WorldWideScience

Sample records for radiological performance objectives

  1. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  2. Introduction to radiological performance assessment

    International Nuclear Information System (INIS)

    Moss, G.

    1995-02-01

    A radiological performance assessment is conducted to provide reasonable assurance that performance objectives for low-level radioactive waste (LLW) disposal will be met. Beginning in the early stages of development, a radiological performance assessment continues through the operational phase, and is instrumental in the postclosure of the facility. Fundamental differences exist in the regulation of commercial and defense LLW, but the radiological performance assessment process is essentially the same for both. The purpose of this document is to describe that process in a concise and straightforward manner. This document focuses on radiological performance assessment as it pertains to commercial LLW disposal, but is applicable to US Department of Energy sites as well. Included are discussions on performance objectives, site characterization, and how a performance assessment is conducted. A case study is used to illustrate how the process works as a whole. A bibliography is provided to assist in locating additional information

  3. The use of Leeds Test Objects in the assessment of the performance of radiological imaging systems: an introduction

    International Nuclear Information System (INIS)

    Cowen, A.R.

    1986-01-01

    Over the preceding decade the Leeds Radiological Imaging Group have developed a range of test objects with which to assess the performance of radiological imaging systems. The types of imaging equipment which can be assessed include X-ray image intensifier television systems, small-format 100mm/105mm fluorography systems and radiographic screen-film combinations. We have recently extended our interest to the evaluation of digital radiological imaging equipment including digital subtraction fluorography and digital (greyscale) radiographic imaging systems. These test objects were initially developed for the purpose of evaluating imaging performance under laboratory conditions but they have also proved useful under field (clinical) conditions. (author)

  4. Radiological characterisation - Know your objective

    International Nuclear Information System (INIS)

    Lindow, Veronica; Moeller, Jennifer

    2012-01-01

    When developing a programme for mapping the radiological characteristics of a facility to be decommissioned it is important to take into account the objectives of the programme. Will the results be used to plan for radiological control and selection of appropriate decontamination and dismantling techniques? Will the radiological inventory be used for dimensioning of future waste repositories? These are two examples of the applications for such studies, which could require that a radiological characterisation programme be adapted to provide the data appropriate to the intended use. The level of detail and scope needed for a radiological characterisation will also vary depending on how the data will be used. An application to free-release a facility requires a comprehensive survey and well documented analysis in order to ensure that no radioactive contamination above prescribed levels is present. A bounding calculation to determine the maximum anticipated volumes and activity of radioactive waste requires a different approach. During the past few years, older decommissioning studies for the Swedish nuclear power plants have been updated (or are in the process of being updated). The decommissioning study's main purpose is to estimate the cost for decommissioning. The cost estimation is based on material and activity inventories, which in turn is based on previous and, in some cases, updated radiological characterisations of the facilities. The radiological inventory is an important part of the study as it affects the cost of decommissioning but also the uncertainties and accuracy of the cost estimation. The presentation will discuss the challenges in specifying a radiological characterisation programme with multiple objectives, together with insights on how data delivered can be applied to yield results suitable for the intended purpose, without introducing excessive conservatism. The intent of the presentation is to define issues that can be of use in various aspects

  5. Radiological protection objectives for the disposal of solid radioactive wastes

    International Nuclear Information System (INIS)

    1983-10-01

    Guidance is given on the standards to be used in the UK in decisions on the radiological acceptability of disposal methods for solid radioactive wastes. The radiological protection objectives given in the report are intended to be applied to all types of solid radioactive waste, and to all the disposal methods which are in use or under consideration. This guidance complements and extends previous Board advice on radiological protection objectives which apply to the control of routine discharges of gaseous and liquid effluents. (author)

  6. Radiology as part of an objective structured clinical examination on clinical skills

    International Nuclear Information System (INIS)

    Berk, I.A.H. van den; Ridder, J.M.M. van de; Schaik, J.P.J. van

    2011-01-01

    Introduction: An objective structured clinical examination (OSCE) assessess clinical competence in a standardised and context related manner. Compared with written tests, OSCE's are more susceptible to reliability errors because of the use of multiple cases and multiple examiners. In the pre-clinical phase of the medical curriculum of the University Medical Centre Utrecht, an OSCE is organised as a medical consult. We evaluated the radiology station. Method: Four questions were formulated: ·What is the internal consistency of the items of the radiology station? ·How do the scores on the radiology station compare with the scores on the test excluding radiology? ·How do different cases differ in scores? ·What are the differences in score between the examiners? We analysed the OSCE results of second year medical students in 2004. Results: Two hundred and sixty-five students were examined in the OSCE in 2004. Ninty-three Students were examined in the radiology station. Cronbach's alpha coefficient for the radiology station was 0.92. The average score for the radiology station was 3.8 (0.87). The average score for the test without radiology was 3.9 (0.32). The range of the average scores for the six different cases was 0.5 (3.6-4.1). The range of the average scores for the five examiners was 1.0 (3.3-4.3). Conclusion: The internal consistency of the items in the radiology station is good. The average score for the radiology station is similar to that of the other stations. The range of the scores between the different cases was relatively small. The range of the scores between the different examiners was clearly larger.

