WorldWideScience

Sample records for radionuclide bone scan

  1. Radiographic skeletal survey and radionuclide bone scan in Langerhans cell histiocytosis of bone

    Energy Technology Data Exchange (ETDEWEB)

    Nieuwenhuyse, J.P. van [Department of Radiology and Medical Imaging, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Clapuyt, P. [Department of Radiology and Medical Imaging, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Malghem, J. [Department of Radiology and Medical Imaging, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Everarts, P. [Department of Radiology and Medical Imaging, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Melin, J. [Department of Nuclear Medicine, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Pauwels, S. [Department of Nuclear Medicine, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Brichard, B. [Department of Pediatric Hematology, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Ninane, J. [Department of Pediatric Hematology, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Vermylen, C. [Department of Pediatric Hematology, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium); Cornu, G. [Department of Pediatric Hematology, Cliniques Universitaires St-Luc, University of Louvain Medical School, Brussels (Belgium)

    1996-10-01

    Background. The lack of a consensus in the literature on the imaging strategy in Langerhans cell histiocytosis (LCH) bone lesions in childhood. Objective. To evaluate the relative value of radionuclide bone scan (RBS) and radiographic skeletal survey (RSS) in the detection of LCH bone lesions, both in the initial work-up of the disease and during the follow-up period. Materials and methods. Ten children with bone lesions evaluated by means of RSS and RBS in a retrospective study (1984-1993). Results. Fifty radiologically and/or scintigraphically abnormal foci were detected: 27 anomalies in the initial work-up (12 by both RSS and RBS, 8 by RSS only and 7 by RBS only) and 23 additional anomalies during follow-up (10 by both RSS and RBS, 10 by RSS only and 3 by RBS only). RSS+/RBS- lesions (n = 18) are more frequently encountered in the skull (P = 0.038), and more frequently lack radiologic signs of osteoblastic activity (P = 0.020), than RSS+/RBS+ lesions (n = 22). RSS-/RBS+ abnormalities (n = 10) were most frequently insignificant. Conclusion. In the initial work-up both RSS and RBS should be carried out, while in the follow-up only RSS should be performed. (orig.). With 2 figs., 4 tabs.

  2. Changes observed in radionuclide bone scans during and after teriparatide treatment for osteoporosis

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Amelia E.B.; Blake, Glen M.; Fogelman, Ignac [King' s College London, School of Medicine, Department of Nuclear Medicine, London (United Kingdom); Taylor, Kathleen A.; Ruff, Valerie A.; Rana, Asad E.; Wan, Xiaohai [Eli Lilly and Company, Indianapolis, IN (United States)

    2012-02-15

    Visual changes on radionuclide bone scans have been reported with teriparatide treatment. To assess this, serial studies were evaluated and quantified in ten postmenopausal women with osteoporosis treated with teriparatide (20 {mu}g/day subcutaneous) who had {sup 99m}Tc-methylene diphosphonate (MDP) bone scans (baseline, 3 and 18 months, then after 6 months off therapy). Women were injected with 600 MBq {sup 99m}Tc-MDP, and diagnostic bone scan images were assessed at 3.5 h. Additional whole-body scans (10 min, 1, 2, 3 and 4 h) were analysed for {sup 99m}Tc-MDP skeletal plasma clearance (K{sub bone}). Regional K{sub bone} differences were obtained for the whole skeleton and six regions (calvarium, mandible, spine, pelvis, upper and lower extremities). Bone turnover markers (BTM) were also measured. Most subjects showed visual changes on 3- and 18-month bone scan images that disappeared after 6 months off therapy. Enhanced uptake was seen predominantly in the calvarium and lower extremities. Whole skeleton K{sub bone} displayed a median increase of 22% (3 months, p = 0.004) and 34% (18 months, p = 0.002) decreasing to 0.7% (6 months off therapy). Calvarium K{sub bone} changes were three times larger than other sites. After 6 months off therapy, all K{sub bone} and BTM values returned towards baseline. The increased {sup 99m}Tc-MDP skeletal uptake with teriparatide indicated increased bone formation which was supported by BTM increases. After 6 months off therapy, metabolic activity diminished towards baseline. The modulation of {sup 99m}Tc-MDP skeletal uptake during treatment was the result of teriparatide's metabolic activity. These findings may aid the radiological evaluation of similar teriparatide patients having radionuclide bone scans. (orig.)

  3. Multiple bone metastases seen on radionuclide bone scans and distributed to batson's plexus

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Yong; Lee, Suck Hong; Kim, Byung Soo; Chung, Hyun Woo [Pusan Univ. College of Medicine, Pusan (Korea, Republic of); Huh, Jin Do [Kosin Mecial College, Pusan (Korea, Republic of); Lee, Young Il; Park, Byung Ho [Donga Univ. College of Medicine, Pusan (Korea, Republic of); Lee, Young Joon; Eun, Choong Ki [Inje University. College of Medicine, Pusan (Korea, Republic of)

    1998-08-01

    Multiple bone metastases that appear on 99mTc-MDP bone scans tend to be distributed in the axial skeleton, including the proximal humeri and femora;this is similar to the distribution seen in Batson's paravertebral plexus. The purpose of this study was, therefore, to evaluate- by examining the anatomic distribution of metastases- the metastatic mechanism of cancer cells of various primary tumors in Batson's plexus.Materials and Methods: Three hundred and forth-five known cases of primary tumors and multiple bone metastases were confirmed by bone scan imaging. The axial skeleton was divided into seven parts: skull, ribs, scapulas,spine, pelvis, proximal humeri, and proximal femora. In addition, the spine was divided into cervical, thoracic and lumbar areas. Results: Among the 345 cases, bony metastases were distributed as follows: ribs, 186 (53.9%);spinal areas, 172 (49.9%); pelvis, 94 (27.2%); proximal femora, 85 (24.6%); skull, 63 (18.3%); proximal humeri, 45(13%); and scapulas, 31 (9%). Among the 243 primarily thoracic cancer cases (e.g. lung, breast or esophagus),distribution was as follows: ribs, 142 (58.4%); spinal areas 111 (45.7%); and pelvis, 54 (22.2%). Among the 69 cancers which were primarily of the upper abdomen (e.g. stomach or liver), distribution spinal areas, 44 (63.8%);ribs, 33 (47.8%); and pelvis, 26 (37.7%). While the 33 primarily pelvic cancers (e.g. prostate, uterine cervix or bladder), were distributed between spinal areas (17, 51.5%), the pelvis (13, 39.4%), and the ribs (11, 33.3%).There were no statistically significant differences in the distribution of bony metastases according to primary cancers. Conclusion: Multiple bone metastases, as seen on bone scan images, coincided with the distribution of Batson's plexus. We therefore conclude that although pelvic tumors can metastasize to the axial skeleton by directly anatomising into Batson's plexus, other primary tumors metastasize from systemic veins to Batson

  4. Radionuclide bone scanning in neuroblastoma: skeletal metastases and primary tumor localization of /sup 99m/Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Podrasky, A.E.; Stark, D.D.; Hattner, R.S.; Gooding, C.A.; Moss, A.A.

    1983-09-01

    Of 42 radionuclide bone scans in 35 children with neuroblastoma, 21 were abnormal for the presence of skeletal metastases. Of the 21 abnormal scans, 16 were corroborated by positive bone-marrow biopsy or clinical data. The false-negative and false-positive rates for bone scanning were 4.8% and 9.5%, respectively. Calcification of the primary tumor was seen on pretreatment computed tomographic (CT) scans in 24 (89%) of 27 cases, while only 13 (48%) of 27 were detectable by plain radiographs. Uptake of /sup 99m/Tc methylene diphosphate /sup 99m/Tc-MDP) by the primary tumor occurred in 20 of 27 cases, but correlation between tumor uptake and calcification was not statistically significant. All children with markedly elevated urinary vanillylmandelic acid exhibited primary tumor uptake. Survival was not affected independently by primary tumor uptake.

  5. The natural course of radionuclide bone scanning in the evaluation of total knee replacement--a 2 year prospective study.

    Science.gov (United States)

    Duus, B R; Boeckstyns, M; Stadeager, C

    1990-05-01

    In order to establish the natural course of radionuclide bone scanning images after total knee replacement 41 consecutive patients were scheduled for examination 3, 7, 12 and 24 months after surgery. The mean age was 69 years (range 50-80 years); the female:male ratio was 4:1. Thirty-two patients completed the entire program. A total of 143 99Tcm medronic acid complex scintigrams was performed. No significant difference between the grades of total scintigraphic uptake at any of the four examinations nor any difference between the first and the last examinations could be demonstrated (P = 0.58, Friedman test and P = 0.20, Wilcoxon test, respectively). Twelve months after surgery one fifth of the knees still demonstrated definitely increased scintigraphic uptake and 24 months after surgery 12.5% of the knees had definitely increased uptake. We believe that the increased uptake seen for a variable length of time after surgery limits the usefulness of radionuclide bone scanning in the evaluation of total knee replacement.

  6. Bone scanning in otolaryngology.

    Science.gov (United States)

    Noyek, A M

    1979-09-01

    Modern radionuclide bone scanning has introduced a new concept in physiologic and anatomic diagnostic imaging to general medicine. As otolaryngologists must diagnose and treat disease in relation to the bony and/or cartilaginous supporting structures of the neurocranium and upper airway, this modality should be included in the otolaryngologist's diagnostic armamentarium. It is the purpose of this manuscript to study the specific applications of bone scanning to our specialty at this time, based on clinical experience over the past three years. This thesis describes the development of bone scanning in general (history of nuclear medicine and nuclear physics; history of bone scanning in particular). General concepts in nuclear medicine are then presented; these include a discussion of nuclear semantics, principles of radioactive emmissions, the properties 99mTc as a radionuclide, and the tracer principle. On the basis of these general concepts, specific concepts in bone scanning are then brought forth. The physiology of bone and the action of the bone scan agents is presented. Further discussion considers the availability and production of the bone scan agent, patient factors, the gamma camera, the triphasic bone scan and the ultimate diagnostic principle of the bone scan. Clinical applications of bone scanning in otolaryngology are then presented in three sections. Proven areas of application include the evaluation of malignant tumors of the head and neck, the diagnosis of temporomandibular joint disorders, the diagnosis of facial fractures, the evaluation of osteomyelitis, nuclear medicine imaging of the larynx, and the assessment of systemic disease. Areas of adjunctive or supplementary value are also noted, such as diagnostic imaging of meningioma. Finally, areas of marginal value in the application of bone scanning are described.

  7. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Nnamdi Norbert Jibiri

    2016-10-01

    Full Text Available Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP without cannula and with cannula were 10.68 (720.2 and 13.82 (556.4 mSv per week (and per annum, respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99m

  8. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Bone Densitometry (DEXA) Bone densitometry, also called dual-energy ... limitations of DEXA Bone Densitometry? What is a Bone Density Scan (DEXA)? Bone density scanning, also called ...

  9. Bone scan

    Science.gov (United States)

    ... legs, or spine fractures) Diagnose a bone infection (osteomyelitis) Diagnose or determine the cause of bone pain, ... 2015:chap 43. Read More Broken bone Metabolism Osteomyelitis Review Date 12/10/2015 Updated by: Jatin ...

  10. When to perform positron emission tomography/computed tomography or radionuclide bone scan in patients with recently diagnosed prostate cancer

    Directory of Open Access Journals (Sweden)

    Caldarella C

    2013-06-01

    Full Text Available Carmelo Caldarella,1 Giorgio Treglia,2 Alessandro Giordano,1 Luca Giovanella2 1Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Rome, Italy; 2Department of Nuclear Medicine and PET/CT Centre, Oncology Institute of Southern Switzerland, Bellinzona, Switzerland Abstract: Skeletal metastases are very common in prostate cancer and represent the main metastatic site in about 80% of prostate cancer patients, with a significant impact in patients' prognosis. Early detection of bone metastases is critical in the management of patients with recently diagnosed high-risk prostate cancer: radical treatment is recommended in case of localized disease; systemic therapy should be preferred in patients with distant secondary disease. Bone scintigraphy using radiolabeled bisphosphonates is of great importance in the management of these patients; however, its main drawback is its low overall accuracy, due to the nonspecific uptake in sites of increased bone turnover. Positron-emitting radiopharmaceuticals, such as fluorine-18-fluorodeoxyglucose, choline-derived drugs (fluorine-18-fluorocholine and carbon-11-choline and sodium fluorine-18-fluoride, are increasingly used in clinical practice to detect metastatic spread, and particularly bone involvement, in patients with prostate cancer, to reinforce or substitute information provided by bone scan. Each radiopharmaceutical has a specific mechanism of uptake; therefore, diagnostic performances may differ from one radiopharmaceutical to another on the same lesions, as demonstrated in the literature, with variable sensitivity, specificity, and overall accuracy values in the same patients. Whether bone scintigraphy can be substituted by these new methods is a matter of debate. However, greater radiobiological burden, higher costs, and the necessity of an in-site cyclotron limit the use of these positron emission tomography methods as first-line investigations in patients with prostate cancer

  11. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... of DXA Bone Densitometry? What is a Bone Density Scan (DXA)? Bone density scanning, also called dual-energy x-ray absorptiometry ( ... is today's established standard for measuring bone mineral density (BMD). An x-ray (radiograph) is a noninvasive ...

  12. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, J.C. (Univ. of California, San Francisco); Hattner, R.S.; Murray, W.R.; Genant, H.K.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery and seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.

  13. 核素骨扫描与MRI对肺癌脊柱骨转移癌灶的检出情况比较%Comparison of radionuclide bone scan and MRI for vertebral metastasis detection from lung cancer tumor

    Institute of Scientific and Technical Information of China (English)

    李海文; 司素梅

    2013-01-01

    Objective To compare radionuclide bone scan and MRI for vertebral metastasis detection fromlung cancer tumor.Methods 45 cases with lung cancer were collected for radionuclide bone scan and MRI scan,the scanning time within 15 days.Three deputy directors read the piece,the detection rate of two kinds of examination methods was compared.Results 35 cases were detected by radionuclide bone scan and MRI (x2 =0.135,P >0.05).It was detected 84 positive bone metastases vertebral,detected in 45 of radionuclide bone scan,MRI detected73,the difference was significant (x2 =15.300,P < 0.05).Conclusion MRI can effectively detect lung cancer spine bone vertebral metastasis loci without false positive lesions,which contribute to the diagnosis and treatment of disease,worthy of clinical promotion.%目的 比较核素骨扫描与MRI对肺癌脊柱骨转移癌灶的检出情况.方法 对45例肺癌患者均行核素骨扫描与MRI扫描,两次扫描时间在15 d内,由3名副主任医师阅片,比较两种检查方法检出情况.结果 核素骨扫描与MRI共检出阳性病例35例,两种方法检出率差异无统计学意义(x2 =0.135,P>0.05);两种方法共检出84个阳性骨转移瘤椎体,其中核素骨扫描检出45个,MRI检出73个,两种方法差异有统计学意义(x2=15.300,P <0.05).结论 MRI可有效地检出肺癌脊柱骨椎体转移癌灶且不存在假阳性病灶,有助于疾病的诊断治疗,值得临床推广.

  14. Radionuclide imaging of bone marrow disorders

    NARCIS (Netherlands)

    Agool, Ali; Glaudemans, Andor W. J. M.; Boersma, Hendrikus H.; Dierckx, Rudi A. J. O.; Vellenga, Edo; Slart, Riemer H. J. A.

    2011-01-01

    Noninvasive imaging techniques have been used in the past for visualization the functional activity of the bone marrow compartment. Imaging with radiolabelled compounds may allow different bone marrow disorders to be distinguished. These imaging techniques, almost all of which use radionuclide-label

  15. Role of bone scanning in neonatal rickets

    Energy Technology Data Exchange (ETDEWEB)

    Saul, P.D.; Lloyd, D.J.; Smith, F.W.

    1983-03-01

    Preterm infants are at increased risk from rickets. Radionuclide bone scanning is a useful aid in suspected cases. It offers advantages over conventional radiology in terms of sensitivity, radiation dose and extent of examination. Unsuspected fractures of clinical or medicolegal significance may be detected. Two cases are described in which the technique confirmed the diagnosis and assisted management.

  16. Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study

    DEFF Research Database (Denmark)

    Duus, B R; Boeckstyns, M; Kjaer, L

    1987-01-01

    The authors examined the relationships among Tc-99m radionuclide bone scan findings, pain, and radiolucent lines in 35 postsurgical knees. Our prospective study included bone scans, as well as radiographic and clinical examination three, seven, and 12 months after knee replacement surgery in 35...... and nonpainful knees, and the degree of isotope uptake did not correlate with the development of radiolucent lines around the prosthetic components....

  17. Radionuclide imaging of bone marrow disorders

    Energy Technology Data Exchange (ETDEWEB)

    Agool, Ali [Department of Nuclear Medicine, Medical Center Twente, Hengelo (Netherlands); University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, P.O. Box 30,001, Groningen (Netherlands); Glaudemans, Andor W.J.M.; Boersma, Hendrikus H.; Slart, Riemer H.J.A. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, P.O. Box 30,001, Groningen (Netherlands); Dierckx, Rudi A.J.O. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, P.O. Box 30,001, Groningen (Netherlands); Ghent University, Ghent (Belgium); Vellenga, Edo [University Medical Center Groningen, University of Groningen, Department of Hematology, Groningen (Netherlands)

    2011-01-15

    Noninvasive imaging techniques have been used in the past for visualization the functional activity of the bone marrow compartment. Imaging with radiolabelled compounds may allow different bone marrow disorders to be distinguished. These imaging techniques, almost all of which use radionuclide-labelled tracers, such as {sup 99m}Tc-nanocolloid, {sup 99m}Tc-sulphur colloid, {sup 111}In-chloride, and radiolabelled white blood cells, have been used in nuclear medicine for several decades. With these techniques three separate compartments can be recognized including the reticuloendothelial system, the erythroid compartment and the myeloid compartment. Recent developments in research and the clinical use of PET tracers have made possible the analysis of additional properties such as cellular metabolism and proliferative activity, using {sup 18}F-FDG and {sup 18}F-FLT. These tracers may lead to better quantification and targeting of different cell systems in the bone marrow. In this review the imaging of different bone marrow targets with radionuclides including PET tracers in various bone marrow diseases are discussed. (orig.)

  18. Bone marrow scan evaluation of arthropathy in sickle cell disorders

    Energy Technology Data Exchange (ETDEWEB)

    Alavi, A.; Schumacher, H.R.; Dorwart, B.; Kuhl, D.E.

    1976-04-01

    Twelve patients with sickle cell hemoglobinopathies and arthropathy were studied, using technetium Tc 99m sulfur colloid bone marrow scans. Eight of 12 had decreased marrow radionuclide activity adjacent to painful joints, suggesting obliteration of vessels supplying bone marrow. Four patients without marrow defects on scanning had causes other than infarction for their joint symptoms, viz, small fractures, postinfectious synovitis, degenerative arthritis, and osteochondromas. Roentgenograms never showed bony abnormalities in five patients with marrow infarctions, and, in three others, showed defects several months later than did the marrow scans. Bone marrow scans offer a sensitive and early diagnostic aid in sickle cell hemoglobinopathies with arthropathy.

  19. Quantification of radionuclide uptake levels for primary bone tumors

    Directory of Open Access Journals (Sweden)

    Hasford Francis

    2015-04-01

    Full Text Available The purpose of the study is to quantify the level of uptake of administered radionuclide in primary bone tumors for patients undergoing bone scintigraphy. Retrospective study on 48 patient's scintigrams to quantify the uptake levels of administered radiopharmaceuticals was performed in a nuclear medicine unit in Ghana. Patients were administered with activity ranging between 0.555 and 1.110 MBq (15–30 mCi, and scanned on Siemens e.cam SPECT system. Analyses on scintigrams were performed with Image J software by drawing regions of interest (ROIs over identified hot spots (pathologic sites. Nine skeletal parts namely cranium, neck, shoulder, sacrum, sternum, vertebra, femur, ribcage, and knee were considered in the study, which involved 96 identified primary tumors. Radionuclide uptakes were quantified in terms of the estimated counts of activity per patient for identified tumor sites. Average normalized counts of activity (nGMC per patient ranged from 5.2759 ± 0.6590 cts/mm2/MBq in the case of cranium tumors to 72.7569 ± 17.8786 cts/mm2/MBq in the case of ribcage tumors. The differences in uptake levels could be attributed to different mechanisms of Tc-99m MDP uptake in different types of bones, which is directly related to blood flow and degree of osteoblastic activity. The overall normalized count of activity for the 96 identified tumors was estimated to be 23.0350 ± 19.5424 cts/mm2/MBq. The study revealed highest uptake of activity in ribcage and least uptake in cranium. Quantification of radionuclide uptakes in tumors is important and recommended in assessing patient's response to therapy, doses to critical organs and in diagnosing tumors.

  20. Interesting bone scans - unusual findings

    Energy Technology Data Exchange (ETDEWEB)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B. [Wollongong Hospital, Wollongong, NSW (Australia)

    1997-12-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  1. EVALUATION OF RADIONUCLIDE BONE IMAGING FOR SKELETAL DISEASE

    Institute of Scientific and Technical Information of China (English)

    林奋; 袁济民

    1993-01-01

    Whole body bone scan imaging of 99mTc-MDP was performed in 80 casesfrom Sept 1991 to Feb 1992. Among them 20 patients showed negtive bone imaging and56 patients showed positive bone imaging. There were false-positive bone imaging in 4 pa-tients. Bone scan imaging has been regarded as a useful method in the early diagnosis ofshelatal disease, especially in old patients with bone metastasis. But the final confirmationof malignancy should be still cautious.

  2. Treatment with bone-seeking radionuclides for painful bone metastases in patients with lung cancer

    DEFF Research Database (Denmark)

    Zacho, Helle D; Karthigaseu, Nita Nishanthiny; Fuglsang, Randi

    2017-01-01

    Treatment with bone-seeking radionuclides may provide palliation from pain originating from bone metastases. However, most studies have been conducted in patients with prostate cancer and patients with breast cancer. We aimed to perform a systematic review of the use of radionuclide treatment...

  3. 面部不对称畸形患者下颌骨核素骨扫描临床分析%Clinical analysis of radionuclide bone scan in patients with facial asymmetry

    Institute of Scientific and Technical Information of China (English)

    屈伟; 刘浏; 丁石梅; 王社教

    2013-01-01

    the body's growth and development trend.We can analyze the trend of mandible development by radionuclide bone scan and select proper time and type of treatment.

  4. Radionuclide imaging of bone marrow in hematologic systemic disease

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, F.; Hahn, K.; Gamm, H.

    1987-02-01

    Radionuclide imaging studies of the bone marrow were carried out in 164 patients suffering from hematologic systemic disease. One third of 90 patients with Hodgkin lymphoma (HL) or Non Hodgkin lymphoma (NHL) displayed a pathological distribution pattern representing bone marrow expansion. In HL there were 17% accumulation defects caused by metastases in contrast to only 7% in NHL. Among 30 patients with chronic myelocytic leukemia bone marrow expansion was found in 60%, bone marrow displacement and aplasia 10%. Focal bone marrow defects were found in 3 patients. All patients with primary polycythemia rubra vera displayed a pathologic bone marrow distribution pattern as well as splenomegaly. All patients with acute myelocytic leukemia (AML) and one patient with an acute lymphatic leukemia (ALL) had a pathological distribution pattern with bone marrow expansion and displacement. Focal bone marrow defects were not seen. Multiple myeloma with bone marrow expansion was found in 6 of 12 patients and focal accumulation defects were found in 40%, the latter lesions being not visible or equivocal on skeletal imaging studies. Pathological changes in liver and spleen were found in a high percentage of the total collective. The results document the important clinical value of bone marrow scintigraphy among the hematologic diseases studied.

  5. Gout: Value of bone scanning

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, J.P.; Cardenas, R.; Bell, L.; Gonzalez Griego, J.

    1986-12-01

    11 male patients with gout were studied by means of bone scintigraphy with /sup 99m/TcMDP. This diagnostic method rendered possible the diagnosis of clinically or roentgenologically occult bone involvement. Bone scintigraphy may be useful procedure to monitor therapy of gout.

  6. Radionuclide Bone Scan Combined with PSA, fPSA and fPSA/tPSA Ratio for Assessment of Prostatic Cancer Patients with Bone Metastasis%放射性核素骨显像联合PSA、fPSA、fPSA/tPSA评价前列腺癌骨转移

    Institute of Scientific and Technical Information of China (English)

    赵辉; 安建平; 徐晓红; 王晶

    2011-01-01

    Objective To assess the value of radionuclide bone scan combined with PSA, fPSA and fPSA/tPSA for diagnosis prostatic cancer with hone metastasis. Methods Serum levels of PSA, fPSA and fPSA/tPSA ratio were detemined in ① 35 prostatic cancer patients with definite bone metastasis lesions shown on radionucfide bone scan, ② 35 prostatic cancer patients without bone metastasis, ③ 30 patients with benign prostatic disorders and ④ 35 controls. Results The serum tumor markers levels in patients with osseous metastasis were significantly higher than those in the other three groups ( P <0.01 ). Among them,the levels in patients with more then 2 bone lesions were significantly higher than those in patients with only one or two bone lesions ( P < 0. 01 ). The serum tumor markers levels in patients without osseous metastasis were only significantly higher than those in patients with benign prostatic disorders and controls. The sensitivity of fPSA/tPSA ratio < 0.2 was highest ( 85.7%), but specificity lower ( 45.71%). The sensitivity combining tPSA/tPSA ratio and radionuclide bone scan ( ≤2 ) was lowest ( 62. 9%), but specificity was highest ( 77.14%). Conclusion PSA, fPSA and tfSA/tPSA ratio were related with osseous metastasis from prostatic cancer. Combining them was increase on diagnosis the osseous metastasis of prostatic cancer and is a valuable scheme for early detection of skeletal metastasis of prostatic cancer, especially when the results of bone scanning is equivocal. Detemination of the serum tumor markers levels would be helpful for dynamic monitoring of the extent of metastasis.%目的:评价前列腺癌患者放射性核素骨显像与血清前列腺特异抗原测定的诊断价值.方法:随机选择前列腺癌患者骨显像示骨转移与骨显像正常患者各35例,前列腺良性病患者30例及健康体检者35例,分别测定其血清中PSA、fPSA、fPSA/tPSA的含量.结果:前列腺癌无骨转移组PSA、fPSA水平较对照

  7. Bone scans after total knee arthroplasty in asymptomatic patients. Cemented versus cementless

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, A.A.; Wyatt, R.W.; Daniels, A.U.; Armstrong, L.; Alazraki, N.; Taylor, A. Jr. (Univ. of Utah Medical Center, Salt Lake City (USA))

    1990-02-01

    The natural history of bone scans after total knee arthroplasty (TKA) was studied in 26 patients with 28 cemented TKAs and 29 patients with 31 cementless TKAs. The bone scans were examined at specified postoperative intervals. Radionuclide activity of the femoral, tibial, and patellar regions was measured. Six patients who developed pain postoperatively were excluded. Bone scans immediately postoperative and at three months demonstrated increased uptake, which gradually decreased to baseline levels at ten to 12 months. Radioisotope uptake was comparable in the cemented and cementless groups, but was highly variable in individual patients and in each of the follow-up periods. A single postoperative bone scan cannot differentiate component loosening from early bone remodeling. Sequential bone scans, as a supplement to the clinical examination and conventional radiography, may prove useful in the diagnosis of TKA failure.

  8. Role of bone scan in rheumatic disease

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2003-06-01

    Rheumatic diseases can be categorized by pathology into several specific types of musculoskeletal problems, including synovitis (e.g. rheumatoid arthritis), enthesopathy (e.g. ankylosing spondylitis) and cartilage degeneration (e.g. osteoarthritis). Skeletal radiographs have contributed to the diagnosis of these articular diseases, and some disease entities need typical radiographic changes as a factor of the diagnostic criteria. However, they sometimes show normal radiographic findings in the early stage of disease, when there is demineralization of less than 30-50%. Bone scans have also been used in arthritis, but not widely because the findings are nonspecific and it is thought that bone scans do not add significant information to routine radiography. Bone scans do however play a different role than simple radiography, and it is a complementary imaging method in the course of management of arthritis. The image quality of bone scans can be improved by obtaining regional views and images under al pin-hole collimator, and through a variety of scintigraphic techniques including the three phase bone scan and bone SPECT. Therefore, bone scans could improve the diagnostic value, and answer multiple clinical questions, based on the pathophysiology of various forms of arthritis.

  9. [Importance of bone scanning and osteoscintimetry for assessing development of acute haematogenic childhood osteomyelitis (author's transl)].

    Science.gov (United States)

    Fotter, R; Höllwarth, M

    1980-01-01

    Bone scanning with 99m-Tc-MDP is generally used for the early diagnosis of acute haematogenic childhood osteomyelitis. The combination of this method with radionuclide osteoscintimetry and the evaluation of the relative uptake ratio supply objective criteria for assessing the development of the disease. They permit statements as to the morphological and functional aspects of the disease and thus facilitate clinical assessment.

  10. Comparison of the clinic value of whole body MR diffusion weighted imaging and radionuclide bone scan in the diagnosis of skeletal metastasis of breast cancer%全身弥散加权成像与同位素骨扫描诊断乳腺癌骨转移对比研究

    Institute of Scientific and Technical Information of China (English)

    林建华; 谭理连; 何伟红; 黄勇; 李敏红; 邬恒夫

    2011-01-01

    目的:比较全身弥散加权成像(WB-DWI)、同位素骨扫描(radionuclide bone scan)技术在乳腺癌骨转移的应用价值.方法:40例经病理证实为乳腺癌的患者分别作WB-DWI及同位素骨扫描检查.WB-DWI检查使用反转恢复平面回波弥散序列行全身扫描,将骨骼系统分为3个区域,分别记录每个患者各区域WB-DWI阳性病例数.对所有WB-DWI及同位素骨扫描影像表现的乳腺癌转移例数及发生部位行统计学比较.结果:WB-DWI阳性病例为35例,共检出病灶数为146个;同位素骨扫描阳性病例为30例,共检出病灶数为141个,WB-DWI的病灶检出率高于同位素骨扫描;WB-DWI与同位素骨扫描诊断乳腺癌骨转移例数及发生部位无统计学差异.结论:WB-DWI检查无辐射,覆盖范围大,具有较高的敏感性,对乳腺癌骨转移早期筛查、诊断及预后评价方面具有重要的临床应用价值.%Objective:To compare the value of MR whole body diffusion weighted imaging (WB-DWI) and radionuclide bone scan (RN) in the detection of bone metastasis of breast cancer. Methods: Forty patients with pathology proved breast cancer were enrolled. All patients underwent MR WB-DWI and RN,inversion recovery echo-planar diffusion scan sequence from head to foot was used for WB-DWI. The skeletal system was divided into three regions and the positive cases were recorded patient by patient in each region. Chi-square test was performed in patients and regions of bone metastasis detected by WB-DWI and RN for comparison. Results: A total of 146 metastasis lesions in 35 patients were detected by WBDWI while 141 lesions in 30 patients by RN. The detection rate of WB-DWI was higher than that of RN. No statistic differences were assessed in the number and locations of the bone metastasis diagnosed by WB-DWI and RN. Conclusion: MR WBDWI has no radiation,large coverage and high sensitivity,which plays a significant role in early bone metastasis screening, diagnosis and

  11. POSSIBILITIES OF SYSTEMIC RADIONUCLIDE THERAPY IN PALLIATIVE TREATMENT OF P ATIENTS WITH METASTATIC BONES DISEASE

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2014-01-01

    Full Text Available The pain syndrome accompanying metastatic damage of bones, significantly reduces quality of patients life. In recent decades, medical practice implemented methods systemic radionuclide therapy of bone metastases using different radionuclides, which allows to stop both the pain and the progression of the disease. Results of their application give the grounds to consider the perspective development in nuclear medicine of the direction on treatment bone metastatic defeats by means of systemic radionuclide therapy.

  12. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L.; Wastie, M.L.; Forster, I

    2001-03-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of{sup 99}Tc{sup m}-MDP bone scintigraphy. METHOD: A retrospective study of all patients having a{sup 99}Tc{sup m}-MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  13. Computed tomography of the liver: evaluating focal defects on radionuclide liver-spleen scans

    Energy Technology Data Exchange (ETDEWEB)

    Djang, W.T.; Young, S.W.; Castellino, R.A.; Lantieri, R.

    1984-05-01

    A retrospective study was undertaken to evaluate the role of computed tomography (CT) in increasing the specificity of the abnormal radiocolloid liver-spleen scan. During a 12-month period, 124 patients with focal abnormalities on hepatic scintiscans were identified out of 523 consecutive radionuclide studies. Of these 124 patients, 38 had subsequent CT examination(s) of the liver. Of this group, 11 patients with suspected metastatic disease with focal defects on hepatic scintiscans had normal hepatic CT scans and subsequent negative follow-up for hepatic disease. False-positive radionuclide scan abnormalities, related either to anatomic variation in liver configuration or adjacent extrahepatic structures influencing the radiocolloid scan, are readily recognized and explained on the basis of CT examination.

  14. Quantitative bone scanning after asymptomatic Charnley arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Mullaji, A.B. (University Department of Orthopedic and Accident Surgery, Royal Liverpool University Hospital, Lierpool (United Kingdom)); Tood, R.C. (Department of Orthopedics, Black Notley Hospital, Braintree (United Kingdom)); Robinson, S. (Department of MedicaL Physics, Colchester General Hospital, Colchester (United Kingdom)); Critchley, M. (Department of Nuclear Medicine, Royal Liverpool University Hospital, Liverpool (United Kingdom))

    1994-06-01

    To establish the normal pattern of postoperative tracer uptake we performed 73 [sup 99m]technetium methylene disphosphonate scans following primary Charnley hip replacements for arthrosis in 68 patients without clinical, hematological and radiographic complications. The patients were divided into 7 subgroups according to the period, 6-24 months, between surgery and scan. There were 10-12 patients in each subgroup. A high-resolution gamma camera with a large filed of view was used. Ratios of uptake in each of 10 peri-prosthetic zones to normal bone were calculated. Femoral uptake was found to decrease in linear fashion from 6 to 12 months after surgery. Thereafter the uptake remained unaltered at levels nearly twice the normal ones in the greater trochanter and nearly 1.5 times in the lesser trochanter, returning to almost normal levels in other zones. Acetabular uptake remained elevated throughout. (au) (20 refs.).

  15. In vivo measurements of bone-seeking radionuclides. Progress report, September 1, 1977--February 28, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N.

    1978-11-01

    Progress is reported on the following research projects: estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull; contribution from radionuclides in the thoracic skeleton to in vivo measurements of activity in the lung; design and optimization characterictics of in vivo detection system; development of a calibration phantom structure for determining activity deposited in the thoracic skeleton; computer assisted in vivo measurements of internally deposited radionuclides using dual-crystal scintillation detectors; low energy, photon-emitting nuclides; reference spectra library; and in vivo measurements of exposed individuals. (HLW)

  16. Right ventricular function in patients with mitral valve disease; Evaluation by radionuclide blood pool scan

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Noriyasu, Toshiaki; Nakagawa, Tomio; Aono, Kaname; Yanagi, Hidekiyo; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao (Okayama Univ. (Japan). School of Medicine)

    1989-10-01

    Right ventricular function was studied in 13 patients with mitral valve stenosis (MS), 10 patients with mitral valve regurgitation (MR) and 10 patients after mitral valve replacement (MVR) with radionuclide blood pool scan. In MS, right ventricular end-diastolic and end-systolic volumes were larger than MVR. In MR, right ventricular ejection fraction (RVEF) was smaller and right ventricular end-systolic volume was larger than MVR. In both MS and MR, there was no significant linear correlation between RVEF and mean pulmonary arterial pressure (mPAP) at rest, but during exercise RVEF of patients with elevated mPAP decreased more than that of patients with normal mPAP. RVEF in patients with MS and MR was significantly decreased during exercise, while that in patients after MVR showed no significant change. Radionuclide blood pool scan seems to be useful for the evaluation of right ventricular function in mitral valve disease. (author).

  17. Cabozantinib Resolves Bone Scans in Tumor-Naïve Mice Harboring Skeletal Injuries

    Directory of Open Access Journals (Sweden)

    Michael G. Doran

    2014-10-01

    Full Text Available The receptor tyrosine kinase inhibitor cabozantinib (XL184, BMS-907351 Cometriq has displayed impressive clinical activity against several indications, culminating in its recent approval for medullary thyroid cancer. Among malignancies with tropism for the bone (prostate, breast, one striking feature of early clinical reports about this drug has been the rapid and complete resolution of bone scans, a phenomenon almost never observed even among therapies already shown to confer survival benefit. In castration-resistant prostate cancer, not all conventional response indicators change as dramatically posttreatment, raising the possibility that cabozantinib may impair the ability of bone-seeking radionuclides to integrate within the remodeling bone. To test this hypothesis, we surgically induced bone remodeling via physical insult in non–tumor-bearing mice and performed 18F-sodium fluoride (18F-NaF positron emission tomographic (PET and technetium 99m–methylene diphosphonate (99mTc-MDP single-photon emission computed tomographic (SPECT scans pre- and posttreatment with cabozantinib and related inhibitors. A consistent reduction in the accumulation of either radiotracer at the site of bone remodeling was observed in animals treated with cabozantinib. Given that cabozantinib is known to inhibit several receptor tyrosine kinases, we drugged animals with various permutations of more selective inhibitors to attempt to refine the molecular basis of bone scan resolution. Neither the vascular endothelial growth factor receptor (VEGFR inhibitor axitinib, the MET inhibitor crizotinib, nor the combination was capable of inhibiting 18F-NaF accumulation at known bioactive doses. In summary, although the mechanism by which cabozantinib suppresses radionuclide incorporation into foci undergoing bone remodeling remains unknown, that this phenomenon occurs in tumor-naïve models indicates that caution should be exercised in interpreting the clinical significance

  18. Diagnostic value of gallium and bone scans in evaluation of extrapulmonary coccidioidal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.; dos Sontos, P. A.; Lee, K.K.

    1980-04-01

    The value of /sup 67/Ga and methylene diphosphonate labeled with /sup 99m/Tc in detecting extrapulmonary lesions was evaluated in 12 patients with whom disseminated nonmeningeal coccidioidomycosis developed. Studies were performed with each radionuclide from 4 to 9 months after infection. Comparison of scintigraphy with radiography showed that eight of 14 osteolytic lesions identified by radiography were present on the bone and gallium scans; four were present only on the gallium scan, and two were undetected. Of 15 additional lesions present in both scanning procedures, eight were not present in matching roentgenograms and seven were in unstudied areas. Because nuclear scanning detected almost all lesions present in radiographs and demonstrated otherwise unrecognized lesions, scans should be performed in all patients in whom coccidioidal dissemination is suspected.

  19. Radionuclide Treatment with 153Sm-EDTMP is Effective for the Palliation of Bone Pain in the Context of Extensive Bone Marrow Metastases: A Case Report

    Directory of Open Access Journals (Sweden)

    Kalevi Kairemo

    2014-10-01

    Full Text Available Radionuclide therapy is widely used as an effective modality in the management of bone pain. The main indication for this treatment is symptomatic bone metastases, confirmed by bone scintigraphy. We present a case of small cell lung cancer (SCLC stage T4N2M1b, with a good metabolic response to systemic therapy and radiotherapy of the primary tumor and locoregional disease, which became metabolically less active and remarkably smaller in size (reduction to 1/6 of the original volume. In spite of the good overall response, the patient developed a syndrome with severe bone pain and had progression in the bone marrow metastases, confirmed by 18F-FDG PET/CT. The patient received 153Sm-EDTMP treatment with a good clinical response. However, in the whole body bone scan with the therapeutic dose, there was no visual evidence of bone metastasis. Retrospectively, by drawing the region of interest, it was possible to identify one metastatic site. The possible mechanisms of the efficacy of this treatment modality, in this specific setting, are also discussed.

  20. Radionuclide Treatment with 153Sm-EDTMP is Effective for the Palliation of Bone Pain in the Context of Extensive Bone Marrow Metastases: A Case Report

    Science.gov (United States)

    Kairemo, Kalevi; Rasulova, Nigora; Suslaviciute, Justina; Alanko, Tuomo

    2014-01-01

    Radionuclide therapy is widely used as an effective modality in the management of bone pain. The main indication for this treatment is symptomatic bone metastases, confirmed by bone scintigraphy. We present a case of small cell lung cancer (SCLC) stage T4N2M1b, with a good metabolic response to systemic therapy and radiotherapy of the primary tumor and locoregional disease, which became metabolically less active and remarkably smaller in size (reduction to 1/6 of the original volume). In spite of the good overall response, the patient developed a syndrome with severe bone pain and had progression in the bone marrow metastases, confirmed by 18F-FDG PET/CT. The patient received 153Sm-EDTMP treatment with a good clinical response. However, in the whole body bone scan with the therapeutic dose, there was no visual evidence of bone metastasis. Retrospectively, by drawing the region of interest, it was possible to identify one metastatic site. The possible mechanisms of the efficacy of this treatment modality, in this specific setting, are also discussed. PMID:27408870

  1. Role of computed tomography and radionuclide scintigraphy in the localization of osteomyelitis in flat bones

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Conway, J.J.; Poznanski, A.K.; Tachdjian, M.O.; Dias, L.S.; Kelikian, A.S.

    1985-03-01

    The combined use of radionuclide scintigraphy and computed tomography is recommended for evaluating children with laboratory and clinical data suggestive of flat bone osteomyelitis despite normal conventional radiographs. In addition, computed tomography may be helpful in the presence of abnormal radiographs in determining the exact location of the focus of osteomyelitis and the most suitable route for appropriate drainage or to obtain culture material.

  2. Experimental fracture healing: evaluation using radionuclide bone imaging: concise communication. [/sup 99m/Tc-methylene diphosphonate; rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Gumerman, L.W.; Fogel, S.R.; Goodman, M.A.; Hanley, E.N. Jr.; Kappakas, G.S.; Rutkowski, R.; Levine, G.

    1978-12-01

    Radionuclide bone imaging was performed in a rabbit model to observe the course of fracture healing and to establish criteria for distinguishing nonunion and delayed healing from normal healing. Sequential gamma-camera images (with pinhole collimator) were collected and subjected to computer analysis. Five groups were established: (a) control--immobilization; (b) control--immobilization plus periosteal stripping; (c) simple fracture--osteotomy; (d) delayed union--osteotomy plus periosteal stripping; and (e) nonunion--osteotomy, periosteal stripping and polymethyl methacrylate interposed between fracture fragments. Histographic representation of absolute count rates along rabbit tibias followed a predictable pattern in the simple-fracture and delayed-union groups. They differed only in the time of appearance of phases. The non-union group demonstrated no recognizable sequential pattern. In this experimental model, serial bone scanning the quantitative data analysis has shown potential for indicating the course of healing in fractures and for serving as a guide to treatment.

  3. Brown Tumor Shown Flare Phenomenon On Bone Scan After Parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kwang Ho; Park, Seol Hoon; Baek, So Ra; Chae, Sun Young; Koh, Jung Min; Kim, Jae Seung; Moon, Dae Hyuk; Ryu, Jin Sook [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2009-10-15

    Brown tumor is the benign bone lesion consists of woven bone and fibrous tissue without matrix, which develop due to chronic excessive osteoclastic activity such as hyperparathyroidism. Usually they appear with normal uptake or occasionally focally increased uptake on bone scan. We present a case with brown tumor shown more increased uptake and more number of lesions on bone scan after parathyroidectomy, and lesser increased uptake on serial bone scans without any other treatment through several months. This finding is thought to be similar to 'flare phenomenon' which is occasionally seen after treatment of metastatic bone lesions of malignant cancer, and may represent curative process of brown tumor with rapid normal bone formation.

  4. Bone scintigraphy and osteo-articular tuberculosis in transplant patients: a study of 50 bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Coulaud, J.P.; Mechali, D.; Morau, G. (Hopital Claude-Bernard, Paris (France))

    1982-01-01

    Bone scintigraphy with 99 m technecium labelled phosphorus compounds was achieved in 50 west Africans migrant workers in Paris. Bone and joint tuberculosis was assumed in 20 cases. In 5 of these 20 cases, bone scan, but not X-ray, showed abnormalities, and in 4, bone scan disclosed more localisations than X-rays. In 7 cases, yet, bone scan was normal, with major osteolytic X-rays lesions in 3 cases, minor in 2 cases, and isolated cold abcesses in two more cases: these means 7 false-negative results. Among the 30 other cases, 29 were considered as mechanical vertebral pathology, and 1 sacro-iliitis Brucellosis. Bone scan was normal in 28 cases the 2 others are unexplained false-positive. Although non-specific and not completely reliable, we think that bone-scanning is useful in bone-tuberculosis check-up, especially to obtain early diagnosis and detect multifocal localisations.

  5. Is there a place for radionuclide bone scintigraphy in the ...

    African Journals Online (AJOL)

    1996-05-05

    May 5, 1996 ... Departments of Orthopaedic Surgery, Nuclear Medicine and Surgery. (Trauma Unit), Groote ... imaging was 67.2 hours, the range being 8 - 266 hours. .... Garvie NW, Khan MA, ACotery OM_ Isotope bone Imagmg In suspected.

  6. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded...... as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones....

  7. Tumoral calcinoses in bone scanning: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Cook, P. [Royal Prince Alfred Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-03-01

    Full text: Tumoral calcinosis (TC) is a rare disorder characterised by hyperphosphateamia, normocalceamia and calcified para-articular masses as seen on X-ray. At present, an inborn error of phosphorous metabolism is accepted as the primary cause. Symptoms include pain, swelling, infection and single- or multi-focal lesions. Radionuclide imaging was recently described as the most reliable and simplest method for detection, localisation and assessment of the calcific masses. Bone scintigraphy may demonstrate unsuspected masses even when clinical examination is negative. It is also useful in assessing the effects of surgery and therapy. A 55-year-old male with an 18-year history of TC presented to our department on two occasions. He was first referred to assess the extent of his calcinosis. He had known involvement of the hands, shoulders and pelvis, with little restriction of movement. He had a 6-8 year history of polio which was currently stable. Seven years later he again presented to our department, this time for the evaluation of a suspected fractured hip. On both occasions 800 MBq of {sup 99}mTc-MDP was injected IV and whole body and planar images were obtained at three hours. In the second study, additional dynamic and blood pool images were obtained over the anterior aspect of both hips. Both scans were grossly abnormal and typical of the appearance of widespread TC or calcinosis universalis. Multiple areas of extra osseous uptake involving subcutaneous tissue and muscle of the hands, para-articular regions of both elbows, shoulders and hips were seen and confirmed by X-ray. Localised abnormalities were noted involving left lower neck, left forearm and left foot. Marked progression of the disease was seen in the region of the left shoulder on the second scan. No abnormalities were noted within the skeleton itself. Neither the dynamic nor blood pool phase of the study demonstrated significant hyperaemia in the region of the left proximal femur. Although the

  8. Use of Gamma Correction Pinhole Bone Scans in Trauma

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Youg Whee [Sung Ae Hospital, Seoul (Korea, Republic of); Chung, Youg An; Park, Jung Mee [Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2012-03-15

    {sup 99}mTc hydroxydiphosphonate (HDP) bone scanning is a classic metabolic nuclear imaging method and the most frequently performed examination. Clinically, it has long been cherished as an indispensable diagnostic screening tool and for monitoring of patients with bone, joint, and soft tissue diseases. The HDP bone scan, the pinhole scan in particular, is known for its ability to detect increased, decreased, or defective tracer uptake along with magnified anatomy. Unfortunately, however, the findings of such uptake changes are not specific in many traumatic bone disorders, especially when lesions are minute and complex. This study discusses the recently introduced gamma correction pinhole bone scan (GCPBS), emphasizing its usefulness in the diagnosis of traumatic bone diseases including occult fractures; and fish vertebra. Indeed, GCPBS can remarkably enhance the diagnostic feasibility of HDP pinhole bone scans by refining the topography, pathologic anatomy, and altered chemical profile of the traumatic diseases in question. The fine and precise depiction of anatomic and metabolic changes in these diseases has been shown to be unique to GCPBS, and they are not appreciated on conventional radiographs, multiple detector CT, or ultrasonographs. It is true that MR imaging can portray proton change, but understandably, it is a manifestation that is common to any bone disease.

  9. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration. [Preoperative scanning

    Energy Technology Data Exchange (ETDEWEB)

    Heslinga, J.M.; Pauwels, E.K.J.; Zwaveling, A. (Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis)

    1982-06-05

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period.

  10. Radionuclide conjugates of calcitonin for imaging bone disease and cancer

    Energy Technology Data Exchange (ETDEWEB)

    Greenland, William Edward Peverell

    2002-07-01

    Salmon calcitonin (sCt) is a peptide with a higher affinity for human calcitonin receptors (hCtR) than human calcitonin. It has been used for treating osteoporosis, Paget's disease and bone pain. High levels of hCtRs are expressed on osteoclasts, bone metastases and primary breast and prostate cancers. The peptide was chosen for radiolabelling as a possible imaging agent. Direct labelling with {sup 99m}Tc via simultaneous reduction of the indigenous disulfide bond and {sup 99m}TcO{sub 4}{sup -} (VII) with the water soluble phenyl phosphine (TPPDS) was performed. The radiolabelled peptide was not suitable for use as a radiopharmaceutical due to the heterogeneity of the product as observed by reverse phase HPLC and due to poor binding to the human breast cancer cell line MCF7. The electospray MS suggested a {sup 99}Tc-TPPDS (III) core instead of the expected {sup 99}Tc=O (V) core. Normal sCt has 3 conjugatible primary amines leading to a mixture of 8 possible products. A sCt analogue (sCtA) with a single primary amine was produced and conjugated to the chelator TETA to produce a single conjugated species. The sCtA-TETA was labelled with cold Cu and characterised by electospray MS. The monodentate ligand Hynic was synthesised directly into the peptide using N-{alpha}-Fmoc-N-{epsilon}-(Hynic-Boc)-Lys a novel orthogonally protected amino acid. The peptide was labelled with {sup 99m}Tc with tricine coligands. The radiolabelled peptide produced a single peak as observed by reverse phase HPLC and bound to MCF7 cell in a specific manner. The electospray MS suggested that one of the tricine coligands is lost due to the heating effect and possibly replaced by an adjacent histidine acting as a ternary ligand. The sCtLys{sup 18}-Hynic{sup 99m}Tc(tricine){sub 2} labelled peptide is the lead radiolabelled peptide and could be used for a normal biodistribution animal study, followed by clinical evaluation in humans. (author)

  11. The Usefulness of Bone Scan in Electric Burns

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo [Hanil Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  12. [Scanning electron microscopy of heat-damaged bone tissue].

    Science.gov (United States)

    Harsanyl, L

    1977-02-01

    Parts of diaphyses of bones were exposed to high temperature of 200-1300 degrees C. Damage to the bone tissue caused by the heat was investigated. The scanning electron microscopic picture seems to be characteristic of the temperature applied. When the bones heated to the high temperature of 700 degrees C characteristic changes appear on the periostal surface, higher temperatura on the other hand causes damage to the compact bone tissue and can be observed on the fracture-surface. Author stresses the importance of this technique in the legal medicine and anthropology.

  13. Metastatic bone lesions in children, current assessment of radionuclide skeletal survey

    Energy Technology Data Exchange (ETDEWEB)

    Zucker, J.M.; Gongora, R.; Michon, J.; Gongora, G.; Quintana-Margulis, E. (Institut Curie, Paris (France))

    Bone scintigraphy is more sensitive than radiographic skeletal survey in early diagnosis of bone metastases from pediatric solid tumors. Organic phosphorus compounds of labelled 99 m technetium are currently the far most used, and the pattern of imaging is compared to normal skeletal distribution of the radionuclide in childhood. From the most important series of the recent literature and their own experience, the authors ask the value of the procedure and describe overall results: a reliable diagnosis of bone metastases is done in 25 to 50% of the metastatic patients several weeks or months earlier than by radiographs: false positive are rarely misleading if usual pitfalls have been discarded: false negative are encountered in approximately 10% of the cases: post-therapeutic changes may be confusing. Some more details are given for neuroblastoma in which ''cold'' metastases and symetrical long bone's metaphysis involvement may display a misleading aspect. The selective uptake of the tracer by the primary is also underlined in this tumor. Finally indications of radionuclide skeletal survey, -at diagnosis and during and after the treatment-, are proposed for patients at risk amongst children with malignant solid tumors.

  14. Clinical analysis of bone scanning in solitary lesion

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A rational analysis procedure for solitary lesions on whole bone scan-ning was offered. This study was undertaken to analyze retrospectively solitary le-sions which obtained final diagnose through the following aspects: (1) diagnosis ofbone metastasis, (2) the incidence of bone metastasis in different tumor, (3) the mostpossible lesion sites indicating bone metastasis, (4) morphological analysis of solitarylesions. The results are: (1) The incidence of solitary lesions in 2465 cases on wholebone scanning is 15.3%. (2) The rate of bone metastasis is 24.8% in 282 patientswith primary malignancy. The rate of bone metastasis is 6.3% in 64 patients withoutprimary malignancy, and the total diagnostic rate of bone metastasis is 21.4% in 346patients. (3) In patients with primary malignancy, the incidence of bone metastasis ofsolitary lesions is as follows respectively: bronchi cancer 36.1%(22/61); breast cancer23.8%(20/84); prostate gland 17.2%(5/29); other urinary system cancer 22.2%(4/18):G.I. system cancer 16.9%(10/59); others 29.0%(9/31). There is no significant differ-ence in different cancer. (4) In patients without primary malignancy, 93.7%(60/64) ofsolitary lesions are benign. (5) From anatomical point of view, we found the diagnos-tic rate of bone metastasis is as follow: 30% in spine; 34.2% in pelvis; 36.4% in skull;10.8% in other bones. There are significant differences in four groups. It is concludedthat: (1) The diagnostic rate of bone metastasis in solitary lesions is 21.4%. (2) Themost possible solitary lesions indicating osseous tumor spread are at spine, pelvic andskull. (3) Special attention to "cold" and streak like lesions should be paid. (4) Aclinical analysis procedure for diagnosis of solitary lesions has been summarized outhere.``

  15. FEATURE EXTRACTION OF BONES AND SKIN BASED ON ULTRASONIC SCANNING

    Institute of Scientific and Technical Information of China (English)

    Zheng Shuxian; Zhao Wanhua; Lu Bingheng; Zhao Zhao

    2005-01-01

    In the prosthetic socket design, aimed at the high cost and radiation deficiency caused by CT scanning which is a routine technique to obtain the cross-sectional image of the residual limb, a new ultrasonic scanning method is developed to acquire the bones and skin contours of the residual limb. Using a pig fore-leg as the scanning object, an overlapping algorithm is designed to reconstruct the 2D cross-sectional image, the contours of the bone and skin are extracted using edge detection algorithm and the 3D model of the pig fore-leg is reconstructed by using reverse engineering technology. The results of checking the accuracy of the image by scanning a cylinder work pieces show that the extracted contours of the cylinder are quite close to the standard circumference. So it is feasible to get the contours of bones and skin by ultrasonic scanning. The ultrasonic scanning system featuring no radiation and low cost is a kind of new means of cross section scanning for medical images.

  16. A negative bone scan leads to an unusual diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    O`Brien, L. [Royal Brisbane Hospital, Herston, QLD (Australia). Department of Nuclear Medicine

    1998-03-01

    Full text: A bone scan looking for osteomyelitis or a more sinister pathology was performed on a 7-year-old boy with Von Willebrand``s disease. He presented with symptoms of pain in the left groin and a lump, although there had been no history of direct trauma, and an X-ray report stating that there was an irregular ill-defined area of bony destruction seen in the lower aspect of the left ischium. Blood pool images of the pelvis were acquired soon after an injection of MDP and three hours later a whole body bone scan was done. Results of the bone scan showed that the radiolucent lesion in the left ilium seen on the plain radiographs was not metabolically active on the technetium MDP study. Features compatible with a response to an intraosseous or sub-periosteal haematoma were seen when reviewing the original X-rays and, as there was a spontaneous resolution of the patient``s symptoms, this was considered to be the diagnosis. This study shows that a negative bone scan, which rules out an active bone lesion, is of value in making a diagnosis when used in conjunction with X-rays and a knowledge of the patient``s history.

  17. Confocal laser scanning microscopy in study of bone calcification

    Energy Technology Data Exchange (ETDEWEB)

    Nishikawa, Tetsunari, E-mail: tetsu-n@cc.osaka-dent.ac.jp [Department of Oral Pathology, Osaka Dental University, Osaka (Japan); Kokubu, Mayu; Kato, Hirohito [Department of Oral Pathology, Osaka Dental University, Osaka (Japan); Imai, Koichi [Department of Biomaterials, Osaka Dental University, Osaka (Japan); Tanaka, Akio [Department of Oral Pathology, Osaka Dental University, Osaka (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer High-magnification images with depth selection, and thin sections were observed using CLSM. Black-Right-Pointing-Pointer The direction and velocity of calcification of the bone was observed by administration of 2 fluorescent dyes. Black-Right-Pointing-Pointer In dog femora grafted with coral blocks, newly-formed bone was observed in the coral block space with a rough surface. Black-Right-Pointing-Pointer Twelve weeks after dental implant was grafted in dog femora, the space between screws was filled with newly-formed bones. - Abstract: Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 {mu}m/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  18. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    Science.gov (United States)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  19. Osteopetrosis: Radiological & Radionuclide Imaging

    Science.gov (United States)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent 99mTc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis. PMID:25589808

  20. Osteopetrosis: radiological & radionuclide imaging.

    Science.gov (United States)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent (99m)Tc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis.

  1. Synovial visualization during Tc-99m MDP bone scanning in septic arthritis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Yon, J.W. Jr.; Spicer, K.M.; Gordon, L.

    1983-06-01

    During Tc-99m medronate (MDP) bone scintigraphy, visualization of the synovium during blood flow and blood pool phases was present in a patient with septic arthritis of the left knee. Inflammation with hyperemia of the synovium was the cause for radionuclide localization, which was enhanced by the large photon-deficient effusion distending the suprapatellar bursa. The synovium was not seen on delayed images after redistribution of the radionuclide from blood pool to bone phase.

  2. Radionuclide whole body bone imaging analysis of 189 cases of lung cancer patients with bone metastases%189例肺癌骨转移患者核素全身骨显像分析

    Institute of Scientific and Technical Information of China (English)

    吴国; 王朝晖; 李滢

    2011-01-01

    目的 探讨肺癌骨转移患者核素全身骨显像的临床诊断价值.方法 选取行核素全身骨显像分析的肺癌骨转移患者189例为研究对象,分析骨转移部位、发生率与肺癌病理类型的关系.结果 肺腺癌骨转移发生率较其他类型多;骨转移部位以胸部、中轴骨为主.结论 肺癌骨转移患者的核素全身骨显像分析可以准确判断骨转移的部位和发生率,具有较高的临床诊断价值.%Objective To analyze the result of radionuclide bone scan with whole body in 189 lung cancer patients with bone metastases. Methods 189 cases of lung cancer patients with bone metastasis in this hospital from January 2009 to March 2011 were selected for the study. Bone metastases and the relationship of lung cancer incidence and pathological types were analyzed. Results Bone metastasis of adenocaicinoma was more than the other pathological types of lung cancer. Bone metastatic was mainly concentrated in the chest or axial skeleton. Conclusion Analysis of radionuclide whole body bone imaging in lung cancer patients with bone metastases can accurately determine the site of bone metastasis, which has great clinical value.

  3. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    Science.gov (United States)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2012-01-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone’s mechanical strength and structural parameters, i.e., bulk Young’s modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young’s modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone’s structural integrity. PMID:23976803

  4. Technetium bone scanning as an aid in the diagnosis of atypical acute osteomyelitis in children

    Energy Technology Data Exchange (ETDEWEB)

    Letts, R.M.; Afifi, A.; Sutherland, J.B.

    1975-06-01

    Technetium bone scanning is a simple, safe and accurate method for the diagnosis of acute osteomyelitis in children whose presenting clinical findings are atypical of bone infection. Bone scanning was effective in the localization of the exact site of osteomyelitis, thus facilitating needle aspiration as well as subsequent surgical decompression. Technetium bone scanning is a diagnostic technique for determining bone infection in children who are unable to communicate adequately or in those whose signs have been modified by previous inadequate antibacterial therapy.

  5. Bone and gallium scans in mastocytosis: correlation with count rates, radiography, and microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ensslen, R.D. (Cross Cancer Inst., Edmonton, Alberta); Jackson, F.I.; Reid, A.M.

    1983-07-01

    Mastocytosis (urticaria pigmentosa) was proven in a patient suffering from severe back pain. A bone scan showed diffusely increased bone activity. Count rates were also abnormally elevated over several areas of the skeleton. Radiographs were consistent with mastocytosis in bone.

  6. The Findings of {sup 99m}Tc-MDP Bone Scan in Primary malignant Bone Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, In Young; Lee, Kung Han; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kang, Heung Sik; Lee, Sang Hoon; Lee, Han Koo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-03-15

    Tc-99m-MDP bone scan was performed in 31 patients with primary malignant bone tumors, 22 patients with osteogenic sarcoma, 5 patients with chondrosarcoma and 4 patients with Ewing's sarcoma. The findings were classified by isotope intensity of accumulation in tumor as grade 1 to 3, overall pattern of isotope distribution in tumor as grade 1 to 3, and distortion of bony outline as grade 1 to 3. Histologic classifications were correlated with scan findings in 22 patients with osteogenic sarcoma. The results were as follows. 1) In 22 patients with osteogenic sarcoma, markedly increased isotope intensity higher than sacroiliac joint with patchy areas of decreased intensity and severe bony distortion were found in 16 patients. The correlations between histologic classification and scan findings were not discovered. 2) In 5 patients with chondrosarcoma, mildly increased isotope intensity with patchy areas of increased intensity and mild bony distortion were found in 4 patients. 3) In 4 patients with Ewing's sarcoma, markedly increased homogenous intensity with moderate bony distortion were found in 3 patients. Conclusively there were common findings in each 3 primary malignant bone tumors and Tc-99m-MDP bone scan was complemented with radiologic studies in differentiating primary malignant bone tumors.

  7. Comparison of computed tomography and radionuclide scanning for detection of brain metastases in small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Crane, J.M.; Nelson, M.J.; Ihde, D.C.; Makuch, R.W.; Glatstein, E.; Zabell, A.; Johnston-Early, A.; Bates, H.R.; Saini, N.; Cohen, M.H.

    1984-09-01

    Neurologic history and examination, radionuclide brain scans (RN), and computed tomographic brain scans (CT) were performed at diagnosis and sequentially in 153 consecutive patients with small cell lung cancer (SCLC) to assess the sensitivity and accuracy of these screening methods and to determine whether the early detection of brain metastases influences survival. CT scans (sensitivity, 98%; positive predictive accuracy, 98%) were superior to RN scans (sensitivity, 71%; positive predictive accuracy, 86%) in patients with or without neurologic signs or symptoms. However, CT scans were positive in only 6% of asymptomatic patients at diagnosis and 13% of asymptomatic patients after systemic therapy. Brain metastases detected by CT scan were the sole site of extensive-stage disease in 6% of patients at diagnosis. Despite the enhanced ability of CT scans to detect asymptomatic lesions, survival after therapeutic cranial irradiation was similar for asymptomatic and symptomatic patients. The results suggest that CT brain scans should be used routinely in SCLC patients with neurologic signs or symptoms, at diagnosis (when treatment decisions are based on stage), and at six-month intervals in patients with prior brain metastases and in whom erratic follow-up is likely.

