WorldWideScience

Sample records for radionuclide bone scan

  1. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    Technetium-99m methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan intake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the ''extended pattern of uptake'' beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogenous uptake on the scan

  2. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    /sup 99m/Tc methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan uptake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the extended pattern of uptake beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogeneous uptake on the scan

  3. Radionuclides and the normal bone scan

    International Nuclear Information System (INIS)

    Mettler, F.A. Jr.; Monsein, L.; Rosenberg, R.D.

    1988-01-01

    Recently, Eisenhut and co-workers have described development of iodine-131 labeled diphosphonates for palliative treatment of bone metastases. The compound labeled was alpha-amino (4-hydroxybenzylidene) diphosphonate (BDP3). Other beta-emitting radionuclides have been used for treatment of intractable pain secondary to bone metastases. These include strontium-89, which has some difficulties, particularly in terms of disposal of the excretions due to the long physical half-life of the life of the radionuclide. Yttrium-90 has also been used but has a relatively high hepatic uptake. Phosphorus-32 labeled compounds have also been used. Although palliation has been described, bone marrow depression has also occurred. Rhenium-186 also has been suggested, however, high renal uptake is a problem. At present, the iodine-131 labeled BDP3 appears to be the best of the available therapeutic radiopharmaceuticals. One of the major disadvantages in use of this compound is the production of gamma photons. While undesirable from a dosimetry viewpoint, gamma photons do, however, permit imaging if desired

  4. Clinical significant of three phase radionuclide bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Suh, Jin Suck; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-04-15

    Three phase radionuclide bone scan, consisting of a radionuclide angiogram, an immediate postinjection blood pool image, and 4hr delayed images, was randomly performed in 182 patients, who had been suffered from either local pain or tenderness. Authors analysed 3 phase bone scan in 74 patients with correct diagnosis proven surgically or clinically, from July 1987 to August, 1988. The results were as follows: 1. Overall sensitivity of 3 phase bone scan was 85.4%: sensitivity in patients with an osseous lesion was 90.4% as opposed to 72.7% in patients with a nonosseous lesion. 2. There was no difference in the detection rate of the osseous lesions between the 3 phase bone scan and the delayed image bone scan. However, because the detection rate was higher on the 3 phase bone scan than it was on only the delayed image bone scan (55%) in instance of the nonosseous lesion, we would suggest that 3 phase bone scan might be obtained in cases suspected of the nonosseous lesions. 3. When the presumptive diagnosis was a bone tumor, sensitivity and specificity for malignancy were 67%, 100% respectively. 4. In differentiating osteomyelitis from cellulitis, sensitivity was 94%, specificity was 100%. 5. 3 phase bone scan was able to provide the precise information about either vasculaturity or localization of lesion in some cases of soft tissue mass and avascular necrosis of hips.

  5. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  6. Radiographic skeletal survey and radionuclide bone scan in Langerhans cell histiocytosis of bone

    International Nuclear Information System (INIS)

    Nieuwenhuyse, J.P. van; Clapuyt, P.; Malghem, J.; Everarts, P.; Melin, J.; Pauwels, S.; Brichard, B.; Ninane, J.; Vermylen, C.; Cornu, G.

    1996-01-01

    Background. The lack of a consensus in the literature on the imaging strategy in Langerhans cell histiocytosis (LCH) bone lesions in childhood. Objective. To evaluate the relative value of radionuclide bone scan (RBS) and radiographic skeletal survey (RSS) in the detection of LCH bone lesions, both in the initial work-up of the disease and during the follow-up period. Materials and methods. Ten children with bone lesions evaluated by means of RSS and RBS in a retrospective study (1984-1993). Results. Fifty radiologically and/or scintigraphically abnormal foci were detected: 27 anomalies in the initial work-up (12 by both RSS and RBS, 8 by RSS only and 7 by RBS only) and 23 additional anomalies during follow-up (10 by both RSS and RBS, 10 by RSS only and 3 by RBS only). RSS+/RBS- lesions (n = 18) are more frequently encountered in the skull (P = 0.038), and more frequently lack radiologic signs of osteoblastic activity (P = 0.020), than RSS+/RBS+ lesions (n = 22). RSS-/RBS+ abnormalities (n = 10) were most frequently insignificant. Conclusion. In the initial work-up both RSS and RBS should be carried out, while in the follow-up only RSS should be performed. (orig.). With 2 figs., 4 tabs

  7. Changes observed in radionuclide bone scans during and after teriparatide treatment for osteoporosis

    International Nuclear Information System (INIS)

    Moore, Amelia E.B.; Blake, Glen M.; Fogelman, Ignac; Taylor, Kathleen A.; Ruff, Valerie A.; Rana, Asad E.; Wan, Xiaohai

    2012-01-01

    Visual changes on radionuclide bone scans have been reported with teriparatide treatment. To assess this, serial studies were evaluated and quantified in ten postmenopausal women with osteoporosis treated with teriparatide (20 μg/day subcutaneous) who had 99m Tc-methylene diphosphonate (MDP) bone scans (baseline, 3 and 18 months, then after 6 months off therapy). Women were injected with 600 MBq 99m Tc-MDP, and diagnostic bone scan images were assessed at 3.5 h. Additional whole-body scans (10 min, 1, 2, 3 and 4 h) were analysed for 99m Tc-MDP skeletal plasma clearance (K bone ). Regional K bone differences were obtained for the whole skeleton and six regions (calvarium, mandible, spine, pelvis, upper and lower extremities). Bone turnover markers (BTM) were also measured. Most subjects showed visual changes on 3- and 18-month bone scan images that disappeared after 6 months off therapy. Enhanced uptake was seen predominantly in the calvarium and lower extremities. Whole skeleton K bone displayed a median increase of 22% (3 months, p = 0.004) and 34% (18 months, p = 0.002) decreasing to 0.7% (6 months off therapy). Calvarium K bone changes were three times larger than other sites. After 6 months off therapy, all K bone and BTM values returned towards baseline. The increased 99m Tc-MDP skeletal uptake with teriparatide indicated increased bone formation which was supported by BTM increases. After 6 months off therapy, metabolic activity diminished towards baseline. The modulation of 99m Tc-MDP skeletal uptake during treatment was the result of teriparatide's metabolic activity. These findings may aid the radiological evaluation of similar teriparatide patients having radionuclide bone scans. (orig.)

  8. Changes observed in radionuclide bone scans during and after teriparatide treatment for osteoporosis

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Amelia E.B.; Blake, Glen M.; Fogelman, Ignac [King' s College London, School of Medicine, Department of Nuclear Medicine, London (United Kingdom); Taylor, Kathleen A.; Ruff, Valerie A.; Rana, Asad E.; Wan, Xiaohai [Eli Lilly and Company, Indianapolis, IN (United States)

    2012-02-15

    Visual changes on radionuclide bone scans have been reported with teriparatide treatment. To assess this, serial studies were evaluated and quantified in ten postmenopausal women with osteoporosis treated with teriparatide (20 {mu}g/day subcutaneous) who had {sup 99m}Tc-methylene diphosphonate (MDP) bone scans (baseline, 3 and 18 months, then after 6 months off therapy). Women were injected with 600 MBq {sup 99m}Tc-MDP, and diagnostic bone scan images were assessed at 3.5 h. Additional whole-body scans (10 min, 1, 2, 3 and 4 h) were analysed for {sup 99m}Tc-MDP skeletal plasma clearance (K{sub bone}). Regional K{sub bone} differences were obtained for the whole skeleton and six regions (calvarium, mandible, spine, pelvis, upper and lower extremities). Bone turnover markers (BTM) were also measured. Most subjects showed visual changes on 3- and 18-month bone scan images that disappeared after 6 months off therapy. Enhanced uptake was seen predominantly in the calvarium and lower extremities. Whole skeleton K{sub bone} displayed a median increase of 22% (3 months, p = 0.004) and 34% (18 months, p = 0.002) decreasing to 0.7% (6 months off therapy). Calvarium K{sub bone} changes were three times larger than other sites. After 6 months off therapy, all K{sub bone} and BTM values returned towards baseline. The increased {sup 99m}Tc-MDP skeletal uptake with teriparatide indicated increased bone formation which was supported by BTM increases. After 6 months off therapy, metabolic activity diminished towards baseline. The modulation of {sup 99m}Tc-MDP skeletal uptake during treatment was the result of teriparatide's metabolic activity. These findings may aid the radiological evaluation of similar teriparatide patients having radionuclide bone scans. (orig.)

  9. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  10. A comparative study of radionuclide bone scan, X-ray and MRI on early femoral head necrosis in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Ji Qinglian; Xu Aide; Zuo Shuyao; Gao Zhenhua

    2004-01-01

    Objective: To summarize radionuclide bone scan signs in the early femoral head necrosis (FHN) in adults, to compare them with MRI and X-ray findings and to discuss the pathological basis of radionuclide bone scan findings from the view of MRI. Methods: Forty cases (63 hips) with early FHN in adult patients proved by follow-up studies or pathology were analyzed. All patients underwent radionuclide bone scan, MRI and X-ray examination within a period of less than 7 d separately. Results: 1) Radionuclide bone scan manifestations of the early FHN corresponding to different MRI signs included: focally decreased uptake of radioisotope, focally increased uptake, atypical or typical doughnut sign, mildly increased uptake in the superior part of femoral head with band-like region of obviously increased uptake in inferior part of femoral head or femoral neck, and diffused increase of uptake in the whole head. 2) In 40 cases (63 hips), there was statistical difference in diagnosis early FHN in adults not only between radionuclide bone scan and X-ray but also between MRI and X-ray in sensitivity (P 0.05). Conclusions: 1) The atypical or typical doughnut sign and mildly increased uptake in the superior part of femoral head with band-like region of obviously increased uptake in inferior part of femoral head or neck are specific signs for diagnosing early FHN. 2) For sensitivity, radionuclide bone scan and MRI are equally superior to X-ray. (authors)

  11. Gastric visualization and image quality in radionuclide bone scanning: concise communication

    International Nuclear Information System (INIS)

    Wilson, M.A.; Pollack, M.J.

    1981-01-01

    In a 12-mo study period, there were 14 days identified when the stomach was visualized in routine bone imaging. On these days, 44% of the 110 patients imaged demonstrated this effect. There was a significant linear correlation between the presence and degree of gastric visualization and the radiopharmaceutical incubation and quality control parameters. The study suggests a sporadic phenomenon that appears to result from partial oxidation of the agent during incubation, producing (a) different species of labeled diphosphonate that display altered affinity for bone (scan quality) and (b) free pertechnetate

  12. The natural course of radionuclide bone scanning in the evaluation of total knee replacement--a 2 year prospective study

    DEFF Research Database (Denmark)

    Duus, B R; Boeckstyns, M; Stadeager, Carsten Preben

    1990-01-01

    In order to establish the natural course of radionuclide bone scanning images after total knee replacement 41 consecutive patients were scheduled for examination 3, 7, 12 and 24 months after surgery. The mean age was 69 years (range 50-80 years); the female:male ratio was 4:1. Thirty-two patients...... completed the entire program. A total of 143 99Tcm medronic acid complex scintigrams was performed. No significant difference between the grades of total scintigraphic uptake at any of the four examinations nor any difference between the first and the last examinations could be demonstrated (P = 0...

  13. Gastric visualization and image quality in radionuclide bone scanning: concise communication

    International Nuclear Information System (INIS)

    Wilson, M.A.; Pollack, M.J.

    1981-01-01

    In a 12-mo study period, there were 14 days identified when the stomach was visualized in routine bone imaging. On these days, 44% of the 110 patients imaged demonstrated this effect. Only the quality control, binding efficiency, and scan quality differed (p less than 0.005) when the study population was compared with a reference population of 162 patients. However, on the days when this effect was noted, there was a significant (p less than 0.001) linear correlation between the presence and degree of gastric visualization and the radiopharmaceutical incubation and quality control parameters. The study suggests a sporadic phenomenon that appears to result from partial oxidation of the agent during incubation, producing (a) different species of labeled diphosphonate that display altered affinity for bone (scan quality) and (b) free pertechnetate

  14. Multiple myeloma: radiology or bone scanning

    International Nuclear Information System (INIS)

    Leonard, R.C.F.; Owen, J.P.; Proctor, S.J.; Hamilton, P.J.

    1981-01-01

    A comparative study of radionuclide bone scanning and skeletal radiology in patients with multiple myeloma revealed four principal findings: (i) There were no cases of negative bone scans with positive skeletal radiographs. (ii) Lytic bone lesions were seriously underestimated by bone scans. (iii) Bone scans tended to pick up lesions in ribs missed on the skeletal surveys. (iv) Patients with bone pain were more likely to have positive bone scans and skeletal radiographs than asymptomatic patients. (author)

  15. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  16. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  17. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    Directory of Open Access Journals (Sweden)

    Nnamdi Norbert Jibiri

    2016-10-01

    Full Text Available Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP without cannula and with cannula were 10.68 (720.2 and 13.82 (556.4 mSv per week (and per annum, respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99m

  18. Comparison of radionuclide bone scan with radiographic skeletal survey in detecting metastases in neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Tani, G.; Lucchi, A.; Pisi, P.; Boriani, F.; De Florio, L.; Turba, E.; Mancini, A.F.; Marchi, N.; Rossi, M.

    1987-10-01

    Neuroblastoma (NBL) with bone metastasis is in its IV (fourth) stage of development. In this study we discuss the radiological and scintigraphic data of 25 patients with neuroblastoma in the IV stage at diagnosis. All the patients had undergone a radiological examination of the whole skeleton and a bone scintigraphy. The aim of this work is to compare the sensitivity of the two methods. The authors conclude that both the examinations are important and complementary to define the IV stage of the disease to avoid underevaluations.

  19. Comparison of radionuclide bone scan with radiographic skeletal survey in detecting metastases in neuroblastoma

    International Nuclear Information System (INIS)

    Tani, G.; Lucchi, A.; Pisi, P.; Boriani, F.; De Florio, L.; Turba, E.; Mancini, A.F.; Marchi, N.; Rossi, M.

    1987-01-01

    Neuroblastoma (NBL) with bone metastasis is in its IV (fourth) stage of development. In this study we discuss the radiological and scintigraphic data of 25 patients with neuroblastoma in the IV stage at diagnosis. All the patients had undergone a radiological examination of the whole skeleton and a bone scintigraphy. The aim of this work is to compare the sensitivity of the two methods. The authors conclude that both the examinations are important and complementary to define the IV stage of the disease to avoid underevaluations. (orig.) [de

  20. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  1. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  2. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  3. Scanning of bone metastases

    International Nuclear Information System (INIS)

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  4. Study on the serum levels of relevant cytokines IL-β, IL-6, IL-8 and tumor markers CEA, CA15-3, PRL in breast cancer patients with bone metastatic lesions shown on SPECT radio-nuclide bone scan

    International Nuclear Information System (INIS)

    Zhu Bao

    2009-01-01

    Objective: To explore the correlationship between SPECT radionuclide bone scan and serum levels of three tumor markers as well as three cytokines in patients with breast cancer. Methods: Serum levels of IL-1β, IL-6, IL-8, CEA, CA15-3(with RIA) and PRL(with CLIA) were determined in 1)20 breast cancer patients with definite bone metastatic lesions shown on radio-nuclide bone scan 2) 20 breast cancer patients without bone metastasis 3) 30 patients with benign breast disorders and 4) 35 controls. Results: The serum tumor markers levels in patients osseous metastasis were significantly higher than those in the other three groups (P 0.05). The serum levels of IL-6, IL-8, IL-1β in patients with osseous metastasis were also significantly higher than those in other groups(P<0.05). Conclusion: Over expression of CEA, CA15-3 and PRL as well as IL-6, IL-8, IL-1β were related with osseous metastasis from breast cancer. Determination of the levels of these six parameters would be helpful for dynamic monitoring of the extent of metastasis. (authors)

  5. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  6. Role of bone scanning in neonatal rickets

    Energy Technology Data Exchange (ETDEWEB)

    Saul, P.D.; Lloyd, D.J.; Smith, F.W.

    1983-03-01

    Preterm infants are at increased risk from rickets. Radionuclide bone scanning is a useful aid in suspected cases. It offers advantages over conventional radiology in terms of sensitivity, radiation dose and extent of examination. Unsuspected fractures of clinical or medicolegal significance may be detected. Two cases are described in which the technique confirmed the diagnosis and assisted management.

  7. Bone scanning in patients with breast carcinoma

    International Nuclear Information System (INIS)

    Inoue, Y.; Nishi, T.; Hirose, T.; Schichijo, Y.; Ibukuro, K.

    1985-01-01

    Skeletal imaging using radionuclides has proved to be a sensitive method for the detection of early bony metastases from breast carcinoma. Recent studies have found a relatively low rate of abnormal scans in patients with stage I and II breast cancers, and therefore it is open to question whether bone scanning should be part of the preoperative evaluation of any patient prior to breast surgery. We reviewed our experience with bone scans in 329 patients out of 406 histologically proven breast cancer patients to determine if any or all patients should have this procedure done routinely prior to breast surgery. (orig.) [de

  8. The clinical research of bone scan in patients with fibrous dysplasia of bone

    International Nuclear Information System (INIS)

    Yuan Zhibin; Yu Jianfang; Luo Quanyong; Lu Hankui; Zhu Jifang; Zhu Ruisen

    2002-01-01

    Objective: To study the characteristics of fibrous dysplasia of bone in bone imaging and evaluate the diagnostic value of radionuclide bone scan in fibrous dysplasia of bone. Methods: All 42 cases of fibrous dysplasia of bone patients had radionuclide bone scan performed and compared with other imaging modalities. A retrospective study method was used to analyze the imaging results. Results: Although fibrous dysplasia of bone showed uptake of 99m Tc-MDP in the images, its appearance characteristic was different from those metastatic bone tumors and other bone diseases. Combining with X rays and other imaging modalities can improve the diagnostic accuracy of this disease. Conclusion: Radionuclide bone scan has got certain value in the diagnosis of fibrous dysplasia of bone. Combining with other imaging modality can make up its disadvantage of low specificity

  9. Radionuclide bone image in growing and stable bone island

    International Nuclear Information System (INIS)

    Go, R.T.; El-Khoury, G.Y.; Iowa Univ., Iowa City; Wehbe, M.A.

    1980-01-01

    A normal radionuclide bone image can facilitate distinction between a bone island and significant pathologic processes, especially an osteoblastic metastasis. This distinction becomes more crucial when growth is detected in an isolated sclerotic bone lesion or if a relatively large sclerotic lesion is detected de novo in patients with a known neoplasm. This report presents three patients with isolated bone islands: two with interval growth, the other with a relatively large stable lesion; all showing a normal radionuclide bone image. (orig.) [de

  10. Bone scan features in spontaneous knee pain.

    Science.gov (United States)

    Vattimo, A; Merlo, F; Bertelli, P; Burroni, L

    1992-01-01

    In 21 patients with "spontaneous" knee pain, 99mTc-MDP bone scan was found to be more sensitive than clinical and radiographic examination in detecting alterations of the joint components. These alterations were shown by increased radionuclide uptake in the compartments where pain was present, which was most commonly the medial femorotibial compartment, although the femoropatellar compartment was also frequently affected. The authors conclude that bone scan should be the first imaging study performed on the knee in order to establish if further tests are necessary.

  11. Radioisotope bone scanning in horses

    International Nuclear Information System (INIS)

    Attenburrow, D.P.; Bowring, C.S.; Vennart, W.

    1984-01-01

    The detection of radionuclide activity in the living equine skeleton, using bone seeking radiopharmaceuticals and a hand-held radiation detector, is reported. Pathological changes in bone can be detected and subsequent development monitored. The availability and use of this diagnostic technique in equine practice is discussed

  12. Bone scan indications in oncology

    International Nuclear Information System (INIS)

    Rocha, A.F.G. da; Marquiotti, M.

    1986-01-01

    The scintigraphic method is described and a critical analysis of its value in the research of bone metastases is presented. The method validity, the positivity of bone scan for metastases at the first examination and the preferencial distribution metastases in skeleton are related.Bone pain and the results of bone scintigram are correlated. (M.A.C.) [pt

  13. Metastatic calcification of the stomach imaged on a bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, R.; Ryo, U.Y.; Pinsky, S.M.

    1984-10-01

    A whole body bone scan obtained on a 21-year-old woman with sickle cell disease and chronic renal failure showed localization of the radionuclide diffusely in the stomach. The localization of the radionuclide represented metastatic calcification of the stomach caused by secondary hyperparathyroidism.

  14. Bone Densitometry (Bone Density Scan)

    Science.gov (United States)

    ... made of metal. Objects such as keys or wallets that would be in the area being scanned should be removed. You will ... and are often available in drugstores and on mobile health vans in the community. The pDEXA device is much smaller than ...

  15. Factors influencing bone scan quality

    International Nuclear Information System (INIS)

    Adams, F.G.; Shirley, A.W.

    1983-01-01

    A reliable subjective method of assessing bone scan quality is described. A large number of variables which theoretically could influence scan quality were submitted to regression and factor analysis. Obesity, age, sex and abnormality of scan were found to be significant but weak variables. (orig.)

  16. Comparative study on skull CT scan and bone scintigraphy in chronic hemodialysed patients

    International Nuclear Information System (INIS)

    Ochi, Hironobu; Inoue, Yuichi; Fukuda, Teruo; Shibakiri, Ippei; Tsuda, Kazuyoshi

    1981-01-01

    A comparative study of computed tomography (XCT) scan utilizing EMI head unit and radionuclide bone scan was performed in 17 patients with chronic renal failure on maintenance hemodialysis. Bone scintigram was positive in 7 out of 17 patients. EMI number of the skull in the positive bone scintigram group was significantly lower than that of the negative bone scintigram. Radionuclide bone scan is the most useful method to detect early bone change and XCT scan will determine the grade of the bone mineral contents. XCT is especially useful to follow patients under the medical treatment (active vitamine D 3 therapy) in order to know the therapeutic effect. (author)

  17. Sequential radionuclide bone imaging in avascular pediatric hip conditions

    International Nuclear Information System (INIS)

    Minikel, J.; Sty, J.; Simons, G.

    1983-01-01

    Radionuclide bone imaging was performed on six patients with various hip conditions. Initial bone images revealed diminished uptake of isotope /sup 99m/Tc-MDP in the capital femoral epiphysis. Following therapeutic intervention, repeat bone scans revealed normal uptake of /sup 99m/Tc-MDP in the capital femoral epiphysis. Subsequent radiographs revealed that avascular necrosis had not occurred. There are two types of avascularity: the potentially reversible, and the irreversible. Attempts should be made toward early recognition of the potentially reversible avascular insult. With early recognition, surgical reconstruction prior to osteophyte death may result in revascularization. If this can be accomplished, avascular necrosis can be avoided

  18. Scanning electron microscopy of bone.

    Science.gov (United States)

    Boyde, Alan

    2012-01-01

    This chapter described methods for Scanning Electron Microscopical imaging of bone and bone cells. Backscattered electron (BSE) imaging is by far the most useful in the bone field, followed by secondary electrons (SE) and the energy dispersive X-ray (EDX) analytical modes. This chapter considers preparing and imaging samples of unembedded bone having 3D detail in a 3D surface, topography-free, polished or micromilled, resin-embedded block surfaces, and resin casts of space in bone matrix. The chapter considers methods for fixation, drying, looking at undersides of bone cells, and coating. Maceration with alkaline bacterial pronase, hypochlorite, hydrogen peroxide, and sodium or potassium hydroxide to remove cells and unmineralised matrix is described in detail. Attention is given especially to methods for 3D BSE SEM imaging of bone samples and recommendations for the types of resin embedding of bone for BSE imaging are given. Correlated confocal and SEM imaging of PMMA-embedded bone requires the use of glycerol to coverslip. Cathodoluminescence (CL) mode SEM imaging is an alternative for visualising fluorescent mineralising front labels such as calcein and tetracyclines. Making spatial casts from PMMA or other resin embedded samples is an important use of this material. Correlation with other imaging means, including microradiography and microtomography is important. Shipping wet bone samples between labs is best done in glycerol. Environmental SEM (ESEM, controlled vacuum mode) is valuable in eliminating -"charging" problems which are common with complex, cancellous bone samples.

  19. Interesting bone scans - unusual findings

    International Nuclear Information System (INIS)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.

    1997-01-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  20. Bone stress: a radionuclide imaging perspective

    International Nuclear Information System (INIS)

    Roub, L.W.; Gumerman, L.W.; Hanley, E.N. Jr.; Clark, M.W.; Goodman, M.; Herbert, D.L.

    1979-01-01

    Thirty-five college athletes with lower leg pain underwent radiography and radionuclide studies to rule out a stress fracture. Their asymptomatic extremities and 13 pain-free athletes served as controls. Four main patterns were observed: (a) sharply marginated scintigraphic abnormalities and positive radiographs; (b) sharply marginated scintigraphic abnormalities and negatives radiographs; (c) ill-defined scintigraphic abnormalities and negative radiographs; and (d) negative radionuclide images and negative radiographs. Since the patients with the first two patterns were otherwise identical medically, the authors feel that this scintigraphic appearance is characterisic of bone stress in the appropriate clinical setting, regardless of the radiographic findings. A schema is proposed to explain the occurrence of positive radionuclide images and negative radiographs in the same patient, using a broad conceptual approach to the problem of bone stress

  1. Bone scanning in the child and young adult. Pt. 2

    Energy Technology Data Exchange (ETDEWEB)

    Murray, I P.C. [Prince of Wales Hospital, Randwick (Australia). Dept. of Nuclear Medicine

    1980-01-01

    The sensitivity of the radionuclide bone scan in identifying osteoblastic reaction in bone and in detecting local alterations in blood flow is valuable in many benign diseases involving bone, particularly those which are more common in children and young adults, and in which early detection may be critical to future health. Bone scanning offers a simple yet reliable means for establishing an early diagnosis, evaluating the extent of the disease, and assessing the therapeutic response in disorders resulting from infection, trauma, or vascular insult. Useful information may also be obtained in disturbances of growth and development, and in congenital lesions.

  2. The toxicity of the bone seeking radionuclides

    International Nuclear Information System (INIS)

    Spiers, F.W.

    1989-01-01

    This editorial concludes that it is evident from work on radium dial painters at the Argonne National Laboratory and on beagles at the Universities of Utah and California that irradiation by α particles from 226 Ra and 239 Pu incorporated in bone results in tumours of bone but rarely if at all in tumours arising from bone marrow. The same can probably be said of α particle irradiation by other radionuclides deposited in bone or on bone surfaces. If α particles arise in bone or on bone surfaces, the trabecular marrow can be only partially irradiated with considerable fractions of marrow left intact. On the other hand it is evident from beagle data that when bone marrow is totally irradiated by the long range β particles from 90 Sr, whether fed orally or administered by single injection, both marrow neoplasms and bone tumours occur. Total irradiation of bone marrow by γ radiation, and some neutron radiation at Hiroshima and Nagasaki also resulted in leukaemia induction. (author)

  3. Radionuclide scanning after total knee replacement: correlation with pain and radiolucent lines. A prospective study

    DEFF Research Database (Denmark)

    Duus, B R; Boeckstyns, M; Kjaer, L

    1987-01-01

    The authors examined the relationships among Tc-99m radionuclide bone scan findings, pain, and radiolucent lines in 35 postsurgical knees. Our prospective study included bone scans, as well as radiographic and clinical examination three, seven, and 12 months after knee replacement surgery in 35...... and nonpainful knees, and the degree of isotope uptake did not correlate with the development of radiolucent lines around the prosthetic components....

  4. The role of bone scanning in neonatal rickets

    International Nuclear Information System (INIS)

    Saul, P.D.; Lloyd, D.J.; Smith, F.W.

    1983-01-01

    Preterm infants are at increased risk from rickets. Radionuclide bone scanning is a useful aid in suspected cases. It offers advantages over conventional radiology in terms of sensitivity, radiation dose and extent of examination. Unsuspected fractures of clinical or medicolegal significance may be detected. Two cases are described in which the technique confirmed the diagnosis and assisted management. (orig.)

  5. Radionuclide bone scintigraphy in pediatric orthopedics

    International Nuclear Information System (INIS)

    Conway, J.J.

    1986-01-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references

  6. Radionuclide bone scintigraphy in pediatric orthopedics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, J.J.

    1986-12-01

    Radionuclide bone scintigraphy is highly sensitive and specific for diagnosing the musculoskeletal disorders of childhood. Conditions such as neonatal osteomyelitis, septic arthritis, diskitis of childhood, Legg-Calve-Perthes disease, the osteochondroses, the toddler's fracture, sports injuries, spondylolysis, myositis ossificians, and reflex sympathetic dystrophy are readily defined. High-quality state-of-the-art scintigraphy is essential in infants and young children. 64 references.

  7. Bone scanning in the child and young adult. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Murray, I P.C. [Prince of Wales Hospital, Randwick (Australia). Dept. of Nuclear Medicine

    1980-02-01

    Radionuclide bone scanning will identify readily areas of the skeleton where vascularity or osteogenesis is disturbed. Frequently, this will be achieved with a greater sensitivity than orthodox radiology by reflecting altered local physiology of bone. This procedure is, therefore, valuable not only for identifying metastatic disease, but also in benign skeletal disorders characterised by altered blood flow or osteoblastic reaction. These changes occur in many diseases involving bone which are more common in children and young adults. Special attention to the performance of the study and to its interpretation is, however, required in these age groups. The bone scan is invaluable in detecting metastatic disease related to either primary bone tumours or other neoplasia, both in the initial investigation and in the evaluation of therapy. Extra-osseous uptake may also occur, providing useful information relevant to the care of these patients.

  8. The utility of bone scans in rheumatology

    International Nuclear Information System (INIS)

    Duncan, I.; Dorai-Raj, A.; Khoo, K.; Tymans, K.; Brook, A.

    1997-01-01

    Full text: Introduction: Bone scans are the commonest diagnostic imaging services requested by Australian rheumatologists. Medicare figures suggest that an average rheumatologist orders about $50 000 (AUS) of bone scans annually. Aims: To ascertain the reasons why rheumatologists request bone scans and how it affects their patient management. Methods: A two-part prospective survey was administered before and after every bone scan ordered by four rheumatologists over a six-month period in 1996. Results: A total of 136 bone scans were requested (66.2% whole body; 33.8% regional; 6% SPECT). The primary indications for scanning were (1) to confirm a clinical diagnosis (38%); (2) to exclude a diagnosis (34%); (3) to localize site of pain (17%); and (4) to assist in management (6%). The common diseases that rheumatologists were attempting to confirm/exclude with bone scanning were inflammatory arthritis, malignancy, and fracture. However, the commonest provisional and final diagnosis was soft tissue rheumatism (18%) followed by inflammatory arthritis (15%) and osteoarthritis (11%). In 24% of patients with a provisional diagnosis of soft tissue rheumatism the diagnosis was changed by the bone scan. The scan was successful in excluding a diagnosis in 88 per cent where this was the primary indication for the test. It was successful in confirming a diagnosis in 79 per cent where this was the primary indication. In 32 per cent the bone scan altered the clinical diagnosis and in 43 per cent it altered management. The bone scan result prevented further investigations in 60 per cent. Conclusions: The commonest pre-scan and post-scan diagnosis is soft tissue rheumatism. Rheumatologists predominantly request bone scanning to confirm or exclude their clinical suspicion of inflammatory arthritis, malignancy, and fracture. Bone scans were successful in achieving these objectives in at least 79 per cent of cases

  9. Experimental fracture healing: evaluation using radionuclide bone imaging: concise communication

    International Nuclear Information System (INIS)

    Gumerman, L.W.; Fogel, S.R.; Goodman, M.A.; Hanley, E.N. Jr.; Kappakas, G.S.; Rutkowski, R.; Levine, G.

    1978-01-01

    Radionuclide bone imaging was performed in a rabbit model to observe the course of fracture healing and to establish criteria for distinguishing nonunion and delayed healing from normal healing. Sequential gamma-camera images (with pinhole collimator) were collected and subjected to computer analysis. Five groups were established: (a) control--immobilization; (b) control--immobilization plus periosteal stripping; (c) simple fracture--osteotomy; (d) delayed union--osteotomy plus periosteal stripping; and (e) nonunion--osteotomy, periosteal stripping and polymethyl methacrylate interposed between fracture fragments. Histographic representation of absolute count rates along rabbit tibias followed a predictable pattern in the simple-fracture and delayed-union groups. They differed only in the time of appearance of phases. The non-union group demonstrated no recognizable sequential pattern. In this experimental model, serial bone scanning the quantitative data analysis has shown potential for indicating the course of healing in fractures and for serving as a guide to treatment

  10. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  11. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  12. The use of radionuclides in brain scan

    International Nuclear Information System (INIS)

    Boasquevisque, E.M.

    1979-01-01

    Brain scanning is easy to perform, safe and well tolerated by the patient. It has a high sensitivity, and accuracy (85-90%) in detecting focal lesions with a minimal size of 1.5-2cm, located superior to the brain stem; however, it lacks specificity. It does not compete with other procedures such as CT scan and angiography bit they rather complement one another. The brain scan is useful as a screening exam. (Author) [pt

  13. Quantification of radionuclide uptake levels for primary bone tumors

    Directory of Open Access Journals (Sweden)

    Hasford Francis

    2015-04-01

    Full Text Available The purpose of the study is to quantify the level of uptake of administered radionuclide in primary bone tumors for patients undergoing bone scintigraphy. Retrospective study on 48 patient's scintigrams to quantify the uptake levels of administered radiopharmaceuticals was performed in a nuclear medicine unit in Ghana. Patients were administered with activity ranging between 0.555 and 1.110 MBq (15–30 mCi, and scanned on Siemens e.cam SPECT system. Analyses on scintigrams were performed with Image J software by drawing regions of interest (ROIs over identified hot spots (pathologic sites. Nine skeletal parts namely cranium, neck, shoulder, sacrum, sternum, vertebra, femur, ribcage, and knee were considered in the study, which involved 96 identified primary tumors. Radionuclide uptakes were quantified in terms of the estimated counts of activity per patient for identified tumor sites. Average normalized counts of activity (nGMC per patient ranged from 5.2759 ± 0.6590 cts/mm2/MBq in the case of cranium tumors to 72.7569 ± 17.8786 cts/mm2/MBq in the case of ribcage tumors. The differences in uptake levels could be attributed to different mechanisms of Tc-99m MDP uptake in different types of bones, which is directly related to blood flow and degree of osteoblastic activity. The overall normalized count of activity for the 96 identified tumors was estimated to be 23.0350 ± 19.5424 cts/mm2/MBq. The study revealed highest uptake of activity in ribcage and least uptake in cranium. Quantification of radionuclide uptakes in tumors is important and recommended in assessing patient's response to therapy, doses to critical organs and in diagnosing tumors.

  14. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Levin, W.J.; Shary, J.H. III; Nichols, L.T.; Lucente, F.E.

    1986-01-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  15. Bone scan in diagnosis of infectious osteoarthritis

    International Nuclear Information System (INIS)

    Marandian, M.H.; Mortazavi, H.; Behvad, A.; Haghigat, H.; Lessani, M.; Youssefian, B.

    1979-01-01

    Bone scan with Technetium 99m is harmless method of evaluation of skeletal lesions. It is safe in pediatrics age group and it can be used in early diagnosis of infectious osteoarthritis. Bone scan differentiate osteomyelitis from cellulitis, and also it may help in diagnosis of subclinical involvement of rheumatoid arthritis, benign and malignant bone tumors, stress fractures and periostitis. We report results of bone scan in 30 pediatrics patients as follow: osteomyelitis 9 cases, cellulitis 4 cases, infectious arthritis 7 cases, tuberculous osteoarthritis 2 cases, rheumatoid arthritis 2 cases, and other different diseases 9 cases [fr

  16. Role of bone scanning in osteomalacia

    International Nuclear Information System (INIS)

    Fogelman, I.; McKillop, J.H.; Bessent, R.G.; Boyle, I.T.; Turner, J.G.; Greig, W.R.

    1978-01-01

    The presence of eight ''metabolic features'' was assessed on the bone scintigrams of ten patients with osteomalacia. In all of these bone images, sufficient features were present to strongly suggest a metabolic disorder. These scintiphotos were included in a controlled blind study using 30 normal bone scans and 20 scans of metastatic disease. Nine of the ten metabolic bone images were correctly identified by two independent observers. Skeletal uptake of radiotracer, expressed as bone-to-soft-tissue ratio, was significantly higher in the osteomalacic patients than in a group of 80 controls

  17. Gout: Value of bone scanning

    International Nuclear Information System (INIS)

    Oliva, J.P.; Cardenas, R.; Bell, L.; Gonzalez Griego, J.

    1986-01-01

    11 male patients with gout were studied by means of bone scintigraphy with 99m TcMDP. This diagnostic method rendered possible the diagnosis of clinically or roentgenologically occult bone involvement. Bone scintigraphy may be useful procedure to monitor therapy of gout. (orig.) [de

  18. “Pseudo-thyroid lobe”: A diagnostic conundrum caused by ossified anterior longitudinal ligament on bone scan

    International Nuclear Information System (INIS)

    Zaman, Maseeh Uz; Fatima, Nosheen; Sajjad, Zafar; Zaman, Unaiza; Zaman, Areeba; Tahseen, Rabia

    2015-01-01

    Radionuclide bone imaging is one of the most commonly performed nuclear medicine procedure around the world and characterized by its high sensitivity and relatively low specificity. False positive findings on a bone scan are very common; however, dense uptake over unilateral ossified anterior longitudinal ligament appearing as single thyroid lobe on a bone scan has not been described in the literature

  19. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    International Nuclear Information System (INIS)

    Buckland-Wright, J.C.; Lynch, J.A.; Macfarlane, D.G.; Homoeopathic Hospital, Tunbridge; Fogelman, I.; Emery, P.

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.)

  20. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    Energy Technology Data Exchange (ETDEWEB)

    Buckland-Wright, J.C.; Lynch, J.A. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy); Macfarlane, D.G. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy Homoeopathic Hospital, Tunbridge (UK). Dept. of Rheumatology); Fogelman, I. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Nuclear Medicine); Emery, P. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Rheumatology)

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.).

  1. Role of bone scan in rheumatic disease

    International Nuclear Information System (INIS)

    Choi, Yun Young

    2003-01-01

    Rheumatic diseases can be categorized by pathology into several specific types of musculoskeletal problems, including synovitis (e.g. rheumatoid arthritis), enthesopathy (e.g. ankylosing spondylitis) and cartilage degeneration (e.g. osteoarthritis). Skeletal radiographs have contributed to the diagnosis of these articular diseases, and some disease entities need typical radiographic changes as a factor of the diagnostic criteria. However, they sometimes show normal radiographic findings in the early stage of disease, when there is demineralization of less than 30-50%. Bone scans have also been used in arthritis, but not widely because the findings are nonspecific and it is thought that bone scans do not add significant information to routine radiography. Bone scans do however play a different role than simple radiography, and it is a complementary imaging method in the course of management of arthritis. The image quality of bone scans can be improved by obtaining regional views and images under al pin-hole collimator, and through a variety of scintigraphic techniques including the three phase bone scan and bone SPECT. Therefore, bone scans could improve the diagnostic value, and answer multiple clinical questions, based on the pathophysiology of various forms of arthritis

  2. Bone scans in nasopharyngeal carcinoma: local experience

    International Nuclear Information System (INIS)

    Tiong, S.

    2004-01-01

    Introduction: Nasopharyngeal carcinoma (NPC) tops the list of malignancy in Malaysia and ranks first in male malignancy in the state of Sarawak. The majority of the NPC patients presented in the advanced stages and often with distal metastasis usually to the bones. In our local hospital is the new practice of bone scan using Tc99 started last year. Over a period of 9 months from July 2003 to March 2004, 41 NPC patients had the bone scans and our experience in these are reviewed and presented. Method: The NPC patients are selected consecutively including both new and treated patients. The scanner used is Siemen E.cam plus and Technecium (Tc99) the radio-active isotope used. The scan images are read and reported by qualified and trained Radiologists. The bone scans are requested from the ENT Specialist of the ENT department of the Hospital. The bone scan reports are checked by the ENT Specialists and the decisions made as to clinical correlation and further definitive imaging studies. Results: 41 NPC patients were included in the studies, 29 newly diagnosed and bone-canned before treatment started and 12 treated of which 3 being diagnosed having recurrent NPC. Of the 29 newly diagnosed patients, one was found true positive bone scan having increased radio-tracer uptake and confirmed Xray imagings. 3 of the treated patients had true positive bone scan with increased radio-tracer uptake and confirmed Xray imagings. Hence a total of 4 out of the 41 patients (9.8%) had bone metastasis on positive bone scans. Of the 29 newly diagnosed patients, 14 were found false positive bone scan having increased radio-tracer uptake but no confirmed X ray imagings. 4 of the treated patients had false positive bone scan with increased radio-tracer uptake but no confirmed X ray imagings. Hence a total of 18 out of the 41 patients (44%) had no bone metastasis on positive bone scans. There were 6 patients with symptoms referable to the bones' distal to the head and 2 had true positive bone

  3. Reappraisal of radionuclide liver scans for preoperative gastric cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Makoto; Yonahara, Yoshio; Yamashita, Shoji; Ando, Yutaka; Mohri, Makoto [National Second Hospital of Tokyo (Japan)

    1983-04-01

    Radionuclide liver scans were obtained in 89 preoperative patients with gastric cancer. Eight showed definite defects on liver scans. At laparotomy, 14 patients were found to have liver involvement secondary to gastric cancer. The sensitivity of liver scans to predict liver involvement is 57% (8/14), and the specificity is 100% (75/75). The patients with definite defects on liver scans had a lower rate of palliative resection of the primary tumors (2/8) than the patients with liver involvement and no scan abnormality (4/6). The patients with advanced lesions but without liver involvement had the highest probability of resecting the primary tumors (57/63 : 47 radical, and 10 palliative). Normal serum levels of liver chemistries did not preclude the presence of defects on liver scans. Additional three patients were found to have cirrhosis of the liver solely based on liver scans, which was confirmed at laparotomy. Radionuclide liver scans can predict liver involvement with very few false positives, and may discriminate patients unsuitable for laparotomy even with palliative intent.

  4. Technical errors in planar bone scanning.

    Science.gov (United States)

    Naddaf, Sleiman Y; Collier, B David; Elgazzar, Abdelhamid H; Khalil, Magdy M

    2004-09-01

    Optimal technique for planar bone scanning improves image quality, which in turn improves diagnostic efficacy. Because planar bone scanning is one of the most frequently performed nuclear medicine examinations, maintaining high standards for this examination is a daily concern for most nuclear medicine departments. Although some problems such as patient motion are frequently encountered, the degraded images produced by many other deviations from optimal technique are rarely seen in clinical practice and therefore may be difficult to recognize. The objectives of this article are to list optimal techniques for 3-phase and whole-body bone scanning, to describe and illustrate a selection of deviations from these optimal techniques for planar bone scanning, and to explain how to minimize or avoid such technical errors.

  5. Thalassemia paravertebral tumors and bone marrow scan

    International Nuclear Information System (INIS)

    Huglo, D.; Rose, C.; Deveaux, M.; Bauters, F.; Marchandise, X.

    1995-01-01

    Two first cousins with thalassemia and with a paravertebral mass had had an indium 111 chloride bone marrow scan. Result of scan influenced therapy: medical treatment in one case where an extramedullary erythropoiesis was confirmed, surgical treatment in the other case. The use of dual-isotope SPECT (indium 111 chloride, HDP -99 Tc) constitutes a contribution to the establishment of diagnosis of extramedullary erythropoiesis, giving to bone marrow scintigraphy a merited importance, avoiding the biopsy. (authors). 15 refs., 5 figs

  6. What expects orthopedic surgeon from bone scan?

    International Nuclear Information System (INIS)

    Sutter, B.; Cazenave, A.

    2003-01-01

    The isotope bone scan continues to be one of the 'lost widely performed nuclear medicine investigations. Beyond the common clinical indication like detection of skeletal metastases, bone scan use is increasing in benign orthopedic conditions, and after orthopedic surgery, despite development of new investigations modalities (US, MRI). Three (or two) phase bone scintigraphy, Single Photon Emission Computer Tomography have increased its value and provided new clinical roles. This review emphasizes through some practical clinical examples how to increase diagnostic value of the method and to offer an adapted response to the orthopedic surgeon's attempts. (author)

  7. New aspects of radionuclide therapy of bone and joint diseases

    International Nuclear Information System (INIS)

    Fischer, M.

    2001-01-01

    Whereas in developing countries P-32 is widely used for radionuclide therapy of painful bone metastases, in Europe three radionuclides or radiopharmaceutical agents are available for pain palliation: Sr-89, Sm-153-EDTMP, and Re-186-HEDP. Radionuclide therapy for pain palliation is indicated for bone pain due to metastatic malignancy that has involved multiple skeletal sites and has evoked an osteoblastic response on bone scintigraphy. Response rates of about 70-80% in patients with breast or prostate cancer is reported in the literature, less in metastatic lesions of other primary malignancies. Sm-153-EDTMP may also be used for curative treatment of primary bone tumours or their metastases. Radiosynovectomy as therapeutic procedure or rheumatoid arthritis, other inflammatory joint diseases, persistent synovial perfusion, and other joint diseases is widely used. Using Y-90 for the knee joint, Re-186 for middle sized joints, and Er-169 for small joints an improvement of symptoms may be observed in about 70-80%. (author)

  8. Cells at risk from bone-seeking radionuclides: a review

    International Nuclear Information System (INIS)

    Hashimoto, E.G.; Jee, W.S.S.

    1976-01-01

    Although it is possible that any cell within range of an α-emitting radionuclide ( 239 Pu and 226 Ra) residing at a bone surface might be transformed into a bone forming neoplastic cell, the three most likely candidates are the the osteoprogenitor cell, the osteoblast, and the reticular cell of the marrow. These cells all possess osteogenic capability, proliferative activity, and resemblance to bone tumor cells

  9. Isotope bone scanning in operable mammary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Maylin, C [Centre Hospitalier Universitaire, 94 - Creteil (France); Vilcoq, J R; Schlienger, P; Calle, R [Institut du Radium, 75 - Paris (France)

    1977-01-01

    In the pre-treatment work-up in breast carcinoma cases, the bone scan findings could be of major interest. If the presence of occult metastases is discovered management may be modified accordingly. In a group involving 78 cases of breast carcinoma, classified as primary, operable, in three cases only scintigraphy revealed bone metastases before they produced clinical and radiological signs. In two of them there was agreement, in one disagreement over the findings. Moreover, in 5 cases a bone metastasis was revealed and immediately confirmed on a complete bone assessment.

  10. Bone scanning in the evaluation of lung cancer

    International Nuclear Information System (INIS)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk

    1994-01-01

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%

  11. Bone scanning in the evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-05-15

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%.

  12. Clinical research of bone scan characteristics for metabolic bone diseases

    International Nuclear Information System (INIS)

    Zhu Ruisen; Luo Qiong; Lu Haikui; Chen Libo; Luo Quanyong

    2009-01-01

    Characteristic images of 99m Tc-MDP bone scintigraphy in patients with metabolic bone diseases (MBD) were analyzed and compared, in an attempt to improve the capability of differential diagnosis in this aspect. A total of 142 cases, clinically confirmed as (MBD), were categorized into six groups: hyperparathyroidism (117), renal osteodystrophy (4), Paget's disease (16), hypophosphatemic osteomalacia (2), Albers-Schonberg disease (2), and Brittle bone disease (1). They were diagnosed clinically or pathologically, and scanned with 99m Tc-MDP bone scintegraphy, from which the 142 MBD cases were classified into 4 types. The cases of Type I had increased amount of 99m Tc-MDP uptake in whole body bones, including hyperparathyroidism, Albers-Schonberg disease, brittle bone disease and renal osteodystrophy. The cases of Type II had high uptake of 99m Tc-MDP in local region of bones, including paget's disease, hypophosphatemic osteomalacia and hyperparathyroidism. A Type I case with pathological fracture or secondary osteopathy was classified as Type III. Type IV cases were in early stage of hyperparathyroidism, with normal bone scan image. Analysis of the characteristics of 99m Tc-MDP bone scintigraphic findings (locations, morphology and intensities) in patients with MBD may be helpful in the differential diagnosis of MBD, in association with the patient's history and X-ray data altogether. (authors)

  13. Bone scan in mastocytosis: case report

    International Nuclear Information System (INIS)

    Sy, W.M.; Bonventre, M.V.; Camera, A.

    1976-01-01

    A 45-year-old man with well-documented systemic mastocytosis showed generalized symmetric increased activity on bone imaging. These scan findings are grossly indistinguishable from those of patients with renal osteodystrophy or secondary hyperparathyroidism. The images of the hands, however, failed to show the changes observed in secondary hyperparathyroidism. The mechanism for this intense activity is thought to be due to aberrant new-bone formation

  14. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  15. Three phase bone scan in sports injuries

    International Nuclear Information System (INIS)

    Chauhan, M.S.; Chowhan, M.

    2007-01-01

    Full text: Sports injuries are common in individual who participate in sports and exercise related activities. In majority of sports related injuries such as stress fracture, periosteitits, acute stress reaction of bone, the radiological investigations are usually normal in early stages. These injuries can lead to serious complications if not detected early and managed properly. This study was jointly carried out in premier medical institutes. All patients were referred from premier sports institute of the country and also by orthopedic surgeons. All patients were subjected for relevant radiological investigations and 3 phase bone scan. Total number of cases included in this study was 70 (N=70) among which bone scan was positive for stress fracture in 45 patients and shin splint was detected in 15 patients and avulsion injury seen in 3 patients. However, only one patient showed features of avulsion injury in X ray and in 1 patient X-ray was inconclusive. Conclusion:-The study shows that 3 phase bone scan is the most sensitive and relatively an inexpensive study. Bone scan has the ability for early detection of sports injuries and provide physiological information and evaluate multiple sites in single examination.SPECT study will help in the diagnostic specificity. (author)

  16. Radionuclide bone imaging in suspected skeletal metastasis: does it contribute to diagnosis or treatment ?

    International Nuclear Information System (INIS)

    Reddy, K.G.; Subbarao, K.; Kumaresan, K.; Murthy, V.S.; Kishore, L.T.

    1988-01-01

    A retrospective analysis of 47 patients with suspected bone metastases is performed to evaluate the role of bone scan in diagnosis or treatment and to compare radionuclide images with radiographs. Scan revealed solitary lesions in 27.7 per cent, multiple lesions in 44.7 per cent and was normal in 10.6 per cent of patients studied. In 11 patients the scan was +ve and x-ray was -ve and scan was false negative in one patient. Role of bone scan is evaluated by a scoring method. Scan contributed to correct diagnosis in 25.5 per cent, altered the management in 21.3 per cent of patients. However, scan by itself did not contribute to final management in 48.6 per cent of patients. Scan had misled the diagnosis because of false positive result in 4.3 per cent of patients. It is highlighted that though bone scan is non-specific, it has contributed considerably to the management of majority of patients. (author). 10 refs., 3 tabs., 4 figs

  17. Bone scanning in Shin Splint evaluation

    International Nuclear Information System (INIS)

    Dumont, M.; Lamoureux, F.; Lamoureux, J.; Danais, S.; Lacoste, P.; Duranceau, J.

    1983-01-01

    Jogging is increasingly popular; in U.S.A., in 1979 more than 25 millions people were considered joggers. Lesions of the locomotive system of the lower limbs are very frequent in athletes and the Shin Splint syndrome, for one, is very frequent. However this precise clinical entity, usually X-Ray negative, is ill-known. A bone scan study in a series of 30 athletes suffering from Shin Splints is presented. The bone scans being positive and typical were highly useful in confirming the clinical diagnosis. Moreover, follow-up studies were done in a number of these patients and results correlated well with the clinical evolution [fr

  18. Recent developments in bone scanning

    International Nuclear Information System (INIS)

    Ell, P.J.; Radia, R.G.; Jarritt, P.H.

    1981-01-01

    Progress in nuclear medicine is achieved through advances in radiopharmaceuticals, improvement in instrumentation design and improvement in data processing (computer hard- and software). With the appearance of the sup(99m)Tc-labelled phosphates, a major step towards finding ideal bone seeking tracers was undertaken. The more recent modifications of these tracers have tended to offer only minor advantages over and above what has already been achieved, i.e., improved skeletal uptake and somewhat faster blood clearance characteristics. Whilst computer hard- and software is undergoing constant streamlining (more power, in lesser space, with greater economy), instrumentation designs have matured. All of these techniques have relied upon conventional planar imaging and only very recently have alternative apparatuses appeared. The issue at stake is whether some form of tomographic imaging may have a role to play in the investigation of the skeleton. Important and inherent advantages occur if one is able to reconstruct data into tomograms: data interpretation is performed with the benefit of depth information, contrast resolution permits the visualization of structures previously masked and computer analysis permits the measurement of tracer uptake within well-defined sections of the organ or segment to be investigated. In this review, the authors offer original data which may provide some pointers as to future areas of application of this new approach. (Auth.)

  19. Myositis ossificans and the three-phase bone scan

    International Nuclear Information System (INIS)

    Drane, W.E.

    1984-01-01

    Myositis ossificans circumscripta (or paraosteoarthropathy) in paraplegics has been a well known entity since its classic description in 1918 by Dejerine and Ceillier. The disease is characterized by ectopic bone formation, primarily occurring in the particular soft tissues of the hips and knees. Hypotheses concerning its origin have been proposed, but its etiology is still unknown. Myositis ossificans can occur after traumatic injury, but develops in paraplegics without apparent injury in the involved regions. Radionuclide techniques have been used in the evaluation of myositis ossificans, particularly with serial studies to stage the activity of the disease. The author reports a case of myositis ossificans in a paraplegic that emphasizes the benefit of the three-phase bone scan in the early diagnosis of this disorder

  20. Investigations of Differential Scanning Techniques using Two Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Cottrall, M. F.; French, Rosemary J.; Trott, N. G. [Institute of Cancer Research and Royal Marsden Hospital, Sutton, Surrey (United Kingdom)

    1969-01-15

    In the development of scanning procedures difficulties sometimes arise because a particular radiopharmaceutical, which is selectively concentrated in an organ of interest, is also widely distributed in neighbouring sites in the body. Investigations have been made of a method which involves the use of a second radioactive substance to label such sites. By means of suitable electrical circuits fitted to a conventional mechanical scanner (Picker Magnascanner III), a direct colour scan of the organ under study can be obtained. Signals from the two radionuclides are distinguished by pulse-height analysis and used to operate the colour shift mechanism. Experimental studies with phantoms and clinical trials are reported. An analysis of the statistical limitations of the technique is given, including a discussion of the most suitable operating conditions for particular pairs of radionuclides. Illustrations include the use of {sup 75}Se selenomethionine and {sup 99m}Tc sulphur colloid or {sup 198}Au colloid in the delineation of the pancreas, and reference is also made to work with {sup 18}F, {sup 99m}Tc, {sup 133m}In and {sup 197}Hg, which are used in various chemical forms to visualize specific types of tumours in vascular surroundings labelled with other suitable tracers. Some discussion of the dosimetry of these procedures is made, since the extent to which the technique can be applied may be limited by the activities which can be administered. However, successful results are being obtained using activities within the range generally accepted for single radionuclide scanning procedures. For example, the pancreas can be successfully visualised using 250 {mu}Ci {sup 75}Se selenomethionine in combination with 1 mCi {sup 99m}TC sulphur colloid. (author)

  1. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  2. Bone mineral density scans in veterans

    Directory of Open Access Journals (Sweden)

    Elizabeth Bass

    2007-07-01

    Full Text Available Elizabeth Bass1,2, Etienne Pracht1,3, Philip Foulis4,51VISN 8 Patient Safety Center of Inquiry, Tampa, FL; 2School of Aging Studies, University of South Florida, Tampa, FL, USA; 3College of Public Health, University of South Florida, Tampa, FL, USA; 4James A Haley VA Hospital, Tampa, FL, USA; 5Pathology and Laboratory Medicine, College of Medicine, University of South Florida, Tampa, FL, USAGoals: Recent findings suggest the prevalence of osteoporosis among men is under-recognized. The patient population of the Veterans Health Administration (VA is predominantly male and many elderly veterans may be at risk of osteoporosis. Given the lack of data on male osteoporosis, we provide initial insight into diagnostic procedures for patients at one VA medical center. Procedures: A review and descriptive analysis of patients undergoing radiological evaluation for osteoporosis at one VA medical center.Results: We identified 4,919 patients who had bone mineral density scans from 2001–2004. VA patients receiving bone mineral density scans were commonly white, male, over age 70 and taking medications with potential bone-loss side effects.Conclusions: While further research is needed, preliminary evidence suggests that the VA screens the most vulnerable age groups in both genders. Heightened awareness among primary care providers of elderly male patients at risk of osteoporosis can lead to early intervention and improved management of this age-related condition.Keywords: bone mineral density scans, osteoporosis, veterans

  3. Radionuclide imaging of bone marrow in hematologic systemic disease

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, F.; Hahn, K.; Gamm, H.

