window to the right decreases 99m Tc crosstalk to 9.0% to 17.9% of the 123 I counts, but decreases 123 I sensitivity by 39.9%. Offsetting both photopeak windows to the right decreases the 99m Tc scattered photons in the 99m Tc window, but increases 123 I crosstalk to 17.0% to 33.8% of the 99m Tc counts

  13. Radionuclide reporter gene imaging for cardiac gene therapy

    International Nuclear Information System (INIS)

    Inubushi, Masayuki; Tamaki, Nagara

    2007-01-01

    In the field of cardiac gene therapy, angiogenic gene therapy has been most extensively investigated. The first clinical trial of cardiac angiogenic gene therapy was reported in 1998, and at the peak, more than 20 clinical trial protocols were under evaluation. However, most trials have ceased owing to the lack of decisive proof of therapeutic effects and the potential risks of viral vectors. In order to further advance cardiac angiogenic gene therapy, remaining open issues need to be resolved: there needs to be improvement of gene transfer methods, regulation of gene expression, development of much safer vectors and optimisation of therapeutic genes. For these purposes, imaging of gene expression in living organisms is of great importance. In radionuclide reporter gene imaging, ''reporter genes'' transferred into cell nuclei encode for a protein that retains a complementary ''reporter probe'' of a positron or single-photon emitter; thus expression of the reporter genes can be imaged with positron emission tomography or single-photon emission computed tomography. Accordingly, in the setting of gene therapy, the location, magnitude and duration of the therapeutic gene co-expression with the reporter genes can be monitored non-invasively. In the near future, gene therapy may evolve into combination therapy with stem/progenitor cell transplantation, so-called cell-based gene therapy or gene-modified cell therapy. Radionuclide reporter gene imaging is now expected to contribute in providing evidence on the usefulness of this novel therapeutic approach, as well as in investigating the molecular mechanisms underlying neovascularisation and safety issues relevant to further progress in conventional gene therapy. (orig.)

  14. An experimental study on the application of radionuclide imaging in repair of the bone defect

    Directory of Open Access Journals (Sweden)

    Weimin Zhu

    2011-08-01

    Full Text Available The aim of our study was to validate the effect of radionuclide imaging in early monitoring of the bone’s reconstruction, the animal model of bone defect was made on the rabbits repaired with HA artificial bone. The ability of bone defect repair was evaluated by using radionuclide bone imaging at 2, 4, 8 and 12 weeks postoperatively. The results indicate that the experimental group stimulated more bone formation than that of the control group. The differences of the bone reconstruction ability were statistically significant (p<0.05. The nano-HA artificial has good bone conduction, and it can be used for the treatment of bone defects. Radionuclide imaging may be an effective and first choice method for the early monitoring of the bone’s reconstruction.

  15. Radionuclide imaging in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Karlin, C.A.; Robinson, R.G.; Hinthorn, D.R.; Liu, C.

    1978-01-01

    Eight patients with herpes simplex encephalitis among the 10 cases diagnosed at the University of Kansas Medical Center from 1966 to 1976 were studied with /sup 99m/Tc early in their diagnostic work-up. The images were unilaterally positive in the temporal lobe area in all 8 patients. Radionuclide studies can suggest herpes simplex as the specific etiology in cases of encephalitis and can also indicate the best site for brain biopsy to confirm the diagnosis by fluorescent antibody techniques. Appropriate antiviral therapy should be instituted as soon as possible to alter the course of this destructive form of viral encephalitis

  16. Stress injuries of the pars interarticularis: Radiologic classification and indications for radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pennell, R.; Maurer, A.R.; Bonakdarpour, A.

    1984-01-01

    Lumbar spine radiographs and radionuclide images were compared and correlated with clinical histories of 20 athletes with low back pain. Radiographs were classified as: Normal (Type 0); showing a healing stress fracture (an irregular lucent line) with sclerosis (Type I); as an evolving or healed stress injury with either sclerosis, narrowing, or demineralization (Type II); and as a chronic fracture showing a large lucency with well-defined margins classically referred to as spondylolysis (Type III). Patients were grouped clinically on the basis of their pain: acute onset (Group A, n = 7), acute superimposed on chronic (Group B, n = 9), and chronic pain without an acute event (Group C, n = 4). Radiographic abnormalities were present in 95% (19/20) of the patients and radionuclide studies were positive in 60% (12/20). Scintigraphy was positive most often with Type I pars abnormalities (77%, 10/13) and negative most often with Type III abnormalities (91%, 11/12). Of all positive scintigraphy 12/14 (86%) were in pts in Groups A and B (acute symptoms). The authors' findings support theories that radiographic pars abnormalities exist which correspond to stages in the healing of stress induced fractures. With acute symptoms radionuclide imaging need not be obtained if a Type I radiographic abnormality is seen. Radionuclide imaging is indicated with either Type 0, II or III radiographs to confirm or rule out recent stress injury.

  17. Stress injuries of the pars interarticularis: Radiologic classification and indications for radionuclide imaging

    International Nuclear Information System (INIS)

    Pennell, R.; Maurer, A.R.; Bonakdarpour, A.

    1984-01-01

    Lumbar spine radiographs and radionuclide images were compared and correlated with clinical histories of 20 athletes with low back pain. Radiographs were classified as: Normal (Type 0); showing a healing stress fracture (an irregular lucent line) with sclerosis (Type I); as an evolving or healed stress injury with either sclerosis, narrowing, or demineralization (Type II); and as a chronic fracture showing a large lucency with well-defined margins classically referred to as spondylolysis (Type III). Patients were grouped clinically on the basis of their pain: acute onset (Group A, n = 7), acute superimposed on chronic (Group B, n = 9), and chronic pain without an acute event (Group C, n = 4). Radiographic abnormalities were present in 95% (19/20) of the patients and radionuclide studies were positive in 60% (12/20). Scintigraphy was positive most often with Type I pars abnormalities (77%, 10/13) and negative most often with Type III abnormalities (91%, 11/12). Of all positive scintigraphy 12/14 (86%) were in pts in Groups A and B (acute symptoms). The authors' findings support theories that radiographic pars abnormalities exist which correspond to stages in the healing of stress induced fractures. With acute symptoms radionuclide imaging need not be obtained if a Type I radiographic abnormality is seen. Radionuclide imaging is indicated with either Type 0, II or III radiographs to confirm or rule out recent stress injury

  18. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  19. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  20. Medical imaging technology

    CERN Document Server

    Haidekker, Mark A

    2013-01-01

    Biomedical imaging is a relatively young discipline that started with Conrad Wilhelm Roentgen’s discovery of the x-ray in 1885. X-ray imaging was rapidly adopted in hospitals around the world. However, it was the advent of computerized data and image processing that made revolutionary new imaging modalities possible. Today, cross-sections and three-dimensional reconstructions of the organs inside the human body is possible with unprecedented speed, detail and quality. This book provides an introduction into the principles of image formation of key medical imaging modalities: X-ray projection imaging, x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, and radionuclide imaging. Recent developments in optical imaging are also covered. For each imaging modality, the introduction into the physical principles and sources of contrast is provided, followed by the methods of image formation, engineering aspects of the imaging devices, and a discussion of strengths and limitations of the modal...

  1. The clinical evaluation of combining radionuclide imaging with radioimmunoassay for hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Huang Chenggang; Chen Xiaoyan; Deng Yan

    2003-01-01

    By analysing nuclide image characteristics and radioimmunoassay data of 61 cases with Hashimoto's thyroiditis (HT), HT can be classified five types as below: uneven distribution, diffusion, with hyperfunction, with nodules, nearly normal. The results of radionuclide imaging and the radioimmunoassay of all the types indicate that HT can be preliminarily diagnosed by conscientiously analysing nuclide image characteristics and radioimmunoassay data and linking clinical symptoms and signs

  2. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  3. Using radionuclide imaging for monitoring repairment of bone defect with tissue-engineered bone graft in rabbits

    International Nuclear Information System (INIS)

    Xia Changsuo; Ye Fagang; Zou Yunwen; Ji Shixiang; Wang Dengchun

    2004-01-01

    Objective: To observe the effect of tissue-engineered bone grafts in repairing bone defect in rabbits, and assess the value of radionuclide for monitoring the therapeutic effect of this approach. Methods: Bilateral radial defects of 15 mm in length in 24 rabbits were made. The tissue-engineered bone grafts (composite graft) contained bone marrow stromal cells (BMSCs) of rabbits and calcium phosphate cement (CPC) were grafted in left side defects, CPC only grafts (artificial bone graft) in right defects. After the operation, radionuclide was used to monitor the therapeutic effects at 4, 8 and 12 weeks. Results: 99 Tc m -methylene diphosphonic acid (MDP) radionuclide bone imaging indicated that there was more radionuclide accumulation in grafting region of composite than that of CPC. There was significant difference between 99 Tc m -MDP uptake of the region of interest (ROI) and scintillant counts of composite bone and the artificial bone (P<0.01). Conclusion: Tissue-engineered bone grafts is eligible for repairing radial bone defects, and radionuclide imaging may accurately monitor the revascularization and bone regeneration after the bone graft implantation. (authors)

  4. Radionuclide imaging of infection: what the future holds

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, Christopher J. [Yeshiva University, NY (United States). Albert Einstein College of Medicine]. E-mail: palestro@lij.edu

    2008-12-15

    Nuclear Medicine plays an important role in the evaluation of patients suspected of harboring infection. Gallium imaging is especially useful for opportunistic infections and spinal osteomyelitis. In vitro labeled leukocyte imaging is the current radionuclide gold standard for imaging most infections, in immunocompetent patients, including cardiovascular, postoperative, and musculoskeletal infections (except spinal osteomyelitis). Several in-vivo leukocyte labeling methods have been investigated, but none are widely used. Results obtained with radiolabeled antibiotics have been disappointing. Data on FDG are still emerging, but this agent appears to be especially valuable in fever of unknown origin, spinal osteomyelitis, vasculitis and sarcoidosis. It is conceivable that in the near future, FDG-PET and PET/CT will replace gallium for many indications. Investigators also are studying ways to label leukocytes with positron emitters in order to combine the advantages of PET with those of labeled leukocytes. (author)

  5. Should single-phase radionuclide bone imaging be used in suspected osteomyelitis

    International Nuclear Information System (INIS)

    Fihn, S.D.; Larson, E.B.; Nelp, W.B.; Rudd, T.G.; Gerber, F.H.

    1984-01-01

    The records of 69 patients who had 86 delayed, static radionuclide bone images for suspected osteomyelitis were studied to determine the effects of this procedure on diagnosis and treatment. Sensitivity, specificity, and positive predictive value were lower than reported in several other studies. When osteomyelitis was unlikely, imaging was either negative or falsely positive and rarely affected treatment. In 46 cases where osteomyelitis was more likely, imaging potentially changed therapy in 19 but was unhelpful or misleading in 15. Static-phase images with ''definite'' interpretations, particularly when negative, are specific, but ''equivocal'' studies may lead to diagnostic and therapeutic errors. When ostemyelitis is improbable, imaging rarely changes diagnosis or therapy

  6. Radionuclide imaging of soft tissue neoplasms

    International Nuclear Information System (INIS)

    Chew, F.S.; Hudson, T.M.; Enneking, W.F.

    1981-01-01

    Two classes of radiopharmaceuticals may be used for imaging tumors of the musculoskeletal system. The first is comprised of soft tissue or tumor specific agents such as gallium-67, bleomycin, and radionuclide-labeled antibodies, which may be useful for detecting and localizing these tumors. The other class of tracer is comprised of those with avidity for bone. The 99mTc-labeled-phosphate skeletal imaging compounds have been found to localize in a variety of soft tissue lesions, including benign and malignant tumors. In 1972, Enneking began to include bone scans in the preoperative evaluation of soft tissue masses. Later, he and his associates reported that these scans were useful in planning operative treatment of sarcomas by detecting involvement of bone by the tumors. Nearly all malignant soft tissue tumors take up bone-seeking radiopharmaceuticals, and bone involvement was indicated in two-thirds of the scans we reviewed. About half of benign soft tissue lesions had normal scans, but the other half showed uptake within the lesion and a few also showed bone involvement. Careful, thorough imaging technique is essential to proper evaluation. Multiple, high-resolution static gamma camera images in different projections are necessary to adequately demonstrate the presence or absence of soft tissue abnormality and to define the precise relationship of the tumor to the adjacent bone

  7. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator

    International Nuclear Information System (INIS)

    Du, Yong; Frey, Eric C; Bhattacharya, Manojeet

    2014-01-01

    Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter

  8. Three-phase radionuclide bone imaging in sports medicine

    International Nuclear Information System (INIS)

    Rupani, H.D.; Holder, L.E.; Espinola, D.A.; Engin, S.I.

    1985-01-01

    Three-phase radionuclide bone (TPB) imaging was performed on 238 patients with sports-related injuries. A wide variety of lesions was encountered, but the most frequent lesions seen were stress fractures of the lower part of the leg at the junction of the middle and distal thirds of the posterior tibial cortex (42 of 79 lesions). There were no differences in the type, location, or distribution of lesions between males and females or between competitive and noncompetitive athletes. In 110 cases, bone stress lesions were often diagnosed when radiographs were normal, whereas subacute or chronic soft-tissue abnormalities had few specific scintigraphic features. TPB imaging provides significant early diagnostic information about bone stress lesions. Normal examination results (53 cases) exclude underlying osseous pathologic conditions

  9. Sequential radionuclide bone imaging in avascular pediatric hip conditions

    International Nuclear Information System (INIS)

    Minikel, J.; Sty, J.; Simons, G.

    1983-01-01

    Radionuclide bone imaging was performed on six patients with various hip conditions. Initial bone images revealed diminished uptake of isotope /sup 99m/Tc-MDP in the capital femoral epiphysis. Following therapeutic intervention, repeat bone scans revealed normal uptake of /sup 99m/Tc-MDP in the capital femoral epiphysis. Subsequent radiographs revealed that avascular necrosis had not occurred. There are two types of avascularity: the potentially reversible, and the irreversible. Attempts should be made toward early recognition of the potentially reversible avascular insult. With early recognition, surgical reconstruction prior to osteophyte death may result in revascularization. If this can be accomplished, avascular necrosis can be avoided

  10. Hanford Waste Vitrification Plant technical background document for best available radionuclide control technology demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, A.B.; Skone, S.S.; Rodenhizer, D.G.; Marusich, M.V. (Ebasco Services, Inc., Bellevue, WA (USA))

    1990-10-01

    This report provides the background documentation to support applications for approval to construct and operate new radionuclide emission sources at the Hanford Waste Vitrification Plant (HWVP) near Richland, Washington. The HWVP is required to obtain permits under federal and state statutes for atmospheric discharges of radionuclides. Since these permits must be issued prior to construction of the facility, draft permit applications are being prepared, as well as documentation to support these permits. This report addresses the applicable requirements and demonstrates that the preferred design meets energy, environmental, and economic criteria for Best Available Radionuclide Control Technology (BARCT) at HWVP. 22 refs., 11 figs., 25 tabs.

  11. Hanford Waste Vitrification Plant technical background document for best available radionuclide control technology demonstration

    International Nuclear Information System (INIS)

    Carpenter, A.B.; Skone, S.S.; Rodenhizer, D.G.; Marusich, M.V.

    1990-10-01

    This report provides the background documentation to support applications for approval to construct and operate new radionuclide emission sources at the Hanford Waste Vitrification Plant (HWVP) near Richland, Washington. The HWVP is required to obtain permits under federal and state statutes for atmospheric discharges of radionuclides. Since these permits must be issued prior to construction of the facility, draft permit applications are being prepared, as well as documentation to support these permits. This report addresses the applicable requirements and demonstrates that the preferred design meets energy, environmental, and economic criteria for Best Available Radionuclide Control Technology (BARCT) at HWVP. 22 refs., 11 figs., 25 tabs

  12. Differential diagnostic features of the radionuclide scrotal image

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1977-01-01

    Differential diagnosis of scrotal lesions is aided by correlating radionuclide images with clinical findings. Subacute torsion is associated with peripheral hyperemia and can be mistaken for an inflammatory process; however, in a review of 128 studies, torsion and orchiectomy were the only processes encountered which had a center truly devoid of activity on the tissue phase compared to the normal side. Other lesions such as acute inflammation, abscess, hematoma, and hemorrhagic tumor may superficially appear to lack central activity but invariably contain at least as much activity when compared to the normal side.

  13. Differential diagnostic features of the radionuclide scrotal image

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1977-01-01

    Differential diagnosis of scrotal lesions is aided by correlating radionuclide images with clinical findings. Subacute torsion is associated with peripheral hyperemia and can be mistaken for an inflammatory process; however, in a review of 128 studies, torsion and orchiectomy were the only processes encountered which had a center truly devoid of activity on the tissue phase compared to the normal side. Other lesions such as acute inflammation, abscess, hematoma, and hemorrhagic tumor may superficially appear to lack central activity but invariably contain at least as much activity when compared to the normal side

  14. A Monte Carlo study on {sup 223}Ra imaging for unsealed radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Miwa, Kenta; Sasaki, Masayuki [Faculty of Medical Sciences, Department of Health Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1, Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2016-06-15

    Purpose: Radium-223 ({sup 223}Ra), an α-emitting radionuclide, is used in unsealed radionuclide therapy for metastatic bone tumors. The demand for qualitative {sup 223}Ra imaging is growing to optimize dosimetry. The authors simulated {sup 223}Ra imaging using an in-house Monte Carlo simulation code and investigated the feasibility and utility of {sup 223}Ra imaging. Methods: The Monte Carlo code comprises two modules, HEXAGON and NAI. The HEXAGON code simulates the photon and electron interactions in the tissues and collimator, and the NAI code simulates the response of the NaI detector system. A 3D numeric phantom created using computed tomography images of a chest phantom was installed in the HEXAGON code. {sup 223}Ra accumulated in a part of the spine, and three x-rays and 19 γ rays between 80 and 450 keV were selected as the emitted photons. To evaluate the quality of the {sup 223}Ra imaging, the authors also simulated technetium-99m ({sup 99m}Tc) imaging under the same conditions and compared the results. Results: The sensitivities of the three photopeaks were 147 counts per unit of source activity (cps MBq{sup −1}; photopeak: 84 keV, full width of energy window: 20%), 166 cps MBq{sup −1} (154 keV, 15%), and 158 cps MBq{sup −1} (270 keV, 10%) for a low-energy general-purpose (LEGP) collimator, and those for the medium-energy general-purpose (MEGP) collimator were 33, 13, and 8.0 cps MBq{sup −1}, respectively. In the case of {sup 99m}Tc, the sensitivity was 55 cps MBq{sup −1} (141 keV, 20%) for LEGP and 52 cps MBq{sup −1} for MEGP. The fractions of unscattered photons of the total photons reflecting the image quality were 0.09 (84 keV), 0.03 (154 keV), and 0.02 (270 keV) for the LEGP collimator and 0.41, 0.25, and 0.50 for the MEGP collimator, respectively. Conversely, this fraction was approximately 0.65 for the simulated {sup 99m}Tc imaging. The sensitivity with the LEGP collimator appeared very high. However, almost all of the counts were

  15. Radionuclide imaging of the painful joint replacement: past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, Christopher J. [Long Island Jewish Medical Center, New Hyde Park, NY (United States)]. E-mail: palestro@lij.edu

    2002-09-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  16. Radionuclide imaging of the painful joint replacement: past, present and future

    International Nuclear Information System (INIS)

    Palestro, Christopher J.

    2002-01-01

    Differentiating aseptic loosening from infection as the cause of prosthetic joint failure is difficult because both entities are similar, clinically and histopathologically. Aseptic loosening frequently result from an immune reaction to the prosthesis. There is inflammation with an influx of histiocytes, giant cells, lymphocytes and plasma cells. Pro inflammatory cytokines and proteolytic enzymes are secreted, causing osteolysis and loosening. These same events occur in infection except that neutrophils, rarely present in aseptic loosening, area invariably present in infection. Clinical signs and symptoms, laboratory tests, X-rays and joint aspiration are insensitive, nonspecific or both. Artifacts produced by the metallic hardware hamper cross-sectional imaging modalities. Radionuclide imaging is not affected by the presence of metallic hardware and is very useful for evaluating the painful prosthesis. Bone scintigraphy, with and accuracy of 50%-70% is a useful screening test, since a normal study effectively excludes a prosthetic complication. Adding gallium-67, a nonspecific inflammation-imaging agent, improves the accuracy of bone scintigraphy to 70%-80%. The accuracy of combined leukocyte/marrow imaging, 90%, is the highest among available radionuclide studies. Its success is due to the fact that leukocytes imaging is most sensitive for detecting neutrophil mediated inflammations. Inflammatory conditions that are neutrophil-poor, even though large numbers of other leukocytes may be present, (such as the aseptically loosened joint prosthesis) go undetected. The success of leukocyte/marrow imaging is tempered by the limitations of in vitro labeling. In vivo labeling has been investigated and a murine monoclonal anti-granulocyte antibody appears promising. Some investigations have focused on F-18 FDG imaging, although specificity is a concern with this agent. (author)

  17. History of medical radionuclide production.

    Science.gov (United States)

    Ice, R D

    1995-11-01

    Radionuclide production for medical use originally was incidental to isotope discoveries by physicists and chemists. Once the available radionuclides were identified they were evaluated for potential medical use. Hevesy first used 32P in 1935 to study phosphorous metabolism in rats. Since that time, the development of cyclotrons, linear accelerators, and nuclear reactors have produced hundreds of radionuclides for potential medical use. The history of medical radionuclide production represents an evolutionary, interdisciplinary development of applied nuclear technology. Today the technology is represented by a mature industry and provides medical benefits to millions of patients annually.

  18. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Institute of Scientific and Technical Information of China (English)

    Jean-Fran?ois Sarrazin; Fran?ois Philippon; Mika?l Trottier; Michel Tessier

    2016-01-01

    Cardiovascular implantable electronic device(CIED) infection and prosthetic valve endocarditis(PVE) remain a diagnostic challenge.Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE.Over the past few years,cardiac radionuclide imaging has gained a key role in the diagnosis of these patients,and in assessing the need for surgery,mainly in the most difficult cases.Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography(WBC SPECT/CT) have been studied in these situations.In their 2015 guidelines for the management of infective endocarditis,the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE,but not CIED infection since the data were judged insufficient at the moment.This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE,and describes the technical aspects of cardiac radionuclide imaging.It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE,the limitations of these tests,and potential areas of future research.

  19. Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

    Science.gov (United States)

    Sarrazin, Jean-François; Philippon, François; Trottier, Mikaël; Tessier, Michel

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, mainly in the most difficult cases. Both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) and radiolabelled white blood cell single-photon emission computed tomography/computed tomography (WBC SPECT/CT) have been studied in these situations. In their 2015 guidelines for the management of infective endocarditis, the European Society of Cardiology incorporated cardiac nuclear imaging as part of their diagnostic algorithm for PVE, but not CIED infection since the data were judged insufficient at the moment. This article reviews the actual knowledge and recent studies on the use of 18F-FDG PET/CT and WBC SPECT/CT in the context of CIED infection and PVE, and describes the technical aspects of cardiac radionuclide imaging. It also discusses their accepted and potential indications for the diagnosis and management of CIED infection and PVE, the limitations of these tests, and potential areas of future research. PMID:27721936

  20. Radionuclide techniques for brain imaging

    International Nuclear Information System (INIS)

    Cowan, R.J.; Moody, D.M.

    1984-01-01

    Over the past decade, many of the prime indications for radionuclide brain scanning have become instead indications for CCT, and nuclear medicine studies of the brain have assumed more of a complementary, supportive role. However, there is great promise for improvement in central nervous system radionuclide applications with advances anticipated in both radiopharmaceuticals and instrumentation. Nuclear medicine is continuing to function as a powerful research tool and, in the relatively near future, may regain its role as a major clinical test of the central nervous system

  1. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1981-03-03

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.

  2. Radioanalytical technology for 10 CFR Part 61 and other selected radionuclides: Literature review

    International Nuclear Information System (INIS)

    Thomas, C.W.; Thomas, V.W.; Robertson, D.E.

    1996-03-01

    A comprehensive literature review and assessment was conducted to identify and evaluate radioanalytical technology and procedures used for measuring 10CFR61 radionuclides and other long-lived isotopes. This review evaluated radiochemical procedures currently in use at a number of laboratories in the US, as well as identifying new advanced methods and techniques which could be adapted for routine radiochemical analyses of low-level radioactive waste. The 10CFR61 radionuclides include 14 C, 60 Cl, 59,63 Ni, 90 Sr, 94 Nb, 99 Tc, 129 I, 137 Cs, and TRU isotopes with half lives greater than 5 years. Other low-level radionuclides of interest include 7,10 Be, 26 Al, 36 Cl, 93 Mo, 109,113m Cd, and 121m,126 Sn, which may be present in various types of waste streams from nuclear power stations

  3. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  4. Remediation of radionuclide pollutants through biosorption - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Das, Nilanjana [Environmental Biotechnology Division, School of Biosciences and Technology, VIT University, Vellore (India)

    2012-01-15

    The development of nuclear science and technology has led to the increase of nuclear wastes containing radionuclides to be released and disposed in the environment. Pollution caused by radionuclides is a serious problem throughout the world. To solve the problem, substantial research efforts have been directed worldwide to adopt sustainable technologies for the treatment of radionuclide containing wastes. Biosorption represents a technological innovation as well as a cost effective excellent remediation technology for cleaning up radionuclides from aqueous environment. A variety of biomaterials viz. algae, fungi, bacteria, plant biomass, etc. have been reported for radionuclide remediation with encouraging results. This paper reviews the achievements and current status of radionuclide remediation through biosorption which will provide insights into this research frontier. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Transfer of fallout radionuclides derived from Fukushima NPP accident: 1 year study on transfer of radionuclides through hydrological processes

    Science.gov (United States)

    Onda, Yuichi; Kato, Hiroaki; Patin, Jeremy; Yoshimura, Kazuya; Tsujimura, Maki; Wakahara, Taeko; Fukushima, Takehiko

    2013-04-01

    Previous experiences such as Chernobyl Nuclear Power Plant accident have confirmed that fallout radionuclides on the ground surface migrate through natural environment including soils and rivers. Therefore, in order to estimate future changes in radionuclide deposition, migration process of radionuclides in forests, soils, ground water, rivers should be monitored. However, such comprehensive studies on migration through forests, soils, ground water and rivers have not been conducted so far. Here, we present the following comprehensive investigation was conducted to confirm migration of radionuclides through natural environment including soils and rivers. 1)Study on depth distribution of radiocaesium in soils within forests, fields, and grassland 2)Confirmation of radionuclide distribution and investigation on migration in forests 3)Study on radionuclide migration due to soil erosion under different land use 4)Measurement of radionuclides entrained from natural environment including forests and soils 5)Investigation on radionuclide migration through soil water, ground water, stream water, spring water under different land use 6)Study on paddy-to-river transfer of radionuclides through suspended sediments 7)Study on river-to-ocean transfer of radionuclides via suspended sediments 8)Confirmation of radionuclide deposition in ponds and reservoirs

  6. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT

    DEFF Research Database (Denmark)

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated ...

  7. Dental diseases and radionuclide imaging of the jaws.

    Science.gov (United States)

    Arias, Jose A; Pardo, Carlos; Olmos, Antonio; Cuadrado, Maria L; Ruibal, Alvaro

    2004-03-01

    The aim of this study was to compare the results of radionuclide bone scans of the jaws with data obtained at the nuclear medicine department from a brief and feasible dental history, taking special account of cases with a positive scan and no recent dental events. Ninety-eight patients undergoing radionuclide bone scan as part of their diagnosis in non-dental, oncological and non-oncological diseases were imaged with 99mTc-labelled oxidronate. Superior and inferior halves of the mandible and maxilla (392 quadrants) were regarded as normal or having an abnormally high uptake. A recent (1 year) dental history was also obtained through a brief questionnaire and data were referred to each quadrant of the jaws. The association between the bone scan and dental disease was assessed by means of the chi-squared test. The overall results of scintigraphy and history coincided in 66 patients (46 with abnormal and 20 with normal findings; P = 0.002). Twenty-five patients had a positive scintigram without any known dental disorder. Results of scintigraphy and history coincided in 254 quadrants (78 with abnormal and 176 with normal findings; P < 0.001). Eighty-three quadrants had hot spots in the scintigram without any known dental lesion. It can be concluded that abnormal jaw scintigrams are frequent in patients without known dental disease, and this may indicate silent osteoblastic activity. These observations should be reported to the dentist for several reasons. First, they may reveal asymptomatic dental lesions. Second, the use of oral prostheses and implants is increasing and they require the support of healthy alveolar bone.

  8. Central nervous system imaging

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Since its introduction in 1973, computed tomography (CT) of the brain has had a revolutionary impact on neuroradiologic diagnosis. It has largely replaced radionuclide brain imaging as the initial, noninvasive neurologic screening examination. Although conventional radionuclide brain imaging still contributes useful and unique diagnostic information in a few clinical situations, it appears that new technology and applications must be found if nuclear imaging is to play a prominent future role in neurologic diagnosis as it did in the past. One of the main advantages of CT over radionuclide brain imaging at present is CT's ability to demonstrate the size, shape, and position of the cerebral ventricles and subarachnoid spaces. Another important strength of CT is the ability to differentiate ischemic cerebral infarction from intracerebral hemorrhage. The overall sensitivity of CT in detecting intracranial neoplasms is also greater than that of radionuclide brain imaging, and CT is very useful in demonstrating the effects of head trauma. Magnetic resonance imaging appears superior to CT in the evaluation of neurologic disorders. A renewed interest in radionuclide brain imaging has developed because of recent advances in emission computed tomographic imaging. When tracer kinetic models are used, cerebral blood flow (CBF), blood volume, metabolic rate, and glucose and amino acid transport can be measured. Other applications involve investigation of receptor bindings, evaluation of the blood-brain barrier, brain blood-volume measurement, and cisternography

  9. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  10. Testicular radionuclide angiography and sttatic imaging: anatomy, scintigraphic interpretation, and clinical indications

    International Nuclear Information System (INIS)

    Holder, L.E.; Martire, J.R.; Holmes, E.R. III.; Wagner, H.N. Jr.

    1977-01-01

    Radionuclide testicular angiography and static imaging is an easy, rapidly performed study. Its usefulness in separating acute testicular torsion from acute epididymitis has been confirmed. Increased angiographic perfusion with definition of the testicular and deferential arteries in the spermatic cord and the pudendal artery posteriorly is equated with inflammation. Intense increased vascularity on the blood pool image is seen in abscess and acute inflammation, while cases of tumor and trauma have mild increases. Acute or missed testicular torsion, uncomplicated hydroceles, and spermatoceles show absent vascularity. On the static images, decreased activity is characteristic of the shape and location of the avascular structure. Technical factors are stressed

  11. Use of radionuclide imaging in the early diagnosis and treatment of renal allograft rejection

    International Nuclear Information System (INIS)

    Mandel, S.R.; Mattern, W.D.; Staab, E.; Johnson, G. Jr.

    1975-01-01

    Data are presented on the clinical application of radionuclide imaging to evaluate changes in cadaver transplant function in the immediate postoperative period. The method uses orthoiodohippuric acid (hippuran) administered IV, with scintillation imaging, and curve analysis by a digital computer. An initial study is always obtained 24 hours after transplantation. Serial studies are then obtained, as needed, to interpret the clinical course. Selected cases are presented which illustrate the use of this protocol in various clinical settings. In the oliguric patient serial studies have been of particular value. They have identified ATN so that overenthusiastic treatment for rejection could be avoided. They have also identified acute rejection complicating ATN so that high dose steroid therapy could be administered appropriately. In the nonoliguric patient they have frequently contributed to the early diagnosis of acute rejection, and they have been useful in monitoring the effect and duration of treatment for severe rejection crisis. It is concluded that radionuclide imaging studies, when carefully applied and interpreted, are a valuable adjunct to the management of patients in this complex clinical setting

  12. Analysis of cardiac images of radionuclide ventriculography in AT-Type personal computer

    International Nuclear Information System (INIS)

    Lillo, R.; Gonzalez, P.; Ehijo, A.; Otarola, T.M.S.; Ortiz, M.; Silva, A.M.; Ortiz, M.

    1990-01-01

    The goal of this research was to produce software for the processing of Cardiac Phase images in personal computers. The results of standard radionuclide Ventriculography and Fourier analysis, got on gamma camera Ohio Nuclear 410 Sygma and Digital PDP 11/34 computer were coded into ASCII file and then transfered via Smarterm 220/Kermit to an Accel 900 AT PC. After decoding the images they were processed with a program develope in C Lenguaje obtaining the values of Phase Angles in the whole phase images and in regions of interest drawn around the cardiac chambers. The images and values were the same as those obtained by conventional processing in the PDP 11/34 computer. This is considered a first stage for the use of PC to Nuclear Medicine imaging studies. (author)

  13. Early detection of Freiberg's disease by radionuclide bone imaging

    International Nuclear Information System (INIS)

    Peng Jingjing

    1993-01-01

    56 hallux valgus deformities of 28 patients were studied with radionuclide bone imaging (RNBI). Among them, 24 feet(42.85%) revealed increased uptake of radioactivity in second or third metatarsal. The ratio of radioactivity in lesion and contralateral normal site (D/N) was increased, the difference between the patient and normal groups was significant (P<0.01). The histologic study showed that there have been degenerative changes and bone cell necrosis in increased uptake area. It was concluded that RNBI was more sensitive than X ray and can be used for the early diagnosis of Freiberg's Disease

  14. Radionuclide technology applications in development and production in the automobile industry

    International Nuclear Information System (INIS)

    Sailer, S.

    1982-01-01

    Radionuclide technology (RNT) is utilized for air-engineering measurements. The spheres of interest here are the magnitude of the air flow and its spatial distribution in the interior of passenger cars, truck cabs and buses. For this purpose the air inside the vehicle is marked with 85 Kr, and the decrease in activity is measured at various driving speeds simulated in a wind tunnel. Oil consumption measurements with tritium-marked motor oil are used primarily to optimize new engines in terms of design (e.g. piston-ring components, type of lubrication), materials and lubricants. For this purpose the oil consumption is measured under various engine operating conditions (oil-consumption performance graph). The oil consumption of the individual cylinders can also be measured. The effect of production technologies (e.g. form and surface perfection) on oil consumption is important for improving production. The radionuclide technique most often used in the automobile industry is for the measurement of wear. The focal point here is the optimization of tribological systems in the development of engines, transmissions etc., studying the influence of design, materials and lubricants and determining the operating conditions which are critical for wear. Important information regarding the influence of production technologies on wear can be gained for production. In addition, considerable savings and higher quality can be realized in production by optimization of engine run-in programmes with RNT. The common factors for all RNT processes mentioned are that, compared with conventional measuring procedures, they are more precise, require shorter testing times, and can be performed under normal operating conditions. The prerequisites are careful selection of the applications and continual optimization of measurement technology. (author)

  15. THERANOSTICS: From Molecular Imaging Using Ga-68 Labeled Tracers and PET/CT to Personalized Radionuclide Therapy - The Bad Berka Experience.

    Science.gov (United States)

    Baum, Richard P; Kulkarni, Harshad R

    2012-01-01

    The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET), single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs) using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT), and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction.

  16. [Preparation, quality control and thyroid molecule imaging of solid-target based radionuclide ioine-124].

    Science.gov (United States)

    Zhu, H; Wang, F; Guo, X Y; Li, L Q; Duan, D B; Liu, Z B; Yang, Z

    2018-04-18

    To provide useful information for the further production and application of this novel radio-nuclide for potential clinical application. 124 Te (p,n) 124 I nuclide reaction was used for the 124 I production. Firstly, the target material, 124 TeO 2 (200 mg) and Al2O3 (30 mg) mixture, were compressed into the round platinum based solid target by tablet device. HM-20 medical cyclotron was applied to irradiate the solid target slice for 6-10 h with helium and water cooling. Then, the radiated solid target was placed for 12 h (overnight) to decay the radioactive impurity; finally, 124 I was be purified by dry distillation using 1 mL/min nitrogen for about 6 hours and radiochemical separation methods. Micro-PET imaging studies were performed to investigate the metabolism properties and thyroid imaging ability of 124 I.After 740 kBq 124 I was injected intravenously into the tail vein of the normal mice, the animals were imaged with micro-PET and infused with CT. The micro-PET/CT infusion imaging revealed actual state 124 I's metabolism in the mice. It was been successfully applied for 200 mg 124 TeO 2 plating by the tablet device on the surface of platinum. It showed smooth, dense surface and without obviously pits and cracks. The enriched 124 Te target was irradiated for 6 to 10 hours at about 12.0 MeV with 20 μA current on HM-20 cyclotron. Then 370-1 110 MBq 124 I could be produced on the solid target after irradiation and 370-740 MBq high specific activity could be collected afterdry distillation separation and radio-chemical purification. 124 I product was finally dissolved in 0.01 mol/L NaOH for the future distribution. The gamma spectrum of the produced 124 I-solution showed that radionuclide purity was over 80.0%. The micro-PET imaging of 124 I in the normal mice exhibited the thyroid and stomach accumulations and kidney metabolism, the bladder could also be clearly visible, which was in accordance with what was previously reported. To the best of our knowledge

  17. Applications of radionuclide myocardial perfusion imaging in acute coronary syndrome

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin

    2008-01-01

    In recent years, acute coronary syndrome(ACS) has been getting more and more attentions. Radionuclide myocardial perfusion imaging (MPI) can make a quick accurate diagnosis for patients with acute chest pain who cann't be diagnosed by conventional methods. The sensitivity and negative predictive value of MPI are relatively high. Besides, MPI can be applicated in the detection of ischemic and infarct size and degree, the risk stratification and the assessment of prognosis of the patients with ACS, and the appraisal of the effect of strategies. (authors)

  18. Comparative analysis of radionuclide inhalation and perfusion lung imaging with X ray pulmonary angiography for the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Zhang Yanyan; Chen Man; Shao Maogang; Zhang Songlin; Mao Jieming; Guo Jingxuan

    1993-01-01

    The result of radionuclide lung imaging was compared in 18 patients of pulmonary embolism (PE) and 2 normal persons. The discovered perfusion defects correlated well with the location of angiographic obstruction. The positive angiographic and radionuclide finding was in 141 and 104 emboli arteries respectively. The sensitivity of total emboli pulmonary segments of lung imaging was 73.8%, the specificity was 82.7 and the accuracy was 79%. The techniques correlated quite well (r = 0.83, P<0.001)

  19. Radionuclide Therapies in Molecular Imaging and Precision Medicine.

    Science.gov (United States)

    Kendi, A Tuba; Moncayo, Valeria M; Nye, Jonathon A; Galt, James R; Halkar, Raghuveer; Schuster, David M

    2017-01-01

    This article reviews recent advances and applications of radionuclide therapy. Individualized precision medicine, new treatments, and the evolving role of radionuclide therapy are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Present status and problems of radionuclide studies in emergency cases

    International Nuclear Information System (INIS)

    Ogawa, Kiyoshi

    1983-01-01

    Scintigraphy is just right for diagnosing emergency cases due to its noninvasive and simple method, but emergency radionuclide studies have not become practical as a result of difficulty problems. Recently, nuclear medical devices have become easier to use in operations. It is become of this, that I have submitted this report regarding the problems of radionuclide studies in emergency cases. There were 101 cases (1.4 %) out of 7,310 cases for the year period Sept. 1981 - Aug. 1982. The studies consisted of 12 brain imaging cases, 9 plumonary imaging cases, 22 cardiac study cases (cardio-angiography cases 8, 99m-Tc-PYP myocardium imaging cases 12, 201-Tl myocardium imaging cases 2), 12 renal study cases, 11 G.I. blood loss cases, 35 peripheral angiography cases. In the near future, we will have to be ready to perform emergency radionuclide studies if the need arises. (author)

  1. Radionuclides: Accumulation and Transport in Plants.

    Science.gov (United States)

    Gupta, D K; Chatterjee, S; Datta, S; Voronina, A V; Walther, C

    Application of radioactive elements or radionuclides for anthropogenic use is a widespread phenomenon nowadays. Radionuclides undergo radioactive decays releasing ionizing radiation like gamma ray(s) and/or alpha or beta particles that can displace electrons in the living matter (like in DNA) and disturb its function. Radionuclides are highly hazardous pollutants of considerable impact on the environment, food chain and human health. Cleaning up of the contaminated environment through plants is a promising technology where the rhizosphere may play an important role. Plants belonging to the families of Brassicaceae, Papilionaceae, Caryophyllaceae, Poaceae, and Asteraceae are most important in this respect and offer the largest potential for heavy metal phytoremediation. Plants like Lactuca sativa L., Silybum marianum Gaertn., Centaurea cyanus L., Carthamus tinctorius L., Helianthus annuus and H. tuberosus are also important plants for heavy metal phytoremediation. However, transfer factors (TF) of radionuclide from soil/water to plant ([Radionuclide]plant/[Radionuclide]soil) vary widely in different plants. Rhizosphere, rhizobacteria and varied metal transporters like NRAMP, ZIP families CDF, ATPases (HMAs) family like P1B-ATPases, are involved in the radio-phytoremediation processes. This review will discuss recent advancements and potential application of plants for radionuclide removal from the environment.

  2. Biomedical research and application utilizing cyclotron produced radionuclides. Progress report, January 1 1977--December 31, 1977

    International Nuclear Information System (INIS)

    Laughlin, J.S.; Benua, R.S.; Tilbury, R.S.

    1977-01-01

    Progress is reported on cyclotron production of short-lived positron-emitting radionuclides ( 18 F, 15 O, 11 C, 13 N, 52 Fe, 38 K, 206 Bi, 73 Se, and 48 Cr) for use in the preparation labelled compounds for metabolic research in patients and animals. The chemical preparation of radiopharmaceuticals labelled with cyclotron-produced radionuclides for pancreas and tumor scanning is discussed. The imaging capabilities of a total organ kinetic imaging monitor (TOKIM) gamma camera system operated in the positron coincidence mode were improved with the addition of computerized iterative correction procedures

  3. THERANOSTICS: From Molecular Imaging Using Ga-68 Labeled Tracers and PET/CT to Personalized Radionuclide Therapy - The Bad Berka Experience

    Directory of Open Access Journals (Sweden)

    Richard P. Baum, Harshad R. Kulkarni

    2012-01-01

    Full Text Available The acronym THERANOSTICS epitomizes the inseparability of diagnosis and therapy, the pillars of medicine and takes into account personalized management of disease for a specific patient. Molecular phenotypes of neoplasms can be determined by molecular imaging with specific probes using positron emission tomography (PET, single photon emission computed tomography (SPECT, magnetic resonance imaging (MRI, or optical methods, so that the treatment is specifically targeted against the tumor and its environment. To meet these demands, we need to define the targets, ligands, coupling and labeling chemistry, the most appropriate radionuclides, biodistribution modifiers, and finally select the right patients for the personalized treatment. THERANOSTICS of neuroendocrine tumors (NETs using Ga-68 labeled tracers for diagnostics with positron emission tomography/ computed tomography (PET/CT, and using Lu-177 or other metallic radionuclides for radionuclide therapy by applying the same peptide proves that personalized radionuclide therapy today is already a fact and not a fiction.

  4. MR imaging of avascular necrosis of the femoral head: Correlation with radiography, radionuclide scan and clinical finding

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Woo, Young Hoon; Joo, Yang Goo; Lee, Sung Moon; Zeon, Seok Kil; Suh, Soo Jhi; Kang, Chang Soo [School of Medicine, Keimyung University, Taegu (Korea, Republic of)

    1992-03-15

    To explore the ability of magnetic resonance imaging(MRI) in the diagnosis of avascular necrosis(AVN) of the femoral head, we compared appearances on MRI of 85 proven AVN lesions with those on radiographs(n=79) and radionuclide scans(n=75). Clinical symptoms(n=85) were also correlated. All MR studies included coronal and axial T1WI and coronal T2WI. All lesions involved the anterosuperterior aspect of the femoral head and were surrounded by a low signal intensity rim on both T1 and T2WI. The signal intensity of the lesions was variable depending on the disease course, and the lesions were divided into four classes according to the classification suggested by Mitchell. Radiographs were normal in 16%(13/79) of the lesions which were in MR class A(10), B(1), C(2). The radionuclide scans showed normal in 16%(12/75) of the lesions which were in MR class A(8). B(1), C(2), D(1). On the other hand, 93% of the lesions with MR class A(27/29) showed stage 1 and 2 lesions on radiographs. Clinical symptoms were absent in 25%(21/85) of the lesions, and among these,81%(17/21) were MR class A. Conclusively, MR is superior to the radiography and radionuclide scan in the early detection of AVN, and can also show the exact location, extent and signal characteristic of the lesion. Therefore, Mr is essential in diagnosis and management of AVN.

  5. MR imaging of avascular necrosis of the femoral head: Correlation with radiography, radionuclide scan and clinical finding

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Woo, Young Hoon; Joo, Yang Goo; Lee, Sung Moon; Zeon, Seok Kil; Suh, Soo Jhi; Kang, Chang Soo

    1992-01-01

    To explore the ability of magnetic resonance imaging(MRI) in the diagnosis of avascular necrosis(AVN) of the femoral head, we compared appearances on MRI of 85 proven AVN lesions with those on radiographs(n=79) and radionuclide scans(n=75). Clinical symptoms(n=85) were also correlated. All MR studies included coronal and axial T1WI and coronal T2WI. All lesions involved the anterosuperterior aspect of the femoral head and were surrounded by a low signal intensity rim on both T1 and T2WI. The signal intensity of the lesions was variable depending on the disease course, and the lesions were divided into four classes according to the classification suggested by Mitchell. Radiographs were normal in 16%(13/79) of the lesions which were in MR class A(10), B(1), C(2). The radionuclide scans showed normal in 16%(12/75) of the lesions which were in MR class A(8). B(1), C(2), D(1). On the other hand, 93% of the lesions with MR class A(27/29) showed stage 1 and 2 lesions on radiographs. Clinical symptoms were absent in 25%(21/85) of the lesions, and among these,81%(17/21) were MR class A. Conclusively, MR is superior to the radiography and radionuclide scan in the early detection of AVN, and can also show the exact location, extent and signal characteristic of the lesion. Therefore, Mr is essential in diagnosis and management of AVN

  6. Evaluation of different physical parameters that affect the clinical image quality for gamma camera by using different radionuclides

    International Nuclear Information System (INIS)

    Salah, F.A.; Ziada, G.; Hejazy, M.A.; Khalil, W.A.

    2008-01-01

    Some scintillation camera manufactures adhere to standard code of performance specification established by National Electric Manufactures Association (NEMA). Items such as differential and integral uniformity, spatial resolution energy resolution, etc. are all calculated with reproducible methodology that allows the user reliable technique for creation of these standards to avoid any lack of clinical service that may violate the ethics of patient care. Because 99m Tc is the most frequently used radionuclide in nuclear medicine, many clinics perform the daily uniformity and weekly resolution checks using this radionuclide. But when other commonly used radionuclide such as Tl-201,Ga-67 and I-131 are used, no standardized quality control is performed. So in these study we perform to evaluate the response of ADAC(digital) gamma camera and SELO(analogue) gamma camera to four radionuclide (Tl-201,Ga-67, I-131, and 99m Tc) flood image acquired using different non-uniformity correction tables. In the planer study uniformity and resolution images were obtained using ADAC and SELO cameras, linearity was obtained only by ADAC camera, while in the SPECT study uniformity and contrast images were obtained using ADAC camera only. The response for using different non-uniformity correction tables acquired using different isotopes was different from gamma camera model to another. We can conclude that the most of the gamma camera quality control parameters (uniformity, resolution and contrast) are influenced by variation in the correction tables, while other parameters not affected by this variation like linearity. (author)

  7. Scatter and crosstalk corrections for 99mTc/123I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators

    International Nuclear Information System (INIS)

    Fan, Peng; Hutton, Brian F.; Holstensson, Maria; Ljungberg, Michael; Hendrik Pretorius, P.; Prasad, Rameshwar; Liu, Chi; Ma, Tianyu; Liu, Yaqiang; Wang, Shi; Thorn, Stephanie L.; Stacy, Mitchel R.; Sinusas, Albert J.

    2015-01-01

    Purpose: The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for 99m Tc/ 123 I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). Methods: A tailing model was developed to account for the low energy tail effects of the CZT detector. The parameters of the model were obtained using 99m Tc and 123 I point source measurements. A scatter model was defined to characterize the relationship between down-scatter and self-scatter projections. The parameters for this model were obtained from Monte Carlo simulation using SIMIND. The tailing and scatter models were further incorporated into a projection count model, and the primary and self-scatter projections of each radionuclide were determined with a maximum likelihood expectation maximization (MLEM) iterative estimation approach. The extracted scatter and crosstalk projections were then incorporated into MLEM image reconstruction as an additive term in forward projection to obtain scatter- and crosstalk-corrected images. The proposed method was validated using Monte Carlo simulation, line source experiment, anthropomorphic torso phantom studies, and patient studies. The performance of the proposed method was also compared to that obtained with the conventional TEW method. Results: Monte Carlo simulations and line source experiment demonstrated that the TEW method overestimated scatter while their proposed method provided more accurate scatter estimation by considering the low energy tail effect. In the phantom study, improved defect contrasts were observed with both

  8. Myocardial imaging in coronary heart disease with radionuclides, with emphasis on thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F J.Th.; Sokole, E B; Samson, G; van der Schoot, J B; Wellens, H J.J. [Amsterdam Univ. (Netherlands). Academisch Ziekenhuis

    1976-09-01

    During the past few years there has been an increasing interest in cardiology for myocardial imaging with radionuclides. At present the experience with both negative (thallium-201) and positive (sup(99m)Tc-pyrophosphate) imaging of myocardial infarction is increasing rapidly. Since 1974, over 1100 patient studies with thallium-201 were performed. In this article a survey is presented of experience with thallium-201 in patients with acute and chronic coronary artery disease. In patients with acute myocardial infarction data from studies with sup(99m)Tc-pyrophosphate will be discussed as well.

  9. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wollongong Univ.; Tomiyoshi, K.; Sekine, T.

    1997-01-01

    The present status and future directions of research and development on radionuclide generator technology are reported. The recent interest to develop double-neutron capture reactions for production of in vivo generators; neutron rich nuclides for radio-immunotherapeutic pharmaceuticals: and advances with ultra-short lived generators is highlighted. Emphasis is focused on: production of the parent radionuclide; the selection and the evaluation of support materials and eluents with respect to the resultant radiochemical yield of the daughter, and the breakthrough of the radionuclide parent: and, the uses of radionuclide generators in radiopharmaceutical chemistry, biomedical and industrial applications. The 62 Zn → 62 Cu, 66 Ni → 66 Cu, 103m Rh → 103 Rh, 188 W → 188 Re and the 225 Ac → 221 Fr → 213 Bi generators are predicted to be emphasized for future development. Coverage of the 99 Mo → 99m Tc generator was excluded, as it the subject of another review. The literature search ended June, 1996. (orig.)

  10. Radionuclide cisternographic findings in patients with spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Jung, Dong Jin; Kim, Jae Seung; Ryu, Jin Sook; Shin, Jung Woo; Im, Joo Hyuk; Lee, Myoung Chong; Jung, Sung Joo; Moon, Dae Hyuk; Lee, Hee Kyung

    1998-01-01

    Radionuclide cisternography may be helpful in understanding pathophysiology of postural headache and low CSF pressure in patients with spontaneous intracranial hypotension. The purpose of this study was to characterize radionuclide cisternogrpahic findings of spontaneous intracranial hypotension. The study population consists of 15 patients with spontaneous intracranial hypotension. Diagnosis was based on their clinical symptoms and results of lumbar puncture. All patients underwent radionuclide cisternography following injection of 111 to 222 MBq of Tc-99m DTPA into the lumbar subarachnoid space. Sequential images were obtained between 1/2 hour and 24 hour after the injection of Tc-99m DTPA. Radioactivity of the bladder, soft tissue uptake, migration of radionuclide in the subarachnoid space, and extradural leakage of radionuclide were evaluated according to the scan time. Radionuclide cisternogram showed delayed migration of radionuclide into the cerebral convexity (14/15), increased soft tissue uptake (11/15), and early visualization of bladder activity at 30 min (6/10) and 2 hr (13/13). Cisternography also demonstrated leakage site of CSF in 4 cases and 2 of these were depicted at 30min. Epidural blood patch was done in 11 patients and headache was improved in all cases. The characteristics findings of spontaneous intracranial hypotension were delayed migration of radionuclide and early visualization of the soft tissue and bladder activity. These scintigraphic findings suggest that CSF leakage rather than increased CSF absorption or decreased production may be the main pathophysiology of spontaneous intracranial hypotension. Early and multiple imaging including the bladder and soft tissue is required to observe the entire dynamics of radionuclide migration

  11. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  12. Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay

    International Nuclear Information System (INIS)

    Takashima, T.; Matsui, O.; Suzuki, M.; Ida, M.

    1982-01-01

    Twenty-nine small (less than 5 cm) hepatocellular carcinomas in 18 patients were examined by radionuclide imaging (RN), ultrasound (US), computed tomography (CT), hepatic angiography, and serum alpha 1-fetoprotein (AFP) assay. Sensitivity was 39% with RN, 50% with US, 56% with CT, and 94% with angiography, including infusion hepatic angiography (IHA). Lesions larger than 3 cm could be detected by all of these methods; those between 2 and 3 cm were generally shown by US and CT but not RN. IHA was essential for diagnosis of lesions less than 2 cm, which were otherwise difficult or impossible to detect except with angiography. As a screening method, AFP was best, followed by US and CT. The authors recommend using AFP and US to minimize expense and radiation exposure. In questionable cases, IHA should be performed

  13. A motion correction algorithm for an image realignment programme useful for sequential radionuclide renography

    International Nuclear Information System (INIS)

    De Agostini, A.; Moretti, R.; Belletti, S.; Maira, G.; Magri, G.C.; Bestagno, M.

    1992-01-01

    The correction of organ movements in sequential radionuclide renography was done using an iterative algorithm that, by means of a set of rectangular regions of interest (ROIs), did not require any anatomical marker or manual elaboration of frames. The realignment programme here proposed is quite independent of the spatial and temporal distribution of activity and analyses the rotational movement in a simplified but reliable way. The position of the object inside a frame is evaluated by choosing the best ROI in a set of ROIs shifted 1 pixel around the central one. Statistical tests have to be fulfilled by the algorithm in order to activate the realignment procedure. Validation of the algorithm was done for different acquisition set-ups and organ movements. Results, summarized in Table 1, show that in about 90% of the stimulated experiments the algorithm is able to correct the movements of the object with a maximum error less of equal to 1 pixel limit. The usefulness of the realignment programme was demonstrated with sequential radionuclide renography as a typical clinical application. The algorithm-corrected curves of a 1-year-old patient were completely different from those obtained without a motion correction procedure. The algorithm may be applicable also to other types of scintigraphic examinations, besides functional imaging in which the realignment of frames of the dynamic sequence was an intrinsic demand. (orig.)

  14. Report of the 2. research coordination meeting on development of generator technologies for therapeutic radionuclides

    International Nuclear Information System (INIS)

    2006-01-01

    The objectives of this CRP are to evaluate various generator and concentration technologies for 188 W- 188 Re, 99 Mo- 99 mTc and 90 Sr- 90 Y generators, to optimize generator fabrication and use, to standardize quality control techniques for the eluted radionuclides and to provide standardized procedures to participating laboratories. The following issues will be addressed during the CRP. - Development of reproducible methodologies for the preparation of 188 W- 188 Re, 99 Mo- 99 mTc and 90 Sr- 90 Y generators. - Development and evaluation of chromatography adsorbents (Zr/Ti composites) having higher binding capacities and demonstration of their utility in the preparation of column generators for 188 Re and 99 mTc. - Comparison and optimization of technologies for post elution concentration of 188 Re and 99 mTc in order to improve the radioactive concentration. - Development of quality control techniques and specifications for generator eluted therapeutic radionuclides

  15. Multiwire proportional gamma camera for imaging /sup 99/Tcsup(m) radionuclide distributions

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, J E; Connolly, J F [Science Research Council, Chilton (UK). Rutherford Lab.