  8. Magnification bone scan of knees for knee pain evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Hoon; Park, Chan H.; Yoon, Seok Nam; Hwang, Kyung Hoon [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    2001-07-01

    Knee pain is one of the common complaints of patients seen in our orthopedic clinic. Routine anterior and posterior views of whole body bone scan (WBBS) is often not sufficient in the evaluation of these patients. An ideal bone scan using pinhole collimator or single photon emission tomography (SPECT), however, is impractical and time consuming in busy nuclear medicine department with limited resources. Therefore, the aim of the study is to assess limited bone scan of knees with magnification (LNSKM) for knee pain evaluation. Technical aspect of LBSKM and diagnostic efficacy are discussed on this poster. Adult patients with knee pain were reffered for LBSKM from an orthopedic surgen specializing knees. Four hundred fifteen LBSKMs were performed since 1999. patients were given 740 MBq (20mCi) Tc-99m MDP intravenously and 3 hours later LBSKM was performed using a low energy high resolution parallel hole collimator and Siemens Orbitor camera. (Simens medical systems. Inc., Hoffman Estates, III., USA). Anterior view of the knees was taken for 5 min, without magnification and both lateral views of symptomatic knees were obtained with electronic magnification (1.25, upto 2.0) for 8 min each. Disease processes such as DJD, traumatic arthritis, P-F tendonitis, SONK, meniscus tear are detected and illustrated along with normal knee scan finding. We believe LBSKM may not be as good as SPECT or pinhole imaging of the knees in the evaluation of knee pain but superior to routine WBBS in the nuclear medicine department with limited resources of instrumentation and manpower.

  9. Expert System for Bone Scan Interpretation Improves Progression Assessment in Bone Metastatic Prostate Cancer.

    Science.gov (United States)

    Haupt, Fabian; Berding, Georg; Namazian, Ali; Wilke, Florian; Böker, Alena; Merseburger, Axel; Geworski, Lilli; Kuczyk, Markus Antonius; Bengel, Frank Michael; Peters, Inga

    2017-04-01

    The bone scan index (BSI) was introduced as a quantitative tool for tumor involvement in bone of patients with metastatic prostate cancer (mPCa). The computer-aided diagnosis device for BSI analysis EXINIbone(BSI) seems to represent technical progress for the quantitative assessment of bone involvement. But it is not yet clear if the automated BSI (aBSI) could contribute to improved evaluation of progression in patients under antiandrogens or chemotherapy in contrast to the visual interpretation and/or conventional biomarkers such as the prostate-specific antigen (PSA). In 49 mPCa patients, bone scans were performed initially and during different therapy courses. Scans were evaluated visually and by the artificial-neural-network-based expert system EXINIbone(BSI). Progression of metastatic bone involvement was defined according to the Prostate Cancer Clinical Trials Working Group 2 (PCWG2) criteria in the visual interpretation. The computer-assisted interpretation was based on different cutoff values in relative changes of the aBSI. Additionally, assessments according to bone scanning were compared to changes in the PSA value as a potential surrogate for treatment response. Using a sensitive cutoff value (5% or 10%) for the relative aBSI increase led to significantly increased progression determination compared to the visual interpretation of bone scans (49% and 43% vs. 27%, p < 0.001). In 63% of the cases PSA and BSI changes matched, whereas in 18% progression was only indicated by the aBSI. A relative cutoff of 5% for the aBSI decrease could reclassify 47 serial scan pairs which were visually interpreted as stable into 22 progressive and 25 remissive scans. Distinct thresholds of the relative aBSI could help to better assess disease progression in mPCa patients. Manual corrections of the BSI values are not required in most cases. The aBSI could serve as a useful additional parameter for therapy monitoring in mPCa patients in the future.

  10. Scanning electron microscopy of erythropoietin-stimulated bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Leblond, P.F. (Hospital of St. Sacrement, Quebec); Chamberlain, J.K.; Weed, R.I.

    1975-01-01

    This work describes and illustrates the scanning electron microscopic modifications observed in the femoral bone marrow of normal mice 72 hours after a single injection of partly purified sheep erythropoietin and of mice afflicted with a chronic congenital hemolytic anemia analogous to the disease Hereditary Spherocytosis in man. In acordance with previous transmission electron microscopic studies, the observations are consistent with an effect of erythropoietin both on the frequency of cell migration across the normally intact marrow sinus endothelium and on the morphology of sinus adventitial cells. It is suggested that these ultrastructural modifications may be responsible for the greater patency of the marrow-blood barrier under erythropoietin stimulation.

  11. Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

    Energy Technology Data Exchange (ETDEWEB)

    Falchook, Aaron D. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Salloum, Ramzi G. [Department of Health Services Policy and Management, University of South Carolina, Columbia, South Carolina (United States); Hendrix, Laura H. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Chen, Ronald C., E-mail: ronald_chen@med.unc.edu [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Cecil G. Sheps Center for Health Services Research, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States)

    2014-06-01

    Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

  12. A study of bone uptake according to renal function in the whole body bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong In; Jang, Dong Gun [Dept. of Nuclear Medicine, Dongnam Institute of Radiological and Medical Sciences Cancer Center, Busan (Korea, Republic of); Park, Cheol Woo [Dept. of Radiological Technology Dong-Eui Institute of Technology, Busan (Korea, Republic of)

    2013-12-15

    Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to 99mTc uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

  13. How Is Bone Cancer Diagnosed?

    Science.gov (United States)

    ... the x-ray, but only a biopsy can absolutely determine that. A chest x-ray is often ... may find disturbing. Some places provide headphones with music to block this out. Radionuclide bone scans This ...

  14. Scanning electron microscopy of human cortical bone failure surfaces.

    Science.gov (United States)

    Braidotti, P; Branca, F P; Stagni, L

    1997-02-01

    Undecalcified samples extracted from human femoral shafts are fractured by bending and the fracture surfaces are examined with a scanning electron microscope (SEM). The investigation is performed on both dry and wet (hydrated with a saline solution) specimens. SEM micrographs show patterns in many respects similar to those observed in fractography studies of laminated fiber-reinforced synthetic composites. In particular, dry and wet samples behave like brittle and ductile matrix laminates, respectively. An analysis carried out on the basis of the mechanisms that dominate the fracture process of laminates shows that a reasonable cortical bone model is that of a laminated composite material whose matrix is composed of extracellular noncollagenous calcified proteins, and the reinforcement is constituted by the calcified collagen fiber system.

  15. An Inflammatory Dentigerous Cyst Shows Rim Uptake on Bone Scan: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Son, Hye Joo; Jeong, Young Jin; Jeong, Jin Sook; Kang, Doyoung [Dong-A Univ. Medical Center, Busan (Korea, Republic of)

    2014-03-15

    Dentigerous cysts are developmental odontogenic jaw cysts, commonly manifesting in the 2nd and 3rd decades of life. This article presents an extremely rare case of dentigerous cyst showing increased uptake in the peripheral rim on bone scan. Herein, we discuss the clinical, radiographic, and histologic features of dentigerous cysts as well as the pathological mechanism underlying their activities on the bone scan. Bone scan was a sensitive tool for detecting the biologic activity of dentigerous cyst in our case.

  16. Radionuclide Bone Imaging Features of Bone Metastasis from 158 Patients of Esophageal Cancer%158例食管癌骨转移核素骨显像特征分析

    Institute of Scientific and Technical Information of China (English)

    丁忠旗; 张俊; 盛强; 姚圣华; 骆佩芳

    2012-01-01

    目的探讨食管癌骨转移患者的核素骨显像特征及临床应用。方法收集我院2007年1月至2011年12月接受全身骨显像的158例食管癌患者病历资料。对全身骨显像结果进行统计和分析,归纳食管癌患者骨转移显像特点。结果 158例食管癌患者骨转移发生率为17.72%(28/158),其中以脊柱及肋骨转移最为多见,发生率分别为89.29%(25/28),64.29%(18/28)。依据病理类型,鳞癌、腺癌、小细胞癌的骨转移发生率分别为13.83%(13/94),21.95%(9/41)和26.09%(6/23)。结论放射性核素骨显像对食管癌患者具有重要的临床意义,应作为治疗前后骨转移诊断和随访的常规检查手段。%Objective To investigate radionuclide bone imaging features and its clinical value in esophageal cancer patients with bone metastasis.Methods The medical records of 158 patients with esophageal cancer who accepted the whole body bone scan(WBS) from January 2007 to December 2011 in our hospital were collected.The WBS results were statistically analyzed,and the imaging features were summarized.Results The bone metastasis incidence of 158 cases of esophageal cancer patients was 17.72%(28/158).The spine and rib metastasis were the most common,the rate was 89.29%(25/28) and 64.29%(18/28),respectively.According to the pathological type,the bone metastasis incidence of squamous cell carcinoma,adenocarcinoma,small cell carcinoma was 13.83%(13/94),21.95%(9/41) and 26.09%(6/23),respectively.Conclusion Radionuclide bone imaging has important clinical value in patients with esophageal cancer.It should serve as a routine means of diagnosis and follow-up of bone metastases before or after treatment of patients.

  17. 放射性核素骨显像对乳腺癌骨转移的临床应用价值%Diagnostic value of 99Tcm-MDP radionuclide bone imaging in bone metastasis of breast cancer

    Institute of Scientific and Technical Information of China (English)

    黄之杰; 霍红艳; 李正勇; 王庆旭; 孙志勇

    2011-01-01

    目的 探讨乳腺癌骨转移SPECT的影像学表现.方法 回顾性分析了168例乳腺癌患者骨转移的影像学表现,SPECT选择99Tcm -MDP作为显像剂,综合分析乳腺癌骨转移性病变的SPECT扫描特点.结果 乳腺癌SPECT扫描以多样性表现为特点;SPECT影像检出率达94.0%,但其缺乏特异性.结论 放射性核素骨显像结合临床资料,能够早期发现骨转移病灶,为临床治疗提供有力的依据.%Objective To investigate the image of bone metastasis of breast cancer scanned by single photo emission computer tomography ( SPECT ). Methods The clinical data of 168 women with confirmed bone metastasis of breast cancer were retrospectively studied. They all received SPECT using 99Tcm- MDP as an imaging agent, and then the imaging features were analyzed and compared with X - ray, CT and MRI ones. Results SPECT image of bone metastasis of breast cancer was characterized by multiformity. Its sensitivity to bone metastasis was high ( 94.0% ) compared with that of X - ray ( 28.1% ), CT ( 56.7% ) and MRI ( 82.6% ), but the specificity- was poor. Conclusion 99 Tcm- MDP radionuclide bone imaging combined with clinical data can detect and localize bone metastasis early,and therefore provide evidences for tailored management.

  18. Fibromatosis of bone in children

    Energy Technology Data Exchange (ETDEWEB)

    Capusten, B.M.; Azouz, E.M.; Rosman, M.A.

    1984-09-01

    Radiographs, computed tomograms, and radionuclide bone scans were obtained preoperatively in three children with fibromatosis involving the bones and soft tissues of the extremities. Two of the children had identical scar-like bone lesions of the proximal tibia, which, to the author's knowledge, have not been reported before in this disease. The lesions recurred in two children.

  19. Radionuclide bone imaging in pediatrics%核素骨显像在儿科中的应用

    Institute of Scientific and Technical Information of China (English)

    丁小博; 金刚

    2008-01-01

    Radionuclide bone imaging is used as the diagnostic procedure of choice for diagnosis of bone and soft-tissue infection and can aid in the diagnosis of occult trauma without radiographic findings.There is a complimentary role in the assessment of a child with suspected non accidental injury.It also may provide a diagnosis that could be related to trauma,tumor,or inflammation in a child with unexplained bone pain or limp.Radionuclide bone imaging in children require careful attention to technique to obtain high quality diagnostic images.Routine whole-body imaging,magnification,additional views,and the use of single-photon emission computed tomography also are a routine part of this examination in children.Correlation with conventional radiographs is mandatory,and the judicious use of hybrid imaging with the addition of computed tomography may further improve diagnostic acumen,confidence and accuracy.New radiopharmaceuticals such as Na18F may also play a role in changing techniques for pediatric radionuclide bone imaging%放射性核素骨显像是诊断骨和软组织感染的选择性检查方法,不但有助于隐匿性骨折(X射线诊断阴性)的诊断,在评定小儿可疑非意外损伤方面起重要的补充作用,还可为无法解释的小儿骨痛或跛行提供诸如外伤、肿瘤、或炎症性病变的诊断依据.小儿核素骨显像要求精确的操作才能获得较清晰的诊断图像,常规全身骨显像、缩放比例、附加视图及单光子发射型计算机体层摄影术的使用等都是小儿检查的常规内容,联合CT的融合图像更进一步提高诊断的灵敏度、可信度和精确度.新的放射性药物如Na18F可能在不断更新变化的儿科骨显像技术中起重要作用.

  20. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Sundberg, S.B.; Savage, J.P.; Foster, B.K. (Adelaide Childrens Hospital (Australia))

    1989-09-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis.

  1. Preliminary results of automated removal of degenerative joint disease in bone scan lesion segmentation

    Science.gov (United States)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Auerbach, Martin; Goldin, Jonathan; Henkel, Keith; Banola, Ashley; Morris, Darren; Coy, Heidi; Brown, Matthew S.

    2013-03-01

    Whole-body bone scintigraphy (or bone scan) is a highly sensitive method for visualizing bone metastases and is the accepted standard imaging modality for detection of metastases and assessment of treatment outcomes. The development of a quantitative biomarker using computer-aided detection on bone scans for treatment response assessment may have a significant impact on the evaluation of novel oncologic drugs directed at bone metastases. One of the challenges to lesion segmentation on bone scans is the non-specificity of the radiotracer, manifesting as high activity related to non-malignant processes like degenerative joint disease, sinuses, kidneys, thyroid and bladder. In this paper, we developed an automated bone scan lesion segmentation method that implements intensity normalization, a two-threshold model, and automated detection and removal of areas consistent with non-malignant processes from the segmentation. The two-threshold model serves to account for outlier bone scans with elevated and diffuse intensity distributions. Parameters to remove degenerative joint disease were trained using a multi-start Nelder-Mead simplex optimization scheme. The segmentation reference standard was constructed manually by a panel of physicians. We compared the performance of the proposed method against a previously published method. The results of a two-fold cross validation show that the overlap ratio improved in 67.0% of scans, with an average improvement of 5.1% points.

  2. Unusual bone-scan findings in acute osteomyelitis: case report. [/sup 99m/Tc tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Russin, L.D.; Staab, E.V.

    1976-07-01

    In osteomyelitis, bone-scan findings precede the appearance of bone changes on radiographs. In cases where focal ischemia occurs, the earliest scan finding may be a cold area that later becomes hot as active periostitis develops.

  3. Combined bone scintigraphy and indium-111 leukocyte scans in neuropathic foot disease

    Energy Technology Data Exchange (ETDEWEB)

    Schauwecker, D.S.; Park, H.M.; Burt, R.W.; Mock, B.H.; Wellman, H.N.

    1988-10-01

    It is difficult to diagnose osteomyelitis in the presence of neurotrophic osteoarthropathy. We performed combined (99mTc)MDP bone scans and indium-111 (111In) leukocyte studies on 35 patients who had radiographic evidence of neuropathic foot disease and clinically suspected osteomyelitis. The (111In)leukocyte study determined if there was an infection and the bone scan provided the anatomic landmarks so that the infection could be localized to the bone or the adjacent soft tissue. Seventeen patients had osteomyelitis and all showed increased (111In)leukocyte activity localized to the bone, giving a sensitivity of 100%. Among the 18 patients without osteomyelitis, eight had no accumulation of (111In)leukocytes, seven had the (111In)leukocyte activity correctly localized to the soft tissue, two had (111In)leukocyte activity mistakenly attributed to the bone, and one had (111In)leukocyte accumulation in a proven neuroma which was mistakenly attributed to bone. These three false-positive results for osteomyelitis reduced the specificity to 83%. Considering only the 27 patients with a positive (111In)leukocyte study, the combined bone scan and (111In)leukocyte study correctly localized the infection to the soft tissues or bone in 89%. Uninfected neurotrophic osteoarthropathy does not accumulate (111In)leukocytes. We found the combined bone scan and (111In) leukocyte study useful for the detection and localization of infection to soft tissue or bone in patients with neuropathic foot disease.

  4. Whole Body Bone Scan Findings after High Intensity Focused Ultrasound (HIFU) Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ye Young; O, Joo Hyun; Sohn, Hyung Sun; Choi, Eun Kyoung; Yoo, Ik Dong; Oh, Jin Kyoung; Han, Eun Ji; Jung, Seung Eun; Kim, Sung Hoon [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2011-12-15

    This study aims to examine the findings of {sup 99mT}c diphosphonate bone scans in cancer patients with a history of HIFU treatment. Bone scan images of patients with a history of HIFU treatment for primary of metastatic cancer from January 2006 to July 2010 were retrospectively reviewed. Cases of primary bone tumor or HIFU treatment reaching only the superficial soft tissue layer were excluded. Bone scan images of 62 patients (26 female, 36 male; mean age 57{+-}9 years) were studied. HIFU treatment was performed in the liver (n=40), pancreas (n=40), pancreas (n=16), and breast (n=6). Mean interval time between HIFU treatment and bone scan was 106{+-}105 days (range: 1-572 days). Of 62 scans, 43 showed diffusely decreased uptake of bone within the path of HIFU treatment: antero axillary and/or posterior arcs of right 5th to 11th ribs in 34 cases after treatment of hepatic lesions; anterior arcs of 2nd to 5th ribs in 5 cases after treatment for breast tumors; and posterior arcs of left 9th to 11th ribs or thoraco lumbar vertebrae in 4 cases after treatment for pancreas tumor. Of 20 patients who had bone scans more than twice, five showed recovered uptake of the radiotracer in the involved ribs in the follow up bone scan. Of 62 bone scans in patients with a history of HIFU treatment for primary of metastatic cancer, 69% presented diffusely decreased uptake in the bone in the path of HIFU treatment.

  5. Automated segmentation of tumors on bone scans using anatomy-specific thresholding

    Science.gov (United States)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Lu, Peiyun; Ramakrishna, Bharath; Gjertson, David; Poon, Cheryce; Auerbach, Martin; Goldin, Jonathan; Brown, Matthew S.

    2012-03-01

    Quantification of overall tumor area on bone scans may be a potential biomarker for treatment response assessment and has, to date, not been investigated. Segmentation of bone metastases on bone scans is a fundamental step for this response marker. In this paper, we propose a fully automated computerized method for the segmentation of bone metastases on bone scans, taking into account characteristics of different anatomic regions. A scan is first segmented into anatomic regions via an atlas-based segmentation procedure, which involves non-rigidly registering a labeled atlas scan to the patient scan. Next, an intensity normalization method is applied to account for varying levels of radiotracer dosing levels and scan timing. Lastly, lesions are segmented via anatomic regionspecific intensity thresholding. Thresholds are chosen by receiver operating characteristic (ROC) curve analysis against manual contouring by board certified nuclear medicine physicians. A leave-one-out cross validation of our method on a set of 39 bone scans with metastases marked by 2 board-certified nuclear medicine physicians yielded a median sensitivity of 95.5%, and specificity of 93.9%. Our method was compared with a global intensity thresholding method. The results show a comparable sensitivity and significantly improved overall specificity, with a p-value of 0.0069.

  6. Camurati-Engelmann's Disease on {sup 99m}Tc-MDP Bone Scan

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai Jeon; Oh, So Won; Paeng, Jin Chul; Lee, You Kyung; Choi, In Ho; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-12-15

    A 24 year-old female presented for a {sup 99m}Tc-methylene diphosphonate (MDP) whole body bone scan due to chronic pain in the bilateral lower extremities that has aggravated since 2002. She was diagnosed with Camurati-Engelmann disease (CED) based on the clinical and radiological findings in 2002, and she re-visited our institute to evaluate disease status at this time. CED is a rare autosomal dominant type of bone dysplasia characterized by progressive cortical thickening of long bones, and narrowing of medullary cavity, and thus presents with typical clinical symptoms and signs such as chronic pain in the extremities, muscle weakness, and waddling gait. On the {sup 99m}Tc-MDP bone scan performed to evaluate disease status, intense increased uptake was seen in the skull, facial bones, bilateral scapulae, bilateral long bones, and bilateral pelvic bones, which clearly demonstrated the extent of CED involvement.

  7. Discrepancy of bone metastases between F-18 FDG PET/CT and bone scan in a patient with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Jin; Kim, Chul Soo; Byun, Sung Su; Hyun, In Young [Inha University College of Medicine, Incheon (Korea, Republic of)

    2006-10-15

    We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

  8. Bone scan: Indium-WBC correlation in the diagnosis of osteomyelitis of the foot

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B.; Wrege, S.S.; Altman, M.I.; Moore, J.W. (Veterans Administration Medical Center, Albuquerque, NM (USA))

    1989-11-01

    A retrospective study was performed of 20 podiatric cases using technetium-99m methylene diphosphonate three-phase bone scans along with indium-111 oxine leukocyte scans, as needed, to determine the presence and extent of osteomyelitis of the foot. Using criteria developed at our institution, the authors attempt to provide a mechanism to make a reliable diagnosis for osteomyelitis that has been supported by surgical/pathologic confirmation of long-term clinical follow-up. The sensitivity, using bone scans alone, was 100%, and specificity was 47%. Correlating bone and indium-111 leukocyte scans yielded a sensitivity of 100% with a specificity raised to 81%. Indium-111 leukocyte scans were used in 40% of cases when a definitive diagnosis for osteomyelitis could not be made on the basis of the three-phase bone scan or clinical presentation alone. Indium-111 leukocyte scans were also helpful in delineating the extent of the disease process. The authors present a standard technique for a 5-hour delayed imaging in the three-phase bone scan, as well as marking the foot in the indium-111 leukocyte scan with three routine views obtained for each imaging procedure, to ensure clinical accuracy.

  9. Splenic hemochromatosis incidentally found on Tc-99m MDP bone scan in a chronic myelogenous leukemia patient who received bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-02-01

    Tc-99m MDP bone scan was performed to evaluate a generalized bone pain in a 24-year-old male chronic myelogenous leukemia patient who received bone marrow transplantation at 7 months ago. The patient had received large amounts of blood transfusion for managing symptoms related to anemia. Bone scan revealed substantial splenic tracer uptake. Magnetic resonance image and laboratory evidence of hemochromatosis suggests that the presence of large quantities of iron in the spleen of this patient may have been responsible for the splenic uptake of the bone scanning agent. The authors report a c ase of splenic hemochromatosis incidentally found on Tc-99m MDP bone scan.

  10. Quality of planar whole-body bone scan interpretations - a nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Sadik, May; Suurkula, Madis [Sahlgrenska University Hospital, Department of Clinical Physiology, Goeteborg (Sweden); Hoeglund, Peter [Lund University Hospital, Competence Center for Clinical Research, Lund (Sweden); Jaerund, Andreas [EXINI Diagnostics AB, Lund (Sweden); Edenbrandt, Lars [Sahlgrenska University Hospital, Department of Clinical Physiology, Goeteborg (Sweden); Lund University Research Program in Medical Informatics, Malmoe University Hospital, Department of Clinical Sciences, Malmoe, Malmoe (Sweden)

    2008-08-15

    The purpose of this study was to investigate, in a nationwide study, the inter-observer variation and performance in interpretations of bone scans regarding the presence or absence of bone metastases. Bone scan images from 59 patients with breast or prostate cancer, who had undergone scintigraphy due to suspected bone metastatic disease, were studied. The patients were selected to reflect the spectrum of pathology found in everyday clinical work. Whole body images, anterior and posterior views, were sent to all 30 hospitals in Sweden that perform bone scans. Thirty-seven observers from 18 hospitals agreed to participate in the study. They were asked to classify each of the patient studies regarding the presence of bone metastasis, using a four-point scale. Each observer's classifications were pairwise compared with the classifications made by all the other observers, resulting in 666 pairs of comparisons. The interpretations of the 37 observers were also compared with the final clinical assessment, which was based on follow-up scans and other clinical data. On average, two observers agreed on 64% of the bone scan classifications. Kappa values ranged between 0.16 and 0.82, with a mean of 0.48. Sensitivity and specificity for the observers compared with the final clinical assessment were 77% and 96%, respectively, for detecting bone metastases in planar whole-body bone scanning. Moderate inter-observer agreement was found when observers were compared pairwise. False-negative errors seem to be the major problem in the interpretations of bone scan images, whilst the specificities for the observers were high. (orig.)

  11. When is a bone scan study appropriate in asymptomatic men diagnosed with prostate cancer?

    Institute of Scientific and Technical Information of China (English)

    Raj P.Pal; Thivyaan Thiruudaian; Masood A.Khan

    2008-01-01

    Aims: To determine when a bone scan investigation is appropriate in asymptomatic men diagnosed with prostate cancer. Methods: Between November 2005 and July 2006, 317 men with prostate cancer underwent a bone scan study; 176 men fulfilled the inclusion criteria. Prostate-specific antigen (PSA) cut-offs as well as univariate and multivariate logistic regression analyses using digital rectal examination finding, biopsy Gleason scores and age were performed to determine when a bone scan study is likely to be of value. Results: Only 1/61 men (1.6%) with a serum PSA ≤ 20 ng/mL had a positive bone scan. However, 2/38 men (4.7%) with a serum PSA 20.1-40.0 ng/mL, 3/20 men (15%) with a serum PSA 40.1-60.0 ng/mL, 7/19 men (36.8%) with a serum PSA 60.1-100.0 ng/mL and 19/38 men (50%) with a serum PSA > 100.0 ng/mL had positive bone scans. Univariate and multivariate logistic regression analyses were uninformative in these groups. Conclusion: Based on our findings, a bone scan is of limited value in asymptomatic prostate cancer patients presenting PSA ≤ 20 ng/mL. Therefore, this investigation can be eliminated unless a curative treatment is contemplated. Furthermore, digital rectal examination finding, biopsy Gleason score and age are unhelpful in predicting those who might harbor bone metastasis.

  12. Bone scanning after muscle-pedicle bone graft for femoral neck fracture, (1). Preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yutaka; Nabeshima, Kazuo; Okazaki, Takeyuki; Dogo, Akihiko; Kurihara, Makoto; Tsai, Yeong-Nan (Kawasaki Steel Corp., Kobe (Japan))

    1982-04-01

    sup(99m)Tc-MDP bone scintigraphy was performed on patients who received muscle-pedicle bone graft. In each of the bone head and the bone graft, a time-activity curve was obtained. In this muscle-pedicle bone graft, active revascularization and marked osteogenesis, which suggested rapid bone repairing, were observed. The bone scintigraphy was considered to be useful in observing the result of bone grafts, blood circulation, and time of bone fusion, and of value for early detection of secondary changes.

  13. Two unusual causes of peripatellar nonmetastatic positive bone scans in patients with malignancies: case reports.

    Science.gov (United States)

    Turner, J W; Syed, I B; Spencer, R P

    1976-08-01

    Bone scans performed with 99mTc-polyphosphate in two patients with epidermoid carcinoma of the lung each showed activity in one knee area. In the first case, radiographs of the area revealed Pellegrini-Stieda calcification over the internal femoral condyle. Uptake corresponded to this process, rather than to a lesion deep in the bone. In the second case, the activity accumulation in the right tibia was the only abnormality noted in the scan. An open biopsy revealed Paget's disease, and no radiographic evidence of Paget's disease was found in any other bone. These cases again illustrate that localized accumulation of a bone-scanning agent, in patients with known primary tumors, does not necessarily denote malignancy in bone.

  14. Two unusual causes of peripatellar nonmetastatic positive bone scans in patients with malignancies: case reports

    Energy Technology Data Exchange (ETDEWEB)

    Turner, J.W.; Syed, I.B.; Spencer, R.P.

    1976-08-01

    Bone scans performed with /sup 99m/Tc-polyphosphate in two patients with epidermoid carcinoma of the lung each showed activity in one knee area. In the first case, radiographs of the area revealed Pellegrini-Stieda calcification over the internal femoral condyle. Uptake corresponded to this process, rather than to a lesion deep in the bone. In the second case, the activity accumulation in the right tibia was the only abnormality noted in the scan. An open biopsy revealed Paget's disease, and no radiographic evidence of Paget's disease was found in any other bone. These cases again illustrate that localized accumulation of a bone-scanning agent, in patients with known primary tumors, does not necessarily denote malignancy in bone.

  15. Scanning electron microscopy analysis of experimental bone hacking trauma of the mandible.

    Science.gov (United States)

    Alunni-Perret, Véronique; Borg, Cybèle; Laugier, Jean-Pierre; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald; Muller-Bolla, Michèle

    2010-12-01

    The authors report on a macroscopic and microscopic study of human mandible bone lesions achieved by a single-blade knife and a hatchet. The aim of this work was to complete the previous data (scanning electron microscopy analysis of bone lesions made by a single-blade knife and a hatchet, on human femurs) and to compare the lesions of the femur with those of the mandible. The results indicate that the mandible is a more fragile bone, but the features observed on the mandible are quite similar to those previously observed on the femur. This work spells out the main scanning electron microscopy characteristics of sharp (bone cutting) and blunt (exerting a pressure on the bone) mechanisms on human bone. Weapon characteristics serve to explain all of these features.

  16. The Role of Gallium scanning in the detection of bone and joint sepsis

    OpenAIRE

    Gavin, Anna; Laird, J. D.; Roberts, S.D.

    1984-01-01

    The value of gallium (67Ga) scanning in the diagnosis of septic disease of bone or joint was assessed in 34 patients. The results show a sensitivity of 60 per cent and specificity of 64 per cent. The low accuracy of this method for the detection of bone and joint sepsis (62 per cent) means that gallium scanning can be used only as an adjunct to other investigative techniques.

  17. Thalassemia paravertebral tumors and bone marrow scan; Thalassemies, tumeurs paravertebrales et scintigraphie medullaire

    Energy Technology Data Exchange (ETDEWEB)

    Huglo, D.; Rose, C.; Deveaux, M.; Bauters, F.; Marchandise, X. [Centre Hospitalier Universitaire, 59 - Lille (France)

    1995-12-01

    Two first cousins with thalassemia and with a paravertebral mass had had an indium 111 chloride bone marrow scan. Result of scan influenced therapy: medical treatment in one case where an extramedullary erythropoiesis was confirmed, surgical treatment in the other case. The use of dual-isotope SPECT (indium 111 chloride, HDP{sup -99}Tc) constitutes a contribution to the establishment of diagnosis of extramedullary erythropoiesis, giving to bone marrow scintigraphy a merited importance, avoiding the biopsy. (authors). 15 refs., 5 figs.

  18. Scanning electron microscopy analysis of experimental bone hacking trauma.

    Science.gov (United States)

    Alunni-Perret, Veronique; Muller-Bolla, Michèle; Laugier, Jean-Pierre; Lupi-Pégurier, Laurence; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald

    2005-07-01

    The authors report on their macro- and microscopy study of bone lesions made by a sharp force instrument (a single blade knife), and a sharp-blunt instrument classified as a chopping weapon (a hatchet). The aim of this work was to attempt to identify the instrument by analyzing the general class characteristics of the cuts. Each weapon was used on human bones. The results indicate that macroscopic analysis is more problematic. The microscopic analysis assessed that characteristics examined were effective in distinguishing sharp from sharp-blunt injury to the bone. The microscope facilitates analysis unachievable with macroscopic methods, some three-dimensional characteristics not visible to the naked eye being clearly defined with its use. Emphasis has been placed on the value of SEM as an anthropologist's tool in bone lesion injuries.

  19. Reversible bone pain and symmetric bone scan uptake in a dialysis patient treated with cinacalcet: a case report

    Directory of Open Access Journals (Sweden)

    Bottino Carla

    2010-06-01

    Full Text Available Abstract Introduction The medical management of secondary hyperparathyroidism in patients with end-stage renal disease involves a combination of dietary restrictions, phosphate binders, active vitamin D analogs, and calcimimetics. Case presentation We report the case of a 36-year-old Hispanic dialysis patient, originally from Cuba and now residing in the USA, who developed severe bone pain and muscle twitching after starting low dose cinacalcet, despite normal pre-dialysis ionized calcium and elevated parathyroid hormone. The clinical symptoms correlated with increased symmetrical uptake on bone scan that resolved rapidly upon discontinuation of cinacalcet. Conclusion Cinacalcet may induce severe bone pain and a unique bone scan uptake pattern in hemodialysis patients.

  20. Reversible bone pain and symmetric bone scan uptake in a dialysis patient treated with cinacalcet: a case report

    Science.gov (United States)

    2010-01-01

    Introduction The medical management of secondary hyperparathyroidism in patients with end-stage renal disease involves a combination of dietary restrictions, phosphate binders, active vitamin D analogs, and calcimimetics. Case presentation We report the case of a 36-year-old Hispanic dialysis patient, originally from Cuba and now residing in the USA, who developed severe bone pain and muscle twitching after starting low dose cinacalcet, despite normal pre-dialysis ionized calcium and elevated parathyroid hormone. The clinical symptoms correlated with increased symmetrical uptake on bone scan that resolved rapidly upon discontinuation of cinacalcet. Conclusion Cinacalcet may induce severe bone pain and a unique bone scan uptake pattern in hemodialysis patients. PMID:20576153

  1. Improving radionuclide therapy in prostate cancer patients with metastatic bone pain

    NARCIS (Netherlands)

    Lam, M.G.E.H.

    2009-01-01

    Bone seeking radiopharmaceuticals are indicated in cancer patients with multiple painful skeletal metastases. The majority of these patients are hormone-refractory prostate cancer patients in an advanced stage of their disease. Bone seeking radiopharmaceuticals relieve pain and improve the patients

  2. Comparison of bone scan with carbohydrate antigen 15-3 for evaluation of bone metastasis of brest cancer.

    Science.gov (United States)

    Mohammadzadeh, M; Alikhah, H; Zareh, A G A

    2010-02-15

    This study aimed at comparing the bone scan and CA15-3 titer in patients with breast cancer for evaluation of bone metastasis. Thirty five patients with definite diagnosis of breast cancer were evaluated in Tabriz Imam Khomeini Hospital from 2007 to 2008. Bone scan (99 mTc-MDP) performed in all patients. The serum CA15-3 was measured by ECLIA method. The increased level was considered as >30 U mL(-1). The serum level of CA15-3 was compared between the patients with and without bone metastasis, as well as its correlation with the extent of bone involvement. Thirty five patients with the mean age of 51.69 +/- 10.77 (34-81) years were enrolled in the study. According to bone scan results, 24 (68.8%) patients revealed bone metastasis. The mean level of serum CA15-3 was significantly higher in patents with bone metastasis than patients without metastasis (26.37 +/- 4.74 U mL(-1) vs. 19.09 +/- 1.99 U mL(-1); p 21.8 U mL(-1) for the serum level of CA15-3 in our patients, with a sensitivity and specificity of 91.7 and 91%, respectively. Serum level of CA15-3 is higher in the patients with bone metastatic breast cancer; however, the recommended cut-off point might not be suitable for Iranian patients. Further studies with large sample sizes are recommended.

  3. Gallbladder radionuclide scan

    Science.gov (United States)

    ... ducts Cancer of the hepatobiliary system Gallbladder infection ( cholecystitis ) Gallstones Infection of the gallbladder, ducts, or liver ... Saunders; 2010:chap 65. Read More Acute Acute cholecystitis Bile Bile duct obstruction Cyst Gallstones Liver cancer - ...

  4. The bone scan in tarsal coalition: a case report

    Energy Technology Data Exchange (ETDEWEB)

    De Lima, R.T. [Department of Radiology, Division of Nuclear Medicine, Harbor-UCLA Medical Center, Torrance, CA (United States); Mishkin, F.S. [Department of Radiology, Division of Nuclear Medicine, Harbor-UCLA Medical Center, Torrance, CA (United States)

    1996-10-01

    Tarsal coalition is abnormal fusion of two or more tarsal bones. The union may be fibrous, cartilaginous, or osseous and can be congenital or acquired in response to infection, articular disorders, trauma, or surgery. We report a case of fibrous talocalcaneal coalition in a 15-year-old boy in whom bone scintigraphy employing pinhole lateral views confirmed the clinical diagnosis when plain radiographs showed minimal changes and computed tomography was equivocal. The diagnosis of symptomatic tarsal coalition is important in that it is a common remediable cause of peroneal spastic flat foot, a frequently encountered condition. Scintigraphy provides important information about the presence and localization of this condition. (orig.). With 3 figs.

  5. Is there a role of whole-body bone scan in patients with esophageal squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Li Shau-Hsuan

    2012-08-01

    Full Text Available Abstract Background Correct detection of bone metastases in patients with esophageal squamous cell carcinoma is pivotal for prognosis and selection of an appropriate treatment regimen. Whole-body bone scan for staging is not routinely recommended in patients with esophageal squamous cell carcinoma. The aim of this study was to investigate the role of bone scan in detecting bone metastases in patients with esophageal squamous cell carcinoma. Methods We retrospectively evaluated the radiographic and scintigraphic images of 360 esophageal squamous cell carcinoma patients between 1999 and 2008. Of these 360 patients, 288 patients received bone scan during pretreatment staging, and sensitivity, specificity, positive predictive value, and negative predictive value of bone scan were determined. Of these 360 patients, surgery was performed in 161 patients including 119 patients with preoperative bone scan and 42 patients without preoperative bone scan. Among these 161 patients receiving surgery, 133 patients had stages II + III disease, including 99 patients with preoperative bone scan and 34 patients without preoperative bone scan. Bone recurrence-free survival and overall survival were compared in all 161 patients and 133 stages II + III patients, respectively. Results The diagnostic performance for bone metastasis was as follows: sensitivity, 80%; specificity, 90.1%; positive predictive value, 43.5%; and negative predictive value, 97.9%. In all 161 patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence-free survival (P = 0.009, univariately. In multivariate comparison, absence of preoperative bone scan (P = 0.012, odds ratio: 5.053 represented the independent adverse prognosticator for bone recurrence-free survival. In 133 stages II + III patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence

  6. Evaluation of bone-marrow scanning with technetium-99m sulfur colloid in pediatric oncology.

    Science.gov (United States)

    Siddiqui, A R; Oseas, R S; Wellman, H N; Doerr, D R; Baehner, R L

    1979-05-01

    Eighty-six technetium-99m sulfur colloid (Tc-SC) bone-marrow scans in 56 pediatric oncology patients were reviewed. The distribution of the sulfur colloid was similar to that in adult bone marrow in normal children older than 10 yr, and involved progressively more marrow of the extremities in normal children under 10 years of age. After irradiation or chemotherapy there was an extension of the Tc-SC to peripheral marrow sites. There was also diminished uptake of the tracer in sites corresponding to irradiated areas. In most patients there was recovery of these defects by 6 mo after completion of therapy. Tumor replacement of the marrow was reflected in the scans, and the extent of the scan defect paralleled the course of the disease. In four patients, despite normal bone scans and radiographs, marrow-scan abnormalities due to tumor replacement were present and confirmed by needle aspiration and/or biopsy. In two other patients, the marrow-scan abnormality preceded radiographic and histologic evidence of tumor metastasis. Two patients who responded clinically showed persistent defects; biopsy in one revealed fibrosis. Technetium-99m sulfur colloid bone-marrow scanning appears to be a sensitive monitor of marrow alteration caused by metastases, irradiation damage, or tissue fibrosis in children receiving treatment for cancer.

  7. Normal SUV values measured from NaF18- PET/CT bone scan studies.

    Directory of Open Access Journals (Sweden)

    Aung Zaw Win

    Full Text Available Cancer and metabolic bone diseases can alter the SUV. SUV values have never been measured from healthy skeletons in NaF18-PET/CT bone scans. The primary aim of this study was to measure the SUV values from normal skeletons in NaF18-PET/CT bone scans.A retrospective study was carried out involving NaF18- PET/CT bone scans that were done at our institution between January 2010 to May 2012. Our excluding criteria was patients with abnormal real function and patients with past history of cancer and metabolic bone diseases including but not limited to osteoporosis, osteopenia and Paget's disease. Eleven studies met all the criteria.The average normal SUVmax values from 11 patients were: cervical vertebrae 6.84 (range 4.38-8.64, thoracic vertebrae 7.36 (range 6.99-7.66, lumbar vertebrae 7.27 (range 7.04-7.72, femoral head 2.22 (range 1.1-4.3, humeral head 1.82 (range 1.2-2.9, mid sternum 5.51 (range 2.6-8.1, parietal bone 1.71 (range 1.3-2.4.According to our study, various skeletal sites have different normal SUV values. SUV values can be different between the normal bones and bones with tumor or metabolic bone disease. SUV can be used to quantify NaF-18 PET/CT studies. If the SUV values of the normal skeleton are known, they can be used in the characterization of bone lesions and in the assessment of treatment response to bone diseases.

  8. Improving radionuclide therapy in prostate cancer patients with metastatic bone pain

    OpenAIRE

    2009-01-01

    Bone seeking radiopharmaceuticals are indicated in cancer patients with multiple painful skeletal metastases. The majority of these patients are hormone-refractory prostate cancer patients in an advanced stage of their disease. Bone seeking radiopharmaceuticals relieve pain and improve the patients quality of life. The mostly used radiopharmaceuticals are 89SrCl2 (Metastron), 153Sm-EDTMP (Quadramet) and 186Re-HEDP. Differences between 89SrCl2, 153Sm-EDTMP and 186Re-HEDP were investigated. It ...

  9. Enhanced diagnostic accuracy for quantitative bone scan using an artificial neural network system: a Japanese multi-center database project

    National Research Council Canada - National Science Library

    Nakajima, Kenichi; Nakajima, Yasuo; Horikoshi, Hiroyuki; Ueno, Munehisa; Wakabayashi, Hiroshi; Shiga, Tohru; Yoshimura, Mana; Ohtake, Eiji; Sugawara, Yoshifumi; Matsuyama, Hideyasu; Edenbrandt, Lars

    2013-01-01

    Artificial neural network (ANN)-based bone scan index (BSI), a marker of the amount of bone metastasis, has been shown to enhance diagnostic accuracy and reproducibility but is potentially affected by training database...

  10. Is there a role of whole-body bone scan in patients with esophageal squamous cell carcinoma

    OpenAIRE

    Li Shau-Hsuan; Huang Yung-Cheng; Huang Wan-Ting; Lin Wei-Che; Liu Chien-Ting; Tien Wan-Yu; Lu Hung-I

    2012-01-01

    Abstract Background Correct detection of bone metastases in patients with esophageal squamous cell carcinoma is pivotal for prognosis and selection of an appropriate treatment regimen. Whole-body bone scan for staging is not routinely recommended in patients with esophageal squamous cell carcinoma. The aim of this study was to investigate the role of bone scan in detecting bone metastases in patients with esophageal squamous cell carcinoma. Methods We retrospectively evaluated the radiographi...

  11. Observation of 99mTc-MDP-bone scan findings in traumatic vertebral fractures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Soon Im; Kim, Pyo Nyun; Lee, Hae Kyung; Chung, Moo Chan; Choi, Deuk Lin; Kim, Ki Jung [Soon Chun Hyang University Hospital, Seoul (Korea, Republic of)

    1984-03-15

    Bone scan using 99mTc-MDP is the most accurate and reliable method for the early detection of fracture, and give the most accurate information about the healing process of fractured bone. Recent days, the medicolegal problem about the injured time is frequently provoked in vertebral fracture patient by trauma. The authors analyzed the bone scan of vertebral fracture patients from March to December, 1983. The Authors obtained results as follows: 1. The minimum time for a fracture to return to normal on a bone scan was 4 month in cervical spine. 2. It was 12 month in thoracic spine. 3. It was 6 month in lumbar spine. 4. Surrounding soft tissue injury was healed within 10 days after trauma in our cases. 5. Focal hot uptake is persisted in case of callus deposition on plain film, although very small in amount. 6. Healing time is delayed in case of severely compressed vertebral body, belowed the half than normal height. 7. With bone scan, it is possible to differentiate the fresh fracture from old healed fracture, impossible by plain film. 8. Healing time is delayed in old age.

  12. Bone scan findings in calcific tendinitis at the gluteus maximus insertion: some illustrative cases

    Directory of Open Access Journals (Sweden)

    Karel Van Damme

    2017-03-01

    Full Text Available We describe the bone scan and single-photon emission computed tomography/computed tomography findings in calcific tendinitis of the gluteus maximus and discuss its pathophysiology. Although this tendinopathy is mostly self-limiting, awareness of this disease is important for 2 reasons. First, it may explain acute hip symptoms in patients in the resorptive phase of the calcifications. Second, it should be considered as a differential diagnosis for bone scan hot spots in the vicinity of the gluteus maximus tendon and for cortical erosion seen in that region on X-rays or CT.

  13. Correlative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections

    Science.gov (United States)

    Giannini, C.; Siliqi, D.; Bunk, O.; Beraudi, A.; Ladisa, M.; Altamura, D.; Stea, S.; Baruffaldi, F.

    2012-01-01

    Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon resolution. This favorable combination has been applied for the first time to biopsies of dwarfism syndrome and Paget's disease to shed light onto the cortical structure of natural bone in healthy and pathologic sections. PMID:22666538

  14. CT-scanning of the temporal bone in an inner ear malformation

    Energy Technology Data Exchange (ETDEWEB)

    Murata, K.; Hosoi, H.; Isono, M.; Ohta, F. (Kinki Univ., Higashi-Osaka, Osaka (Japan))

    1982-05-01

    CT-scanning of the temporal bone revealed a fine contour of the inner ear anomaly in a 8-year-old boy with total deafness on the right. In the inner ear there was a globular mass with a small protrusion anteriorly and with a probably immature superior semi-circular canal. The globular mass was considered to be the utriculosaccular capsule, and the anterior protrusion to be an incipient cochlear duct. CT-scanning of the temporal bone may bring significant progress in diagnosis of inner ear anomalies. Detailed configuration of an inner ear may be shown before histological examination.

  15. The Utilization of Gleason Grade as the Primary Criterion for Ordering Nuclear Bone Scan in Newly Diagnosed Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Chad W. M. Ritenour

    2009-01-01

    Full Text Available Utilization of nuclear bone scans for staging newly diagnosed prostate cancer has decreased dramatically due to PSA-driven stage migration. The current criteria for performing bone scans are based on limited historical data. This study evaluates serum PSA and Gleason grade in predicting positive scans in a contemporary large series of newly diagnosed prostate cancer patients. Eight hundred consecutive cases of newly diagnosed prostate cancer over a 64-month period underwent a staging nuclear scan. All subjects had histologically confirmed cancer. The relationship between PSA, Gleason grade, and bone scan was examined by calculating series of crude, stratified, and adjusted odds ratios with corresponding 95% confidence intervals. Four percent (32/800 of all bone scans were positive. This proportion was significantly lower in patients with Gleason score ≤7 (1.9% vs. Gleason score ≥8 (18.8%, p 30 ng/ml compared to ≤30 ng/ml (p 10 ng/ml compared to ≤10 ng/ml (p = 0.002. The combination of Gleason score and PSA enhances predictability of bone scans in newly diagnosed prostate cancer patients. The PSA threshold for ordering bone scans should be adjusted according to Gleason score. For patients with Gleason scores ≤7, we recommend a bone scan if the PSA is >30 ng/ml. However, for patients with a high Gleason score (8–10, we recommend a bone scan if the PSA is >10 ng/ml.

  16. Incidental Visualization of Thyroid Gland on Bone Scan Caused by Graves' Hyperthyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Kim, Dong Wook; Lim, Seok Tae [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-04-15

    A 45-year-old man presented with fatigue and weight loss underwent a Tc-99m MDP bone scan because of increased serum alkaline phosphatase. Delayed images at 4 hours demonstrated diffuse increased activity throughout both lobes of the thyroid in the absence of activity of the stomach and salivary glands. Thyroid laboratory indices and a Tc-99m pertechnetate thyroid scan suggested Graves' hyperthyroidism

  17. Correlative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections

    OpenAIRE

    Giannini, C.; D. Siliqi; Bunk, O.; Beraudi, A.; Ladisa, M.; Altamura, D.; Stea, S.; Baruffaldi, F.

    2012-01-01

    Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon res...

  18. Radionuclides in deer and elk from Los Alamos National Laboratory and the doses to humans from the ingestion of muscle and bone.

    Science.gov (United States)

    Fresquez, P R; Biggs, J R; Bennett, K D; Kraig, D H; Mullen, M A; Ferenbaugh, J K

    1999-09-01

    This paper summarizes radionuclide concentrations (3H, 90Sr, 137Cs, 238Pu, 239,240Pu, 241Am, and totU) in muscle and bone tissue of mule deer (Odocoileus hemionus) and Rocky Mountain elk (Cervus elaphus) collected from Los Alamos National Laboratory (LANL), Los Alamos, New Mexico, lands from 1991 through 1998. Also, the committed effective dose equivalent (CEDE) and the risk of excess cancer fatalities (RECF) to people who ingest muscle and bone from deer and elk collected from LANL lands were estimated. Most radionuclide concentrations in muscle and bone from individual deer (n = 11) and elk (n = 22) collected from LANL lands were either at less than detectable quantities (where the analytical result was smaller than two counting uncertainties) and/or within upper (95%) level background (BG) concentrations. As a group, most radionuclides in muscle and bone of deer and elk from LANL lands were not significantly higher (p < 0.10) than in similar tissues from deer (n = 3) and elk (n = 7) collected from BG locations. Also, elk that had been radio collared and tracked for two years and spent an average time of 50% of LANL lands were not significantly different in most radionuclides from road kill elk that have been collected as part of the environmental surveillance program. Overall, the upper (95%) level net CEDEs (the CEDE plus two sigma for each radioisotope minus background) at the most conservative ingestion rate (50 lbs of muscle and 13 lbs of bone) were as follows: deer muscle = 0.22 mrem y-1 (2.2 microSv y-1), deer bone = 3.8 mrem y-1 (38 microSv y-1), elk muscle = 0.12 mrem y-1 (1.2 microSv y-1), and elk bone = 1.7 mrem y-1 (17 microSv y-1). All CEDEs were far below the International Commission on Radiological Protection guideline of 100 mrem y-1 (1000 microSv y-1), and the highest muscle plus bone net CEDE corresponded to a RECF of 2E-06, which is far below the Environmental Protection Agency upper level guideline of 1E-04.

  19. Role of technetium-99m planar bone scanning in the evaluation of low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Valdez, D.C. [Texas Univ., San Antonio, TX (United States). Health Science Center]|[St. Luke`s Lutheran Hospital, San Antonio, TX (United States); Johnson, R.G. [Texas Univ., San Antonio, TX (United States). Health Science Center]|[St. Luke`s Lutheran Hospital, San Antonio, TX (United States)

    1994-02-01

    The records of 1018 patients with low back pain in a tertiary spine referral practice were reviewed. One hundred thirty-nine out of 1018 (13.6%) underwent technetium-99m planar bone scannings as part of their investigation. Seventy-three out of 139 scans (52%) showed increased uptake in some area, but only 27 out of 139 (19.4%) showed increased uptake specifically in the low back. Scans consistently yielded no findings with reference to the back when the prescan diagnosis was spinal stenosis, lumbar pain syndrome, herniated nucleus pulposus, or postlaminectomy syndrome. Some scans gave positive findings in patients with a diagnosis of degenerative disc disease, pseudoarthrosis, spondylolisthesis, fracture, infection, metabolic disorder, or tumor. Positive scans were generally obtained early after presentation (within 3 months) and negative scans obtained later (after 6 months), suggesting that clinical suspicion is still the main indication for early scanning. Planar bone scanning was helpful in both diagnosis and therapeutic decision-making in many conditions. (orig.)

  20. Comparison of gated radionuclide scans and chest radiographs. Assessment of left ventricular impairment in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Reinke, D B; Makey, D G; Shafer, R B

    1980-03-01

    Diagnostic efficacy of gated cardiac blood pool imaging was studied in 41 consecutive patients with LV ejection fractions (LVEF) less than or equal to 0.50. Eighty percent of patients were receiving therapy for LV failure at the time of the study. All patients had documented coronary-artery disease (CAD). Chest x-ray films were interpreted blindly by a senior radiologist. Cardiothoracic ratio of less than or equal to 0.50 was recorded as normal. Radionuclide assessment of LV function contributes importantly to the diagnostic and screening value of chest x-ray films. Patients with coronary disease and clinical evidence of heart failure should have radioisotopic studies even if chest x-ray film findings are normal. In patients with coronary artery disease and enlarged LV on chest films, radionuclide study of left ventricular performance aids in defining LV impairment, and in the prognostication of subsequent clinical course.

  1. Study of fossil bones by synchrotron radiation micro-spectroscopic techniques and scanning electron microscopy.

    Science.gov (United States)

    Zougrou, I M; Katsikini, M; Pinakidou, F; Paloura, E C; Papadopoulou, L; Tsoukala, E

    2014-01-01

    Earlymost Villafranchian fossil bones of an artiodactyl and a perissodactyl from the Milia excavation site in Grevena, Greece, were studied in order to evaluate diagenetic effects. Optical microscopy revealed the different bone types (fibro-lamellar and Haversian, respectively) of the two fragments and their good preservation state. The spatial distribution of bone apatite and soil-originating elements was studied using micro-X-ray fluorescence (µ-XRF) mapping and scanning electron microscopy. The approximate value of the Ca/P ratio was 2.2, as determined from scanning electron microscopy measurements. Bacterial boring was detected close to the periosteal region and Fe bearing oxides were found to fill bone cavities, e.g. Haversian canals and osteocyte lacunae. In the perissodactyl bone considerable amounts of Mn were detected close to cracks (the Mn/Fe weight ratio takes values up to 3.5). Goethite and pyrite were detected in both samples by means of metallographic microscopy. The local Ca/P ratio determined with µ-XRF varied significantly in metal-poor spots indicating spatial inhomogeneities in the ionic substitutions. XRF line scans that span the bone cross sections revealed that Fe and Mn contaminate the bones from both the periosteum and medullar cavity and aggregate around local maxima. The formation of goethite, irrespective of the local Fe concentration, was verified by the Fe K-edge X-ray absorption fine structure (XAFS) spectra. Finally, Sr K-edge extended XAFS (EXAFS) revealed that Sr substitutes for Ca in bone apatite without obvious preference to the Ca1 or Ca2 unit-cell site occupation.

  2. Risk of metastasis among rib abnormalities on bone scans in breast cancer patients

    Science.gov (United States)

    Li, Qin; Chen, Zhiqiang; Zhao, Yansheng; Li, Xiuqing; Pan, Hong; Xia, Tiansong; Chen, Lin; Xu, Zhaoqiang; Zhou, Wenbin; Liu, Xiaoan

    2015-01-01

    Bone scan abnormalities, especially rib lesions, are often confusing for physicians due to a high number of false-positive lesions. This study investigated risk factors that are associated with bone metastasis in 613 breast cancer patients with bone scan abnormalities. Significantly increased rates of bone metastasis were observed in patients with multiple lesions, large tumor sizes, and lymph node involvement. In addition, patients with concurrent lesions of rib and other sites exhibited a significant higher rate of metastatic disease compared to those with other site lesions (P = 0.009). In the subset of 324 patients with rib abnormalities, the rate of metastasis was extremely low in patients with pure rib lesions (1.2%; 95% CI: 0.1%–4.1%). Concurrent lesions of rib and other sites were more likely to be rib metastasis compared to pure rib lesions (P rib lesions and lesions located on bilateral ribs were more likely to be rib metastasis (P rib abnormalities could be recommended for follow-up only. However, if concurrent lesions of rib and other sites were detected on bone scans, additional radiological examinations should be performed to patients. PMID:25939860

  3. Transmission and scanning electron microscopy confirm that bone microstructure is similar in osteopenic and osteoporotic patients.

    Science.gov (United States)

    Gül, Orkun; Atik, O Sahap; Erdoğan, Deniz; Göktaş, Güleser; Elmas, Ciğdem

    2013-01-01

    The objective was to confirm the finding of "Bone microstructure is similar in osteopenic and osteoporotic patients with femoral neck fracture." obtained in previous "light microscopy study", which was new and important data. Fourteen patients (5 males, 9 females) who were admitted with proximal femoral fracture following low energy trauma (patients who participated in the light microscopy study) were included. The patients were divided into two groups based on the bone mineral density (BMD) measurement, including osteopenic group (n=7, mean age 69 years; range 63 to 74 years) and osteoporotic group (n=7, mean age 74.1 years; range 67 to 78 years). Cortical and trabecular bone samples were taken from the patients who underwent endoprosthesis during partial hip arthroplasty and these samples were analyzed using transmission electron microscopy and scanning electron microscopy evaluations which are more sophisticated higher resolution techniques. The mean cortical bone thickness was 3622.14 mm in osteopenic group and 2323.14 mm in osteoporotic group (pelectron microscopy and scanning electron microscopy evaluations revealed similar findings for both groups. Although a significant difference in cortical thickness was found between the groups, transmission and scanning electron microscopy confirmed that bone microstructure shared similar characteristics in osteopenic and osteoporotic patients with low-energy femoral neck fracture, as it was in previous light microscopy study.

  4. Photon-deficient bone scan lesion as a precursor of active Paget's disease

    Energy Technology Data Exchange (ETDEWEB)

    Jaspers, M.M.J.R.; Pauwels, E.K.J.; Blom, J. (Department of Diagnostic Radiology, Division of Nuclear Medicine, University Hospital Leiden (Netherlands)); Harinck, H.I.J. (Clinical Investigation Unit, Department of Endocrinology, University Hospital Leiden, Netherands)

    1984-05-15

    A case is presented in which a Pagetoid lesion was demonstrated as a photon-deficient area (cold spot) on the bone scan. This area changed into a hot spot 3 years after its discovery. Clinical and radiological observations provide evidence that a scintigraphically photon-deficient area may represent a precursor of active Paget's disease.

  5. Prediction of Splint Therapy Efficacy Using Bone Scan in Patients with Unilateral Temporomandibular Disorder

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Mi; Lee, Won Woo; Yun, Pil Young; Kim, Young Kyun; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul (Korea, Republic of)

    2009-04-15

    It is not known whether bone scan is useful for the prediction of the prognosis of patients with temporomandibular disorders (TMD). The aim of the present study was to identify useful prognostic markers on bone scan for the pre-therapeutic assessment of patients with unilateral TMD. Between January 2005 and July 2007, 55 patients (M:F=9:46; mean age, 34.7{+-}14.1 y) with unilateral TMD that underwent a pre-therapeutic bone scan were enrolled. Uptake of Tc-99m HDP in each temporomandibular joint (TMJ) was quantitated using a 13X13 pixel-square region-of-interest over TMJ and parietal skull area as background. TMJ uptake ratios and asymmetric indices were calculated. TMD patients were classified as improved or not improved and the bone scan findings associated with each group were investigated. Forty-six patients were improved, whereas 9 patients were not improved. There was no significant difference between the two groups of patients regarding the TMJ uptake ratio of the involved joint, the TMJ uptake ratio of the non-involved joint, and the asymmetric index (p>0.05). However, in a subgroup analysis, the patients with an increased uptake of Tc-99m HDP at the disease-involved TMJ, by visual assessment, could be easily identified by the asymmetric index; the patients that improved had a higher asymmetric index than the patients that did not improve (1.32{+-}0.35 vs. 1.08{+-}0.04, p=0.023), The Tc-99m HDP bone scan may help predict the prognosis of patients with unilateral TMD after splint therapy when the TMD-involved joint reveals increased uptake by visual assessment.

  6. Radionuclide therapy of patients with metastastic bone pain%放射性核素治疗癌转移性骨痛

    Institute of Scientific and Technical Information of China (English)

    程爱萍; 陈绍亮

    2008-01-01

    癌性骨转移原发病灶常见于前列腺癌、乳腺癌、肺癌等,转移发生的病理生理机制、疼痛机制目前不十分明确.止痛治疗尤其是对广泛骨转移性疼痛的治疗是临床医师面对的主要挑战,放射性核素及其标记药物治疗是一种有效、价廉、不良反应较小的治疗方法,对广泛转移的止痛治疗及微转移患者的治疗独具优势,目前有待充分利用.%Bone metastases are often the first sign of distant spread in breast, prostate, and lung cancers. The pathophysiology of bone metastasis is poorly understood and related complications is complex.Bone pain consequent to metastatic cancer continues to be a major therapeutic challenge for clinicians and its alleviation is crucial to improving the patient's quality of life. Targeted radionuclide therapy is an effective and cost efficient treatment for multi-site metastatic bone pain, its advantages may also include therapy for subclinical micro-or oligometastatic disease before clinical manifestation. But radionuclides remain underutilized in such treatments.

  7. Positive (/sup 99m/Tc) diphosphonate and /sup 67/Ga--citrate scans in ameloblastoma: case report

    Energy Technology Data Exchange (ETDEWEB)

    Olson, W.H.; McCombs, R.K.

    1977-04-01

    Technetium-99m-diphosphonate scintigrams and /sup 67/Ga citrate bone scans were performed in a patient with known ameloblastoma of the right mandible. The tumor concentrated both radionuclides avidly. The lesion was larger on the gallium scans, presumably due to inflammation of adjacent soft tissue and to poorer instrument resolution for /sup 67/Ga than for technetium. If a single radionuclide is to be selected for evaluating the extent of tumor in ameloblastoma, the bone-imaging agent is preferable.

  8. Current role of bone scan with phosphonates in the follow-up of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Maffioli, Lorenzo; Florimonte, Luigia; Pagani, Luca; Butti, Ivana [Division of Nuclear Medicine, Ospedale ' ' A. Manzoni' ' , Via dell' Eremo 9/11, 23900, Lecco (Italy); Roca, Isabel [Division of Nuclear Medicine, Hospital Universitari Vall Hebron, 08035, Barcelona (Spain)

    2004-06-01

    A number of studies have demonstrated that bone scintigraphy has high sensitivity and efficacy in the early detection of bone metastases from several tumours, including breast cancer. Bone scintigraphy is the most definitive tool for diagnosing and monitoring metastatic spread of breast cancer. However, in the past decade there has been a wide debate on its impact on survival time, morbidity and quality of life. Worldwide economic restrictions and these studies have led to the adoption of an almost minimalist policy for breast cancer follow-up using evidence-based guidelines. The recommended breast cancer surveillance testing includes only a few procedures (history, physical and breast self-examination, patient education on symptoms, pelvic examination). The routine use of additional tests, such as blood cell count, tumour markers, liver ultrasonography, bone scan and chest X-rays, is not recommended. Accordingly, scintigraphy should be reserved for a limited number of patients. On the other hand, early diagnosis of bone involvement may reduce the risk of skeletal related events, thus leading to a significant improvement in quality of life. Furthermore, new drugs (e.g. bisphosphonates) can now delay the onset of bone metastasis and reduce the number of patients who experience skeletal complications. In conclusion, the evidence of the clinical usefulness of bone scintigraphy (to allow early planning of new treatments in advanced disease) has to be re-evaluated, possibly by large randomised prospective trials. (orig.)