    1987-02-01

    Radionuclide imaging studies of the bone marrow were carried out in 164 patients suffering from hematologic systemic disease. One third of 90 patients with Hodgkin lymphoma (HL) or Non Hodgkin lymphoma (NHL) displayed a pathological distribution pattern representing bone marrow expansion. In HL there were 17% accumulation defects caused by metastases in contrast to only 7% in NHL. Among 30 patients with chronic myelocytic leukemia bone marrow expansion was found in 60%, bone marrow displacement and aplasia 10%. Focal bone marrow defects were found in 3 patients. All patients with primary polycythemia rubra vera displayed a pathologic bone marrow distribution pattern as well as splenomegaly. All patients with acute myelocytic leukemia (AML) and one patient with an acute lymphatic leukemia (ALL) had a pathological distribution pattern with bone marrow expansion and displacement. Focal bone marrow defects were not seen. Multiple myeloma with bone marrow expansion was found in 6 of 12 patients and focal accumulation defects were found in 40%, the latter lesions being not visible or equivocal on skeletal imaging studies. Pathological changes in liver and spleen were found in a high percentage of the total collective. The results document the important clinical value of bone marrow scintigraphy among the hematologic diseases studied.

  4. Multiple Bony Injuries on Bone Scan in a Case of Unsuspected Child Abuse

    Directory of Open Access Journals (Sweden)

    Ya-Wen Chuang

    2017-01-01

    Full Text Available This case is described of an eleven-month-old infant with lower limbs swelling and the left elbow skeletal malformation following a fall. The radionuclide bone scan was performed to exclude bone infection or congenital skeletal anomaly. The images unexpectedly showed multiple increased radioactive foci throughout the whole body. It was a strong probability of child abuse. All lesions are readily apparent on the following plain film radiographs and MRI.

  5. Scanning electron microscopy of primary bone tumors

    International Nuclear Information System (INIS)

    Pool, R.R.; Kerner, B.

    1975-01-01

    Critical-point-drying of tumor tissue fixed in a glutaraldehyde-paraformaldehyde solution and viewed by scanning electron microscopy (SEM) provides a 3-dimensional view of tumor cells and their matrices. This report describes the SEM appearance of three primary bone tumors: a canine osteosarcoma of the distal radius, a feline chondrosarcoma of the proximal tibia and a canine fibrosarcoma of the proximal humerus. The ultrastructural morphology is compared with the histologic appearance of each tumor

  6. Early detection of Freiberg's disease by radionuclide bone imaging

    International Nuclear Information System (INIS)

    Peng Jingjing

    1993-01-01

    56 hallux valgus deformities of 28 patients were studied with radionuclide bone imaging (RNBI). Among them, 24 feet(42.85%) revealed increased uptake of radioactivity in second or third metatarsal. The ratio of radioactivity in lesion and contralateral normal site (D/N) was increased, the difference between the patient and normal groups was significant (P<0.01). The histologic study showed that there have been degenerative changes and bone cell necrosis in increased uptake area. It was concluded that RNBI was more sensitive than X ray and can be used for the early diagnosis of Freiberg's Disease

  7. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  8. Bone scan and red blood cell scan in a patient with epidermal naevus syndrome

    International Nuclear Information System (INIS)

    Becker, W.; Wolf, F.; Stosiek, N.; Peters, K.P.

    1990-01-01

    A bone scan and red blood cell scan in the rare epidermal naevus syndrome, associated with multiple haemangiomes of the bone and hypophosphataemic osteomalacia in a 20-year-old man are reported. The typical pattern of osteomalacia on the bone scan was associated with lesions of increased bone metabolism in the peripheral bones. The haemangiomas did not pool labelled red blood cells. Thus, the bone scan seems to be suited for diagnosing the complete extent of haemangiomas in bone, but they could not be specifically proven by red blood cell pooling. (orig.)

  9. Where is the place of bone scan in breast cancer?

    International Nuclear Information System (INIS)

    Nowferesti, G. H.; Ghavam Nasiri, M. R.; Anvari, K.

    2002-01-01

    Breast cancer is the most common female cancer in west and in Iran. The incidence in all over the world in year 2000 was 1050000 cases out of which 370000 were dead. General y bone is the most common site of distant. Metastases in beast cancer. Bone scan has an important place in the bone metastases and extent of bone disease and even in the staging and treatment protocol. In study done during 1 year, breast cancer patients and place of bone scan were studied. Every year more than 2000 new patients with cancer are diagnosed and treated in Khorasan state. And more than half of them are treated in Omid Hospital. In the year 2000 a study was done. 1336 new cases were admitted for treatment out of which 164 persons (13%) were breast cancer patients. 100 patients were selected randomly and different factors were studied. How many patients had bone scan and its place in breast cancer? Where is the most common metastatic place and relation with bone scan? The differential diagnosis in positive bone scans and comparing with radiography and patient's clinic were studied. Bone scan is positive in 35% of patients in stage III. Bone is the most common place for distant metastases in breast cancer in patients admitted in Omid hospital in year 2000. Clinical and para clinical study such as radiography and tumour markers were adjusted with bone scan, more in stages III and IV. 39 patients out of 100 studied patients had bone scan. 28 bone scan were adjusted radiologically. In 20 positive bone scan out of 28 patients with metastases 12 patients had bone metastases. Despite 5% positive bone scan in early stages can suggest that bone scan be taken for all patients with breast cancer as a basic step?

  10. Super bone scans on bone scintigraphy in patients with metastatic bone tumor

    International Nuclear Information System (INIS)

    Morita, Koichi; Fukunaga, Masao; Otsuka, Nobuaki

    1988-01-01

    Eight patients with malignant tumor (3 with gastric cancer, 4 with prostatic cancer, 1 with transitional cell carcinoma), which showed diffusely increased uptake of 99m Tc labelled phosphorous compound in axial skeleton (''Super Bone Scan'') on bone scintigraphy were clinically studied. No relationship with its histological type of the tumor was recognized. All cases revealed extremely high serum ALP concentration, which might reflect increased osteoblastic activity. Furthermore, on bone roentgenograms all cases showed predominantly osteosclerotic change in the metastatic bones, while some did locally osteolytic change. In three cases with gastric cancer, although they had diffuse skeletal metastases, two had no evidence of liver metastases. Thus, it seemed that clinical study of patients with ''Super Bone Scan'' was interesting to evaluate the mechanism of accumulation of 99m Tc labelled phosphorous compound to bone and bone metabolism, and the pathophysiology in the pathway of bone metastases. (author)

  11. Quantitative bone scanning after asymptomatic Charnley arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Mullaji, A.B. (University Department of Orthopedic and Accident Surgery, Royal Liverpool University Hospital, Lierpool (United Kingdom)); Tood, R.C. (Department of Orthopedics, Black Notley Hospital, Braintree (United Kingdom)); Robinson, S. (Department of MedicaL Physics, Colchester General Hospital, Colchester (United Kingdom)); Critchley, M. (Department of Nuclear Medicine, Royal Liverpool University Hospital, Liverpool (United Kingdom))

    1994-06-01

    To establish the normal pattern of postoperative tracer uptake we performed 73 [sup 99m]technetium methylene disphosphonate scans following primary Charnley hip replacements for arthrosis in 68 patients without clinical, hematological and radiographic complications. The patients were divided into 7 subgroups according to the period, 6-24 months, between surgery and scan. There were 10-12 patients in each subgroup. A high-resolution gamma camera with a large filed of view was used. Ratios of uptake in each of 10 peri-prosthetic zones to normal bone were calculated. Femoral uptake was found to decrease in linear fashion from 6 to 12 months after surgery. Thereafter the uptake remained unaltered at levels nearly twice the normal ones in the greater trochanter and nearly 1.5 times in the lesser trochanter, returning to almost normal levels in other zones. Acetabular uptake remained elevated throughout. (au) (20 refs.).

  12. Quantitative bone scanning after asymptomatic Charnley arthroplasty

    International Nuclear Information System (INIS)

    Mullaji, A.B.; Tood, R.C.; Robinson, S.; Critchley, M.

    1994-01-01

    To establish the normal pattern of postoperative tracer uptake we performed 73 99m technetium methylene disphosphonate scans following primary Charnley hip replacements for arthrosis in 68 patients without clinical, hematological and radiographic complications. The patients were divided into 7 subgroups according to the period, 6-24 months, between surgery and scan. There were 10-12 patients in each subgroup. A high-resolution gamma camera with a large filed of view was used. Ratios of uptake in each of 10 peri-prosthetic zones to normal bone were calculated. Femoral uptake was found to decrease in linear fashion from 6 to 12 months after surgery. Thereafter the uptake remained unaltered at levels nearly twice the normal ones in the greater trochanter and nearly 1.5 times in the lesser trochanter, returning to almost normal levels in other zones. Acetabular uptake remained elevated throughout. (au) (20 refs.)

  13. Three-phase radionuclide bone imaging in sports medicine

    International Nuclear Information System (INIS)

    Rupani, H.D.; Holder, L.E.; Espinola, D.A.; Engin, S.I.

    1985-01-01

    Three-phase radionuclide bone (TPB) imaging was performed on 238 patients with sports-related injuries. A wide variety of lesions was encountered, but the most frequent lesions seen were stress fractures of the lower part of the leg at the junction of the middle and distal thirds of the posterior tibial cortex (42 of 79 lesions). There were no differences in the type, location, or distribution of lesions between males and females or between competitive and noncompetitive athletes. In 110 cases, bone stress lesions were often diagnosed when radiographs were normal, whereas subacute or chronic soft-tissue abnormalities had few specific scintigraphic features. TPB imaging provides significant early diagnostic information about bone stress lesions. Normal examination results (53 cases) exclude underlying osseous pathologic conditions

  14. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  15. Using radionuclide imaging for monitoring repairment of bone defect with tissue-engineered bone graft in rabbits

    International Nuclear Information System (INIS)

    Xia Changsuo; Ye Fagang; Zou Yunwen; Ji Shixiang; Wang Dengchun

    2004-01-01

    Objective: To observe the effect of tissue-engineered bone grafts in repairing bone defect in rabbits, and assess the value of radionuclide for monitoring the therapeutic effect of this approach. Methods: Bilateral radial defects of 15 mm in length in 24 rabbits were made. The tissue-engineered bone grafts (composite graft) contained bone marrow stromal cells (BMSCs) of rabbits and calcium phosphate cement (CPC) were grafted in left side defects, CPC only grafts (artificial bone graft) in right defects. After the operation, radionuclide was used to monitor the therapeutic effects at 4, 8 and 12 weeks. Results: 99 Tc m -methylene diphosphonic acid (MDP) radionuclide bone imaging indicated that there was more radionuclide accumulation in grafting region of composite than that of CPC. There was significant difference between 99 Tc m -MDP uptake of the region of interest (ROI) and scintillant counts of composite bone and the artificial bone (P<0.01). Conclusion: Tissue-engineered bone grafts is eligible for repairing radial bone defects, and radionuclide imaging may accurately monitor the revascularization and bone regeneration after the bone graft implantation. (authors)

  16. Scanning electron microscopic studies on bone tumors

    International Nuclear Information System (INIS)

    Itoh, Motoya

    1978-01-01

    Surface morphological observations of benign and malinant bone tumors were made by the use of scanning electron microscopy. Tumor materials were obtained directly from patients of osteogenic sarcomas, chondrosarcomas, enchondromas, giant cell tumors and Paget's sarcoma. To compare with these human tumors, the following experimental materials were also observed: P 32 -induced rat osteogenic sarcomas with their pulmonary metastatic lesions, Sr 89 -induced transplantable mouse osteogenic sarcomas and osteoid tissues arising after artificial fractures in mice. One of the most outstanding findings was a lot of granular substances seen on cell surfaces and their intercellular spaces in osteoid or chondroid forming tissues. These substances were considered to do some parts in collaborating extracellular matrix formation. Protrusions on cell surface, such as mucrovilli were more or less fashioned by these granular substances. Additional experiments revealed these substances to be soluble in sodium cloride solution. Benign osteoid forming cells, such as osteoblasts and osteoblastic osteosarcoma cells had granular substances on their surfaces and their intercellular spaces. On the other hand, undifferentiated transplantable osteosarcoma which formed on osteoid or chondroid matrix had none of these granular substances. Consequently, the difference of surface morphology between osteosarcoma cells and osteoblasts was yet to be especially concluded. (author)

  17. Module for applications of bone scan in cancer patients

    International Nuclear Information System (INIS)

    Morales, Rosanna; Cano, Roque; Velasquez, Maria; Vasquez, Edinson; Diaz, Pepe; Vasquez, Mario; Rojas, Peter

    2013-01-01

    This paper reports the application of a software which enables the complete register of patient data, for delivering appropriate information in bone scan reports. Bone scan is a frequent study in Nuclear Medicine, which enables physicians to diagnose a primary bone cancer or metastases. The software was designed in order to complete data given by oncologists and constitutes an aid for the health team attending patients. (authors).

  18. Bone scintigraphy and osteo-articular tuberculosis in transplant patients: a study of 50 bone scans

    International Nuclear Information System (INIS)

    Coulaud, J.P.; Mechali, D.; Morau, G.

    1982-01-01

    Bone scintigraphy with 99 m technecium labelled phosphorus compounds was achieved in 50 west Africans migrant workers in Paris. Bone and joint tuberculosis was assumed in 20 cases. In 5 of these 20 cases, bone scan, but not X-ray, showed abnormalities, and in 4, bone scan disclosed more localisations than X-rays. In 7 cases, yet, bone scan was normal, with major osteolytic X-rays lesions in 3 cases, minor in 2 cases, and isolated cold abcesses in two more cases: these means 7 false-negative results. Among the 30 other cases, 29 were considered as mechanical vertebral pathology, and 1 sacro-iliitis Brucellosis. Bone scan was normal in 28 cases the 2 others are unexplained false-positive. Although non-specific and not completely reliable, we think that bone-scanning is useful in bone-tuberculosis check-up, especially to obtain early diagnosis and detect multifocal localisations [fr

  19. Bone scintigraphy and osteo-articular tuberculosis in transplant patients: a study of 50 bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Coulaud, J.P.; Mechali, D.; Morau, G. (Hopital Claude-Bernard, Paris (France))

    1982-01-01

    Bone scintigraphy with 99 m technecium labelled phosphorus compounds was achieved in 50 west Africans migrant workers in Paris. Bone and joint tuberculosis was assumed in 20 cases. In 5 of these 20 cases, bone scan, but not X-ray, showed abnormalities, and in 4, bone scan disclosed more localisations than X-rays. In 7 cases, yet, bone scan was normal, with major osteolytic X-rays lesions in 3 cases, minor in 2 cases, and isolated cold abcesses in two more cases: these means 7 false-negative results. Among the 30 other cases, 29 were considered as mechanical vertebral pathology, and 1 sacro-iliitis Brucellosis. Bone scan was normal in 28 cases the 2 others are unexplained false-positive. Although non-specific and not completely reliable, we think that bone-scanning is useful in bone-tuberculosis check-up, especially to obtain early diagnosis and detect multifocal localisations.

  20. An experimental study on the application of radionuclide imaging in repair of the bone defect

    Directory of Open Access Journals (Sweden)

    Weimin Zhu

    2011-08-01

    Full Text Available The aim of our study was to validate the effect of radionuclide imaging in early monitoring of the bone’s reconstruction, the animal model of bone defect was made on the rabbits repaired with HA artificial bone. The ability of bone defect repair was evaluated by using radionuclide bone imaging at 2, 4, 8 and 12 weeks postoperatively. The results indicate that the experimental group stimulated more bone formation than that of the control group. The differences of the bone reconstruction ability were statistically significant (p<0.05. The nano-HA artificial has good bone conduction, and it can be used for the treatment of bone defects. Radionuclide imaging may be an effective and first choice method for the early monitoring of the bone’s reconstruction.

  1. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L.; Wastie, M.L.; Forster, I

    2001-03-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of{sup 99}Tc{sup m}-MDP bone scintigraphy. METHOD: A retrospective study of all patients having a{sup 99}Tc{sup m}-MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  2. Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement

    International Nuclear Information System (INIS)

    Smith, S.L.; Wastie, M.L.; Forster, I.

    2001-01-01

    AIM: Post-arthroplasty knee pain is common and clinically it can be difficult to identify those patients with complications requiring active treatment. The aim of this study was to determine the usefulness of 99 Tc m -MDP bone scintigraphy. METHOD: A retrospective study of all patients having a 99 Tc m -MDP bone scintigram for a painful knee arthroplasty between 1993 and 1999 was performed. Bone scintigrams were classified as normal or abnormal by a single observer. The results of these investigations were correlated with clinical outcome. RESULTS: Seventy-five patients with painful knee arthroplasties were referred for investigation. A total of 80 bone scintigrams were performed. The average patient age was 66.2 years (42 female and 33 male). The mean time period between surgery and onset of knee pain was 3 years. A final clinical diagnosis based on arthroscopy, open surgery, and extended clinical follow-up was available for all patients. Forty-three (53.8%) of the scintigrams were normal and 37 (46.3%) abnormal. Two patients with a normal bone scintigram has loose prostheses. Thirteen patients with an abnormal study had normal prostheses on follow-up and these tended to be patients scanned less than a year after surgery. The sensitivity, specificity, positive predictive value and negative predictive value of an unequivocally normal or abnormal bone scintigram was 92.3, 75.9, 64.9 and 95.0%, respectively. The pattern of isotope uptake in the abnormal studies was not specific enough to reliably differentiate aseptic from septic loosening. CONCLUSION: Radionuclide bone scintigraphy is useful in the assessment of the painful knee arthroplasty. A negative bone scintigram is reassuring and makes loosening or infection unlikely. Smith, S.L. et al. (2001)

  3. Bone scan in diagnosis of inflammatory processes of the foot bones in diabetes mellitus

    International Nuclear Information System (INIS)

    Slavnov, V.M.; Markov, V.V.; Bolgars'ka, S.V.

    2003-01-01

    The radionuclide technique for early diagnosis of inflammatory process in the bones of the foot was developed for diabetes mellitus (DM) patients. The most important diagnostic criterion of the bone lesion in patients with DM is area asymmetry and total activity percentage between the lesion focus and symmetrical zone

  4. A comparison of bone scanning and radiology in the evaluation of patients with metabolic bone disease

    International Nuclear Information System (INIS)

    Fogelman, I.; Carr, D.

    1980-01-01

    Bone scan and radiographs were evaluated in 80 patients with metabolic bone disease (27 with osteoporosis, 14 with primary hyperparathyroidism, 24 with renal osteodystrophy and 15 with osteomalacia). The bone scan did not suggest a metabolic bone disorder in any of 27 patients with histologically proven osteoporosis. In 22 (81%) patients radiographs were reported as showing osteoporosis. In 19 (70%) vertebral fractures were seen on X-ray while these were noted in 11 (41%) patients on the bone scan. Vertebral fractures were usually visualised on the bone scan when these had occurred less than one year previously. In primary hyperparathyroidism the bone scan was suggestive of a metabolic bone disorder in 7 of 14 (50%) patients, while radiographs were reported as showing evidence of hyperparathyrodism in three (21%) cases. The bone scan suggested the presence of a metabolic bone disorder in all 24 patients with renal osteodystrophy and 15 patients with osteomalacia while the correct diagnosis was obtained in 14 (58%) and nine (60%) of these patients on X-ray. It is concluded that the bone scan is the more sensitive investigation in patients with osteomalacia, primary hyperparathyroidism and renal osteodystrophy. For osteoporosis radiology is the investigation of choice but the bone scan may be of value in assessing the duration of vertebral collapse. (author)

  5. Carbon-11 in Bone and Lung Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Myers, W. G.; Hunter, Jr., W. W. [Ohio State University Health Center, Columbus, OH (United States)

    1969-05-15

    Radiocarbon-11 decays with 20.3-min half-life by emitting positrons with 1.0-MeV maximum energy. Two 511-keV {sup {+-}}{gamma}-photons almost always are emitted coincidentally with each disintegration, at 180 Degree-Sign to each other. This 'back-to-back' relationship makes it possible readily to locate small accumulations of {sup 11}C in vivo by opposed detectors connected by coincidence circuitry. The calculated narrow-beam half-thickness in water is more than 7 cm, to provide good penetration from deep organs, and with little scatter. Multimillicurie amounts of a mixture of {sup 11}CO and {sup 11}CO{sub 2} are generated readily in our small cyclotron when probe targets of B{sub 2}O{sub 3} are bombarded with protons, deuterons, or {sup 3}He{sup ++} ions. The {sup 11}CO is oxidized to {sup 11}CO{sub 2} by hopcalite placed in the vacuum line. Dogs with primary or metastatic bone tumours received {sup 11}CO{sub 2}, either by inhalation in a closed system, or in slightly basic solution in travenously. Scintigraphs, that were obtained within 10-20 min by means of a Nuclear-Chicago focused-collimator scanning machine, revealed significant accumulations of {sup 11}C at sites where bone erosion was demonstrable roentgenographically. Good pictures of dog lungs were obtained either with the mechanical scanner, or with our Nuclear-Chicago scintillation camera, after intravenous injection of 4-12 {mu}m diam. smoothly-rounded aggregates of SrCO{sub 3} that were formed in dextran-saline solution. These 'photon-carrier' aggregates have been made either with {sup 11}C; or with 2.8-h {sup 87m}Sr, which emits 388-keV gamma-rays. Alternatively, they might be made to 'carry' the 231-keV gamma-rays of 70-m in {sup 85m}Sr, that are advantageous for scintigraphy. The advent of Anger's positron camera, with choice of plane of prime interest, will provide opportunities to emphasize the maximum target/nontarget ratio in pictures of localized accumulations of {sup 11}C, as well as of {sup

  6. Bone position emission tomography with or without CT Is more accurate than bone scan for detection of bone metastasis

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Lee, Wom Woo; Kim, Sang Eun

    2013-01-01

    Na1 8F bone positron emission tomography (bone PET) is a new imaging modality which is useful for the evaluation of bone diseases. Here, we compared the diagnostic accuracies between bone PET and bone scan for the detection of bone metastasis (BM). Sixteen cancer patients (M:F = 10:6, mean age = 60 ± 12 years) who underwent both bone PET and bone scan were analyzed. Bone PET was conducted 30 minutes after the injection of 370 MBq Na1 8F , and a bone scan was performed 3 hours after the injection of 1295 MBq 9 9mT c-hydroxymethylene diphosphonate. In the patient-based analysis (8 patients with BM and 8 without BM), the sensitivities of bone PET (100% 8/8) and bone scan (87.5% = 7/8) were not significantly different (p > 0.05), whereas the specificity of bone PET (87.5% = 7/8) was significantly greater than that of the bone scan (25% = 2/8) (p 8F bone PET is more accurate than bone scan for BM evaluation.

  7. Early Diagnosis of Avascular Necrosis of Bone Following Renal Transplantation By Bone Scan

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyun Ho; Kim, Han Su; Ihn, Chun Gyoo; Kim, Myung Jae [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    Avascular necrosis of bone has become a well-recognized complication of renal transplantation. While preexisting metabolic bone disease, especially hyperparathyroidism, and metabolic disturbances induced by steroids have been implicated as etiological factors, the pathogenesis is controversial. The diagnosis of avascular necrosis of bone had been based on a history of joint pain and radiographic demonstration of bone necrosis. Recently the bone scan using {sup 99m}Tc-methylene diphosphonate is helpful in determining the early stage of bone necrosis. We report two cases of avascular necrosis of femur head, of which diagnosis was made by the bone scan using {sup 99m}Tc-methylene diphosphonate.

  8. Early Diagnosis of Avascular Necrosis of Bone Following Renal Transplantation By Bone Scan

    International Nuclear Information System (INIS)

    Shin, Hyun Ho; Kim, Han Su; Ihn, Chun Gyoo; Kim, Myung Jae

    1982-01-01

    Avascular necrosis of bone has become a well-recognized complication of renal transplantation. While preexisting metabolic bone disease, especially hyperparathyroidism, and metabolic disturbances induced by steroids have been implicated as etiological factors, the pathogenesis is controversial. The diagnosis of avascular necrosis of bone had been based on a history of joint pain and radiographic demonstration of bone necrosis. Recently the bone scan using 99m Tc-methylene diphosphonate is helpful in determining the early stage of bone necrosis. We report two cases of avascular necrosis of femur head, of which diagnosis was made by the bone scan using 99m Tc-methylene diphosphonate.

  9. Semi-quantitative interpretation of the bone scan in metabolic bone disease

    Energy Technology Data Exchange (ETDEWEB)

    Fogelman, I; Turner, J G; Hay, I D; Boyle, I T [Royal Infirmary, Glasgow (UK). Dept. of Nuclear Medicine; Citrin, D L [Wisconsin Univ., Madison (USA). Dept. of Human Oncology; Bessent, G R

    1979-01-01

    Certain easily recognisable features are commonly seen in the bone scans of patients with metabolic bone disorders. Seven such features have been numerically graded by three independent observers in the scans of 100 patients with metabolic bone disease and of 50 control subjects. The total score for each patient is defined as the metabolic index. The mean metabolic index for each group of patients with metabolic bone disease is significantly greater than that for the control group (P < 0.001). (orig.).

  10. Use of Gamma Correction Pinhole Bone Scans in Trauma

    International Nuclear Information System (INIS)

    Bahk, Youg Whee; Chung, Youg An; Park, Jung Mee

    2012-01-01

    99 mTc hydroxydiphosphonate (HDP) bone scanning is a classic metabolic nuclear imaging method and the most frequently performed examination. Clinically, it has long been cherished as an indispensable diagnostic screening tool and for monitoring of patients with bone, joint, and soft tissue diseases. The HDP bone scan, the pinhole scan in particular, is known for its ability to detect increased, decreased, or defective tracer uptake along with magnified anatomy. Unfortunately, however, the findings of such uptake changes are not specific in many traumatic bone disorders, especially when lesions are minute and complex. This study discusses the recently introduced gamma correction pinhole bone scan (GCPBS), emphasizing its usefulness in the diagnosis of traumatic bone diseases including occult fractures; and fish vertebra. Indeed, GCPBS can remarkably enhance the diagnostic feasibility of HDP pinhole bone scans by refining the topography, pathologic anatomy, and altered chemical profile of the traumatic diseases in question. The fine and precise depiction of anatomic and metabolic changes in these diseases has been shown to be unique to GCPBS, and they are not appreciated on conventional radiographs, multiple detector CT, or ultrasonographs. It is true that MR imaging can portray proton change, but understandably, it is a manifestation that is common to any bone disease

  11. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  12. Correlation between PSA, bone scan and Gleason score in patients with prostate cancer

    International Nuclear Information System (INIS)

    Mendoza, G.; Cano, R.; Morales, R.; Munoz, L.; Saavedra, P.; Aguilar, C.

    2004-01-01

    Full text: Prostate cancer is the third most common cancer among Peruvian males. Although radionuclide bone scans (BS) are frequently recommended as part of the staging evaluation for newly diagnosed prostate cancer, most scans are negative for metastases. It has been suggested that a routine bone scan is unnecessary in recently diagnosed prostate cancer if serum PSA is under 10 ng/mL. We hypothesized that Gleason score plus prostate-specific antigen (PSA), could predict for a positive bone scan (better that PSA alone), and that a low - risk group of patients could be identified in whom BS might be omitted. All patients who had both pathologic review of their prostate cancer biopsies and radionuclide BS at our institution from 1/93 to 12/95 were studied. Gleason score, PSA, and bone scan (Soloway Index) were determined in 165 patients. Bivariate analysis using chi (x2) was performed. The mean age of the 165 patients was 71.3 years, 109/165 (66.1%) had a 7-9 Gleason score and only 9/165 (5.5%) were well differentiated prostrate cancer. 82/165 (49.7%) had negative BS. When classifying patients according to their histological grade, the PSA median values were 11.8 ng/mL, 74.8 ng/mL and 116.4 ng/mL in well, median and poorly differentiated prostate cancer respectively. Using a cut off point of 10 ng/mL of PSA, the probability of having a positive BS in Gleason 7, 8 and 9 tumors were 0.109, 0.121 and 0.133 respectively. By using a cut off point of 20 ng/mL of PSA the possibility to have a positive BS in Gleason 7, 8 and 9 tumours were 0.182, 0.206 and 0.224 respectively. Gleason score plus PSA were independent predictors for a positive radionuclide BS in newly diagnosed prostate cancer patients. Considering that most of our patients have Gleason 7-9, the risk of bone metastases despite PSA levels between 10 - 20 ng/mL is not negligible. In our opinion, it is important to continue including bone scan in the staging assessment of prostate cancer. (author)

  13. Pathophysiologic basics and diagnostic limits of conventional bone scanning

    International Nuclear Information System (INIS)

    Schuemichen, C.; Dunkelmann, S.

    2006-01-01

    Normal bone scan demonstrates the physiological regional bone formation rate, which is related to bone remodeling and maintenance of calcium homeostasis. Osteotrope radiopharmaceuticals can be used as a perfusion marker as well as a marker of regional bone formation rate. Local hyperperfusion without increased bone formation is seen in disuse atrophy and reflex sympathic dystrophy, which are difficult to discriminate, local hypoperfusion is responsible for false negative results in osteomyelitis. A local increased bone formation rate is the substrate of a positive finding in bone fracture, inflammation, tumors, metastases and other lesions. In direct comparison with other imaging modalities (MRT, scintigraphy with non-osteotrope radiopharmaceutical and PET, but not CT and multislice-CT), planar bone scintigraphy shows an unexpected deficiency in sensitivity, which can be almost or completely overcome by using SPECT or even better 18 F-fluoride PET. These techniques will also improve specificity, which still is a weak point of bone scanning, despite improved imaging performance and a huge experience in this field. The introduction of SPECT/CT und PET/CT in bone scanning will be even more desirable for this reason. (orig.)

  14. Dynamic computed tomography scanning of benign bone lesions: Preliminary results

    International Nuclear Information System (INIS)

    Levine, E.; Neff, J.R.

    1983-01-01

    The majority of benign bone lesions can be evaluated adequately using conventional radiologic techniques. However, it is not always possible to differentiate reliably between different types of benign bone lesions on the basis of plain film appearances alone. Dynamic computed tomography (CT) scanning provides a means for further characterizing such lesions by assessing their degree of vascularity. Thus, it may help in distinguishing an osteoid osteoma, which has a hypervascular nidus, from a Brodie's abscess, which is avascular. Dynamic CT scanning may also help in the differentiation between a fluid-containing simple bone cyst, which is avascular, and other solid or semi-solid benign bone lesions which slow varying degrees of vascularity. However, because of the additional irradiation involved, dynamic CT scanning should be reserved for evaluation of selected patients with benign bone lesions in whom the plain film findings are not definitive and in whom the CT findings may have a significant influence on management. (orig.)

  15. Report on intercomparison A-12 of the determination of radionuclides in animal bone

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1982-12-01

    It is widely recognised that radionuclides contained in food are responsible for the major part of the radiation dose which the human population has received through the development of atomic energy for military purposes. Some of them, such as strontium-89 and -90 or naturally occurring radium-226 and -228, follow calcium into bone and are retained there for long periods. Their expanded radiation may affect the bone and bone-marrow cells. Leukaemia and bone cancer are sometimes considered as a consequence of ingestion of fission products. Many medical and biological laboratories are obliged to determine radionuclides in bone and have to check the accuracy of their results. To meet their needs, the IAEA's Analytical Quality Control Service organized intercomparisons of the determination of fission products and natural radionuclides in calcinated animal bone

  16. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration. [Preoperative scanning

    Energy Technology Data Exchange (ETDEWEB)

    Heslinga, J M; Pauwels, E K.J.; Zwaveling, A [Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis

    1982-06-05

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period.

  17. Abnormal radionuclide cerebral angiograms and scans due to seizures

    International Nuclear Information System (INIS)

    Stevens, J.S.; Mishkin, F.S.

    1975-01-01

    The effect of recent seizures on the brain scan was determined in a retrospective study of patients who had had seizures. All patients who underwent brain scanning within eight days of seizures and who did not have a specific intracranial lesion were included. The /sup 99m/Tc-pertechnetate cerebral angiogram and/or delayed scan was abnormal in 73 percent of 22 patients. The data suggest that if seizures occur within six days of the brain imaging, the image is likely to be abnormal. (auth)

  18. Tumor markers and bone scan in breast cancer patients

    International Nuclear Information System (INIS)

    Ugrinska, A.; Vaskova, O.; Kraleva, S.; Petrova, D.; Smickova, S.

    2004-01-01

    Full text: The objective of this study was to compare the levels of CA15-3 and CEA with the bone scan findings in patients with breast cancer. Retrospective analysis of 76 bone scans from 61 patients diagnosed with breast cancer in the last 5 years was performed by two nuclear medicine specialists. All bone scans were performed after surgical treatment of the disease. Patients with loco-regional residual disease or distant metastases in the liver, lung or the brain were excluded from the study. According to the bone scan the patients were divided in 5 groups: normal bone scan (N), equivocal bone scan (E), single metastasis (1MS), three metastases (3MS) and multiple metastases (MMS). Tumor markers were determined within a month before or after the bone scan was performed. Cut-off value for CA 15-3 was 35 U/ml, and for CEA 3 ng/ml. Statistical analysis was performed using descriptive statistic and Kolmogorov-Smirnov test. Bone metastases were revealed in 38% of the patients referred for bone scintigraphy out of which 26% had MMS, 7.8% had single MS and 4% had 3MS. The results of 6.5% of the patients were determined as equivocal. The values of CA15-3 were higher in all patient groups compared with the group that had normal bone scan, but this difference reached statistical significance only in groups with 3MS and MMS (p < 0.01). The values of CEA were significantly higher only in patients with multiple metastases when compared with group N (p < 0.01). Values higher than cut-off value for CA 15-3 was found in 9 patients out of 42 in the group with normal bone scan. The highest value of CA 15-3 in this group was 47 U/ml. Only one patient in this group showed elevated levels for CEA. Three patients in the group with single metastasis had normal CA 15-3, while CEA was elevated only in one patient. All patients in the group with 3MS had elevated levels of CA 15-3 while CEA was in the normal range. All patients with MMS had elevated CA 15-3 values while CEA was elevated in

  19. Tumoral calcinoses in bone scanning: A case study

    International Nuclear Information System (INIS)

    Cook, P.

    1998-01-01

    Full text: Tumoral calcinosis (TC) is a rare disorder characterised by hyperphosphateamia, normocalceamia and calcified para-articular masses as seen on X-ray. At present, an inborn error of phosphorous metabolism is accepted as the primary cause. Symptoms include pain, swelling, infection and single- or multi-focal lesions. Radionuclide imaging was recently described as the most reliable and simplest method for detection, localisation and assessment of the calcific masses. Bone scintigraphy may demonstrate unsuspected masses even when clinical examination is negative. It is also useful in assessing the effects of surgery and therapy. A 55-year-old male with an 18-year history of TC presented to our department on two occasions. He was first referred to assess the extent of his calcinosis. He had known involvement of the hands, shoulders and pelvis, with little restriction of movement. He had a 6-8 year history of polio which was currently stable. Seven years later he again presented to our department, this time for the evaluation of a suspected fractured hip. On both occasions 800 MBq of 99 mTc-MDP was injected IV and whole body and planar images were obtained at three hours. In the second study, additional dynamic and blood pool images were obtained over the anterior aspect of both hips. Both scans were grossly abnormal and typical of the appearance of widespread TC or calcinosis universalis. Multiple areas of extra osseous uptake involving subcutaneous tissue and muscle of the hands, para-articular regions of both elbows, shoulders and hips were seen and confirmed by X-ray. Localised abnormalities were noted involving left lower neck, left forearm and left foot. Marked progression of the disease was seen in the region of the left shoulder on the second scan. No abnormalities were noted within the skeleton itself. Neither the dynamic nor blood pool phase of the study demonstrated significant hyperaemia in the region of the left proximal femur. Although the second

  20. Tumoral calcinoses in bone scanning: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Cook, P. [Royal Prince Alfred Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-03-01

    Full text: Tumoral calcinosis (TC) is a rare disorder characterised by hyperphosphateamia, normocalceamia and calcified para-articular masses as seen on X-ray. At present, an inborn error of phosphorous metabolism is accepted as the primary cause. Symptoms include pain, swelling, infection and single- or multi-focal lesions. Radionuclide imaging was recently described as the most reliable and simplest method for detection, localisation and assessment of the calcific masses. Bone scintigraphy may demonstrate unsuspected masses even when clinical examination is negative. It is also useful in assessing the effects of surgery and therapy. A 55-year-old male with an 18-year history of TC presented to our department on two occasions. He was first referred to assess the extent of his calcinosis. He had known involvement of the hands, shoulders and pelvis, with little restriction of movement. He had a 6-8 year history of polio which was currently stable. Seven years later he again presented to our department, this time for the evaluation of a suspected fractured hip. On both occasions 800 MBq of {sup 99}mTc-MDP was injected IV and whole body and planar images were obtained at three hours. In the second study, additional dynamic and blood pool images were obtained over the anterior aspect of both hips. Both scans were grossly abnormal and typical of the appearance of widespread TC or calcinosis universalis. Multiple areas of extra osseous uptake involving subcutaneous tissue and muscle of the hands, para-articular regions of both elbows, shoulders and hips were seen and confirmed by X-ray. Localised abnormalities were noted involving left lower neck, left forearm and left foot. Marked progression of the disease was seen in the region of the left shoulder on the second scan. No abnormalities were noted within the skeleton itself. Neither the dynamic nor blood pool phase of the study demonstrated significant hyperaemia in the region of the left proximal femur. Although the

  1. Diverse bone scan abnormalities in shin splints

    International Nuclear Information System (INIS)

    Spencer, R.P.; Levinson, E.D.; Baldwin, R.D.; Sziklas, J.J.; Witek, J.T.; Rosenberg, R.

    1979-01-01

    Four young patients who presented with pain over the anterior compartment of the legs, gave a recent athletic history suggesting stress fractures. Although radiographs were initially normal in all four cases, the bone scintigrams were positive. The individual findings, however, were quite different. In one there was a single focal area of increased radioactivity in each of the tibias; the second patient had uneven uptake of radiotracer and several foci of accumulation in the fibulas; the third showed diffuse linear tibial uptake suggesting periosteal lesions; and the fourth case revealed uptake in the lateral malleolus and in bones of the foot

  2. CT-scanning of ancient Greenlandic Inuit temporal bones

    International Nuclear Information System (INIS)

    Homoe, P.; Videbaek, H.

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.)

  3. CT-scanning of ancient Greenlandic Inuit temporal bones

    Energy Technology Data Exchange (ETDEWEB)

    Homoe, P [Copenhagen Univ. (Denmark). Lab. of Biological Anthropology and Dept. of Otolaryngology, Head and Neck Surgery; Lynnerup, N [Copenhagen Univ., Lab. of Biological Anthropology and Univ. Inst. of Ferensic Medicine, Copenhagen (Denmark); Videbaek, H [Hvidovre Univ. Hospital, Copenhagen (Denmark). Dept. of Radiology

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.).

  4. Skeletal blood flow: implications for bone-scan interpretation

    International Nuclear Information System (INIS)

    Charkes, N.D.

    1980-01-01

    The dispersion of the skeleton throughout the body and its complex vascular anatomy require indirect methods for the measurement of skeletal blood flow. The results of one such method, compartmental analysis of skeletal tracer kinetics, are presented. The assumptions underlying the models were tested in animals and found to be in agreement with experimental observations. Based upon the models and the experimental results, inferences concerning bone-scan interpretation can be drawn: decreased cardiac output produces low-contrast (technically poor) scans; decreased skeletal flow produces photon-deficient lesions; increase of cardiac output or of generalized systemic blood flow is undetectable 1 to 2 h after dose; increased local skeletal blood flow results from disturbance of the bone microvasculature and can occur from neurologic (sympatholytic) disorders or in association with focal abnormalities that also incite the formation of reactive bone (e.g., metastasis, fracture, etc.). Mathematical solutions of tracer kinetic data thus become relevant to bone-scan interpretation

  5. Does aspiration of bones and joints affect results of later bone scanning

    International Nuclear Information System (INIS)

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan

  6. Bone Marrow Scans with Colloidal {sup 198}Au

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sung Soo; Whang, Kee Suk [Kyungpook National University College of Medicine, Daegu (Korea, Republic of)

    1973-03-15

    The bone marrow scans with colloidal {sup 198}Au were performed on 33 cases with hematologically normal patients and patients with various blood dyscrasia. Bone marrow aspirations were done at iliac crest in all cases but one. A correlation between the scan findings and an erythroid cellularity was evaluated. The following results were obtained. 1) Out of 33 cases, 23 (about 70%) showed a correlation between {sup 198}Au marrow uptakes on the scans and the erythroid cellularity. 2) The diseases in which no correlation existed between {sup 198}Au uptake and erythroid cellularity were aplastic anemia, acute leukemia and chronic myelogenous leukemia.

  7. [Scanning electron microscopy of heat-damaged bone tissue].

    Science.gov (United States)

    Harsanyl, L

    1977-02-01

    Parts of diaphyses of bones were exposed to high temperature of 200-1300 degrees C. Damage to the bone tissue caused by the heat was investigated. The scanning electron microscopic picture seems to be characteristic of the temperature applied. When the bones heated to the high temperature of 700 degrees C characteristic changes appear on the periostal surface, higher temperatura on the other hand causes damage to the compact bone tissue and can be observed on the fracture-surface. Author stresses the importance of this technique in the legal medicine and anthropology.

  8. The Usefulness of Bone Scan in Electric Burns

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo

    1996-01-01

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  9. The Usefulness of Bone Scan in Electric Burns

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; So, Yong Seon; Kweon, Ki Hyeon; Han, Sang Woong; Kim, Seok Hwan; Kim, Jong Soon; Han, Seung Soo [Hanil Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as determining to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites and bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, scrum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  10. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  11. Radionuclide scanning in the diagnosis of splenic injury: a case report

    International Nuclear Information System (INIS)

    Naga, A.H.; Boyette, E.L.; Broadrick, G.L.

    1977-01-01

    Blunt abdominal trauma may lead to rupture of the spleen with major bleeding, minor laceration or intracapsular damage with delayed bleeding. At times diagnosis may be difficult delaying treatment. The safety, simplicity, rapidity and accuracy of radionuclide scanning when splenic injury is suspected are demonstrated in the case of a 7-year-old boy

  12. Scanning small angle X-ray scattering investigations of bone

    International Nuclear Information System (INIS)

    Rinnerthaler, S.

    1998-06-01

    An important characteristic of bone is its strength, which is determined by bone mass, architecture and material quality. From a physical point of view bone is a composite material consisting of an organic matrix (collagen) and of inlets of mineral crystals (hydroxyapatite). These components build up a hierarchical, heterogeneous structure. The size of the mineral crystals lies in the nano-meter range and can be investigated by positionsensitive Small-Angle X-ray Scattering (Scanning-SAXS) in a non-destructive way. The average thickness, the degree and direction of the predominant orientation, as well as some information about shape and arrangement of the mineral crystals were determined in bones of humans, mice, and baboons by Scanning-SAXS with respect to age, bone diseases (osteogenesis imperfecta, pycnodysostosis) or medical treatments (fluoride or alendronate) of osteoporosis. The crystal thickness and the degree of orientation is much smaller in young individuals than in adults and the predominant orientation of the mineral crystals is different in a mixture of bone and mineralized cartilage compared to bone. Further, because position-resolved measurements are now possible, results from Scanning-SAXS measurements could be compared with the results of other position resolved methods. Due to this new feature it was possible, for the first time, to correlate directly 'mottled' bone visible in back-scattered electron imaging with small η-parameters evaluated from SAXS-patterns and the course of the collagen fibers with the predominant orientation of the mineral crystals. Scanning-SAXS proved to be a powerful tool to characterize bone nano-structure. (author)

  13. Clinical analysis of bone scanning in solitary lesion

    International Nuclear Information System (INIS)

    Zhu Jun; Zhu Ruisen; Zhu Jifang

    2002-01-01

    A rational analysis procedure for solitary lesions on whole bone scanning was offered. This study was undertaken to analyze retrospectively solitary lesions which obtained final diagnose through the following aspects: (1) diagnosis of bone metastasis, (2) the incidence of bone metastasis in different tumor, (3) the most possible lesion sites indicating bone metastasis, (4) morphological analysis of solitary lesions. The results are: (1) The incidence of solitary lesions in 2465 cases on whole bone scanning is 15.3%. (2) The rate of bone metastasis is 24.8% in 282 patients with primary malignancy. The rate of bone metastasis of 6.3% in 64 patients without primary malignancy, and the total diagnostic rate of bone metastasis is 21.4% in 346 patients. (3) In patients with primary malignancy, the incidence of bone metastasis of solitary lesions is as follows respectively; bronchi cancer 36.1%(22/61); breast cancer 23.8%(20/84); prostate gland 17.2%(5/29); other urinary system cancer 22.2%(4/18); G.I. system cancer 16.9%(10/59); others 29.0%(9/31). There is no significant difference in different cancer. (4) In patients without primary malignancy, 93.7%(60/64) of solitary lesions are benign. (5) From anatomical point of view, the authors found the diagnostic rate of bone metastasis is as follow: 30% in spine; 34.2% in pelvis; 36.4% in skull; 10.8% in other bones. There are significant differences in four groups. It is concluded that: (1) The diagnostic rate of bone metastasis in solitary lesions is 21.4%. (2) The most possible solitary lesions indicating osseous tumor spread are at spine, pelvic and skull. (3) Special attention to 'cold' and streak like lesions should be paid. (4) A clinical analysis procedure for diagnosis of solitary lesions has been summarized out here

  14. Lung uptake in bone scan - Two case reports

    International Nuclear Information System (INIS)

    Nahar, N.; Kabir, F.; Islam, N.; Karim, M.A.

    2001-01-01

    Breast cancer is the 2nd most common cancer in female in our country. When a case of breast cancer is diagnosed a base line bone scan is asked for to exclude skeletal metastasis. This helps for treatment planning and future follow up. Scan pattern in bone metastasis is usually multiple, randomly distributed foci of intensely increased tracer accumulation. Uptake of radio pharmaceutical in breast tissue is frequently observed. Kidneys are another extra skeletal organs through which 99m Tc-MDP is excreted and that's why normal kidneys are faintly visualized in delayed views suggesting normal exertion of tracer. If there is any outflow obstruction in any kidney, it will show hold up of radiotracer on that side. Often radiopharmaceuticals are seen to accumulate in other organs like lungs. Here two cases of breast cancer are discussed where bone scan shows significant uptake of tracer in lungs

  15. Bone scan and SPECT/CT findings in marble bone disease

    Energy Technology Data Exchange (ETDEWEB)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram [Jaslok Hospital and Research Centre, Woril (India)

    2012-03-15

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ({sup 99m}Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  16. Bone scan and SPECT/CT findings in marble bone disease

    International Nuclear Information System (INIS)

    Kapoor, Jiten; Joshi, Prathamesh; Lele, Vikram

    2012-01-01

    Marble bone disease or osteopetrosis, is a rare inborn disorder characterized by the failure of osteoclasts to resorb bone. Overall incidence of the disease is estimated to be 1 case in 100,000-500,000 population. Whereas the radiographic features of the disease are well known, information on bone scan imaging is sparse in the literature. We present technitium 99m methylene diphosphonate ( 99m Tc MDP) bone scan features of osteopetrosis, along with single photon emission computed tomography-computed tomography(SPECT/CT) correlation in a young male.

  17. Retrospective study of renal images on whole bone scanning

    International Nuclear Information System (INIS)

    Yanagisawa, Munetoshi; Machida, Toyohei; Miki, Makoto; Ohishi, Yukihiko; Ueda, Masataka

    1978-01-01

    One hundred and twenty-seven cases were surveyed by sup(99m)Tc-pyrophosphate at Jikei hospital. Renal images on whole-bone scanning were observed in all cases; 75% of all renal images were normal and 25% were abnormal. Thirteen percent of these abnormal images were symmetric and 87% were asymmetric. Four of the symmetric renal images were bilaterally bad. Three of the four bilaterally bad renal images involved prostate carcinomas with general metastases and the last involved serious bilateral hydronephrosis. The reason for the high percentage of asymmetric renal images was that the materials involved many urogenital cases. Asymmetric renal images other than the urogenital cases, were recognised in 8% of all cases. This percentage is consistent with Hattner's report. Unilateral abnormal renal images involved 8 hydronephrosis cases, 2 unilateral nonfunctioning kidneys and one malrotation kidney. Among the hydronephrosis cases, serious cases gave low uptake and mild cases gave high uptake. The reason for this phenomenon was, presumably, that there were differences in renal uptake, renal excretion and renal pelvic accumulation. In nine cases, one kidney was not visualized on whole-bone scanning, 8 of them involved nephrectomy and the remainining one unilateral nonfunctioning kidney. Six cases presented locally abnormal renal images on whole-bone scanning, three of them suffered renal cell carcinomas and the rest renal solitary cyst. Eighty-eight percent of the abnormal renal images agreed with IVP findings. The renal images of whole-bone scanning faithfully reflected the original renal lesion. Two cases of renal carcinoma and renal solitary cyst recognized on whole-bone scanning are presented, to indicate the usefulness of renal images on whole-bone scanning. (auth.)

  18. A negative bone scan leads to an unusual diagnosis

    International Nuclear Information System (INIS)

    O'Brien, L.

    1998-01-01

    Full text: A bone scan looking for osteomyelitis or a more sinister pathology was performed on a 7-year-old boy with Von Willebrand''s disease. He presented with symptoms of pain in the left groin and a lump, although there had been no history of direct trauma, and an X-ray report stating that there was an irregular ill-defined area of bony destruction seen in the lower aspect of the left ischium. Blood pool images of the pelvis were acquired soon after an injection of MDP and three hours later a whole body bone scan was done. Results of the bone scan showed that the radiolucent lesion in the left ilium seen on the plain radiographs was not metabolically active on the technetium MDP study. Features compatible with a response to an intraosseous or sub-periosteal haematoma were seen when reviewing the original X-rays and, as there was a spontaneous resolution of the patient''s symptoms, this was considered to be the diagnosis. This study shows that a negative bone scan, which rules out an active bone lesion, is of value in making a diagnosis when used in conjunction with X-rays and a knowledge of the patient''s history

  19. Skeletal metastases in pancreatic carcinoma: study by isotopic bone scanning

    Energy Technology Data Exchange (ETDEWEB)

    Hatfield, D R; Deland, F H; Maruyama, Y

    1976-01-01

    A review of the literature of 2,155 reported patients with primary carcinoma of the pancreas, revealed 110 cases or 5 percent to have skeletal metastasis by radiographic or autopsy study. A study conducted over a 2 year period disclosed that 1 case of skeletal metastasis was detected by bone scanning in 16 patients with pancreatic carcinoma. This indicates a minimum skeletal metastasis rate of 6 percent. We feel these percentages are low and can be further defined by the more routine employment of the bone scan to evaluate patients with carcinoma of the pancreas. The true figure may be much higher, perhaps as high as 20 percent.

  20. Radionuclide Treatment with 153Sm-EDTMP is Effective for the Palliation of Bone Pain in the Context of Extensive Bone Marrow Metastases: A Case Report

    International Nuclear Information System (INIS)

    Kairemo, Kalevi; Rasulova, Nigora; Suslaviciute, Justina; Alanko, Tuomo

    2014-01-01

    Radionuclide therapy is widely used as an effective modality in the management of bone pain. The main indication for this treatment is symptomatic bone metastases, confirmed by bone scintigraphy. We present a case of small cell lung cancer (SCLC) stage T 4 N 2 M 1b , with a good metabolic response to systemic therapy and radiotherapy of the primary tumor and locoregional disease, which became metabolically less active and remarkably smaller in size (reduction to 1/6 of the original volume). In spite of the good overall response, the patient developed a syndrome with severe bone pain and had progression in the bone marrow metastases, confirmed by 18 F-FDG PET/CT. The patient received 153 Sm-EDTMP treatment with a good clinical response. However, in the whole body bone scan with the therapeutic dose, there was no visual evidence of bone metastasis. Retrospectively, by drawing the region of interest, it was possible to identify one metastatic site. The possible mechanisms of the efficacy of this treatment modality, in this specific setting, are also discussed

  1. The usefulness of measurement of whole body count in assessing bone marrow metastasis in cancer patients with increased periarticular bone uptake on follow-up bone scan: a comparison with bone marrow scan

    International Nuclear Information System (INIS)

    Jin, Seong Chan; Choi, Yun Young; Cho, Suk Shin

    2003-01-01

    Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung canner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases

  2. Confocal laser scanning microscopy in study of bone calcification

    Science.gov (United States)

    Nishikawa, Tetsunari; Kokubu, Mayu; Kato, Hirohito; Imai, Koichi; Tanaka, Akio

    2012-12-01

    Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 μm/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  3. Differential diagnosis of metastases in bone scans: chemotherapy induced bone necrosis

    International Nuclear Information System (INIS)

    Reuland, P.

    1999-01-01

    Aim: Influenced by the incorrect diagnosis of a bone metastasis caused by bone necrosis we evaluated reasons and frequency of bone necrosis in patients referred for bone scanning in follow-up of tumors. Methods: Bone scans performed within two years on patients with primary bone tumors or tumors metastatic to bone were reviewed in respect to the final diagnosis bone necrosis. Results: We found the cases of three young patients who presented the appearance of hot spots on bone scintigrams which were finally diagnosed as bone necrosis. In two cases the diagnosis was based on histological findings, in one case the diagnosis was made evident by follow-up. All the three patients had been treated by chemotherapy and presented no other reason for the development of bone necrosis. Enhanced tracer uptake in all sites decreased within eight weeks up to two years without therapy. Conclusion: Single and multiple hot spots after chemotherapy may be originated by bone necrosis but mimikry metastases. (orig.) [de

  4. Confocal laser scanning microscopy in study of bone calcification

    Energy Technology Data Exchange (ETDEWEB)

    Nishikawa, Tetsunari, E-mail: tetsu-n@cc.osaka-dent.ac.jp [Department of Oral Pathology, Osaka Dental University, Osaka (Japan); Kokubu, Mayu; Kato, Hirohito [Department of Oral Pathology, Osaka Dental University, Osaka (Japan); Imai, Koichi [Department of Biomaterials, Osaka Dental University, Osaka (Japan); Tanaka, Akio [Department of Oral Pathology, Osaka Dental University, Osaka (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer High-magnification images with depth selection, and thin sections were observed using CLSM. Black-Right-Pointing-Pointer The direction and velocity of calcification of the bone was observed by administration of 2 fluorescent dyes. Black-Right-Pointing-Pointer In dog femora grafted with coral blocks, newly-formed bone was observed in the coral block space with a rough surface. Black-Right-Pointing-Pointer Twelve weeks after dental implant was grafted in dog femora, the space between screws was filled with newly-formed bones. - Abstract: Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 {mu}m/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  5. Confocal laser scanning microscopy in study of bone calcification

    International Nuclear Information System (INIS)

    Nishikawa, Tetsunari; Kokubu, Mayu; Kato, Hirohito; Imai, Koichi; Tanaka, Akio

    2012-01-01

    Highlights: ► High-magnification images with depth selection, and thin sections were observed using CLSM. ► The direction and velocity of calcification of the bone was observed by administration of 2 fluorescent dyes. ► In dog femora grafted with coral blocks, newly-formed bone was observed in the coral block space with a rough surface. ► Twelve weeks after dental implant was grafted in dog femora, the space between screws was filled with newly-formed bones. - Abstract: Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 μm/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  6. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    Science.gov (United States)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  7. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  8. Dynamic bone scanning in the diagnosis and management of osteomyelitis

    International Nuclear Information System (INIS)

    Gandsman, E.J.; Deutsch, S.D.; Tyson, I.B.

    1982-01-01

    The procedure using 99m Tc-MDP (Methylene Diphosphonate) was divided into two parts: a dynamic portion designed to obtain data to calculate the blood flow to the specific bones or joints being evaluated and a static portion that consisted of a routine bone scan. This method was applied to 30 patients with osteomyelitis of various bones. The dynamic study showed a pronounced increase in flow on the affected side. This was accompanied always by a significant increase in flow in the areas proximal and distal to the area of involvement. Ten patients had sequential scans during the course of antibiotic treatment. In all ten patients the flow became more symmetrical during the course of the treatment indicating the effect of the antibiotics. In seven of these patients the flow became completely symmetrical at the end of the therapy. The static bone images remained unchanged during the antibiotic treatment and did not reflect its effect. The method of dynamic bone scanning in osteomyelitis thus provides a way to determine the effectiveness of antibiotic therapy

  9. Bone scan findings in hypervitaminosis D: case report

    International Nuclear Information System (INIS)

    Fogelman, I.; McKillop, J.H.; Cowden, E.A.; Fine, A.; Boyce, B.; Boyle, I.T.; Greig, W.R.

    1977-01-01

    Bone scans in three patients showed generalized symmetrical increased uptake of radiopharmaceutical by the skeleton and absent or faint kidney images. It is thought that these appearances may be attributable to excess vitamin D, and other possible contributing factors, including the presence of renal osteodystrophy, are discussed

  10. In vivo measurements of bone-seeking radionuclides. Progress report, September 1, 1977--February 28, 1979

    International Nuclear Information System (INIS)

    Cohen, N.