    1978-05-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of /sup 99/Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m/sup 2/, a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77.

  16. A multiwire proportional gamma camera for imaging 99Tcsup(m) radionuclide distributions

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.

    1978-01-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of 99 Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m 2 , a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77. (author)

  17. Status of thermal imaging technology as applied to conservation-update 1

    Energy Technology Data Exchange (ETDEWEB)

    Snow, F.J.; Wood, J.T.; Barthle, R.C.

    1980-07-01

    This document updates the 1978 report on the status of thermal imaging technology as applied to energy conservation in buildings. Thermal imaging technology is discussed in terms of airborne surveys, ground survey programs, and application needs such as standards development and lower cost equipment. Information on the various thermal imaging devices was obtained from manufacturer's standard product literature. Listings are provided of infrared projects of the DOE building diagnostics program, of aerial thermographic firms, and of aerial survey programs. (LCL)

  18. Radionuclide concentrations in white sturgeon from the Columbia River. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Dauble, D.D.; Price, K.R.; Poston, T.M.

    1993-11-01

    The objectives of this study were to (1) review and summarize historical data on radionuclide concentrations in white sturgeon from the Columbia River, (2) determine present-day radionuclide tissue burdens from different locations in the Columbia River, and (3) compare historical data with current data. We first reviewed and summarized the historical literature on radionuclide concentrations in white sturgeon from the Hanford Reach. Field studies were then conducted to evaluate the relationship among sample locations, age/length of white sturgeon, and present radionuclide tissue burdens. Results and comparisons are discussed in the remainder of this report.

  19. The study of parotid function with radionuclide imaging after radiation therapy in nasopharyngeal cancer

    International Nuclear Information System (INIS)

    Li Huanbin; Zhang Qi; Wang Ling; Wu Shixiu; Xie Congying

    2006-01-01

    Objective: To study the uptake and excretion function of parotid by radionuclide imaging after simultaneous modulated accelerated radiation therapy (SMART) in nasopharyngeal cancer. Methods: Forty-eight nasopharyngeal cancer cases, 38 of them were treated by SMART with 2.5 Gy/fraction at tumor and enlarged lymph node to a total dose of 70 Gy, and 2.0 Gy/fraction at subclinical foci and prophy laxtic area volume to a total dose of 56 Gy in 38 d. The other 10 cases were treated by traditional radiation therapy (RT). After treatment, all patients performed parotid imaging and both uptake index (UI) and excretion index (EI) after acid stimulation were calculated. Clinical manifestation such as grade of mouth dryness was also analyzed. Results: Average UI and EI in SMART group decreased 21.9% and 37.3% respectively, with 12 cases moderate and severe mouth dryness, whereas in traditional RT group, mean UI and El decreased 56.1% and 96.1% respectively, with 9 cases moderate and severe mouth dryness. There was significant difference between them (P<0.05). Conclusion: Parotid imaging is sensitive for monitoring parotid function, and it is also reliable to evaluate the safety of SMART to parotid.. (authors)

  20. Experimental fracture healing: evaluation using radionuclide bone imaging: concise communication

    International Nuclear Information System (INIS)

    Gumerman, L.W.; Fogel, S.R.; Goodman, M.A.; Hanley, E.N. Jr.; Kappakas, G.S.; Rutkowski, R.; Levine, G.

    1978-01-01

    Radionuclide bone imaging was performed in a rabbit model to observe the course of fracture healing and to establish criteria for distinguishing nonunion and delayed healing from normal healing. Sequential gamma-camera images (with pinhole collimator) were collected and subjected to computer analysis. Five groups were established: (a) control--immobilization; (b) control--immobilization plus periosteal stripping; (c) simple fracture--osteotomy; (d) delayed union--osteotomy plus periosteal stripping; and (e) nonunion--osteotomy, periosteal stripping and polymethyl methacrylate interposed between fracture fragments. Histographic representation of absolute count rates along rabbit tibias followed a predictable pattern in the simple-fracture and delayed-union groups. They differed only in the time of appearance of phases. The non-union group demonstrated no recognizable sequential pattern. In this experimental model, serial bone scanning the quantitative data analysis has shown potential for indicating the course of healing in fractures and for serving as a guide to treatment

  1. The role of radionuclide studies in emergency cases

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hayashida, Kohei; Uehara, Toshiisa

    1982-01-01

    Radionuclide studies have been performed popularly because of its noninvasive and simple method recently. In this study, we applied this technique for the evaluation of emergency cases in cardiovascular diseases. There were 93 cases (1.5%) out of 6163 cases, done during 1981. The subjects were 34 cases of cardiac studies (9 cases of sup(99m)Tc-PYP myocardial imaging, 12 cases of thallium myocardial imaging, 13 cases of cardioangiography), 23 cases of peripheral diseases (12 cases of peripheral angiography, 11 cases of venography), 16 cases of pulmonary imaging, 10 cases of renal studies (6 cases of renal angiography, 9 cases of renal imaging) and 5 cases of brain angiography. These studies were proven to be useful clinically for the evaluation of emergency cases and follow-up studies. In the near future, ''emergency radionuclide studies'' would be benefit for the high-risk patients noninvasively. (author)

  2. Radionuclide imaging and diagnosis of benign tumours of the liver

    International Nuclear Information System (INIS)

    Zerbib, E.

    1996-01-01

    Radionuclide scanning takes advantages of the function of the liver. Hepatic scintigraphy can be suggested in the evaluation of solid liver masses greater than 1.5 cm and whose diagnosis has not been established by another imaging technique. 99m Tc-labeled-red-blood-cell (RBC) scintigraphy is very specific of cavernous hepatic hemangioma (100 %). Sensibility increases with tumoral size: 85 % from 1.5 to 3 cm and near 100 % beyond 3 cm. RBC scintigraphy should be performed when MRI does not assert diagnosis or cannot be performed. With 99m Tc-nanocolloids, focal nodular hyperplasia (FNH) can show intense concentration which is quite specific but appears in only 10 to 15 % of cases. A normal uptake is seen in 50 to 60 % of cases but only suggests FNH since almost 10 % of the adenomas get the same appearance. A negative defect, seen in 30 to 40 % of cases, does not allow any conclusion. Using hepatobiliary radiopharmaceuticals (IDA) FNH appears with an increased uptake during the perfusion phase, a normal uptake during the first 10 minutes and again an increased uptake during late images (hot spot). Hepatic adenoma can appear as a negative defect (over 90 % of cases) or with normal uptake (less than 10 % of cases). Increased uptake is never seen. Its aspect using hepatobiliary radio-hepatobiliary radio-pharmaceuticals is not well established but it appears as a negative defect on the perfusion phase which should discriminate it from FHN. (author)

  3. Radionuclide Therapy. Chapter 19

    Energy Technology Data Exchange (ETDEWEB)

    Flux, G.; Du, Yong [Royal Marsden Hospital and Institute of Cancer Research, Surrey (United Kingdom)

    2014-12-15

    Cancer has been treated with radiopharmaceuticals since the 1940s. The radionuclides originally used, including 131I and 32P, are still in use. The role of the physicist in radionuclide therapy encompasses radiation protection, imaging and dosimetry. Radiation protection is of particular importance given the high activities of the unsealed sources that are often administered, and must take into account medical staff, comforters and carers, and, as patients are discharged while still retaining activity, members of the public. Regulations concerning acceptable levels of exposure vary from country to country. If the administered radiopharmaceutical is a γ emitter, then imaging can be performed which may be either qualitative or quantitative. While a regular system of quality control must be in place to prevent misinterpretation of image data, qualitative imaging does not usually rely on the image corrections necessary to determine the absolute levels of activity that are localized in the patient. Accurate quantitative imaging is dependent on these corrections and can permit the distribution of absorbed doses delivered to the patient to be determined with sufficient accuracy to be clinically beneficial.

  4. Quantum imaging technologies

    International Nuclear Information System (INIS)

    Malik, M.; Boyd, R.W.

    2014-01-01

    Over the past three decades, quantum mechanics has allowed the development of technologies that provide unconditionally secure communication. In parallel, the quantum nature of the transverse electromagnetic field has spawned the field of quantum imaging that encompasses technologies such as quantum lithography, quantum ghost imaging, and high-dimensional quantum key distribution (QKD). The emergence of such quantum technologies also highlights the need for the development of accurate and efficient methods of measuring and characterizing the elusive quantum state itself. In this paper, we describe new technologies that use the quantum properties of light for security. The first of these is a technique that extends the principles behind QKD to the field of imaging and optical ranging. By applying the polarization-based BB84 protocol to individual photons in an active imaging system, we obtained images that are secure against any interceptresend jamming attacks. The second technology presented in this article is based on an extension of quantum ghost imaging, a technique that uses position-momentum entangled photons to create an image of an object without directly obtaining any spatial information from it. We used a holographic filtering technique to build a quantum ghost image identification system that uses a few pairs of photons to identify an object from a set of known objects. The third technology addressed in this document is a high-dimensional QKD system that uses orbital-angular-momentum (OAM) modes of light for encoding. Moving to a high-dimensional state space in QKD allows one to impress more information on each photon, as well as introduce higher levels of security. We discuss the development of two OAM-QKD protocols based on the BB84 and Ekert protocols of QKD. The fourth and final technology presented in this article is a relatively new technique called direct measurement that uses sequential weak and strong measurements to characterize a quantum state

  5. Role of radionuclide imaging in the diagnosis of acute osteomyelitis

    International Nuclear Information System (INIS)

    Demopulos, G.A.; Bleck, E.E.; McDougall, I.R.

    1988-01-01

    Over the last decade, the role of nuclear medicine studies in the diagnosis of acute osteomyelitis has been discussed in depth in the literature. Yet, the respective roles played in this setting by each of the commonly used radionuclide studies often are confusing. In an attempt to develop a cogent diagnostic strategy, we reviewed the literature published within the last 12 years pertaining to the use of radiophosphate bone scintigraphy as well as gallium and indium WBC imaging in the diagnosis of this condition. Based on our findings, we propose an alternative approach to the evaluation of a patient with suspected acute osteomyelitis. 63 references

  6. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1992--July 15, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1995-07-17

    This research continues the long term goals of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. This program fits into the nuclear medicine component of DOE`s mission, which is aimed at enhancing the beneficial applications of radiation, radionuclides, and stable isotopes in the diagnosis, study and treatment of human diseases. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology/Immunology; and Imaging Physics. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Section under the DOE grant during the 1992--1995 will be employed in the Pharmacology/Immunology component in the period 1996--1999. Imaging Physics resolves relevant imaging related physics issues that arise during the experimentation that results. In addition to the basic research mission, this project also provides a basis for training of research scientists in radiochemistry, immunology, bioengineering and imaging physics.

  7. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1992--July 15, 1995

    International Nuclear Information System (INIS)

    Larson, S.M.; Finn, R.D.

    1995-01-01

    This research continues the long term goals of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. This program fits into the nuclear medicine component of DOE's mission, which is aimed at enhancing the beneficial applications of radiation, radionuclides, and stable isotopes in the diagnosis, study and treatment of human diseases. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology/Immunology; and Imaging Physics. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Section under the DOE grant during the 1992--1995 will be employed in the Pharmacology/Immunology component in the period 1996--1999. Imaging Physics resolves relevant imaging related physics issues that arise during the experimentation that results. In addition to the basic research mission, this project also provides a basis for training of research scientists in radiochemistry, immunology, bioengineering and imaging physics

  8. Scatter and crosstalk corrections for {sup 99m}Tc/{sup 123}I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Peng [Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520 and Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Hutton, Brian F. [Institute of Nuclear Medicine, University College London, London WC1E 6BT, United Kingdom and Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Holstensson, Maria [Department of Nuclear Medicine, Karolinska University Hospital, Stockholm 14186 (Sweden); Ljungberg, Michael [Department of Medical Radiation Physics, Lund University, Lund 222 41 (Sweden); Hendrik Pretorius, P. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Prasad, Rameshwar; Liu, Chi, E-mail: chi.liu@yale.edu [Department of Diagnostic Radiology, Yale University, New Haven, Connecticut 06520 (United States); Ma, Tianyu; Liu, Yaqiang; Wang, Shi [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Thorn, Stephanie L.; Stacy, Mitchel R.; Sinusas, Albert J. [Department of Internal Medicine, Yale Translational Research Imaging Center, Yale University, New Haven, Connecticut 06520 (United States)

    2015-12-15

    Purpose: The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for {sup 99m}Tc/{sup 123}I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). Methods: A tailing model was developed to account for the low energy tail effects of the CZT detector. The parameters of the model were obtained using {sup 99m}Tc and {sup 123}I point source measurements. A scatter model was defined to characterize the relationship between down-scatter and self-scatter projections. The parameters for this model were obtained from Monte Carlo simulation using SIMIND. The tailing and scatter models were further incorporated into a projection count model, and the primary and self-scatter projections of each radionuclide were determined with a maximum likelihood expectation maximization (MLEM) iterative estimation approach. The extracted scatter and crosstalk projections were then incorporated into MLEM image reconstruction as an additive term in forward projection to obtain scatter- and crosstalk-corrected images. The proposed method was validated using Monte Carlo simulation, line source experiment, anthropomorphic torso phantom studies, and patient studies. The performance of the proposed method was also compared to that obtained with the conventional TEW method. Results: Monte Carlo simulations and line source experiment demonstrated that the TEW method overestimated scatter while their proposed method provided more accurate scatter estimation by considering the low energy tail effect. In the phantom study, improved defect contrasts were

  9. Radioisotopes for imaging and radionuclide targeted therapy in nuclear medicine

    Czech Academy of Sciences Publication Activity Database

    Forsterová, Michaela; Zimová, Jana; Beran, Miloš

    -, - (2007), s. 76-77 ISSN N R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : metal radionuclides * bifunctional chelators Subject RIV: FR - Pharmacology ; Medidal Chemistry

  10. Radionuclide examinations

    International Nuclear Information System (INIS)

    Lentle, B.C.

    1989-01-01

    This paper reports on radionuclide examinations of the pancreas. The pancreas, situated retroperitonally high in the epigastrium, was a particularly difficult organ to image noninvasively before ultrasonography and computed tomography (CT) became available. Indeed the organ still remains difficult to examine in some patients, a fact reflected in the variety of methods available to evaluate pancreatic morphology. It is something of a paradox that the pancreas is metabolically active and physiologically important but that its examination by radionuclide methods has virtually ceased to have any role in day-to-day clinical practice. To some extent this is caused by the tendency of the pancreas's commonest gross diseases emdash carcinoma and pancreatitis, for example emdash to result in nonfunction of the entire organ. Disorders of pancreatic endocrine function have generally not required imaging methods for diagnosis, although an understanding of diabetes mellitus and its nosology has been advanced by radioimmunoassay of plasma insulin concentrations

  11. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  12. Frontiers in medical imaging technology

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1992-01-01

    At present many medical images are used for diagnostics and treatment. After the advent of X-ray computer tomography (XCT), the violent development of medical images has continued. Medical imaging technology can be defined as the field of technology that deals with the production, processing, display, transmission, evaluation and so on of medical images, and it can be said that the present development of medical imaging diagnostics has been led by medical imaging technology. In this report, the most advanced technology of medical imaging is explained. The principle of XCT is shown. The feature of XCT is that it can image the delicate difference in the X-ray absorption factor of the cross section being measured. The technical development has been advanced to reduce the time for imaging and to heighten the resolution. The technology which brings about a large impact to future imaging diagnostics is computed radiography. Magnetic resonance imaging is the method of imaging the distribution of protons in human bodies. Positron CT is the method of measurement by injecting a positron-emitting RI. These methods are explained. (K.I.)

  13. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    International Nuclear Information System (INIS)

    Kuhl, D.E.

    1981-01-01

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma

  14. Production of high-specific activity radionuclides using SM high-flux reactor

    International Nuclear Information System (INIS)

    Karelin, Ye.A.; Toporov, Yu.G.; Filimonov, V.T.; Vakhetov, F.Z.; Tarasov, V.A.; Kuznetsov, R.A.; Lebedev, V.M.; Andreev, O.I.; Melnik, M.I.; Gavrilov, V.D.

    1997-01-01

    The development of High Specific Activity (HSA) radionuclides production technologies is one of the directions of RIAR activity, and the high flux research reactor SM, having neutron flux density up to 2.10 15 cm -2 s 1 in a wide range of neutron spectra hardness, plays the principal role in this development. The use of a high-flux reactor for radionuclide production provides the following advantages: production of radionuclides with extremely high specific activity, decreasing of impurities content in irradiated targets (both radioactive and non-radioactive), cost-effective use of expensive isotopically enriched target materials. The production technologies of P-33, Gd-153, W-188, Ni-63, Fe-55,59, Sn-113,117m,119m, Sr- 89, applied in industry, nuclear medicine, research, etc, were developed by RIAR during the last 5-10 years. The research work included the development of calculation procedures for radionuclide reactor accumulation forecast, experimental determination of neutron cross-sections, the development of irradiated materials reprocessing procedures, isolation and purification of radionuclides. The principal results are reviewed in the paper. (authors)

  15. Radionuclide table. Pt. 1

    International Nuclear Information System (INIS)

    Legrand, Jean; Perolat, J.-P.; Lagoutine, Frederic; Le Gallic, Yves.

    The evaluation of the following 29 radionuclides is presented: 22 Na, 24 Na, sup(24m)Na, 51 Cr, 54 Mn, 57 Co, 58 Co, sup(58m)Co, 60 Co, sup(60m)Co, 75 Se, 103 Ru, sup(103m)Rh, sup(110m)Ag- 110 Ag, 109 Cd, 125 Sb, sup(125mTe), 125 I, 133 Xe, sup(133m)Xe, 131 Cs, 134 Cs, sup(134m)Cs, 139 Ce, 144 Ce- 144 Pr, 144 Pr, 169 Er, 186 Re, 203 Hg. The introduction contains a brief description of radioactive processes and the evaluation rules followed. The best values and associated uncertainties are given for each radionuclide for the major parameters of the decay scheme and the radiation intensities emitted, together with a decay table. Gamma, X-rays and sometimes conversion electron spectra are also provided [fr

  16. Harvard--MIT research program in short-lived radiopharmaceuticals. Progress report, September 1, 1977--April 30, 1978. [/sup 99m/Tc, positron-emitting radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Adelstein, S.J.; Brownell, G.L.

    1978-05-01

    Progress is reported on the following studies: chemistry studies designed to achieve a more complete understanding of the fundamental chemistry of technetium in order to facilitate the design of future radiopharmaceuticals incorporating the radionuclide /sup 99m/Tc; the development of new radiopharmaceuticals intended to improve image quality and lower radiation doses by the use of short-lived radionuclides and disease-specific agents; the development of short-lived positron-emitting radionuclides which offer advantages in transverse section imaging of regional physiological processes; and studies of the toxic effects of particulate radiation.

  17. 3D-LSI technology for image sensor

    International Nuclear Information System (INIS)

    Motoyoshi, Makoto; Koyanagi, Mitsumasa

    2009-01-01

    Recently, the development of three-dimensional large-scale integration (3D-LSI) technologies has accelerated and has advanced from the research level or the limited production level to the investigation level, which might lead to mass production. By separating 3D-LSI technology into elementary technologies such as (1) through silicon via (TSV) formation, (2) bump formation, (3) wafer thinning, (4) chip/wafer alignment, and (5) chip/wafer stacking and reconstructing the entire process and structure, many methods to realize 3D-LSI devices can be developed. However, by considering a specific application, the supply chain of base wafers, and the purpose of 3D integration, a few suitable combinations can be identified. In this paper, we focus on the application of 3D-LSI technologies to image sensors. We describe the process and structure of the chip size package (CSP), developed on the basis of current and advanced 3D-LSI technologies, to be used in CMOS image sensors. Using the current LSI technologies, CSPs for 1.3 M, 2 M, and 5 M pixel CMOS image sensors were successfully fabricated without any performance degradation. 3D-LSI devices can be potentially employed in high-performance focal-plane-array image sensors. We propose a high-speed image sensor with an optical fill factor of 100% to be developed using next-generation 3D-LSI technology and fabricated using micro(μ)-bumps and micro(μ)-TSVs.

  18. Radionuclide toxicity

    International Nuclear Information System (INIS)

    Galle, P.

    1982-01-01

    The aim of this symposium was to review the radionuclide toxicity problems. Five topics were discussed: (1) natural and artificial radionuclides (origin, presence or emission in the environment, human irradiation); (2) environmental behaviour of radionuclides and transfer to man; (3) metabolism and toxicity of radionuclides (radioiodine, strontium, rare gas released from nuclear power plants, ruthenium-activation metals, rare earths, tritium, carbon 14, plutonium, americium, curium and einsteinium, neptunium, californium, uranium) cancerogenous effects of radon 222 and of its danghter products; (4) comparison of the hazards of various types of energy; (5) human epidemiology of radionuclide toxicity (bone cancer induction by radium, lung cancer induction by radon daughter products, liver cancer and leukaemia following the use of Thorotrast, thyroid cancer; other site of cancer induction by radionuclides) [fr

  19. Local experience on radionuclide myocardial imaging in the Philippines at the Philippine Heart Center for Asia

    International Nuclear Information System (INIS)

    Villacorta, E.V.

    1977-01-01

    The Nuclear Medicine Department of the Philippine Heart Center has introduced the detection of coronary heart disease through myocardiac perfusion imaging. The cardiovascular procedures are availed of free-of-charge to registered PHCA patients excepting for the costly TI-201 imaging. In summary, coronary perfusion in imaging should be an integral part of coronary arteriography. Barring the expensive cost of TI-120, myocardial perfusion imaging is ideal for detection of coronary heart disease. Experience shows better sensitivity of TI-201 than exercise ECG for detection of ischemia. Another non-invasive procedure for the detection of acute infarction is the radionuclide imaging using a bone radiopharmaceutical Tc99m prophosphate. In conclusion, acute infarct imaging is a valuable adjunct to ECG and enzyme studies. (RTD)

  20. EDITORIAL: Molecular Imaging Technology

    Science.gov (United States)

    Asai, Keisuke; Okamoto, Koji

    2006-06-01

    'Molecular Imaging Technology' focuses on image-based techniques using nanoscale molecules as sensor probes to measure spatial variations of various species (molecular oxygen, singlet oxygen, carbon dioxide, nitric monoxide, etc) and physical properties (pressure, temperature, skin friction, velocity, mechanical stress, etc). This special feature, starting on page 1237, contains selected papers from The International Workshop on Molecular Imaging for Interdisciplinary Research, sponsored by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) in Japan, which was held at the Sendai Mediatheque, Sendai, Japan, on 8 9 November 2004. The workshop was held as a sequel to the MOSAIC International Workshop that was held in Tokyo in 2003, to summarize the outcome of the 'MOSAIC Project', a five-year interdisciplinary project supported by Techno-Infrastructure Program, the Special Coordination Fund for Promotion of Science Technology to develop molecular sensor technology for aero-thermodynamic research. The workshop focused on molecular imaging technology and its applications to interdisciplinary research areas. More than 110 people attended this workshop from various research fields such as aerospace engineering, automotive engineering, radiotechnology, fluid dynamics, bio-science/engineering and medical engineering. The purpose of this workshop is to stimulate intermixing of these interdisciplinary fields for further development of molecular sensor and imaging technology. It is our pleasure to publish the seven papers selected from our workshop as a special feature in Measurement and Science Technology. We will be happy if this issue inspires people to explore the future direction of molecular imaging technology for interdisciplinary research.

  1. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  2. Radionuclide dynamic renal imaging for renal function study in patients with NIDDM

    International Nuclear Information System (INIS)

    Yang Ruiping; Qu Wanying; Gao Wenping

    1996-01-01

    Radionuclide dynamic renal imaging was performed to gain evidence for further treatment and evaluation of prognosis in patients with non-insulin-dependent diabetes mellitus (NIDDM). 99m Tc-DTPA dynamic renal imaging was performed in 137 NIDDM patients and 44 normal controls (NC). Glomerular filtration rate (GFR) and renogram were acquired simultaneously. Renal tubular secretion function was measured with 99m Tc-EC in 126 of the 137 diabetics and 17 NC. GFR decreased in all patients with different duration of NIDDM and the difference was remarkably significance in comparison with NC (t = 7.17∼13.73, P 99m Tc-EC. This study showed that the function of glomerular filtration and tubular secretion were both damaged in all diabetics. Their magnitude was aggravated with the prolongation of the course of disease

  3. Radiopharmaceuticals based on the scandium or rhodium radionuclides

    International Nuclear Information System (INIS)

    Majkowska, A.; Pruszynski, M.; Bilewicz, A.

    2006-01-01

    Radionuclides 103m Rh, 105 Rh emitting β-radiation or 47 Sc (Auger electrons emitter) are suitable for treatment small tumors spread over the human tissues. Presented communication describes preliminary results obtained in the Institute of Nuclear Chemistry and Technology, Warsaw (Poland) in the field of obtaining new complexes containing the aforementioned radionuclides. The radionuclides can be produced in the laboratory scale from simple and cheap generators. 103m Rh and 105 Rh cations were complexed with the thioetheric ligand (1,5,9,13-tetrathiacyclahexadecane-3,11-diole) and in the future, after funcionalization with certain biomolecules, are promising radiopharmaceuticals. 47 Sc cation was complexes by one from the following tri- or tetraaza macoryclic ligands: 1,4,7,10-triazacyclononane-1,4,7-triacetic acid (NOTA), 1,4,7,10-tetraazacyclododecane-1,7-diacetic acid (DO2A) or 1,4,7,10-triazacyclononane-1,4,7-triacetic acid (NOTA), 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA). Composition and the stability constants of the complexes were determined

  4. Application of radionuclide imaging in grading and therapeutic evaluation in patients with fallopian tube dysfunction

    International Nuclear Information System (INIS)

    Liu Zhixiang; Zhang Yanhua; Li Guangzhou; Zhang Peisen; Xie Hai; Sun Tao; Ren Chun'e; Zhang Shizhuang; Jiang Aifang

    2012-01-01

    Objective: To observe the conception status of patients with fallopian tube dysfunction after medical treatment and to guide treatment strategy for patients with different degrees of tubal injury by radionuclide imaging. Methods Six hundred and two patients with at least one side of patent fallopian tube underwent modified fallopian tube radionuclide imaging. The patients were graded as: mild, moderate or severe injury, non-functioning or tubal obstruction. The conception status was analyzed after medical treatment, including abdominal hot pack with Chinese medicine, oral intake of Guizhi tuckahoe capsules,and Kangfu anti-inflammatory anal suppository. The constituent ratios of conception in different groups were compared using χ 2 test and the curative and effective rates were calculated. Results: After 1-6 cycles of medical treatment,patients with fallopian tube dysfunction had a curative rate of 29.5% (46/156) and effective rate of 71.8% (112/156). There was a statistically significant difference among the different degrees of oviduct injury (χ 2 =166.4, P<0.05). After medical treatment,the natural pregnancy rate for patients with bilateral mild, moderate and severe injury was 52.6% (102/194), 42.6% (46/108) and 13.8% (16/116), respectively. The rate for patients with one side of normal tubal function was 78.3% (144/184), which was significantly higher than that of patients with bilateral mild, moderate and severe injury (χ 2 =37.86, 52.09 and 121.71, all P<0.05). The natural pregnancy rates of both mild and moderate injury groups were significantly different from the severe injury group (χ 2 =67.29, 42.82, both P<0.05), but there was no difference between the mild and moderate injury groups (χ 2 =3.29, P>0.05). In the severe injury group, 32.8% (38/116) patients were naturally infertile after the medical treatment, while 53.4% (62/116) patients underwent in vitro fertilization (IVF) and 51.6% (32/62) of them succeeded in pregnancy. Conclusions: The natural

  5. 40 CFR 141.66 - Maximum contaminant levels for radionuclides.

    Science.gov (United States)

    2010-07-01

    ... beta particle and photon radioactivity from man-made radionuclides in drinking water must not produce.../year). (2) Except for the radionuclides listed in table A, the concentration of man-made radionuclides... may make this technology too complex for small surface water systems. e Removal efficiencies can vary...

  6. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  7. Turbine imaging technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Moursund, R. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Carlson, T. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-12-01

    The goal of this project was to identify and evaluate imaging technologies for observing juvenile fish within a Kaplan turbine, and specifically that would enable scientists to determine mechanisms of fish injury within an operating turbine unit. This report documents the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. These observations were used to make modifications to dam structures and operations to improve conditions for fish passage while maintaining or improving hydropower production. The physical and hydraulic environment that fish experience as they pass through the hydroelectric plants were studied and the regions with the greatest potential for injury were defined. Biological response data were also studied to determine the probable types of injuries sustained in the turbine intake and what types of injuries are detectable with imaging technologies. The study grouped injury-causing mechanisms into two categories: fluid (pressure/cavitation, shear, turbulence) and mechanical (strike/collision, grinding/pinching, scraping). The physical constraints of the environment, together with the likely types of injuries to fish, provided the parameters needed for a rigorous imaging technology evaluation. Types of technology evaluated included both tracking and imaging systems using acoustic technologies (such as sonar and acoustic tags) and optic technologies (such as pulsed-laser videography, which is high-speed videography using a laser as the flash). Criteria for determining image data quality such as frame rate, target detectability, and resolution were used to quantify the minimum requirements of an imaging sensor.

  8. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  9. Prosthetic joint infections: radionuclide state-of-the-art imaging

    International Nuclear Information System (INIS)

    Gemmel, Filip; Wyngaert, Hans van den; Love, Charito; Welling, M.M.; Gemmel, Paul; Palestro, Christopher J.

    2012-01-01

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  10. Technologies for destruction of long-lived radionuclides in high-level nuclear waste: Overview and requirements

    International Nuclear Information System (INIS)

    Arthur, E.D.

    1993-01-01

    This paper, and this topical session on Nuclear Waste Minimization, Management and Remediation, focuses on two nuclear systems, and their associated technologies, that have the potential to address concerns surrounding long-lived radionuclides in high-level waste. Both systems offer technology applicable to HLW from present light-water reactors (LWR). Additionally these systems represent advanced nuclear power concepts that have important features associated with integrated management of wastes, long-term fuel supplies, and enhanced safety. The first system is the Integral Fast Reactor (IFR) concept. This system incorporates a metal-fueled fast reactor coupled with chemical separations based on pyroprocessing to produce power while simultaneously burning long-lived actinide waste. IFR applications include burning of actinides from current LWR spent fuel and energy production in a breeder environment. The second concept, Accelerator Transmutation of Waste (ATW), is based upon an accelerator-induced intense source of thermal neutrons and is aimed at destruction of long-lived actinides and fission products. This concept can be applied to long-lived radionuclides in spent fuel HLW as well as a future fission power source built around use of natural thorium or uranium as fuels coupled with concurrent waste destruction

  11. Medical Physics Staffing Needs in Diagnostic Imaging and Radionuclide Therapy: An Activity Based Approach [Endorsed by International Organization for Medical Physics

    International Nuclear Information System (INIS)

    2018-01-01

    Over the last decades, the rapid technological development of diagnostic and interventional radiology and nuclear medicine has made them major tools of modern medicine. However, at the same time the involved risks, the growing number of procedures and the increasing complexity of the procedures require competent professional staff to ensure safe and effective patient diagnosis, treatment and management. Medical physicists (or clinically qualified medical physicists) have been recognized as vital health professionals with important and clear responsibilities related to quality and safety of applications of ionizing radiation in medicine. This publication describes an algorithm developed to determine the recommended staffing levels for clinical medical physics services in medical imaging and radionuclide therapy, based on current best practice, as described in international guidelines.

  12. Choice of radionuclide for antibody labelling: new perspectives

    International Nuclear Information System (INIS)

    Hazra, D.K.; Dass, S.

    1983-01-01

    The expanding horizons of labelled antibody techniques in diagnostic imaging or assay, therapy and research and the availabilities of monoclonal antibodies is resulting in a demand for suitable radionuclides as antibody labels. An outline is given of the different criteria for choosing an appropriate radionuclide for labelling an antibody depending on its particular field of use. The requirements of procedures for firmly linking radionuclides to antibodies are also given. (U.K.)

  13. Kinetic regularities of change in the concentration of radionuclides in the Georgian tea content

    International Nuclear Information System (INIS)

    Mosulishvili, L.M.; Katamadze, N.M.; Shoniya, N.I.; Ginturi, Eh.N.

    1990-01-01

    The paper is concerned with the results of a study of behavior of artificial radionuclides in Georgian tea technological products after the accident at the Chernobyl Nuclear Station. A partial contribution of the activity of radionuclides 141 Ce, 140 La, 103 Ru, 106 Ru, 140 Ba, 137 Cs, 95 Nb, 95 Zr, 134 Cs and 90 Sr to the total activity to Georgian tea samples. Maximum tolerated concentrations of radionuclides were assessed provided average annual tea consumption per capita was 1 kg. The maximum of solubility in the water phase falls on Cs radionuclides. The regularities of migration of half-lived radionuclides 3 yrs. After the Chernobyl accident were established

  14. Radionuclide imaging of bone marrow in hematologic systemic disease

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, F.; Hahn, K.; Gamm, H.

    1987-02-01

    Radionuclide imaging studies of the bone marrow were carried out in 164 patients suffering from hematologic systemic disease. One third of 90 patients with Hodgkin lymphoma (HL) or Non Hodgkin lymphoma (NHL) displayed a pathological distribution pattern representing bone marrow expansion. In HL there were 17% accumulation defects caused by metastases in contrast to only 7% in NHL. Among 30 patients with chronic myelocytic leukemia bone marrow expansion was found in 60%, bone marrow displacement and aplasia 10%. Focal bone marrow defects were found in 3 patients. All patients with primary polycythemia rubra vera displayed a pathologic bone marrow distribution pattern as well as splenomegaly. All patients with acute myelocytic leukemia (AML) and one patient with an acute lymphatic leukemia (ALL) had a pathological distribution pattern with bone marrow expansion and displacement. Focal bone marrow defects were not seen. Multiple myeloma with bone marrow expansion was found in 6 of 12 patients and focal accumulation defects were found in 40%, the latter lesions being not visible or equivocal on skeletal imaging studies. Pathological changes in liver and spleen were found in a high percentage of the total collective. The results document the important clinical value of bone marrow scintigraphy among the hematologic diseases studied.

  15. The evaluation of gastroesophageal reflux in children with chronic respiratory diseases by radionuclide gastroesophageal imaging

    International Nuclear Information System (INIS)

    Zhao Ruifang; Zeng Jihua; Shi Yumin

    1999-01-01

    Objective: To evaluate the gastroesophageal reflux (GER) in children with chronic respiratory diseases (CRD) by radionuclide gastroesophageal imaging and to investigate the therapeutic effect of Cisapride. Methods: 45 patients were studied with 99 Tc m -DTPA gastroesophageal imaging, and compared the results with those obtained from 8 normal children. The repeated imagings were performed on some of the cases at the end of a three months' Cisapride therapy. Results: 25 (55%) among 45 patients were diagnosed as GER by imaging, while none of 8 normal children. 10 cases with GER received Cisapride therapy for 3 months. At the end of the treatment, the second imaging revealed that GER completely disappeared in 7 of them, and clinical follow-up showed marked improvement of CRD symptoms. Conclusions: The incidence of GER among with CRD children is rather great. Cisapride therapy not only remarkably relieve reflux, but also improve the symptoms of CRD

  16. radiochemical study on the medically and technology radionuclides of some lanthanides

    International Nuclear Information System (INIS)

    Aglan, H.A.E.

    2010-01-01

    In this work, trials for the production of the medically and technologically interesting 139 Ce and 142 Pr radionuclides through cyclotron irradiations using protons and alpha particles were studied. The radiochemical separation of no-carrier-added cerium from proton irradiated lanthanum was studied by solvent extraction using DEE, TBP and TPPO, the latter reagent being employed for the first time for separation of radio cerium from bulk of lanthanum. Distribution coefficients of cerium and lanthanum were investigated as a function of equilibrium time and HNO 3 concentration. A mixture of 0.05 M K 2 Cr 2 O 7 and 0.1 M H 2 SO 4 was used as an oxidizing agent to improve the separation efficiency of cerium. A comparative study of the three extractants released that DEE is the best for separation of cerium from bulk of lanthanum oxide. The target was prepared by pressing. The production of 139 Ce of high radionuclidic and chemical purity via irradiation of lanthanum oxide target at MGC-20 cyclotron with protons of energy 14.5 is described. The experimental yield was found to be 153 kBq/μAh .The adsorption behaviour of La/Ce system on Dowex 50W-X8 in different media, namely, nitric acid, acetate buffer and citrate buffer was studied as a function of the concentration of nitric acid and buffer ph. In addition, in cation-exchange column chromatography experiments, three different eluants, namely, citrate buffer of ph 5.5, 0.1 M EDTA and 0.2 M α-HIBA, were employed for separation of Ce (III) from La (III). The optimum conditions for improvement of radiochemical separation of no-carrier-added 139 Ce from proton irradiated lanthanum were applied using the most suitable chelating agent 0.2 M α-HIBA. The purification of 139 Ce from macro amount of La (III) was done using two columns in a sequence. The experimental yield was found to be 200 kBq/μAh.

  17. Craniofacial imaging informatics and technology development.

    Science.gov (United States)

    Vannier, M W

    2003-01-01

    'Craniofacial imaging informatics' refers to image and related scientific data from the dentomaxillofacial complex, and application of 'informatics techniques' (derived from disciplines such as applied mathematics, computer science and statistics) to understand and organize the information associated with the data. Major trends in information technology determine the progress made in craniofacial imaging and informatics. These trends include industry consolidation, disruptive technologies, Moore's law, electronic atlases and on-line databases. Each of these trends is explained and documented, relative to their influence on craniofacial imaging. Craniofacial imaging is influenced by major trends that affect all medical imaging and related informatics applications. The introduction of cone beam craniofacial computed tomography scanners is an example of a disruptive technology entering the field. An important opportunity lies in the integration of biologic knowledge repositories with craniofacial images. The progress of craniofacial imaging will continue subject to limitations imposed by the underlying technologies, especially imaging informatics. Disruptive technologies will play a major role in the evolution of this field.

  18. Recent progress in medical imaging technology

    International Nuclear Information System (INIS)

    Endo, Masahiro

    2004-01-01

    Medical imaging is name of methods for diagnosis and therapy, which make visible with physical media such as X-ray, structures and functions of man's inside those are usually invisible. These methods are classified by the physical media into ultrasound imaging, magnetic resonance imaging, nuclear medicine imaging and X-ray imaging etc. Having characteristics different from one another, these are used complementarily in medical fields though in some case being competitive. Medical imaging is supported by highly progressed technology, which is called medical imaging technology. This paper describes a survey of recent progress of medical imaging technology in magnetic resonance imaging, nuclear medicine imaging and X-ray imaging. (author)

  19. Natural radionuclide distribution in phosphate fertilizer and superphosphate production technology

    Energy Technology Data Exchange (ETDEWEB)

    Lisachenko, Eh P; Ponikarova, T M; Lisitsyna, Yu Z

    1987-01-01

    The obtained data on the natural radionuclide distribution by phosphate fertilizer and superphosphate production process stages testify to phosphate fertilizer enrichment 2-4 times in relation to initial ore, depending in the raw material used. In this case uranium and thorium series element concentration value (in equilibrium with their decomposition products), proposed as a regulating one in phosphorus-containing fertilizers, is not achieved. However, the fact of lurichment as it is and the enrichment factor, stated in the course of the work, should be taken into account for evaluation of phosphorite new deposit raw material with higher concentrations of natural radionuclides. Natural radionuclide separation in the enrichment process and superphosphate production is not revealed.

  20. Radionuclide transfer onto ground surface in surface water flow, 1

    International Nuclear Information System (INIS)

    Mukai, Masayuki; Takebe, Shinichi; Komiya, Tomokazu; Kamiyama, Hideo

    1991-07-01

    Radionuclides migration in ground surface water flow is considered to be one of the important path way in the scenario for environmental migration of radionuclides leaked from low level radioactive waste repository. Simulating the slightly sloped surface on which contaminated solution is flowing downward, testing for radionuclide migration on ground surface had been started. As it's first step, an experiment was carried out under the condition of restricted infiltration in order to elucidate the adsorption behavior of radionuclides onto the loamy soil surface in related with hydraulic conditions. Radionuclides concentration change in effluent solution with time and a concentration distribution of radionuclides adsorbed on the ground surface were obtained from several experimental conditions combining the rate and the duration time of the water flow. The radionuclides concentration in the effluent solution was nearly constant during each experimental period, and was reduced under the condition of lower flow rate. The surface distribution of radionuclides concentration showed two distinctive regions. The one was near the inlet vessel where the concentration was promptly reducing, and the other was following the former where the concentration was nearly constant. The characteristic surface distribution of radionuclides concentration can be explained by a two dimensional diffusion model with a first order adsorption reaction, based on the advection of flow rate distribution in perpendicular direction. (author)

  1. PROBLEMS OF PROTECTION OF URBAN AREAS FROM RADIONUCLIDES STRONTIUM-90 AND CAESIUM-137 AFTER TECHNOLOGICAL DISASTERS

    Directory of Open Access Journals (Sweden)

    Olga Cheremisina

    2017-05-01

    Full Text Available The methods of decontamination of radionuclides from soils are considered. The literature focuses on fixing radionuclides in soils and creating geochemical barriers that it is prevent the spread of pollution. The main disadvantage of these methods is exclude the possibility of building a territory. It is need to clean up the area to the sanitary and hygienic requirements for further use and then it is desirable to fix the residual activity. Carried out an analysis of forms of radionuclides fixation in soils and mechanics of this fixation, therewith revealed that Cs-137 fixed more strongly on mineral component of soil, than Sr-90, which is mainly in the acid-soluble and exchangeable form, and, as a consequence, passes into the liquid phase during soil deactivation more easily. Contaminated soil deactivation in the urbanized territory is possible by washing it by ferric chloride solution at a concentration 0.02-0.05 M and with an equimolar addition of an ammonium chloride. Therewith most efficient methods, which used in-situ conditions, are heap and convection leaching technologies with treatment degree, which not less than 80%. At the same time, the most efficient methods which used in-situ conditions are heap and the convection leaching. The hardware-technological scheme of a convection leaching is presented. Noted that ammonium salts additions slightly rising coefficient of treatment from Sr-90. Because ammonium salts aren’t expensive, their additions allow to obtain significant economic benefits due to decreasing of ferric chloride consumption, which is more valuable, and waste water volume reduction.

  2. Production cross sections of short-lived silver radionuclides from natPd(p,xn) nuclear processes

    International Nuclear Information System (INIS)

    Khandaker, Mayeen Uddin; Kim, Kwangsoo; Kim, Guinyun

    2012-01-01

    Production cross-sections of short-lived 103 Ag, 104m Ag and 104g Ag radionuclides from proton-induced reactions on natural palladium (Pd) were measured up to 41 MeV by using a stacked-foil activation technique combined with high resolution γ-ray spectrometry. The present results are compared with the available literature values as well as theoretical data calculated by the TALYS and the ALICE-IPPE computer codes. Note that production cross-sections of the 104m Ag radionuclide from nat Pd(p,xn) processes has been measured here for the first time. Physical thick target yields for the investigated radionuclides were deduced from the respective threshold energy to 41 MeV taking into account that the total energy is absorbed in the targets. Measured data of the short-lived 103 Ag radionuclide are noteworthy due to its possible applications as a precursor for the indirect production of widely used therapeutic 103 Pd radionuclide via nat Pd(p,xn) 103 Ag → 103 Pd processes. On the other hand, the investigated 104 Ag radionuclide finds importance due to its potential use as a diagnostic and positron emission tomography (PET) imaging analogue. Above all, measured data will enrich the literature database leading to various applications in science and technology.

  3. Biologic considerations in anatomic imaging with radionuclides. Final progress report, July 1974--June 1975

    International Nuclear Information System (INIS)

    Potchen, E.J.

    1975-01-01

    An important task relating to anatomic imaging with radionuclides is the determination of factors which effect the use of imaging procedures. This is important to reduce radiation exposure in the population, to improve the efficacy of diagnostic imaging procedures and finally to provide a basis for evaluating the potential effects of proposed regulation of use rates. In this report we describe a methodology for obtaining clinical data relating to the use of the brain scan in an inner city teaching hospital. The development of a questionnaire suitable for use in a clinical setting and providing both prospective and retrospective data is presented. The results of the use of the questionnaire at the Johns Hopkins Hospital during a three month period in 1974 are shown and discussed. Some preliminary results from these data are given and a method for further analysis is indicated

  4. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  5. Radionuclide generators for biomedical applications

    International Nuclear Information System (INIS)

    Finn, R.D.; Molinski, V.J.; Hupf, H.B.; Kramer, H.

    1983-10-01

    This document reviews the chemical literature of those radionuclide generators that have gained or appear to possess utility in medical imaging. The text represents a conscientious effort to peruse the scientific literature through 1980. The intent of this work is to provide a reference point for the investigator who is interested in the development of a particular generator system and the refinements which have been reported. Moreover, the incorporation of the particular daughter radionuclide into a suitable radiodiagnostic agent is presented

  6. Current technology in sampling for airborne radionuclides

    International Nuclear Information System (INIS)

    Schulte, H.F.

    1976-01-01

    Sampling for airborne radionuclides is an important part of assessing the occupational environment and that of the public or out-plant environment. Both of these are important to the operation of any nuclear facility. Most such facilities do not emit radionuclides continuously to any extent and hence both the occupational and environmental sampling system is designed to detect deviations from normal conditions or untoward events. Work with materials of a low degree of radioactivity or with nonradioactive materials may involve operations which are not enclosed and significant contaminating material may always exist in the air. In this case, the sampling is directed toward measuring this ambient level and assessing its continued impact on the worker and on the environment. Publication No. 12 of the International Commission on Radiological Protection specifies the types of operations where sampling is necessary for worker protection and the American National Standards Institute publication N 13.1-1969 is a guide to the methods used. Increasingly, this field is covered by various regulations which specify when sampling must be done and, in some cases, how it shall be done. These include requirements of the Occupational Safety and Health Administration, the Nuclear Regulatory Commission, and the Environmental Protection Agency. Needless to say, where these have specified methods they must be followed although in most cases exact procedures are not detailed as requirements. Within the plant, needs for sampling are often suggested by surface monitoring results and by bioassay, and outside by analysis of plants, soils, and material from fallout trays. 15 references

  7. The enrichment of natural radionuclides in oil shale-fired power plants in Estonia – The impact of new circulating fluidized bed technology

    International Nuclear Information System (INIS)

    Vaasma, Taavi; Kiisk, Madis; Meriste, Tõnis; Tkaczyk, Alan Henry

    2014-01-01

    Burning oil shale to produce electricity has a dominant position in Estonia's energy sector. Around 90% of the overall electric energy production originates from the Narva Power Plants. The technology in use has been significantly renovated – two older types of pulverized fuel burning (PF) energy production units were replaced with new circulating fluidized bed (CFB) technology. Additional filter systems have been added to PF boilers to reduce emissions. Oil shale contains various amounts of natural radionuclides. These radionuclides concentrate and become enriched in different boiler ash fractions. More volatile isotopes will be partially emitted to the atmosphere via flue gases and fly ash. To our knowledge, there has been no previous study for CFB boiler systems on natural radionuclide enrichment and their atmospheric emissions. Ash samples were collected from Eesti Power Plant's CFB boiler. These samples were processed and analyzed with gamma spectrometry. Activity concentrations (Bq/kg) and enrichment factors were calculated for the 238 U ( 238 U, 226 Ra, 210 Pb) and 232 Th ( 232 Th, 228 Ra) family radionuclides and for 40 K in different CFB boiler ash fractions. Results from the CFB boiler ash sample analysis showed an increase in the activity concentrations and enrichment factors (up to 4.5) from the furnace toward the electrostatic precipitator block. The volatile radionuclide ( 210 Pb and 40 K) activity concentrations in CFB boilers were evenly distributed in finer ash fractions. Activity balance calculations showed discrepancies between input (via oil shale) and output (via ash fractions) activities for some radionuclides ( 238 U, 226 Ra, 210 Pb). This refers to a situation where the missing part of the activity (around 20% for these radionuclides) is emitted to the atmosphere. Also different behavior patterns were detected for the two Ra isotopes, 226 Ra and 228 Ra. A part of 226 Ra input activity, unlike 228 Ra, was undetectable in the solid

  8. Stochastic analysis of radionuclide migration in saturated-unsaturated soils

    International Nuclear Information System (INIS)

    Kawanishi, Moto

    1988-01-01

    In Japan, LLRW (low level radioactive wastes) generated from nuclear power plants shall be started to store concentrically in the Shimokita site from 1990, and those could be transformed into land disposal if the positive safety is confirmed. Therefore, it is hoped that the safety assessment method shall be successed for the land disposal of LLRW. In this study, a stochastic model to analyze the radionuclide migration in saturated-unsaturated soils was constructed. The principal results are summarized as follows. 1) We presented a generalized idea for the modeling of the radionuclide migration in saturated-unsaturated soils as an advective-dispersion phenomena followed by the decay of radionuclides and those adsorption/desorption in soils. 2) Based on the radionuclide migration model mentioned above, we developed a stochastic analysis model on radionuclide migration in saturated-unsaturated soils. 3) From the comparison between the simulated results and the exact solution on a few simple one-dimensional advective-dispersion problems of radionuclides, the good validity of this model was confirmed. 4) From the comparison between the simulated results by this model and the experimental results of radionuclide migration in a one-dimensional unsaturated soil column with rainfall, the good applicability was shown. 5) As the stochastic model such as this has several advantages that it is easily able to represent the image of physical phenomena and has basically no numerical dissipation, this model should be more applicable to the analysis of the complicated radionuclide migration in saturated-unsaturated soils. (author)

  9. Modelling the impact of discharges of technologically enhanced natural series radionuclides in the marine environment

    International Nuclear Information System (INIS)

    Scott, E.M.; Baxter, M.S.

    1997-01-01

    Natural radionuclides are used within the marine environment to study particle associated processes such as scavenging and sedimentary re-working (Th-234) and to date events and measure rates (Pb-210). In addition, Po-210 has been shown to make a significant contribution to the collective dose of the world population through consumption of marine products (fish). The interpretation of observed activity ratios in the environment is presented, based on earlier description. The natural marine system may however undergo a number of disturbances on a local scale due to discharges of technologically enhanced radionuclides from industrial processes such as phosphate ore processing and scaling in oil and gas production. Some work done to extend the original Bateman equations is shown to describe the behaviour of a decay series under a number of different types of perturbations, and the approach is demonstrated through simulation of a simple system. (author)

  10. External accumulation of radionuclide in hepatic hydrothorax

    International Nuclear Information System (INIS)

    Albin, R.J.; Johnston, G.S.

    1989-01-01

    Hepatic hydrothorax is a complication in approximately 5% of patients with cirrhosis. Ascites is almost always present and helps to suggest the correct diagnosis. However, when ascites is absent, radionuclide imaging has proven to be helpful in establishing that the pleural effusion originated from ascitic fluid. When pleural fluid is rapidly removed, such as by thoracostomy tube drainage, the radioisotope may accumulate outside the thorax and produce a negative scan of the chest. When the radionuclide scan is nondiagnostic and the pleural space is being rapidly drained, the pleural fluid collecting system should always be imaged before rejecting a diagnosis of hepatic hydrothorax

  11. Development of a transportable system for radionuclide analysis

    International Nuclear Information System (INIS)

    Cunningham, W.C.; Anderson, D.L.; Lamont, W.H.; South, P.K.; Rury, M.A.; Beachley, G.M.; Ondov, J.M.

    2008-01-01

    Transportable radioanalytical systems were assembled and tested for quantitative determination of γ-emitting radionuclides and screening of β- emitting radionuclides. Standard operating procedures (SOPs), including instructions for assembly, disassembly, operation, sample collection and analysis, and all other procedures needed, were developed. Foods, as well as National Institute of Standards and Technology, International Atomic Energy Agency, and in-house Reference Materials were analyzed. An SOP for γ-emitting radionuclides was successfully tested at 3 locations. (author)

  12. Proceedings of Soil Decon `93: Technology targeting radionuclides and heavy metals

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The principal objective for convening this workshop was to exchange ideas and discuss with scientists and engineers methods for removing radionuclides and/or toxic metals from soils. Over the years there have been numerous symposia, conferences, and workshops directed at soil remediation. However, this may be the first where the scope was narrowed to the removal of radionuclides and toxic metals from soils. The intent was to focus on the separation processes controlling the removal of the radionuclide and/or metal from soil. Its purpose was not intended to be a soil washing/leaching workshop, but rather to identify a variety or combination of processes (chemical, physical, and biological) that can be used in concert with the applicable engineering approaches to decontaminate soils of radionuclides and toxic metals. Abstracts and visual aids used by the speakers of the workshop are presented in this document.

  13. Proceedings of Soil Decon '93: Technology targeting radionuclides and heavy metals

    International Nuclear Information System (INIS)

    1993-09-01

    The principal objective for convening this workshop was to exchange ideas and discuss with scientists and engineers methods for removing radionuclides and/or toxic metals from soils. Over the years there have been numerous symposia, conferences, and workshops directed at soil remediation. However, this may be the first where the scope was narrowed to the removal of radionuclides and toxic metals from soils. The intent was to focus on the separation processes controlling the removal of the radionuclide and/or metal from soil. Its purpose was not intended to be a soil washing/leaching workshop, but rather to identify a variety or combination of processes (chemical, physical, and biological) that can be used in concert with the applicable engineering approaches to decontaminate soils of radionuclides and toxic metals. Abstracts and visual aids used by the speakers of the workshop are presented in this document

  14. Medical technology update - a Canadian perspective

    International Nuclear Information System (INIS)

    Lee, J.

    2005-01-01

    Major advances in medical equipment and the expanding utility of clinical applications have contributed to imaging procedures fast becoming an integral part of standard patient care in hospitals and clinics worldwide. The medical imaging market is based on the integration of at least three critical market segments using cutting-edge technologies: Image-generating equipment; contrast agents and imaging labels, including radionuclides; and associated hardware and software to process, evaluate, store, and transmit the images, which are either digitally generated or digitized from conventional film. (author)

  15. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murphy, W.A.

    1988-01-01

    After only a few years, MR imaging has proved to be an important method for imaging disorders of the musculoskeletal tissues. The images are characterized by great inherent contrast, excellent spatial resolution, and exquisite anatomic display - major reasons why MR imaging compares favorably with other imaging methods, such as radionuclide bone scanning and CT. MR imaging is particularly sensitive to bone marrow alterations and is very effective for detection and characterization of a wide variety of soft tissue conditions. Advances in surface coil technology will increase the usefulness of MR imaging in the evaluation of articular disease. In addition, chemical shift imaging and spectroscopy will add physiologic information to the anatomic features demonstrated by proton imaging

  16. Research on the assessment technology of the radionuclide inventory for the radioactive waste disposal

    International Nuclear Information System (INIS)

    Lee, K. J.; Song, M. C.; Hwang, G. H.; Lee, C. M.; Yuk, D. S.; Lee, S. C.

    2004-02-01

    The contents and the scope of this study are as follows : reassessment of selection criteria and final selection of target radionuclides, establishment of detailed radionuclide evaluation methods for each target radionuclide, development of requirement and fulfillment guidelines for the assessment methods of the assay-target radionuclide inventory

  17. Research on the assessment technology of the radionuclide inventory for the radioactive waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. J.; Song, M. C.; Hwang, G. H.; Lee, C. M.; Yuk, D. S.; Lee, S. C. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2004-02-15

    The contents and the scope of this study are as follows : reassessment of selection criteria and final selection of target radionuclides, establishment of detailed radionuclide evaluation methods for each target radionuclide, development of requirement and fulfillment guidelines for the assessment methods of the assay-target radionuclide inventory.