  9. Bone scan and joint scan of hands and feet in rheumatoid arthritis; Scintigraphie osseuse et articulaire des mains et des pieds dans la polyarthrite rhumatoide

    Energy Technology Data Exchange (ETDEWEB)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F. [Centre Hospitalier Universitaire Dupuytren, Faculte de Medecine, 87 - Limoges (France)

    2000-09-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate {sup 99m}Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T{sub t}) and 3 hours 1/4 (bone time, T{sub 0}) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of {sup 99m}Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T{sub 0}. The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  10. Bone marrow dosimetry in peptide receptor radionuclide therapy with [{sup 177}Lu-DOTA{sup 0},Tyr{sup 3}]octreotate

    Energy Technology Data Exchange (ETDEWEB)

    Forrer, Flavio; Krenning, Eric P.; Kooij, Peter P.; Bernard, Bert F.; Bakker, Willem H.; Teunissen, Jaap J.M.; Jong, Marion de; Kwekkeboom, Dik J. [Erasmus MC Rotterdam, Department of Nuclear Medicine, Rotterdam (Netherlands); Konijnenberg, Mark [Mallinckrodt Medical BV, Research and Development, Petten (Netherlands); Lom, Kirsten van [Erasmus MC Rotterdam, Department of Haematology, Rotterdam (Netherlands); Herder, Wouter W. de [Erasmus MC Rotterdam, Department of Internal Medicine, Rotterdam (Netherlands)

    2009-07-15

    Adequate dosimetry is mandatory for effective and safe peptide receptor radionuclide therapy (PRRT). Besides the kidneys, the bone marrow is a potentially dose-limiting organ. The radiation dose to the bone marrow is usually calculated according to the MIRD scheme, where the accumulated activity in the bone marrow is calculated from the accumulated radioactivity of the radiopharmaceutical in the blood. This may underestimate the absorbed dose since stem cells express somatostatin receptors. We verified the blood-based method by comparing the activity in the blood with the radioactivity in bone marrow aspirates. Also, we evaluated the absorbed cross-dose from the source organs (liver, spleen, kidneys and blood), tumours and the so-called ''remainder of the body'' to the bone marrow. Bone marrow aspirates were drawn in 15 patients after treatment with [{sup 177}Lu-DOTA{sup 0},Tyr{sup 3}]octreotate. Radioactivity in the bone marrow was compared with radioactivity in the blood drawn simultaneously. The nucleated cell fraction was isolated from the bone marrow aspirate and radioactivity was measured. The absorbed dose to the bone marrow was calculated. The results were correlated to the change in platelet counts 6 weeks after treatment. A strong linear correlation and high agreement between the measured radioactivities in the bone marrow aspirates and in the blood was found (r=0.914, p<0.001). No correlation between the calculated absorbed dose in the bone marrow and the change in platelets was found. There was a considerable contribution from other organs and the remainder of the body to the bone marrow absorbed dose. (1) After PRRT with [{sup 177}Lu-DOTA{sup 0},Tyr{sup 3}]octreotate, the radioactivity concentration in the bone marrow is identical to that in the blood; (2) There is no significant binding of the radiopharmaceutical to bone marrow precursor stem cells; (3) The contribution of the cross dose from source organs and tumours to the bone

  11. Clinical Utility of bone Scan in the Diagnosis of Temporomandibular disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joo; Kang, Yang Ho; Son, Seok Man; Lee, Kyoung Seog; Lee, Jae Bok; Kim, Yong Ki; Seo, Bong Jik; Park, June Sang; Park, June Sang; Ko, Myung Yun [Pusan National University College of Medicine, Pusan (Korea, Republic of); Son, Seong Pyo [Saint Benedict Hospital, Pusan (Korea, Republic of)

    1995-09-15

    Bone scan is a very sensitive diagnostic imaging test for detecting bone and joint disorders. So it might be useful in the diagnosis of temporomandibular disorders of the joint origin. Thus, the effectiveness of bone scan for detecting temporomandibular joint(TMJ) diseases and differentiating the TMJ disc displacement from the TMJ arthritis was evaluated. Bone scan was done in 21 patients with TMJ disc displacement (I3 unilaterally affected, 8 bilaterally affected), 26 patients with TMJ arthritis (23 unilateral, 3 bilateral), and 39 volunteers with no signs, symptoms, or history of TMJ disease TMJ simple uptake rate(SUR) and difference of both TMJ SUR were calculated from the 100,000 count lateral image of head and neck region in {sup 99m}Tc MDP bone scan. Transcranial and panorama X-ray examination was also done in all patients. TMJ SUR(%) were 1.67 +-0.606 in TMJs affected with arthritis, 1.350+-0.351 in TMJs affected with disc displacement, and 1.084+-0.172 in TMJs of controls Significant differences were demonstrated among them(p<001). Difference of both TMJ SUR was highest in patients with unilateral TMJ arthritis(0.608+-0.533, p<001), and there is no significant difference between that of controls and that of unilateral TMJ disc displacement patients(0.062+-0.063 vs 0.122+-0.100). TMJ SUR of joint with bone change on X-ray finding was not significantly different from that of joint with normal X-ray finding. Those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). The proportions of patients with increased TMJ SUR and difference of both TMJ SUR(>mean+2SD of controls) in unilateral TMJ arthritis patients were significantly higher than those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). Conclusively, bone scan may help to detect TMJ disease and differentiate TMJ disc displacement from TMJ arthritis.

  12. Automatic Vertebral Column Extraction by Whole-Body Bone SPECT Scan

    Directory of Open Access Journals (Sweden)

    Sheng-Fang Huang

    2013-01-01

    Full Text Available Bone extraction and division can enhance the accuracy of diagnoses based on whole-body bone SPECT data. This study developed a method for using conventional SPECT for automatic recognition of the vertebral column. A novel feature of the proposed approach is a novel “bone graph" image description method that represents the connectivity between these image regions to facilitate manipulation of morphological relationships in the skeleton before surgery. By tracking the paths shown on the bone graph, skeletal structures can be identified by performing morphological operations. The performance of the method was evaluated quantitatively and qualitatively by two experienced nuclear medicine physicians. Datasets for whole-body bone SPECT scans in 46 lung cancer patients with bone metastasis were obtained with Tc-99m MDP. The algorithm successfully segmented vertebrae in the thoracolumbar spine. The quantitative assessment shows that the segmentation method achieved an average TP, FP, and FN rates of 95.1%, 9.1%, and 4.9%. The qualitative evaluation shows an average acceptance rate of 83%, where the data for the acceptable and unacceptable groups had a Cronbach’s alpha value of 0.718, which indicated reasonable internal consistency and reliability.

  13. Scanning electron microscope studies of bone samples: Influence of simulated microgravity

    Science.gov (United States)

    Mehta, Rahul; Chowdhury, Parimal; Ali, Nawab

    2007-08-01

    A scanning electron microscope (SEM) with backscatter and secondary electron emission detectors plus a Si(Li) detector for photon yield measurements was used to study bone samples from skull and leg of mice and rats. These animals were either suspended by their tail to induce simulated microgravity, characterized as hind-limb suspension (HLS) or not suspended (control). Analyses of the SEM images and energy dispersive spectrometer (EDS) spectra using Si(Li) detector indicate variation in the lattice structures, and in intensities of the characteristics X-rays, produced from the exposed bone surface due to its interaction with the electron beam. Using Flame software, the X-ray spectra were analyzed and normalized ratios of the elements determined. The elemental analysis indicated a variation in the density of calcium, potassium, and oxygen near the knee joints and near the sutures in the skull bones. The comparison of simulated microgravity subjected samples of the rat skull bones with that of the control samples revealed that in the suture region there was a large increase in the ratio of calcium, and to some degree for phosphorus, suggesting simulated microgravity affects distribution of these elements. Elemental composition for control samples with depth (within the cross section of the leg bones) revealed decrease of oxygen and increase of calcium in the first millimeter of the bone depth after which the relative percentage of elements stayed constant.

  14. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  15. Chronic recurrent multifocal osteomyelitis demonstrated by Tc-99m methylene diphosphonate bone scan

    DEFF Research Database (Denmark)

    Lise, Hobolt; Nemery, Michel; Albrectsen, Jens;

    2008-01-01

    A 12-year-old Middle Eastern girl presented with abdominal pain, weight loss, and intermittent pain in both thighs. She was initially suspected of Crohn disease, but this diagnosis was excluded after extensive gastromedical evaluation. Plain x-rays of the femora were normal, whereas the initial T...... osteomyelitis (CRMO). The patient's symptoms disappeared spontaneously, but reappeared 1.5 years later, which led to a new MDP bone scan that showed normal findings. Udgivelsesdato: 2008-Jan...

  16. Calciphylaxis on bone scan: correlation between molecular and cross-sectional findings

    Directory of Open Access Journals (Sweden)

    Malak Itani, MD

    2017-03-01

    Full Text Available Calciphylaxis is a rare devastating medical condition commonly associated with end-stage renal disease and characterized by extensive microvascular calcifications. We describe a case of calciphylaxis presenting on Tc-99m MDP bone scan imaging with asymmetric radiotracer uptake within the lower extremities corresponding to extensive soft tissue calcifications on Computed tomography. Familiarity with the classic clinical presentation and imaging features of this rare entity may help its early identification and treatment.

  17. False negative bone scans in pediatric sepsis of the axial skeleton

    Energy Technology Data Exchange (ETDEWEB)

    Perloff, K.G.; Glancy, G.L.; Perloff, J.J.

    1988-12-01

    The early diagnosis of disk space infections and sacroiliitis in children can be difficult because of protean presenting symptoms, nonspecific laboratory studies, and normal plain films. Technetium phosphate scintigraphy has been reported as a diagnostic method with an accuracy of up to 100% in some series. In this case report we present two patients with negative technetium bone scans in the face of active infection, illustrating the need to pursue the diagnosis using other modalities.

  18. A Study on Clinical Activity of Myositis by the Use of Radioisotope Bone Scan in the Patients with Dermatomyositis - polymyositis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sung Jae; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1982-03-15

    To evaluate the diagnostic usefulness of radioisotope bone scan and clinical activity of myositis, bone scan using {sup 99m}Tc-Methylene diphosphonate was serially done before and after treatment with prednisolone in 10 patients with well- documented dermatomyositis-polymyositis. The observed results were as follows. 1. In all 10 patients before treatment with prednisolone, the bone scans showed evidence of increased muscle uptake. Muscle uptake was markedly increased in 4 patients, moderately increased in 3 patients and minimally increased in 3 patients. 2. The site of increased muscle uptake was consistent with the site of clinically involved muscle which was weak and tender. 3. The degree of muscle uptake correlated with the severity of the muscle weakness and tenderness at the scan was done. In all 10 patients treated with high dose prednisolone, muscle uptake was decreased following therapy. Above results suggest the radioisotope bone scanning may be useful in the diagnosis and treatment of patient with dermatomyositis-polymyositis.

  19. Radionuclide Ventriculography or Radionuclide Angiography (MUGA Scan)

    Science.gov (United States)

    ... Non-invasive - Invasive • Treatment of a Heart Attack • Life After a Heart Attack • Heart Attack Tools & Resources • Support Network Subscribe to Heart Insight magazine and monthly e-newsletter Our digital magazine delivers ...

  20. Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant Lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Sung Min; Nam, Hyun Yeol; Kim, In Ju; Kim, Yong Ki [Pusan National University Hospital, Pusan (Korea, Republic of); Kim, Ju Sung [College of Medical Life Science, Silla University, Pusan (Korea, Republic of)

    2008-06-15

    Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p<0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p=0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

  1. A pediatric bone mass scan has poor ability to predict adult bone mass: a 28-year prospective study in 214 children.

    Science.gov (United States)

    Buttazzoni, Christian; Rosengren, Bjorn E; Tveit, Magnus; Landin, Lennart; Nilsson, Jan-Åke; Karlsson, Magnus K

    2014-02-01

    As the correlation of bone mass from childhood to adulthood is unclear, we conducted a long-term prospective observational study to determine if a pediatric bone mass scan could predict adult bone mass. We measured cortical bone mineral content (BMC [g]), bone mineral density (BMD [g/cm(2)]), and bone width (cm) in the distal forearm by single photon absorptiometry in 120 boys and 94 girls with a mean age of 10 years (range 3-17) and mean 28 years (range 25-29) later. We calculated individual and age-specific bone mass Z scores, using the control cohort included at baseline as reference, and evaluated correlations between the two measurements with Pearson's correlation coefficient. Individual Z scores were also stratified in quartiles to register movements between quartiles from growth to adulthood. BMD Z scores in childhood and adulthood correlated in both boys (r = 0.35, p pediatric bone scan with a value in the lowest quartile had a sensitivity of 48% (95% confidence interval [CI] 27-69%) and a specificity of 76% (95% CI 66-84%) to identify individuals who would remain in the lowest quartile also in adulthood. Childhood forearm BMD explained 12% of the variance in adult BMD in men and 25% in women. A pediatric distal forearm BMD scan has poor ability to predict adult bone mass.

  2. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    Science.gov (United States)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  3. Alternative oblique head CT scanning technique reduces bone artifact and improves interpretability of brainstem anatomy

    Directory of Open Access Journals (Sweden)

    Sam Douglas Kampondeni

    2010-06-01

    Full Text Available Brainstem pathology due to infections, infarcts and tumors are common in developing countries, but neuroimaging technology in these resource-poor settings is often limited to single slice, and occasionally spiral, CT. Unlike multislice CT and MRI, single slice and spiral CT are compromised by bone artifacts in the posterior fossa due to the dense petrous bones, often making imaging of the brainstem non-diagnostic. With appropriate head positioning, the petrous ridges can be avoided with 40˚ sagittal oblique scans parallel to either petrous ridge. We describe an alternative sagittal oblique scanning technique that significantly reduces brainstem CT artifacts thereby improving clarity of anatomy. With Inst­itutional Ethical approval, 13 adult patients were enrolled (5 males; 39%. All patients had routine axial brain CT and sagittal oblique scans with no lesions found. Images were read by 2 readers who gave a score for amount of artefact and clarity of structures in the posterior fossa. The mean artifact score was higher for routine axial images compared to sagittal oblique (2.92 vs. 1.23; P<0.0001. The mean anatomical certainty scores for the brainstem were significantly better in the sagittal oblique views compared to routine axial (1.23 vs. 2.77; P<0.0001. No difference was found between the two techniques with respect to the fourth ventricle or the cerebellum (axial vs. sag oblique: 1.15 vs. 1.27; P=0.37. When using single slice CT, the sagittal oblique scanning technique is valuable in improving clarity of anatomy in the brainstem if axial images are non-diagnostic due to bone artifacts.

  4. Correction of step artefact associated with MRI scanning of long bones.

    Science.gov (United States)

    Rathnayaka, Kanchana; Cowin, Gary; Schuetz, Michael A; Sahama, Tony; Schmutz, Beat

    2013-07-01

    3D models of long bones are being utilised for a number of fields including orthopaedic implant design. Accurate reconstruction of 3D models is of utmost importance to design accurate implants to allow achieving a good alignment between two bone fragments. Thus for this purpose, CT scanners are employed to acquire accurate bone data exposing an individual to a high amount of ionising radiation. Magnetic resonance imaging (MRI) has been shown to be a potential alternative to computed tomography (CT) for scanning of volunteers for 3D reconstruction of long bones, essentially avoiding the high radiation dose from CT. In MRI imaging of long bones, the artefacts due to random movements of the skeletal system create challenges for researchers as they generate inaccuracies in the 3D models generated by using data sets containing such artefacts. One of the defects that have been observed during an initial study is the lateral shift artefact occurring in the reconstructed 3D models. This artefact is believed to result from volunteers moving the leg during two successive scanning stages (the lower limb has to be scanned in at least five stages due to the limited scanning length of the scanner). As this artefact creates inaccuracies in the implants designed using these models, it needs to be corrected before the application of 3D models to implant design. Therefore, this study aimed to correct the lateral shift artefact using 3D modelling techniques. The femora of five ovine hind limbs were scanned with a 3T MRI scanner using a 3D vibe based protocol. The scanning was conducted in two halves, while maintaining a good overlap between them. A lateral shift was generated by moving the limb several millimetres between two scanning stages. The 3D models were reconstructed using a multi threshold segmentation method. The correction of the artefact was achieved by aligning the two halves using the robust iterative closest point (ICP) algorithm, with the help of the overlapping

  5. Radioisotope scanning of brain, liver, lung and bone with a note on tumour localizing agents

    Science.gov (United States)

    Lavender, J. P.

    1973-01-01

    Radioisotopic scanning of brain, liver, lungs and the skeleton is briefly reviewed with a survey of recent developments of clinical significance. In brain scanning neoplasm detection rates of greater than 90% are claimed. The true figure is probably 70-80%. Autopsy data shows a number of false negatives, particularly with vascular lesions. Attempts to make scanning more specific in differentiating neoplasm from vascular lesions by rapid sequence blood flow studies are reviewed. In liver scanning by means of colloids again high success rate is claimed but small metastases are frequently missed and the false negative scan rate is probably quite high. Lung scanning still has its main place in investigating pulmonary embolic disease. Ventilation studies using Xenon 133 are useful, particularly combined with perfusion studies. The various radiopharmaceuticals for use in bone scanning are reviewed. The appearance of technetium labelled phosphate compounds will probably allow much wider use of total skeletal scanning. Research into tumour localizing agents continues, the most recent and interesting being Gallium citrate and labelled bleomycin. Neither agent is predictable however although Gallium may have a place in Hodgkins disease and bronchogenic neoplasm and both may have a place in the detection of cerebral tumours. ImagesFig. 1Fig. 2Fig. 3p452-bFig. 3bFig. 4Fig. 5Fig. 5bFig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 12c & 12dFig. 13Fig. 13 b,c,dFig. 14Fig. 14bFig. 15Fig. 15bFig. 16Fig. 17Fig. 18 PMID:4602127

  6. Microwave bone imaging: a preliminary scanning system for proof-of-concept.

    Science.gov (United States)

    Ruvio, Giuseppe; Cuccaro, Antonio; Solimene, Raffaele; Brancaccio, Adriana; Basile, Bruno; Ammann, Max J

    2016-09-01

    This Letter introduces a feasibility study of a scanning system for applications in biomedical bone imaging operating in the microwave range 0.5-4 GHz. Mechanical uncertainties and data acquisition time are minimised by using a fully automated scanner that controls two antipodal Vivaldi antennas. Accurate antenna positioning and synchronisation with data acquisition enables a rigorous proof-of-concept for the microwave imaging procedure of a multi-layer phantom including skin, fat, muscle and bone tissues. The presence of a suitable coupling medium enables antenna miniaturisation and mitigates the impedance mismatch between antennas and phantom. The three-dimensional image of tibia and fibula is successfully reconstructed by scanning the multi-layer phantom due to the distinctive dielectric contrast between target and surrounding tissues. These results show the viability of a microwave bone imaging technology which is low cost, portable, non-ionising, and does not require specially trained personnel. In fact, as no a-priori characterisation of the antenna is required, the image formation procedure is very conveniently simplified.

  7. Routine bone scintigraphy in primary staging of soft tissue sarcoma - Is it worthwhile?

    NARCIS (Netherlands)

    Jager, PL; Hoekstra, HJ; Leeuw, JA; van der Graaf, WTA; de Vries, EGE; Piers, DA

    2000-01-01

    BACKGROUND. The incidence of bone metastases in soft tissue sarcoma (STS) patients seems to be low but has not been studied separately. In this study, the authors aimed to determine the value of routine radionuclide bone scanning in preoperative staging of STS patients. METHODS. Preoperative bone

  8. Routine bone scintigraphy in primary staging of soft tissue sarcoma - Is it worthwhile?

    NARCIS (Netherlands)

    Jager, PL; Hoekstra, HJ; Leeuw, JA; van der Graaf, WTA; de Vries, EGE; Piers, DA

    2000-01-01

    BACKGROUND. The incidence of bone metastases in soft tissue sarcoma (STS) patients seems to be low but has not been studied separately. In this study, the authors aimed to determine the value of routine radionuclide bone scanning in preoperative staging of STS patients. METHODS. Preoperative bone sc

  9. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    Energy Technology Data Exchange (ETDEWEB)

    Yunus, Barunawaty [Faculty of Dentistry, Hasanuddin University, Makassar (Malaysia)

    2011-06-15

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  10. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    Science.gov (United States)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  11. Radionuclide cystogram

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003832.htm Radionuclide cystogram To use the sharing features on this page, please enable JavaScript. A radionuclide cystogram is a special imaging test called a nuclear ...

  12. Scanning transmission electron microscopic tomography of cortical bone using Z-contrast imaging.

    Science.gov (United States)

    McNally, Elizabeth; Nan, Feihong; Botton, Gianluigi A; Schwarcz, Henry P

    2013-06-01

    Previously we presented (McNally et al., 2012) a model for the ultrastructure of bone showing that the mineral resides principally outside collagen fibrils in the form of 5 nm thick mineral structures hundreds of nanometers long oriented parallel to the fibrils. Here we use high-angle annular dark-field electron tomography in the scanning transmission electron microscope to confirm this model and further elucidate the composite structure. Views of a section cut parallel to the fibril axes show bundles of mineral structures extending parallel to the fibrils and encircling them. The mineral density inside the fibrils is too low to be visualized in these tomographic images. A section cut perpendicular to the fibril axes, shows quasi-circular walls composed of mineral structures, wrapping around apparently empty holes marking the sites of fibrils. These images confirm our original model that the majority of mineral in bone resides outside the collagen fibrils.

  13. Incidental detection of gastrointestinal stromal tumor by Tc-99m MDP bone scan.

    Science.gov (United States)

    Shepherd, Timothy M; Idakoji, Ibrahim A; Pampaloni, Miguel H

    2012-02-01

    This case demonstrates extraosseous 99m-technetium methylene diphosphonate (Tc-99m MDP) accumulation from a gastrointestinal stromal tumor. A 75-year-old woman underwent a temporal bone CT for conductive hearing loss that showed sclerosis in the right occipital condyle. Follow-up Tc-99m MDP bone scan for osseous metastases instead showed a mass-like extraosseous accumulation of Tc-99m MDP in the anterior left upper quadrant. Differential diagnoses included gastric cancer, lymphoma, metastatic melanoma, systemic hypercalcemia, or heterotopic mesenteric ossification. Contrast CT showed a well-circumscribed mass arising from the stomach, and subsequent pathology confirmed gastrointestinal stromal tumor. These tumors rarely can contain osteoclast-like giant cells and should be considered for extraosseous Tc-99m MDP accumulation.

  14. Radionuclides and trace elements in fish collected upstream and downstream of Los Alamos National Laboratory and the doses to humans from the consumption of muscle and bone.

    Science.gov (United States)

    Fresquez, P R; Kraig, D H; Mullen, M A; Naranjo, L

    1999-09-01

    The purpose of this study was to determine radionuclide and trace element concentrations in bottom-feeding fish (catfish, carp, and suckers) collected from the confluences of some of the major canyons that cross Los Alamos National Laboratory (LANL) lands with the Rio Grande (RG) and the potential radiological doses from the ingestion of these fish. Samples of muscle and bone (and viscera in some cases) were analyzed for 3H, 90Sr, 137Cs, totU, 238Pu, 239,240Pu, and 241Am and Ag, As, Ba, Be, Cr, Cd, Cu, Hg, Ni, Pb, Sb, Se, and Tl. Most radionuclides, with the exception of 90Sr, in the muscle plus bone portions of fish collected from LANL canyons/RG were not significantly (p < 0.05) higher from fish collected upstream (San Ildefonso/background) of LANL. Strontium-90 in fish muscle plus bone tissue significantly (p < 0.05) increases in concentration starting from Los Alamos Canyon, the most upstream confluence (fish contained 3.4E-02 pCi g-1 [126E-02 Bq kg-1]), to Frijoles Canyon, the most downstream confluence (fish contained 14E-02 pCi g-1 [518E-02 Bq kg-1]). The differences in 90Sr concentrations in fish collected downstream and upstream (background) of LANL, however, were very small. Based on the average concentrations (+/- 2SD) of radionuclides in fish tissue from the four LANL confluences, the committed effective dose equivalent from the ingestion of 46 lb (21 kg) (maximum ingestion rate per person per year) of fish muscle plus bone, after the subtraction of background, was 0.1 +/- 0.1 mrem y-1 (1.0 +/- 1.0 microSv y-1), and was far below the International Commission on Radiological Protection (all pathway) permissible dose limit of 100 mrem y-1 (1000 microSv y-1). Of the trace elements that were found above the limits of detection (Ba, Cu, and Hg) in fish muscle collected from the confluences of canyons that cross LANL and the RG, none were in significantly higher (p < 0.05) concentrations than in muscle of fish collected from background locations.

  15. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Caricasulo, D. [Orthopaedics Dept., General Hospital of Bassano del Grappa (Italy); Borsato, N. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy)

    1996-10-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic {sup 99m}TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  16. Prognostic value of bone marrow tracer uptake pattern in baseline PET scan in Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Zwarthoed, Colette; El-Galaly, Tarec Cristoffer; Canepari, Maria

    2017-01-01

    RATIONALE: Positron Emission Tomography/Computed Tomography (PET/CT)-ascertained bone marrow involvement (BMI) constitutes the single most important reason for upstaging by PET/CT in Hodgkin lymphoma (HL). However, BMI assessment in PET/CT can be challenging. This study analysed the clinico.......03). The kappa-values for inter-observer agreement were 0.84 for focal uptake and 0.78 for diffuse uptake. CONCLUSION: We confirmed that FDG-PET scan is a reliable tool for BMI assessment in HL and BMB is no longer needed for routine staging. Moreover, the inter-observer agreement for BMI in this study proved...

  17. Sensitivity of radionuclide brain scan and computed tomography in early detection of viral meningoencephalitis. [/sup 99m/Tc-DTPA or /sup 99m/Tc-sodium pertechnetate

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E.E.; DeLand, F.H.; Montebello, J.

    1979-08-01

    The sensitivity of radionuclide imaging and computed tomography (CT) was evaluated in 25 patients for early detection of viral meningoencephalitis. Diagnosis was based on clinical evidence, cerebrospinal fluid (CSF) studies, electroencephalography (EEG) and radionuclide imaging. Computed tomography with contrast enhancement was performed within four days after onset of neurological signs or symptoms in 23 patients; no significant findings such as low-absorption abnormalities, mass effect or abnormal enhancement were seen. Radionuclide imaging demonstrated a sensitivity of 90% in the detection of viral meningoencephalitis; the temporal lobe was most commonly involved in patients with herpes encephalitis. Radionuclide imaging should be considered as the first diagnostic procedure in suspected early viral meningoencephalitis.

  18. Bone metastasis versus bone marrow metastasis? Integration of diagnosis by 18F-fluorodeoxyglucose positron emission/computed tomography in advanced malignancy with super bone scan: Two case reports and literature review

    Directory of Open Access Journals (Sweden)

    Chia-Yang Lin

    2013-04-01

    Full Text Available Super scan pattern on technetium-99m methyldiphosphonate (Tc-99m MDP bone scintigraphy is a special condition of extremely high bone uptake relative to soft tissue with absent or faint renal radioactivity visualization, which is usually seen in diffuse bone metastases or discrete endocrine entities. Here, two cases with super bone scan are presented. One was a young man diagnosed with gastric cancer. The other was a middle-aged woman with a history of breast cancer with recent recurrence. Both cases had 18-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT diagnosis simultaneously. Based on imaging of 18F-FDG PET/CT, diffusely incremental 18F-FDG avidity in spine/pelvis on PET and subtle erosion of cortical bone on CT were seen. The cytological results of bone marrow biopsy showed evidence of malignant metastasis. However, there were several focal discrepant findings between the 18F-FDG PET/CT and Tc-99m MDP bone scan. According to integration of both imaging findings and the result of bone marrow biopsy, we believe that the disseminated malignant spread in bone marrow is a primitive alternation in the super bone scan and that it is also as a result of neoplasm-related endocrine factors.

  19. A Pediatric Bone Mass Scan has Poor Ability to Predict Peak Bone Mass: An 11-Year Prospective Study in 121 Children.

    Science.gov (United States)

    Buttazzoni, Christian; Rosengren, Bjorn E; Karlsson, Caroline; Dencker, Magnus; Nilsson, Jan-Åke; Karlsson, Magnus K

    2015-05-01

    This 11-year prospective longitudinal study examined how a pre-pubertal pediatric bone mass scan predicts peak bone mass. We measured bone mineral content (BMC; g), bone mineral density (BMD; g/cm(2)), and bone area (cm(2)) in femoral neck, total body and lumbar spine by dual-energy X-ray absorptiometry in a population-based cohort including 65 boys and 56 girls. At baseline all participants were pre-pubertal with a mean age of 8 years (range 6-9), they were re-measured at a mean 11 years (range 10-12) later. The participants were then mean 19 years (range 18-19), an age range that corresponds to peak bone mass in femoral neck in our population. We calculated individual BMC, BMD, and bone size Z scores, using all participants at each measurement as reference and evaluated correlations between the two measurements. Individual Z scores were also stratified in quartiles to register movements between quartiles from pre-pubertal age to peak bone mass. The correlation coefficients (r) between pre-pubertal and young adulthood measurements for femoral neck BMC, BMD, and bone area varied between 0.37 and 0.65. The reached BMC value at age 8 years explained 42 % of the variance in the BMC peak value; the corresponding values for BMD were 31 % and bone area 14 %. Among the participants with femoral neck BMD in the lowest childhood quartile, 52 % had left this quartile at peak bone mass. A pediatric bone scan with a femoral neck BMD value in the lowest quartile had a sensitivity of 47 % [95 % confidence interval (CI) 28, 66] and a specificity of 82 % (95 % CI 72, 89) to identify individuals who would remain in the lowest quartile at peak bone mass. The pre-pubertal femoral neck BMD explained only 31 % of the variance in femoral neck peak bone mass. A pre-pubertal BMD scan in a population-based sample has poor ability to predict individuals who are at risk of low peak bone mass.

  20. Evaluate the diagnostic value of radionuclide bone imaging of metastatic spine tumors%放射性核素骨显像在脊柱转移瘤诊断中的价值

    Institute of Scientific and Technical Information of China (English)

    白剑强; 夏群; 胡永成

    2011-01-01

    Metastatic spine tumors(MST)can occur in many primary,malignant tumors,but X-ray cannot find early metastatic disease;CT scans can not directly show abnormity of the spinal marrow;MRI need a long time,patients with spinal tumors can hardly to be suffered which will affect image quality.Conventional bone scan has the ability to scan the entire skeleton,but the specificity is not high.However,the sensitivity and specificity can be improved about the diagnosis of MST by bone SPECT imaging,the distribution of the anatomical structure or morphology of the metastatic spinal tumors can be clearly displayed.PET-CT could detect the metastases of spine and other parts of the body sensitively and accurately,primary tumors that were unknown before examination couhl be found at the same time.This paper describes the diagnostic value of radionuclide bone scintigraphy of MST.%脊柱转移瘤(MST)可发生于原发恶性肿瘤临床的各个阶段,传统X线片发现时多为中晚期病变;CT容易漏诊,不能直接显示脊髓的异常;MRI耗时长,病痛的患者不易配合,影响图像的质量.常规骨扫描能够对整个骨骼进行扫描,但特异性不高.核素SPECT骨显像可提高对MST诊断的敏感性和特异性,提示病灶累及的解剖结构或分布形态,并能定量分析放射性浓聚灶;PET-CT能够清楚鉴别脊柱病变,实现早期诊断,并可早期评估化疗或放疗疗效.该文进一步阐述核素骨显像在MST早期诊断中的价值.

  1. Omission of bone scanning according to staging guidelines leads to futile therapy in non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schirrmeister, Holger [Department of Nuclear Medicine, University of Kiel, Kiel (Germany); Arslandemir, Coskun; Hetzel, Martin [Department of Internal Medicine II, University of Ulm, Robert-Koch-Strasse 8, 89081, Ulm (Germany); Glatting, Gerhard; Buck, Andreas [Department of Nuclear Medicine, University of Ulm, Ulm (Germany); Mayer-Steinacker, Regine; Bommer, Martin [Department of Hematology and Oncology, University of Ulm, Ulm (Germany); Dreinhoefer, Karsten [Department of Orthopedics, University of Ulm, Ulm (Germany)

    2004-07-01

    The leading European and American professional societies recommend that bone scans (BS) should be performed in the staging of lung cancer only in those patients with bone pain. This prospective study investigated the sensitivity of conventional skeletal scintigraphy in detecting osseous metastases in patients with lung cancer and addressed the potential consequences of failure to use this method in the work-up of asymptomatic patients. Subsequent to initial diagnosis of non-small cell lung cancer, 100 patients were examined and questioned regarding skeletal complaints. Two specialists in internal medicine decided whether they would recommend a bone scan on the basis of the clinical evaluation. Skeletal scintigraphy was then performed blinded to the findings of history and physical examination. The combined results of magnetic resonance imaging (MRI) of the vertebral column, positron emission tomography (PET) of skeletal bone and the subsequent clinical course served as the gold standard for the identification of osseous metastases. Bone scintigraphy showed an 87% sensitivity in the detection of bone metastases. Failure to perform skeletal scintigraphy in asymptomatic patients reduced the sensitivity of the method, depending on the interpretation of the symptoms, to 19-39%. Without the findings of skeletal scintigraphy and the gold standard methods, 14-22% of patients would have undergone unnecessary surgery or neoadjuvant therapy. On this basis it is concluded that bone scans should not be omitted in asymptomatic patients. (orig.)

  2. Peptide receptor radionuclide therapy with lutetium-177 DOTATATE in a case of recurrent extradrenal retroperitoneal malignant paraganglioma with nodal and bone metastasis

    Directory of Open Access Journals (Sweden)

    Koramadai Karuppusamy Kamaleshwaran

    2015-01-01

    Full Text Available Extra-adrenal retroperitoneal paragangliomas (PGLs are rare tumors causing considerable difficulty in both, diagnosis and treatment. They can be unicentric or multicentric, tend to be locally invasive and therefore have a high incidence of local recurrence. PGLs shows somatostatin receptor positivity, which can be imaged with technetium-99m (Tc-99m-hydrazinonicotinyl-Tyr3-octreotide (HYNIC-TOC and can be treated with lutetium-177 (Lu-177 DOTATATE. We present a case of recurrent unresectable retroperitoneal PGL with nodal and bone metastases in a 27-year-old male, 6 months postsurgery detected with Tc-99m-HYNIC-TOC and was administered with peptide receptor radionuclide therapy using Lu-177 DOTATATE.

  3. The value of radionuclide bone imaging on monitoring chemotherapeutic effects of multiple myeloma%核素骨显像在多发性骨髓瘤疗效评价中的应用

    Institute of Scientific and Technical Information of China (English)

    Yongli Bai; Shuyao Zuo; Chao Ma; Xiaoting Su

    2008-01-01

    Objective: To investigate the value of radionuclide whole-body bone imaging on monitoring chemotherapeutic effects for multiple myeloma (MM). Methods: Sixty patients were included. Twenty nine cases received CTD (thalidomide 100-200 mg/d; cyclophosphamide 200-300 mg/m2·d, 1-4 days, every 4 weeks; and dexamethasone 20-40 rag/d, 1-4 days, every 4 weeks); Thirty cases received VAD (vincristine 0.4 mg/d, 1-4 days, every 4 weeks; adriamycin 10 rag/d, 1-4 days, ev-ery 4 weeks; dexamethasone 40 mg/d, 1-4 days, every 4 weeks). Radionuclide bone imagings were performed in all patients before chemotherapy, six months, twelve months and eighteen months after chemotherapy. The correlation of chemotherapeutic effects between CTD and VAD were analyzed. Results: One hundred and seventy nine bone lesions were visualized by bone scintigraphy before CTD treatment. Eighteen months after CTD chemotherapy, it was observed by bone scintigraphy that 39/179 (21.78%) lesions disappeared, 112/179 (62.57%)improved, and 28/179 (15.64%) had no change. One hundred and ninety one bone lesions were showed by bone imaging before VAD treatment, 36/191 (18.84%) lesions disappeared, eighteen months after chemotherapy, 103/191 (53.92%) improved, and 52/191 (27.22%) had no change. The significant difference was observed in locations of MM induced bone lesions treated with CTD (H = 8.23, P < 0.05) and VAD (H = 11.18, P < 0.05). A significant chemotherapeutic sensitivity in detecting MM induced lesions in ribs was found compared with other bone lesions. The chemotherapeutic effect of CTD was statistically significant than that of VAD (U = 2.17, P < 0.05). Conclusion: Radionuclide whole-body bone imaging has great value in monitoring chemotherapeutic effects for MM.

  4. Cosmogenic radionuclides

    CERN Document Server

    Beer, Jürg; Von Steiger, R

    2012-01-01

    Cosmogenic radionuclides are radioactive isotopes which are produced by natural processes and distributed within the Earth system. With a holistic view of the environment the authors show in this book how cosmogenic radionuclides can be used to trace and to reconstruct the history of a large variety of processes. They discuss the way in which cosmogenic radionuclides can assist in the quantification of complex processes in the present-day environment. This book aims to demonstrate to the reader the strength of analytic tools based on cosmogenic radionuclides, their contribution to almost any f

  5. Wholebody and pinhole bone scan manifestations of reiter's syndorme: distribution pattern and specific and early signs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Chung, S. K.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Han, B. H.; Bahk, Y. W. [College of Medicine, Catholic Univ., Seoul (Korea, Republic of)

    1998-07-01

    We wish to describe the characteristics panoramic wholebody bone distribution, and specific and preradiographic pinhole bone scan signs of Reiter's syndrome(RS) featured by pauciarthritis and enthesopathies in and about weight-bearing joints of the lower extremities and axial bones. We analyzed 55 sets of wholebody and pinhole bone scintigraphs of 55 patients with RS. The population was 44 men and 11 women with age ranging from 15 to 52 yr (mean=29.3). The scintigraphy was performed 2-2.5 hr pi of Tc-99m-HDP using a single-head gamma camera with a LEHR collimator and a 4-mm pinhole collimator for the wholebody and pinhole scintigraphy, respectively. We found 223 lesions with increased tracer uptake in total. Wholebody scans showed asymmetric pauciarticular distribution in weight bearing joints and periarticular entheses in the lower extremities in 63.2% (calcaneus=24.2%, ankle=8.1%, tibia=8.1% and others). The sternum, sacroiliac joint and spine were involved in 8.5%, 5.8% and 4.5%, respectively. Pinhole scan portrayed many specific signs including the 'tear-drop' sign of paravertebral ossification. 'whiskers' sign of femoral osteophytes and 'knuckle bone' sign of sausage digit. Twenty-four lesions (10.8%) showed preradiogrpahic signs in symptomatic ehthesopathies mostly in the calcaneus and proximal tibia. Nine cases with calcaneal enthesopathies and four cases with proximal tibial enthesopathy without radiographic bone change showed intense tracer uptake. Wholebody and pinhole magnification scans were useful in studying RS. The asymmetric pauciarticular distribution in the weight-bearing bones with enthesopathies was characteristic. Pinhole scan portrayed many specific signs and was sensitive permitting accurate preradiographic diagnosis in many cases.

  6. Does the presence of glenoid bone loss influence coracoid bone graft osteolysis after the Latarjet procedure? A computed tomography scan study in 2 groups of patients with and without glenoid bone loss.

    Science.gov (United States)

    Di Giacomo, Giovanni; de Gasperis, Nicola; Costantini, Alberto; De Vita, Andrea; Beccaglia, Mario A Rojas; Pouliart, Nicole

    2014-04-01

    Coracoid bone graft osteolysis and fibrous union are the principal causes of failure in patients treated with the Latarjet procedure. This study aims to investigate the hypothesis that coracoid bone graft osteolysis is more pronounced in cases without glenoid bone loss, which may be due to a diminished mechanotransduction effect at the bone healing site. We prospectively followed up 34 patients, treated with a mini-plate Latarjet procedure, divided into 2 groups (group A patients had glenoid bone loss >15% and group B patients had no glenoid bone loss). A computed tomography scan evaluation with 3-dimensional reconstruction was then performed on all patients to evaluate coracoid bone graft osteolysis according to our coracoid bone graft osteolysis classification. The computed tomography scan analysis showed a different distribution of osteolysis between group A and group B. The statistical analysis showed a significant difference (P 15%) than in those without it. Because factors of blood supply, compression, and surgical technique were the same for both groups, we believe that the mechanotransduction effect from the humeral head on the graft influences its remodeling. The results of this study suggest that the bone graft part of the Latarjet procedure plays a role in patients with significant coracoid bone loss but much less so when there is no bone loss. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Constructing a multi-scan synchrotron X-ray microscope to study the function of osteocyte canaliculi in mouse bone

    Energy Technology Data Exchange (ETDEWEB)

    Nango, Nobuhito; Kubota, Shogo; Yashiro, Wataru; Momose, Atsushi; Takada, Yasunari; Matsuo, Koichi [Ratoc System Engineering Co., Ltd, Toho Edogawabashi Bldg. 4F, 1-24-8 Sekiguchi, Bunkyo-ku, Tokyo 112-0014 (Japan); Dept. of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-shi, Chiba 277-8561 (Japan); Lab. of Cell and Tissue Biology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan)

    2012-07-31

    Formulating a multi-scan method applied to an X-ray microscope CT with synchrotron radiation, we attempted to analyze the 3D functional structure of osteocyte canaliculi inside the cortical bone of a mouse tibia. We employed a two-method combination to scan the same position of the specimen. To extract the internal bone canalicular structure, we first combined a Talbot interferometer with an X-ray microscope, and applied a differential phase imaging method to measure the absolute value of bone mineral around the canaliculi. Next, we used the X-ray microscope without the Talbot interferometer under a defocus condition, moving the specimen toward the zone plate by 6 mm. This defocus contrast method visualizes the canaliculi by emphasizing the edges of the bone. We performed CT scans by the two configurations and precisely aligned resultant 3D images so that the same position in the specimen is compared. We could extract the osteocyte canaliculi and evaluate the mineral density of their surroundings. The degree of mineralization varied for each osteocyte lacuna and canaliculus. The multi-scan microscopic X-ray CT is a powerful tool for analyzing bone mineralization.

  8. Spinal uptake mimicking metastasis in SPECT/CT bone scan in a patient with superior vena cava obstruction.

    Science.gov (United States)

    Rager, Olivier; Nkoulou, René; Garibotto, Valentina; Boudabbous, Sana; Arditi, Daniel

    2013-11-01

    A 46-year-old female patient with a mediastinal neuroendocrine carcinoma complicated by superior vena cava syndrome was referred for a bone metastatic workup. Bone scan with SPECT/CT showed several vertebral fixations without alterations on the unenhanced CT, but a CT scan with injection of contrast media showed vertebral densities matched to the lesions described on the SPECT/CT. This pattern confirmed presence of collateral paths through vertebral veins due to superior vena cava syndrome. Lack of metastases was confirmed by MRI.

  9. Tumorlike Pigmented Villonodular Synovitis With Atypical Location: Appearance on 3-Phase 99mTc-MDP Bone Scan.

    Science.gov (United States)

    Hua, Qian; Ni, Jianming

    2017-03-01

    Pigmented villonodular synovitis (PVNS) is a proliferative disorder of unknown etiology that originates from the synovial membranes of joints. Some PVNS lesions have been misdiagnosed as malignancy due to their tumorlike imaging findings. There are few reports of PVNS on nuclear 3-phase bone imaging. However, 3-phase Tc-MDP bone scan can offer additional information about the dynamic flow features of the lesion, which may do help in differential benign and malignant. The present report describes 3-phase bone imaging in a surgically proven case of PVNS with tumorlike appearance and atypical location.

  10. The natural course of radionuclide bone scanning in the evaluation of total knee replacement--a 2 year prospective study

    DEFF Research Database (Denmark)

    Duus, B R; Boeckstyns, M; Stadeager, Carsten Preben

    1990-01-01

    completed the entire program. A total of 143 99Tcm medronic acid complex scintigrams was performed. No significant difference between the grades of total scintigraphic uptake at any of the four examinations nor any difference between the first and the last examinations could be demonstrated (P = 0...

  11. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Pastor Lopez, Maria Juana; Ulivieri, Fabio M. [Servizio di Medicina Nucleare, Ospedale Maggiore, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Milano (Italy); Mai, Alessandro [Universita degli Studi di Milano, Tecniche di Radiologia Medica, per Immagini e Radioterapia, Milano (Italy); Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-12

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 x CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm{sup -1}) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable. (orig.)

  12. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study.

    Science.gov (United States)

    Bandirali, Michele; Di Leo, Giovanni; Messina, Carmelo; Pastor Lopez, Maria Juana; Mai, Alessandro; Ulivieri, Fabio M; Sardanelli, Francesco

    2015-04-01

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 × CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm(-1)) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤ 2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable.

  13. Effect of View, Scan Orientation and Analysis Volume on Digital Tomosynthesis (DTS) Based Textural Analysis of Bone.

    Science.gov (United States)

    Kim, Woong; Oravec, Daniel; Divine, George W; Flynn, Michael J; Yeni, Yener N

    2017-05-01

    Digital tomosynthesis (DTS) derived textural parameters of human vertebral cancellous bone have been previously correlated to the finite element (FE) stiffness and 3D microstructure. The objective of this study was to optimize scanning configuration and use of multiple image slices in the analysis, so that FE stiffness prediction using DTS could be maximized. Forty vertebrae (T6, T8, T11, and L3) from ten cadavers (63-90 years) were scanned using microCT to obtain trabecular bone volume fraction (BV/TV) and FE stiffness. The vertebrae were then scanned using DTS anteroposteriorly (AP) and laterally (LM) while aligned axially (0°), transversely (90°) or obliquely (23°) to the superior-inferior axis of the vertebrae. From the serial DTS images, fractal dimension (FD), mean intercept length (MIL) and line fraction deviation (LFD) parameters were obtained from a 2D-single mid-stack location and 3D-multi-image stack. The DTS derived textural parameters were then correlated with FE stiffness using linear regression models within each scanning orientation. 3D-multi-image stack models obtained from Transverse-LM scanning orientation (90°) were most explanatory regardless of accounting for the effects of BV/TV. Therefore, DTS scanning perpendicular to the axis of the spine in an LM view is the preferred configuration for prediction of vertebral cancellous bone stiffness.

  14. A histomorphometric and scanning electron microscopy study of human condylar cartilage and bone tissue changes in relation to age

    DEFF Research Database (Denmark)

    Paulsen, Hans Ulrik; Thomsen, J.S.; Hougen, Hans Petter

    1999-01-01

    . EXPERIMENTAL SETTING AND DESIGN: A histomorphometric and scanning electron microscopic analysis of cartilage characteristics and bone remodelling activity. The Departments of Orthodontics and Cell Biology at Aarhus University, Denmark. An autopsy sample of condyles from 20 individuals, 18-31 years of age...

  15. Incidental neoplastics findings in paediatric {sup 99m}Tc-MDP bone scan patients with non-specific limp

    Energy Technology Data Exchange (ETDEWEB)

    Maddaford, S.; Morony, S. [Women`s and Children`s Hospital, North Adelaide, SA (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: A group of patients who attended the Department of Nuclear Medicine with non-specific limp/hip pain, for a {sup 99m}Tc-MDP bone scan, had incidental findings of diffuse neoplastic involvement. A variety of oncology patients attend the Department annually for a {sup 99m}Tc-MDP bone scan. These include patients with Ewing`s osteosarcoma, rhabdomyosarcoma, benign osteoid osteoma and neuroblastoma. We rarely see patients with leukemia. We found that of a number of patients with stage IV neuroblastoma 80% had presented to the Department with a non-specific limp/hip pain for investigation. The ESR in each case was either normal or raised, and previous radiological and ultrasound examination did not demonstrate any specific finding. The provisional diagnosis in each case was osteomyelitis or septic arthritis. In retrospect, a nuclear medicine {sup 99m}Tc-MDP bone scan was a clear advantage in assisting the diagnosis of neuroblastoma. A selection of these patient case studies is presented to demonstrate the value of the nuclear medicine bone scan incidental findings in the early diagnosis of neuroblastoma, and the subsequent monitoring and staging of this disease

  16. Clinical Analysis of Combined Examination of Bone Scan and Serum PSA in the Diagnosis and Treatment of Prostate Carcinoma%PSA和SPECT骨显像在前列腺癌诊断治疗中的意义

    Institute of Scientific and Technical Information of China (English)

    李斌; 张海滨; 廖黎黎

    2011-01-01

    Objective:To analysis of the combined detection of radionuclide bone imaging and plasma levels of prostate specific antigen (PSA) in patients with prostate cancer. Methods: Measure the serum PSA level and conduct bone scan on all the 100 patients that had been diagnosed as prostatic cancer. Results:81 percent of patients with prostate cancer had skeleton metastasis,when PSA ≥20 μg/L ,60 percent of patients with prostate cancer had skeleton metastasis. Conclusions:The combined detection of radiouclide bone imaging and the serum PSA levels would play an important role in clinical diagnosis of bone metastases for patients with prostate cancer.%目的:研究PSA、SPECT骨显像在前列腺癌诊断及治疗中的临床意义.方法:对100例经临床确诊的前列腺癌患者全部行血清PSA测定及全身骨显像.结果:发生骨转移的患者为81%,PSA≥20 μg/L的患者发生骨转移的为60%.结论:血清PSA与骨显像联检对前列腺癌临床诊断、疗效观察及预后判定具有重要的指导意义.

  17. Radionuclide imaging in the evaluation of osteomyelitis and septic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E.E.; Haynie, T.P.; Podoloff, D.A.; Lowry, P.A.; Harle, T.S. (Univ. of Texas M.D. Anderson Hospital, Houston (USA))

    1989-01-01

    Despite controversy over its exact role, radionuclide imaging plays an important role in the evaluation of patients suspected of having osteomyelitis. The differentiation between osteomyelitis and cellulitis is best accomplished by using a three-phase technique using Tc-99m methylene diphosphonate (MDP). Frequently, it is necessary to obtain multiple projections and magnification views to adequately assess suspected areas. It is recommended that a Ga-67 or In-111 leukocyte scan be performed in those cases where osteomyelitis is strongly suspected clinically and the routine bone scan is equivocal or normal. Repeated bone scan after 48 to 72 h may demonstrate increased radioactivity in the case of early osteomyelitis with the initial photon-deficient lesion. In-111 leukocyte imaging is useful for the evaluation of suspected osteomyelitis complicating recent fracture or operation, but must be used in conjunction with clinical and radiographic correlation. The recognition of certain imaging patterns appears helpful to separate osteomyelitis from septic arthritis or cellulitis. 83 references.

  18. CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis

    Science.gov (United States)

    Obert, Laurent; Peyron, Christelle; Boyer, Etienne; Menu, Gauthier; Loisel, François; Aubry, Sébastien

    2016-01-01

    Introduction: The shoulder arthroplasty brings satisfaction to patients in terms of quality of life and indolence. However whether anatomic implant or reverse, it does not escape from the loosening of the glenoid component. Moreover, optimal implantation is required to ensure the functional outcome without shortening of the arm. The purpose of this study is obtain CT scan evaluation of the glenoid bone stock in order to optimize glenoid component implantation and obtain a reference to determine optimal humeral component placement in case of humeral proximal fracture. Materials and methods: Between 2010 and 2011 we have analyzed 200 intact shoulder’s CT. We measured maximal and minimal width in the transverse plane of the glenoid, the distance from the pectoralis major (PM) tendon to the humeral head, the greater tubercle, change of curvature and the anatomical neck. Results: Mean maximum width was 27.4 ± 3.4 mm and mean minimum width was 15.5 ± 2.8 mm. Distances between upper edge of PM tendon to: humeral head, greater tubercle, change of curvature and anatomical neck were respectively: 67.6 ± 9.98 mm, 57.8 ± 10.3 mm, 28.7 ± 9 mm, and 34.2 ± 9.7 mm. Conclusion: Our study has produced an assessment of glenoid bone stock for optimal positioning of the glenoid implant but also to obtain a reference to determine the ideal location of the humeral component in the case of proximal humerus fracture. PMID:27716461

  19. A Novel Automated Platform for Quantifying the Extent of Skeletal Tumour Involvement in Prostate Cancer Patients Using the Bone Scan Index

    DEFF Research Database (Denmark)

    Ulmert, David; Kaboteh, Reza; Fox, Josef J.

    2012-01-01

    Background There is little consensus on a standard approach to analysing bone scan images. The Bone Scan Index (BSI) is predictive of survival in patients with progressive prostate cancer (PCa), but the popularity of this metric is hampered by the tedium of the manual calculation. Objective Develop...... a fully automated method of quantifying the BSI and determining the clinical value of automated BSI measurements beyond conventional clinical and pathologic features. Design, setting, and participantsWe conditioned a computer-assisted diagnosis system identifying metastatic lesions on a bone scan...... to automatically compute BSI measurements. A training group of 795 bone scans was used in the conditioning process. Independent validation of the method used bone scans obtained ≤3 mo from diagnosis of 384 PCa cases in two large population-based cohorts. An experienced analyser (blinded to case identity, prior BSI...

  20. Comparison of DXA Scans and Conventional X-rays for Spine Morphometry and Bone Age Determination in Children.

    Science.gov (United States)

    Hoyer-Kuhn, Heike; Knoop, Kai; Semler, Oliver; Kuhr, Kathrin; Hellmich, Martin; Schoenau, Eckhard; Koerber, Friederike

    2016-01-01

    Conventional lateral spine and hand radiographs are the standard tools to evaluate vertebral morphometry and bone age in children. Beside bone mineral density analyses, dual-energy X-ray absorptiometry (DXA) measurements with lower radiation exposure provide high-resolution scans which are not approved for diagnostic purposes. Data about the comparability of conventional radiographs and DXA in children are missing yet. The purpose of the trial was to evaluate whether conventional hand and spine radiographs can be replaced by DXA scans to diminish radiation exposure. Thirty-eight children with osteogenesis imperfecta or secondary osteoporosis or short stature (male, n=20; age, 5.0-17.0 yr) were included and assessed once by additional DXA (GE iDXA) of the spine or the left hand. Intraclass correlation coefficients (ICCs) were used to express agreement between X-ray and iDXA assessment. Evaluation of the spine morphometry showed reasonable agreement between iDXA and radiography (ICC for fish-shape, 0.75; for wedge-shape, 0.65; and for compression fractures, 0.70). Bone age determination showed excellent agreement between iDXA and radiography (ICC, 0.97). IDXA-scans of the spine in a pediatric population should be used not only to assess bone mineral density but also to evaluate anatomic structures and vertebral morphometry. Therefore, iDXA can replace some radiographs in children with skeletal diseases.

  1. Follow-up bone scan in breast cancer patients: what is the appropriate interpretation of purely rib uptake?

    Science.gov (United States)

    Seo, Minjung; Ko, Byung Kyun; Tae, Soon Young; Koh, Su-Jin; Noh, Young Ju; Choi, Hye-Jeong; Bae, Kyungkyg; Bang, Minseo; Jun, Sungmin; Park, Seol Hoon

    2016-12-01

    Although rib uptake is frequently detected in follow-up bone scans of breast cancer patients, few studies have assessed its clinical significance. Among 1208 breast cancer patients who underwent a bone scan between 2011 and 2014, 157 patients presented with newly detected rib uptake at follow-up. Patients who had underlying bone metastases (n=8) or had simultaneous new uptake in sites other than the rib (n=13) were excluded. The patients enrolled finally were those who had purely rib uptakes. The location, intensity, and final diagnosis of the uptake were evaluated by nuclear medicine physicians. A total of 275 new instances of rib uptake were detected in follow-up bone scans of 136 patients. These were more frequently located on the ipsilateral side of the breast cancer (61.1%) and the anterior arc (65.1%), and they presented as moderate to intense (93.1%) uptakes. Among these, 265 lesions in 130 patients turned out to be benign fractures (96.4%), whereas only 10 lesions in six patients were metastases. The proportion of metastases was significantly higher if the uptake was linear or if the patient had recurrence. It was marginally higher if the uptake was located in the posterior arc. The proportion of metastases within the radiation field was significantly lower in patients with a history of irradiation. Newly detected purely rib uptake on a follow-up bone scan in patients who have been treated for breast cancer is mostly because of fractures and rarely signals metastasis. However, if the patient has disease recurrence, metastasis should strongly be suspected, particularly when uptake is linear or located in the posterior arc.

  2. Investigation of the vestibular aqueduct and the cochlear aqueduct by temporal bone CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Ryuichi; Kamei, Tamio; Ito, Fumihide (Gunma Univ., Maebashi (Japan). School of Medicine)

    1984-02-01

    The visualization of the vestibular aqueduct and the cochlear aqueduct was investigated by temporal bone CT scan. The vestibular aqueduct was visualized in horizontal CT sections of 70.0% of normal ears, 61.5% of ears with chronic otitis media, 58.3% of ears with combined hearing impairment, 66.7% of ears in cases of sudden deafness, 70.8% of ears of patients with sensorineural hearing impairment without sudden deafness, 71.4% of cases of vertigo without hearing impairment and 12.5% of both diseased and contralateral ears of patients with Meniere's disease. Only in Meniere's disease was the vestibular aqueduct less visible in the diseased than in the normal ear (P<0.01). The cochlear aqueduct was visible in coronal sections of 50.0% of normal ears, 76.9% of those with chronic otitis media, 58.3% of those with combined hearing impairment, 66.7% of those with sudden deafness 41.7% of those with sensorineural hearing impairment without sudden deafness, 50.0% of the diseased ears of patients with Meniere's disease, 37.5% of the contralateral ears of those with Meniere's disease and 64.3% of those with vertigo without hearing impairment. Although the cochlear aqueduct was thus highly demonstrable in patients with chronic otitis media or sudden deafness, the difference between the percentage of visualization in these diseased and in normal ears was not statistically significant.

  3. Detection of bone metastases in breast cancer patients in the PET/CT era: Do we still need the bone scan?

    Science.gov (United States)

    Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F

    2016-01-01

    To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  4. A simple way to distinguish bed clothing contamination in a whole body bone scan: a case report

    Directory of Open Access Journals (Sweden)

    Assadi Majid

    2007-12-01

    Full Text Available Abstract Whole body bone scan with Technetium-99m MDP (methylene diphosphate can detect bony lesions due to altered osteoblastic activity. Non-physiologic or increased radiotracer uptake in the bony structures of patients with a history of malignant diseases is usually interpreted as being suspicious of bone metastasis. It is extremely important to properly distinguish false positive sites of Tc-99m MDP localization. We present three patients with the same pattern of Tc-99m MDP abnormality in different locations. These scans were all performed on the same day to evaluate possible bone metastases in three patients with breast carcinoma. After careful examination, repeated images revealed bed clothing contamination. This is different from bed contamination by displacement among different patients. It is also different from detector contamination by limited area of involvement where detector contamination appears as a line throughout the total body projection. It can be helpful if a nuclear medicine specialist has a brief look at all scans prior to reporting them. In cases where the same pattern of abnormality is repeated in all images, the possibility of technical error such as bed clothing contamination rather than a pathological abnormality should be borne in mind.

  5. Assessment of the absorbed dose to organs from bone mineral density scan by using TLDS and the Monte Carlo method

    Directory of Open Access Journals (Sweden)

    Karimian Alireza

    2014-01-01

    Full Text Available Nowadays, dual energy X-ray absorptiometry is used in bone mineral density systems to assess the amount of osteoporosis. The purpose of this research is to evaluate patient organ doses from dual X-ray absorptiometry by thermoluminescence dosimeters chips and Monte Carlo method. To achieve this goal, in the first step, the surface dose of the cervix, kidney, abdomen region, and thyroid were measured by using TLD-GR 200 at various organ locations. Then, to evaluate the absorbed dose by simulation, the BMD system, patient's body, X-ray source and radiosensitive tissues were simulated by the Monte Carlo method. The results showed, for the spine (left femur bone mineral density scan by using thermoluminescence dosimeters, the absorbed doses of the cervix and kidney were 4.5 (5.64 and 162.17 (3.99(mGy, respectively. For spine (left femur bone mineral density scan in simulation, the absorbed doses of the cervix and kidney were 4.19 (5.88 and 175 (3.68(mGy, respectively. The data obtained showed that the absorbed dose of the kidney in the spine scan is noticeable. Furthermore, because of the small relative difference between the simulation and experimental results, the radiation absorbed dose may be assessed by simulation and software, especially for internal organs, and at different depths of otherwise inaccessible organs which is not possible in experiments.

  6. Dosimetry of bone metastases in targeted radionuclide therapy with alpha-emitting {sup 223}Ra-dichloride

    Energy Technology Data Exchange (ETDEWEB)

    Pacilio, Massimiliano [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Medical Physics; Ventroni, Guido; Mango, Lucio [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Nuclear Medicin; De Vincentis, Giuseppe; Di Castro, Elisabetta; Frantellizzi, Viviana; Follacchio, Giulia Anna; Garkavaya, Tatiana [Rome Univ. (Italy). Dept. of Radiological, Oncological and Anatomo Pathological Sciences; Cassano, Bartolomeo; Lorenzon, Leda [Rome Univ. (Italy). Postgraduate School of Medical Physics; Pellegrini, Rosanna; Pani, Roberto [Rome Univ. (Italy). Dept. of Molecular Medicine; Ialongo, Pasquale [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Radiology

    2016-01-15

    Ra-dichloride is an alpha-emitting radiopharmaceutical used in the treatment of bone metastases from castration-resistant prostate cancer. Image-based dosimetric studies remain challenging because the emitted photons are few. The aim of this study was to implement a methodology for in-vivo quantitative planar imaging, and to assess the absorbed dose to lesions using the MIRD approach. The study included nine Caucasian patients with 24 lesions (6 humeral head lesions, 4 iliac wing lesions, 2 scapular lesions, 5 trochanter lesions, 3 vertebral lesions, 3 glenoid lesions, 1 coxofemoral lesion). The treatment consisted of six injections (one every 4 weeks) of 50 kBq per kg body weight. Gamma-camera calibrations for {sup 223}Ra included measurements of sensitivity and transmission curves. Patients were statically imaged for 30 min, using an MEGP collimator, double-peak acquisition, and filtering to improve the image quality. Lesions were delineated on {sup 99m}Tc-MDP whole-body images, and the ROIs superimposed on the {sup 223}Ra images after image coregistration. The activity was quantified with background, attenuation, and scatter correction. Absorbed doses were assessed deriving the S values from the S factors for soft-tissue spheres of OLINDA/EXM, evaluating the lesion volumes by delineation on the CT images. In 12 lesions with a wash-in phase the biokinetics were assumed to be biexponential, and to be monoexponential in the remainder. The optimal timing for serial acquisitions was between 1 and 5 h, between 18 and 24 h, between 48 and 60 h, and between 7 and 15 days. The error in cumulated activity neglecting the wash-in phase was between 2 % and 12 %. The mean effective half-life (T{sub 1/2eff}) of {sup 223}Ra was 8.2 days (range 5.5-11.4 days). The absorbed dose (D) after the first injection was 0.7 Gy (range 0.2-1.9 Gy). Considering the relative biological effectiveness (RBE) of alpha particles (RBE = 5), D{sub RBE} = 899 mGy/MBq (range 340-2,450 mGy/MBq). The

  7. [The diagnostic value of 99mTc-MDP bone scan and computed tomography for bone metastases of breast cancer: a systematic review].