    1978-01-01

    Progress is reported on the following research projects: estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull; contribution from radionuclides in the thoracic skeleton to in vivo measurements of activity in the lung; design and optimization characterictics of in vivo detection system; development of a calibration phantom structure for determining activity deposited in the thoracic skeleton; computer assisted in vivo measurements of internally deposited radionuclides using dual-crystal scintillation detectors; low energy, photon-emitting nuclides; reference spectra library; and in vivo measurements of exposed individuals

  11. In vivo measurements of bone-seeking radionuclides. Progress report, September 1, 1977--February 28, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N.

    1978-11-01

    Progress is reported on the following research projects: estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull; contribution from radionuclides in the thoracic skeleton to in vivo measurements of activity in the lung; design and optimization characterictics of in vivo detection system; development of a calibration phantom structure for determining activity deposited in the thoracic skeleton; computer assisted in vivo measurements of internally deposited radionuclides using dual-crystal scintillation detectors; low energy, photon-emitting nuclides; reference spectra library; and in vivo measurements of exposed individuals. (HLW)

  12. Orthopedic applications of single photon emission computed Tomographic bone scanning

    International Nuclear Information System (INIS)

    Collier, B.D.

    1987-01-01

    When compared with planar bone scanning, single photon emission computed tomography (SPECT) has technical advantages of potential diagnostic significance. Planar imaging often superimposes substantial underlying or overlying activity on the bony structure of medical interest. SPECT, however, can be used to remove such unwanted activity. For example, in the hip the acetabulum extends downwards behind the femoral head. Therefore when using planar bone scanning techniques, the photon-deficient defect typical of avascular necrosis (AVN) of the femoral had may be obscured by activity originating in the underlying acetabulum. By using SPECT, underlying and overlying distributions of activity can be separated into sequential tomographic planes. For this reason SPECT facilitates the detection of AVN of the femoral head. When referring a patient without a history of malignancy for bone scanning, the orthopaedic surgeon usually has a specific clinical question involving a limited portion of the skeleton. Orthopaedic surgeons at their institution commonly use bone scanning to clarify the cause of back, hip or knee pain; to determine with a physiological test the significance of radiographic findings; and to establish the extent of disease at symptomatic skeletal sites such as the three compartments of the knee. In instances such as these, when clinical concern is limited to a specific anatomical region, a bone scan procedure that includes SPECT imaging of only a portion of the skeleton is appropriate. To date, SPECT of the skeletal system has most frequently been used to evaluate patients with pain the larger joints and bony structures such as the lumbar spine, hips, knees, or temporomandibular joints (TMJ)

  13. Three phase bone scan , Ga-67 and Tc-99m nanocoll scan in detection of osteomyelitis caused by war injuries

    International Nuclear Information System (INIS)

    Banek, T.; Reljica-Kostic, Z.; Kurnik, G.

    1994-01-01

    Thirty three injured soldiers were surgically treated because of pierce wounds of extremities. Treatment was either osteosynthesis or external fixation. Two to four weeks post treatment clinical signs of osteomyelitis appeared. X-ray was negative in all patients. Three-phase bone scan was performed in order to establish diagnosis. Bone scan was positive in all patients. For 11 patients only bone scan was sufficient for decision of further treatment. In 22 patients Ga-67 or Tc-99m- nanocoll or both examinations were performed on surgeon's request. In 2 patients out of 5 with additional Ga-67 scan, Ga-67 scan showed more lesions than it was seen on bone scan. In 3 patients out of 5 with additional Tc-99m-nanocoll scan, Tc-99m-nanocoll scan showed more lesions than it was seen on bone scan. In 12 patients with positive bone scan and negative or unclear Ga-67, Tc-99m-nanocoll scan was performed. In 5 out of 12 patients Tc-99m- nanocoll scan established diagnosis in others confirmed finding on bone and Ga-67 scan. Our results showed that in one third of our causes bone scan was sufficient for diagnosing of osteomyelitis caused by war injuries. In selected cases where bone scan was not sufficient for diagnosis and decision for treatment Tc-99m-nanocoll was more sensitive than Ga-67. In our experience three-phase bone scan is more sensitive than Ga-67. In our opinion three-phase bone scan is the method of choice for diagnosing osteomyelitis in war situation with a lot of casualties. (author)

  14. Bone scan and serum CA 15-3 in bone metastasis in breast cancer

    International Nuclear Information System (INIS)

    Mendoza, G.; Cano, R.; Morales, R.; Guzman, C.

    1996-01-01

    CA 15-3 is a tumor marker useful in evolution control of breast cancer, being the serum levels trend the most important parameter. The purpose of this study was to report our experience and show the concordance of bone scan and CA 15-3 in patients with breast cancer attending the Breast and Bone Department of INEN from June to December 1993. One hundred patients had serum CA 15-3 quantification between June and December of 1993 in Nuclear Medicine Center (Peruvian Institute of Nuclear Energy and National Institute of Neoplasic Diseases). We selected 52 patients which simultaneously had a bone scan performed. Patients age ranged from 21 to 67 years (media of 44,57 years). 99m Tc methylenediphosphonate produced by IPEN was the radiopharmaceutical employed. A GE AZS-400 gamma camera was utilized to obtain the bone scans. Ca 15-5 quantification was performed with ELSA-CA 15-3 (CIS bio France) IRMA kit. Bone scan and CA 15-3 media of 17,06 U/ml (DS 15,4). Eight patients had a positive bone scan with a CA 15-3 media of 41,6 U/ml (SD 23,0). CA 15-3 levels ranged between 4,6 and 96,0 U/ml in the first group and 10,1 U/ml to 75,0 U/ml in the second group. Using a cut-off point of 30 U/ml the sensitivity of CA 15-3 was 62,5% and the specificity 93,2% respectively. Mean CA 15-3 values of the negative and positive bone scan groups were significantly different (p=0,0361). The high negative predictive value of CA 15-3 may help to establish which patients will benefit from bone scan procedure. (authors) 42 refs., 2 tabs

  15. Comparison of radionuclide scans with computer-assisted tomography in diagnosis of intracranial disease

    International Nuclear Information System (INIS)

    Clifford, J.R.; Connolly, E.S.; Voorhies, R.M.

    1976-01-01

    Radionuclide brain scans were compared with computer-assisted tomography (CAT) for the diagnosis of intracranial disorders in 297 patients. The diagnosis was confirmed in 281 patients who formed the population for the study. The radionuclide scan was false positive for 12 patients (3.9 percent) and false negative for eight (2.6 percent). The CAT was false positive for three patients (1 percent) and false negative for one (0.3 percent). In the 133 patients in whom both tests were negative, no evidence of central nervous system pathology has been found during the 6 to 18 month follow-up. Brain tumors and intracerebral hemorrhage are more readily detectable with CAT

  16. Design and application of the MARK IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1976-01-01

    The MARK IV radioisotope scanning system was built to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as /sup 99m/Tc, but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a 4-sided arrangement of 32-independent detectors which continuously rotate as a unit, detecting, processing, and displaying the reconstructed data while the study progresses

  17. Calculated dose factors for the radiosensitive tissues in bone irradiated by surface-deposited radionuclides

    International Nuclear Information System (INIS)

    Spiers, F.W.; Whitwell, J.R.; Beddoe, A.H.

    1978-01-01

    The method of calculating dose factors for the haemopoietic marrow and endosteal tissues in human trabecular bone, used by Whitwell and Spiers for volume-seeking radionuclides, has been developed for the case of radionuclides which are deposited as very thin layers on bone surfaces. The Monte Carlo method is again used, but modifications to the computer program are made to allow for a surface rather than a volume source of particle emission. The principal change is the introduction of a surface-orientation factor which is shown to have a value of approximately 2, varying slightly with bone structure. Results are given for β-emitting radionuclides ranging from 171 Tm(anti Esub(β) = 0.025 MeV) to 90 Y(anti Esub(β) = 0.93 MeV), and also for the α-emitter 239 Pu. It is shown that where the particle ranges are short compared with the dimensions of the bone structures the dose factors for the surface seekers are much greater than those for the volume seekers. For long range particles the dose factors for surface- and volume-seeking radionuclides converge. Comparisons are given relating the dose factors calculated in this paper on the basis of measured bone structures to those of other workers based on single plane geometry. (author)

  18. Relevance and indications of the bone scan - an assessment

    International Nuclear Information System (INIS)

    Reinartz, P.; Buell, U.

    2002-01-01

    Due to its high sensitivity, the bone scan is one of the most frequently performed procedures in nuclear medicine. Although specificity is often criticized as its weak point, excellent results can be achieved under employment of modern acquisition techniques like SPECT imaging and multi-phased scintigraphy or under consideration of disease-specific scintigraphic patterns. Concerning the indication for a bone scan, the former rigid diagnostic plans are more and more replaced by flexible criteria or scores. This aspect as well as the growing use of CT and MRI leads to a slight decrease in the number of performed examinations. Further competition arises by the employment of positron emission tomography for the diagnosis of pathological osseous lesions using 18 F-FDG or 18 F-fluoride ion, especially in cases of malign or inflammatory disease. Although promising results have been achieved, it is doubtful whether PET will be able to replace bone scintigraphy, especially under consideration of the economic situation of the German health care system. In conclusion it can be stated that at least in the near future the conventional bone scan will remain an essential procedure within the realm of nuclear medicine. (orig.) [de

  19. Normal variants and artifacts in bone scan: potential for errors in interpretation

    International Nuclear Information System (INIS)

    Sohn, Myung Hee

    2004-01-01

    Bone scan is one of the most frequently performed studies in nuclear medicine. In bone scan, the amount of radioisotope taken up by lesion depends primarily on the local rate of bone turnover rather than on the bone mass. Bone scan is extremely sensitive for detecting bony abnormalities. However, abnormalities that appear on bone scan may not always represent disease. The normal scan appearances may be affected not only by skeletal physiology and anatomy but also by a variety of technical factors which can influence image quality. Many normal variants and artifacts may appear on bone scan. They could simulate a pathologic process and could mislead into the wrong diagnostic interpretation. Therefore, their recognition is necessary to avoid misdiagnosis. A nuclear medicine physician should be aware of variable appearance of the normal variants and artifacts on bone scan. In this article, a variety of normal variants and artifacts mimicking real pathologic lesion in bone scan interpretation are discussed and illustrated

  20. Evaluation of the Rib Lesions by Bone Scanning

    International Nuclear Information System (INIS)

    Park, Hyung Gun; Lee, Dong Soo; Lee, Myung Chul; Cho, Bo Youn; Koh, Chang Soon

    1983-01-01

    In order to establish criteria for distinguishing between occult fracture and metastases, we have reviewed 52 records of cancer patients and 24 of rib fracture patients referred for bone scanning. In 52 patients with biopsy-proven malignancy, multiple linear increased uptake of the ribs was found in 32 cases(61.5%), and was the most common finding. In 24 patients with rib fracture, all but 1 had fecal increased uptake of the ribs, and lesions almost always aligned in a row. By analyzing the appearance of rib lesions in total 76 patients, it was concluded that there is a high probability that rib lesions detected by bone scanning are bony metastases if 1) they are multiple linear as opposed to fecal, and 2) they are not aligned in the same location

  1. Clinical meaning of hot uptake on bone scan in symptomatic accessory navicular bones

    International Nuclear Information System (INIS)

    Chong, Ari; Ha, Jung Min; Lee, Jun Young

    2016-01-01

    We analyzed clinical factors related to uptake on a Tc-99 m HDP bone scan of the accessory navicular (AN). We retrospectively reviewed patients who had been examined by an orthopedic surgeon and underwent bone scan due to suspected symptomatic AN. A three-point grading system was used to evaluate uptake on bone scan. Relationships between grade, symptoms, age, gender, symptom duration, and bone size were analyzed. In total, 73 ANs (30 asymptomatic, 43 symptomatic) were enrolled. The majority of asymptomatic ANs had no uptake but some had grade 1 (n = 8) or 2 (n = 2) uptake. All asymptomatic ANs with uptake remained asymptomatic during follow-up. For the asymptomatic ANs, larger bones showed a higher grade. With a cut-off value of size ≤6.8 mm, there is no chance of uptake. All symptomatic ANs showed uptake on bone scan. For symptomatic ANs, larger size and shorter pain duration were related to a higher grade. Age, gender, and left-/right-sideness were not related to grade. Multiple regressions revealed that only uptake grade, not size or symptom duration, was the significant risk factor for a symptomatic AN. With a cut-off value of grade <1, a symptomatic AN could be ruled out with a negative predictive value of 100 %. Bone scanning is useful for symptomatic ANs with a high negative predictive value. Higher grade is related to larger size and shorter pain duration. For asymptomatic ANs, grade was related to size but did not predict symptom development

  2. Clinical meaning of hot uptake on bone scan in symptomatic accessory navicular bones

    Energy Technology Data Exchange (ETDEWEB)

    Chong, Ari; Ha, Jung Min; Lee, Jun Young [Chosun University Hospital, Gwangju (Korea, Republic of)

    2016-12-15

    We analyzed clinical factors related to uptake on a Tc-99 m HDP bone scan of the accessory navicular (AN). We retrospectively reviewed patients who had been examined by an orthopedic surgeon and underwent bone scan due to suspected symptomatic AN. A three-point grading system was used to evaluate uptake on bone scan. Relationships between grade, symptoms, age, gender, symptom duration, and bone size were analyzed. In total, 73 ANs (30 asymptomatic, 43 symptomatic) were enrolled. The majority of asymptomatic ANs had no uptake but some had grade 1 (n = 8) or 2 (n = 2) uptake. All asymptomatic ANs with uptake remained asymptomatic during follow-up. For the asymptomatic ANs, larger bones showed a higher grade. With a cut-off value of size ≤6.8 mm, there is no chance of uptake. All symptomatic ANs showed uptake on bone scan. For symptomatic ANs, larger size and shorter pain duration were related to a higher grade. Age, gender, and left-/right-sideness were not related to grade. Multiple regressions revealed that only uptake grade, not size or symptom duration, was the significant risk factor for a symptomatic AN. With a cut-off value of grade <1, a symptomatic AN could be ruled out with a negative predictive value of 100 %. Bone scanning is useful for symptomatic ANs with a high negative predictive value. Higher grade is related to larger size and shorter pain duration. For asymptomatic ANs, grade was related to size but did not predict symptom development.

  3. The Findings of 99mTc-MDP Bone Scan in Primary malignant Bone Tumors

    International Nuclear Information System (INIS)

    Hyun, In Young; Lee, Kung Han; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kang, Heung Sik; Lee, Sang Hoon; Lee, Han Koo

    1995-01-01

    Tc-99m-MDP bone scan was performed in 31 patients with primary malignant bone tumors, 22 patients with osteogenic sarcoma, 5 patients with chondrosarcoma and 4 patients with Ewing's sarcoma. The findings were classified by isotope intensity of accumulation in tumor as grade 1 to 3, overall pattern of isotope distribution in tumor as grade 1 to 3, and distortion of bony outline as grade 1 to 3. Histologic classifications were correlated with scan findings in 22 patients with osteogenic sarcoma. The results were as follows. 1) In 22 patients with osteogenic sarcoma, markedly increased isotope intensity higher than sacroiliac joint with patchy areas of decreased intensity and severe bony distortion were found in 16 patients. The correlations between histologic classification and scan findings were not discovered. 2) In 5 patients with chondrosarcoma, mildly increased isotope intensity with patchy areas of increased intensity and mild bony distortion were found in 4 patients. 3) In 4 patients with Ewing's sarcoma, markedly increased homogenous intensity with moderate bony distortion were found in 3 patients. Conclusively there were common findings in each 3 primary malignant bone tumors and Tc-99m-MDP bone scan was complemented with radiologic studies in differentiating primary malignant bone tumors.

  4. Diffusely increased uptake in the skull in normal bone scans

    International Nuclear Information System (INIS)

    Suematsu, Toru; Yoshida, Shoji; Motohara, Tomofumi; Fujiwara, Hirofumi; Nishii, Hironori; Komiyama, Toyozo; Yanase, Masakazu; Mizutani, Masahiro

    1992-01-01

    Diffusely increased skull uptake (a hot skull) is often seen in patients with bone metastases and metabolic disease. This finding is also, however, noticed in normal bone scans of aged women. To determine whether the hot skull could be considered a normal variant in elderly women and is associated to menopause, we studied 282 normal bone scans (166 women and 116 men without metabolic and hormonal disease; age range 11 to 84 yr). We divided the patients into eight age groups--ages 10-19, 20-29, 30-39, 40-49, 50-59, 60-69, 70-79, and 80-89 yrs. Measurements of skull uptake were obtained from anterior total body views using contrast-to-noise ratio (CNR). CNR for the skull was calculated using an equation. The sex dependent difference in skull uptake began to develop in the age group 30-39 yrs (p<0.05). The skull showed greater activity in women than in men for age groups from 30-39 to 80-89 yrs. In the age groups 50-59 and 60-69, the difference was particularly large (p<0.001). For women, the 50-59 yr age group had a significantly higher CNR than the 40-49 yr (p<0.01), 30-39 yr (p<0.05), and 20-29 yr age group (p<0.05). On the other hand, there was no significant difference between the 20-29 yr, 30-39 yr and 40-49 yr age groups. For men, the skull uptake was virtually unchanged with age. Our data strongly suggested that the hot skull in normal bone scan is related to menopausal estrogen deficiency. One should not necessarily regard it abnormal that elderly women suffer hot skull. (J.P.N.)

  5. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    International Nuclear Information System (INIS)

    Alexander, J.E.; Seibert, J.J.; Aronson, J.; Williamson, S.L.; Glasier, C.M.; Rodgers, A.B.; Corbitt, S.L.

    1988-01-01

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck

  6. Magnification bone scan of knees for knee pain evaluation

    International Nuclear Information System (INIS)

    Lee, Myoung Hoon; Park, Chan H.; Yoon, Seok Nam; Hwang, Kyung Hoon

    2001-01-01

    Knee pain is one of the common complaints of patients seen in our orthopedic clinic. Routine anterior and posterior views of whole body bone scan (WBBS) is often not sufficient in the evaluation of these patients. An ideal bone scan using pinhole collimator or single photon emission tomography (SPECT), however, is impractical and time consuming in busy nuclear medicine department with limited resources. Therefore, the aim of the study is to assess limited bone scan of knees with magnification (LNSKM) for knee pain evaluation. Technical aspect of LBSKM and diagnostic efficacy are discussed on this poster. Adult patients with knee pain were reffered for LBSKM from an orthopedic surgen specializing knees. Four hundred fifteen LBSKMs were performed since 1999. patients were given 740 MBq (20mCi) Tc-99m MDP intravenously and 3 hours later LBSKM was performed using a low energy high resolution parallel hole collimator and Siemens Orbitor camera. (Simens medical systems. Inc., Hoffman Estates, III., USA). Anterior view of the knees was taken for 5 min, without magnification and both lateral views of symptomatic knees were obtained with electronic magnification (1.25, upto 2.0) for 8 min each. Disease processes such as DJD, traumatic arthritis, P-F tendonitis, SONK, meniscus tear are detected and illustrated along with normal knee scan finding. We believe LBSKM may not be as good as SPECT or pinhole imaging of the knees in the evaluation of knee pain but superior to routine WBBS in the nuclear medicine department with limited resources of instrumentation and manpower

  7. Is there a place for radionuclide bone scintigraphy in the ...

    African Journals Online (AJOL)

    ... shown the importance of bone scintigraphy in the detection of fractures in radiographnegative skeletal trauma.T-3 The early detection and immobilisation of fractures of the scaphoid are thought to be essential in preventing the disabling sequelae of avascular necrosis and pseudo-arthrosis,4 Several studies allude to the

  8. Os trigonum syndrome: use of bone scan in the diagnosis

    International Nuclear Information System (INIS)

    Johnson, R.P.; Collier, B.D.; Carrera, G.F.

    1984-01-01

    The os trigonum is an accessory bone of the foot found in 7% of the normal adult population. It is located at the posterolateral projection of the talus, and can occasionally give rise to symptoms of acute and chronic unexplained ankle pain. We report three patients, one with acute fracture and two with chronic ankle symptoms. Technetium 99 methylene diphosphonate showed intense focal uptake at the posterior talus pointing to the os trigonum as the site of symptoms. It was excised in two patients with complete relief. The third went on to develop an asymptomatic nonunion. We recommend bone scanning as a procedure that is helpful in delineating obscure pain in the ankle that may be due to chronic irritative nonunion of the os trigonum

  9. The role of laboratory animals in studying bone cancer resulting from skeletally deposited radionuclides

    International Nuclear Information System (INIS)

    Boecker, B.B.; Miller, S.C.; Lloyd, R.D.; Taylor, G.N.; Griffith, W.C.; Guilmette, R.A.; Hahn, F.F.; Muggenburg, B.A.

    1994-01-01

    There is a continuing need to determine and understand the long-term health risks of internally deposited radionuclides in persons exposed medically or occupationally, or from radionuclides in the environment. A full understanding of these health risks, particularly for exposures involving low doses and dose rates, requires in-depth knowledge of both the dosimetry of a given exposure and the resulting long-term biological effects. Human data on 224 Ra and 226,228 Ra and their decay products are our primary sources of knowledge on the health risks of chronic alpha irradiation of the skeleton and serve as essential segments of our radiation protection practices for internally deposited radionuclides. However, we cannot obtain all of the needed information from these studies. This paper examines the role of laboratory animal studies in complementing and extending the knowledge of radiation-induced bone cancer obtained from studies of humans exposed to 224 Ra or 226,228 Ra

  10. The diagnostic value of monoclonal antibody scan (leucoscan) compared with 99mTc MDP bone scan and Ga 67 in diagnosing bone and joint infection

    International Nuclear Information System (INIS)

    Koukouraki, S.I.; Velidaki, A.; Prassopoulos, V.; Karkavitsas, N.; Vavouranakis, H.; Hatjipavlou, A.

    2002-01-01

    Full text: Nowadays different radiopharmaceuticals have been developed as 99mTc MDP, 67Ga citrate, 111In oxine- and 99mTc HMPAO labeled leucocytes for the accurate localization of bone/joint infection, but all of them have limitations that encouraged the search of new agents characterized from high and early uptake in infectious/inflammatory tissues, low toxicity and no accumulation in non inflamed tissues. The purpose of this study is to compare the diagnostic value of a 99mTc labeled antigranulocyte Fab' fragment (Leucoscan) with 99mTc MDP bone scan and 67 Ga. The monoclonal antibody, Leucoscan, is an IgG murine Fab' fragment directed against a NCA-90 epitope located on the surface of granulocytes. 45 patients with suspected bone and joint infection (18 total hip prosthesis, 4 knee prosthesis, 8 vertebral infection and 15 long bones) were included in this study. All patients underwent conventional Rx, bone scan, 67Ga scan and Leucoscan. Three phase 99mTc MDP bone scan and 67Ga scan were performed using standard procedures. For Leucoscan the antibody was labeled with 25 mCi of 99mTc and was infected intravenously over 30 seconds. Ten minutes planar images were taken 1 h and 2 hrs p.i using a GE Millennium γ camera provided with a LEGP collimator. Images were evaluated as score 1 (no abnormal uptake), score 2 (probably positive), score 3 (definitely infected) according the intensity of abnormally increased uptake. Results were compared with 99mTc MDP bone scan and 67Ga scans. The final diagnosis was given by the surgical verification with histopathology or culture. All 45 patients had pathologic proof of presence/absence of bone and joint infection. 36/45 were positive for bone or joint infection and 9/45 were negative.30/36 patients with surgically proven bone and joint infection had true positive Leucoscan, 26/36 had true positive MDP bone scan and 20/36 true positive 67Ga scan. Nine out of 9 patients with proven absence of inflammation had true negative

  11. The value of whole-body bone scan combined with SPECT/CT in diagnosing benign and malignant vertebral fractures

    International Nuclear Information System (INIS)

    Xu Feng; Ma Yubo; Yuan Qi

    2012-01-01

    Objective: To evaluate the value of whole-body bone scan (WBS) combined with SPECT/CT in diagnosing of benign and malignant vertebral fractures. Methods: WBS and SPECT/CT data of 52 cases with vertebral fractures were reviewed and analyzed retrospectively, and the differences between the benign and malignant vertebral fractures were compared. Results: WBS found 78.8% (41/52) patients had lesions in the bones besides the spine, but the benign group was less in number. SPECT/CT found that malignant group was more likely to have bone destructions or pedicle radionuclide uptake than the benign group.Both of them had no radioactivity concentration in the tuberculosis or hyperparathyroidism. Conclusion: Although it still had some limitations,WBS combined with SPECT/CT is valuable in the diagnosis of benign and malignant vertebral fractures. (authors)

  12. Prospective evaluation of radionuclide scanning in detection of intestinal necrosis in neonatal necrotizing enterocolitis

    International Nuclear Information System (INIS)

    Haase, G.M.; Sfakianakis, G.N.; Lobe, T.E.; Boles, E.T.

    1981-01-01

    The ability of external imaging to demonstrate intestinal infarction in neonatal necrotizing enterocolitis (NEC) was prospectively evaluated. The radiopharmaceutical technetium--99m diphosphonate was injected intravenously and the patients subsequently underwent abdominal scanning. Clinical patient care and interpretation of the images were entirely independent throughout the study. Of 33 studies, 7 were positive, 4 were suspicious, and 22 were negative. One false positive study detected ischemia without transmural infarction. The second false positive scan occurred postoperatively and was due to misinterpretation of the hyperactivity along the surgical incision. None of the suspicious cases had damaged bowel. The two false negative studies clearly failed to demonstrate frank intestinal necrosis. The presence of very small areas of infarction, errors in technical settings, subjective interpretation of scans and delayed clearance of the radionuclide in a critically ill neonate may all limit the accuracy of external abdominal scanning. However, in spite of an error rate of 12%, it is likely that this technique will enhance the present clinical, laboratory, and radiologic parameters of patient management in NEC

  13. X-ray and radionuclide investigations of the bones and joints in psoriasis

    International Nuclear Information System (INIS)

    Spuzyak, M.I.; Vasil'ev, A.A.; Belyaev, G.M.; Vikman, Ya.Eh.

    1990-01-01

    Radiography of the bones and joints was performed in 133 psoriatic patients; osteoscintigraphy with 99m Tc-phosphate compounds was also performed in 42 of them. On the basis of x-ray findings 3 types of osteoarticular psoriasis were singled out: psoriatic polyarthritis, psoriatic polyarthrosis and psoriatic arthropathy. The most ample information on the type, activity and spreading of a pathological process in the bones and joints in psoriasis can be obtained from the combination of the x-ray and radionuclide methods

  14. Orthogonal views improves localisation in bone scans of wrist

    International Nuclear Information System (INIS)

    Roth, A.L.

    1997-01-01

    Full text: Of all nuclear medicine studies, bone scans are the most fundamental. However, straightforward these may seem, there are always mechanisms that can be implemented which assist in a more precise diagnosis, particularly in areas with an intricate bone structure. An 18-year-old right-handed student presented to her doctor with a one month history of pain over the right distal radio-ulna joint area. Clinically, she had prominence of the right ulna, which suggested that there may have been a previous injury to the wrist. Also, pronation/supination were painful where there was swelling of the extensor carpi ulnaris tendon, as well as some discomfort with clicking in ulna deviation/rotation. The X-rays demonstrated some premature radial epiphysial closure. A bone scan was requested to attempt to localise the main inflammatory focus. The dynamic study was performed in the planar projection with an immediate blood pool for 300k being taken. These demonstrated a vascular blush medially. A medial blood pool image was acquired and it localised the abnormal vascularity as being dorsal. A separate focal area of less intense blood pooling was also noted in the line of the distal ulna. Delayed images showed increased uptake localised to the ulna styloid. Anatomically, the superficial vascular blush correlated with tenosynovitis. Hence, the orthogonal initial and delayed images were definitive in the diagnoses of tenosynovitis of the extensor carpi ulnaris tendon. This clearly complements the information provided by the palmar view. However, it is important to remember that an increased radiation dose to the technologist is incurred as a result of the extra orthogonal view, hence attention to technique is imperative

  15. Orthogonal views improves localisation in bone scans of wrist

    Energy Technology Data Exchange (ETDEWEB)

    Roth, A.L.

    1997-09-01

    Full text: Of all nuclear medicine studies, bone scans are the most fundamental. However, straightforward these may seem, there are always mechanisms that can be implemented which assist in a more precise diagnosis, particularly in areas with an intricate bone structure. An 18-year-old right-handed student presented to her doctor with a one month history of pain over the right distal radio-ulna joint area. Clinically, she had prominence of the right ulna, which suggested that there may have been a previous injury to the wrist. Also, pronation/supination were painful where there was swelling of the extensor carpi ulnaris tendon, as well as some discomfort with clicking in ulna deviation/rotation. The X-rays demonstrated some premature radial epiphysial closure. A bone scan was requested to attempt to localise the main inflammatory focus. The dynamic study was performed in the planar projection with an immediate blood pool for 300k being taken. These demonstrated a vascular blush medially. A medial blood pool image was acquired and it localised the abnormal vascularity as being dorsal. A separate focal area of less intense blood pooling was also noted in the line of the distal ulna. Delayed images showed increased uptake localised to the ulna styloid. Anatomically, the superficial vascular blush correlated with tenosynovitis. Hence, the orthogonal initial and delayed images were definitive in the diagnoses of tenosynovitis of the extensor carpi ulnaris tendon. This clearly complements the information provided by the palmar view. However, it is important to remember that an increased radiation dose to the technologist is incurred as a result of the extra orthogonal view, hence attention to technique is imperative.

  16. Unsuspected costo-vertebral fractures demonstrated by bone scanning in the child abuse syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F W; Gilday, D L; Ash, J M; Green, M D

    1980-01-01

    Many patterns of injury have been described in the child abuse syndrome. Until recently, all the bone manifestations of this syndrome have been diagnosed radiologically. Four cases of multiple costovertebral fracture diagnosed by bone scan are described and their etiology discussed. The use of bone scanning in identifying fractures which previously would have been missed is advocated.

  17. Unsuspected costo-vertebral fractures demonstrated by bone scanning in the child abuse syndrome

    International Nuclear Information System (INIS)

    Smith, F.W.; Gilday, D.L.; Ash, J.M.; Green, M.D.

    1980-01-01

    Many patterns of injury have been described in the child abuse syndrome. Until recently, all the bone manifestations of this syndrome have been diagnosed radiologically. Four cases of multiple costovertebral fracture diagnosed by bone scan are described and their etiology discussed. The use of bone scanning in identifying fractures which previously would have been missed is advocated. (orig.) [de

  18. Bone scanning with technetium /sup 99m/Tc polyphosphate in tuberculous osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Fanning, A; Dierich, H; Lentle, B

    1974-09-01

    Bone scans in 7 patients with tuberculosis have indicated bony involvement in 3. This was unsuspected in 2 and in all 3 radiographic correlation has been obtained. The present ready availability of more modern bone scanning agents and their safety is important to remember. They provide an elegant and sensitive, if non-specific, index of bone disease.

  19. Numeric scintigraphy in the exploration of bone metastases. About 619 patients, 819 scans and 97 biopsy

    International Nuclear Information System (INIS)

    Robillard, J.; Couette, J.E.; Ly Van Hoa; Chedeville, R.; Mandard, A.M.; Chasles, J.

    1977-01-01

    Histograms which show uptake rate distribution on bone metastases and on normal bones, arthrosic bone, uncalcified bone, have been drawn up. 819 scans performed on 627 patients have been classified according to ratio of bone segment/knee, bone segment/whole body and bone segment/minimum (knee, whole body). Henry's straight lines have been drawn in man and in woman for these different ratios in order to select the best discriminant. At last a biopsy on 97 patients has controlled the validity of the method. Quantitative scanning allows, on the other hand, to observe the evaluation of metastases under treatment as shown by the fixation curves during this time [fr

  20. Comparison of bone tumors induced by beta-emitting or alpha-emitting radionuclides: Schemes of pathogenesis

    International Nuclear Information System (INIS)

    Gillett, N.A.; Muggenburg, B.A.; Pool, R.R.; Hahn, F.F.

    1988-01-01

    Life-span studies in Beagle dogs have documented the occurrence of bone tumors following exposure to bone-seeking alpha- or beta-emitting radionuclides administered by different routes of exposure. Bone tumors from dogs in four different life-span studies were analyzed according to tumor phenotype, tumor location, radiographic appearance, incidence of metastasis, and association with radiation osteodystrophy. Marked differences in these parameters were observed that did not correlate with differences in radionuclide type, route of exposure, or duration of radionuclide uptake. Radiation osteodystrophy, which is postulated to be a preneoplastic lesion, was not a significant component in one of the studies. Analysis of the data from these four studies suggests that at least two different mechanisms of bone tumor pathogenesis occur for radiation-induced bone tumors. (author)

  1. Analytical sensitivity of Tc99m radionuclide 'milk' scanning in the detection of gastro-oesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Paton, J.Y.; Nanayakkara, C.S.; Cosgriff, P.S.

    1985-09-01

    The analytical sensitivity of radionuclide ''milk'' scans for detecting gastro-oesophageal reflux (GOR) has been assessed using an in vitro simulation test. Five factors were found to affect the ability to detect simulated reflux: isotope concentration, absolute gamma camera sensitivity, absorber thickness overlying the ''oesophagus'' and volume and duration of reflux. We found that a critical volume-duration product must be exceeded for reflux to be detected. Radionuclide milk scanning appears to be much less sensitive in detecting transient events like GOR than might be expected from previously reported static simulation studies.

  2. Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

    Energy Technology Data Exchange (ETDEWEB)

    Falchook, Aaron D. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Salloum, Ramzi G. [Department of Health Services Policy and Management, University of South Carolina, Columbia, South Carolina (United States); Hendrix, Laura H. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Chen, Ronald C., E-mail: ronald_chen@med.unc.edu [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Cecil G. Sheps Center for Health Services Research, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States)

    2014-06-01

    Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

  3. A reappraisal of serial isotope bone scans in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    O' Donoghue, J M; Rogers, E; Grimes, H; McCarthy, P; Corcoran, M; Bredin, H; Given, H F [University College Hospital, Galway (Ireland)

    1993-08-01

    The authors have evaluated prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) as alternatives to conventional serial bone scanning in 129 patients with newly diagnosed prostate cancer over a period of 3 years. Although serum PSA did not reflect local tumour burden at presentation, it was significantly elevated in those with stage D disease (p < 0.01). 45 patients presented de novo with metastatic bone deposits and a further 18 patients developed metastases during the study. The sensitivity of PSA in detecting secondary deposits at presentation for levels in excess of 100 [mu]g/l was 93.75%, the positive predictive value 95.7% and the negative predictive value for levels less than 5 [mu]g/l was 90.6%. During the follow-up period sensitivity was 94.4%, the positive predictive value 100%, the negative predictive value 100%, with a median lead time of 3 months in predicting metastases in the 18 patients with progressive disease. (author).

  4. An incidental finding of myocardial uptake on HDP bone scan

    International Nuclear Information System (INIS)

    Smith, T.

    1998-01-01

    Full text: A 75 year old male referred with a history of wrist pain for a HDP bone scan(700Mbq) had dynamic and blood pool images. A posterior sweep and planar images were performed after 2 hours. The scan demonstrated a fracture of the left radial styloid, other degenerative arthritis and diffuse tracer uptake throughout the myocardium. The differential diagnoses included cardiac amyloid, myocardial infarction (MI) and calcific pericarditis. The patient, a non insulin dependent diabetic with previous MI in 1978 and hypertension had nocturnal dyspnoea and no chest pain. Chest X-ray was normal. ECG revealed old inferior infarct. Echocardiography showed mild hypokinesis of the inferior wall, low normal LV contractility, normal pericardium and no evidence of amyloid. A Rest (400Mbq) / Stress(1200Mbq) Sestamibi(MIBI) was performed to assess status of ischaemic heart disease (IHD). The patient experienced leg fatigue and shortness of breath but no chest pain. Rest ECG showed sinus bradycardia with ST/T wave changes. Stress ECG showed ST segment depression (0.5mm). Planar and SPECT studies showed reversible perfusion defects in the anterior wall and apex with a fixed inferolateral defect. Gated SPECT showed normal wall motion apart from the inferolateral infarct. The exact cause of the HDP uptake in the myocardium is unknown. The echo findings exclude amyloid or pericarditis. The MIBI study confirmed a small inferolateral infarct and myocardial ischaemia in the anterior wall and apex. The scan has affected patient management by diagnosing a fracture of the radial styloid and confirming previous infarction and myocardial ischaemia. An open view must be taken of the cardiac HDP uptake. The most likely diagnosis in this patient is silent IHD, which has been demonstrated in one other case known to us

  5. Use of bone and brain scans as screening procedures in patients with malignant lesions

    International Nuclear Information System (INIS)

    Felix, E.L.; Sindelar, W.F.; Bagley, D.H.; Johnston, G.S.; Ketcham, A.S.

    1975-01-01

    A retrospective study to determine the value of bone and brain scans was performed in preoperative patients with melanoma, sarcoma, cancer of the head and neck and carcinoma of the pelvis. No occult metastases were identified in 170 patients in whom brain scan was performed. On late follow-up data, eight patients had neurologic symptoms develop and had brain metastases identified on scan. Of 223 bone scans performed, only one distant metastatic lesion was identified. It is, therefore, suggested that, in these types of patients, bone and brain scans be reserved for those with symptoms referable to the neurologic or skeletal systems

  6. Survey of bone pain in patients of infectious section of Labafinejad hospital using radioisotope scanning

    International Nuclear Information System (INIS)

    Ibrahimie, Farhad

    1996-01-01

    Skeletal scintigraphy is the first or second most frequently performed imaging procedure in most nuclear medicine departments. The uses of bone scan in orthopedic practice are multiple. Bone scans are often used to localize disease, to identify areas of focal increased physiological activity, and to evaluate pain. Bone scans are particularly useful in depicting and localizing small tumors. Bone scans may clarify the significance of radiographic abnormalities. When pain is poorly localized, a bone scan helps focus attention, particularly when it precisely corresponds to the questionable radiographic lesion. In order to do a survey about role of bone scan for the detection and localizing bone pain, a retrospective study was done about 37 patient who from 1373 to 1374 were admitted to the infectious department of Martyr Labafinejad having bone pain. The results of our studies showed that most common case of bone pain of this patients was due to brucellosis (brucella arthritis) with 19%, and other causes were cellulits with 13.15% osteomyelitis and D.J.D with 11%, septic arthritis, bone metastasis, bone abscesses, discopathy, infectious spondylitis, lymphoma, D.V.T. and reactive traumatic arthritis with 2.7%

  7. Should single-phase radionuclide bone imaging be used in suspected osteomyelitis

    International Nuclear Information System (INIS)

    Fihn, S.D.; Larson, E.B.; Nelp, W.B.; Rudd, T.G.; Gerber, F.H.

    1984-01-01

    The records of 69 patients who had 86 delayed, static radionuclide bone images for suspected osteomyelitis were studied to determine the effects of this procedure on diagnosis and treatment. Sensitivity, specificity, and positive predictive value were lower than reported in several other studies. When osteomyelitis was unlikely, imaging was either negative or falsely positive and rarely affected treatment. In 46 cases where osteomyelitis was more likely, imaging potentially changed therapy in 19 but was unhelpful or misleading in 15. Static-phase images with ''definite'' interpretations, particularly when negative, are specific, but ''equivocal'' studies may lead to diagnostic and therapeutic errors. When ostemyelitis is improbable, imaging rarely changes diagnosis or therapy

  8. Growth plate closure: Apex view on bone scan

    International Nuclear Information System (INIS)

    Giles, P.H.; Trochei, M.; Yeates, K.

    1984-01-01

    Angular deformities of the extremities in children following premature closure of the growth plate are well known. The deformities depend on the position of an osseus bridge which forms between the epiphysis and metaphysis. Several surgical procedures including resection of the osseus bridge have been described, however, delineation of the site of fusion is difficult to define. The commonest site of growth plate arrest is the distal femoral or proximal tibial growth plate. A new technique using the bone scan has been developed which accurately defines the area and position of these osseus bridges. Two hours after injection of technetium 99m methylene diphosphonate apex views of the affected distal femoral growth plate were performed. The knee was flexed into its smallest angle. Using a pinhole collimator the gamma camera was angled to face the affected growth plate end on. The image was collected onto computer and analysed by: (I) regions of interest over segments of the growth plate to calculate the relative area of total growth plate affected: (II) generating histograms: (III) thresholding or performing isocontours to accentuate abnormal areas. The growth plate is normally uniformly increased when compared to the normal shaft of the bone. Fusion across the plate appears as an area of diminished uptake. The apex view gives a unique functional map of the growth plate such that abnormal areas are displayed, and the site, size and position of osseus fusion obtained. The technique has the potential for determining the metabolic activity of the growth plate before and after surgery. Serial studies will allow assessment of regneration of the plate and reformation of new osseus bridges

  9. Critical assessment of bone scan quantitation (bone to soft tissue ratios) in the diagnosis of metabolic bone disease

    Energy Technology Data Exchange (ETDEWEB)

    Fogelman, I.; Gordon, D.; Bessent, R.G.

    1981-03-01

    Accurate quantitation from the bone scan image of skeletal uptake of radiopharmaceutical would be of value in the assessment of patients with metabolic bone disease. Repeat measurements of bone to soft tissue (B/ST) ratios on the one set of images were made for 103 subjects, a) by the same observer using lumbar vertebra 2 for the area of bone; b) by the same observer using lumbar vertebra 2 then lumbar vertebra 4; c) by two observers both using lumbar vertebra 2. The median difference between repeat measurements by the same observer was well under 1% but the 5-95 percentile range was -13 to +14%. Between the two observers there was a median difference of 10.6% with a 5-95 percentile range of -11 to +44%. We also measured B/ST ratios in 150 control subjects and 139 patients with various metabolic bone disorders. While statistically significant differences for B/ST ratios were found between the osteomalacia, renal osteodystrophy, Paget's groups, and the control population (P < 0.001 in all cases), there was appreciable overlap between individual patient results and the control range. It is concluded, therefore, that measurement of B/ST ratios for the individual is of limited value in clinical practice.

  10. Childhood acute lymphoblastic leukemia presenting as ''cold'' lesions on bone scan: a report of two cases

    International Nuclear Information System (INIS)

    Caudle, R.J.; Crawford, A.H.; Gelfand, M.J.; Gruppo, R.A.

    1987-01-01

    ''Cold'' lesions on bone scan have been reported in a variety of disease processes, including infection, avascular necrosis, and cysts. We present two cases of children who presented with large ''cold'' areas on technetium bone scans and were treated initially for septic processes. Acute childhood leukemia frequently presents with bone or joint pain, fever, and elevation of the erythrocyte sedimentation rate. Although the diagnosis may be difficult if the characteristic clinical signs and laboratory findings are absent, the presence of anemia should alert the physician to the possibility of malignancy. Bone scanning provides a sensitive method of localizing pathology, but diagnosis requires biopsy or marrow aspiration

  11. Bone scan in breast cancer patients with mastectomy and breast reconstruction with a myocutaneous TRAM flap

    International Nuclear Information System (INIS)

    Morales, Rosanna; Cano, Roque; Delgado, Ricardo; Munive, Carlos

    2014-01-01

    Objectives: To report findings in bone scans for breast cancer patients with mastectomy and breast reconstruction with transverse rectus abdominis myocutaneous flap (TRAM). Material and Methods: Inclusion criteria were: confirmed breast cancer, mastectomy, breast reconstruction with TRAM flap and bone scan performed after TRAM. Exclusion criteria were: Absence of bone scan image, breast reconstruction by other approaches. Results: Absence of uptake in TRAM flap in six patients, diminished uptake in skin near TRAM, with peripheral increased uptake in three and increased uptake in TRAM flap, in a patient with cancer recurrence, confirmed by biopsy. Conclusions: Bone scans in breast cancer patients with mastectomy and TRAM flap can have different imaging presentations, procedure details diminish reporting errors. TRAM flap may present fat necrosis areas, which should be differentiated from recurrence in bone scans. Additional imaging and biopsy will be needed to diagnose this finding. (authors).

  12. A case of marked colonic uptake on a bone scan

    International Nuclear Information System (INIS)

    Roberts, J.M.; Mansberg, R.; Uren, R.F.; Howman-Giles, R.

    2003-01-01

    Full text: A 53-year-old man was referred for a bone scan to evaluate right hip pain. Delayed images revealed increased osteoblastic activity in the right sacro-iliac joint consistent with trauma or inflammation. In addition the ascending and transverse colon were well visualised. The uptake in the tomographic images throughout the ascending and transverse colon was so prominent that the haustrations were clearly visualised confirming intraluminal activity. No obvious pathology was evident but review of the images by one of the authors (RFU) revealed that the patient had a myocardial perfusion study using Tc-99m Sestamibi the previous day at a different practice and referred by another medical practitioner. This case illustrates an example of the unusual scintigraphic images that may result in patients referred for various studies at different practices by multiple practitioners. Reporting physicians must remain vigilant to the possibility of a study being contaminated by isotopes from previous studies. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  13. Positive indium-III bone marrow scan in metastatic breast carcinoma. Case report

    International Nuclear Information System (INIS)

    LaManna, M.M.; Hyzinski, M.; Swami, V.K.; Parker, J.A.

    1984-01-01

    Indium is generally presumed to localize in the bone marrow within the erythroid cell line. Fibrosis, inflammation, lymphoma, extended field radiation, chemotherapy, or combinations of both treatment modalities generally depress the uptake of indium by the marrow in a complex fashion. We report a case of metastatic breast carcinoma and pancytopenia in which the In-111 scan appeared qualitatively similar to a Tc-99m MDP bone scan. Findings were confirmed by bone marrow biopsy

  14. Design and application of Mark IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1977-01-01

    The MARK IV system was built in our laboratory to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as 99 Tcsup(m), but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a four-sided arrangement of 32 independent detectors which continuously rotate as a unit, detecting, processing and displaying the reconstructed data while the study progresses. During the scanning procedure, accumulated data are transferred to a digital computer for reconstruction processing. Data are corrected to equalize detector response and compensate for photon attenuation in the head. This program requires 30 seconds for completion, whereupon the final reconstruction, a 64 x 64 matrix from the single revolution, outputs to a core store and is displayed on the screen of a cathode-ray tube. As the rotation sequence continues, new data from each revolution are added to previous data and reprocessed for a new picture. Since the instrument operates at 50 s per revolution, the continuous collection and processing of data causes a new picture to appear on the display every 50 s as the study progresses. The operator may extend or curtail the duration of the examination according to the appearance of the picture. In practice, a five revolution (4.2 min.) scan is commonly used in most clinical studies. The instrument is a high sensitivity device with approximately uniform resolution (1.7 cm FWHM) throughout the section plane. Quantification of concentration of radioactivity in small regions is accurate and reproducible. The instrument has been applied to the study of alterations in cerebral vascular permeability, blood flow and blood volume, and to the study of cerebral glucose metabolism and cerebral spinal fluid distribution. (author)

  15. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  16. Bone metastases from breast cancer at the time or radical mastectomy as detected by bone scan. Eight-year follow-up.

    Science.gov (United States)

    Sklaroff, R B; Sklaroff, D M

    1976-07-01

    Sixty-four women with Stage II breast cancer who had Sr85 bone scans at the time of radical mastectomy were followed for 8 years in a prospective study. Those women with positive scans had a slight, but statistically significant, increased incidence of metastic disease, particularly for metastases to bone.However, 40% of those women with positive bone scans and negative roentgenograms survived 8 years without evidence of any metastatic disease. Therefore, it has not been shown at this time that bone scans should be obtained in order to exclude bone metastasis before regional therapy for breast cancer is instituted. Also, a significant percentage of women with negative bone scans developed both bone and soft tissue metastases. As many as 30% of asymptomatic women with a history of breast cancer and positive bone scans and negative bone roentgenograms may still harbor disease in bone after 8 years.

  17. Improved radionuclide method for the diagnosis of gastroesophageal reflux and aspiration in children (milk scan)

    International Nuclear Information System (INIS)

    Heyman, S.; Kirkpatrick, J.A.; Winter, H.S.; Treves, S.

    1979-01-01

    A radionuclide study using technetium-99m-labelled milk feeding is described for the detection of gastroesophageal reflux and aspiration in children. A comparison of findings in 39 patients referred for both radiographic and radionuclide studies showed that barium studies were positive in 25.6% and radionuclide studies in 59% of cases, reflecting the sensitivity of the radionuclide technique. This technique is also physiological and allows prolonged patient monitoring. It is simple to perform and should prove useful in the evaluation of patients suspected of having gastroesophageal reflux and aspiration

  18. Muscular injury in a child diagnosed by 99mTc-MDP bone scan

    International Nuclear Information System (INIS)

    Tondeur, M.; Piepsz, A.; Ham, H.R.; Haentjens, M.

    1989-01-01

    An 11-year-old boy had bone scanning to rule out an osseous lesion of the right arm. He presented progressive pain and hard swelling of the right arm. His past medical history and general physical examination were unremarkable. He trained for karate. The scan demonstrated considerable muscular uptake in both arms. CKP and CKP MB levels were both abnormally high, suggesting muscle injury. After a 10-day rest period the bone scan returned to normal. (orig.)

  19. Muscular injury in a child diagnosed by /sup 99m/Tc-MDP bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Tondeur, M.; Piepsz, A.; Ham, H.R.; Haentjens, M.

    1989-06-01

    An 11-year-old boy had bone scanning to rule out an osseous lesion of the right arm. He presented progressive pain and hard swelling of the right arm. His past medical history and general physical examination were unremarkable. He trained for karate. The scan demonstrated considerable muscular uptake in both arms. CKP and CKP MB levels were both abnormally high, suggesting muscle injury. After a 10-day rest period the bone scan returned to normal.

  20. The influence of volatile anesthetics on alveolar epithelial permeability measured by noninvasive radionuclide lung scan

    International Nuclear Information System (INIS)

    Hung, Chih-Jen; Wu, Rick Sai-Chuen; Lin, Cheng-Chieh; Kao, Albert; Tsai, Jeffrey J.P.

    2003-01-01

    Many volatile anesthetics have long been thought to affect pulmonary functions including lung ventilation (LV) and alveolar epithelial permeability (AEP). The purpose of this study is to examine the influence of volatile anesthetics on LV and AEP by noninvasive radionuclide lung imaging of technetium-99m labeled diethylene triamine pentaacetic acid radioaerosol inhalation lung scan (DTPA lung scan). Twenty patients undergoing surgery and receiving volatile anesthesia with 1% halothane were enrolled as the study group 1. The other 20 patients undergoing surgery and receiving volatile anesthesia with 1.5% isoflurane were enrolled as the study group 2. At the same time, 20 patients undergoing surgery with intravenous anesthesia drugs were included as a control group. Before surgery, 1 hour after surgery, and 1 week after surgery, we investigated the 3 groups of patients with DTPA lung scan to evaluate LV and AEP by 99m Tc DTPA clearance halftime (T1/2). No significant change or abnormality of LV before surgery, 1 hour after surgery, or 1 week after surgery was found among the 3 groups of patients. In the control group, the 99m Tc DTPA clearance T1/2 was 63.5±16.4, 63.1±18.4, and 62.8±17.0 minutes, before surgery, 1 hour after surgery, and 1 week after surgery, respectively. In group 1, it was 65.9±9.3, 62.5±9.1, and 65.8±10.3 minutes, respectively. No significant change in AEP before surgery, 1 hour after surgery, or 1 week after surgery was found. However, in group 2, the 99m Tc DTPA clearance T1/2 was 65.5±13.2, 44.9±10.5, and 66.1±14.0 minutes, respectively. A significant transient change in AEP was found 1 hour after surgery, but it recovered 1 week after surgery. We conclude that volatile anesthesia is safe for LV and AEP, and only isoflurane can induce transient change of AEP. (author)

  1. A Case of with Transient splenic Hot Uptake on {sup 99m}Tc-Methylene Diphosphonate (MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Hyeon; Kim, Jae Myung; Kim, Jung Han; Choo, Gil Yeon; Park, Seok Oh; Sung, Sang Kyu; Choi, Dae Seob; Kim, Chin Seung [Sung Ae General Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hemoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, {sup 99m}Tc-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on {sup 99m}Tc Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  2. A Case of with Transient splenic Hot Uptake on 99mTc-Methylene Diphosphonate (MDP) Bone Scan Following Blunt Abodominal Trauma with Underlying Liver Cirrhosis

    International Nuclear Information System (INIS)

    Won, Jong Hyeon; Kim, Jae Myung; Kim, Jung Han; Choo, Gil Yeon; Park, Seok Oh; Sung, Sang Kyu; Choi, Dae Seob; Kim, Chin Seung

    1993-01-01

    We report a case of 33-year-old man with a transient splenic uptake who had traumatic multiple rib fractures and hemoperitoneum combined with underlying liver cirrhosis, liver cirrhosis with liver bed laceration and splenomegaly without any other demonstrable splenic lesion due to traffic accident was found by abdominal ultrasound and surgery. Incidentally, 99m Tc-MDP Bone scan showed whole prominent splenic uptake, spleen was also visible on 99m Tc Tin colloid liver scan. We suggest the splenic uptake of the radionuclide temporary splenic infarct to the transient total splenic infarction or unknown traumatic effect.

  3. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    International Nuclear Information System (INIS)

    Sundberg, S.B.; Savage, J.P.; Foster, B.K.

    1989-01-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis

  4. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration

    International Nuclear Information System (INIS)

    Heslinga, J.M.; Pauwels, E.K.J.; Zwaveling, A.

    1982-01-01

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period. (Auth.)

  5. Whole Body Bone Scan Findings after High Intensity Focused Ultrasound (HIFU) Treatment

    International Nuclear Information System (INIS)

    Seo, Ye Young; O, Joo Hyun; Sohn, Hyung Sun; Choi, Eun Kyoung; Yoo, Ik Dong; Oh, Jin Kyoung; Han, Eun Ji; Jung, Seung Eun; Kim, Sung Hoon

    2011-01-01

    This study aims to examine the findings of 99mT c diphosphonate bone scans in cancer patients with a history of HIFU treatment. Bone scan images of patients with a history of HIFU treatment for primary of metastatic cancer from January 2006 to July 2010 were retrospectively reviewed. Cases of primary bone tumor or HIFU treatment reaching only the superficial soft tissue layer were excluded. Bone scan images of 62 patients (26 female, 36 male; mean age 57±9 years) were studied. HIFU treatment was performed in the liver (n=40), pancreas (n=40), pancreas (n=16), and breast (n=6). Mean interval time between HIFU treatment and bone scan was 106±105 days (range: 1-572 days). Of 62 scans, 43 showed diffusely decreased uptake of bone within the path of HIFU treatment: antero axillary and/or posterior arcs of right 5th to 11th ribs in 34 cases after treatment of hepatic lesions; anterior arcs of 2nd to 5th ribs in 5 cases after treatment for breast tumors; and posterior arcs of left 9th to 11th ribs or thoraco lumbar vertebrae in 4 cases after treatment for pancreas tumor. Of 20 patients who had bone scans more than twice, five showed recovered uptake of the radiotracer in the involved ribs in the follow up bone scan. Of 62 bone scans in patients with a history of HIFU treatment for primary of metastatic cancer, 69% presented diffusely decreased uptake in the bone in the path of HIFU treatment.

  6. Bone scan as a screening test for missed fractures in severely injured patients.

    Science.gov (United States)

    Lee, K-J; Jung, K; Kim, J; Kwon, J

    2014-12-01

    In many cases, patients with severe blunt trauma have multiple fractures throughout the body. These fractures are not often detectable by history or physical examination, and their diagnosis can be delayed or even missed. Thus, screening test fractures of the whole body is required after initial management. We performed this study to evaluate the reliability of bone scans for detecting missed fractures in patients with multiple severe traumas and we analyzed the causes of missed fractures by using bone scan. A bone scan is useful as a screening test for fractures of the entire body of severe trauma patients who are passed the acute phase. We reviewed the electronic medical records of severe trauma patients who underwent a bone scan from September 2009 to December 2010. Demographic and medical data were compared and statistically analyzed to determine whether missed fractures were detected after bone scan in the two groups. A total of 382 patients who had an injury severity score [ISS] greater than 16 points with multiple traumas visited the emergency room. One hundred and thirty-one patients underwent bone scan and 81 patients were identified with missed fractures by bone scan. The most frequent location for missed fractures was the rib area (55 cases, 41.98%), followed by the extremities (42 cases, 32.06%). The missed fractures that required surgery or splint were most common in extremities (11 cases). In univariate analysis, higher ISS scores and mechanism of injury were related with the probability that missed fractures would be found with a bone scan. The ISS score was statistically significant in multivariate analysis. Bone scan is an effective method of detecting missed fractures among patients with multiple severe traumas. Level IV, retrospective study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  7. Technetium-99m--pyrophosphate bone scans in hyperparathyroidism

    International Nuclear Information System (INIS)

    Wiegmann, T.; Rosenthall, L.; Kaye, M.