  18. Activation cross sections for the generation of long-lived radionuclides of importance in fusion reactor technology

    International Nuclear Information System (INIS)

    Wang Dahai

    1990-01-01

    The proceedings contain the progress reports of the Coordinated Research Programme to measure and evaluate the activation cross sections for the generation of long-lived radionuclides of importance in fusion reactor technology and the contributed papers (9) presented at the Consultants' Meeting held at Argonne National Laboratory between 11-12 September 1989. A separate abstract was prepared for each paper. Refs, figs and tabs

  19. Detector technology challenges for nuclear medicine and PET

    International Nuclear Information System (INIS)

    Marsden, P.K.

    2003-01-01

    The challenges facing the development of new detector technology for single photon imaging and positron emission tomography (PET) are considered. There is currently great interest in functional imaging with radionuclides, particularly PET, triggered by new clinical applications and developments in molecular and cell biology. Multi-modality systems that combine radionuclide imaging with CT present new challenges, as do very high resolution systems for imaging small animals. Whilst for PET there are some fairly well defined routes to improving performance, the basic design of single photon systems has remained unchanged for many years. This review outlines the challenges that must be addressed by detector physicists in order to obtain significant advances in performance, and indicates some of the approaches currently being adopted. Emphasis is given to PET which is where the greatest opportunities appear to lie

  20. Modeling Radionuclide Decay Chain Migration Using HYDROGEOCHEM

    Science.gov (United States)

    Lin, T. C.; Tsai, C. H.; Lai, K. H.; Chen, J. S.

    2014-12-01

    Nuclear technology has been employed for energy production for several decades. Although people receive many benefits from nuclear energy, there are inevitably environmental pollutions as well as human health threats posed by the radioactive materials releases from nuclear waste disposed in geological repositories or accidental releases of radionuclides from nuclear facilities. Theoretical studies have been undertaken to understand the transport of radionuclides in subsurface environments because that the radionuclide transport in groundwater is one of the main pathway in exposure scenarios for the intake of radionuclides. The radionuclide transport in groundwater can be predicted using analytical solution as well as numerical models. In this study, we simulate the transport of the radionuclide decay chain using HYDROGEOCHEM. The simulated results are verified against the analytical solution available in the literature. Excellent agreements between the numerical simulation and the analytical are observed for a wide spectrum of concentration. HYDROGECHEM is a useful tool assessing the ecological and environmental impact of the accidental radionuclide releases such as the Fukushima nuclear disaster where multiple radionuclides leaked through the reactor, subsequently contaminating the local groundwater and ocean seawater in the vicinity of the nuclear plant.

  1. The enrichment behavior of natural radionuclides in pulverized oil shale-fired power plants

    International Nuclear Information System (INIS)

    Vaasma, Taavi; Kiisk, Madis; Meriste, Tõnis; Tkaczyk, Alan Henry

    2014-01-01

    The oil shale industry is the largest producer of NORM (Naturally Occurring Radioactive Material) waste in Estonia. Approximately 11–12 million tons of oil shale containing various amounts of natural radionuclides is burned annually in the Narva oil shale-fired power plants, which accounts for approximately 90% of Estonian electricity production. The radionuclide behavior characteristics change during the fuel combustion process, which redistributes the radionuclides between different ash fractions. Out of 24 operational boilers in the power plants, four use circulating fluidized bed (CFB) technology and twenty use pulverized fuel (PF) technology. Over the past decade, the PF boilers have been renovated, with the main objective to increase the efficiency of the filter systems. Between 2009 and 2012, electrostatic precipitators (ESP) in four PF energy blocks were replaced with novel integrated desulphurization technology (NID) for the efficient removal of fly ash and SO 2 from flue gases. Using gamma spectrometry, activity concentrations and enrichment factors for the 238 U ( 238 U, 226 Ra, 210 Pb) and 232 Th ( 232 Th, 228 Ra) family radionuclides as well as 40 K were measured and analyzed in different PF boiler ash fractions. The radionuclide activity concentrations in the ash samples increased from the furnace toward the back end of the flue gas duct. The highest values in different PF boiler ash fractions were in the last field of the ESP and in the NID ash, where radionuclide enrichment factors were up to 4.2 and 3.3, respectively. The acquired and analyzed data on radionuclide activity concentrations in different PF boiler ashes (operating with an ESP and a NID system) compared to CFB boiler ashes provides an indication that changes in the fuel (oil shale) composition and boiler working parameters, as well as technological enhancements in Estonian oil shale fired power plants, have had a combined effect on the distribution patterns of natural radionuclides in

  2. Radiochemical schemes of obtaining 89Sr and 90Y radionuclides

    International Nuclear Information System (INIS)

    Usarov, Z. O.

    2010-03-01

    Key words: strontium-89, yttrium-90, extraction and extraction-chromatographic purification of radionuclides, radiopharmaceuticals. Subjects of research: strontium-89 and yttrium-90 radionuclides and their chloride forms. Purpose of work is developing of radiochemical technologies on obtaining of 89 Sr and 90 Y on the WWR-SM reactor with high radionuclide purity. Methods of research: extraction and extraction-chromatographic methods of radionuclides separation, beta- and gamma-spectrometric methods of activity measuring. The results obtained and their novelty: Were determined the conformity to laws of Y and Sr distribution in two-phase systems TBP-HNO 3 , TBP-NH 4 NO 3 , TBP-HCI, HDEHP-NO 3 , HDEHP-NH 4 NO 3 and HDEHP-HCI. Were determined the conformity to laws of Y and Sr distribution in systems with craun ethers DB-18K-6 and DTBDB-18K-6 from water solutions of HNO 3 . Radiochemical technologies on obtaining of 89 Sr and 90 Y radionuclides including radiochemical process of yttrium target with using the systems TBP-HNO 3 and HDEHP/Teflone were developed. Practical value: the radiochemical technology of obtaining 89 Sr with high radionuclide purity was developed. The method of preparation a chloride compound of 89 SrCl 2 which is used as a drug form for preparation of 89 Sr- 'Metastron' was developed. The relatively simple method of on the way obtaining 90 Y in the reactor with high radionuclidic purity that is useful for follow using in medical practice was offered. Degree of embed and economic effectivity: the developed technologies have approbation in manufacturing conditions in Radiopreparat Enterprise of INP AS RU and were offered for receiving of domestic preparations against of import foreign analogues. The statement about using the invention by obtained patent is attached to dissertation. Field of application: the received results will be introduced in manufacture at Radiopreparat Enterprise of INP AS RU for receiving of domestic preparations

  3. Development of long-lived radionuclide partitioning technology

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Hyung; Lee, Eil Hee; Kim, Kwang Wook; Yang, Han Beom; Chung, Dong Yong; Lim, Jae Kwan; Shin, Young Jun; Kim, Heung Ho; Kown, Sun Gil; Kim, Young Hwan; Hwang, Doo Seung

    1996-07-01

    This study has been focused on the development of unit processes for partitioning in the 1st stage, and experimentally carried out to examine the separation characteristics and operation conditions on the following unit processes. (1) Removal of a small amount of uranium by extraction with TBP, (2) Removal of Zr and Mo and destruction of nitric acid by uranium by denitration with formic acid, (3) Co-precipitation of Am, Np and RE oxalic acid, (4) Dissolution and destruction of oxalate by hydrogen peroxide, (5) Co-extraction of Am, Np and RE by nitric acid, (8) Back-extraction of Np by oxalic acid, (9) Adsorption and elution of Cs and Sr by zeolite, and (10) Advanced separation of radionuclide by electrochemical REDOX method. The results obtained from each unit process will be use as the basic materials for the establishment of optimal partitioning and design of process equipment. (author). 46 refs., 54 tabs., 222 figs.

  4. Assessment of waste management of volatile radionuclides

    International Nuclear Information System (INIS)

    Altomare, P.M.; Barbier, M.; Lord, N.; Nainan, D.

    1979-05-01

    This document presents a review of the Technologies for Waste Management of the Volatile Radionuclides of iodine-129, krypton-85, tritium, and carbon-14. The report presents an estimate of the quantities of these volatile radionuclides as are produced in the nuclear power industry. The various technologies as may be used, or which are under investigation, to immobilize these nuclides and to contain them during storage and in disposal are discussed. Also, the alternative disposal options as may be applied to isolate these radioactive wastes from the human environment are presented. The report contains information which was available through approximately January 1978

  5. Advances in study of perpes simplex virus type 1-thymidine kinase reporter gene imaging

    International Nuclear Information System (INIS)

    Liu Ying; Lan Xiaoli; Zhang Yongxue

    2007-01-01

    Radionuclide reporter gene imaging is an effect way to provide qualitative and quantitative information for gene therapy. There are three systems of reporter gene including kinase reporter gene. perpes simplex virus type 1-thymidine kinase (HSV1-tk) has perfect physical and chemical characteristic which is suit for imaging as reporter gene. It has been widely investigated and intensively researched. Two substrates of HSV1-tk are purine nucleosite derivant and acyclovir derivant, which can also be used as reporter probes of HSV1-tk. (authors)

  6. Estimation of total error in DWPF reported radionuclide inventories. Revision 1

    International Nuclear Information System (INIS)

    Edwards, T.B.

    1995-01-01

    The Defense Waste Processing Facility (DWPF) at the Savannah River Site is required to determine and report the radionuclide inventory of its glass product. For each macro-batch, the DWPF will report both the total amount (in curies) of each reportable radionuclide and the average concentration (in curies/gram of glass) of each reportable radionuclide. The DWPF is to provide the estimated error of these reported values of its radionuclide inventory as well. The objective of this document is to provide a framework for determining the estimated error in DWPF's reporting of these radionuclide inventories. This report investigates the impact of random errors due to measurement and sampling on the total amount of each reportable radionuclide in a given macro-batch. In addition, the impact of these measurement and sampling errors and process variation are evaluated to determine the uncertainty in the reported average concentrations of radionuclides in DWPF's filled canister inventory resulting from each macro-batch

  7. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  8. Prediction of standard-dose brain PET image by using MRI and low-dose brain ["1"8F]FDG PET images

    International Nuclear Information System (INIS)

    Kang, Jiayin; Gao, Yaozong; Shi, Feng; Lalush, David S.; Lin, Weili; Shen, Dinggang

    2015-01-01

    Purpose: Positron emission tomography (PET) is a nuclear medical imaging technology that produces 3D images reflecting tissue metabolic activity in human body. PET has been widely used in various clinical applications, such as in diagnosis of brain disorders. High-quality PET images play an essential role in diagnosing brain diseases/disorders. In practice, in order to obtain high-quality PET images, a standard-dose radionuclide (tracer) needs to be used and injected into a living body. As a result, it will inevitably increase the patient’s exposure to radiation. One solution to solve this problem is predicting standard-dose PET images using low-dose PET images. As yet, no previous studies with this approach have been reported. Accordingly, in this paper, the authors propose a regression forest based framework for predicting a standard-dose brain ["1"8F]FDG PET image by using a low-dose brain ["1"8F]FDG PET image and its corresponding magnetic resonance imaging (MRI) image. Methods: The authors employ a regression forest for predicting the standard-dose brain ["1"8F]FDG PET image by low-dose brain ["1"8F]FDG PET and MRI images. Specifically, the proposed method consists of two main steps. First, based on the segmented brain tissues (i.e., cerebrospinal fluid, gray matter, and white matter) in the MRI image, the authors extract features for each patch in the brain image from both low-dose PET and MRI images to build tissue-specific models that can be used to initially predict standard-dose brain ["1"8F]FDG PET images. Second, an iterative refinement strategy, via estimating the predicted image difference, is used to further improve the prediction accuracy. Results: The authors evaluated their algorithm on a brain dataset, consisting of 11 subjects with MRI, low-dose PET, and standard-dose PET images, using leave-one-out cross-validations. The proposed algorithm gives promising results with well-estimated standard-dose brain ["1"8F]FDG PET image and substantially

  9. Intravenous streptokinase therapy in acute myocardial infarction: Assessment of therapy effects by quantitative 201Tl myocardial imaging (including SPECT) and radionuclide ventriculography

    International Nuclear Information System (INIS)

    Koehn, H.; Bialonczyk, C.; Mostbeck, A.; Frohner, K.; Unger, G.; Steinbach, K.

    1984-01-01

    To evaluate a potential beneficial effect of systemic streptokinase therapy in acute myocardial infarction, 36 patients treated with streptokinase intravenously were assessed by radionuclide ventriculography and quantitative 201 Tl myocardial imaging (including SPECT) in comparison with 18 conventionally treated patients. Patients after thrombolysis had significantly higher EF, PFR, and PER as well as fewer wall motion abnormalities compared with controls. These differences were also observed in the subset of patients with anterior wall infarction (AMI), but not in patients with inferior wall infarction (IMI). Quantitative 201 Tl imaging demonstrated significantly smaller percent myocardial defects and fewer pathological stress segments in patients with thrombolysis compared with controls. The same differences were also found in both AMI and IMI patients. Our data suggest a favorable effect of intravenous streptokinase on recovery of left ventricular function and myocardial salvage. Radionuclide ventriculography and quantitative 201 Tl myocardial imaging seem to be reliable tools for objective assessment of therapy effects. (orig.)

  10. Technology of DTPA and immunoglobulins conjugation and their attachment to 90Y and 177Lu radionuclides

    International Nuclear Information System (INIS)

    Rekova, M.; Jedinakova-Krizova, V.

    2010-01-01

    The aim of the study of labeling of ligand-antibody conjugates was to find optimal conditions of preparing of these conjugates and appropriate radioactivity of selected nuclide for applications in nuclear medicine. Conjugation of the γ-immunoglobulin G (human or bovine IgG, polyclonal antibodies) and bifunctional chelating agent, diethylenetriaminepentaacetic acid dianhydride (cDTPAA), was carried out. Various values of the cDTPAA/antibody ratio, the weight concentration of polyclonal or monoclonal antibodies (MEM-97) and buffers were used. Further, the labeling conditions of the DTPA-IgG conjugate by radionuclides 90 Y and 177 Lu were optimized, and the labeling yield and the conjugation ratio of prepared radionuclide-DTPA-IgG conjugates was determined. Optimal incubation time of the immunoglobulin conjugation was obtained at 30 min from mixing of individual components. The labeling yield of radionuclide-DTPA-antibody conjugate higher than 95% was achieved. Higher values of conjugation ratio of radionuclide-DTPA-antibody conjugate were achieved in 0.1 mol L -1 carbonate buffer, pH 8.5, and the 0.1 mol L -1 carbonate buffer is suitable for studied conjugation systems. This study showed that the labeling yield as well as the conjugation ratio of tested systems depend on the amount of antibody substance, bifunctional chelating agent/antibody molar ratio and pH value of the buffer used. (author)

  11. Sorption of radionuclides from Pb-Bi melt. Report 1

    International Nuclear Information System (INIS)

    Konovalov, Eh.E.; Il'icheva, N.S.; Trifonova, O.E.

    2015-01-01

    Results of laboratory investigations of sorption and interfacial distribution of 54 Mn, 59 Fe, 60 Co, 106 Ru, 125 Sb, 137 Cs, 144 Ce, 154,155 Eu and 235,238 U radionuclides in the system Pb-Bi melt - steel surface are analyzed. It is shown that 106 Ru and 125 Sb are concentrated in Pb-Bi melt and other radionuclides with higher oxygen affinity are sorbed on oxide deposits on structural materials. Temperature dependences of sorption efficiency of radionuclides are studied. It is shown that there is sharp increase of this value for all radionuclides near the temperature range 350-400 deg C. Recommendations are given on the use of 106 Ru and 125 Sb as a reference for fuel element rupture detection system with radiometric monitoring of coolant melt samples and 137 Cs, 134 Cs, 134m Cs with radiometric monitoring of sorbing samples [ru

  12. The behaviour of trace elements and radionuclides in must of grapes during fermentation and usual wine technology

    International Nuclear Information System (INIS)

    Hellmuth, K.H.; Fischer, E.

    1985-01-01

    The elements Co(II), Sr(II), Cs(I), Tl(I) and Am(III) were added as their radionuclides to the must of white grapes of one vintage and from that wine was prepared using usual wine technology. The elimination of the elements during the fermentation and as a consequence of the subsequent treatments has been determined. The decrease of the metal contents with time follows approximately an exponential function in the cases of Co, Cs, Tl and Am, whereas the Sr-content remains nearly constant. In the total balance, the following residual values were found in the final wine: Co 8.6+-0.6%, Sr 41+-4%, Cs 0.13+-0.07 resp. 0.031+-0.008%, Tl 1.3+-0.2% and Am 1.0+-0.2% of the initial value. (orig./PW) [de

  13. Radionuclide studies for malignant hepatic and splenic disease

    International Nuclear Information System (INIS)

    Drum, D.E.; Royal, H.D.

    1986-01-01

    For many years radionuclide studies have afforded an invaluable aid to clinicians for the detection and management of malignant tumors of the liver. Alternative methods for producing images of the liver are now available to the radiologist, and each technique has exhibited a variety of useful and limiting features. In an effort to clarify and guide choices about applications of all radiological techniques, our department recently developed a monograph describing algorithms for optimal use of all imaging modalities by referring physicians. The approach to detection of hepatic metastases illustrates in a correlative way applications of radioisotope imaging in such patients. As presented, the algorithm is neither identical to nor unlike those recommended or published elsewhere. This chapter reviews the major applications of radionuclide imaging for metastatic cancer of liver with close attention to the clinician's point of view

  14. Entrapment of Radionuclides in Nanoparticle Compositions

    DEFF Research Database (Denmark)

    2012-01-01

    The present invention is directed to the technical field of imaging compositions useful for diagnosing cancer and other diseases in a subject. In particular, the invention relates to a class of diagnostic compounds comprising a novel liposome composition with encapsulated metal entities such as r...... tissue and, in general, pathological conditions associated with leaky blood vessels. The present invention provides a new diagnostic tool for the utilization of positron emission tomography (PET) imaging technique.......The present invention is directed to the technical field of imaging compositions useful for diagnosing cancer and other diseases in a subject. In particular, the invention relates to a class of diagnostic compounds comprising a novel liposome composition with encapsulated metal entities...... such as radionuclides,for example 61Cu and 64Cu copper isotopes. The invention further relates to a novel method for loading delivery systems, such as liposome compositions, with metal entities such as radionuclides, and the use of liposomes for targeted diagnosis and treatment of a target site, such as cancerous...

  15. Potential clinical impact of radionuclide imaging technologies: highlights of the ITBS 2003 meeting

    Energy Technology Data Exchange (ETDEWEB)

    Itti, Roland E-mail: roland.itti@univ-lyon1.fr

    2004-07-11

    Radiopharmaceuticals are major determinants of progress in Nuclear Medicine. Besides {sup 18}FDG, the most common PET tracer, several other molecules are under evaluation, such as {sup 18}F-fluoride for bone studies, numerous ligands for neurotransmission, {sup 18}F-DOPA for neuro-endocrine tumors or generator produced {sup 68}Ga-peptides for various cancers. Nuclear medicine gradually changes for 'molecular imaging' and medical imaging, which was at the beginning mainly anatomic, has progressed in the direction of functional and metabolic imaging. The present challenge is to achieve some degree of 'in vivo' biochemistry or even histology or genetics. The importance of anatomic/functional image fusion justifies the development of combined PET-CT instrumentation, whose objectives have to be discussed in terms of anatomical landmarks and/or additional clinical information. The question of 'hard' or 'soft' image co-registration remains open, involving not only CT, but also SPECT or MRI. Development of dedicated imaging devices, whether single photon or positron, is of major interest for breast imaging, allowing optimal imaging conditions, with results definitely superior to classical gamma-cameras or PET. The patient population concerned with scintimammography is still controversial, as well as the imaging modalities: FDG or sestaMIBI, planar or tomographic, scintillators or semi-conductors, and the research field remains open. This is also valid for external or per-operative probe systems for tumor or lymph nodes localization.

  16. The removal of radionuclides from foodstuffs during technological treatment and culinary processing

    International Nuclear Information System (INIS)

    Perepelyatnikova, L.V.; Lazarev, N.M.; Ivanova, T.N.; Fedin, F.A.; Long, S.; Pollard, D.

    1996-01-01

    Comparative data on the efficiency of industrial and domestic processing techniques of plant and animal products, which reduce radionuclides content foodstuffs, are summarized. Methods, which provide the greatest decrease of radionuclides content in the final products with minimum losses of nutritional value, were identified

  17. Three-dimensional imaging technology offers promise in medicine.

    Science.gov (United States)

    Karako, Kenji; Wu, Qiong; Gao, Jianjun

    2014-04-01

    Medical imaging plays an increasingly important role in the diagnosis and treatment of disease. Currently, medical equipment mainly has two-dimensional (2D) imaging systems. Although this conventional imaging largely satisfies clinical requirements, it cannot depict pathologic changes in 3 dimensions. The development of three-dimensional (3D) imaging technology has encouraged advances in medical imaging. Three-dimensional imaging technology offers doctors much more information on a pathology than 2D imaging, thus significantly improving diagnostic capability and the quality of treatment. Moreover, the combination of 3D imaging with augmented reality significantly improves surgical navigation process. The advantages of 3D imaging technology have made it an important component of technological progress in the field of medical imaging.

  18. Radiolabelled antibodies in imaging

    International Nuclear Information System (INIS)

    Khaw, B.A.; Haber, E.

    1982-01-01

    Recent technological advances make it possible to produce pure (monoclonal) antibodies in unlimited quantities without the need for continuous immunization of animals and to label these antibodies with a variety of radionuclides which can be traced by single-photon computed tomography. An outline review of the state of the art is presented, with particular reference to the imaging of myocardial infarcts and to tumour imaging studies using labelled monoclonal antibodies (sup(99m)Tc and 125 I). Lengthy bibliography. (U.K.)

  19. Importance of biota in radionuclide transport at the SL-1 radioactive waste disposal area

    International Nuclear Information System (INIS)

    Arthur, W.J.; Grant, J.C.; Markham, O.D.

    1983-01-01

    During summer 1981 and 1982, radioecological research was conducted at the Stationary Low Power Reactor-1 radioactive waste disposal area to: (1) identify vegetation, wildlife, and invertebrate species occurring at or using the area; (2) determine radionuclide concentrations in these various ecosystem components; and (3) to evaluate their respective roles in radionuclide uptake and transport through the surrounding environment. Cesium-137 concentrations detected in surface soils, small mammal excavated soils and small mammal tissues collected at the waste disposal site were significantly (P less than or equal to 0.05) greater than control area samples. Strontium-90 and 235 U analyses of SL-1 and control area samples and projections of total mass of ecosystem components in SL-1 area will be completed in summer of 1983 at which time estimates will be made on the total quantity of fission and activation radionuclides occurring in ecological media at the SL-1 waste disposal area

  20. From molecular imaging to personalized radionuclide therapy of cancer

    International Nuclear Information System (INIS)

    Baum, R.P.

    2015-01-01

    Full text of publication follows. 68 Gallium is a positron emitter (t 1/2 68 min) which can be produced from a generator in a convenient, 'in-house' preparation and used for labeling of peptides, e.g. somatostatin analogues (SA) like DOTATOC or DOTATATE for molecular imaging of SSTR expressing tumors. Since 2004, we have performed over 7700 68 Ga PET/CT studies in patients with neuroendocrine tumors (NET) and have established SSTR PET/CT as the new gold standard for imaging G1 and G2 NET (staging, re-staging, therapy response evaluation and detection of unknown primary NET). The same peptides can be labeled with 177 Lutetium or 90 Yttrium for radionuclide therapy, a form of personalized treatment (THERANOSTICS approach). PRRNT is based on the receptor-mediated internalization of SA. Several clinical trials indicate that PRRNT can deliver effective radiation doses to tumors. A German multi-institutional registry study with prospective follow up in 450 patients indicates that PRRT is an effective therapy for patients with G1-2 neuroendocrine tumors, irrespective of previous therapies, with a survival advantage of several years compared to other therapies and only minor side effects. Median overall survival (OS) of all patients from the start of treatment was 59 months. Median progression-free survival (PFS) measured from last cycle of therapy accounted to 41 mo. Median PFS of pancreatic NET was 39 mo. Similar results were obtained for NET of unknown primary (median PFS: 38 mo) whereas NET of small bowel had a median PFS of 51 months. Side effects like 3-4 NEThro- or hemato-toxicity were observed in only 0.2% and 2% of patients respectively. PRRNT is highly effective in the management of NET, even in advanced cases. In patients with progressive neuroendocrine tumors, fractionated, personalized PRRNT with lower doses of radioactivity given over a longer period of time (Bad Berka Concept using sequential (DUO) PRRNT) results in excellent therapeutic responses

  1. Chapter 2. Radionuclides in the biosphere

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with role of radionuclides in the biosphere. Chapter consists of next parts: (1) Natural radionuclides in biosphere; (2) Man-made radionuclides in the biosphere; (3) Ecologically important radionuclides; (4) Natural background; (5) Radiotoxicity and (6) Paths of transfer of radionuclides from the source to human

  2. Radionuclide imaging of the lower genitourinary tract

    International Nuclear Information System (INIS)

    Lowery, P.A.; Pjura, G.A.; Kin, E.E.; Brown, W.D.

    1988-01-01

    The major use of radionuclide cystography is in the management of children with vesicoureteral reflux (VUR). Reflux is common, occurring in one-third to one-half of children with urinary tract infection. The significance of VUR lies in its associated symptoms and consequences, which include impaired renal growth and function, vague ill health, renal pain, and more importantly the development of reflux nephropathy, a significant cause of end-stage renal disease and hypertension in children. Although reflux may resolve spontaneously, particularly milder degrees of reflux, the age at which this may occur is unpredictable and repeated follow-up cystography over a number of years may be necessary. Therefore, it is important to minimize radiation to the child while providing accurate diagnostic information. This paper discusses how the technique of radionuclide cystography compares favorably with routine contrast voiding cystourethrography (VCUG) in these respects, and in addition can provide quantitative information not obtained by radiographic techniques. Other indications may include screening siblings of patients known to have reflux, follow-up of antireflux surgery and occasionally screening for reflux in children who have had urinary tract infection

  3. Labeling of DOTA-conjugated HPMA-based polymers with trivalent metallic radionuclides for molecular imaging.

    Science.gov (United States)

    Eppard, Elisabeth; de la Fuente, Ana; Mohr, Nicole; Allmeroth, Mareli; Zentel, Rudolf; Miederer, Matthias; Pektor, Stefanie; Rösch, Frank

    2018-02-27

    In this work, the in vitro and in vivo stabilities and the pharmacology of HPMA-made homopolymers were studied by means of radiometal-labeled derivatives. Aiming to identify the fewer amount and the optimal DOTA-linker structure that provides quantitative labeling yields, diverse DOTA-linker systems were conjugated in different amounts to HPMA homopolymers to coordinate trivalent radiometals Me(III)* = gallium-68, scandium-44, and lutetium-177. Short linkers and as low as 1.6% DOTA were enough to obtain labeling yields > 90%. Alkoxy linkers generally exhibited lower labeling yields than alkane analogues despite of similar chain length and DOTA incorporation rate. High stability of the radiolabel in all examined solutions was observed for all conjugates. Labeling with scandium-44 allowed for in vivo PET imaging and ex vivo measurements of organ distribution for up to 24 h. This study confirms the principle applicability of DOTA-HPMA conjugates for labeling with different trivalent metallic radionuclides allowing for diagnosis and therapy.

  4. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  5. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  6. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    International Nuclear Information System (INIS)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; Bondt, Pieter De; Buechel, Ronny R.; Kaufmann, Philip A.; Cuocolo, Alberto; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J.H.A.; Slart, Riemer H.J.A.; Traegaardh, Elin; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015 0 7 E ANM F INAL myocardial p erfusion g uideline.pdf. (orig.)

  7. Clinical significant of three phase radionuclide bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Suh, Jin Suck; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-04-15

    Three phase radionuclide bone scan, consisting of a radionuclide angiogram, an immediate postinjection blood pool image, and 4hr delayed images, was randomly performed in 182 patients, who had been suffered from either local pain or tenderness. Authors analysed 3 phase bone scan in 74 patients with correct diagnosis proven surgically or clinically, from July 1987 to August, 1988. The results were as follows: 1. Overall sensitivity of 3 phase bone scan was 85.4%: sensitivity in patients with an osseous lesion was 90.4% as opposed to 72.7% in patients with a nonosseous lesion. 2. There was no difference in the detection rate of the osseous lesions between the 3 phase bone scan and the delayed image bone scan. However, because the detection rate was higher on the 3 phase bone scan than it was on only the delayed image bone scan (55%) in instance of the nonosseous lesion, we would suggest that 3 phase bone scan might be obtained in cases suspected of the nonosseous lesions. 3. When the presumptive diagnosis was a bone tumor, sensitivity and specificity for malignancy were 67%, 100% respectively. 4. In differentiating osteomyelitis from cellulitis, sensitivity was 94%, specificity was 100%. 5. 3 phase bone scan was able to provide the precise information about either vasculaturity or localization of lesion in some cases of soft tissue mass and avascular necrosis of hips.

  8. Taking radionuclides to heart

    International Nuclear Information System (INIS)

    Kleynhans, P.H.T.; Lotter, M.G.; Van Aswegen, A.; Minnaar, P.C.; Iturralde, M.; Herbst, C.P.; Marx, D.

    1980-01-01

    Ischaemic heart disease is a main cause of death in South Africa. Non-invasive ECG gated radionuclide bloodpool imaging plays an increasingly useful role in the evalution of the function of the heart as a pump, and the extent of heart muscle perfusion defects is further pinpointed by invasive krypton-81m studies to improve patient management

  9. Application of Java technology in radiation image processing

    International Nuclear Information System (INIS)

    Cheng Weifeng; Li Zheng; Chen Zhiqiang; Zhang Li; Gao Wenhuan

    2002-01-01

    The acquisition and processing of radiation image plays an important role in modern application of civil nuclear technology. The author analyzes the rationale of Java image processing technology which includes Java AWT, Java 2D and JAI. In order to demonstrate applicability of Java technology in field of image processing, examples of application of JAI technology in processing of radiation images of large container have been given

  10. Development of positron emitting radionuclides for imaging with improved positron detectors

    International Nuclear Information System (INIS)

    Yano, Y.

    1976-10-01

    Recent advances in positron cameras and positron ring detectors for transverse section reconstruction have created renewed interest in positron emitting radionuclides. This paper reports on: generator-produced 82 Rb; cyclotron-produced 62 Zn; and reactor-produced 64 Cu. Investigation of the 82 Sr (25 d)-- 82 Rb (75 s) generator determined the elution characteristics for Bio-Rex 70, a weakly acidic carboxylic cation exchanger, using 2% NaCl as the eluent. The yield of 82 Rb and the breakthrough of 82 Sr were determined for newly prepared columns and for long term elution conditions. Spallation-produced 82 Sr was used to charge a compact 82 Rb generator to obtain multi-millicurie amounts of 82 Rb for myocardial imaging. Zinc accumulates in the islet cells of the pancreas and in the prostate. Zinc-62 was produced by protons on Cu foil and separated by column chromatography. Zinc-62 was administered as the amino acid chelates and as the ZnCl 2 to tumor and normal animals. Tissue distribution was determined for various times after intravenous injection. Pancreas-liver images of 62 Zn-histidine uptake were obtained in animals with the gamma camera and the liver uptake of /sup 99m/Tc sulfur colloid was computer subtracted to image the pancreas alone. The positron camera imaged uptake of 62 Zn-histidine in the prostate of a dog at 20 h. 64 Cu was chelated to asparagine, a requirement of leukemic cells, and administered to lymphoma mice. Uptake in tumor and various tissues was determined and compared with the uptake of 67 Ga citrate under the same conditions. 64 Cu-asparagine had better tumor-to-soft tissue ratios than 67 Ga-citrate

  11. Regulatory Technology Development Plan - Sodium Fast Reactor. Mechanistic Source Term - Metal Fuel Radionuclide Release

    International Nuclear Information System (INIS)

    Grabaskas, David; Bucknor, Matthew; Jerden, James

    2016-01-01

    The development of an accurate and defensible mechanistic source term will be vital for the future licensing efforts of metal fuel, pool-type sodium fast reactors. To assist in the creation of a comprehensive mechanistic source term, the current effort sought to estimate the release fraction of radionuclides from metal fuel pins to the primary sodium coolant during fuel pin failures at a variety of temperature conditions. These release estimates were based on the findings of an extensive literature search, which reviewed past experimentation and reactor fuel damage accidents. Data sources for each radionuclide of interest were reviewed to establish release fractions, along with possible release dependencies, and the corresponding uncertainty levels. Although the current knowledge base is substantial, and radionuclide release fractions were established for the elements deemed important for the determination of offsite consequences following a reactor accident, gaps were found pertaining to several radionuclides. First, there is uncertainty regarding the transport behavior of several radionuclides (iodine, barium, strontium, tellurium, and europium) during metal fuel irradiation to high burnup levels. The migration of these radionuclides within the fuel matrix and bond sodium region can greatly affect their release during pin failure incidents. Post-irradiation examination of existing high burnup metal fuel can likely resolve this knowledge gap. Second, data regarding the radionuclide release from molten high burnup metal fuel in sodium is sparse, which makes the assessment of radionuclide release from fuel melting accidents at high fuel burnup levels difficult. This gap could be addressed through fuel melting experimentation with samples from the existing high burnup metal fuel inventory.

  12. Regulatory Technology Development Plan - Sodium Fast Reactor. Mechanistic Source Term - Metal Fuel Radionuclide Release

    Energy Technology Data Exchange (ETDEWEB)

    Grabaskas, David [Argonne National Lab. (ANL), Argonne, IL (United States); Bucknor, Matthew [Argonne National Lab. (ANL), Argonne, IL (United States); Jerden, James [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-02-01

    The development of an accurate and defensible mechanistic source term will be vital for the future licensing efforts of metal fuel, pool-type sodium fast reactors. To assist in the creation of a comprehensive mechanistic source term, the current effort sought to estimate the release fraction of radionuclides from metal fuel pins to the primary sodium coolant during fuel pin failures at a variety of temperature conditions. These release estimates were based on the findings of an extensive literature search, which reviewed past experimentation and reactor fuel damage accidents. Data sources for each radionuclide of interest were reviewed to establish release fractions, along with possible release dependencies, and the corresponding uncertainty levels. Although the current knowledge base is substantial, and radionuclide release fractions were established for the elements deemed important for the determination of offsite consequences following a reactor accident, gaps were found pertaining to several radionuclides. First, there is uncertainty regarding the transport behavior of several radionuclides (iodine, barium, strontium, tellurium, and europium) during metal fuel irradiation to high burnup levels. The migration of these radionuclides within the fuel matrix and bond sodium region can greatly affect their release during pin failure incidents. Post-irradiation examination of existing high burnup metal fuel can likely resolve this knowledge gap. Second, data regarding the radionuclide release from molten high burnup metal fuel in sodium is sparse, which makes the assessment of radionuclide release from fuel melting accidents at high fuel burnup levels difficult. This gap could be addressed through fuel melting experimentation with samples from the existing high burnup metal fuel inventory.

  13. Informal workshop on radionuclide laboratories. Issue 1

    International Nuclear Information System (INIS)

    2001-01-01

    The network of radionuclide stations in the International Monitoring System (IMS) of the Comprehensive Test Ban Treaty (CTBT) will be comprised of 80 monitoring stations and 16 laboratories acting in support of the monitoring stations. The 16 radionuclide laboratories have been designated but there are issues to resolve in several areas: - Fee structure and payments to the laboratories from the PTS; - Agreement on Detailed requirements for certification of the laboratories; - Duties of the laboratory To help provide technical information in these and other areas an Informal Workshop was held on January 29th - February 2nd 2001 at Atomic Weapons Establishment (AWE) United Kingdom. It was agreed that a common fee structure would make for a more efficient operation if one could be agreed. One possible fee structure for payment to the laboratories was considered to be an annual fixed fee for service (estimated at $38,000) plus a charge for each individual analysis (estimated at $1,200). These estimated values were based on the laboratory replies to a questionnaire organised by the PTS in December 2000. An average of 40 samples/year/ laboratory was considered to be the number required to maintain support to the monitoring station network and also maintain the laboratory capability. Based on this number the overall cost, payable to the laboratories, of running a network of 16 radionuclide laboratories was estimated at $1.38M per year, when all 80 radionuclide stations are operational. The first proficiency test exercise had been carried out in November 2000 and was discussed. Overall the results were highly encouraging and any minor problems found were being addressed. The technical areas requiring further consideration were uncertainty values and cascade summing corrections. The basis for an ongoing programme of such exercises was discussed and agreed by participants. One recommendation that came out of this meeting was the desirability of using a common nuclear data

  14. Simulation of radionuclide transport in U.S. agriculture

    International Nuclear Information System (INIS)

    Sharp, R.D.; Baes, C.F. III.

    1982-01-01

    Because of the recent concern about the impact of energy technologies on man and related health effects, there has emerged a need for models to calculate or predict the effects of radionuclides on man. A general overview is presented of a model that calculates the ingrowth of radionuclides into man's food chain. The FORTRAN IV computer program TERRA, Transport of Environmentally Released Radionuclides in Agriculture, simulates the build-up of radionuclides in soil, four plant food compartments, in meat and milk from beef, and in the livestock food compartments that cause radionuclide build-up in milk and meat from beef. A large data set of spatially oriented parameters has been developed in conjunction with TERRA. This direct-access data set is called SITE, Specific Information on the Terrestrial Environment, and contains 35 parameters for each of 3525 half-degree longitude-latitude cells which define the lower 48 states. TERRA and SITE are used together as a package for determining radionuclide concentrations in man's food anywhere within the conterminous 48 states due to atmospheric releases

  15. Current and potential technologies for the detection of radionuclide signatures of proliferation (R and D efforts)

    International Nuclear Information System (INIS)

    Perkins, R.W.; Wogman, N.A.

    1993-03-01

    A country with the goal of developing nuclear weapons could pursue their ambition in several ways. These could range from the purchase or theft of a weapon or of the principal weapons components to a basic development program which may independently produce all the materials and components which are necessary. If the latter approach were pursued, there would be many signatures of such an effort and the more definitive of these include the actual materials which would be produced in each phase of the fuel cycle/weapons production process. By identifying the more definitive signatures and employing appropriate environmental sampling and analysis techniques for their observation, including imaging procedures, it should be possible to detect nuclear proliferation processes. Possible proliferation processes include: uranium acquisition through fuel fabrication; uranium enrichment for weapons production; reactor operation for plutonium production; fuel reprocessing for plutonium extraction; weapons fabrication; and uranium 233 production. Each of these are briefly discussed. The technologies for the detection of proliferation signatures which are in concept or research and development phase are: whole air beta counter; radiokrypton/xenon separator/analyzer; I-129 detector; isotope analyzer; deuterium/tritium analysis by IR/Raman spectroscopy and scintillation counting; noble gas daughter analysis; and airborne radionuclide collector/analyzer

  16. Cenotic and physiological control of the radionuclides migration into system soil-plant

    International Nuclear Information System (INIS)

    Kravets, A.P.

    1998-01-01

    Some biological - cenotic and physiological - factors which determine the availability of radionuclides for a plant and the general capacity for the accumulation of pollutants were investigated and analysed. Metabolites of soil microorganisms and especially root excretion of higher plants increase the rate of destruction of solid forms of pollution and enhance the leaching of radionuclides from the solid matrix. The following facts were demonstrated in the conditions of contamination heterogeneity of Chernobyl fallout: (i) During the period of vegetation the plants of different species of f. Poacea, 1 .5 to 2.7-fold increase in the chemical mobility and biological availability of radionuclides; (ii) Additional increase in the concentration of soil microorganisms (micromycetes) leads to enhanced contents of the mobile form of the pollutant in soil and increases the level of accumulation of the radionuclides by higher plants; (iii) Increase in the density of sowing (and competition, respectively) of the different species of the plants also leads to an enhanced availability of the radionuclides and 1 .7 to 2.4- fold increase in the level of accumulation of the radionuclides by the plants. Other aspect of formation of the level of plant pollution include the peculiarities of radionuclide absorption and accumulation by the plant biomass. The effects of a high density of sowing, high level of the watering and gamma irradiation on the changes in the level of radionuclide accumulation and, at the same time, the cation exchange capacity (CEC) of the plant biomass were investigated in the laboratory and in a greenhouse experiment. In parallel, increased CEC and radionuclide accumulation by a factor of 1.5 to 2.7 was demonstrated. These facts suggest that the biological factors are a powerful tool of control of the pollutants availability and accumulation and may be take into account under development of the modern agricultural technology for clear products formation

  17. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera

    International Nuclear Information System (INIS)

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F.; Erlandsson, Kjell; Waddington, Wendy A.; Ell, Peter J.; Sharir, Tali; Roth, Nathaniel; Berman, Daniel S.

    2010-01-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5±11.8 years of age, 16 men) were injected with 74 MBq of 201 Tl (rest) and 250 MBq 99m Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest 201 Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress 99m Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest 201 Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest 201 Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p 201 Tl D-SPECT acquisition. (orig.)

  18. Preclinical evaluation of "1"1"1In-DOTA-Bombesin analogue for peptide receptor targeted imaging

    International Nuclear Information System (INIS)

    Salgueiro, C.; Castiglia, S.G. de; Tesan, F.; Salgueiro, M.J.

    2017-01-01

    Peptide receptors are very important targets for imaging and therapy. The bombesin family is becoming significant, in special the gastrine-releasing peptide receptor (GRPr) that has been found in Prostate and Breast tumors. The aim of this work is to label [DOTA-Pro1,Tyr4] BN with "1"1"1InCl3 and study its efficacy in normal and tumor animals. Radiolabeling experiences were made to find the best peptide : radionuclide relationship. The radiochemical purity was determined by Sep-pak C18 cartridge (Waters) and ITLC-SG using 50mM EDTA in 0.1M ammonium acetate (pH 5.5) and 3.5%(v/v) ammonia/methanol 1:1. Gamma imaging studies were made 24 hs after injection of the product in control rats. On the other hand gamma imaging studies were made at 24 hs in tumor bearing nude mice too. The tumor was induced by subcutaneous injection of PC3 cells. For biodistribution studies animals were sacrificed and blood, pancreas, intestine, kidneys, liver, lungs, femoral muscle and tumor were analyzed. The results were expressed as %ID/g of tissue. Radiolabeling experiments allowed us to obtain an stable product with >95% of radiochemical purity and 5.78MBq/nmol of specific activity, with a ratio of 13μg peptide per In-111 mCi. The normal and tumor animals imaging show physiological uptake in kidneys and a biodistribution according to bibliography. A specific uptake is evidenced in tumor. Our results show a radiochemical stable compound for 48 hs and suitable for GRPr imaging. (authors) [es

  19. Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    2012-02-16

    The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N{sup 4}-methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the

  20. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

    Science.gov (United States)

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F; Erlandsson, Kjell; Sharir, Tali; Roth, Nathaniel; Waddington, Wendy A; Berman, Daniel S; Ell, Peter J

    2010-08-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, pstress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. Fast and high-quality simultaneous DR MPI is feasible with D-SPECT in a

  1. Improvements in SPECT technology for cerebral imaging

    International Nuclear Information System (INIS)

    Esser, P.D.

    1985-01-01

    Advancement in three major areas of SPECT (single photon emission computed tomography) technology have resulted in improved image quality for cerebral studies. In the first area, single-crystal camera electronics, extensive use of microprocessors, custom digital circuitry, an data bus architecture have allowed precise external control of all gantry motions and improved signal processing. The new digital circuitry permits energy, uniformity, and linearity corrections to be an integral part of the processing electronics. Calibration of these correlations is controlled by algorithms stored in the camera's memory. The second area of improved SPECT technology is camera collimation and related imaging techniques. In this area, system resolution has been improved without loss of sensitivity by decreasing the air gap between patient and collimator surface. Since cerebral studies characteristically image high-contrast regions less than 1 cm in size, image quality has been improved by increasing collimator resolution even at the expense of sensitivity. Increased resolution also improved image contrast for studies using 123 I-labeled pharmaceuticals with 3% to 4% 124 I contamination. 65 references

  2. Paving the way to personalized medicine. Production of some theragnostic radionuclides at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Srivastava, S.C.

    2011-01-01

    This paper introduces a relatively novel paradigm that involves specific individual radionuclides or radionuclide pairs that have emissions that allow pre-therapy low-dose imaging plus higher-dose therapy in the same patient. We have made an attempt to sort out and organize a number of such theragnostic radionuclides and radionuclide pairs that may potentially bring us closer to the age-long dream of personalized medicine for performing tailored low-dose molecular imaging (SPECT/CT or PET/CT) to provide the necessary pre-therapy information on biodistribution, dosimetry, the limiting or critical organ or tissue, and the maximum tolerated dose (MTD), etc. If the imaging results then warrant it, it would be possible to perform higher-dose targeted molecular therapy in the same patient with the same radiopharmaceutical. A major problem that remains yet to be fully resolved is the lack of availability, in sufficient quantities, of a majority of the best candidate theragnostic radionuclides in a no-carrier-added (NCA) form. A brief description of the recently developed new or modified methods at BNL for the production of four theragnostic radionuclides, whose nuclear, physical, and chemical characteristics seem to show great promise for personalized cancer therapy are described.

  3. Relating β+ radionuclides' properties by order theory

    International Nuclear Information System (INIS)

    Quintero, N.Y.; Guillermo Restrepo; Cohen, I.M.; Universidad Tecnologica Nacional, Buenos Aires

    2013-01-01

    We studied 27 β + radionuclides taking into account some of their variants encoding information of their production, such as integral yield, threshold energy and energy of projectiles used to generate them; these radionuclides are of current use in clinical diagnostic imaging by positron emission tomography (PET). The study was conducted based on physical, physico-chemical, nuclear, dosimetric and quantum properties, which characterise the β + radionuclides selected, with the aim of finding meaningful relationships among them. In order to accomplish this objective the mathematical methodology known as formal concept analysis was employed. We obtained a set of logical assertions (rules) classified as implications and associations, for the set of β + radionuclides considered. Some of them show that low mass defect is related to high and medium values of maximum β + energy, and with even parity and low mean lives; all these parameters are associated to the dose received by a patient subjected to a PET analysis. (author)

  4. The evolution of radionuclide imaging

    International Nuclear Information System (INIS)

    Rollo, F.D.; Patton, J.A.; Cassen, B.

    1984-01-01

    This chapter briefly describes the evolution of scintillation imaging through the early 1980s. It is difficult, if not impossible, to evaluate the practical roles of current developments with any perspective, historical or otherwise. Waves of enthusiasm come and go. A simple analysis by Cassen of the factors entering into an overall performance index of any scanning or imaging system clearly shows that appreciable advances in instrumentation depend upon more efficient utilization of available gamma photons, and that future advances will depend upon the availability of agents having a greater photon yield and a smaller potential radiation dose. Further, the needs of the referring physician and improvements in other diagnostic modalities will have an impact on the future of nuclear medicine imaging requirements. For example, the availability of 201 T1 for myocardial imaging significantly increased the demand for spatial resolution of the scintillation camera. Likewise, the introduction of gated blood-pool imaging increased the requirements for count rate capabilities and spatial resolution. The need to evaluate the myocardium in the intensive care unit resulted in the development of the portable scintillation camera and computer. On the other hand, the introduction of CT for evaluating the brain had a significant impact on the value of nuclear medicine brain imaging. The impact of digital radiology and nuclear magnetic resonance can only be speculated at this point. If anything, they will probably serve as complements to nuclear medicine procedures in the diagnostic process, with nuclear medicine serving as the primary method of establishing functional information

  5. Use of phase images in radionuclide ventriculography for topical diagnosis of the Wolff-Parkinson-White syndrome and sources of abnormal rhythms in the ventricles

    International Nuclear Information System (INIS)

    Ostroumov, E.N.; Sergienko, V.B.; Golitsin, S.P.

    1990-01-01

    The paper presents the results of the mapping of various types of the Wolff-Parkinson-White syndrome and ventricular arrhythmias by using phase images of radionuclide ventriculograms as compared to 12 leads and electrophysiological studies. Phase images are a highly informative method that supplements an electrophysiological study in the topical diagnosis of abnormal tracts and ventricular arrhythmias

  6. Assessment of radionuclide databases in CAP88 mainframe version 1.0 and Windows-based version 3.0.

    Science.gov (United States)

    LaBone, Elizabeth D; Farfán, Eduardo B; Lee, Patricia L; Jannik, G Timothy; Donnelly, Elizabeth H; Foley, Trevor Q

    2009-09-01

    In this study the radionuclide databases for two versions of the Clean Air Act Assessment Package-1988 (CAP88) computer model were assessed in detail. CAP88 estimates radiation dose and the risk of health effects to human populations from radionuclide emissions to air. This program is used by several U.S. Department of Energy (DOE) facilities to comply with National Emission Standards for Hazardous Air Pollutants regulations. CAP88 Mainframe, referred to as version 1.0 on the U.S. Environmental Protection Agency Web site (http://www.epa.gov/radiation/assessment/CAP88/), was the very first CAP88 version released in 1988. Some DOE facilities including the Savannah River Site still employ this version (1.0) while others use the more user-friendly personal computer Windows-based version 3.0 released in December 2007. Version 1.0 uses the program RADRISK based on International Commission on Radiological Protection Publication 30 as its radionuclide database. Version 3.0 uses half-life, dose, and risk factor values based on Federal Guidance Report 13. Differences in these values could cause different results for the same input exposure data (same scenario), depending on which version of CAP88 is used. Consequently, the differences between the two versions are being assessed in detail at Savannah River National Laboratory. The version 1.0 and 3.0 database files contain 496 and 838 radionuclides, respectively, and though one would expect the newer version to include all the 496 radionuclides, 35 radionuclides are listed in version 1.0 that are not included in version 3.0. The majority of these has either extremely short or long half-lives or is no longer in production; however, some of the short-lived radionuclides might produce progeny of great interest at DOE sites. In addition, 122 radionuclides were found to have different half-lives in the two versions, with 21 over 3 percent different and 12 over 10 percent different.

  7. Image Sharing Technologies and Reduction of Imaging Utilization: A Systematic Review and Meta-analysis

    Science.gov (United States)

    Vest, Joshua R.; Jung, Hye-Young; Ostrovsky, Aaron; Das, Lala Tanmoy; McGinty, Geraldine B.

    2016-01-01

    Introduction Image sharing technologies may reduce unneeded imaging by improving provider access to imaging information. A systematic review and meta-analysis were conducted to summarize the impact of image sharing technologies on patient imaging utilization. Methods Quantitative evaluations of the effects of PACS, regional image exchange networks, interoperable electronic heath records, tools for importing physical media, and health information exchange systems on utilization were identified through a systematic review of the published and gray English-language literature (2004–2014). Outcomes, standard effect sizes (ESs), settings, technology, populations, and risk of bias were abstracted from each study. The impact of image sharing technologies was summarized with random-effects meta-analysis and meta-regression models. Results A total of 17 articles were included in the review, with a total of 42 different studies. Image sharing technology was associated with a significant decrease in repeat imaging (pooled effect size [ES] = −0.17; 95% confidence interval [CI] = [−0.25, −0.09]; P utilization (pooled ES = 0.20; 95% CI = [0.07, 0.32]; P = .002). For all outcomes combined, image sharing technology was not associated with utilization. Most studies were at risk for bias. Conclusions Image sharing technology was associated with reductions in repeat and unnecessary imaging, in both the overall literature and the most-rigorous studies. Stronger evidence is needed to further explore the role of specific technologies and their potential impact on various modalities, patient populations, and settings. PMID:26614882

  8. 100 Years of radionuclide metrology

    International Nuclear Information System (INIS)

    Judge, S.M.; Arnold, D.; Chauvenet, B.; Collé, R.; De Felice, P.; García-Toraño, E.; Wätjen, U.

    2014-01-01

    The discipline of radionuclide metrology at national standards institutes started in 1913 with the certification by Curie, Rutherford and Meyer of the first primary standards of radium. In early years, radium was a valuable commodity and the aim of the standards was largely to facilitate trade. The focus later changed to providing standards for the new wide range of radionuclides, so that radioactivity could be used for healthcare and industrial applications while minimising the risk to patients, workers and the environment. National measurement institutes responded to the changing demands by developing new techniques for realising primary standards of radioactivity. Looking ahead, there are likely to be demands for standards for new radionuclides used in nuclear medicine, an expansion of the scope of the field into quantitative imaging to facilitate accurate patient dosimetry for nuclear medicine, and an increasing need for accurate standards for radioactive waste management and nuclear forensics. - Highlights: • The driving forces for the development of radionuclide metrology. • Radium standards to facilitate trade of this valuable commodity in the early years. • After 1950, focus changes to healthcare and industrial applications. • National Measurement Institutes develop new techniques, standards, and disseminate the best practice in measurement. • Challenges in nuclear medicine, radioactive waste management and nuclear forensics

  9. New design targets and new automated technology for the production of radionuclides with high specificity radioactivity in nuclear research reactors

    International Nuclear Information System (INIS)

    Gerasimov, A.S.; Kiselev, G.V.

    1997-01-01

    Current demands of industry require the application of radionuclides with high specific radioactivity under low consumption of neutrons. To provide this aim staff of ITEP Reactor Department investigated the different type AEs of start targets for the production of the main radionuclides; Co-60, Ir-192 and others. In first turn the targets of Co and Ir without the block-effect of neutron flux (with low absorption of neutrons) were investigated. The following principal results were received for example for Ir-192: block effect is equal 0.086 for diameter of Ir target mm and is equal 0.615 for diameter Ir target 0.5mm. It means average neutron flux for Ir target diameter 0.5mm and therefore the production of Ir-192 will be at 10 times more than for diameter 6.0mm. To provide the automated technology of the manufacture of radioactive sources with radionuclides with high specific radioactivity it was proposed that the compound targets for the irradiation of ones and for the management with the irradiated targets. Different types of compound targets were analyzed. (authors)

  10. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  11. Critical review: Radionuclide transport, sediment transport, and water quality mathematical modeling; and radionuclide adsorption/desorption mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Y.; Serne, R.J.; Arnold, E.M.; Cowan, C.E.; Thompson, F.L. [Pacific Northwest Lab., Richland, WA (United States)

    1981-01-01

    This report describes the results of a detailed literature review of radionuclide transport models applicable to rivers, estuaries, coastal waters, the Great Lakes, and impoundments. Some representatives sediment transport and water quality models were also reviewed to evaluate if they can be readily adapted to radionuclide transport modeling. The review showed that most available transport models were developed for dissolved radionuclide in rivers. These models include the mechanisms of advection, dispersion, and radionuclide decay. Since the models do not include sediment and radionuclide interactions, they are best suited for simulating short-term radionuclide migration where: (1) radionuclides have small distribution coefficients; (2) sediment concentrations in receiving water bodies are very low. Only 5 of the reviewed models include full sediment and radionuclide interactions: CHMSED developed by Fields; FETRA SERATRA, and TODAM developed by Onishi et al, and a model developed by Shull and Gloyna. The 5 models are applicable to cases where: (1) the distribution coefficient is large; (2) sediment concentrations are high; or (3) long-term migration and accumulation are under consideration. The report also discusses radionuclide absorption/desorption distribution ratios and addresses adsorption/desorption mechanisms and their controlling processes for 25 elements under surface water conditions. These elements are: Am, Sb, C, Ce, Cm, Co, Cr, Cs, Eu, I, Fe, Mn, Np, P, Pu, Pm, Ra, Ru, Sr, Tc, Th, {sup 3}H, U, Zn and Zr.

  12. Evaluation of energy spectral information in nuclear imaging and investigation of protein binding of cationic radionuclides by lactoferrin. Comprehensive progress report, October 1, 1977-September 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, P. B.