    Science.gov (United States)

    Yu, Yanxia; Kuang, Anren

    2014-06-01

    According to the inclusion and exclusion criteria, we searched for relevant original articles in some big Chinese and English databases. The qualities of the studies were evaluated with QUADAS quality assessment tool. A software program, Meta-disc, was used to obtain the pooled estimates and heterogeneity test for sensitivity, specificity, SROC curve, and so on. Finally the 17 article were included. On a per-patient basis, the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (LR+), negative likelihood ratio (LR-), diagnostic odds ratio (DOR), Q*, SROC area under curve for 99mTc-MDP bone scan and computed tomography (CT) were 0. 87 and 0.99, 0.81 and 0.98, 3.88 and 13.86, 0.2 and 0.03, 27.73 and 612.17, 0.8418 and 0.9732, 0.9097 and 0.9952, respectively. On a per-focus basis, the pooled SEN, SPE, LR+, LR-, DOR, Q*, SROC area under curve for 99mTc-MDP bone scan was 0.86, 0.97, 13.32, 0.16, 102.4, 0.8944, 0.9528, respectively. For CT, only 1 article were included. This paper demonstrate: whether 99mTc-MDP or CT both have high diagnostic efficiency for bone metastase of breast cancer.

  8. Prostate cancer in patients from rural and suburban areas – PSA value, Gleason score and presence of metastases in bone scan

    Directory of Open Access Journals (Sweden)

    Wojciech Szot

    2014-11-01

    Full Text Available [b]Introduction[/b]. Prostate cancer is the second most common neoplasm among men both worldwide and in Poland. In prostate cancer, bone metastasis is related to a poorer prognosis. A diagnosis of metastatic bone disease is important in prostate cancer patients prior to therapy. Prostate specific antigen (PSA serum value is used both as a screening tool and for staging of prostate cancer. aim. To evaluate whether there is a link between symptoms presented by patients, pain in particular, and the presence, number and location of bone metastases as assessed by bone scan scintigraphy in concordance with PSA values and Gleason scores. [b]material[/b]. A group of 186 patients (aged: 68.38±6.16 diagnosed with prostate cancer, from rural and suburban areas of Małopolska province, that was directed for bone scan scintigraphy to the Nuclear Medicine Dept, John Paul II Hospital in Kraków. [b]methods[/b]. Analysis of all laboratory findings (including PSA value and a biopsy were performed. Then, bone scan scintigraphy was done with the use of methylene disphosphonate (MDP labeled with Tc-99m. [b]results[/b]. In patients with a Gleason value ≤7 and a PSA value ≤20 ng/ml, the cutoff value for a negative bone scan with a confidence interval of 0.95 was established at a PSA value below 10 ng/ml (p<0.01. Correlations were established between PSA value and presence of metastases in bone scan (r=0.45, p=0.05, the number of metastases (r=0.66, p<0.01, and their presence in particular body regions. [b]conclusions[/b]. The correlation between PSA value and both presence and number of metastases confirms the usefulness of bone scan scintigraphy in prostate cancer staging. The cutoff value for negative bone scan with a 95% confidence interval was established at PSA = 10 ng/ml.

  9. Template-based automatic extraction of the joint space of foot bones from CT scan

    Science.gov (United States)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  10. Value of bone scan in the McCune-Albright syndrome. Report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Edeburn, G.F.; Mortensson, W.

    Bone scintigraphy proved valuable in diagnosing McCune-Albright's syndrome in a 6-year-old girl by detecting multiple, non-symptomatic foci in the skull, axial skeleton and in the extremities. Subsequent roentgen examination showed abnormal bone structure in the affected areas, consistent with fibrous dysplasia.

  11. Comparison of macroscopic and microscopic (stereomicroscopy and scanning electron microscopy) features of bone lesions due to hatchet hacking trauma.

    Science.gov (United States)

    Nogueira, Luísa; Quatrehomme, Gérald; Bertrand, Marie-France; Rallon, Christophe; Ceinos, Romain; du Jardin, Philippe; Adalian, Pascal; Alunni, Véronique

    2017-03-01

    This experimental study examined the lesions produced by a hatchet on human bones (tibiae). A total of 30 lesions were produced and examined macroscopically (naked eye) and by stereomicroscopy. 13 of them were also analyzed using scanning electron microscopy. The general shape of the lesion, both edges, both walls, the kerf floor and the extremities were described. The length and maximum width of the lesions were also recorded. The microscopic analysis of the lesions led to the description of a sharp-blunt mechanism. Specific criteria were identified (lateral pushing back, fragmentation of the upraising, fossa dug laterally to the edge and vertical striae) enabling the forensic expert to conclude that a hacking instrument was used. These criteria are easily identifiable using scanning electron microscopy, but can also be observed with stereomicroscopy. Overall, lateral pushing back and vertical striae visible using stereomicroscopy and scanning electron microscopy signal the use of a hacking tool.

  12. Comparative study on measured variables and sensitivity to bone microstructural changes induced by weightlessness between in vivo and ex vivo micro-CT scans.

    Science.gov (United States)

    Sun, Lian Wen; Wang, Chao; Pu, Fang; Li, De Yu; Niu, Hai Jun; Fan, Yu Bo

    2011-01-01

    Depending on the experimental design, micro-CT can be used to examine bones either in vivo or ex vivo (excised fresh or formalin-fixed). In this study we investigated if differences exist in the variables measured by micro-CT between in vivo and ex vivo scans and which kind of scan is more sensitive to the changes of bone microstructure induced by simulated weightlessness. Rat tail suspension was used to simulate the weightless condition. The same bone from either normal or tail-suspended rats was scanned by micro-CT both in vivo and ex vivo (fresh and fixed by formalin). Then, bone mineral density (BMD) and microstructural characteristics were analyzed. The results showed that no significant differences existed in the microstructural parameters of trabecular bone among in vivo, fresh, and formalin-fixed bone scans from both femurs and tibias, although BMD exhibited differences. On the other hand, most parameters of the tail-suspended rats measured by micro-CT deteriorated compared with controls. Ex vivo scanning appeared to be more sensitive to bone microstructural changes induced by tail suspension than in vivo scanning. In general, the results indicate that values obtained in vivo and ex vivo (fresh and fixed) are comparable, thus allowing for meaningful comparison of experimental results from different studies irrespective of the type of scans. In addition, this study suggests that it is better to use ex vivo scanning when evaluating bone microstructure under weightlessness. However, researchers can select any type of scan depending upon the objective and the demands of the experiment.

  13. The relationship between skeletal-related events and bone scan index for the treatment of bone metastasis with breast cancer patients.

    Science.gov (United States)

    Iwase, Toshiaki; Yamamoto, Naohito; Ichihara, Hironori; Togawa, Takashi; Nagashima, Takeshi; Miyazaki, Masaru

    2014-12-01

    The aim of the present study was to investigate the relationships between the automated bone scan index (aBSI) and skeletal-related events (SRE) in breast cancer patients with bone metastasis. A computer-aided software (BONENAVI™) that was developed using an Artificial Neural Network (Artificial Neural Network) was used for the present analysis. Forty-five patients diagnosed with bone metastasis due to breast cancer from April 2005 through March 2013 were retrospectively analyzed. Before and after the time of initial treatment, aBSI, Artificial Neural Network score, and hotspot number were calculated, and the relationships between these scores and SRE were analyzed. Twenty cases showed decreased (improved) aBSI values after initial treatment (Group A), and 25 cases showed unchanged/increased (worsened) aBSI values (Group B). Chi-square analysis revealed a significant difference in incident numbers of SRE between the two groups--one case in Group A and 12 in Group B (Pbone metabolic or tumor markers, alkaline phosphatase was significantly correlated with aBSI at the time of initial treatment (R=0.69, Pcancer patients with bone metastasis at high risk of SRE.

  14. Colon visualization on (99m)Tc-HDP whole-body bone scan due to sigmoid colon cancer-related enterovesical fistula.

    Science.gov (United States)

    Kim, Sung Hoon; Song, Bong-Il; Won, Kyoung Sook

    2015-01-01

    An abnormally increased uptake of the bone-seeking agent is rarely observed in structures other than the bone and urinary track on bone scintigraphy. The general etiologies of soft tissue uptake can be explained by heterotopic ossification or dystrophic and metastatic calcification. We report a case of serendipitous visualization of the entire colon on bone scintigraphy. Diffuse colonic uptake was detected on the whole-body bone scan in a patient with biopsy-proven sigmoid colon cancer. Additional imaging studies clearly showed direct bladder invasion of the sigmoid colon cancer. Imaging findings with a brief review of the literature are presented in this article.

  15. Atypical bisphosphonate-associated subtrochanteric and femoral shaft stress fractures: diagnostic features on bone scan.

    Science.gov (United States)

    Probst, Stephan; Rakheja, Rajan; Stern, Jerry

    2013-05-01

    A 69-year-old woman presented with a spontaneous right subtrochanteric hip fracture. Pan-imaging following orthopedic repair failed to identify a primary malignancy to explain the presumed pathologic basis for this fracture. The patient then underwent bone scintigraphy and SPECT/CT which showed mild uptake in multifocal endosteal thickening of the lateral left femoral diaphysis, diagnostic of bisphosphonate-associated femoral shaft stress fractures, but no evidence of metastatic bone disease. Atypical bisphosphonate-associated subtrochanteric and femoral shaft stress fractures have a fairly specific appearance on bone scintigraphy, and nuclear medicine physicians should be aware of this relatively infrequent emerging pathology.

  16. A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Yonekawa, Hiroyuki; Ohashi, Masami; Miyashita, Souji; Gotoh, Mizuho; Nemoto, Satohiko; Kikuchi, Hideki (Azabu Triology Hospital, Sapporo (Japan)); Sakai, Noboru; Inuyama, Yukio

    1993-09-01

    The current availability of 3 dimensional (3-D) imaging from Computed Tomography (CT) has yielded new anatomical information and pre- and postoperative evaluations. However, little discussion as to the 3-D structural image of the temporal bone has been reported because conventional CT does provide sufficient data to produce such images. The helical scanning CT gathers continuous and multiple slice image data since it consists of an X-ray tube that continuously rotates around the patient while the patient moves continuously into the CT scanner. Thus, application of the helical scanning CT has made it possible to reconstruct 3-D images of the minute and complicated structure of the temporal bone. We evaluated 3-D images from 9 typical cases, examined from February to October 1992. As a result, we found that the 3-D images reconstructed with this system are useful for evaluation of the postoperative state of tympanoplasty, the diagnosis of anomalies of the bony labyrinth, and examining the extent of bone destruction induced by trauma, cholesteatoma, etc. (author).

  17. Which metabolic imaging, besides bone scan with 99mTc-phosphonates, for detecting and evaluating bone metastases in prostatic cancer patients? An open discussion.

    Science.gov (United States)

    Bombardieri, E; Setti, L; Kirienko, M; Antunovic, L; Guglielmo, P; Ciocia, G

    2015-12-01

    Prostate cancer bone metastases occur frequently in advanced cancer and this is matter of particular attention, due to the great impact on patient's management and considering that a lot of new emerging therapeutic options have been recently introduced. Imaging bone metastases is essential to localize lesions, to establish their size and number, to study characteristics and changes during therapy. Besides radiological imaging, nuclear medicine modalities can image their features and offer additional information about their metabolic behaviour. They can be classified according to physical characteristics, type of detection, mechanism of uptake, availability for daily use. The physiopathology of metastases formation and the mechanisms of tracer uptake are essential to understand the interpretation of nuclear medicine images. Therefore, radiopharmaceuticals for bone metastases can be classified in agents targeting bone (99mTc-phosphonates, 18F-fluoride) and those targeting prostatic cancer cells (18F-fluoromethylcholine, 11C-choline, 18F-fluorodeoxyglucose). The modalities using the first group of tracers are planar bone scan, SPECT or SPECT/CT with 99mTc-diphosphonates, and 18F-fluoride PET/CT, while the modalities using the second group include 18F/11C-choline derivatives PET/CT, 18F-FDG PET/CT and PET/CT scans with several other radiopharmaceuticals described in the literature, such as 18F/11C-acetate derivatives, 18F-fluoro-5α-dihydrotestosterone (FDHT), 18F-anti-1-amino-3-fluorocyclobutane-1-carboxylic acid (FACBC), 18F-2'-fluoro-5-methyl-1-β-D-arabinofuranosyluracil (FMAU) and 68Ga-labeled-prostate specific membrane antigen (PMSA) PET/TC. However, since data on clinical validation for these last novel modalities are not conclusive and/or are not still sufficient in number, at present they can be still considered as promising tools under evaluation. The present paper considers the nuclear modalities today available for the clinical routine. This overview wants

  18. Three-dimensional CT imaging with a helical scan on temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Sakakura, Atsushi; Yoshikawa, Shuji; Shimizu, Takaya; Sueyoshi, Kozo; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1996-06-01

    To evaluate the usefulness of three-dimensional (3D) CT on the lesions of temporal bone, we studied 19 patients with disorders on the region of temporal bone by high speed helical CT. The results showed that 8 patients with congenital hearing disorder had deficiency of the auditory ossicles, 2 patients with chronic otitis media had deformity and shortness of the auditory ossicles, 4 patients with trauma had fracture of the temporal bone (1 patient was complicated by doubtful fracture of the incus), 5 patients (4 patients with acquired hearing disorder and 1 patient with otorrhea) had space-occupying lesions. 3-D helical CT could detect abnormal findings on all the patients and it was an important examination for the temporal bone. (author)

  19. Development of a nomogram model predicting current bone scan positivity in patients treated with androgen-deprivation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Michael eKattan

    2014-10-01

    Full Text Available Purpose: To develop a nomogram predictive of current bone scan positivity in patients receiving androgen-deprivation therapy (ADT for advanced prostate cancer; to augment clinical judgment and highlight patients in need of additional imaging investigations.Materials and Methods: A retrospective chart review of bone scan records (conventional 99mTc-scintigraphy of 1,293 patients who received ADT at the Memorial Sloan-Kettering Cancer Center from 2000 to 2011. Multivariable logistic regression analysis was used to identify variables suitable for inclusion in the nomogram. The probability of current bone scan positivity was determined using these variables and the predictive accuracy of the nomogram was quantified by concordance index.Results: In total, 2,681 bone scan records were analyzed and 636 patients had a positive result. Overall, the median pre-scan prostate-specific antigen (PSA level was 2.4 ng/ml; median PSA doubling time (PSADT was 5.8 months. At the time of a positive scan, median PSA level was 8.2 ng/ml; 53% of patients had PSA <10 ng/ml; median PSADT was 4.0 months. Five variables were included in the nomogram: number of previous negative bone scans after initiating ADT, PSA level, Gleason grade sum, and history of radical prostatectomy and radiotherapy. A concordance index value of 0.721 was calculated for the nomogram. This was a retrospective study based on limited data in patients treated in a large cancer centre who underwent conventional 99mTc bone scans, which themselves have inherent limitations. Conclusions: This is the first nomogram to predict current bone scan positivity in ADT-treated prostate cancer patients, providing high predictive accuracy.

  20. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans,

  1. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, a

  2. Radionuclide transfer. Radionuklid Transfer

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, G.B.

    1993-01-01

    The research project described here had the aim to obtain further information on the transfer of nuclides during pregnancy and lactation. The tests were carried out in mini-pigs and rats receiving unchanging doses of radionuclides with the food. The following findings were revealed for the elements examined: Fe, Se, Cs and Zn were characterized by very high transfer levels in the mother, infant and foetus. A substantial uptake by the mother alone was observed for Co, Ag and Mn. The uptake by the foetus and infant here was 1 to 10 times lower. A preferential concentration in certain tissues was seen for Sr and Tc; the thyroid levels of Tc were about equally high in mothers and infants, while Sr showed less accumulation in the maternal bone. The lanthanide group of substances (Ce, Eu and Gd as well as Y and Ru) were only taken up to a very limited extent. The uptake of the examined radionuclides (Fe, Co, Ag, Ce) with the food ingested was found here to be ten times greater in rats as compared to mini-pigs. This showed that great caution must be observed, if the behaviour of radionuclides in man is extrapolated from relevant data obtained in rodents. (orig./MG)

  3. Hypertrophic osteoarthropathy as the cause of a super scan of the bone in a patient with prostate cancer: a case report

    Directory of Open Access Journals (Sweden)

    Kanen Boris L

    2008-04-01

    Full Text Available Abstract Introduction Prostate cancer is known to have a tendency to metastasize to bone. Skeletal scintigraphy can be used to show multiple lesions. Diffuse metastasis, which is not infrequent in prostate cancer, can also be suspected on the basis of a 'super scan'. However, this phenomenon in nuclear medicine has several other causes that need to be considered. Case presentation A patient with a history of prostate cancer presented with pleural fluid, peripheral edema and bone pain. A super scan of the bone was found which suggested diffuse skeletal metastasis of the prostate cancer but the patient also had a prostate specific antigen level which was not compatible with this diagnosis. Further investigations revealed the paraneoplastic phenomenon of hypertrophic osteoarthropathy, related to an incurable carcinoma of the lung, to be the cause of the super scan. Conclusion A super scan is characterized by a high bone to soft tissue ratio on skeletal scintigraphy, with a uniform symmetrical increase in bone uptake and diminished to absent renal visualization ('absent kidney sign'. It can be seen in a variety of diseases in which there is a diffusely increased bone turnover. Diffuse skeletal metastasis of a well-differentiated prostate carcinoma is unlikely to be the cause of a super scan when the prostate specific antigen level is not elevated. This is the first report of a super scan due to pulmonary hypertrophic osteoarthropathy which can be seen in lung carcinoma and other pulmonary diseases.

  4. Non-invasive assessment of bone quantity and quality in human trabeculae using scanning ultrasound imaging

    Science.gov (United States)

    Xia, Yi

    Fractures and associated bone fragility induced by osteoporosis and osteopenia are widespread health threat to current society. Early detection of fracture risk associated with bone quantity and quality is important for both the prevention and treatment of osteoporosis and consequent complications. Quantitative ultrasound (QUS) is an engineering technology for monitoring bone quantity and quality of humans on earth and astronauts subjected to long duration microgravity. Factors currently limiting the acceptance of QUS technology involve precision, accuracy, single index and standardization. The objective of this study was to improve the accuracy and precision of an image-based QUS technique for non-invasive evaluation of trabecular bone quantity and quality by developing new techniques and understanding ultrasound/tissue interaction. Several new techniques have been developed in this dissertation study, including the automatic identification of irregular region of interest (iROI) in bone, surface topology mapping (STM) and mean scattering spacing (MSS) estimation for evaluating trabecular bone structure. In vitro results have shown that (1) the inter- and intra-observer errors in QUS measurement were reduced two to five fold by iROI compared to previous results; (2) the accuracy of QUS parameter, e.g., ultrasound velocity (UV) through bone, was improved 16% by STM; and (3) the averaged trabecular spacing can be estimated by MSS technique (r2=0.72, p<0.01). The measurement errors of BUA and UV introduced by the soft tissue and cortical shells in vivo can be quantified by developed foot model and simplified cortical-trabecular-cortical sandwich model, which were verified by the experimental results. The mechanisms of the errors induced by the cortical and soft tissues were revealed by the model. With developed new techniques and understanding of sound-tissue interaction, in vivo clinical trail and bed rest study were preformed to evaluate the performance of QUS in

  5. The Diagnostic Value of Observation of Early Lung Cancer Bone Metastasis by Tumor Markers and Radionuclide Bone Imaging%肿瘤标志物检测和核素骨显像对肺癌早期骨转移的诊断价值观察

    Institute of Scientific and Technical Information of China (English)

    殷健

    2013-01-01

    Objective To approach diagnostic result of early lung cancer bone metastasis by tumor markers and radionuclide bone imaging. Method Analyzed 50 cases clinical data of lung cancer patients from May 2010 to May 2013 in our hospital department of radiology, selected 50 cases in our hospital during the same period in healthy volunteers was control group. Result The CEA, CYFR21-1, NSE detection result of radionuclide bone imaging positive group of lung cancer patients were higher than control group and radionuclide bone imaging, CEA, CYFR21-1, NSE positive incidence of of lung cancer patients were higher than control group and radionuclide bone imaging,P<0.05, the difference were statistical significance. Conclusion The staging and treatment methods to determine clinical judgment detection of serum tumor markers and radionuclide bone imaging for early lung cancer bone metastasis were significance.%目的:探讨肿瘤标志物检测和核素骨显像对肺癌早期骨转移的诊断效果。方法分析2010年5月至2013年5月影像科诊断的肺癌患者50例临床资料,选取同期我院健康体检者50例作为对照组。结果核素骨显像阳性组肺癌患者CEA、CYFR21-1、NSE检测结果均高于对照组和核素骨显像阳性组,核素骨显像阳性组肺癌患者CEA、CYFR21-1、NSE阳性率均高于对照组和核素骨显像阳性组, P<0.05,差异均有统计学意义。结论肿瘤标志物检测和核素骨显像对于肺癌早期骨转移的临床判断、分期和确定治疗方法具有重要意义。

  6. Biomechanical Role of Bone Anisotropy Estimated on Clinical CT Scans by Image Registration.

    Science.gov (United States)

    Taghizadeh, Elham; Reyes, Mauricio; Zysset, Philippe; Latypova, Adeliya; Terrier, Alexandre; Büchler, Philippe

    2016-08-01

    Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

  7. Bone marrow trephine biopsy in Hodgkin's lymphoma. Comparison with PET-CT scan in 65 patients.

    Science.gov (United States)

    Lakhwani, Sunil; Cabello-García, Dolores; Allende-Riera, Ana; Cárdenas-Negro, Carlos; Raya, José María; Hernández-Garcia, Miguel T

    2017-08-29

    To compare bone marrow biopsy (BMB) and PET/CT in detecting bone marrow involvement in Hodgkin's lymphoma MATERIAL AND METHODS: Retrospective analysis of 65 patients with both tests in the initial staging or in relapse with special attention to the PET/CT uptake pattern. In 3 patients (4.6%), the BMB showed bone marrow involvement with the PET/CT being positive in them all: 2 with diffuse+multifocal pattern and one diffuse only. In 11 additional patients (total 14/65, 21%), bone marrow involvement was diagnosed by PET/CT because bone marrow uptake was above hepatic one. The pattern was focal only in 2 cases, multifocal in 5, diffuse in 3 and diffuse+multifocal in one. In these last 4 cases the BMB showed an unspecific myelopathy. PET/CT detects all cases with BMB affected and many that escape to biopsy, however when the uptake pattern is diffuse it could be by involvement or reactive hyperplasia and in those cases the BMB should be done. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  8. Role of (99m)Tc-MDP bone scan in the diagnosis of Erdheim-Chester disease.

    Science.gov (United States)

    Mukherjee, Anirban; Damle, Nishikant; Bal, Chandrasekhar; Arora, Arundeep; Singhal, Abhinav; Tripathi, Madhavi; Peepre, Karan

    2014-07-01

    Erdheim-Chester disease (ECD) is a rare systemic non-Langerhans cell histiocytosis. It is a progressive disease of unknown etiology. The (99m)technetium-methylene diphosphonate ((99m)Tc-MDP) bone scan is useful in finding the sites of involvement in the skeleton and is helpful in excluding other causes of bony pain. Also a scintigraphic pattern consistent with ECD should alert the physician to evaluate the patient for visceral sites of involvement using fludeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), as this is known to be fatal at times.

  9. Semiautomated three-dimensional segmentation software to quantify carpal bone volume changes on wrist CT scans for arthritis assessment.

    Science.gov (United States)

    Duryea, J; Magalnick, M; Alli, S; Yao, L; Wilson, M; Goldbach-Mansky, R

    2008-06-01

    Rapid progression of joint destruction is an indication of poor prognosis in patients with rheumatoid arthritis. Computed tomography (CT) has the potential to serve as a gold standard for joint imaging since it provides high resolution three-dimensional (3D) images of bone structure. The authors have developed a method to quantify erosion volume changes on wrist CT scans. In this article they present a description and validation of the methodology using multiple scans of a hand phantom and five human subjects. An anthropomorphic hand phantom was imaged with a clinical CT scanner at three different orientations separated by a 30-deg angle. A reader used the semiautomated software tool to segment the individual carpal bones of each CT scan. Reproducibility was measured as the root-mean-square standard deviation (RMMSD) and coefficient of variation (CoV) between multiple measurements of the carpal volumes. Longitudinal erosion progression was studied by inserting simulated erosions in a paired second scan. The change in simulated erosion size was calculated by performing 3D image registration and measuring the volume difference between scans in a region adjacent to the simulated erosion. The RMSSD for the total carpal volumes was 21.0 mm3 (CoV = 1.3%) for the phantom, and 44.1 mm3 (CoV = 3.0%) for the in vivo subjects. Using 3D registration and local volume difference calculations, the RMMSD was 1.0-3.0 mm3 The reader time was approximately 5 min per carpal bone. There was excellent agreement between the measured and simulated erosion volumes. The effect of a poorly measured volume for a single erosion is mitigated by the large number of subjects that would comprise a clinical study and that there will be many erosions measured per patient. CT promises to be a quantifiable tool to measure erosion volumes and may serve as a gold standard that can be used in the validation of other modalities such as magnetic resonance imaging.

  10. Diffuse pulmonary ossification detected by bone scanning with Tc-99m hydroxymethylene diphosphate

    Energy Technology Data Exchange (ETDEWEB)

    Saks, D.A.; McClees, E.C.; Fajman, W.A.; Hollinger, W.M.; Gilman, M.J.

    1984-10-01

    Diffuse pulmonary ossification (DPO) is a rare pathologic finding of heterotropic bone formation within the lungs. It has been associated with mitral stenosis, chronic left ventricular failure, interstitial fibrosis, metastatic breast cancer, pulmonary amyloidosis, histoplasmosis, and chronic busulfan therapy. This patient represents a case associated with Placidyl use.

  11. Evaluation of /sup 99m/Tc diphosphonate kinetics and bone scans in patients with Paget's disease before and after calcitonin treatment

    Energy Technology Data Exchange (ETDEWEB)

    Waxman, A.D.; Ducker, S.; McKee, D.; Siemsen, J.K.; Singer, F.R.

    1977-12-01

    Eleven patients with Paget's disease of bone underwent serial total body bone scans before and after therapy with calcitonin. All patients studied showed improvement clinically as well as biochemically. Scan improvement was noted in patients with mild disease. Patients with severe disease showed either no change or only slight improvement on the serial bone scans. The scan was of greatest value in determining the extent of disease, especially in 3 patients in whom biochemical values were normal. A single pulse injection of 50 M.R.C. units of salmon calcitonin produced a significant increase in the blood clearance of /sup 99m/Tc diphosphonate. The mechanism of this effect is not clear from this study.

  12. Quantifying migration and polarization of murine mesenchymal stem cells on different bone substitutes by confocal laser scanning microscopy.

    Science.gov (United States)

    Roldán, J C; Chang, E; Kelantan, M; Jazayeri, L; Deisinger, U; Detsch, R; Reichert, T E; Gurtner, G C

    2010-12-01

    Cell migration is preceded by cell polarization. The aim of the present study was to evaluate the impact of the geometry of different bone substitutes on cell morphology and chemical responses in vitro. Cell polarization and migration were monitored temporally by using confocal laser scanning microscopy (CLSM) to follow green fluorescent protein (GFP)±mesenchymal stem cells (MSCs) on anorganic cancellous bovine bone (Bio-Oss(®)), β-tricalcium phosphate (β-TCP) (chronOS(®)) and highly porous calcium phosphate ceramics (Friedrich-Baur-Research-Institute for Biomaterials, Germany). Differentiation GFP±MSCs was observed using pro-angiogenic and pro-osteogenic biomarkers. At the third day of culture polarized vs. non-polarized cellular sub-populations were clearly established. Biomaterials that showed more than 40% of polarized cells at the 3rd day of culture, subsequently showed an enhanced cell migration compared to biomaterials, where non-polarized cells predominated (pculture (pculture (p=0.001). This model opens an interesting approach to understand osteoconductivity at a cellular level. MSCs are promising in bone tissue engineering considering the strong angiogenic effect before differentiation occurs. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Astronaut Bone Medical Standards Derived from Finite Element (FE) Models of QCT Scans from Population Studies

    Science.gov (United States)

    Sibonga, J. D.; Feiveson, A. H.

    2014-01-01

    This work was accomplished in support of the Finite Element [FE] Strength Task Group, NASA Johnson Space Center [JSC], Houston, TX. This group was charged with the task of developing rules for using finite-element [FE] bone-strength measures to construct operating bands for bone health that are relevant to astronauts following exposure to spaceflight. FE modeling is a computational tool used by engineers to estimate the failure loads of complex structures. Recently, some engineers have used this tool to characterize the failure loads of the hip in population studies that also monitored fracture outcomes. A Directed Research Task was authorized in July, 2012 to investigate FE data from these population studies to derive these proposed standards of bone health as a function of age and gender. The proposed standards make use of an FE-based index that integrates multiple contributors to bone strength, an expanded evaluation that is critical after an astronaut is exposed to spaceflight. The current index of bone health used by NASA is the measurement of areal BMD. There was a concern voiced by a research and clinical advisory panel that the sole use of areal BMD would be insufficient to fully evaluate the effects of spaceflight on the hip. Hence, NASA may not have a full understanding of fracture risk, both during and after a mission, and may be poorly estimating in-flight countermeasure efficacy. The FE Strength Task Group - composed of principal investigators of the aforementioned population studies and of FE modelers -donated some of its population QCT data to estimate of hip bone strength by FE modeling for this specific purpose. Consequently, Human Health Countermeasures [HHC] has compiled a dataset of FE hip strengths, generated by a single FE modeling approach, from human subjects (approx.1060) with ages covering the age range of the astronauts. The dataset has been analyzed to generate a set of FE strength cutoffs for the following scenarios: a) Qualify an

  14. Bone and gallium scan findings in malignant fibrous histiocytoma. Case report with radiographic and pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Mackey, J.K.; Alexieva-Jackson, B.; Fetters, D.V.; Edwards, S.M.; McBride, J.P.; Cole, R.L.; Trapp, W.G.

    1987-01-01

    Malignant fibrous histiocytoma (MFH) is the most common soft tissue malignancy in adults. The Ga-67 citrate scan findings of an extremity-located MFH, the most common location of this neoplasm, have never been published in English language journals to the best of the authors' knowledge. Ga-67 citrate and Tc-99m MDP scans of the thigh mass accurately depicted the tumor's local extent, including the presence of central ischemic necrosis within the tumor, and the absence of adjacent osseous involvement and distant metastases, as correlated with computed tomography, angiography, and pathologic examinations.

  15. Arthroscopic Latarjet procedure: is optimal positioning of the bone block and screws possible? A prospective computed tomography scan analysis.

    Science.gov (United States)

    Kany, Jean; Flamand, Olivier; Grimberg, Jean; Guinand, Régis; Croutzet, Pierre; Amaravathi, Rajkumar; Sekaran, Padmanaban

    2016-01-01

    We hypothesized that the arthroscopic Latarjet procedure could be performed with accurate bone block positioning and screw fixation with a similar rate of complications to the open Latarjet procedure. In this prospective study, 105 shoulders (104 patients) underwent the arthroscopic Latarjet procedure performed by the same senior surgeon. The day after surgery, an independent surgeon examiner performed a multiplanar bidimensional computed tomography scan analysis. We also evaluated our learning curve by comparing 2 chronologic periods (30 procedures performed in each period), separated by an interval during which 45 procedures were performed. Of the 105 shoulders included in the study, 95 (90.5%) (94 patients) were evaluated. The coracoid graft was accurately positioned relative to the equator of the glenoid surface in 87 of 95 shoulders (91.5%). Accurate bone-block positioning on the axial view with "circle" evaluation was obtained for 77 of 95 shoulders (81%). This procedure was performed in a lateralized position in 7 of 95 shoulders (7.3%) and in a medialized position in 11 shoulders (11.6%). The mean screw angulation with the glenoid surface was 21°. One patient had transient axillary nerve palsy. Of the initial 104 patients, 3 (2.8%) underwent revision. The analysis of our results indicated that the screw-glenoid surface angle significantly predicted the accuracy of the bone-block positioning (P = .001). Our learning curve estimates showed that, compared with our initial period, the average surgical time decreased, and the risk of lateralization showed a statistically significant decrease during the last period (P = .006). This study showed that accurate positioning of the bone block onto the anterior aspect of the glenoid is possible, safe, and reproducible with the arthroscopic Latarjet procedure without additional complications compared with open surgery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  16. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site

    Directory of Open Access Journals (Sweden)

    M Doube

    2010-06-01

    Full Text Available Condylar fracture of the third metacarpal bone (Mc3 is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC and subchondral bone (SCB have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.

  17. Study of radionuclide bone imaging in diagnosis of skeletal metastases in patients with lung cancer%核素骨显像对肺癌骨转移特点和规律的探讨

    Institute of Scientific and Technical Information of China (English)

    周润锁; 徐海峰; 张王峰; 刘瑶娟; 穆继珍

    2001-01-01

    AIM 99Tcm-MDP bone imaging was performe d in patients with lung cancer. Characteristics and regularity of skeletal metastases was investigated. METHODS Bone metastatic sites, quantity and different pathological types were analyzed in 140 cases of skeletal metastases patients with lung cancer in recent three years. RESULTS Total skeletal metastatic rate of lung cancer was 34.1%. Thoracic bones were the most frequent metastatic sites, spinal and pelvic bone were the next. The skeletal metastaese of adenocarcinoma, squamoca rcinoma was more easily than other types of cancer. The positive rate of bone metastasis dia g-nosed by radionuclide bone imaging was rather higher than that of X -ray and X-CT. CONCLUSION Radionuclide bone imaging should be routinely perfomerd in patients with lung cancer.%目的用99Tcm-亚甲基二膦酸盐(99Tcm-MDP)对肺癌患者进行全身核素骨显像,探讨肺癌骨转移的特点和规律. 方法收集我院近三年140例肺癌骨转移病例,对骨转移的部位、数量与病理类型进行回顾性分析. 结果肺癌骨转移率为34.1%,骨转移部位以胸部骨骼为最多,其次为脊柱和骨盆. 肺腺癌、鳞癌较其它类型肺癌更易发生骨转移.全身骨显像诊断肺癌骨转移的阳性率明显高于X线摄片与X-CT.结论全身核素骨显像对骨转移的诊断最有价值,肺癌患者应常规行全身骨显像随访.

  18. Clinical value of radionuclide bone imaging in 343 primary nasopharyngeal carcinoma cases%鼻咽癌343例放射性核素骨显像的临床分析

    Institute of Scientific and Technical Information of China (English)

    邱素芳; 潘建基; 唐明灯; 林少俊; 杨凌; 林端瑜

    2008-01-01

    Objective To analyze the radionuclide bone imaging in 343 primary nasopharyngeal carcinoma cases and to know the positive ratio and its prognosis. Methods 343 cases with primary NPC were examined by radionuclide bone imaging in order to find if there was bone metastases and analyze in single and multi factors, and then to know its prognosis. Results The positive ratio of 343 NPC cases was 32.9 %, men 37.5%, women 17.7%. There was significant statistic value in sex, age and staging through Binary Logistic Regress analysis. Men, the more advanced staging, the older people, the earlier to metastases.The overall accumulate survival ratio was 1 year 92.1%, 2 year 83.9 %, 3 year 78.8 %. Conclusion Nasopharyngeal carcinoma is easy to metastases. Radionuclide bone imaging should be performed in the patients with NPC because it is important to evaluate the staging and therapy.%目的 通过分析鼻咽癌初治患者放射性核素骨显像资料,了解骨转移发生情况及其预后.方法 对343例鼻咽癌初治患者均行常规放射性核素骨显像检查,对其进行单因素及多因素分析,并在治疗后1、2、3年进行随访.结果 343例患者初诊时骨转移发生率为32.9%,其中男性37.5%,女性17.7%,多因素分析结果显示不同性别、年龄、病期间差异有统计学意义.总体累计生存率为:1年92.1%,2年83.9%,3年78.8%.结论 鼻咽癌放射性核素骨显像灵敏度较高,对鼻咽癌的诊断、分期、治疗及预后判断有重要作用,应作为鼻咽癌患者的常规检查.

  19. Predictive value of prostate-specific antigen and Gleason sum for results of radionuclide bone scintigraphy in patients with prostate cancer%前列腺特异性抗原和Gleason评分对前列腺癌患者核素骨扫描结果的预测价值

    Institute of Scientific and Technical Information of China (English)

    王天昱; 何志嵩; 周利群; 陈晓鹏; 李学松; 贾元歆; 成俊; 张建华; 蔡林; 张争; 龚侃

    2012-01-01

    该进行骨扫描检查.%Objective: To investigate the predictive value of prostate-specific antigen (PSA) and Gleason sum for results of radionuclide bone scintigraphy in prostate cancer patients, in order to determine when to perform a radionuclide bone scintigraphy in Chinese patients with newly diagnosed prostate cancer. Methods: We retrospectively reviewed the charts of 624 consecutive patients with a pathology diagnosis of prostate cancer hospitalized in Department of Urology, Peking University First Hospital between Jan. 1994 and Dec. 2005, and evaluated the relationships between results of bone scintigraphy and serum tPSA, and between bone scintigraphy and Gleason sum. The receiver operating characteristics ( ROC) curves were analyzed to determine the cut-off values of tPSA and Gleason sum for predicting positive results of bone scintigraphy. Results: In the study, 443 patients underwent both a radionuclide bone scan and a serum PSA test prior to treatment, of whom, 216 (48. 8% ) got positive results, and 338 also possessed the Gleason sum for pathological evaluation. The serum tPSA levels were significantly higher in patients with positive results of the bone scan ( median: 71.00 μg/L; range; 1.30 -2 400.00 μg/L) than those with negative results ( median; 60. 00 μg/L; range; 0. 60 - 201. 00 μg/L; rank P < 0. 001 ) , and the Gleason sums were also significantly higher in positive-bone-scan patients than in negative-bone-scan patients (7.1 ±1.5 vs. 6. 7 ± 1. 8, P <0. 001) . Linear regression analysis suggested significant positive correlation between the results of the bone scan and the two afore-mentioned parameters, respectively (lg[PSA]: r=0.933, B=0.352, P=0.001; Gleason sum; r=0.971, 5=0.096, P< 0.001 ). The incidence of a positive bone scan result was 9. 0% in patients with tPSA < 10 μg/L and 3. 8% in patients with Gleason sum <5. When the indication for bone scan was established as tPSA > 15 μg/L or Gleason sum ≥7, its sensitivity, specificity, positive predictive

  20. Scanning electron microscope analysis of gunshot defects to bone: an underutilized source of information on ballistic trauma.

    Science.gov (United States)

    Rickman, John M; Smith, Martin J

    2014-11-01

    Recent years have seen increasing involvement by forensic anthropologists in the interpretation of skeletal trauma. With regard to ballistic injuries, there is now a large literature detailing gross features of such trauma; however, less attention has been given to microscopic characteristics. This article presents analysis of experimentally induced gunshot trauma in animal bone (Bos taurus scapulae) using full metal jacket (FMJ), soft point (SP), and captive bolt projectiles. The results were examined using scanning electron microscopy (SEM). Additional analysis was conducted on a purported parietal gunshot lesion in a human cranial specimen. A range of features was observed in these samples suggesting that fibrolamellar bone response to projectile impact is analogous to that observed in synthetic composite laminates. The results indicate that direction of bullet travel can be discerned microscopically even when it is ambiguous on gross examination. It was also possible to distinguish SP from FMJ lesions. SEM analysis is therefore recommended as a previously underexploited tool in the analysis of ballistic trauma.

  1. Multiple bony lesions other than femoral heads on {sup 99m}Tc-MDP bone scan in patients with avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Chun, Hae Kyung [St. Francisco Hospital, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%); the location of 79 lesions was other than the femoral head. This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated.

  2. Focal hot spot induced by a central subclavian line on bone scan

    Directory of Open Access Journals (Sweden)

    Masood Moslehi

    2014-01-01

    Full Text Available The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration and the interpreting physicians should be aware of the impact of technical factors on image quality.

  3. Scanning Electron Microscopy Reveals Two Distinct Classes of Erythroblastic Island Isolated from Adult Mammalian Bone Marrow.

    Science.gov (United States)

    Yeo, Jia Hao; McAllan, Bronwyn M; Fraser, Stuart T

    2016-04-01

    Erythroblastic islands are multicellular clusters in which a central macrophage supports the development and maturation of red blood cell (erythroid) progenitors. These clusters play crucial roles in the pathogenesis observed in animal models of hematological disorders. The precise structure and function of erythroblastic islands is poorly understood. Here, we have combined scanning electron microscopy and immuno-gold labeling of surface proteins to develop a better understanding of the ultrastructure of these multicellular clusters. The erythroid-specific surface antigen Ter-119 and the transferrin receptor CD71 exhibited distinct patterns of protein sorting during erythroid cell maturation as detected by immuno-gold labeling. During electron microscopy analysis we observed two distinct classes of erythroblastic islands. The islands varied in size and morphology, and the number and type of erythroid cells interacting with the central macrophage. Assessment of femoral marrow isolated from a cavid rodent species (guinea pig, Cavis porcellus) and a marsupial carnivore species (fat-tailed dunnarts, Sminthopsis crassicaudata) showed that while the morphology of the central macrophage varied, two different types of erythroblastic islands were consistently identifiable. Our findings suggest that these two classes of erythroblastic islands are conserved in mammalian evolution and may play distinct roles in red blood cell production.

  4. Bone

    Science.gov (United States)

    Helmberger, Thomas K.; Hoffmann, Ralf-Thorsten

    The typical clinical signs in bone tumours are pain, destruction and destabilization, immobilization, neurologic deficits, and finally functional impairment. Primary malignant bone tumours are a rare entity, accounting for about 0.2% of all malignancies. Also benign primary bone tumours are in total rare and mostly asymptomatic. The most common symptomatic benign bone tumour is osteoid osteoma with an incidence of 1:2000.

  5. Automated Bone Scan Index as a quantitative imaging biomarker in metastatic castration-resistant prostate cancer patients being treated with enzalutamide

    DEFF Research Database (Denmark)

    Anand, Aseem; Morris, Michael J.; Larson, Steven M

    2016-01-01

    Background: Having performed analytical validation studies, we are now assessing the clinical utility of the upgraded automated Bone Scan Index (BSI) in metastatic castration-resistant prostate cancer (mCRPC). In the present study, we retrospectively evaluated the discriminatory strength of the a...

  6. The Placorhen study : A double-blind, placebo-controlled, randomized radionuclide study with Re-186-etidronate in hormone-resistant prostate cancer patients with painful bone metastases

    NARCIS (Netherlands)

    Han, SH; de Klerk, JMH; Tan, S; van het Schip, AD; Derksen, BH; van Dijk, A; Kruitwagen, CLJJ; Blijham, GH; van Rijk, PP; Zonnenberg, BA

    2002-01-01

    Re-186-1,1-hydroxyethylidene diphosphonate (etidronate) can be used for the palliative treatment of metastatic bone pain. A randomized, placebo-controlled study using Re-186-etidronate was conducted on end-stage prostate cancer patients with metastatic bone pain. Methods: Pain relief was assessed us

  7. Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

    Science.gov (United States)

    Mangano, Carlo; Piattelli, Adriano; Raspanti, Mario; Mangano, Francesco; Cassoni, Alessandra; Iezzi, Giovanna; Shibli, Jamil Awad

    2011-01-01

    Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.

  8. Comparison of 99mTc-3PRGD2 integrin receptor imaging with 99mTc-MDP bone scan in diagnosis of bone metastasis in patients with lung cancer: a multicenter study.

    Directory of Open Access Journals (Sweden)

    Weibing Miao

    Full Text Available 99mTc-3PRGD2, a promising tracer targeting integrin receptor, may serve as a novel tumor-specific agent for single photon emission computed tomography (SPECT. A multi-center study was prospectively designed to evaluate the diagnostic accuracy of 99mTc-3PRGD2 imaging for bone metastasis in patients with lung cancer in comparison with the conventional 99mTc-MDP bone scan.The patients underwent whole-body scan and chest tomography successively at both 1 h and 4 h after intravenous injection of 11.1 MBq/Kg 99mTc-3PRGD2. 99mTc-MDP whole-body bone scan was routinely performed within 1 week for comparison. Three experienced nuclear medicine physicians blindly read the 99mTc-3PRGD2 and 99mTc-MDP images. The final diagnosis was established based on the comprehensive assessment of all available data.A total of 44 patients (29 male, 59±10 years old with suspected lung cancer were recruited from 4 centers. Eighty-nine bone lesions in 18 patients were diagnosed as metastases and 23 bone lesions in 9 patients were benign. In a lesion-based analysis, 99mTc-3PRGD2 imaging demonstrated a sensitivity, specificity, and accuracy of 92.1%, 91.3%, and 92.0%, respectively. The corresponding diagnostic values for 99mTc-MDP bone scan were 87.6%, 60.9%, and 82.1%, respectively in the same patients. 99mTc-MDP bone scan had better contrast in most lesions, whereas the 99mTc-3PRGD2 imaging seemed to be more effective to exclude pseudo-positive lesions and detect bone metastases without osteogenesis.99mTc-3PRGD2 is a novel tumor-specific agent based on SPECT technology with a promising value in diagnosis of bone metastasis in patients with lung cancer.ClinicalTrials.gov NCT01737112.

  9. Automated Bone Scan Index as a quantitative imaging biomarker in metastatic castration-resistant prostate cancer patients being treated with enzalutamide

    DEFF Research Database (Denmark)

    Anand, Aseem; Morris, Michael J; Larson, Steven M;

    2016-01-01

    BACKGROUND: Having performed analytical validation studies, we are now assessing the clinical utility of the upgraded automated Bone Scan Index (BSI) in metastatic castration-resistant prostate cancer (mCRPC). In the present study, we retrospectively evaluated the discriminatory strength of the a......BACKGROUND: Having performed analytical validation studies, we are now assessing the clinical utility of the upgraded automated Bone Scan Index (BSI) in metastatic castration-resistant prostate cancer (mCRPC). In the present study, we retrospectively evaluated the discriminatory strength......-specific antigen (PSA), hemoglobin (HgB), and alkaline phosphatase (ALP) were obtained at baseline. Change in automated BSI and PSA were obtained from patients who have had bone scan at week 12 of treatment follow-up. Automated BSI was obtained using the analytically validated EXINI Bone(BSI) version 2. Kendall...... alone (C-index 0.73), p = 0.041. CONCLUSIONS: The upgraded and analytically validated automated BSI was found to be a strong predictor of OS in mCRPC patients. Additionally, the change in automated BSI demonstrated an additive clinical value to the change in PSA in mCRPC patients being treated...

  10. Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences

    Directory of Open Access Journals (Sweden)

    Henrik Lundblad

    2015-01-01

    Full Text Available Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na18F− PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs were drawn to include broken bone, other (normal bone, and muscle. The SUVm(t (m=max, mean and a series of slopes were computed as (SUVm(ti-SUVm(tj/(ti-tj, for pairs of time values ti and tj. A Patlak-like analysis was performed for the same time values by computing ((VOIp(ti/VOIe(ti-(VOIp(tj/VOIe(tj/(ti-tj, where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUVm slopes showed good agreement by both linear regression and correlation coefficient analysis (r=84%,rs=78%-SUVmax,r=92%, and rs=91%-SUVmean, suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min−1 or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of −0.06 min−1 usually indicated poor remodeling progress in this cohort.

  11. [Frostbite of the upper and lower limbs in an expert mountain climber: the value of bone scan in the prediction of amputation level].

    Science.gov (United States)

    Banzo, J; Martínez Villén, G; Abós, M D; Morandeira, J R; Prats, E; García López, F; Razola, P; Ubieto, M A

    2002-01-01

    A 38 year old man was admitted to our hospital 10 days after suffering a frostbite injury in hands and feet while practicing mountain climbing, at 8,100 meters of altitude, while he was trying to reach the top of the K2 mountain. A 99mTc-MDP bone scan performed in aseptic conditions showed: in hands: absence of bone uptake in the 3rd phalanx and distal portion of 2nd phalanx of the 5th finger of the left hand, and multiple areas of increased uptake in the distal portion of both hands. In feet: uptake decreases in the 2nd phalanx of the first toe of the left foot, and absence of bone uptake in the 3rd phalanx of the 2nd toe of the left foot, and in 2nd phalanx of the 1st toe and 3rd phalanx of the 2nd, 3rd and 4th toes of the right foot. As in the hands, there were multiple areas of increased uptake in the distal portion of both feet. The phalanges with absence of bone uptake had to be amputated, while those that presented increased uptake recovered with conservative treatment. Bone scan is indicated in the evaluation of frostbite injuries and helps to establish the prognosis early.

  12. External accumulation of radionuclide in hepatic hydrothorax

    Energy Technology Data Exchange (ETDEWEB)

    Albin, R.J.; Johnston, G.S.

    1989-05-01

    Hepatic hydrothorax is a complication in approximately 5% of patients with cirrhosis. Ascites is almost always present and helps to suggest the correct diagnosis. However, when ascites is absent, radionuclide imaging has proven to be helpful in establishing that the pleural effusion originated from ascitic fluid. When pleural fluid is rapidly removed, such as by thoracostomy tube drainage, the radioisotope may accumulate outside the thorax and produce a negative scan of the chest. When the radionuclide scan is nondiagnostic and the pleural space is being rapidly drained, the pleural fluid collecting system should always be imaged before rejecting a diagnosis of hepatic hydrothorax.

  13. Application of Radionuclide Bone Imaging Combined with Tumor Markers in the Diagnosis of Bone Metastasis in Breast Cancer Patients%核素骨显像联合肿瘤标记物检测对乳腺癌骨转移的诊断价值

    Institute of Scientific and Technical Information of China (English)

    郭小楠; 董丽

    2016-01-01

    Objective To observe the application value of radionuclide bone imaging combined with tumor markers in the diagnosis of bone metastasis in breast cancer patients .Methods 82 breast cancer patients were divided into metastasis group with 43 cases and premetastasis group with 39 cases according to the result of radionuclide bone imaging .Then 40 healthy women were selected as the control group .The results of radionuclide bone imaging and tumor markers were observed ,and the diagnostic value were compared.Results The expression level and positive rate of serum CA 125,CA15-3 and CEA of metastasis group were obviously higher,there had statistically difference (P2,there had statistically difference (P<0.05).The serum levels of CA125,CA15-3 and CEA increased gradually as bone metastatic grading increased (P<0.05).Conclusion Radionuclide bone imaging combined with tumor markers can improve the diagnostic sensitivity ,which is an important reference in the diagnosis of bone metastasis in breast cancer patients .%目的:观察核素骨显像联合肿瘤标记物对乳腺癌骨转移的诊断价值。方法选择乳腺癌患者82例,按照核素骨显像结果分为转移组43例及未转移组39例,另选取40例健康体检女性作为对照组。观察核素骨显像以及肿瘤标记物检测结果,并对其诊断价值进行考察。结果转移组血清CA125、CA15-3及CEA表达水平及阳性率显著高于未转移组及对照组,骨转移灶数目≤2患者血清CA125、CA15-3以及CEA表达水平及阳性率均显著低于骨转移灶数目>2的患者,差异均具有统计学意义(P<0.05)。且随着骨转移分级程度的升高,患者乳腺癌相关肿瘤标记物CA125、CA15-3及CEA表达水平及阳性率均呈升高趋势,各分级间差异有统计学意义( P<0.05)。结论核素骨显像联合肿瘤标记物检测可提高诊断敏感性,对于乳腺癌骨转移的诊断具有重要的参考价值。

  14. 肺癌术前核素骨显像的临床价值%Clinical Value of Radionuclide Bone Scanning in Presurgical Lung Cancer

    Institute of Scientific and Technical Information of China (English)

    肖必文; 洪巧银

    2000-01-01

    目的:通过对154例肺癌术前核素骨显像,了解其有否骨转移,从而根据转移情况重新制定治疗方案;方法:154例肺癌术前一周左右静注99mTC-MDP 740MBq~925MBq后3h行全身骨核素显像:结果:154例肺癌中39例骨显像阳性,占25.3%,伪阳性7例,占4.5%,其中多处骨转移灶(5处病灶以上)3例,占阳性数的33.3%;结论:用核素骨显像来区分术前是否有骨转移,以便尽早采用综合治疗有一定的临床意义.

  15. Analysis of radionuclide bone scan imaging of normal mandible%正常下颌骨放射性核素骨显像特征分析

    Institute of Scientific and Technical Information of China (English)

    屈伟; 丁石梅; 李昂; 王社教; 李国辉; 王景林

    2014-01-01

    目的 探讨下颌骨不同部位的放射性核素骨显像生长发育特征.方法 测量39例正常人下颌骨不同部位的放射性计数.将39例正常人分成3个年龄组A组:年龄<18岁,11例;B组:年龄18~20岁,8例;C组:年龄>20岁,20例,比较下颌骨髁突、下颌骨升支、下颌体不同部位的99mTc-MDP吸收比值和99mTc-MDP摄入量的差异值.结果 39例正常人的下颌骨髁突、下颌骨升支、下颌体99mTc-MDP吸收比值左右两侧无统计学差异(P>0.05).下颌骨髁突、下颌骨升支、下颌体99mTc-MDP摄入量差异值均<10%.三组的下颌骨骨髁突部位99mTc-MDP吸收比值分别为(1.15±0.27)、(1.39±0.35);(0.97±0.37)、(1.16±0.27);(0.69±0.36)、(0.75±0.27).A组的下颌骨髁突部位99mTc-MDP吸收比值明显高于B组和C组的数值,差异有统计学意义(P<0.05).三组中下颌骨髁突处99mTc-MDP吸收比值最高,与下颌骨升支、下颌体99mTc-MDP吸收比值差异有统计学意义(P<0.05).结论 生长发育期下颌骨髁状突、升支、体部的生长活性随年龄的增长逐渐递减,其变化以髁状突最为显著.放射性核素骨扫描能够评价下颌骨的生长活性特点,对下颌骨疾病的诊断和治疗具有积极的指导意义.

  16. Skeletal Scintigraphy (Bone Scan)

    Science.gov (United States)

    ... will insert an intravenous (IV) catheter into a vein in your hand or arm. The technologist will administer the radiopharmaceutical into a vein in your hand or arm. It takes a few hours, usually ...

  17. Automated Bone Scan Index as a quantitative imaging biomarker in metastatic castration-resistant prostate cancer patients being treated with enzalutamide.

    Science.gov (United States)

    Anand, Aseem; Morris, Michael J; Larson, Steven M; Minarik, David; Josefsson, Andreas; Helgstrand, John T; Oturai, Peter S; Edenbrandt, Lars; Røder, Martin Andreas; Bjartell, Anders

    2016-12-01

    Having performed analytical validation studies, we are now assessing the clinical utility of the upgraded automated Bone Scan Index (BSI) in metastatic castration-resistant prostate cancer (mCRPC). In the present study, we retrospectively evaluated the discriminatory strength of the automated BSI in predicting overall survival (OS) in mCRPC patients being treated with enzalutamide. Retrospectively, we included patients who received enzalutamide as a clinically approved therapy for mCRPC and had undergone bone scan prior to starting therapy. Automated BSI, prostate-specific antigen (PSA), hemoglobin (HgB), and alkaline phosphatase (ALP) were obtained at baseline. Change in automated BSI and PSA were obtained from patients who have had bone scan at week 12 of treatment follow-up. Automated BSI was obtained using the analytically validated EXINI Bone(BSI) version 2. Kendall's tau (τ) was used to assess the correlation of BSI with other blood-based biomarkers. Concordance index (C-index) was used to evaluate the discriminating strength of automated BSI in predicting OS. Eighty mCRPC patients with baseline bone scans were included in the study. There was a weak correlation of automated BSI with PSA (τ = 0.30), with HgB (τ = -0.17), and with ALP (τ = 0.56). At baseline, the automated BSI was observed to be predictive of OS (C-index 0.72, standard error (SE) 0.03). Adding automated BSI to the blood-based model significantly improved the C-index from 0.67 to 0.72, p = 0.017. Treatment follow-up bone scans were available from 62 patients. Both change in BSI and percent change in PSA were predictive of OS. However, the combined predictive model of percent PSA change and change in automated BSI (C-index 0.77) was significantly higher than that of percent PSA change alone (C-index 0.73), p = 0.041. The upgraded and analytically validated automated BSI was found to be a strong predictor of OS in mCRPC patients. Additionally, the change in automated BSI

  18. Bone Scan "Hot Spot" at the Superior Lateral Orbital Margin Fronto-zygomatic Suture Uptake Characterized with Tc-99m MDP SPECT/CT.

    Science.gov (United States)

    Thang, S P; Tan, A E H; Goh, A S W

    2011-07-01

    Findings of a solitary "hot spot" at the superior lateral orbital margin on bone scan scintigraphy is not uncommonly seen, and is often dismissed as a benign lesion. However, the exact etiology is indeterminate. We present two cases in which hybrid single photon emission computed tomography/computed tomography imaging was able to characterize and localize this uptake, demonstrating correlation to the right fronto-zygomatic suture.

  19. Osteochondroma (Bone Tumor)

    Science.gov (United States)

    ... to be the most common benign bone tumor, accounting for 35% to 40% of all benign bone ... imaging scans. Doctors may also request computed tomography (CT) scans or magnetic resonance imaging (MRI) scans to ...

  20. {sup 99m}Tc-HDP Pinhole Bone Scan Features of Undetached Osteochondritis Dissecans of the Femoral Condyle: Report of a Case with Radiography, CT, and MRI Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee [Sung Ae Hospital, Seoul (Korea, Republic of); Choi, Woo Hee [Seoul St. Mary' s Hospital, Catholic University Medical School, Seoul (Korea, Republic of)

    2009-02-15

    OCD may be initiated by arrest of bone growth and subchondral osteosclerosis followed by either cartilage hypertrophy with calcification or enfolding with osteochondral bridging. Diagnosis can be made in most instances using magnetic resonance imaging (MRI) or computed tomography (CT) or invasive arthroscopy. As to usefulness of conventional radiography (CR) opinions diverge as some held it to be of limited value while others valuable. The controversy seems to be due to semantic confusion of OCD from osteonecrosis (ON) which are different entities. This report will describe a case of undetached OCD occurred in the medial femoral condyle in a middle-aged female. It was free of symptom and incidentally discovered on {sup 99m}Tc-HDP pinhole scan performed for patellar injury. Pinhole scan findings of OCD are correlated to those of CR, CT, and MRI. An electronic search of literature failed to reveal earlier publication of bone scan features of undetached OCD. Pathologically, OCD differs from ON in that the fragment in the former condition comes off from a normal vascular bony bed while that in the latter separates from an avascular bony bed. Indeed, bone fragment in ON is devascularized but that in OCD maintains vascularity until weighted images, respectively and the halo showed low signal intensity on both T1 and T2 images.

  1. Quantitative radionuclide angiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function.

  2. Bone scintigraphy in chondroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Humphry, A.; Gilday, D.L.; Brown, R.G.

    1980-11-01

    Scintigraphy in 3 patients with chondroblastoma showed that the tumors were hyperemic and avidly accumulated the radionuclide. These changes were also present in adjacent normal bone, but to a lesser degree. This suggests that radionuclide uptake in chondroblastoma is a function of the blood supply to the tumor rather than primary matrix extraction.

  3. [Radionuclide imaging in oral implantations. Personal experience in maxillary sinus elevation].

    Science.gov (United States)

    Dimonte, M; Inchingolo, F; Minonne, A; Stefanelli, M

    2000-11-01

    Presently nuclear medicine techniques are not very popular in oral implantology, but they can play an interesting role in this surgical field too. In particular bone scan with 99mTc-MDP allows to evaluate the function of oral implants and the survival of bone grafts. We report our experience with skull bone scan in maxillary sinus lifting. We performed a three-year follow-up on 13 patients treated with inlay-one stage uni- or bilateral sinus lifting with a mixture composed of 90% bovine bone powder and of 10% small bone splinters and autogenous fibrin glue. We performed imaging studies and quantitated implant MDP uptake from the mean values at the surgical site to the 5th neck vertebral ratio (M/V index). The M/V index was also statistically compared with the one measured in 13 patients with severe resorption of distal upper dental arches (bone height less than 0.5 cm) and in 63 patients with normal dental status. Scintigraphic data were interpreted in the light of clinical, radiological and histologic findings. All oral implants appeared to be fixed and radiographs showed good positioning and bone adhesion; bone height exceeded 1 cm. Peri implant biopsy material was formed by normal mature bone tissue without bovine bone granules, necrotic areas and inflammatory cells. The highest bone activity (M/V index: 1.54-2.57) was observed 1-4 months after sinus lifting. Then MDP uptake decreases and 18 months after surgery radionuclide uptake in maxillary arches is homogeneous, with M/V values of 0.81-0.88. The average M/V value in the 18 surgical sites was clearly higher than in the resorbed (1.44 vs 0.64; Kruskall-Wallis ANOVA test; Dunn's method; p < 0.05) and normal (1.44 vs 0.73; p < 0.05) maxillary arches. 99mTc-MDP can show the transformation of newformed into mature bone and then allows in vivo visualization of implant osteointegration. The importance of our work lies in the use of radionuclide imaging to assess both the function of oral implants inserted by a

  4. Radionuclide bone imaging results of renal osteopathy%肾性骨病核素骨显像结果分析

    Institute of Scientific and Technical Information of China (English)

    黄之杰; 陈建忠; 王庆旭; 孙志勇

    2012-01-01

    目的 探讨99Tcm-亚甲基二磷酸盐(99Tcm-MDP)骨显像在肾性骨病中的应用价值.方法 选择我院2008~2011年经过确认的肾性骨病36例,行核素SPECT显像,分析其影像学表现.结果 10例双侧胫腓骨摄取增加;8例双下肢骨、6例全身长骨骨摄取不均匀;5例全身关节膨大,双侧肱骨、股骨弯曲畸形;6例全身关节膨大伴周围软组织钙化;1例全身关节膨大伴全身多处软组织包块.结论 结合临床资料,99Tcm-MDP骨显像能准确判断病变性质,可为肾性骨病的诊治提供有力依据.%Objective To discuss the application value of technetium 99Tcm- methylene diphosphonate( 99Tcm- MDP )in renal osteopathy( RO ). Methods Thirty six patients diagnosed RO in our hospital from 2008 to 2011 were selected to receive the nuclide single photon emission computed tomography( SPECT )imaging. And their manifestation was analyzed. Results The uptake of bilateral tibiofibula in 10 cases increased. Uneven bone uptake occurred in bones of both lower limbs in 8 cases and long bones over the whole body in 6 cases. In 5 cases,joint intumescentia occurred over the whole body,and the bilateral humerus and femur bones were twisted and crooked. In 6 cases,joint intumescentia occurred over the whole body combined with calcification of surrounding soft tissues. In 1 case,joint intumescentia occurred over the whole body combined with several soft tissue masses. Conclusion Associated with the clinical data,99Tcm- MDP bone imaging can accurately judge the nature of pathological changes and provide effective evidence for the diagnosis and treatment of renal osteopathy.

  5. Bone natural autofluorescence and confocal laser scanning microscopy: Preliminary results of a novel useful tool to distinguish between forensic and ancient human skeletal remains.