    1977-01-01

    Most patients with primary hyperparathyroidism have normal 5-hr bone-to-soft-tissue ratios for /sup 99m/Tc-pyrophosphate. In contrast, all five patients with advanced secondary hyperparathyroidism in this study showed significant (p less than 0.001) increases of bone uptake. In the early period after parathyroidectomy, there was no quantitative or qualitative change in uptake. A limited decrease of bone uptake was observed only after prolonged periods of observation. In itself, parathyroid activity seems to have little direct influence on bone uptake of /sup 99m/Tc-pyrophosphate

  8. Automated segmentation of tumors on bone scans using anatomy-specific thresholding

    Science.gov (United States)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Lu, Peiyun; Ramakrishna, Bharath; Gjertson, David; Poon, Cheryce; Auerbach, Martin; Goldin, Jonathan; Brown, Matthew S.

    2012-03-01

    Quantification of overall tumor area on bone scans may be a potential biomarker for treatment response assessment and has, to date, not been investigated. Segmentation of bone metastases on bone scans is a fundamental step for this response marker. In this paper, we propose a fully automated computerized method for the segmentation of bone metastases on bone scans, taking into account characteristics of different anatomic regions. A scan is first segmented into anatomic regions via an atlas-based segmentation procedure, which involves non-rigidly registering a labeled atlas scan to the patient scan. Next, an intensity normalization method is applied to account for varying levels of radiotracer dosing levels and scan timing. Lastly, lesions are segmented via anatomic regionspecific intensity thresholding. Thresholds are chosen by receiver operating characteristic (ROC) curve analysis against manual contouring by board certified nuclear medicine physicians. A leave-one-out cross validation of our method on a set of 39 bone scans with metastases marked by 2 board-certified nuclear medicine physicians yielded a median sensitivity of 95.5%, and specificity of 93.9%. Our method was compared with a global intensity thresholding method. The results show a comparable sensitivity and significantly improved overall specificity, with a p-value of 0.0069.

  9. Radionuclide investigation of the bone marrow with 99mTc-coren in patients with polycythemia vera

    International Nuclear Information System (INIS)

    Vasil'ev, L.Ya.; Prikhod'ko, A.G.; Rozdil'skij, S.I.; Astap'eva, O.N.; Grusha, A.V.

    1990-01-01

    The results of radionuclide investigation of the bone marrow in 44 patients (of them 32 with polycythemia vera) were presented. The informative value of bone marrow scintigraphy and whole-body radiometry using 99m Tc-coren was shown in the patients with polycythemia vera at advanced stages. The results obtained made it possible to specify a clinical stage and prognosis of disease, and to optimize therapy

  10. Role of nuclear medicine bone scans in evaluating pain in athletic injuries

    International Nuclear Information System (INIS)

    Martire, J.R.

    1987-01-01

    The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references

  11. Radionuclide bone imaging in the surgical treatment planning of odontogenic keratocysts

    Energy Technology Data Exchange (ETDEWEB)

    Lurie, A.G.; Puri, S.; James, R.B.; Warnich, J.T.

    1976-12-01

    Locally aggressive benign lesions of the jaws, such as odontogenic keratocysts and ameloblastomas, require complete excision in view of the high incidence of recurrence after incomplete surgical removal. Because of the limitations of conventional radiology as the sole technique for determining the extent of these lesions, the use of 99m-technetium-labeled bone-imaging agents is suggested. This method of defining the location of surgical margins is based on the agent's sensitivity as an indicator of subtle changes in bone metabolism. A case of an unusually large recurrent odontogenic keratocyst is presented in which the planning of the surgical procedure was predicated on the results of a bone scan of the jaws in addition to conventional radiology. This diagnostic procedure, especially when used in conjunction with conventional radiology, appears to be of considerable value in defining the extent of a variety of oral-maxillofacial bony lesions.

  12. Radionuclide bone imaging in the surgical treatment planning of odontogenic keratocysts

    International Nuclear Information System (INIS)

    Lurie, A.G.; Puri, S.; James, R.B.; Warnich, J.T.

    1976-01-01

    Locally aggressive benign lesions of the jaws, such as odontogenic keratocysts and ameloblastomas, require complete excision in view of the high incidence of recurrence after incomplete surgical removal. Because of the limitations of conventional radiology as the sole technique for determining the extent of these lesions, the use of 99m-technetium-labeled bone-imaging agents is suggested. This method of defining the location of surgical margins is based on the agent's sensitivity as an indicator of subtle changes in bone metabolism. A case of an unusually large recurrent odontogenic keratocyst is presented in which the planning of the surgical procedure was predicated on the results of a bone scan of the jaws in addition to conventional radiology. This diagnostic procedure, especially when used in conjunction with conventional radiology, appears to be of considerable value in defining the extent of a variety of oral-maxillofacial bony lesions

  13. Osteopetrosis: Radiological & Radionuclide Imaging

    International Nuclear Information System (INIS)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent 99m Tc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis

  14. Extraosseous radiotracer uptake on bone scan in beta-thalassemia: report of one case

    International Nuclear Information System (INIS)

    Guezguez, M.; Nouira, M.; Sfar, R.; Chatti, K.; Ben Fradj, M.; Ben Ali, K.; Ajmi, S.; Essabbah, H.; Zrour, S.

    2009-01-01

    Red blood cell transfusion, main therapeutic modality of beta-thalassemia, leads to iron overload which may perturb several metabolic ways. The aim of this paper is to illustrate the uptake abnormalities observed on bone scan of thalassaemic patients and to discuss mechanisms of extraosseous accumulation of the radiopharmaceutical in this pathology. We report a 16-year-old child suffering from beta-thalassemia major undergoing transfusion therapy. A bone scan was indicated to look for osseous infection. This study revealed a little skeletal uptake and abnormal liver, splenic and renal accumulation. A repeat bone scan, performed three weeks later showed a better skeletal uptake which enabled the discovery of focal abnormalities and made the diagnostic easier. The effect of iron overload on radiopharmaceuticals uptake in bone scan is known since 1975. Dissociation of 99m Tc from the carrier ligand due to the presence of iron excess seems the most plausible hypothesis. Free 99m Tc can be bound to other tissular substrates which can explain extraosseous uptake. The normally available pool for bone is reduced and then the skeletal uptake decreased. This report limits considerably the sensitivity of the bone scan. A well-led iron chelation and eventually the use of diuretic drug may guarantee a better quality of bone scan images. (authors)

  15. Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan

    International Nuclear Information System (INIS)

    Chatti, K.; Guezguez, M.; Maha Ben Fredj, M.; Sfar, R.; Essabbah, H.; Mtaoumi, M.; Chatti, K.

    2009-01-01

    Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal metastasis. Conclusion Ewing's sarcoma appears usually as an intense lesion on bone scan. Nevertheless, decreased radiopharmaceutical uptake or 'cold' lesion may be seen in aggressive Ewing's sarcoma with lytic tumor, growth of which is very rapid and bony reaction is minimal. (authors)

  16. Monte Carlo simulation of age-dependent radiation dose from alpha- and beta-emitting radionuclides to critical trabecular bone and bone marrow targets

    Science.gov (United States)

    Dant, James T.; Richardson, Richard B.; Nie, Linda H.

    2013-05-01

    Alpha (α) particles and low-energy beta (β) particles present minimal risk for external exposure. While these particles can induce leukemia and bone cancer due to internal exposure, they can also be beneficial for targeted radiation therapies. In this paper, a trabecular bone model is presented to investigate the radiation dose from bone- and marrow-seeking α and β emitters to different critical compartments (targets) of trabecular bone for different age groups. Two main issues are addressed with Monte Carlo simulations. The first is the absorption fractions (AFs) from bone and marrow to critical targets within the bone for different age groups. The other issue is the application of 223Ra for the radiotherapy treatment of bone metastases. Both a static model and a simulated bone remodeling process are established for trabecular bone. The results show significantly lower AFs from radionuclide sources in the bone volume to the peripheral marrow and the haematopoietic marrow for adults than for newborns and children. The AFs from sources on the bone surface and in the bone marrow to peripheral marrow and haematopoietic marrow also varies for adults and children depending on the energy of the particles. Regarding the use of 223Ra as a radionuclide for the radiotherapy of bone metastases, the simulations show a significantly higher dose from 223Ra and its progeny in forming bone to the target compartment of bone metastases than that from two other more commonly used β-emitting radiopharmaceuticals, 153Sm and 89Sr. There is also a slightly lower dose from 223Ra in forming bone to haematopoietic marrow than that from 153Sm and 89Sr. These results indicate a higher therapy efficiency and lower marrow toxicity from 223Ra and its progeny. In conclusion, age-related changes in bone dimension and cellularity seem to significantly affect the internal dose from α and β emitters in the bone and marrow to critical targets, and 223Ra may be a more efficient

  17. Two unusual causes of peripatellar nonmetastatic positive bone scans in patients with malignancies: case reports

    International Nuclear Information System (INIS)

    Turner, J.W.; Syed, I.B.; Spencer, R.P.

    1976-01-01

    Bone scans performed with /sup 99m/Tc-polyphosphate in two patients with epidermoid carcinoma of the lung each showed activity in one knee area. In the first case, radiographs of the area revealed Pellegrini-Stieda calcification over the internal femoral condyle. Uptake corresponded to this process, rather than to a lesion deep in the bone. In the second case, the activity accumulation in the right tibia was the only abnormality noted in the scan. An open biopsy revealed Paget's disease, and no radiographic evidence of Paget's disease was found in any other bone. These cases again illustrate that localized accumulation of a bone-scanning agent, in patients with known primary tumors, does not necessarily denote malignancy in bone

  18. Bone scanning a useful addition in the diagnosis of ankle joint trauma

    International Nuclear Information System (INIS)

    Schmidt, C.

    1983-01-01

    A retrospective study of the indication in 169 scintigraphic examinations of the ankle joint was made. Usually joints respond to trauma with a generalized increase of the concentration of the radiopharmaceutical. By using a highly performed technique the focal hot spot caused by the fracture can be seen in the bone scan. The focal accumulation of the radioactive material must not correspond to a bone fracture in any case. The ligamentous avulsion of a bone chip and/or the periosteum can yield the same image but it cannot be diagnosed by radiographic techniques. Initially the routine radiograph and even the tomograph often are interpreted as normal or equivocal. In these cases of ankle trauma bone scanning completes the clinical evaluation. Although bone scanning is very important in the diagnosis of any traumatic lesion of the ankle joints it cannot replace the conventional X-ray technique. (orig.) [de

  19. Radionuclide Imaging of Musculoskeletal Injuries in Athletes with Negative Radiographs.

    Science.gov (United States)

    Nagle, C E; Freitas, J E

    1987-06-01

    In brief: Radionuclide bone scans can be useful in the diagnostic evaluation of musculoskeletal injuries in athletes. Bone scans can detect shinsplints, stress fractures, and muscle injuries before they are detectable on radiographs. Prognosis can be accurately assessed, allowing appropriate treatment to proceed without delay. The authors discuss the use of bone scans and identify musculoskeletal injuries that are associated with specific sports, such as stress fracture of the femur (soccer), tibia (running), scapula (gymnastics), and pars interarticularis (football or lacrosse).

  20. Spinal chondrosarcoma demonstrated by Tc-99m-MDP bone scan

    International Nuclear Information System (INIS)

    Smith, F.W.; Nandi, S.C.; Mills, K.

    1982-01-01

    A case of chondrosarcoma of the spine in a 45-year-old woman is described. The bone scan performed after the intravenous injection of Tc-99m-MDP not only confirmed the solitary nature of the tumor, but also demonstrated its extent within the spinous process of the second dorsal vertebra. Preoperative bone scan in the management of chondrosarcoma is advocated as a safe, noninvasive technique for assessing the extent of the tumor

  1. Reversible bone pain and symmetric bone scan uptake in a dialysis patient treated with cinacalcet: a case report

    Directory of Open Access Journals (Sweden)

    Bottino Carla

    2010-06-01

    Full Text Available Abstract Introduction The medical management of secondary hyperparathyroidism in patients with end-stage renal disease involves a combination of dietary restrictions, phosphate binders, active vitamin D analogs, and calcimimetics. Case presentation We report the case of a 36-year-old Hispanic dialysis patient, originally from Cuba and now residing in the USA, who developed severe bone pain and muscle twitching after starting low dose cinacalcet, despite normal pre-dialysis ionized calcium and elevated parathyroid hormone. The clinical symptoms correlated with increased symmetrical uptake on bone scan that resolved rapidly upon discontinuation of cinacalcet. Conclusion Cinacalcet may induce severe bone pain and a unique bone scan uptake pattern in hemodialysis patients.

  2. The value of combined examination of serum CA15-3, CEA level and whole body bone scan in the diagnosis of bone metastasis in breast cancer

    International Nuclear Information System (INIS)

    Lu Baoshi; Gao Yufang

    2011-01-01

    Objective: To explore the value of combined examination of serum tumormarkers carbohydrate antigen 15-3 (CA15-3), carcinoembryonic antigen (CEA) and whole body bone scan in the diagnosis of bone metastasis in breast cancer. Methods: Whole body bone scan and serum CA15-3 and CEA levels with a electrochemical luminescence assay were performed in 97 patients with breast cancer (46 cases with bone metastasis and 51 cases without bone metastasis) and 45 patients with benign breast diseases. As for the negative cases who had significant pains in bones, CT or MRI was performed to make sure. Results: The serum level of CA15-3 and CEA were significantly higher in patients with bone metastasis than those in patients without bone metastasis and the benign lesions. The positive predicting values were 76.09% and 80.43%. Most patients with bone metastasis had positive results in bone scan (95.65%), only 2 cases had negative results (4.35%), which is positive by CT or MRI Seven. Seven patients without bone metastasis and Three patients with the benign lesions had positive results in bone scan, that may be caused by previous operation or injury. The combined determination of CA15-3, CEA and whole body bone scan had a better performance in sensitivity, specificity and accuracy than each single way. Conclusion: The combined determination of CA 15-3, CEA and whole body bone scan were valuable in the diagnosis of bone metastasis in breast cancer. (authors)

  3. Bone marrow dosimetry in peptide receptor radionuclide therapy with [177Lu-DOTA0,Tyr3]octreotate

    International Nuclear Information System (INIS)

    Forrer, Flavio; Krenning, Eric P.; Kooij, Peter P.; Bernard, Bert F.; Bakker, Willem H.; Teunissen, Jaap J.M.; Jong, Marion de; Kwekkeboom, Dik J.; Konijnenberg, Mark; Lom, Kirsten van; Herder, Wouter W. de

    2009-01-01

    Adequate dosimetry is mandatory for effective and safe peptide receptor radionuclide therapy (PRRT). Besides the kidneys, the bone marrow is a potentially dose-limiting organ. The radiation dose to the bone marrow is usually calculated according to the MIRD scheme, where the accumulated activity in the bone marrow is calculated from the accumulated radioactivity of the radiopharmaceutical in the blood. This may underestimate the absorbed dose since stem cells express somatostatin receptors. We verified the blood-based method by comparing the activity in the blood with the radioactivity in bone marrow aspirates. Also, we evaluated the absorbed cross-dose from the source organs (liver, spleen, kidneys and blood), tumours and the so-called ''remainder of the body'' to the bone marrow. Bone marrow aspirates were drawn in 15 patients after treatment with [ 177 Lu-DOTA 0 ,Tyr 3 ]octreotate. Radioactivity in the bone marrow was compared with radioactivity in the blood drawn simultaneously. The nucleated cell fraction was isolated from the bone marrow aspirate and radioactivity was measured. The absorbed dose to the bone marrow was calculated. The results were correlated to the change in platelet counts 6 weeks after treatment. A strong linear correlation and high agreement between the measured radioactivities in the bone marrow aspirates and in the blood was found (r=0.914, p 177 Lu-DOTA 0 ,Tyr 3 ]octreotate, the radioactivity concentration in the bone marrow is identical to that in the blood; (2) There is no significant binding of the radiopharmaceutical to bone marrow precursor stem cells; (3) The contribution of the cross dose from source organs and tumours to the bone marrow dose is significant; and (4) There is considerable variation in bone marrow absorbed dose between patients. These findings imply that for individual dose optimization, individual calculation of the bone marrow absorbed dose is necessary. (orig.)

  4. 99mTc-MDP Bone Scan Findings in Various Clinical Stages of Malignancies

    International Nuclear Information System (INIS)

    Yoon, Hwi Joong; Lee, Myung Chul; Cho, Bo Yeon; Kim, Noe Kyeong; Koh, Chang Soon

    1981-01-01

    Bone scans with 99m Tc-MDP (methylene diphosphonate) were obtained and analysed in 574 from April, 1979 to June, 1931. Clinical staging was done in all patients without bone scan information and compared with bone scan to determine the predictive value of bone scanning. 1) Primary site of the malignancies were lung in 152, breast in 97, stomach in 43, colon in 15, esophagus in 9, liver and pancreas in 11, kidney in 14, bladder in 27, prostate in 22, thyroid in 20, skin in 11, bone in 9, head and neck in 36, ovary and uterus in 17, hematopoietic and lymphoretic ular system in 33, nervous system in 10, and others in 9 cases. Primary site was not defined in 39 cases. 2) Bone scans were positive in 186 cases (32.4%), which, included 48 cases (31.6%) of lung cancer, 27 cases (27.8%) of breast cancer, 12 cases (28%) of stomach cancer, 6 cases (40%) of colon cancer, 6 cases (43%) of kidney tumor, 4 cases (15%) of bladder cancer, 14 cases (64%) of prostate cancer, 3 cases (15%) of thyroid cancer and 66 other cases. 3) Bone scans were suspicious in 64 cases (11.2%) which included 29 cases (19.1%) of lung cancer, 10 cases (10.3%) of breast cancer, 4 cases (9.3%) of stomach cancer, one case (7%) of colon cancer, 3 cases (11%) of bladder cancer, 2 cases (10%) of thyroid cancer and 15 other cases. 4) Out of 121 cases with early stage of malignancy (which included 20 cases of lung cancer in stage I, II, 38 cases of breast cancer, 13 cases of stomach cancer, 8 cases of kidney tumor, 14 cases of thyroid cancer in stage I-III, and 6 cases of colon cancer, 14 cases of bladder cancer, 8 cases of prostate cancer in stage A-C, bone scans were positive in 5 cases (4.1%) which included 3 cases of lung cancer one case of breast cancer and one case of prostate cancer, and considered as further advanced stage, Out of 121 cases with early stage of malignancy, bone scans were suspicious in 21 cases (17.4%) which included 9 cases of lung cancer, 4 cases of breast cancer, 2 cases of stomach

  5. Impact of additional SPECT in bone scanning in tumor patients with suspected metastatic bone disease

    International Nuclear Information System (INIS)

    Apostolova, I.; Goelcuek, E.; Buchert, R.; Brenner, W.; Bohuslavizki, K.H.

    2009-01-01

    The aim of this study was to investigate the additional value of single-photon emission computed tomography (SPECT) for patient staging compared to planar bone scanning in an unselected cohort of cancer patients. The study included 271 consecutive tumor patients in whom planar imaging and two-bed position SPECT of the spine and the pelvis had been performed. Retrospective image interpretation was performed independently for planar and SPECT scans. Findings were categorized as 'benign', 'equivocal', or malignant' on a lesion base, and as 'no metastatic disease', 'equivocal', or metastatic disease' on a patient base. Four hundred and forty seven lesions were detected by SPECT. Missing of lesions in planar images was rare (4.3% of all SPECT lesions). Planar findings differed from SPECT findings in 149 lesions (33.3%). Most of these 'inconsistent' lesions were rated as equivocal in the planar images but benign (14.5% of all lesions) or malignant (11.0%) by SPECT. On a patient base, 81.6% of patients with planar equivocal staging were classified as either benign (55.3%) or malignant (26.3%) by SPECT. Patients definitively staged as 'no metastatic disease' or 'metastatic disease' in planar images were staged differently by SPECT in only 3.7% of cases (up-staging in 2.6% and down-staging in 1.1%). Single-photon emission computed tomography changed a definite staging as based on planar images in less than 4% of the patients. In patients with planar equivocal staging, however, SPECT allowed a definite diagnosis in more than 80% of these cases, and, thus, should be performed routinely in patients with equivocal findings. (author)

  6. The bone scan in tarsal coalition: a case report

    International Nuclear Information System (INIS)

    De Lima, R.T.; Mishkin, F.S.

    1996-01-01

    Tarsal coalition is abnormal fusion of two or more tarsal bones. The union may be fibrous, cartilaginous, or osseous and can be congenital or acquired in response to infection, articular disorders, trauma, or surgery. We report a case of fibrous talocalcaneal coalition in a 15-year-old boy in whom bone scintigraphy employing pinhole lateral views confirmed the clinical diagnosis when plain radiographs showed minimal changes and computed tomography was equivocal. The diagnosis of symptomatic tarsal coalition is important in that it is a common remediable cause of peroneal spastic flat foot, a frequently encountered condition. Scintigraphy provides important information about the presence and localization of this condition. (orig.). With 3 figs

  7. The bone scan in tarsal coalition: a case report

    Energy Technology Data Exchange (ETDEWEB)

    De Lima, R.T. [Department of Radiology, Division of Nuclear Medicine, Harbor-UCLA Medical Center, Torrance, CA (United States); Mishkin, F.S. [Department of Radiology, Division of Nuclear Medicine, Harbor-UCLA Medical Center, Torrance, CA (United States)

    1996-10-01

    Tarsal coalition is abnormal fusion of two or more tarsal bones. The union may be fibrous, cartilaginous, or osseous and can be congenital or acquired in response to infection, articular disorders, trauma, or surgery. We report a case of fibrous talocalcaneal coalition in a 15-year-old boy in whom bone scintigraphy employing pinhole lateral views confirmed the clinical diagnosis when plain radiographs showed minimal changes and computed tomography was equivocal. The diagnosis of symptomatic tarsal coalition is important in that it is a common remediable cause of peroneal spastic flat foot, a frequently encountered condition. Scintigraphy provides important information about the presence and localization of this condition. (orig.). With 3 figs.

  8. The comparing results of carcinoma between three-phase and delayed whole body bone scan

    International Nuclear Information System (INIS)

    Si Hongwei; Li Xianfeng

    2004-01-01

    Purpose: Three phase bone scan is an imaging technology in nuclear medicine, which composed of blood flow phase, blood pool phase and delayed phase and the last one is often performed in routine works in department of nuclear medicine. The purpose of this study is to evaluate the merit of three-phase bone scan.Methods: In this study, we chose 54 patients who were having an regional pain which caused by benign or malignant carcinoma that diagnosed by CT, X-ray, ECT, MRI or other examinations. The imaging were acquired simultaneously from both anterior and posterior views, after a bolus injection of 1110 MBq technetium-99m-labelled methylene diphosphonate (MDP), blood phase contains 20 frame sand 3 seconds per frame, blood pool phase contains 5 frames and 1 minute per frame, delayed phase was performed 2.5 hour later. According to the results of three-phase bone scan, the patients were divided into 2 groups: normal and abnormal groups. The abnormal group includes early phase positive,delay positive and all three phase positive sets. The comparing among the 3 sets were analyzed by chi-square test and other statistic means.Results: There were 54 patients who had suffered lung cancer, breast cancer and other cancer,involved in this study, 34 males and 20 females, ranged age 17 to 88 years, were normal in 15 cases,positive in 22 cases, the results in delayed phase were positive in 9 cases, blood flow and blood pool phase showed blood flow changes in 4 cases and soft tissue tumors were seen in 4 cases. Three phase bone scan was more sensitive than delayed whole body bone scan in detecting the abnormal sites (p 0.05) The sensitivity of detecting tumors in blood flow and blood pool phase,delayed phase were respectively lower than in three phase bone scan (p<0.001).Conclusion: It is more sensitivity of detecting tumor lesions in three phase bone scan than in delayed phase whole body bone scan and the changes of blood flow and soft tissue can be seen in three phase bone scan

  9. Making the invisible body visible. Bone scans, osteoporosis and women's bodily experiences.

    Science.gov (United States)

    Reventlow, Susanne Dalsgaard; Hvas, Lotte; Malterud, Kirsti

    2006-06-01

    The imaging technology of bone scans allows visualization of the bone structure, and determination of a numerical value. Both these are subjected to professional interpretation according to medical (epidemiological) evidence to estimate the individual's risk of fractures. But when bodily experience is challenged by a visual diagnosis, what effect does this have on an individual? The aim of this study was to explore women's bodily experiences after a bone scan and to analyse how the scan affects women's self-awareness, sense of bodily identity and integrity. We interviewed 16 Danish women (aged 61-63) who had had a bone scan for osteoporosis. The analysis was based on Merleau-Ponty's perspective of perception as an embodied experience in which bodily experience is understood to be the existential ground of culture and self. Women appeared to take the scan literally and planned their lives accordingly. They appeared to believe that the 'pictures' revealed some truth in themselves. The information supplied by the scan fostered a new body image. The women interpreted the scan result (a mark on a curve) to mean bodily fragility which they incorporated into their bodily perception. The embodiment of this new body image produced new symptom interpretations and preventive actions, including caution. The result of the bone scan and its cultural interpretation triggered a reconstruction of the body self as weak with reduced capacity. Women's interpretation of the bone scan reorganized their lived space and time, and their relations with others and themselves. Technological information about osteoporosis appeared to leave most affected women more uncertain and restricted rather than empowered. The findings raise some fundamental questions concerning the use of medical technology for the prevention of asymptomatic disorders.

  10. Clinical Utility of bone Scan in the Diagnosis of Temporomandibular disorders

    International Nuclear Information System (INIS)

    Kim, In Joo; Kang, Yang Ho; Son, Seok Man; Lee, Kyoung Seog; Lee, Jae Bok; Kim, Yong Ki; Seo, Bong Jik; Park, June Sang; Park, June Sang; Ko, Myung Yun; Son, Seong Pyo

    1995-01-01

    Bone scan is a very sensitive diagnostic imaging test for detecting bone and joint disorders. So it might be useful in the diagnosis of temporomandibular disorders of the joint origin. Thus, the effectiveness of bone scan for detecting temporomandibular joint(TMJ) diseases and differentiating the TMJ disc displacement from the TMJ arthritis was evaluated. Bone scan was done in 21 patients with TMJ disc displacement (I3 unilaterally affected, 8 bilaterally affected), 26 patients with TMJ arthritis (23 unilateral, 3 bilateral), and 39 volunteers with no signs, symptoms, or history of TMJ disease TMJ simple uptake rate(SUR) and difference of both TMJ SUR were calculated from the 100,000 count lateral image of head and neck region in 99m Tc MDP bone scan. Transcranial and panorama X-ray examination was also done in all patients. TMJ SUR(%) were 1.67 ±0.606 in TMJs affected with arthritis, 1.350±0.351 in TMJs affected with disc displacement, and 1.084±0.172 in TMJs of controls Significant differences were demonstrated among them(p mean+2SD of controls) in unilateral TMJ arthritis patients were significantly higher than those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). Conclusively, bone scan may help to detect TMJ disease and differentiate TMJ disc displacement from TMJ arthritis.

  11. Bone scan appearance of renal osteodystrophy in diabetic chronic renal failure patients

    International Nuclear Information System (INIS)

    So, Young; Hyun, In Young; Lee, Dong Soo; Ahn, Curie; Chung, June-Key; Kim, Suhnggwon; Lee, Myung Chul; Lee, Jung Sang; Koh, Chang-Soon

    1998-01-01

    To investigate Tc-99m methylenediphosphonate (MDP) bone scan appearance in diabetic chronic renal failure patients, we compared the bone scan images of chronic renal failure patients with and without diabetes. The number of patients studied was 134, of whom 43 had diabetes. Two nuclear medicine physicians read Tc-99m MDP bone scan images and for six areas - the axial skeleton, long bone, skull and mandible, periarticular areas, costochondral junction, and sternum - assigned a score of either 1 or 0. The sums of scores were compared. We also performed multivariate analysis including sex, age, and serum creatinine level using analysis of covariance. DM group patients scored significantly lower (2.01±0.95) than those of the non-DM group (3.26±1.16). Analysis of covariance revealed that the lower DM group score was independent of sex, age, and serum creatinine level. The bone scans of diabetic chronic renal failure patients showed less Tc-99m MDP uptake than those of non-diabetic patients. Thus, diagnosing renal osteodystrophy in diabetic chronic renal failure patients on bone scan images could be difficult. (author)

  12. Positive findings on bone scan in multiple myeloma

    International Nuclear Information System (INIS)

    Lin Lin

    2004-01-01

    We report a case of multiple myeloma in which the CT only shows osteolytic lesions and MRI only shows compressive fractrue, but the scan shows some interesting imaging that make us to think of multiple myeloma. (authors)

  13. Is there a role of whole-body bone scan in patients with esophageal squamous cell carcinoma

    Science.gov (United States)

    2012-01-01

    Background Correct detection of bone metastases in patients with esophageal squamous cell carcinoma is pivotal for prognosis and selection of an appropriate treatment regimen. Whole-body bone scan for staging is not routinely recommended in patients with esophageal squamous cell carcinoma. The aim of this study was to investigate the role of bone scan in detecting bone metastases in patients with esophageal squamous cell carcinoma. Methods We retrospectively evaluated the radiographic and scintigraphic images of 360 esophageal squamous cell carcinoma patients between 1999 and 2008. Of these 360 patients, 288 patients received bone scan during pretreatment staging, and sensitivity, specificity, positive predictive value, and negative predictive value of bone scan were determined. Of these 360 patients, surgery was performed in 161 patients including 119 patients with preoperative bone scan and 42 patients without preoperative bone scan. Among these 161 patients receiving surgery, 133 patients had stages II + III disease, including 99 patients with preoperative bone scan and 34 patients without preoperative bone scan. Bone recurrence-free survival and overall survival were compared in all 161 patients and 133 stages II + III patients, respectively. Results The diagnostic performance for bone metastasis was as follows: sensitivity, 80%; specificity, 90.1%; positive predictive value, 43.5%; and negative predictive value, 97.9%. In all 161 patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence-free survival (P = 0.009, univariately). In multivariate comparison, absence of preoperative bone scan (P = 0.012, odds ratio: 5.053) represented the independent adverse prognosticator for bone recurrence-free survival. In 133 stages II + III patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence-free survival (P = 0

  14. Is there a role of whole-body bone scan in patients with esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Li, Shau-Hsuan; Huang, Yung-Cheng; Huang, Wan-Ting; Lin, Wei-Che; Liu, Chien-Ting; Tien, Wan-Yu; Lu, Hung-I

    2012-01-01

    Correct detection of bone metastases in patients with esophageal squamous cell carcinoma is pivotal for prognosis and selection of an appropriate treatment regimen. Whole-body bone scan for staging is not routinely recommended in patients with esophageal squamous cell carcinoma. The aim of this study was to investigate the role of bone scan in detecting bone metastases in patients with esophageal squamous cell carcinoma. We retrospectively evaluated the radiographic and scintigraphic images of 360 esophageal squamous cell carcinoma patients between 1999 and 2008. Of these 360 patients, 288 patients received bone scan during pretreatment staging, and sensitivity, specificity, positive predictive value, and negative predictive value of bone scan were determined. Of these 360 patients, surgery was performed in 161 patients including 119 patients with preoperative bone scan and 42 patients without preoperative bone scan. Among these 161 patients receiving surgery, 133 patients had stages II + III disease, including 99 patients with preoperative bone scan and 34 patients without preoperative bone scan. Bone recurrence-free survival and overall survival were compared in all 161 patients and 133 stages II + III patients, respectively. The diagnostic performance for bone metastasis was as follows: sensitivity, 80%; specificity, 90.1%; positive predictive value, 43.5%; and negative predictive value, 97.9%. In all 161 patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence-free survival (P = 0.009, univariately). In multivariate comparison, absence of preoperative bone scan (P = 0.012, odds ratio: 5.053) represented the independent adverse prognosticator for bone recurrence-free survival. In 133 stages II + III patients receiving surgery, absence of preoperative bone scan was significantly associated with inferior bone recurrence-free survival (P = 0.003, univariately) and overall survival (P = 0

  15. MR imaging of avascular necrosis of the femoral head: Correlation with radiography, radionuclide scan and clinical finding

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Woo, Young Hoon; Joo, Yang Goo; Lee, Sung Moon; Zeon, Seok Kil; Suh, Soo Jhi; Kang, Chang Soo [School of Medicine, Keimyung University, Taegu (Korea, Republic of)

    1992-03-15

    To explore the ability of magnetic resonance imaging(MRI) in the diagnosis of avascular necrosis(AVN) of the femoral head, we compared appearances on MRI of 85 proven AVN lesions with those on radiographs(n=79) and radionuclide scans(n=75). Clinical symptoms(n=85) were also correlated. All MR studies included coronal and axial T1WI and coronal T2WI. All lesions involved the anterosuperterior aspect of the femoral head and were surrounded by a low signal intensity rim on both T1 and T2WI. The signal intensity of the lesions was variable depending on the disease course, and the lesions were divided into four classes according to the classification suggested by Mitchell. Radiographs were normal in 16%(13/79) of the lesions which were in MR class A(10), B(1), C(2). The radionuclide scans showed normal in 16%(12/75) of the lesions which were in MR class A(8). B(1), C(2), D(1). On the other hand, 93% of the lesions with MR class A(27/29) showed stage 1 and 2 lesions on radiographs. Clinical symptoms were absent in 25%(21/85) of the lesions, and among these,81%(17/21) were MR class A. Conclusively, MR is superior to the radiography and radionuclide scan in the early detection of AVN, and can also show the exact location, extent and signal characteristic of the lesion. Therefore, Mr is essential in diagnosis and management of AVN.

  16. MR imaging of avascular necrosis of the femoral head: Correlation with radiography, radionuclide scan and clinical finding

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Woo, Young Hoon; Joo, Yang Goo; Lee, Sung Moon; Zeon, Seok Kil; Suh, Soo Jhi; Kang, Chang Soo

    1992-01-01

    To explore the ability of magnetic resonance imaging(MRI) in the diagnosis of avascular necrosis(AVN) of the femoral head, we compared appearances on MRI of 85 proven AVN lesions with those on radiographs(n=79) and radionuclide scans(n=75). Clinical symptoms(n=85) were also correlated. All MR studies included coronal and axial T1WI and coronal T2WI. All lesions involved the anterosuperterior aspect of the femoral head and were surrounded by a low signal intensity rim on both T1 and T2WI. The signal intensity of the lesions was variable depending on the disease course, and the lesions were divided into four classes according to the classification suggested by Mitchell. Radiographs were normal in 16%(13/79) of the lesions which were in MR class A(10), B(1), C(2). The radionuclide scans showed normal in 16%(12/75) of the lesions which were in MR class A(8). B(1), C(2), D(1). On the other hand, 93% of the lesions with MR class A(27/29) showed stage 1 and 2 lesions on radiographs. Clinical symptoms were absent in 25%(21/85) of the lesions, and among these,81%(17/21) were MR class A. Conclusively, MR is superior to the radiography and radionuclide scan in the early detection of AVN, and can also show the exact location, extent and signal characteristic of the lesion. Therefore, Mr is essential in diagnosis and management of AVN

  17. Scanning usefulness for bone metastases diagnosis in the breast cancer follow-up

    International Nuclear Information System (INIS)

    Guillen, G.; Martinez, P.; Garcia, F.; Tres, A.

    1988-01-01

    It is studied the incidence of osseus metastases and the usefulness of 179 bone scanning realized in the diagnosis and follow-up (average: 23,6 months) of 87 patients operated by breast cancer. It is obvious the scan sensitivity and its unspecificity (15,08% phase-positives). In 13 (14,9%) patients who showed them, during the follow-up, scan was pathological at the moment of the osseus metastases diagnosis or a bit later; there were other clinical data or abnormal analytical ones of suspicion in 77% of them. The time average of appearance is 27 months after surgery. We concluded that the bone scan in the follow-up of breast cancer will be realized only when clinical or analytical suspicion of bone metastases. (Author)

  18. The value of combined examination of serum CYFRA21-1 levels and bone scan in the diagnosis of bone metastasis in lung cancer

    International Nuclear Information System (INIS)

    Yu Jing; Wang Junhong; Zhengping

    2007-01-01

    Objective: To explore the value of combined examination of serum tumor markers CYFRA21-1 and bone scan in the diagnosis of bone metastasis in lung cancer. Methods: Bone scan and serum CYFRA21-1 levels (with CLIA) determination were performed in 138 patients with lung cancer and 56 patients with benign lung diseases. Results: The serum level of CYFRA21-1 were significantly higher in patients with bone metastasis than those in patients without bone metastasis. The levels were also higher in patients without bone metastasis than those in controls. Most patients with bone metastasis had positive results in bone scan (97.4%), only 2 of the 78 had negative bone scan but positive with CT or MRI. A few patients without bone metastasis and controls had positive bone scan results, caused by previous operation or injury. Conclusion: The combined detection of CYFRA21-1 and bone scan were valuable in the diagnosis of bone metastasis of lung cancer. (authors)

  19. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  20. Bone scan in the diagnosis and management of acute osteoarticular infection in children

    International Nuclear Information System (INIS)

    Coll, C.; Massardo, T.; Cifras, J.L.; Moya, H.; Verdugo, M.A.; Soza, F.

    2002-01-01

    Introduction: One of the most important causes of children residual damage in the skeleton in Chile are untreated or treated incompletely osteoarticular infections (OAI). The goal of this study was to assess the value of emergency in-hospital pediatric three-phase bone scan in the evaluation of OAI. Methods: The inclusion criteria were: a) high clinical suspicion of acute OAI and b) a suspect of a secondary localization in a known recent OAI. In this prospective study the gold standard was the final diagnosis at discharge. Thirty-eight children were studied with 54 triphasic bone scans using MDP-Tc99m; some with 4th phase. The population mean age was 4±5 years, 66% of them male. Nine children had their first scan prior to surgical intervention (5 of them had also a posterior follow-up scan) and 17 had a post surgery scan (within a median of 5 days ranging from 1-34 days after surgery). Twelve cases were not submitted to surgery. Results: The global analysis showed 28 cases principally articular and 9 osteomyelitis. The most common germ observed were staphylococcus aureus (37%) and staphylococcus coagulase negative (37%), less common was streptococcus (11%); the hip was affected in 41% of the cases, and less frequently knee and femur. Nine patients with preoperative scans were positive with 16 locations foci. Eighty four % of them were confirmed by surgery/culture (true positive) and surgery was performed within 24 h. There were 3 lesions detected in 2 of the patients with no clinical confirmation (16% false positive). There were not any true negative with surgical confirmation in this group, even though, in 2 clinically suspected sites the bone scan were negative and the patients follow-up was not suggestive of infection in those additional localization. Seven children have negative bone scans (without surgery requirement) that did not present posterior clinical symptomatology in the follow-up up to 3 m. In 5 other cases the vascular phase demonstrated only soft

  1. Bone scan: A useful test for evaluating patients with low back pain

    International Nuclear Information System (INIS)

    Collier, B.D.; Kir, K.M.; Mills, B.J.A.; Patel, N.C.; Pochis, W.T.; Onsel, C.; Liu, Y.; Turoglu, H.T.

    1990-01-01

    For many years it has been known that the sensitivity of bone scanning to the presence of destructive bony lesions favors its use in screning for bone metastases and osteomyelitis. More recently bone scanning has been routinely employed in evaluating benign skeletal pathology that may be the cause of low back pain. Bone scanning can play an important part identifying the cause of pain, clarifying the significance of radiographic findings, and evaluating the results of spinal surgery. This expansion of the role of nuclear medicine in diagnosing and managing low back pain is based in part upon novel diagnostic applications of 99m Tc-methylene diphosphonate, a radiopharmaceutical that has been available for over 15 years. Equally important for this development, however, has been the recent availability of SPECT, a tomographic imaging technique that can be used to display the spine in a series of 6- to 8-mm thick sections. Slightly more than one-half of newly purchased gamma cameras are rotating systems suitable for bone SPECT studies. Thus, many community hospitals can now perform state-of-the-art bone scans for low back pain. (orig.)

  2. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal...

  3. Evaluation of Significance of Diffusely Increased Bilateral Renal Uptake on Bone Scan

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Mi Sook; Yang, Woo Jin; Byun, Jae Young; Park, Jung Mi; Shinn, Kyung Sub; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1990-03-15

    Unexpected renal abnormality can be detected on bone scan using {sup 99m}Tc-MDP. The purpose of the study is to evaluate the diagnostic significance of diffusely increased bilateral renal uptake on bone scan. 1,500 bone scan were reviewed and 43 scans which showed diffusely increased bilateral renal uptake were selected for analysis. Laboratory findings for renal and liver function tests including routine urinalysis were reviewed in 43 patients. 26 of 43 case showed abnormality in urinalysis and renal function study. 20 of 43 cases showed abnormal liver function study and 3 of these cases were diagnosed as hepatorenal syndrome later. 13 of those 20 cases had liver cirrhosis with or without hepatoma. 12 of 43 cases showed abnormality both in renal and liver function studies. 2 of 43 cases showed diffusely increased bilateral renal uptake after chemotherapy for cancer but not on previous scans before chemotherapy. 2 of 43 cases showed hypercalcaemia and 8 of 43 cases had multifocal bone uptake due to metastasis or benign bone lesion. But the latter showed no hypercalcaemia at all. There was no significant correlation between increased renal uptake and MDP uptake in soft tissue other than kidneys. This study raised the possibility that the impaired liver and/or renal function may result in diffuse increase of bilateral renal uptake of MDP of unknown mechanism. It seems to need further study on this correlation.

  4. Evaluation of Significance of Diffusely Increased Bilateral Renal Uptake on Bone Scan

    International Nuclear Information System (INIS)

    Sung, Mi Sook; Yang, Woo Jin; Byun, Jae Young; Park, Jung Mi; Shinn, Kyung Sub; Bahk, Yong Whee

    1990-01-01

    Unexpected renal abnormality can be detected on bone scan using 99m Tc-MDP. The purpose of the study is to evaluate the diagnostic significance of diffusely increased bilateral renal uptake on bone scan. 1,500 bone scan were reviewed and 43 scans which showed diffusely increased bilateral renal uptake were selected for analysis. Laboratory findings for renal and liver function tests including routine urinalysis were reviewed in 43 patients. 26 of 43 case showed abnormality in urinalysis and renal function study. 20 of 43 cases showed abnormal liver function study and 3 of these cases were diagnosed as hepatorenal syndrome later. 13 of those 20 cases had liver cirrhosis with or without hepatoma. 12 of 43 cases showed abnormality both in renal and liver function studies. 2 of 43 cases showed diffusely increased bilateral renal uptake after chemotherapy for cancer but not on previous scans before chemotherapy. 2 of 43 cases showed hypercalcaemia and 8 of 43 cases had multifocal bone uptake due to metastasis or benign bone lesion. But the latter showed no hypercalcaemia at all. There was no significant correlation between increased renal uptake and MDP uptake in soft tissue other than kidneys. This study raised the possibility that the impaired liver and/or renal function may result in diffuse increase of bilateral renal uptake of MDP of unknown mechanism. It seems to need further study on this correlation.

  5. Practical use of bone scan in patients with an osteoporotic vertebral compression fracture.

    Science.gov (United States)

    Jun, Deuk Soo; An, Byoung Keun; Yu, Chang Hun; Hwang, Kyung Hoon; Paik, Je Won

    2015-02-01

    Rib fractures are one of main causes of chest or flank pain when related to an osteoporotic vertebral compression fracture (OVCF). The authors investigated the incidence and risk factors of rib fracture in 284 patients with OVCF using bone scans and evaluated the feasibility as to whether bone scans could be utilized as a useful screening tool. Hot uptake lesions on ribs were found in 122 cases (43.0%). The factors analyzed were age, sex, number and locations of fractured vertebrae, BMD, and compression rates as determined using initial radiography. However, no statistical significances were found. In 16 cases (5.6%), there were concurrent multiple fractures of both the thoracic and lumbar spines not detected by single site MRI. Sixty cases (21.1%) of OVCF with the a compression rate of less than 15% could not be identified definitely by initial plain radiography, but were confirmed by bone scans. It is concluded that a bone scan has outstanding ability for the screening of rib fractures associated with OVCF. Non-adjacent multiple fractures in both thoracic and lumbar spines and fractures not identified definitely by plain radiography were detected on bone scans, which provided a means for determining management strategies and predicting prognosis.

  6. The bone scan in traumatic and sports injuries

    International Nuclear Information System (INIS)

    Matin, P.

    1987-01-01

    There are several types of injuries which are not diagnosable by routine radiographic methods but can be detected easily by nuclear medicine techniques. This chapter describes four primary categories of injury where nuclear medicine techniques may be of use: stress fracture and periosteal injury; covert fractures; joint abnormalities and injuries to connective tissues, especially where they attach to bone; and acute skeletal muscle injury and rhabdomyolysis. One of the most important features of the use of nuclear medicine techniques in the evaluation of sports and traumatic injury is the ability, in most cases, to be able to differentiate among these various categories. Other uses of nuclear medicine techniques are discussed in this chapter

  7. Prospective evaluation of the super scan of metabolic bone disease (abstract)

    International Nuclear Information System (INIS)

    Khan, A.U.; Ahmad, S.; Khan, A.A.; Khan, S.M.; Rauf, M.

    1999-01-01

    A total of 27 cases (23 females and 4 males) having super scan of metabolic bone disease were prospectively evaluated over a period of 2 years (Jan. 1997 to Dec. 1998) at the Nuclear Medicine Department (NMD), institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar to identify various causes for the super scan picture on Tc-99m MDP bone scintigraphy in our clinical environment. After the three observer confirmation of the bone scan, the serum calcium and Parathyroid Hormone (PTH) estimation was done. The patients having serum PTH greater than 250 Pg/L under went two phase Parathyroid MIBI Scintigraphy 2PP MIBI scan) for the detection of parathyroid adenoma. The patients having positive scans for parathyroid Adenoma were subjected to surgery and histopathological confirmation was obtained. Selected cases under went a trial of deport preparation of vitamin D3 calcium supplementation. The final diagnosis of 16 patients was osteomalacia (59%), six patients had histopathologically confirmed parathyroid adenoma (22.2%), one case each was that of toxic thyroid adenoma (3.7%) and chronic renal failure (3.7%). In three cases the final diagnosis was not reached (11.21%). Osteomalacia and parathyroid adenoma are the two most common causes for the super scan picture on bone scintigraphy. (author)

  8. Evaluation of CT-scanning of the temporal bone in the diagnosis of ear diseases

    International Nuclear Information System (INIS)

    Murata, Kiyotaka; Isono, Michio; Nishimae, Tadahide; Tamaki, Katsuhiko; Hosoi, Hiroshi; Ohta, Fumihiko

    1983-01-01

    CT-scanning of 96 temporal bones was carried out to reveal the extension of cholesteatoma, periossicular drainage, fracture lines, enlarged internal acoustic meatus and anomalies of labyrinthine capsules and ossicles. The clinical aspects of CT-scanning of the temporal bone (CTTB) were as follows: 1) Inner ear anomalies were observed in 17 temporal bones of unilateral deafness, high tone loss from unknown origin and fluctuant hearing loss. CTTB may explain the pathology of deafness from unknown origin. 2) Inner ear anomalies may be classified into more detailed groups than before. 3) The extension of cholesteatoma, localization and size of labyrinthine fistula can be estimated prior to surgery. 4) Cholesteatoma in a mastoidectomy cavity may be detected. 5) The malleus and incus may be visualized, although the stapes can hardly be found. 6) Fracture lines of a temporal bone, destruction of the internal acoustic meatus may be clearly detected. (author)

  9. Ewing sarcoma of the rib with normal blood flow and blood pool imagings on a 3-phase bone scan.

    Science.gov (United States)

    Alfeeli, Mahmoud A; Naddaf, Sleiman Y; Syed, Ghulam M S

    2005-09-01

    Ewing sarcoma is the second most common pediatric malignant bone tumor. It usually presents as a hot spot on a 3-phase bone scan as a result of increased vascularity of the tumor and new bone formation. However, aggressive Ewing sarcoma can also appear as a cold lesion. We present the features of a Ewing sarcoma of the rib on a 3-phase bone scan in a child who was being investigated for rib fracture after trauma.

  10. Design, fabrication and evaluation of a new calibration phantom for in vivo measurement of bone-seeking radionuclides (invited paper)

    International Nuclear Information System (INIS)

    Spitz, H.B.; Lodwick, J.

    2000-01-01

    A new anthropometric phantom has been developed for use in calibrating in vivo measurements of bone-seeking radionuclides. The phantom has the external shape and appearance of the human adult knee and contains a realistic femur, patella, tibia, and fibula. Unique formulations of polyurethanes, CaCo 3 , and other trace materials are used in construction of the phantom to produce substitutes for human tissue having the same density, attenuation coefficient, and effective Z as that of human muscle and trabecular bone. The formulation for trabecular bone includes provision for a precisely known quantity of radioactive material that is either uniformly distributed throughout the bone matrix or deposited on the exterior surface. The knee phantom is assembled in three interlocking sections that simplify inserting the skeletal structures and prevent streaming. One or more detectors can easily be positioned on the top or sides of the phantom. Intercomparison measurements of 241 Am in bone using separate arrays of phoswich and germanium detectors demonstrate that a single knee phantom exhibits the same detection efficiency as that using the skull. In vivo measurement of the knee is a desirable alternative to the head if facial contamination is present or when evaluating recent exposure to bone seeking radionuclides, since bones of the knee exhibit more rapid uptake than the skull. In practice, greater measurement efficiency can be obtained by placing detectors over both knees since a larger fraction of the total body activity is observed. Calibration measurements using the new anthropometric knee phantom demonstrate that it is durable, easy to use, and provides consistent results over repeated measurements. (author)

  11. Incidental bone scan findings in oral cavity in patients with cancer

    International Nuclear Information System (INIS)

    Gutierrez G, Patricia; Salvatierra R, Guillermo; Garcia, Arlene; Morales, Rosanna; Cano, Roque; Ortiz L, Jesus; Sotelo R, Silvia; Bustamante, Cesar

    2007-01-01

    The main aim of the present work, done in the Nuclear medicine Center IPEN-INEN, was to identify as incidental findings, increased inflammatory uptake in oral cavity in routine bone scintigraphies for neoplasic diseases control. A descriptive and retrospective study was performed studying bone scans from patients with cancer, that came to the Nuclear Medicine Center in 2003 and revising records of those who had inflammatory uptake in the oral cavity. It is concluded that, in cancer patients these findings are underestimated. Prospective research should be needed in order to determine the frequency of inflammatory oral cavity pathology detected in bone scintigraphies. (author)

  12. Subchondral bone failure in overload arthrosis: a scanning electron microscopic study in horses.

    Science.gov (United States)

    Norrdin, R W; Stover, S M

    2006-01-01

    Mechanical overload leads to a common arthrosis in the metacarpal condyle of the fetlock joint of racehorses. This is usually asymptomatic but severe forms can cause lameness. Subchondral bone failure is often present and the predictability of the site provided an opportunity to study of the progression of bone failure from microcracks to actual collapse of subchondral bone. Twenty-five fetlock condyles from racehorses with various stages of disease were selected. Stages ranged from mild through severe subchondral bone sclerosis, to the collapse of bone and indentation or loss of cartilage known as 'traumatic osteochondrosis'. Parasagittal slices were radiographed and examined with scanning electron microscopy. Fine matrix cracks were seen in the subchondral bone layer above the calcified cartilage and suggested loss of water or other non-collagenous components. The earliest microcracks appeared to develop in the sclerotic bone within 1-3 mm of the calcified cartilage layer and extend parallel to it in irregular branching lines. Longer cracks or microfractures appeared to develop gaps as fragmentation occurred along the margins. Occasional osteoclastic resorption sites along the fracture lines indicated activated remodeling may have caused previous weakening. In one sample, smoothly ground fragments were found in a fracture gap. Bone collapse occurred when there was compaction of the fragmented matrix along the microfracture. Bone collapse and fracture lines through the calcified cartilage were associated with indentation of articular cartilage at the site.

  13. Incidental Visualization of Thyroid Gland on Bone Scan Caused by Graves' Hyperthyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Kim, Dong Wook; Lim, Seok Tae [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-04-15

    A 45-year-old man presented with fatigue and weight loss underwent a Tc-99m MDP bone scan because of increased serum alkaline phosphatase. Delayed images at 4 hours demonstrated diffuse increased activity throughout both lobes of the thyroid in the absence of activity of the stomach and salivary glands. Thyroid laboratory indices and a Tc-99m pertechnetate thyroid scan suggested Graves' hyperthyroidism

  14. Incidental Visualization of Thyroid Gland on Bone Scan Caused by Graves' Hyperthyroidism

    International Nuclear Information System (INIS)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Kim, Dong Wook; Lim, Seok Tae

    2009-01-01

    A 45-year-old man presented with fatigue and weight loss underwent a Tc-99m MDP bone scan because of increased serum alkaline phosphatase. Delayed images at 4 hours demonstrated diffuse increased activity throughout both lobes of the thyroid in the absence of activity of the stomach and salivary glands. Thyroid laboratory indices and a Tc-99m pertechnetate thyroid scan suggested Graves' hyperthyroidism

  15. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee

    2009-01-01

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis

  16. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    2009-08-15

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

  17. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  18. Role of technetium-99m planar bone scanning in the evaluation of low back pain

    International Nuclear Information System (INIS)

    Valdez, D.C.; Johnson, R.G.

    1994-01-01

    The records of 1018 patients with low back pain in a tertiary spine referral practice were reviewed. One hundred thirty-nine out of 1018 (13.6%) underwent technetium-99m planar bone scannings as part of their investigation. Seventy-three out of 139 scans (52%) showed increased uptake in some area, but only 27 out of 139 (19.4%) showed increased uptake specifically in the low back. Scans consistently yielded no findings with reference to the back when the prescan diagnosis was spinal stenosis, lumbar pain syndrome, herniated nucleus pulposus, or postlaminectomy syndrome. Some scans gave positive findings in patients with a diagnosis of degenerative disc disease, pseudoarthrosis, spondylolisthesis, fracture, infection, metabolic disorder, or tumor. Positive scans were generally obtained early after presentation (within 3 months) and negative scans obtained later (after 6 months), suggesting that clinical suspicion is still the main indication for early scanning. Planar bone scanning was helpful in both diagnosis and therapeutic decision-making in many conditions. (orig.)

  19. The value of SPECT bone scans in diagnosis of patients with zygapophseal joint pain

    International Nuclear Information System (INIS)

    Hu Jiajia; Liang Yu; Li Biao; Zhu Chengmo; Chen Gang; Wang Chao; Tian Weijia; Qu Liumin

    2008-01-01

    Objective: Bone scintigraphy with SPECT of the lumbar spine allows identification of lesions not seen with planar imaging, in patients with chronic low back pain. The aim of this study was to investigate the value of SPECT bone scans in diagnosis of patients with zygapophyseal joint pain. Methods: Thirty-five consecutive patients in Ruijin hospital from July 2006 to March 2007 with low back pain were en- rolled. All patients underwent bone scintigraphy with SPECT. According to the results of SPECT, patients with isotope-uptake joints received injections at the levels where abnormalities were identified on the scan. Patients with negative scans received other treatment (conservative treatment or surgery) but not facet joint injection. Clinical records were collected at 1-, 3-, and 6-month in SPECT-positive group after their initial treatment. And the SPECT-negative group were followed up at 6-month after therapy. Statistical analysis was performed with SPSS 10.0. Patients with SPECT-positive and -negative results were performed with the grouped t-test. Visual analog scales (VAS) were with the paired t-test used in patients with positive scans at before and after treatment. Results: Fifteen cases had facetal uptake of isotope on SPECT bone scans. After facet joint injection, 85.7% patients (12/14, 1 patient was excluded for operation) had improvement in pain score at 1-month, 78.6% (11/14) at 3-month, and 50.0% (7/14) at 6-month. Of 20 negative cases, 3 were treated by surgery and 17 by conservative treatment. All 20 cases were followed up for 6 months and 70.0% (14/20) had long time pain relief. Conclusion: SPECT bone scans are helpful to identify patients with low back pain who would benefit from facet joint injections. (authors)

  20. Super bone scan in metastic lung carcinoma: relate of a case

    International Nuclear Information System (INIS)

    Carvalho, A.C.M. de; Calegaro, J.U.M.; Ulyssea, R.

    1985-01-01

    A case of a super bone scan in a patient with a lung cancer is reported. A brief revision of the literature is made with special reference to the causes and physiopathology of this scintigraphic event. The importance of sequential scintigraphic studies in the characterization of the lesions is emphasized. (Author) [pt

  1. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  2. Radiation dose calculations for bone scanning with 99mTc-phosphate compounds in children

    International Nuclear Information System (INIS)

    Schuemichen, C.; Wuest, H.; Hoffmann, G.