    1980-06-10

    Construction of an Anger camera-computer system which allows collection of both the position and energy signals from events detected by the scintillation camera has been completed. The system allows correction of energy response non-uniformity of the detector and facilitates research related to effects of energy discrimination in radionuclide scintigraphy. The system consists of electronic hardware to transmit and digitize the energy signal, software to record and process that signal in conjunction with spatial positioning signals, and additional hardware for recording the processed images so that they can be evaluated by observers. Preliminary results indicate that the system is useful in evaluating clinical images. Assymetric (eccentric) energy windows do improve image quality and are of value in improving detection of lesions on liver scintigraphs. The mechanisms by which Ga-67 is taken up in infection and tumor has been elucidated, and the uptake of radiogallium in microorganisms as a function of its interaction with siderophores was also studied. The primary function of these low molecular weight compounds is to trap ferric ion. However, gallium may be substituted for ferric ion and becomes trapped within the microorganism. The uptake of radiogallium by neutrophils and the role that lactoferrin plays in both intracellular localization of radiogallium and subsequent deposition of the radionuclide at sites of infection were also studied. Investigation of ferric ion analogs reveals definate differences in the affinity of these metals for binding molecules which helps explain their biologic activity. While ferric ion has the strongest affinity for such molecules, gallium has very high affinity for siderophores, moderate affinity for lactoferrin, and lower affinity for transferrin. The relative affinity of indium for these molecules is in approximately the reverse order.

  13. Radionuclide data

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Chapter 8 presents tables on selected alpha, beta, gamma and x-ray emitters by increasing energy; information on specific activity for selected radionuclides; naturally occurring radionuclides; the natural decay series; and the artificially produced neptunium series. A table of alpha emitters is listed by increasing atomic number and by energy. The table of β emitters presented is useful in identifying β emitters whose energies and possibly half-lives have been determined by standard laboratory techniques. It is also a handy guide to β-emitting isotopes for applications requiring specific half-lives and/or energies. Gamma rays for radionuclides of importance to radiological assessments and radiation protection are listed by increasing energy. The energies and branching ratios are important for radionuclide determinations with gamma spectrometry detectors. This section also presents a table of x-ray energies which are useful for radiochemical analyses. A number of nuclides emit x-rays as part of their decay scheme. These x-rays may be counted with Ar proportional counters, Ge planar or n-type Ge co-axial detectors, or thin crystal NaI(T1) scintillation counters. In both cases, spectral measurements can be made and both qualitative and quantitative information obtained on the sample. Nuclear decay data (energy and probability by radiation type) for more than one hundred radionuclides that are important to health physicists are presented in a schematic manner

  14. Biomedical Optical Imaging Technologies Design and Applications

    CERN Document Server

    2013-01-01

    This book provides an introduction to design of biomedical optical imaging technologies and their applications. The main topics include: fluorescence imaging, confocal imaging, micro-endoscope, polarization imaging, hyperspectral imaging, OCT imaging, multimodal imaging and spectroscopic systems. Each chapter is written by the world leaders of the respective fields, and will cover: principles and limitations of optical imaging technology, system design and practical implementation for one or two specific applications, including design guidelines, system configuration, optical design, component requirements and selection, system optimization and design examples, recent advances and applications in biomedical researches and clinical imaging. This book serves as a reference for students and researchers in optics and biomedical engineering.

  15. DOTA-PESIN, a DOTA-conjugated bombesin derivative designed for the imaging and targeted radionuclide treatment of bombesin receptor-positive tumours

    International Nuclear Information System (INIS)

    Zhang, Hanwen; Maecke, Helmut R.; Schuhmacher, Jochen; Eisenhut, Michael; Waser, Beatrice; Reubi, Jean Claude; Wild, Damian

    2007-01-01

    We aimed at designing and developing a novel bombesin analogue, DOTA-PEG 4 -BN(7-14) (DOTA-PESIN), with the goal of labelling it with 67/68 Ga and 177 Lu for diagnosis and radionuclide therapy of prostate and other human cancers overexpressing bombesin receptors. The 8-amino acid peptide bombesin (7-14) was coupled to the macrocyclic chelator DOTA via the spacer 15-amino-4,7,10,13-tetraoxapentadecanoic acid (PEG 4 ). The conjugate was complexed with Ga(III) and Lu(III) salts. The GRP receptor affinity and the bombesin receptor subtype profile were determined in human tumour specimens expressing the three bombesin receptor subtypes. Internalisation and efflux studies were performed with the human GRP receptor cell line PC-3. Xenografted nude mice were used for biodistribution. [Ga III /Lu III ]-DOTA-PESIN showed good affinity to GRP and neuromedin B receptors but no affinity to BB3. [ 67 Ga/ 177 Lu]-DOTA-PESIN internalised rapidly into PC-3 cells whereas the efflux from PC-3 cells was relatively slow. In vivo experiments showed a high and specific tumour uptake and good retention of [ 67 Ga/ 177 Lu]-DOTA-PESIN. [ 67 Ga/ 177 Lu]-DOTA-PESIN highly accumulated in GRP receptor-expressing mouse pancreas. The uptake specificity was demonstrated by blocking tumour uptake and pancreas uptake. Fast clearance was found from blood and all non-target organs except the kidneys. High tumour-to-normal tissue ratios were achieved, which increased with time. PET imaging with [ 68 Ga]-DOTA-PESIN was successful in visualising the tumour at 1 h post injection. Planar scintigraphic imaging showed that the 177 Lu-labelled peptide remained in the tumour even 3 days post injection. The newly designed ligands have high potential with regard to PET and SPECT imaging with 68/67 Ga and targeted radionuclide therapy with 177 Lu. (orig.)

  16. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de [University of Amsterdam, Department of Nuclear Medicine, F2-238, Academic Medical Center, Amsterdam (Netherlands); Acampa, Wanda [National Council of Research, Institute of Biostructures and Bioimaging, Naples (Italy); Anagnostopoulos, Constantinos [Academy of Athens, Center for Experimental Surgery, Clinical and Translational Research, Biomedical Research Foundation, Athens (Greece); Ballinger, Jim [Guy' s Hospital - Guy' s and St Thomas' Trust Foundation, Department of Nuclear Medicine, London (United Kingdom); Bengel, Frank [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Bondt, Pieter De [OLV Hospital, Department of Nuclear Medicine, Aalst (Belgium); Buechel, Ronny R.; Kaufmann, Philip A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Flotats, Albert [Universitat Autonoma de Barcelona, Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Hindorf, Cecilia [Skaane University Hospital, Department of Radiation Physics, Lund (Sweden); Lindner, Oliver [University Hospital of the Ruhr-University Bochum, Heart and Diabetes Center North Rhine-Westphalia, Institute for Radiology, Nuclear Medicine and Molecular Imaging, Bad Oeynhausen (Germany); Ljungberg, Michael [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Lonsdale, Markus [Bispebjerg Hospital, Department of Clinical Physiology and Nuclear Medicine, Copenhagen (Denmark); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Service Commun Investigations chez l' Homme, GIP Cyceron, Caen (France); Minarik, David [Skaane University Hospital, Radiation Physics, Malmoe (Sweden); Scholte, Arthur J.H.A. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Traegaardh, Elin [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Malmoe (Sweden); Hesse, Birger [University Hospital of Copenhagen, Department of Clinical Physiology and Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015{sub 0}7{sub E}ANM{sub F}INAL myocardial{sub p}erfusion{sub g}uideline.pdf. (orig.)

  17. Directory of cyclotrons used for radionuclide production in Member States [2006 update

    International Nuclear Information System (INIS)

    2006-10-01

    The present directory of cyclotron facilities used for the production of radionuclides in Member States is an update of the one compiled by the International Atomic Energy Agency (IAEA) in late 2001 and published in 2002. This directory was prepared through information collected by questionnaires that the IAEA sent to known institutions operating cyclotrons for radionuclide production. Technical as well as administrative data supplied to the IAEA as of November 2005 were taken into account. The directory is considered to include most of the cyclotrons of the world that are used at least partially for radionuclide production. There are 262 entries for cyclotrons operating in 39 Member States of the IAEA. This is an increase of 7% over the 246 reported in the 2002 cyclotron directory. This can be compared to the 350 or so cyclotrons believed to be presently operating in the world, which are involved in some aspects of radionuclide production. The increase has been in the number of cyclotrons in developed countries, but even more so in the developing countries. The increase in number during the last four years was driven by several factors, i.e. advent of advances in medical imaging, introduction of compact, user friendly medical cyclotron, and a recent decision that costs for 15 O-oxygen position emission tomography (PET) studies in Japan and 18 F-FDG PET studies in Germany and the United States of America are eligible for reimbursement by government or health insurance companies. There is no doubt that the fastest growing segment of the market is in the commercial distribution of FDG to local hospitals. The IAEA is promoting cyclotron technology as applied to nuclear medicine. Requests for cyclotron technology is steadily increasing; many developing Member States are interested in this technology. There is need to stimulate, build and maintain consulting capability in interested developing Member States. There are good reasons to believe that the number of cyclotron

  18. Radionuclide carrier

    International Nuclear Information System (INIS)

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  19. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  20. Radionuclide production and radiopharmaceutical chemistry with BNL cyclotrons

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wolf, A.P.

    1985-01-01

    The Brookhaven National Laboratory (BNL) radiopharmaceutical chemistry program focuses on production and utilization of radionuclides having a half-life of > 2 hr. However, a major portion of the BNL program is devoted to short-lived radionuclides, such as 11 C and 18 F. Activities encompassed in the program are classified into seven areas: cyclotron parameters, radiochemistry, design and rapid synthesis of radiopharmaceuticals and labeled compounds, radiotracer evaluation in animals, studies in humans, technology transfer, and several other areas

  1. Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis

    Science.gov (United States)

    Nan, Song

    2018-03-01

    Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.

  2. Technologies for destruction of long-lived radionuclides in high-level nuclear waste - overview and requirements

    International Nuclear Information System (INIS)

    Arthur, E.D.

    1993-01-01

    A major issue surrounding current nuclear power generation is the management and disposal of long-lived, high-level waste (HLW). The planned and scientifically acceptable destination for this waste is in deep underground, geologically stable, repositories. However, public concerns surrounding such disposal of long-lived nuclear wastes and other issues such as proliferation and safety negatively affect the potential role that nuclear power can play in meeting current and future national energy needs. This paper and this topical session on nuclear waste minimization, management, and remediation focus on two nuclear systems and their associated technologies that have the potential to address concerns surrounding long-lived radionuclides in HLW. Both systems offer technology applicable to HLW from current light water reactors (LWRs). In addition, these systems represent advanced nuclear power concepts that have important features associated with integrated management of wastes long-term fuel supplies, and enhanced safety. The first system is the integral fast reactor (IFR) concept. This system incorporates a metal-fueled fast reactor coupled with chemical separations based on pyroprocessing to produce power while burning long-lived actinide waste. The IFR applications include the burning of actinides from current LWR spent fuel and energy production in a breeder environment. The second concept, accelerator transmutation of waste (ATW), is based on an accelerator-induced intense source of thermal neutrons and is aimed at the destruction of long-lived actinides and fission products. This concept can be applied to long-lived radionuclides in spent-fuel HLW as well as a future fission power source built around use of natural thorium or uranium as fuels coupled with concurrent waste destruction

  3. Radionuclide angiography and blood pool imaging to assess skin ulcer healing prognosis in patients with peripheral vascular disease

    International Nuclear Information System (INIS)

    Alazraki, N.; Lawrence, P.F.; Syverud, J.B.

    1984-01-01

    Several non-invasive diagnostic techniques including segmental limb blood pressures, skin fluoresence, and photo plethysmography, have been evaluated as predictors of skin ulcer healing in patients with peripheral vascular disease, but none are widely used. Using 20mCi of Tc-99m phosphate compounds, four phase bone scans were obtained, including (1) radionuclide angiogram (2) blood pool image (3) 2 hour and 4-6 hour static images and (4) 24 hour static delayed images. The first two phases were used to assess vacularity to the region of distal extremity ulceration; the last two phases evaluated presence or absence of osteomyelitis. Studies were performed in 30 patients with non-healing ulcers of the lower extremities. Perfusion to the regions of ulceration on images was graded as normal, increased, or reduced with respect to the opposite (presumed normal) limb or some other normal reference area. Hypervascular response was interpreted as good prognosis for healing unless osteomyelitis was present. Clinicians followed patients for 14 days to assess limb healing with optimum care. If there was no improvement, angiography and/or surgery (reconstructive surgery, sympathectomy, or amputation) was done. Results showed: sensitivity for predicting ulcer healing was 94%, specificity 89%. Patients who failed to heal their ulcers showed reduced perfusion, no hypervascular response, or osteomyelitis. Microcirculatory adequacy for ulcer healing appear predictable by this technique

  4. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.; Pennsylvania, University, Philadelphia, PA)

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique

  5. Application of stereo-imaging technology to medical field.

    Science.gov (United States)

    Nam, Kyoung Won; Park, Jeongyun; Kim, In Young; Kim, Kwang Gi

    2012-09-01

    There has been continuous development in the area of stereoscopic medical imaging devices, and many stereoscopic imaging devices have been realized and applied in the medical field. In this article, we review past and current trends pertaining to the application stereo-imaging technologies in the medical field. We describe the basic principles of stereo vision and visual issues related to it, including visual discomfort, binocular disparities, vergence-accommodation mismatch, and visual fatigue. We also present a brief history of medical applications of stereo-imaging techniques, examples of recently developed stereoscopic medical devices, and patent application trends as they pertain to stereo-imaging medical devices. Three-dimensional (3D) stereo-imaging technology can provide more realistic depth perception to the viewer than conventional two-dimensional imaging technology. Therefore, it allows for a more accurate understanding and analysis of the morphology of an object. Based on these advantages, the significance of stereoscopic imaging in the medical field increases in accordance with the increase in the number of laparoscopic surgeries, and stereo-imaging technology plays a key role in the diagnoses of the detailed morphologies of small biological specimens. The application of 3D stereo-imaging technology to the medical field will help improve surgical accuracy, reduce operation times, and enhance patient safety. Therefore, it is important to develop more enhanced stereoscopic medical devices.

  6. Selection of dominant radionuclides for Phase 1 of the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.

    1991-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at Hanford since their inception in 1944. A vital step in the estimation of radiation doses is the determination of the source term,'' that is, the quantities of radionuclides that were released to the environment from the various Hanford operations. Hanford operations have at various times involved hundreds of different radionuclides, some in relatively large quantities. Those radionuclides present in the largest quantities, although significant from an operational handling point of view, may not necessarily have been those of greatest concern for offsite radiation dose. This report documents the selection of the dominant radionuclides (those that may have resulted in the largest portion of the received doses) in the source term for Phase 1 of the HEDR Project, that is, for atmospheric releases from 1944 through 1947 and for surface water releases from 1964 through 1966. 15 refs., 3 figs., 10 tabs.

  7. Methods of separating short half-life radionuclides from a mixture of radionuclides

    International Nuclear Information System (INIS)

    Bray, L.A.; Ryan, J.L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of 223 Ra and 225 Ac, from a radionuclide ''cow'' of 227 Ac or 229 Th respectively. The method comprises the steps of (a) permitting ingrowth of at least one radionuclide daughter from said radionuclide ''cow'' forming an ingrown mixture; (b) insuring that the ingrown mixture is a nitric acid ingrown mixture; (c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the ''cow'' from at least one radionuclide daughter; (d) insuring that the at least one radionuclide daughter contains the radionuclide product; (e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and (f) recycling the at least one radionuclide daughter by adding it to the ''cow''. In one embodiment the radionuclide ''cow'' is the 227 Ac, the at least one daughter radionuclide is a 227 Th and the product radionuclide is the 223 Ra and the first nitrate form ion exchange column passes the 227 Ac and retains the 227 Th. In another embodiment the radionuclide ''cow'' is the 229 Th, the at least one daughter radionuclide is a 225 Ra and said product radionuclide is the 225 Ac and the 225 Ac and nitrate form ion exchange column retains the 229 Th and passes the 225 Ra/Ac. 8 figs

  8. Conditions and processes affecting radionuclide transport

    Science.gov (United States)

    Simmons, Ardyth M.; Neymark, Leonid A.

    2012-01-01

    Characteristics of host rocks, secondary minerals, and fluids would affect the transport of radionuclides from a previously proposed repository at Yucca Mountain, Nevada. Minerals in the Yucca Mountain tuffs that are important for retarding radionuclides include clinoptilolite and mordenite (zeolites), clay minerals, and iron and manganese oxides and hydroxides. Water compositions along flow paths beneath Yucca Mountain are controlled by dissolution reactions, silica and calcite precipitation, and ion-exchange reactions. Radionuclide concentrations along flow paths from a repository could be limited by (1) low waste-form dissolution rates, (2) low radionuclide solubility, and (3) radionuclide sorption onto geological media.

  9. New imaging systems in nuclear medicine. Technical progress report, July 1, 1974--April 1, 1975

    International Nuclear Information System (INIS)

    Brownell, G.L.

    1975-01-01

    Design modifications in a positron camera that improve imaging in diagnostic studies using short-lived cyclotron-produced radionuclides as tracers are described. Results are reported from clinical studies using 13 N for inhalation studies; 15 O to measure pulmonary ventilation, perfusion, and regional lung water; and the use of 13 N-ammonia, 68 Ga-microspheres, and 82 Rb for cardiac imaging and studies of blood flow in the brain. (U.S.)

  10. Cyclotron Production of Radionuclides for Nuclear Medicine at Academic Centers

    Science.gov (United States)

    Lapi, Suzanne

    2016-09-01

    The increase in use of radioisotopes for medical imaging has led to the development of new accelerator targetry and separation techniques for isotope production. For example, the development of longer-lived position emitting radionuclides has been explored to allow for nuclear imaging agents based on peptides, antibodies and nanoparticles. These isotopes (64Cu, 89Zr, 86Y) are typically produced via irradiation of solid targets on smaller cyclotrons (10-25 MeV) at academic or hospital based facilities. Recent research has further expanded the toolbox of PET tracers to include additional isotopes such as 52Mn, 55Co, 76Br and others. The smaller scale of these types of facilities can enable the straightforward involvement of students, thus adding to the next generation of nuclear science leaders. Research pertaining to development of robust and larger scale production technologies including solid target systems and remote systems for transport and purification of these isotopes has enabled both preclinical and clinical imaging research for many diseases. In particular, our group has focused on the use of radiolabeled antibodies for imaging of receptor expression in preclinical models and in a clinical trial of metastatic breast cancer patients.

  11. Methods of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, Lane A.; Ryan, Jack L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of .sup.223 Ra and .sup.225 Ac, from a radionuclide "cow" of .sup.227 Ac or .sup.229 Th respectively. The method comprises the steps of a) permitting ingrowth of at least one radionuclide daughter from said radionuclide "cow" forming an ingrown mixture; b) insuring that the ingrown mixture is a nitric acid ingrown mixture; c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the "cow" from at least one radionuclide daughter; d) insuring that the at least one radionuclide daughter contains the radionuclide product; e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and f) recycling the at least one radionuclide daughter by adding it to the "cow". In one embodiment the radionuclide "cow" is the .sup.227 Ac, the at least one daughter radionuclide is a .sup.227 Th and the product radionuclide is the .sup.223 Ra and the first nitrate form ion exchange column passes the .sup.227 Ac and retains the .sup.227 Th. In another embodiment the radionuclide "cow"is the .sup.229 Th, the at least one daughter radionuclide is a .sup.225 Ra and said product radionuclide is the .sup.225 Ac and the .sup.225 Ac and nitrate form ion exchange column retains the .sup.229 Th and passes the .sup.225 Ra/Ac.

  12. Identification of Ambiguous Activities in Radionuclide Cisternography Using SPECT/CT: Aspirated and Ingested CSF Rhinorrhea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yun; Kim, Jae Seung [Univ. of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2014-03-15

    A 2 year-old little girl underwent Tc-99m diethylenthriamine pentaacetic acid (DTPA) radionuclide cisternography to evaluate CSF rhinorrhea (Fig. 1). Cisternography clearly showed consecutive tracer activity in the nasal cavity and nasal tip, reflecting cerebrospinal fluid (CSF) leakage. However, several unexpected activities appeared on the bilateral mid- and unilateral lower thorax on delayed images, respectively. We performed additional SPECT/CT to delineate the CSF leakage tract and identify the unexpected activities. Through SPECT/CT, we could confirm that the mid-thoracic activity was in the lung parenchyma, while the lower thoracic activity was in the stomach. Thus, we speculated that these unexpected activities were the result of aspirated and ingested CSF rhinorrhea. CSF rhinorrhea occurs when there is a fistula between the dura mater and the skull base and discharge of CSF from the nose. A spinal fluid leak from the intracranial space to the nasal respiratory tract is potentially very serious because of the risk of an ascending infection that could produce fulminant meningitis. Therefore, identification of the fistulous tract is helpful for patient management. Radionuclide cisternography is an important imaging modality to detect the site of leakage in patients with CSF rhinorrhea. The combination of radionuclide cistenography and SPECT/CT has led to a major improvement in the diagnostic accuracy for localization of CSF leakage. This case also shows an important role for SPECT/CT fusion imaging in radionuclide cisternography not only for localizing the primary CSF fistula tract, but also for evaluating ambiguous radiotracer activities in planar imaging; these ultimately turned out to be aspirated and ingested CSF rhinorrhea.

  13. Identification of Ambiguous Activities in Radionuclide Cisternography Using SPECT/CT: Aspirated and Ingested CSF Rhinorrhea

    International Nuclear Information System (INIS)

    Lee, Dong Yun; Kim, Jae Seung

    2014-01-01

    A 2 year-old little girl underwent Tc-99m diethylenthriamine pentaacetic acid (DTPA) radionuclide cisternography to evaluate CSF rhinorrhea (Fig. 1). Cisternography clearly showed consecutive tracer activity in the nasal cavity and nasal tip, reflecting cerebrospinal fluid (CSF) leakage. However, several unexpected activities appeared on the bilateral mid- and unilateral lower thorax on delayed images, respectively. We performed additional SPECT/CT to delineate the CSF leakage tract and identify the unexpected activities. Through SPECT/CT, we could confirm that the mid-thoracic activity was in the lung parenchyma, while the lower thoracic activity was in the stomach. Thus, we speculated that these unexpected activities were the result of aspirated and ingested CSF rhinorrhea. CSF rhinorrhea occurs when there is a fistula between the dura mater and the skull base and discharge of CSF from the nose. A spinal fluid leak from the intracranial space to the nasal respiratory tract is potentially very serious because of the risk of an ascending infection that could produce fulminant meningitis. Therefore, identification of the fistulous tract is helpful for patient management. Radionuclide cisternography is an important imaging modality to detect the site of leakage in patients with CSF rhinorrhea. The combination of radionuclide cistenography and SPECT/CT has led to a major improvement in the diagnostic accuracy for localization of CSF leakage. This case also shows an important role for SPECT/CT fusion imaging in radionuclide cisternography not only for localizing the primary CSF fistula tract, but also for evaluating ambiguous radiotracer activities in planar imaging; these ultimately turned out to be aspirated and ingested CSF rhinorrhea

  14. Anthropogenic radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Weng, J; Wang, J

    2007-11-15

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview of anthropogenic radionuclide contamination in the environment, as well as the salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current development that contribute to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) commercial fuel reprocessing; (5) geological repository of high-level nuclear wastes, and (6) nuclear accidents. Then, we summarize the geochemical behavior for radionuclides {sup 99}Tc, {sup 129}I, and {sup 237}Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment. Biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  15. Radioactivity measurements using storage phosphor technology

    International Nuclear Information System (INIS)

    Cheng, Y.T.; Hwang, J.; Hutchinson, M.R.

    1995-01-01

    We propose to apply a recently developed charged particle radiation imaging concept in bio-medical research for fast, cost-effective characterization of radionuclides in contaminated sites and environmental samples. This concept utilizes sensors with storage photostimulable phosphor (SPP) technology as radiation detectors. They exhibit high sensitivity for all types of radiation and the response is linear over a wide dynamic range (>10 5 ), essential for quantitative analysis. These new sensors have an active area of up to 35 cm x 43 cm in size and a spatial resolution as fine as 50 μm. They offer considerable promise as large area detectors for fast characterization of radionuclides with an added ability to locate and identify hot spots

  16. Optimal energy window setting depending on the energy resolution for radionuclides used in gamma camera imaging. Planar imaging evaluation

    International Nuclear Information System (INIS)

    Kojima, Akihiro; Watanabe, Hiroyuki; Arao, Yuichi; Kawasaki, Masaaki; Takaki, Akihiro; Matsumoto, Masanori

    2007-01-01

    In this study, we examined whether the optimal energy window (EW) setting depending on an energy resolution of a gamma camera, which we previously proposed, is valid on planar scintigraphic imaging using Tl-201, Ga-67, Tc-99m, and I-123. Image acquisitions for line sources and paper sheet phantoms containing each radionuclide were performed in air and with scattering materials. For the six photopeaks excluding the Hg-201 characteristic x-rays' one, the conventional 20%-width energy window (EW20%) setting and the optimal energy window (optimal EW) setting (15%-width below 100 keV and 13%-width above 100 keV) were compared. For the Hg-201 characteristic x-rays' photopeak, the conventional on-peak EW20% setting was compared with the off-peak EW setting (73 keV-25%) and the wider off-peak EW setting (77 keV-29%). Image-count ratio (defined as the ratio of the image counts obtained with an EW and the total image counts obtained with the EW covered the whole photopeak for a line source in air), image quality, spatial resolutions (full width half maximum (FWHM) and full width tenth maximum (FWTM) values), count-profile curves, and defect-contrast values were compared between the conventional EW setting and the optimal EW setting. Except for the Hg-201 characteristic x-rays, the image-count ratios were 94-99% for the EW20% setting, but 78-89% for the optimal EW setting. However, the optimal EW setting reduced scatter fraction (defined as the scattered-to-primary counts ratio) effectively, as compared with the EW20% setting. Consequently, all the images with the optimal EW setting gave better image quality than ones with the EW20% setting. For the Hg-201 characteristic x-rays, the off-peak EW setting showed great improvement in image quality in comparison with the EW20% setting and the wider off-peak EW setting gave the best results. In conclusion, from our planar imaging study it was shown that although the optimal EW setting proposed by us gives less image-count ratio by

  17. Research on the assessment technology of the radionuclide inventory for the radioactive waste disposal(I)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. J.; Hong, D. S.; Hwang, G. H.; Shin, J. J.; Yuk, D. S. [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2002-03-15

    Characteristics and states of management of low and intermediate level radioactive waste in site : state of management for each type of wastes, characteristics of low and intermediate level solid radioactive waste, stage of management of low and intermediate level solid radioactive waste. Survey of state of management and characteristics of low and intermediate level radioactive waste disposal facility in foreign countries : state of management of disposal facilities, classification criteria and target radionuclides for assessment in foreign disposal facilities. Survey of the assessment methods of the radionuclides inventory and establishing the direction of requirement : assessment methods of the radionuclides inventory, analysis of radionuclides assay system in KORI site, establishment the direction of requirement in the assessment methods.

  18. Consultative committee on ionizing radiation: Impact on radionuclide metrology

    International Nuclear Information System (INIS)

    Karam, L.R.; Ratel, G.

    2016-01-01

    In response to the CIPM MRA, and to improve radioactivity measurements in the face of advancing technologies, the CIPM's consultative committee on ionizing radiation developed a strategic approach to the realization and validation of measurement traceability for radionuclide metrology. As a consequence, measurement institutions throughout the world have devoted no small effort to establish radionuclide metrology capabilities, supported by active quality management systems and validated through prioritized participation in international comparisons, providing a varied stakeholder community with measurement confidence. - Highlights: • Influence of CIPM MRA on radionuclide metrology at laboratories around the world. • CCRI strategy: to be the “undisputed hub for ionizing radiation global metrology.” • CCRI Strategic Plan stresses importance of measurement confidence for stakeholder. • NMIs increasing role in radionuclide metrology by designating institutions (DIs). • NMIs and DIs establish quality systems; validate capabilities through comparisons.

  19. Trends in cyclotrons for radionuclide production

    International Nuclear Information System (INIS)

    Vera Ruiz, H.; Lambrecht, R.M.

    1999-01-01

    The IAEA recently concluded a worldwide survey of the cyclotrons used for radionuclide production. Most of the institutions responded to the questionnaire. The responses identified technical, utilisation and administrative information for 206 cyclotrons. Compiled data includes the characteristics, performance and popularity of each of the different commercial cyclotrons. Over 20 cyclotrons are scheduled for installation in 1998. The expansion in the number of cyclotron installations during the last decade was driven by the advent of advances in medical imaging instrumentation (namely, positron emission tomography (PET), and more recently by 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons; and recent governmental decisions that permit reimbursement for cyclotron radiopharmaceutical studies by the government or insurance companies. The priorities for the production of clinical, commercial and research radionuclides were identified. The emphasis is on radionuclides used for medical diagnosis with SPET (e.g. 123 I, 201 Tl) and PET (e.g. 11 C, 13 N, 15 O, 18 F) radiopharmaceuticals, and for individualized patient radiation treatment planning (e.g. 64 Cu, 86 Y, 124 I) with PET. There is an emerging trend to advance the cyclotron as an alternative method to nuclear reactors for the production of neutron-rich radionuclides (e.g. 64 Cu, 103 Pd, 186 Re) needed for therapeutic applications. (authors)

  20. Natural radionuclides in the UK marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Rollo, S F.N.; Camplin, W C; Allington, D J; Young, A K [Ministry of Agriculture, Fisheries and Food, Lowestoft (United Kingdom). Fisheries Radiobiological Lab.

    1992-01-01

    The importance of natural radionuclides giving rise to radiation exposure of man from marine consumption pathways has been known for some time. However, the extent of surveys of levels in marine biota has been limited. This paper presents new data on concentrations of natural radionuclides in fish, shellfish and seaweeds taken from coastal sampling locations in the U.K. Sampling included areas where levels due to natural sources would be predominant, but efforts were made to study potential sources of technologically enhanced discharges to seas and rivers, particularly the phosphogypsum plant at Whitehaven in Cumbria. The highest concentrations (up to 371 Bq.kg[sup -1] (wet) [sup 210]Po) were observed in winkles near Whitehaven. The general levels at sites remote from known sources were much lower. Monthly concentrations in molluscs at a single location were elevated by approximately a factor of 2 during the summer months. An assessment of the expected doses to members of the public from marine consumption pathways is made. (author).

  1. Production of selected cosmogenic radionuclides by muons; 1, Fast muons

    CERN Document Server

    Heisinger, B; Jull, A J T; Kubik, P W; Ivy-Ochs, S; Neumaier, S; Knie, K; Lazarev, V A; Nolte, E

    2002-01-01

    To investigate muon-induced nuclear reactions leading to the production of radionuclides, targets made of C/sub 9/H/sub 12/, SiO /sub 2/, Al/sub 2/O/sub 3/, Al, S, CaCO/sub 3/, Fe, Ni, Cu, Gd, Yb and Tl were irradiated with 100 and 190 GeV muons in the NA54 experimental setup at CERN. The radionuclide concentrations were measured with accelerator mass spectrometry and gamma -spectroscopy. Results are presented for the corresponding partial formation cross- sections. Several of the long-lived and short-lived radionuclides studied are also produced by fast cosmic ray muons in the atmosphere and at depths underground. Because of their importance to Earth sciences investigations, calculations of the depth dependence of production rates by fast cosmic ray muons have been made. (48 refs).

  2. A new approach to nuclear fuel safeguard enhancement through radionuclide profiling

    Science.gov (United States)

    Peterson, Aaron Dawon

    The United States has led the effort to promote peaceful use of nuclear power amongst states actively utilizing it as well as those looking to deploy the technology in the near future. With the attraction being demonstrated by various countries towards nuclear power comes the concern that a nation may have military aspirations for the use of nuclear energy. The International Atomic Energy Agency (IAEA) has established nuclear safeguard protocols and procedures to mitigate nuclear proliferation. The work herein proposed a strategy to further enhance existing safeguard protocols by considering safeguard in nuclear fuel design. The strategy involved the use of radionuclides to profile nuclear fuels. Six radionuclides were selected as identifier materials. The decay and transmutation of these radionuclides were analyzed in reactor operation environment. MCNPX was used to simulate a reactor core. The perturbation in reactivity of the core due to the loading of the radionuclides was insignificant. The maximum positive and negative reactivity change induced was at day 1900 with a value of 0.00185 +/- 0.00256 and at day 2000 with -0.00441 +/- 0.00249, respectively. The mass of the radionuclides were practically unaffected by transmutation in the core; the change in radionuclide inventory was dominated by natural decay. The maximum material lost due to transmutation was 1.17% in Eu154. Extraneous signals from fission products identical to the radionuclide compromised the identifier signals. Eu154 saw a maximum intensity change at EOC and 30 days post-irradiation of 1260% and 4545%, respectively. Cs137 saw a minimum change of 12% and 89%, respectively. Mitigation of the extraneous signals is cardinal to the success of the proposed strategy. The predictability of natural decay provides a basis for the characterization of the signals from the radionuclide.

  3. Radionuclide trap

    International Nuclear Information System (INIS)

    McGuire, J.C.

    1978-01-01

    The deposition of radionuclides manganese-54, cobalt-58 and cobalt-60 from liquid sodium coolant is controlled by providing surfaces of nickel or high nickel alloys to extract the radionuclides from the liquid sodium, and by providing surfaces of tungsten, molybdenum or tantalum to prevent or retard radionuclide deposition

  4. Training in radionuclide methodology and applications in biomedical area

    International Nuclear Information System (INIS)

    Signoretta, C.

    1998-01-01

    Full text: Training in the field of radionuclide methodology and applications in biomedical area is important to assure that radionuclide should duly be used without risk for patients or for technicians manipulating them. The National Atomic Energy Commission (CNEA) from its creation is giving training courses of different technical levels to those working in science and technology. The Course on Radionuclide Methodology and application is the most continuous, varied and requested within CNEA. This is a basic course mainly given to Biochemistry and Medicine. Its goal is to give both theoretical and practical knowledge for use and application of radionuclides bearing in mind radiological safety regulations. Personnel from CNEA and Nuclear Regulatory Authority (ARN) carry out teaching. On the other hand, a course for Technicians in Nuclear Medicine is giving supplying knowledge in this field, as well as expertise and practice to attend a responsible Medical Doctor. These curses comprise radionuclide methodology, anatomy, physiology, instrumentation and practical applications in Nuclear Medicine. Statistics concerning these course are giving. (author) [es

  5. Methods of Increasing the Performance of Radionuclide Generators Used in Nuclear Medicine: Daughter Nuclide Build-Up Optimisation, Elution-Purification-Concentration Integration, and Effective Control of Radionuclidic Purity

    Directory of Open Access Journals (Sweden)

    Van So Le

    2014-06-01

    Full Text Available Methods of increasing the performance of radionuclide generators used in nuclear medicine radiotherapy and SPECT/PET imaging were developed and detailed for 99Mo/99mTc and 68Ge/68Ga radionuclide generators as the cases. Optimisation methods of the daughter nuclide build-up versus stand-by time and/or specific activity using mean progress functions were developed for increasing the performance of radionuclide generators. As a result of this optimisation, the separation of the daughter nuclide from its parent one should be performed at a defined optimal time to avoid the deterioration in specific activity of the daughter nuclide and wasting stand-by time of the generator, while the daughter nuclide yield is maintained to a reasonably high extent. A new characteristic parameter of the formation-decay kinetics of parent/daughter nuclide system was found and effectively used in the practice of the generator production and utilisation. A method of “early elution schedule” was also developed for increasing the daughter nuclide production yield and specific radioactivity, thus saving the cost of the generator and improving the quality of the daughter radionuclide solution. These newly developed optimisation methods in combination with an integrated elution-purification-concentration system of radionuclide generators recently developed is the most suitable way to operate the generator effectively on the basis of economic use and improvement of purposely suitable quality and specific activity of the produced daughter radionuclides. All these features benefit the economic use of the generator, the improved quality of labelling/scan, and the lowered cost of nuclear medicine procedure. Besides, a new method of quality control protocol set-up for post-delivery test of radionuclidic purity has been developed based on the relationship between gamma ray spectrometric detection limit, required limit of impure radionuclide activity and its measurement

  6. Airborne remote sensing of estuarine intertidal radionuclide concentrations

    International Nuclear Information System (INIS)

    Rainey, M.P.

    1999-08-01

    The ability to map industrial discharges through remote sensing provides a powerful tool in environmental monitoring. Radionuclide effluents have been discharged, under authorization, into the Irish Sea from BNFL (British Nuclear Fuels Pic.) sites at Sellafield and Springfields since 1952. The quantitative mapping of this anthropogenic radioactivity in estuarine intertidal zones is crucial for absolute interpretations of radionuclide transport. The spatial resolutions of traditional approaches e.g. point sampling and airborne gamma surveys are insufficient to support geomorphic interpretations of the fate of radionuclides in estuaries. The research presented in this thesis develops the use of airborne remote sensing to derive high-resolution synoptic data on the distribution of anthropogenic radionuclides in the intertidal areas of the Ribble Estuary, Lancashire, UK. From multidate surface sediment samples a significant relationship was identified between the Sellafield-derived 137 Cs and 241 Am and clay content (r 2 = 0.93 and 0.84 respectively). Detailed in situ, and laboratory, reflectance (0.4-2.5μm) experiments demonstrated that significant relationships exist between Airborne Thematic Mapper (ATM) simulated reflectance and intertidal sediment grain-size. The spectral influence of moisture on the reflectance characteristics of the intertidal area is also evident. This had substantial implications for the timing of airborne image acquisition. Low-tide Daedalus ATM imagery (Natural Environmental Research Council) was collected of the Ribble Estuary on May 30th 1997. Preprocessing and linear unmixing of the imagery allowed accurate sub-pixel determinations of sediment clay content distributions (r 2 = 0.81). Subsequently, the established relationships between 137 Cs and 241 Am and sediment grain-size enabled the radionuclide activity distributions across the entire intertidal area (92 km 2 ) to be mapped at a geomorphic scale (1.75 m). The accuracy of these maps

  7. Measurement of crosstalk contamination in dual isotope imaging by means of energy spectra and images

    International Nuclear Information System (INIS)

    Kojima, Akihiro; Tsuji, Akinori; Ohyama, Yoichi; Nabeshima, Mitsuko; Kira, Tomohiro; Nakashima, Rumi; Tomiguchi, Seiji; Takahashi, Mutsumasa; Matsumoto, Masanori.

    1994-01-01

    The purpose of this study was to estimate the value of crosstalk contamination ratio (CTR) by analyzing energy spectra and scintigraphic images using a phantom and three radionuclides of 201 Tl, 99m Tc and 123 I. A 2 cm x 2 cm plate source filled with single radionuclide was placed in a water tank and its depth changed from 0 cm to 10 cm. Energy spectra and planar images were obtained using a gamma camera with either a low-energy (150 keV) or a medium-energy (200 keV) collimator. The value of CTR was calculated for two combinations : 1) 201 Tl and 99m Tc and 2) 201 Tl and 123 I. The energy window width at a photopeak was 20% for each radionuclide. The data were analyzed in two regions: a region where primary photons were mainly included in (region 1, 2 cm x 2 cm) and a region where both primary and scattered photons were included in (region 2, 10 cm x 10 cm). The results from analyses of the images showed that the CTR of Tl/Tc and Tl/I (0.064-0.101) were almost equal to those of Tc/Tl and I/Tl (0.056-0.148) for the region 1, but the CTR of Tl/Tc and Tl/I (0.212-0.381) were 2 times greater than those of Tc/Tl and I/Tl (0.092-0.172) for the region 2. Furthermore, these results showed good agreement between the CTR by energy spectra and those by images. For imaging with 123 I the medium-energy collimator had less blur than the low-energy collimator, in particular for the smaller source-to-collimator distance. In conclusion, the crosstalk contamination in dual-isotope study affects quantification of two radionuclides' activities. Our results are useful to evaluate images acquired using the dual-isotope technique and develop a new correction method for such crosstalk contamination by analyzing the energy spectra and images obtained. (author)

  8. Application of accelerator-produced short-lived radionuclides in industry

    International Nuclear Information System (INIS)

    Kupsch, H.

    1986-01-01

    Several problems such as corrosion, catalysis, wear, process optimization and diagnosis, damage analysis, arising in idustry can be solved using short-lived radioisotopes. Some examples of technological target designs which have been developed are demonstrated for the radionuclide production based on p,n; d,α; α,n; α,2n; α,p; γ,n; γ,p nuclear reactions. Applications of short-lived radionuclides in plants and processes of electrodeposition and gas concrete production are described. (author)

  9. Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides. Final Report

    International Nuclear Information System (INIS)

    Welch, M.J.

    2012-01-01

    The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N 4 -methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the oxygen

  10. Limitations of radionuclide flow studies in bilateral carotid thrombosis

    International Nuclear Information System (INIS)

    Messert, B.; Tyson, I.B.; Barron, S.A.

    1975-01-01

    Radionuclide angiography as a noninvasive procedure has become an important tool in the evaluation of cerebrovascular diseases. Determinations of arm-to-brain circulation times complemented by the transit times of the radionuclide bolus through the brain afford insight into the functional status of the vascular system of the brain. Delays in perfusion, asymmetries in appearance, and washout of the radionuclide material can be correlated with disease entities. However, as with many procedures elevated to the status of a screening test, the possibility of false-positive and false-negative results exists. Two cases of bilateral carotid occlusion are presented, showing normal or only delayed, fairly symmetrical brain perfusion. The appearance of the radionuclide flow in the neck in AP and lateral views gave no suggestion of the involved deficits. Even multiple-projection imaging might fail to demonstrate major vascular obstructions. However, attentive study of these projections might yield interesting evidence of unexpected collateral flow systems. (U.S.)

  11. Economic and technical assay of the application of radionuclide technology

    International Nuclear Information System (INIS)

    Emrich, F.G.

    1976-05-01

    The dynamically loaded components of combustion engines undergo wear during operation as a function of the operating points and the operating parameters selected. Radionuclide measurement methods developed in the Federal Republic of Germany in the LIT laboratory of Gesellschaft fuer Kernforschung allow to determine the wear of machine components during operation, contrary to conventional length measurement techniques. In the first part of this work the existing wear problems will be analyzed and investigations will be made into the capacities of conventional and radionuclide measurement methods. Based on this, a cost-benefit analysis system was developed for evaluation under technical and economical aspects of the use of different measurement methods allowing to solve detailed wear problems. This system furnishes results on the respective optimum wear measurement method relating to the actual problem and taking into account the relevant technical and economical boundary conditions. (orig.) [de

  12. Radionuclide cisternography

    International Nuclear Information System (INIS)

    Song, H.H.

    1980-01-01

    The purpose of this thesis is to show that radionuclide cisternography makes an essential contribution to the investigation of cerebrospinal fluid (CSF) dynamics, especially for the investigation of hydrocephalus. The technical details of radionuclide cisternography are discussed, followed by a description of the normal and abnormal radionuclide cisternograms. The dynamics of CFS by means of radionuclide cisternography were examined in 188 patients in whom some kind of hydrocephalus was suspected. This study included findings of anomalies associated with hydrocephalus in a number of cases, such as nasal liquorrhea, hygromas, leptomeningeal or porencephalic cysts. The investigation substantiates the value of radionuclide cisternography in the diagnosis of disturbances of CSF flow. The retrograde flow of radiopharmaceutical into the ventricular system (ventricular reflux) is an abnormal phenomenon indicating the presence of communicating hydrocephalus. (Auth.)

  13. Principles of radionuclide studies of the genitourinary system

    International Nuclear Information System (INIS)

    Kim, E.E.; Pjura, G.A.; Lowry, P.A.

    1988-01-01

    The clinical assessment of renal diseases with radionuclide procedures is discussed. It has achieved general recognition only during the last decade. The proper assessment of renal function with radionuclides provides useful information for the management of patients with renal disease and renal transplant recipients. Renal imaging with radionuclides gives some information on morphology and the integrity of the urinary collecting system, but more importantly it provides functional information that may include renal blood flow or effective renal plasma flow (ERPF), glomerular filtration rate (GFR), the quantitation of differential renal function, the evaluation of vesicoureteral reflux, the quantitation of postvoiding residual urine volume, and the differential diagnosis of testicular disease. Acute renal failure resulting from acute tubular necrosis, hepatorenal syndrome, acute interstitial nephirits, cortical necrosis, renal artery embolism, or acute pyelonephritis may be recognized by radionuclide studies. Data useful in the diagnosis and management of the patient with obstructive or reflux nephropathy also may be obtained. Radionuclide studies in patients with chronic renal failure may reveal such causes as renal artery stenosis, chronic pyelonephritis, or infiltrative renal disease. Finally, nuclear study in transplant recipients is useful to help differentiate rejection from acute tubular necrosis and other causes of reduced renal function

  14. Migration of radionuclides in geologic media: Fundamental research needs

    International Nuclear Information System (INIS)

    Reed, D.T.; Zachara, J.M.; Wildung, R.E.; Wobber, F.J.

    1990-01-01

    An assessment of the fundamental research needs in understanding and predicting the migration of radionuclides in the subsurface is provided. Emphasis is on the following three technical areas: (1) aqueous speciation of radionuclides, (2) the interaction of radionuclides with substrates, and (3) intermediate-scale interaction studies. This research relates to important issues associated with environmental restoration and remediation of DOE sites contaminated with mixed radionuclide-organic wastes. 64 refs., 1 fig., 1 tab

  15. DOTA-PESIN, a DOTA-conjugated bombesin derivative designed for the imaging and targeted radionuclide treatment of bombesin receptor-positive tumours

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hanwen; Maecke, Helmut R. [University Hospital Basel, Division of Radiological Chemistry, Department of Radiology, Basel (Switzerland); Schuhmacher, Jochen; Eisenhut, Michael [German Cancer Research Centre, Department of Radiopharmaceutical Chemistry, Heidelberg (Germany); Waser, Beatrice; Reubi, Jean Claude [University of Berne, Division of Cell Biology and Experimental Cancer Research, Institute of Pathology, P.O. Box 62, Berne (Switzerland); Wild, Damian [University Hospital, Clinic and Institute of Nuclear Medicine, Department of Radiology, Basel (Switzerland)

    2007-08-15

    We aimed at designing and developing a novel bombesin analogue, DOTA-PEG{sub 4}-BN(7-14) (DOTA-PESIN), with the goal of labelling it with {sup 67/68}Ga and {sup 177}Lu for diagnosis and radionuclide therapy of prostate and other human cancers overexpressing bombesin receptors. The 8-amino acid peptide bombesin (7-14) was coupled to the macrocyclic chelator DOTA via the spacer 15-amino-4,7,10,13-tetraoxapentadecanoic acid (PEG{sub 4}). The conjugate was complexed with Ga(III) and Lu(III) salts. The GRP receptor affinity and the bombesin receptor subtype profile were determined in human tumour specimens expressing the three bombesin receptor subtypes. Internalisation and efflux studies were performed with the human GRP receptor cell line PC-3. Xenografted nude mice were used for biodistribution. [Ga{sup III}/Lu{sup III}]-DOTA-PESIN showed good affinity to GRP and neuromedin B receptors but no affinity to BB3. [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN internalised rapidly into PC-3 cells whereas the efflux from PC-3 cells was relatively slow. In vivo experiments showed a high and specific tumour uptake and good retention of [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN. [{sup 67}Ga/{sup 177}Lu]-DOTA-PESIN highly accumulated in GRP receptor-expressing mouse pancreas. The uptake specificity was demonstrated by blocking tumour uptake and pancreas uptake. Fast clearance was found from blood and all non-target organs except the kidneys. High tumour-to-normal tissue ratios were achieved, which increased with time. PET imaging with [{sup 68}Ga]-DOTA-PESIN was successful in visualising the tumour at 1 h post injection. Planar scintigraphic imaging showed that the {sup 177}Lu-labelled peptide remained in the tumour even 3 days post injection. The newly designed ligands have high potential with regard to PET and SPECT imaging with {sup 68/67}Ga and targeted radionuclide therapy with {sup 177}Lu. (orig.)

  16. Development and testing of radionuclide transport models for fractured crystalline rock. An overview of the Nagra/JNC radionuclide retardation programme

    International Nuclear Information System (INIS)

    Ota, Kunio; Alexander, W.R.

    2001-01-01

    The joint Nagra/JNC radionuclide Retardation Programme has now been ongoing for more thean 10 years with the main aim of direct testing of radionuclide transport models for fractured crystalline rocks in as realistic a manner as possible. A large programme of field, laboratory and natural analogue studies has been carried out at the Grimsel Test Site in the central Swiss Alps. The understanding and modelling of both the processes and the structures influencing radionuclide transport in fractured crystalline rocks have matured as has the experimental technology, which has contributed to develop confidence in the applicability of the underlying research models in a repository performance assessment. In this report, the successes and set-backs of this programme are discussed as is the general approach to the thorough testing of the process models and of model assumptions. (author)

  17. A survey of passive technology for digital image forensics

    Institute of Scientific and Technical Information of China (English)

    LUO Weiqi; QU Zhenhua; PAN Feng; HUANG Jiwu

    2007-01-01

    Over the past years,digital images have been widely used in the Internet and other applications.Whilst image processing techniques are developing at a rapid speed,tampering with digital images without leaving any obvious traces becomes easier and easier.This may give rise to some problems such as image authentication.A new passive technology for image forensics has evolved quickly during the last few years.Unlike the signature-based or watermark-based methods,the new technology does not need any signature generated or watermark embedded in advance,it assumes that different imaging devices or processing would introduce different inherent patterns into the output images.These underlying patterns are consistent in the original untampered images and would be altered after some kind of manipulations.Thus,they can be used as evidence for image source identification and alteration detection.In this paper,we will discuss this new forensics technology and give an overview of the prior literatures.Some concluding remarks are made about the state of the art and the challenges in this novel technology.

  18. Tomographic imaging

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Tomography is used to image anatomy of organs as in the case of CT and MRI or image body functions as in the case of SPECT and PET. The theory of reconstruction applies equally well to CT, SPECT and PET with a minor differences. The main difference between SPECT and PET is that SPECT images single photon emitters (radionuclides) which emit normal gamma rays (like Tc-99m), whereas PET images positron emitting radionuclides such as O 15 or F 18 . The word tomography means drawing of the body. Every tomography results in an image of the inside of the body and is represented as a slice. (author)

  19. Neuroendocrine Tumours : From Radiomolecular Imaging to Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    GEORGIOS eLIMOURIS

    2012-02-01

    Full Text Available Transhepatic radionuclide infusion (THRI has been introduced as a new treatment approach for unresectable liver neuroendocrine metastatic lesions with the prerequisite of a positive In-111 Pentetreotide (Octreoscan. Patients with multiple liver neuroendocrine metastases can be locally treated after selective hepatic artery catheterization and infusion of radiolabelled somatostatin analogues, and in case of extra-hepatic secondary spread, after simple i.v. application. According to the world wide references, the average dose per session to each patient is 6.3±0.3 GBq (~ 160-180 mCi of In-111-DTPA-Phe1- Pentetreotide, 10-12 fold in total, administered monthly or of 4.1± 0.2 GBq (~105-116 mCi of Y-90 DOTA TOC, 3 fold in total or of 7.0 ± 0.4 GBq (~178-200 mCi of Lu-177 DOTA TATE, 4-6 fold in total (the choice of which being based on the tumor size, assessed by CT or MRI . Follow-up at monthly intervals has to be performed by means of ultrasonography (US. Treat- ment response has to be assessed according to the WHO criteria (RECIST or SWOG.

  20. Radionuclide evaluation of renal transplants

    International Nuclear Information System (INIS)

    Yang Hong; Zhao Deshan

    2000-01-01

    Radionuclide renal imaging and plasma clearance methods can quickly quantitate renal blood flow and function in renal transplants. They can diagnose acute tubular necrosis and rejection, renal scar, surgical complications such as urine leaks, obstruction and renal artery stenosis after renal transplants. At the same time they can assess the therapy effect of renal transplant complications and can also predict renal transplant survival from early post-operative function studies

  1. A study of radionuclide dispersion by river systems, using GIS and remote sensing techniques

    International Nuclear Information System (INIS)

    Borghuis, Sander; Brown, Justin; Steenhuisen, Frits; Skorve, Johnny

    2000-01-01

    The Krasnoyarsk Mining and Chemical Combine in Zheleznogorsk, Russia, is situated on the banks of the Yenisey river. The combine consists of three RBMK-type graphite moderate reactors, a reprocessing plant for the production of weapons-grade plutonium and storage facilities for nuclear waste. Discharges of radionuclides into the Yenisey river were either part of normal operation procedures or caused by accidental releases (Strand et al., 1997). So far, little is known about the transport and fate of the radioactive contaminants in the areas downstream of the Krasnoyarsk CC that are influenced by the Yenisey river system. Aim is to comprehend the dispersion of radionuclides through the river system. Remotely sensed and field study information are combined in a geographical information system (GIS) to study the processes leading to the dispersion of sediment-bound radionuclides carried by the river system. Since the extent of the study area is several thousands or kilometres of river and adjacent flood plains, use is made of a record of remotely sensed (satellite) images that are handled by the GIS. Panchromatic, high resolution satellite images as well as multispectral Landsat MSS and TM images were compiled for the area of interest. The panchromatic images were taken in a period during which the facility was in operation (1960-1972) and obtained for intervals of circa 6 months. A time series of satellite images enables the identification of erosion and sedimentation zones. The behaviour and fate of particle-reactive radionuclides, e.g. 239,240 Pu and to large extent 137 Cs, will be closely related to the movement of sediment. With respect to the behaviour and fate of more conservative radionuclides as 90 Sr, information is required accounting for fractionation between the particulate and aqueous phases. Stereo images are used to comprehend the geomorphology of the Yenisey river systems, focused on classification of sedimentary deposits. Landsat MSS and TM with five

  2. The vertical distribution of radionuclides in a Ribble Estuary saltmarsh: transport and deposition of radionuclides

    International Nuclear Information System (INIS)

    Brown, J.E.; McDonald, P.; Parker, A.; Rae, J.E.

    1999-01-01

    Routine discharges of low-level liquid radioactive waste by British Nuclear Fuels plc (BNFL) at Sellafield and Springfields have resulted in enhanced levels of radionuclides in sediments of the Ribble Estuary, NW England, UK. Variations in radionuclide concentrations ( 137 Cs, 230 Th, and 239240 Pu) with depth in a mature saltmarsh core were analysed in order to investigate historical discharge trends and waste-dispersal mechanisms. Core samples from Longton/Hutton Marsh were analysed by gamma-spectrometry and α-spectrometry for radionuclides and by laser granulometry to establish grain-size variations with depth. Distinct subsurface maxima were present for 137 Cs and 239240 Pu with activities as high as 4500 Bq kg -1 for 137 Cs and 600 Bq kg -1 for 239240 Pu. Thorium-230 exhibited complex activity profiles with depth, specific activities ranging between 200 and 2400 Bq kg -1 . The vertical distributions of Sellafield-derived radionuclides ( 137 Cs and 239240 Pu) in mature saltmarsh deposits reflect the time-integrated discharge pattern from Sellafield, implying a transport mechanism that has involved the mixing of sediment labelled with radioactivity from recent discharges and sediment labelled from historical discharge events before deposition. A mechanism involving the transport of contaminated silt therefore seems to dominate. The vertical distribution of Springfields-derived 230 Th in the same areas reflects the annual gross-α discharge pattern from BNFL Springfields. In contrast to the Sellafield-derived radionuclides, a fairly rapid transport mechanism from source to sink is implied, with little or no time for mixing with radionuclides discharged years earlier. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Influence of riboflavin on the reduction of radionuclides by Shewanella oneidenis MR-1.