    Science.gov (United States)

    Capasso, Luigi; D'Anastasio, Ruggero; Guarnieri, Simone; Viciano, Joan; Mariggiò, Maria

    2017-03-01

    The fast, high-throughput distinction between palaeoanthropological/archaeological remains and recent forensic/clinical bone samples is of vital importance in the field of medico-legal science. In this paper, a novel dating method was developed using the autofluorescence of human bones and the confocal laser scanning microscope as the means to distinguish between archaeological and forensic anthropological skeletal findings. Human bones exhibit fluorescence, typically induced by natural antibiotics that are absorbed by collagen, and provide secondary, exogenous fluorophores. However, primary natural fluorescence (or autofluorescence) caused by enigmatic endogenous fluorophores is also present as a micro-phenomenon, whose nature is still obscure. Here, we show that the endogenous fluorophores are mucopolysaccharides of the Rouget-Neumann sheath and, more relevant, that the intensity of the natural fluorescence in human bone decreases in a relationship to the antiquity of the samples. These results suggest that the autofluorescence of bone is a promising technique for the assessment of skeletal remains that may be potentially of medico-legal interest. A larger study is proposed to confirm these findings and to create a predictive model between the autofluorescence intensity and the time since death. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  6. Bisphosphonate-related osteonecrosis of jaws in advanced stage breast cancer was detected from bone scan: a case report

    Science.gov (United States)

    Chirappapha, Prakasit; Thongjood, Thanaporn; Aroonroch, Rangsima

    2017-01-01

    Bisphosphonates (BPs) are indicated to treat skeletal-related events (SREs) for cancer patients with bone metastasis. We report a 79-year-old woman with advanced stage breast cancer with bone metastasis who was prescribed BPs (zoledronate), then developed osteonecrosis of jaw. We provide a brief review of the pathogenesis, diagnosis and treatment of this complication. PMID:28210558

  7. Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan; Sarcome d'Ewing agressif apparaissant comme une lesion froide sur la scintigraphie osseuse

    Energy Technology Data Exchange (ETDEWEB)

    Chatti, K.; Guezguez, M.; Maha Ben Fredj, M.; Sfar, R.; Essabbah, H. [Hopital Universitaire de Sahloul, Dept. de Medecine Nucleaire, Sahloul (Tunisia); Mtaoumi, M. [Hopital Universitaire de Sahloul, Dept. d' Orthopedie, Sousse (Tunisia); Chatti, K. [Faculte de Medecine de Monastir, Lab. de Biophysique, Monastir (Tunisia)

    2009-10-15

    Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal metastasis. Conclusion Ewing's sarcoma appears usually as an intense lesion on bone scan. Nevertheless, decreased radiopharmaceutical uptake or 'cold' lesion may be seen in aggressive Ewing's sarcoma with lytic tumor, growth of which is very rapid and bony reaction is minimal. (authors)

  8. {sup 99m}Tc-MDP bone scintigraphy findings representing osteoporosis

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Dae Gun; Moon, Tae Geon; Kim, Ji Hong; Son, Seok Man; Kim, In Ju; Kim, Yong Ki [College of Medicine, Pusan National Univ., Pusan (Korea, Republic of)

    2001-06-01

    Bone scintigraphy with {sup 99m}Tc-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of {sup 99m}Tc-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia or osteoporosis.

  9. Therapeutic radionuclides: Making the right choice

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, S.C.

    1996-08-01

    Recently, there has been a resurgence of interest in nuclear medicine therapeutic procedures. Using unsealed sources for therapy is not a new concept; it has been around since the beginnings of nuclear medicine. Treatment of thyroid disorders with radioiodine is a classic example. The availability of radionuclides with suitable therapeutic properties for specific applications, as well as methods for their selective targeting to diseased tissue have, however, remained the main obstacles for therapy to assume a more widespread role in nuclear medicine. Nonetheless, a number of new techniques that have recently emerged, (e.g., tumor therapy with radiolabeled monoclonal antibodies, treatment of metastatic bone pain, etc.) appear to have provided a substantial impetus to research on production of new therapeutic radionuclides. Although there are a number of new therapeutic approaches requiring specific radionuclides, only selected broad areas will be used as examples in this article.

  10. Dissociation between back pain and bone stress reaction as measured by CT scan in young cricket fast bowlers

    National Research Council Canada - National Science Library

    Millson, H B; Gray, J; Stretch, R A; Lambert, M I

    2004-01-01

    Bone stress reaction is prevalent among cricket fast bowlers. Few studies have addressed the sensitivity and specificity of imaging for diagnosis, and follow up assessment has been poorly investigated...

  11. Bone Scan Index as an Imaging Biomarker in Metastatic Castration-resistant Prostate Cancer: A Multicentre Study Based on Patients Treated with Abiraterone Acetate (Zytiga) in Clinical Practice.

    Science.gov (United States)

    Reza, Mariana; Ohlsson, Mattias; Kaboteh, Reza; Anand, Aseem; Franck-Lissbrant, Ingela; Damber, Jan-Erik; Widmark, Anders; Thellenberg-Karlsson, Camilla; Budäus, Lars; Steuber, Thomas; Eichenauer, Till; Wollmer, Per; Edenbrandt, Lars; Trägårdh, Elin; Bjartell, Anders

    2016-12-01

    Abiraterone acetate (AA) prolongs survival in metastatic castration-resistant prostate cancer (mCRPC) patients. To measure treatment response accurately in bone, quantitative methods are needed. The Bone Scan Index (BSI), a prognostic imaging biomarker, reflects the tumour burden in bone as a percentage of the total skeletal mass calculated from bone scintigraphy. To evaluate the value of BSI as a biomarker for outcome evaluation in mCRPC patients on treatment with AA according to clinical routine. We retrospectively studied 104 mCRPC patients who received AA following disease progression after chemotherapy. All patients underwent whole-body bone scintigraphy before and during AA treatment. Baseline and follow-up BSI data were obtained using EXINI Bone(BSI) software (EXINI Diagnostics AB, Lund, Sweden). Associations between change in BSI, clinical parameters at follow-up, and overall survival (OS) were evaluated using the Cox proportional hazards regression models and Kaplan-Meier estimates. Discrimination between variables was assessed using the concordance index (C-index). Patients with an increase in BSI at follow-up of at most 0.30 (n=54) had a significantly longer median survival time than those with an increase of BSI >0.30 (n=50) (median: 16 vs 10 mo; p=0.001). BSI change was also associated with OS in a multivariate Cox analysis including commonly used clinical parameters for prognosis (C-index=0.7; hazard ratio: 1.1; p=0.03). The retrospective design was a limitation. Change in BSI was significantly associated with OS in mCRPC patients undergoing AA treatment following disease progression in a postchemotherapy setting. BSI may be a useful imaging biomarker for outcome evaluation in this group of patients, and it could be a valuable complementary tool in monitoring patients with mCRPC on second-line therapies. Bone Scan Index (BSI) change is related to survival time in metastatic castration-resistant prostate cancer (mCRPC) patients on abiraterone acetate

  12. SU-E-T-588: Optimization of Imaging Following 223Ra Administration in Targeted Alpha-Emitting Radionuclide Therapy of Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Benabdallah, N; Bernardini, M [Hopital Europeen George Pompidou, Paris, Ile de France (France); Desbree, A [Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-roses, Ile-de-France (France); Labriolle-Vaylet, C de [Hopital Trousseau, Paris, Ile de France (France); Franck, D [Institut de Radioprotection et de Suretu Nucleaire, Fontenay Aux Roses, Ile de France (France)

    2015-06-15

    Purpose: With a growing demand of alpha-emitting radiopharmaceuticals, especially Xofigo ({sup 223}RaCl{sub 2}) which is used in the treatment of metastatic bone disease, the optimization of dosimetry becomes necessary. Indeed, in Europe, as stated on the council directive 2013/59/euratom, exposures of target volumes for radiotherapeutic purposes shall be individually planned taking into account that doses to non-target volumes and tissues shall be as low as reasonably achievable. To that aim, the possibility of imaging {sup 223}Ra was first investigated. Methods: The experiments were conducted at the Hopital Europeen Georges Pompidou with an Infinia Hawkeye 4 gamma camera, equipped with a medium-energy collimator. Imaging parameters, such as sensibility, spatial resolution and energy spectrum, were determined using several physical phantoms with a source of 6 MBq of {sup 223}Ra. Bone metastases were modeled with a NEMA Body Phantom to investigate image degradation based on the concentration of {sup 223}Ra. Results: The acquired energy spectrum allowed to visualize several photon peaks: at 85, 154 and 270 keV. Camera sensitivity measured from the phantom study was 102.3 cps/MBq for the 85 keV ± 20 %, 89.9 cps/MBq for the 154 ± 20 % window and 65.4 cps/MBq for the 270 ± 10 % window. The spatial resolution (full-width at half-maximum) was respectively 1.7, 1.9 and 1.8 cm for the three energy windows. SPECT/CT images of NEMA Body Phantom without and with attenuation have permitted to determine the best reconstruction parameters. Conclusion: This study has demonstrated that it is possible to obtain clinically relevant information from images of {sup 223}Ra. All these results will be valuable to analyze biodistribution imaging of the radiopharmaceutical in the patient body and go further in the reconstruction of patient images in order to personalize the dosimetry.

  13. Combined bilateral idiopathic necrosis of the humerus and femur heads: Bone scan, X-ray, CT, and MRI findings. Kombinierte beidseitige idiopathische Nekrose der Humerus- und Femurkoepfe: Skelettszintigraphie, Roentgen-, CT- und MRT-Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Piepenburg, R.; Hahn, K. (Mainz Univ. (Germany). Klinik fuer Nuklearmedizin); Doll, G. (Mainz Univ. (Germany). Klinik fuer Roentgendiagnostik); Grimm, J. (Mainz Univ. (Germany). Orthopaedische Klinik)

    1992-12-01

    Untreated aseptic bone necroses close to a joint commonly leads to severe secondary arthrosis and destruction of the joint within a short time. Therefore, only a diagnosis in an early stage of the disease offers the chance of a successful joint- preserving therapy. In cases of clinically suspected aseptic bone necrosis but still negative or doubtful X-ray findings, bone scans or MRI are reliable methods of verifying the diagnosis. (orig./MG).

  14. Hypothyroidism in McCune–Albright Syndrome and Role of Bone Scan in Management of Fibrous Dysplasia: An Unusual Case Scenario with Review of Literature

    Science.gov (United States)

    Kumar, Narvesh; Kheruka, Subhash Chand; Singh, Rani Kunti R.; Ravina, Mudalsha; Dutta, Deepanksha; Gambhir, Sanjay

    2017-01-01

    The McCune–Albright syndrome (MAS) is a triad of café-au-lait skin pigmentation, precocious puberty (PP), and polyostotic fibrous dysplasia of bone (FD). In general, FD seems to be the most common component of MAS but very rarely precocious puberty can be found in association with café-au-lait skin pigmentation in the absence of FD (about 1% of the cases). Therefore, a more clinically relevant definition of MAS is fibrous dysplasia of bone (FD) and at least one of the typical hyperfunctioning endocrinopathy and/or café-au-lait spots, with almost any combination possible. Bone scan can be the modality of choice to look for bone disease burden of fibrous dysplasia in most patients of MAS and may change the management accordingly. Most of the cases of MAS reported worldwide are associated with hyperthyroidism, up to best of our knowledge on the basis of literature search in pubmed and Google; no case was reported with hypothyroidism. Herein, we report a 12-year-old girl diagnosed with MAS and associated hypothyroidism. We have also reviewed the MAS related literature. PMID:28242980

  15. Hypothyroidism in McCune-Albright Syndrome and Role of Bone Scan in Management of Fibrous Dysplasia: An Unusual Case Scenario with Review of Literature.

    Science.gov (United States)

    Kumar, Narvesh; Kheruka, Subhash Chand; Singh, Rani Kunti R; Ravina, Mudalsha; Dutta, Deepanksha; Gambhir, Sanjay

    2017-01-01

    The McCune-Albright syndrome (MAS) is a triad of café-au-lait skin pigmentation, precocious puberty (PP), and polyostotic fibrous dysplasia of bone (FD). In general, FD seems to be the most common component of MAS but very rarely precocious puberty can be found in association with café-au-lait skin pigmentation in the absence of FD (about 1% of the cases). Therefore, a more clinically relevant definition of MAS is fibrous dysplasia of bone (FD) and at least one of the typical hyperfunctioning endocrinopathy and/or café-au-lait spots, with almost any combination possible. Bone scan can be the modality of choice to look for bone disease burden of fibrous dysplasia in most patients of MAS and may change the management accordingly. Most of the cases of MAS reported worldwide are associated with hyperthyroidism, up to best of our knowledge on the basis of literature search in pubmed and Google; no case was reported with hypothyroidism. Herein, we report a 12-year-old girl diagnosed with MAS and associated hypothyroidism. We have also reviewed the MAS related literature.

  16. Radionuclide Diagnosis of Pulmonary Embolism.

    Science.gov (United States)

    Hess, Søren; Madsen, Poul Henning

    2017-01-01

    Diagnostic imaging plays an integral role in the diagnostic workup of suspected pulmonary embolism, and several modalities have been employed over the years. In recent years, the choice has been narrowed to either computer tomographic or radionuclide based methods, i.e. computer tomographic angiography (CTA) and ventilation-perfusion scintigraphy (V/Q-scan). Both methods display advantages and shortcomings, and while we provide some insights into CTA and alternative methods, the paper's main focus is a review of the V/Q-scan. We discuss basic considerations, interpretation criteria, clinical value, and controversies of conventional planar lung scintigraphy as well as the more contemporary 3-dimensional imaging technique of single photon emission tomography (SPECT) with or without CT.

  17. Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs.

    Science.gov (United States)

    Brzobohatá, Hana; Prokop, Josef; Horák, Martin; Jancárek, Alexandr; Velemínská, Jana

    2012-09-01

    The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.

  18. EFFECTS OF CHEMICAL PROCESSING AND OXIDE ETHYLENE STERILIZATION ON CORTICAL AND CANCELLOUS RAT BONE: A LIGHT AND ELECTRON SCANNING MICROSCOPY STUDY.

    Science.gov (United States)

    Castiglia, Marcello Teixeira; da Silva, Juliano Voltarelli F; Frezarim Thomazini, José Armendir; Volpon, José Batista

    2009-01-01

    To evaluate, under microscopic examination, the structural changes displayed by the trabecular and cortical bones after being processed chemically and sterilized by ethylene oxide. Samples of cancellous and cortical bones obtained from young female albinus rats (Wistar) were assigned to four groups according to the type of treatment: Group I- drying; Group II- drying and ethylene oxide sterilization; III- chemical treatment; IV- chemical treatment and ethylene oxide sterilization. Half of this material was analyzed under ordinary light microscope and the other half using scanning electron microscopy. In all the samples, regardless the group, there was good preservation of the general morphology. For samples submitted to the chemical processing there was better preservation of the cellular content, whereas there was amalgamation of the fibres when ethylene oxide was used. Treatment with ethylene oxide caused amalgamation of the fibers, possibly because of heating and the chemical treatment contributed to a better cellular preservation of the osseous structure.

  19. Applica tion of Isotope bone scan imaging in Orthopaedics%同位素骨扫描成像在临床骨科的应用

    Institute of Scientific and Technical Information of China (English)

    赵统海; 焦殿雷

    2013-01-01

    目的:同位素骨扫描成像广泛应用于骨骼系统的诊断和治疗,对转移性骨肿瘤、骨髓炎及股骨头无菌性坏死具有早期诊断价值,能够早期判断移植骨是否成活,同时对原发性骨肿瘤和转移性骨肿瘤引起的骨痛具有较好的镇痛效果。%Isotope bone scan imaging w as widely used in the diagnosis and treatment of skeletal diseases. It is of early diagnostic value in metastaticosteo sarcoma, osteomyelit is and Paget,s disease,and early affirm active value in vitality of t ran splanted bone. It also demonstrates a signif- icant analgesic effect on theosteosarcom a and metastaticosteo sarcoma.

  20. A Multicenter Evaluation of Utility of Chest Computed Tomography and Bone Scans in Liver Transplant Candidates With Stages I and II Hepatoma

    Science.gov (United States)

    Koneru, Baburao; Teperman, Lewis W.; Manzarbeitia, Cosme; Facciuto, Marcelo; Cho, Kyunghee; Reich, David; Sheiner, Patricia; Fisher, Adrian; Noto, Khristian; Goldenberg, Alec; Korogodsky, Maria; Campbell, Donna

    2005-01-01

    Objective: To determine utility of practice of chest computed tomography (CCT) and bone scan (BS) in patients with early-stage hepatoma evaluated for transplantation (LT). Summary Background Data: Consensus-based policy mandates routine CCT and BS in LT candidates with hepatoma. No data exist either to support or refute this policy. Methods: From January 1999 to December 2002, stages I and II hepatoma patients evaluated at 4 centers were included. Scan interpretation was positive, indeterminate, or negative. Outcomes of evaluation and transplantation were compared between groups based on scans. Total charges incurred were derived from mean of charges at the centers. Results: One hundred seventeen stages I and II patients were evaluated. None had positive scans, 78 had negative, 29 had at least 1 indeterminate, and 10 did not have 1 or both scans. Twelve patients were declined listing, 6 from progression of hepatoma but none from CCT or BS findings. Two listed patients were delisted for progression of the hepatoma. Proportion of patients listed, transplanted, clinical and pathologic stage of hepatoma, and recurrence after LT were similar in groups with negative and indeterminate scans. Indeterminate scans led to 6 invasive procedures, 1 patient died of complications of a mediastinal biopsy, and none of the 6 showed metastases. Charges of $2933 were generated per patient evaluated. Conclusions: Positive yield of routine CCT and BS in patients with hepatoma is very low despite substantial charges and potential complications. CCT and BS performed only when clinically indicated will be a more cost-effective and safer approach. PMID:15798464

  1. Radionuclide imaging of spinal infections

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [Ghent Maria-Middelares, General Hospital, Division of Nuclear Medicine, Ghent (Belgium); Medical Center Leeuwarden (MCL), Division of Nuclear Medicine, Henri Dunantweg 2, Postbus 888, Leeuwarden (Netherlands); Dumarey, Nicolas [Universite Libre de Bruxelles, Hopital Erasme, Division of Nuclear Medicine, Brussels (Belgium); Palestro, Christopher J. [Long Island Jewish Medical Center, Division of Nuclear Medicine, Long Island, NY (United States)

    2006-10-15

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor {sup 99m}Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and {sup 67}Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [{sup 18}F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including

  2. 原发性肺癌患者治疗前后放射性核素骨显像的应用价值%Application value of radionuclide bone imaging in patients with primary pulmonary cancer before and after treatment

    Institute of Scientific and Technical Information of China (English)

    吴志兴; 吕宽; 李尚滨

    2010-01-01

    Objective To probe the application value of radionuclide bone imaging in pre-treatment selection of therapeutic plan and regular post-treatment follow-up of patients with primary pulmonary cancer.Methods 810 patients with primary pulmonary cancer had radionuclide bone imaging respectively before the treatment. The follow-up radionuclide bone imaging was performed in 492 cases that were treated by surgery in 2 years after the operation. For 318 cases that were treated by non-surgery way,only 142 cases that had no skeletal metastases had follow-up radionuclide bone imaging in 2 years after the treatment. Results 179 cases (22.1%) had skeletal metastases in 810 cases. Multiple skeletal lesions were found in 157 cases and single skeletal lesion found in 22 cases. The majority sites of skeletal metastases were ribs, vertebrae column and pelvis. 57 cases that were treated by surgery had new skeletal lesions in 2 years after the operation. For non-surgery patients,79 cases had new skeletal lesions in 2 years after the treatment. Conclusion Radionuclide bone imaging is useful in the selection of therapeutic plan and staging of primary pulmonary cancer before the treatment.Regular bone imaging after the operation is helpful to detect early bone metastasis and choose the therapeutic plan, and should be regarded as a foremost method to detect the skeletal lesion. Radionuclide bone imaging after the non-surgery treatment maybe help us to conclude the prognosis of the patients.%目的 探讨核素骨显像在原发性肺癌患者治疗前帮助确定治疗方案及治疗后定期随访的应用价值.方法 对810例原发性肺癌患者在治疗前进行了核素骨显像,对其中采用手术治疗的492例患者术后2年进行了核素骨显像随访,非手术治疗的318例患者中,治疗前无骨转移的142例患者治疗后进行了2年的核素骨显像随访.结果 在810例肺癌患者治疗前共检出骨转移179例,占22.1%,其中多发性骨转移157

  3. Radionuclides in US coals

    Energy Technology Data Exchange (ETDEWEB)

    Bisselle, C. A.; Brown, R. D.

    1984-03-01

    The current state of knowledge with respect to radionuclide concentrations in US coals is discussed. Emphasis is placed on the levels of uranium in coal (and lignite) which are considered to represent a concern resulting from coal combustion; areas of the US where such levels have been found; and possible origins of high radionuclide levels in coal. The report reviews relevant studies and presents new data derived from a computerized search of radionuclide content in about 4000 coal samples collected throughout the coterminous US. 103 references, 5 figures, 5 tables.

  4. Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Tselikas, Lambros, E-mail: lambros.tselikas@gmail.com; Joskin, Julien, E-mail: j.joskin@gmail.com [Gustave Roussy, Interventional Radiology Department (France); Roquet, Florian, E-mail: florianroquet@hotmail.com [Gustave Roussy, Biostatistics Department (France); Farouil, Geoffroy, E-mail: g.farouil@gmail.com [Gustave Roussy, Interventional Radiology Department (France); Dreuil, Serge, E-mail: serge.dreuil@gustaveroussy.fr [Gustave Roussy, Medical Physics Department (France); Hakimé, Antoine, E-mail: thakime@yahoo.com; Teriitehau, Christophe, E-mail: cteriitehau@me.com [Gustave Roussy, Interventional Radiology Department (France); Auperin, Anne, E-mail: anne.auperin@gustaveroussy.fr [Gustave Roussy, Biostatistics Department (France); Baere, Thierry de, E-mail: thierry.debaere@gustaveroussy.fr; Deschamps, Frederic, E-mail: frederic.deschamps@gustaveroussy.fr [Gustave Roussy, Interventional Radiology Department (France)

    2015-02-15

    PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.

  5. Primitive Sca-1 Positive Bone Marrow HSC in Mouse Model of Aplastic Anemia: A Comparative Study through Flowcytometric Analysis and Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Sumanta Chatterjee

    2010-01-01

    Full Text Available Self-renewing Hematopoietic Stem Cells (HSCs are responsible for reconstitution of all blood cell lineages. Sca-1 is the “stem cell antigen” marker used to identify the primitive murine HSC population, the expression of which decreases upon differentiation to other mature cell types. Sca-1+ HSCs maintain the bone marrow stem cell pool throughout the life. Aplastic anemia is a disease considered to involve primary stem cell deficiency and is characterized by severe pancytopenia and a decline in healthy blood cell generation system. Studies conducted in our laboratory revealed that the primitive Sca-1+ BM-HSCs (bone marrow hematopoietic stem cell are significantly affected in experimental Aplastic animals pretreated with chemotherapeutic drugs (Busulfan and Cyclophosphamide and there is increased Caspase-3 activity with consecutive high Annexin-V positivity leading to premature apoptosis in the bone marrow hematopoietic stem cell population in Aplastic condition. The Sca-1bright, that is, “more primitive” BM-HSC population was more affected than the “less primitive” BM-HSC Sca-1dim⁡ population. The decreased cell population and the receptor expression were directly associated with an empty and deranged marrow microenvironment, which is evident from scanning electron microscopy (SEM. The above experimental evidences hint toward the manipulation of receptor expression for the benefit of cytotherapy by primitive stem cell population in Aplastic anemia cases.

  6. Bone mineral density test

    Science.gov (United States)

    BMD test; Bone density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis-BMD ... need to undress. This scan is the best test to predict your risk of fractures. Peripheral DEXA ( ...

  7. Subject-specific bone attenuation correction for brain PET/MR: can ZTE-MRI substitute CT scan accurately?

    Science.gov (United States)

    Khalifé, Maya; Fernandez, Brice; Jaubert, Olivier; Soussan, Michael; Brulon, Vincent; Buvat, Irène; Comtat, Claude

    2017-10-01

    In brain PET/MR applications, accurate attenuation maps are required for accurate PET image quantification. An implemented attenuation correction (AC) method for brain imaging is the single-atlas approach that estimates an AC map from an averaged CT template. As an alternative, we propose to use a zero echo time (ZTE) pulse sequence to segment bone, air and soft tissue. A linear relationship between histogram normalized ZTE intensity and measured CT density in Hounsfield units (HU ) in bone has been established thanks to a CT-MR database of 16 patients. Continuous AC maps were computed based on the segmented ZTE by setting a fixed linear attenuation coefficient (LAC) to air and soft tissue and by using the linear relationship to generate continuous μ values for the bone. Additionally, for the purpose of comparison, four other AC maps were generated: a ZTE derived AC map with a fixed LAC for the bone, an AC map based on the single-atlas approach as provided by the PET/MR manufacturer, a soft-tissue only AC map and, finally, the CT derived attenuation map used as the gold standard (CTAC). All these AC maps were used with different levels of smoothing for PET image reconstruction with and without time-of-flight (TOF). The subject-specific AC map generated by combining ZTE-based segmentation and linear scaling of the normalized ZTE signal into HU was found to be a good substitute for the measured CTAC map in brain PET/MR when used with a Gaussian smoothing kernel of 4~mm corresponding to the PET scanner intrinsic resolution. As expected TOF reduces AC error regardless of the AC method. The continuous ZTE-AC performed better than the other alternative MR derived AC methods, reducing the quantification error between the MRAC corrected PET image and the reference CTAC corrected PET image.

  8. Surface morphology analysis of dental implants following insertion into bone using scanning electron microscopy: a pilot study.

    Science.gov (United States)

    Deppe, Herbert; Grünberg, Christina; Thomas, Mücke; Sculean, Anton; Benner, Klaus-Ulrich; Bauer, Florian J M

    2015-11-01

    Dental implants have become essential in reconstructive dentistry. Primary healing is determined by the design of their surface. The aim of this pilot study has been to investigate whether the morphology of the sandblasted and acid-etched (SLA(®) ) surface remains unaffected after the insertion process into human bone. Two edentulous-atrophied human jaw specimens were used. Six brand new Straumann Standard RN implants with an SLA(®) surface and having a diameter of 3.3 mm and a length of 12 mm were inserted. Another two implants of the same type, but not inserted into bone, served as a reference. After explantation, the four implants were cleaned in an ultrasonic bath and two were left uncleaned. All eight implants were inspected by SEM for qualitative surface changes. All four implants showed relevant changes of the topography at the apical thread flanks. The non-cleaned implants showed an almost complete coverage of the surface by a honeycomb-like structure, consistent with bone residues. The reference implants showed no changes. The results indicate that, for the osseointegration of dental implants, subtractive modifications of implant surfaces are less important than the reestablishment of the destroyed TiO2 layer. Further studies of other implant surfaces are required to verify the present results. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Scanning electron microscopy of collagen fiber orientation in the bone lamellar system in non-decalcified human samples.

    Science.gov (United States)

    Pannarale, L; Braidotti, P; d'Alba, L; Gaudio, E

    1994-01-01

    Previous studies on collagen fiber orientation have led to different interpretations and theories about the fiber arrangement in the lamellar compact bone. The purpose of this investigation was to provide new and more in-depth data on fiber arrangement in the lamellar bone system in order to explain the orientation of the fiber bundles. This was carried out by applying a simple method of preparation which permitted observation of non-decalcified samples. A previously isolated Haversian system was subjected to slow bending up to reaching the fracture point. Hence, the fracture surface was observed by SEM. The same samples were also observed by polarized light microscopy. A significant alternation of fiber orientation in the adjacent lamellae was observed. Different domains of differently oriented fibers were present within the same lamella; conjugating fibers connecting adjacent lamellae were also shown. This method avoided most of the artifacts due to chemical treatment of bone samples. The results can be easily interpreted by means of the same criteria applied in mechanics for the studying of composite materials.

  10. Evaluating the effect of a third-party implementation of resolution recovery on the quality of SPECT bone scan imaging using visual grading regression.

    Science.gov (United States)

    Hay, Peter D; Smith, Julie; O'Connor, Richard A

    2016-02-01

    The aim of this study was to evaluate the benefits to SPECT bone scan image quality when applying resolution recovery (RR) during image reconstruction using software provided by a third-party supplier. Bone SPECT data from 90 clinical studies were reconstructed retrospectively using software supplied independent of the gamma camera manufacturer. The current clinical datasets contain 120×10 s projections and are reconstructed using an iterative method with a Butterworth postfilter. Five further reconstructions were created with the following characteristics: 10 s projections with a Butterworth postfilter (to assess intraobserver variation); 10 s projections with a Gaussian postfilter with and without RR; and 5 s projections with a Gaussian postfilter with and without RR. Two expert observers were asked to rate image quality on a five-point scale relative to our current clinical reconstruction. Datasets were anonymized and presented in random order. The benefits of RR on image scores were evaluated using ordinal logistic regression (visual grading regression). The application of RR during reconstruction increased the probability of both observers of scoring image quality as better than the current clinical reconstruction even where the dataset contained half the normal counts. Type of reconstruction and observer were both statistically significant variables in the ordinal logistic regression model. Visual grading regression was found to be a useful method for validating the local introduction of technological developments in nuclear medicine imaging. RR, as implemented by the independent software supplier, improved bone SPECT image quality when applied during image reconstruction. In the majority of clinical cases, acquisition times for bone SPECT intended for the purposes of localization can safely be halved (from 10 s projections to 5 s) when RR is applied.

  11. Does low-field dedicated extremity MRI (E-MRI) reliably detect bone erosions in rheumatoid arthritis? A comparison of two different E-MRI units and conventional radiography with high-resolution CT scanning

    DEFF Research Database (Denmark)

    Duer-Jensen, A; Ejbjerg, B; Albrecht-Beste, E

    2008-01-01

    OBJECTIVES: To compare the ability of two different E-MRI units and conventional radiography (CR) to identify bone erosions in rheumatoid arthritis (RA) metacarpophalangeal (MCP) and wrist joints with CT scanning as the standard reference method. METHODS: 20 patients with RA and 5 controls...... underwent CR, CT and two E-MRI examinations (Esaote Biomedica Artoscan and MagneVu MV1000) of one hand during a 2-week period. In all modalities, each bone of the wrist and MCP joints was blindly evaluated for erosions. MagneVu images were also assessed for the proportion of each bone being visualised...... were visualised entirely and 37.9% of bones were 67-99% visualised. In MCP joints, 84.2% of bones were visualised entirely and 15.8% of bones were 67-99% visualised. CONCLUSION: With CT as the reference method for detecting erosions in RA hands, the Artoscan showed higher sensitivity than the Magne...

  12. 99Tcm-MDP核素骨扫描评估继发性肥大性骨关节病%Imaging observation of secondary hypertrophic osteoarthropathy by 99Tcm-methylene diphosphonate bone scans

    Institute of Scientific and Technical Information of China (English)

    徐海峰; 张王峰; 周润锁; 穆继珍

    2001-01-01

    AIM To evaluate the characteristic findings of the secondary hypertrophic osteoarthropathy (or called hypertrophic pulmonary osteoarthropathy, HPO) and differentiate the bone metastases or some osteoarthropathy diseases from HPO. METHODS Fifty-five tumor cases were confirmed on HPO with 99Tcm-MDP the whole body bone scintigraphy combined X-ray imaging and clinical manifestation. It was observed to grading scale and distribution of radionuclide in extremities, scapulae, clavicles, skull, ribs, pelvis, patella and joints referring to Ali's method. At the same time, 11 cases with HPO were followed after operation, radio-therapy and/or chemical therapy. RESULTS Double stripe sign mainly in long bones was found in all 55 cases. Involvement of the extremities was invariably present, 44 cases (87%) almost always appeared more active in the lower than in the upper extremities. There was a symmetrical , regular increase of activity along cortical margins in 46 cases (84%) and uniformity involvement in 49 cases (89%). There was also an abnormally increased activity in and around the joints in 31 cases. Whereas the observation of curative effects on HPO, there were some changes of clinical symptoms, signs and bone scan within 6~24 mo after appropriate therapy of the associated disease process, such as a complete remission or subsided in 6 cases, a fluctuating intensity of uptake in 2 cases, no improved in 1 case and aggravating in 2 cases. CONCLUSION Double stripe sign is a main characteristic findings for HPO. The distribution of the activity between bone metastases and HPO is entirely different. The follow up for HPO by bone scan will make for observation and evaluation of curative effect.%目的评价继发性肥大性骨关节病(HOA)放射性核素显像的特点与鉴别. 方法放射性核素99Tcm-MDP全身骨显像结合临床表现,对继发性HOA的肿瘤患者55例进行了核素闪烁显像分析. 参照Ali分级方法,观察了四肢骨

  13. Radionucleotide scanning in osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, W.; Kanat, I.O.

    1986-07-01

    Radionucleotide bone scanning can be an excellent adjunct to the standard radiograph and clinical findings in the diagnosis of osteomyelitis. Bone scans have the ability to detect osteomyelitis far in advance of the standard radiograph. The sequential use of technetium and gallium has been useful in differentiating cellulitis and osteomyelitis. Serial scanning with technetium and gallium may be used to monitor the response of osteomyelitis to antibiotic therapy.

  14. Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Zionts, L.E.; Harcke, H.T.; Brooks, K.M.; MacEwen, G.D.

    1987-07-01

    Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

  15. Radionuclide therapy revisited

    Energy Technology Data Exchange (ETDEWEB)

    Hoefnagel, C.A. (Nederlands Kanker Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine)

    1991-06-01

    Apart from its use in endocrinology and rheumatology, therapeutic nuclear medicine is developing rapidly as an additional treatment modality in oncology. Many different specific tumour-seeking radiopharmaceuticals are being applied both for diagnostic scintigraphy and treatment, using multiple routes and mechanisms to target radionuclides at tumours. After a brief introduction of some basic principles of radionuclide targeting, the therapeutic radiopharmaceuticals available are reviewed according to the accumulation site in relation to the cell nucleus; the results of their current clinical use for therapy are also reviewed. The response observed to a number of these applications, the non-invasiveness of the procedure and the relative lack of toxicity and late effects in comparison with chemotherapy and external beam radiotherapy make radionuclide therapy an attractive and realistic alternative in the management of malignant disease, as well as in the treatment of a few benign disorders. (orig.).

  16. Radionuclides in house dust

    CERN Document Server

    Fry, F A; Green, N; Hammond, D J

    1985-01-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, alt...

  17. Clinical value of SPECT radionuclide bone imaging in efficacy evaluation of radiotherapy and chemotherapy in bone metastases%SPECT放射性核素骨显像在转移性骨肿瘤放化疗疗效评价中的临床价值

    Institute of Scientific and Technical Information of China (English)

    杨宁; 左书耀; 王怀全; 刘冬

    2011-01-01

    目的:探讨SPECT放射性核素骨显像在转移性骨肿瘤放化疗疗效评价中的应用价值.方法:60例转移性骨肿瘤患者分为:A组,放疗联合化疗;B组,单纯放疗.在治疗后第1、3、6个月分别行骨显像检查,观察疗效差异.结果:①A组治疗后第1、3、6个月的疗效分别为63.9%、72.7%、54.3%;B组分别为52.0%、61.9%、42.2%.2组均为第3个月疗效最高.②2组间治疗后3月的疗效比较,A组均比B组高,差异均有统计学意义.治疗后第3个月2组间不同部位的疗效A组均比B组高,胸部病灶疗效差异有统计学意义(P<0.01).③治疗后第3个月2组间不同类型骨转移疗效A组均比B组高,乳腺癌骨转移的疗效差异有统计学意义 (P<0.05).结论:转移性骨肿瘤患者放化疗后定期的一系列骨显像检查对于其临床治疗决策的制订和调整具有较高的临床价值.%Objective:To explore the value of SPECT radionuclide bone in aging in the efficacy evaluation of radiotherapy and chem otherapy in bone m etastasis.M ethods: Sixty patients with bone m etastases,group A accep ted radiotherapy com bined with chem otherapy,group B accep ted radio therapy alone.After treatm ent com pletion 1,3,6 threem on ths, bone in aging inspection was rechecked separately,observing the differences of the efficay.Results:①The efficacy of the group A after treatm ent completion 1,3,6 three m on ths were:63 .9%,72 .7 %and 54 .3 %;group B:52 .0%61 .9% and 42 .2%,respectively.The efficacv of the third m on thafter treatm entw as better than the other two months in both group A and B.②The efficacy after treatment 1,3,6three m on ths in the group A were better than that in the group B,the dfferences were statistically significant.The efficacy of the differen tparts of the thid month after treatm entin the group A were better than that in the group B,the dfference was statistically significant in the chest part( P< 0.01).③The efficacy of the

  18. Radionuclide imaging of musculoskeletal infection

    Directory of Open Access Journals (Sweden)

    Christopher J. Palestro

    2007-09-01

    Full Text Available Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of "complicating osteomyelitis" such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose.Estudos através de imagens com o uso de radionuclídeos são rotineiramente usadas para avaliar pacientes suspeitos de terem infecção músculo-esquelética. A imagem óssea em tridimensional é facilmente avaliável, relativamente de baixo custo, e muito precisa na localização de alterações ósseas. Imagem com leucócito marcado poderia ser usada nos casos de "osteomielite com complicações" tais como infecção prostética articular. Esse teste também é útil na não suspeita clinica de osteomielite associada ao pé diabético tanto quanto nas junções neuropáticas. É sempre necessário, por outro lado, realizar imagem complementar da medula óssea para aumentar a precisão da imagem com leucócito marcado. Em contraste com outras regiões no esqueleto, imagem com leucócito marcado não é útil para diagnosticar osteomielite da coluna vertebral. Até agora, o gálio é o radionuclídeo preferido para

  19. Evaluation of a short dynamic 18F-fluoride PET/CT scanning method to assess bone metabolic activity in spinal orthopedics.

    Science.gov (United States)

    Peters, Marloes J M; Wierts, Roel; Jutten, Elisabeth M C; Halders, Servé G E A; Willems, Paul C P H; Brans, Boudewijn

    2015-11-01

    A complication after spinal fusion surgery is pseudarthrosis, but its radiological diagnosis is of limited value. (18)F-fluoride PET with its ability to assess bone metabolism activity could be of value. The goal of this study was to assess the clinical feasibility of calculating the static standardized uptake value (SUV) from a short dynamic scan without the use of blood sampling, thereby obtaining all dynamic and static parameters in a scan of only 30 min. This approach was tested on a retrospective patient population with persisting pain after spinal fusion surgery. In 16 patients, SUVs (SUV max, SUV mean) and kinetic parameters (K 1, k 2, k 3, v b, K i,NLR, K 1/k 2, k 3/(k 2 + k 3), K i,patlak) were derived from static and dynamic PET/CT scans of operated and control regions of the spine, after intravenous administration of 156-214 MBq (18)F-fluoride. Parameter differences between control and operated regions, as well as between pseudarthrosis and fused segments were evaluated. SUVmean at 30 and 60 min was calculated from kinetic parameters obtained from the dynamic data set (SUV mean,2TCM). Agreement between measured and calculated SUVs was evaluated through Bland-Altman plots. Overall, statistically significant differences between control and operated regions were observed for SUV max, SUV mean, K i,NLR, K i,patlak, K 1/k 2 and k 3/(k 2 + k 3). Diagnostic CT showed pseudarthrosis in 6/16 patients, while in 10/16 patients, segments were fused. Of all parameters, only those regarding the incorporation of bone [K i,NLR, K i,patlak, k 3/(k 2 + k 3)] differed statistically significant in the intervertebral disc space between the pseudarthrosis and fused patients group. The mean values of the patient-specific blood clearance rate [Formula: see text] differed statistically significant between the pseudarthrosis and the fusion group, with a p value of 0.011. This may correspond with the lack of statistical significance of the SUV values between pseudarthrosis and

  20. Necessity analysis of bone scan in patients with newly diagnosed prostate cancer%初诊前列腺癌骨扫描的必要性分析

    Institute of Scientific and Technical Information of China (English)

    周家权; 朱耀; 姚旭东; 张世林; 戴波; 张海梁; 叶定伟

    2013-01-01

    Objective To construct a classification and regression tree (CART) to predict the occurrences of bone metastases in patients with newly diagnosed prostate cancer so as to reduce unnecessary bone scans.Methods CART analyses were performed in 501 subjects from 2005 to 2011 of Fudan University Shanghai Cancer Center to establish Fudan CART model and externally validate Briganti's CART model.The both models were compared with regards to the area under the curve (AUC) and their clinical values.Results The rate of bone metastasis was 27.5% (138/501).The predictive accuracy of Fudan CART model,Briganti's CART model and skeleton-related events (SRE) model was 0.813,0.691 and 0.645 respectively.There were statistically significant differences (P < 0.05).Fudan CART model had a lower missed diagnosis and an over-examination rate of bone scan within the probability threshold (Pt) range of 24.2% to 36.8%.Conclusion With a higher predictive value,Fudan CART model may be employed to reduce the unnecessary bone scans for Chinese patients with newly diagnosed prostate cancer.%目的 建立用于预测中国初诊前列腺癌骨转移风险的回归树模型,以减少不必要的骨扫描.方法 在2005至2011年复旦大学附属肿瘤医院住院的501例初诊前列腺癌中采用分类及回归树(CART)分析建立Fudan回归树模型,同时验证Briganti回归树模型,并比较两个模型在曲线下面积(AUG)及临床应用价值上的优劣性.结果 本组骨转移的发生率为27.5%(138/501).Fudan回归树模型、Briganti回归树模型及单以骨转移相关症状(SRE)为标准预测骨转移的准确度分别为0.813、0.691及0.645,三者间比较差异有统计学意义(P<0.05).当决策阈值概率取值范围为(24.2%,36.8%)时,Fudan回归树模型具有更低的漏诊率及骨扫描过度检查率.结论 Fudan回归树模型具有较高的预测价值,同时能减少中国初诊前列腺癌不必要的骨扫描.

  1. Targeted Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    David Cheng

    2011-10-01

    Full Text Available Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose.

  2. Therapeutic radionuclides in nuclear medicine: current and future prospects.

    Science.gov (United States)

    Yeong, Chai-Hong; Cheng, Mu-hua; Ng, Kwan-Hoong

    2014-10-01

    The potential use of radionuclides in therapy has been recognized for many decades. A number of radionuclides, such as iodine-131 ((131)I), phosphorous-32 ((32)P), strontium-90 ((90)Sr), and yttrium-90 ((90)Y), have been used successfully for the treatment of many benign and malignant disorders. Recently, the rapid growth of this branch of nuclear medicine has been stimulated by the introduction of a number of new radionuclides and radiopharmaceuticals for the treatment of metastatic bone pain and neuroendocrine and other malignant or non-malignant tumours. Today, the field of radionuclide therapy is enjoying an exciting phase and is poised for greater growth and development in the coming years. For example, in Asia, the high prevalence of thyroid and liver diseases has prompted many novel developments and clinical trials using targeted radionuclide therapy. This paper reviews the characteristics and clinical applications of the commonly available therapeutic radionuclides, as well as the problems and issues involved in translating novel radionuclides into clinical therapies.

  3. Photopenia of the femoral head on 3 phase bone scan using Tc-99m MDP with acute irritable hip in the preschool children: comparison with MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Young Hoon; Lee, Jong Doo; Yoon, Choon Sik; Suh, Jin Suck; Jeon, Tae Joo [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1998-07-01

    The child with acute irritable hip is always a diagnostic challenge. Photopenia of femur head is described in Legg-Calve-Perthes disease (LCP). However, it can be seen in cases of septic arthritis (SA) with interruption of vascular supply. Despites being uncommon, recognition of SA as a cause of photopenia is important and requires urgent referral to decompression and drainage. This study was to evaluate causes and scintigraphic features of photopenia of femur head in patients with acute irritable hip and to correlate them with MR findings. 15 patients with acute irritable hip showed photopenia of femur head on bone scan were included. Mean age was 5.3 yrs ( 9 months to 8 yrs). There were 9 patients with LCP and 3 with septic arthritis combined with osteomyelitis. All parents underwent 3 phase bone scan and hip MRI within 2 days interval. Patterns of photopenia of femur head was divided into partial, complete and extending to the metaphysis. All patients with LCP showed partial photopenia confined to femur epiphysis. Whereas, 1 with septic arthritis demonstrated complete photopenia of femur head and in 2 with septic arthritis and 3 with septic arthritis combined with osteomyelitis revealed complete photopenia of femur head extending to the metaphyseal area. In cases with septic arthritis, increased uptake affecting both sides of hip joint except for photopenic area is also noted. On MRI, all patients with LCP showed abnormalities confined to the epiphysis. In cases with septic arthritis, abnormalities are not confined to the epiphysis and marrow edema and joint effusion were also noted. In evaluating photopenia of the femur head, it would be helpful to distinguish between the photopenia localized to the femoral epiphysis as seen in cases of LCP and complete photopenia of femur head with extension to the metaphysis as seen in cases of septic arthritis. Recognition of complete with extension to the metaphysis help guide urgent proper management of septic arthritis.

  4. Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim® and synthetic microcrystalline hydroxyapatite bone graft (Osteogen® in the treatment of human periodontal intrabony defects: A clinical and denta scan study

    Directory of Open Access Journals (Sweden)

    Monika Kamboj

    2016-01-01

    Full Text Available Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA (Ostim® and microcrystalline HA (Osteogen® bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim® or synthetic microcrystalline HA (Osteogen® bone graft. Clinical parameters including probing depth (PD and clinical attachment level (CAL were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties.

  5. Significance of temporal bone CT scan for exposure of the facial canal and the lateral semicircular canal in cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ki Joon; Kim, Dong Jin; Kim, Myung Soon; Kim, Young Ju; Kweon, Joon [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1991-09-15

    By reviewing retrospectively the HRCT findings in 130 surgically proven cases of chronic otitis media with cholesteatoma, we estimated the sensitivity, specificity, and positive predictability of the HRCT compared to surgical findings. For exposure of the facial canal, the sensitivity, specificity, and positive predictability was 59.7%, 84.9%, and 85.2% respectively. For exposure of the lateral semicircular canal, the sensitivity was 80.6%, the specificity 99.0%, and the positive predictability 96.2%. Conclusively, the diagnostic accuracy of preoperative temporal bone CT regarding the state of the lateral semicircular canal seems to be highly reliable. Gross invasion of the facial canal can be usually detected. However, relatively low sensitivity suggests that evaluation of the ultra-thin structures of the tympanic segment is often problematic.

  6. 女性双侧乳癌SPECT全身骨扫描显像的临床意义%Clinical significance of female double breast cancer patient's bone SPECT imaging scan

    Institute of Scientific and Technical Information of China (English)

    刘康龙; 莫逸

    2009-01-01

    目的:通过对女性双侧乳腺癌病人的SPECT全身骨扫描分析,了解骨转移病灶分布特点.方法: 病人注射99mTc-MDP显像剂,2-3小时后,行全身SPECT骨扫描.结果: 女性双侧乳腺癌病人大部分发生多发性骨转移.结论: 女性双侧乳腺癌病人,易发生多发性骨转移,常规行SPECT全身骨扫描是必要的.%Objective:To study the features of double female breast cancer patient's bone SPECT scan and bone metastasis distribution. Methods: Injection of 99mTc-MDP imaging agent was given to patient,2-3 hours later the SPECT whole bone scan was performed. Results: For most double female breast cancer patients occurred bone multiple metastases frequently. Conclusion: For double female breast cancer patients occur easy bone multiple metastases frequently,the conventional SPECT whole body bone scan is necessary.

  7. The value of Weight-Bearing CT scan in the evaluation of subtalar distraction bone block arthrodesis: Case report.

    Science.gov (United States)

    Welck, M J; Myerson, M S

    2015-12-01

    Subtalar distraction arthrodesis is performed in certain situations where there is loss of subtalar height, reduced talar declination and evidence of anterior tibiotalar impingement. Standard evaluation includes the assessment of the lateral talocalcaneal angle, calcaneal pitch, talocalcaneal height and talar declination angle on a weight bearing lateral radiograph. We present a case of erosive valgus subtalar osteoarthritis with subtalar collapse managed with a subtalar distraction arthrodesis. A weight bearing CT (WB-CT) scan was used in the assessment. The value of WB-CT for this indication is discussed, along with a discussion on surgical technique, complications and future directions. Copyright © 2015 European Foot and Ankle Society. All rights reserved.

  8. 99Tcm-MDP bone scan for the diagnosis of SAPHO syndrome%99Tcm-MDP骨显像对SAPHO综合征的诊断价值

    Institute of Scientific and Technical Information of China (English)

    刘晓梅; 魏玲格; 黄建敏

    2011-01-01

    Objective To investigate the clinical value of bone scintigraphy for the diagnosis of synovitis, acne, pustulosis, hyperostosis and osteitis (SAPHO) syndrome. Methods The characteristics of SAPHO syndrome on 99Tcm-MDP imaging of 8 cases were retrospectively analyzed. Results The 99TcmMDP bone scan was positive for all patients. Seven cases were found lesions in the costoclavicular region, 3cases involved with unilateral sacroiliac joint, 2 cases involved with spine and 1 patient with extremity. Four lesions were found without relevant clinical symptoms. Conclusion Bone scintigraphy is useful for the diagnosis of SAPHO syndrome, especially for those lesions with no clinical symptoms.%目的 探讨骨显像在滑膜炎、痤疮、脓疱病、骨肥厚、骨炎(SAPHO)综合征诊断中的临床价值.方法 回顾性分析8例SAPHO综合征的临床表现及99Tcm-MDP骨显像结果.结果 8例SAPHO综合征患者骨显像均阳性,前上胸壁异常放射性浓聚灶7例,单侧骶髂关节受累3例,颈、胸、腰椎体受累2例,肱骨及手足小关节受累1例,且发现了4处无症状的病灶.结论 骨显像的部分特征性表现有助于早期诊断及发现全身没有症状的病灶.

  9. DNA ploidy and cell cycle analyses in the bone marrow cells of patients with megaloblastic anemia using laser scanning cytometry.

    Science.gov (United States)

    Tsujioka, Takayuki; Tochigi, Aki; Kishimoto, Mitsuyo; Kondo, Toshinori; Tasaka, Taizo; Wada, Hideho; Sugihara, Takashi; Yoshida, Yataro; Tohyama, Kaoru

    2008-03-01

    Megaloblastic anemias are characterized by several hematopoietic cells with dysplastic nuclear morphology. The analyses of DNA ploidy and cell cycle of these cells are important to understand the property of such diseases. As laser scanning cytometry (LSC) is a useful tool to evaluate the morphology of the cells fixed on the slide glass together with the quantitative analysis of the fluorescence information of each cell by rapid scanning of the specimens, the authors examined the DNA ploidy and cell cycle of six cases with megaloblastic anemia using LSC. Giant neutrophilic series such as giant metamyelocytes and giant band cells were found to have extraordinarily higher DNA ploidy, while hypersegmented neutrophils represented the normal diploid pattern like normal neutrophils. As to megaloblasts, cell cycle analysis showed that the proportion of the cells in S phase was increased as compared with the case of normal erythroblasts. The present study clearly demonstrates the abnormal aspects of the hematopoietic cells with megaloblastic anemia from the viewpoint of the DNA ploidy and cell cycle analyzed by the use of LSC. (c) 2007 Clinical Cytometry Society

  10. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Salamat

    2013-01-01

    Full Text Available Objective. Although several studies have investigated the association between body mass index (BMI and bone mineral density (BMD, the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft and lumbar vertebrae (L2-L4 using a Dual-Energy X-ray Absorptiometry (DXA scan and examination of body size. Participants were categorised in two BMI group: normal weight <25.0 kg/m2 and overweight and obese, BMI ≥ 25 kg/m2. Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93 and for osteoporosis was 4.4 (1.51, 12.87 for men with BMI < 25. It was noted that BMI and weight was associated with a high BMD, compatible with a diagnosis of osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  11. Is bone mineral density measurement using dual-energy X-ray absorptiometry affected by gamma rays?

    Science.gov (United States)

    Xie, Liang-Jun; Li, Jian-Fang; Zeng, Feng-Wei; Jiang, Hang; Cheng, Mu-Hua; Chen, Yi

    2013-01-01

    The objective of this study was to determine whether the gamma rays emitted from the radionuclide effect bone mineral density (BMD) measurement. Nine subjects (mean age: 56 ± 17.96 yr) scheduled for bone scanning underwent BMD measurement using dual-energy X-ray absorptiometry (DXA) (Hologic/Discovery A) before and 1, 2, and 4 h after injection of technetium-99m-methylene diphosphonate (99mTc-MDP). Ten subjects (mean age: 41 ± 15.47 yr) scheduled for therapy of differentiated thyroid carcinoma with iodine-131 underwent BMD measurement before and 2 h after therapeutic radionuclide administration. All patients were given whole body BMD measurement, including head, arm, ribs, lumbar spine, pelvis, and leg sites. Besides, patients who referred to radioiodine therapy were given total hip and femoral neck BMD measurement as well. No statistically significant changes in BMD values were detected after 99mTc-MDP and iodine-131 administration for all measurement sites (p > 0.05), and individual difference of BMD before and after radionuclide imaging or therapy was less than the least significant change in lumbar spine, total hip, and femoral neck. In conclusion, BMD measurements are not influenced by the gamma rays emitted from technetium-99m and iodine-131. DXA bone densitometry may be performed simultaneously with bone scanning and radioiodine therapy.

  12. Detection of Unknown sites of multiple enchondroma (Ollier′s Disease mimicking like metastasis using bone scintigraphy

    Directory of Open Access Journals (Sweden)

    Koramadai Karuppusamy Kamaleshwaran

    2015-01-01

    Full Text Available Ollier′s disease characterized by multiple skeletal enchondroma is a rare noninherited disease of unknown etiology. Majority of the skeletal enchondroma are present in the metaphyses and diaphysis of tubular limb bones. Ollier′s disease has a predilection for unilateral distribution. Malignant changes in Ollier′s disease may occur in adult patients. Radionuclide bone scanning is one method used to assess lesions depicted on radiographs or magnetic resonance images that are presumed to be enchondromas. Furthermore, a bone scan may give a clue to the multifocality of the disease. We report a case of right first phalangeal enchondroma in a 23-year-old male, who underwent bone scintigraphy detected multifocal asymmetric right side involvement of radius, humerus, femur, and tibia which confirm a diagnosis of Ollier′s disease.

  13. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J. Prouty

    2006-07-14

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment (TSPA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers advective transport and diffusive transport

  14. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    R. Schreiner

    2001-06-27

    The purpose of this work is to develop the Engineered Barrier System (EBS) radionuclide transport abstraction model, as directed by a written development plan (CRWMS M&O 1999a). This abstraction is the conceptual model that will be used to determine the rate of release of radionuclides from the EBS to the unsaturated zone (UZ) in the total system performance assessment-license application (TSPA-LA). In particular, this model will be used to quantify the time-dependent radionuclide releases from a failed waste package (WP) and their subsequent transport through the EBS to the emplacement drift wall/UZ interface. The development of this conceptual model will allow Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department to provide a more detailed and complete EBS flow and transport abstraction. The results from this conceptual model will allow PA0 to address portions of the key technical issues (KTIs) presented in three NRC Issue Resolution Status Reports (IRSRs): (1) the Evolution of the Near-Field Environment (ENFE), Revision 2 (NRC 1999a), (2) the Container Life and Source Term (CLST), Revision 2 (NRC 1999b), and (3) the Thermal Effects on Flow (TEF), Revision 1 (NRC 1998). The conceptual model for flow and transport in the EBS will be referred to as the ''EBS RT Abstraction'' in this analysis/modeling report (AMR). The scope of this abstraction and report is limited to flow and transport processes. More specifically, this AMR does not discuss elements of the TSPA-SR and TSPA-LA that relate to the EBS but are discussed in other AMRs. These elements include corrosion processes, radionuclide solubility limits, waste form dissolution rates and concentrations of colloidal particles that are generally represented as boundary conditions or input parameters for the EBS RT Abstraction. In effect, this AMR provides the algorithms for transporting radionuclides using the flow geometry and radionuclide concentrations

  15. Shoulder MRI scan

    Science.gov (United States)

    ... finding on an x-ray or bone scan Shoulder pain and fever Decreased motion of the shoulder joint ... of the shoulder joint Shoulder instability Shoulder weakness Shoulder pain and a history of cancer Shoulder pain that ...

  16. Cervical spine CT scan

    Science.gov (United States)

    ... defects of the cervical spine Bone problems Fracture Osteoarthritis Disc herniation Risks Risks of CT scans include: ... Ma, MD, Assistant Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  17. Use of technetium-99m methylene diphosphonate and gallium-67 citrate scans after intraarticular injection of Staphylococcus aureus into knee joints of rabbits with chronic antigen-induced arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Mahowald, M.L.; Raskind, J.R.; Peterson, L.; Gerding, D.; Raddatz, D.A.; Shafer, R.

    1986-08-01

    Numerous clinical studies have questioned the ability of radionuclide scans to differentiate septic from aseptic joint inflammation. A clinical study may not be able to document an underlying disease process or duration of infection and, thus, may make conclusions about the accuracy of scan interpretations open to debate. In this study, the Dumonde-Glynn model of antigen-induced arthritis in rabbits was used as the experimental model to study technetium and gallium scans in Staphylococcus aureus infection of arthritic and normal joints. Gallium scans were negative in normal rabbits, usually negative in antigen-induced arthritis, but positive in septic arthritis. The bone scan was usually negative in early infection but positive in late septic arthritis, a finding reflecting greater penetration of bacteria into subchondral bone because of the underlying inflammatory process.

  18. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J.D. Schreiber

    2005-08-25

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in ''Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration'' (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment for the license application (TSPA-LA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA-LA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport

  19. Radionuclides in nephrology

    Energy Technology Data Exchange (ETDEWEB)

    Lausanne, A.B.D.

    1987-01-01

    In 47 expert contributions, this volume provides a summary of the latest research on radionuclides in nephro-urology together with current and new clinical applications especially in renovascular hypertension, kidney transplantation, and metabolic and urological diseases. In addition, attention is given to aspects of basic renal physiology and function and possible applications of nuclear magnetic resonance and spectroscopy in nephro-urology. New testing procedures which promise to improve diagnosis, and new radiopharmaceuticals are described. The reports are divided into eight sections, the first of which features studies on the renin-angiotensin system, cisplatin, atrial natriuretic factor and determining plasma oxalate. Four papers describe a number of new radiopharmaceuticals which have the potential to replace hippuran. In the third section, radionuclide methods for the measurement of renal function parameters are discussed. The book then focuses on the potential role of captopril in the improved diagnosis of renovascular hypertension. Applications of nuclear magnetic resonance and spectroscopy are demonstrated in the diagnosis of acute pyelonephritis, kidney assessment after lithotripsy, kidney evaluation prior to transplantation, and in monitoring renal ischemia during hypotension.

  20. Radionuclide - Soil Organic Matter Interactions

    DEFF Research Database (Denmark)

    Carlsen, Lars

    1985-01-01

    Interactions between soil organic matter, i.e. humic and fulvic acids, and radionuclides of primary interest to shallow land burial of low activity solid waste have been reviewed and to some extent studied experimentally. The radionuclides considered in the present study comprise cesium, strontium...

  1. TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

    Energy Technology Data Exchange (ETDEWEB)

    Perk, T; Bradshaw, T; Muzahir, S; Jeraj, R [University of Wisconsin, Madison, Wisconsin (United States); Meyer, E [Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2014-06-15

    Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate

  2. [Diagnostic value of MRI versus 99Tcm-MDP bone scan in osseous metastasis of prostate cancer: a meta-analysis].

    Science.gov (United States)

    Shen, Guohua; Zhou, Luyi; Jia, Zhiyun; Zhang, Wenjie; Wang, Qiao; Deng, Houfu

    2014-08-01

    This paper is aimed to assess the diagnostic value of MRI versus 99 Tcm-methylene diphosphonate (99 Tcm- MDP) bone scan (BS) for osseous metastases in patients with prostate cancer. The computer-based retrieval was conducted on PubMed, EMBASE, EBSCO, Web of Knowledge, the Cochrane Library and Ovid data bases to search for trials about diagnosing osseous metastases of prostate cancer with MRI and 99Tc"m-MDP BS. Selected with time acceptance and time exclusion criteria, the data quality were evaluated with QUADAS quality assessment tool and collected. We used the Meta-Disc software to conduct meta-analysis, and then calculated the pooled sensitivity, specificity and diagnostic odds ratio (DOR), drew the summary receiving operating characteristic (SROC) curve, and measured the area under curve (AUC) and Q value. Then five studies were included, involving 353 patients. The pooled sensitivity of MRI and BS was 0. 95 (95% CI 0. 90~0. 98) and 0. 67 (95% CI 0. 58~0. 75), respectively. The pooled specificity was 0. 97 (95% CI 0. 94~0. 99) and 0. 88 (95% CI 0. 83~0. 91), respectively. The pooled DOR was 402.99 (95% CI 119. 05 ~1364. 15) and 23. 85 (95% CI 1. 32~431. 48), respectively. The AUC was 0. 990 1 and 0. 624 1, respectively. The Q was 0. 958 7 and 0. 593 8. It can well be concluded that MRI is more effective than 99 Tcm-MDP BS in the diagnosis of osseous metastases in patients with prostate cancer.

  3. Current status of radionuclide scrotal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Holder, L.E.; Melloul, M.; Chen, D.

    1981-10-01

    Scrotal imaging with technetium-99m sodium pertechnetate consists of a radionuclide angiogram and static scrotal scans. Utilization of this study in patients presenting with an acute scrotum can dramatically reduce the number of surgical explorations for acute epididymitis. It can also aid in other aspects of differential diagnosis in patients presenting with either an acutely enlarged and/or painful scrotum or a scrotal mass. Ambiguities in previous descriptions of perfusion through the spermatic and extraspermatic cord vessels are described and distinguished from scrotal perfusion. The clinical and scintigraphic spectrum of testicular torsion, including spontaneous detorsion, early acute testicular torsion, midphase testicular torsion, and late phase or ''missed testicular torsion,'' is discussed and illustrated. The variety of patterns seen in acute epididymitis, including lateral and medial epididymal location, and focal epididymitis are described, as is the appearance of hydrocele as both a primary and secondary entity. The relationship of scrotal imaging to the overall clinical presentation and evaluation of these patients is emphasized in testicular torsion, torsion of the testicular appendages, epididymitis, abscess, trauma, tumor, spermatocele, and varicocele. The techniques, clinical utility, and relationship to radionuclide imaging of Doppler ultrasound and gray scale ultrasound scanning are reviewed. Doppler ultrasound results in many false negative studies in testicular torsion. Gray scale ultrasound is useful in clarifying the nature of scrotal masses.

  4. Bone-seeking therapeutic radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Srivastava Suresh C.

    2002-01-01

    Full Text Available Bone-seeking therapeutic radiopharmaceuticals are utilized on the basis of the radionuclide?s particulate emissions (primarily low to intermediate beta emission. The requirements therefore are different from those of bone imaging agents that consist mainly of short-lived single photon emitters. Lately, the therapeutic bone seeking radiopharmaceuticals have attained increasing importance due to their potential role in alleviating pain from osseous metastases in cancer patients, for the treatment of joint pain resulting from inflamed synovium (radiosynoviorthesis, or radiosynovectomy, or from various other forms of arthritic disease. There is, however, a paucity of published data on the bio-pharmacokinetics of these agents when used following intravenous administration for bone pain palliation. This paper will briefly review and summarize the presently available chemical and biopharmacokinetic information on the various clinically approved as well as experimental bone-localizing therapeutic radiopharmaceuticals, and make projections on their clinical application for the treatment of primary/metastatic cancer in bone.