    1980-01-01

    The radiation dose after administration of 99m Tc-phosphate compounds for bone scanning will depend on age, the turnover rate and the complex inertness of 99m Tc-phosphate. The preconditions for bone scanning with 99m Tc-phosphate compounds are more favourable in both young and small individuals and hence the calculated soft tissue radiation doses in children are distinctly lower than those reported for adults. After administration of 1 mCi 99m Tc-EHDP or -MDP/kg body weight in children up to one year of age the total radiation dose delivered to bone will be 1 mrad and that to the gonads below 0.5 mrad [fr

  3. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  4. Prediction of Splint Therapy Efficacy Using Bone Scan in Patients with Unilateral Temporomandibular Disorder

    International Nuclear Information System (INIS)

    Lee, Sang Mi; Lee, Won Woo; Yun, Pil Young; Kim, Young Kyun; Kim, Sang Eun

    2009-01-01

    It is not known whether bone scan is useful for the prediction of the prognosis of patients with temporomandibular disorders (TMD). The aim of the present study was to identify useful prognostic markers on bone scan for the pre-therapeutic assessment of patients with unilateral TMD. Between January 2005 and July 2007, 55 patients (M:F=9:46; mean age, 34.7±14.1 y) with unilateral TMD that underwent a pre-therapeutic bone scan were enrolled. Uptake of Tc-99m HDP in each temporomandibular joint (TMJ) was quantitated using a 13X13 pixel-square region-of-interest over TMJ and parietal skull area as background. TMJ uptake ratios and asymmetric indices were calculated. TMD patients were classified as improved or not improved and the bone scan findings associated with each group were investigated. Forty-six patients were improved, whereas 9 patients were not improved. There was no significant difference between the two groups of patients regarding the TMJ uptake ratio of the involved joint, the TMJ uptake ratio of the non-involved joint, and the asymmetric index (p>0.05). However, in a subgroup analysis, the patients with an increased uptake of Tc-99m HDP at the disease-involved TMJ, by visual assessment, could be easily identified by the asymmetric index; the patients that improved had a higher asymmetric index than the patients that did not improve (1.32±0.35 vs. 1.08±0.04, p=0.023), The Tc-99m HDP bone scan may help predict the prognosis of patients with unilateral TMD after splint therapy when the TMD-involved joint reveals increased uptake by visual assessment

  5. Prediction of Splint Therapy Efficacy Using Bone Scan in Patients with Unilateral Temporomandibular Disorder

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Mi; Lee, Won Woo; Yun, Pil Young; Kim, Young Kyun; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul (Korea, Republic of)

    2009-04-15

    It is not known whether bone scan is useful for the prediction of the prognosis of patients with temporomandibular disorders (TMD). The aim of the present study was to identify useful prognostic markers on bone scan for the pre-therapeutic assessment of patients with unilateral TMD. Between January 2005 and July 2007, 55 patients (M:F=9:46; mean age, 34.7{+-}14.1 y) with unilateral TMD that underwent a pre-therapeutic bone scan were enrolled. Uptake of Tc-99m HDP in each temporomandibular joint (TMJ) was quantitated using a 13X13 pixel-square region-of-interest over TMJ and parietal skull area as background. TMJ uptake ratios and asymmetric indices were calculated. TMD patients were classified as improved or not improved and the bone scan findings associated with each group were investigated. Forty-six patients were improved, whereas 9 patients were not improved. There was no significant difference between the two groups of patients regarding the TMJ uptake ratio of the involved joint, the TMJ uptake ratio of the non-involved joint, and the asymmetric index (p>0.05). However, in a subgroup analysis, the patients with an increased uptake of Tc-99m HDP at the disease-involved TMJ, by visual assessment, could be easily identified by the asymmetric index; the patients that improved had a higher asymmetric index than the patients that did not improve (1.32{+-}0.35 vs. 1.08{+-}0.04, p=0.023), The Tc-99m HDP bone scan may help predict the prognosis of patients with unilateral TMD after splint therapy when the TMD-involved joint reveals increased uptake by visual assessment.

  6. Radionuclide toxicity

    International Nuclear Information System (INIS)

    Galle, P.

    1982-01-01

    The aim of this symposium was to review the radionuclide toxicity problems. Five topics were discussed: (1) natural and artificial radionuclides (origin, presence or emission in the environment, human irradiation); (2) environmental behaviour of radionuclides and transfer to man; (3) metabolism and toxicity of radionuclides (radioiodine, strontium, rare gas released from nuclear power plants, ruthenium-activation metals, rare earths, tritium, carbon 14, plutonium, americium, curium and einsteinium, neptunium, californium, uranium) cancerogenous effects of radon 222 and of its danghter products; (4) comparison of the hazards of various types of energy; (5) human epidemiology of radionuclide toxicity (bone cancer induction by radium, lung cancer induction by radon daughter products, liver cancer and leukaemia following the use of Thorotrast, thyroid cancer; other site of cancer induction by radionuclides) [fr

  7. Image interpolation allows accurate quantitative bone morphometry in registered micro-computed tomography scans.

    Science.gov (United States)

    Schulte, Friederike A; Lambers, Floor M; Mueller, Thomas L; Stauber, Martin; Müller, Ralph

    2014-04-01

    Time-lapsed in vivo micro-computed tomography is a powerful tool to analyse longitudinal changes in the bone micro-architecture. Registration can overcome problems associated with spatial misalignment between scans; however, it requires image interpolation which might affect the outcome of a subsequent bone morphometric analysis. The impact of the interpolation error itself, though, has not been quantified to date. Therefore, the purpose of this ex vivo study was to elaborate the effect of different interpolator schemes [nearest neighbour, tri-linear and B-spline (BSP)] on bone morphometric indices. None of the interpolator schemes led to significant differences between interpolated and non-interpolated images, with the lowest interpolation error found for BSPs (1.4%). Furthermore, depending on the interpolator, the processing order of registration, Gaussian filtration and binarisation played a role. Independent from the interpolator, the present findings suggest that the evaluation of bone morphometry should be done with images registered using greyscale information.

  8. Influence of antibacterial therapy on bone scan indices at foot inflammation in diabetes mellitus accompanied by diabetic foot syndrome

    International Nuclear Information System (INIS)

    Slavnov, V.M.; Bolgars'ka, S.V.; Taran, E.V.; Markov, V.V.

    2004-01-01

    The influence of antibacterial therapy on bone scan indices at foot inflammation in patients with diabetes mellitus (DM) accompanied by diabetic foot syndrome was studied. Bone scan was performed using scintillation tomographic gamma-camera hours after intravenous injection of 99m Tc-methylene diphosphonate

  9. Age- and sex-related bone uptake of Tc-99m-HDP measured by whole-body bone scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, W.; Sieweke, N.; Kampen, W.U.; Zuhayra, M.; Henze, E. [Klinik fuer Nuklearmedizin, Univ. Kiel (Germany); Bohuslavizki, K.H.; Clausen, M. [Abt. Nuklearmedizin, Universitaetskrankenhaus Eppendorf, Hamburg (Germany)

    2000-08-01

    Aim of this study was to validate a recently introduced new and easy-to-perform method for quantifying bone uptake of Tc-99m-labelled diphosphonate in a routine clinical setting and to establish a normal data base for bone uptake depending on age and gender. Methods: In 49 women (14-79 years) and 47 men (6-89 years) with normal bone scans as well as in 49 women (33-81 years) and 37 men (27-88 years) with metastatic bone disease whole-body bone scans were acquired at 3 min and 3-4 hours p.i. to calculate bone uptake after correction for both urinary excretion and soft tissue retention. Results: Bone uptake values of various age-related subgroups showed no significant differences between men and women (p>0.05). Furthermore, no differences could be proven between age-matched subgroups of normals and patients with less than 10 metastatic bone lesions, while patients with wide-spread bone metastases revealed significantly increased uptake values. In both men and women highest bone uptake was obtained (p<0.05) in subjects younger than 20 years with active epiphyseal growth plates. In men, bone uptake slowly decreased with age up to 60 years and then showed a tendency towards increasing uptake values. In women, the mean uptake reached a minimum in the decade 20-29 years and then slowly increased with a positive linear correlation of age and uptake in subjects older than 55 years (r=0.57). Conclusion: Since the results proposed in this study are in good agreement with data from literature, the new method used for quantification could be validated in a large number of patients. Furthermore, age- and sex-related normal bone uptake values of Tc-99m-HDP covering a wide range of age could be presented for this method as a basis for further studies on bone uptake. (orig.) [German] Ziel dieser Studie war die Validierung einer von uns neu entwickelten einfachen Methode zur Quantifizierung des Skelettuptake von Tc-99m-HDP im Rahmen der klinischen Routineanwendung und die Erstellung

  10. Current role of bone scan with phosphonates in the follow-up of breast cancer

    International Nuclear Information System (INIS)

    Maffioli, Lorenzo; Florimonte, Luigia; Pagani, Luca; Butti, Ivana; Roca, Isabel

    2004-01-01

    A number of studies have demonstrated that bone scintigraphy has high sensitivity and efficacy in the early detection of bone metastases from several tumours, including breast cancer. Bone scintigraphy is the most definitive tool for diagnosing and monitoring metastatic spread of breast cancer. However, in the past decade there has been a wide debate on its impact on survival time, morbidity and quality of life. Worldwide economic restrictions and these studies have led to the adoption of an almost minimalist policy for breast cancer follow-up using evidence-based guidelines. The recommended breast cancer surveillance testing includes only a few procedures (history, physical and breast self-examination, patient education on symptoms, pelvic examination). The routine use of additional tests, such as blood cell count, tumour markers, liver ultrasonography, bone scan and chest X-rays, is not recommended. Accordingly, scintigraphy should be reserved for a limited number of patients. On the other hand, early diagnosis of bone involvement may reduce the risk of skeletal related events, thus leading to a significant improvement in quality of life. Furthermore, new drugs (e.g. bisphosphonates) can now delay the onset of bone metastasis and reduce the number of patients who experience skeletal complications. In conclusion, the evidence of the clinical usefulness of bone scintigraphy (to allow early planning of new treatments in advanced disease) has to be re-evaluated, possibly by large randomised prospective trials. (orig.)

  11. Module for applications of bone scan in cancer patients; Modulo para solicitudes de gammagrafia osea en pacientes con cancer

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Rosanna; Cano, Roque; Velasquez, Maria [Centro de Medicina Nuclear, Instituto Peruano de Energia Nuclear, Lima (Peru); Vasquez, Edinson; Diaz, Pepe; Vasquez, Mario; Rojas, Peter [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Surquillo, Lima (Peru)

    2013-07-01

    This paper reports the application of a software which enables the complete register of patient data, for delivering appropriate information in bone scan reports. Bone scan is a frequent study in Nuclear Medicine, which enables physicians to diagnose a primary bone cancer or metastases. The software was designed in order to complete data given by oncologists and constitutes an aid for the health team attending patients. (authors).

  12. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A. [The University of Iowa, Department of Biomedical Engineering, Center for Computer Aided Design, Iowa City, IA (United States); Shivanna, Kiran H. [The University of Iowa, Center for Computer Aided Design, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Department of Radiology, Center for Computer Aided Design, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Center for Computer Aided Design, Iowa City, IA (United States)

    2008-01-15

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  13. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    International Nuclear Information System (INIS)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A.; Shivanna, Kiran H.; Magnotta, Vincent A.; Grosland, Nicole M.

    2008-01-01

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  14. Paucity of bone scan abnormalities in a child with multifocal osteomyelitis and disseminated sepsis

    International Nuclear Information System (INIS)

    Trpezanovski, J.; Porn, U.; Uren, R.; Howman-Giles, R.; Mansberg, R.

    2000-01-01

    Full text: We present an unusual case of multifocal osteomyelitis with minimal bone scan abnormalities and markedly discordant findings on Magnetic Resonance Imaging(MRI) and gallium scans. A seven-year-old female presented with left leg, right elbow pain and fever. A bone scan was performed. Mild increased vascularity was demonstrated on the dynamic and blood pool phases of the study in the area of the right elbow. In the delayed images there was a photopenic lesion in the left distal femoral metadiaphysis and also irregular uptake in the metaphyseal regions of the long bones. Low grade soft tissue tracer uptake was seen in the left thigh and right forearm. The patient deteriorated clinically and underwent further investigations with MRI and gallium scans. The MRI showed extensive abnormalities with mulitlocular fluid collection seen throughout most of the muscle groups of both thighs suggesting myositis with an associated cellulitis and osteomyelitis of the left femur. The gallium study was markedly abnormal with increased uptake in the distal 2/3rds of the left femur, proximal 1/2 of the right femur, right proximal forearm (mid forearm extending to mid upper arm), left proximal humerus and right hemithorax especially the lower zones. Staphylococcal aureus was cultured. The patient required intensive care management and slowly responded to antibiotic therapy and surgery to drain abscesses in the thighs. A bone marrow biopsy was normal and immunological tests were performed but a result has yet to be determined. The lack of increased bone uptake in the demonstrated areas of osteomyelitis maybe explained on the basis of an overwhelming infective process inhibiting the patient's healing response. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  15. Incidental finding of knee osteoarthritis in bone scans performed in obese patients with neoplasia

    International Nuclear Information System (INIS)

    Regalado R, R.; Morales G, R.; Cano P, R.; Mendoza P, G.; Vidal N, L.

    1996-01-01

    Bone scanning performed in the Nuclear Medicine Center (IPEN-INEN) to patients with neoplastic diagnosis between January 1995 and June 1996, permitted the incidental finding of increased uptake images in the knees of 28 patients associated to an asymptomatic arthropathy: osteoarthritis. The histories and bone scanning of this patients were reviewed obtaining their weight, occupation, symptomatology, neoplastic diagnosis and previous scan diagnosis. Patients under 66 years old, asymptomatic, were included, not presenting secondary focuses, without arthropathia antecedent and with a body mass index equal or above class I. The arthropathy was classified according to the localization of the compromised compartment of the knee. >From the body mass index assessment of every patient it was obtained: Class I=12, Class II=11, Class III=3 and Class IV=1. The predominant localization of the osteoarthritic lesions was the patellar zone. We discuss factors that may influence the absence of symptoms of this disease, the relation obesity-osteoarthritis and the usefulness of bone scanning in the diagnosis of this arthropathy in these patients. (authors). 16 refs., 1 fig., 3 tabs

  16. Radionuclide scanning in a study of the pulmonary blood flow with the open arterial canal

    International Nuclear Information System (INIS)

    Rizaev, M.N.; Gulyamov, D.S.; Khodzhibekov, M.Kh.; Anvarov, M.A.

    1980-01-01

    Characteristic features of the distribution of the arterial pulmonary blood flow have been studied in 32 patients with the open arterial flow by lung scanning with albumin macroaggregate and 131 I. Research was conducted using the gamma-Ochamber ''Fo Gamma LFV'' and the scanner ''Magnaskaner 500I''. Disordered distribution of the pulmonary blood flow expressed in its unilateral decrease was detected in 17 patients (52.9%). A higher frequency of pulmonary hypertension was noted in these patients versus those with a relatively normal distribution of the pulmonary blood flow. A severe course of the disease was observed in high pulmonary hypertension combined with sharp suppression of the blood flow in one of the lungs or with signs of the shift from the right to the left side

  17. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  18. In situ repair of bone and cartilage defects using 3D scanning and 3D printing

    OpenAIRE

    Li, Lan; Yu, Fei; Shi, Jianping; Shen, Sheng; Teng, Huajian; Yang, Jiquan; Wang, Xingsong; Jiang, Qing

    2017-01-01

    Three-dimensional (3D) printing is a rapidly emerging technology that promises to transform tissue engineering into a commercially successful biomedical industry. However, the use of robotic bioprinters alone is not sufficient for disease treatment. This study aimed to report the combined application of 3D scanning and 3D printing for treating bone and cartilage defects. Three different kinds of defect models were created to mimic three orthopedic diseases: large segmental defects of long bon...

  19. Pinhole bone scan mapping of metabolic profiles in osteoarthritis of the knee: a radiographic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Kim, H. H.; Chung, Y. A.; Chung, S. K.; Bahk, Y. W. [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    1999-07-01

    Osteoarthritis (OA) is mixture of damage to a joint and reaction induced therefrom. Heterogeneity, slow change and no proper means of assessing pathology make it a difficult disease to study. Diagnosis can be made by radiography when OA is established. But subtle metabolic change without radiographic alteration can only be detected by bone scan. Present study was performed to assess metabolic profiles of OA of the knee with various radiographic and preradiographic changes using pinhole bone scan (PBS). PBS and radiography were taken at the same time or a few days apart. We used single-head gamma camera and a 4-mm pinhole collimator. Patients were 9 men and 19 women (30-74 yr with mean being 55). PBS was correlated with radiography in each case. Increased tracer uptake was seen in 111 lesions in 28 knees. Intensity was arbitrarily graded into Grade 0-2. The results were divided into group with radiographic change (n=85; Table) and group without (n=26). Generally, tracer uptake was much intense in the sclerotic and cystic form. In radiographically normal group pathological uptake occurred mostly in subchondral bone (n=17) and some in the femoral condyle (n=9) denoting that subchondral bone is the most vulnerable. PBS is sensitive indicator of metabolic alternations in various disease processes of OA in both radiographically normal and abnormal cases.

  20. A Study on Clinical Activity of Myositis by the Use of Radioisotope Bone Scan in the Patients with Dermatomyositis - polymyositis

    International Nuclear Information System (INIS)

    Choi, Sung Jae; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness of radioisotope bone scan and clinical activity of myositis, bone scan using 99m Tc-Methylene diphosphonate was serially done before and after treatment with prednisolone in 10 patients with well- documented dermatomyositis-polymyositis. The observed results were as follows. 1. In all 10 patients before treatment with prednisolone, the bone scans showed evidence of increased muscle uptake. Muscle uptake was markedly increased in 4 patients, moderately increased in 3 patients and minimally increased in 3 patients. 2. The site of increased muscle uptake was consistent with the site of clinically involved muscle which was weak and tender. 3. The degree of muscle uptake correlated with the severity of the muscle weakness and tenderness at the scan was done. In all 10 patients treated with high dose prednisolone, muscle uptake was decreased following therapy. Above results suggest the radioisotope bone scanning may be useful in the diagnosis and treatment of patient with dermatomyositis-polymyositis.

  1. In situ repair of bone and cartilage defects using 3D scanning and 3D printing.

    Science.gov (United States)

    Li, Lan; Yu, Fei; Shi, Jianping; Shen, Sheng; Teng, Huajian; Yang, Jiquan; Wang, Xingsong; Jiang, Qing

    2017-08-25

    Three-dimensional (3D) printing is a rapidly emerging technology that promises to transform tissue engineering into a commercially successful biomedical industry. However, the use of robotic bioprinters alone is not sufficient for disease treatment. This study aimed to report the combined application of 3D scanning and 3D printing for treating bone and cartilage defects. Three different kinds of defect models were created to mimic three orthopedic diseases: large segmental defects of long bones, free-form fracture of femoral condyle, and International Cartilage Repair Society grade IV chondral lesion. Feasibility of in situ 3D bioprinting for these diseases was explored. The 3D digital models of samples with defects and corresponding healthy parts were obtained using high-resolution 3D scanning. The Boolean operation was used to achieve the shape of the defects, and then the target geometries were imported in a 3D bioprinter. Two kinds of photopolymerized hydrogels were synthesized as bioinks. Finally, the defects of bone and cartilage were restored perfectly in situ using 3D bioprinting. The results of this study suggested that 3D scanning and 3D bioprinting could provide another strategy for tissue engineering and regenerative medicine.

  2. Bone scanning in patients with low back pain following minimal trauma

    International Nuclear Information System (INIS)

    Weidinger, W.; Hatzl-Griesenhofer, M.; Pichler, R.; Huber, H.; Maschek, W.

    2002-01-01

    Full text: Low back pain following minimal trauma may be caused by insufficiency fracture of the sacrum, which is often radiographically occult. Bone scintigraphy is a method of reference for the diagnosis; the results have been analyzed retrospectively. Bone scintigraphy was done on 228 patients treated by the departments of orthopedics at the General Hospital Linz. Predominantly after (minor) trauma, they suffered from lower back pain and their conventional radiographic findings were negative. During a 24 month period, a sacral insufficiency fracture was diagnosed in 68 patients (29,8 %). H-shaped hyperfixation of the tracer - described as typical - was present in only 12 % of the gases. Tracer accumulation was found as follows: located uni/bilateral in the sacral wings (39 % / 9 %), horizontal (31 %) and half H-shaped (9 %). In the majority of the gases bone scan detected farther fractures with main localization in the pubic bones, in the spine and the ribs. The insufficiency fracture of the sacrum as cause of lower back pain is not uncommon, especially in postmenopausal women with risk factors. Bone scintigraphy is not only an adequate procedure for the detection of often radiographically occult sacral fractures, but also an easy method to reveal the often concomitand fractures. (author)

  3. 99mTc-MDP bone scanning of patients with diffuse metastatic carcinoma of the axial skeleton

    International Nuclear Information System (INIS)

    Morita, Seiichiro; Ishibashi, Masatoshi; Takahashi, Kazuyuki; Funatsu, Kazuhiro; Yoshii, Toshiaki; Shirabe, Ichiju; Nomura, Yasushi; Ohtake, Hisashi

    1990-01-01

    Fifteen bone scintigrams in patients with diffuse bone metastases were reviewed because of the diffuse radionuclide accumulation in the axial skeleton. Diagnoses were gastric cancer in 6 patients, prostatic cancer in 5, breast cancer in 3, and renal pelvic tumor in one. In 5 patients with gastric cancer, one with prostatic cancer, and one with renal pelvic tumor, initial bone scintigraphy showed diffuse accumulation. In one gastric cancer patient and two breast cancer patients, the multiple bone metastases had altered the diffuse bone metastasis. All patients had no lung or liver metastasis morphologically at the course of diagnosed diffuse bone metastasis. Overall, the diffuse bone metastases were classified into two groups: diffuse symmetrical accumulation in proportion to bone marrow demonstrated in the gastric cancer, and diffuse accumulation centering the axial skeleton with asymmetrical accumulation in the rib and extremities demonstrated in cancer of the prostate. The finding of X ray films were consistent to common bone metastases in proportion to the primary tumor. Diffuse bone metastases did not show the characteristic finding. During the period from the diagnosed time to the death of patients, the patients with gastric cancer died extremely earlier in comparison to the patients with breast cancer and with prostatic cancer. (author)

  4. Can tumour marker assays be a guide in the prescription of bone scan for breast and lung cancers?

    Energy Technology Data Exchange (ETDEWEB)

    Buffaz, P.-D.; Gauchez, A.S.; Caravel, J.P.; Vuillez, J.P.; Cura, C.; Agnius-Delord, C.; Fagret, D. [Service de Medecine Nucleaire, Centre Hospitalier Universitaire de Grenoble (France)

    1999-01-01

    Considering the current need to improve cost-effectiveness in cancer patient management, a prospective study was undertaken in order to define the optimal combination of bone scan and tumour marker assays in breast and lung cancer strategies, as has been done in the case of prostate cancer. All patients with breast or lung cancer referred to the Nuclear Medicine Department of the Grenoble Teaching Hospital between December 1995 and April 1997 were included. A blood sample was drawn in each case for marker assay (CA15-3 or CEA and CYFRA 21-1) on the same day as the bone scan. Two hundred and seventy-five patients were included: 118 with lung cancer and 157 with breast cancer. With regard to lung cancer, no information useful for guiding bone scan prescription was obtained through CEA and CYFRA 21-1 assays. For breast cancer, the results suggest that in asymptomatic patients, a CA15-3 level of less than 25 U/ml (upper normal value chosen as the threshold) is strongly predictive of a negative bone scan; by contrast, high tumour marker levels are predictive of neoplastic bone involvement. When a doubtful bone scan is obtained in a patient with breast cancer, a normal marker level makes it highly probable that bone scan abnormalities are not related to malignancy. (orig.) With 3 figs., 21 refs.

  5. 99mTc-MDP Three Phase Bone Scan - An Important Imaging Modality in the Diagnosis of Bone Infection in Children

    International Nuclear Information System (INIS)

    Sethi, R.S.; Mittal, B.R.; Bhattacharya, A.; Singh, B.; Jindal, S.K.

    2002-01-01

    In patients suspected to have osteomyelitis, three-phase bone scan is one of the earlier investigations to become positive. Early diagnosis helps in starting the appropriate therapy and thus reducing morbidity. A retrospective analysis of scintigraphic findings of 53 children (37 boys, 16 girls) with mean age of 7.4 years (25 days - 2 years), referred for three-phase bone scan to rule out osteomyelitis was done. The presenting signs and symptoms in all children in order of frequency were swelling of body part, guarding, fever of unknown origin. Limitation of movement of body part was the most frequent sign in infants below 6 months of age. In 32 (60.3%) of these 53 children, x-rays were normal. Eleven (20.7%) of the 53 children had normal three phase bone scan. Nine children (16.9%) had increased blood flow along with increased soft tissue tracer concentration in the involved area suggesting soft tissue inflammation / infection. Five (9.4%) children who presented with multiple abscesses over extremities with the suspicion of immunodeficiency also had positive three-phase bone scan. All these 5 children had pus culture positive for staphylococcus aureus. Four (7.5%) children had thalassemia major and were on regular blood transfusion. Three of these 4 children showed positive three-phase bone scan while in the fourth patient bone phase (3rd phase) was normal suggesting soft tissue inflammation only. One child who was a case of Non-Hodgkin's lymphoma and had recently finished chemotherapy also showed positive three-phase bone scan. One infant who had positive three-phase bone scan with nonspecific abnormality on chest x-ray was diagnosed to have Caffey's disease, while his other twin showed a normal bone scan. In twenty-four children (45.2%) three-phase bone scan was positive involving mostly one extremity. According to the frequency of site of involvement these were knee, elbow and ankle. Most frequent bones involved were femur followed by humerus. Staphylococcus

  6. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    Science.gov (United States)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  7. Investigation of computer-aided diagnosis system for bone scans: a retrospective analysis in 406 patients.

    Science.gov (United States)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, Lars

    2014-05-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N = 71), breast cancer (N = 109), males with other cancers (N = 153), and females with other cancers (N = 73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The PPVs of the group with prostatic cancer (51.0 %) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5 %) was significantly higher than that of the group with breast cancer (68.6 %) and the females with other cancers (65.9 %) (P < 0.01). For the evaluation of the ROC analysis of region-based ANN, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (ANN = 0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (ANN = 0.7), 0.81 (ANN = 0.5), and 0.81 (ANN = 0.6), respectively. The special CAD system "BONENAVI" trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion

  8. Investigation of computer-aided diagnosis system for bone scans. A retrospective analysis in 406 patients

    International Nuclear Information System (INIS)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, L.

    2014-01-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N=71), breast cancer (N=109), males with other cancers (N=153), and females with other cancers (N=73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The Pps of the group with prostatic cancer (51.0%) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5%) was significantly higher than that of the group with breast cancer (68.6%) and the females with other cancers (65.9%) (P < 0.01). For the evaluation of the Roc analysis of region-based Ann, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (Ann=0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (Ann=0.7), 0.81 (Ann=0.5), and 0.81 (Ann=0.6), respectively. The special CAD system 'Bovine' trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion of the cancer is

  9. Correlative study of SPECT bone scan, serum tPSA and fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis

    International Nuclear Information System (INIS)

    Xu Haiqing; Duan Jun

    2011-01-01

    Objective: To study the rules and characteristics of SPECT bone scan, serum TPSA, fPSA/tPSA ratio and the pathological grade of prostate cancer with bone metastasis. Methods: Nuclear medicine SPECT bone scan as the gold standard, retrospective analysis of the in vitro radioimmunoassay in 107 patients with prostate cancer serum PSA (prostate specific antigen) levels, serum fPSA/tPSA ratio and whole body bone imaging studies and pathological classification. Results: 107 patients with prostate cancer : 49 patients had bone metastases, accounting for 45.8% (49/107), in which groups of different pathological comparison between the incidence of bone metastasis significantly, the lower the degree of differentiation, the more the incidence of bone metastases high; with elevated levels of tPSA, the incidence of bone metastasis increased significantly; serum tPSA 4 - 40 ng/ml, the use of fPSA/tPSA ratio may improve the diagnostic specificity of prostate cancer. Conclusion: Patients with bone metastases of prostate cancer incidence and degree of differentiation of prostate cancer, serum PSA levels and fPSA/tPSA ratio of a certain relationship. The lower degree of differentiation,the higher the incidence of bone metastasis. (authors)

  10. Relative accretion of /sup 99m/Tc-polyphosphate by forming and resorbing bone systems in rats: its significance in the pathologic basis of bone scanning

    International Nuclear Information System (INIS)

    Garcia, D.A.; Tow, D.E.; Kapur, K.K.; Wells, H.

    1976-01-01

    The relative roles of osteogenesis and osteolysis in the production of positive radionuclide images of skeletal lesions were investigated. The uptake of /sup 99m/Tc-polyphosphate (Tc-PP) by each process was measured in an animal model that permitted bone formation and resorption to be studied independently. Ten rats received intramuscular implants of bone-forming demineralized matrix (DM) and resorbing devitalized bone (DV). Radiographs and Tc-PP scintiscans were made each week thereafter. At 6 to 10 weeks, the implants and normal bone samples were removed, counted for /sup 99m/Tc, and examined histologically. The uptake of Tc-PP by DM implants was first detected on images made 3 weeks after implantation, and by DV implants, 1 to 2 weeks later. Serial radiography showed progressive calcification of DM and resorption of DV implants. Microscopic examinations of undecalcified sections, stained with a modified Goldner preparation, revealed vital-bone formation in the DM implants and osteoclastic resorption in the DV. Activity counts per gram of DM and DV implants were, respectively, 200 percent and 90 percent that of normal bone. Since only the bone-forming system (DM) accumulated Tc-PP at greater than normal concentrations, this study indicates that positive bone images of osteolytic lesions solely reflect compensatory osteogenic responses

  11. Combined bilateral idiopathic necrosis of the humerus and femur heads: Bone scan, X-ray, CT, and MRI findings

    International Nuclear Information System (INIS)

    Piepenburg, R.; Hahn, K.; Doll, G.; Grimm, J.

    1992-01-01

    Untreated aseptic bone necroses close to a joint commonly leads to severe secondary arthrosis and destruction of the joint within a short time. Therefore, only a diagnosis in an early stage of the disease offers the chance of a successful joint- preserving therapy. In cases of clinically suspected aseptic bone necrosis but still negative or doubtful X-ray findings, bone scans or MRI are reliable methods of verifying the diagnosis. (orig./MG) [de

  12. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    International Nuclear Information System (INIS)

    Yunus, Barunawaty

    2011-01-01

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  13. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement.

    Science.gov (United States)

    Yunus, Barunawaty

    2011-06-01

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  14. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    Energy Technology Data Exchange (ETDEWEB)

    Yunus, Barunawaty [Faculty of Dentistry, Hasanuddin University, Makassar (Malaysia)

    2011-06-15

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  15. Clinical value of combined detection of serum tumor markers and whole body bone scan for diagnosis of bone metastases from breast cancer

    International Nuclear Information System (INIS)

    Gao Chao; Zhao Jing; Liu Desheng; Zhang Jingchuan; Ji Xuejing; Hou Xiancun

    2007-01-01

    Objective: To study the clinical value of serum tumor marker determination and whole body bone scan for diagnosis of bone metastases from breast cancer. Methods: Serum tumor markers (CA15-3, CEA, TSGF)were detected with GLIA and whole body bone scan were investigated by SPECT in 124 breast cancer patients. Results: In 124 patients, 38 patients were diagnosed as positive for bone metastases with whole body bone scan. The positive predicting values of CA15-3, CEA, TSGF were 76.78%, 80% and 82.14%, and the negative predicting values of CA15-3, GEA, TSGF were 82.41%, 86.74% and 84.29% respectively. The levels of CA15-3, CEA, TSGF in patients with bone metastases were significantly higher than those in patients without metastasis and the controls (P<0.01). Conclusion: Determination of levels of serum tumor markers CA15-3, CEA, TSGF is helpful for diagnosis of bone metastases from breast cancer. Combined detection of GA15-3, CEA, TSGF could increase the sensitivity and accuracy of diagnosing bone metastases. (authors)

  16. Radionuclide bone imaging in spondylolysis of the lumbar spine in children

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Strife, J.L.; Kereiakes, J.G.

    1981-01-01

    Bone scintigraphy and radiography were performed in seven children with back pain. Six of the children with radiographic evidence of a pars interarticularis defect also had abnormal scintigrams. Increased uptake of the bone imaging agent occurred at six of the ten sites of radiographic pars interarticularis defects, implying increased bone metabolic activity. However, the location of scintigraphic abnormalities did not correspond to the location of radiographic abnormalities in several cases. Measurements of absorbed radiation dose indicate that plain radiography, including oblique views where appropriate, has a lower absorbed radiation dose than scintigraphy or tomography and should be performed prior to these studies

  17. Radionuclide bone imaging in spondylolysis of the lumbar spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Gelfand, M.J.; Strife, J.L.; Kereiakes, J.G.

    1981-07-01

    Bone scintigraphy and radiography were performed in seven children with back pain. Six of the children with radiographic evidence of a pars interarticularis defect also had abnormal scintigrams. Increased uptake of the bone imaging agent occurred at six of the ten sites of radiographic pars interarticularis defects, implying increased bone metabolic activity. However, the location of scintigraphic abnormalities did not correspond to the location of radiographic abnormalities in several cases. Measurements of absorbed radiation dose indicate that plain radiography, including oblique views where appropriate, has a lower absorbed radiation dose than scintigraphy or tomography and should be performed prior to these studies.

  18. Revascularization of femoral head ischemic necrosis with vascularized bone graft: A CT scan experimental study

    International Nuclear Information System (INIS)

    Gonzalez del Pino, J.; Knapp, K.; Gomez Castresana, F.; Benito, M.

    1990-01-01

    An ischemic necrosis of the femoral head was induced in 15 mongrel adult dogs using the technique described by Gartsman et al. Five weeks later, a free vascularized rib graft was transferred into the previously induced ischemic femoral head. High resolution computed tomographic scanning was used to evaluate revascularization 4, 8 and 12 weeks after grafting. The femoral head exhibited new vessel formation throughout the study. Arterial terminal branches arising from the rib graft medullary and periosteal circulations extended beyond the rib graft, entered the head, and reached the subchondral plate. Even where the rib graft did not replenish the central core of the head, there was vascular supply from the grafted bone's vascular tree. These results suggest that a free vascularized bone graft is able to revascularize an experimentally induced ischemic femoral head necrosis. (orig.)

  19. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Caricasulo, D. [Orthopaedics Dept., General Hospital of Bassano del Grappa (Italy); Borsato, N. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy)

    1996-10-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic {sup 99m}TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  20. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    International Nuclear Information System (INIS)

    Rubello, D.; Caricasulo, D.; Borsato, N.; Chierichetti, F.; Zanco, P.; Ferlin, G.

    1996-01-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic 99m TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  1. Radionuclide bone imaging in spondylolysis of the lumbar spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Gelfand, M.J.; Strife, J.L.; Kereiakes, J.G.

    1981-07-01

    Bone scintigraphy and radiography were performed in seven children with back pain. Six of the children with radiographic evidence of a pars interarticularis defect also had abnormal scintigrams. Increased uptake of the bone imaging agent occurred at six of the ten sites of radiographic pars interarticularis defects, implying increased bone metabolic activity. However, the location of scintigraphic abnormalities did not correspond to the location of radiographic abnormalities in several cases. Possible explanations for the discordant findings are: (a) normal bone metabolism at the site of an old spondylolysis and (b) radiographically inapparent stress fractures. Measurements of absorbed radiation dose indicate that plain radiography, including oblique views where appropriate, has a lower absorbed radiation dose than scintigraphy or tomography and should be performed prior to these studies.

  2. Radionuclide Tc-99m MDP imaging for diagnosis of bone tumour at ...

    African Journals Online (AJOL)

    F Hasford, J.H Amuasi, E.K Sosu, K Nani, T.A Sackey, M Boadu, I.K Wilson, E.C.K Addison ... breast, cervix and prostate. Breast, prostate and cervical cancers contribut-ed respectively to 34 %, 19 % and 18 % of the bone tumour cases, but only 3 % were diagnosed with osteoporo-sis (a relatively rare type of bone disease).

  3. Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

    International Nuclear Information System (INIS)

    Straten, Marcel van; Schaap, Michiel; Dijkshoorn, Marcel L.; Greuter, Marcel J.; Lugt, Aad van der; Krestin, Gabriel P.; Niessen, Wiro J.

    2011-01-01

    Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration

  4. [Stress fractures of the ribs with acute thoracic pain in a young woman, diagnosed by the bone scan].

    Science.gov (United States)

    Georgitzikis, Athanasios; Siopi, Dimitra; Doumas, Argyrios; Mitka, Ekaterini; Antoniadis, Antonios

    2010-01-01

    We report the unusual case of a 29 -year old woman with emotional instability who presented with acute onset chest pain after severe chronic cough. The chest X-ray and the serological tests were normal but the CT scanning, and the bone scanning revealed multiple bilateral rib stress fractures, caused by severe coughing and physical activity and worsened by the patient's emotional instability.

  5. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  6. Estimation of the skeletal burden of bone-seeking radionuclides from in vivo scintillation measurements of their content in the skull: contribution from radionuclides in the thoracic skeleton to in vivo measurement of activity in the lung

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    After the initiation of NaI(Tl), spectrometric methods for detecting photon-emitting radionuclides in man, it became evident that the high background rates in the low energy regions precluded in vivo measurement of many bone-seeking nuclides. To meet these needs a dual crystal, low energy sensitive NaI(Tl)-CsI(Tl) detector system was developed. To date this system, in combination with more routine bioassays, remains the optimum methodology for the determination of internal exposure to low energy, photon-emitting radionuclides. Since most occupational exposures occur by inhalation, internal deposits must be quantitated with these detectors placed over the lung area. Since many of the alpha-emitting nuclides are bone-seekers, the contribution of material which has been transported from the lung and deposited in the skeleton must be accounted for

  7. Radionuclide Tc-99m MDP Imaging for diagnosis of bone tumour at Korle-Bu Teaching Hospital (Ghana): an illustrative review

    International Nuclear Information System (INIS)

    Hasford, F.; Sosu, E.K.; Nani, K.; Sackey, T.A.; Boadu, M.; Wilson, I.K.; Addison, E.C.K.; Amuasi, J.H.

    2010-01-01

    Radioisotopes are used in diagnosing primary and metastatic bone tumours because of the high sensitivity. Diagnosing bone tumours using technetium methylene diphosphonate (Tc-99m MDP) on 9 randomly selected whole-body bone scans have been demonstrated by clinical studies of patients for illustrative review. Upon satisfactory testing of the e.cam (R) Single Photon Emission Computed Tomography at the Nuclear Medicine Department (Korle-Bu Teaching Hospital), scans of patients provided essential physiologic information about the sites of bone lesions and prognosis as shown by sequential changes in tracer uptake. The bone scintigrams were classified either as normal or pathologic. Of the 197 patients (91 males and 106 females) who underwent radioactive whole-body scans in the year 2006, the peak age at bone tumour detection was between 51 and 60 years. From qualitative analyses of the reported cases, 144 patients were diagnosed with bone tumours, but ∼ 17 % were found to be primary, while ∼ 83 % were metastatic in nature. The observation confirmed other published data that bone tumours with origin in the cells of bone are not prevalent compared to tumours that metastasize from other parts of the body, such as breast, cervix and prostate. Breast, prostate and cervical cancers contributed respectively to 34 %, 19 % and 18 % of the bone tumour cases, but only 3 % were diagnosed with osteoporosis (a relatively rare type of bone disease). (au)

  8. Physico chemical study of the uptake of some radionuclides by the human bone powder

    International Nuclear Information System (INIS)

    Mohamed, S.A.

    1989-01-01

    Human bone femurs were freed from flesh and marrow, crushed and ground to a grain size below 50 in diameter. Fat was extracted from one third of the powder (FFB). protein was extracted from the second third (PFB) and the third portion was without any treatment as raw bone powder (RB). Physical and chemical properties of bone powder such as density, chemical composition, calcium content, and nitrogen content were investigated. Experimental procedures followed two techniques: - Schweitzer and Nehls technique (164) where a large reaction vessel was used. - Harrison et al technique (90) where the batch system was used. Counting systems applied were : beta counting for 89 Sr and gamma counting for 60 Co and 6 5 Zn

  9. Radiation exposure to personnel involved in bone scans for horses with technetium 99m-diphosphonat

    International Nuclear Information System (INIS)

    Sommerfeld, Theresa Christine

    2016-01-01

    Key objective of this study has been the evaluation of radiation exposure of veterinarian personnel wearing dosimeters which were involved in equine scintigraphy. A survey, which was developed in parallel to this study, showed that personnel in equine horse clinics have often knowledge gaps about scintigraphy and the related radiation doses. The survey showed skepticism of the involved personnel towards the methods of bone scintigraphy as the impacts of expositions are barely known in common. The scintigraphic investigations and measurements were done at the horse clinic (department of surgery) in Giessen and were part of the routinely bone scanning of horses. A total of 33 bone scans were taken, covering either full- or half-body scintigraphies. Additional 10 bone scans covered measurements with and without the protection of a 0,5 mm lead-shield. The activity of involved personnel was monitored at four different positions: MP1 was associated with the position of the person preparing the radiopharmaceutical for injection, MP2 with the position at holding the horse during the bone scan, MP3 with the position at holding the horse's legs and to make sure that the horse was standing in the right position, MP4 with the position for the camera operator. Some more dose measurements were made from the horse body (MP5 and MP6) as well as in the control area (MP7). In order to analyze the patient's constitution, additional data like weight, size, body extent and length of the torso were additionally captured. The body data were collected to investigate exposure differences of rather big and heavy or small and thin horses. These data and the dosimeter at the horse body (MP5) enabled the correlation analysis between the horse body composition and the received dose rate of the personnel (MP2). MP1 received a mean dose of 11 μSv and a dose rate of 123 μSv/h, MP2 received 31 μSv for a whole-body and 23 μSv for a half-body bone scan. The dose rate of MP2 was 22 μSv/h. MP3 was

  10. Detection of soft tissue pathology on the blood pool phase of bone scans

    International Nuclear Information System (INIS)

    Raimondo, A.J.; Turner, H.A.; Kitchener, M.I.

    1999-01-01

    Full text: It is important to optimize information obtained from isotope bone scanning in musculoskeletal imaging. Although important at all times, it is especially imperative in the current climate of health services rationalization, capping of imaging expenditure and the promotion of newer modalities that are increasingly versatile and sensitive for imaging the musculoskeletal system. Careful attention must be paid to the blood flow and blood pool images, to visualize soft tissue as well as bony pathology. A series of cases and images will be presented that demonstrated blood pool pathology that was not appreciated on delayed imaging, or where reliance only on the delayed images would have led to an incorrect diagnosis. These include the detection of tendonitis, tenosynovitis, bursitis, muscle tears and soft tissue neoplasms, including neuromas. In cases where the bone scan cannot provide a definitive diagnosis, it will at least direct the referring clinician to the most appropriate confirmatory diagnostic imaging modality, thus reinforcing the value that isotope imaging provides in musculoskeletal medicine

  11. Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Li Qiang; Appelbaum, Daniel; Pu Yonglin; Doi, Kunio

    2007-01-01

    Bone scintigraphy is the most frequent examination among various diagnostic nuclear medicine procedures. It is a well-established imaging modality for the diagnosis of osseous metastasis and for monitoring osseous tumor response to chemotherapy and radiation therapy. Although the sensitivity of bone scan examinations for detection of bone abnormalities has been considered to be relatively high, it is time consuming to identify multiple lesions such as bone metastases of prostate and breast cancers. In addition, it is very difficult to detect subtle interval changes between two successive abnormal bone scans, because of variations in patient conditions, the accumulation of radioisotopes during each examination, and the image quality of gamma cameras. Therefore, we developed a new computer-aided diagnostic (CAD) scheme for the detection of interval changes in successive whole-body bone scans by use of a temporal subtraction image which was obtained with a nonlinear image-warping technique. We carried out 58 pairs of successive bone scans in which each scan included both posterior and anterior views. We determined 107 'gold-standard' interval changes among the 58 pairs based on the consensus of three radiologists. Our computerized scheme consisted of seven steps, i.e., initial image density normalization on each image, image matching for the paired images, temporal subtraction by use of the nonlinear image-warping technique, initial detection of interval changes by use of temporal-subtraction images, image feature extraction of candidates of interval changes, rule-based tests by use of 16 image features for removing some false positives, and display of the computer output for identified interval changes. One hundred seven gold standard interval changes included 71 hot lesions (uptake was increased compared with the previous scan, or there was new uptake in the current scan) and 36 cold lesions (uptake was decreased or disappeared) for anterior and posterior views. The

  12. Malignant pleural mesothelioma with heterologous osteoblastic differentiation: case report of the characteristic CT and bone scan findings

    International Nuclear Information System (INIS)

    Cho, Young Jun; Kim, Joung Sook; Kim, Ji Young; Choi, Soo Jeon; Choi, Sang Bong

    2008-01-01

    Malignant pleural mesothelioma is an uncommon neoplasm which is accompanied extremely rarely by osteoblastic heterologous elements. The CT manifestations of this tumor have been reported in several references. And, to our knowledge, only one case report provides a description of the bone scan findings. Here, we report the case of a rapidly progressing malignant pleural mesothelioma with heterologous osteoblastic elements. A CT scan reveals diffuse irregular pleural thickening and very coarse nodular calcifications along the right pleura and major fissure. A bone scan revealed an area of extensive increased radioactivity consistent with the pleural calcifications on the CT scan in the right hemithorax. A follow-up CT scan performed 40 days later suggests the presence of rapidly progressing nodular coarse calcifications

  13. Malignant pleural mesothelioma with heterologous osteoblastic differentiation: case report of the characteristic CT and bone scan findings

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Jun; Kim, Joung Sook; Kim, Ji Young; Choi, Soo Jeon; Choi, Sang Bong [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2008-06-15

    Malignant pleural mesothelioma is an uncommon neoplasm which is accompanied extremely rarely by osteoblastic heterologous elements. The CT manifestations of this tumor have been reported in several references. And, to our knowledge, only one case report provides a description of the bone scan findings. Here, we report the case of a rapidly progressing malignant pleural mesothelioma with heterologous osteoblastic elements. A CT scan reveals diffuse irregular pleural thickening and very coarse nodular calcifications along the right pleura and major fissure. A bone scan revealed an area of extensive increased radioactivity consistent with the pleural calcifications on the CT scan in the right hemithorax. A follow-up CT scan performed 40 days later suggests the presence of rapidly progressing nodular coarse calcifications.

  14. Differentiation of osteomyelitis and infarction in sickle-cell hemoglobinopathies using combined bone-marrow and gallium scanning

    International Nuclear Information System (INIS)

    Hatfield, M.K.; Kahn, C.E.; Ryan, J.W.; Martin, W.B.

    1986-01-01

    The clinical records and scintigrams of patients with sickle cell hemoglobinopathies in whom acute symptoms developed suggestive of possible osteomyelitis and who had undergone sequential Tc-99m bone marrow scans and gallium scintigraphy of the affected sites were reviewed. Osteomyelitis was correctly diagnosed in six of 18 cases when gallium was focally increased relative to a site of decreased or absent bone marrow activity. Of 12 episodes of infarction, both studies showed focally decreased activity in a concordant manner in 11. The remaining, false-positive study indicated slightly increased gallium in 11. The remaining, false-positive indicated slightly increased gallium concentration at a site of decreased bone marrow activity. Overall, a protocol of sequential Tc-99m bone marrow scans and gallium scintigraphy is an effective means of distinguishing osteomyelitis from infarction in patients with sickle cell hemoglobinopathies

  15. Wholebody and pinhole bone scan manifestations of reiter's syndorme: distribution pattern and specific and early signs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Chung, S. K.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Han, B. H.; Bahk, Y. W. [College of Medicine, Catholic Univ., Seoul (Korea, Republic of)

    1998-07-01

    We wish to describe the characteristics panoramic wholebody bone distribution, and specific and preradiographic pinhole bone scan signs of Reiter's syndrome(RS) featured by pauciarthritis and enthesopathies in and about weight-bearing joints of the lower extremities and axial bones. We analyzed 55 sets of wholebody and pinhole bone scintigraphs of 55 patients with RS. The population was 44 men and 11 women with age ranging from 15 to 52 yr (mean=29.3). The scintigraphy was performed 2-2.5 hr pi of Tc-99m-HDP using a single-head gamma camera with a LEHR collimator and a 4-mm pinhole collimator for the wholebody and pinhole scintigraphy, respectively. We found 223 lesions with increased tracer uptake in total. Wholebody scans showed asymmetric pauciarticular distribution in weight bearing joints and periarticular entheses in the lower extremities in 63.2% (calcaneus=24.2%, ankle=8.1%, tibia=8.1% and others). The sternum, sacroiliac joint and spine were involved in 8.5%, 5.8% and 4.5%, respectively. Pinhole scan portrayed many specific signs including the 'tear-drop' sign of paravertebral ossification. 'whiskers' sign of femoral osteophytes and 'knuckle bone' sign of sausage digit. Twenty-four lesions (10.8%) showed preradiogrpahic signs in symptomatic ehthesopathies mostly in the calcaneus and proximal tibia. Nine cases with calcaneal enthesopathies and four cases with proximal tibial enthesopathy without radiographic bone change showed intense tracer uptake. Wholebody and pinhole magnification scans were useful in studying RS. The asymmetric pauciarticular distribution in the weight-bearing bones with enthesopathies was characteristic. Pinhole scan portrayed many specific signs and was sensitive permitting accurate preradiographic diagnosis in many cases.

  16. Three-dimensional model of the skull and the cranial bones reconstructed from CT scans designed for rapid prototyping process.

    Science.gov (United States)

    Skrzat, Janusz; Spulber, Alexandru; Walocha, Jerzy

    This paper presents the effects of building mesh models of the human skull and the cranial bones from a series of CT-scans. With the aid of computer so ware, 3D reconstructions of the whole skull and segmented cranial bones were performed and visualized by surface rendering techniques. The article briefly discusses clinical and educational applications of 3D cranial models created using stereolitographic reproduction.

  17. The comparison between the prostatic specific antigen and the bone scan in the diagnosis of metastases in operating patients of prostatic cancer. Preliminary report

    International Nuclear Information System (INIS)

    Morales, R.; Cano P, R.; Mendoza P, G.; Pow S, M.

    1993-01-01

    To compare the value of prostatic specific antigen (PSA) with bone scan results, a study was conducted enrolling 25 prostatic adenocarcinoma patients, fulfilling the following criteria for inclusion: a) histological confirmation of diagnosis b) radical prostatectomy at least three months before bone scan as curative therapy c) at least one month between bone scan and PSA measurement. Fourteen cases were within normal ranges on both techniques. Eleven had metastases on bone scans, with PSA in normal range in five of them. The Spearman's ranks coefficient was rs=0,92, with alfa=0,01, accepting that both tecniques are comparable. (Authors). 10 refs., 1 tab., 2 figs

  18. Reproducibility of trabecular bone score with different scan modes using dual-energy X-ray absorptiometry: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Bandirali, Michele; Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Di Leo, Giovanni [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Pastor Lopez, Maria Juana; Ulivieri, Fabio M. [Servizio di Medicina Nucleare, Ospedale Maggiore, Mineralometria Ossea Computerizzata e Ambulatorio Malattie Metabolismo Minerale e Osseo, Milano (Italy); Mai, Alessandro [Universita degli Studi di Milano, Tecniche di Radiologia Medica, per Immagini e Radioterapia, Milano (Italy); Sardanelli, Francesco [Unita di Radiologia, IRCCS Policlinico San Donato, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2014-08-12

    The trabecular bone score (TBS) accounts for the bone microarchitecture and is calculated on dual-energy X-ray absorptiometry (DXA). We estimated the reproducibility of the TBS using different scan modes compared to the reproducibility bone mineral density (BMD). A spine phantom was used with a Hologic QDR-Discovery A densitometer. For each scan mode [fast array, array, high definition (HD)], 25 scans were automatically performed without phantom repositioning; a further 25 scans were performed with phantom repositioning. For each scan, the TBS was obtained. The coefficient of variation (CoV) was calculated as the ratio between standard deviation and mean; percent least significant change (LSC%) as 2.8 x CoV; reproducibility as the complement to 100 % of LSC%. Differences among scan modes were assessed using ANOVA. Without phantom repositioning, the mean TBS (mm{sup -1}) was: 1.352 (fast array), 1.321 (array), and 1.360 (HD); with phantom repositioning, it was 1.345, 1.332, and 1.362, respectively. Reproducibility of the TBS without phantom repositioning was 97.7 % (fast array), 98.3 % (array), and 98.2 % (HD); with phantom repositioning, it was 97.9 %, 98.7 %, and 98.4 %, respectively. LSC% was ≤2.26 %. Differences among scan modes were all statistically significant (p ≤ 0.019). Reproducibility of BMD was 99.1 % with all scan modes, while LSC% was from 0.86 % to 0.91 %. Reproducibility error of the TBS was 2-3-fold higher than that of BMD. Although statistically significant, differences in TBS among scan modes were within the highest LSC%. Thus, the three scan modes can be considered interchangeable. (orig.)

  19. Tooth enamel as a naturtal beta dosemeter for bone seeking radionuclides

    International Nuclear Information System (INIS)

    Wieser, A.; Petzoldt, G.

    1996-01-01

    EPR dosimetry was done on teeth from residents of villages along the Techa river, Southern Urals, Russia. The residents have a 90 Sr body burden due to massive releases of liquid nuclear waste into the Techa river in the early fifties. A long time after ingestion, strontium is only incorporated into the skeleton and dentine of the adults but not in tooth enamel. Tooth enamel therefore, is measuring the beta dose from the contaminated dentine. Based on experimental data of this study a first approximation of the ingestion dose coefficient of tooth enamel was found to be more than 5 times lower than the value given in ICRP 69 for the bone surface of the skeleton. A similar difference was found earlier for the dose absorbed in tooth enamel and dentine. The result of this study allows the supposition that that the metabolism of strontium is very very similar for tooth dentine and the skeleton. (author)

  20. An electrochemical approach for removal of radionuclidic contaminants of Eu from 153Sm for effective use in metastatic bone pain palliation.

    Science.gov (United States)

    Chakravarty, Rubel; Chakraborty, Sudipta; Khan, Mohammed Sahiralam; Ram, Ramu; Sarma, Haladhar Dev; Dash, Ashutosh

    2018-03-01

    Thermal neutron activation of 152 Sm [ 152 Sm(n,γ) 153 Sm] using natural or isotopically enriched (by 152 Sm) samarium target is the established route for production of 153 Sm used for preparation of 153 Sm-EDTMP for pain palliation in cancer patients with disseminated bone metastases. However, some long-lived radionuclidic contaminants of Eu, such as, 154 Eu (t ½ =8.6y) are also produced during the target activation process. This leads to detectable amount of Eu radionuclidic contaminants in patients' skeleton even years after administration with therapeutic doses of 153 Sm-EDTMP. Further, the presence of such contaminants in 153 Sm raises concerns related to radioactive waste management. The aim of the present study was to develop and demonstrate a viable method for large-scale purification of 153 Sm from radionuclidic contaminants of Eu. A radiochemical separation procedure adopting electroamalgamation approach has been critically evaluated. The influence of different experimental parameters for the quantitative removal radionuclidic contaminants of Eu from 153 Sm was investigated and optimized. The effectiveness of the method was demonstrated by purification of ~37 GBq of 153 Sm in several batches. As a proof of concept, 153 Sm-EDTMP was administered in normal Wistar rats and ex vivo γ-spectrometry of bone samples were carried out. After carrying out the electrolysis under the optimized conditions, the radionuclidic contaminants of Eu could not be detected in purified 153 Sm solution by γ-spectrometry. The overall yield of 153 Sm obtained after the purification process was >85%. The reliability of this approach was amply demonstrated in several batches, wherein the performance remained consistent. Ex vivo γ-spectrometry of bone samples of Wistar rats administered with 153 Sm-EDTMP (prepared using electrochemically purified 153 Sm) did not show photo peaks corresponding to radionuclidic contaminants of Eu. A viable electrochemical strategy for the large

  1. Dose to the metaphyseal growth complexes in children undergoing /sup 99m/Tc-EHDP bone scans

    International Nuclear Information System (INIS)

    Thomas, S.R.; Gelfand, M.J.; Kerelakes, J.G.; Ascoli, F.A.; Maxon, H.R.; Saenger, E.L.; Feller, P.A.; Sodd, V.J.; Paras, P.

    1978-01-01

    The spatial and temporal distribution of radionuclides in children may differ greatly from that accepted for adults. Following injection of a bone-seeking agent (/sup 99m/Tc-EHDP), radioactivity in the metaphyseal growth complexes of the distal femur and proximal tibia was quantitated in a series of children 4 to 16 years of age, using a gamma camera/computer system. The dose to the growth plate was found to range from 0.8 to 4.7 rads when adjusted to an administered activity of 200 μci/kg, compared to approximately 0.6 rad to the adult skeleton for a corresponding study

  2. Radionuclide imaging of soft tissue neoplasms

    International Nuclear Information System (INIS)

    Chew, F.S.; Hudson, T.M.; Enneking, W.F.