    Science.gov (United States)

    Cherkouk, Andrea; Law, Gareth T W; Rizoulis, Athanasios; Law, Katie; Renshaw, Joanna C; Morris, Katherine; Livens, Francis R; Lloyd, Jonathan R

    2016-03-28

    Uranium (as UO2(2+)), technetium (as TcO4(-)) and neptunium (as NpO2(+)) are highly mobile radionuclides that can be reduced enzymatically by a range of anaerobic and facultatively anaerobic microorganisms, including Shewanella oneidensis MR-1, to poorly soluble species. The redox chemistry of Pu is more complicated, but the dominant oxidation state in most environments is highly insoluble Pu(IV), which can be reduced to Pu(III) which has a potentially increased solubility which could enhance migration of Pu in the environment. Recently it was shown that flavins (riboflavin and flavin mononucleotide (FMN)) secreted by Shewanella oneidensis MR-1 can act as electron shuttles, promoting anoxic growth coupled to the accelerated reduction of poorly-crystalline Fe(III) oxides. Here, we studied the role of riboflavin in mediating the reduction of radionuclides in cultures of Shewanella oneidensis MR-1. Our results demonstrate that the addition of 10 μM riboflavin enhances the reduction rate of Tc(VII) to Tc(IV), Pu(IV) to Pu(III) and to a lesser extent, Np(V) to Np(IV), but has no significant influence on the reduction rate of U(VI) by Shewanella oneidensis MR-1. Thus riboflavin can act as an extracellular electron shuttle to enhance rates of Tc(VII), Np(V) and Pu(IV) reduction, and may therefore play a role in controlling the oxidation state of key redox active actinides and fission products in natural and engineered environments. These results also suggest that the addition of riboflavin could be used to accelerate the bioremediation of radionuclide-contaminated environments.

  4. Research on fast Fourier transforms algorithm of huge remote sensing image technology with GPU and partitioning technology.

    Science.gov (United States)

    Yang, Xue; Li, Xue-You; Li, Jia-Guo; Ma, Jun; Zhang, Li; Yang, Jan; Du, Quan-Ye

    2014-02-01

    Fast Fourier transforms (FFT) is a basic approach to remote sensing image processing. With the improvement of capacity of remote sensing image capture with the features of hyperspectrum, high spatial resolution and high temporal resolution, how to use FFT technology to efficiently process huge remote sensing image becomes the critical step and research hot spot of current image processing technology. FFT algorithm, one of the basic algorithms of image processing, can be used for stripe noise removal, image compression, image registration, etc. in processing remote sensing image. CUFFT function library is the FFT algorithm library based on CPU and FFTW. FFTW is a FFT algorithm developed based on CPU in PC platform, and is currently the fastest CPU based FFT algorithm function library. However there is a common problem that once the available memory or memory is less than the capacity of image, there will be out of memory or memory overflow when using the above two methods to realize image FFT arithmetic. To address this problem, a CPU and partitioning technology based Huge Remote Fast Fourier Transform (HRFFT) algorithm is proposed in this paper. By improving the FFT algorithm in CUFFT function library, the problem of out of memory and memory overflow is solved. Moreover, this method is proved rational by experiment combined with the CCD image of HJ-1A satellite. When applied to practical image processing, it improves effect of the image processing, speeds up the processing, which saves the time of computation and achieves sound result.

  5. Potential radionuclide emissions from stacks on the Hanford site, Part 1: Dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Davis, W.E.; Barnett, J.M. [Westinghouse Hanford Company, Richland, WA (United States)

    1995-02-01

    On February 3, 1993, the U.S. Department of Energy, Richland Operations Office received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the U.S. Environmental Protection Agency, Region 10. The Compliance Order requires RL to evaluate all radionuclide emission points at the Hanford Site to determine which are subject to continuous emission monitoring requirements in 40 CFR 61, Subpart H, and to continuously monitor radionuclide emissions in accordance with requirements in 40 CFR 61.93. The Information Request required RL to provide a written Compliance Plan to meet the requirements of the Compliance Order. A Compliance Plan was submitted to EPA, Region 10, on April 30, 1993. The Compliance Plan specified that a dose assessment would be performed for 84 Westinghouse Hanford Company stacks registered with the Washington State Department of Health on the Hanford Site. Stacks that have the potential emissions to cause an effective dose equivalent to a maximum exposed individual greater than 0.1 mrem/y must be monitored continuously for radionuclide emissions. Five methods were approved by EPA, Region 10 for performing the assessments: Release Fractions from Appendix D of 40 CFR 61, Back Calculations Using A HEPA Filtration Factor, Nondestructive Assay of HEPA Filters, A Spill Release Fraction, and Upstream of HEPA Filter Air Concentrations. The first two methods were extremely conservative for estimating releases. The third method, which used a state-of-the-art portable gamma spectrometer, yielded surprising results from the distribution of radionuclides on the HEPA filters. All five methods are described. Assessments using a HEPA Filtration Factor for back calculations identified 32 stacks that would have emissions that would cause an EDE to the MEI greater than 0.1 mrem y{sup {minus}1}. The number was reduced to 15 stacks when the other methods were applied. The paper discusses reasons for the overestimates.

  6. Phytoremediation of soils contaminated with toxic elements and radionuclides

    International Nuclear Information System (INIS)

    Cornish, J.E.; Goldberg, W.C.; Levine, R.S.; Benemann, J.R.

    1995-01-01

    At many US Department of Energy (US DOE) facilities and other sites, surface soils over relatively large areas are contaminated with heavy metals, radionuclides, and other toxic elements, often at only a relatively small factor above regulatory action levels. Cleanup of such sites presents major challenges, because currently available soil remediation technologies can be very expensive. In response, the US DOE's Office of Technology Development, through the Western Environmental Technology Office, is sponsoring research in the area of phytoremediation. Phytoremediation is an emerging technology that uses higher plants to transfer toxic elements and radionuclides from surface soils into aboveground biomass. Some plants, termed hyperaccumulators, take up toxic elements in substantial amounts, resulting in concentrations in aboveground biomass over 100 times those observed with conventional plants. After growth, the plant biomass is harvested, and the toxic elements are concentrated and reclaimed or disposed of. As growing, harvesting, and processing plant biomass is relatively inexpensive, phytoremediation can be a low-cost technology for remediation of extensive areas having lightly to moderately contaminated soils. This paper reviews the potential of hyper- and moderate accumulator plants in soil remediation, provides some comparative cost estimates, and outlines ongoing work initiated by the US DOE

  7. Natural radionuclides in soil profiles surrounding the largest coal-fired power plant in Serbia

    Directory of Open Access Journals (Sweden)

    Tanić Milan N.

    2016-01-01

    Full Text Available This study evaluates the influence of the largest Serbian coal-fired power plant on radionuclide concentrations in soil profiles up to 50 cm in depth. Thirty soil profiles were sampled from the plant surroundings (up to 10 km distance and analyzed using standard methods for soil physicochemical properties and gamma ray spectrometry for specific activities of natural radionuclides (40K, 226Ra and 232Th. Spatial and vertical distribution of radionuclides was determined and analyzed to show the relations between the specific activities in the soil and soil properties and the most influential factors of natural radionuclide variability were identified. The radiological indices for surface soil were calculated and radiological risk assessment was performed. The measured specific activities were similar to values of background levels for Serbia. The sampling depth did not show any significant influence on specific activities of natural radionuclides. The strongest predictor of specific activities of the investigated radionuclides was soil granulometry. All parameters of radiological risk assessment were below the recommended values and adopted limits. It appears that the coal-fired power plant does not have a significant impact on the spatial and vertical distribution of natural radionuclides in the area of interest, but technologically enhanced natural radioactivity as a consequence of the plant operations was identified within the first 1.5 km from the power plant. [Projekat Ministarstva nauke Republike Srbije br. III43009 i br. III41005

  8. Innovative fossil fuel fired vitrification technology for soil remediation. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    Vortec has successfully completed Phase 1 of the ``Innovative Fossil Fuel Fired Vitrification Technology for Soil Remediation`` program. The Combustion and Melting System (CMS) has processed 7000 pounds of material representative of contaminated soil that is found at DOE sites. The soil was spiked with Resource Conservation and Recovery Act (RCRA) metals surrogates, an organic contaminant, and a surrogate radionuclide. The samples taken during the tests confirmed that virtually all of the radionuclide was retained in the glass and that it did not leach to the environment-as confirmed by both ANS 16.1 and Toxicity Characteristic Leaching Procedure (TCLP) testing. The organic contaminant, anthracene, was destroyed during the test with a Destruction and Removal Efficiency (DRE) of at least 99.99%. RCRA metal surrogates, that were in the vitrified product, were retained and did not leach to the environment as confirmed by the TCLP testing. Semi-volatile RCRA metal surrogates were captured by the Air Pollution Control (APC) system, and data on the amount of metal oxide particulate and the chemical composition of the particulate were established for use in the Phase 2 APC subsystem design.

  9. Progress of radionuclide diagnostic methods in central nervous system diseases

    International Nuclear Information System (INIS)

    Badmaev, K.N.; Zen'kovich, S.G.

    1982-01-01

    A summarry on modern radionuclide diagnosis achivements of central nervous system diseases is presented. Most optimal tumorotropic preparations and compounds in the view of decreasing irradiation does and optimazing image are given

  10. Aligning physics and physiology: Engineering antibodies for radionuclide delivery.

    Science.gov (United States)

    Tsai, Wen-Ting K; Wu, Anna M

    2018-03-14

    The exquisite specificity of antibodies and antibody fragments renders them excellent agents for targeted delivery of radionuclides. Radiolabeled antibodies and fragments have been successfully used for molecular imaging and radioimmunotherapy (RIT) of cell surface targets in oncology and immunology. Protein engineering has been used for antibody humanization essential for clinical applications, as well as optimization of important characteristics including pharmacokinetics, biodistribution, and clearance. Although intact antibodies have high potential as imaging and therapeutic agents, challenges include long circulation time in blood, which leads to later imaging time points post-injection and higher blood absorbed dose that may be disadvantageous for RIT. Using engineered fragments may address these challenges, as size reduction and removal of Fc function decreases serum half-life. Radiolabeled fragments and pretargeting strategies can result in high contrast images within hours to days, and a reduction of RIT toxicity in normal tissues. Additionally, fragments can be engineered to direct hepatic or renal clearance, which may be chosen based on the application and disease setting. This review discusses aligning the physical properties of radionuclides (positron, gamma, beta, alpha, and Auger emitters) with antibodies and fragments and highlights recent advances of engineered antibodies and fragments in preclinical and clinical development for imaging and therapy. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Chapter 13. Radionuclides in medicine

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with problems connected with using of radionuclides in medicine. Methods of treatment with using of radionuclides are reviewed. Chapter consists of next parts: (1) Remotion of thyroid gland; (2) Treatment of cerebrally tumour in nuclear reactor; (3) Artificial heart

  12. How to change students' images of science and technology

    Science.gov (United States)

    Scherz, Zahava; Oren, Miri

    2006-11-01

    This paper examines the images middle school students have of science and technology, the workplaces, and the relevant professions. It also describes the effect on these images caused by an instructional initiative, Investigation into Science and Technology (IST), designed to introduce students to science and technology in the real life. Students' images were delineated via questionnaires, drawing tasks, and interviews before and after their participation in the IST program. The sample consisted of 100 students from six classes (eighth or ninth grade) of three schools. We found that before the IST intervention students' images about the scientific or technological environments were superficial, unreal, and even incorrect. Their impressions of the characteristics of scientists and technologists were superficial, misleading, and sometimes reflected ignorance. The findings demonstrate that the IST program stimulated a positive effect on students' images. Their preconceptions were altered in several dimensions: in the cognitive dimension, from superficial and vague to precise and correct images; in the perceptive dimension, from stereotypic to rational and open-minded images; and in the affective dimension, from negative to positive attitudes.

  13. ACCELERATED SITE TECHNOLOGY DEPLOYMENT COST AND PERFORMANCE REPORT COMPARABILITY OF ISOCS INSTRUMENT IN RADIONUCLIDE CHARACTERICATION AT BROOKHAVEN NATIONAL LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    KALB,P.; LUCKETT,L.; MILLER,K.; GOGOLAK,C.; MILIAN,L.

    2001-03-01

    This report describes a DOE Accelerated Site Technology Deployment project being conducted at Brookhaven National Laboratory to deploy innovative, radiological, in situ analytical techniques. The technologies are being deployed in support of efforts to characterize the Brookhaven Graphite Research Reactor (BGRR) facility, which is currently undergoing decontamination and decommissioning. This report focuses on the deployment of the Canberra Industries In Situ Object Counting System (ISOCS) and assesses its data comparability to baseline methods of sampling and laboratory analysis. The battery-operated, field deployable gamma spectrometer provides traditional spectra of counts as a function of gamma energy. The spectra are then converted to radionuclide concentration by applying innovative efficiency calculations using monte carlo statistical methods and pre-defined geometry templates in the analysis software. Measurement of gamma emitting radionuclides has been accomplished during characterization of several BGRR components including the Pile Fan Sump, Above Ground Ducts, contaminated cooling fans, and graphite pile internals. Cs-137 is the predominant gamma-emitting radionuclide identified, with smaller quantities of Co-60 and Am-241 detected. The Project used the Multi-Agency Radiation Survey and Site Investigation Manual guidance and the Data Quality Objectives process to provide direction for survey planning and data quality assessment. Analytical results have been used to calculate data quality indicators (DQI) for the ISOCS measurements. Among the DQIs assessed in the report are sensitivity, accuracy, precision, bias, and minimum detectable concentration. The assessment of the in situ data quality using the DQIs demonstrates that the ISOCS data quality can be comparable to definitive level laboratory analysis when the field instrument is supported by an appropriate Quality Assurance Project Plan. A discussion of the results obtained by ISOCS analysis of

  14. ACCELERATED SITE TECHNOLOGY DEPLOYMENT COST AND PERFORMANCE REPORT COMPARABILITY OF ISOCS INSTRUMENT IN RADIONUCLIDE CHARACTERICATION AT BROOKHAVEN NATIONAL LABORATORY

    International Nuclear Information System (INIS)

    KALB, P.; LUCKETT, L.; MILLER, K.; GOGOLAK, C.; MILIAN, L.

    2001-01-01

    This report describes a DOE Accelerated Site Technology Deployment project being conducted at Brookhaven National Laboratory to deploy innovative, radiological, in situ analytical techniques. The technologies are being deployed in support of efforts to characterize the Brookhaven Graphite Research Reactor (BGRR) facility, which is currently undergoing decontamination and decommissioning. This report focuses on the deployment of the Canberra Industries In Situ Object Counting System (ISOCS) and assesses its data comparability to baseline methods of sampling and laboratory analysis. The battery-operated, field deployable gamma spectrometer provides traditional spectra of counts as a function of gamma energy. The spectra are then converted to radionuclide concentration by applying innovative efficiency calculations using monte carlo statistical methods and pre-defined geometry templates in the analysis software. Measurement of gamma emitting radionuclides has been accomplished during characterization of several BGRR components including the Pile Fan Sump, Above Ground Ducts, contaminated cooling fans, and graphite pile internals. Cs-137 is the predominant gamma-emitting radionuclide identified, with smaller quantities of Co-60 and Am-241 detected. The Project used the Multi-Agency Radiation Survey and Site Investigation Manual guidance and the Data Quality Objectives process to provide direction for survey planning and data quality assessment. Analytical results have been used to calculate data quality indicators (DQI) for the ISOCS measurements. Among the DQIs assessed in the report are sensitivity, accuracy, precision, bias, and minimum detectable concentration. The assessment of the in situ data quality using the DQIs demonstrates that the ISOCS data quality can be comparable to definitive level laboratory analysis when the field instrument is supported by an appropriate Quality Assurance Project Plan. A discussion of the results obtained by ISOCS analysis of

  15. Speciation analysis of radionuclides

    International Nuclear Information System (INIS)

    Salbu, B.

    2010-01-01

    Full text: Naturally occurring and artificially produced radionuclides in the environment can be present in different physico-chemical forms (i. e. radionuclide species) varying in size (nominal molecular mass), charge properties and valence, oxidation state, structure and morphology, density, complexing ability etc. Low molecular mass (LMM) species are believed to be mobile and potentially bioavailable, while high molecular mass (HMM) species such as colloids, polymers, pseudocolloids and particles are considered inert. Due to time dependent transformation processes such as mobilization of radionuclide species from solid phases or interactions of mobile and reactive radionuclide species with components in soils and sediments, however, the original distribution of radionuclides deposited in ecosystems will change over time and influence the ecosystem behaviour. To assess the environmental impact from radionuclide contamination, information on radionuclide species deposited, interactions within affected ecosystems and the time-dependent distribution of radionuclide species influencing mobility and biological uptake is essential. The development of speciation techniques to characterize radionuclide species in waters, soils and sediments should therefore be essential for improving the prediction power of impact and risk assessment models. The present paper reviews fractionation techniques which should be utilised for radionuclide speciation purposes. (author)

  16. Synthesis of hypoxia imaging agent 1-(5-deoxy-5-fluoro-α-D-arabinofuranosyl)-2-nitroimidazole using microfluidic technology

    International Nuclear Information System (INIS)

    Bouvet, Vincent R.; Wuest, Melinda; Wiebe, Leonard I.; Wuest, Frank

    2011-01-01

    Introduction: Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-α-D-arabinofuranosyl)-2-nitroimidazole ([ 18 F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [ 18 F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice. Methods: Radiosyntheses were performed using the NanoTek Microfluidic Synthesis System (Advion BioSciences, Inc.). Optimal reaction conditions were studied through screening different reaction parameters like temperature, flow rate, residency time, concentration of the labeling precursor (1-(2,3-di-O-acetyl-5-O-tosyl-α-D-arabinofuranosyl)-2-nitroimidazole) and the applied volume ratio between the labeling precursor and [ 18 F]fluoride. Results: Optimized reaction conditions at low radioactivity levels (1 to 50 MBq) afforded 63% (decay-corrected) of HPLC-purified [ 18 F]FAZA within 25 min. Higher radioactivity levels (0.4 to 2.1 GBq) gave HPLC-purified [ 18 F]FAZA in radiochemical yields of 40% (decay-corrected) within 60 min at a specific activity in the range of 70 to 150 GBq/μmol. Small animal PET studies in EMT-6 tumor-bearing mice showed radioactivity accumulation in the tumor (SUV 20min 0.74 ± 0.08) resulting in an increasing tumor-to-muscle ratio over time. Conclusions: Microfluidic technology is an ideal method for the rapid and efficient radiosynthesis of [ 18 F]FAZA for preclinical radiopharmacological studies. Careful analysis of various reaction parameters is an

  17. Innovative fossil fuel fired vitrification technology for soil remediation. Volume 1, Phase 1: Annual report, September 28, 1992--August 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    Vortex has successfully completed Phase 1 of the ``Innovative Fossil Fuel Fired Vitrification Technology for Soil Remediation`` program with the Department of Energy (DOE) Morgantown Energy Technology Center (METC). The Combustion and Melting System (CMS) has processed 7000 pounds of material representative of contaminated soil that is found at DOE sites. The soil was spiked with Resource Conversation and Recovery Act (RCRA) metals surrogates, an organic contaminant, and a surrogate radionuclide. The samples taken during the tests confirmed that virtually all of the radionuclide was retained in the glass and that it did not leach to the environment. The organic contaminant, anthracene, was destroyed during the test with a Destruction and Removal Efficiency (DRE) of at least 99.99%. RCRA metal surrogates, that were in the vitrified product, were retained and will not leach to the environment--as confirmed by the TCLP testing. Semi-volatile RCRA metal surrogates were captured by the Air Pollution Control (APC) system, and data on the amount of metal oxide particulate and the chemical composition of the particulate were established for use in the Phase 2 APC system design. This topical report will present a summary of the activities conducted during Phase 1 of the ``Innovative Fossil Fuel Fired Vitrification Technology for Soil Remediation`` program. The report includes the detail technical data generated during the experimental program and the design and cost data for the preliminary Phase 2 plant.

  18. Identification of hip surface arthroplasty failures with TcSC/TcmDP radionuclide imaging

    International Nuclear Information System (INIS)

    Thomas, B.J.; Amstutz, H.C.; Mai, L.L.; Webber, M.M.

    1982-01-01

    The roentgenographic identification of femoral component loosening after hip surface arthroplasty is often impossible because the metallic femoral component obscures the bone-cement interface. The use of combined technetium sulfur colloid and technetium methylene diphosphonate radionuclide imaging has been especially useful in the diagnosis of loosening. In 40 patients, follow-up combined TcSC and TcmDP scans at an average of three, nine, and 27 months postoperation revealed significant differences in the isotope uptakes in patients who had loose prostheses compared with those without complications. Scans were evaluated by first dividing them into eight anatomical regions and then rating the uptake in each region or 'zone' on a five-point scale. Results were compared using the Student's t-test and differences were noted between normal controls and patients who had femoral component loosening. Combining both TcSC and TcmDP studies increased the statistical significance obtained when comparing patients who had complications to those in the control group

  19. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  20. Activation cross sections for the generation of long-lived radionuclides of importance in fusion reactor technology

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1993-11-01

    The present report contains the Summary of the Second IAEA Research Co-ordination Meeting (RCM) on ''Activation Cross Sections for the Generation of Long-Lived Radionuclides of Importance in Fusion Reactor Technology'' which was hosted by TSI Research at Del Mar near San Diego and held from 29 to 30 April 1993. This RCM was organized by the IAEA Nuclear Data Section (NDS), with the cooperation and assistance of local organizers from TSI Research and Westinghouse Hanford Company. Tables of 14 MeV cross sections and cross sections below 14 MeV are included. The papers prepared and presented by the participants at the meeting has been published as separate report INDC(NDS)-286/L. 3 tabs

  1. Patient-Specific Dosimetry and Radiobiological Modeling of Targeted Radionuclide Therapy Grant - final report

    Energy Technology Data Exchange (ETDEWEB)

    George Sgouros, Ph.D.

    2007-03-20

    The broad, long-term objectives of this application are to 1. develop easily implementable tools for radionuclide dosimetry that can be used to predict normal organ toxicity and tumor response in targeted radionuclide therapy; and 2. to apply these tools to the analysis of clinical trial data in order to demonstrate dose-response relationships for radionuclide therapy treatment planning. The work is founded on the hypothesis that robust dose-response relationships have not been observed in targeted radionuclide therapy studies because currently available internal dosimetry methodologies are inadequate, failing to adequately account for individual variations in patient anatomy, radionuclide activity distribution/kinetics, absorbed dose-distribution, and absorbed dose-rate. To reduce development time the previously available software package, 3D-ID, one of the first dosimetry software packages to incorporate 3-D radionuclide distribution with individual patient anatomy; and the first to be applied for the comprehensive analysis of patient data, will be used as a platform to build the functionality listed above. The following specific aims are proposed to satisfy the long-term objectives stated above: 1. develop a comprehensive and validated methodology for converting one or more SPECT images of the radionuclide distribution to a 3-D representation of the cumulated activity distribution; 2. account for differences in tissue density and atomic number by incorporating an easily implementable Monte Carlo methodology for the 3-D dosimetry calculations; 3. incorporate the biologically equivalent dose (BED) and equivalent uniform dose (EUD) models to convert the spatial distribution of absorbed dose and dose-rate into equivalent single values that account for differences in dose uniformity and rate and that may be correlated with tumor response and normal organ toxicity; 4. test the hypothesis stated above by applying the resulting package to patient trials of targeted

  2. Inverse problem in radionuclide transport

    International Nuclear Information System (INIS)

    Yu, C.

    1988-01-01

    The disposal of radioactive waste must comply with the performance objectives set forth in 10 CFR 61 for low-level waste (LLW) and 10 CFR 60 for high-level waste (HLW). To determine probable compliance, the proposed disposal system can be modeled to predict its performance. One of the difficulties encountered in such a study is modeling the migration of radionuclides through a complex geologic medium for the long term. Although many radionuclide transport models exist in the literature, the accuracy of the model prediction is highly dependent on the model parameters used. The problem of using known parameters in a radionuclide transport model to predict radionuclide concentrations is a direct problem (DP); whereas the reverse of DP, i.e., the parameter identification problem of determining model parameters from known radionuclide concentrations, is called the inverse problem (IP). In this study, a procedure to solve IP is tested, using the regression technique. Several nonlinear regression programs are examined, and the best one is recommended. 13 refs., 1 tab

  3. Radionuclide Migration at the Rio Blanco Site, A Nuclear-stimulated Low-permeability Natural Gas Reservoir

    Energy Technology Data Exchange (ETDEWEB)

    Clay A. Cooper; Ming Ye; Jenny Chapman; Craig Shirley

    2005-10-01

    The U.S. Department of Energy and its predecessor agencies conducted a program in the 1960s and 1970s that evaluated technology for the nuclear stimulation of low-permeability gas reservoirs. The third and final project in the program, Project Rio Blanco, was conducted in Rio Blanco County, in northwestern Colorado. In this experiment, three 33-kiloton nuclear explosives were simultaneously detonated in a single emplacement well in the Mesaverde Group and Fort Union Formation, at depths of 1,780, 1,899, and 2,039 m below land surface on May 17, 1973. The objective of this work is to estimate lateral distances that tritium released from the detonations may have traveled in the subsurface and evaluate the possible effect of postulated natural-gas development on radionuclide migration. Other radionuclides were considered in the analysis, but the majority occur in relatively immobile forms (such as nuclear melt glass). Of the radionuclides present in the gas phase, tritium dominates in terms of quantity of radioactivity in the long term and contribution to possible whole body exposure. One simulation is performed for {sup 85}Kr, the second most abundant gaseous radionuclide produced after tritium.

  4. Radionuclide therapy of endocrine-related cancer

    International Nuclear Information System (INIS)

    Kratochwil, C.; Giesel, F.L.

    2014-01-01

    This article gives an overview of the established radionuclide therapies for endocrine-related cancer that already have market authorization or are currently under evaluation in clinical trials. Radioiodine therapy is still the gold standard for differentiated iodine-avid thyroid cancer. In patients with bone and lung metastases (near) total remission is seen in approximately 50 % and the 15-year survival rate for these patients is approximately 90 %. In contrast to the USA, meta-iodobenzylguanidine (MIBG) therapy has market approval in Europe. According to the current literature, in the setting of advanced stage neuroblastoma and malignant pheochromocytoma or paraganglioma, radiological remission can be achieved in > 30 % and symptom control in almost 80 % of the treated patients. Somatostatin receptor targeted radionuclide therapies (e.g. with DOTATATE or DOTATOC) demonstrated promising results in phase 2 trials, reporting progression-free survival in the range of 24-36 months. A first phase 3 pivotal trial for intestinal carcinoids is currently recruiting and another trial for pancreatic neuroendocrine tumors is planned. Radiopharmaceuticals based on glucagon-like peptide 1 (GLP1) or minigastrins are in the early evaluation stage for application in the treatment of insulinomas and medullary thyroid cancer. In general, radiopharmaceutical therapy belongs to the group of so-called theranostics which means that therapy is tailored for individual patients based on molecular imaging diagnostics to stratify target positive or target negative tumor phenotypes. (orig.) [de

  5. Quantitative radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function

  6. Radionuclides in thyroid cancer

    International Nuclear Information System (INIS)

    Mahadev, V.

    1980-01-01

    The three main areas of application of radionuclides in thyroid disease will be reviewed. Firstly thyroid radionuclide imaging in thyroid swellings, in relationship to lumps in the neck and ectopic thyroid tissue such as retrosternal goitre, and lingual goitre will be described. Future developments in the field including tomographic scanning, using the coded aperture method, and fluorescent scans and ultrasound are reviewed. The second area of application is the assessment and evaluation of thyroid function and the therapy of Grave's Disease and Plummer's Disease using radioiodine. The importance of careful collection of the line of treatment, results of treatment locally and the follow-up of patients after radioiodine therapy will be described. The third area of application is in the diagnosis and therapy of thyroid cancer. Investigation of thyroid swelling, and the diagnosis of functioning metastases are reported. The therapeutic iodine scan as the sole evidence of functioning metastatic involvement is recorded. Histological thyroid cancer appears to be increasingly encountered in clinical practice and the plan of management in relation to choice of cases for therapeutic scanning is discussed with case reports. Lastly the role of whole body scanning in relationship to biochemical markers is compared. In the changing field of nuclear medicine radionuclide applications in thyroid disease have remained pre-eminent and this is an attempt to reassess its role in the light of newer developments and local experience in the Institute of Radiotherapy, Oncology and Nuclear Medicine. (author)

  7. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  8. Genitourinary imaging

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The application of radionuclide studies in nephrology, urology, and gynecology has reached a measurable degree of maturity in recent years. However, the utilization of these techniques continues to be less frequent than the clinical advantages would seem to warrant, probably because of the complexities of renal physiology. This complexity has been resulted in the availability of large number of agents for renal studies. It is the functional nature of nuclear medicine studies that provides their tremendous potential for use in evaluation of the kidney, where the pathology of which is so often related to functional derangements rather than to anatomic problems. A familiarity with various measures of renal function and with the effects of these parameters on the handling of the commonly used radiopharmaceuticals is essential to the appropriate use of radionuclide studies. The types of studies commonly used include renal perfusion studies, renal imaging solely for anatomic information, and renal imaging combined with an estimate of renal function. Radionuclide techniques serve a complementary role to radiography, ultrasonography, and computed tomography in the morphologic diagnosis of renal diseases. Urethral abnormalities, bladder diverticula, and minimal distal urethral reflux are better demonstrated with radiographic than nuclear technique, but radionuclide cystography can be helpful for follow-up evaluations. Radionuclide testicular imaging is extremely useful in the differential diagnosis of testicular torsion

  9. Analysis of the development of missile-borne IR imaging detecting technologies

    Science.gov (United States)

    Fan, Jinxiang; Wang, Feng

    2017-10-01

    Today's infrared imaging guiding missiles are facing many challenges. With the development of targets' stealth, new-style IR countermeasures and penetrating technologies as well as the complexity of the operational environments, infrared imaging guiding missiles must meet the higher requirements of efficient target detection, capability of anti-interference and anti-jamming and the operational adaptability in complex, dynamic operating environments. Missileborne infrared imaging detecting systems are constrained by practical considerations like cost, size, weight and power (SWaP), and lifecycle requirements. Future-generation infrared imaging guiding missiles need to be resilient to changing operating environments and capable of doing more with fewer resources. Advanced IR imaging detecting and information exploring technologies are the key technologies that affect the future direction of IR imaging guidance missiles. Infrared imaging detecting and information exploring technologies research will support the development of more robust and efficient missile-borne infrared imaging detecting systems. Novelty IR imaging technologies, such as Infrared adaptive spectral imaging, are the key to effectively detect, recognize and track target under the complicated operating and countermeasures environments. Innovative information exploring techniques for the information of target, background and countermeasures provided by the detection system is the base for missile to recognize target and counter interference, jamming and countermeasure. Modular hardware and software development is the enabler for implementing multi-purpose, multi-function solutions. Uncooled IRFPA detectors and High-operating temperature IRFPA detectors as well as commercial-off-the-shelf (COTS) technology will support the implementing of low-cost infrared imaging guiding missiles. In this paper, the current status and features of missile-borne IR imaging detecting technologies are summarized. The key

  10. The use of radiocobalt as a label improves imaging of EGFR using DOTA-conjugated Affibody molecule

    DEFF Research Database (Denmark)

    Garousi, Javad; Andersson, Ken G; Dam, Johan H

    2017-01-01

    -expressing xenografts in mice. An optimal combination of radionuclide, chelator and targeting protein may further improve the contrast of radionuclide imaging. The aim of this study was to evaluate the targeting properties of radiocobalt-labelled DOTA-ZEGFR:2377. DOTA-ZEGFR:2377 was labelled with (57)Co (T1/2 = 271.8 d......), (55)Co (T1/2 = 17.5 h), and, for comparison, with the positron-emitting radionuclide (68)Ga (T1/2 = 67.6 min) with preserved specificity of binding to EGFR-expressing A431 cells. The long-lived cobalt radioisotope (57)Co was used in animal studies. Both (57)Co-DOTA-ZEGFR:2377 and (68)Ga-DOTA......Several anti-cancer therapies target the epidermal growth factor receptor (EGFR). Radionuclide imaging of EGFR expression in tumours may aid in selection of optimal cancer therapy. The (111)In-labelled DOTA-conjugated ZEGFR:2377 Affibody molecule was successfully used for imaging of EGFR...

  11. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  12. Radionuclide behavior at underground environment

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal.

  13. Preparation of porous materials for radionuclides capture

    International Nuclear Information System (INIS)

    Bajzikova, Anna; Smrcek, Stanislav; Kozempel, Jan; Vlk, Martin; Barta, Jan

    2015-01-01

    Porous materials showing promise for radionuclide capture from water at contaminated sites were prepared. Nanoporous materials (size of pores 1-100 nm) and some polymers are well suited to this purpose owing their affinity for selected radionuclides. Nanoporous metal oxides and silica gel with styrene-divinylbenzene-TODGA-modified surface were prepared, characterized and tested for radionuclide ( 227 Ac, 227 Th, 223 Ra) capture efficiency. (orig.)

  14. Intrinsically radiolabelled [(59)Fe]-SPIONs for dual MRI/radionuclide detection.

    Science.gov (United States)

    Hoffman, David; Sun, Minghao; Yang, Likun; McDonagh, Philip R; Corwin, Frank; Sundaresan, Gobalakrishnan; Wang, Li; Vijayaragavan, Vimalan; Thadigiri, Celina; Lamichhane, Narottam; Zweit, Jamal

    2014-01-01

    Towards the development of iron oxide nanoparticles with intrinsically incorporated radionuclides for dual Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and more recently of Single Photon Emission Computed Tomography/Magnetic Resonance Imaging (SPECT/MRI), we have developed intrinsically radiolabeled [(59)Fe]-superparamagnetic iron oxide nanoparticles ([(59)Fe]-SPIONs) as a proof of concept for an intrinsic dual probe strategy. (59)Fe was incorporated into Fe3O4 nanoparticle crystal lattice with 92±3% efficiency in thermal decomposition synthesis. Multidentate poly(acrylic acid)-dopamine-poly(ethylene-glycol-2000) (PAA-DOP-PEG) ligands were designed and synthesized based on facile EDC chemistry and utilized to functionalize the [(59)Fe]-SPIONs. The transverse relaxivity of [(59)Fe]-SPIONs (97±3 s(-1)mM(-1)) was characterized and found to be similar to non-radioactive SPIONs (72±10 s(-1)mM(-1)), indicating that (59)Fe incorporation does not alter the SPIONs' MRI contrast properties. [(59)Fe]-SPIONs were used to evaluate the nanoparticle biodistribution by ex vivo gamma counting and MRI. Nude mice (n=15) were injected with [(59)Fe]-SPIONs and imaged at various time points with 7T small animal MRI scanner. Ex vivo biodistribution was evaluated by tissue-based gamma counting. MRI signal contrast qualitatively correlates with the %ID/g of [(59)Fe]-SPIONs, with high contrast in liver (45±6%), medium contrast in kidneys (21±5%), and low contrast in brain (4±6%) at 24 hours. This work demonstrates the synthesis and in vivo application of intrinsically radiolabeled [(59)Fe]-SPIONs for bimodal detection and provides a proof of concept for incorporation of both gamma- and positron-emitting inorganic radionuclides into the core of metal based MRI contrast agent nanoparticles.

  15. Dosimetric model for antibody targeted radionuclide therapy of tumor cells in cerebrospinal fluid

    International Nuclear Information System (INIS)

    Millar, W.T.; Barrett, A.

    1990-01-01

    Although encouraging results have been obtained using systemic radioimmunotherapy in the treatment of cancer, it is likely that regional applications may prove more effective. One such strategy is the treatment of central nervous system leukemia in children by intrathecal instillation of targeting or nontargeting beta particle emitting radionuclide carriers. The beta particle dosimetry of the spine is assessed, assuming that the spinal cord and the cerebrospinal fluid compartment can be adequately represented by a cylindrical annulus. The radionuclides investigated were 90 Y, 131 I, 67 Cu, and 199 Au. It is shown that the radiation dose to the cord can be significantly reduced using short range beta particle emitters and that there is little advantage in using targeting carriers with these radionuclides. 199 Au and 67 Cu also have the advantage of having a suitable gamma emission for imaging, permitting pretherapy imaging and dosimetric calculations to be undertaken prior to therapy. If these methods prove successful, it may be possible to replace the external beam component used in the treatment of central nervous system leukemia in children by intrathecal radionuclide therapy, thus reducing or avoiding side effects such as growth and intellectual impairment

  16. Advanced digital image archival system using MPEG technologies

    Science.gov (United States)

    Chang, Wo

    2009-08-01

    Digital information and records are vital to the human race regardless of the nationalities and eras in which they were produced. Digital image contents are produced at a rapid pace from cultural heritages via digitalization, scientific and experimental data via high speed imaging sensors, national defense satellite images from governments, medical and healthcare imaging records from hospitals, personal collection of photos from digital cameras. With these mass amounts of precious and irreplaceable data and knowledge, what standards technologies can be applied to preserve and yet provide an interoperable framework for accessing the data across varieties of systems and devices? This paper presents an advanced digital image archival system by applying the international standard of MPEG technologies to preserve digital image content.

  17. Low-level radioactive waste technology: a selected, annotated bibliography

    International Nuclear Information System (INIS)

    Fore, C.S.; Vaughan, N.D.; Hyder, L.K.

    1980-10-01

    This annotated bibliography of 447 references contains scientific, technical, economic, and regulatory information relevant to low-level radioactive waste technology. The bibliography focuses on environmental transport, disposal site, and waste treatment studies. The publication covers both domestic and foreign literature for the period 1952 to 1979. Major chapters selected are Chemical and Physical Aspects; Container Design and Performance; Disposal Site; Environmental Transport; General Studies and Reviews; Geology, Hydrology and Site Resources; Regulatory and Economic Aspects; Transportation Technology; Waste Production; and Waste Treatment. Specialized data fields have been incorporated into the data file to improve the ease and accuracy of locating pertinent references. Specific radionuclides for which data are presented are listed in the Measured Radionuclides field, and specific parameters which affect the migration of these radionuclides are presented in the Measured Parameters field. In addition, each document referenced in this bibliography has been assigned a relevance number to facilitate sorting the documents according to their pertinence to low-level radioactive waste technology. The documents are rated 1, 2, 3, or 4, with 1 indicating direct applicability to low-level radioactive waste technology and 4 indicating that a considerable amount of interpretation is required for the information presented to be applied. The references within each chapter are arranged alphabetically by leading author, corporate affiliation, or title of the document. Indexes are provide for (1) author(s), (2) keywords, (3) subject category, (4) title, (5) geographic location, (6) measured parameters, (7) measured radionuclides, and (8) publication description

  18. Low-level radioactive waste technology: a selected, annotated bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Fore, C.S.; Vaughan, N.D.; Hyder, L.K.

    1980-10-01

    This annotated bibliography of 447 references contains scientific, technical, economic, and regulatory information relevant to low-level radioactive waste technology. The bibliography focuses on environmental transport, disposal site, and waste treatment studies. The publication covers both domestic and foreign literature for the period 1952 to 1979. Major chapters selected are Chemical and Physical Aspects; Container Design and Performance; Disposal Site; Environmental Transport; General Studies and Reviews; Geology, Hydrology and Site Resources; Regulatory and Economic Aspects; Transportation Technology; Waste Production; and Waste Treatment. Specialized data fields have been incorporated into the data file to improve the ease and accuracy of locating pertinent references. Specific radionuclides for which data are presented are listed in the Measured Radionuclides field, and specific parameters which affect the migration of these radionuclides are presented in the Measured Parameters field. In addition, each document referenced in this bibliography has been assigned a relevance number to facilitate sorting the documents according to their pertinence to low-level radioactive waste technology. The documents are rated 1, 2, 3, or 4, with 1 indicating direct applicability to low-level radioactive waste technology and 4 indicating that a considerable amount of interpretation is required for the information presented to be applied. The references within each chapter are arranged alphabetically by leading author, corporate affiliation, or title of the document. Indexes are provide for (1) author(s), (2) keywords, (3) subject category, (4) title, (5) geographic location, (6) measured parameters, (7) measured radionuclides, and (8) publication description.

  19. Research on radionuclide migration under subsurface geochemical conditions. JAERI/AECL Phase II Collaborative Program Year 1 (joint research)

    International Nuclear Information System (INIS)

    1998-11-01

    A radionuclide migration experiment program for fractured rocks was performed under the JAERI/AECL Phase-II Collaborative Program on research and development in radioactive waste management. The program started in the fiscal year 1993, as a five-year program consists of Quarried block radionuclide migration program, Speciation of long-lived radionuclides in groundwater, Isotopic hydrogeology and Groundwater flow model development. During the first year of the program (Program Year 1: March 18, 1994 - September 30, 1994), a plan was developed to take out granite blocks containing part of natural water-bearing fracture from the wall of the experimental gallery at the depth of 240 m, and literature reviews were done in the area of the speciation of long-lived radionuclides in groundwater, isotopic hydrogeology and the groundwater flow model development to proceed further work for the Program Year 2. (author)

  20. Radionuclide Content of Pasteurized Milk Sold in Mafikeng, South Africa

    International Nuclear Information System (INIS)

    Olobatoke, R.; Mathuthu, M.

    2015-01-01

    Many food animals which are important components of human food chain are effective collectors of radionuclides from the environment particularly contaminated forages, and therefore represent a significant pathway for the transfer of radionuclides to humans. Many important radionuclides are readily transferred to milk thus the product is considered as one of the basic food items recommended for the assessment of radionuclide exposure within a population. The current study aimed at assessing the radionuclide content of commercial milk commonly sold in South Africa in other to set a baseline data for radionuclide concentration of the products. Three popular brands of commercial milk (A, B and C) were sampled, with two samples obtained for each brand. The concentration of individual radionuclide in the milk samples, particularly "1"3"1I, "1"3"7Cs and "2"3"5U was measured by gamma spectroscopy. The results showed that brand A had the highest concentrations of "2"3"5U and "1"3"7Cs (203 and 324 mBq/l respectively) but the lowest concentration of "1"3"1I (6.4 mBq/l). The highest concentration of "1"3"1I (148 mBq/l) was detected in brand B whereas both "2"3"5U and "1"3"1I were not detected in brand C. All the values however were well below the new standard limits for individual radionuclides in milk established by the Japanese Ministry of Health, Labour and Welfare. This study indicates that the commercial milk brands assessed pose no radiation health threat to the consumers. (author)

  1. National Low-Level Waste Management Program Radionuclide Report Series

    International Nuclear Information System (INIS)

    Rudin, M.J.; Garcia, R.S.

    1992-02-01

    This volume serves as an introduction to the National Low-Level Radioactive Waste Management Program Radionuclide Report Series. This report includes discussions of radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha-emitting transuranics with half-lives greater than five years). Each report includes information regarding radiological and chemical characteristics of specific radionuclides. Information is also included discussing waste streams and waste forms that may contain each radionuclide, and radionuclide behavior in the environment and in the human body. Not all radionuclides commonly found at low-level radioactive waste sites are included in this report. The discussion in this volume explains the rationale of the radionuclide selection process

  2. Diagnostic radionuclide imaging of amyloid: biological targeting by circulating human serum amyloid P component

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, P.N.; Lavender, J.P.; Myers, M.J.; Pepys, M.B.

    1988-06-25

    The specific molecular affinity of the normal plasma protein, serum amyloid P component (SAP), for all known types of amyloid fibrils was used to develop a new general diagnostic method for in-vivo radionuclide imaging of amyloid deposits. After intravenous injection of /sup 123/I-labelled purified human SAP there was specific uptake into amyloid deposits in all affected patients, 7 with systematic AL amyloid, 5 with AA amyloid, and 2 with ..beta../sub 2/M amyloid, in contrast to the complete absence of any tissue localisation in 5 control subjects. Distinctive high-resolution scintigraphic images, even of minor deposits in the carpal regions, bone marrow, or adrenals, were obtained. This procedure should yield much information on the natural history and the management of amyloidosis, the presence of which has hitherto been confirmed only by biopsy. Clearance and metabolic studies indicated that, in the presence of extensive amyloidosis, the rate of synthesis of SAP was greatly increased despite maintenance of normal plasma levels. Futhermore, once localised to amyloid deposits the /sup 123/I-SAP persisted for long periods and was apparently protected from its normal rapid degradation. These findings shed new light on the pathophysiology of amyloid and may have implications for therapeutic strategies based upon specific molecular targeting with SAP.

  3. Reuse of Material Containing Natural Radionuclides - 12444

    Energy Technology Data Exchange (ETDEWEB)

    Metlyaev, E.G.; Novikova, N.J. [Burnasyan Federal Medical Biophysical Centre, Moscow (Russian Federation)

    2012-07-01

    Disposal of and use of wastes containing natural radioactive material (NORM) or technologically enhanced natural radioactive material (TENORM) with excessive natural background as a building material is very important in the supervision body activity. At the present time, the residents of Octyabrsky village are under resettlement. This village is located just near the Priargunsky mining and chemical combine (Ltd. 'PPGHO'), one of the oldest uranium mines in our country. The vacated wooden houses in the village are demolished and partly used as a building material. To address the issue of potential radiation hazard of the wooden beams originating from demolition of houses in Octyabrsky village, the contents of the natural radionuclides (K-40, Th-232, Ra-226, U- 238) are being determined in samples of the wooden beams of houses. The NORM contents in the wooden house samples are higher, on average, than their content in the reference sample of the fresh wood shavings, but the range of values is rather large. According to the classification of waste containing the natural radionuclides, its evaluation is based on the effective specific activity. At the effective specific activity lower 1.5 kBq/kg and gamma dose rate lower 70 μR/h, the material is not considered as waste and can be used in building by 1 - 3 classes depending upon A{sub eff} value. At 1.5 kBq/kg < A{sub eff} ≤ 4 kBq/kg (4 class), the wooden beams might be used for the purpose of the industrial building, if sum of ratios between the radionuclide specific activity and its specific activity of minimum significance is lower than unit. The material classified as the waste containing the natural radionuclides has A{sub eff} higher 1.5 kBq /kg, and its usage for the purpose of house-building and road construction is forbidden. As for the ash classification and its future usage, such usage is unreasonable, because, according to the provided material, more than 50% of ash samples are considered as

  4. Idaho radionuclide exposure study: Literature review

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.

    1987-10-01

    Phosphate ores contain elevated levels of natural radioactivity, some of which is released to the environment during processing or use of solid byproducts. The effect of radionuclides from Idaho phosphate processing operations on the local communities has been the subject of much research and study. The literature is reviewed in this report. Two primary radionuclide pathways to the environment have been studied in detail: (1) airborne release of volatile radionuclides, primarily 210 Po, from calciner stacks at the two elemental phosphorus plants; and (2) use of byproduct slag as an aggregate for construction in Soda Springs and Pocatello. Despite the research, there is still no clear understanding of the population dose from radionuclide emissions, effluents, and solid wastes from phosphate processing plants. Two other potential radionuclide pathways to the environment have been identified: radon exhalation from phosphogypsum and ore piles and contamination of surface and ground waters. Recommendations on further study needed to develop a data base for a complete risk assssment are given in the report

  5. In vivo quantification of {sup 177}Lu with planar whole-body and SPECT/CT gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Dale L. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Faculty of Health Sciences, University of Sydney, Cumberland, NSW (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Hennessy, Thomas M.; Willowson, Kathy P.; Henry, E. Courtney [Institute of Medical Physics, University of Sydney, Camperdown, NSW (Australia); Chan, David L.H. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Aslani, Alireza [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Roach, Paul J. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia)

    2015-09-17

    Advances in gamma camera technology and the emergence of a number of new theranostic radiopharmaceutical pairings have re-awakened interest in in vivo quantification with single-photon-emitting radionuclides. We have implemented and validated methodology to provide quantitative imaging of {sup 177}Lu for 2D whole-body planar studies and for 3D tomographic imaging with single-photon emission computed tomography (SPECT)/CT. Whole-body planar scans were performed on subjects to whom a known amount of [{sup 177}Lu]-DOTA-octreotate had been administered for therapy. The total radioactivity estimated from the images was compared with the known amount of the radionuclide therapy administered. In separate studies, venous blood samples were withdrawn from subjects after administration of [{sup 177}Lu]-DOTA-octreotate while a SPECT acquisition was in progress and the concentration of the radionuclide in the venous blood sample compared with that estimated from large blood pool structures in the SPECT reconstruction. The total radioactivity contained within an internal SPECT calibration standard was also assessed. In the whole-body planar scans (n = 28), the estimated total body radioactivity was accurate to within +4.6 ± 5.9 % (range −17.1 to +11.2 %) of the correct value. In the SPECT reconstructions (n = 12), the radioactivity concentration in the cardiac blood pool was accurate to within −4.0 ± 7.8 % (range −16.1 to +7.5 %) of the true value and the internal standard measurements (n = 89) were within 2.0 ± 8.5 % (range −16.3 to +24.2 %) of the known amount of radioactivity contained. In our hands, state-of-the-art hybrid SPECT/CT gamma cameras were able to provide accurate estimates of in vivo radioactivity to better than, on average, ±10 % for use in biodistribution and radionuclide dosimetry calculations.

  6. Radionuclide fixation mechanisms in rocks

    International Nuclear Information System (INIS)

    Nakashima, S.

    1991-01-01

    In the safety evaluation of the radioactive waste disposal in geological environment, the mass balance equation for radionuclide migration is given. The sorption of radionuclides by geological formations is conventionally represented by the retardation of the radionuclides as compared with water movement. In order to quantify the sorption of radionuclides by rocks and sediments, the distribution ratio is used. In order to study quantitatively the long term behavior of waste radionuclides in geological environment, besides the distribution ratio concept in short term, slower radionuclide retention reaction involving mineral transformation should be considered. The development of microspectroscopic method for long term reaction path modeling, the behavior of iron during granite and water interaction, the reduction precipitation of radionuclides, radionuclide migration pathways, and the representative scheme of radionuclide migration and fixation in rocks are discussed. (K.I.)

  7. [Identification of green tea brand based on hyperspectra imaging technology].

    Science.gov (United States)

    Zhang, Hai-Liang; Liu, Xiao-Li; Zhu, Feng-Le; He, Yong

    2014-05-01

    Hyperspectral imaging technology was developed to identify different brand famous green tea based on PCA information and image information fusion. First 512 spectral images of six brands of famous green tea in the 380 approximately 1 023 nm wavelength range were collected and principal component analysis (PCA) was performed with the goal of selecting two characteristic bands (545 and 611 nm) that could potentially be used for classification system. Then, 12 gray level co-occurrence matrix (GLCM) features (i. e., mean, covariance, homogeneity, energy, contrast, correlation, entropy, inverse gap, contrast, difference from the second-order and autocorrelation) based on the statistical moment were extracted from each characteristic band image. Finally, integration of the 12 texture features and three PCA spectral characteristics for each green tea sample were extracted as the input of LS-SVM. Experimental results showed that discriminating rate was 100% in the prediction set. The receiver operating characteristic curve (ROC) assessment methods were used to evaluate the LS-SVM classification algorithm. Overall results sufficiently demonstrate that hyperspectral imaging technology can be used to perform classification of green tea.

  8. Beyond the image machine a history of visual technologies

    CERN Document Server

    Tomás, David

    2004-01-01

    Beyond the Image Machine is an eloquent and stimulating argument for an alternative history of scientific and technological imaging systems. Drawing on a range of hitherto and marginalised examples from the world of visual representation and the work of key theorists and thinkers, such as Latour, de Certeau, McLuhan and Barthes, David Tomas offers a disarticulated and deviant view of the relationship between archaic and new representations, imaging technologies and media induced experience. Rejecting the possibility of absolute forms of knowledge, Tomas shows how new media technologies have ch

  9. Application of image processing technology in yarn hairiness detection

    Directory of Open Access Journals (Sweden)

    Guohong ZHANG

    2016-02-01

    Full Text Available Digital image processing technology is one of the new methods for yarn detection, which can realize the digital characterization and objective evaluation of yarn appearance. This paper overviews the current status of development and application of digital image processing technology used for yarn hairiness evaluation, and analyzes and compares the traditional detection methods and this new developed method. Compared with the traditional methods, the image processing technology based method is more objective, fast and accurate, which is the vital development trend of the yarn appearance evaluation.

  10. Medical imaging technology reviews and computational applications

    CERN Document Server

    Dewi, Dyah

    2015-01-01

    This book presents the latest research findings and reviews in the field of medical imaging technology, covering ultrasound diagnostics approaches for detecting osteoarthritis, breast carcinoma and cardiovascular conditions, image guided biopsy and segmentation techniques for detecting lung cancer, image fusion, and simulating fluid flows for cardiovascular applications. It offers a useful guide for students, lecturers and professional researchers in the fields of biomedical engineering and image processing.

  11. Review of spectral imaging technology in biomedical engineering: achievements and challenges.

    Science.gov (United States)

    Li, Qingli; He, Xiaofu; Wang, Yiting; Liu, Hongying; Xu, Dongrong; Guo, Fangmin

    2013-10-01

    Spectral imaging is a technology that integrates conventional imaging and spectroscopy to get both spatial and spectral information from an object. Although this technology was originally developed for remote sensing, it has been extended to the biomedical engineering field as a powerful analytical tool for biological and biomedical research. This review introduces the basics of spectral imaging, imaging methods, current equipment, and recent advances in biomedical applications. The performance and analytical capabilities of spectral imaging systems for biological and biomedical imaging are discussed. In particular, the current achievements and limitations of this technology in biomedical engineering are presented. The benefits and development trends of biomedical spectral imaging are highlighted to provide the reader with an insight into the current technological advances and its potential for biomedical research.

  12. Remediation of Deep Vadose Zone Radionuclide and Metal Contamination: Status and Issues

    Energy Technology Data Exchange (ETDEWEB)

    Dresel, P. Evan; Truex, Michael J.; Cantrell, Keri

    2008-12-30

    This report documents the results of a PNNL literature review to report on the state of maturity of deep vadose zone remediation technologies for metal contaminants including some radionuclides. Its recommendations feed into decisionmakers need for scientific information and cost-effective in situ remediation technlogies needed under DOE's Environmental Management initiative Enhanced Remediation Methods: Scientific & Technical Basis for In Stu Treatment Systems for Metals and Radionuclides.

  13. Emissions of the corrosion radionuclides in an atmosphere

    International Nuclear Information System (INIS)

    Vardanyan, M.