  5. Radiography, Bone Scan, and F-18 FDG PET/CT Imaging Findings in a Patient with Paget's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun Tae; Kim, Sung Eun [Korea University Guro Hospital, Seoul (Korea, Republic of)

    2010-04-15

    Background A 52-year-old female patient sought evaluation at our hospital for an incidental abnormal finding on an abdominal radiograph. The initial radiograph showed irregular sclerotic changes involving the right pelvic bone. At the same time, bone scintigraphy showed intense hot uptake in the right iliac and pubic bones. CT images showed characteristic thickening of the pelvic brim, suggesting the mixed phase of Paget's disease. The level of alkaline phosphatase (ALP) was 266 IU/I. {sup 18}F-FDG PET/CT images also showed diffusely increased {sup 18}F-FDG uptake in the right pelvic bone. However, the findings of {sup 18}F-FDG PET/CT were less notable than those of bone scintigraphy. We report the imaging findings of a patient with Paget's disease evaluated by radiography, bone scintigraphy, and {sup 18}F-FDG PET/CT.

  6. Radioactivity, radionuclides, radiation

    CERN Document Server

    Magill, Joseph

    2005-01-01

    RADIOACTIVITY – RADIONUCLIDES – RADIATION is suitable for a general audience interested in topical environmental and human health radiological issues such as radiation exposure in aircraft, food sterilisation, nuclear medicine, radon gas, radiation dispersion devices ("dirty bombs")… It leads the interested reader through the three Rs of nuclear science, to the forefront of research and developments in the field. The book is also suitable for students and professionals in the related disciplines of nuclear and radiochemistry, health physics, environmental sciences, nuclear and astrophysics. Recent developments in the areas of exotic decay modes (bound beta decay of ‘bare’ or fully ionized nuclei), laser transmutation, nuclear forensics, radiation hormesis and the LNT hypothesis are covered. Atomic mass data for over 3000 nuclides from the most recent (2003) evaluation are included.

  7. Bone metastases from differentiated thyroid carcinoma.

    Science.gov (United States)

    Muresan, M M; Olivier, P; Leclère, J; Sirveaux, F; Brunaud, L; Klein, M; Zarnegar, R; Weryha, G

    2008-03-01

    The presence of distant metastases from differentiated thyroid carcinoma decreases the 10-year survival of patients by 50%. Bone metastases represent a frequent complication especially of follicular thyroid cancer and severely reduce the quality of life causing pain, fractures, and spinal cord compression. Diagnosis is established by correlating clinical suspicion with imaging. Imaging is essential to detect, localize, and assess the extension of the lesions and should be used in conjunction with clinical evidence. Bone metastases are typically associated with elevated markers of bone turnover, but these markers have not been evaluated in differentiated thyroid cancer. Skeletal and whole-body magnetic resonance imaging and fusion 2-deoxy-2-[18F]fluoro-D-glucose whole-body positron emission tomography/computed tomography (PET/CT) are the best anatomic and functional imaging techniques available in specialized centers. For well-differentiated lesions, iodine-PET scan combined (124)I-PET/CT is the newest imaging development and (131)I is the first line of treatment. Bisphosphonates reduce the complications rate and pain, alone or in combination with radioiodine, radionuclides, or external beam radiotherapy and should be employed. Surgery and novel minimally invasive consolidation techniques demand an appropriate patient selection for best results on a multimodal approach. Basic research on interactions between tumor cells and bone microenvironment are identifying potential novel targets for future more effective therapeutic interventions for less differentiated tumors.

  8. Growth Arrest Line Mimicking Lymphoma Involvement: The Findings of (99m)Tc-MDP Bone SPECT/CT and Serial Bone Scan in a Child with Non-Hodgkin's Lymphoma.

    Science.gov (United States)

    Kim, Chanwoo; Kim, Ji Young; Choi, Yun Young; Lee, Seunghun; Lee, Young-Ho

    2016-06-01

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on (99m)Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth.

  9. Growth arrest line mimicking lymphoma involvement: The findings of {sup 99m}Tc-MDP bone SPECT/CT and serial bone scan in a child with non-Hodgkin's lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Woo; Kim, Ji Young; Choi, Yun Young; Lee, Seung Hun; Lee, Young Ho [Hanyang University Medical Center, Seoul (Korea, Republic of)

    2016-06-15

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on {sup 99m}Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth.

  10. Extraosseous radiotracer uptake on bone scan in beta-thalassemia: report of one case; Fixation extraosseuse du radiotraceur lors de la realisation d'une scintigraphie du squelette chez un patient atteint de beta-thalassemie: a propos d'un cas

    Energy Technology Data Exchange (ETDEWEB)

    Guezguez, M.; Nouira, M.; Sfar, R.; Chatti, K.; Ben Fradj, M.; Ben Ali, K.; Ajmi, S.; Essabbah, H. [CHU Sahloul, Service de Medecine Nucleaire, Sousse (Tunisia); Zrour, S. [EPS F. Bourguiba, Service de Rhumatologie, Monastir (Tunisia)

    2009-10-15

    Red blood cell transfusion, main therapeutic modality of beta-thalassemia, leads to iron overload which may perturb several metabolic ways. The aim of this paper is to illustrate the uptake abnormalities observed on bone scan of thalassaemic patients and to discuss mechanisms of extraosseous accumulation of the radiopharmaceutical in this pathology. We report a 16-year-old child suffering from beta-thalassemia major undergoing transfusion therapy. A bone scan was indicated to look for osseous infection. This study revealed a little skeletal uptake and abnormal liver, splenic and renal accumulation. A repeat bone scan, performed three weeks later showed a better skeletal uptake which enabled the discovery of focal abnormalities and made the diagnostic easier. The effect of iron overload on radiopharmaceuticals uptake in bone scan is known since 1975. Dissociation of {sup 99m}Tc from the carrier ligand due to the presence of iron excess seems the most plausible hypothesis. Free {sup 99m}Tc can be bound to other tissular substrates which can explain extraosseous uptake. The normally available pool for bone is reduced and then the skeletal uptake decreased. This report limits considerably the sensitivity of the bone scan. A well-led iron chelation and eventually the use of diuretic drug may guarantee a better quality of bone scan images. (authors)

  11. Anthropogenic radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Weng, J; Wang, J

    2007-11-15

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview of anthropogenic radionuclide contamination in the environment, as well as the salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current development that contribute to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) commercial fuel reprocessing; (5) geological repository of high-level nuclear wastes, and (6) nuclear accidents. Then, we summarize the geochemical behavior for radionuclides {sup 99}Tc, {sup 129}I, and {sup 237}Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment. Biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  12. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  13. 肺癌骨转移99m Tc-MDP骨扫描最佳复查时间的研究%Patients with lung cancer 99mTc-MDP bone scan time of review

    Institute of Scientific and Technical Information of China (English)

    周友俊; 邓智勇; 孙华; 汪春; 谢燃

    2011-01-01

    目的 探讨肺癌患者骨扫描最佳复查时间.方法 对2009年6月至2010年6月昆明医学院第三附属医院核医学科收治的127例原发性肺癌患者骨扫描结果(共346例次)进行回顾性分析,按照首次骨扫描结果分为正常组(61例)和异常组(66例),比较两组患者不同间隔时间的骨扫描变化情况.结果 正常组在0~2个月、>2~4个月、>4~6个月、>6~12个月骨扫描变化率分别为1.61%(1/61)、3.3%(2/61)、13.1%(8/61)、27.9%(17/61);异常组在0~2个月、>2~4个月、>4~6个月、>6~12个月月骨扫描变化率分别为4.5%(3/66)、25.8%(17/66)、39.4%(26/66)、42.4%(28/66);正常组骨扫描变化率0~2个月与>2~4个月变化率差异无统计学意义(P>0.05);与>4~6个月、>6~12个月变化率差异有统计学意义(P<0.05);异常组0~2个月骨扫描变化率与>2~4个月、>4~6个月、>6~12个月变化率差异有统计学意义(P<0.05).结论 临床应根据首次骨扫描的结果选择适当的复查时间,首次骨扫描正常者可以将复查时间定在6个月后;首次骨扫描异常者,应将复查时间定在2~4个月.%Objective To analyze the best review time in patients with lung cancer of bone scan. Methods 127 patients with primary lung cancer patients, a total of 346 trips bone scan results were reviewed, according to the first bone scan were divided into normal group (61 cases)and abnormal group (66 cases), the two groups of patients at different intervals before and after the changes in bone scan compared and analyzed. Results Normal group in 0 ~2 months, >2 ~4 months, >4 ~6 months, >6 ~ 12 months the rate of change of bone scans were 1.61% (1/61 ), 3.3 % (2/61), 13. 1% (8/61 ), 27. 9% ( 17/61 ); Abrormal group in 0 ~ 2 months, > 2 ~ 4 months, >4 ~6 months, >6 ~ 12 months the rate of change of bone scan were 4. 5% (3/66) ,25. 8% ( 17/66),39. 4% (26/66) ,42.4% (28/66) ;Normal bone scan rate of

  14. Discordant Findings of Skeletal Metastasis Between Tc99m MDP Bone Scans and F18 FDG PET/CT Imaging for Advanced Breast and Lung Cancers—Two Case Reports and Literature Review

    Directory of Open Access Journals (Sweden)

    Yu-Wen Chen

    2007-12-01

    Full Text Available Traditionally, Tc99m methyl diphosphate (MDP bone scintigraphy provides high-sensitivity detection of skeletal metastasis from breast and lung cancers in regular follow-up. Fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT, based on the glucose metabolism of malignant cells, plays a role in describing rumor growth, proliferation of neoplasm and the extent of metastasis. In general, concordant findings of skeletal metastasis are seen on both types of image, especially in cases of breast and lung cancer. However, there were extremely discordant findings of skeletal metastasis between bone scans and F18 FDG PET/CT imaging in two cases among 300 consecutive F18 FDG PET/CT follow-up exams of patients with malignancies, during the past year, in our center. Both cases, one of breast cancer and one of lung cancer, had negative bone scintigraphic findings, but a diffusely high grade of F18 FDG avid marrow infiltration in the axial spine, leading to the diagnosis of stage IV disease in both cases. Owing to variant genetic aberrance of malignance, F18 FDG PET/CT reveals direct evidence of diffuse, rapid neoplasm metabolism in the bone marrow of the spine, but not of secondary osteoblastic reactions in vivo. F18 FDG PET/CT should always be employed in the follow-up of patients with malignancies.

  15. Vesicoureteric reflux: Evaluation by bladder volume graded direct radionuclide cystogram

    OpenAIRE

    Agrawal Vikesh; Rangarajan Venkatesh; Kamath Tejaswini; Borwankar S

    2009-01-01

    Aim : Evaluation of vesicoureteric reflux (VUR) in children by bladder volume graded direct radionuclide cystogram (BVG DRC). This technique allows detection of VUR at different bladder volume grades. Materials and Methods : In this prospective study, 33 patients (66 renal units) with suspected vesicoureteric reflux were subjected to a voiding cystourethrogram (VCUG) and BVG DRC. The patients were assessed further with radioisotope renal scans for renal cortical scars. Results : Twenty-two...

  16. Role of radionuclide scintigraphy in the detection of parathyroid adenoma

    Directory of Open Access Journals (Sweden)

    Singh N

    2007-01-01

    Full Text Available Background: Preoperative detection of parathyroid adenoma is a diagnostic challenge. The sonography and computerized tomography (CT scan demonstrate high sensitivity but low specificity. The advent of radionuclide scanning technique has enhanced the specificity in this context. Aim: We undertook a study to assess the role of radionuclide scanning in suspected cases of parathyroid adenomas. Materials And Methods: Totally 28 cases were incorporated in the study. The suspicion was raised either due to raised PTH levels or recurrent calcinosis. Most of these patients had estimation of calcium done as a routine or specific investigation. The parathyroid scan was performed using either of the two techniques - Dual isotope subtraction or Sestamibi washout technique. We also used the recent approach of fusion imaging (CT + tomographic nuclear images in selected cases. Results: There were 16 true positive, 10 true negative, 1 false negative and 1 equivocal scan findings. The findings were compared with sonography, CT Scan and PTH values. The true positive yield in our study was 57%, true negative 35% and the overall sensitivity and specificity was found to be 94% and 100% respectively. Conclusion: We conclude that parathyroid scintigraphy is a reliable and sensitive technique in the preoperative detection of parathyroid adenomas and should be the first choice of imaging modality in suspicion of parathyroid adenoma.

  17. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Wellman, Dawn M.; Jansik, Danielle P.; Golovich, Elizabeth C.; Cordova, Elsa A.

    2012-09-24

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. Data collected throughout the course of this work will be used to quantify the efficacy of concrete wasteforms, similar to those used in the disposal of LLW and MLLW, for the immobilization of key radionuclides (i.e., uranium, technetium, and iodine). Data collected will also be used to quantify the physical and chemical properties of the concrete affecting radionuclide retention.

  18. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  19. Characterization of hydrofracture grouts for radionuclide migration

    Energy Technology Data Exchange (ETDEWEB)

    Stinton, D.P.; McDaniel, E.W.; Weeren, H.O.

    1983-01-01

    Detailed characterization of hydrofracture grouts was performed by optical microscopy, scanning electron microscopy, x-ray diffraction, and ..beta..-..gamma.. autoradiography. Laboratory-produced samples containing simulated wastes as well as actual radioactive samples of hydrofracture grout sheets obtained by core drilling were examined in this work. X-ray diffraction results revealed that both laboratory-produced samples and a core-drilled sample consisted primarily of calcium carbonate phases. Both sample types contained very small amounts of strontium or cesium wastes, neither of which could be detected by microscopic techniques. The core-drilled sample contained radioactive /sup 90/Sr, /sup 137/Cs, and /sup 60/Co that could be detected by ..beta..-..gamma.. autoradiography. The autoradiograph revealed that these radionuclides were still present in the 20-year-old grout and that they had not migrated into the trapped shale fragments.

  20. Rib fractures in coronary bypass patients: radionuclide detection.

    Science.gov (United States)

    Greenwald, L V; Baisden, C E; Symbas, P N

    1983-08-01

    Sternal retraction can cause the first rib to be fractured posteriorly, injuring the brachial plexus. The authors conducted bone scans of 24 consecutive open-heart surgery patients and found an unexpectedly high number of rib fractures which in all but one case had not been seen on the chest radiograph. Bone scans are recommended whenever there is unexplained non-incisional pain in a patient who has undergone sternal retraction.

  1. [Ultrasound scanning of the distraction regenerate in case of multilocus elongation of the fragments in patients with defects of long bones].

    Science.gov (United States)

    Menshikova, T I; Borzunov, D Iu; Dolganova, T I

    2014-01-01

    It was done ultrasound examination of distraction regenerates in patients with defect of bone tissue. The first group included 4 patients who had the size of congenital bone tissue defect 15.8±8.1 cm; the second group (3 patients) included posttraumatic defects with defect size 11.75±3.6 cm; the third group (4 patients) included posttraumatic defects with defect size 11±5.3 cm. It was discovered the particularities of distraction regenerate structural condition in case of low level of reparative osteogenesis. In the first group "ischemic" regenerate was characterized by slow formation of bone trabecules. In the second group "ischemic" regenerate had one or two hypo-echogenic cystic-like formations in the intermediate regenerate area. All patients of the third group had organotypic remodeling of the regenerate according to terms of distraction and fixation.

  2. 100 years of radionuclide metrology.

    Science.gov (United States)

    Judge, S M; Arnold, D; Chauvenet, B; Collé, R; De Felice, P; García-Toraño, E; Wätjen, U

    2014-05-01

    The discipline of radionuclide metrology at national standards institutes started in 1913 with the certification by Curie, Rutherford and Meyer of the first primary standards of radium. In early years, radium was a valuable commodity and the aim of the standards was largely to facilitate trade. The focus later changed to providing standards for the new wide range of radionuclides, so that radioactivity could be used for healthcare and industrial applications while minimising the risk to patients, workers and the environment. National measurement institutes responded to the changing demands by developing new techniques for realising primary standards of radioactivity. Looking ahead, there are likely to be demands for standards for new radionuclides used in nuclear medicine, an expansion of the scope of the field into quantitative imaging to facilitate accurate patient dosimetry for nuclear medicine, and an increasing need for accurate standards for radioactive waste management and nuclear forensics.

  3. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  4. Scintigraphic bone scans in patients after total hip replacement; Badanie scyntygraficzne koscca w ocenie aseptycznego i septycznego obluzowania endoprotez stawu biodrowego

    Energy Technology Data Exchange (ETDEWEB)

    Bohatyrewicz, A.; Birkenfeld, B.; Mazurkiewicz, H.; Tustanowski, S. [Pomorska Akademia Medyczna, Szczecin (Poland)

    1993-12-31

    The results of clinical examination, three-phase bone scintigraphy and intraoperative findings were compared in 29 patients. Scintigraphic criteria of infection or aseptic loosening have been presented. The method proved to be highly useful with sensitivity and accuracy being 100, 73 and 90% respectively. (author). 17 refs, 2 figs, 2 tabs.

  5. Radiation exposure to personnel involved in bone scans for horses with technetium 99m-diphosphonat; Strahlenexposition des Personals bei der Skelettszintigrafie mit Technetium-99m-Diphosphonat beim Pferd

    Energy Technology Data Exchange (ETDEWEB)

    Sommerfeld, Theresa Christine

    2016-07-01

    Key objective of this study has been the evaluation of radiation exposure of veterinarian personnel wearing dosimeters which were involved in equine scintigraphy. A survey, which was developed in parallel to this study, showed that personnel in equine horse clinics have often knowledge gaps about scintigraphy and the related radiation doses. The survey showed skepticism of the involved personnel towards the methods of bone scintigraphy as the impacts of expositions are barely known in common. The scintigraphic investigations and measurements were done at the horse clinic (department of surgery) in Giessen and were part of the routinely bone scanning of horses. A total of 33 bone scans were taken, covering either full- or half-body scintigraphies. Additional 10 bone scans covered measurements with and without the protection of a 0,5 mm lead-shield. The activity of involved personnel was monitored at four different positions: MP1 was associated with the position of the person preparing the radiopharmaceutical for injection, MP2 with the position at holding the horse during the bone scan, MP3 with the position at holding the horse's legs and to make sure that the horse was standing in the right position, MP4 with the position for the camera operator. Some more dose measurements were made from the horse body (MP5 and MP6) as well as in the control area (MP7). In order to analyze the patient's constitution, additional data like weight, size, body extent and length of the torso were additionally captured. The body data were collected to investigate exposure differences of rather big and heavy or small and thin horses. These data and the dosimeter at the horse body (MP5) enabled the correlation analysis between the horse body composition and the received dose rate of the personnel (MP2). MP1 received a mean dose of 11 μSv and a dose rate of 123 μSv/h, MP2 received 31 μSv for a whole-body and 23 μSv for a half-body bone scan. The dose rate of MP2 was 22

  6. Radionuclide Sensors for Subsurface Water Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Timothy DeVol

    2006-06-30

    Contamination of the subsurface by radionuclides is a persistent and vexing problem for the Department of Energy. These radionuclides must be measured in field studies and monitoed in the long term when they cannot be removed. However, no radionuclide sensors existed for groundwater monitoring prior to this team's research under the EMSP program Detection of a and b decays from radionuclides in water is difficult due to their short ranges in condensed media.

  7. Luminescence imaging using radionuclides: a potential application in molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Chan [Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 700-422 (Korea, Republic of); Il An, Gwang [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Park, Se-Il [Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 700-422 (Korea, Republic of); Oh, Jungmin [Korea Basic Science Institute Chuncheon Center, Gangwon-do 200-701 (Korea, Republic of); Kim, Hong Joo [Department of Physics and Energy Science, Kyungpook National University, Daegu 702-710 (Korea, Republic of); Su Ha, Yeong; Wang, Eun Kyung [Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 700-422 (Korea, Republic of); Min Kim, Kyeong; Kim, Jung Young [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Lee, Jaetae [Department of Nuclear Medicine, School of Medicine, Kyungpook National University, Daegu 700-422 (Korea, Republic of); Welch, Michael J. [Department of Radiology, Washington University School of Medicine, St. Louis, MO 63110 (United States); Yoo, Jeongsoo, E-mail: yooj@knu.ac.k [Department of Molecular Medicine, School of Medicine, Kyungpook National University, Daegu 700-422 (Korea, Republic of)

    2011-04-15

    Introduction: Nuclear and optical imaging are complementary in many aspects and there would be many advantages when optical imaging probes are prepared using radionuclides rather than classic fluorophores, and when nuclear and optical dual images are obtained using single imaging probe. Methods: The luminescence intensities of various radionuclides having different decay modes have been assayed using luminescence imaging and in vitro luminometer. Radioiodinated Herceptin was injected into a tumor-bearing mouse, and luminescence and microPET images were obtained. The plant dipped in [{sup 32}P]phosphate solution was scanned in luminescence mode. Radio-TLC plate was also imaged in the same imaging mode. Results: Radionuclides emitting high energy {beta}{sup +}/{beta}{sup -} particles showed higher luminescence signals. NIH3T6.7 tumors were detected in both optical and nuclear imaging. The uptake of [{sup 32}P]phosphate in plant was easily followed by luminescence imaging. Radio-TLC plate was visualized and radiochemical purity was quantified using luminescence imaging. Conclusion: Many radionuclides with high energetic {beta}{sup +} or {beta}{sup -} particles during decay were found to be imaged in luminescence mode due mainly to Cerenkov radiation. 'Cerenkov imaging' provides a new optical imaging platform and an invaluable bridge between optical and nuclear imaging. New optical imaging probes could be easily prepared using well-established radioiodination methods. Cerenkov imaging will have more applications in the research field of plant science and autoradiography.

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses ... assess trauma patients in emergency departments. A CT scan can image complicated fractures, subtle fractures or dislocations. ...

  9. Value of bone scan semi-quantitative analysis in monitoring osteoporosis therapy efficacy%骨显像半定量分析在骨质疏松疗效监测中的应用

    Institute of Scientific and Technical Information of China (English)

    楼菁菁; 刘江; 董科

    2014-01-01

    Objective To explore application value of 99Tcm-MDP bone scanning semi-quantitative analysis in monitor-ing the osteoporosis therapy efficacy in early-stage. Methods From January 2011 to October 2013, in Central Hospital of Jinhua City of Zhejiang Province, 18 women with osteoporotic were chosen, and they were 50-72 years old. Before and 3 months after the Alendronate treatment, they were respectively checked with 99Tcm-MDP bone scanning and bone mineral density (BMD) measurement. The regions of interest (ROI) technology was used for obtaining the radioactive counts ratios (ROI ratios) of L1-L4 and femoral neck. BMD and ROI ratios of L1-L4 and femoral neck before and 3 months after the treatmnet were compared. Results The BMD of L1-L4 and femoral neck after 3-month treatment with Alendronate were higher than those before the treatment, and BMD of L3-L4 were compared with those before the treat-ment, the differences were statistically significant (P < 0.05). Bone scanning showed that ROI ratios of L1-L4 and femoral neck after the treatment were lower than those before the treatment, the differences were statistically significant (P< 0.05). Conclusion 99Tcm-MDP bone scanning semi-quantitative analysis can accurately reflect the early changes of bone metabolism after therapy, which has a potential application value in monitoring the therapy efficacy.%目的:探讨99Tcm-MDP骨显像半定量分析在骨质疏松疗效早期监测中的应用价值。方法选取2011年1月~2013年10月浙江省金华市中心医院收治的18例骨质疏松妇女,年龄50~72岁。阿仑膦酸钠治疗前及治疗后3个月分别进行99Tcm-MDP全身骨显像和骨密度值测量,利用感兴区(ROI)技术获取骨显像的L1~L4和股骨颈ROI比值并与治疗前进行对比,进行骨代谢骨质半定量分析。结果骨质疏松患者阿仑膦酸钠治疗后3个月骨密度显示,L1~L4及股骨颈骨密度值均高于治疗前,且L3和L4骨密度值与治疗前比较

  10. Modeling radionuclide migration from underground nuclear explosions

    Energy Technology Data Exchange (ETDEWEB)

    Harp, Dylan Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stauffer, Philip H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Viswanathan, Hari S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Karra, Satish [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pandey, Sachin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); O' Malley, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Anderson, Dale [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-06

    The travel time of radionuclide gases to the ground surface in fracture rock depends on many complex factors. Numerical simulators are the most complete repositories of knowledge of the complex processes governing radionuclide gas migration to the ground surface allowing us to verify conceptualizations of physical processes against observations and forecast radionuclide gas travel times to the ground surface and isotopic ratios

  11. Chemistry and analysis of radionuclides

    CERN Document Server

    Lehto, Jukka

    2010-01-01

    Written by chemists for chemists, this is a comprehensive guide to the important radionuclides as well as techniques for their separation and analysis. It introduces readers to the important laboratory techniques and methodologies in the field, providing practical instructions on how to handle nuclear waste and radioactivity in the environment.

  12. Tumor Immunotargeting Using Innovative Radionuclides

    Directory of Open Access Journals (Sweden)

    Françoise Kraeber-Bodéré

    2015-02-01

    Full Text Available This paper reviews some aspects and recent developments in the use of antibodies to target radionuclides for tumor imaging and therapy. While radiolabeled antibodies have been considered for many years in this context, only a few have reached the level of routine clinical use. However, alternative radionuclides, with more appropriate physical properties, such as lutetium-177 or copper-67, as well as alpha-emitting radionuclides, including astatine-211, bismuth-213, actinium-225, and others are currently reviving hopes in cancer treatments, both in hematological diseases and solid tumors. At the same time, PET imaging, with short-lived radionuclides, such as gallium-68, fluorine-18 or copper-64, or long half-life ones, particularly iodine-124 and zirconium-89 now offers new perspectives in immuno-specific phenotype tumor imaging. New antibody analogues and pretargeting strategies have also considerably improved the performances of tumor immunotargeting and completely renewed the interest in these approaches for imaging and therapy by providing theranostics, companion diagnostics and news tools to make personalized medicine a reality.

  13. Radionuclide Diagnosis of Pulmonary Embolism

    DEFF Research Database (Denmark)

    Hess, Søren; Madsen, Poul Henning

    2016-01-01

    Diagnostic imaging plays an integral role in the diagnostic workup of suspected pulmonary embolism, and several modalities have been employed over the years. In recent years, the choice has been narrowed to either computer tomographic or radionuclide based methods, i.e. computer tomographic angio...

  14. Sealing ability of mineral trioxide aggregate, calcium phosphate and polymethylmethacrylate bone cements on root ends prepared using an Erbium: Yttriumaluminium garnet laser and ultrasonics evaluated by confocal laser scanning microscopy.

    Science.gov (United States)

    Girish, C Sabari; Ponnappa, Kc; Girish, Tn; Ponappa, Mc

    2013-07-01

    Surgical endodontic therapy comprises of exposure of the involved root apex, resection of the apical end of the root, preparation of a class I cavity, and insertion of a root end filling material. Mineral trioxide aggregate (MTA) is now the gold standard among all root end filling materials. MTA is however difficult to handle, expensive and has a very slow setting reaction. (1) To compare the sealing ability of MTA, polymethylmethacrylate (PMMA) bone cement and CHITRA Calcium phosphate cement (CPC) when used as root end filling material using Rhodamine B dye evaluated under a confocal laser scanning microscope. (2) To compare the seal of root ends prepared using an ultrasonic retroprep tip and an Er: YAG laser using three different root end filling materials. Statistical analysis was performed using a one-way ANOVA and a two-way ANOVA, independent samples t-test and Scheffe's post hoc test using SPSS Version 16 for Windows. All the three materials, namely MTA, PMMA BONE CEMENT and CHITRA CPC, showed microleakage. Comparison of microleakage showed maximum peak value of 0.86 mm for MTA, 0.24 mm for PMMA bone cement and 1.37 mm for CHITRA CPC. The amount of dye penetration was found to be lesser in root ends prepared using Er: YAG laser when compared with ultrasonics, but the difference was found to be not statistically significant. PMMA bone cement is a better material as root end filling material to prevent apical microleakage. MTA still continues to be a gold standard root end filling material showing minimum microleakage. Er: YAG laser is a better alternative to ultrasonics for root end preparations.

  15. Conditions and processes affecting radionuclide transport

    Science.gov (United States)

    Simmons, Ardyth M.; Neymark, Leonid A.

    2012-01-01

    Characteristics of host rocks, secondary minerals, and fluids would affect the transport of radionuclides from a previously proposed repository at Yucca Mountain, Nevada. Minerals in the Yucca Mountain tuffs that are important for retarding radionuclides include clinoptilolite and mordenite (zeolites), clay minerals, and iron and manganese oxides and hydroxides. Water compositions along flow paths beneath Yucca Mountain are controlled by dissolution reactions, silica and calcite precipitation, and ion-exchange reactions. Radionuclide concentrations along flow paths from a repository could be limited by (1) low waste-form dissolution rates, (2) low radionuclide solubility, and (3) radionuclide sorption onto geological media.

  16. Bone tumor

    Science.gov (United States)

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor; Bone tumor - benign ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  17. Radionuclide imaging of non osseous infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestro, C.J. (Long Island Jewish Medical Center, New York, NY, (United States). Dept. Nuclear Medicine New York, Yeshiva Univ., NY (United States). Albert Einstein College of Medicine); Torres, M.A. (Long Island Jewish Medical Center, New York, NY, (United States). Dept. Nuclear Medicine)

    1999-03-01

    Nuclear medicine is an important tool in the diagnostic evaluation of patients with a variety of non osseous infections. In the immunocompetent population labeled leukocyte imaging is the radionuclide procedure of choice, with Gallium imaging reserved for those situations in which the leukocyte study is non diagnostic or cannot be performed. Fever of unknown origin is caused by infection in less than one-third of cases, and therefore the number of positive leukocyte studies will be relatively low. The negative leukocyte study is also useful as it has been demonstrated that a negative study excludes, with a high degree of certainty, focal infection as the cause of an FUO. In the cardiovascular system, labeled leukocyte scintigraphy is very useful for diagnosing mycotic aneurysms and infected prosthetic vascular grafts. The specificity of the study is somewhat more variable. In the central nervous system, labeled leukocyte imaging can provide important information about the etiology of contrast enhancing brain lesions identified on computed tomography. In the immunocompromised population, typified by the AIDS patient, Gallium scintigraphy is the radionuclide procedure of choice for diagnosing opportunistic diseases. In the thorax, a normal Gallium scan, in the setting of a negative chest X-ray, virtually excludes pulmonary disease. In the abdomen, Gallium is also useful for detecting nodal disease, but is not reliable for detecting large bowel disease. Labeled leukocyte imaging should be performed when colitis is a concern. Both [sup 18]FDG PET and [sup 201]T1 SPECT imaging of the brain are useful for distinguishing between central nervous system lymphoma and toxoplasmosis in the HIV (+) patient. On both studies, lymphoma manifests as a focus of increased tracer uptake, whereas toxoplasmosis shows little or no uptake of either tracer.

  18. Unusual Soft Tissue Uptake of F-18 Sodium Fluoride in Three Patients Undergoing F-18 NaF PET/CT Bone Scans for Prostate Cancer.

    Science.gov (United States)

    Hawkins, Andrew S; Howard, Brandon A

    2017-09-01

    Three males aged 71 to 80 years with known stage IV metastatic prostate cancer underwent F-18 sodium fluoride (NaF) PET/CT to assess osseous metastatic disease burden and stability. In addition to F-18 NaF avid known osseous metastases, each patient also exhibited increased F-18 NaF activity in soft tissues. The first patient exhibited multiple F-18 NaF avid enlarged retroperitoneal and pelvic lymph nodes on consecutive PET/CT scans. The second patient demonstrated an F-18 NaF avid thyroid nodule on consecutive PET/CT scans. The third patient exhibited increased F-18 NaF activity in a hepatic metastasis.

  19. Radionuclide synovectomy - essentials for rheumatologists.

    Science.gov (United States)

    Chojnowski, Marek M; Felis-Giemza, Anna; Kobylecka, Małgorzata

    2016-01-01

    Radionuclide synovectomy is a minimally invasive method of treating persistent joint inflammation. It involves intra-articular injection of radioactive colloids which induce necrosis and fibrosis of hypertrophic synovial membrane. The most common indication for radiosynovectomy is rheumatoid arthritis, although patients with seronegative spondyloarthropathies, unclassified arthritis, haemophilic arthropathy and other less common arthropathies can also benefit from this method. Radiosynovectomy is safe, well tolerated and efficacious. About 70-80% of patients respond well to the therapy. However, the therapeutic effects are considerably worse in patients with co-existent osteoarthritis and advanced joint degeneration. Despite its advantages, radionuclide synovectomy is not performed as often as it could be, so greater knowledge and understanding of this method are needed. The authors present the most important facts about radiosynovectomy that may help rheumatologists in their daily clinical practice.

  20. Radionuclide behavior at underground environment

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal.

  1. Can bone scan be spared in asymptomatic prostate cancer patients at the initial stage of diagnosis?%无骨转移症状前列腺癌患者免于骨扫描的临床研究

    Institute of Scientific and Technical Information of China (English)

    薛学义; 孙雄林; 范武林; 许宁; 陈少豪; 陈慧军; 蔡海; 李晓东; 魏勇; 郑清水

    2014-01-01

    目的:探讨前列腺特异性抗原(PSA)<20 ng/ml 和 Gleason评分<8分无骨转移症状前列腺癌患者免于骨扫描的截点是否适用于我国,并探寻适用于国人的截点。方法回顾性分析我院2003年5月至2012年12月经病理确诊并行骨扫描检查的无骨转移症状前列腺癌患者257例,对年龄、碱性磷酸酶、PSA值、Gleason评分、骨扫描结果等临床资料进行统计分析。结果骨转移阳性67例(26.1%);骨转移阳性组PSA值、Gleason评分与骨转移阴性组差异具有统计学意义(P<0.05)。PSA水平、Gleason 评分越高,骨转移发生率增高(P<0.05)。单因素及多因素Logistic回归分析示PSA、Gleason评分为骨转移的独立预测因子。PSA<10 ng/ml 和 Gleason 评分≤6分的35例中无骨转移阳性病例(阴性预测值100%),而 PSA<20 ng/ml 和 Gleason评分<8分的81例中3例骨转移阳性(阴性预测值96.3%)。结论 PSA 值、Gleason 评分是骨转移阳性的独立预测因子;PSA<20 ng/ml和 Gleason评分<8可免于骨扫描的截点并不适用于我国,而以PSA<10 ng/ml和Gleason评分≤6作为截点可能更适用于我国。%Objective To investigate if it is suitable for our country to set prostate-specific an-tigen (PSA)level<20 ng/ml and Gleason score<8 as the cut point below which a bone scan can be spared in prostate cancer patients with no symptoms of bone metastases,and the suitable cut point for us. Methods We retrospectively reviewed the charts of 257 consecutive patients with a pathol-ogy diagnosis of prostate cancer hospitalized in our department between May.2003 and Dec.2012, and evaluated age,serum tPSA,Gleason sum and bone scan. Results 67 (26.1%)patients got positive results.The serum PSA levels and Gleason score were significantly higher (P<0.05)in patients with positive results of the bone scan than those with negative results.With the increase of PSA level and Gleason score,the incidence of bone metastasis increased (P<0

  2. [Radionuclide diagnosis of kidney calculi].

    Science.gov (United States)

    Vlakhov, N; Penkova, D

    1986-09-01

    Radionuclide investigations were conducted in 322 patients with nephrolithiasis. Unilateral calculosis was established in 46.3% of the patients, bilateral calculosis in 50.6%. The nature of changes on renograms, scintigrams and in clearance values was shown to depend on the localization of concrements, their size and the presence of concomitant infection. A conclusion has been made as to the usefulness of the methods with relation to operative treatment, especially in a bilateral localization of a pathological renal process.

  3. Chernobyl radionuclide distribution and migration.

    Science.gov (United States)

    Izrael, Yury A

    2007-11-01

    The accident at Unit No. 4 of the Chernobyl Nuclear Power Plant on 26 April 1986 presented severe challenges in radiation protection. Early activity measurements defined the contaminated areas in order to determine what persons should be evacuated on the basis of the exposure limit at that time of 100 mSv (10 rem) for accidents. The immediate definition of these areas was accomplished with specially equipped aircraft capable of measuring external gamma-exposure rate and radionuclide spectra. Over time, maps of 137Cs contamination (the most important long-lived radionuclide) have become more and more sophisticated and have been used for further determinations of the control of the consequences of the accident. About 70% of the total release of 137Cs was deposited in Belarus, the Russian Federation, and Ukraine; but there was also widespread deposition throughout the countries of Western Europe. Two atlases of contamination throughout Europe were prepared, and the Russian atlas included data on other radionuclides and on external gamma-exposure rates. The radiocesiums behaved as volatile radionuclides because of the volatility of cesium. In contrast to the typical pattern after nuclear weapons tests, 90Sr behaved only as a refractory element, as its volatile precursors krypton and rubidium had already decayed within the reactor. Nearly all of the refractory elements (strontium, plutonium, etc.) released by the accident were confined to the 30-km zone around the reactor. A proposal is made to develop a more complete atlas of 137Cs deposition from the accident that would include the entire Northern Hemisphere. Water was not an important vector of exposure to human beings following the accident.

  4. Radionuclide behavior in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Tveten, U. (Institutt for Energiteknikk, Kjeller (Norway))

    1991-09-01

    The purpose of this report is to document the results of the following task: Review for quality and consistency the available data on measurements of initial ground contamination of Chernobyl radionuclides in various parts of Norway and subsequent concentrations of these radionuclides in various environmental media as functions of time. Utilize the data obtained to verify the existing models, or to improve them, for describing radionuclide behavior in the environment. Some of the processes standard were: migration into soil; weathering; resuspension; food-chain contamination; and loss or reconcentration by run-off. The task performed within this contract has been to use post-Chernobyl data from Norway to verify or find areas for possible improvement in the chronic exposure pathway models utilized in MACCS. Work has consisted mainly of collecting and evaluating post-Chernobyl information from Norway or other countries when relevant; but has also included experimental work performed specifically for the current task. In most connections the data available show the models and data in MACCS to be appropriate. A few areas where the data indicate that the MACCS approach is faulty or inadequate are, however, pointed out in the report. These should be examined carefully, and appropriate modifications should eventually be made. 14 refs., 12 figs., 22 tabs.

  5. Point-of-Care Phalangeal Bone Mineral Density Measurement Can Reduce the Need of Dual-Energy X-Ray Absorptiometry Scanning in Danish Women at Risk of Fracture

    DEFF Research Database (Denmark)

    Holmberg, Teresa; Bech, Mickael; Gram, Jeppe;

    2016-01-01

    Identifying persons with a high risk of osteoporotic fractures remains a challenge. DXA uptake in women with elevated risk of osteoporosis seems to be depending on distance to scanning facilities. This study aimed to investigate the ability of a small portable scanner in identifying women...... with reduced bone mineral density (BMD), and to define triage thresholds for pre-selection. Total hip and lumbar spine BMD was measured by dual-energy X-ray absorptiometry and phalangeal BMD by radiographic absorptiometry in 121 Danish women with intermediate or high 10-year fracture probability (aged 61......-81 years). Correlation between the two methods was estimated using correlation coefficient (r) and Bland-Altman plots. A moderate correlation between phalangeal BMD versus total hip (r = 0.47) and lumbar spine (r = 0.51), and an AUC on 0.80 was found. The mean difference between phalangeal T score...

  6. Early postoperative bone scintigraphy in the evaluation of microvascular bone grafts in head and neck reconstruction

    Directory of Open Access Journals (Sweden)

    Poissonnet Gilles

    2007-04-01

    Full Text Available Abstract Background Bone scintigraphy was performed to monitor anastomotic patency and bone viability. Methods In this retrospective study, bone scans were carried out during the first three postoperative days in a series of 60 patients who underwent microvascular bone grafting for reconstruction of the mandible or maxilla. Results In our series, early bone scans detected a compromised vascular supply to the bone with high accuracy (p Conclusion When performing bone scintigraphy during the first three postoperative days, it not only helps to detect complications with high accuracy, as described in earlier studies, but it is also an additional reliable monitoring tool to decide whether or not microvascular revision surgery should be performed. Bone scans were especially useful in buried free flaps where early postoperative monitoring depended exclusively on scans. According to our experience, we recommend bone scans as soon as possible after surgery and immediately in cases suspicious of vascularized bone graft failure.

  7. 99mTc-MDP bone scan combined with CT in the clinical value of breast cancer%99mTc-MDP骨显像联合CT在乳腺癌术后的临床价值

    Institute of Scientific and Technical Information of China (English)

    黄晓红; 智生芳; 蒋宁一

    2010-01-01

    Objective To evaluate the value of clinical application of the combination of CT and 99mTc-MDP bone scan in the follow-up monitoring of cancer recurrences of the breast cancer patients previously treated with both mastecomy and chemotherapy Methods 253 female breast cancer patients treated with mastectomy and chemotherapy within the past one year were enrolled in this study. All of them underwent CT,99mTc-MDP bone scan. calculation of the sensitivity, specialty, accuracy, were analyzed. Results There were 122 patients had the bone metastasis in 253 patients diagnosed breast cancer. the incidence rate was 48.2% . The thoracic part had the most incident of osseous metastasis(50.9%) ,then the vertebral body(41.8%) ,pelvis(25.4%),limbs bone (14. 5 %), skull and the other parts(9. 1%). The sensitivity, specialty, accuracy of 99mTc-MDP bone scan in determining osseuous metastasis were 93.2% 、90. 7% 、91.3% respectively;The sensitivity, specialty,accuracy of CT in the detection of cancer recurrence were 58. 2% 、87.8% 、73.5% respectively in CT scan.When combining 99mTc-MDP bone scan with CT scan,they were 93.4% 、91.6% 、92.5% respectively. Conclusion The incidence rate of osseous metastasis is very high for the breast cancer patients, and the incidence of the osseous metastasis has definite rules and features. the combination of CT and 99mTc-MDP in the follow-up studies of the breast cancer patients previously treated with both mastectomy and chemotherapy can obtain the higher sensitivity, specialty and accuracy, making a significant contribution to the value of clinical application.%目的 探讨99mTc-MDP骨显像联合CT在乳腺癌术后早期随访中,检测其复发及转移临床价值.方法 对253例术后病理确诊的乳腺癌患者一年后分别进行99mTc-MDP骨显像、CT扫描,计算灵敏度、特异性、准确性以及分析骨转移的特点.结果 253例乳腺癌全身骨显像中,发现复发或转移者122例,发生率为48.2%,99mTc-MDP发

  8. Short-term precision assessment of trabecular bone score and bone mineral density using dual-energy X-ray absorptiometry with different scan modes: an in vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Poloni, Alessandro; Messina, Carmelo; Petrini, Marcello [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Sconfienza, Luca Maria; Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy); Papini, Giacomo Davide Edoardo; Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Ulivieri, Fabio Massimo [IRCCS Fondazione Ca' Granda Ospedale Maggiore Policlinico, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Servizio di Medicina Nucleare, Milano (Italy)

    2015-07-15

    We estimated the in vivo reproducibility of trabecular bone score (TBS) from dual-energy X-ray absorptiometry (DXA) using different imaging modes to be compared to that of bone mineral density (BMD). We enrolled 30 patients for each imaging mode: fast-array, array, high definition. Each patient underwent two DXA examinations with in-between repositioning. BMD and TBS were obtained according to the International Society for Clinical Densitometry guidelines. The coefficient of variation (CoV) was calculated as the ratio between root mean square standard deviation and mean, percent least significant change (LSC) as 2.77 x CoV, reproducibility as the complement to 100 % LSC. Fast-array imaging mode resulted in 0.8 % CoV and 2.1 % LSC for BMD, 1.9 % and 5.3 % for TBS, respectively; array imaging mode resulted in 0.7 % and 2.0 % for BMD, 1.9 % and 5.2 %, for TBS; high-definition imaging mode resulted in 0.7 % and 2.0 %, for BMD; 2.0 % and 5.4 % for TBS, respectively. Reproducibility of TBS (95 %) was significantly lower than that of BMD (98 %) (p < 0.012). Difference in reproducibility among the imaging modes was not significant for either BMD or TBS (p = 0.942). While TBS reproducibility was significantly lower than that of BMD, differences among imaging modes were not significant for both TBS and BMD. (orig.)

  9. Health and Safety Laboratory environmental quarterly, June 1, 1976--September 1, 1976. [Fallout radionuclides in environment

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, E.P. Jr.

    1976-10-01

    This report presents current data from the HASL environmental programs. The initial section consists of interpretive reports and notes on Sr-90 concentrations in human bone through 1975, global deposition of Sr-90 through 1975, Pu-238 in canal and river sediment from the Mound Laboratory area, and trace metals in atmospheric deposition. Subsequent sections include tabulations of radionuclide levels in stratospheric air; lead and radionuclides in surface air; Sr-90 in deposition, milk, diet and tap water. A bibliography of recent selected publications related to environmental studies is also included. (auth)

  10. Microbial Transformations of Actinides and Other Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Francis,A.J.; Dodge, C. J.

    2009-01-07

    Microorganisms can affect the stability and mobility of the actinides and other radionuclides released from nuclear fuel cycle and from nuclear fuel reprocessing plants. Under appropriate conditions, microorganisms can alter the chemical speciation, solubility and sorption properties and thus could increase or decrease the concentrations of radionuclides in solution in the environment and the bioavailability. Dissolution or immobilization of radionuclides is brought about by direct enzymatic action or indirect non-enzymatic action of microorganisms. Although the physical, chemical, and geochemical processes affecting dissolution, precipitation, and mobilization of radionuclides have been extensively investigated, we have only limited information on the effects of microbial processes and biochemical mechanisms which affect the stability and mobility of radionuclides. The mechanisms of microbial transformations of the major and minor actinides U, Pu, Cm, Am, Np, the fission products and other radionuclides such as Ra, Tc, I, Cs, Sr, under aerobic and anaerobic conditions in the presence of electron donors and acceptors are reviewed.

  11. Targeted Radionuclide Therapy of Human Tumors

    Directory of Open Access Journals (Sweden)

    Sergey V. Gudkov

    2015-12-01

    Full Text Available Targeted radionuclide therapy is one of the most intensively developing directions of nuclear medicine. Unlike conventional external beam therapy, the targeted radionuclide therapy causes less collateral damage to normal tissues and allows targeted drug delivery to a clinically diagnosed neoplastic malformations, as well as metastasized cells and cellular clusters, thus providing systemic therapy of cancer. The methods of targeted radionuclide therapy are based on the use of molecular carriers of radionuclides with high affinity to antigens on the surface of tumor cells. The potential of targeted radionuclide therapy has markedly grown nowadays due to the expanded knowledge base in cancer biology, bioengineering, and radiochemistry. In this review, progress in the radionuclide therapy of hematological malignancies and approaches for treatment of solid tumors is addressed.

  12. MIRD radionuclide data and decay schemes

    CERN Document Server

    Eckerman, Keith F

    2007-01-01

    For all physicians, scientists, and physicists working in the nuclear medicine field, the MIRD: Radionuclide Data and Decay Schemes updated edition is an essential sourcebook for radiation dosimetry and understanding the properties of radionuclides. Includes CD Table of Contents Decay schemes listed by atomic number Radioactive decay processes Serial decay schemes Decay schemes and decay tables This essential reference for nuclear medicine physicians, scientists and physicists also includes a CD with tabulations of the radionuclide data necessary for dosimetry calculations.

  13. Microorganisms and radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshitomo [Central Research Inst. of Electric Power Industry, Abiko, Chiba (Japan)

    2002-11-01

    The influence of microorganisms on the behavior of radionuclides in the subsurface environment is one of the factors to be concerned with for the safety assessment of the geological disposal of radioactive waste. It is considered that the important microbiological aspects with respect to radionuclide behavior are biological adsorption, oxidation-reduction and complex formation between organic matter and radionuclides. These phenomena with respect to radionuclides, especially actinides, in the environment should be understood. A description of two studies, illustrating these points are presented. (author)

  14. Depiction of Nidi and Fibrovascular Zones of Osteoid Ostemas Using Gamma Correction Tc 99m HDP Pinhole Bone Scan and Conventional Radiograph, and Correlation with CT, MRI, and PVC Phantom Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Youg Whee [Sung Ae Hospital, Seoul (Korea, Republic of); Kim, Sung Hoon; Chung, Yong An; Bahk, Won Jong; Park, Jung Mee; Kang, You Mee; Choi, Woo Hee; Park, Young Ha; Sohn, Hyung Sun; Kim, Byung Ki; Chung, Soo Kyo [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2011-03-15

    For the precise imaging diagnosis of osteoid osteoma (OO), the identification of the nidus and fibrovascular zone (FVZ) is essential. However, the latter sign has received little attention because it is difficult to demonstrate. We applied the recently introduced gamma correction (GC) to depict the FVZ on pinhole bone scan (PBS), conventional radiography (CR), and computed tomography (CT). Non gamma correction MRI was also analyzed for reference. Ten patients with histologically proven diagnoses of OO were enrolled in this retrospective study. PBS, CR, and CT were processed by GC to demonstrate the nidi and FVZ as distinct yet integrating components of OO. PBS was performed using a 4mm pinhole collimator 3 h after iv injection of 925 to 1, 110 MBq (25 to 30mCi) of Tc 99m HDP, and anteroposterior and mediolateral CR and transverse CT were taken according to the standard technique. MRI sequences included T1 and T2 weighted images. For gamma correction, we utilized the Photo Correction Wizard program of ACD Photo Editor v3. 1. A team of three qualified nuclear physician radiologists, two nuclear physicians, and one MRI specialist read bone scans, radiographs, and MRIs of OO according to each specialty, and orthopaedic aspects and histology were reviewed by one qualified orthopedic surgeon and two qualified pathologists, respectively. Each observer first read the images separately with basic information about the aim of the study given and then in concert. Interpretive disagreement was settled by discussion and consensus. On pinhole scan, nidi were presented as areas of intense tracer uptake in all cases, and, importantly after GC, a thin ring like zone with lower tracer uptake became visible in seven out of ten cases. GCCR also revealed a thin lucent zone that circumscribed the nidi in six out of ten cases and GCCT in two of four cases. MRI, without GC, presented nidi with high signal in the center and a thin ring like zone with low signal in the periphery in five out

  15. Short-term precision assessment of trabecular bone score and bone mineral density using dual-energy X-ray absorptiometry with different scan modes: an in vivo study.

    Science.gov (United States)

    Bandirali, Michele; Poloni, Alessandro; Sconfienza, Luca Maria; Messina, Carmelo; Papini, Giacomo Davide Edoardo; Petrini, Marcello; Ulivieri, Fabio Massimo; Di Leo, Giovanni; Sardanelli, Francesco

    2015-07-01

    We estimated the in vivo reproducibility of trabecular bone score (TBS) from dual-energy X-ray absorptiometry (DXA) using different imaging modes to be compared to that of bone mineral density (BMD). We enrolled 30 patients for each imaging mode: fast-array, array, high definition. Each patient underwent two DXA examinations with in-between repositioning. BMD and TBS were obtained according to the International Society for Clinical Densitometry guidelines. The coefficient of variation (CoV) was calculated as the ratio between root mean square standard deviation and mean, percent least significant change (LSC) as 2.77 × CoV, reproducibility as the complement to 100% LSC. Fast-array imaging mode resulted in 0.8% CoV and 2.1% LSC for BMD, 1.9% and 5.3% for TBS, respectively; array imaging mode resulted in 0.7% and 2.0% for BMD, 1.9% and 5.2%, for TBS; high-definition imaging mode resulted in 0.7% and 2.0%, for BMD; 2.0% and 5.4% for TBS, respectively. Reproducibility of TBS (95%) was significantly lower than that of BMD (98%) (p < 0.012). Difference in reproducibility among the imaging modes was not significant for either BMD or TBS (p = 0.942). While TBS reproducibility was significantly lower than that of BMD, differences among imaging modes were not significant for both TBS and BMD. • TBS is an emerging tool for assessing BMD. • TBS reproducibility is lower than that of BMD. • Differences between imaging modes are not significant for either TBS or BMD.

  16. Measurement of bone mineral density in the tunnel regions for anterior cruciate ligament reconstruction by dual-energy X-ray absorptiometry, computed tomography scan, and the immersion technique based on Archimedes' principle.

    Science.gov (United States)

    Tie, Kai; Wang, Hua; Wang, Xin; Chen, Liaobin

    2012-10-01

    To determine, for anterior cruciate ligament (ACL) reconstruction, whether the bone mineral density (BMD) of the femoral tunnel was higher than that of the tibial tunnel, to provide objective evidence for choosing the appropriate diameter of interference screws. Two groups were enrolled. One group comprised 30 normal volunteers, and the other comprised 9 patients with ACL rupture. Dual-energy X-ray absorptiometry was used to measure the BMD of the femoral and tibial tunnel regions of the volunteers' right knees by choosing a circular area covering the screw fixation region. The knees were also scanned by spiral computed tomography (CT), and the 3-dimensional reconstruction technique was used to determine the circular sections passing through the longitudinal axis of the femoral and tibial tunnels. Grayscale CT values of the cross-sectional area were measured. Cylindrical cancellous bone blocks were removed from the femoral and tibial tunnels during the ACL reconstruction for the patients. The volumetric BMD of the bone blocks was measured using a standardized immersion technique according to Archimedes' principle. As measured by dual-energy X-ray absorptiometry, the BMD of the femoral and tibial tunnel regions was 1.162 ± 0.034 g/cm(2) and 0.814 ± 0.038 g/cm(2), respectively (P < .01). The CT value of the femoral tunnel region was 211.7 ± 11.5 Hounsfield units, and the value of the tibial tunnel region was 104.9 ± 7.4 Hounsfield units (P < .01). The volumetric BMD of the bone block from the femoral tunnel (2.80 ± 0.88 g/cm(3)) was higher than the value from the tibial tunnel (1.88 ± 0.59 g/cm(3)) (P < .01). Comparing the data between male and female patients, we found no significant difference in both femoral and tibial tunnel regions. For ACL reconstruction, the BMD of the femoral tunnel is higher than that of the tibial tunnel. This implies that a proportionally larger-diameter interference screw should be used for fixation in the proximal tibia than that

  17. Radiation-Induced Second Cancer Risk Estimates From Radionuclide Therapy

    Science.gov (United States)

    Bednarz, Bryan; Besemer, Abigail

    2017-09-01

    The use of radionuclide therapy in the clinical setting is expected to increase significantly over the next decade. There is an important need to understand the radiation-induced second cancer risk associated with these procedures. In this study the radiation-induced cancer risk in five radionuclide therapy patients was investigated. These patients underwent serial SPECT imaging scans following injection as part of a clinical trial testing the efficacy of a 131Iodine-labeled radiopharmaceutical. Using these datasets the committed absorbed doses to multiple sensitive structures were calculated using RAPID, which is a novel Monte Carlo-based 3D dosimetry platform developed for personalized dosimetry. The excess relative risk (ERR) for radiation-induced cancer in these structures was then derived from these dose estimates following the recommendations set forth in the BEIR VII report. The radiation-induced leukemia ERR was highest among all sites considered reaching a maximum value of approximately 4.5. The radiation-induced cancer risk in the kidneys, liver and spleen ranged between 0.3 and 1.3. The lifetime attributable risks (LARs) were also calculated, which ranged from 30 to 1700 cancers per 100,000 persons and were highest for leukemia and the liver for both males and females followed by radiation-induced spleen and kidney cancer. The risks associated with radionuclide therapy are similar to the risk associated with external beam radiation therapy.

  18. WBC scan

    Science.gov (United States)

    ... this test if you may have an abscess, osteomyelitis, or unexplained fever, particularly after surgery. Normal Results ... could include a liver or abdominal abscess , or osteomyelitis of the bone. Risks You will be exposed ...

  19. Radionuclide scintigraphy of the scrotum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Hyung; Park, Young Hee; Lee, Soon Jin; Lee, Sun Wha; Ko, Young Tae; Kim, Soon Yong [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1984-12-15

    Radionuclide scrotal scintigraphy with {sup 99m}Tc-pertechnetate is an easy, well established, useful and readily available technique for evaluation of acute scrotum. We studied 41 cases of radionuclide scrotal scintigraphy and the results were as follows: 1. The over all diagnostic accuracy of scrotal scintigraphy was 93% (38/41 cases). 2. Scrotal scintigraphy was very useful and accurate in differential diagnosis of epididymo-orchitis and testticular torsion in patient with acute scrotal pain and swelling, while there was some limitation in differential diagnosis of hematoma from acute epididymo-orchitis or torsion. 3. Scintigraphy of epididymo-orchitis showed increased perfusion and radioactivity in the epididymis and/or testis and its diagnosis accuracy was 90% (19/21 cases). 4. Acute testicular torsion showed normal flow in perfusion and cold defect occupying affected testis in static image, while missed torsion showed slightly increased flow in perfusion image and cold defect surrounded by an uniform rim of hyperactivity (halo sign). Diagnostic accuracy of testicular torsion was 86% (6/7 cases)

  20. 99Tcm-MDP whole body bone scan for the ancillary diagnosis of malignant fibrous histiocytoma of bone%99Tcm-MDP全身骨显像诊断骨恶性纤维组织细胞瘤的价值

    Institute of Scientific and Technical Information of China (English)

    魏玲格; 陈敏; 张芳; 郭艾楠; 解朋; 黄建敏; 刘晓梅

    2013-01-01

    Objective To investigate the usefulness of 99Tcm-MDP whole body bone scan in bone malignant fibrous histiocytoma (BMFH).Methods Fifteen patients (11 males,4 females,age ranged from 23 to 60 years,average age (50.4±12.8) years) who had documented BMFH and underwent 99Tcm-MDP whole body bone scan were retrospectively analyzed.The appearance of increased uptake,decreased uptake or defect in radioactivity on bone was considered as positive.The typical scintigraphic manifestations of BMFH were summarized and compared to other radiological imaging data.Results All 15 patients showed positive results.The lesions involved femoral in 10 cases(66.7%),46.7%(7/15) of which was distal femur.The lesions also involved sacrum,tibia,humerus,radius each in 1 case and multiple lesions in 1 case.Among 27 lesions found,63.0% (17/27) showed strong increased radioactivity together with reduced or defect area and 37.0% (10/27) showed strong increased radioactivity only.X-ray found 20 lesions.Twelve cases underwent CT and 7 cases underwent MRI.Abnormal spots showed on CT and MRI were also positive on the whole body bone scan.Conclusions The most common site of BMFH is femur,especially distal femur.BMFH lesions are presented as strong increased radioactivity together with sparse and defect area on bone scan.The whole body bone scan may be an auxiliary examination to evaluate whether there are multiple bone lesions and bone metastasis.%目的 分析骨恶性纤维组织细胞瘤(BMFH)99Tcm-MDP全身骨显像的影像特点,评价其对BMFH的诊断价值.方法 回顾性分析经手术病理证实的BMFH患者15例[男11例,女4例,年龄23~60(50.4±12.8)岁].所有患者术前均行99Tcm-MDP全身骨显像及X线检查,其中12例行CT检查,7例行MRI检查.以骨骼出现放射性异常浓聚灶或稀疏、缺损区为阳性.总结BMFH全身骨显像特点,并将显像结果与其他影像学结果进行比较.结果 15例BMFH患者全身骨显像

  1. Entrapment of Radionuclides in Nanoparticle Compositions

    DEFF Research Database (Denmark)

    2012-01-01

    such as radionuclides,for example 61Cu and 64Cu copper isotopes. The invention further relates to a novel method for loading delivery systems, such as liposome compositions, with metal entities such as radionuclides, and the use of liposomes for targeted diagnosis and treatment of a target site, such as cancerous...

  2. Bone and bone marrow function of reconstructed chest wall after surgical correction of pectus excavatum

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoh; Magara, Tatsuo; Kobayashi, Hiroaki; Ichihashi, Takumi; Hikishima, Hiroshi (Kanazawa Univ. (Japan). School of Medicine)

    1984-03-01

    Bone and bone marrow functions of the reconstructed chest wall after surgical correction of the funnel chest deformities were evaluated by scanning method. In our series, three kinds of operative procedures were employed; strut method for adult cases, sternal turnover method with and without muscle pedicle for infant cases. Bone function was scanned by sup(99m)Tc-methylene-diphosphonate and bone marrow function was evaluated by sup(99m)Tc-sulfur-colloid. For the cases undergone each surgical procedure, bone and bone marrow scan were done at short term after surgery (within 30 days), at intermediate stage (one month to 12 months), and at long term stage (beyond one year). The results were as follows: By the evaluation at the long term stage of the cases undergoing strut method, bone as well as bone marrow scan visualized normal view of the reconstructed sternum. Regarding the cases undergone sternal turnover method without muscle pedicle, or free graft implantation of the plastron, the bone scan at the long term follow-up stage showed abnormal finding, i.e. hypo-, or defect-visualization of the inverted sternum, in 11.5% of the cases. Furthermore, bone marrow scan showed abnormality in 33.3% of the cases. On the other hand, the cases undergone sternal turnover method with muscle pedicle, in which blood supply to the plastron were preserved by the connection from superior epigastric artery to internal mammary artery, showed no abnormality as far as at the long term follow-up study neither in bone scan nor bone marrow scan. However, in the evaluation at short term after surgery, 50% of the cases undergoing bone scan showed abnormality. In addition, in this stage 85.7% of the bone marrow scan showed abnormal finding. These abnormality, however, normalized within 6 months for bone scan and 12 months for bone marrow scan, in contrast to the results of the cases undergone sternal turnover without pedicle.

  3. Bone Biopsy

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging ... the limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided ...

  4. A comparison of gray scale ultrasound and radionuclide imaging for the detection of focal hepatic lesions: open shutter technique.

    Science.gov (United States)

    Zatz, L M; Gouldin, J A; Hanley, G A

    1977-06-01

    A conventional B scan ultrasound unit was modified by the addition of a specially built logarithmic amplifier and a high resolution nonstorage oscilloscope, as suggested by Taylor and Carpenter. One hundred five consecutive patients submitted for radionuclide imaging of the liver were examined with ultrasound using a standardized scanning system. The ultrasound technique produced scans that were technically poor or inadequate in 37 per cent of the patients studied. In the studies in which there has been confirmation, the ultrasound diagnosis was accurate in 73 per cent and the radionuclide diagnosis was correct in 83 per cent. The combined accuracy of the two studies was 93 per cent. In 11 patients, ultrasound more clearly defined the lesions that were demonstrated by both techniques or demonstrated the nature of suspicious or equivocal areas on the radionuclide images. In 48 patients, the radionuclide scan imaged the liver more completely or demonstrated lesions more clearly than did the ultrasound examination. This specific approach to ultrasound gray scale imaging appears to be a valuable supplemental tool to radionuclide imaging, but at its present stage of development cannot replace it as a routine screening technique for hepatic disease.

  5. Role of gallium and bone scintigraphy in disseminated coccidioidomycosis

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, A.J.; Braunstein, P.; Pais, M.J.

    1984-09-01

    The osseous lesions of disseminated coccidioidomycosis may be detected by bone but not by gallium scintigraphy or vice versa. This case emphasizes the need for performing both bone and gallium scans to avoid missing potentially serious bone lesions.