    1981-01-01

    Two classes of radiopharmaceuticals may be used for imaging tumors of the musculoskeletal system. The first is comprised of soft tissue or tumor specific agents such as gallium-67, bleomycin, and radionuclide-labeled antibodies, which may be useful for detecting and localizing these tumors. The other class of tracer is comprised of those with avidity for bone. The 99mTc-labeled-phosphate skeletal imaging compounds have been found to localize in a variety of soft tissue lesions, including benign and malignant tumors. In 1972, Enneking began to include bone scans in the preoperative evaluation of soft tissue masses. Later, he and his associates reported that these scans were useful in planning operative treatment of sarcomas by detecting involvement of bone by the tumors. Nearly all malignant soft tissue tumors take up bone-seeking radiopharmaceuticals, and bone involvement was indicated in two-thirds of the scans we reviewed. About half of benign soft tissue lesions had normal scans, but the other half showed uptake within the lesion and a few also showed bone involvement. Careful, thorough imaging technique is essential to proper evaluation. Multiple, high-resolution static gamma camera images in different projections are necessary to adequately demonstrate the presence or absence of soft tissue abnormality and to define the precise relationship of the tumor to the adjacent bone

  3. Comparison of gated radionuclide scans and chest radiographs. Assessment of left ventricular impairment in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Reinke, D B; Makey, D G; Shafer, R B

    1980-03-01

    Diagnostic efficacy of gated cardiac blood pool imaging was studied in 41 consecutive patients with LV ejection fractions (LVEF) less than or equal to 0.50. Eighty percent of patients were receiving therapy for LV failure at the time of the study. All patients had documented coronary-artery disease (CAD). Chest x-ray films were interpreted blindly by a senior radiologist. Cardiothoracic ratio of less than or equal to 0.50 was recorded as normal. Radionuclide assessment of LV function contributes importantly to the diagnostic and screening value of chest x-ray films. Patients with coronary disease and clinical evidence of heart failure should have radioisotopic studies even if chest x-ray film findings are normal. In patients with coronary artery disease and enlarged LV on chest films, radionuclide study of left ventricular performance aids in defining LV impairment, and in the prognostication of subsequent clinical course.

  4. Radionuclide patterns of femoral head disease

    Energy Technology Data Exchange (ETDEWEB)

    Webber, M M; Wagner, J; Cragin, M D [California Univ., Los Angeles (USA). Dept. of Radiological Sciences

    1977-12-01

    The pattern of uptake of bone marrow specific radio-sup(99m)Tc sulfur colloid and the pattern of uptake of bone mineral specific radio-sup(99m)Tc pryophosphate may be valuable in assessing bone vascularity in diseases suspected of causing impaired blood supply, or indicate the presence of reactive bone formation. The low energy of the technetium label has been shown to be superior to /sup 18/F and /sup 85/Sr, and leads to greater imaging detail on the scans. Femoral head scanning with mineral and/or marrow specific radionuclides offers the clinician a method of evaluating the status of the femoral head and possibly an early diagnosis of avascular necrosis before roentgenographic changes occur. This study, which reports on a 5-year experience using radionuclide scanning to assess femoral head vascularity, begins with baseline or normal studies followed by variations of the normal pattern. Typical scan patterns of hip pathology described above are also presented.

  5. Cancer patients undertaking bone scans in a department of Nuclear Medicine have significant stress related to the examination

    International Nuclear Information System (INIS)

    Sioka, C.; Manetou, M.; Dimakopoulos, N.; Christidi, S.; Kouraklis, G.

    2005-01-01

    Bone scanning is a standard screening procedure for evaluation of metastases in cancer patient. In addition to the staging procedures, bone scan is a valuable test for deciding palliative therapeutic options in selected patients. The aim of this study was to investigate if patients with cancer who were undertaking routine bone scans had any stress related to the test. We asked 83 consecutive patients with various types of cancer if they had anxiety just prior to undergoing the test. Overall, we found that 53 (64%) patients had increased anxiety related to the examination and 30 (36%) patients did not. Among the 53 patients who were anxious about the bone scan, 32 were concerned about the results of the examination, 13 worried about the effects of the radiation, 4 were anxious for both results/radiation, and 4 patients had stress but could not specify the reason. Among the 32 patients who were concerned about the results of the examination, 15 were having their first bone scans, while 17 had already undergone the procedure before. Among the 13 patients who were mainly concerned about the risks of the radiation exposure during the test, 9 were having bone scans for the first time. Out of the 4 patients who feared both the results and radiation, 3 were having bone scans for the first time and 1 had it for several times. Finally, out of the 4 patients who had anxiety about the test but could not identify the reason, 3 were having bone scans for the first time and one had the test before but was claustrophobic. Our findings indicate that most patients (64%) with cancer who underwent a routine bone scan to check for metastatic disease had intense stress related either to the results or the side effects of the examination. However, there were more patients who were concerned about the results of the test rather than the effects of radiation. Among the patients who feared the effects of radioactivity most were having the test for the first time. A previous study in a

  6. Investigation of the vestibular aqueduct and the cochlear aqueduct by temboral bone CT scan

    International Nuclear Information System (INIS)

    Shimizu, Ryuichi; Kamei, Tamio; Ito, Fumihide

    1984-01-01

    The visualization of the vestibular aqueduct and the cochlear aqueduct was investigated by temporal bone CT scan. The vestibular aqueduct was visualized in horizontal CT sections of 70.0% of normal ears, 61.5% of ears with chronic otitis media, 58.3% of ears with combined hearing impairment, 66.7% of ears in cases of sudden deafness, 70.8% of ears of patients with sensorineural hearing impairment without sudden deafness, 71.4% of cases of vertigo without hearing impairment and 12.5% of both diseased and contralateral ears of patients with Meniere's disease. Only in Meniere's disease was the vestibular aqueduct less visible in the diseased than in the normal ear (P<0.01). The cochlear aqueduct was visible in coronal sections of 50.0% of normal ears, 76.9% of those with chronic otitis media, 58.3% of those with combined hearing impairment, 66.7% of those with sudden deafness 41.7% of those with sensorineural hearing impairment without sudden deafness, 50.0% of the diseased ears of patients with Meniere's disease, 37.5% of the contralateral ears of those with Meniere's disease and 64.3% of those with vertigo without hearing impairment. Although the cochlear aqueduct was thus highly demonstrable in patients with chronic otitis media or sudden deafness, the difference between the percentage of visualization in these diseased and in normal ears was not statistically significant. (author)

  7. Selective heating of soft tissue-bone interfaces during scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Hynynen, K.; De Young, D.; Roemer, R.; Kundrat, M.

    1987-01-01

    Bone heating has been a frequent problem with clinical hyperthermia treatments induced by plane ultrasonic transducers. In this study, detailed temperature distributions were measured in dogs' (5 dogs) thigh muscles and bone in vivo while focussed ultrasound was applied to elevate the muscle temperature next to the bone. Significantly higher temperature elevations were measured at the bone surface than in the target volume in front of the bone. The temperature distribution was sharp decreasing fast inside the bone and also in front of it. By using more sharply focussed and multiple beams the temperature elevation at the bone surface was reduced and by suitable choice of the distance between the bone surface and the acoustical focus almost uniform temperature could be induced in the overlying muscle tissue from the surface down to the bone - the bone surface being in the same temperature as the muscle. Similar result was obtained by using single, higher frequency focussed beam (3.58 MHz). Also the utilization of nonlinear ultrasonic propagation appeared to reduce bone heating. The results showed that by carefully planning ultrasound hyperthermia treatments, tissues close to bone can be heated without extensive temperature elevation at bone surface

  8. Abnormal extraosseous activity in both lungs and stomach in pre-transplant 99mTc-MDP bone scan disappearing after renal transplant

    International Nuclear Information System (INIS)

    Sonavane, Sunita Tarsarya; Marwah, Atul; Jaiswar, Rajnath; Shah, Hardik

    2013-01-01

    A chronic kidney disease male patient presenting with bone pains, fever, weakness, and clinically ascites was subjected to four technetium-99m-methylene diphosphonate ( 99m Tc-MDP) bone scans, two before renal transplant and two after renal transplants. Pretransplant bone scan revealed metabolic bone disease with focal insufficiency fractures. Marked extraosseous activity in both lungs and stomach was also visualized. On regular hemodialysis (HD) after 4 months, repeat pretransplant bone scan showed persistent uptake in lungs and stomach, representing altered calcium metabolism with microcalcifications. He underwent human leukocyte antigen (HLA) matched live donor renal transplantation, started on immune-suppression and steroids. Posttransplant bone scan at 20 days revealed no definite interval change, but bone scan performed approximately 17 months posttransplant showed resolving metabolic bone disease and the tracer uptake in the lungs and stomach was no more visualized. Patient clinically followed-up until the date (February 2013) is asymptomatic with serum creatinine of 1.5 mg/dl, no bone scan done. (author)

  9. A histomorphometric and scanning electron microscopy study of human condylar cartilage and bone tissue changes in relation to age

    DEFF Research Database (Denmark)

    Paulsen, Hans Ulrik; Thomsen, J.S.; Hougen, Hans Petter

    1999-01-01

    To determine the possibility for adaptive growth in human condyles, quantifying the thickness of fibrocartilage and the constitution of cells with potential activity, the trabecular bone volume, and the structural parameter: marrow space star volume in a larger sample of human autopsy condyles....... EXPERIMENTAL SETTING AND DESIGN: A histomorphometric and scanning electron microscopic analysis of cartilage characteristics and bone remodelling activity. The Departments of Orthodontics and Cell Biology at Aarhus University, Denmark. An autopsy sample of condyles from 20 individuals, 18-31 years of age...

  10. Clinical significance of bone scintigraphy and computerized tomography (CT scan) in the evaluation of renal osteodystrophy in haemodialysed and non-haemodialysed patients

    International Nuclear Information System (INIS)

    Yatsuboshi, Motohiko

    1978-01-01

    For the evaluation of renal osteodystophy in both haemodialysed and non-haemodialysed patients, bone scintigraphy and computerized tomography (CT) scan were performed. Twenty-six patients with chronic renal failure were objectives of the study. For the control study of CT scan, patients with brain tumor without renal disease were selected. Bone scan was performed approximately 3 hours after sup(99m) Tc-EHDP (ethane-1-hydroxy-1, 1-diphosphonate) administration. The numericals which were printed out from CT scanner were analyzed in the area of frontal bone. The number of positive group was 9 and that of negative was 17. Positive group in non-haemodialysed patients showed lower serum calcium level and creatinine clearance and higher serum levels of inorganic phosphate and BUN compared with those of negative group. Positive scan group showed longer duration of dialysis and higher serum levels of parathyroid hormone and alkaline phosphatase than those of negative group. Frequency of abnormal findings detected by bone scan was higher than that elicited by roentgenographic examination. CT number of positive scan group was lower than that of negative group or control group. CT number in patients with subperiosteal resorption of phalanx and abnormal findings of calvarium was lower than that of patients without such roentgenographic abnormalities. These findings indicate that bone scan is useful in detecting bone changes of secondary hyperparathyroidism in chronic renal failure. CT scan could also help to estimate the decrease of bone density of calvarium in chronic renal failure. (author)

  11. Comparison of [68Ga]Ga-PSMA-11 PET/CT with [18F]NaF PET/CT in the evaluation of bone metastases in metastatic prostate cancer patients prior to radionuclide therapy.

    Science.gov (United States)

    Uprimny, Christian; Svirydenka, Anna; Fritz, Josef; Kroiss, Alexander Stephan; Nilica, Bernhard; Decristoforo, Clemens; Haubner, Roland; von Guggenberg, Elisabeth; Buxbaum, Sabine; Horninger, Wolfgang; Virgolini, Irene Johanna

    2018-05-16

    The purpose of this study was to investigate the diagnostic performance of 68 Ga-PSMA-11 PET/CT in the evaluation of bone metastases in metastatic prostate cancer (PC) patients scheduled for radionuclide therapy in comparison to [ 18 F]sodium fluoride ( 18 F-NaF) PET/CT. Sixteen metastatic PC patients with known skeletal metastases, who underwent both 68 Ga-PSMA-11 PET/CT and 18 F-NaF PET/CT for assessment of metastatic burden prior to radionuclide therapy, were analysed retrospectively. The performance of both tracers was calculated on a lesion-based comparison. Intensity of tracer accumulation of pathologic bone lesions on 18 F-NaF PET and 68 Ga-PSMA-11 PET was measured with maximum standardized uptake values (SUV max ) and compared to background activity of normal bone. In addition, SUV max values of PET-positive bone lesions were analysed with respect to morphologic characteristics on CT. Bone metastases were either confirmed by CT or follow-up PET scan. In contrast to 468 PET-positive lesions suggestive of bone metastases on 18 F-NaF PET, only 351 of the lesions were also judged positive on 68 Ga-PSMA-11 PET (75.0%). Intensity of tracer accumulation of pathologic skeletal lesions was significantly higher on 18 F-NaF PET compared to 68 Ga-PSMA-11 PET, showing a median SUV max of 27.0 and 6.0, respectively (p PET, with a median SUV max of 1.0 in comparison to 2.7 on 18 F-NaF PET; however, tumour to background ratio was significantly higher on 18 F-NaF PET (9.8 versus 5.9 on 68 Ga-PSMA-11 PET; p = 0.042). Based on morphologic lesion characterisation on CT, 18 F-NaF PET revealed median SUV max values of 23.6 for osteosclerotic, 35.0 for osteolytic, and 19.0 for lesions not visible on CT, whereas on 68 Ga-PSMA-11 PET median SUV max values of 5.0 in osteosclerotic, 29.5 in osteolytic, and 7.5 in lesions not seen on CT were measured. Intensity of tracer accumulation between 18 F-NaF PET and 68 Ga-PSMA-11 PET was significantly higher in osteosclerotic (p

  12. Detection of bone metastases in breast cancer patients in the PET/CT era: Do we still need the bone scan?

    Science.gov (United States)

    Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F

    2016-01-01

    To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  13. Value of whole body bone scan in the pre-operative assessment in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, P [Oerebro Regional Hospital (Sweden). Dept. of Oncology; Vikterloef, K J; Beckman, K W [Oerebro Regional Hospital (Sweden). Dept. of Radiation Physics; Rydman, H; Blom, O [Oerebro Regional Hospital (Sweden). Dept. of Diagnostic Radiology

    1979-01-01

    In 126 patients with primary breast cancer a patient moving whole-body bone scan was performed when they first presented. None of the patients in stage I had an evidence of skeletal metastases. Two patients (3%) of 62 in stage II and 4 patients (17%) in stage III had evidence of skeletal metastases. It appears that whole-body scanning is the most accurate, sensitive and convenient method of detecting osseous metastases and of staging breast cancer. This investigation should be carried out pre-operatively. Detection of early asymptomatic bony metastases will provide a better planning of treatment with rational approach.

  14. Correlation between bone scan findings and serum PSA level in prostate cancer patients in Bangladesh: both newly diagnosed and hormonally treated cases

    International Nuclear Information System (INIS)

    Yasmeen, S.; Nasreen, F.; Kabir, M.F.

    2007-01-01

    Full text: The objective of the current study was to determine whether pre- treatment serum prostate specific antigen (PSA) levels can identify a group with low probability of osseous metastases and safely eliminate the need for bone scan as a routine part of the staging evaluation in Bangladeshi patients with newly diagnosed prostate carcinoma. Also, to find out a cut off value for serum PSA level for predicting positive bone scan in newly diagnosed Bangladeshi prostate cancer patients and to assess the role of PSA level in hormonally treated cases. Prostate cancer most commonly metastasizes to the bone. Bone scintigraphy is one of the best methods in detecting bone metastases, assessing the progression of the disease and response to therapy. For more than 30 yrs it has been known that bone scintigraphy is more sensitive than radiographic, clinical evaluation or chemical markers such as alkaline phosphatase or acid phosphatase in detection of early osseous metastatic prostate cancer. The introduction of PSA has dramatically changed the management of prostate cancer. Serum PSA level has proven to be a useful serum marker for detection of metastatic prostate cancer and it provides the best overall correlation. It also has considerable impact on bone scanning. Of special significance is the fact that patients who have a low PSA level in previously untreated carcinoma of prostate are extremely unlikely to have positive findings on a bone scan for metastases. The picture is different in patients who has received and responded to hormonal therapy. Bone scintigraphy appears to be extremely useful in patients whose PSA level begins to rise after surgical procedure. Patients, who were on anti- androgen therapy, even though they had visible metastatic disease on bone scans, had normal level of PSA Patients and methods: A total of 390 cases were studied. Some (n=242) were newly diagnosed without having any specific treatment other than surgery. Others (n=148) were old cases

  15. Bone scanning with /sup 99m/Tc phosphate to assess condylar hyperplasia. Report of two cases

    International Nuclear Information System (INIS)

    Matteson, S.R.; Proffit, W.R.; Terry, B.C.; Staab, E.V.; Burkes, E.J. Jr.

    1985-01-01

    Condylar hyperplasia poses a problem in planning treatment because it is a self-limiting process for some but not all patients. Continued growth creates a progressive deformity that requires condylectomy, whereas an enlarged condyle can be left in place after hyperplastic growth ceases, even if ramus surgery is needed to correct asymmetry. Bone scan with /sup 99m/Tc phosphate can be used to assist in making the differential diagnosis. In the two patients reported here, abnormal metabolic activity revealed by bone scans supported clinical and historical evidence that the condylar hyperplasia was active and required surgical correction, including condylectomy. The two cases demonstrate different approaches to postsurgical orthodontic treatment, depending on the amount of normal growth expected

  16. Septal endocarditis, bone infection and severe leg ischemia detected in Tc-99m labelled monoclonal anti granulocyte scan

    International Nuclear Information System (INIS)

    Bechelaghem, A.I; Habbeche, M; Benlabgaa, R; Ghedbane, IE; Hanzal, A; Khelifa, A; Mechcken, F; Bourezak, SE; Bouyoucef, SE

    2006-01-01

    Patient 28 years old has continued to have a persistent fever (39.2 O C), despite ten days treatment by specific antibiotics for bacterial endocarditis associated to a recent claudication of the right lower leg. The persistent fever has motivated a 99mTc-labelled monoclonal anti granulocyte scan which has showed an important uptake in the myocardial septum, and other infection locations in temporal bone and in right tibial arteries. Two days after, a nanocolloids-99mTc WBS showed no uptake in the heart area, a total absence of uptake of the nanocolloids in the bone marrow of right tibia b and cranial SPECT views confirmed the infectious site in the right temporal bone. New antibiotic strategy was adopted successfully associated with surgical amputation of the right lower leg (au)

  17. Association of non-traumatic complex regional pain syndrome with adenocarcinoma lung on 99mTc-MDP bone scan

    International Nuclear Information System (INIS)

    Damle, Nishikant A.; Tripathi, Madhavi; Singhal, Abhinav; Bal, Chandrasekhar; Praveen Kumar; Kandasamy, Devasenathipathi; Jana, Manisha

    2012-01-01

    Complex regional pain syndrome (CRPS) is usually associated with trauma. Rarely, it may be seen in association with malignancies. We present here the bone scan and X-ray findings in the case of a 56-year-male-patient with adenocarcinoma lung who also had non-traumatic CRPS without involvement of the stellate ganglion. The case highlights the fact that spontaneous development of reflex sympathetic dystrophy may be associated with a neoplastic etiology. (author)

  18. The combined effect of two different bone-seeking radionuclides on the induction of osteosarcomas in mice

    International Nuclear Information System (INIS)

    Mueller, W.A.; Luz, A.; Linzner, U.; Murray, A.B.

    1991-01-01

    The effect of injection of 1.85kBq/kg of the long-lived radionuclide 227 Ac on the induction of osteosarcomas in female NMRI-mice by different dose levels of the short-lived radionuclide 227 Th (18.5, 74, and 185 kBq/kg), of the short-lived radionuclide 224 Ra (18.5 kBq/kg and 185 kBq/kg) and of the short-lived β-emitter 177 Lu (100 MBq/kg and 200 MBq/kg) was investigated. The results showed in all cases that combined incorporation of two radionuclides at the levels of radioactivity studied has a lower biological effect than the sum of the effects of the components administered singly. (author)

  19. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P histogram equalization technique in combination with some other postprocessing technique is useful.

  20. Liver metastases of breast carcinoma detected on /sup 99m/Tc-methylene diphosphonate bone scan

    International Nuclear Information System (INIS)

    Baumert, J.E.; Lantieri, R.L.; Horning, S.; McDougall, I.R.

    1980-01-01

    The accumulation of bone-seeking radiopharmaceuticals has been reported in liver metastases from colon carcinoma and oat cell carcinoma of the lung. Two patients with breast carcinoma in whom hepatic metastases were visualized on /sup 99m/Tc-methylene diphosphonate bone images are described. This has not been previously reported

  1. Template-based automatic extraction of the joint space of foot bones from CT scan

    Science.gov (United States)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  2. Difference in bone mineral density score on dual Xray absorptiometry scan among ethnic groups of Karachi, Pakistan

    International Nuclear Information System (INIS)

    Shaikh, S.A.; Iqbal, J.; Faisal, L.; Islam, Z.U.; Ajmal, R.

    2017-01-01

    To determine the bone mineral density (BMD) scores on Dual energy X ray absorptiometry (DEXA) scan in individuals of different ethnic groups among local population of Karachi, Pakistan. Methodology: This cross sectional study was conducted in Departments of Anatomy and Radiology, Liaquat National Hospital and Medical College Karachi, from June 2016 to March 2017. The data were collected from the patients belonging to different ethnic groups, who were referred for DEXA scan and entered on structured proforma. SPSS 21 was used for data analysis. Results: Out of 232 patients, 206 were females and 26 were males with mean age of 59.6+-10.06 years. Majority of patients were resident of Karachi and belonging to Urdu speaking ethnic group. Mean BMI of patients was 29.3 6.69 and most of patients with osteoporosis were preobese and obese with BMI >25. The relationship of BMD with different ethnic groups showed statistically significant difference where Baloch had high incidence of osteoporosis of forearm and lumbar spine while Sindhi and Pathan had osteoporosis of hip. Conclusion: There is significant difference in BMD score on DEXA scan among different ethnic groups of Karachi. This information can help clinicians advise patients for timely DEXA scan and earlier use of bone preservation treatment. (author)

  3. Comparison of macroscopic and microscopic (stereomicroscopy and scanning electron microscopy) features of bone lesions due to hatchet hacking trauma.

    Science.gov (United States)

    Nogueira, Luísa; Quatrehomme, Gérald; Bertrand, Marie-France; Rallon, Christophe; Ceinos, Romain; du Jardin, Philippe; Adalian, Pascal; Alunni, Véronique

    2017-03-01

    This experimental study examined the lesions produced by a hatchet on human bones (tibiae). A total of 30 lesions were produced and examined macroscopically (naked eye) and by stereomicroscopy. 13 of them were also analyzed using scanning electron microscopy. The general shape of the lesion, both edges, both walls, the kerf floor and the extremities were described. The length and maximum width of the lesions were also recorded. The microscopic analysis of the lesions led to the description of a sharp-blunt mechanism. Specific criteria were identified (lateral pushing back, fragmentation of the upraising, fossa dug laterally to the edge and vertical striae) enabling the forensic expert to conclude that a hacking instrument was used. These criteria are easily identifiable using scanning electron microscopy, but can also be observed with stereomicroscopy. Overall, lateral pushing back and vertical striae visible using stereomicroscopy and scanning electron microscopy signal the use of a hacking tool.

  4. Radionuclide body function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1983-01-01

    A transverse radionuclide scan field imaging apparatus is claimed. It comprises: a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; means for rotating the array about the scan field and means for imparting travel to the collimators

  5. Radionuclide transfer

    International Nuclear Information System (INIS)

    Gerber, G.B.

    1993-01-01

    The research project described here had the aim to obtain further information on the transfer of nuclides during pregnancy and lactation. The tests were carried out in mini-pigs and rats receiving unchanging doses of radionuclides with the food. The following findings were revealed for the elements examined: Fe, Se, Cs and Zn were characterized by very high transfer levels in the mother, infant and foetus. A substantial uptake by the mother alone was observed for Co, Ag and Mn. The uptake by the foetus and infant here was 1 to 10 times lower. A preferential concentration in certain tissues was seen for Sr and Tc; the thyroid levels of Tc were about equally high in mothers and infants, while Sr showed less accumulation in the maternal bone. The lanthanide group of substances (Ce, Eu and Gd as well as Y and Ru) were only taken up to a very limited extent. The uptake of the examined radionuclides (Fe, Co, Ag, Ce) with the food ingested was found here to be ten times greater in rats as compared to mini-pigs. This showed that great caution must be observed, if the behaviour of radionuclides in man is extrapolated from relevant data obtained in rodents. (orig./MG) [de

  6. Morphobiochemical diagnosis of acute trabecular microfractures using gamma correction Tc-99m HDP pinhole bone scan with histopathological verification.

    Science.gov (United States)

    Bahk, Yong-Whee; Hwang, Seok-Ha; Lee, U-Young; Chung, Yong-An; Jung, Joo-Young; Jeong, Hyeonseok S

    2017-11-01

    We prospectively performed gamma correction pinhole bone scan (GCPBS) and histopathologic verification study to make simultaneous morphobiochemical diagnosis of trabecular microfractures (TMF) occurred in the femoral head as a part of femoral neck fracture.Materials consisted of surgical specimens of the femoral head in 6 consecutive patients. The specimens were imaged using Tc-99m hydroxymethylene diphosphonate (HDP) pinhole scan and processed by the gamma correction. After cleansing with 10% formalin solution, injured specimen surface was observed using a surgical microscope to record TMF. Morphological findings shown in the photograph, naive pinhole bone scan, GCPBS, and hematoxylin-eosin (H&E) stain of the specimen were reciprocally correlated for histological verification and the usefulness of suppression and enhancement of Tc-99m HDP uptake was biochemically investigated in TMF and edema and hemorrhage using gamma correction.On the one hand, GCPBS was able to depict the calcifying calluses in TMF with enhanced Tc-99m HDP uptake. They were pinpointed, speckled, round, ovoid, rod-like, geographic, and crushed in shape. The smallest callus measured was 0.23 mm in this series. On the other hand, GCPBS biochemically was able to discern the calluses with enhanced high Tc-99m HDP uptake from the normal and edema dipped and hemorrhage irritated trabeculae with washed out uptake.Morphobiochemically, GCPBS can clearly depict microfractures in the femoral head produced by femoral neck fracture. It discerns the microcalluses with enhanced Tc-99m HDP uptake from the intact and edema dipped and hemorrhage irritated trabeculae with suppressed washed out Tc-99m HDP uptake. Both conventional pinhole bone scan and gamma correction are useful imaging means to specifically diagnose the microcalluses naturally formed in TMF.

  7. Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration...

  8. The role of bone scanning, gallium and indium imaging in infection

    International Nuclear Information System (INIS)

    Mido, K.; Navarro, D.A.; Segall, G.M.; McDougall, I.R.

    1987-01-01

    Nuclear medicine studies have considerable value in diagnosing infectious conditions in the skeleton. In this chapter the authors discuss acute infections of bone and joints separately. The section on acute osteomyelitis covers radiopharmaceuticals, methods, experimental models and the results of clinical series. Acute infections of joints is discussed with attention to radiopharmaceuticals, methods and results. The diagnosis of acute infection is prosthetic joints is treated separately. The evaluation of chronic bone infections is described briefly

  9. Bone Scan in Detection of Biological Activity in Nonhypertrophic Fracture Nonunion

    OpenAIRE

    Gandhi, Sunny J.; Rabadiya, Bhavdeep

    2017-01-01

    Biological activity of the fracture site is very important factor in treatment planning of fracture nonunion. If no biological activity is detected, then an autologous bone graft can be supplemented or osteogenic supplementations, such as bone morphogenetic protein is given. If biological activity is present, then secure fixation is sufficient to achieve bony union. Biological activity of nonunions is usually assessed by conventional radiographs. The presence of callus formation is usually as...

  10. Symmetric visualization of the femoral heads in reticuloendothelial bone marrow scanning in adults

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Hoer, G

    1983-03-01

    Two hundred and twenty seven consecutive patients of either sex aged 15-84 suffering from various benign and malignant disorders were studied by sup(99m)Tc-HSA-MM reticuloendothelial bone marrow scintigraphy. In all patients, symmetric findings concerning visualization or nonvisualization of the femoral heads could be seen. Femoral heads were clearly visualized in 48%, nonvisualized in 43%, and equivocally visualized in 9%. In patients with clearly visualized femoral heads, the bone marrow showed peripheral extension in 81%, whereas in patients with nonvisualized femoral heads, bone marrow extension was observed in only 42%. There was a correlation between the degree of bone marrow extension and the ability to visualize femoral heads. There was no obvious difference between males and females, nor patients with various diseases or treatments, amongst nor between different age groups. Two hypotheses are suggested to explain the correspondence between presence of bone marrow tissue in the femoral heads and peripheral extension of the bone marrow organ. Nonvisualization of the femoral heads alone is insufficient to establish the diagnosis of avascular necrosis.

  11. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans,

  12. Development of a Nomogram Model Predicting Current Bone Scan Positivity in Patients Treated with Androgen-Deprivation Therapy for Prostate Cancer

    Science.gov (United States)

    Gotto, Geoffrey T.; Yu, Changhong; Bernstein, Melanie; Eastham, James A.; Kattan, Michael W.

    2014-01-01

    Purpose: To develop a nomogram predictive of current bone scan positivity in patients receiving androgen-deprivation therapy (ADT) for advanced prostate cancer; to augment clinical judgment and highlight patients in need of additional imaging investigations. Materials and methods: A retrospective chart review of bone scan records (conventional 99mTc-scintigraphy) of 1,293 patients who received ADT at the Memorial Sloan-Kettering Cancer Center from 2000 to 2011. Multivariable logistic regression analysis was used to identify variables suitable for inclusion in the nomogram. The probability of current bone scan positivity was determined using these variables and the predictive accuracy of the nomogram was quantified by concordance index. Results: In total, 2,681 bone scan records were analyzed and 636 patients had a positive result. Overall, the median pre-scan prostate-specific antigen (PSA) level was 2.4 ng/ml; median PSA doubling time (PSADT) was 5.8 months. At the time of a positive scan, median PSA level was 8.2 ng/ml; 53% of patients had PSA <10 ng/ml; median PSADT was 4.0 months. Five variables were included in the nomogram: number of previous negative bone scans after initiating ADT, PSA level, Gleason grade sum, and history of radical prostatectomy and radiotherapy. A concordance index value of 0.721 was calculated for the nomogram. This was a retrospective study based on limited data in patients treated in a large cancer center who underwent conventional 99mTc bone scans, which themselves have inherent limitations. Conclusion: This is the first nomogram to predict current bone scan positivity in ADT-treated prostate cancer patients, providing high predictive accuracy. PMID:25386410

  13. Development of a nomogram model predicting current bone scan positivity in patients treated with androgen-deprivation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Michael eKattan

    2014-10-01

    Full Text Available Purpose: To develop a nomogram predictive of current bone scan positivity in patients receiving androgen-deprivation therapy (ADT for advanced prostate cancer; to augment clinical judgment and highlight patients in need of additional imaging investigations.Materials and Methods: A retrospective chart review of bone scan records (conventional 99mTc-scintigraphy of 1,293 patients who received ADT at the Memorial Sloan-Kettering Cancer Center from 2000 to 2011. Multivariable logistic regression analysis was used to identify variables suitable for inclusion in the nomogram. The probability of current bone scan positivity was determined using these variables and the predictive accuracy of the nomogram was quantified by concordance index.Results: In total, 2,681 bone scan records were analyzed and 636 patients had a positive result. Overall, the median pre-scan prostate-specific antigen (PSA level was 2.4 ng/ml; median PSA doubling time (PSADT was 5.8 months. At the time of a positive scan, median PSA level was 8.2 ng/ml; 53% of patients had PSA <10 ng/ml; median PSADT was 4.0 months. Five variables were included in the nomogram: number of previous negative bone scans after initiating ADT, PSA level, Gleason grade sum, and history of radical prostatectomy and radiotherapy. A concordance index value of 0.721 was calculated for the nomogram. This was a retrospective study based on limited data in patients treated in a large cancer centre who underwent conventional 99mTc bone scans, which themselves have inherent limitations. Conclusions: This is the first nomogram to predict current bone scan positivity in ADT-treated prostate cancer patients, providing high predictive accuracy.

  14. Three-phase bone scanning in reflex sympathetic dystrophy of the extremities: a semi-quantitative analysis

    International Nuclear Information System (INIS)

    Granier, P.; Manicourt, D.H.; Pauwels, S.; Nagant de Deuxchaisnes, C.; Beckers, C.

    1994-01-01

    Three-phase bone scanning of the extremities (foot or hand) was performed in 40 normal subjects and in 56 patients with an unequivocal clinical diagnosis of reflex sympathetic dystrophy. The scintigraphic parameters studied were the ratios of tracer (SUPD SUPG Tc) activity in the affected side over the healthy side established for blood flow, blood pool, early vasculo-tissular fixation, and late bone fixation. In the controls, blood flow, blood pool, and early fixation showed considerable interindividual variation and only the variation of late fixation remained within narrow limits. Statistical analysis revealed that late fixation was most closely correlated with early fixation, which in turn was most close correlated with blood pool. The clinical and pathophysiological significance of these data is discussed. (authors). 33 refs., 2 figs., 5 tabs

  15. Evaluation of the utility of temporal subtraction images in successive whole-body bone scans: a prospective clinical study

    International Nuclear Information System (INIS)

    Shiraishi, J.; Appelbaum, D.; Pu, Y.; Engelmann, R.; Li Qiang; Doi, K.

    2007-01-01

    We have begun a prospective clinical study for evaluating the clinical utility of temporal subtraction images in successive whole-body bone scans. The computerized temporal subtraction technique has been developed in order to highlight interval changes of abnormal lesions due to skeletal metastases, primary bone tumors, osteomyelitis, and fractures. In our initial preliminary results of the prospective study which was started on November 22, 2006 in our hospital, radiologists reported some interval changes which were not recognized in the initial standard readings, but were obvious when temporal subtraction images were viewed. The usefulness of the temporal subtraction images will be investigated in terms of its clinical utility by the prospective clinical study. (orig.)

  16. Bone radioisotope scanning: usefulness in the evaluation and observation of patients with breast cancer in clinical stage II, III, IV

    International Nuclear Information System (INIS)

    Cano P, R.A.

    1995-01-01

    The clinical records of 420 patients with diagnosis of breast cancer well documented by the pathological anatomy in clinical stage II, III and IV were reviewed. In each one of them has been done at least a bone scanning during the diagnosis. In 52 cases carried out sericeous dosages of CA 15-3 and in some cases it was necessary to administer Samarium-153 EDTMP as palliative therapy of bone pain. The presence of secondary gamma-graphic focuses was 0/84 cases (0%) in clinical stage II, 54/265 cases (20%) in III and 41/91 cases (45%) in IV. The one focus appeared in 6.7% of the cases. In 7 of the 52 cases that received sericeous dosages of CA 15-3 were detected secondary osseous lesions, and 5 of them presented a marker elevation. The bone scanning has shown in many cases the presence of getters focuses in singular places of skeleton, urinary excretory system or mammary tissue. The gamma rays from Sm-153 allowed us to get some appropriate basal views post-therapy of the secondary lesions. The results show that the great incidence of secondary lesions in the skeleton occurred in cases of stages III and IV unlike other countries. The serial repetition of the radioisotope scanning. The presence of one focus in the skeleton of a patient with a well-known neoplasia makes us to do a careful evaluation of the focus nature. The presence of tracer accumulation in the kidney, ureter and bladder allows us to infer the pathology of excretory system that is the first evidence of its presence in many cases. (author). 71 refs., 7 figs., 6 tabs

  17. Bone marrow trephine biopsy in Hodgkin's lymphoma. Comparison with PET-CT scan in 65 patients.

    Science.gov (United States)

    Lakhwani, Sunil; Cabello-García, Dolores; Allende-Riera, Ana; Cárdenas-Negro, Carlos; Raya, José María; Hernández-Garcia, Miguel T

    2018-02-09

    To compare bone marrow biopsy (BMB) and PET/CT in detecting bone marrow involvement in Hodgkin's lymphoma MATERIAL AND METHODS: Retrospective analysis of 65 patients with both tests in the initial staging or in relapse with special attention to the PET/CT uptake pattern. In 3 patients (4.6%), the BMB showed bone marrow involvement with the PET/CT being positive in them all: 2 with diffuse+multifocal pattern and one diffuse only. In 11 additional patients (total 14/65, 21%), bone marrow involvement was diagnosed by PET/CT because bone marrow uptake was above hepatic one. The pattern was focal only in 2 cases, multifocal in 5, diffuse in 3 and diffuse+multifocal in one. In these last 4 cases the BMB showed an unspecific myelopathy. PET/CT detects all cases with BMB affected and many that escape to biopsy, however when the uptake pattern is diffuse it could be by involvement or reactive hyperplasia and in those cases the BMB should be done. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  18. What expects rheumatologist from bone scan; Qu'attend le rhumatologue de la medecine nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, B. [Institut Calot, 62 - Berck sur Mer (France); Meys, E. [Centre Hospitalier Duchenne, 62 - Boulogne sur Mer (France)

    2003-11-01

    Conventional bone scintigraphy continues to be one of the most common diagnostic imaging requested by rheumatologist, despite development of new investigation modalities. Three (or two) phase bone scintigraphy, Single Photon Emission Computer Tomography have increased its value and provided new clinical roles. This review emphasizes through some practical clinical examples how to increase diagnostic value of the method, especially in the field of inflammatory diseases at early stages (rheumatoid arthritis and spondyl-arthropathy). Scintigraphy appears as a diagnostic tool, with requirements between clinical examination and radiographic examination-X Ray, computed tomography, ultrasonography, MRI. (author)

  19. 99mTc-HDP Bone Scan Findings of Acute Rhabdomyolysis of Lumbar Multifidus and Thigh Muscles and Bone Scan and US Signs of Acute Tubular Necrosis in Excessive Rabbit's Leaping: A Case Report

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Kim, Jang Min

    2008-01-01

    Marked rhabdomyolysis (RML) complicated by acute tubular necrosis is not a rare disease. It is characterized by disintegration of skeletal muscle fibers due to a variety of causes including excessive physical exercise, trauma, operation, infection, bed-ridden life, alcohol, drugs, toxins, exhaustion and others. We report a case of RML with acute renal failure studied using magnification bone scan which specifically identified the muscles injured by excessive rabbit's leap. The injured muscles recognized were the multifidus of the lumbar spine and the anterior and posterior muscle groups of the thigh. In addition, 99 mTc-HDP bone scan findings of acute tubular necrosis correlated with that of the sonographic signs are described. Patient was treated simply with normal saline hydration and bed rest and uneventfully recovered to be discharged on the fourth hospital day. Lab data on the final hospital day: LDH=20 IU/L (normalized) and CPK=600 IU/L (still higher than normal), BUN=14.2 mg/dl (normalized) and creatinin=1.5 mg/dl (normalized) GOT=20 mg/dl (normalized) and GPT=72 mg/dl (higher than normal), respectively

  20. {sup 99m}Tc-HDP Bone Scan Findings of Acute Rhabdomyolysis of Lumbar Multifidus and Thigh Muscles and Bone Scan and US Signs of Acute Tubular Necrosis in Excessive Rabbit's Leaping: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Kim, Jang Min [Sung Ae Hospital, Seoul (Korea, Republic of)

    2008-06-15

    Marked rhabdomyolysis (RML) complicated by acute tubular necrosis is not a rare disease. It is characterized by disintegration of skeletal muscle fibers due to a variety of causes including excessive physical exercise, trauma, operation, infection, bed-ridden life, alcohol, drugs, toxins, exhaustion and others. We report a case of RML with acute renal failure studied using magnification bone scan which specifically identified the muscles injured by excessive rabbit's leap. The injured muscles recognized were the multifidus of the lumbar spine and the anterior and posterior muscle groups of the thigh. In addition, {sup 99}mTc-HDP bone scan findings of acute tubular necrosis correlated with that of the sonographic signs are described. Patient was treated simply with normal saline hydration and bed rest and uneventfully recovered to be discharged on the fourth hospital day. Lab data on the final hospital day: LDH=20 IU/L (normalized) and CPK=600 IU/L (still higher than normal), BUN=14.2 mg/dl (normalized) and creatinin=1.5 mg/dl (normalized) GOT=20 mg/dl (normalized) and GPT=72 mg/dl (higher than normal), respectively.

  1. Evaluation of Efficacy of Bone Scan With SPECT/CT in the Management of Low Back Pain: A Study Supported by Differential Diagnostic Local Anesthetic Blocks.

    Science.gov (United States)

    Jain, Anuj; Jain, Suruchi; Agarwal, Anil; Gambhir, Sanjay; Shamshery, Chetna; Agarwal, Amita

    2015-12-01

    Conventional radiologic modalities provide details only about the anatomic aspect of the various structures of the spine. Frequently the structures that show abnormal morphology may not be the cause of low back pain (LBP). Functional imaging in the form of bone scan along with single photon emission computerized tomography (SPECT/CT) may be helpful in identifying structures causing pain, whether morphologically normal or not. The objective of this study is to evaluate the role of bone scan with SPECT/CT in management of patients with LBP. This is randomized double-blinded controlled study performed on 80 patients with LBP aged 20 to 80 years, ASA physical status I to III. Patients were randomized into bone scan and control groups consisting of 40 patients each. On the basis of the clinical features and radiologic findings a clinical diagnosis was made. After making a clinical diagnosis, the patients in bone scan group were subjected to bone scan with SPECT/CT. On the basis of the finding of the bone scan and SPECT/CT, a new working diagnosis was made and intervention was performed according to the new working diagnosis. Diagnostic blocks in the control group were given based on clinical diagnosis. Controlled comparative diagnostic blocks were performed with local anesthetic. The pain score just after the diagnostic block and at the time of discharge (approximately 4 h later) was recorded; the pain relief was recorded in percentage. In both the groups, sacroilitis was the most common diagnosis followed by facet joint arthropathy. The number of patients obtaining pain relief of >50% was significantly higher in the bone scan-positive group as compared with the control group. Three new clinical conditions were identified in the bone scan group. These conditions were multiple myeloma, avascular necrosis of the femoral head, and ankylosing spondylitis. Bone scan with SPECT/CT was found to complement the clinical workup of patients with LBP. Inclusion of bone scan with

  2. Radionuclide assessment of heterotopic ossification in spinal cord injury patients

    International Nuclear Information System (INIS)

    Prakash, V.

    1983-01-01

    Whole body /sup 99m/T-pyrophosphate bone scans were obtained and correlated with skeletal radiographs for detection of heterotopic ossification in 135 spinal injury patients. There were 40 patients with recent injury (less than 6 months) and 95 with injury of over 6 months duration. Heterotopic new bone was detected on the bone scan in 33.7% of 95 patients with spinal cord injuries of more than 6 months duration and 30% of 40 patients with injuries of less than 6 months. The radionuclide scan was found to be useful in detection of heterotopic ossification at its early stage and in its differentiation from other complications in spinal cord injury patients

  3. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  4. 99mTc-MDP combined blood pool and bone phase radionuclide imaging in papain-injected carpal joints

    International Nuclear Information System (INIS)

    Metcalf, M.R.; Twardock, A.R.; Sanecki, R.K.

    1985-01-01

    Scintigraphic changes, i.e., increased activity, were induced by 1% papain, dissolved in phosphate-buffered physiologic saline (pH 7.4), injected into one antebrachiocarpal joint in each of eight dogs. Scintigraphic evaluation was by the use of combined blood pool and bone phase scintigraphy of affected and normal carpi over a 28-day period. The qualitative and quantitative scintigraphic appearance in injected carpal joints were very similar in both blood pool and bone phases. The clinical use of combined blood pool and bone phase scintigraphy to diagnose early inflammatory joint changes appears limited

  5. Scintigraphic changes of osteoarthritis: An analysis of findings during routine bone scans to evaluate the incidence in an Indian population

    International Nuclear Information System (INIS)

    Samuel, Aban M; Jain, HM

    2012-01-01

    The reported prevalence of osteoarthritis (OA) varies according to the method that is used to detect it. X-rays are commonly used in the diagnosis of OA. However, marked osteoarthritic damage must be present to detect characteristic changes with radiologic imaging. Our intention was to evaluate bone scans (1) he occurrence of such changes, (2) he incidence of OA (single or multiple joints) in the general population (a mixture of urban and rural) who were asymptomatic. Data on OA incidence in India is sketchy and sparse as against more detailed information obtained from USA and European nations. Also, clinical rheumatologists are not well-versed with the potential application of bone scans in the management of arthritides. Two hundred and eighty nine planar images of routine bone scans were randomly evaluated by two trained nuclear medicine physicians. The ages of the patients ranged from 20 to over 80 years. It is observed that as the age increases, the incidence of joint involvement increases. However, it is worth noting that even in the age group of 20-40 years, as many as 34% of asymptomatic persons have involvement of the joints. In this age group, as the manifestation is probably in the inception stage, there is a tendency for single joint involvement as against multiple joints seen in the older age groups. Another point to note is that the incidence of joint involvement was not affected by weight. In our patient population, gross obesity was not seen. The predominant joints involved are the knees and hips, followed by the shoulders and ankles. Females show a higher incidence than males. Some patients would be having only a single site or multiple site involvement. This observation is important as in a single, simple test whole body survey gives more information with low radiation burden. Scintigraphic prevalence of OA is higher than reported in US, Europe, and Asia as this test is more sensitive in detecting early changes as compared to radiological changes

  6. Quantifying migration and polarization of murine mesenchymal stem cells on different bone substitutes by confocal laser scanning microscopy.

    Science.gov (United States)

    Roldán, J C; Chang, E; Kelantan, M; Jazayeri, L; Deisinger, U; Detsch, R; Reichert, T E; Gurtner, G C

    2010-12-01

    Cell migration is preceded by cell polarization. The aim of the present study was to evaluate the impact of the geometry of different bone substitutes on cell morphology and chemical responses in vitro. Cell polarization and migration were monitored temporally by using confocal laser scanning microscopy (CLSM) to follow green fluorescent protein (GFP)±mesenchymal stem cells (MSCs) on anorganic cancellous bovine bone (Bio-Oss(®)), β-tricalcium phosphate (β-TCP) (chronOS(®)) and highly porous calcium phosphate ceramics (Friedrich-Baur-Research-Institute for Biomaterials, Germany). Differentiation GFP±MSCs was observed using pro-angiogenic and pro-osteogenic biomarkers. At the third day of culture polarized vs. non-polarized cellular sub-populations were clearly established. Biomaterials that showed more than 40% of polarized cells at the 3rd day of culture, subsequently showed an enhanced cell migration compared to biomaterials, where non-polarized cells predominated (ppolarization predominated at the 7th day of culture (p=0.001). This model opens an interesting approach to understand osteoconductivity at a cellular level. MSCs are promising in bone tissue engineering considering the strong angiogenic effect before differentiation occurs. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Astronaut Bone Medical Standards Derived from Finite Element (FE) Models of QCT Scans from Population Studies

    Science.gov (United States)

    Sibonga, J. D.; Feiveson, A. H.

    2014-01-01

    This work was accomplished in support of the Finite Element [FE] Strength Task Group, NASA Johnson Space Center [JSC], Houston, TX. This group was charged with the task of developing rules for using finite-element [FE] bone-strength measures to construct operating bands for bone health that are relevant to astronauts following exposure to spaceflight. FE modeling is a computational tool used by engineers to estimate the failure loads of complex structures. Recently, some engineers have used this tool to characterize the failure loads of the hip in population studies that also monitored fracture outcomes. A Directed Research Task was authorized in July, 2012 to investigate FE data from these population studies to derive these proposed standards of bone health as a function of age and gender. The proposed standards make use of an FE-based index that integrates multiple contributors to bone strength, an expanded evaluation that is critical after an astronaut is exposed to spaceflight. The current index of bone health used by NASA is the measurement of areal BMD. There was a concern voiced by a research and clinical advisory panel that the sole use of areal BMD would be insufficient to fully evaluate the effects of spaceflight on the hip. Hence, NASA may not have a full understanding of fracture risk, both during and after a mission, and may be poorly estimating in-flight countermeasure efficacy. The FE Strength Task Group - composed of principal investigators of the aforementioned population studies and of FE modelers -donated some of its population QCT data to estimate of hip bone strength by FE modeling for this specific purpose. Consequently, Human Health Countermeasures [HHC] has compiled a dataset of FE hip strengths, generated by a single FE modeling approach, from human subjects (approx.1060) with ages covering the age range of the astronauts. The dataset has been analyzed to generate a set of FE strength cutoffs for the following scenarios: a) Qualify an

  8. Bone scanning in the evaluation of exercise-related stress injuries

    International Nuclear Information System (INIS)

    Wilcox, J.R. Jr.; Moniot, A.L.; Green, J.P.

    1977-01-01

    Bone scintigraphy was used to evaluate 34 patients with the physical findings and history of stress fracture of the lower extremity. Of the 34, 21 had abnormal studies, 11 involving the femoral neck, 9 the tibia, and 1 the femur. All of these had abnormal scintiscans prior to or at the time of the appearance of radiographic changes. Of the 9 with abnormal tibial studies, radiographic changes never evolved in 3. No false negatives were found among the 13 with normal scintiscans

  9. Novel use of gamma correction for precise {sup 99m}Tc-HDP pinhole bone scan diagnosis and classification of knee occult fractures

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong-Whee [Sung Ae General Hospital, Department of Nuclear Medicine, Seoul (Korea); Jeon, Ho-Seung [Sung Ae General Hospital, Department of Orthopedic Surgery, Seoul (Korea); Kim, Jang Min [Sung Ae General Hospital, Department of Radiology, Seoul (Korea); Park, Jung Mee; Kim, Sung-Hoon; Chung, Soo-Kyo [The Catholic University of Korea, Department of Radiology, College of Medicine, Seoul (Korea); Chung, Yong-An [The Catholic University of Korea, Department of Radiology, College of Medicine, Seoul (Korea); Incheon St. Mary' s Hospital, Institute of Catholic Integrative Medicine (ICIM), Incheon (Korea); Incheon St. Mary' s Hospital, The Catholic University of Korea, Department of Radiology, Incheon (Korea); Kim, E.E. [University of Texas MD Anderson Cancer Center, Department of Radiology and Nuclear Medicine, Houston, TX (United States)

    2010-08-15

    The aim of this study was to introduce gamma correction pinhole bone scan (GCPBS) to depict specific signs of knee occult fractures (OF) on {sup 99m}Tc-hydroxydiphosphonate (HDP) scan. Thirty-six cases of six different types of knee OF in 27 consecutive patients (male = 20, female = 7, and age = 18-86 years) were enrolled. The diagnosis was made on the basis of a history of acute or subacute knee trauma, local pain, tenderness, cutaneous injury, negative conventional radiography, and positive magnetic resonance imaging (MRI). Because of the impracticability of histological verification of individual OF, MRI was utilized as a gold standard of diagnosis and classification. All patients had {sup 99m}Tc-HDP bone scanning and supplementary GCPBS. GCPBS signs were correlated and compared with those of MRI. The efficacy of gamma correction of ordinary parallel collimator and pinhole collimator scans were collated. Gamma correction pinhole bone scan depicted the signs characteristic of six different types of OF. They were well defined stuffed globular tracer uptake in geographic I fractures (n = 9), block-like uptake in geographic II fractures (n = 7), simple or branching linear uptake in linear cancellous fractures (n = 4), compression in impacted fractures (n = 2), stippled-serpentine uptake in reticular fractures (n = 11), and irregular subcortical uptake in osteochondral fractures (n = 3). All fractures were equally well or more distinctly depicted on GCPBS than on MRI except geographic II fracture, the details of which were not appreciated on GCPBS. Parallel collimator scan also yielded to gamma correction, but the results were inferior to those of the pinhole scan. Gamma correction pinhole bone scan can depict the specific diagnostic signs in six different types of knee occult fractures. The specific diagnostic capability along with the lower cost and wider global availability of bone scanning would make GCPBS an effective alternative. (orig.)

  10. Novel use of gamma correction for precise 99mTc-HDP pinhole bone scan diagnosis and classification of knee occult fractures

    International Nuclear Information System (INIS)

    Bahk, Yong-Whee; Jeon, Ho-Seung; Kim, Jang Min; Park, Jung Mee; Kim, Sung-Hoon; Chung, Soo-Kyo; Chung, Yong-An; Kim, E.E.

    2010-01-01

    The aim of this study was to introduce gamma correction pinhole bone scan (GCPBS) to depict specific signs of knee occult fractures (OF) on 99m Tc-hydroxydiphosphonate (HDP) scan. Thirty-six cases of six different types of knee OF in 27 consecutive patients (male = 20, female = 7, and age = 18-86 years) were enrolled. The diagnosis was made on the basis of a history of acute or subacute knee trauma, local pain, tenderness, cutaneous injury, negative conventional radiography, and positive magnetic resonance imaging (MRI). Because of the impracticability of histological verification of individual OF, MRI was utilized as a gold standard of diagnosis and classification. All patients had 99m Tc-HDP bone scanning and supplementary GCPBS. GCPBS signs were correlated and compared with those of MRI. The efficacy of gamma correction of ordinary parallel collimator and pinhole collimator scans were collated. Gamma correction pinhole bone scan depicted the signs characteristic of six different types of OF. They were well defined stuffed globular tracer uptake in geographic I fractures (n = 9), block-like uptake in geographic II fractures (n = 7), simple or branching linear uptake in linear cancellous fractures (n = 4), compression in impacted fractures (n = 2), stippled-serpentine uptake in reticular fractures (n = 11), and irregular subcortical uptake in osteochondral fractures (n = 3). All fractures were equally well or more distinctly depicted on GCPBS than on MRI except geographic II fracture, the details of which were not appreciated on GCPBS. Parallel collimator scan also yielded to gamma correction, but the results were inferior to those of the pinhole scan. Gamma correction pinhole bone scan can depict the specific diagnostic signs in six different types of knee occult fractures. The specific diagnostic capability along with the lower cost and wider global availability of bone scanning would make GCPBS an effective alternative. (orig.)

  11. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site.

    Science.gov (United States)

    Doube, M; Firth, E C; Boyde, A; Bushby, A J

    2010-06-03

    Condylar fracture of the third metacarpal bone (Mc3) is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC) and subchondral bone (SCB) have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE) and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E) at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.

  12. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site

    Directory of Open Access Journals (Sweden)

    M Doube

    2010-06-01

    Full Text Available Condylar fracture of the third metacarpal bone (Mc3 is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC and subchondral bone (SCB have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.

  13. Radionuclide bone scintigraphy in early detection of avascular osteonecrosis occurred in recovered SARS patients after hormone therapy

    International Nuclear Information System (INIS)

    Wang Qian; Huang Lili; Qin Shuling; Wang Yu; Nie Yuxin; Liang Tiejun; Zhang Caiqun; Zhao Yamei

    2005-01-01

    Objective: To analyze the characteristics of bone scintigraphy in patients who recovered from the severe acute respiratory syndrome (SARS), and to evaluate the clinical value of bone scintigraphy in the early diagnosis of avascular osteonecrosis (AVN) after hormone therapy. Methods: Bone scintigraphy was performed in 66 SARS patients. Among them 54 underwent MRI in bilateral hips and knees. Both images were compared and followed up clinically. Results: Abnormal scintigraphy was found in 30 (45.5%) of the 66 recovered SARS patients. Total 82 foci were found in hip, knee, ankle, elbow, shoulder, wrist and the middle of the tibia. Hip and knee joints were the most involved sites. 25 patients with 71 lesions were symptomatic, whereas 11 in 5 patients were asymptomatic, lesions in 8 patients were multifocal. The lesions found in scintigraphy and MRI were concordant in 92.6% of the joints. But more lesions could be detected by bone scintigraphy. Conclusions: SARS patients have a high occurrence of AVN, usually involved in multiple sites. Bone scintigraphy should be the first choice method used for early detection of AVN. (authors)

  14. [Regional blood flow and bone uptake of methylene-diphosphonate-technetium-99m].

    Science.gov (United States)

    Vattimo, A; Martini, G; Pisani, M

    1983-05-30

    Sudeck's atrophy of the foot is an acute, patchy osteoporosis that, on bone scan, shows an increase in both bone blood flow and local bone uptake of bone-seeking radionuclides. The purpose of this study was to evaluate the relationship between bone uptake of 99mTc-MDP and local bone blood flow. In some patients with Sudeck's atrophy of one foot we measured local bone blood flow and bone uptake of 99mTc-MDP. External counting of radioactivity, with a count-rate of 1 second was performed for 60 minutes after i.v. injection of a known dose of 99mTc-MDP in some patients with Sudeck's atrophy of the foot. The regions of interest (ROI) were selected on the basis of a bone scan performed 24 hours earlier. We assumed that the data recorded during the first seconds (7-10) reflect local blood flow and the data at 60 minutes reflect the bone uptake. The ratio between the local blood flow in the involved and healthy foot was higher than the local bone uptake ratio. The ratio between bone uptake and local bone blood flow was higher in the normal foot than in the affected one. These results suggest that the bone avidity for bone-seeking radionuclides is lower in Sudeck's atrophy than in normal bone.