    2010-01-01

    In area of Armenian nuclear power plant location, in atmospheric air in majority of cases log two technogenic radionuclides: l 37 C s and 9 0 S r. Presence of these radionuclides basically is caused by global fall out (consequences of tests of the nuclear weapon and Chernobyl NPP accident), whose contribution to the contents of these radionuclides in atmosphere is incomparably greater, than emissions from the NPP. However there are some cases when in an atmosphere are registered the technogenic radionuclides, caused by emissions from NPP. In the present work such case is considered. Gas-aerosol releases of NPP in the atmosphere are carefully purified by means of various high-efficiency filters and gas-cleaning systems. Nevertheless, one should forecast and measure, the possible impact of these releases on the environment in the regions surrounding the NPP. Radioactive releases of the Armenian NPP (ANPP) contain the set of radionuclides characteristic for NPPs of this type. They may be divided into three groups: 1 31 I , 1 37 C s, 1 34 C s, 9 0 S r and 8 9 S r fission fragments, isotopes of noble gases krypton and xenon and other radionuclides; corrosion originated radionuclides: 6 0 C o, 1 10m A g, 5 4 M n, 5 l C r and others; activation products of the heat-transfer agent itself. It should be noted that the amount of radioactive materials released in the environment by the ANPP during the whole period of its operation was much lower than the admissible quantities specified in the corresponding legal documents (RSN, NPPSP) acting in Armenia, which are practically identical to the internationally accepted norms. The amounts of releases and their radionuclides composition for the ANPP are given

  14. WE-DE-201-06: Impact of Temporal Image Coregistration Methods On 3D Internal Dose Calculations in Targeted Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Besemer, A; Marsh, I; Bednarz, B [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: The calculation of 3D internal dose calculations in targeted radionuclide therapy requires the acquisition and temporal coregistration of a serial PET/CT or SPECT/CT images. This work investigates the dosimetric impact of different temporal coregistration methods commonly used for 3D internal dosimetry. Methods: PET/CT images of four mice were acquired at 1, 24, 48, 72, 96, 144 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose rate (ADR) was calculated at each time point using a Geant4-based MC dosimetry platform using three temporal image coregistration Methods: (1) no coregistration (NC), whole body sequential CT-CT affine coregistration (WBAC), and individual sequential ROI-ROI affine coregistration (IRAC). For NC, only the ROI mean ADR was integrated to obtain ROI mean doses. For WBAC, the CT at each time point was coregistered to a single reference CT. The CT transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the whole CT volume. For IRAC, each individual ROI was isolated and sequentially coregistered to a single reference ROI. The ROI transformations were applied to the corresponding ADR images and the dose was calculated on a voxel-basis within the ROI volumes. Results: The percent differences in the ROI mean doses were as large as 109%, 88%, and 32%, comparing the WBAC vs. IRAC, NC vs. IRAC, and NC vs. WBAC methods, respectively. The CoV in the mean dose between the all three methods ranged from 2–36%. The pronounced curvature of the spinal cord was not adequately coregistered using WBAC which resulted in large difference between the WBAC and IRAC. Conclusion: The method used for temporal image coregistration can result in large differences in 3D internal dosimetry calculations. Care must be taken to choose the most appropriate method depending on the imaging conditions, clinical site, and specific application. This work is partially funded by

  15. Review of speciation and solubility of radionuclides in the near and far field. Pt. 1

    International Nuclear Information System (INIS)

    Smith-Briggs, J.L.

    1992-01-01

    This report represents Part 1 in a series of three reports which review the speciation and solubility of radionuclides in the near and far field. Part 1 reviews the research funded by UK Nirex Ltd (NIREX) and the Department of the Environment into the solubility and speciation of radionuclides in the near and far fields of a radioactive waste repository. The review is focused on the particular situation prevailing in the UK. UK Nirex Limited are currently planning the development of a deep geological repository for low and intermediate level wastes. In the basic design it is envisaged that the waste material would be immobilised and packed into steel or concrete containers. These containers would be placed in vaults and then backfilled with a cemetitious grout. (Author)

  16. Development of the 1.2 T~1.5 T Permanent Magnetic Resonance Imaging Device and Its Application for Mouse Imaging

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2015-01-01

    Full Text Available By improving the main magnet, gradient, and RF coils design technology, manufacturing methods, and inventing new magnetic resonance imaging (MRI special alloy, a cost-effective and small animal specific permanent magnet-type three-dimensional magnetic resonance imager was developed. The main magnetic field strength of magnetic resonance imager with independent intellectual property rights is 1.2~1.5 T. To demonstrate its effectiveness and validate the mouse imaging experiments in different directions, we compared the images obtained by small animal specific permanent magnet-type three-dimensional magnetic resonance imager with that obtained by using superconductor magnetic resonance imager for clinical diagnosis.

  17. Plant phenomics: an overview of image acquisition technologies and image data analysis algorithms.

    Science.gov (United States)

    Perez-Sanz, Fernando; Navarro, Pedro J; Egea-Cortines, Marcos

    2017-11-01

    The study of phenomes or phenomics has been a central part of biology. The field of automatic phenotype acquisition technologies based on images has seen an important advance in the last years. As with other high-throughput technologies, it addresses a common set of problems, including data acquisition and analysis. In this review, we give an overview of the main systems developed to acquire images. We give an in-depth analysis of image processing with its major issues and the algorithms that are being used or emerging as useful to obtain data out of images in an automatic fashion. © The Author 2017. Published by Oxford University Press.

  18. Marine biogeochemistry of radionuclides

    International Nuclear Information System (INIS)

    Fowler, S.W.

    1997-01-01

    Radionuclides entering the ocean from runoff, fallout, or deliberate release rapidly become involved in marine biogeochemical cycles. Sources, sinks and transport of radionuclides and analogue elements are discussed with emphasis placed on how these elements interact with marine organisms. Water, food and sediments are the source terms from which marine biota acquire radionuclides. Uptake from water occurs by surface adsorption, absorption across body surfaces, or a combination of both. Radionuclides ingested with food are either assimilated into tissue or excreted. The relative importance of the food and water pathway in uptake varies with the radionuclide and the conditions under which exposure occurs. Evidence suggests that, compared to the water and food pathways, bioavailability of sediment-bound radionuclides is low. Bioaccumulation processes are controlled by many environmental and intrinsic factors including exposure time, physical-chemical form of the radionuclide, salinity, temperature, competitive effects with other elements, organism size, physiology, life cycle and feeding habits. Once accumulated, radionuclides are transported actively by vertical and horizontal movements of organisms and passively by release of biogenic products, e.g., soluble excreta, feces, molts and eggs. Through feeding activities, particles containing radionuclides are ''packaged'' into larger aggregates which are redistributed upon release. Most radionuclides are not irreversibly bound to such particles but are remineralized as they sink and/or decompose. In the pelagic zones, sinking aggregates can further scavenge particle-reactive elements thus removing them from the surface layers and transporting them to depth. Evidence from both radiotracer experiments and in situ sediment trap studies is presented which illustrates the importance of biological scavenging in controlling the distribution of radionuclides in the water column. (author)

  19. Monitoring of processes with gamma-rays of neutron capture and short-living radionuclides

    International Nuclear Information System (INIS)

    Aripov, G.A.; Kurbanov, B.I.; Allamuratova, G.

    2004-01-01

    Element content is a fundamental parameter of a substance, on which all its properties, and also character of physical, chemical, biological, technological and ecological processes depend. Therefore monitoring of element content (in the course of technological process - on line; in natural conditions - in site; or in living organisms - in vivo) becomes necessary for investigation of aforementioned processes. This problem can be successfully solved by using the methods of prompt gamma activation analysis (PGAA) and instrumental neutron activation analysis (INAA) on short-living radionuclides. These methods don't depend on type of substance (biological, geological, technological etc.), since the content is determined by gamma radiation of nuclei, and allows to meet such a serious requirement like the necessity of achieving minimal irradiation of the object and its minimal residual activity. In this work minimal determinable concentrations of various elements are estimated (based on experimental data) by the method of PGAA using radionuclide 252 Cf - source of neutrons with the yield of the oil of 10 8 neutron/sec on the experimental device with preliminary focusing of neutrons /1/, and also data of determination of elements by their isotopes with maximum time efficiency /2,3/ by the method of INAA. (author)

  20. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Bovaird, Chase C.; Jansik, Danielle P.; Wellman, Dawn M.; Wood, Marcus I.

    2011-09-30

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. The information present in the report provides data that (1) measures the effect of concrete wasteform properties likely to influence radionuclide migration; and (2) quantifies the rate of carbonation of concrete materials in a simulated vadose zone repository.

  1. Radionuclide characterization of environmental air around nuclear facilities

    International Nuclear Information System (INIS)

    Gede Sutresna Wijaya; Anung Muharini

    2015-01-01

    Air is an important environmental component in human life. Presence of air pollutants or contaminants will have a negative impact on human health. According to the existence of a nuclear facility in Yogyakarta, the characterization of radionuclides in the air is absolutely necessary to ensure the safety of people and the environment and also to supervise the safe operation of the facility. In this research the characterization of radionuclides in the air was carried through the air sampling by using High Volume Air Sampler equipped with filter TFA 2133, followed by analysis using combination of a gamma and alpha spectrometers. The concentration of radioactivity in the air fluctuates depending on the time and duration of sampling. Characterization of gamma emitting radionuclides in the air is dominated by radon progeny radionuclides such as 214 Pb, 214 Bi with activity 20.09 ± 1.23 until 32.91 ± 4.87 Bq/m 3 and 31.22 ± 1.76 until 44.25 ± 4.91 Bq/m 3 . Alpha emitter radionuclide was dominated by 214 Po (7.69 MeV) which is also radon progeny and a primordial radionuclides. It can be concluded that the presence of radionuclides in the environmental air not as a product resulting from the operation of nuclear facilities in Yogyakarta. (author)

  2. Concentration of some radionuclides in Moringa Oliefera plant

    International Nuclear Information System (INIS)

    Abd elbagi, W. K. A.

    2013-07-01

    This study has been conducted to determine the radioactivity concentration of naturally occurring radionuclides 228 U, 232 Th, and 40 K in samples of Moringaoliefera plants in Khartoum Bahry Elsamrab by using γ ray spectrometry sodium iodide detector and high purity germanium detector. A total of 30 samples, 10 samples from leaves, 10 samples from seeds and 10 samples from soil of samples have been collected. For leaves the radionuclide activity concentrations in samples analyzed with the mean of 2767.266±78.6741 Bq kg - 1 for 238 U, 3486.817±80.98811 Bq kg - 1 for 238 Th and 2273.386±54.152 Bq kg - 1 for 40 K. For seeds the radionuclide activity concentration in samples analyzed with the mean of 2839.224±72.6016 Bq kg - 1 for 238 U, 2844.372±78.74919 Bq kg - 1 for 2 38T h and 2377.005±91.8838 Bq kg - 1 for 40 K. No trace of artificial radionuclide has been determined in all the samples. The effective dose due to the presence of these radionuclides has been estimated and found 0.89μSv/year and 0.1015μSv/year for 232 Th, 238 U and 40 K, respectively.(Author)

  3. Report on the 1. research coordination meeting on 'Development of therapeutic radiopharmaceuticals based on 177Lu for radionuclide therapy'

    International Nuclear Information System (INIS)

    2006-01-01

    Radionuclide therapy (RNT) employing radiopharmaceuticals labelled with emitting radionuclides is fast emerging as an important part of nuclear medicine. Radionuclide therapy is effectively utilized for bone pain palliation, thus providing significant improvement in quality of life of patients suffering from pain resulting from bone metastasis. Targeting primary diseases by using specific carrier molecules labelled with radionuclides is also widely investigated and efficacious products have been emerging for the treatment of Lymphoma and Neuroendocrine tumours. In order to ensure the wider use of radiopharmaceuticals, it is essential to carefully consider the choice of radionuclides that together with the carrier molecules will give suitable pharmacokinetic properties and therapeutic efficacy. The criteria for the selection of a radionuclide for radiotherapy are suitable decay characteristics and amenable chemistry. However, the practical considerations in selecting a radionuclide for targeted therapy are availability in high radionuclidic purity as well as high specific activity and low production cost and comfortable delivery logistics. 177 Lu is one of the isotopes emerging as a clear choice for therapy. Worldwide, the isotope is under investigation for approximately 30 different clinical applications, including treatment of colon cancer, metastatic bone cancer, non-Hodgkin's lymphoma, and lung cancer. 177 Lu decays with a half-life of 6.71 d by emission of particles with E max of 497 keV (78.6%), 384 keV (9.1%) and 176 keV (12.2%). It also emits photons of 113 keV (6.4%) and 208 keV (11%), that are ideally suited for imaging the in-vivo localization and dosimetric calculations applying a gamma camera. The physical half-life of 177 Lu is comparable to that of 131 I, the most widely used therapeutic radionuclide. The long halflife of 177 Lu provides logistic advantage for production, QA/QC of the products as well as feasibility to supply the products to places

  4. Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology

    Energy Technology Data Exchange (ETDEWEB)

    Spink, C., E-mail: c.spink@uke.de [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Avanesov, M. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Schmidt, T. [Philips Healthcare, Hamburg (Germany); Grass, M. [Philips Research, Hamburg (Germany); Schoen, G. [Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Adam, G.; Bannas, P.; Koops, A. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2017-01-15

    Highlights: • The new imaging technology halved the radiation exposure. • DSA image quality observed was not decreased after technology upgrade. • Radiation time and contrast consumption not significantly increased using the new technology. - Abstract: Objective: To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade. Methods: In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test. Results: The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3 Gycm{sup 2}, p < 0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7 Gy, p < 0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8 min, p = 0.45) and amount of contrast agent (109.4 vs. 114.9 ml, p = 0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p = 0.56). Conclusions: In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.

  5. Review of research on sonar imaging technology in China

    Science.gov (United States)

    Guo, Haitao; Li, Renping; Xu, Feng; Liu, Liyuan

    2013-11-01

    Over the past 20 years, sonar imaging technology particularly for the high-technology sector has been a focus of research, in which many developed countries, especially those with coast lines, have been competing with each other. It has seen a rapid development with increasing widespread applications that has played an important and irreplaceable role in underwater exploration with great prospects for social, economic, scientific, and military benefits. The fundamental techniques underlying sonar imaging, including multi-beamforming, synthetic-aperture and inverse synthetic-aperture sonar, acoustic lensing, and acoustical holography, are described in this paper. This is followed by a comprehensive and systematic review on the advantages and disadvantages of these imaging techniques, applicability conditions, development trends, new ideas, new methods, and improvements in old methods over recent years with an emphasis on the situation in China, along with a bold and constructive prediction to some development characteristics of sonar imaging technology in the near future in China. The perspectives presented in this paper are offered with the idea of providing some degree of guidance and promotion of research on sonar imaging technology.

  6. Radiation-Induced Second Cancer Risk Estimates From Radionuclide Therapy

    Science.gov (United States)

    Bednarz, Bryan; Besemer, Abigail

    2017-09-01

    The use of radionuclide therapy in the clinical setting is expected to increase significantly over the next decade. There is an important need to understand the radiation-induced second cancer risk associated with these procedures. In this study the radiation-induced cancer risk in five radionuclide therapy patients was investigated. These patients underwent serial SPECT imaging scans following injection as part of a clinical trial testing the efficacy of a 131Iodine-labeled radiopharmaceutical. Using these datasets the committed absorbed doses to multiple sensitive structures were calculated using RAPID, which is a novel Monte Carlo-based 3D dosimetry platform developed for personalized dosimetry. The excess relative risk (ERR) for radiation-induced cancer in these structures was then derived from these dose estimates following the recommendations set forth in the BEIR VII report. The radiation-induced leukemia ERR was highest among all sites considered reaching a maximum value of approximately 4.5. The radiation-induced cancer risk in the kidneys, liver and spleen ranged between 0.3 and 1.3. The lifetime attributable risks (LARs) were also calculated, which ranged from 30 to 1700 cancers per 100,000 persons and were highest for leukemia and the liver for both males and females followed by radiation-induced spleen and kidney cancer. The risks associated with radionuclide therapy are similar to the risk associated with external beam radiation therapy.

  7. Radionuclide transfer

    International Nuclear Information System (INIS)

    Gerber, G.B.

    1993-01-01

    The research project described here had the aim to obtain further information on the transfer of nuclides during pregnancy and lactation. The tests were carried out in mini-pigs and rats receiving unchanging doses of radionuclides with the food. The following findings were revealed for the elements examined: Fe, Se, Cs and Zn were characterized by very high transfer levels in the mother, infant and foetus. A substantial uptake by the mother alone was observed for Co, Ag and Mn. The uptake by the foetus and infant here was 1 to 10 times lower. A preferential concentration in certain tissues was seen for Sr and Tc; the thyroid levels of Tc were about equally high in mothers and infants, while Sr showed less accumulation in the maternal bone. The lanthanide group of substances (Ce, Eu and Gd as well as Y and Ru) were only taken up to a very limited extent. The uptake of the examined radionuclides (Fe, Co, Ag, Ce) with the food ingested was found here to be ten times greater in rats as compared to mini-pigs. This showed that great caution must be observed, if the behaviour of radionuclides in man is extrapolated from relevant data obtained in rodents. (orig./MG) [de

  8. The paradox of imaging technology: A review of the literature

    International Nuclear Information System (INIS)

    Murphy, F.J.

    2006-01-01

    Purpose: The purpose of this study was to review the social scientific literature associated with medical imaging technology. Methods: An extensive search of published studies in nursing, psychology and anthropology was undertaken to support the radiography specific literature. Results: Following a broad definition of technology and its profound influence on society, an analysis of imaging literature revealed a complex relationship between technology and human interactions. Examples are cited for CT, MRI and ultrasound. Conclusion: It is suggested that any attempt to understand imaging technology must place at its centre the perspectives of patients and radiographers. Scientific descriptors must be balanced with equal deliberation given to 'soft technology'

  9. Influence of break structures on the distribution of radionuclides in bottom sediments of the Kyiv reservoir

    International Nuclear Information System (INIS)

    Shestopalov, V.M.; Lyal'ko, V.I.; Fedorovskij, A.D.; Sirenko, L.A.; Khodorovskij, A.Ya.

    2000-01-01

    We study the distribution of radionuclides in bottom sediments of the Kyiv reservoir on the basis of research of adjacent territory break - block structures with deciphering space-born images and ground measurements and forecast the occurrence of extreme situations due to the redistribution of bottom water flows and sediments of radionuclides

  10. Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

    Science.gov (United States)

    Walsworth, Ronald L.

    2004-01-01

    We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

  11. Uptake by plants of radionuclides from FUSRAP waste materials

    International Nuclear Information System (INIS)

    Knight, M.J.

    1983-04-01

    Radionuclides from FUSRAP wastes potentially may be taken up by plants during remedial action activities and permanent near-surface burial of contaminated materials. In order to better understand the propensity of radionuclides to accumulate in plant tissue, soil and plant factors influencing the uptake and accumulation of radionuclides by plants are reviewed. In addition, data describing the uptake of the principal radionuclides present in FUSRAP wastes (uranium-238, thorium-230, radium-226, lead-210, and polonium-210) are summarized. All five radionuclides can accumulate in plant root tissue to some extent, and there is potential for the translocation and accumulation of these radionuclides in plant shoot tissue. Of these five radionuclides, radium-226 appears to have the greatest potential for translocation and accumulation in plant shoot tissue. 28 references, 1 figure, 3 tables

  12. Uptake by plants of radionuclides from FUSRAP waste materials

    Energy Technology Data Exchange (ETDEWEB)

    Knight, M.J.

    1983-04-01

    Radionuclides from FUSRAP wastes potentially may be taken up by plants during remedial action activities and permanent near-surface burial of contaminated materials. In order to better understand the propensity of radionuclides to accumulate in plant tissue, soil and plant factors influencing the uptake and accumulation of radionuclides by plants are reviewed. In addition, data describing the uptake of the principal radionuclides present in FUSRAP wastes (uranium-238, thorium-230, radium-226, lead-210, and polonium-210) are summarized. All five radionuclides can accumulate in plant root tissue to some extent, and there is potential for the translocation and accumulation of these radionuclides in plant shoot tissue. Of these five radionuclides, radium-226 appears to have the greatest potential for translocation and accumulation in plant shoot tissue. 28 references, 1 figure, 3 tables.

  13. Radionuclide evaluation of brain death

    International Nuclear Information System (INIS)

    Pjura, G.A.; Kim, E.E.

    1987-01-01

    The criteria employed for clinical determination of death have evolved in response to advances in life support and other medical technology. The technical feasibility of organ transplantation has amplified the need for a definition of brain death that can be applied in the shortest possible time in the presence of artificial maintenance of vegetative functions, including circulation. Radionuclide cerebral angiography is one of a group of diagnostic procedures that can be employed to confirm the clinical diagnosis of brain death through demonstration of absence of cerebral blood flow. The focus of this work is to assess its use as a confirmatory test for determination of brain death in the context of currently available alternative technologies

  14. Image processing technology for nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Beom; Kim, Woong Ki; Park, Soon Young

    1993-05-01

    Digital image processing technique is being actively studied since microprocessors and semiconductor memory devices have been developed in 1960's. Now image processing board for personal computer as well as image processing system for workstation is developed and widely applied to medical science, military, remote inspection, and nuclear industry. Image processing technology which provides computer system with vision ability not only recognizes nonobvious information but processes large information and therefore this technique is applied to various fields like remote measurement, object recognition and decision in adverse environment, and analysis of X-ray penetration image in nuclear facilities. In this report, various applications of image processing to nuclear facilities are examined, and image processing techniques are also analysed with the view of proposing the ideas for future applications. (Author)

  15. Nuclear medicine imaging in podiatric disorders

    International Nuclear Information System (INIS)

    Karl, R.D. Jr.; Hammes, C.S.

    1988-01-01

    Radionuclide scanning is a valuable diagnostic tool based on metabolic and anatomic imaging. When used in the appropriate clinical setting, radionuclide imaging is a sensitive, minimally invasive imaging modality that detects and differentiates skeletal from nonskeletal pathology in the painful foot. Isotopic scanning is of particular value in the evaluation of the diabetic foot and in the subsequent follow-up of response to therapy.72 references

  16. The use of radionuclide skeleton visualization method in hygienic studies

    International Nuclear Information System (INIS)

    Likutova, I.V.; Bobkova, T.E.; Belova, E.A.; Bogomazov, M.Ya.

    1984-01-01

    Inhalation, intragastric and combined effect of two cadmium compounds on rats is studied. Investigations are performed by biochemical methods and the method of radionuclide visualization of the skeleton which was performed delta hours after RPP introduction in gamma-chamber with computer tape recording for the following mathematical treatment of the image. Using the method of radionuclide skeleton visualization pronounced quantitative characteristics of changes in the bone tissue are obtained, it is found that dose dependence of these changes is especially important when estimating the complex effect. Biochemical methods, are used to find alterations, however they have not been assessed quantitatively

  17. The development of application technology for image processing in nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Bum; Kim, Woog Ki; Sohn, Surg Won; Kim, Seung Ho; Hwang, Suk Yeoung; Kim, Byung Soo

    1991-01-01

    The object of this project is to develop application technology of image processing in nuclear facilities where image signal are used for reliability and safety enhancement of operation, radiation exposure reduce of operator, and automation of operation processing. We has studied such application technology for image processing in nuclear facilities as non-tactile measurement, remote and automatic inspection, remote control, and enhanced analysis of visual information. On these bases, automation system and real-time image processing system are developed. Nuclear power consists in over 50% share of electic power supply of our country nowdays. So, it is required of technological support for top-notch technology in nuclear industry and its related fields. Especially, it is indispensable for image processing technology to enhance the reliabilty and safety of operation, to automate the process in a place like a nuclear power plant and radioactive envionment. It is important that image processing technology is linked to a nuclear engineering, and enhance the reliability abd safety of nuclear operation, as well as decrease the dose rate. (Author)

  18. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    Schreiner, R.

    2001-01-01

    The purpose of this work is to develop the Engineered Barrier System (EBS) radionuclide transport abstraction model, as directed by a written development plan (CRWMS M and O 1999a). This abstraction is the conceptual model that will be used to determine the rate of release of radionuclides from the EBS to the unsaturated zone (UZ) in the total system performance assessment-license application (TSPA-LA). In particular, this model will be used to quantify the time-dependent radionuclide releases from a failed waste package (WP) and their subsequent transport through the EBS to the emplacement drift wall/UZ interface. The development of this conceptual model will allow Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department to provide a more detailed and complete EBS flow and transport abstraction. The results from this conceptual model will allow PA0 to address portions of the key technical issues (KTIs) presented in three NRC Issue Resolution Status Reports (IRSRs): (1) the Evolution of the Near-Field Environment (ENFE), Revision 2 (NRC 1999a), (2) the Container Life and Source Term (CLST), Revision 2 (NRC 1999b), and (3) the Thermal Effects on Flow (TEF), Revision 1 (NRC 1998). The conceptual model for flow and transport in the EBS will be referred to as the ''EBS RT Abstraction'' in this analysis/modeling report (AMR). The scope of this abstraction and report is limited to flow and transport processes. More specifically, this AMR does not discuss elements of the TSPA-SR and TSPA-LA that relate to the EBS but are discussed in other AMRs. These elements include corrosion processes, radionuclide solubility limits, waste form dissolution rates and concentrations of colloidal particles that are generally represented as boundary conditions or input parameters for the EBS RT Abstraction. In effect, this AMR provides the algorithms for transporting radionuclides using the flow geometry and radionuclide concentrations determined by other

  19. Medical Imaging.

    Science.gov (United States)

    Barker, M. C. J.

    1996-01-01

    Discusses four main types of medical imaging (x-ray, radionuclide, ultrasound, and magnetic resonance) and considers their relative merits. Describes important recent and possible future developments in image processing. (Author/MKR)

  20. Radionuclide Air Emissions Report for 2012

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Linnea [Ernest Orlando Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2013-05-01

    Berkeley Lab operates facilities where radionuclides are produced, handled, store d, and potentially emitted . These facilities are subject to the EPA radioactive air emission regulations in 40 CFR 61, Subpart H (EPA 1989a). Radionuclides may be emitted from stacks or vents on buildings where radionuclide production or use is authorized or they may be emitted as diffuse sources. In 2012, all Berkeley Lab sources were minor sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]) . These minor sources include d about 140 stack sources and no diffuse sources . T here were no unplanned airborne radionuclide emissions from Berkeley Lab operations . Emissions from minor sources were measured by sampling or monitoring or were calculated based on quantities used, received for use, or produced during the year. Using measured and calculated emissions, and building- specific and common parameters, Laboratory personnel applied the EPA -approved computer code s, CAP88-PC and COMPLY , to calculate doses to the maximally exposed individual (MEI) at any offsite point where there is a residence, school, business, or office. Because radionuclides are used at three noncontiguous locations (the main site, Berkeley West Bio center, and Joint BioEnergy Institute), three different MEIs were identified.

  1. Radionuclide Retention in Concrete Waste Forms

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Bovaird, Chase C.; Wellman, Dawn M.; Wood, Marcus I.

    2010-09-30

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how waste form performance is affected by the full range of environmental conditions within the disposal facility; the process of waste form aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of waste form aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the waste forms come in contact with groundwater. The information presented in the report provides data that 1) quantify radionuclide retention within concrete waste form materials similar to those used to encapsulate waste in the Low-Level Waste Burial Grounds (LLBG); 2) measure the effect of concrete waste form properties likely to influence radionuclide migration; and 3) quantify the stability of uranium-bearing solid phases of limited solubility in concrete.

  2. Future of X-ray phase imaging in medical imaging technology

    International Nuclear Information System (INIS)

    Momose, Atsushi

    2007-01-01

    Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

  3. Nuclear medicine and quantitative imaging research (quantitative studies in radiopharmaceutical science): Comprehensive progress report, April 1, 1986-December 31, 1988

    International Nuclear Information System (INIS)

    Cooper, M.D.; Beck, R.N.

    1988-06-01

    This document describes several years research to improve PET imaging and diagnostic techniques in man. This program addresses the problems involving the basic science and technology underlying the physical and conceptual tools of radioactive tracer methodology as they relate to the measurement of structural and functional parameters of physiologic importance in health and disease. The principal tool is quantitative radionuclide imaging. The overall objective of this program is to further the development and transfer of radiotracer methodology from basic theory to routine clinical practice in order that individual patients and society as a whole will receive the maximum net benefit from the new knowledge gained. The focus of the research is on the development of new instruments and radiopharmaceuticals, and the evaluation of these through the phase of clinical feasibility. The reports in the study were processed separately for the data bases

  4. Environmental radioactivity in Caithness and Sutherland. Pt. 1: Food-chain model validation and the attribution of radionuclide sources to deposition

    International Nuclear Information System (INIS)

    Rose, C.L.; Halliwell, C.M.

    1995-01-01

    This study is part of a continuing programme investigating the behaviour of environmental radioactivity in the vicinity of the AEA Technology establishment at Dounreay, Caithness and Sutherland. The study aims were to assess the applicability of a National Radiological Protection Board (NRPB) food-chain model to the Caithness and Sutherland area, and to determine the contribution of different radionuclide sources to activities in measured total deposition in the same region. The NRPB model predicts the movement of radionuclides through the food-chain, and in this study was validated by comparing model outputs with measured crop data (ryegrass and clover). Five radionuclides ( 137 Cs, 90 Sr, 239+240 Pu, 238 Pu, 241 Am) were considered. The contribution of different radionuclide sources to activities in total deposition were divided into three categories: Dounreay stack inputs, sea-to-land transfer, and the combined contribution from nuclear weapons testing and Chernobyl fallout. The analyses indicated that the contribution of the Dounreay stack to total deposition was very small for the radionuclides studied. The Chernobyl accident made a large impact on the total deposition of 137 Cs in the study area, and 90 Sr deposition was also affected by this, but to a much lesser extent. The Chernobyl accident appeared to have no effect on total Pu deposition in the region. The cessation of nuclear weapons testing and the length of time since Chernobyl meant that actual 137 Cs and 90 Sr deposition as a result of weapons/Chernobyl inputs had reached a low level by the end of the study period (summer 1987). It became evident that a contribution to total deposition was being made by additional factors, thought to be local resuspension of large particles for 137 Cs, and possibly deposition of plant material for 90 Sr. For Pu, sea-to-land transfer was probably an important contributor at coastal sites. (Author)

  5. Intrinsically radiolabelled [59Fe]-SPIONs for dual MRI/radionuclide detection

    OpenAIRE

    Hoffman, David; Sun, Minghao; Yang, Likun; McDonagh, Philip R; Corwin, Frank; Sundaresan, Gobalakrishnan; Wang, Li; Vijayaragavan, Vimalan; Thadigiri, Celina; Lamichhane, Narottam; Zweit, Jamal

    2014-01-01

    Towards the development of iron oxide nanoparticles with intrinsically incorporated radionuclides for dual Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and more recently of Single Photon Emission Computed Tomography/Magnetic Resonance Imaging (SPECT/MRI), we have developed intrinsically radiolabeled [59Fe]-superparamagnetic iron oxide nanoparticles ([59Fe]-SPIONs) as a proof of concept for an intrinsic dual probe strategy. 59Fe was incorporated into Fe3O4 nanoparticle cry...

  6. The National Medical Cyclotron - An Australian experience in technology

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, R K [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). National Medical Cyclotron

    1998-12-31

    The establishment of the National Medical Cyclotron (NMC) in the early 1990`s was the practical outcome of a vision, held by nuclear medicine professionals, to complement the available neutron-rich radionuclides produced in Australia, with neutron-deficient radionuclides. The NMC is operated by the Australian Nuclear Science and Technology Organisation (ANSTO) in collaboration with the Royal Prince Alfred Hospital (RPAH) in Sydney where the PET department is able to use the short-lived radiotracers to good advantage. Neutron-deficient radionuclides, are also produced by the NMC laboratories. The cyclotron-generated radionuclides are used in over 70,000 patient studies per year. 7 refs., 1 tab.

  7. Radionuclides in marine organisms

    International Nuclear Information System (INIS)

    Honda, Teruyuki

    2001-01-01

    The concentration and accumulation of radionuclides in marine organisms were explained in this paper. Secular change of the radioactivity concentration of 137 Cs in seaweed in coastal area of Japan showed more than 5Bq/kg-fresh in the first half of 1960, but decreased less than 1 Bq/kg-fresh after then and attained to less than 0.1 Bq/kg-fresh in 1990s. However, the value increased a while in 1986, which indicated the effect of Chernobyl accident. The accident increased 137 Cs of shellfish near Japan. The concentration of 239+240 Pu was the lowest value in muscles of fish, but increased from 1.7 to 42.3 mBq/kg wet wt in seaweed in 1999. 99 Tc concentration of seaweed showed from 100 to 1000 times as much as that of seawater. Radionuclides in the Irish Sea are originated from Sellafield reprocessing plant. The concentration factors of macro-algae and surface water fish (IAEA,1985) were shown. Analytical results of U in 61 kinds of marine organs showed that the concentration was different in the part of organ. The higher concentration of U was observed in hard tissue of fish. The concentration factor was different between chemical substances with the same radionuclides. (S.Y.)

  8. Excretion of radionuclides in human breast milk after nuclear medicine examinations. Biokinetic and dosimetric data and recommendations on breastfeeding interruption

    Energy Technology Data Exchange (ETDEWEB)

    Liepe, K. [GH Hospital Frankfurt/Oder, Department of Nuclear Medicine, Frankfurt an der Oder (Germany); Becker, A. [GH Hospital Frankfurt/Oder, Department of Internal Medicine, Frankfurt an der Oder (Germany)

    2016-05-15

    Since the 1990s the advantages of breastfeeding have been emphasized and the number of women who nurse their infant has increased significantly. Although women in this population are generally healthy and relatively rarely need radionuclide imaging or radionuclide therapies, the issue of radiation protection of breastfed children arises because of their higher radiosensitivity. Approximately 55 papers on excretion of radionuclides in human breast milk after radionuclide imaging or therapy have been published. Unfortunately, most of them are case reports or include only a small number of cases. In 1955 the first report was published about a breastfeeding woman after radioiodine treatment of thyrotoxicosis. This early study showed a higher concentration of radioiodine in breast milk than in plasma and investigated the risk to the infant, especially to the thyroid gland.

  9. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Allen, S.E.; Horrill, A.D.; Howard, B.J.; Lowe, V.P.W.; Parkinson, J.A.

    1983-07-01

    The subject is discussed under the headings: concentration and spatial distribution of radionuclides in grazed and ungrazed saltmarshes; incorporation of radionuclides by sheep grazing on an estuarine saltmarsh; inland transfer of radionuclides by birds feeding in the estuaries and saltmarshes at Ravenglass; radionuclides in contrasting types of coastal pastures and taken up by individual plant species found in west Cumbria; procedures developed and used for the measurement of alpha and gamma emitters in environmental materials. (U.K.)

  10. Naturally occurring radionuclides in agricultural products: An overview

    International Nuclear Information System (INIS)

    Hanlon, E.A.

    1994-01-01

    Low levels of naturally occurring radionuclides exist in phosphatic clays, a by-product of phosphatic mining and beneficiation processes. Concerns about these radionuclides entering the human food chain were an immediate research priority before the phosphate clays could be reclaimed for intensive agricultural purposes. Efforts included the assembly of a large body of data from both sons and plants, part of which were produced by the Polk County (Florida) Mined Lands Agricultural Research/Demonstration Project MLAR/DP. Additional detailed studies involving dairy and beef cattle (Bos taurus) were conducted by researchers working with the MLAR/DP. A national symposium was conducted in which data concerning the MLAR/DP work and other research projects also dealing with naturally occurring radionuclides in agriculture could be discussed. The symposium included invited review papers dealing with the identification of radionuclide geological origins, the geochemistry and movement of radionuclides within the environment, mechanisms of plant uptake, entry points into the food chain, and evaluation of dose and risk assessment to the consumer of low levels of radionuclides. The risk to human health of an individual obtaining 0.1 of his or her dietary intake from crops produced on phosphatic clays increased by 1 in 5 x 10 6 /yr above a control individual consuming no food grown on phosphatic clays. Leaf tissues were found to be generally higher than fruit, grain, or root tissues. The natural range in radionuclide content among various food types was greater than the difference in radionuclides content between the same food produced on phosphatic clays vs. natural soils. 19 refs

  11. (Environmental technology)

    Energy Technology Data Exchange (ETDEWEB)

    Boston, H.L.

    1990-10-12

    The traveler participated in a conference on environmental technology in Paris, sponsored by the US Embassy-Paris, US Environmental Protection Agency (EPA), the French Environmental Ministry, and others. The traveler sat on a panel for environmental aspects of energy technology and made a presentation on the potential contributions of Oak Ridge National Laboratory (ORNL) to a planned French-American Environmental Technologies Institute in Chattanooga, Tennessee, and Evry, France. This institute would provide opportunities for international cooperation on environmental issues and technology transfer related to environmental protection, monitoring, and restoration at US Department of Energy (DOE) facilities. The traveler also attended the Fourth International Conference on Environmental Contamination in Barcelona. Conference topics included environmental chemistry, land disposal of wastes, treatment of toxic wastes, micropollutants, trace organics, artificial radionuclides in the environment, and the use biomonitoring and biosystems for environmental assessment. The traveler presented a paper on The Fate of Radionuclides in Sewage Sludge Applied to Land.'' Those findings corresponded well with results from studies addressing the fate of fallout radionuclides from the Chernobyl nuclear accident. There was an exchange of new information on a number of topics of interest to DOE waste management and environmental restoration needs.

  12. E1B-attenuated onco lytic adenovirus enhances antitumor effect of radionuclide therapy by P53-independent way: cellular basic for radionuclide-viral therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhenwei, Zhang [Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan (China); Shanghai Institute of Biochemistry and Cell Biology, Shanghai Institute for Biological Sciences, Chinese Academy of Sciences, Shanghai (China); Hua, Wu; Xuemei, Zhang [Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan (China); Xinyuan, Liu [Shanghai Institute of Biochemistry and Cell Biology, Shanghai Institute for Biological Sciences, Chinese Academy of Sciences, Shanghai (China)

    2004-07-01

    Purpose: Chemotherapy or external radiation therapy can potentiate the therapeutic effect of E1 B-attenuated oncolytic adenovirus. In this study, the antitumor efficacy of oncolytic adenovirus combined with internal radionuclide therapy was evaluated. Methods: Firstly, viral replication was examined by plaque assay and Southern blotting, after oncolytic adenovirus, ZD55, was exposed to iodine-131. Cell viability was evaluated qualitatively by crystal violet staining and quantitatively by MTT assay. FACS analysis was performed to determine the synergic proapoptotic effect of iodine-131 combined with ZD55. Results: Irradiation of iodine-131 does not influence ZD55 viral DNA replication. In combination with ZD55, iodine-131 can efficiently kill tumor cells in a p53-independent model. ZD55 augments the proapoptotic effect of iodine-131. Conclusion: Radionuclide-viral therapy might be a novel tool for treatment of hepatocarcinoma. (authors)

  13. Nanocarriers for nuclear imaging and radiotherapy of cancer.

    Science.gov (United States)

    Mitra, Amitava; Nan, Anjan; Line, Bruce R; Ghandehari, Hamidreza

    2006-01-01

    Several nanoscale carriers (nanoparticles, liposomes, water-soluble polymers, micelles and dendrimers) have been developed for targeted delivery of cancer diagnostic and therapeutic agents. These carriers can selectively target cancer sites and carry large payloads, thereby improving cancer detection and therapy effectiveness. Further, the combination of newer nuclear imaging techniques providing high sensitivity and spatial resolution such as dual modality imaging with positron emission tomography/computed tomography (PET/CT) and use of nanoscale devices to carry diagnostic and therapeutic radionuclides with high target specificity can enable more accurate detection, staging and therapy planning of cancer. The successful clinical applications of radiolabeled monoclonal antibodies for cancer detection and therapy bode well for the future of nanoscale carrier systems in clinical oncology. Several radiolabeled multifunctional nanocarriers have been effective in detecting and treating cancer in animal models. Nonetheless, further preclinical, clinical and long-term toxicity studies will be required to translate this technology to the care of patients with cancer. The objective of this review is to present a brief but comprehensive overview of the various nuclear imaging techniques and the use of nanocarriers to deliver radionuclides for the diagnosis and therapy of cancer.

  14. Naturally occurring radionuclides in food

    International Nuclear Information System (INIS)

    Djujic, I.

    1995-01-01

    The naturally occurring radionuclides are the major source of radiation exposure to humans. The principal way of natural radiation exposure is the inhalation of 222 Rn decay products (about 85% of the total). The remainder is equally divided between internally deposited radionuclides, cosmic and terrestrial sources. In the present study, the content of 40 K, 210 Pb, 226 Ra, 230 Th, 232 Th and 238 U in representative food samples (milk, pork, beef, potatoes, wheat and corn flour) and samples of different food items that do not represent entire national production but provide interesting additional data for approximative calculation of naturally occurring radionuclide intake is presented. Daily weight of food eaten, participation of food groups, as well as daily intake by food of mentioned naturally occurring radionuclides in the Serbian diet was obtained on the base of house hold budget surveys. The result obtained for daily intake estimates in mBq for Serbian population are 78.1 ( 40 K), 38.2( 210 Pb), 52.3( 226 Ra), 2.0( 230 Th) and 12.5( 238 U). (author)

  15. Potassium cardioplegia: early assessment by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ellis, R.J.; Born, M.; Feit, T.; Ebert, P.A.

    1978-01-01

    Left ventricular function was evaluated by single pass /sup 99m/Tc radionuclide ventriculography when potassium cardioplegia was combined with hypothermia. In 35 patients undergoing myocardial revascularization (3 CABG/patient) in which potassium cardioplegia at 4 0 C was used, no patient developed a myocardial infarction either by electrocardiogram or /sup 99m/Tc pyrophosphate imaging in the postoperative period. In 22 patients, aortic cross-clamp time was greater than 60 min, and the ejection fraction by the single pass radionuclide technique was 50% preoperatively and 53% postoperatively (NS). Wall motion in the single RAO view was not worse postoperatively. No patient required any inotropic agents in the immediate postoperative period. It appears that no significant ventricular impairment occurred in the immediate postoperative period (48 to 72 hours) when potassium cardioplegia combined with hypothermia was used for a 60-minute period

  16. Molecular nuclear imaging for targeting and trafficking

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Jeong, Hwan-Jeong

    2006-01-01

    Noninvasive molecular targeting in living subjects is highly demanded for better understanding of such diverse topics as the efficient delivery of drugs, genes, or radionuclides for the diagnosis or treatment of diseases. Progress in molecular biology, genetic engineering and polymer chemistry provides various tools to target molecules and cells in vivo. We used chitosan as a polymer, and 99m Tc as a radionuclide. We developed 99m Tc-galactosylated chitosan to target asialoglycoprotein receptors for nuclear imaging. We also developed 99m Tc-HYNIC-chitosan-transferrin to target inflammatory cells, which was more effective than 67 Ga-citrate for imaging inflammatory lesions. For an effective delivery of molecules, a longer circulation time is needed. We found that around 10% PEGylation was most effective to prolong the circulation time of liposomes for nuclear imaging of 99m Tc-HMPAO-labeled liposomes in rats. Using various characteristics of molecules, we can deliver drugs into targets more effectively. We found that 99m Tc-labeled biodegradable pullulan-derivatives are retained in tumor tissue in response to extracellular ion-strength. For the trafficking of various cells or bacteria in an intact animal, we used optical imaging techniques or radiolabeled cells. We monitored tumor-targeting bacteria by bioluminescent imaging techniques, dentritic cells by radiolabeling and neuronal stem cells by sodium-iodide symporter reporter gene imaging. In summary, we introduced recent achievements of molecular nuclear imaging technologies in targeting receptors for hepatocyte or inflammatory cells and in trafficking bacterial, immune and stem cells using molecular nuclear imaging techniques

  17. Radionuclides concentration in foods in Peninsular Malaysia

    International Nuclear Information System (INIS)

    Zalina Laili; Muhamat Omar; Mohd Nahar Othman; Md Suhaimi Elias; Esther Philip, Mohd Zaidi Ibrahim; Faizal Azrin Abdul Razalim; Azmi Hassan

    2006-01-01

    The concentrations of natural radionuclides (U-238, Th-232, Ra-226, Ra-228 and K-40) and artificial radionuclides (Cs-137) in fresh, dried and cooked foodstuffs from 30 major towns in Peninsular Malaysia were determined by gamma spectrometry system and Instrumental Neutron Activation Analysis (INAA) technique. A total of 232 samples representing a typical Malaysian community diet were analysed. The results showed that most of the samples contained only natural radionuclides. The percentage of radionuclides detected in the samples were found about 2% for U-238, 9% for Th-232, 49% for Ra-226, 77% for Ra-228, 99% for K-40 and 15% for Cs-137. The radionuclide concentrations were in the ranges of <6.1 - 29.3, <2.0 - 55.8, <0.1 - 34.4, <0.1 - 41, <0.1- 2552.3 and < 0.1 - 6.6 Bq/Kg dry weight for U-238, Th-232, Ra-226, Ra-228 and K-40 and Cs-137 respectively. The study revealed that most of the foodstuffs did not contain U-238. Lentils were found to contain significant concentration of Th-232 (4 - 49 Bq/kg) and can be considered as thorium accumulators. The concentrations of Ra-226 and Ra-228 in leafy vegetables were higher than the fruit and root vegetables. These data can be used as a reference for future food radioactivity monitoring. As edible mushroom and fern had high concentrations of Cs-137, indicating their high ability to accumulate Cs-137, they could be used as indicator plants in the event of radioactive fall outs

  18. Radionuclide patterns of femoral head disease

    Energy Technology Data Exchange (ETDEWEB)

    Webber, M M; Wagner, J; Cragin, M D [California Univ., Los Angeles (USA). Dept. of Radiological Sciences

    1977-12-01

    The pattern of uptake of bone marrow specific radio-sup(99m)Tc sulfur colloid and the pattern of uptake of bone mineral specific radio-sup(99m)Tc pryophosphate may be valuable in assessing bone vascularity in diseases suspected of causing impaired blood supply, or indicate the presence of reactive bone formation. The low energy of the technetium label has been shown to be superior to /sup 18/F and /sup 85/Sr, and leads to greater imaging detail on the scans. Femoral head scanning with mineral and/or marrow specific radionuclides offers the clinician a method of evaluating the status of the femoral head and possibly an early diagnosis of avascular necrosis before roentgenographic changes occur. This study, which reports on a 5-year experience using radionuclide scanning to assess femoral head vascularity, begins with baseline or normal studies followed by variations of the normal pattern. Typical scan patterns of hip pathology described above are also presented.

  19. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  20. Low-cost bioremediation of heavy metals and radionuclides of contaminated soils

    International Nuclear Information System (INIS)

    Sathiyamoorthy, P.; Golan-Goldhrish, A.

    2005-01-01

    The environmental pollution by toxic metals, especially lead (Pb), mercury (Hg), cadmium (Cd), nickel (Ni), copper (Cu), selenium (Se), chromium (Cr) and radionuclides ( 137 Cs, 90 Sr, 238 Pu, 226 Ra) is a potential hazard to health and welfare of mankind. Rapid industrial revolution has left an international legacy of soil and water contaminated with a combination of toxic and potentially carcinogenic compounds and heavy metals. Many of the contaminated sites were abandoned due to high cost of traditional clean-up approaches. Various approaches are being practiced to decontaminate heavy metals and radionuclides from polluted-soil. Remediation of heavy metal and radionuclides contaminated soils poses a significant expense to many industries and government organizations. Remediation cost in the United States and European Union alone is expected to exceed US$20 billion annually. Bioremediation strategy depends on the limitations of technology, cost and nature of the contaminant in the soil. Certain higher plants are capable of accumulation of heavy metals (2-5 %) in roots and shoots to the level far exceeding those present in the soils, these are called hyper-accumulators. Using heavy metal hyper-accumulating higher plants for environmental clean-up of contaminated soil is a recently emerged technology known as 'phytoremediation'. Genetically engineered (Transgenic) plants have a remarkable potential to absorb heavy metals and show a new avenue for biotechnology technique in Phytoremediation. The cost-effective approach of using heavy metal and radionuclide hyper-accumulators in phytoremediation is discussed. (author)

  1. Report on the intercomparison run IAEA-156 radionuclides in clover

    International Nuclear Information System (INIS)

    Strachnov, V.; Valkovic, V.; Dekner, R.

    1991-01-01

    This report contains the results of the intercomparison IAEA-156 on the determination of radionuclides in clover. Initially participants were requested to determine the levels of 134 Cs, 137 Cs, 40 K, 90 Sr and invited to provide data for other radionuclides. The participants included 46 laboratories located in 25 countries, and statistical evaluation of their data yield recommended values for these four radionuclides. Additional radionuclides reported were 210 Pb, 239 Pu and 125 Sb; however, insufficient data exists to statistically determine recommended values for these radionuclides. The following are the recommended values, with confidence intervals, for the most frequently measured radionuclides (reference date: 1 August 1986): 134 Cs 132.1 Bq/kg (126.4-137.7); 137 Cs 264 Bq/kg (254-274); 40 K 657 Bq/kg (637-676); 90 Sr 14.8 Bq/kg (13.4-16.3). Figs and tabs

  2. Indexicality or Technological Intermediate? Moving Image Representation, Materiality, and the Real

    Directory of Open Access Journals (Sweden)

    Verdon James

    2016-09-01

    Full Text Available Drawing on the application of C. S. Peirce’s notion of indexicality, this paper argues that iterative imaging technologies modulate the manner in which moving images represent reality and determine how they are traced back to that referent. Rather than subscribing to the canonical divergence between analogue and digital technologies, the paper argues that current moving image theories do not sufficiently acknowledge the granularity of technology when describing indexical relationships between moving images and the reality they represent. Despite a shared use of analogue technologies, film’s technique of fixing a full frame of movement to a momentarily static strip of light-sensitive celluloid or Mylar is profoundly different from analogue video’s parsing of the image frame to its constituent parts and then recording this signal to continuously moving tape or broadcasting the resulting images. These are particularities of technique and technology, not easily ranked in terms of verisimilitude. The paper concludes that despite a widely accepted indexical analogue/digital divide, the indexical status of analogue video is no different to that of digital video images because both consist of discrete and non-continuous picture elements.

  3. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1983-01-01

    The status of radionuclide generators for chemical research and applications related to the life sciences and biomedical research are reviewed. Emphasis is placed upon convenient, efficient and rapid separation of short-lived daughter radionuclides in a chemical form suitable for use without further chemical manipulation. The focus is on the production of the parent, the radiochemistry associated with processing the parent and daughter, the selection and the characteristic separation methods, and yields. Quality control considerations are briefly noted. The scope of this review includes selected references to applications of radionuclide generators in radiopharmaceutical chemistry, and the life sciences, particularly in diagnostic and therapeutic medicine. The 99 Mo-sup(99m)Tc generator was excluded. 202 references are cited. (orig.)

  4. Positron emission tomography - a new technology in the nuclear medicine image diagnostics

    International Nuclear Information System (INIS)

    Piperkova, E.; Georgiev, R.

    2004-01-01

    In this paper the principles and technical characteristics of PET and PET-CT scanning systems; radiopharmaceuticals used in PET imaging in oncology, cardiology and brain diseases and clinical application of PET are discussed. Based on the technical characteristics, the latest development and the results from its clinical application it could be concluded that PET gives large opportunities to go deeper in the knowledge of brain function and myocardium imaging and is promising imaging method for diagnosing, staging, and treatment effect follow-up of the malignant diseases. As a method of high sensitivity, it could be combined with the high contrast methods, such as CT and MRI to obtain a spatial localisation of the regions with high radionuclide uptake overlapped on the corresponding anatomical structures of the body. These combined methods (PET-CT, PETMRI) contribute significantly to the improvement of the treatment planning and to follow-up the treatment effect

  5. Selected radionuclides important to low-level radioactive waste management

    International Nuclear Information System (INIS)

    1996-11-01

    The purpose of this document is to provide information to state representatives and developers of low level radioactive waste (LLW) management facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the environment. Extensive surveys of available literature provided information for this report. Certain radionuclides may contribute significantly to the dose estimated during a radiological performance assessment analysis of an LLW disposal facility. Among these are the radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha emitting transuranics with half-lives greater than 5 years). This report discusses these radionuclides and other radionuclides that may be significant during a radiological performance assessment analysis of an LLW disposal facility. This report not only includes essential information on each radionuclide, but also incorporates waste and disposal information on the radionuclide, and behavior of the radionuclide in the environment and in the human body. Radionuclides addressed in this document include technetium-99, carbon-14, iodine-129, tritium, cesium-137, strontium-90, nickel-59, plutonium-241, nickel-63, niobium-94, cobalt-60, curium -42, americium-241, uranium-238, and neptunium-237

  6. Selected radionuclides important to low-level radioactive waste management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The purpose of this document is to provide information to state representatives and developers of low level radioactive waste (LLW) management facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the environment. Extensive surveys of available literature provided information for this report. Certain radionuclides may contribute significantly to the dose estimated during a radiological performance assessment analysis of an LLW disposal facility. Among these are the radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha emitting transuranics with half-lives greater than 5 years). This report discusses these radionuclides and other radionuclides that may be significant during a radiological performance assessment analysis of an LLW disposal facility. This report not only includes essential information on each radionuclide, but also incorporates waste and disposal information on the radionuclide, and behavior of the radionuclide in the environment and in the human body. Radionuclides addressed in this document include technetium-99, carbon-14, iodine-129, tritium, cesium-137, strontium-90, nickel-59, plutonium-241, nickel-63, niobium-94, cobalt-60, curium -42, americium-241, uranium-238, and neptunium-237.

  7. Nuclear medicine in Uzbekistan and current status of radionuclide therapy in the country

    International Nuclear Information System (INIS)

    Rasulova, N.; Khodjibekova, M.

    2005-01-01

    Full text: The population of Uzbekistan is 26 million and to cater to this population we have only two nuclear medicine departments; one at the Clinical Centre for Surgery and the other at the Institute of Endocrinology, both situated in Tashkent, the capital city of Uzbekistan. Over the years through its own initiatives and through the support provided by several International Organizations including the IAEA, Uzbekistan has been able to marginally improve its nuclear medicine services. SPECT imaging was introduced through generous support from IAEA in the year 2001. As a result of this, the country is now able to provide modern in vivo nuclear medicine service to the population in a limited scale. At the Clinical Centre for Surgery we are able to provide gamma camera and SPECT imaging services to patients suffering from various nephro-urological, cardiac, neuro and oncological disorders. The other nuclear medicine centre at the Institute of Endocrinology does not have any modern imaging system. However it has been engaged in providing radionuclide therapy service for thyroid diseases like thyroid cancer and hyperthyroidism. From the year 1983 to 1999 the country has reported a total number of 6374 cases of Thyroid Cancer. This number is growing each year, for example the incidence of thyroid cancer in 1989 was 1.95 per 100,000, which has grown to 2.39 per 100,000 in 1999. While the Institute of Endocrinology provides therapeutic service to thyroid diseases, the main role of the Nuclear Medicine Department of Republic Specialized Center of Surgery is in following-up of patients after therapy by performing large dose I-131 whole body imaging, screening for metastases and for assessment of results of radioactive iodine therapy. Besides treating thyroid diseases with I-131 limited services are also available for treatment of polycythemia vera rubra with P-32 and radionuclide therapy for metastatic bone pain. Radionuclide therapy is growing rapidly around the world

  8. HEP technologies to address medical imaging challenges

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Developments in detector technologies aimed at solving challenges in present and future CERN experiments, particularly at the LHC, have triggered exceptional advances in the performance of medical imaging devices, allowing for a spectacular progress in in-vivo molecular imaging procedures, which are opening the way for tailored therapies of major diseases. This talk will briefly review the recent history of this prime example of technology transfer from HEP experiments to society, will describe the technical challenges being addressed by some ongoing projects, and will present a few new ideas for further developments and their foreseeable impact.

  9. Single Photon Emission Computed Tomography/Positron Emission Tomography Imaging and Targeted Radionuclide Therapy of Melanoma: New Multimodal Fluorinated and Iodinated Radiotracers

    International Nuclear Information System (INIS)

    Maisonial, A.; Papon, J.; Bayle, M.; Vidal, A.; Auzeloux, Ph.; Rbah, L.; Bonnet-Duquennoy, M.; Miot-Noirault, E.; Galmier, M.J.; Borel, M.; Madelmont, J.C.; Moins, N.; Chezal, J.M.; Kuhnast, B.; Boisgard, R.; Dolle, F.; Tavitian, B.; Boisgard, R.; Tavitian, B.; Askienazy, S.