  6. MRI Scans

    Science.gov (United States)

    Magnetic resonance imaging (MRI) uses a large magnet and radio waves to look at organs and structures inside your body. Health care professionals use MRI scans to diagnose a variety of conditions, from ...

  7. Imaging of Pelvic Bone Metastasis from Malignant Phyllodes Breast Tumor

    OpenAIRE

    Nguyen, Ba D.

    2015-01-01

    The author reports a patient with a malignant phyllodes breast tumor, who then had a ten-year disease free interval before she developed a left pelvic bone metastasis and soft tissue invasion. Cross-sectional and radionuclide imaging of its musculoskeletal metastasis is presented. Literature concerning bone metastasis from phyllodes tumor is also briefly reviewed and discussed, along with its epidemiology.

  8. Radionuclides in surface and groundwater

    Science.gov (United States)

    Campbell, Kate M.

    2009-01-01

    Unique among all the contaminants that adversely affect surface and water quality, radioactive compounds pose a double threat from both toxicity and damaging radiation. The extreme energy potential of many of these materials makes them both useful and toxic. The unique properties of radioactive materials make them invaluable for medical, weapons, and energy applications. However, mining, production, use, and disposal of these compounds provide potential pathways for their release into the environment, posing a risk to both humans and wildlife. This chapter discusses the sources, uses, and regulation of radioactive compounds in the United States, biogeochemical processes that control mobility in the environment, examples of radionuclide contamination, and current work related to contaminated site remediation.

  9. Radionuclide diagnosis of allograft rejection

    Energy Technology Data Exchange (ETDEWEB)

    George, E.A.

    1982-10-01

    Interaction with one or more anatomical and physiopathological characteristics of the rejecting renal allograft is suggested by those radioagents utilized specifically for the diagnosis of allograft rejection. Rejection, the most common cause of declining allograft function, is frequently mimicked clinically or masked by other immediate or long term post transplant complications. Understanding of the anatomical pathological features and kinetics of rejection and their modification by immunosuppressive maintenance and therapy are important for the proper clinical utilization of these radioagents. Furthermore, in selecting these radionuclides, one has to consider the comparative availability, preparatory and procedural simplicity, acquisition and display techniques and the possibility of timely report. The clinical utilities of radiofibrinogen, /sup 99m/Tc sulfur colloid and /sup 67/Ga in the diagnosis of allograft rejection have been evaluated to a variable extent in the past. The potential usefulness of the recently developed preparations of /sup 111/In labeled autologous leukocytes and platelets are presently under investigation.

  10. Hypercalciuric Bone Disease

    Science.gov (United States)

    Favus, Murray J.

    2008-09-01

    Hypercalciuria plays an important causal role in many patients with calcium oxalate (CaOx) stones. The source of the hypercalciuria includes increased intestinal Ca absorption and decreased renal tubule Ca reabsorption. In CaOx stone formers with idiopathic hypercalciuria (IH), Ca metabolic balance studies have revealed negative Ca balance and persistent hypercalciuria in the fasting state and during low dietary Ca intake. Bone resorption may also contribute to the high urine Ca excretion and increase the risk of bone loss. Indeed, low bone mass by DEXA scanning has been discovered in many IH patients. Thiazide diuretic agents reduce urine Ca excretion and may increase bone mineral density (BMD), thereby reducing fracture risk. Dietary Ca restriction that has been used unsuccessfully in the treatment of CaOx nephrolithiasis in the past may enhance negative Ca balance and accelerate bone loss. DEXA scans may demonstrate low BMD at the spine, hip, or forearm, with no predictable pattern. The unique pattern of bone histologic changes in IH differs from other causes of low DEXA bone density including postmenopausal osteoporosis, male hypogonadal osteoporosis, and glucocorticoid-induced osteoporosis. Hypercalciuria appears to play an important pathologic role in the development of low bone mass, and therefore correction of urine Ca losses should be a primary target for treatment of the bone disease accompanying IH.

  11. Illicit Trafficking of Natural Radionuclides

    Science.gov (United States)

    Friedrich, Steinhäusler; Lyudmila, Zaitseva

    2008-08-01

    Natural radionuclides have been subject to trafficking worldwide, involving natural uranium ore (U 238), processed uranium (yellow cake), low enriched uranium (20% U 235), radium (Ra 226), polonium (Po 210), and natural thorium ore (Th 232). An important prerequisite to successful illicit trafficking activities is access to a suitable logistical infrastructure enabling an undercover shipment of radioactive materials and, in case of trafficking natural uranium or thorium ore, capable of transporting large volumes of material. Covert en route diversion of an authorised uranium transport, together with covert diversion of uranium concentrate from an operating or closed uranium mines or mills, are subject of case studies. Such cases, involving Israel, Iran, Pakistan and Libya, have been analyzed in terms of international actors involved and methods deployed. Using international incident data contained in the Database on Nuclear Smuggling, Theft and Orphan Radiation Sources (DSTO) and international experience gained from the fight against drug trafficking, a generic Trafficking Pathway Model (TPM) is developed for trafficking of natural radionuclides. The TPM covers the complete trafficking cycle, ranging from material diversion, covert material transport, material concealment, and all associated operational procedures. The model subdivides the trafficking cycle into five phases: (1) Material diversion by insider(s) or initiation by outsider(s); (2) Covert transport; (3) Material brokerage; (4) Material sale; (5) Material delivery. An Action Plan is recommended, addressing the strengthening of the national infrastructure for material protection and accounting, development of higher standards of good governance, and needs for improving the control system deployed by customs, border guards and security forces.

  12. Targeted Radionuclide Therapy of Melanoma.

    Science.gov (United States)

    Norain, Abdullah; Dadachova, Ekaterina

    2016-05-01

    An estimated 60,000 individuals in the United States and 132,000 worldwide are yearly diagnosed with melanoma. Until recently, treatment options for patients with stages III-IV metastatic disease were limited and offered marginal, if any, improvement in overall survival. The situation changed with the introduction of B-RAF inhibitors and anti-cytotoxic T-lymphocyte antigen 4 and anti-programmed cell death protein 1 immunotherapies into the clinical practice. With only some patients responding well to the immune therapies and with very serious side effects and high costs of immunotherapy, there is still room for other approaches for the treatment of metastatic melanoma. Targeted radionuclide therapy of melanoma could be divided into the domains of radioimmunotherapy (RIT), radiolabeled peptides, and radiolabeled small molecules. RIT of melanoma is currently experiencing a renaissance with the clinical trials of alpha-emitter (213)Bi-labeled and beta-emitter (188)Rhenium-labeled monoclonal antibodies in patients with metastatic melanoma producing encouraging results. The investigation of the mechanism of efficacy of melanoma RIT points at killing of melanoma stem cells by RIT and involvement of immune system such as complement-dependent cytotoxicity. The domain of radiolabeled peptides for targeted melanoma therapy has been preclinical so far, with work concentrated on radiolabeled peptide analogues of melanocyte-stimulating hormone receptor and on melanin-binding peptides. The field of radiolabeled small molecule produced radioiodinated benzamides that cross the cellular membrane and bind to the intracellular melanin. The recent clinical trial demonstrated measurable antitumor effects and no acute or midterm toxicities. We are hopeful that the targeted radionuclide therapy of metastatic melanoma would become a clinical reality as a stand-alone therapy or in combination with the immunotherapies such as anti-PD1 programmed cell death protein 1 monoclonal antibodies

  13. Radionuclides: Accumulation and Transport in Plants.

    Science.gov (United States)

    Gupta, D K; Chatterjee, S; Datta, S; Voronina, A V; Walther, C

    Application of radioactive elements or radionuclides for anthropogenic use is a widespread phenomenon nowadays. Radionuclides undergo radioactive decays releasing ionizing radiation like gamma ray(s) and/or alpha or beta particles that can displace electrons in the living matter (like in DNA) and disturb its function. Radionuclides are highly hazardous pollutants of considerable impact on the environment, food chain and human health. Cleaning up of the contaminated environment through plants is a promising technology where the rhizosphere may play an important role. Plants belonging to the families of Brassicaceae, Papilionaceae, Caryophyllaceae, Poaceae, and Asteraceae are most important in this respect and offer the largest potential for heavy metal phytoremediation. Plants like Lactuca sativa L., Silybum marianum Gaertn., Centaurea cyanus L., Carthamus tinctorius L., Helianthus annuus and H. tuberosus are also important plants for heavy metal phytoremediation. However, transfer factors (TF) of radionuclide from soil/water to plant ([Radionuclide]plant/[Radionuclide]soil) vary widely in different plants. Rhizosphere, rhizobacteria and varied metal transporters like NRAMP, ZIP families CDF, ATPases (HMAs) family like P1B-ATPases, are involved in the radio-phytoremediation processes. This review will discuss recent advancements and potential application of plants for radionuclide removal from the environment.

  14. Bone marrow metastases from alveolar rhabdomyosarcoma with impressive FDG PET/CT finding but less-revealing bone scintigraphy.

    Science.gov (United States)

    Yang, Jigang; Zhen, Lishi; Zhuang, Hongming

    2013-12-01

    An 18F-FDG PET/CT scan was performed in a 26-year-old man with a known alveolar rhabdomyosarcoma for staging. The PET/CT scan showed abnormally increased FDG activity involving almost all bones in the imaged regions. In contrast, 99mTc-MDP whole-body bone scan demonstrated only very limited bone metastases.

  15. TRANSPORT OF RADIONUCLIDES ALONG MARINE FOODCHAIN

    Institute of Scientific and Technical Information of China (English)

    吴国斌; 余君岳; 等

    1995-01-01

    A compartment model is employed to calculate the radionuclide concentrations in the ocean currents for a nuclear accient scenario where the long-lived 137 Cs is totally discharged into the sea.The radionuclide concentrations in both the waters of Daya Bay and the adjacent south China Sea are considered.Using the concentration factors for the marine organisms:fish,crustacea and mollusca,their radionuclide concentrations are also estimated.In this way,the whole body radiation doses received by an individual due to ingestion of marine organisms from the Daya Bay and the South China Sea are calculated.

  16. 2008 LANL radionuclide air emissions report

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David P.

    2009-06-01

    The emissions of radionuclides from Department of Energy Facilities such as Los Alamos National Laboratory (LANL) are regulated by the Amendments to the Clean Air Act of 1990, National Emissions Standards for Hazardous Air Pollutants (40 CFR 61 Subpart H). These regulations established an annual dose limit of 10 mrem to the maximally exposed member of the public attributable to emissions of radionuclides. This document describes the emissions of radionuclides from LANL and the dose calculations resulting from these emissions for calendar year 2008. This report meets the reporting requirements established in the regulations.

  17. 2009 LANL radionuclide air emissions report

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David P.

    2010-06-01

    The emissions of radionuclides from Department of Energy Facilities such as Los Alamos National Laboratory (LANL) are regulated by the Amendments to the Clean Air Act of 1990, National Emissions Standards for Hazardous Air Pollutants (40 CFR 61 Subpart H). These regulations established an annual dose limit of 10 mrem to the maximally exposed member of the public attributable to emissions of radionuclides. This document describes the emissions of radionuclides from LANL and the dose calculations resulting from these emissions for calendar year 2009. This report meets the reporting requirements established in the regulations.

  18. 2010 LANL radionuclide air emissions report /

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David P.

    2011-06-01

    The emissions of radionuclides from Department of Energy Facilities such as Los Alamos National Laboratory (LANL) are regulated by the Amendments to the Clean Air Act of 1990, National Emissions Standards for Hazardous Air Pollutants (40 CFR 61 Subpart H). These regulations established an annual dose limit of 10 mrem to the maximally exposed member of the public attributable to emissions of radionuclides. This document describes the emissions of radionuclides from LANL and the dose calculations resulting from these emissions for calendar year 2010. This report meets the reporting requirements established in the regulations.

  19. Radiation safety requirements for radionuclide laboratories

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The guide lays down the requirements for laboratories and storage rooms in which radioactive substances are used or stored as unsealed sources. In addition, some general instructions concerning work in radionuclide laboratories are set out.

  20. Long lived gamma emitting radionuclides in incense.

    Science.gov (United States)

    Alrefae, Tareq

    2013-10-01

    A study of long-lived gamma emitters in incense was performed. The incense samples originated from seven different countries, and the investigated radionuclides were Ra, Ra, and K. Gamma spectroscopy revealed the presence of all three investigated radionuclides in all samples. Interestingly, the activity concentrations revealed a clear bimodal distribution that distinguished samples that were natural incense from others that were processed incense. The activity concentrations in the latter group were found to be one order of magnitude greater than in the former group. Consequently, the estimated annual effective dose from the latter group was one order of magnitude higher than that of the former group. Nonetheless, the doses from both groups were found to be some three orders of magnitude less than the average worldwide exposure to inhaled natural radionuclides. This finding suggests the radiological safety of incense for the investigated radionuclides.

  1. 49 CFR 173.433 - Requirements for determining basic radionuclide values, and for the listing of radionuclides on...

    Science.gov (United States)

    2010-10-01

    ... radionuclide values, and for the listing of radionuclides on shipping papers and labels. (a) For individual radionuclides listed in the table in § 173.435 and § 173.436: (1) A1 and A2 values are given in the table in... values, and for the listing of radionuclides on shipping papers and labels. 173.433 Section...

  2. Livermore Accelerator Source for Radionuclide Science (LASRS)

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Scott [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bleuel, Darren [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Johnson, Micah [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rusnak, Brian [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Soltz, Ron [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tonchev, Anton [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-05

    The Livermore Accelerator Source for Radionuclide Science (LASRS) will generate intense photon and neutron beams to address important gaps in the study of radionuclide science that directly impact Stockpile Stewardship, Nuclear Forensics, and Nuclear Material Detection. The co-location of MeV-scale neutral and photon sources with radiochemical analytics provides a unique facility to meet current and future challenges in nuclear security and nuclear science.

  3. [Bone metastases treated with radiopharmaceuticals].

    Science.gov (United States)

    Giammarile, Francesco

    2013-11-01

    The administration of a radionuclide in unsealed source whose radiation will destroy cells that have selectively accumulated product is called radiometabolic therapy. The management of bone pain is a major problem, particularly in cases of breast or prostate where the presence of metastases can remain compatible with long-term survival of cancer patients. In this context, the radiometabolic therapy reduces the pain secondary to bone metastases, in association or not with analgesics. This technique is rarely prescribed as first-line. It can also be combined with external beam radiotherapy or chemotherapy, if clinical conditions permit (due to the increased risk of hematologic toxicity). In this setting, the currently used substances are Metastron® and Quadramet®. Recently, a new product, radium chloride (or Alpharadin®) has shown efficacy in bone metastases from prostate cancer, particularly in terms of bone pain palliation, but also of increased overall survival. In addition, this product has virtually no hematologic toxicity.

  4. Development of scan analysis techniques employing a small computer. Final report, February 1, 1963--July 31, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D.E.

    1976-08-05

    During the thirteen year duration of this contract the goal has been to develop and apply computer based analysis of radionuclide scan data so as to make available improved diagnostic information based on a knowledge of localized quantitative estimates of radionuclide concentration. Results are summarized. (CH)

  5. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  6. Migration of radionuclides through a river system

    Energy Technology Data Exchange (ETDEWEB)

    Matsunaga, Takeshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-03-01

    Migration behavior of several atmospherically-derived radionuclides in a river watershed was studied. A main interest was in their relocation from the ground soil of the watershed to a downstream region through a river. Studied radionuclides are: {sup 137}Cs generated by weapon tests in the atmosphere; {sup 210}Pb and {sup 7}Be of naturally occurring radionuclides; {sup 137}Cs, {sup 90}Sr, {sup 239,240}Pu and {sup 241}Am released by the Chernobyl nuclear power plant accident. Dominance of the form in suspended solid in river water (particulate form) was qualified for the radionuclides in the Kuji river watershed. An importance of discharge in flooding was also confirmed. A historical budget analysis for weapon test derived {sup 137}Cs was presented for the Hi-i river watershed and its accompanied lake sediment (Lake Shinji). The work afforded a scheme of a fate of {sup 137}Cs after falling on the ground soil and on the lake surface. Several controlling factors, which can influence on the chemical form of radionuclides discharged to a river, were also investigated in the vicinity of the Chernobyl nuclear power plant. A special attention was paid on the association of the radionuclides with dissolved species in water. Preferential association of Pu and Am isotopes to a large molecular size of dissolved matrices, probably of humic substances, was suggested. (author)

  7. Vertical distribution of natural radionuclides in soils

    Directory of Open Access Journals (Sweden)

    Lozano J. C.

    2012-04-01

    Full Text Available Low-level alpha spectrometry techniques using semiconductor detectors (PIPS and liquid scintillation counters (LKB Quantulus 1220™ were used in order to determine the activity concentration of 238U, 232Th, 234U, 230Th, 226Ra, and 210Pb in soil samples. The soils were collected from an old disused uranium mine located in southwest Spain. The soils were selected with different levels of influence from the installation, in such a way that they had different levels of radioactive contamination. The vertical profiles in the soils (down to 40 cm depth were studied in order to evaluate the vertical distribution of the natural radionuclides. The possible contamination of subsurface waters depends strongly on vertical migration, and the transfer to plants (herbs, shrubs, and trees also will depend on the distribution of the radionuclides in the root zone. The study of the activity ratios between radionuclides belonging to the same series allowed us to assess the differing behaviour of the radionuclides involved. The vertical profiles for these radionuclides were different at each sampling point, showing the local impact of the installation. However, the profiles per point were similar for the long-lived radionuclides of the 238TJ series (238U, 234U, 230Th, and 226Ra. Also, a major disequilibrium was observed between 210Pb and 226Ra in the surface layer, due to 222Rn emanation and subsequent surface deposition of 210Pb.

  8. Radionuclide Air Emissions Report for 2012

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Linnea [Ernest Orlando Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2013-05-01

    Berkeley Lab operates facilities where radionuclides are produced, handled, store d, and potentially emitted . These facilities are subject to the EPA radioactive air emission regulations in 40 CFR 61, Subpart H (EPA 1989a). Radionuclides may be emitted from stacks or vents on buildings where radionuclide production or use is authorized or they may be emitted as diffuse sources. In 2012, all Berkeley Lab sources were minor sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]) . These minor sources include d about 140 stack sources and no diffuse sources . T here were no unplanned airborne radionuclide emissions from Berkeley Lab operations . Emissions from minor sources were measured by sampling or monitoring or were calculated based on quantities used, received for use, or produced during the year. Using measured and calculated emissions, and building- specific and common parameters, Laboratory personnel applied the EPA -approved computer code s, CAP88-PC and COMPLY , to calculate doses to the maximally exposed individual (MEI) at any offsite point where there is a residence, school, business, or office. Because radionuclides are used at three noncontiguous locations (the main site, Berkeley West Bio center, and Joint BioEnergy Institute), three different MEIs were identified.

  9. Solubility limits on radionuclide dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Kerrisk, J.F.

    1984-12-31

    This paper examines the effects of solubility in limiting dissolution rates of a number of important radionuclides from spent fuel and high-level waste. Two simple dissolution models were used for calculations that would be characteristics of a Yucca Mountain repository. A saturation-limited dissolution model, in which the water flowing through the repository is assumed to be saturated with each waste element, is very conservative in that it overestimates dissolution rates. A diffusion-limited dissolution model, in which element-dissolution rates are limited by diffusion of waste elements into water flowing past the waste, is more realistic, but it is subject to some uncertainty at this time. Dissolution rates of some elements (Pu, Am, Sn, Th, Zr, Sm) are always limited by solubility. Dissolution rates of other elements (Cs, Tc, Np, Sr, C, I) are never solubility limited; their release would be limited by dissolution of the bulk waste form. Still other elements (U, Cm, Ni, Ra) show solubility-limited dissolution under some conditions. 9 references, 3 tables.

  10. Radionuclides in marine mammals off the Portuguese coast

    Energy Technology Data Exchange (ETDEWEB)

    Malta, Margarida [Instituto Tecnologico e Nuclear, Departamento de Proteccao Radiologica e Seguranca Nuclear, E.N. 10, 2686-953 Sacavem (Portugal); Carvalho, Fernando P., E-mail: carvalho@itn.p [Instituto Tecnologico e Nuclear, Departamento de Proteccao Radiologica e Seguranca Nuclear, E.N. 10, 2686-953 Sacavem (Portugal)

    2011-05-15

    Radionuclide analyses were performed in tissue samples including muscle, gonad, liver, mammary gland, and bone of marine mammals stranded on the Portuguese west coast during January-July 2006. Tissues were collected from seven dolphins (Delphinus delphis and Stenella coeruleoalba) and one pilot whale (Globicephala sp.). Samples were analyzed for {sup 210}Po and {sup 210}Pb by alpha spectrometry and for {sup 137}Cs and {sup 40}K by gamma spectrometry. Po-210 concentrations in common dolphin's muscle (D. delphis) averaged 56 {+-} 32 Bq kg{sup -1} wet weight (w.w.), while {sup 210}Pb averaged 0.17 {+-} 0.07 Bq kg{sup -1} w.w., {sup 137}Cs averaged 0.29 {+-} 0.28 Bq kg{sup -1} w.w., and {sup 40}K 129 {+-} 48 Bq kg{sup -1} w.w. Absorbed radiation doses due to these radionuclides for the internal organs of common dolphins were computed and attained a 1.50 {mu}Gy h{sup -1} on a whole body basis. {sup 210}Po was the main contributor to the weighted absorbed dose, accounting for 97% of the dose from internally accumulated radionuclides. These computed radiation doses in dolphins are compared to radiation doses from {sup 210}Po and other radionuclides reported for human tissues. Due to the high {sup 210}Po activity concentration in dolphins, the internal radiation dose in these marine mammals is about three orders of magnitude higher than in man. - Highlights: {yields} In marine mammals the highest activity concentrations were those of {sup 40}K and {sup 210}Po. {yields} Absorbed radiation doses in dolphin tissues attained 1.50 mGy h{sup -1} on a whole body basis. {yields} Po-210 was the main contributor (97%) to the internal absorbed radiation dose. {yields} The high {sup 210}Po concentration in the marine mammal's tissues is due to food chain transfer. {yields} The absorbed radiation dose in dolphins is three orders of magnitude higher than in man.

  11. A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions

    Science.gov (United States)

    Lanconelli, N.; Pacilio, M.; Lo Meo, S.; Botta, F.; Di Dia, A.; Torres Aroche, L. A.; Coca Pérez, M. A.; Cremonesi, M.

    2012-01-01

    The increasing availability of SPECT/CT devices with advanced technology offers the opportunity for the accurate assessment of the radiation dose to the biological target volume during radionuclide therapy. Voxel dosimetry can be performed employing direct Monte Carlo radiation transport simulations, based on both morphological and functional images of the patient. On the other hand, for voxel dosimetry calculations the voxel S value method can be considered an easier approach than patient-specific Monte Carlo simulations, ensuring a good dosimetric accuracy at least for anatomic regions which are characterized by uniform density tissue. However, this approach has been limited because of the lack of tabulated S values for different voxel dimensions and radionuclides. The aim of this work is to provide a free dataset of values which can be used for voxel dosimetry in targeted radionuclide studies. Seven different radionuclides (89Sr, 90Y, 131I, 153Sm, 177Lu, 186Re, 188Re), and 13 different voxel sizes (2.21, 2.33, 2.4, 3, 3.59, 3.9, 4, 4.42, 4.8, 5, 6, 6.8 and 9.28 mm) are considered. Voxel S values are calculated performing simulations of monochromatic photon and electron sources in two different homogeneous tissues (soft tissue and bone) with DOSXYZnrc code, and weighting the contributions on the basis of the radionuclide emission spectra. The outcomes are validated by comparison with Monte Carlo simulations obtained with other codes (PENELOPE and MCNP4c) performing direct simulation of the radionuclide emission spectra. The differences among the different Monte Carlo codes are of the order of a few per cent when considering the source voxel and the bremsstrahlung tail, whereas the highest differences are observed at a distance close to the maximum continuous slowing down approximation range of electrons. These discrepancies would negligibly affect dosimetric assessments. The dataset of voxel S values can be freely downloaded from the website www.medphys.it.

  12. A free database of radionuclide voxel S values for the dosimetry of nonuniform activity distributions.

    Science.gov (United States)

    Lanconelli, N; Pacilio, M; Lo Meo, S; Botta, F; Di Dia, A; Aroche, A Torres; Pérez, M A Coca; Cremonesi, M

    2012-01-21

    The increasing availability of SPECT/CT devices with advanced technology offers the opportunity for the accurate assessment of the radiation dose to the biological target volume during radionuclide therapy. Voxel dosimetry can be performed employing direct Monte Carlo radiation transport simulations, based on both morphological and functional images of the patient. On the other hand, for voxel dosimetry calculations the voxel S value method can be considered an easier approach than patient-specific Monte Carlo simulations, ensuring a good dosimetric accuracy at least for anatomic regions which are characterized by uniform density tissue. However, this approach has been limited because of the lack of tabulated S values for different voxel dimensions and radionuclides. The aim of this work is to provide a free dataset of values which can be used for voxel dosimetry in targeted radionuclide studies. Seven different radionuclides (89Sr, 90Y, 131I, 153Sm, 177Lu, 186Re, 188Re), and 13 different voxel sizes (2.21, 2.33, 2.4, 3, 3.59, 3.9, 4, 4.42, 4.8, 5, 6, 6.8 and 9.28 mm) are considered. Voxel S values are calculated performing simulations of monochromatic photon and electron sources in two different homogeneous tissues (soft tissue and bone) with DOSXYZnrc code, and weighting the contributions on the basis of the radionuclide emission spectra. The outcomes are validated by comparison with Monte Carlo simulations obtained with other codes (PENELOPE and MCNP4c) performing direct simulation of the radionuclide emission spectra. The differences among the different Monte Carlo codes are of the order of a few per cent when considering the source voxel and the bremsstrahlung tail, whereas the highest differences are observed at a distance close to the maximum continuous slowing down approximation range of electrons. These discrepancies would negligibly affect dosimetric assessments. The dataset of voxel S values can be freely downloaded from the website www.medphys.it.

  13. Bone within a bone

    Energy Technology Data Exchange (ETDEWEB)

    Williams, H.J.; Davies, A.M. E-mail: wendy.turner@roh.nhs.uk; Chapman, S

    2004-02-01

    The 'bone within a bone' appearance is a well-recognized radiological term with a variety of causes. It is important to recognize this appearance and also to be aware of the differential diagnosis. A number of common conditions infrequently cause this appearance. Other causes are rare and some remain primarily of historical interest, as they are no longer encountered in clinical practice. In this review we illustrate some of the conditions that can give the bone within a bone appearance and discuss the physiological and pathological aetiology of each where known.

  14. Tissue radionuclide concentrations in water birds and upland birds on the Hanford Site (USA) from 1971-2009

    Energy Technology Data Exchange (ETDEWEB)

    Delistraty, Damon, E-mail: DDEL461@ecy.wa.gov [Washington State Department of Ecology, N. 4601 Monroe Street, Spokane, WA 99205-1295 (United States); Van Verst, Scott [Washington State Department of Health, Olympia, WA (United States)

    2011-08-15

    Historical operations at the Hanford Site (Washington State, USA) have released a wide array of non-radionuclide and radionuclide contaminants into the environment. As a result, there is a need to characterize contaminant effects on site biota. Within this framework, the main purpose of our study was to evaluate radionuclide concentrations in bird tissue, obtained from the Hanford Environmental Information System (HEIS). The database was sorted by avian group (water bird vs. upland bird), radionuclide (over 20 analytes), tissue (muscle, bone, liver), location (onsite vs. offsite), and time period (1971-1990 vs. 1991-2009). Onsite median concentrations in water birds were significantly higher (Bonferroni P < 0.05) than those in onsite upland birds for Cs-137 in muscle (1971-1990) and Sr-90 in bone (1991-2009), perhaps due to behavioral, habitat, or trophic species differences. Onsite median concentrations in water birds were higher (borderline significance with Bonferroni P = 0.05) than those in offsite birds for Cs-137 in muscle (1971-1990). Onsite median concentrations in the earlier time period were significantly higher (Bonferroni P < 0.05) than those in the later time period for Co-60, Cs-137, Eu-152, and Sr-90 in water bird muscle and for Cs-137 in upland bird muscle tissue. Median concentrations of Sr-90 in bone were significantly higher (Bonferroni P < 0.05) than those in muscle for both avian groups and both locations. Over the time period, 1971-2009, onsite median internal dose was estimated for each radionuclide in water bird and upland bird tissues. However, a meaningful dose comparison between bird groups was not possible, due to a dissimilar radionuclide inventory, mismatch of time periods for input radionuclides, and lack of an external dose estimate. Despite these limitations, our results contribute toward ongoing efforts to characterize ecological risk at the Hanford Site. - Highlights: > Radionuclides evaluated in bird tissues on the Hanford Site

  15. Head CT scan

    Science.gov (United States)

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... hold your breath for short periods. A complete scan usually take only 30 seconds to a few ...

  16. Accounting for beta-particle energy loss to cortical bone via paired-image radiation transport (PIRT).

    Science.gov (United States)

    Shah, Amish P; Rajon, Didier A; Patton, Phillip W; Jokisch, Derek W; Bolch, Wesley E

    2005-05-01

    Current methods of skeletal dose assessment in both medical physics (radionuclide therapy) and health physics (dose reconstruction and risk assessment) rely heavily on a single set of bone and marrow cavity chord-length distributions in which particle energy deposition is tracked within an infinite extent of trabecular spongiosa, with no allowance for particle escape to cortical bone. In the present study, we introduce a paired-image radiation transport (PIRT) model which provides a more realistic three-dimensional (3D) geometry for particle transport in the skeletal site at both microscopic and macroscopic levels of its histology. Ex vivo CT scans were acquired of the pelvis, cranial cap, and individual ribs excised from a 66-year male cadaver (BMI of 22.7 kg m(-2)). For the three skeletal sites, regions of trabecular spongiosa and cortical bone were identified and segmented. Physical sections of interior spongiosa were taken and subjected to microCT imaging. Voxels within the resulting microCT images were then segmented and labeled as regions of bone trabeculae, endosteum, active marrow, and inactive marrow through application of image processing algorithms. The PIRT methodology was then implemented within the EGSNRC radiation transport code whereby electrons of various initial energies are simultaneously tracked within both the ex vivo CT macroimage and the CT microimage of the skeletal site. At initial electron energies greater than 50-200 keV, a divergence in absorbed fractions to active marrow are noted between PIRT model simulations and those estimated under existing techniques of infinite spongiosa transport. Calculations of radionuclide S values under both methodologies imply that current chord-based models may overestimate the absorbed dose to active bone marrow in these skeletal sites by 0% to 27% for low-energy beta emitters (33P, 169Er, and 177Lu), by approximately 4% to 49% for intermediate-energy beta emitters (153Sm, 186Re, and 89Sr), and by

  17. Bone regeneration with cultured human bone grafts

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, T.; Nakajima, H. [Nara Medical Univ., Kashihara City (Japan). Dept. of Pathology; Nara Medical Univ., Kashihara City (Japan). Dept. of Orthopedic Surgery; Ohgushi, H.; Ueda, Y.; Takakura, Y. [Nara Medical Univ., Kashihara City (Japan). Dept. of Orthopedic Surgery; Uemura, T.; Tateishi, T. [National Inst. for Advanced Interdisciplinary Research (NAIR), Ibaraki (Japan). Tsukuba Research Center; Enomoto, Y.; Ichijima, K. [Nara Medical Univ., Kashihara City (Japan). Dept. of Pathology

    2001-07-01

    From 73 year old female patient, 3 ml of bone marrow was collected from the ilium. The marrow was cultured to concentrate and expand the marrow mesenchymal cells on a culture dish. The cultured cells were then subculturedeither on another culture dish or in porous areas of hydroxyapatite ceramics in the presence of dexamethasone and beta-glycerophosphate (osteo genic medium). The subculturedtissues on the dishes were analyzed by scanning electron microscopy (SEM), and subculturedtissues in the ceramics were implanted intraperitoneally into athymic nude mice. Vigorous growth of spindle-shaped cells and a marked formation of bone matrix beneath the cell layers was observed on the subculture dishes by SEM. The intraperitoneally implanted ceramics with cultured tissues revealed thick layer of lamellar bone together with active osteoblasts lining in many pore areas of the ceramics after 8 weeks. The in vitro bone formations on the culture dishes and in vivo bone formation in porous ceramics were detected. These results indicate that we can assemble an in vitro bone/ceramic construct, and due to the porous framework of the ceramic, the construct has osteogenic potential similar to that of autologous cancellous bone. A significant benefit of this method is that the construct can be made with only a small amount of aspirated marrow cells from aged patients with little host morbidity. (orig.)

  18. Fat mass measured by DXA varies with scan velocity

    DEFF Research Database (Denmark)

    Black, Eva; Petersen, Liselotte; Kreutzer, Martin

    2002-01-01

    To study the influence of scan velocities of DXA on the measured size of fat mass, lean body mass, bone mineral content and density, and total body weight.......To study the influence of scan velocities of DXA on the measured size of fat mass, lean body mass, bone mineral content and density, and total body weight....

  19. Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    2012-02-16

    The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N{sup 4}-methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the

  20. Radionuclide Mobility at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Smith, D; Rose, T; Glascoe, L; Steefel, C; Zavarin, M

    2003-11-13

    Underground nuclear tests conducted at the Nevada Test Site (NTS) are characterized by abundant fission product and actinide source terms. Included are {sup 99}Tc and other soluble radionuclides ({sup 3}H, {sup 14}C, {sup 36}Cl, {sup 85}Kr, and {sup 129}I), which are presumably mobile in groundwater and potentially toxic to down-gradient receptors. NTS provides the Office of Civilian Radioactive Waste Management (OCRWM) with an analog of the release of these radionuclides from a nuclear waste repository in the absence of engineered barriers. The investigation described in this report synthesizes a substantial body of data collected on the identity and distribution of soluble radionuclides at field scales over distances of hundreds of meters, for durations up to 40 years, and under hydrogeologic conditions very similar to the proposed geological repository at Yucca Mountain. This body of data is complemented by laboratory transport studies and a synthesis of recent modeling investigations from the NTS, with an emphasis on the ongoing Yucca Mountain Program (YMP) efforts. Overall, understanding the controls of radionuclide mobility associated with these nuclear tests will provide insight into the repository's future performance as well as bounds and calibrations for the numerical predictions of long-term radionuclide releases and migration.

  1. Radionuclide Retention in Concrete Waste Forms

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Bovaird, Chase C.; Wellman, Dawn M.; Wood, Marcus I.

    2010-09-30

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how waste form performance is affected by the full range of environmental conditions within the disposal facility; the process of waste form aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of waste form aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the waste forms come in contact with groundwater. The information presented in the report provides data that 1) quantify radionuclide retention within concrete waste form materials similar to those used to encapsulate waste in the Low-Level Waste Burial Grounds (LLBG); 2) measure the effect of concrete waste form properties likely to influence radionuclide migration; and 3) quantify the stability of uranium-bearing solid phases of limited solubility in concrete.

  2. Radionuclide Retention in Concrete Wasteforms - FY13

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Michelle MV; Golovich, Elizabeth C.; Wellman, Dawn M.; Crum, Jarrod V.; Lapierre, Robert; Dage, Denomy C.; Parker, Kent E.; Cordova, Elsa A.

    2013-10-15

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. Data collected throughout the course of this work will be used to quantify the efficacy of concrete wasteforms, similar to those used in the disposal of low-level waste and mixed low-level waste, for the immobilization of key radionuclides (i.e., uranium, technetium, and iodine). Data collected will also be used to quantify the physical and chemical properties of the concrete affecting radionuclide retention.

  3. Distribution of radionuclides in bayer process

    Energy Technology Data Exchange (ETDEWEB)

    Cuccia, Valeria; Oliveira, Arno H. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Rocha, Zildete [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Quimica e Radioquimica], E-mail: rochaz@cdtn.br

    2007-07-01

    Natural occurring radionuclides are present in many natural resources. Human activities may enhance concentrations of radionuclides and/or enhance potential of exposure to naturally occurring radioactive material (NORM). The industrial residues containing radionuclides have been receiving a considerable global attention, because of the large amounts of NORM containing wastes and the potential long term risks of long-lived radionuclides. Included in this global concern, this work focuses on the characterization of radioactivity in bauxite and samples of intermediate phases of Bayer process for alumina production, including the end product - alumina - and its main residue - red mud. The analytical techniques used were gamma spectrometry (HPGe detector) and Neutron Activation Analysis. It was found that the bauxite is the major contributor to radioactivity in Bayer process. It has activities of 37+-12 Bq.kg{sup -1} for {sup 238}U and 154+-16 Bq.kg{sup -1} for {sup 232}Th. The intermediate phases and the end product do not carry significant activity, desirable characteristic from the health physics point of view. Sand and red mud carry most part of radionuclides, and the concentrations are higher in the red mud than in the sand. Thus, these solid residues present activities concentrations enhanced, when compared to bauxite. (author)

  4. Accumulation of radionuclides by lichen symbionts

    Energy Technology Data Exchange (ETDEWEB)

    Nifontova, M.G.; Kulikov, N.V. (AN SSSR, Sverdlovsk. Inst. Ehkologii Rastenij i Zhivotnykh)

    1983-01-01

    The aim of investigation is the quantitative estimation of ability and role of separate symbionts in the accumulation of radionuclides. As investigation volumes, durably cultivated green lichen alga Trebouxia erici and lichen fungi extracted from Cladonia rangiferina, Parmelia caperata and Acarospora fuscata are used. The accumulation of radioactive isotopes with fungi and seaweeds is estimated according to accumulation coefficients (AC) which are the ratio of radiation concentration in plants and agarized medium. Radionuclide content (/sup 90/Sr and /sup 137/Cs) is determined radiometrically. A special series of experiments is done to investigate radionuclide accumulation dependences with lichen seaweed and fungi on light conditions. It is shown that both symbionts of lichen-seaweed and fungus take part in the accumulation of radionuclide from outer medium (atmospheric fall-out and soil). However fungus component constituting the base of structural organization of thallus provides the greater part of radionuclides accumulated by the plant. Along with this the violation of viability of seaweed symbionts particularly in the case of light deficiency brings about the reduction of /sup 137/Cs sorption by seaweeds and tells on the total content of radiocesium in plant thallus.

  5. 核素骨扫描与MRI对肺癌脊柱骨转移癌灶的检验分析%Radionuclide Bone Scan and MRI of the Spine Bone Metastasis ofLung Cancer foci of Tests and Analysis

    Institute of Scientific and Technical Information of China (English)

    潘伟; 欧阳寄

    2013-01-01

    目的探讨核素骨扫描与MRI检查方式在肺癌脊柱骨转移诊断与病灶检出中的临床价值。方法选取我院2008年5月~2012年8月收治的肺癌患者216例,均进行经核素骨扫描与MRI核磁共振检查。结果核素骨扫描与MRI诊断肺癌脊柱骨转移的检出率无显著差异(χ2=0.118,P>0.05)。 MRI检查肺癌脊柱骨转移的病灶检出率相比核素骨扫描方式显著提高(χ2=4.792,P<0.05)。结论核素骨扫描与MRI诊断均能够有效诊断肺癌脊柱骨转移,而核素骨扫描对肺癌脊柱骨转移病灶的检出能力相对较差,MRI相比核素骨扫描更准确,应作为肺癌脊柱骨转移的首要检查方式。

  6. Assessment of bone metastasis of breast cancer by radionuclide bone scan combined with CA15-3,CA50 and IL-8 on%放射性核素骨显像联合血清CA15-3、CA50、IL-8评价乳腺癌骨转移的临床意义

    Institute of Scientific and Technical Information of China (English)

    蒋炳辰; 张雪辉; 高永旺; 陈方旎; 肖国有; 姚少红

    2013-01-01

    目的 评价血清CA15-3 、CA50、IL-8联合放射性核素骨显像对乳腺癌患者骨转移诊断的临床意义.方法 利用SPECT/CT对乳腺癌患者进行骨骼放射性核素骨显像,应用化学发光法和放射免疫法对84例乳腺癌患者(均为女性)进行血清CA15-3、CA50、IL-8含量检测,并与34名正常人(均为女性)进行相关对比分析.结果 乳腺癌患者骨转移的血清CA15-3、CA50、IL-8含量水平明显高于正常人组(P<0.01),乳腺癌骨转移组灶数>2个的肿瘤标志物水平明显高于灶数≤2个的肿瘤标志物水平(P<0.01).结论 在进行放射性SPECT/CT显像同时,进行血清CA15-3、CA50和IL-8的检测,能够尽早发现乳腺癌骨转移.

  7. Bone scintigraphy and metabolic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Mari' , C.; Catafau, A.; Carrio' , I. [Hospital de Sant Pau, Barcelone (Spain). Serv. of Nuclear Medicine

    1999-09-01

    The paper discusses the main clinical value of bone scan in metabolic bone disease: its detection of focal conditions or focal complications of such generalized disease, its most common use of being the detection of fractures in osteoporosis, pseudo fractures in osteomalacia and the evaluation of Paget's disease.

  8. Primary investigation of dose-effect relationship of 153Sm-EDTMP in treating multiple bone metastases%153Sm-EDTMP治疗多发骨转移瘤的剂量效应关系初步观察

    Institute of Scientific and Technical Information of China (English)

    Wei Fan; Lixin Chen; Xiaowei Liu; Qiang Tang; Shengfang Zhi; Zongyuan Zeng

    2007-01-01

    Objective: To calculate the focus absorption dose of 153Sm-EDTMP with the Monte Carlo (MC) EGS4 method for treatment of bone metastases from nasopharyngeal carcinoma or breast cancer, and investigate the relationship between the focus absorption dose and painkilling effect of 153Sm-EDTMP. Methods: Four patients with multiple bone metastases from nasopharyngeal or breast carcinoma and suffered from grade Ⅳ bone pain were treated with radionuclide internal irradiation of 153Sm-EDTMP. The absorption dose and dose distribution of bone metastases and other targeted organs were calculated with MC EGS4 program based on the time-order SPECT/CT scanning and the measurement of the radioactivity in the urine accumulation. The release of bone pain and the improvement of life quality were observed. Results: Bone pain of the patients was significantly alleviated to grade Ⅱ for 3-4 weeks after internal 153Sm-EDTMP irradiation. The 3-dimensional absorption dose distribution image of bone metastases and targeted organs showed that the dose distribution in bone metastases was not asymmetrical. After injection of 0.65 × 37 MBq/kg 153Sm-EDTMP, the highest absorption dose in bone lesions was about 4.9-5.9 Gy, and the dose in the lesion margin was about 2.0 Gy. Using the highest dose as reference dose point, the relative absorption dose values of bone marrow, vertebra and sex organ near lesions were 0.48-1.1 Gy, 0.51-0.85 Gy, and 0.01-0.14 Gy, respectively. Conclusion: The absorption dose of bone metastases is significantly lower than treatment dose of 30 Gy after single irradiation of 153Sm-EDTMP. The painkilling effect is limited and in accordance with clinical observation.

  9. Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, P. A. [Centro de Investigação do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto, Portugal and Departamento de Física e Astronomia, Faculdade de Ciências da Universidade do Porto (Portugal); Santos, J. A. M., E-mail: joao.santos@ipoporto.min-saude.pt [Centro de Investigação do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto (Portugal); Serviço de Física Médica do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto (Portugal); Serviço de Medicina Nuclear do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto (Portugal); Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto (Portugal)

    2014-07-15

    Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as{sup 99m}Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of{sup 99m}Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using {sup 99m}Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for{sup 99m}Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

  10. Anti-CD45 radioimmunotherapy using 211At with bone marrow transplantation prolongs survival in a disseminated murine leukemia model

    Energy Technology Data Exchange (ETDEWEB)

    Orozco, Johnnie J.; Back, Tom; Kenoyer, Aimee L.; Balkin, Ethan R.; Hamlin, Donald K.; Wilbur, D. Scott; Fisher, Darrell R.; Frayo, Shani; Hylarides, Mark; Green, Damian J.; Gopal, Ajay K.; Press, Oliver W.; Pagel, John M.

    2013-05-15

    Anti-CD45 Radioimmunotherapy using an Alpha-Emitting Radionuclide 211At Combined with Bone Marrow Transplantation Prolongs Survival in a Disseminated Murine Leukemia Model ABSTRACT Despite aggressive chemotherapy combined with hematopoietic cell transplant (HCT), many patients with acute myeloid leukemia (AML) relapse. Radioimmunotherapy (RIT) using antibodies (Ab) labeled primarily with beta-emitting radionuclides has been explored to reduce relapse.

  11. Peptide receptor radionuclide therapy of neuroendocrine tumours.

    Science.gov (United States)

    Brabander, Tessa; Teunissen, Jaap J M; Van Eijck, Casper H J; Franssen, Gaston J H; Feelders, Richard A; de Herder, Wouter W; Kwekkeboom, Dik J

    2016-01-01

    In the past decades, the number of neuroendocrine tumours that are detected is increasing. A relative new and promising therapy for patients with metastasised or inoperable disease is peptide receptor radionuclide therapy (PRRT). This therapy involves an infusion of somatostatin analogues linked to radionuclides like Yttrium-90 or Lutetium-177. Objective response rates are reported in 15-35%. Response rates may vary between type of tumour and radionuclide. Besides the objective response rate, overall survival and progression free survival increase significantly. Also, the quality of life improves as well. Serious side-affects are rare. PRRT is usually well tolerated, also in patients with extensive metastasised disease. Recent studies combined PRRT with other types of therapies. Unfortunately no randomised trials comparing these strategies are available. In the future, more research is needed to evaluate the best therapy combinations or sequence of therapies.

  12. 2014 LANL Radionuclide Air Emissions Report

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-21

    This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2014, and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s RadNESHAP compliance program, which is part of the Environmental Protection Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Region 6.

  13. Thyroid Scan and Uptake

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ... the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is a ...

  14. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ... the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is a ...

  15. Thyroid Scan and Uptake

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses small ... Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is a type ...

  16. Radionuclide Therapies in Molecular Imaging and Precision Medicine.

    Science.gov (United States)

    Kendi, A Tuba; Moncayo, Valeria M; Nye, Jonathon A; Galt, James R; Halkar, Raghuveer; Schuster, David M

    2017-01-01

    This article reviews recent advances and applications of radionuclide therapy. Individualized precision medicine, new treatments, and the evolving role of radionuclide therapy are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. [Body composition analysis in obesity: radionuclide and non radionuclide methods].

    Science.gov (United States)

    Tzotzas, Themistoklis; Krassas, Gerasimos E; Doumas, Argirios

    2008-01-01

    Body composition (BC) assessment provides important information regarding the absolute or relative amount of bone, lean and fat tissue. Different somatometric techniques have been applied in numerous epidemiological and experimental studies, as well as in every day clinical practice. Traditional techniques for BC analysis include skin fold thickness measurements, radioisotope dilution methods, hydrodensitometry and underwater weighing, while newer techniques include bioelectrical impedance analysis (BIA), air displacement plethysmography (ADP), dual energy X-rays absorptiometry (DEXA), computer tomography and magnetic resonance imaging. In addition, positron emission tomography helped to the functional investigation of adipose tissue, in particular of brown tissue. All these techniques have contributed a lot to the understanding of physiological conditions such as exercise training, menopause and ageing, adolescence health parameters, as well as pathological conditions such as disorders of nutrition, cancer, obesity and diabetes mellitus. In obesity, BC contributed to diagnosis and the pathological impact of visceral adipose tissue. In addition, conditions such as pseudo- or hypermuscular obesity and sarcopenia, which are often observed in various endocrine diseases, were investigated in detail by using such methods. During weight loss, some of these methods were quite accurate in measuring changes in fat and lean mass. Apart from anthropometric measurements, a BC measurement if possible should be included in obesity assessment. Measurements of skin fold thickness combined with BIA are quite sufficient for routine clinical practice. However, in specialized clinics and in research, more sophisticated methods like ADP or DEXA are used.

  18. Migration of radionuclides in geologic media: Fundamental research needs

    Energy Technology Data Exchange (ETDEWEB)

    Reed, D.T. (Argonne National Lab., IL (USA)); Zachara, J.M.; Wildung, R.E. (Pacific Northwest Lab., Richland, WA (USA)); Wobber, F.J. (USDOE, Washington, DC (USA))

    1990-01-01

    An assessment of the fundamental research needs in understanding and predicting the migration of radionuclides in the subsurface is provided. Emphasis is on the following three technical areas: (1) aqueous speciation of radionuclides, (2) the interaction of radionuclides with substrates, and (3) intermediate-scale interaction studies. This research relates to important issues associated with environmental restoration and remediation of DOE sites contaminated with mixed radionuclide-organic wastes. 64 refs., 1 fig., 1 tab.

  19. Radiopharmaceuticals and other compounds labelled with short-lived radionuclides

    CERN Document Server

    Welch, Michael J

    2013-01-01

    Radiopharmaceuticals and Other Compounds Labelled with Short-Lived Radionuclides covers through both review and contributed articles the potential applications and developments in labeling with short-lived radionuclides whose use is restricted to institutions with accelerators. The book discusses the current and potential use of generator-produced radionuclides as well as other short-lived radionuclides, and the problems of quality control of such labeled compounds. The book is useful to nuclear medicine physicians.

  20. Bone Cancer

    Science.gov (United States)

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  1. Bone Diseases

    Science.gov (United States)

    Your bones help you move, give you shape and support your body. They are living tissues that rebuild constantly ... childhood and your teens, your body adds new bone faster than it removes old bone. After about ...

  2. Bone Markers

    Science.gov (United States)

    ... markers may be seen in conditions such as: Osteoporosis Paget disease Cancer that has spread to the bone (metastatic bone disease) Hyperparathyroidism Hyperthyroidism Osteomalacia in adults and rickets in children—lack of bone mineralization, ...

  3. Bone imaging in sports medicine.

    Directory of Open Access Journals (Sweden)

    Shikare S

    1997-07-01

    Full Text Available Increased participation in sports by the general public leads to increase in sports induced injuries including stress fractures, shin splints, arthritis and host of musculotendenous maladies. We have studied twenty patients referred from sports clinic for bone scanning to evaluate clinically difficult problems. It showed stress fracture in twelve patients, bilateral shin splint in five patients and normal bone scan in three patients. Present study highlights the utility of bone imaging for the diagnosis of various sports injuries in sports medicine.

  4. A rare case of polyostotic fibrous dysplasia assessed by bone scintigraphy with Tc-99m methylene diphosphonate (MDP)

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, C.; Ardemagni, A.; Bestetti, A.; Tagliabue, L.; Del Sole, A.; Conte, A.; Tarolo, G.L. [Milano Univ. (Italy). Servizio di Medicina Nucleare

    1999-07-01

    A 66-year-old man affected by polyostotic form of fibrous dysplasia in consequence of worsening of lower extremity bone pain aggravated by walking and concomitant increase of serum alkaline phosphatase and osteocalcin, was subjected first to a radionuclide study. Bone scan demonstrated a pathological uptake of the radiotracer in the craniofacial bones, right scapula, left and right posterior ribs, right hemipelvis and lower extremities confirming the diagnosis but establishing especially the extent of bone involvement, greater than expected on the basis of symptoms and X-ray findings, underlying the importance of nuclear medicine imaging in the assessment and follow-up of this rare disease. (orig.) [German] Bei einem 66jaehrigen Mann, der an der polyostotischen Form der fibroesen Dysplasie leidet, wurde aufgrund einer Verschlimmerung der Knochenschmerzen im Bereich der unteren Extremitaeten, die sich beim Gehen verschlechterten, und einer gleichzeitigen Erhoehung der Serumwerte fuer alkalische Phosphatase und Osteocalzin erstmals eine Radionuklid-Untersuchung durchgefuehrt. Das Knochenszintigramm zeigte eine pathologische Aufnahme des Radiotracers in den kraniofazialen Knochen, im rechten Schulterblatt, den linken und rechten posterioren Rippen, im Bereich von rechtem Hemipelvis und unteren Extremitaeten; damit wird die Diagnose bestaetigt, vor allem jedoch das Ausmass der Knochenbeteiligung nachgewiesen, das ueber das ausgehend von den Symptomen und Roentgenbefunden erwartete Ausmass hinausgeht; die Bedeutung des nuklearmedizinischen bildgebenden Verfahrens zur Beurteilung und Verlaufskontrolle dieser seltenen Erkrankung wird dadurch unterstrichen. (orig.)

  5. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5650 Manual radionuclide applicator system. (a) Identification. A manual radionuclide applicator system is a manually operated...

  6. Strategy for Bone Metastases Treatment in Patients with Impending Cord Compression or Vertebral Fractures: A Pilot Study

    OpenAIRE

    Rasulova, N.; Lyubshin, V.; Djalalov, F.; Kim, K. H.; Nazirova, L.; Ormanov, N.; Arybzhanov, D.

    2011-01-01

    Impending spinal cord compression and vertebral fractures are considered contraindications for radionuclide bone pain palliation therapy. However, most of the patients with widespread bone metastases already have weakened vertebral segments that may be broken. Therefore, local field external-beam radiotherapy or percutaneous vertebroplasty (VP) should be considered to improve the patient's quality of life and to institute subsequent appropriate treatment, including radionuclide therapy for bo...

  7. Plant uptake of radionuclides and rhizosphere factors

    Energy Technology Data Exchange (ETDEWEB)

    Arie, Tsutomu; Gouthu, S.; Ambe, Shizuko; Yamaguchi, Isamu [Institute of Physical and Chemical Research, Wako, Saitama (Japan); Hirata, Hiroaki

    1999-03-01

    Influence of soil factors such as nuclide availability, pH, organic carbon, cation exchange capacity (CEC), exchangeable cations (Ca{sup 2+}, Mg{sup 2+}, and K{sup +}), phosphate absorption coefficient (PAC), physical composition of soil (coarse sand, fine sand, silt, and clay), soil texture, and rhizosphere microbes on uptake of radionuclides by plants are studied. (author)

  8. Radionuclide tumor therapy with ultrasound contrast microbubbles

    NARCIS (Netherlands)

    Wamel, van Annemieke; Bouakaz, Ayache; Bernard, Bert; Cate, ten Folkert; Jong, de Nico

    2004-01-01

    Radionuclides have shown to be effective in tumour therapy. However, the side effects determine the maximum deliverable dose. Recently, it has been demonstrated that cells can be permeabilised through sonoporation using ultrasound and contrast microbubbles. The use of sonoporation in treatment of tu

  9. Chapter 7: Primary standardization in radionuclide metrology

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, Jose Ubiratan

    2014-07-01

    The chapter 7 presents: Primary methods for radionuclide standardization; 4πβ-γ Coincidence counting method; Anticoincidence; Counting π Method; Defined Solid Angle Counting Method; Liquid scintillator counting method (CIEMAT/NIST); Sum-peak Method and LNMRI Absolute Standardization.

  10. Radionuclide Geomicrobiology of the Deep Biosphere

    DEFF Research Database (Denmark)

    Anderson, Craig; Johnsson, Anna; Moll, Henry

    2011-01-01

    species (i.e., Shewanella putrefaciens and Desulfovibrio aespoeensis) with Cm, Pm, and Pu were investigated in vitro and the results were found to agree with literature data. Siderophores are capable of binding actinides strongly and need to be considered in terms of radionuclide mobility...

  11. RADIONUCLIDE TRANSPORT MODELS UNDER AMBIENT CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    S. Magnuson

    2004-11-01

    The purpose of this model report is to document the unsaturated zone (UZ) radionuclide transport model, which evaluates, by means of three-dimensional numerical models, the transport of radioactive solutes and colloids in the UZ, under ambient conditions, from the repository horizon to the water table at Yucca Mountain, Nevada.

  12. Radionuclides in radiation-induced bystander effect; may it share in radionuclide therapy?

    Science.gov (United States)

    Widel, M

    2017-01-01

    For many years in radiobiology and radiotherapy predominated the conviction that cellular DNA is the main target for ionizing radiation, however, the view has changed in the past 20 years. Nowadays, it is assumed that not only directed (targeted) radiation effect, but also an indirect (non-targeted) effect may contribute to the result of radiation treatment. Non-targeted effect is relatively well recognized after external beam irradiation in vitro and in vivo, and comprises such phenomena like radiation-induced bystander effect (RIBE), genomic instability, adaptive response and abscopal (out of field) effect. These stress-induced and molecular signaling mediated phenomena appear in non-targeted cells as variety responses resembling that observed in directly hit cells. Bystander effects can be both detrimental and beneficial in dependence on dose, dose-rate, cell type, genetic status and experimental condition. Less is known about radionuclide-induced non-targeted effects in radionuclide therapy, although, based on characteristics of the radionuclide radiation, on experiments in vitro utilizing classical and 3-D cell cultures, and preclinical study on animals it seems obvious that exposure to radionuclide is accompanied by various bystander effects, mostly damaging, less often protective. This review summarizes existing data on radionuclide induced bystander effects comprising radionuclides emitting beta- and alpha-particles and Auger electrons used in tumor radiotherapy and diagnostics. So far, separation of the direct effect of radionuclide decay from crossfire and bystander effects in clinical targeted radionuclide therapy is impossible because of the lack of methods to assess whether, and to what extent bystander effect is involved in human organism. Considerations on this topic are also included.

  13. Sediment and radionuclide transport in rivers: radionuclide transport modeling for Cattaraugus and Buttermilk Creeks, New York

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Y.; Yabusaki, S.B.; Kincaid, C.T.; Skaggs, R.L.; Walters, W.H.

    1982-12-01

    SERATRA, a transient, two-dimensional (laterally-averaged) computer model of sediment-contaminant transport in rivers, satisfactorily resolved the distribution of sediment and radionuclide concentrations in the Cattaraugus Creek stream system in New York. By modeling the physical processes of advection, diffusion, erosion, deposition, and bed armoring, SERATRA routed three sediment size fractions, including cohesive soils, to simulate three dynamic flow events. In conjunction with the sediment transport, SERATRA computed radionuclide levels in dissolved, suspended sediment, and bed sediment forms for four radionuclides (/sup 137/Cs, /sup 90/Sr, /sup 239/ /sup 240/Pu, and /sup 3/H). By accounting for time-dependent sediment-radionuclide interaction in the water column and bed, SERATA is a physically explicit model of radionuclide fate and migration. Sediment and radionuclide concentrations calculated by SERATA in the Cattaraugus Creek stream system are in reasonable agreement with measured values. SERATRA is in the field performance phase of an extensive testing program designed to establish the utility of the model as a site assessment tool. The model handles not only radionuclides but other contaminants such as pesticides, heavy metals and other toxic chemicals. Now that the model has been applied to four field sites, including the latest study of the Cattaraugus Creek stream system, it is recommended that a final model be validated through comparison of predicted results with field data from a carefully controlled tracer test at a field site. It is also recommended that a detailed laboratory flume be tested to study cohesive sediment transport, deposition, and erosion characteristics. The lack of current understanding of these characteristics is one of the weakest areas hindering the accurate assessment of the migration of radionuclides sorbed by fine sediments of silt and clay.

  14. Scientific Analysis Cover Sheet for Radionuclide Screening

    Energy Technology Data Exchange (ETDEWEB)

    G. Ragan

    2002-08-09

    The waste forms under consideration for disposal in the proposed repository at Yucca Mountain contain scores of radionuclides (Attachments V and VI). It would be impractical and highly inefficient to model all of these radionuclides in a total system performance assessment (TSPA). Thus, the purpose of this radionuclide screening analysis is to remove from further consideration (screen out) radionuclides that are unlikely to significantly contribute to radiation dose to the public from the proposed nuclear waste repository at Yucca Mountain. The remaining nuclides (those screened in) are recommended for consideration in TSPA modeling for license application. This analysis also covers radionuclides that are not screened in based on dose, but need to be included in TSPA modeling for other reasons. For example, U.S. Environmental Protection Agency (EPA) and U.S. Nuclear Regulatory Commission (NRC) regulations require consideration of the combined activity of Ra-226 and Ra-228 in groundwater (40 CFR 197.30, 10 CFR 63.331). Also, Cm-245, Pu-241, and U-235 decay indirectly to potentially important radionuclides, and are not identified by the screening analysis as important. The radionuclide screening analysis separately considers two different postclosure time periods: the 10,000-y regulatory period for the proposed repository at Yucca Mountain and the period after 10,000 y up to 1 million y after emplacement. The incremental effect of extending the screening for the regulatory period to 20,000 y is also addressed. Four release scenarios are considered: (1) the nominal scenario, which entails long-term degradation of disposal containers and waste forms, (2) a human-intrusion scenario, (3) an intrusive igneous event, and (4) an eruptive igneous event. Because the first three scenarios require groundwater transport, they are called groundwater scenarios below. The screening analysis considers the following waste forms: spent boiling water reactor (BWR) fuel, spent

  15. RADIONUCLIDES DISTRIBUTION NEAR FORMER URANIUM MINING

    Directory of Open Access Journals (Sweden)

    D. A. Zaredinov

    2016-01-01

    Full Text Available The paper shows, that radionuclides from the stony rocks of uranium mines can be leached by atmospheric precipitations. In acid conditions, a degree of leaching is greater.Goal. The aim of this investigation was to study the distribution of radionuclides in uranium minings and their impact on the environmental contamination.Materials and methods. The study was carried out in two stages. In the first stage, a blade of rock was mixed with distilled water in proportions of 0,3 kg of gravel and 1 liter of water. After thirty days of soaking, water was sent to the gamma-spectrometric analysis to Canberra’s spectrometer (USA with a high-purity germanium detector. In the second stage, we carried out the similar experiment with water, wich was acidified to pH = 3. Contamination levels of areas near the in-situ leaching mine were determined. Intervention levels were used to estimate risk and possible water consumption by the population. Estimations were carried out taking into account the combined presence of several radionuclides in the water.Results. The results of these studies have shown that the distribution of radionuclides from the source of the contamination is about 360 meters during the 30 y period. The stream, along which samples of soil were collected and studied, was formed by the miner waters that flow along small ruts towards a village, thereby increasing the likelihood of water use by the public.Conclusions. The uranium mines are the source of radioactive contamination. Radionuclides are distributed due to the erosion of rocks and leached out of the stony rock by precipitations. The extent of leaching is significantly increased in an acidic environment, which takes place near the in-situ leaching mines.

  16. 2006 LANL Radionuclide Air Emissions Report

    Energy Technology Data Exchange (ETDEWEB)

    David P. Fuehne

    2007-06-30

    This report describes the impacts from emissions of radionuclides at Los Alamos National Laboratory (LANL) for calendar year 2006. This report fulfills the requirements established by the Radionuclide National Emissions Standards for Hazardous Air Pollutants (Rad-NESHAP). This report is prepared by LANL's Rad-NESHAP compliance team, part of the Environmental Protection Division. The information in this report is required under the Clean Air Act and is being reported to the U.S. Environmental Protection Agency (EPA). The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL's EDE was 0.47 mrem for 2006. The annual limit established by the EPA is 10 mrem per year. During calendar year 2006, LANL continuously monitored radionuclide emissions at 28 release points, or stacks. The Laboratory estimates emissions from an additional 58 release points using radionuclide usage source terms. Also, LANL uses a network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates meteorological monitoring systems. From these measurement systems, a comprehensive evaluation is conducted to calculate the EDE for the Laboratory. The EDE is evaluated as any member of the public at any off-site location where there is a residence, school, business, or office. In 2006, this location was the Los Alamos Airport Terminal. The majority of this dose is due to ambient air sampling of plutonium emitted from 2006 clean-up activities at an environmental restoration site (73-002-99; ash pile). Doses reported to the EPA for the past 10 years are shown in Table E1.