  15. Multidetector bone densitometer for supine lateral vertebral scanning of the lumbar spine

    International Nuclear Information System (INIS)

    Pommet, R.

    1990-01-01

    ORIS-ODX 240 bone densitometer is used to provide the density values of large group of women obtaining both frontal and lateral projection of the lumbar spine on each of them. This device is the prototype of Sophos L-XRA developed by CEA/DAMRI for SOPHA MEDICAL. It uses as photon source an X-ray tube with K-edge filtration (Neodyme oxide). The multidetector uses 24 NaI (Tl) scintillators, 24 PM tubes and 24 dual channel analyzers

  16. Differential diagnosis of trampoline fracture from osteomyelitis by bone scan with pinhole collimator.

    Science.gov (United States)

    Gauthé, Mathieu; Mestas, Danielle; Canavese, Federico; Samba, Antoine; Cachin, Florent

    2014-02-01

    A 2-year-old girl with recent history of trampoline fall presented to the A&E Department for complete functional impairment of the left lower extremity and fever. Blood examination revealed an inflammatory syndrome, while plain radiographs were normal. As magnetic resonance imaging was unavailable, a bone scintigraphy was performed. While standard acquisition found an intense uptake focused on the left proximal tibial metaphysis whose appearance was suggestive of acute hematogenous osteomyelitis, complementary acquisition with the pinhole collimator demonstrated that this abnormal uptake was clearly distinct from the cartilage growth plate. One month follow-up radiographs showed a fracture that confirmed the diagnosis of trampoline fracture.

  17. Abscess detection with radionuclides

    International Nuclear Information System (INIS)

    Alavi, J.B.

    1988-01-01

    Radionuclide studies may aid in the diagnosis and localization of intra-abdominal infections. Despite the introduction of new radiographic and ultrasound methods, there are several clinical situations in which radionuclide scans have proved useful. Those include detection of postoperative intra-abdominal abscess, evaluation of liver abscess, differentiation between pancreatic pseudocyst or abscess, evaluation of fever of unknown origin, and evaluation of inflammatory bowel disease. Each clinical situation is discussed separately here

  18. Comparison of sequential planar 177Lu-DOTA-TATE dosimetry scans with 68Ga-DOTA-TATE PET/CT images in patients with metastasized neuroendocrine tumours undergoing peptide receptor radionuclide therapy

    International Nuclear Information System (INIS)

    Sainz-Esteban, Aurora; Carril, Jose Manuel; Prasad, Vikas; Schuchardt, Christiane; Zachert, Carolin; Baum, Richard P.

    2012-01-01

    The aim of the study was to compare sequential 177 Lu-DOTA-TATE planar scans ( 177 Lu-DOTA-TATE) in patients with metastasized neuroendocrine tumours (NET) acquired during peptide receptor radionuclide therapy (PRRT) for dosimetry purposes with the pre-therapeutic 68 Ga-DOTA-TATE positron emission tomography (PET)/CT ( 68 Ga-DOTA-TATE) maximum intensity projection (MIP) images obtained in the same patients concerning the sensitivity of the different methods. A total of 44 patients (59 ± 11 years old) with biopsy-proven NET underwent 68 Ga-DOTA-TATE and 177 Lu-DOTA-TATE imaging within 7.9 ± 7.5 days between the two examinations. 177 Lu-DOTA-TATE planar images were acquired at 0.5, 2, 24, 48 and 72 h post-injection; lesions were given a score from 0 to 4 depending on the uptake of the radiopharmaceutical (0 being lowest and 4 highest). The number of tumour lesions which were identified on 177 Lu-DOTA-TATE scans (in relation to the acquisition time after injection of the therapeutic dose as well as with regard to the body region) was compared to those detected on 68 Ga-DOTA-TATE studies obtained before PRRT. A total of 318 lesions were detected; 280 (88%) lesions were concordant. Among the discordant lesions, 29 were 68 Ga-DOTA-TATE positive and 177 Lu-DOTA-TATE negative, whereas 9 were 68 Ga-DOTA-TATE negative and 177 Lu-DOTA-TATE positive. The sensitivity, positive predictive value and accuracy for 177 Lu-DOTA-TATE as compared to 68 Ga-DOTA-TATE were 91, 97 and 88%, respectively. Significantly more lesions were seen on the delayed (72 h) 177 Lu-DOTA-TATE images (91%) as compared to the immediate (30 min) images (68%). The highest concordance was observed for bone metastases (97%) and the lowest for head/neck lesions (75%). Concordant lesions (n = 77; mean size 3.8 cm) were significantly larger than discordant lesions (n = 38; mean size 1.6 cm) (p max ). However, concordant liver lesions with a score from 1 to 3 in the 72-h 177 Lu-DOTA-TATE scan had a lower SUV max

  19. Comparison of sequential planar {sup 177}Lu-DOTA-TATE dosimetry scans with {sup 68}Ga-DOTA-TATE PET/CT images in patients with metastasized neuroendocrine tumours undergoing peptide receptor radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sainz-Esteban, Aurora; Carril, Jose Manuel [Hospital Universitario Marques de Valdecilla, Department of Nuclear Medicine, Santander (Spain); Prasad, Vikas; Schuchardt, Christiane; Zachert, Carolin; Baum, Richard P. [Zentralklinik Bad Berka, Department of Nuclear Medicine and Centre for PET/CT, Bad Berka (Germany)

    2012-03-15

    The aim of the study was to compare sequential {sup 177}Lu-DOTA-TATE planar scans ({sup 177}Lu-DOTA-TATE) in patients with metastasized neuroendocrine tumours (NET) acquired during peptide receptor radionuclide therapy (PRRT) for dosimetry purposes with the pre-therapeutic {sup 68}Ga-DOTA-TATE positron emission tomography (PET)/CT ({sup 68}Ga-DOTA-TATE) maximum intensity projection (MIP) images obtained in the same patients concerning the sensitivity of the different methods. A total of 44 patients (59 {+-} 11 years old) with biopsy-proven NET underwent {sup 68}Ga-DOTA-TATE and {sup 177}Lu-DOTA-TATE imaging within 7.9 {+-} 7.5 days between the two examinations. {sup 177}Lu-DOTA-TATE planar images were acquired at 0.5, 2, 24, 48 and 72 h post-injection; lesions were given a score from 0 to 4 depending on the uptake of the radiopharmaceutical (0 being lowest and 4 highest). The number of tumour lesions which were identified on {sup 177}Lu-DOTA-TATE scans (in relation to the acquisition time after injection of the therapeutic dose as well as with regard to the body region) was compared to those detected on {sup 68}Ga-DOTA-TATE studies obtained before PRRT. A total of 318 lesions were detected; 280 (88%) lesions were concordant. Among the discordant lesions, 29 were {sup 68}Ga-DOTA-TATE positive and {sup 177}Lu-DOTA-TATE negative, whereas 9 were {sup 68}Ga-DOTA-TATE negative and {sup 177}Lu-DOTA-TATE positive. The sensitivity, positive predictive value and accuracy for {sup 177}Lu-DOTA-TATE as compared to {sup 68}Ga-DOTA-TATE were 91, 97 and 88%, respectively. Significantly more lesions were seen on the delayed (72 h) {sup 177}Lu-DOTA-TATE images (91%) as compared to the immediate (30 min) images (68%). The highest concordance was observed for bone metastases (97%) and the lowest for head/neck lesions (75%). Concordant lesions (n = 77; mean size 3.8 cm) were significantly larger than discordant lesions (n = 38; mean size 1.6 cm) (p < 0.05). No such significance was

  20. Frostbite and bone scanning: the use of 99mTc-labeled phosphates in demarcating the line of viability in frostbite victims

    International Nuclear Information System (INIS)

    Ikawa, G.; dos Santos, P.A.; Yamaguchi, K.T.; Stroh-Recor, C.; Ibello, R.

    1986-01-01

    Early diagnosis of the extent of bone and soft tissue damage is a very important step in treating a frostbite victim. The diagnostic use of Tc-99m-phosphates in assessing the viability of soft tissue and bone in frostbite was evaluated in the early post-thaw period. Four patients were treated with a combination of warm baths, rehydration, vasodilators, epidural block, fasciotomy, and debridement. Six scans were done to stage involvement. In three of the four cases, final involvement could be determined as early as the third day. When a specific level of soft tissue or bone uptake was determined, future scanning showed either improvement, or no change in three of the four patients. In our experience, Tc-99m-phosphate scans represent an improvement over other diagnostic tests for viability of tissues

  1. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype

    OpenAIRE

    Ali Al Kaissi; Farid Ben Chehida; Rudolf Ganger; Franz Grill

    2014-01-01

    We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT) scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (con...

  2. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype

    Directory of Open Access Journals (Sweden)

    Ali Al Kaissi

    2014-01-01

    Full Text Available We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (consanguineous marriage strongly suggests autosomal recessive pattern of inheritance. To our knowledge, this is the first report of neonatal death dwarfism of Grebe syndrome analyzed by CT scan-based phenotype.

  3. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype.

    Science.gov (United States)

    Al Kaissi, Ali; Chehida, Farid Ben; Ganger, Rudolf; Grill, Franz

    2014-01-01

    We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT) scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (consanguineous marriage) strongly suggests autosomal recessive pattern of inheritance. To our knowledge, this is the first report of neonatal death dwarfism of Grebe syndrome analyzed by CT scan-based phenotype.

  4. Role of radionuclide imaging in the diagnosis of chondrosarcoma

    International Nuclear Information System (INIS)

    McLean, R.G.; Choy, D.; Hoeschl, R.; Nayanar, V.; Murray, I.P.

    1985-01-01

    The diagnosis of chondrosarcoma may be difficult if there is an atypical radiographic appearance or an inconclusive biopsy. Radionuclide bone scans of 13 patients with chondrosarcoma were reviewed to assess if a pattern of scan features could be recognized in association with this tumor. A combination, including increased blood pool activity, moderate intensity of uptake, patchy uptake with cortical predominance of activity, minimal distortion of bony outline, and a well-defined scintigraphic margin, occurred regularly in the series. Recognition of this characteristic pattern of scintigraphic features in cases of suspected chondrosarcoma may assist in the diagnostic assessment

  5. Focal hot spot induced by a central subclavian line on bone scan.

    Science.gov (United States)

    Moslehi, Masood; Cheki, Mohsen; Dehghani, Tohid; Eftekhari, Mansoureh

    2014-01-01

    The diagnostic accuracy of nuclear medicine reporting can be improved by awareness of these instrument-related artifacts. Both awareness and experience are also important when it comes to detecting and identifying normal (and abnormal) variants. We present a case of hot spot on the upper right chest in the region of right subclavicular region resulting from injection of radiotracer from central subclavian line. A 52-year-old woman with a history of left breast cancer and recent bone pain was referred to our nuclear medicine department for skeletal survey. Anterior views of chest show a focus of increased radiotracer uptake corresponding to anterior arch of one of the right second rib. The nuclear physician reported it as a focal rib bony lesion and recommended radiological evaluation. As technician later explained, physicians realized that injection site was a central subclavian line on the right side and hot spot on that region is due to injection site. The appearance of both skeletal and soft-tissue uptake depends heavily on imaging technique (such as the route of radiotracer administration) and the interpreting physicians should be aware of the impact of technical factors on image quality.

  6. Multiple bony lesions other than femoral heads on {sup 99m}Tc-MDP bone scan in patients with avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Chun, Hae Kyung [St. Francisco Hospital, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%); the location of 79 lesions was other than the femoral head. This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated.

  7. Multiple bony lesions other than femoral heads on 99mTc-MDP bone scan in patients with avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung; Chun, Hae Kyung

    1997-01-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%;the location of 79 lesions was other than the femoral head, This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated

  8. Bone scintigraphy in prostate cancer: a French national survey

    International Nuclear Information System (INIS)

    Boneu, A.; Corone, C.; Giammarile, F.; Lumbroso, J.; Resche, I.

    1997-01-01

    A national survey has been performed in France concerning bone scan in prostatic carcinoma. Its aim was to define methods of performing examinations, criteria of analysis of imaging results and indications of radionuclide imaging in initial evaluation and post-therapeutic follow-up of the disease. Replies are given and recommendations are proposed in order to improve imaging quality, optimize interpretation and rationalize prescription of bone scintigraphy in case of prostatic carcinoma. (authors)

  9. Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs

    Czech Academy of Sciences Publication Activity Database

    Brzobohatá, Hana; Prokop, J.; Horák, M.; Jančárek, A.; Velemínská, J.

    2012-01-01

    Roč. 36, č. 3 (2012), s. 801-806 ISSN 0350-6134 Grant - others:GA UK(CZ) 613012 Keywords : frontal bone * three-dimensional imaging * laser scanning * surface registration Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 0.414, year: 2012

  10. Radionuclide trap

    International Nuclear Information System (INIS)

    McGuire, J.C.

    1978-01-01

    The deposition of radionuclides manganese-54, cobalt-58 and cobalt-60 from liquid sodium coolant is controlled by providing surfaces of nickel or high nickel alloys to extract the radionuclides from the liquid sodium, and by providing surfaces of tungsten, molybdenum or tantalum to prevent or retard radionuclide deposition

  11. Pattern of Prostate-Specific Antigen (PSA) Failure Dictates the Probability of a Positive Bone Scan in Patients With an Increasing PSA After Radical Prostatectomy

    Science.gov (United States)

    Dotan, Zohar A.; Bianco, Fernando J.; Rabbani, Farhang; Eastham, James A.; Fearn, Paul; Scher, Howard I.; Kelly, Kevin W.; Chen, Hui-Ni; Schöder, Heiko; Hricak, Hedvig; Scardino, Peter T.; Kattan, Michael W.

    2007-01-01

    Purpose Physicians often order periodic bone scans (BS) to check for metastases in patients with an increasing prostate-specific antigen (PSA; biochemical recurrence [BCR]) after radical prostatectomy (RP), but most scans are negative. We studied patient characteristics to build a predictive model for a positive scan. Patients and Methods From our prostate cancer database we identified all patients with detectable PSA after RP. We analyzed the following features at the time of each bone scan for association with a positive BS: preoperative PSA, time to BCR, pathologic findings of the RP, PSA before the BS (trigger PSA), PSA kinetics (PSA doubling time, PSA slope, and PSA velocity), and time from BCR to BS. The results were incorporated into a predictive model. Results There were 414 BS performed in 239 patients with BCR and no history of androgen deprivation therapy. Only 60 (14.5%) were positive for metastases. In univariate analysis, preoperative PSA (P = .04), seminal vesicle invasion (P = .02), PSA velocity (P < .001), and trigger PSA (P < .001) predicted a positive BS. In multivariate analysis, only PSA slope (odds ratio [OR], 2.71; P = .03), PSA velocity (OR, 0.93; P = .003), and trigger PSA (OR, 1.022; P < .001) predicted a positive BS. A nomogram for predicting the bone scan result was constructed with an overfit-corrected concordance index of 0.93. Conclusion Trigger PSA, PSA velocity, and slope were associated with a positive BS. A highly discriminating nomogram can be used to select patients according to their risk for a positive scan. Omitting scans in low-risk patients could reduce substantially the number of scans ordered. PMID:15774789

  12. Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

    Science.gov (United States)

    Mangano, Carlo; Piattelli, Adriano; Raspanti, Mario; Mangano, Francesco; Cassoni, Alessandra; Iezzi, Giovanna; Shibli, Jamil Awad

    2011-01-01

    Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.

  13. Efficacy of SPECT over planar bone scan in the diagnosis of solitary vertebral lesions in patients with low back pain

    International Nuclear Information System (INIS)

    Sudhakar, Pushpalatha; Bhushan, Shanti M.; Ranadhir, G.; Prabhakar Rao, V.V.S.; Sharma, Anshu Rajnish; Narsimuhulu, G.

    2010-01-01

    The purpose of our study has been to evaluate the efficacy of single photon emission computed tomography (SPECT) over planar bone scan in identifying solitary vertebral lesions in patients with low backache and its ability to differentiate various pathologies according to the uptake pattern. Materials and Methods: The study included twenty patients out of whom six patients presented with known carcinoma and fourteen patients with low back pain. SPECT was done in all following planar skeletal survey. Benign and malignant lesions were identified according to the uptake pattern in vertebral elements, based on Gary F. Gates observations. Final diagnosis was obtained by means of biopsy or correlation with radiograph or computed tomography (CT) or magnetic resonance imaging (MRI), and/or follow up. Results: SPECT detected additional 30% of solitary vertebral lesions that were obscured on planar scan. Seven out of twenty were localized in anterior vertebral body and were diagnosed as benign ostophytes in six and osteoma in one substantiating the previous observations. Out of six cases of known carcinoma, three were having solitary metastases and showed posterior vertebral body uptake with pedicle involvement. SPECT could localize specific lesions as source of pain in eleven patients with low back pain (78%) and identified various etiologies including benign tumors (osteoid osteoma and osteoma), facet arthritis, discitis, transverse process fractures and spondylolysis. Conclusion: Our study highlighted the higher diagnostic value of SPECT over planar skeletal scintigraphy in localizing solitary vertebral lesions in low backache patients. Based on SPECT pattern, malignant and benign lesions could be differentiated in the given clinical context. (author)

  14. Radionuclide examination in rheumatology

    International Nuclear Information System (INIS)

    Streda, A.; Kolar, J.; Valesova, M.

    1984-01-01

    On the basis of twenty years of experience with the use of radionuclides in bone and articular rheumatic diseases indications for such examinations are summed up. The main advantage of the use of radionuclide methods is that they bring forward early diagnosis of tissue reconstruction which can thus be detected at the stage of microstructural changes. They also provide earlier and more reliable detection of the degree of the pathological process than is provided by X-ray examination. In some cases scintiscan may also be found useful as a method for following up the results of treatment of rheumatic diseases. (author)

  15. Dosimetry of bone metastases in targeted radionuclide therapy with alpha-emitting {sup 223}Ra-dichloride

    Energy Technology Data Exchange (ETDEWEB)

    Pacilio, Massimiliano [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Medical Physics; Ventroni, Guido; Mango, Lucio [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Nuclear Medicin; De Vincentis, Giuseppe; Di Castro, Elisabetta; Frantellizzi, Viviana; Follacchio, Giulia Anna; Garkavaya, Tatiana [Rome Univ. (Italy). Dept. of Radiological, Oncological and Anatomo Pathological Sciences; Cassano, Bartolomeo; Lorenzon, Leda [Rome Univ. (Italy). Postgraduate School of Medical Physics; Pellegrini, Rosanna; Pani, Roberto [Rome Univ. (Italy). Dept. of Molecular Medicine; Ialongo, Pasquale [Azienda Ospealiera San Camillo Forlianini, Rome (Italy). Dept. of Radiology

    2016-01-15

    Ra-dichloride is an alpha-emitting radiopharmaceutical used in the treatment of bone metastases from castration-resistant prostate cancer. Image-based dosimetric studies remain challenging because the emitted photons are few. The aim of this study was to implement a methodology for in-vivo quantitative planar imaging, and to assess the absorbed dose to lesions using the MIRD approach. The study included nine Caucasian patients with 24 lesions (6 humeral head lesions, 4 iliac wing lesions, 2 scapular lesions, 5 trochanter lesions, 3 vertebral lesions, 3 glenoid lesions, 1 coxofemoral lesion). The treatment consisted of six injections (one every 4 weeks) of 50 kBq per kg body weight. Gamma-camera calibrations for {sup 223}Ra included measurements of sensitivity and transmission curves. Patients were statically imaged for 30 min, using an MEGP collimator, double-peak acquisition, and filtering to improve the image quality. Lesions were delineated on {sup 99m}Tc-MDP whole-body images, and the ROIs superimposed on the {sup 223}Ra images after image coregistration. The activity was quantified with background, attenuation, and scatter correction. Absorbed doses were assessed deriving the S values from the S factors for soft-tissue spheres of OLINDA/EXM, evaluating the lesion volumes by delineation on the CT images. In 12 lesions with a wash-in phase the biokinetics were assumed to be biexponential, and to be monoexponential in the remainder. The optimal timing for serial acquisitions was between 1 and 5 h, between 18 and 24 h, between 48 and 60 h, and between 7 and 15 days. The error in cumulated activity neglecting the wash-in phase was between 2 % and 12 %. The mean effective half-life (T{sub 1/2eff}) of {sup 223}Ra was 8.2 days (range 5.5-11.4 days). The absorbed dose (D) after the first injection was 0.7 Gy (range 0.2-1.9 Gy). Considering the relative biological effectiveness (RBE) of alpha particles (RBE = 5), D{sub RBE} = 899 mGy/MBq (range 340-2,450 mGy/MBq). The

  16. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    International Nuclear Information System (INIS)

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-01-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit

  17. Relation of prostatic specific antigen, bone scan and Gleason score in prostate cancer Nuclear Medicine Center IPEN - INEN, 1993-1995

    International Nuclear Information System (INIS)

    Mendoza Perez, German E.

    2006-01-01

    Objectives: To establish the relationship of serum prostate specific antigen (PSA), Gleason score and bone scan, to determine bone metastases in prostate cancer patients (PC). Material and Methods: A retrospective cases and series study was performed in patients with prostate cancer derived to the Centre of Nuclear Medicine IPEN-INEN from 1993 to 1995. 165 patients were included. Frequency charts were done for every study variable, quantitative variables were expressed by mean ± SD; for qualitative variables percentages were used. To confirm relations a Chi-square (χ2) test was applied. Sensitivity, specificity, positive predictive value and negative predictive value for a 20 ng/mL cut off point of PSA and a Gleason score of 8 were carried out using contingency charts. Diagnostic performance of this tests were performed applying R.O.C. curve. Results: Mean age was 71.27 ± 7.6 years. Bone metastases were found in 84 (50.9%) patients. For a 20 ng/mL PSA, sensitivity was of 0.92, specificity of 0.47, PPV of 0.64 and NPV of 0.84; for a Gleason score of 8, sensitivity was 0.59, specificity 0.69, PPV O.67 and NPV 0.62. The probability to have a positive bone scan with a Gleason score of 8 is up to 10% for ≤ 4 ng/mL PSA; 15% for ≤ 10 ng/mL PSA, and 20% if PSA level is ≤ 20 ng/mL. Conclusions: We conclude, for the studied population, that it is necessary to perform a bone scan in all recently diagnosed prostate cancer patients, independently of PSA levels and Gleason score, in order to determine if bone metastases are present. (author)

  18. Preparation and in vivo biological investigations on a novel radioligand for bone scanning: technetium-99m-labeled zoledronic acid derivative

    International Nuclear Information System (INIS)

    Lin Jianguo; Qiu Ling; Cheng Wen; Luo Shineng; Ye Wanzhong

    2011-01-01

    Introduction: To enable imaging at an earlier time after injection, a radiopharmaceutical with higher affinity for bone, larger ratio of bone-to-soft tissue uptake and more rapid clearance from blood is required. The nature of diphosphonic acid is a key factor to determine the advantages of the radiopharmaceuticals. The purpose of this study is to optimize the linker chain between the imidazolyl and geminal diphosphonate group in the zoledronic acid (ZL) to develop novel single photon emission computed tomography (SPECT) bone imaging agent. Methods: A novel ZL derivative, 1-hydroxy-3-(1H-imidazol-1-yl)propane-1,1-diyldiphosphonic acid (IPrDP), was successfully prepared and labeled with 99m Tc in a high labeling yield. Biodistribution of 99m Tc-IPrDP and 99m Tc-ZL in normal mice were studied and compared. SPECT bone scanning was performed on the rabbit and a series of dynamic and static images were recorded by Philips SKY Light emission computed tomography. Results: In the biodistribution studies, 99m Tc-IPrDP exhibits significant advantages on the bone resorption and the clearance from soft tissues compared with 99m Tc-ZL. Kinetics of blood clearance in mice showed that T 1/2α and T 1/2β of 99m Tc-IPrDP were 1.47 min and 46.47 min, while those of 99m Tc-ZL were 2.28 and 52.63 min respectively. Excellent images of the rabbit skeleton can be quickly obtained for 99m Tc-IPrDP, which was faster than 99m Tc-ZL and the clinically widely used bone imaging agent 99m Tc-MDP (technetium-99m labeled with methylenediphosphonate). Conclusions: 99m Tc-IPrDP possesses excellent characteristics for the potential application as a novel bone scanning agent.

  19. EORTC QLQ-BM22 and QLQ-C30 quality of life scores in patients with painful bone metastases of prostate cancer treated with strontium-89 radionuclide therapy

    International Nuclear Information System (INIS)

    Kurosaka, Shinji; Satoh, Takefumi; Chow, E.

    2012-01-01

    Approximately 80% of patients with prostate cancer will develop bone metastases, which often lead to bone pain and skeletal-related events. Sr-89 is an established alternative for the palliation of bone pain in prostate cancer. We aimed to assess the effect of Sr-89 radionuclide therapy on quality of life (QOL) in prostate cancer patients with painful bone metastases. Thirteen patients received a single intravenous injection of Sr-89 at a dose of 2.0 MBq/kg. All patients underwent QOL evaluation prior to Sr-89 treatment and 1, 2, and 3 months afterward using the Japanese version of the European Organisation for Research and Treatment of Cancer developed a Quality of Life questionnaire for Patients with Bone Metastases 22(EORTC QLQ-BM22), EORTC Quality of Life Group core questionnaire (EORTC QLQ-C30), a visual analog scale (VAS), and face scale. We also evaluated prostate-specific antigen (PSA) and serum alkaline phosphatase (ALP) response and toxicity of the Sr-89 therapy. The pain characteristics subscale of the EORTC QLQ-BM22 was significantly reduced from 1 month onward compared with the baseline. The functional interference and psychosocial aspects subscales were significantly higher than baseline from 2 months onward. At 2 months, VAS indicated a significant reduction in pain as compared to the baseline. Sr-89 therapy caused a nonsignificant reduction in PSA and ALP levels. No patients had leukocyte toxicity, and one patient had grade 3 platelet toxicity. Sr-89 radionuclide therapy can provide not only reduced pain characteristics but also better psychosocial aspects and functional interference in patients with painful bone metastases of prostate cancer. (author)

  20. Clinical role of skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J

    1975-12-01

    Malignant disease very often spreads to the skeleton. This is particularly true for carcinomas of the breast, the lungs, the prostate, and the thyroid. Knowledge of the state of the skeleton in these disorders is therefore desirable since patient management will largely depend on the early detection of bony deposits. Primary bone disease often spreads to soft tissue (lungs), and the early detection of this may alter significantly the therapeutic approach to the primary lesion. Traditionally, x-ray skeletal surveys and serum enzyme measurements provide indices which can be used in the staging of these disorders. Complementary techniques such as mammography, xeroradiography, thermography, and radionuclide imaging have been used to provide further relevant information. A number of benign bone diseases need early assessment in order to institute the best form of treatment. It is of importance to assess the circulation in localized areas of bone and to predict the appearance of avascular necrosis, to understand the healing mechanisms involved in fractures, and to predict the outcome of bone grafting. In this paper the clinical role of bone scanning is reviewed, particular attention being given to the recent advances brought about by the introduction of the /sup 99m/Tc compounds. It is important that the non-specialist should be aware of the great improvement in the results obtained and in the help they can give him in deciding on the best management of each patient as an individual.

  1. 99mTc-MDP bone scintigraphy findings representing osteoporosis

    International Nuclear Information System (INIS)

    Nam, Dae Gun; Moon, Tae Geon; Kim, Ji Hong; Son, Seok Man; Kim, In Ju; Kim, Yong Ki

    2001-01-01

    Bone scintigraphy with 99m Tc-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of 99m Tc-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia or osteoporosis

  2. Skeletal Scintigraphy (Bone Scan)

    Science.gov (United States)

    ... placed over the patient's body. SPECT involves the rotation of the gamma camera heads around the patient's ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  3. Radionuclides in thyroid cancer

    International Nuclear Information System (INIS)

    Mahadev, V.

    1980-01-01

    The three main areas of application of radionuclides in thyroid disease will be reviewed. Firstly thyroid radionuclide imaging in thyroid swellings, in relationship to lumps in the neck and ectopic thyroid tissue such as retrosternal goitre, and lingual goitre will be described. Future developments in the field including tomographic scanning, using the coded aperture method, and fluorescent scans and ultrasound are reviewed. The second area of application is the assessment and evaluation of thyroid function and the therapy of Grave's Disease and Plummer's Disease using radioiodine. The importance of careful collection of the line of treatment, results of treatment locally and the follow-up of patients after radioiodine therapy will be described. The third area of application is in the diagnosis and therapy of thyroid cancer. Investigation of thyroid swelling, and the diagnosis of functioning metastases are reported. The therapeutic iodine scan as the sole evidence of functioning metastatic involvement is recorded. Histological thyroid cancer appears to be increasingly encountered in clinical practice and the plan of management in relation to choice of cases for therapeutic scanning is discussed with case reports. Lastly the role of whole body scanning in relationship to biochemical markers is compared. In the changing field of nuclear medicine radionuclide applications in thyroid disease have remained pre-eminent and this is an attempt to reassess its role in the light of newer developments and local experience in the Institute of Radiotherapy, Oncology and Nuclear Medicine. (author)

  4. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39{+-}15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI{sup eventscan)}. Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI{sup eventscand}id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  5. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39±15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI eventscan) . Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI eventscand id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  6. 99mTc bone scanning agents preparation and chemical analysis of Tc(Sn)pyrophosphate, Tc(Sn)MDP and Tc(Sn)HMDP

    International Nuclear Information System (INIS)

    Kroesbergen, J.

    1986-01-01

    This thesis describes a comparison of the preparation, composition and properties of three bone scanning agents: 99m Tc(Sn)pyrophosphate, 99m Tc(Sn)MDP and 99m Tc(Sn)HMDP. This study has been performed for two reasons: First to investigate the preparation and composition of the radiopharmaceuticals as a function of experimental conditions. Together with previously reported results for 99m Tc(Sn)EHDP, obtained in a similar way, this enables to use well-defined preparations of the bone scanning agents. Secondly to gain an insight in the mechanism in which the agents behave 'in vivo'. Because the 'in vivo' process is too complicated to study directly, it seemed more appropriate to perform 'in vitro' investigations as simplifications of the 'in vivo' situation. 304 refs.; 26 figs.; 31 tabs

  7. Contribution of gammagraphy to the diagnosis of bone tumours. Study of 270 patients

    International Nuclear Information System (INIS)

    Caballero Carpena, O.; Esteban Velasco, J.

    1982-01-01

    In this study, two hundred seventy patients with bone tumours were evaluated by whole-body radionuclide studies: bone and vascular scan, using 99mTc MDP. In the group of primary bone tumour: 50 cases, the gammagraphy was positive in all cases except one myeloma. The morphology of the abnormal scan area of a primary bone tumour depend more of the site of the bone lesion than on its histopathology, and the size is significant by larger in sarcoma than others. The positivity of gammagraphy in the group of secondary bone tumours: 220 cases, was 93%, and the gammagraphic diagnosis being earlier than the radiologic one in 27%. Finally, we have studied the location of metastases, and the correlation between the positive scan and the request of exploration

  8. Bone scan can be spared in asymptomatic prostate cancer patients with PSA of ≤20 ng/ml and gleason score of ≤6 at the initial stage of diagnosis

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Fujimoto; Kiyohide; Shinkai, Takayuki

    2011-01-01

    According to several guidelines, it is acceptable to spare a bone scan in the patients who are newly diagnosed with low-risk prostate cancer. Our aim is to clarify a suitable group whereby a bone scan could be spared at the initial staging of prostate cancer. Consecutive 857 patients who were newly diagnosed from 2004 through 2009 and received bone scans using technetium 99m methylene diphosphonate at the initial staging were enrolled. The proportion of positive bone metastases by age distribution, prostate-specific antigen level at diagnosis, Gleason score and clinical T stage were evaluated. Univariate and multivariate logistic regression analyses were performed to identify the predictors of positive bone metastases. Of all 857 patients, 40 patients (4.7%) showed bone metastases. Patients with higher age, prostate-specific antigen level, clinical stage and Gleason score showed significantly higher rate of bone metastases (P 50 ng/ml and the Gleason score ≥4+3 were independent predictors of bone metastases. The incidences of bone metastases in patients with a prostate-specific antigen level of ≤20 ng/ml and Gleason score of ≤6 were reasonably low. Collectively, a bone scan is not necessary as a routine examination for these patients at their initial staging of prostate cancer. (author)

  9. {sup 99m}Tc-HDP Pinhole Bone Scan Features of Undetached Osteochondritis Dissecans of the Femoral Condyle: Report of a Case with Radiography, CT, and MRI Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee [Sung Ae Hospital, Seoul (Korea, Republic of); Choi, Woo Hee [Seoul St. Mary' s Hospital, Catholic University Medical School, Seoul (Korea, Republic of)

    2009-02-15

    OCD may be initiated by arrest of bone growth and subchondral osteosclerosis followed by either cartilage hypertrophy with calcification or enfolding with osteochondral bridging. Diagnosis can be made in most instances using magnetic resonance imaging (MRI) or computed tomography (CT) or invasive arthroscopy. As to usefulness of conventional radiography (CR) opinions diverge as some held it to be of limited value while others valuable. The controversy seems to be due to semantic confusion of OCD from osteonecrosis (ON) which are different entities. This report will describe a case of undetached OCD occurred in the medial femoral condyle in a middle-aged female. It was free of symptom and incidentally discovered on {sup 99m}Tc-HDP pinhole scan performed for patellar injury. Pinhole scan findings of OCD are correlated to those of CR, CT, and MRI. An electronic search of literature failed to reveal earlier publication of bone scan features of undetached OCD. Pathologically, OCD differs from ON in that the fragment in the former condition comes off from a normal vascular bony bed while that in the latter separates from an avascular bony bed. Indeed, bone fragment in ON is devascularized but that in OCD maintains vascularity until weighted images, respectively and the halo showed low signal intensity on both T1 and T2 images.

  10. Dental diseases and radionuclide imaging of the jaws.

    Science.gov (United States)

    Arias, Jose A; Pardo, Carlos; Olmos, Antonio; Cuadrado, Maria L; Ruibal, Alvaro

    2004-03-01

    The aim of this study was to compare the results of radionuclide bone scans of the jaws with data obtained at the nuclear medicine department from a brief and feasible dental history, taking special account of cases with a positive scan and no recent dental events. Ninety-eight patients undergoing radionuclide bone scan as part of their diagnosis in non-dental, oncological and non-oncological diseases were imaged with 99mTc-labelled oxidronate. Superior and inferior halves of the mandible and maxilla (392 quadrants) were regarded as normal or having an abnormally high uptake. A recent (1 year) dental history was also obtained through a brief questionnaire and data were referred to each quadrant of the jaws. The association between the bone scan and dental disease was assessed by means of the chi-squared test. The overall results of scintigraphy and history coincided in 66 patients (46 with abnormal and 20 with normal findings; P = 0.002). Twenty-five patients had a positive scintigram without any known dental disorder. Results of scintigraphy and history coincided in 254 quadrants (78 with abnormal and 176 with normal findings; P < 0.001). Eighty-three quadrants had hot spots in the scintigram without any known dental lesion. It can be concluded that abnormal jaw scintigrams are frequent in patients without known dental disease, and this may indicate silent osteoblastic activity. These observations should be reported to the dentist for several reasons. First, they may reveal asymptomatic dental lesions. Second, the use of oral prostheses and implants is increasing and they require the support of healthy alveolar bone.

  11. A comparative study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and 99mTc-MDP whole-body bone scanning for imaging osteolytic bone metastases

    International Nuclear Information System (INIS)

    Zhang, Lin; Chen, Lihua; Xie, Qiao; Zhang, Yongke; Cheng, Lin; Li, Haitao; Wang, Jian

    2015-01-01

    The objective of this study was to evaluate the feasibility and diagnostic value of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and 99m Tc-methylenediphosphonate (MDP) whole-body bone scanning (BS) for the detection of osteolytic bone metastases. Thirty-four patients with pathologically confirmed malignancies and suspected osteolytic bone metastases underwent 18 F-FDG PET/CT and 99m Tc-MDP whole-body BS within 30 days. The sensitivity, specificity, and accuracy with respect to the diagnosis of osteolytic bone metastases and bone lesions were compared between the two imaging methods. The sensitivity, specificity, and accuracy of 18 F-FDG PET/CT for the diagnosis of osteolytic bone metastases were 94.3% (95% confidence interval [CI], 91.6–96.2%), 83.3% (95% CI, 43.6–96.9%), and 94.2% (95% CI, 91.5–96.1%), respectively. It was found that 99m Tc-MDP whole-body BS could discriminate between patients with 50.2% (95% CI, 45.4–55.1%) sensitivity, 50.0% (95% CI, 18.8–81.2%) specificity, and 50.2% (95% CI, 45.5–55.1%) accuracy. 18 F-FDG PET/CT achieved higher sensitivity, specificity, and accuracy in detecting osteolytic bone metastases than 99mTc-MDP whole-body BS (p<0.001). F-FDG PET/CT has a higher diagnostic value than 99m Tc-MDP whole-body BS in the detection of osteolytic bone metastases, especially in the vertebra

  12. Radionuclide cisternography

    International Nuclear Information System (INIS)

    Song, H.H.

    1980-01-01

    The purpose of this thesis is to show that radionuclide cisternography makes an essential contribution to the investigation of cerebrospinal fluid (CSF) dynamics, especially for the investigation of hydrocephalus. The technical details of radionuclide cisternography are discussed, followed by a description of the normal and abnormal radionuclide cisternograms. The dynamics of CFS by means of radionuclide cisternography were examined in 188 patients in whom some kind of hydrocephalus was suspected. This study included findings of anomalies associated with hydrocephalus in a number of cases, such as nasal liquorrhea, hygromas, leptomeningeal or porencephalic cysts. The investigation substantiates the value of radionuclide cisternography in the diagnosis of disturbances of CSF flow. The retrograde flow of radiopharmaceutical into the ventricular system (ventricular reflux) is an abnormal phenomenon indicating the presence of communicating hydrocephalus. (Auth.)

  13. Bone scintigraphy on chronic hemodialyzed patients

    International Nuclear Information System (INIS)

    Koizumi, Yoshiko

    1990-01-01

    Patients with renal osteodystrophy (ROD) are classified into four types (secondary hyperparathyroidism: HPT, osteomalasia, ectopic calcification and normal bone scintigram type) according to findings of whole body bone scintigrams. Markedly high accumulations of Tc-99m-MDP are seen in the skull, especially in patients with HPT. For a quantitative evaluation of bone mineral dynamics, factor analysis (FA) was performed on bone scintigraphy in 36 patients with ROD and in 17 controls. Four were examined before and after parathyroidectomy (PTX). In the early phase (20 min) of bone scintigraphy, the bone factor was clearly extracted by FA. Two original parameters were calculated, one is bone radionuclide (RN) uptake count (BUC), the product of the total RN uptake count of the head and the contribution ratio, the other is bone RN uptake count ratio (BUR) derived by the time activity curve (physiological component of bone) of FA. Bone factor shown by FA is significantly different among patients with HPT, osteomalasia and controls. The value of BUC in patients with HPT is high compared to findings in the controls. The results of FA of ROD correlate well with planar images of bone scintigrams and with data on bone minerals, measured by quantitative methods such as single photon absorptiometry, CT attenuation number of the frontal bone, RN activity ratio ([frontal bone]/[brain]), using SPECT of bone scan. In the cases of PTX, the value of BUC was improved compared to preoperative data. FA of bone scintigraphy is a sensitive and useful method for quantitative evaluation of bone mineral dynamics and to assess the therapeutic effects in ROD. (author)

  14. Recurrent surgical site infection of the spine diagnosed by dual 18F-NaF-bone PET/CT with early-phase scan

    International Nuclear Information System (INIS)

    Shim, Jai-Joon; Lee, Jeong Won; Jeon, Min Hyok; Lee, Sang Mi

    2016-01-01

    We report a case of a 31-year-old man who showed recurrently elevated level of the serum inflammatory marker C-reactive protein (CRP) after spinal operation. He underwent 18 F-flurodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) and dual 18 F-sodium-fluoride ( 18 F-NaF) PET/CT with an additional early-phase scan to find a hidden inflammation focus. Only mildly increased 18 F-FDG was found at the surgical site of T11 spine on 18 F-FDG PET/CT. In contrast, dual 18 F-NaF bone PET/CT with early-phase scan demonstrated focal active inflammation at the surgical site of T11 spine. After a revision operation of the T11 spine, serum CRP level decreased to the normal range without any symptom or sign of inflammation. Inflammatory focus in the surgical site of the spine can be detected with using dual 18 F-NaF bone PET/CT scan with early-phase scan. (orig.)

  15. Evaluation of radiation dose to patients from Tc-99m during bone scan in nuclear medicine at Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Bambara, T. L.

    2014-07-01

    Internal dosimetry deals with the measurement of the radiation dose absorbed internally by an organ after the administration of isotopes for diagnosis and treatment. In the present study radiation absorbed dose has been calculated for technetium-99m methylene diphosphonate (Tc-99m MDP) which is used frequently for bone scan in Korle-Bu teaching hospital nuclear medicine department. In these cases a small amount of isotopes are accumulated in kidney, urinary bladder etc. Study on sixty-five patients undergoing bone scans has been performed quantitatively using e.soft software. The Tc-99m MDP doses were administered to the patients with activity ranging from 377.4 to 932.4 MBq depending on their weights, and were then scanned with an installed e.Cam SPECT system. A 256 × 1024 matrix size was used in acquiring the bone scans. Also the scans of five volunteer patients at three different times (1 hour, 2 hour and 3 hour after injection) were used to determine the residence time in the bladder and kidney. To determine the amount of activity in patient kidney and urinary bladder, conjugate view method was applied on images information. MIRD equation and OLINDA/EXM software were then used to estimate absorbed dose in different organs of patients. The absorbed value obtained from the two methods were compared. The activity in patient’s left kidney, right kidney and urinary bladder undergoing bone scan three hours after injection of Tc-99m were 1.52±0.48 MBq, 1.52±0.44 MBq 4.88±3.11MBq respectively. The residence time for the kidney and urinary bladder were 0.128±0.043 hour and 1.099±0.330 hour respectively. The absorbed dose per unit of injected activity (mGy/MBq) for bladder, kidneys, liver, lungs, red marrow, ovaries, pancreas, skin and spleen were calculated for the male and the female patients using the two methods. The absorbed dose values obtained from the two methods were compared. In the study for absorbed dose calculation, MIRD equation is in agreement with

  16. The implication of hot spots on bone scans within the irradiated field of breast cancer patients treated with mastectomy followed by radiotherapy

    International Nuclear Information System (INIS)

    Park, Won; Huh, Seung-Jae; Yang, Jung-Hyun

    2008-01-01

    The objective of this study was to analyze the implication of abnormal hot spots in the irradiated field of patients treated with mastectomy followed by radiotherapy for breast cancer. We reviewed 1842 consecutive bone scans performed on 292 patients treated with a modified radical mastectomy and followed by radiotherapy. If abnormal hot spots at the irradiated sites were detected in the bone scans, we evaluated further studies to determine whether bone metastases were present. Radiation was given using 4 or 6 MV X-rays at a dosage of 50.4 Gy during 5.5 weeks with a dosage per fraction of 1.8 Gy. The follow-up period was 25-136 months (median 57 months). Sixty patients (20.6%) developed bone metastasis. Solitary rib metastases were identified in four patients; all were detected outside of the irradiated field. Of 232 patients who did not develop bone metastases, hot spots in the irradiated field were detected in 30 patients (12.9%). A simple rib facture at the site of a hot spot was demonstrated in four patients. The cumulative incidence of hot spots at 5 years was 12.9%. The cumulative incidence of hot spots was more common in postmenopausal women, patients who were less than 60 kg, patients who received adjuvant hormonal therapy and patients who had radiation that included the supraclavicular area. We confirmed that the hot spots within the irradiated fields might be benign, especially in patients who were postmenopause, had a low body weight, received adjuvant hormonal therapy and who had radiation that included the supraclavicular area. (author)

  17. Normal bone and soft tissue distribution of fluorine-18-sodium fluoride and artifacts on 18F-NaF PET/CT bone scan: a pictorial review.

    Science.gov (United States)

    Sarikaya, Ismet; Elgazzar, Abdelhamid H; Sarikaya, Ali; Alfeeli, Mahmoud

    2017-10-01

    Fluorine-18-sodium fluoride (F-NaF) PET/CT is a relatively new and high-resolution bone imaging modality. Since the use of F-NaF PET/CT has been increasing, it is important to accurately assess the images and be aware of normal distribution and major artifacts. In this pictorial review article, we will describe the normal uptake patterns of F-NaF in the bone tissues, particularly in complex structures, as well as its physiologic soft tissue distribution and certain artifacts seen on F-NaF PET/CT images.

  18. Visualization of femoral vessels in delayed bone scans - a sign of arteriosclerosis. A comparison of /sup 99m/Tc-MDP and /sup 99m/Tc-DPD

    Energy Technology Data Exchange (ETDEWEB)

    Lantto, T.; Jaervi, K.; Toivio, I.; Vaehaetalo, S.; Vorne, M.

    1989-05-01

    The activity of femoral vessels in delayed bone scans was evaluated visually in 237 consecutive patients and quantified in 40 female patients. In visual analysis the patients were randomly divided into three groups and in quantitative analysis into four groups of equal size. Two different MDP preparations and one DPD preparation were used as bone-seeking agents. With aging, the activity in femoral vessels increased with all agents in visual analysis, significantly with MDPs (P < 0.001) between patients less than or equal to 60 years and > 60 years. In female patients with all agents a significant increase in femoral activity was found (P < 0.001 with MDPs, P < 0.05 with DPD). In patients > 60 years, the femoral uptake was significantly higher with MDP when compared with the DPD uptake (P < 0.01 with MDP 1, P < 0.05 with MDP 2). Between the MDPs no significant differences were found. In quantitative analysis the femoral vessel to soft tissue ratio was significantly higher in patients > 70 years when compared with patients less than or equal to 50 years with MDP. No difference was found with DPD. Histological examination of excised arteries of ten patients with intense femoral uptake of MDP showed arteriosclerosis and calcification in all cases. The findings suggest that the femoral visualization in delayed bone scans is probably related to arteriosclerosis and is not a non specific finding. There may be age-related differences in the distribution of MDP and DPD.

  19. Quantitation of size of myocardial infarctions by computerized transmission tomography. Comparison with hot-spot and cold-spot radionuclide scans

    International Nuclear Information System (INIS)

    Gerber, K.H.; Higgins, C.B.

    1983-01-01

    The current study evaluated the ability to quantitate the volume of myocardial infarctions when they are outlined by intravenously administered contrast media in the myocardial perfusion phase and in the phase of delayed contrast enhancement of the infarct. Quantitation by contrast media was assessed from computerized transmission tomography (CTT) scans of the ex situ heart and compared with quantitation by technetium-99m (/sup 99m/Tc)pyrophosphate (/sup 99m/Tc PYP) and thallium-201 (201Tl) scans of the same ex situ hearts. True volume was defined by histochemical morphometry. CTT during the contrast perfusion phase uniformly underestimated infarct size but had a good correlation with true volume. CTT during enhancement phase correlated closely with true volume (r . 0.98) and most precisely measured true size (y . 1.06 X 0.23). The /sup 99m/Tc PYP scan overestimated infarct volume (predictive overestimation of 6 to 199%) but had a good correlation with true volume. 201Tl underestimated infarct volume but correlated well with true volume. Thus, quantitation of infarct volume from CTT scans performed during either the perfusion or infarct enhancement phase after intravenous contrast media provides a good estimate of true infarct volume. Delineation of the infarct by contrast media in the ex situ heart is more precise during the phase of delayed enhancement of the infarct

  20. Radionuclide carrier

    International Nuclear Information System (INIS)

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  1. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site

    OpenAIRE

    M Doube; EC Firth; A Boyde; AJ Bushby

    2010-01-01

    Condylar fracture of the third metacarpal bone (Mc3) is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC) and subchondral bone (SCB) have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site tha...

  2. Application of sub-regional analysis to bone mineral density of the lower limb from whole body DXA scans

    International Nuclear Information System (INIS)

    Haddaway, Michael J; Davie, Michael W J; Davies, Helen L; Sharp, Christopher A

    2013-01-01

    Bone mineral density at spine and hip is widely used to diagnose osteoporosis. Certain conditions cause changes in bone density at other sites, particularly in the lower limb, with fractures occurring in non-classical locations. Bone density changes at these sites would be of interest for diagnosis and treatment. We describe an application, based on an existing software option for Hologic scanners, which allows reproducible measurement of bone density at six lower limb sites (upper femur, mid-femur, lower femur; upper leg, mid-leg, lower leg). In 30 unselected subjects, referred for bone density, precision (CV%) measured on 2 occasions, separated by repositioning, ranged from 1.7% (mid-femur) to 4.5% at the lowest leg site. Intra-operator precision, measured by three operators on ten subjects on three occasions, was between 1.0% and 2.9%, whilst inter-operator precision was between 1.0% and 3.6%, according to region. These values compare well with those at the spine and upper femur, and in the literature. There was no evidence that this operator agreement improved between occasions 1 and 3. This technique promises to be useful for assessing bone changes at vulnerable sites in the lower limb, in diverse pathological states and in assessing response to treatment. (paper)

  3. Combined bilateral idiopathic necrosis of the humerus and femur heads: Bone scan, X-ray, CT, and MRI findings. Kombinierte beidseitige idiopathische Nekrose der Humerus- und Femurkoepfe: Skelettszintigraphie, Roentgen-, CT- und MRT-Befunde

    Energy Technology Data Exchange (ETDEWEB)

    Piepenburg, R.; Hahn, K. (Mainz Univ. (Germany). Klinik fuer Nuklearmedizin); Doll, G. (Mainz Univ. (Germany). Klinik fuer Roentgendiagnostik); Grimm, J. (Mainz Univ. (Germany). Orthopaedische Klinik)

    1992-12-01

    Untreated aseptic bone necroses close to a joint commonly leads to severe secondary arthrosis and destruction of the joint within a short time. Therefore, only a diagnosis in an early stage of the disease offers the chance of a successful joint- preserving therapy. In cases of clinically suspected aseptic bone necrosis but still negative or doubtful X-ray findings, bone scans or MRI are reliable methods of verifying the diagnosis. (orig./MG).

  4. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J.

    1989-01-01

    Although few reports address the use of three-phase bone scanning (TPBS) and 111 In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses

  5. The imaging findings of metastatic neuroblastoma in the craniofacial bone in children

    International Nuclear Information System (INIS)

    Bian Xin; Wang Zhenchang; Xian Junfang; Li Mei; Yan Fei; Chen Qinghua; Yang Bentao; Chang Qinglin; Tian Qichang; Liu Zhonglin

    2009-01-01

    Objective: To investigate the characteristic imaging findings of metastatic neuroblastoma in the craniofacial bone in children. Methods: Imaging findings in 12 patients with metastatic neuroblastoma in the craniofacial bone were analyzed retrospectively. Among them, 10 patients undenvent plain CT scan, 6 underwent MRI and 7 underwent whole body single-photon emission computed tomography bone scanning. Results: In the 10 patients with CT images, lytic bone destruction and soft tissue masses were found in 9 eases, in which periosteal reaction was observed in 8 patients with spiculated periosteal reaction in 3 patients. The remaining 1 patient didn't show any abnormalities on CT images but had abnormal findings in bone scanning. Six patients with MR images showed abnormal signal intensity in the bone marrow of the craniofacial bone and adjacent soft tissue masses. Postcontrast T 1 -weighted imaging in 5 patients demonstrated remarkable enhancement of the bone marrow and soft tissue masses. Bone scanning of 7 patients showed abnormal foci of increased radionuclide activity of the craniofacial bone in 7 patients and metastasis at other body parts in 6 patients. Conclusion: The metastatic neuroblastoma in the craniofacial bone has its characteristic imaging findings which are helpful for correct diagnosis. (authors)

  6. Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

    Science.gov (United States)

    Sran, Meena M; Khan, Karim M; Keiver, Kathy; Chew, Jason B; McKay, Heather A; Oxland, Thomas R

    2005-12-01

    Biomechanical studies of the thoracic spine often scan cadaveric segments by dual energy X-ray absorptiometry (DXA) to obtain measures of bone mass. Only one study has reported the accuracy of lateral scans of thoracic vertebral bodies. The accuracy of DXA scans of thoracic spine segments and of anterior-posterior (AP) thoracic scans has not been investigated. We have examined the accuracy of AP and lateral thoracic DXA scans by comparison with ash weight, the gold-standard for measuring bone mineral content (BMC). We have also compared three methods of estimating volumetric bone mineral density (vBMD) with a novel standard-ash weight (g)/bone volume (cm3) as measured by computed tomography (CT). Twelve T5-T8 spine segments were scanned with DXA (AP and lateral) and CT. The T6 vertebrae were excised, the posterior elements removed and then the vertebral bodies were ashed in a muffle furnace. We proposed a new method of estimating vBMD and compared it with two previously published methods. BMC values from lateral DXA scans displayed the strongest correlation with ash weight (r=0.99) and were on average 12.8% higher (pBMC (AP or lateral) was more strongly correlated with ash weight than areal bone mineral density (aBMD; AP: r=0.54, or lateral: r=0.71) or estimated vBMD. Estimates of vBMD with either of the three methods were strongly and similarly correlated with volumetric BMD calculated by dividing ash weight by CT-derived volume. These data suggest that readily available DXA scanning is an appropriate surrogate measure for thoracic spine bone mineral and that the lateral scan might be the scan method of choice.

  7. Assessment of the risk factors for impending fractures following radiotherapy for long bone metastases using CT scan-based virtual simulation: a retrospective study

    International Nuclear Information System (INIS)

    Tatar, Zuzana; Soubrier, Martin; Dillies, Anne Françoise; Verrelle, Pierre; Boisgard, Stéphane; Lapeyre, Michel

    2014-01-01

    Radiotherapy for long bone metastases (RTLB) can be complicated by fractures, which considerably increase morbidity and mortality. The aim of this study was to analyze the risk factors for impending fractures following radiotherapy for long bone metastases (RTLB) using CT scan-based virtual simulation. Forty-seven (47) patients were treated with RTLB (18 lung, 11 breast, 10 prostate and 8 other cancers) for a period of 18 months. Two doctors analyzed the CT images prior to radiation therapy. The impending fractures were then monitored and the correlation between bone scan parameters and fracture occurrence was analyzed. The male gender ratio was 0.57 and the mean age 62.8 (33–93) years. The average size of the metastatic lesions was 32 (8–87) x 2 (6–81) x 52 (7–408) mm with cortical involvement (CI) in 66% of cases. The site was in the upper third of the bone in 92% of cases (28 femoral, 17 humeral and two tibial). Ten fractures occurred: two during RTLB, seven after one month and one after 6.6 months. The fractured lesions measured 48 (17–87) x 34 (12–66) x 76 (38–408) mm. The predictive parameters for fracture were osteolytic (39% vs. 10%; p = 0.02) and permeative lesions (42% vs. 0%; p < 0.0005), a Mirels score ≥9 (42% vs. 0%; p < 0.0005), circumferential CI ≥30% (71% vs. 0%, p < 0.00001), CI ≥45 mm in height (67% vs. 0%, p < 0.00001) and CI in thickness =100% (40% vs. 0%; p = 0.0008). In the multivariate analysis, circumferential CI ≥30% was the only predictive parameter for fracture (p = 0.00035; OR = 62; CI 95%: 6.5-595). Overall survival was 91% and 40% at one month and twelve months respectively. Prophylactic primary fixation surgery should always be considered when the circumferential CI ≥30%

  8. Detection of bone marrow involvement in patients with cancer

    International Nuclear Information System (INIS)

    Federico, M.; Silingardi, V.; Wright, R.M.

    1989-01-01

    Current methods for the study of bone marrow to evaluate possible primary or metastatic cancers are reviewed. Bone marrow biopsy, radionuclide scan, computed tomography and magnetic resonance imaging (MRI) are analyzed with regard to their clinical usefulness at the time of diagnosis and during the course of the disease. Bone marrow biopsy is still the examination of choice not only in hematologic malignancies but also for tumors that metastasize into the marrow. Radionuclide scans are indicated for screening for skeletal metastases, except for those from thyroid carcinoma and multiple myeloma. Computed tomography is useful for cortical bone evaluation. MRI shows a high sensitivity in finding occult sites of disease in the marrow but its use has been restricted by high cost and limited availability. However, the future of MRI in bone marrow evaluation seems assured. MRI is alredy the method of choice for diagnosis of multiple myeloma, when radiography is negative, and for quantitative evaluation of lymphoma when a crucial therapeutic decision (i.e. bone marrow transplantation) must be made. Finally, methods are being developed that will enhance the sensitivity and specificity of MRI studies of bone marrow

  9. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran

    OpenAIRE

    Salamat, Mohammad Reza; Salamat, Amir Hossein; Abedi, Iraj; Janghorbani, Mohsen

    2013-01-01

    Objective. Although several studies have investigated the association between body mass index (BMI) and bone mineral density (BMD), the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft) and lumbar vertebrae (L2-L4) using a Dual-Energy X-ra...