    2011-01-01

    This study reports a series of 14 new iodinated and fluorinated compounds offering both early imaging ( 123 I, 124 I, 18 F) and systemic treatment ( 131 I) of melanoma potentialities. The biodistribution of each 125 I-labeled tracer was evaluated in a model of melanoma B16F0-bearing mice, using in vivo serial γ scintigraphic imaging. Among this series, [ 125 I]56 emerged as the most promising compound in terms of specific tumoral uptake and in vivo kinetic profile. To validate our multimodality concept, the radiosynthesis of [ 18 F]56 was then optimized and this radiotracer has been successfully investigated for in vivo PET imaging of melanoma in B16F0- and B16F10-bearing mouse model. The therapeutic efficacy of [ 131 I]56 was then evaluated in mice bearing subcutaneous B16F0 melanoma, and a significant slow down in tumoral growth was demonstrated. These data support further development of 56 for PET imaging ( 18 F, 124 I) and targeted radionuclide therapy ( 131 I) of melanoma using a single chemical structure. (authors)

  10. Radionuclide diagnosis of splenic rupture in infectious mononucleosis

    International Nuclear Information System (INIS)

    Vezina, W.C.; Nicholson, R.L.; Cohen, P.; Chamberlain, M.J.

    1984-01-01

    Spontaneous splenic rupture is a rare but serious complication of infectious mononucleosis. Although radionuclide spleen imaging is a well accepted method for diagnosis of traumatic rupture, interpretation can be difficult in the setting of mononucleosis, as tears may be ill-defined and diagnosis hampered by inhomogeneous splenic uptake. Four proven cases of spontaneous rupture are presented, three of which illustrate these diagnostic problems

  11. Protein concentrate production from the biomass contaminated with radionuclides

    International Nuclear Information System (INIS)

    Nizhko, V.F.; Shinkarenko, M.P.; Polozhaj, V.V.; Krivchik, O.V.

    1992-01-01

    Coefficients of radionuclides accumulation are determined for traditional and rare forage crops grown on contaminated soils. It is shown that with low concentration of radionuclides in soil minimal level of contamination were found in the biomass of lupine (Lupinus luteus L.) and sainfoin (Onobrychis hybridus L.). Relatively high levels of contamination were found in comfrey (Symphytum asperum Lepech.) and bistort (Polygonum divaricatum L.). Comparatively low accumulation coefficients in case of higher density of soil contamination were observed for white and yellow sweetclovers (Melilotus albus Medik. and M. officinalis (L.) Desr.), while higher values of coefficients were found for bird's-foot trefoil (Lotus corniculatus L.), white clover (Trifolium repens L.) and alsike clover (t. hybridum L.). Biomass of white sweet-clover and alsike clover has been processed to produce leaf protein concentrate. It is shown that with biomass contamination of 1 kBq/kg and above conventional technology based on thermal precipitation of the protein does not provide production of pure product. More purified protein concentrates are obtained after two-stage processing of the biomass

  12. The administered activity of radionuclides in nuclear medicine

    International Nuclear Information System (INIS)

    Nakamura, Mototoshi; Koga, Sukehiko; Kondo, Takeshi

    1993-01-01

    A survey of 104 hospitals was conducted to determine the administered activity of radionuclides. Eighty-five hospitals responded, and reported a total of 119,614 examinations in one year. The examinations included: bone scintigraphy, 26.4%; thallium-201 ( 201 Tl) myocardial scintigraphy, 15.5%; gallium-67 ( 67 Ga) scintigraphy, 13.3%; N-isopropyl-p-[ 123 I] iodoamphetamine (IMP) brain perfusion scintigraphy, 7.0%. The administered activity was corrected by body weight only for children at more than 80% of the responding hospitals. The number of hospitals that reported over-administration of radionuclide varied according to the type of scintigraphy performed: bone, 76%; inflammatory ( 67 Ga), 93%; myocardial ( 201 Tl), 89.2%; brain (IMP), 8.5%. The administered activity of IMP was closer to the upper limits specified in the Recommendations on Standardization of Radionuclide Imaging by the Japan Radioisotope Association (1987), because IMP is very expensive and is supplied as single vials. The highest average effective dose was for myocardial scintigraphy, the second-highest for inflammatory scintigraphy, and the third-highest for bone scintigraphy. In 201 Tl and 67 Ga scintigraphy, the entire contents of the vial may be administered two days before the expiration date, because the ratio of (true patient administered activity) to (declared patient administered activity) is similar to the ratio of (radioactivity on the day of supply) to (radioactivity on the day of expiration). The factors that influence administered activity are through put, price of the radionuclide, and whether the radionuclide is sold as a single vial. In order to decrease the effective dose, it is necessary to establish a close cooperation between medical personnel, the makers of radiopharmaceuticals, and manufactures of gamma cameras. (author)

  13. Hydrology/Radionuclide Migration Program and related research activities

    International Nuclear Information System (INIS)

    Jones, M.A.

    1992-02-01

    This report presents the results of technical studies conducted under the Hydrology/Radionuclide Migration Program (HRMP) at the Nevada Test Site (NTS) for the period of October 1, 1985 through September 30, 1986. The HRMP was initiated in 1973 as the Radionuclide Migration Program to study and better understand the hydrologic systems of the NTS and potential movement and rates of movement of radionuclides and other contaminants injected into these systems by underground nuclear testing

  14. Digital image technology and a measurement tool in physical models

    CSIR Research Space (South Africa)

    Phelp, David

    2006-05-01

    Full Text Available Advances in digital image technology has allowed us to use accurate, but relatively cost effective technology to measure a number of varied activities in physical models. The capturing and manipulation of high resolution digital images can be used...

  15. Removal of radionuclides from process streams - a review

    International Nuclear Information System (INIS)

    Itzkovitch, I.J.; Ritcey, G.M.

    1979-04-01

    This report details the origin and control of radium 226, thorium 230 and lead 210 contamination of mill effluent streams from conventional and non-conventional milling of uranium ores, reviews the basic chemistry of the radionuclides as it relates to potential alternatives for control and presents these alternatives along with a summary of published cost data. The conclusions from the study indicate that the current technology, using sulphuric acid processing, solubilizes only a comparatively small quantity of the radionuclides, with the solid containing approximately the same concentration as the original ore. Present technolgy does not provide for complete removal and isolation of the radionuclides. Current practice for control of thorium 230 in liquid effluents by neutralization is adequate to meet present Governmental guidelines. Radium in solution is presently being controlled by precipitation with barium chloride but levels of less than 3 pCi/L of soluble radium could be difficult if not impossible to achieve consistently by this treatment. Indications are that the concentration of lead 210 in liquid effluent may exceed present guidelines. No specific control procedures are employed for lead 210. Methods of isolating radium 226 are required for treating effluents from conventional milling as well as from alternative processes under development. Ion exchange is suggested as a means of isolating these radionuclides. (OT)

  16. Recent status of research activities for development of CTBT-related technologies in JAERI

    International Nuclear Information System (INIS)

    Hirota, Naoki; Houkida, Takanori; Inoue, Yoji

    2003-08-01

    This report describes research activities of the R and D Group for Non-Proliferation Technology related to the Comprehensive Nuclear-Test-Ban Treaty (CTBT) verification regime. The main subjects of this report are (1) an overview of the CTBT verification regime, (2) preparation of the National Data Center for radionuclide data, (3) construction and operation of the radionuclide monitoring stations at Takasaki and Okinawa and the certified radionuclide laboratory at Tokai in Japan. We have participated in an intercomparison test internationally organized for the certified laboratories and the test results are given here. Scientific application of the CTBT-related technologies to environmental researches is also depicted. (author)

  17. Concentration of some radionuclides in some popular sudanese medicinal plants

    International Nuclear Information System (INIS)

    Sagiroun, M. I. A.

    2012-10-01

    In this study was measured concentration of naturally occurring radionuclides 2 38U , 2 32T h and 4 0K in samples of sudanese medicinal plants. The radionuclide activity concentrations in samples analyzed ranged from 4.09 to 41.07 Bq kg -1 for 2 38T h and from 353.14 to 2270.21 Bq kg -1 for 4 0k . No trace of artificial radionuclide was determined in all the samples. The effective dose due to the presence of these radionuclides was estimated and found to be 0.524 mSv/year which is well below the permissible levels. (Author)

  18. Radionuclides in radiation-induced bystander effect; may it share in radionuclide therapy?

    Science.gov (United States)

    Widel, M

    2017-01-01

    For many years in radiobiology and radiotherapy predominated the conviction that cellular DNA is the main target for ionizing radiation, however, the view has changed in the past 20 years. Nowadays, it is assumed that not only directed (targeted) radiation effect, but also an indirect (non-targeted) effect may contribute to the result of radiation treatment. Non-targeted effect is relatively well recognized after external beam irradiation in vitro and in vivo, and comprises such phenomena like radiation-induced bystander effect (RIBE), genomic instability, adaptive response and abscopal (out of field) effect. These stress-induced and molecular signaling mediated phenomena appear in non-targeted cells as variety responses resembling that observed in directly hit cells. Bystander effects can be both detrimental and beneficial in dependence on dose, dose-rate, cell type, genetic status and experimental condition. Less is known about radionuclide-induced non-targeted effects in radionuclide therapy, although, based on characteristics of the radionuclide radiation, on experiments in vitro utilizing classical and 3-D cell cultures, and preclinical study on animals it seems obvious that exposure to radionuclide is accompanied by various bystander effects, mostly damaging, less often protective. This review summarizes existing data on radionuclide induced bystander effects comprising radionuclides emitting beta- and alpha-particles and Auger electrons used in tumor radiotherapy and diagnostics. So far, separation of the direct effect of radionuclide decay from crossfire and bystander effects in clinical targeted radionuclide therapy is impossible because of the lack of methods to assess whether, and to what extent bystander effect is involved in human organism. Considerations on this topic are also included.

  19. Positron emitting radionuclides for South Africa

    International Nuclear Information System (INIS)

    Wynchbank, S.; Van der Walt, T.N.; Sharpey-Shafer, J.

    2004-01-01

    Full text: In South Africa there are currently two projects underway to supply and utilise positron emitting radionuclides for imaging in clinical nuclear medicine facilities. The advantages and applications of such radio nuclides are numerous and well known. However the premier initial application will be to employ 1BF, at first in the compound fluorine-18 fluorodeoxyglucose ( 18 F)-FDG, for patients with cancers and neoplasms. The two projects are sited at iThemba LABS, where production of a generator supplying 66 Ga and the provision of ( 18 F]-FDG, are in an advanced state of planning; the former already fully financed by the Innovation Fund of the National Research Foundation. The two positron emitting radionuclides, 18 F and 68 Ge, will be produced using a cyclotron induced reaction on 1802 and Ga, respectively, at iThemba LABS. The 68 Ge/ 68 Ga generator consists of an anion exchanger loaded with 68 Ge, which decays to 68 Ga. The resulting radiopharmaceuticals, ( 18 F]-FDG and 68 Ga citrate, will be produced by the Radionuclide Production Group of iThemba LABS, using well described methods. However the structures and processes to be used in the generator to provide 68 Ga are novel and will be explained. Initially provision of the CBF]-FDG will be to selected clinical medicine facilities in the Western Cape and Gauteng. It should be noted that the logistical problems of providing this radiopharmaceutical (which are much complicated by its short half life of 109.7 min) to Gauteng, were shown to be surmountable in the 1970s, by a regular delivery of 18 F between Gauteng and Cape Town, after the advent of a commercial service using jet aircraft. The obvious requirement that there should be appropriate nuclear medicine facilities to image patients, at the sites to which the positron emitting radiopharmaceuticals will be supplied, has been addressed. Proposed solutions will be outlined, in terms of a dedicated positron emission tomography (PET) camera and a gamma

  20. Transport of radionuclides from the LAMPF lagoons

    International Nuclear Information System (INIS)

    Ferenbaugh, R.W.; Purtymun, W.D.

    1985-01-01

    Monitoring of the discharge water from the Los Alamos Meson Physics Facility lagoons continued during June and December of 1983. The list of radionuclides being monitoring includes 7 Be, 57 Co, 134 Cs, 3 H, 54 Mn, 22 Na, and 83 Rb. The sampling locations and the data obtained to date are presented. Movement of radionuclides around the lagoons has been described in a previous report. 1 reference, 1 table

  1. Transport of Gas Phase Radionuclides in a Fractured, Low-Permeability Reservoir

    Science.gov (United States)

    Cooper, C. A.; Chapman, J.

    2001-12-01

    The U.S. Atomic Energy Commission (predecessor to the Department of Energy, DOE) oversaw a joint program between industry and government in the 1960s and 1970s to develop technology to enhance production from low-permeability gas reservoirs using nuclear stimulation rather than conventional means (e.g., hydraulic and/or acid fracturing). Project Rio Blanco, located in the Piceance Basin, Colorado, was the third experiment under the program. Three 30-kiloton nuclear explosives were placed in a 2134 m deep well at 1780, 1899, and 2039 m below the land surface and detonated in May 1973. Although the reservoir was extensively fractured, complications such as radionuclide contamination of the gas prevented production and subsequent development of the technology. Two-dimensional numerical simulations were conducted to identify the main transport processes that have occurred and are currently occurring in relation to the detonations, and to estimate the extent of contamination in the reservoir. Minor modifications were made to TOUGH2, the multiphase, multicomponent reservoir simulator developed at Lawrence Berkeley National Laboratories. The simulator allows the explicit incorporation of fractures, as well as heat transport, phase change, and first order radionuclide decay. For a fractured two-phase (liquid and gas) reservoir, the largest velocities are of gases through the fractures. In the gas phase, tritium and one isotope of krypton are the principle radionuclides of concern. However, in addition to existing as a fast pathway, fractures also permit matrix diffusion as a retardation mechanism. Another retardation mechanism is radionuclide decay. Simulations show that incorporation of fractures can significantly alter transport rates, and that radionuclides in the gas phase can preferentially migrate upward due to the downward gravity drainage of liquid water in the pores. This project was funded by the National Nuclear Security Administration, Nevada Operations Office

  2. RIVER-RAD, Radionuclide Transport in Surface Waters

    International Nuclear Information System (INIS)

    1996-01-01

    1 - Description of program or function: RIVER-RAD assesses the potential fate of radionuclides released to rivers. The model is simplified in nature and is intended to provide guidance in determining the potential importance of the surface water pathway, relevant transport mechanisms, and key radionuclides in estimating radiological dose to man. 2 - Method of solution: A compartmental linear transfer model is used in RIVER-RAD. The river system model in the code is divided into reaches (compartments) of equal size, each with a sediment compartment below it. The movement of radionuclides is represented by a series of transfers between the reaches, and between the water and sediment compartments of each reach. Within each reach (for both the water and sediment compartments), the radionuclides are assumed to be uniformly mixed. Upward volatilization is allowed from the water compartment, and the transfer of radionuclides between the reaches is determined by the flow rate of the river. Settling and resuspension velocities determine the transfer of absorbed radionuclides between the water and sediment compartments. Radioactive decay and decay-product buildup are incorporated into all transport calculations for all radionuclide chains specified by the user. Each nuclide may have unique input and removal rates. Volatilization and radiological decay are considered as linear rate constants in the model. 3 - Restrictions on the complexity of the problem: None noted

  3. Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness

    CERN Document Server

    Maiti, Moumita; Mendonça, Tania M; Stora, Thierry; Lahiri, Susanta

    2014-01-01

    This is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) were identified in the samples with the help of time resolved gamma-ray spectroscopy. However, there is no signature of formation of At radioisotopes, which can be produced by the interaction of secondary particles, typical for thick targets.

  4. Accelerator mass spectrometry analyses of environmental radionuclides: sensitivity, precision and standardisation

    Science.gov (United States)

    Hotchkis; Fink; Tuniz; Vogt

    2000-07-01

    Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. AMS allows an isotopic sensitivity as low as one part in 10(15) for 14C (5.73 ka), 10Be (1.6 Ma), 26Al (720 ka), 36Cl (301 ka), 41Ca (104 ka), 129I (16 Ma) and other long-lived radionuclides occurring in nature at ultra-trace levels. These radionuclides can be used as tracers and chronometers in many disciplines: geology, archaeology, astrophysics, biomedicine and materials science. Low-level decay counting techniques have been developed in the last 40-50 years to detect the concentration of cosmogenic, radiogenic and anthropogenic radionuclides in a variety of specimens. Radioactivity measurements for long-lived radionuclides are made difficult by low counting rates and in some cases the need for complicated radiochemistry procedures and efficient detectors of soft beta-particles and low energy x-rays. The sensitivity of AMS is unaffected by the half-life of the isotope being measured, since the atoms not the radiations that result from their decay, are counted directly. Hence, the efficiency of AMS in the detection of long-lived radionuclides is 10(6)-10(9) times higher than decay counting and the size of the sample required for analysis is reduced accordingly. For example, 14C is being analysed in samples containing as little as 20 microg carbon. There is also a world-wide effort to use AMS for the analysis of rare nuclides of heavy mass, such as actinides, with important applications in safeguards and nuclear waste disposal. Finally, AMS microprobes are being developed for the in-situ analysis of stable isotopes in geological samples, semiconductors and other materials. Unfortunately, the use of AMS is limited by the expensive accelerator technology required, but there are several attempts to develop compact AMS spectrometers at low (advances in AMS

  5. Alien vision exploring the electromagnetic spectrum with imaging technology

    CERN Document Server

    Richards, Austin A

    2011-01-01

    Austin Richards takes readers on a visual tour of the electromagnetic spectrum beyond the range of human sight, using imaging technology as the means to ""see"" invisible light. Dozens of colorful images and clear, concise descriptions make this an intriguing, accessible technical book. Richards explains the light spectrum, including visible light, and describes the advanced imaging technologies that enable humans to synthesize our own version of ""alien"" vision at different wavelengths, with applications ranging from fire fighting and law enforcement to botany and medicine. The second editio

  6. Extension of Studies with 3M Empore TM and Selentec MAG *SEP SM Technologies for Improved Radionuclide Field Sampling

    International Nuclear Information System (INIS)

    Beals, D.M.; Bibler, J.P.; Brooks, D.A.

    1996-01-01

    The Savannah River Technology Center is evaluating new field sampling methodologies to more easily determine concentrations of radionuclides in aqueous systems. One methodology studied makes use of 3M EmporeTM disks. The disks are composed of selective resins embedded in a Teflon support. The disks remove the ion of interest from aqueous solutions when the solution is passed through the disk. The disk can then be counted directly to quantify the isotope of interest. Four types of disks were studied during this work: for the extraction of technetium (two types), cesium, plutonium, and strontium. A sampler has been developed for automated, unattended, in situ use of the EmporeTM disks

  7. Extension of Studies with 3M Empore TM and Selentec MAG *SEP SM Technologies for Improved Radionuclide Field Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Beals, D.M. [Westinghouse Savannah River Company, AIKEN, SC (United States); Bibler, J.P.; Brooks, D.A.

    1996-07-10

    The Savannah River Technology Center is evaluating new field sampling methodologies to more easily determine concentrations of radionuclides in aqueous systems. One methodology studied makes use of 3M EmporeTM disks. The disks are composed of selective resins embedded in a Teflon support. The disks remove the ion of interest from aqueous solutions when the solution is passed through the disk. The disk can then be counted directly to quantify the isotope of interest. Four types of disks were studied during this work: for the extraction of technetium (two types), cesium, plutonium, and strontium. A sampler has been developed for automated, unattended, in situ use of the EmporeTM disks.

  8. Investigation of transformation of radionuclides in soils oil polluted

    International Nuclear Information System (INIS)

    Humbatov, F.Y.; Ahmedov, M.M.; Ibadov, N.A.; Balayev, V.S.

    2004-01-01

    Full text: Despite of constant improvement in view of last achievement of a science and technique the technological processes of oil production are accompanied by coming in environment a number of chemical substances - oil products, poly aromatic and aromatic hydrocarbons, salts of heavy metals, including soluble and insoluble compound of stable and radioactive isotopes of metals, various gases etc. Technological processes of production, transportation of crude oil and its complex processing is followed with essential pollution of soil by oil products, radioactive substances because of crude oil and grounds waters spillage. The problem of radioactive pollution of environment in oil-extracting sites and especially in old deposits of Apsheron peninsula, in particular, in oil fields of Surakhani and Balakhani by the various factors is rather urgent in Azerbaijan. On a whole, radioactive-ecological situation is defined by the quantitative contents of natural radionuclides, chemical structure of grounds waters and oil, and also accumulation of radioactive substances in pipelines and modular items as crystals radiobarits or calcium and magnesium salts. Systemic and complex research on this direction will allow creating the mechanism of radionuclides transformation in oil-contaminated soils. The condition of radioactive background of soil cover of oil field in Surakhani was studied in our researches. The soil samples taken from various depths of deposit are investigated. The quantities of total oil components, aliphatic and poly aromatic hydrocarbons, heavy metals and natural radionuclides are determined. The attempt is made to explain dependence of various meanings of carried out analyses on the depth of taken samples. In summary it is necessary to note, that the researches on more detailed study of influence of the factors on processes of accumulation and transformation natural radionuclides proceed. The systemic researches on this direction will allow securing of

  9. Implementation of sum-peak method for standardization of positron emission radionuclides

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Mercia Liane de; Lima, Fernando Roberto de Andrade

    2015-01-01

    Positron Emission Tomography (PET) is being increasingly recognized as an important quantitative imaging tool for diagnosis and assessing response to therapy. As correct dose administration plays a crucial part in nuclear medicine, it is important that the instruments used to assay the activity of the short-lived radionuclides are calibrated accurately, with traceability to the national or international standards. The sum-peak method has been widely used for radionuclide standardization. The purpose of this study was to implement the methodology for standardization of PET radiopharmaceuticals at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE). (author)

  10. The behavior of radionuclides in the soils of Rocky Flats, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Litaor, M I [Tel-Hai Rodman Coll., Upper Galilee (Israel); Barth, G; Zika, E M; Litus, G; Moffitt, J; Daniels, H [Colorado Univ., Civil and Environmental Engineering Dept., Boulder, CO (United States)

    1998-05-01

    Radionuclide contamination of soils in Rocky Flats, Colorado, resulted from leaking drums of Pu-contaminated oil stored at an outdoor area. To evaluated the mechanisms of radionuclide transport from the contaminated soils to groundwater, an advanced monitoring system was installed across a toposequence. The impact of natural rain, snowmelt, and large-scale rain simulations on the mobility and distribution of the radionuclides in soil interstitial water was studied. The distribution of radionuclides during the monitoring period from 1993 to 1995 suggested that Pu-239 + 240 and Am-241 are largely immobile in semi-arid soils. Fractionation of Pu-239 + 240 and Am-241 to different particle sizes in the soil interstitial water suggested that most of the radionuclides (83-97%) were associated with suspended particles, whereas the level of radionuclides associated with colloidal (0.45 {mu}m > X > 1 nm) and nonfilterable (< 1 nm) fractions ranged from 1.5 to 15%. (author).

  11. Bounding Radionuclide Inventory and Accident Consequence Calculation for the 1L Target

    International Nuclear Information System (INIS)

    Kelsey, Charles T. IV

    2011-01-01

    A bounding radionuclide inventory for the tungsten of the Los Alamos Neutron Science Center (LANSCE) IL Target is calculated. Based on the bounding inventory, the dose resulting from the maximum credible incident (MCI) is calculated for the maximally exposed offsite individual (MEOl). The design basis accident involves tungsten target oxidation following a loss of cooling accident. Also calculated for the bounding radionuclide inventory is the ratio to the LANSCE inventory threshold for purposes of inventory control as described in the target inventory control policy. A bounding radionuclide inventory calculation for the lL Target was completed using the MCNPX and CINDER'90 codes. Continuous beam delivery at 200 (micro)A to 2500 mA·h was assumed. The total calculated activity following this irradiation period is 205,000 Ci. The dose to the MEOI from the MCI is 213 mrem for the bounding inventory. The LANSCE inventory control threshold ratio is 132.

  12. Radionuclide cardiography in medical practice

    International Nuclear Information System (INIS)

    Strangfeld, D.; Mohnike, W.; Schmidt, J.; Heine, H.; Correns, H.J.

    1986-01-01

    This publication is a compendium on all aspects of radionuclide diagnostics concerning cardiovascular system diseases. Starting with introductory remarks on the control of cardiovascular diseases the contribution of radionuclide cardiology to functional cardiovascular diagnostics as well as pathophysiological and pathobiochemical aspects of radiocardiography are outlined. Radiopharmaceuticals used in radiocardiography, physical and technical problems in application of radionuclides and their measuring techniques are discussed. In individual chapters radionuclide ventriculography, myocardial scintiscanning, circulatory diagnostics, radionuclide diagnostics of arterial hypertension, of thrombosis and in vitro diagnostics of thrombophilia are treated in the framework of clinical medicine

  13. Advanced microwave/millimeter-wave imaging technology

    International Nuclear Information System (INIS)

    Shen, Zuowei; Yang, Lu; Luhmann, N.C. Jr.

    2007-01-01

    Millimeter wave technology advances have made possible active and passive millimeter wave imaging for a variety of applications including advanced plasma diagnostics, radio astronomy, atmospheric radiometry, concealed weapon detection, all-weather aircraft landing, contraband goods detection, harbor navigation/surveillance in fog, highway traffic monitoring in fog, helicopter and automotive collision avoidance in fog, and environmental remote sensing data associated with weather, pollution, soil moisture, oil spill detection, and monitoring of forest fires, to name but a few. The primary focus of this paper is on technology advances which have made possible advanced imaging and visualization of magnetohydrodynamic (MHD) fluctuations and microturbulence in fusion plasmas. Topics of particular emphasis include frequency selective surfaces, planar Schottky diode mixer arrays, electronically controlled beam shaping/steering arrays, and high power millimeter wave local oscillator and probe sources. (author)

  14. The IAEA co-ordinated research programme on activation cross sections for the generation of long-lived radionuclides of importance in fusion reactor technology. Final report

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1997-07-01

    The present report summarizes the final results of the IAEA Co-ordinated Research Programme on ''Activation Cross Section for the Generator of Long-lived Radionuclides of Importance in Fusion Reactor Technology''. The goal of the CRP was to obtain reliable information (experimental and evaluated) for 16 long-lived activation reactions of special importance to fusion reactor technology. By limiting the scope of the CRP to just 16 reactions it was possible to establish a very effective focus to the joint effort of many laboratories that has led to the generation of a set of valuable new data which provide satisfactory answers to several questions of technological concern to fusion. (author). 11 refs, 5 tabs

  15. Use of radionuclide techniques for assessment of splenic function and detection of splenic remnants

    International Nuclear Information System (INIS)

    Ganguly, S.; Sinha, S.; Sarkar, B.R.; Basu, S.; Ghosh, S.

    1998-01-01

    Full text: The spleen is often involved in hematological malignancies; it is also the site of RBC destruction in thalassemia and ITP. In latter cases, splenectomy is often performed and postoperatively, detection of functioning splenic remnants affect the prognosis adversely. In this study, we assessed the usefulness of radionuclide techniques in : a) assessment of splenic function in primarily non-splenic diseases (benign or malignant), and b) detection of splenic remnant after splenectomy. 12 patients of splenomegaly and 5 patients after splenectomy underwent splenic imaging; imaging was performed using both 99m Tc-sulphur colloid (with first pass) and 99m Tc labelled heat denatured RBCs as tracers. Thus splenic perfusion, morphology and RBC trapping functions were all assessed. The colloid images usually matched the RBC images except in 2 cases where photogenic areas (presumably infarcts) were visualized on RBC scans that were missed on colloid scans. Three of the post splenectomy cases revealed functioning splenic remnants, which was also better visualized on RBC scans. It is concluded that radionuclide imaging could be used regularly for assessing function of spleen, or detecting splenic remnants

  16. Image Fusion Technologies In Commercial Remote Sensing Packages

    OpenAIRE

    Al-Wassai, Firouz Abdullah; Kalyankar, N. V.

    2013-01-01

    Several remote sensing software packages are used to the explicit purpose of analyzing and visualizing remotely sensed data, with the developing of remote sensing sensor technologies from last ten years. Accord-ing to literature, the remote sensing is still the lack of software tools for effective information extraction from remote sensing data. So, this paper provides a state-of-art of multi-sensor image fusion technologies as well as review on the quality evaluation of the single image or f...

  17. Influence of marine sediments in the distribution of the main radionuclides of the effluent from the nuclear power plant Almirante Alvaro Alberto (Unit 1)

    International Nuclear Information System (INIS)

    Brugnara, Miriam

    1977-01-01

    This study aimed to: 1) Characterize bottom sediments of the Angra dos Reis region, in the dispersion area of the effluent of the central Almirante Nuclear Alvaro Alberto, Unit 1. 2) Determining the adsorption capacity of these sediments to the long half-life and mean radionuclides to be released in the reactor effluent in a higher concentration. 3) Estimate the fraction of the different studied radionuclides that will be immobilized in sediments. 4) Identify critical radionuclides available for food chain

  18. Production of radionuclides with generators

    International Nuclear Information System (INIS)

    Khujaev, S.; Egamediev, S.Kh.

    2004-01-01

    (75-85%) independently of the 99 Mo activity (250 - 1000 mCi) at the beginning and the end (up to 15 days) of the period of use. 188 W- 188 Re generator. 188 Re (T 1/2 =16.9 hours, β - m ax=2.12 MeV; γ=155 keV, 15%) is currently attractive radionuclide for radiotherapeutic applications. Rhenium-188 is produced by decay of tungsten-188 (T 1/2 =69.4 d) which can be produced by double neutron capture on enriched 188 W targets with high neutron flux. The specific activity of 188 W is reached up to 2 Ci/g. The optimal conditions for separation of 188 Re from the parent nuclide 188 W are studied. It is shown that the optimal separation condition is using acid-treated aluminium-oxide column to adsorb 188 W as isopolytungstate at pH solution of 2-4. 188 Re is eluted with 0.9% NaCl solution. The characteristics of the sodium perrhenate obtained from our generator are: radiochemical purity is 99.8%; pH 4.0-6.0; yield of 188 Re is 70-75%; breakthrough of 188 W is less than 10 -3 %. 68 Ge- 68 Ga generator. The nuclide 68 Ga (T 1/2 =68.3 min) produced by the electron capture decay of 68 Ge (T 1/2 =288 d) is useful for calibrating positron emission tomography (PET) systems. The 68 Ge is normally produced by both 66 Zn(α,2n) 68 Ge and 69 Ga(p,2n) 68 Ge nuclear reactions. The separation of daughter 68 Ga from parent 68 Ge on both aluminium oxide and tin dioxide are studied. In case of tin dioxide the optimal separation of daughter 68 Ga from parent 68 Ge can be achieved by using 1 M HCl as the eluent. It is shown that the tin dioxide - 1 M HCl generator system provides high yields of 68 Ga (75-80%) with low levels of breakthrough of 68 Ge (2 · 10 -4 %). However, the obtained final product - 68 Ga eluate in 1 M HCl can not be used for direct preparation of radiopharmaceuticals. In case of aluminium oxide we have found that preliminary annealing of aluminium oxide at 1000 deg C provides the best conditions for separation of 68 Ge- 68 Ga radionuclide chain in 0.1 M hydrochloric acid

  19. Metabolism of radionuclides in domestic animals

    International Nuclear Information System (INIS)

    Wirth, E.; Leising, C.

    1986-01-01

    The reactor accident at Chernobyl has shown that shortly after the contamination of the environment radionuclides can be found in animal products. The main contamination pathways of domestic animas are: uptake of radionuclides by foodstuffs; uptake of radionuclides by contaminated drinking water; uptake of radionuclides by inhalation; uptake of radionuclides through skin; uptake of radionuclides by ingestion of soil particles. Generally the uptake of radionuclides by food is the dominant exposure pathway. In rare cases the inhalation of radionuclides or the uptake by drinking water may be of importance. The metabolism of incorporated radionuclides is comparable to the respective metabolism of essential mass or trace elements or heavy metals. Radioisotopes of essential elements are for instance iron 55, manganese 54, cobalt 58 and cobalt 60. Other elements are typical antagonists to essential elements, e.g. strontium 90 is an antagonist to calcium or cesium 137 to potassium. Lead 210 and plutonium 239 behave similarly as heavy metals. Generally the knowledge of the metabolism of trace and mass elements, of antagonistic and synergistic elements and heavy metals can be applied to these radionuclides

  20. Role of radionuclide imaging in the diagnosis of chondrosarcoma

    International Nuclear Information System (INIS)

    McLean, R.G.; Choy, D.; Hoeschl, R.; Nayanar, V.; Murray, I.P.

    1985-01-01

    The diagnosis of chondrosarcoma may be difficult if there is an atypical radiographic appearance or an inconclusive biopsy. Radionuclide bone scans of 13 patients with chondrosarcoma were reviewed to assess if a pattern of scan features could be recognized in association with this tumor. A combination, including increased blood pool activity, moderate intensity of uptake, patchy uptake with cortical predominance of activity, minimal distortion of bony outline, and a well-defined scintigraphic margin, occurred regularly in the series. Recognition of this characteristic pattern of scintigraphic features in cases of suspected chondrosarcoma may assist in the diagnostic assessment

  1. Potential radionuclide emissions from stacks on the Hanford Site. Part 1: Dose assessment

    International Nuclear Information System (INIS)

    Davis, W.E.; Barnett, J.M.

    1994-06-01

    On February 3, 1993, the US Department of Energy, Richland Operations Office (RL) received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the US Environmental Protection Agency (EPA), Region 10. The Compliance Plan specified that a dose assessment would be performed for 84 Westinghouse Hanford Company (WHC) stacks registered with the Washington State Department of Health (WAC 246-247) on the Hanford Site. Stacks that have the potential emissions to cause an effective dose equivalent (EDE) to a maximum exposed individual (MEI) greater than 0.1 mrem y -1 must be monitored continuously for radionuclide emissions. Five methods were approved by EPA, Region 10 for performing the assessments: Release Fractions from Appendix D of 40 CFR 61, Back Calculations Using A HEPA Filtration Factor, Nondestructive Assay of HEPA Filters, A Spill Release Fraction, and Upstream of HEPA Filter Air Concentrations. The first two methods were extremely conservative for estimating releases. The third method which used a state-of-the-art portable gamma spectrometer, yielded surprising results from the distribution of radionuclides on the HEPA filters. All five methods are described

  2. Imaging the pancreas: from ex vivo to non-invasive technology

    DEFF Research Database (Denmark)

    Holmberg, D; Ahlgren, U

    2008-01-01

    While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real-time monit......While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real...

  3. Workshop on development of radionuclide getters for the Yucca Mountain waste repository: proceedings.

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Robert Charles; Lukens, Wayne W. (Lawrence Berkeley National Laboratory)

    2006-03-01

    The proposed Yucca Mountain repository, located in southern Nevada, is to be the first facility for permanent disposal of spent reactor fuel and high-level radioactive waste in the United States. Total Systems Performance Assessment (TSPA) analysis has indicated that among the major radionuclides contributing to dose are technetium, iodine, and neptunium, all of which are highly mobile in the environment. Containment of these radionuclides within the repository is a priority for the Yucca Mountain Project (YMP). These proceedings review current research and technology efforts for sequestration of the radionuclides with a focus on technetium, iodine, and neptunium. This workshop also covered issues concerning the Yucca Mountain environment and getter characteristics required for potential placement into the repository.

  4. Osteogenic sarcoma : imaging advances

    Energy Technology Data Exchange (ETDEWEB)

    Gooding, C A [California Univ., San Francisco, CA (United States)

    1996-12-31

    The contents are classification of osteosarcoma, radiographic appearance, radionuclide imaging, PET - positron emission tomography scanning, arteriography, computed tomography, MRI imaging, response of chemotherapy (43 refs.).

  5. Osteogenic sarcoma : imaging advances

    International Nuclear Information System (INIS)

    Gooding, C.A.

    1995-01-01

    The contents are classification of osteosarcoma, radiographic appearance, radionuclide imaging, PET - positron emission tomography scanning, arteriography, computed tomography, MRI imaging, response of chemotherapy (43 refs.)

  6. Radionuclide bone imaging in suspected skeletal metastasis: does it contribute to diagnosis or treatment ?

    International Nuclear Information System (INIS)

    Reddy, K.G.; Subbarao, K.; Kumaresan, K.; Murthy, V.S.; Kishore, L.T.

    1988-01-01

    A retrospective analysis of 47 patients with suspected bone metastases is performed to evaluate the role of bone scan in diagnosis or treatment and to compare radionuclide images with radiographs. Scan revealed solitary lesions in 27.7 per cent, multiple lesions in 44.7 per cent and was normal in 10.6 per cent of patients studied. In 11 patients the scan was +ve and x-ray was -ve and scan was false negative in one patient. Role of bone scan is evaluated by a scoring method. Scan contributed to correct diagnosis in 25.5 per cent, altered the management in 21.3 per cent of patients. However, scan by itself did not contribute to final management in 48.6 per cent of patients. Scan had misled the diagnosis because of false positive result in 4.3 per cent of patients. It is highlighted that though bone scan is non-specific, it has contributed considerably to the management of majority of patients. (author). 10 refs., 3 tabs., 4 figs

  7. Calibration of the NPL secondary standard radionuclide calibrator for the new 10R Schott, Type 1+ vials

    International Nuclear Information System (INIS)

    Baker, M.

    2005-01-01

    For many years, P6 vials have been used for the distribution of a wide range of diagnostic and therapeutic radioactive solutions. The activity measurements were performed in this geometry and, in time, the UK calibration system for nuclear medicine was based on this container as a standard. However, one major supplier of radiopharmaceuticals has replaced the P6 vial with the 10R Type 1+ Schott vial. As the dimensions of the new vial are different from those of the P6 vial and the responses of radionuclide calibrators are known to be container dependent, the need for re-calibration became apparent. Preliminary measurements made on some typical radionuclide calibrators for 125 I solution indicated a difference in response of about 10% between the two vials. The master ionisation chamber of the NPL secondary standard radionuclide calibrator has been re-calibrated and new calibration factors and volume correction factors for 10R Schott vials have been derived for the relevant medical radionuclides. The standard holder was also modified to accommodate the new larger vial. The complete list of factors and the method used to determine them is presented in this paper. The availability of these new factors will improve the quality of activity measurements in nuclear medicine, as calibration services can now be provided by NPL for the new container. These factors can also be employed for all commercial NPL secondary standard radionuclide calibrators (now known as the NPL-CRC and previously as the 671 or ISOCAL IV)

  8. Environmental effects of radionuclides - observations on natural ecosystems

    International Nuclear Information System (INIS)

    Copplestone, D.; Toal, M.E.; Johnson, M.S.; Jackson, D.; Jones, S.R.

    2000-01-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137 Cs, 238 Pu, 239+240 Pu and 241 Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d -1 ) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10 -3 mGy d -1 , 2.2x10 -3 mGy d -1 and 1.0x10 -3 mGy d -1 respectively. The values are at least three orders of magnitude lower than the 1 mGy d -1 level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  9. Environmental effects of radionuclides--observations on natural ecosystems.

    Science.gov (United States)

    Copplestone, D; Toal, M E; Johnson, M S; Jackson, D; Jones, S R

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides 137Cs, 238Pu, 239+240Pu and 241Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d(-1)) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0 x 10(-3) mGy d(-1), 2.2 x 10(-3) mGy d(-1) and 1.0 x 10(-3) mGy d(-1) respectively. The values are at least three orders of magnitude lower than the 1 mGy d(-1) level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed.

  10. Sources of anthropogenic radionuclides in the environment: a review

    International Nuclear Information System (INIS)

    Hu Qinhong; Weng Jianqing; Wang Jinsheng

    2010-01-01

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview on sources of anthropogenic radionuclides in the environment, as well as a brief discussion of salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current developments that have lead, or could potentially contribute, to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) uranium mining and milling; (5) commercial fuel reprocessing; (6) geological repository of high-level nuclear wastes that include radionuclides might be released in the future, and (7) nuclear accidents. Then, we briefly summarize the inventory of radionuclides 99 Tc and 129 I, as well as geochemical behavior for radionuclides 99 Tc, 129 I, and 237 Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment; biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  11. Assessment of the important radionuclides in nuclear waste

    International Nuclear Information System (INIS)

    Kerrisk, J.F.

    1985-10-01

    The relative importance of the various radionuclides contained in nuclear waste has been assessed by consideration of (1) the quantity of each radionuclide present, (2) the Environmental Protection Agency's release limits for radionuclides, (3) how retardation processes such as solubility and sorption affect radionuclie transport, and (4) the physical and chemical forms of radionuclides in the waste. Three types of waste were reviewed: spent fuel, high-level waste, and defense high-level waste. Conditions specific to the Nevada Nuclear Waste Storage Investigations project potential site at Yucca Mountain were used to describe radionuclide transport. The actinides Am, Pu, Np, and U were identified as the waste elements for which solubility and sorption data were most urgently needed. Other important waste elements were identified as Sr, Cs, C, Ni, Zr, Tc, Th, Ra, and Sn. Under some conditions, radionuclides of three elements (C, Tc, and I) may have high solubility and negligible sorption. The potential for transport of some waste elements (C and I) in the gas phase must also be evaluated for the Yucca Mountain Site. 12 refs., 17 tabs

  12. Drift-Scale Radionuclide Transport

    International Nuclear Information System (INIS)

    Houseworth, J.

    2004-01-01

    The purpose of this model report is to document the drift scale radionuclide transport model, taking into account the effects of emplacement drifts on flow and transport in the vicinity of the drift, which are not captured in the mountain-scale unsaturated zone (UZ) flow and transport models ''UZ Flow Models and Submodels'' (BSC 2004 [DIRS 169861]), ''Radionuclide Transport Models Under Ambient Conditions'' (BSC 2004 [DIRS 164500]), and ''Particle Tracking Model and Abstraction of Transport Process'' (BSC 2004 [DIRS 170041]). The drift scale radionuclide transport model is intended to be used as an alternative model for comparison with the engineered barrier system (EBS) radionuclide transport model ''EBS Radionuclide Transport Abstraction'' (BSC 2004 [DIRS 169868]). For that purpose, two alternative models have been developed for drift-scale radionuclide transport. One of the alternative models is a dual continuum flow and transport model called the drift shadow model. The effects of variations in the flow field and fracture-matrix interaction in the vicinity of a waste emplacement drift are investigated through sensitivity studies using the drift shadow model (Houseworth et al. 2003 [DIRS 164394]). In this model, the flow is significantly perturbed (reduced) beneath the waste emplacement drifts. However, comparisons of transport in this perturbed flow field with transport in an unperturbed flow field show similar results if the transport is initiated in the rock matrix. This has led to a second alternative model, called the fracture-matrix partitioning model, that focuses on the partitioning of radionuclide transport between the fractures and matrix upon exiting the waste emplacement drift. The fracture-matrix partitioning model computes the partitioning, between fractures and matrix, of diffusive radionuclide transport from the invert (for drifts without seepage) into the rock water. The invert is the structure constructed in a drift to provide the floor of the

  13. Effects on the pouch of different digestive tract reconstruction modes assessed by radionuclide scintigraphy

    OpenAIRE

    Li, Dong-Sheng; Xu, Hui-Mian; Han, Chun-Qi; Li, Ya-Ming

    2010-01-01

    AIM: To determine the effect of three digestive tract reconstruction procedures on pouch function, after radical surgery undertaken because of gastric cancer, as assessed by radionuclide dynamic imaging.

  14. Establishment of bases for joint study and cooperation on long-lived radionuclides transmutation between Korea and Russia

    International Nuclear Information System (INIS)

    Yoo, Jae Hyung; Lee, Byung Jik; Shim, Joon Bo; Choi, Chang Joo; Park, Won Seok; Song, Tae Young; Kim, Chang Kyu; Kil, Choong Sup

    2003-02-01

    The most important technical fields related to transmutation are partitioning of long-lived radionuclides and transmutation system to be used for converting them into short-lived or stable radionuclides. Technical cooperation between Korea and Russia is needed because Russia has an unequalled position in the fields of development of the fast reactors and pyrochemical processes around the world. The aim of this project is an establishment of bases for coordination on transmutation technology between Korea and Russia. State of the art of domestic and foreign countries upon partitioning of long-lived radionuclides, transmutation system and Gen IV development was summarized. Also, the 7th Korea-Russia joint coordination committee meeting and the 1st joint workshop were held as a result of this project. Technical fields and scheme on future cooperation between Korea and Russia were discussed and agreed in the course of the meetings

  15. Visualization of hypertrophied papillary muscle mimicking left ventricular mass on gated blood pool and T1-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Bunko, H.; Nakajima, K.; Tonami, N.; Asanoi, H.; Hisada, K.

    1981-01-01

    A sixty-year old man with acute myocardial infarction was incidentally found to have a hypertrophied anterolateral papillary muscle (ALPPM) of the left ventricle on gated blood pool (GBP) and T1-201 myocardial perfusion images. Hypertrophy of the ALPPM was visualized as a movable defect in the lateral basal area on GBP imaging throughout the cardiac cycle and on the TI-201 study as a radionuclide accumulating structure, consistent with the defect in the GBP. A combination of these findings may suggest the presence of a hypertrophied papillary muscle of the left ventricle

  16. Advances in process technology for eco-friendly phosphates by separation of radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Singh, H; Mukherjee, T K [Uranium and Rare Earths Extraction Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    Phosphates are used in the industry for fertilizers, industrial chemicals (detergents, water-treatment chemicals) and food-additives. The source of phosphates for the industry is rock-phosphate. Over 90% of phosphate rocks of the world are associated with uranium and its radioactive daughter products. Processing and use of phosphates is accompanied by radiation hazards. The concentration of radionuclides is low, but in view of large number of persons exposed to the hazards, the cumulative societal pollution load is high, and a matter of concern for international organisations. Chemical engineering techniques have been developed for the reduction of societal radiation hazard from the phosphates. In this paper, brief details of the process and developmental efforts in India are described. (author). 4 refs., 1 fig.

  17. Recent technologic developments on high-resolution beta imaging systems for quantitative autoradiography and double labeling applications

    CERN Document Server

    Barthe, N; Chatti, K; Coulon, P; Maitrejean, S; 10.1016/j.nima.2004.03.014

    2004-01-01

    Two novel beta imaging systems, particularly interesting in the field of radiopharmacology and molecular biology research, were developed these last years. (1) a beta imager was derived from research conducted by Pr Charpak at CERN. This parallel plate avalanche chamber is a direct detection system of beta radioactivity, which is particularly adapted for qualitative and quantitative autoradiography. With this detector, autoradiographic techniques can be performed with emitters such as /sup 99m/Tc because this radionuclide emits many low-energy electrons and the detector has a very low sensitivity to low-range gamma -rays. Its sensitivity (smallest activity detected: 0.007 cpm/mm/sup 2/ for /sup 3/H and 0.01 for /sup 14/C), linearity (over a dynamic range of 10/sup 4/) and spatial resolution (50 mu m for /sup 3/H or /sup 99m/Tc to 150 mu m for /sup 32/P or /sup 18/F ( beta /sup +/)) gives a real interest to this system as a new imaging device. Its principle of detection is based on the analysis of light emitte...

  18. Relationship between deep venous thrombosis and pulmonary embolism by radionuclide techniques in 150 patients

    International Nuclear Information System (INIS)

    Shi, R.F.; Wang, X.M.; Liu, X.J.; Fang, W.

    2002-01-01

    Objective: This study was to evaluate the relationship between deep venous thrombosis and pulmonary embolism assessed by radionuclide imaging. Methods: One hundred and fifty patients with pulmonary embolism from September 1997 to September 2001 were included. Pulmonary perfusion/ventilation imaging and deep venous radionuclide venography was performed in all patients. There were 87 men, and 63 women, with an average age 39±18 years. Of them, 26 underwent pulmonary arteriography. Eleven patients had X Ray phleography of lower extremities, 18 patients had Impedence plethymography (IPG), and 36 patients had lower limb ultrasound study. Results: Out of 150 patients with pulmonary embolism, 128 (85.5%) had lower limb venous pathological changes. Among them, 100 patients had risk factors of deep venous thrombosis (78.3%). 120 patients had proximal vein (80.0%). The agreement between radionuclide venography and X Ray phleography of lower extremities UCG and IPG was 90.9%, 70.2% and 80.0% respectively. Conclusions: Our results indicate that DVT was one of most important cause for acute pulmonary embolism, and thrombosis is mostly located in the proximal veins

  19. Quantitative assessment of valvular regurgitation using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Shi Rongfang

    1992-01-01

    Radionuclide ventriculography has been used to assess quantitatively the extent of mitral and aortic regurgitation in 70 patients and compared to echocardiography and the finding of surgery. Two radionuclide parameters were measured: regurgitant index (RI) = left ventricular stroke counts/right ventricular stroke counts; and regurgitant fraction (RF) = left ventricular stroke counts-right ventricular stroke counts/left ventricular stroke counts. In 28 patients without valvular heart disease, the RI was 1.10 ± 0.15 and Rf was 10.3 ± 15.0%, respectively. However, in patients with valvular regurgitation, the RI and RF were 3.41 ± 1.73 and 61.1 ± 21.2%, respectively. A good correlation was found between the results obtained by radionuclide techniques and the findings of surgery and doppler studies. The level of concordance between RI and surgical findings was 91.7%. Follow up studies in 10 patients after valvular replacement surgery showed the RI and RF return to normal. These data suggested that radionuclide ventriculography is very useful for quantitative assessment of valvular regurgitation

  20. An efficient adaptive arithmetic coding image compression technology

    International Nuclear Information System (INIS)

    Wang Xing-Yuan; Yun Jiao-Jiao; Zhang Yong-Lei

    2011-01-01

    This paper proposes an efficient lossless image compression scheme for still images based on an adaptive arithmetic coding compression algorithm. The algorithm increases the image coding compression rate and ensures the quality of the decoded image combined with the adaptive probability model and predictive coding. The use of adaptive models for each encoded image block dynamically estimates the probability of the relevant image block. The decoded image block can accurately recover the encoded image according to the code book information. We adopt an adaptive arithmetic coding algorithm for image compression that greatly improves the image compression rate. The results show that it is an effective compression technology. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  1. Specific processes in solvent extractiotn of radionuclide complexes

    International Nuclear Information System (INIS)

    Macasek, F.

    1982-01-01

    The doctoral thesis discusses the consequences of the radioactive beta transformation in systems liquid-liquid and liquid-ion exchanger, and the effect of the chemical composition of liquid-liquid systems on the distribution of radionuclide traces. A model is derived of radiolysis in two-phase liquid-liquid systems used in nuclear chemical technology. The obtained results are used to suggest the processing of radioactive wastes using the Purex process. For solvent extraction the following radionuclides were used: 59 Fe, 95 Zr- 95 Nb, 99 Mo, sup(99m)Tc, 99 Tc, 103 Pd, 137 Cs, 141 Ce, 144 Ce- 144 Pr, 234 Th, and 233 Pa. Extraction was carried out at laboratory temperature. 60 Co was used as the radiation source. Mainly scintillation spectrometry equipment was used for radiometric analysis. (E.S.)

  2. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Howard, B.J.; Kennedy, V.H.; Nelson, A.

    1983-06-01

    A bibliographical database has been developed to provide quick access to research and background literature in the field of radioecology. This is a development of an earlier database described by Nelson (Bocock 1981). ITE's particular fields of interest have led to a subject bias in the bibliography towards studies in Cumbria, especially those concerned with radionuclides originating from the reprocessing plant at Sellafield, and towards ecological research studies that are complementary to radionuclide studies. Other subjects covered, include the chemistry of radionuclides, budgets and transfers within ecosystems and techniques for the analysis of environmental samples. ITE's research objectives have led to the establishment of a specialized database which is intended to complement rather than compete with the large international databases made available by suppliers such as IRS-DIALTECH or DIALOG. Currently the database holds about 1900 references which are stored on a 2 1/2 megabyte hard disk on a Digital PDP11/34 computer operating under a time shared system. The references follow a standard format. (author)

  3. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  4. 3D integration technologies for imaging applications

    International Nuclear Information System (INIS)

    Moor, Piet de

    2008-01-01

    The aim of this paper is to give an overview of micro-electronic technologies under development today, and how they are impacting on the radiation detection and imaging of tomorrow. After a short introduction, the different enabling technologies will be discussed. Finally, a few examples of ongoing developments at IMEC on advanced detector systems will be given

  5. Recent advances in imaging technologies in dentistry

    Institute of Scientific and Technical Information of China (English)

    Naseem; Shah; Nikhil; Bansal; Ajay; Logani

    2014-01-01

    Dentistry has witnessed tremendous advances in all its branches over the past three decades. With these advances, the need for more precise diagnostic tools,specially imaging methods, have become mandatory.From the simple intra-oral periapical X-rays, advanced imaging techniques like computed tomography, cone beam computed tomography, magnetic resonance imaging and ultrasound have also found place in modern dentistry. Changing from analogue to digital radiography has not only made the process simpler and faster but also made image storage, manipulation(brightness/contrast, image cropping, etc.) and retrieval easier. The three-dimensional imaging has made the complex cranio-facial structures more accessible for examination and early and accurate diagnosis of deep seated lesions. This paper is to review current advances in imaging technology and their uses in different disciplines of dentistry.

  6. Radionuclide concentrations in white sturgeon from the Columbia River

    International Nuclear Information System (INIS)

    Dauble, D.D.; Price, K.R.; Poston, T.M.

    1993-11-01

    The objectives of this study were to (1) review and summarize historical data on radionuclide concentrations in white sturgeon from the Columbia River, (2) determine present-day radionuclide tissue burdens from different locations in the Columbia River, and (3) compare historical data with current data. We first reviewed and summarized the historical literature on radionuclide concentrations in white sturgeon from the Hanford Reach. Field studies were then conducted to evaluate the relationship among sample locations, age/length of white sturgeon, and present radionuclide tissue burdens. Results and comparisons are discussed in the remainder of this report

  7. Radionuclide transit in esophageal varices

    International Nuclear Information System (INIS)

    Yeh, S.H.; Wang, S.J.; Wu, L.C.; Liu, R.S.; Tsai, Y.T.; Chiang, T.T.

    1985-01-01

    This study assessed esophageal motility in patients with esophageal varices by radionuclide transit studies. Data were acquired in list mode after an oral dose of 0.5 mCi Tc-99m sulfur colloid in 10 ml of water in the supine position above a low-energy all-purpose collimator of a gamma camera. The condensed image (CI) superimposed with a centroid curve was also produced in each case. Twenty-five normal subjects (N) and 32 patients (pts) with esophageal varices by endoscopy (large varices in Grades IV and V in 8 and small varices in Grade III or less in 24) were studied. TMTT, RTT, RF, and RI were all significantly increased in pts as compared to N. Especially, the transit time for the middle third (6.7 +- 2.6 sec vs 3.5 +- 0.9 sec in N, rho < 0.005) had the optimal sensitivy and specificity of 88% each at the cutoff value of 4.2 sec as determined by ROC analysis. In summary, radionuclide transit disorders occur in the majority of pts with esopageal varices. The middle RTT and CI are both optimal in sensitivity and specificity for detecting the abnormalities

  8. Geomorphological applications of environmental radionuclides

    International Nuclear Information System (INIS)

    Quine, T.A.; Walling, D.

    1998-01-01

    Geomorphologists have shown increasing interest in environmental radionuclides since pioneering studies by Ritchie and McHenry in the USA and Campbell, Longmore and Loughran in Australia. Environmental radionuclides have attracted this interest because they provide geomorphologists with the means to trace sediment movement within the landscape. They, therefore, facilitate investigation of subjects at the core of geomorphology, namely the rates and patterns of landscape change. Most attention has been focussed on the artificial radionuclide caesium-137 ( 137 Cs) but more recently potential applications of the natural radionuclides lead-210 ( 210 Pb) and beryllium-7( 7 Be) have been investigated (Walling et al., 1995; Wallbrink and Murray, 1996a, 1996b). The origin, characteristics and applications of these radionuclides are summarised. These radionuclides are of value as sediment tracers because of three important characteristics: a strong affinity for sediment; a global distribution and the possibility of measurement at low concentration. Geomorphological applications of environmental radionuclides provide unique access to detailed qualitative data concerning landscape change over a range of timescales

  9. Application of computer-assisted imaging technology in human musculoskeletal joint research

    Directory of Open Access Journals (Sweden)

    Xudong Liu

    2014-01-01

    Full Text Available Computer-assisted imaging analysis technology has been widely used in the musculoskeletal joint biomechanics research in recent years. Imaging techniques can accurately reconstruct the anatomic features of the target joint and reproduce its in vivo motion characters. The data has greatly improved our understanding of normal joint function, joint injury mechanism, and surgical treatment, and can provide foundations for using reverse-engineering methods to develop biomimetic artificial joints. In this paper, we systematically reviewed the investigation of in vivo kinematics of the human knee, shoulder, lumber spine, and ankle using advanced imaging technologies, especially those using a dual fluoroscopic imaging system (DFIS. We also briefly discuss future development of imaging analysis technology in musculoskeletal joint research.