  17. Helix Scan: A Scan Design for Diagnosis

    Institute of Scientific and Technical Information of China (English)

    WANG Fei; HU Yu; LI Xiaowei

    2007-01-01

    Scan design is a widely used design-for-testability technique to improve test quality and efficiency. For the scan-designed circuit, test and diagnosis of the scan chain and the circuit is an important process for silicon debug and yield learning. However, conventional scan designs and diagnosis methods abort the subsequent diagnosis process after diagnosing the scan chain if the scan chain is faulty. In this work, we propose a design-for-diagnosis scan strategy called helix scan and a diagnosis algorithm to address this issue. Unlike previous proposed methods, helix scan has the capability to carry on the diagnosis process without losing information when the scan chain is faulty. What is more, it simplifies scan chain diagnosis and achieves high diagnostic resolution as well as accuracy. Experimental results demonstrate the effectiveness of our design.

  18. BoneJ: Free and extensible bone image analysis in ImageJ.

    Science.gov (United States)

    Doube, Michael; Kłosowski, Michał M; Arganda-Carreras, Ignacio; Cordelières, Fabrice P; Dougherty, Robert P; Jackson, Jonathan S; Schmid, Benjamin; Hutchinson, John R; Shefelbine, Sandra J

    2010-12-01

    Bone geometry is commonly measured on computed tomographic (CT) and X-ray microtomographic (μCT) images. We obtained hundreds of CT, μCT and synchrotron μCT images of bones from diverse species that needed to be analysed remote from scanning hardware, but found that available software solutions were expensive, inflexible or methodologically opaque. We implemented standard bone measurements in a novel ImageJ plugin, BoneJ, with which we analysed trabecular bone, whole bones and osteocyte lacunae. BoneJ is open source and free for anyone to download, use, modify and distribute.

  19. Food habits and radionuclide tissue concentrations of Nevada desert bighorn sheep, 1972--1973

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.W.; Smith, D.D.; Bernhardt, D.E.; Giles, K.R.; Helvie, J.B.

    1976-06-01

    The botanical composition of the diet and radionuclide content of selected tissues of desert bighorn sheep (Ovis canadensis nelsoni) collected during the 1972 and 1973 hunting seasons were determined by analyzing rumen contents, and lung, liver, kidney, and bone tissues. Botanical examination of the rumen contents showed that grass exceeded 50 percent of the diet of 10 to 14 animals collected in 1972 and 12 of 18 animals collected in 1973. Desert needlegrass (Stipa speciosa), Indian rice grass (Oryzopsis hymenoides), and squirrel tail (Sitanion hystrix) were the major grasses utilized. The dominant shrub species consumed included the joint firs (Ephedra viridis) and (Ephedra nevadensis), Mohave yucca (Yucca schidigera), and cliff rose (Cowania mexicana). With the exception of potassium-40, gamma-emitting radionuclides were not detected in desert bighorn sheep tissue. The tritium levels reported were within environmental levels. Strontium-90 levels averaged 4.9 and 4.1 pCi/gram of bone ash for 1972 and 1973, respectively, continuing the downward trend observed in recent years. Uranium levels were similar to those reported from cattle grazing the same general geographic areas. The daily consumption for one year of 500 grams of liver containing the highest levels of plutonium and uranium would result in a dose to the human bone, the tissue expected to receive the highest dose, of approximately 1 mrem/year. This is less than 1% of the radiation protection guides for the general population.

  20. Methods of increasing the performance of radionuclide generators used in nuclear medicine: daughter nuclide build-up optimisation, elution-purification-concentration integration, and effective control of radionuclidic purity.

    Science.gov (United States)

    Le, Van So; Do, Zoe Phuc-Hien; Le, Minh Khoi; Le, Vicki; Le, Natalie Nha-Truc

    2014-06-10

    Methods of increasing the performance of radionuclide generators used in nuclear medicine radiotherapy and SPECT/PET imaging were developed and detailed for 99Mo/99mTc and 68Ge/68Ga radionuclide generators as the cases. Optimisation methods of the daughter nuclide build-up versus stand-by time and/or specific activity using mean progress functions were developed for increasing the performance of radionuclide generators. As a result of this optimisation, the separation of the daughter nuclide from its parent one should be performed at a defined optimal time to avoid the deterioration in specific activity of the daughter nuclide and wasting stand-by time of the generator, while the daughter nuclide yield is maintained to a reasonably high extent. A new characteristic parameter of the formation-decay kinetics of parent/daughter nuclide system was found and effectively used in the practice of the generator production and utilisation. A method of "early elution schedule" was also developed for increasing the daughter nuclide production yield and specific radioactivity, thus saving the cost of the generator and improving the quality of the daughter radionuclide solution. These newly developed optimisation methods in combination with an integrated elution-purification-concentration system of radionuclide generators recently developed is the most suitable way to operate the generator effectively on the basis of economic use and improvement of purposely suitable quality and specific activity of the produced daughter radionuclides. All these features benefit the economic use of the generator, the improved quality of labelling/scan, and the lowered cost of nuclear medicine procedure. Besides, a new method of quality control protocol set-up for post-delivery test of radionuclidic purity has been developed based on the relationship between gamma ray spectrometric detection limit, required limit of impure radionuclide activity and its measurement certainty with respect to

  1. Radionuclide evaluation in malignant external otitis; Avaliacao com radionuclideos da otite externa maligna

    Energy Technology Data Exchange (ETDEWEB)

    Wolosker, Sara; Penha Costa Marques, Marise da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Fonseca, Lea Miriam Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina]|[Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    1996-03-01

    Malignant external otitis (MEO) is a severe infection of the external auditory canal that can result in osteomyelitis of the skull base. Twenty-eight patients with MEO (19 diabetics, 8 with AIDS and 1 with acute mielogenous leukemia) were evaluated using {sup 99m} Tc-MDP bone scintigraphy. {sup 67} Ga citrate and computed tomography (CT) at the time of diagnosis for establishing the MEO extent. {sup 67} Ga scans were obtained periodically in order to assess the evolution of the treatment. {sup 99m} Tc scans had shown high sensitivity and specificity in assessing the bone disease. Serial {sup 67} Ga scans had shown to be valuable indicators of infection remission. CT scans provided poor diagnosis of early bone involvement. (author). 26 refs., 4 figs.

  2. Vesicoureteric reflux: Evaluation by bladder volume graded direct radionuclide cystogram

    Directory of Open Access Journals (Sweden)

    Agrawal Vikesh

    2009-01-01

    Full Text Available Aim : Evaluation of vesicoureteric reflux (VUR in children by bladder volume graded direct radionuclide cystogram (BVG DRC. This technique allows detection of VUR at different bladder volume grades. Materials and Methods : In this prospective study, 33 patients (66 renal units with suspected vesicoureteric reflux were subjected to a voiding cystourethrogram (VCUG and BVG DRC. The patients were assessed further with radioisotope renal scans for renal cortical scars. Results : Twenty-two patients and 36 renal units were found to have VUR in either of the reflux studies. A VCUG was able to detect 20 units (55.50% and a BVG DRC was able to detect 35 units (97.2%. A VCUG had a test accuracy of 77.8% and a BVG DRC had a test accuracy of 98.6%. There was a positive correlation between bladder volume grades and scarring on a DMSA scan. Conclusions : Like a conventional DRC, BVG DRC is a sensitive and an accurate test. It gives additional information on the reflux phenomenon with respect to bladder filling. The bladder volume graded technique is better than conventional DRC for grading of VUR.

  3. National Low-Level Waste Management Program Radionuclide Report Series

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, M.J.; Garcia, R.S.

    1992-02-01

    This volume serves as an introduction to the National Low-Level Radioactive Waste Management Program Radionuclide Report Series. This report includes discussions of radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha-emitting transuranics with half-lives greater than five years). Each report includes information regarding radiological and chemical characteristics of specific radionuclides. Information is also included discussing waste streams and waste forms that may contain each radionuclide, and radionuclide behavior in the environment and in the human body. Not all radionuclides commonly found at low-level radioactive waste sites are included in this report. The discussion in this volume explains the rationale of the radionuclide selection process.

  4. Uptake by plants of radionuclides from FUSRAP waste materials

    Energy Technology Data Exchange (ETDEWEB)

    Knight, M.J.

    1983-04-01

    Radionuclides from FUSRAP wastes potentially may be taken up by plants during remedial action activities and permanent near-surface burial of contaminated materials. In order to better understand the propensity of radionuclides to accumulate in plant tissue, soil and plant factors influencing the uptake and accumulation of radionuclides by plants are reviewed. In addition, data describing the uptake of the principal radionuclides present in FUSRAP wastes (uranium-238, thorium-230, radium-226, lead-210, and polonium-210) are summarized. All five radionuclides can accumulate in plant root tissue to some extent, and there is potential for the translocation and accumulation of these radionuclides in plant shoot tissue. Of these five radionuclides, radium-226 appears to have the greatest potential for translocation and accumulation in plant shoot tissue. 28 references, 1 figure, 3 tables.

  5. Radium-223 treatment of bone metastases from castration-resistant prostate cancer

    DEFF Research Database (Denmark)

    Mortensen, Jann; Højgaard, Liselotte

    2014-01-01

    The alpha emitter Radium-223 ((22)3Ra-Cl2) is a bone-seeking radionuclide studied as a new treatment for patients with bone metastases from hormone refractory prostate cancer. More than 1,000 patients have been included in clinical phase I-III tests showing significant reduction in alkaline...

  6. Abscopal induction of leukaemia and osteosarcoma following administration of alpha-emitting radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Lord, B.I. (Paterson Institute for Cancer Research, Christie Hospital Manchester, Manchester (United Kingdom))

    2008-12-15

    Alpha-particle-emitting, bone-seeking radionuclides can induce leukaemia and/ or osteosarcoma in mice. Furthermore, plutonium-239, given to male mice before mating with normal females, while not directly leading to leukaemia in the progeny does lead to enhanced susceptibility to leukaemogenic agents. In the first case, the amounts of radionuclide are very small in experimental terms; and zero in the case of transgenerational activity. In both cases, the development of the disorders is remote in time and location relative to that of the contaminating radionuclide, making interpretation of the mechanisms and estimation of radiation risk problematic. It is necessary, then, to address questions involving the basis of haemopoiesis itself. Cellular kinetics of the development of blood from the pluripotent stem cells to the mature functional cells are outlined, describing compensatory proliferation mechanisms and extensive movement of cells throughout the marrow space. The locations of potential oncogenic target cells are identified and the nature of the stromal microenvironment that regulates haemopoiesis is defined. Plutonium-239, given to male mice, targets spermatogenesis at the stem cell level leaving unidentified damage that is inherited by his offspring. This leaves the offspring susceptible to a leukaemogenic agent encountered later in life. The characteristics of this, corroborated by consideration of the cellular kinetics, are of an inherited genomic instability. Cells of the microenvronment, inheriting the same genetic damage, probably act in the role of an enhancing 'bystander'. In adult mice, the mechanisms are different. Bone turnover results in radioactivity being gradually transported through the marrow by long-lived macrophages. A model based on temporal microdistributions of activity, defining specific target cell regions, is able to illustrate that considering bone marrow as a uniform mass of cells is inadequate to describe the observed

  7. Radionuclide-Based Cancer Imaging Targeting the Carcinoembryonic Antigen

    Directory of Open Access Journals (Sweden)

    Hao Hong

    2008-01-01

    Full Text Available Carcinoembryonic antigen (CEA, highly expressed in many cancer types, is an important target for cancer diagnosis and therapy. Radionuclide-based imaging techniques (gamma camera, single photon emission computed tomography [SPECT] and positron emission tomography [PET] have been extensively explored for CEA-targeted cancer imaging both preclinically and clinically. Briefly, these studies can be divided into three major categories: antibody-based, antibody fragment-based and pretargeted imaging. Radiolabeled anti-CEA antibodies, reported the earliest among the three categories, typically gave suboptimal tumor contrast due to the prolonged circulation life time of intact antibodies. Subsequently, a number of engineered anti-CEA antibody fragments (e.g. Fab’, scFv, minibody, diabody and scFv-Fc have been labeled with a variety of radioisotopes for CEA imaging, many of which have entered clinical investigation. CEA-Scan (a 99mTc-labeled anti-CEA Fab’ fragment has already been approved by the United States Food and Drug Administration for cancer imaging. Meanwhile, pretargeting strategies have also been developed for CEA imaging which can give much better tumor contrast than the other two methods, if the system is designed properly. In this review article, we will summarize the current state-of-the-art of radionuclide-based cancer imaging targeting CEA. Generally, isotopes with short half-lives (e.g. 18F and 99mTc are more suitable for labeling small engineered antibody fragments while the isotopes with longer half-lives (e.g. 123I and 111In are needed for antibody labeling to match its relatively long circulation half-life. With further improvement in tumor targeting efficacy and radiolabeling strategies, novel CEA-targeted agents may play an important role in cancer patient management, paving the way to “personalized medicine”.

  8. Radionuclide-Based Cancer Imaging Targeting the Carcinoembryonic Antigen

    Science.gov (United States)

    Hong, Hao; Sun, Jiangtao; Cai, Weibo

    2008-01-01

    Carcinoembryonic antigen (CEA), highly expressed in many cancer types, is an important target for cancer diagnosis and therapy. Radionuclide-based imaging techniques (gamma camera, single photon emission computed tomography [SPECT] and positron emission tomography [PET]) have been extensively explored for CEA-targeted cancer imaging both preclinically and clinically. Briefly, these studies can be divided into three major categories: antibody-based, antibody fragment-based and pretargeted imaging. Radiolabeled anti-CEA antibodies, reported the earliest among the three categories, typically gave suboptimal tumor contrast due to the prolonged circulation life time of intact antibodies. Subsequently, a number of engineered anti-CEA antibody fragments (e.g. Fab’, scFv, minibody, diabody and scFv-Fc) have been labeled with a variety of radioisotopes for CEA imaging, many of which have entered clinical investigation. CEA-Scan (a 99mTc-labeled anti-CEA Fab’ fragment) has already been approved by the United States Food and Drug Administration for cancer imaging. Meanwhile, pretargeting strategies have also been developed for CEA imaging which can give much better tumor contrast than the other two methods, if the system is designed properly. In this review article, we will summarize the current state-of-the-art of radionuclide-based cancer imaging targeting CEA. Generally, isotopes with short half-lives (e.g. 18F and 99mTc) are more suitable for labeling small engineered antibody fragments while the isotopes with longer half-lives (e.g. 123I and 111In) are needed for antibody labeling to match its relatively long circulation half-life. With further improvement in tumor targeting efficacy and radiolabeling strategies, novel CEA-targeted agents may play an important role in cancer patient management, paving the way to “personalized medicine”. PMID:19578524

  9. A case report of disabling bone pain after long-term kidney transplantation.

    Science.gov (United States)

    Myint, T M M; Vucak-Dzumhur, M; Ebeling, P R; Elder, G J

    2014-02-01

    A 77-year-old man, who received a renal transplant 13 years before for IgA glomerulonephritis, was referred after he developed bilateral mid-tibial aching pain that did not improve with simple analgesia. He had recently been changed from low-dose cyclosporine to tacrolimus, but the pain did not improve when this was reversed. He had a history of focal prostatic adenocarcinoma, cryptococcal lung infection, osteoporosis treated with alendronate for 2 years and multiple squamous cell carcinomas, including one requiring left neck dissection and radiotherapy. Upon physical examination, he had gouty tophi and marked bilateral tibial tenderness but had no other clinical findings. Laboratory investigations included an elevated intact parathyroid hormone value of 7.9 pmol/L (1.6 to 6.9), bone specific alkaline phosphatase of 22 µg/L (3.7 to 20.9), urinary deoxypyridinoline/creatinine ratio of 7.2 nmol/mmol (2.5 to 5.4) and C-reactive protein. Chest X-ray and tibial X-rays were normal, but there was marrow oedema and a prominent periosteal reaction on magnetic resonance imaging. A radionuclide bone scan showed increased symmetrical, linear uptake in both tibiae and the left femur, and uptake was also noted in both clinically asymptomatic humeri. Tibial bone biopsy disclosed small deposits of poorly differentiated metastatic cancer and a follow-up chest CT revealed a lung lesion. It was concluded that the bone pain and periostitis was caused by primary lung cancer with metastatic disease to bone, and an associated hypertrophic osteoarthropathy.

  10. Lumbar spine CT scan

    Science.gov (United States)

    CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... your breath for short periods of time. The scan should take only 10 to 15 minutes.

  11. Bone infarction - A rare complication of pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Lundberg, T.M.; Jesspo, J.F.; Wong, J.C.H. [Royal Brisbane Hospital, Herston, QLD (Australia). Department of Nuclear Medicine

    1997-09-01

    Full text: In this study a combination of a {sup 99m}Tc MDP Bone scan and {sup 67}Ga scan was used to help in the diagnosis of bone infarction, in a patient with known pancreatitis. A 40-year-old male patient presented to hospital with a history of abdominal epigastric pain and generalised joint pains especially in his left knee and foot. He was recovering after a diagnosis four months earlier of hypertension and pancreatitis. On examination, he was febrile, and had scattered erythematous nodules on both legs. There were joint effusions involving his elbows, knees and ankles. (A series of tests, seemed to suggest either an inflammatory process or osteomyelitis.) At this stage, a two phase bone scan was performed which showed several areas of marked hyperaemia on the blood pools and intense abnormal uptake in the delayed images. Differential diagnosis was bone infarcts or multifocal osteomyelitis. A gallium scan was performed. The combined bone and gallium studies were more in keeping with bone infarcts. Conservative treatment was instituted and a repeat bone scan one year later showed marked improvement. Since pancreatitis is rarely complicated by bone infarction, the diagnosis is often delayed. In this case, nuclear medicine imaging played a very decisive role in excluding osteomyelitis and diagnosing the presence of widespread bone infarction-a rare sequela of pancreatitis.

  12. Radionuclide imaging in skeletal inflammatory and ischemic disease in children. [/sup 99m/Tc tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Majd, M.; Frankel, R.S.

    1976-04-01

    Sixty-five children were evaluated for presence of skeletal inflammatory and ischemic disease with bone scans and roentgenograms. Several characteristic scintigraphic patterns were observed. Bone scans were significantly more sensitive than roentgenograms in early diagnosis of osteomyelitis and its differentiation from cellulitis, septic arthritis, and bone infarction. The child with possible inflammatory bone disease now is benefited by this important refinement in diagnosis. Faced with the difficult dilemma of choosing appropriate therapy in these frustratingly similar problems, the physician can integrate the clinical findings with nuclear imaging to arrive at early appropriate diagnosis and management.

  13. Identifying large chondrites using cosmogenic radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welten, K.C. [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States); Caffee, M.W., E-mail: mcaffee@purdue.ed [PRIME Laboratory, Purdue University, West Lafayette, IN 47907 (United States); Hillegonds, D.J. [Center for Accelerator Mass Spectrometry, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Masarik, J. [Department of Nuclear Physics, Comenius University, Bratislava (Slovakia); Nishiizumi, K. [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States)

    2010-04-15

    We measured the concentrations of the cosmogenic radionuclides {sup 10}Be, {sup 26}Al, {sup 36}Cl and {sup 41}Ca in the metal and stone fractions of three large chondrite showers to determine their pre-atmospheric size. Large chondrites are characterized by substantial contributions of neutron-capture {sup 41}Ca in the stone fraction (up to approx2 dpm/gCa), low radionuclide concentrations in the metal fraction and high {sup 10}Be(stone)/{sup 10}Be(metal) ratios. Based on the measured concentrations in comparison with calculated cosmogenic nuclide depth profiles, using a semi-empirical and a purely physical model, we conclude that these objects had pre-atmospheric radii ranging from approx80 cm to >3 m. We conclude that the semi-empirical model is more reliable for spallogenic production rates in large objects, while the purely physical model is more reliable for neutron-capture products.

  14. Tracing Noble Gas Radionuclides in the Environment

    CERN Document Server

    Collon, P; Lu, Z T

    2004-01-01

    Trace analysis of radionuclides is an essential and versatile tool in modern science and technology. Due to their ideal geophysical and geochemical properties, long-lived noble gas radionuclides, in particular, 39Ar (t1/2 = 269 yr), 81Kr (t1/2 = 2.3x10^5 yr) and 85Kr (t1/2 = 10.8 yr), have long been recognized to have a wide range of important applications in Earth sciences. In recent years, significant progress has been made in the development of practical analytical methods, and has led to applications of these isotopes in the hydrosphere (tracing the flow of groundwater and ocean water). In this article, we introduce the applications of these isotopes and review three leading analytical methods: Low-Level Counting (LLC), Accelerator Mass Spectrometry (AMS) and Atom Trap Trace Analysis (ATTA).

  15. Radionuclide synovectomy – essentials for rheumatologists

    Directory of Open Access Journals (Sweden)

    Marek M. Chojnowski

    2016-07-01

    Full Text Available Radionuclide synovectomy is a minimally invasive method of treating persistent joint inflammation. It involves intra-articular injection of radioactive colloids which induce necrosis and fibrosis of hypertrophic synovial membrane. The most common indication for radiosynovectomy is rheumatoid arthritis, although patients with seronegative spondyloarthropathies, unclassified arthritis, haemophilic arthropathy and other less common arthropathies can also benefit from this method. Radiosynovectomy is safe, well tolerated and efficacious. About 70–80% of patients respond well to the therapy. However, the therapeutic effects are considerably worse in patients with co-existent osteoarthritis and advanced joint degeneration. Despite its advantages, radionuclide synovectomy is not performed as often as it could be, so greater knowledge and understanding of this method are needed. The authors present the most important facts about radiosynovectomy that may help rheumatologists in their daily clinical practice.

  16. Radionuclide transport in the Yenisei River

    CERN Document Server

    Vakulovsky, S M; Kabanov, A I

    2012-01-01

    Data characterizing the pollution of the Yenisei River (water and bottom sediment) by radionuclide resulting from the use of the river water for cooling industrial reactors in the Mining-Chemical Complex are presented. Studies have been made of the contamination of the river during the period when reactors with direct flow cooling were used and after these were shut down. Distinctive features of the migration of radionuclide in the Yenisei are noted, in particular, their distribution between the solid and liquid phases. The amounts of 137Cs, 65Zn, 60Co, 54Mn, and 152Eu in the channel are determined from the effluent discharge site to Dudinka port. The rate of continuous self removal of 137Cs is estimated to be 0.19 1/year, corresponding to a half purification time of 3.6 years for a 600 km long segment of the river bed.

  17. Radionuclide synovectomy – essentials for rheumatologists

    Science.gov (United States)

    Felis-Giemza, Anna; Kobylecka, Małgorzata

    2016-01-01

    Radionuclide synovectomy is a minimally invasive method of treating persistent joint inflammation. It involves intra-articular injection of radioactive colloids which induce necrosis and fibrosis of hypertrophic synovial membrane. The most common indication for radiosynovectomy is rheumatoid arthritis, although patients with seronegative spondyloarthropathies, unclassified arthritis, haemophilic arthropathy and other less common arthropathies can also benefit from this method. Radiosynovectomy is safe, well tolerated and efficacious. About 70–80% of patients respond well to the therapy. However, the therapeutic effects are considerably worse in patients with co-existent osteoarthritis and advanced joint degeneration. Despite its advantages, radionuclide synovectomy is not performed as often as it could be, so greater knowledge and understanding of this method are needed. The authors present the most important facts about radiosynovectomy that may help rheumatologists in their daily clinical practice. PMID:27504020

  18. Decline of radionuclides in Columbia River biota

    Energy Technology Data Exchange (ETDEWEB)

    Cushing, C.E.; Watson, D.G.; Scott, A.J.; Gurtisen, J.M.

    1980-03-01

    In January 1971, the last of nine plutonium production reactors using direct discharge of once-through cooling waters into the Columbia River was closed. Sampling was initiated at three stations on the Columbia River to document the decline of the radionuclide body burdens in the biota of the Columbia River ecosystem. The data show that in a river-reservoir complex, the measurable body burden of fission-produced radionuclides decreased to essentially undetectable levels within 18 to 24 mo after cessation of discharge of once-through cooling water into the river. On the basis of data from the free-flowing station, we believe that this decrease would be even more rapid in an unimpounded river.

  19. Radionuclides accumulation in milk and its products

    Energy Technology Data Exchange (ETDEWEB)

    Marmuleva, N.I.; Barinov, E.Y.; Petukhov, V.L. [Novosibirsk State Agrarian University (Russian Federation)

    2003-05-01

    The problem of radioactive pollution is extremely urgent in Russia in connection with presence of territories polluted by radionuclides on places of nuclear tests, in zones around the enterprises on production, processing and storage of radioactive materials, and also in areas of emergency pollution (Barakhtin, 2001). The aim of our investigation was a determination of the levels of the main radioactive elements - {sup 137}Cs and {sup 90}Sr in diary products. 363 samples of milk, dry milk, butter, cheese and yogurt from Novosibirsk region were examined. {sup 137}Cs level was 3.7 to 9.2 times higher than {sup 90}Sr one in milk, cheese and yogurt. At the same time the level of these radio-nuclides in butter was identical (8.03 Bk/kg). (authors)

  20. Improving cancer treatment with cyclotron produced radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author's continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  1. Cadastral valuation of lands polluted with radionuclides

    Science.gov (United States)

    Makarov, O. A.; Tsvetnov, E. V.; Shcheglov, A. I.; Romashkina, A. D.; Ermiyaev, Ya. R.

    2016-11-01

    The major method to correct the cadastral value of land for contamination with radionuclides is to reduce it by the sum of expenses necessary for land remediation and for special measures ensuring the obtaining of agricultural and forestry products satisfying safety norms. Lands contaminated with radionuclides and used in agriculture and forestry are often removed from the system of land taxation. In this case, their cadastral value becomes an excessive element of the state cadaster of real estate. An approach toward cadastral valuation of such lands suggested by the authors assumes the creation of a system of compensation payments as the main source of financing of land rehabilitation and soil conservation measures. An original system of calculation of such payments has been tested for radioactively contaminated lands in Plavsk district of Tula oblast. It is argued that compensation payments for radioactively contaminated agrocenoses should be higher than those for natural cenoses.

  2. Radionuclide methods of tumor diagnosis in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Dubinskaya, L.R. (Nauchno-Issledovatel' skij Inst. Glaznykh boleznej (USSR))

    1982-08-01

    The radionuclide methods used in opthalmology for diagnosis of eyes and orbit tumors are described: radiophosphorus indication, method of gamma-topography, method of external radiometry, method of blood circulation study in organ of vision. Diagnostic value was determined of such radiopharmaceuticals as /sup 32/P-phosphate, /sup 67/Ga-citrate, /sup 131/I-Ralbumin, /sup 197/Hg-neohydrine, /sup 125/I-fluorescein, /sup 75/Se-methionine, sup(99m)Tc-pertechnete and others. The conclusion was drawn that the considered radionuclides and radiopharmaceuticals were not perfect indicators for diagnosis of different tumors of organ of vision. Simultaneous using of several radiopharmaceuticals with the aim of increasing information content of described methods is recommended.

  3. Radionuclide evaluation of renal artery dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Born, M.L.; Gerlock, A.J. Jr.; Goncharenko, V.; Hollifield, J.W.; MacDonell, R.C. Jr.

    1981-01-01

    Radionuclide studies were used in three patients to evaluate renal perfusion and function within 24 hours following transluminal dilatation. In one patient, technetium-99 m pertechnetate showed good renal perfusion one and 12 hours after a post-dilatation arteriogram had shown a renal artery intimal defect. Improved clearance of iodine-131 ortho-iodohippurate from the blood demonstrated an increase in renal function 18 hours following dilatation of a stenosis at a renal allograft anastomosis in the second patient, while technetium-99 m-labeled DTPA showed an improved total glomerular filtration rate 24 hours after dilatation of a saphenous vein bypass graft in the third patient. It was concluded that renal radionuclide studies are of benefit in evaluating patients in the immediate post-dilatation period.

  4. Bone marrow aspiration

    Science.gov (United States)

    Iliac crest tap; Sternal tap; Leukemia - bone marrow aspiration; Aplastic anemia - bone marrow aspiration; Myelodysplastic syndrome - bone marrow aspiration; Thrombocytopenia - bone marrow aspiration; Myelofibrosis - bone marrow aspiration

  5. Radionuclide release calculations for SAR-08

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, Gavin; Miller, Alex; Smith, Graham; Jackson, Duncan (Enviros Consulting Ltd, Wolverhampton (United Kingdom))

    2008-04-15

    Following a review by the Swedish regulatory authorities of the post-closure safety assessment of the SFR 1 disposal facility for low and intermediate waste (L/ILW), SAFE, the SKB has prepared an updated assessment called SAR-08. This report describes the radionuclide release calculations that have been undertaken as part of SAR-08. The information, assumptions and data used in the calculations are reported and the results are presented. The calculations address issues raised in the regulatory review, but also take account of new information including revised inventory data. The scenarios considered include the main case of expected behaviour of the system, with variants; low probability releases, and so-called residual scenarios. Apart from these scenario uncertainties, data uncertainties have been examined using a probabilistic approach. Calculations have been made using the AMBER software. This allows all the component features of the assessment model to be included in one place. AMBER has been previously used to reproduce results the corresponding calculations in the SAFE assessment. It is also used in demonstration of the IAEA's near surface disposal assessment methodology ISAM and has been subject to very substantial verification tests and has been used in verifying other assessment codes. Results are presented as a function of time for the release of radionuclides from the near field, and then from the far field into the biosphere. Radiological impacts of the releases are reported elsewhere. Consideration is given to each radionuclide and to each component part of the repository. The releases from the entire repository are also presented. The peak releases rates are, for most scenarios, due to organic C-14. Other radionuclides which contribute to peak release rates include inorganic C-14, Ni-59 and Ni-63. (author)

  6. Radionuclide Air Emission Report for 2008

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Linnea

    2009-05-21

    Berkeley Lab operates facilities where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) radioactive air emission regulations in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H (EPA 1989). Radionuclides may be emitted from stacks or vents on buildings where radionuclide production or use is authorized or they may be emitted as diffuse sources. In 2008, all Berkeley Lab sources were minor sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]). These minor sources include more than 100 stack sources and one source of diffuse emissions. There were no unplanned emissions from the Berkeley Lab site. Emissions from minor sources (stacks and diffuse emissions) either were measured by sampling or monitoring or were calculated based on quantities used, received for use, or produced during the year. Using measured and calculated emissions, and building-specific and common parameters, Laboratory personnel applied the EPA-approved computer code, CAP88-PC, to calculate the effective dose equivalent to the maximally exposed individual (MEI). The effective dose equivalent from all sources at Berkeley Lab in 2008 is 5.2 x 10{sup -3} mrem/yr (5.2 x 10{sup -5} mSv/yr) to the MEI, well below the 10 mrem/yr (0.1 mSv/yr) dose standard. The location of the MEI is at the University of California (UC) Lawrence Hall of Science, a public science museum about 1500 ft (460 m) east of Berkeley Lab's Building 56. The estimated collective effective dose equivalent to persons living within 50 mi (80 km) of Berkeley Lab is 1.1 x 10{sup -1} person-rem (1.1 x 10{sup -3} person-Sv) attributable to the Lab's airborne emissions in 2008.

  7. Loading technique for preparing radionuclide containing nanoparticles

    DEFF Research Database (Denmark)

    2011-01-01

    Source: US2012213698A The present invention relates to a novel composition and method for loading delivery systems such as liposome compositions with radionuclides useful in targeted diagnostic and/or therapy of target site, such as cancerous tissue and, in general, pathological conditions associ...... of positron emission tomography (PET) imaging technique. One specific aspect of the invention is directed to a method of producing nanoparticles with desired targeting properties for diagnostic and/or radio-therapeutic applications....

  8. Radionuclide Air Emission Report for 2009

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Linnea

    2010-06-01

    Berkeley Lab operates facilities where radionuclides are handled and stored. These facilities are subject to the EPA radioactive air emission regulations in 40CFR61, Subpart H (EPA 1989). Radionuclides may be emitted from stacks or vents on buildings where radionuclide production or use is authorized or they may be emitted as diffuse sources. In 2009, all Berkeley Lab sources were minor sources of radionuclides (sources resulting in a potential dose of less than 0.1 mrem/yr [0.001 mSv/yr]). These minor sources included more than 100 stack sources and one source of diffuse emissions. There were no unplanned emissions from the Berkeley Lab site. Emissions from minor sources (stacks and diffuse emissions) either were measured by sampling or monitoring or were calculated based on quantities used, received for use, or produced during the year. Using measured and calculated emissions, and building-specific and common parameters, Laboratory personnel applied the EPA-approved computer code, CAP88-PC, to calculate the effective dose equivalent to the maximally exposed individual (MEI). The effective dose equivalent from all sources at Berkeley Lab in 2009 is 7.0 x 10{sup -3} mrem/yr (7.0 x 10{sup -5} mSv/yr) to the MEI, well below the 10 mrem/yr (0.1 mSv/yr) dose standard. The location of the MEI is at the University of California (UC) Lawrence Hall of Science, a public science museum about 1500 ft (460 m) east of Berkeley Lab's Building 56. The estimated collective effective dose equivalent to persons living within 50 mi (80 km) of Berkeley Lab is 1.5 x 10{sup -1} person-rem (1.5 x 10{sup -3} person-Sv) attributable to the Lab's airborne emissions in 2009.

  9. Concrete Property and Radionuclide Migration Tests

    Energy Technology Data Exchange (ETDEWEB)

    Wellman, Dawn M.; Mattigod, Shas V.; Powers, Laura; Parker, Kent E.; Clayton, Libby N.; Wood, Marcus I.

    2008-10-01

    The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the DOE Complex. Part of theses services includes safe disposal of LLW and MLLW at the Hanford Low-Level Waste Burial Grounds (LLBG) in accordance with the requirements listed in DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, a Performance Assessment (PA) analyses were completed and approved. DOE Order 435.1 also requires that continuing data collection be conducted to enhance confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied upon to satisfy the performance objectives identified in the Order. One critical assumption is that concrete will frequently be used as waste form or container material to control and minimize the release of radionuclide constituents in waste into the surrounding environment. Data was collected to (1) quantify radionuclide migration through concrete materials similar to those used to encapsulate waste in the LLBG, (2) measure the properties of the concrete materials, especially those likely to influence radionuclide migration, and (3) quantify the stability of U-bearing solid phases of limited solubility in concrete.

  10. Radionuclide adsorption characteristics around coastal water

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young Il; Chung, Yang Geun; Hong, Sung Yul; Lee, Gab Bock [KEPCO, Taejon (Korea, Republic of)

    1999-07-01

    The adsorption capacity of radionuclides onto suspended sediment was experimented on each of the coastal seawater sampled around the Kori and the Wolsung nuclear power plant. During the experiment the quantity and size fraction of suspended sediment were adjusted and the seawater and sediment chemistry is approximated to the expected field condition. Because the sorption capacity depends on the specific minerals, ocean chemistry and radionuclide involved, it is necessary to analyze sediment mineralogy. Clay mineral is dominant in seabed mineral and suspended sediment as the result of x-ray diffraction. Radionuclide sorbed to silty-clay mineral can be rather transported to ocean than scavenged to seabed because of low quantity and fine grained suspended sediment in the coast around the Kori and the Wolsung. The result of adsorption examinations shows that {sup 139}Ce and {sup 51}Cr and {sup 110m}Ag are strongly sorbed to suspended particle, while {sup 137}Cs is less sorbed and {sup 60}Co uptake is varied with experiment condition, which can be inferred from various biological factors. (author). 9 refs., 2 tabs., 7 figs.

  11. Model for radionuclide transport in running waters

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Karin; Elert, Mark [Kemakta Konsult AB, Stockholm (Sweden)

    2005-11-15

    Two sites in Sweden are currently under investigation by SKB for their suitability as places for deep repository of radioactive waste, the Forsmark and Simpevarp/Laxemar area. As a part of the safety assessment, SKB has formulated a biosphere model with different sub-models for different parts of the ecosystem in order to be able to predict the dose to humans following a possible radionuclide discharge from a future deep repository. In this report, a new model concept describing radionuclide transport in streams is presented. The main difference from the previous model for running water used by SKB, where only dilution of the inflow of radionuclides was considered, is that the new model includes parameterizations also of the exchange processes present along the stream. This is done in order to be able to investigate the effect of the retention on the transport and to be able to estimate the resulting concentrations in the different parts of the system. The concentrations determined with this new model could later be used for order of magnitude predictions of the dose to humans. The presented model concept is divided in two parts, one hydraulic and one radionuclide transport model. The hydraulic model is used to determine the flow conditions in the stream channel and is based on the assumption of uniform flow and quasi-stationary conditions. The results from the hydraulic model are used in the radionuclide transport model where the concentration is determined in the different parts of the stream ecosystem. The exchange processes considered are exchange with the sediments due to diffusion, advective transport and sedimentation/resuspension and uptake of radionuclides in biota. Transport of both dissolved radionuclides and sorbed onto particulates is considered. Sorption kinetics in the stream water phase is implemented as the time scale of the residence time in the stream water probably is short in comparison to the time scale of the kinetic sorption. In the sediment

  12. Radionuclide content of Las Vegas wash sediments

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, M.J.; Meyers, A.M.; Johnson, W.H. [Univ. of Nevada, Las Vegas, NV (United States)

    1996-06-01

    The Las Vegas Wash is an excavated waterway channel which drains all surface water and effluent discharge from sewage-treatment facilities from the greater Las Vegas Metropolitan Area to Lake Mead. Runoff and erosion processes are expected to transport man-made radioactivity that was deposited over the past several decades in the Las Vegas Valley. Additionally, radionuclides disposed of via the city`s sanitary system are expected to accumulate in the Wash sediments. Fine and coarse sediment samples were collected at 100 m intervals and analyzed to determine the distribution of alpha- and gamma-emitting radionuclides in the lower 5,500 in of the Las Vegas Wash. Results indicate little accumulation of long-lived fission products in upstream Wash sediments. However, trace amounts of fission products measured in downstream sediments suggest the resuspension and transport of radioactive particulate matter within the Wash. Levels of naturally-occurring radionuclides found in Wash sediments were found to be consistent with levels typically found in southeast Nevada soils.

  13. Fungi and ionizing radiation from radionuclides.

    Science.gov (United States)

    Dighton, John; Tugay, Tatyana; Zhdanova, Nelli

    2008-04-01

    Radionuclides in the environment are one of the major concerns to human health and ecotoxicology. The explosion at the Chernobyl nuclear power plant renewed interest in the role played by fungi in mediating radionuclide movement in ecosystems. As a result of these studies, our knowledge of the importance of fungi, especially in their mycorrhizal habit, in long-term accumulation of radionuclides, transfer up the food chain and regulation of accumulation by their host plants was increased. Micro-fungi have been found to be highly resilient to exposure to ionizing radiation, with fungi having been isolated from within and around the Chernobyl plant. Radioresistance of some fungal species has been linked to the presence of melanin, which has been shown to have emerging properties of acting as an energy transporter for metabolism and has been implicated in enhancing hyphal growth and directed growth of sensitized hyphae towards sources of radiation. Using this recently acquired knowledge, we may be in a better position to suggest the use of fungi in bioremediation of radioactively contaminated sites and cleanup of industrial effluent.

  14. Radionuclide Partitioning in an Underground Nuclear Test Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Rose, T P; Hu, Q; Zhao, P; Conrado, C L; Dickerson, R; Eaton, G F; Kersting, A B; Moran, J E; Nimz, G; Powell, B A; Ramon, E C; Ryerson, F J; Williams, R W; Wooddy, P T; Zavarin, M

    2009-01-09

    In 2004, a borehole was drilled into the 1983 Chancellor underground nuclear test cavity to investigate the distribution of radionuclides within the cavity. Sidewall core samples were collected from a range of depths within the re-entry hole and two sidetrack holes. Upon completion of drilling, casing was installed and a submersible pump was used to collect groundwater samples. Test debris and groundwater samples were analyzed for a variety of radionuclides including the fission products {sup 99}Tc, {sup 125}Sb, {sup 129}I, {sup 137}Cs, and {sup 155}Eu, the activation products {sup 60}Co, {sup 152}Eu, and {sup 154}Eu, and the actinides U, Pu, and Am. In addition, the physical and bulk chemical properties of the test debris were characterized using Scanning Electron Microscopy (SEM) and Electron Microprobe measurements. Analytical results were used to evaluate the partitioning of radionuclides between the melt glass, rubble, and groundwater phases in the Chancellor test cavity. Three comparative approaches were used to calculate partitioning values, though each method could not be applied to every nuclide. These approaches are based on: (1) the average Area 19 inventory from Bowen et al. (2001); (2) melt glass, rubble, and groundwater mass estimates from Zhao et al. (2008); and (3) fission product mass yield data from England and Rider (1994). The U and Pu analyses of the test debris are classified and partitioning estimates for these elements were calculated directly from the classified Miller et al. (2002) inventory for the Chancellor test. The partitioning results from this study were compared to partitioning data that were previously published by the IAEA (1998). Predictions of radionuclide distributions from the two studies are in agreement for a majority of the nuclides under consideration. Substantial differences were noted in the partitioning values for {sup 99}Tc, {sup 125}Sb, {sup 129}I, and uranium. These differences are attributable to two factors

  15. Remediation of radionuclide pollutants through biosorption - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Das, Nilanjana [Environmental Biotechnology Division, School of Biosciences and Technology, VIT University, Vellore (India)

    2012-01-15

    The development of nuclear science and technology has led to the increase of nuclear wastes containing radionuclides to be released and disposed in the environment. Pollution caused by radionuclides is a serious problem throughout the world. To solve the problem, substantial research efforts have been directed worldwide to adopt sustainable technologies for the treatment of radionuclide containing wastes. Biosorption represents a technological innovation as well as a cost effective excellent remediation technology for cleaning up radionuclides from aqueous environment. A variety of biomaterials viz. algae, fungi, bacteria, plant biomass, etc. have been reported for radionuclide remediation with encouraging results. This paper reviews the achievements and current status of radionuclide remediation through biosorption which will provide insights into this research frontier. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Blood flow and tracer uptake in normal and abnormal canine bone: comparisons with Sr-85 microspheres, Kr-81m, and Tc-99m MDP

    Energy Technology Data Exchange (ETDEWEB)

    Lavender, J.P.; Khan, R.A.A.; Hughes, S.P.F.

    1979-05-01

    The bone scan, showing the 4-hr residue in bone of technetium diphosphonate, is a widely used diagnostic tool. The question arises whether it reflects changes in local blood flow to bone, or avidity, or both. Two experimental approaches have been used in trying to answer this question. The first was to determine immediate single-passage clearance and 4-hr residue in normal and abnormal bone. If flow is the determinant of residue these should be the same since, in this event, extraction will not change. An osteotomy was produced in the dog tibia and retrograde catheterization of the anterior tibial artery allowed measured amounts of technetium-methylene-diphosphonate (Tc-99m MDP), to be infused into the nutrient artery. Similar preparation in normal bone allowed comparison of both clearance and 4-hr residue. Results have shown increased 4-hr residue 10 days after the osteotomy (normal 4.9% ..-->.. 13.4%). The second approach involved use of a gamma camera to record profiles of blood flow in normal and abnormal bone: (a) by injecting Sr-85 microspheres into the nutrient artery, and (b) by infusing the short-lived radioactive gas, krypton-81m, thus producing an image of regional distribution of flow. Comparison of these profiles with the distribution of Tc-99m MDP shows that a moderate increase in flow is associated with a much greater increase in Tc-99m MDP residue. We conclude that, although blood flow is one determinant of the distribution of bone-seeking radionuclides such as Tc-99m MDP, some other determinants of clearance and residue explain their localization.

  17. Lung gallium scan

    Science.gov (United States)

    Gallium 67 lung scan; Lung scan; Gallium scan - lung; Scan - lung ... Gallium is injected into a vein. The scan will be taken 6 to 24 hours after the gallium is injected. (Test time depends on whether your condition is acute or chronic .) ...

  18. Sequential analysis of biochemical markers of bone resorption and bone densitometry in multiple myeloma

    DEFF Research Database (Denmark)

    Abildgaard, Niels; Brixen, Kim; Eriksen, Erik Fink

    2004-01-01

    BACKGROUND AND OBJECTIVES: Bone lesions often occur in multiple myeloma (MM), but no tests have proven useful in identifying patients with increased risk. Bone marker assays and bone densitometry are non-invasive methods that can be used repeatedly at low cost. This study was performed to evaluate...... 6 weeks, DEXA-scans performed every 3 months, and skeletal radiographs were done every 6 months as well as when indicated. RESULTS: Serum ICTP and urinary NTx were predictive of progressive bone events. Markers of bone formation, bone mineral density assessments, and M component measurements were...

  19. Mathematical simulation of sediment and radionuclide transport in estuaries

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Y.; Trent, D.S.

    1982-11-01

    The finite element model LFESCOT (Flow, Energy, Salinity, Sediment and Contaminant Transport Model) was synthesized under this study to simulate radionuclide transport in estuaries to obtain accurate radionuclide distributions which are affected by these factors: time variance, three-dimensional flow, temperature, salinity, and sediments. Because sediment transport and radionuclide adsorption/desorption depend strongly on sizes or types of sediments, FLESCOT simulates sediment and a sediment-sorbed radionuclide for the total of three sediment-size fractions (or sediment types) of both cohesive and noncohesive sediments. It also calculates changes of estuarine bed conditions, including bed elevation changes due to sediment erosion/deposition, and three-dimensional distributions of three bed sediment sizes and sediment-sorbed radionuclides within the bed. Although the model was synthesized for radionuclide transport, it is general enough to also handle other contaminants such as heavy metals, pesticides, or toxic chemicals. The model was checked for its capability for flow, water surface elevation change, salinity, sediment and radionuclide transport under various simple conditions first, confirming the general validity of the model's computational schemes. These tests also revealed that FLESCOT can use large aspect ratios of computational cells, which are necessary in handling long estuarine study areas. After these simple tests, FLESCOT was applied to the Hudson River estuary between Chelsea and the mouth of the river to examine how well the model can predict radionuclide transport through simulating tidally influenced three-dimensional flow, salinity, sediment and radionuclide movements with their interactions.

  20. Selected radionuclides important to low-level radioactive waste management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The purpose of this document is to provide information to state representatives and developers of low level radioactive waste (LLW) management facilities about the radiological, chemical, and physical characteristics of selected radionuclides and their behavior in the environment. Extensive surveys of available literature provided information for this report. Certain radionuclides may contribute significantly to the dose estimated during a radiological performance assessment analysis of an LLW disposal facility. Among these are the radionuclides listed in Title 10 of the Code of Federal Regulations Part 61.55, Tables 1 and 2 (including alpha emitting transuranics with half-lives greater than 5 years). This report discusses these radionuclides and other radionuclides that may be significant during a radiological performance assessment analysis of an LLW disposal facility. This report not only includes essential information on each radionuclide, but also incorporates waste and disposal information on the radionuclide, and behavior of the radionuclide in the environment and in the human body. Radionuclides addressed in this document include technetium-99, carbon-14, iodine-129, tritium, cesium-137, strontium-90, nickel-59, plutonium-241, nickel-63, niobium-94, cobalt-60, curium -42, americium-241, uranium-238, and neptunium-237.

  1. Transuranic radionuclides dispersed into the aquatic environment, a bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V.E.; Stoker, A.C.; Wong, Kai M. [and others

    1994-04-01

    The purpose of this project was to compile a bibliography of references containing environmental transuranic radionuclide data. Our intent was to identify those parameters affecting transuranic radionuclide transport that may be generic and those that may be dependent on chemical form and/or environmental conditions (i.e., site specific) in terrestrial, aquatic and atmospheric environments An understanding of the unique characteristics and similarities between source terms and environmental conditions relative to transuranic radionuclide transport and cycling will provide the ability to assess and predict the long term impact on man and the environment. An additional goal of our literature review, was to extract the ranges of environmental transuranic radionuclide data from the identified references for inclusion in a data base. Related to source term, these ranges of data can be used to calculate the dose to man from the radionuclides, and to perform uncertainty analyses on these dose assessments. On the basis of our reviews, we have arbitrarily outlined five general source terms. These are fallout, fuel cycle waste, accidents, disposal sites and resuspension. Resuspension of the transuranic radionuclides is a unique source term, in that the radionuclides can originate from any of the other source terms. If these transuranic radionuclides become resuspended into the air, they then become important as a source of inhaled radionuclides.

  2. Prosthetic joint infections: radionuclide state-of-the-art imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [AZ Alma Campus Sijsele, Department of Nuclear Medicine, Sijsele-Damme (Belgium); Wyngaert, Hans van den [AZ Alma Campus Sijsele, Department of Orthopaedic Surgery, Sijsele-Damme (Belgium); Love, Charito [Albert Einstein College of Medicine of Yeshiva University, Division of Nuclear Medicine and Radiology, Bronx, NY (United States); Welling, M.M. [Leiden University Medical Center, Scientist Molecular Imaging, Department of Radiology, Section of Nuclear Medicine C2-203, Leiden (Netherlands); Gemmel, Paul [Ghent University, The Faculty of Economics and Business Administration, Ghent (Belgium); Palestro, Christopher J. [Hofstra North Shore-Long Island Jewish Health System, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Hempstead, NY (United States)

    2012-05-15

    Prosthetic joint replacement surgery is performed with increasing frequency. Overall the incidence of prosthetic joint infection (PJI) and subsequently prosthesis revision failure is estimated to be between 1 and 3%. Differentiating infection from aseptic mechanical loosening, which is the most common cause of prosthetic failure, is especially important because of different types of therapeutic management. Despite a thorough patient history, physical examination, multiple diagnostic tests and complex algorithms, differentiating PJI from aseptic loosening remains challenging. Among imaging modalities, radiographs are neither sensitive nor specific and cross-sectional imaging techniques, such as computed tomography and magnetic resonance imaging, are limited by hardware-induced artefacts. Radionuclide imaging reflects functional rather than anatomical changes and is not hampered by the presence of a metallic joint prosthesis. As a result scintigraphy is currently the modality of choice in the investigation of suspected PJI. Unfortunately, there is no true consensus about the gold standard technique since there are several drawbacks and limitations inherent to each modality. Bone scintigraphy (BS) is sensitive for identifying the failed joint replacement, but cannot differentiate between infection and aseptic loosening. Combined bone/gallium scintigraphy (BS/GS) offers modest improvement over BS alone for diagnosing PJI. However, due to a number of drawbacks, BS/GS has generally been superseded by other techniques but it still may have a role in neutropenic patients. Radiolabelled leucocyte scintigraphy remains the gold standard technique for diagnosing neutrophil-mediated processes. It seems to be that combined in vitro labelled leucocyte/bone marrow scintigraphy (LS/BMS), with an accuracy of about 90%, is currently the imaging modality of choice for diagnosing PJI. There are, however, significant limitations using in vitro labelled leucocytes and considerable effort

  3. High-tension electrical injury to the heart as assessed by radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Iino, Hitoshi; Chikamori, Taishiro; Hatano, Tsuguhisa [Tokyo Medical Coll. (Japan)] [and others

    2002-12-01

    The purpose of this study was to evaluate cardiac complications associated with electrical injury, 7 patients with high-tension electrical injury (6,600 V alternating current) underwent {sup 201}Tl and {sup 123}I-metaiodobenzylguanidine (MIBG) imaging in addition to conventional electrocardiographic and echocardiographic assessments. Electrocardiography showed transient atrial fibrillation, second degree atrioventricular block, ST-segment depression, and sinus bradycardia in each patient. Echocardiography showed mild hypokinesis of the anterior wall in only 2 patients, but {sup 201}Tl and {sup 123}I-MIBG myocardial scintigraphy showed an abnormal scan image in 6/7 and 5/6 patients, respectively. Decreased radionuclide accumulation was seen primarily in areas extending from the anterior wall to the septum. Decreased radionuclide accumulation was smaller in extent and milder in degree in {sup 123}I-MIBG than in {sup 201}Tl imaging. These results suggest that even in patients without definite evidence of severe cardiac complications in conventional examinations, radionuclide imaging detects significant damage due to high-tension electrical injury, in which sympathetic nerve dysfunction might be milder than myocardial cell damage. (author)

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... limitations of the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan ... tissues in your body. top of page How is the procedure performed? Nuclear medicine imaging is usually ...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of the Thyroid Scan and Uptake? What is a Thyroid Scan and Uptake? A thyroid scan is ... code: Phone no: Thank you! Do you have a personal story about radiology? Share your patient story ...

  6. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  7. Natural radionuclides in mineral fertilizers and farmland

    Directory of Open Access Journals (Sweden)

    Mitrović Branislava M.

    2013-01-01

    Full Text Available Contemporary agriculture production is based on use of mineral fertilizers, which however can have high activity of natural radionuclides and so cause the appearance of technologically elevated radioactivity. In order to determine the influence of mineral fertilizers application in arable land, there was used gamma spectrometric method for defining the activity of natural radionuclides (40 K, 238U, 226Ra in imported mineral fertilizers as well as in arable and fallow land in the area of suburban municipalities of Belgrade. The obtained results have shown that in the tested mineral fertilizers the measured activity of 40K ranged from 70 to 4590 Bq/kg, 238U from 18 to 1400 Bq/kg and 226Ra from 15 to 999Bq/kg. Average activities of natural radionuclides in arable land are: 626 Bq/kg for 40K, 54 Bq/kg for 238U, 55 Bq/kg for 226Ra and 55Bq/kg for 232Th, and in fallow land 596 Bq/kg for 40K, 54 Bq/kg for 238U, 54 Bq/kg for 226Ra and 53 Bq/kg for 232Th. Average values of radium radioactivity equivalent (175 Bq/kg and index of radiation risk (0,48, point out that in the tested areas there is no significant radiation risk for inhabitants due to terrestrial exposure. This investigation has also shown that current use of mineral fertilizers has not caused the increase of natural radioactivity in the tested arable land. [Projekat Ministarstva nauke Republike Srbije, br. TR 31003

  8. Willow wood production on radionuclide polluted areas

    Directory of Open Access Journals (Sweden)

    Rodkin Oleg I.

    2010-01-01

    Full Text Available ABSTRACT: One of the key environmental problems in Belarus is effective use of agricultural lands contaminated by radionuclide due to the Chernobyl disaster. The alternative method to traditional agricultural crops is fast growing willow cultivation. It is possible to use biomass of willow as renewable energy source. The goal of our investigation was the estimation of environmental aspects of willow wood production on polluted areas. The field study experiments (2007-2010 were conducted at Krichev district of Mogilev region in eastern Belarus. This region characterized by high level of Cs-137 contamination as well as high level of heavy metals pollution. In the first stage of experiments, the concentration of cesium-137 in different parts of willow biomass had been measured and transfer factor calculated. The measuring had been done for leaves, roots, and wood. To control cesium-137 accumulation in willow biomass we apply different types (nitrogen N, phosphorus P and potassium K and dose of fertilizer. The experiments show that potassium mineral fertilizer is the key factor for radionuclide accumulation control. The optimal dose of potassium is 90 kg per hectare. On the base of experimental results the model of cesium-137 accumulation in the wood for a 21 year has been developed. In accordance with calculation to the end of willow cultivation (21 year concentration of cesium-137 in wood will not be higher than permitted even with the level of cesium-137 contamination in the soil 1480 kBq/m2 (maximum 140 kqB/m2 with permitted level for firewood is 740 Bq/kg.. The concentration of cesium-137 in the roots increases gradually and get maximum in 21 year (3000 kqB/m2. Our results confirm that in the sum about 0.8 million hectares of radionuclide polluted arable lands partly excluded from agricultural practice in Belarus could be used for willow biomass production.

  9. Identification of radionuclides for the spectroscopic radiation portal monitor for pedestrian screening under a low signal-to-noise ratio condition

    Energy Technology Data Exchange (ETDEWEB)

    Min, Eungi [Department of IT Convergence, Korea University, Seoul (Korea, Republic of); School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Ko, Mincheol [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Department of Bio-convergence Engineering, Korea University, Seoul (Korea, Republic of); Lee, Hakjae [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Research Institute of Health Science, Korea University, Seoul (Korea, Republic of); Kim, Yongkwon [NuCare Medical Systems, Incheon (Korea, Republic of); Research Institute of Health Science, Korea University, Seoul (Korea, Republic of); Joung, Jinhun [NuCare Medical Systems, Incheon (Korea, Republic of); Joo, Sung-Kwan [School of Electrical Engineering, Korea University, Seoul (Korea, Republic of); Lee, Kisung, E-mail: kisung@korea.ac.kr [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Department of Bio-convergence Engineering, Korea University, Seoul (Korea, Republic of); Department of Medical Devices, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2014-09-11

    The spectroscopic radiation portal monitor (SPM) is widely used for homeland security. Many research groups are studying the radionuclide identification method which is one of the most important factors in the performance of the SPM using the large size of a thallium activated sodium iodide (NaI(Tl)) detector. In this study, we developed the radionuclide identification method for the SPM for pedestrian screening using a single NaI(Tl) detector that is small in size (2 in.), which is much smaller than those in the existing studies under the low signal-to-noise-ratio (SNR) condition. From the anomalous radionuclide spectrum, the noise component was effectively reduced by the wavelet decomposition and the proposed background subtraction method, and the signal component was enhanced by the principal component analysis. Finally, peak locations which have been determined by the peak search algorithm with a valley check method were compared with a pre-calibrated and constructed radionuclide database. To verify the radiation identification performance of the proposed method, experiments with various kinds of sources ({sup 137}Cs, {sup 133}Ba, {sup 22}Na, and {sup 57}Co) and different SNR values (from distances of 10–150 cm and for scan times of 1–5 s) were performed. Although the high-SNR condition was explored as well, most experiments were conducted under the low-SNR condition to verify the robustness and reproducibility of the proposed algorithm. The results showed that over 98.3% of the single radionuclide detection rate was achieved regardless of which radionuclides were used, up to 50 cm under the worst SNR condition (1 s of scan time) and up to 90 cm under the best SNR condition (5 s of scan time). Furthermore we achieved accurate identification of multiple radionuclides at 40 cm with only 1 s of scan time. The results show that the proposed algorithm is competitive with the commercial method and our radionuclide identification method can be successfully applied

  10. Transfer of radionuclides from high polluted bottom sediments to marine organisms through benthic food chain in post Fukushima period

    Science.gov (United States)

    Bezhenar, Roman; Jung, Kyung Tae; Maderich, Vladimir; Willemsen, Stefan; de With, Govert; Qiao, Fangli

    2015-04-01

    accumulates in a specific tissue called target tissue. This tissue (bone, flesh, stomach, and organs) controls the overall elimination rate of the nuclide in the organism. The model prediction for the coastal area around the FDNPP agree well with observations. In addition the effects from the Chernobyl accident on the Baltic Sea are modelled and these results also are in good agreement with available data. These results demonstrate the importance of the benthic food chain in long-term transfer of radionuclides from high polluted bottom sediments to the marine organisms. The developed model can be applied for different regions of the World Ocean.

  11. Radionuclides in the Great Lakes basin.

    Science.gov (United States)

    Ahier, B A; Tracy, B L

    1995-12-01

    The Great Lakes basin is of radiologic interest due to the large population within its boundaries that may be exposed to various sources of ionizing radiation. Specific radionuclides of interest in the basin arising from natural and artificial sources include 3H, 14C, 90Sr, 129I, 131I, 137Cs, 222Rn, 226Ra, 235U, 238U, 239Pu, and 241Am. The greatest contribution to total radiation exposure is the natural background radiation that provides an average dose of about 2.6 mSv/year to all basin residents. Global fallout from atmospheric nuclear weapons tests conducted before 1963 has resulted in the largest input of anthropogenic radioactivity into the lakes. Of increasing importance is the radionuclide input from the various components of the nuclear fuel cycle. Although the dose from these activities is currently very low, it is expected to increase if there is continued growth of the nuclear industry. In spite of strict regulations on design and operation of nuclear power facilities, the potential exists for a serious accident as a result of the large inventories of radionuclides contained in the reactor cores; however, these risks are several orders of magnitude less than the risks from other natural and man-made hazards. An area of major priority over the next few decades will be the management of the substantial amounts of radioactive waste generated by nuclear fuel cycle activities. Based on derived risk coefficients, the theoretical incidence of fatal and weighted nonfatal cancers and hereditary defects in the basin's population, attributable to 50 years of exposure to natural background radiation, is conservatively estimated to be of the order of 3.4 x 10(5) cases. The total number of attributable health effects to the year 2050 from fallout radionuclides in the Great Lakes basin is of the order of 5.0 x 10(3). In contrast, estimates of attributable health effects from 50 years of exposure to current nuclear fuel cycle effluent in the basin are of the order of 2

  12. Naturally occurring radionuclides and Earth sciences

    Directory of Open Access Journals (Sweden)

    G. Ferrara

    1997-06-01

    Full Text Available Naturally occurring radionuclides are used in Earth sciences for two fundamental purposes: age determination of rocks and minerals and studies of variation of the isotopic composition of radiogenic nuclides. The methodologies that are in use today allow us to determine ages spanning from the Earth's age to the late Quaternary. The variations of isotopic composition of radiogenic nuclides can be applied to problems of mantle evolution, magma genesis and characterization with respect to different geodynamic situations and can provide valuable information not obtainable by elemental geochemistry.

  13. ACCELERATIVE AND RADIONUCLIDE TECHNOLOGIES IN CLINICAL MEDICINE

    Directory of Open Access Journals (Sweden)

    A. P. Chernyaev

    2016-01-01

    Full Text Available Methods based on accelerative and radionuclide technologies are more and more invading clinical practice of modern medicine. The aim of this review is to demonstrate the role of nuclear physics techniques for treatment and diagnostics of various disorders. We analyzed data published in the last 50 years in research papers, reports and other open sources considering particulars of electron accelerators and heavy charged particles in radiation and nuclear medicine and presenting the information on prevalence of accelerators and other high-tech medical equipment in Russia and worldwide.

  14. Radionuclides at Descartes in the central highlands

    Science.gov (United States)

    Wrigley, R. C.

    1973-01-01

    Throium, uranium, potassium, aluminium-26, and sodium-22 were measured by nondestructive gamma ray spectrometry in six soil and two rock samples gathered by Apollo 16 in the lunar central highlands. The soil samples probably include both major geologic formations in the vicinity, the Cayley and Descartes Formations, although it is possible that the Descartes Formation is not represented. The rock samples have low concentrations of primordial radionuclides. The Al concentrations were lower than could be expected from the high abundance of alumina in the Apollo 16 soils reported earlier, but this could be due to lower concentrations of target elements in these soils, sampling depth variations, or regolithic mixing (exposure age variations).

  15. Preparation of radiopharmaceuticals labeled with metal radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1992-06-01

    We recently developed a useful zinc-62/copper-62 generator and are presently evaluating copper-62 radiopharmaceuticals for clinical studies. While developing these copper-62 radiopharmaceuticals, in collaboration with the University of Missouri Research Reactor, Columbia we have also explored copper-64 radiopharmaceuticals. The PET images we obtained with copper-64 tracers were of such high quality that we have developed and evaluated copper-64 labeled antibodies for PET imaging. The major research activities described herein include: the