  10. Nuclear Medicine in Diagnosis and Therapy of Bone and Joint Diseases

    International Nuclear Information System (INIS)

    Riccabona, G.

    1999-01-01

    Concerning bone and joint diseases therapy of rheumatic synovitis (radiosynoviorthesis) was introduced in 1952 before clinically relevant diagnostic procedures were developed. Radionuclides of Sr and later on 99mTc phosphonates then started the wide use of bone scintigraphy since > 30 years. The diagnostic methods have an excellent sensitivity for detection of local abnormalities of bone metabolism, the specificity of such studies, however, is low. Modifications of the technique (3-phase-bone-scintigraphy, pinhole collimators, ROI-technique), increasing knowledge of pathological scan patterns and introduction of other radionuclide studies (67Ga, 201Tl, inflammation scans with 99mTc-leukocytes or 99mTc-HIG) as well as 18FDG-PET have increased the specificity significantly in recent years and improvements of imaging systems (SPECT) also increased the accuracy of diagnostic methods in diseases of bone and joints. Therapy of such diseases has made considerable progress: inflamed, swollen joints can effectively be treated with 90Y-, 186Re, 169Er-colloids or with 165Dy-particles by radiosynoviorthesis. Severe pain due to disseminated bone metastases of cancer or polyarthritis can be controlled by radionuclide therapy with 89Sr, 153Sm-EDTMP, 186Re- or 188Re-HEDP and possibly 117mSn-DTPA with an acceptable risk of myelodepression. Possibilities, technical details and limitations of radionuclide applications for diagnostic and therapeutic purposes must be considered if optimal benefit for individual patients should be achieved. Overall Nuclear Medicine can become an essential element in management of bone and joint diseases. The relationship of Nuclear Medicine to bone and joint pathology is peculiar: In 1952 treatment of rheumatic synovitis by radiosynoviorthesis with 198Au Colloid was started by Fellinger and Schmid before diagnostic approaches to bone pathology existed. Bone scintigraphy was introduced only in 1961 using 85Sr but obviously the unfavourable radiation

  11. The EANM practice guidelines for bone scintigraphy

    International Nuclear Information System (INIS)

    Wyngaert, T.V. den; Strobel, K.; Kampen, W.U.; Kuwert, T.; Bruggen, W. van der; Mohan, H.K.; Gnanasegaran, G.; Delgado-Bolton, R.; Weber, W.A.; Beheshti, M.; Langsteger, W.; Giammarile, F.; Mottaghy, F.M.; Paycha, F.

    2016-01-01

    The radionuclide bone scan is the cornerstone of skeletal nuclear medicine imaging. Bone scintigraphy is a highly sensitive diagnostic nuclear medicine imaging technique that uses a radiotracer to evaluate the distribution of active bone formation in the skeleton related to malignant and benign disease, as well as physiological processes. The European Association of Nuclear Medicine (EANM) has written and approved these guidelines to promote the use of nuclear medicine procedures of high quality. The present guidelines offer assistance to nuclear medicine practitioners in optimizing the diagnostic procedure and interpreting bone scintigraphy. These guidelines describe the protocols that are currently accepted and used routinely, but do not include all existing procedures. They should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary. (orig.)

  12. Radionuclide data

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Chapter 8 presents tables on selected alpha, beta, gamma and x-ray emitters by increasing energy; information on specific activity for selected radionuclides; naturally occurring radionuclides; the natural decay series; and the artificially produced neptunium series. A table of alpha emitters is listed by increasing atomic number and by energy. The table of β emitters presented is useful in identifying β emitters whose energies and possibly half-lives have been determined by standard laboratory techniques. It is also a handy guide to β-emitting isotopes for applications requiring specific half-lives and/or energies. Gamma rays for radionuclides of importance to radiological assessments and radiation protection are listed by increasing energy. The energies and branching ratios are important for radionuclide determinations with gamma spectrometry detectors. This section also presents a table of x-ray energies which are useful for radiochemical analyses. A number of nuclides emit x-rays as part of their decay scheme. These x-rays may be counted with Ar proportional counters, Ge planar or n-type Ge co-axial detectors, or thin crystal NaI(T1) scintillation counters. In both cases, spectral measurements can be made and both qualitative and quantitative information obtained on the sample. Nuclear decay data (energy and probability by radiation type) for more than one hundred radionuclides that are important to health physicists are presented in a schematic manner

  13. Comparison of capacity for diagnosis and visuality of auditory ossicles at different scanning angles in the computed tomography of temporal bone

    International Nuclear Information System (INIS)

    Ogura, Akio; Nakayama, Yoshiki

    1992-01-01

    Computed tomographic (CT) scanning has made significant contributions to the diagnosis and evaluation of temporal bone lesions by the thin-section, high-resolution techniques. However, these techniques involve greater radiation exposure to the lens of patients. A mean was thus sought for reducing the radiation exposure at different scanning angles such as +15 degrees and -10 degrees to the Reid's base line. Purposes of this study were to measure radiation exposure to the lens using the two tomographic planes and to compare the ability to visualize auditory ossicles and labyrinthine structures. Visual evaluation of tomographic images on auditory ossicles was made by blinded methods using four rankings by six radiologists. The statistical significance of the intergroup difference in the visualization of tomographic planes was assessed for a significance level of 0.01. Thermoluminescent dosimeter chips were placed on the cornea of tissue equivalent to the skull phantom to evaluate radiation exposure for two separate tomographic planes. As the result, tomographic plane at an angle of -10 degrees to Reid's base line allowed better visualization than the other plane for the malleus, incus, facial nerve canal, and tuba auditiva (p<0.01). Scannings at an angle of -10 degrees to Reid's base line reduced radiation exposure to approximately one-fiftieth (1/50) that with the scans at the other angle. (author)

  14. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1983-01-01

    The status of radionuclide generators for chemical research and applications related to the life sciences and biomedical research are reviewed. Emphasis is placed upon convenient, efficient and rapid separation of short-lived daughter radionuclides in a chemical form suitable for use without further chemical manipulation. The focus is on the production of the parent, the radiochemistry associated with processing the parent and daughter, the selection and the characteristic separation methods, and yields. Quality control considerations are briefly noted. The scope of this review includes selected references to applications of radionuclide generators in radiopharmaceutical chemistry, and the life sciences, particularly in diagnostic and therapeutic medicine. The 99 Mo-sup(99m)Tc generator was excluded. 202 references are cited. (orig.)

  15. Bone--bone marrow interactions

    International Nuclear Information System (INIS)

    Patt, H.M.

    1976-01-01

    Within medullary cavities, blood formation tends to be concentrated near bone surfaces and this raises interesting questions about hematopoietic consequences of radionuclide fixation in osseous tissue. Thus, it may be important, on the one hand, to consider the medullary radiation dose distribution as well as total marrow dose from bone-bound radioelements and, on the other, to inquire about possible hematopoietic implications of radiation damage to endosteal surfaces per se. The reasons for this are discussed

  16. Radionuclide imaging of musculoskeletal infection

    International Nuclear Information System (INIS)

    Palestr, Christopher J.; North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY; Love, Charito

    2007-01-01

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  17. Radionuclide imaging of musculoskeletal infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestr, Christopher J. [Albert Einstein College of Medicine, Bronx, NY (United States); North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging; E-mail: palestro@lij.edu; Love, Charito [North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging

    2007-09-15

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  18. Scanning Electron Microscope (SEM Evaluation of the Interface between a Nanostructured Calcium-Incorporated Dental Implant Surface and the Human Bone

    Directory of Open Access Journals (Sweden)

    Francesco Mangano

    2017-12-01

    Full Text Available Purpose. The aim of this scanning electron microscope (SEM study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods. A dental implant (Anyridge®, Megagen Implant Co., Gyeongbuk, South Korea with a nanostructured calcium-incorporated surface (Xpeed®, Megagen Implant Co., Gyeongbuk, South Korea, which had been placed a month earlier in a fully healed site of the posterior maxilla (#14 of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury. Despite the violent trauma that caused mobilization of the fixture, its surface appeared to be covered by a firmly attached, intact tissue; therefore, it was subjected to SEM examination. The implant surface of an unused nanostructured calcium-incorporated implant was also observed under SEM, as control. Results. The surface of the unused implant showed a highly-structured texture, carved by irregular, multi-scale hollows reminiscent of a fractal structure. It appeared perfectly clean and devoid of any contamination. The human specimen showed trabecular bone firmly anchored to the implant surface, bridging the screw threads and filling the spaces among them. Conclusions. Within the limits of this human histological report, the sample analyzed showed that the nanostructured calcium-incorporated surface was covered by new bone, one month after placement in the posterior maxilla, under an immediate functional loading protocol.

  19. Prospective Comparison of F-18 Choline PET/CT Scan Versus Axial MRI for Detecting Bone Metastasis in Biochemically Relapsed Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Wouter Huysse

    2017-10-01

    Full Text Available We compared fluor-18 choline positron emission tomography/computed tomography (PET/CT and axial skeleton magnetic resonance imaging (MRI prospectively obtained for the detection of bone metastases in non-castrated patients with biochemically recurrent prostate cancer following primary treatment. PET/CT was performed 45 min post-injection of 3–4 MBq/kg F-18 methyl choline. MRI included T1- and fluid sensitive T2-weighted images of the spine and pelvis. Readers were initially blinded from other results and all scans underwent independent double reading. The best valuable comparator (BVC defined the metastatic status. On the basis of the BVC, 15 out of 64 patients presented with 24 bone metastases. On a patient level, the sensitivity and specificity of MRI and PET were not significantly different. On a lesion level, the sensitivity of MRI was significantly better compared to PET, and the specificity did not differ significantly. In conclusion, axial MRI is an interesting screening tool for the detection of bone metastases because of its low probability of false negative results. However, F-18 choline PET is a valuable addition as it can overrule false positive MRI results and detect non-axial metastases.

  20. Bone mineral density test

    Science.gov (United States)

    BMD test; Bone density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis - BMD ... need to undress. This scan is the best test to predict your risk of fractures, especially of ...

  1. Subject-specific bone attenuation correction for brain PET/MR: can ZTE-MRI substitute CT scan accurately?

    Science.gov (United States)

    Khalifé, Maya; Fernandez, Brice; Jaubert, Olivier; Soussan, Michael; Brulon, Vincent; Buvat, Irène; Comtat, Claude

    2017-10-01

    In brain PET/MR applications, accurate attenuation maps are required for accurate PET image quantification. An implemented attenuation correction (AC) method for brain imaging is the single-atlas approach that estimates an AC map from an averaged CT template. As an alternative, we propose to use a zero echo time (ZTE) pulse sequence to segment bone, air and soft tissue. A linear relationship between histogram normalized ZTE intensity and measured CT density in Hounsfield units (HU ) in bone has been established thanks to a CT-MR database of 16 patients. Continuous AC maps were computed based on the segmented ZTE by setting a fixed linear attenuation coefficient (LAC) to air and soft tissue and by using the linear relationship to generate continuous μ values for the bone. Additionally, for the purpose of comparison, four other AC maps were generated: a ZTE derived AC map with a fixed LAC for the bone, an AC map based on the single-atlas approach as provided by the PET/MR manufacturer, a soft-tissue only AC map and, finally, the CT derived attenuation map used as the gold standard (CTAC). All these AC maps were used with different levels of smoothing for PET image reconstruction with and without time-of-flight (TOF). The subject-specific AC map generated by combining ZTE-based segmentation and linear scaling of the normalized ZTE signal into HU was found to be a good substitute for the measured CTAC map in brain PET/MR when used with a Gaussian smoothing kernel of 4~mm corresponding to the PET scanner intrinsic resolution. As expected TOF reduces AC error regardless of the AC method. The continuous ZTE-AC performed better than the other alternative MR derived AC methods, reducing the quantification error between the MRAC corrected PET image and the reference CTAC corrected PET image.

  2. Application of bone scintigraphy

    International Nuclear Information System (INIS)

    Rondain, J.E.S.

    1996-01-01

    Bone scanning has varied applications, particularly in the file of oncology. It is used in the diagnosis and follow-up of patients with cancers that metastatize to the bones (breast, prostate CA), also in primary bone cancers, infections of the bones and joints. In early stages of primary breast CA (stage I and II), the incidence of unsuspected bone metastasis is only 1-5%. On the other hand, bone scans serve as a baseline study if bone mets occur at some later stage. In patients with stage II and III breast CA, the conversion from normal to abnormal bone scans is 15% and 17%, respectively, clearly in favor of a baseline bone scan. For prostate CA, bone scanning should be used in conjunction with PSA level determination. In advanced disease, a bone scan will define the extent of the metastases, show problematic lesions in weight-bearing bones, and even allow us to evaluate response to therapy in follow-up bone scans. In patients with lung CA, a positive bone scan will make surgery of the primary lesion inappropriate. For other cancers, a bone scan maybe used if there are other signs, whether clinical or chemical, indicating bone involvement. In patients with GIT, liver, skin, brain or bladder CA, routine bone scanning may be considered superfluous. For patients with suspected infection, a 3-phase bone scan is more desirable. In patients with septic arthritis, the bones of each side of the joint take up the radiopharmaceutical while in patients with cellulitis without bony involvement, only the first two phases (dynamic and bloodpool images) will be abnormal. Bone scanning is also used in avascular lesions such as Legg-calve-Perthes disease where one will see reduced uptake of Tc99m MDP. The advent of SPECT imaging has greatly increased the sensitivity in diagnosing AVN. (author)

  3. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wollongong Univ.; Tomiyoshi, K.; Sekine, T.

    1997-01-01

    The present status and future directions of research and development on radionuclide generator technology are reported. The recent interest to develop double-neutron capture reactions for production of in vivo generators; neutron rich nuclides for radio-immunotherapeutic pharmaceuticals: and advances with ultra-short lived generators is highlighted. Emphasis is focused on: production of the parent radionuclide; the selection and the evaluation of support materials and eluents with respect to the resultant radiochemical yield of the daughter, and the breakthrough of the radionuclide parent: and, the uses of radionuclide generators in radiopharmaceutical chemistry, biomedical and industrial applications. The 62 Zn → 62 Cu, 66 Ni → 66 Cu, 103m Rh → 103 Rh, 188 W → 188 Re and the 225 Ac → 221 Fr → 213 Bi generators are predicted to be emphasized for future development. Coverage of the 99 Mo → 99m Tc generator was excluded, as it the subject of another review. The literature search ended June, 1996. (orig.)

  4. Evaluating the effect of a third-party implementation of resolution recovery on the quality of SPECT bone scan imaging using visual grading regression.

    Science.gov (United States)

    Hay, Peter D; Smith, Julie; O'Connor, Richard A

    2016-02-01

    The aim of this study was to evaluate the benefits to SPECT bone scan image quality when applying resolution recovery (RR) during image reconstruction using software provided by a third-party supplier. Bone SPECT data from 90 clinical studies were reconstructed retrospectively using software supplied independent of the gamma camera manufacturer. The current clinical datasets contain 120×10 s projections and are reconstructed using an iterative method with a Butterworth postfilter. Five further reconstructions were created with the following characteristics: 10 s projections with a Butterworth postfilter (to assess intraobserver variation); 10 s projections with a Gaussian postfilter with and without RR; and 5 s projections with a Gaussian postfilter with and without RR. Two expert observers were asked to rate image quality on a five-point scale relative to our current clinical reconstruction. Datasets were anonymized and presented in random order. The benefits of RR on image scores were evaluated using ordinal logistic regression (visual grading regression). The application of RR during reconstruction increased the probability of both observers of scoring image quality as better than the current clinical reconstruction even where the dataset contained half the normal counts. Type of reconstruction and observer were both statistically significant variables in the ordinal logistic regression model. Visual grading regression was found to be a useful method for validating the local introduction of technological developments in nuclear medicine imaging. RR, as implemented by the independent software supplier, improved bone SPECT image quality when applied during image reconstruction. In the majority of clinical cases, acquisition times for bone SPECT intended for the purposes of localization can safely be halved (from 10 s projections to 5 s) when RR is applied.

  5. Radionuclide arthrogram to evaluate knee prostheses loosening

    International Nuclear Information System (INIS)

    Ahn, U.

    2009-01-01

    Full text:This case is about a 78 year old lady who had 3TKRs on her left knee. The 2nd revision surgery was performed due to infection. After 6 weeks long procedure, that patient was discharged with satisfactory movement without sign of infection. 15 months after the surgery, the orthopaedic surgeon found that some pressure wave effects and pain with walking. There was no sign of infection clinically. Once X-ray could not confirm any micro-loosening, the surgeon wanted to investigate with radionuclide arthrogram for this difficult case. 40 MBq in 2mls of Calcium phytate colloid (from RADPHARM Australia) was injected into the knee joint space. 30 minutes static views revealed the tracer started to travel below the tibial component. 4 hours statics views clearly indicate the tibial component loosening also there was leakage of tracer through anterior tibial osteotomy screws into the level of ankle subcutaneously. Cobalt57 flood images provided the anatomical localisation. While the surgeon was planning new component for the 3rd revision surgery, the patient's pain disappeared with time. No more revision was considered with satisfactory level of movement. This was the first and only case of radio arthogram to our department, although we perform many bone scans with same reason. On published articles, overall sensitivity and specificity are variable from 85% to 100%. When we take look at other clinical experience, there are a number of reasons in the high accuracy and reliability of radionuclide arthrogram especially for knee prosthesis loosening. Therefore I want to emphasise the benefit of radionuclide arthrogram for both patient and surgeon as a reliable diagnosis with minimum discomfort.

  6. Comparison of preoperative computerized tomography scan imaging of temporal bone with the intra-operative findings in patients undergoing mastiodectomy

    International Nuclear Information System (INIS)

    Gerami, H.; Naghavi, E.; Wahabi-Moghadam, M.; Forghanparast, K.; Akbar, Manzar H.

    2009-01-01

    Objective was to compare the consistency rates of pre- and intra-operative radiological findings in patients with chronic suppurative otitis media (CSOM). In a cross-sectional study, 80 patients with CSOM underwent pre-operative CT scanning and we compared the results with intra-operative clinical findings during mastiodectomy from 2000-2004 in the Otology Department, Amiralmomenin Hospital of Guilan Medical University, Rasht, Iran. Sensitivity, specificity, positive and negative predictive value of CT scan in tympanic and mastoid cholesteatoma, ossicular chain erosion, tegmentympani erosion, dehiscence of facial canal, lateral semicircular canal (LSCC) fistula were assessed. Then, correlation between radiological findings and intra-operative findings were calculated. The mean age of patients was 27.9+-16.3 years. Mostly were males (n=57 [71.3%]). Correlation of preoperative radiological images with intra-operative clinical findings were moderate to good on tympanic cholesteatoma, mastoid cholesteatoma and ossicular chain erosion, but weak and insignificant in cases of tegmen erosion, facial canal dehiscene and LSCC fistulae. Preoperative CT scan may be helpful in decision-making for surgery in cases of cholesteatoma and ossicular erosion. Despite of limitations radiological scanning is a useful adjunct to management of CSOM. (author)

  7. Usefulness of bone scintigraphic classification and quantitative evaluation of bone mineralization with X-CT and SPECT in renal osteodystrophy

    International Nuclear Information System (INIS)

    Okamura, Terue; Fukuda, Teruo; Inoue, Yuuichi; Koizumi, Yoshiko; Ikeda, Hozumi; Ochi, Hironobu

    1987-01-01

    1. Bone scintigraphy with Tc-99m-MDP was performed on 52 patients with chronic renal failure. These bone scintigrams were classified into 4 groups, each of which was correlated to laboratory data and quantitative data of bone mineralization. Group I (32 patients) showed high accumulation of Tc-99m-MDP in the bone. High level of Alk-Pase and c-PTH, low BMC/BW, low EMI number and high radionuclide activity ratio (RN ratio) were observed. Group II (9 patients) demonstrated nuclear bone images with high background activity. RN ratio was slightly higher than the normal. Group III (11 patients) showed extraosseous accumulation of Tc-99m-MDP in the lung, kidney or soft tissues. One patient belonged to Group I. High level of Ca x P product and slightly high RN ratio were observed. In both Group II and III, BMC/BW and EMI number were normal. Group IV (one patient) showed normal skeletal activity on bone scintigram. The mean duration of hemodialysis was the longest in Group I. Our scintigraphic classification is convenient and might contribute an understanding of patho-physiological bone changes in such patients. 2. Subtotal parathyroidectomy (S-PTX) was employed in 18 of 52 patients on chronic renal failure with secondary hyperparathyroidism. These patients were studied before and after S-PTX using 6 different procedures; conventional radiography, microdensitometry, bone mineral analysis, measurement of EMI number with X-CT (frontal bone), bone scintigraphy, and RN ratio (frontal bone/brain) with SPECT. On the bone scan, the diffuse increased activity in the calvarium became less prominent after S-PTX in all 18 patients. We devised a new method to quantify the bone changes revealed by the bone scan; the RN ratio with SPECT. The ratio decreased markedly after surgery. This method seems to be most useful for detecting dynamic bone changes sensitively and quantitatively. (author)

  8. Intrathoracic stomach mimicking bone metastasis from thyroid cancer in whole-body iodine-131 scan diagnosed by SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Gomez, Francisco Javier; Riva-Perez, Pablo Antonio de la; Calvo-Moron, Cinta; Bujan-Lloret, Cristina; Cambil-Molina, Teresa; Castro-Montano, Juan [Dept. of Nuclear Medicine, Virgen Macarena University Hospital, Sevilla (Spain)

    2017-05-15

    The whole-body iodine-131 scintigraphy is an imaging technique in monitoring patients with a history of thyroid cancer. Although the rate of false positives is negligible, it is not nonexistent. We report the case of an intervened and treated patient for thyroid cancer with good clinical and biochemical response. Scintigraphic findings were consistent with unsuspected bone metastasis. Fused SPECT/CT data allowed accurate diagnosis of giant diaphragmatic hernia associated with intrathoracic stomach, a very rare pathology that can lead to false positive results. (author)

  9. In vitro stability of 99Tcsup(m) bone scan preparations from different manufacturers measured by various radiopharmaceutical parameters

    International Nuclear Information System (INIS)

    Pauwels, E.K.J.; Feitsma, R.I.J.

    1984-01-01

    The stability of 99 Tcsup(m)-labelled kit preparations of the bone seeking agents methylene diphosphonate (MDP), hydroxymethylene diphosphonate (HDP) and dicarboxypropane diphosphonate (DPD) was investigated. This was done by determining amounts of free 99 Tcsup(m) pertechnetate under various experimental conditions. The radiopharmaceuticals were made with 100 and 300 mCi 99 Tcsup(m) eluents and kept under the moderate condition of occasional inverting or continuous rolling. Analysis took place 5 min, 2 h, 4 h, and 6 h after preparation. In general free 99 Tcsup(m) pertechnetate concentrations were less when 100 mCi 99 Tcsup(m) eluent was used than with 300 mCi amounts. The level of impurity was also lower in occasionally inverted vials than in continuously rolled vials. Unexpected concentrations of free 99 Tcsup(m) pertechnetate (max. about 30%) were found in some commercial preparations. Only in one MDP and one HDP preparation did the average free 99 Tcsup(m) pertechnetate concentration stay within tolerable limits under all experimental conditions. The study demonstrates that careful quality control is needed and that only freshly prepared bone-seeking radiopharmaceuticals should be applied, especially when 99 Tcsup(m) eluents of about 300 mCi are used for kit preparation. (author)

  10. Indications of 99mTc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties

    International Nuclear Information System (INIS)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M.; Rosset, P.

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a 99 Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  11. Radionuclide examinations

    International Nuclear Information System (INIS)

    Lentle, B.C.

    1989-01-01

    This paper reports on radionuclide examinations of the pancreas. The pancreas, situated retroperitonally high in the epigastrium, was a particularly difficult organ to image noninvasively before ultrasonography and computed tomography (CT) became available. Indeed the organ still remains difficult to examine in some patients, a fact reflected in the variety of methods available to evaluate pancreatic morphology. It is something of a paradox that the pancreas is metabolically active and physiologically important but that its examination by radionuclide methods has virtually ceased to have any role in day-to-day clinical practice. To some extent this is caused by the tendency of the pancreas's commonest gross diseases emdash carcinoma and pancreatitis, for example emdash to result in nonfunction of the entire organ. Disorders of pancreatic endocrine function have generally not required imaging methods for diagnosis, although an understanding of diabetes mellitus and its nosology has been advanced by radioimmunoassay of plasma insulin concentrations

  12. Osseous and Nonosseous Bone Scan Findings in Liver Transplant Candidates with end-stage Chronic Liver Disease

    Directory of Open Access Journals (Sweden)

    Seval Erhamamcı

    2013-08-01

    Full Text Available Objective: End-stage chronic liver disease (CLD adversely affects the function of multiple organ systems including the skeletal system. The aim of this study was to assess osseous and nonosseous bone scintigraphy (BS findings in liver transplant (LT candidates with end-stage CLD. Methods: We retrospectively evaluated BS findings in 50 consecutive patients with end-stage CLD who were undergoing preoperative assessment for LT from January 2006 to December 2011. All the patients were analyzed with respect to clinical and laboratory parameters, and BS findings. Scintigrams were visually assessed for the presence of osseous and nonosseous abnormalities. Osseous abnormalities were classified as those indicating bone metabolism changes or metastatic bone disease. Typical scintigraphic findings denoting to changes in bone metabolism were the presence of decreased osseous uptake, increased periarticular uptake, asymmetrical or unusual uptake patterns. Nonosseous findings were classified according to the degree of soft-tissue uptake as mild and severe. Results: The group consisted of 46 adult and 4 adolescent patients. All adolescent patients had normal skeletal accumulation with growth plate uptake and one had mildly increased renal cortical activity. A total of 46 adult patients had one or more of the following osseous findings: generalized decrease in osseous uptake (n=4, 8.7%; bilateral decrease in lower extremity uptake (n=26, 56.5%; symmetrically increased periarticular uptake (n=26, 56.5%; bilateral cortical/periosteal increased uptake in the lower extremity indicating hepatic hypertrophic osteoarthropathy (HOA (n=8, 17.4%; bilateral increased sacroiliac activity (n=16, 34.8%; sacral activity (n=10, 21.7%, coccygeal activity (n=2, 4.3%, focally increased uptake suggestive of metastases (n=5, 10.9%. Three rib metastases appeared to be linear. Nonosseous findings observed in adult patients were mild diffuse liver uptake (n=4, 8.7% and bilateral

  13. Bone scintigraphy in chondroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Humphry, A.; Gilday, D.L.; Brown, R.G.

    1980-11-01

    Scintigraphy in 3 patients with chondroblastoma showed that the tumors were hyperemic and avidly accumulated the radionuclide. These changes were also present in adjacent normal bone, but to a lesser degree. This suggests that radionuclide uptake in chondroblastoma is a function of the blood supply to the tumor rather than primary matrix extraction.

  14. Evaluation of a short dynamic 18F-fluoride PET/CT scanning method to assess bone metabolic activity in spinal orthopedics.

    Science.gov (United States)

    Peters, Marloes J M; Wierts, Roel; Jutten, Elisabeth M C; Halders, Servé G E A; Willems, Paul C P H; Brans, Boudewijn

    2015-11-01

    A complication after spinal fusion surgery is pseudarthrosis, but its radiological diagnosis is of limited value. (18)F-fluoride PET with its ability to assess bone metabolism activity could be of value. The goal of this study was to assess the clinical feasibility of calculating the static standardized uptake value (SUV) from a short dynamic scan without the use of blood sampling, thereby obtaining all dynamic and static parameters in a scan of only 30 min. This approach was tested on a retrospective patient population with persisting pain after spinal fusion surgery. In 16 patients, SUVs (SUV max, SUV mean) and kinetic parameters (K 1, k 2, k 3, v b, K i,NLR, K 1/k 2, k 3/(k 2 + k 3), K i,patlak) were derived from static and dynamic PET/CT scans of operated and control regions of the spine, after intravenous administration of 156-214 MBq (18)F-fluoride. Parameter differences between control and operated regions, as well as between pseudarthrosis and fused segments were evaluated. SUVmean at 30 and 60 min was calculated from kinetic parameters obtained from the dynamic data set (SUV mean,2TCM). Agreement between measured and calculated SUVs was evaluated through Bland-Altman plots. Overall, statistically significant differences between control and operated regions were observed for SUV max, SUV mean, K i,NLR, K i,patlak, K 1/k 2 and k 3/(k 2 + k 3). Diagnostic CT showed pseudarthrosis in 6/16 patients, while in 10/16 patients, segments were fused. Of all parameters, only those regarding the incorporation of bone [K i,NLR, K i,patlak, k 3/(k 2 + k 3)] differed statistically significant in the intervertebral disc space between the pseudarthrosis and fused patients group. The mean values of the patient-specific blood clearance rate [Formula: see text] differed statistically significant between the pseudarthrosis and the fusion group, with a p value of 0.011. This may correspond with the lack of statistical significance of the SUV values between pseudarthrosis and

  15. Detection of subdural empyema with radionuclides

    International Nuclear Information System (INIS)

    McKillop, J.H.; Holtzman, D.S.; McDougall, I.R.

    1980-01-01

    Computed tomography (CT) is now the standard method of confirming a diagnosis of suspected subdural empyema. We report a case in which the radionuclide brain scan was abnormal at a time when the CT scan was normal. An 111 In-labeled leukocyte scan was also performed in this patient and demonstrated abnormal uptake in the empyema. The scintigraphic findings in a second case of subdural empyema are also described. The relative roles of radionuclide studies and CT scans in the patient with suspected subdural empyema are discussed

  16. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    International Nuclear Information System (INIS)

    Caiazza, S.; Falcinelli, G.; Pintucci, S.

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized

  17. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    Energy Technology Data Exchange (ETDEWEB)

    Caiazza, S.; Falcinelli, G.; Pintucci, S. (Istituto Superiore di Sanita, Rome (Italy))

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized.

  18. A Novel Automated Platform for Quantifying the Extent of Skeletal Tumour Involvement in Prostate Cancer Patients Using the Bone Scan Index

    DEFF Research Database (Denmark)

    Ulmert, David; Kaboteh, Reza; Fox, Josef J.

    2012-01-01

    a fully automated method of quantifying the BSI and determining the clinical value of automated BSI measurements beyond conventional clinical and pathologic features. Design, setting, and participantsWe conditioned a computer-assisted diagnosis system identifying metastatic lesions on a bone scan......, and outcome) scored the BSI measurements twice. We measured prediction of outcome using pretreatment Gleason score, clinical stage, and prostate-specific antigen with models that also incorporated either manual or automated BSI measurements. MeasurementsThe agreement between methods was evaluated using...... Pearson's correlation coefficient. Discrimination between prognostic models was assessed using the concordance index (C-index). Results and limitations Manual and automated BSI measurements were strongly correlated (ρ=0.80), correlated more closely (ρ=0.93) when excluding cases with BSI scores ≥10 (1...

  19. Photopenia of the femoral head on 3 phase bone scan using Tc-99m MDP with acute irritable hip in the preschool children: comparison with MR findings

    International Nuclear Information System (INIS)

    Ryu, Young Hoon; Lee, Jong Doo; Yoon, Choon Sik; Suh, Jin Suck; Jeon, Tae Joo

    1998-01-01

    The child with acute irritable hip is always a diagnostic challenge. Photopenia of femur head is described in Legg-Calve-Perthes disease (LCP). However, it can be seen in cases of septic arthritis (SA) with interruption of vascular supply. Despites being uncommon, recognition of SA as a cause of photopenia is important and requires urgent referral to decompression and drainage. This study was to evaluate causes and scintigraphic features of photopenia of femur head in patients with acute irritable hip and to correlate them with MR findings. 15 patients with acute irritable hip showed photopenia of femur head on bone scan were included. Mean age was 5.3 yrs ( 9 months to 8 yrs). There were 9 patients with LCP and 3 with septic arthritis combined with osteomyelitis. All parents underwent 3 phase bone scan and hip MRI within 2 days interval. Patterns of photopenia of femur head was divided into partial, complete and extending to the metaphysis. All patients with LCP showed partial photopenia confined to femur epiphysis. Whereas, 1 with septic arthritis demonstrated complete photopenia of femur head and in 2 with septic arthritis and 3 with septic arthritis combined with osteomyelitis revealed complete photopenia of femur head extending to the metaphyseal area. In cases with septic arthritis, increased uptake affecting both sides of hip joint except for photopenic area is also noted. On MRI, all patients with LCP showed abnormalities confined to the epiphysis. In cases with septic arthritis, abnormalities are not confined to the epiphysis and marrow edema and joint effusion were also noted. In evaluating photopenia of the femur head, it would be helpful to distinguish between the photopenia localized to the femoral epiphysis as seen in cases of LCP and complete photopenia of femur head with extension to the metaphysis as seen in cases of septic arthritis. Recognition of complete with extension to the metaphysis help guide urgent proper management of septic arthritis

  20. Photopenia of the femoral head on 3 phase bone scan using Tc-99m MDP with acute irritable hip in the preschool children: comparison with MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Young Hoon; Lee, Jong Doo; Yoon, Choon Sik; Suh, Jin Suck; Jeon, Tae Joo [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1998-07-01

    The child with acute irritable hip is always a diagnostic challenge. Photopenia of femur head is described in Legg-Calve-Perthes disease (LCP). However, it can be seen in cases of septic arthritis (SA) with interruption of vascular supply. Despites being uncommon, recognition of SA as a cause of photopenia is important and requires urgent referral to decompression and drainage. This study was to evaluate causes and scintigraphic features of photopenia of femur head in patients with acute irritable hip and to correlate them with MR findings. 15 patients with acute irritable hip showed photopenia of femur head on bone scan were included. Mean age was 5.3 yrs ( 9 months to 8 yrs). There were 9 patients with LCP and 3 with septic arthritis combined with osteomyelitis. All parents underwent 3 phase bone scan and hip MRI within 2 days interval. Patterns of photopenia of femur head was divided into partial, complete and extending to the metaphysis. All patients with LCP showed partial photopenia confined to femur epiphysis. Whereas, 1 with septic arthritis demonstrated complete photopenia of femur head and in 2 with septic arthritis and 3 with septic arthritis combined with osteomyelitis revealed complete photopenia of femur head extending to the metaphyseal area. In cases with septic arthritis, increased uptake affecting both sides of hip joint except for photopenic area is also noted. On MRI, all patients with LCP showed abnormalities confined to the epiphysis. In cases with septic arthritis, abnormalities are not confined to the epiphysis and marrow edema and joint effusion were also noted. In evaluating photopenia of the femur head, it would be helpful to distinguish between the photopenia localized to the femoral epiphysis as seen in cases of LCP and complete photopenia of femur head with extension to the metaphysis as seen in cases of septic arthritis. Recognition of complete with extension to the metaphysis help guide urgent proper management of septic arthritis.

  1. Phosphate-induced metal stabilization: Use of apatite and bone char for the removal of soluble radionuclides in authentic and simulated DOE groundwater

    International Nuclear Information System (INIS)

    Bostick, W.D.; Jarabek, R.J.; Conca, J.L.

    1999-01-01

    The apatite group of minerals is a family of calcium phosphate phases. Apatite is the principal component of bone tissue, and it also occurs naturally as mineral deposits in the geosphere. Bone char is calcined (coked) animal bone, containing activated carbon as well as calcium phosphate mineral phases. Apatite IItrademark is a more reactive form of apatite, supplied by UFA Ventures, Inc., at a cost of approximately 1/4 that of commercial bone char. Apatite is shown to be effective for the removal of select heavy metal impurities in groundwater. Previous investigations have demonstrated that apatite is an effective medium for the stabilization of soluble lead, cadmium, and zinc from mine waste leachate by the formation of highly insoluble precipitate phases. The performance of bone char and apatite II are compared with other candidate sorption media (including granular activated carbon and anion exchange resin) for the removal of soluble uranyl ion in synthetic DOE Site groundwater supplemented with varying levels of interfering nitrate ion. Apatite II has a greater affinity for U(VI), especially in the presence of nitrate ion, as evidenced by a larger value for the conditional distribution coefficient (Kd) in batch test experiments. Contact of uranyl nitrate solution with apatite II is shown to produce highly insoluble mineral phases of the autunite group (calcium uranyl phosphate hydrates). Apatite II is also demonstrated to be moderately effective for the removal of soluble radioactive isotopes of strontium, but not cesium, when these ions are supplemented into authentic DOE Site groundwater

  2. Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation μCT

    International Nuclear Information System (INIS)

    Raum, K; Leguerney, I; Chandelier, F; Talmant, M; Saied, A; Peyrin, F; Laugier, P

    2006-01-01

    200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation μCT (SR-μCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm -3 and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 ± 1.1 Mrayl versus 9.3 ± 1.0 Mrayl, DMB: 1.06 ± 0.07 g cm -3 versus 1.16 ± 0.05 g cm -3 , paired t-test, p 2 = 0.174, p -4 ) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R 2 = 0.39, p -4 ). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-μCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-μCT

  3. Evaluation of bone scan by scintigraphy to detect subclinical invasion of the mandible by squamous cell carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Baker, H.L.; Woodbury, D.H.; Krause, C.J.; Saxon, K.G.; Stewart, R.C.

    1982-01-01

    A prospective study using scintigraphy was performed to compare the sensitivity of the Panorex roentgenogram and the bone scan in detecting subclinical invasion of the mandible by squamous cell carcinoma of the oral cavity and floor of the mouth. Twenty-five patients with squamous cell carcinoma of the floor of the mouth were evaluated preoperatively by both the Panorex and scintigraphic techniques and the results compared with postoperative pathologic findings. In 13 (52%) of the cases, Panorex and scintigraphic techniques were comparable in detecting tumor involvement in bone. In eight cases (32%) all three modalities had normal pathologic indications of the mandible. However, in four cases (16%) results of the scintigraphic techniques were abnormal and the Panorex, normal. In four separate cases, the extent of lesion demonstrable by scintiscanning was greater than delineated by Panorex; surgical specimen confirmed this finding. Pathologic examination of operative specimens confirmed tumor involvement. These data lead us to believe that the scintigraphic techniques may be more sensitive in detecting early mandibular involvement with squamous cell carcinoma than the Panorex technique and may help alter the therapeutic approach

  4. Scanning Electron Microscopy-Energy-Dispersive X-Ray (SEM/EDX): A Rapid Diagnostic Tool to Aid the Identification of Burnt Bone and Contested Cremains.

    Science.gov (United States)

    Ellingham, Sarah T D; Thompson, Tim J U; Islam, Meez

    2018-03-01

    This study investigates the use of Scanning electron microscopy-energy-dispersive X-ray (SEM-EDX) as a diagnostic tool for the determination of the osseous origin of samples subjected to different temperatures. Sheep (Ovis aries) ribs of two experimental groups (fleshed and defleshed) were burned at temperatures of between 100°C and 1100°C in 100°C increments and subsequently analyzed with the SEM-EDX to determine the atomic percentage of present elements. Three-factor ANOVA analysis showed that neither the exposure temperature, nor whether the burning occurred with or without soft tissue present had any significant influence on the bone's overall elemental makeup (p > 0.05). The Ca/P ratio remained in the osseous typical range of between 1.6 and 2.58 in all analyzed samples. This demonstrates that even faced with high temperatures, the overall gross elemental content and atomic percentage of elements in bone remain stable, creating a unique "fingerprint" for osseous material, even after exposure to extreme conditions. © 2017 American Academy of Forensic Sciences.

  5. The comparison between the prostatic specific antigen and the bone scan in the diagnosis of metastases in operating patients of prostatic cancer. Preliminary report. Comparasion entre antigeno prostatico especifico y gammagrafia osea en el diagnostico de metastasis en pacientes operados por cancer de prostata. Reporte preliminar

    Energy Technology Data Exchange (ETDEWEB)

    Morales, R; Cano P, R; Mendoza P, G [Instituto Peruano de Energia Nuclear, Lima (Peru); Pow S, M [Instituto Nacional de Enfermedades Neoplasicas (Peru)

    1993-03-01

    To compare the value of prostatic specific antigen (PSA) with bone scan results, a study was conducted enrolling 25 prostatic adenocarcinoma patients, fulfilling the following criteria for inclusion: (a) histological confirmation of diagnosis (b) radical prostatectomy at least three months before bone scan as curative therapy (c) at least one month between bone scan and PSA measurement. Fourteen cases were within normal ranges on both techniques. Eleven had metastases on bone scans, with PSA in normal range in five of them. The Spearman's ranks coefficient was rs=0,92, with alfa=0,01, accepting that both tecniques are comparable. (Authors). 10 refs., 1 tab., 2 figs.

  6. Metallic radionuclides: applications in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Weiner, R.E.; Thakur, M.L.

    1995-01-01

    Nuclear Medicine is a medical modality that utilizes radioactivity (radiopharmaceutical) to diagnose and treat disease. Radiopharmaceuticals contain a component which directs the radionuclide to the desire physiological target. For diagnostic applications, these nuclides must emit a γ ray that can penetrate the body and can be detected externally while for therapeutic purposes nuclides are preferred that emit β particles and deliver highly localized tissue damage. 67 Ga citrate is employed to detect chronic occult abscesses, Hodgkin's and non-Hodgkin's lymphomas, lung cancer, hepatoma and melanoma and localizes in these tissues utilizing iron-binding proteins. 201 Thallous chloride, a potassium analogue, used to diagnosis coronary artery disease, is incorporated in muscle tissue via the Na + -K + -ATPase. 111 In labeled autologous white blood cells, used for the diagnosis of acute infections and inflammations, takes advantage of the white cell's role in fighting infections. 111 In is incorporated in other radiopharmaceuticals e.g. polyclonal IgG, OncoScint CR/OV, OctreoScan and Myoscint by coupling diethylenetriaminepentaacetic acid, a chelate, covalently to these molecules. OncoScint CR/OV and Myoscint localize by antigen-antibody interactions while OctreoScan is taken up by malignant cells in a receptor based process. Polyclonal IgG may share some localization characteristics with 67 Ga. 89 Sr, a pure β emitter, is used for palliation of bone pain due to metastatic bone lesions. Bone salts [Ca(PO) 4 ] are increased in these lesions and this radionuclide is taken up similarly to Ca 2+ . 186 Re and 153 Sm bound to polydentate phosphonate chelates are used similarly and follow the phosphate pathway in lesion incorporation. (orig.)

  7. Metallic radionuclides: Applications in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Werner, R.E.; Thakur, M. L.

    1997-01-01

    Nuclear Medicine is a medical modality that utilizes radioactivity (radiopharmaceutical) to diagnose and treat disease. Radiopharmaceuticals contain a component which directs the radionuclide to the desire physiological target. For diagnostic applications, these nuclides must emit a gamma ray that can penetrate the body and can be detected externally while for therapeutic purposes nuclides are preferred that emit beta particles and deliver highly localized tissue damage. sup 6 sup 7 Ga citrate is employed to detect chronic occult abscesses, Hodgkin's and non-Hodgkin's lymphomas, lung cancer, hepatoma and melanoma and localizes in these tissues utilizing iron-binding proteins. sup 2 sup 0 sup 1 Thallous chloride, a potassium analogue, used to diagnosis coronary artery disease, is incorporated in muscle tissue via the Na sup + -K sup + -ATPase. sup 1 sup 1 sup 1 In labeled autologous white blood cells, used for the diagnosis of acute infections and inflammations, takes advantage of the white cell's role in fighting infections. sup 1 sup 1 sup 1 In is incorporated in other radiopharmaceuticals e.g. polyclonal IgG, OncoScint CR/OV, OctreoScan and Myoscint by coupling diethylenetriaminepentaacetic acid, a chelate, covalently to these molecules. OncoScint CR/OV and Myoscint localize by antigen-antibody interactions while OctreoScan is taken up by malignant cells in a receptor based process. Polyclonal IgG may share some localization characteristics with sup 6 sup 7 Ga. sup 8 sup 9 Sr, a pure beta emitter, is used for palliation of bone pain due to metastatic bone lesions. Bone salts [Ca(PO) sub 4] are increased in these lesions and this radionuclide is taken up similarly to Ca sup 2 sup +. sup 1 sup 8 sup 6 Re and sup 1 sup 5 sup 3 Sm bound to polydentate phosphonate chelates are used similarly and follow the phosphate pathway in lesion incorporation. (author)

  8. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran.

    Science.gov (United States)

    Salamat, Mohammad Reza; Salamat, Amir Hossein; Abedi, Iraj; Janghorbani, Mohsen

    2013-01-01

    Objective. Although several studies have investigated the association between body mass index (BMI) and bone mineral density (BMD), the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft) and lumbar vertebrae (L2-L4) using a Dual-Energy X-ray Absorptiometry (DXA) scan and examination of body size. Participants were categorised in two BMI group: normal weight obese, BMI ≥ 25 kg/m(2). Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93) and for osteoporosis was 4.4 (1.51, 12.87) for men with BMI osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  9. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Salamat

    2013-01-01

    Full Text Available Objective. Although several studies have investigated the association between body mass index (BMI and bone mineral density (BMD, the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft and lumbar vertebrae (L2-L4 using a Dual-Energy X-ray Absorptiometry (DXA scan and examination of body size. Participants were categorised in two BMI group: normal weight <25.0 kg/m2 and overweight and obese, BMI ≥ 25 kg/m2. Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93 and for osteoporosis was 4.4 (1.51, 12.87 for men with BMI < 25. It was noted that BMI and weight was associated with a high BMD, compatible with a diagnosis of osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  10. Radionuclide techniques for brain imaging

    International Nuclear Information System (INIS)

    Cowan, R.J.; Moody, D.M.

    1984-01-01

    Over the past decade, many of the prime indications for radionuclide brain scanning have become instead indications for CCT, and nuclear medicine studies of the brain have assumed more of a complementary, supportive role. However, there is great promise for improvement in central nervous system radionuclide applications with advances anticipated in both radiopharmaceuticals and instrumentation. Nuclear medicine is continuing to function as a powerful research tool and, in the relatively near future, may regain its role as a major clinical test of the central nervous system

  11. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  12. A comparison of high resolution CT scan of temporal bone and operative findings in middle ear cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, Tae Beom; Seong, Hun; Cheon, Mal Soon; Kim, Hack Jin; Jang, Keung Jae; Chun, Byung Hee [Dae Dong General Hospital, Busan (Korea, Republic of)

    1993-09-15

    To evaluate the value of HRCT imaging in middle ear cholesteatoma, we prospectively analysed the CT images in 28 surgically proven cases with cholesteatomas regarding main site of lesion, ossicular change, facial nerve exposure and fistula formation. The most common main site of lesion was the epitympanum (92.8%). The results of sensitivity, positive predictability, and accuracy by CT imagings were as follows: for ossicular involvement, 94.1%, 88.8%, and 86.2% in malleus, 96.0%, 88.8%, and 85.7% in incus, 81.2%, 81.2%, and 78.5% in stapes; for facial nerve exposure, 66.6%, 57.1%, and 81.2%: for fistula formation, 100%, 75.0%, and 96.4%, respectively. In conclusion, the temoral bone HRCT imaging is an accurate preoperative method in detecting main lesion site, ossicular involvement, fistula formation. Because of the low sensitivity and positive predictability in detecting facial nerve exposure, it is necessary to correlate the HRCT images with the clinical status.

  13. Exclusion of pneumothorax by radionuclide lung scan

    International Nuclear Information System (INIS)

    Weiss, P.E.

    1986-01-01

    A case is reported in which ventilation lung imaging was useful in excluding a large pneumothorax. This technique may be helpful in patients with emphysema in whom exclusion of pneumothorax by radiographic criteria might be difficult

  14. Therapeutic efficacy and dosimetric aspects of Rhenium-188-HEDP in bone pain palliation

    International Nuclear Information System (INIS)

    Liepe, Knut

    2005-01-01

    Full text: Bone metastases are a frequent complication of cancer, occurring in up 70% of patients suffering from advanced breast or prostate cancer and often present with severe bone pain. In this purpose the radionuclide therapy is a useful option for cancer patients. Different radionuclides are described, such as 89 Sr, 32 P, 153 Sm-EDTMP, 186 Re-HEDP, 131 I-BDP3, 90 Y, 117mSn-DTPA, 188 Re-HEDP and 188 Re-DMSA. The most experiences are available for 89 Sr. An indication for the treatment are patients with osteoblastic metastases, bone pain, sufficient bone marrow function and at least of three bone metastases visualized in bone scan. A bisphosphonate therapy, a chemotherapy with lower bone marrow toxicity or a local field external beam radiotherapy represent no contraindications, especially because the reported synergistic effects to the systemic radionuclide therapy. In 33 treated patients (breast and prostate cancer) we investigated the effect of 188 Re-HEDP on pain relief, analgesic intake and impairment of bone marrow function. There were an improvement on the Karnofsky performance scale from 74 7% to 85 9% 12 weeks after therapy (p= 0.001). The pain score showed a maximum decrease from 44 ± 18% to 27 ± 20% in the 3rd to the 8th week after therapy (p = .009) and 76% had a pain relief (20% were pain free). The maximal differences between the values of platelets and leukocytes before and after therapy were not statistically significant (p = 0.021 and p = 0.094). In 105 investigated patients treated with different radionuclides ( 89 Sr, 153 Sm-EDTMP, 186 Re-HEDP, 188 Re-HEDP and 89 Sr in combination with chemotherapy) no different therapeutic efficacy of the treatments were observed. In dose calculation of 188 Re-HEDP a radiation dose of 3.83 ± 2.01 mGy/MBq (12.6 Gy for 3300 MBq) for bone metastases and 0.61 ± 0.21 mGy/MBq (2 Gy for 3300 MBq) were found. With the introducing of radionuclide treatments with chemotherapy and repeated treatments, the

  15. 18-F flourodeoxy glucose positron emission tomography-computed tomography imaging: A viable alternative to three phase bone scan in evaluating diabetic foot complications?

    International Nuclear Information System (INIS)

    Shagos, G. S.; Shanmugasundaram, Palaniswamy; Varma, Ajith Kumar; Padma, Subramanyam; Sarma, Manjit

    2015-01-01

    This paper is based on the initial findings from a prospective ongoing study to evaluate the efficacy of flourodeoxy glucose positron emission tomography-computed tomography (FDG-PET CT) in diabetic foot evaluation. The aim was to compare the diagnostic accuracies of three phase bone scan (TPBS) and FDG PET-CT (FDG-PET) in diabetic foot evaluation. Seventy-nine patients with complicated diabetic foot (osteomyelitis/cellulitis, Charcot's neuropathy) were prospectively investigated. TPBS (15 mci methylene di phosphonate [MDP] intravenous [IV]), followed by FDG-PET (5 mci IV) within 5 days were performed in all patients. Based on referral indication, patients grouped into Group I, n = 36, (?osteomyelitis/cellulitis) and Group II, n = 43 (?Charcot's neuropathy). Interpretation was based on intensity, extent, pattern of MDP and FDG uptake (standardized uptake value) along with CT correlation. Findings were compared with final diagnostic outcome based on bone/soft tissue culture in Group I and clinical, radiological or scintigraphic followup in Group II. Results: Group I: For diagnosing osteomyelitis, TP: TN: FP: FN were 14:5:2:2 by FDG PET and 13:02:05:03 by TPBS respectively. Sensitivity, specificity, positive predictive value and negative predictive value (NPV) of FDG-PET were 87.5%, 71%, 87.5% and 71% and 81.25%, 28.5%, 72% and 40% for TPBS, respectively. Group II: charcot's: cellulitis: Normal were 22:14:7 by FDG PET and 32:5:6 by TPBS, respectively. Flourodeoxy glucose PET-CT has a higher specificity and NPV than TPBS in diagnosing pedal osteomyelitis. TPBS, being highly sensitive is more useful than FDG-PET in detecting Charcot's neuropathy

  16. Radiopharmaceuticals for bone scintillators

    International Nuclear Information System (INIS)

    Rey, A.M.

    1994-01-01

    One of the diagnostic techniques used in nuclear medicine is the bone scintiscanning with labelled compounds for obtain skeletal images. The main sections in this work are: (1) bone composition and anatomy;(2)skeletal radiopharmaceutical development;(3)physical properties of radionuclides;(4)biological behaviour and chemical structures;(5)radiopharmaceuticals production for skeletal scintillation;(6)kits;(7)dosimetry and toxicity.tabs

  17. Radionuclide transverse section imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1980-01-01

    A radioisotope scanning apparatus for use in nuclear medicine is described in detail. The apparatus enables the quantification and spatial location of the radioactivity in a body section of a patient to be determined with high sensitivity. It consists of an array of highly focussed collimators arranged such that adjacent collimators move in the same circumferential but opposite radial directions. The explicit movements of the gantry are described in detail and may be controlled by a general purpose computer. The use of highly focussed collimators allows both a reasonable solid angle of acceptance and also high target to background images; additionally, dual radionuclide pharmaceutical studies can be performed simultaneously. It is claimed that the high sensitivity of the system permits the early diagnosis of pathological changes and the images obtained show accurately the location and shape of physiological abnormalities. (UK)

  18. Stabilized radiographic scanning agents

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1982-01-01

    Stable compositions useful as technetium 99m-based scintigraphic agents comprise gentisic acid or a pharmaceutically-acceptable salt or ester thereof in combination with a pertechnetate reducing agent or dissolved in pertechnetate-99m (sup(99m)TcOsub(4)sup(-)) solution. The compositions are especially useful in combination with a phosphate or phosphonate material that carries the radionuclide to bone, thus providing a skeletal imaging agent

  19. Incidental diagnosis of pregnancy on bone and gallium scintigraphy

    International Nuclear Information System (INIS)

    Palestro, C.J.; Malat, J.; Collica, C.J.; Richman, A.H.

    1986-01-01

    Bone and gallium scintigraphy were performed as part of the diagnostic workup of a 21-yr-old woman who presented at our institution with a history of progressively worsening low back pain over a 1-wk period of time. The angiographic phase of the bone scan demonstrated a well-defined radionuclide blush within the pelvis just cephalad to the urinary bladder with persistent hyperemia noted in the blood-pool image. We attribute these findings to a uterine blush secondary to the pronounced uterine muscular hyperplasia, hyperemia, and edema that accompany pregnancy. Gallium scintigraphy demonstrated intense bilateral breast accumulation of the imaging agent in a typical doughnut pattern which is commonly found in the prelactating and lactating breast. Also demonstrated was apparent gallium accumulation in the placenta. This case is presented to emphasize the radionuclide findings that occur during pregnancy, particularly the incidental finding of radionuclide blush during the angiographic phase of a radionuclide scintigraphy which should alert the nuclear physician to the possibility of pregnancy in a woman of childbearing age

  20. TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

    Energy Technology Data Exchange (ETDEWEB)

    Perk, T; Bradshaw, T; Muzahir, S; Jeraj, R [University of Wisconsin, Madison, Wisconsin (United States); Meyer, E [Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2014-06-15

    Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate

  1. TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

    International Nuclear Information System (INIS)

    Perk, T; Bradshaw, T; Muzahir, S; Jeraj, R; Meyer, E

    2014-01-01

    Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate

  2. Extraosseous accumulation of bone scanning agents in malignant brain tumors. Comparison to semi-quantitative evaluation with 99mTc SPECT/201Tl SPECT and histological findings

    International Nuclear Information System (INIS)

    Suzuki, Aya

    2003-01-01

    Although 201 Tl chloride (Tl) SPECT has been used in the differential diagnosis between recurrence of malignant brain tumor and necrosis after treatment, it is not generally recognized as a definite modality to distinguish them. We conducted a preliminary study using Tl SPECT and 99m Tc-MDP or 99m Tc-HMDP (Tc) SPECT because it has been said that extraosseous accumulation was caused by calcium deposits in necrotic tissues. In our study, for the purposes of clarifying the mechanism of extraosseous uptake and the correlation between extraosseous accumulation of bone-scanning agent and tumor viability in malignant brain tumors, we compared whether Tc uptake was correlated with the histopathological findings and further performed semi-quantitative evaluation between Tc SPECT and Tl SPECT. The correlation coefficients between the ratio of tumor to normal skull count obtained from Tc SPECT (Tc-T/N) and those of tumor to normal brain count (T/N) and to normal scalp count (T/S) both obtained from Tl SPECT were calculated. Using contrast enhanced CT (CE-CT) or contrast enhanced MRI (CE-MRI), 8 of 10 cases showed intensely ring-enhanced tumor with necrotic lesion. Histopathologically, 7 of 8 cases whose tumor had been resected before treatment had necrosis with increased vascularity or bleeding. Of the remaining 2 cases one case, malignant lymphoma had