  10. Radionuclide Imaging of Musculoskeletal Injuries in Athletes with Negative Radiographs.

    Science.gov (United States)

    Nagle, C E; Freitas, J E

    1987-06-01

    In brief: Radionuclide bone scans can be useful in the diagnostic evaluation of musculoskeletal injuries in athletes. Bone scans can detect shinsplints, stress fractures, and muscle injuries before they are detectable on radiographs. Prognosis can be accurately assessed, allowing appropriate treatment to proceed without delay. The authors discuss the use of bone scans and identify musculoskeletal injuries that are associated with specific sports, such as stress fracture of the femur (soccer), tibia (running), scapula (gymnastics), and pars interarticularis (football or lacrosse).

  11. Adaptive Optics Technology for High-Resolution Retinal Imaging

    Science.gov (United States)

    Lombardo, Marco; Serrao, Sebastiano; Devaney, Nicholas; Parravano, Mariacristina; Lombardo, Giuseppe

    2013-01-01

    Adaptive optics (AO) is a technology used to improve the performance of optical systems by reducing the effects of optical aberrations. The direct visualization of the photoreceptor cells, capillaries and nerve fiber bundles represents the major benefit of adding AO to retinal imaging. Adaptive optics is opening a new frontier for clinical research in ophthalmology, providing new information on the early pathological changes of the retinal microstructures in various retinal diseases. We have reviewed AO technology for retinal imaging, providing information on the core components of an AO retinal camera. The most commonly used wavefront sensing and correcting elements are discussed. Furthermore, we discuss current applications of AO imaging to a population of healthy adults and to the most frequent causes of blindness, including diabetic retinopathy, age-related macular degeneration and glaucoma. We conclude our work with a discussion on future clinical prospects for AO retinal imaging. PMID:23271600

  12. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  13. Generator for radionuclide

    International Nuclear Information System (INIS)

    Weisner, P.S.; Forrest, T.R.F.

    1985-01-01

    This invention provides a radionuclide generator of the kind in which a parent radionuclide, adsorbed on a column of particulate material, generates a daughter radionuclide which is periodically removed from the column. This invention is particularly concerned with technetium generators using single collection vials. The generator comprises a column, a first reservoir for the eluent, a second reservoir to contain the volume of eluent required for a single elution, and means connecting the first reservoir to the second reservoir and the second reservoir to the column. Such a generator is particularly suitable for operation by vacuum elution

  14. Production of radionuclides and preparation of labelled compounds. Nuclear chemical technology

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    A general review is presented of methods of producing radionuclide preparations and labelled compounds, such as their production from natural raw materials, from a nuclear reactor, a particle accelerator, and using radioisotope generators. Also described are the fundamental kinetic relations of nuclear reactions. Basic methods are surveyed of obtaining labelled compounds by chemical synthesis, biosynthesis, exchange reactions, recoil reactions, by the Wilzbach method and the Szillard-Chalmers reaction. (L.K.)

  15. Process for encapsulating radionuclides

    International Nuclear Information System (INIS)

    Brownell, L.E.; Isaacson, R.E.

    1976-01-01

    Radionuclides are immobilized in virtually an insoluble form by reacting at a temperature of at least 90 0 C as an aqueous alkaline mixture having a solution pH of at least 10, containing a source of silicon, the radionuclide waste, and a metal cation. The molar ratio of silicon to the metal cation is on the order of unity to produce a gel from which complex metalosilicates crystallize to entrap the radionuclides within the resultant condensed crystal lattice. The product is a silicious stone-like material which is virtually insoluble and nonleachable in alkaline or neutral environment. One embodiment provides for the formation of the complex metalo-silicates, such as synthetic pollucite, by gel formation with subsequent calcination to the solid product; another embodiment utilizes a hydrothermal process, either above ground or deep within basalt caverns, at greater than atmospheric pressures and a temperature between 90 and 500 0 C to form complex metalo-silicates, such as strontium aluminosilicate. Another embodiment provides for the formation of complex metalo-silicates, such as synthetic pollucite, by slurrying an alkaline mixture of bentonite or kaolinite with a source of silicon and the radionuclide waste in salt form. In each of the embodiments a mobile system is achieved whereby the metalo-silicate constituents reorient into a condensed crystal lattice forming a cage structure with the condensed metalo-silicate lattice which completely surrounds the radionuclide and traps the radionuclide therein; thus rendering the radionuclide virtually insoluble

  16. Assessment of radionuclide contents in food in Hong Kong

    International Nuclear Information System (INIS)

    Yu, K.N.; Mao, S.Y.

    1999-01-01

    Baseline values of concentrations of the natural radionuclides ( 238 U, 226 Ra, 228 Ra/ 232 Th, 210 Pb) and artificial radionuclides ( 137 Cs, 60 Co) in food and drinks (tap water, milk, and water-based drinks) were determined by gamma spectroscopy. All food and drinks were found to contain detectable 40 K contents: 0.1 to 160 Bq Kg -1 for food and 0.006 to 61 Bq L -1 for drinks. Most of the other natural radionuclides in solid food were found to have contents below the minimum detectable activities (MDA). More samples in the leafy vegetable, tomato, carrot and potato categories contained detectable amounts of 228 Ra than the meat, cereal, and fish categories, with concentrations up to 1.2 Bq kg -1 for the former categories and 0.35 Bq kg -1 for the latter categories. The 238 U and 226 Ra radionuclides were detectable in most of the water-based drink samples, and the 228 Ra and 210 Pb radionuclides were detectable in fewer water-based drink samples. The 137 Cs contents in solid food were detectable in most of the solid food samples (reaching 0.59 Bq kg -1 ), but in drinks the 137 Cs contents were very low and normally lower than the MDA values. Nearly all the 60 Co contents in food and drinks were below the MDA values and their contents were below those of 137 Cs

  17. Optical Imaging of Ionizing Radiation from Clinical Sources.

    Science.gov (United States)

    Shaffer, Travis M; Drain, Charles Michael; Grimm, Jan

    2016-11-01

    Nuclear medicine uses ionizing radiation for both in vivo diagnosis and therapy. Ionizing radiation comes from a variety of sources, including x-rays, beam therapy, brachytherapy, and various injected radionuclides. Although PET and SPECT remain clinical mainstays, optical readouts of ionizing radiation offer numerous benefits and complement these standard techniques. Furthermore, for ionizing radiation sources that cannot be imaged using these standard techniques, optical imaging offers a unique imaging alternative. This article reviews optical imaging of both radionuclide- and beam-based ionizing radiation from high-energy photons and charged particles through mechanisms including radioluminescence, Cerenkov luminescence, and scintillation. Therapeutically, these visible photons have been combined with photodynamic therapeutic agents preclinically for increasing therapeutic response at depths difficult to reach with external light sources. Last, new microscopy methods that allow single-cell optical imaging of radionuclides are reviewed. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. The fate and importance of radionuclides produced in nuclear events

    Energy Technology Data Exchange (ETDEWEB)

    Shore, B; Anspaugh, L; Chertok, R; Gofman, J; Harrison, F; Heft, R; Koranda, J; Ng, Y; Phelps, P; Potter, G; Tamplin, A [Lawrence Radiation Laboratory, University of California, Livermore, CA (United States)

    1969-07-01

    Some of the major program at the Bio-Medical Division concerned with the fate and importance of the fission products, the radionuclides induced in the device materials, the radionuclides induced in the environment surrounding the device, and the tritium produced in Plowshare cratering events will be discussed. These programs include (1) critical unknowns in predicting organ and body burdens from radionuclides produced in cratering events; (2) the analysis with a high-resolution solid state gamma ray spectrometer of radionuclides in complex biological and environmental samples; (3) the characterization of radioactive particles from cratering detonation; (4) the biological availability to beagles, pigs and goats of radionuclides in Plowshare debris; (5) the biological availability to aquatic animals of radionuclides in Plowshare and other nuclear debris and the biological turnover of critical nuclides in specific aquatic animals; (6) the biological availability of Plowshare and other nuclear debris radionuclides to dairy cows and the transplacental transport of debris radionuclides in the dairy cow; (7) the persistence and behavior of radionuclides, particularly tritium, at sites of Plowshare and other nuclear detonations; and (8) somatic effects of Low Dose Radiation: Chromosome studies. (author)

  19. The fate and importance of radionuclides produced in nuclear events

    International Nuclear Information System (INIS)

    Shore, B.; Anspaugh, L.; Chertok, R.; Gofman, J.; Harrison, F.; Heft, R.; Koranda, J.; Ng, Y.; Phelps, P.; Potter, G.; Tamplin, A.

    1969-01-01

    Some of the major program at the Bio-Medical Division concerned with the fate and importance of the fission products, the radionuclides induced in the device materials, the radionuclides induced in the environment surrounding the device, and the tritium produced in Plowshare cratering events will be discussed. These programs include (1) critical unknowns in predicting organ and body burdens from radionuclides produced in cratering events; (2) the analysis with a high-resolution solid state gamma ray spectrometer of radionuclides in complex biological and environmental samples; (3) the characterization of radioactive particles from cratering detonation; (4) the biological availability to beagles, pigs and goats of radionuclides in Plowshare debris; (5) the biological availability to aquatic animals of radionuclides in Plowshare and other nuclear debris and the biological turnover of critical nuclides in specific aquatic animals; (6) the biological availability of Plowshare and other nuclear debris radionuclides to dairy cows and the transplacental transport of debris radionuclides in the dairy cow; (7) the persistence and behavior of radionuclides, particularly tritium, at sites of Plowshare and other nuclear detonations; and (8) somatic effects of Low Dose Radiation: Chromosome studies. (author)

  20. Potato production on private plots contaminated by radionuclides

    International Nuclear Information System (INIS)

    Bogdevitch, I.; Tarasiuk, S.

    2004-01-01

    technology was developed and tested by stakeholders on 130 plots of Stolyn and Slavgorod districts during 2001-2003. The results have shown that potato yield in experiment was increased up to 35 t ha -1 or in 1.6 times to the control with usual technology. The 1 euro invested to the potato experiment provided 1.5-2.0 euros of net return on the average. The careful testing of technology by some participants allowed to reduce the 137 Cs and 90 Sr accumulation in potatoes up to 50-70% and the nitrate concentration in 1.5-2.6 times to the control. Presumably the 90 Sr concentration on plots contaminated by radionuclide and nitrate concentration in tuber should be permanently controlled. (author)

  1. Radionuclides distribution in artificial reservoir V-17 (old swamp)

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmenkova, N. [Vernadsky Institute of geochemistry and analytical chemistry RAS (Russian Federation); Vlasova, I.; Sapozhnikov, Y.; Kalmykov, S. [Lomonosov MSU, Chemistry Dep. (Russian Federation); Pryakhin, E. [Urals Research center for radiation medicine (Russian Federation); Ivanov, I. [FSUE Mayak PA (Russian Federation)

    2014-07-01

    Reservoir V-17 (Old Swamp) was formed as a result of the construction of dams in 1952 and 1954 (MAYAK Production Association),located in a natural depression relief. Intermediate level liquid radioactive wastes (ILLW) have been discharged to this reservoir since 1949. The water surface area of the lake is 0.13 km{sup 2} with the volume of 0.36 Mm{sup 3}. The maximum depth is 6.5 m with the average value of 2.8 m. Among 74 PBq deposited to the reservoir, the major portion is concentrated in the bottom sediments (as determined in 2007). The aim of this study is to determine radionuclide distribution among abiotic and biotic aquatic components, that includes study of various radionuclides distribution between water and bottom sediments, their speciation and evaluation of condition of zooplankton community. As a result of field research at the reservoir, 4 sampling locations were chosen from which bottom sediments, water samples and some hydrobionts were collected. Pore waters were separated from the wet sediments by high-speed centrifugation. All samples were analyzed by gamma spectrometry using HPGe detector Canberra GR 3818.The radioactivity of tritium in the pore and lake waters was determined by liquid-scintillation spectrometry. The strontium-90 was detected by Cherenkov counting of the daughter {sup 90}Y. The preliminary data show for sediments samples: for {sup 137}Cs amount varies from 75,5 KBq/g to 232 KBq/g, {sup 154}Eu - from 460 to 990 Bq/g, {sup 241}Am - from 1 to 4 KBq/g, {sup 134}Cs - from 50 to 220 Bq/g; for water samples: large contribution from strontium-90 and tritium (varies from 2 to 25 Bq/g). Pore water contains medium amount of radionuclides between sediments and water samples. For {sup 137}Cs varies between 160 to 1100 Bq/g, {sup 154}Eu - from 0,1 to 0,3 Bq/g, {sup 241}Am - from 0,3 to 11 Bq/g, {sup 134}Cs - from 0,1 to 1,7 Bq/g. Variation depends on the sampling place. Activity distribution among hydrobionts was studied by digital Radiography

  2. The application of radionuclides in medicine

    International Nuclear Information System (INIS)

    Boyd, R.E.; Murray, I.P.C.; Sorby, P.J.; Hetherington, E.L.R.

    1977-01-01

    The authors of this article describe the history of nuclear medicine from its beginning at the end of the 19th century when radioactivity was discovered, basic considerations which describe briefly the properties of radionuclides with special reference to the ones which are suited to medical applications and in general terms the diagnostic techniques that are current. The article also includes a segment on the radionuclide technetium 99m, explaining why it is ideal for organ imaging and how it is utilised in a range of radiopharmaceuticals for investigations into many areas of the human body. The radiation risk to the patient, including tabulated radiation exposures for a few of the more common nuclear medicine studies, is dealt with. The article explains that a greater risk to life from not having the test performed is used as the criterion for justifying whether a nuclear medicine procedure is performed or not. The article finally describes the scope of the techniques and the areas of the body which are routinely examined and are exemplified with numerous illustrations. (J.R.)

  3. Radionuclides and the normal bone scan

    International Nuclear Information System (INIS)

    Mettler, F.A. Jr.; Monsein, L.; Rosenberg, R.D.

    1988-01-01

    Recently, Eisenhut and co-workers have described development of iodine-131 labeled diphosphonates for palliative treatment of bone metastases. The compound labeled was alpha-amino (4-hydroxybenzylidene) diphosphonate (BDP3). Other beta-emitting radionuclides have been used for treatment of intractable pain secondary to bone metastases. These include strontium-89, which has some difficulties, particularly in terms of disposal of the excretions due to the long physical half-life of the life of the radionuclide. Yttrium-90 has also been used but has a relatively high hepatic uptake. Phosphorus-32 labeled compounds have also been used. Although palliation has been described, bone marrow depression has also occurred. Rhenium-186 also has been suggested, however, high renal uptake is a problem. At present, the iodine-131 labeled BDP3 appears to be the best of the available therapeutic radiopharmaceuticals. One of the major disadvantages in use of this compound is the production of gamma photons. While undesirable from a dosimetry viewpoint, gamma photons do, however, permit imaging if desired

  4. Radionuclide content in the Upper Vistula River sediments in a coal mining region in Poland (east-central Europe)

    International Nuclear Information System (INIS)

    Jasinska, M.; Mietelski, J.W.; Pociask-Karteczka, J.

    1998-01-01

    Hard coal mining activity is one of the Technologically Enhanced Natural Radiation sources introduced more than a hundred years ago in the southern part of Poland. This study of radionuclides (K-40, Ra-226, Ra-228) in river sediments showed the principal factors determining the specific activity of radionuclides are distance from mines and sorption by clay particles in river sediments. The K-40 specific activity varies between 185 and 595 Bq/kg. The highest Ra-228 and Ra-226 specific activities, 280-610 and 205-415 Bq/kg, respectively, were detected in sediments of the Vistula in the vicinity of Silesia region. 7 refs., 1 fig., 3 tabs

  5. A new concept for medical imaging centered on cellular phone technology.

    Directory of Open Access Journals (Sweden)

    Yair Granot

    2008-04-01

    Full Text Available According to World Health Organization reports, some three quarters of the world population does not have access to medical imaging. In addition, in developing countries over 50% of medical equipment that is available is not being used because it is too sophisticated or in disrepair or because the health personnel are not trained to use it. The goal of this study is to introduce and demonstrate the feasibility of a new concept in medical imaging that is centered on cellular phone technology and which may provide a solution to medical imaging in underserved areas. The new system replaces the conventional stand-alone medical imaging device with a new medical imaging system made of two independent components connected through cellular phone technology. The independent units are: a a data acquisition device (DAD at a remote patient site that is simple, with limited controls and no image display capability and b an advanced image reconstruction and hardware control multiserver unit at a central site. The cellular phone technology transmits unprocessed raw data from the patient site DAD and receives and displays the processed image from the central site. (This is different from conventional telemedicine where the image reconstruction and control is at the patient site and telecommunication is used to transmit processed images from the patient site. The primary goal of this study is to demonstrate that the cellular phone technology can function in the proposed mode. The feasibility of the concept is demonstrated using a new frequency division multiplexing electrical impedance tomography system, which we have developed for dynamic medical imaging, as the medical imaging modality. The system is used to image through a cellular phone a simulation of breast cancer tumors in a medical imaging diagnostic mode and to image minimally invasive tissue ablation with irreversible electroporation in a medical imaging interventional mode.

  6. Diagnosis of secondary hyperparathyroidism with 99mTc-MIBI/131I parathyroid imaging in chronic renal failure

    International Nuclear Information System (INIS)

    Tang Anwu; Luo Yaowu; Wu Yongkang; Pan Jianzhong; Ji Liangyuan

    1995-01-01

    20 chronic renal failure (CRF) patients and 15 normals were investigated with radionuclide parathyroid imaging and parathyroid hormone (PTH) RIA measurement for the detection of hyperparathyroidism. The serum PTH concentrations were 800.47 +- 665.25 pmol/L and 82.81 +- 13.79 pmol/L in two groups respectively. The radionuclide parathyroid images revealed that 1∼4 enlarged parathyroid glands were visualized in the CRF patients, none in the normals

  7. Vertical soil migration of radionuclide fallout from the Chernobyl' accident

    International Nuclear Information System (INIS)

    Silant'ev, A.N.; Shkuratova, I.G.; Bobovnikova, T.I.

    1989-01-01

    The most suitable model for describing the behavior of radionuclide fallout on a soil surface is quasidiffusion transfer with directional transfer taken into account. The parameter values for this have been determined previously and are supplemented by the results of this work. To investigate the initial radionuclide distribution along the soil profile, monolithic soil samples 5 cm thick were taken in June-September 1986 in areas which had been subjected to contamination due to the Chernobyl' accident. The samples taken were cut up into layers. The first layer, 0.5 cm thick, was cut off from the surface of the soil monolith together with the grass. The next layer cut off was also 0.5 cm thick. Then two layers, each 1 cm in thickness, were cut off. The thickness of the last layer was 2 cm. The vertical distribution of radionuclides along the soil profile which was examined may be called the initial distribution, which will then change due to nonimmediate migration of radionuclides in the soil. Based on the research which has been performed, the following conclusions may be drawn. One portion of the radionuclides resulting from fallout is trapped by plant cover, while the other enters immediately into the soil. For a thick plant covering, about 80% of the radionuclide fallout is sorbed by the grass; for sparse cover, about 40%. The radionuclides entering the soil along with rainwater penetrate into the soil depths, producing contamination which falls off exponentially with depth. The exponent index is close to 1 cm -1 . In a forest, the main amount of radionuclide fallout is trapped by litter. Approximately 10% of the contamination fallout penetrates beneath the litter

  8. SPECT/CT: can it be helpful in the evaluation of the distribution of the radionuclide in the joint following radio-synovectomy?

    International Nuclear Information System (INIS)

    Ozulker, F.; Kucukoz Uzun, A.; Ozulker, T.

    2015-01-01

    Full text of publication follows. Planar control scintigraphies have been used for the detection of any possible extra articular leakage after radio-synovectomy in patients with haemophilic arthropathy. In this study we aimed at assessing whether utilization of SPECT-CT for the same purpose can provide additional information. Patients who fulfilled the following prerequisites were included for radio synovectomy application: (1) more than four hemorrhagic episodes in six months, (2) at least a Stage II haemophilic arthropathy according to the classification of Arnold and Haltering, and (3) persistent synovitis. Six male patients (5 hemophilia A, 1 hemophilia B) who suffered from haemophilic arthropathy with a mean age of 10.5 (range between 8-15) were included in this study. We administered 148-185 MBq Yttrium 90 silicate (Y-90) to 5 knee joints, 74 MBq Rhenium 186 (Re-186) to 1 elbow joint and 74 MBq Re-186 to two ankle joints of these patients. The median number of bleedings into the target joints was 10.1 ± 1.4 in the six months prior to the procedure. All patients were admitted to the hospital and treated with factor replacement so as to raise the factor level of the patient to 80% the following morning and 50% for three days thereafter. The effusion in the joint was evacuated before the injection of the radiocolloid. Intra-articular injections in ankle and elbow joints were done under fluoroscopic guidance. The joint was moved rapidly a few times to distribute the radiocolloid, after which a plaster of paris cast was applied for 72 hours. One hour after the RS, planar images of the treated joints and the regional lymph nodes were obtained with gamma camera and SPECT-BT acquisitions were obtained from treated joints to confirm the appropriate distribution of the radionuclide in the joint. Distribution of the radionuclide in joint spaces was normal and we haven't encountered any extra articular leakage. In one patient there was loculation at activity in

  9. Automated method and system for the alignment and correlation of images from two different modalities

    Science.gov (United States)

    Giger, Maryellen L.; Chen, Chin-Tu; Armato, Samuel; Doi, Kunio

    1999-10-26

    A method and system for the computerized registration of radionuclide images with radiographic images, including generating image data from radiographic and radionuclide images of the thorax. Techniques include contouring the lung regions in each type of chest image, scaling and registration of the contours based on location of lung apices, and superimposition after appropriate shifting of the images. Specific applications are given for the automated registration of radionuclide lungs scans with chest radiographs. The method in the example given yields a system that spatially registers and correlates digitized chest radiographs with V/Q scans in order to correlate V/Q functional information with the greater structural detail of chest radiographs. Final output could be the computer-determined contours from each type of image superimposed on any of the original images, or superimposition of the radionuclide image data, which contains high activity, onto the radiographic chest image.

  10. Environmental effects of radionuclides - observations on natural ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Copplestone, D. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom). E-mail: copplest at liv.ac.uk; Toal, M.E.; Johnson, M.S. [Industrial Ecology Research Centre, School of Biological Sciences, University of Liverpool, Liverpool L69 3BX (United Kingdom); Jackson, D.; Jones, S.R. [Westlakes Scientific Consulting, Princess Royal Building, Westlakes Science and Technology Park, Moor Row, Cumbria CA24 3LN (United Kingdom)

    2000-03-01

    To better quantify risk to non-human species from exposure to environmental radioactivity, understanding of the behaviour of radionuclides in the biosphere needs to be increased. This study outlines current thinking on ecological risk assessment (ERA) methodology and applies the indicator species or critical groups approach to biota inhabiting a semi-natural coniferous woodland contaminated with the radionuclides {sup 137}Cs, {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am. The majority of these radionuclides originate from routine aerial emissions from the nuclear fuel reprocessing plant at BNFL, Sellafield, Cumbria, UK. Radionuclide activity concentrations have been determined in biota from the woodland and estimates of absorbed dose rates (mGy d{sup -1}) have been calculated using the dosimetric models outlined. Dose rates to the key indicator species, Oniscus asellus, Carabus violaceous and Apodemus sylvaticus (detritivorous invertebrate, predatory invertebrate and the granivorous wood mouse) have been determined at 3.0x10{sup -3} mGy d{sup -1}, 2.2x10{sup -3} mGy d{sup -1} and 1.0x10{sup -3} mGy d{sup -1} respectively. The values are at least three orders of magnitude lower than the 1 mGy d{sup -1} level below which no observable effects on populations in a terrestrial ecosystem are thought to occur. Limitations of this approach are discussed. (author)

  11. Radionuclide transfer from mother to embryo

    International Nuclear Information System (INIS)

    Toader, M.; Vasilache, R.A.; Scridon, R.; Toader, M.L.

    1998-01-01

    The transfer of radionuclides from mother to embryo is still a matter of high interest. Therefore, the relation was investigated between the amount of radionuclides in the embryo and the dietary intake of the mother, this for two scenarios: a recurrent intake of variable amounts of radionuclides, and a long-term intake of a relatively constant amount of radionuclides, the radionuclide being 137 Cs. In the first case, the amount of radionuclides present in the embryo increases with the age of the embryo and with the intake of the mother. In the second case, no correlation could be found between the age of the embryo and its radioactive content; only the correlation between the intake of the mother and the radionuclide content of the embryo remained. (A.K.)

  12. Robot Vision to Monitor Structures in Invisible Fog Environments Using Active Imaging Technology

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seungkyu; Park, Nakkyu; Baik, Sunghoon; Choi, Youngsoo; Jeong, Kyungmin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    Active vision is a direct visualization technique using a highly sensitive image sensor and a high intensity illuminant. Range-gated imaging (RGI) technique providing 2D and 3D images is one of emerging active vision technologies. The RGI technique extracts vision information by summing time sliced vision images. In the RGI system, objects are illuminated for ultra-short time by a high intensity illuminant and then the light reflected from objects is captured by a highly sensitive image sensor with the exposure of ultra-short time. The RGI system provides 2D and 3D image data from several images and it moreover provides clear images from invisible fog and smoke environment by using summing of time-sliced images. Nowadays, the Range-gated (RG) imaging is an emerging technology in the field of surveillance for security applications, especially in the visualization of invisible night and fog environment. Although RGI viewing was discovered in the 1960's, this technology is, nowadays, more and more applicable by virtue of the rapid development of optical and sensor technologies, such as highly sensitive imaging sensor and ultra-short pulse laser light. In contrast to passive vision systems, this technology enables operation even in harsh environments like fog and smoke. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been demonstrated 3D imaging based on range-gated imaging. In this paper, a robot system to monitor structures in invisible fog environment is developed using an active range-gated imaging technique. The system consists of an ultra-short pulse laser device and a highly sensitive imaging sensor. The developed vision system is carried out to monitor objects in invisible fog environment. The experimental result of this newly approach vision system is described in this paper. To see invisible objects in fog

  13. Robot Vision to Monitor Structures in Invisible Fog Environments Using Active Imaging Technology

    International Nuclear Information System (INIS)

    Park, Seungkyu; Park, Nakkyu; Baik, Sunghoon; Choi, Youngsoo; Jeong, Kyungmin

    2014-01-01

    Active vision is a direct visualization technique using a highly sensitive image sensor and a high intensity illuminant. Range-gated imaging (RGI) technique providing 2D and 3D images is one of emerging active vision technologies. The RGI technique extracts vision information by summing time sliced vision images. In the RGI system, objects are illuminated for ultra-short time by a high intensity illuminant and then the light reflected from objects is captured by a highly sensitive image sensor with the exposure of ultra-short time. The RGI system provides 2D and 3D image data from several images and it moreover provides clear images from invisible fog and smoke environment by using summing of time-sliced images. Nowadays, the Range-gated (RG) imaging is an emerging technology in the field of surveillance for security applications, especially in the visualization of invisible night and fog environment. Although RGI viewing was discovered in the 1960's, this technology is, nowadays, more and more applicable by virtue of the rapid development of optical and sensor technologies, such as highly sensitive imaging sensor and ultra-short pulse laser light. In contrast to passive vision systems, this technology enables operation even in harsh environments like fog and smoke. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been demonstrated 3D imaging based on range-gated imaging. In this paper, a robot system to monitor structures in invisible fog environment is developed using an active range-gated imaging technique. The system consists of an ultra-short pulse laser device and a highly sensitive imaging sensor. The developed vision system is carried out to monitor objects in invisible fog environment. The experimental result of this newly approach vision system is described in this paper. To see invisible objects in fog

  14. Exposure-dose research for radionuclides in natural gas

    International Nuclear Information System (INIS)

    McNelis, D.N.; Patzer, R.G.

    1969-01-01

    The fate determination of specific radionuclides in natural gas stimulated by underground engineering applications is being examined. An experimental program, now in its initial stages, is using gas artificially labeled with krypton-85 and tritium under simulated domestic situations. The following topics are being investigated in this study: 1. The concentration of the radionuclides in a gas-heated home. 2. The build-up of contamination on appliances in the kitchen environment. 3. The concentration in foods as a function of radionuclide, food type and preparation. 4. The maximum exposure plausible under specified conditions. (author)

  15. Exposure-dose research for radionuclides in natural gas

    Energy Technology Data Exchange (ETDEWEB)

    McNelis, D N; Patzer, R G [Southwestern Radiological Health Laboratory, U.S. Public Health Service, Las Vegas, NV (United States)

    1969-07-01

    The fate determination of specific radionuclides in natural gas stimulated by underground engineering applications is being examined. An experimental program, now in its initial stages, is using gas artificially labeled with krypton-85 and tritium under simulated domestic situations. The following topics are being investigated in this study: 1. The concentration of the radionuclides in a gas-heated home. 2. The build-up of contamination on appliances in the kitchen environment. 3. The concentration in foods as a function of radionuclide, food type and preparation. 4. The maximum exposure plausible under specified conditions. (author)

  16. 2016 New Horizons Lecture: Beyond Imaging-Radiology of Tomorrow.

    Science.gov (United States)

    Hricak, Hedvig

    2018-03-01

    This article is based on the New Horizons lecture delivered at the 2016 Radiological Society of North America Annual Meeting. It addresses looming changes for radiology, many of which stem from the disruptive effects of the Fourth Industrial Revolution. This is an emerging era of unprecedented rapid innovation marked by the integration of diverse disciplines and technologies, including data science, machine learning, and artificial intelligence-technologies that narrow the gap between man and machine. Technologic advances and the convergence of life sciences, physical sciences, and bioengineering are creating extraordinary opportunities in diagnostic radiology, image-guided therapy, targeted radionuclide therapy, and radiology informatics, including radiologic image analysis. This article uses the example of oncology to make the case that, if members in the field of radiology continue to be innovative and continuously reinvent themselves, radiology can play an ever-increasing role in both precision medicine and value-driven health care. © RSNA, 2018.

  17. A survey of medical diagnostic imaging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today`s more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities.

  18. A survey of medical diagnostic imaging technologies

    International Nuclear Information System (INIS)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today's more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities

  19. Report on the 1. research coordination meeting on 'Development of therapeutic radiopharmaceuticals based on {sup 177}Lu for radionuclide therapy'

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Radionuclide therapy (RNT) employing radiopharmaceuticals labelled with emitting radionuclides is fast emerging as an important part of nuclear medicine. Radionuclide therapy is effectively utilized for bone pain palliation, thus providing significant improvement in quality of life of patients suffering from pain resulting from bone metastasis. Targeting primary diseases by using specific carrier molecules labelled with radionuclides is also widely investigated and efficacious products have been emerging for the treatment of Lymphoma and Neuroendocrine tumours. In order to ensure the wider use of radiopharmaceuticals, it is essential to carefully consider the choice of radionuclides that together with the carrier molecules will give suitable pharmacokinetic properties and therapeutic efficacy. The criteria for the selection of a radionuclide for radiotherapy are suitable decay characteristics and amenable chemistry. However, the practical considerations in selecting a radionuclide for targeted therapy are availability in high radionuclidic purity as well as high specific activity and low production cost and comfortable delivery logistics. {sup 177}Lu is one of the isotopes emerging as a clear choice for therapy. Worldwide, the isotope is under investigation for approximately 30 different clinical applications, including treatment of colon cancer, metastatic bone cancer, non-Hodgkin's lymphoma, and lung cancer. {sup 177}Lu decays with a half-life of 6.71 d by emission of particles with E{sub max} of 497 keV (78.6%), 384 keV (9.1%) and 176 keV (12.2%). It also emits photons of 113 keV (6.4%) and 208 keV (11%), that are ideally suited for imaging the in-vivo localization and dosimetric calculations applying a gamma camera. The physical half-life of {sup 177}Lu is comparable to that of {sup 131}I, the most widely used therapeutic radionuclide. The long halflife of {sup 177}Lu provides logistic advantage for production, QA/QC of the products as well as feasibility to

  20. Effect of Body Temperature on the Radionuclide Evaluation of Cerebral Blood Flow

    International Nuclear Information System (INIS)

    Mustafa, S. . E- mail: seham@hsc.edu.kw; Elgazzar, A.H.; Gopinath, S.; Mathew, M.; Khalil, M.

    2006-01-01

    Changes in regional cerebral blood flow (rCBF) may reflect physiological correlates of the disease state. In neuro-imaging studies, some diseases have frequently been reported to be associated with reduced or increased rCBF. In a previous study we had shown evidence of heat induced vasoconstriction of the carotid artery, which is the main vessel supplying blood to the brain. This vasoconstriction may lead to a decrease in cerebral blood flow in hyperthermic patients. Most radionuclide studies used to assess cerebral blood flow are routinely performed without taking into consideration patients' body temperature. In this regard it may be noted that results of radionuclide cerebral perfusion studies may be affected by hyperthermia, which could lead to false positive studies or misinterpretation of results when they are performed on patients suffering from various cerebrovascular diseases. The objective of the present study was to investigate the importance of body temperature and its effect on the results of radionuclide cerebral perfusion studies. Cerebral blood flow was assessed using Tc-99m hexamethylpropyleneamineoxime (Tc-99m HMPAO) imaging. Baseline scintigraphic images of the brain were obtained in 10 rabbits using a gamma camera equipped with a low energy parallel hole and high resolution collimator interfaced with a computer. Repeat brain studies were performed on the same rabbits at 3 and 6 days after raising the body temperature by 2 deg. C and 4 deg. C respectively using the same imaging protocol. The counts per pixel were determined on control and hyperthermia images. The uptake of Tc-99m HMPAO in the brain was found to be significantly reduced following hyperthermia implying reduction in blood flow. This decrease in cerebral perfusion appears to be variable from region to region, being more in the cerebral hemispheres, frontal areas (olfactory lobes) than in the cerebellum. Based on the results, the authors conclude that a rise in body temperature might

  1. Radionuclide diagnosis of emergency states

    International Nuclear Information System (INIS)

    Ishmukhametov, A.I.

    1985-01-01

    Solution of emergency state radionuclide diagnostics from the technical point of view is provided by the application of the mobile quick-operating equipment in combination with computers, by the use of radionuclides with acceptable for emergency medicine characteristics and by development of radionuclide investigation data propcessing express-method. Medical developments include the study of acute disease and injury radioisotope semiotics, different indication diagnostic value determining, comparison of the results, obtained during radionuclide investigation, with clinicolaboratory and instrumental data, separation of methodical complex series

  2. The key network communication technology in large radiation image cooperative process system

    International Nuclear Information System (INIS)

    Li Zheng; Kang Kejun; Gao Wenhuan; Wang Jingjin

    1998-01-01

    Large container inspection system (LCIS) based on radiation imaging technology is a powerful tool for the customs to check the contents inside a large container without opening it. An image distributed network system is composed of operation manager station, image acquisition station, environment control station, inspection processing station, check-in station, check-out station, database station by using advanced network technology. Mass data, such as container image data, container general information, manifest scanning data, commands and status, must be on-line transferred between different stations. Advanced network communication technology is presented

  3. In vivo measurements of bone-seeking radionuclides. Progress report, September 1, 1977--February 28, 1979

    International Nuclear Information System (INIS)

    Cohen, N.

    1978-01-01

    Progress is reported on the following research projects: estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull; contribution from radionuclides in the thoracic skeleton to in vivo measurements of activity in the lung; design and optimization characterictics of in vivo detection system; development of a calibration phantom structure for determining activity deposited in the thoracic skeleton; computer assisted in vivo measurements of internally deposited radionuclides using dual-crystal scintillation detectors; low energy, photon-emitting nuclides; reference spectra library; and in vivo measurements of exposed individuals

  4. In vivo measurements of bone-seeking radionuclides. Progress report, September 1, 1977--February 28, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N.

    1978-11-01

    Progress is reported on the following research projects: estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull; contribution from radionuclides in the thoracic skeleton to in vivo measurements of activity in the lung; design and optimization characterictics of in vivo detection system; development of a calibration phantom structure for determining activity deposited in the thoracic skeleton; computer assisted in vivo measurements of internally deposited radionuclides using dual-crystal scintillation detectors; low energy, photon-emitting nuclides; reference spectra library; and in vivo measurements of exposed individuals. (HLW)

  5. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Park, Hyun Soo

    2003-04-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. This project is composed of 6 subjects such as data production required for safety assessments, sorption properties and mechanisms, nuclide migration in the fractured rock, colloid formation and migration, nuclide speciation in deep geological environments, and total evaluation of geochemical behaviors considering multi-factors. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  6. Radionuclides incorporation in activated natural nanotubes

    International Nuclear Information System (INIS)

    Silva, Jose Parra

    2016-01-01

    Natural palygorskite nanotubes show suitable physical and chemical properties and characteristics to be use as potential nanosorbent and immobilization matrix for the concentration and solidification of radionuclides present in nuclear wastes. In the development process of materials with sorption properties for the incorporation and subsequent immobilization of radionuclides, the most important steps are related with the generation of active sites simultaneously to the increase of the specific surface area and suitable heat treatment to producing the structural folding. This study evaluated the determining parameters and conditions for the activation process of the natural palygorskite nanotubes aiming at the sorption of radionuclides in the nanotubes structure and subsequent evaluation of the parameters involve in the structural folding by heat treatments. The optimized results about the maximum sorption capacity of nickel in activated natural nanotubes show that these structures are apt and suitable for incorporation of radionuclides similar to nickel. By this study is verified that the optimization of the acid activation process is fundamental to improve the sorption capacities for specifics radionuclides by activated natural nanotubes. Acid activation condition optimized maintaining structural integrity was able to remove around 33.3 wt.% of magnesium cations, equivalent to 6.30·10 -4 g·mol -1 , increasing in 42.8% the specific surface area and incorporating the same molar concentration of nickel present in the liquid radioactive waste at 80 min. (author)

  7. Cerenkov luminescence imaging of medical isotopes.

    Science.gov (United States)

    Ruggiero, Alessandro; Holland, Jason P; Lewis, Jason S; Grimm, Jan

    2010-07-01

    The development of novel multimodality imaging agents and techniques represents the current frontier of research in the field of medical imaging science. However, the combination of nuclear tomography with optical techniques has yet to be established. Here, we report the use of the inherent optical emissions from the decay of radiopharmaceuticals for Cerenkov luminescence imaging (CLI) of tumors in vivo and correlate the results with those obtained from concordant immuno-PET studies. In vitro phantom studies were used to validate the visible light emission observed from a range of radionuclides including the positron emitters (18)F, (64)Cu, (89)Zr, and (124)I; beta-emitter (131)I; and alpha-particle emitter (225)Ac for potential use in CLI. The novel radiolabeled monoclonal antibody (89)Zr-desferrioxamine B [DFO]-J591 for immuno-PET of prostate-specific membrane antigen (PSMA) expression was used to coregister and correlate the CLI signal observed with the immuno-PET images and biodistribution studies. Phantom studies confirmed that Cerenkov radiation can be observed from a range of positron-, beta-, and alpha-emitting radionuclides using standard optical imaging devices. The change in light emission intensity versus time was concordant with radionuclide decay and was also found to correlate linearly with both the activity concentration and the measured PET signal (percentage injected dose per gram). In vivo studies conducted in male severe combined immune deficient mice bearing PSMA-positive, subcutaneous LNCaP tumors demonstrated that tumor-specific uptake of (89)Zr-DFO-J591 could be visualized by both immuno-PET and CLI. Optical and immuno-PET signal intensities were found to increase over time from 24 to 96 h, and biodistribution studies were found to correlate well with both imaging modalities. These studies represent the first, to our knowledge, quantitative assessment of CLI for measuring radiotracer uptake in vivo. Many radionuclides common to both nuclear

  8. Radionuclide daughter inventory generator code: DIG

    International Nuclear Information System (INIS)

    Fields, D.E.; Sharp, R.D.

    1985-09-01

    The Daughter Inventory Generator (DIG) code accepts a tabulation of radionuclide initially present in a waste stream, specified as amounts present either by mass or by activity, and produces a tabulation of radionuclides present after a user-specified elapsed time. This resultant radionuclide inventory characterizes wastes that have undergone daughter ingrowth during subsequent processes, such as leaching and transport, and includes daughter radionuclides that should be considered in these subsequent processes or for inclusion in a pollutant source term. Output of the DIG code also summarizes radionuclide decay constants. The DIG code was developed specifically to assist the user of the PRESTO-II methodology and code in preparing data sets and accounting for possible daughter ingrowth in wastes buried in shallow-land disposal areas. The DIG code is also useful in preparing data sets for the PRESTO-EPA code. Daughter ingrowth in buried radionuclides and in radionuclides that have been leached from the wastes and are undergoing hydrologic transport are considered, and the quantities of daughter radionuclide are calculated. Radionuclide decay constants generated by DIG and included in the DIG output are required in the PRESTO-II code input data set. The DIG accesses some subroutines written for use with the CRRIS system and accesses files containing radionuclide data compiled by D.C. Kocher. 11 refs

  9. "Seeing is believing": perspectives of applying imaging technology in discovery toxicology.

    Science.gov (United States)

    Xu, Jinghai James; Dunn, Margaret Condon; Smith, Arthur Russell

    2009-11-01

    Efficiency and accuracy in addressing drug safety issues proactively are critical in minimizing late-stage drug attritions. Discovery toxicology has become a specialty subdivision of toxicology seeking to effectively provide early predictions and safety assessment in the drug discovery process. Among the many technologies utilized to select safer compounds for further development, in vitro imaging technology is one of the best characterized and validated to provide translatable biomarkers towards clinically-relevant outcomes of drug safety. By carefully applying imaging technologies in genetic, hepatic, and cardiac toxicology, and integrating them with the rest of the drug discovery processes, it was possible to demonstrate significant impact of imaging technology on drug research and development and substantial returns on investment.

  10. Waste/Rock Interactions Technology Program: the status of radionuclide sorption-desorption studies performed by the WRIT program

    International Nuclear Information System (INIS)

    Serne, R.J.; Relyea, J.F.

    1982-04-01

    The most credible means for radionuclides disposed as solid wastes in deep-geologic repositories to reach the biosphere is through dissolution of the solid waste and subsequent radionuclide transport by circulating ground water. Thus safety assessment activities must consider the physicochemical interactions between radionculides present in ground water with package components, rocks and sediments since these processes can significantly delay or constrain the mass transport of radionuclides in comparison to ground-water movement. This paper focuses on interactions between dissolved radiouclides in ground water and rocks and sediments away from the near-field repository. The primary mechanism discussed is adsorption-desorption, which has been studied using two approaches. Empirical studies of adsorption-desorption rely on distribution coefficient measurements while mechanism studies strive to identify, differentiate and quantify the processes that control nuclide retardation

  11. Studies on distribution coefficient (Kd) of naturally occurring radionuclides in geological matrices

    International Nuclear Information System (INIS)

    Pandit, G.G.

    2014-01-01

    Accurate prediction of fate and transport of toxic and radioactive metals in the subsurface of uranium tailing pond sites is critical to the assessment of environmental impact and to the development of effective remediation technologies. The mobility of radionuclides and toxic metals is enhanced by acidification of tailings due to sulphide oxidation catalysed by microbial activity. Due to infiltration of water, there is a possibility of leaching of these radionuclides and toxic metals from the tailings pond to the ground water. Sorption onto mineral surfaces is an important mechanism for reducing radionuclide concentrations along ground water flow paths and retarding radionuclide migration to the accessible environment. Reactive transport of ground water contaminants often assume that the reaction governing the retardation of a particular contaminant or radionuclide can be described by simple partitioning constant, K d . This constant is assumed to account for all the reversible sorption processes affecting transport of the contaminant. Experimental determination of site-specific K d values is absolutely essential for the accurate estimation of reactive transport of these contaminants. The results of such studies would be helpful to model migration of these pollutants and to estimate the radiation dose to members of the public through groundwater drinking pathway at different distances from the tailings pond. In the present study it is clearly observed that K d values of most of the radionuclides are strongly dependent on different soil and ground water parameters. The relationships generated between distribution coefficient values of different radionuclides and different soil and ground water parameters can be used to generate look up table. And these relationships can also be used for the prediction of K d values of different radionuclides by using the different physico-chemical parameters of soil and ground water of the particular location

  12. Exposure to radionuclides in smoke from vegetation fires

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fernando P., E-mail: carvalho@itn.pt; Oliveira, João M.; Malta, Margarida

    2014-02-01

    Naturally occurring radionuclides of uranium, thorium, radium, lead and polonium were determined in bushes and trees and in the smoke from summer forest fires. Activity concentrations of radionuclides in smoke particles were much enriched when compared to original vegetation. Polonium-210 ({sup 210}Po) in smoke was measured in concentrations much higher than all other radionuclides, reaching 7255 ± 285 Bq kg{sup −1}, mostly associated with the smaller size smoke particles (< 1.0 μm). Depending on smoke particle concentration, {sup 210}Po in surface air near forest fires displayed volume concentrations up to 70 mBq m{sup −3}, while in smoke-free air {sup 210}Po concentration was about 30 μBq m{sup −3}. The estimated absorbed radiation dose to an adult member of the public or a firefighter exposed for 24 h to inhalation of smoke near forest fires could exceed 5 μSv per day, i.e, more than 2000 times above the radiation dose from background radioactivity in surface air, and also higher than the radiation dose from {sup 210}Po inhalation in a chronic cigarette smoker. It is concluded that prolonged exposure to smoke allows for enhanced inhalation of radionuclides associated with smoke particles. Due to high radiotoxicity of alpha emitting radionuclides, and in particular of {sup 210}Po, the protection of respiratory tract of fire fighters is strongly recommended. - Highlights: • Natural radionuclides in vegetation are in low concentrations. • Forest fires release natural radionuclides from vegetation and concentrate them in inhalable ash particles. • Prolonged inhalation of smoke from forest fires gives rise enhanced radiation exposure of lungs especially due to polonium. • Respiratory protection of fire fighters and members of public is highly recommended for radioprotection reasons.

  13. Determination of long-lived radionuclides at ultratrace level using advanced mass spectrometric techniques

    International Nuclear Information System (INIS)

    Zoriy, M.

    2005-11-01

    Determination of long-lived radionuclides at sub-fg concentration level is a challenging task in analytical chemistry. Inductively coupled plasma mass spectrometry (ICP-MS) with its ability to provide the sensitive and fast multielemental analysis is one of the most suitable method for the measurements of long lived radionuclides in the trace and ultra trace concentration range. In present the Ph.D. study a variety of procedures have been developed permitting the sub fg ml-1 determination of long-lived radionuclides (e.g. U, Th, Pu) as well as 226 Ra (T 1/2 = 1600 y) and 90 Sr (T 1/2 = 28.1 y) in different samples. In order to avoid isobaric interferences, to increase the sensitivity, precision and accuracy of the methods the application of different techniques: pre-concentration of the sample, off-line separation on the crown resin, measurements under cold plasma conditions, using microconcentric nebulizers (e.g DIHEN, DS-5) or the application of LA-ICP-MS for sample introduction have been studied. The limits of detection for different radionuclides was significantly improved in comparison to the ones reported in the literature, and, depending on the method applied, was varied from 10 -15 to 10 -18 g ml -1 concentration range. In addition to the analysis of long lived radionuclides, some other elements, that can present potential interest to the analyzed sample, were measured within the framework of the present study. Laser ablation inductively coupled plasma mass spectrometry (LAICP- MS) was used to produce images of element distribution in 20μm m thin sections of human brain tissue. The sample surface was scanned (raster area ∝80 mm 2 ) with a focused laser beam (wavelength 213 nm, diameter of laser crater 50μm, and laser power density 3x10 9 W cm -2 ) in a cooled laser ablation chamber developed for these measurements. Cross sections of human brain samples - hippocampus as well as brain tissues infected and non-infected with Glioblastoma Multiforme (tumor

  14. Radionuclide angiocardiography in the diagnosis of congenital heart disorders

    International Nuclear Information System (INIS)

    Jones, R.H.; Austin, E.H.; Peter, C.A.; Sabiston, D.C. Jr.

    1981-01-01

    Radionuclide angiocardiography provides a noninvasive assessment of cardiac function and blood flow through the heart and lungs. During the past three years, this procedure has been used at the Duke University Medical Center for evaluation of 343 patients with congenital heart disorders. A review of this experience shows tat the resulting data were frequently useful in the surgical management of these patients. In patients with abnormal blood flow patterns, noninvasive imaging of blood flow was useful before and after operative correction. Radionuclide measurements of left-to-right intracardiac shunts were sufficiently accurate for use in the initial evaluation of patients with murmurs and to document the absence of shunt after operative closure of intracardiac septal defects. Moreover, measurements of right-to-left cardiac shunts were of benefit in the management of children with cyanotic heart disease. Measurements of left ventricular function obtained during rest and exercise were most useful in patients with origin of the left coronary artery from the pulmonary artery and in patients with congenital valvular insufficiency. This experience demonstrates that radionuclide angiocardiography provides important measurements of central hemodynamics and cardiac function which are useful in the management of patients with congenital heart disorders

  15. The use of web internet technologies to distribute medical images

    International Nuclear Information System (INIS)

    Deller, A.L.; Cheal, D.; Field, J.

    1999-01-01

    Full text: In the past, internet browsers were considered ineffective for image distribution. Today we have the technology to use internet standards for picture archive and communication systems (PACS) and teleradiology effectively. Advanced wavelet compression and state-of-the-art JAVA software allows us to distribute images on normal computer hardware. The use of vendor and database neutral software and industry-standard hardware has many advantages. This standards base approach avoids the costly rapid obsolescence of proprietary PACS and is cheaper to purchase and maintain. Images can be distributed around a hospital site, as well as outside the campus, quickly and inexpensively. It also allows integration between the Hospital Information System (HIS) and the Radiology Information System (RIS). Being able to utilize standard internet technologies and computer hardware for PACS is a cost-effective alternative. A system based on this technology can be used for image distribution, archiving, teleradiology and RIS integration. This can be done without expensive specialized imaging workstations and telecommunication systems. Web distribution of images allows you to send images to multiple places concurrently. A study can be within your Medical Imaging Department, as well as in the ward and on the desktop of referring clinicians - with a report. As long as there is a computer with an internet access account, high-quality images can be at your disposal 24 h a day. The importance of medical images for patient management makes them a valuable component of the patient's medical record. Therefore, an efficient system for displaying and distributing images can improve patient management and make your workplace more effective

  16. Radionuclide salivary imaging usefulness in a private otolaryngology practice

    International Nuclear Information System (INIS)

    Schall, G.L.; Smith, R.R.; Barsocchini, L.M.

    1981-01-01

    Radionuclide salivary gland scans were performed on 44 patients using sodium pertechnetate Tc 99m. The accuracy of the scans and their usefulness in the clinical treatment of the patients were reviewed. The scan provided helpful information in 31 of 38 cases in which adequate follow-up data were available, although it proved diagnostic in only six patients. It was particularly useful in the evaluation of primary salivary gland neoplasms, acute and chronic sialadenitis, and sialolithiasis, as well as in the differential diagnosis of xerostomia. The value of this procedure in the elucidation of a variety of morphologic and functional diseases of these glands warrants its greater application in private otolaryngologic practices

  17. Adoption and diffusion of a new imaging technology: a magnetic resonance imaging prospective

    International Nuclear Information System (INIS)

    Hillman, B.J.; Winkler, J.D.; Phelps, C.E.; Aroesty, J.; Williams, A.P.

    1984-01-01

    Adoption of magnetic resonance imaging (MRI) by individual purchasers and by the health care system will be influenced by many factors. A framework for considering these influences is offered, incorporating them into four major considerations: (1) MRI and its attributes - the technology, its safety and efficacy, and the benefits of acquisition; (2) communication channels - commercial and professional; (3) time for consideration of adoption and experiential testing; and (4) the medical system, including potential acquirers, health planning, and reimbursement. Factors that should most strongly motivate early adoption are the potential of the technology for providing new and useful clinical information and the competitive and economic benefits that early acquirers might enjoy. Important discouragements include the possibility of early obsolescence and that MRI represents an economic risk under diagnostic-related-group reimbursement. The less risky approach for most practices is to delay acquisition of MRI pending further experience with the technology and the changing reimbursement climate

  18. A survey of medical diagnostic imaging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today's more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities.

  19. Radioactivity and the environment: technical approaches to understand the role of arbuscular mycorrhizal plants in radionuclide bioaccumulation

    Science.gov (United States)

    Davies, Helena S.; Cox, Filipa; Robinson, Clare H.; Pittman, Jon K.

    2015-01-01

    Phytoaccumulation of radionuclides is of significant interest with regards to monitoring radionuclide build-up in food chains, developing methods for environmental bioremediation and for ecological management. There are many gaps in our understanding of the characteristics and mechanisms of plant radionuclide accumulation, including the importance of symbiotically-associated arbuscular mycorrhizal (AM) fungi. We first briefly review the evidence that demonstrates the ability of AM fungi to enhance the translocation of 238U into plant root tissues, and how fungal association may prevent further mobilization into shoot tissues. We then focus on approaches that should further advance our knowledge of AM fungi–plant radionuclide accumulation. Current research has mostly used artificial cultivation methods and we consider how more ecologically-relevant analysis might be performed. The use of synchrotron-based X-ray fluorescence imaging and absorption spectroscopy techniques to understand the mechanisms of radionuclide transfer from soil to plant via AM fungi is evaluated. Without such further knowledge, the behavior and mobilization of radionuclides cannot be accurately modeled and the potential risks cannot be accurately predicted. PMID:26284096

  20. Strategy for a consistent selection of radionuclide migration parameters for the Belgian safety and feasibility case-1

    International Nuclear Information System (INIS)

    Bruggeman, C.; Maes, N.; Salah, S.; Brassinnes, S.; Van Geet, M.

    2010-01-01

    Document available in extended abstract form only. The purpose of this presentation is to describe the strategy for the selection of retention and migration parameters for safety-relevant nuclides that was developed in the framework of the Belgian Safety and Feasibility Case SFC-1. A geochemical database containing state-of-the-art retention and migration parameters of all safety-relevant radionuclides, is ideally based on a thermodynamic understanding and an ability to accurately describe the geochemical and transport behaviour of all these radionuclides under the geochemical conditions that are considered for a reference host formation. In Belgium, this reference formation is Boom Clay. The parameters will be used in Performance Assessment (PA) calculations, and therefore must also be adapted to PA models. Since these models currently use only a four parameters for every radionuclide, the whole geochemical and transport behaviour must be comprised to a very limited parameter set that describe on the one hand chemical retention within the Boom Clay formation, and on the other hand transport through the Boom Clay formation. Chemical retention considers two concepts: 1) a concentration limit (S), which represents the mobile concentration of a nuclide present in the aqueous phase under undisturbed far field Boom Clay conditions; 2) a retardation (R/Kd) factor, which represents the uptake of a mobile nuclide by the inorganic and organic phases present in the Boom Clay formation. For mobility/migration two additional concepts are introduced: 3) the diffusion accessible porosity (η), which is the total physical space available for transport of a nuclide. The maximum value of η is limited by the water content of the formation; 4) the pore diffusion coefficient (Dp), which represents the transport velocity of a nuclide in a diffusion-dominated system. Within the framework of SFC-1, primary focus is laid on the compilation of parameter ranges, instead of individual &apos