  7. Radiology reports: a quantifiable and objective textual approach

    International Nuclear Information System (INIS)

    Scott, J.A.; Palmer, E.L.

    2015-01-01

    Aim: To examine the feasibility of using automated lexical analysis in conjunction with machine learning to create a means of objectively characterising radiology reports for quality improvement. Materials and methods: Twelve lexical parameters were quantified from the collected reports of four radiologists. These included the number of different words used, number of sentences, reading grade, readability, usage of the passive voice, and lexical metrics of concreteness, ambivalence, complexity, passivity, embellishment, communication and cognition. Each radiologist was statistically compared to the mean of the group for each parameter to determine outlying report characteristics. The reproducibility of these parameters in a given radiologist's reporting style was tested by using only these 12 parameters as input to a neural network designed to establish the authorship of 60 unknown reports. Results: Significant differences in report characteristics were observed between radiologists, quantifying and characterising deviations of individuals from the group reporting style. The 12 metrics employed in a neural network correctly identified the author in each of 60 unknown reports tested, indicating a robust parametric signature. Conclusion: Automated and quantifiable methods can be used to analyse reporting style and provide impartial and objective feedback as well as to detect and characterise significant differences from the group. The parameters examined are sufficiently specific to identify the authors of reports and can potentially be useful in quality improvement and residency training. - Highlights: • Radiology reports can be objectively studied based upon their lexical characteristics. • This analysis can help establish norms for reporting, resident training and authorship attribution. • This analysis can complement higher level subjective analysis in quality improvement efforts.

  8. Radiology as part of an objective structured clinical examination on clinical skills

    Energy Technology Data Exchange (ETDEWEB)

    Berk, I.A.H. van den, E-mail: i.a.h.van_den_berk@lumc.nl [Department of Radiology, Leiden University Medical Centre, Postbus 9600, 2300 RC Leiden (Netherlands); Ridder, J.M.M. van de, E-mail: J.M.M.vandeRidder@umcutrecht.nl [School of Medical Sciences, University Medical Centre Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Schaik, J.P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Department of Radiology, University Medical Centre Utrecht, Heidelberglaan 100 E01-132, 3584 CX Utrecht (Netherlands)

    2011-06-15

    Introduction: An objective structured clinical examination (OSCE) assessess clinical competence in a standardised and context related manner. Compared with written tests, OSCE's are more susceptible to reliability errors because of the use of multiple cases and multiple examiners. In the pre-clinical phase of the medical curriculum of the University Medical Centre Utrecht, an OSCE is organised as a medical consult. We evaluated the radiology station. Method: Four questions were formulated: {center_dot}What is the internal consistency of the items of the radiology station? {center_dot}How do the scores on the radiology station compare with the scores on the test excluding radiology? {center_dot}How do different cases differ in scores? {center_dot}What are the differences in score between the examiners? We analysed the OSCE results of second year medical students in 2004. Results: Two hundred and sixty-five students were examined in the OSCE in 2004. Ninty-three Students were examined in the radiology station. Cronbach's alpha coefficient for the radiology station was 0.92. The average score for the radiology station was 3.8 (0.87). The average score for the test without radiology was 3.9 (0.32). The range of the average scores for the six different cases was 0.5 (3.6-4.1). The range of the average scores for the five examiners was 1.0 (3.3-4.3). Conclusion: The internal consistency of the items in the radiology station is good. The average score for the radiology station is similar to that of the other stations. The range of the scores between the different cases was relatively small. The range of the scores between the different examiners was clearly larger.

  9. Simplified production of multimedia based radiological learning objects using the flash format

    International Nuclear Information System (INIS)

    Jedrusik, P.; Preisack, M.; Dammann, F.

    2005-01-01

    Purpose: evaluation of the applicability of the flash format for the production of radiological learning objects used in an e-learning environment. Material and methods: five exemplary learning objects with different didactic purposes referring to radiological diagnostics are presented. They have been intended for the use within the multimedia, internet-based e-learning environment LaMedica. Interactive learning objects were composed using the Flash 5.0 software (Macromedia, San Francisco, USA) on the basis of digital CT and MR images, digitized conventional radiographs and different graphical elements prepared as TIFF files or in a vector graphics format. Results: after a short phase of initial skill adaptation training, a radiologist author was soon able to create independently all learning objects. The import of different types of images and graphical elements was carried out without complications. Despite manifold design options, handling of the program is easy due to clear arrangement and structure, thus enabling the creation of simple as well as complex learning objects that provided a high degree of attractiveness and interaction. Data volume and bandwidth demand for online use was significantly reduced by the flash format compression without a substantial loss of visual quality. (orig.)

  10. Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Site

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Meier, Kirsten M.; Snyder, Sandra F.; Fritz, Brad G.; Poston, Ted M.; Rhoads, Kathleen

    2010-05-25

    This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006) as well as several other published DQOs. Pacific Northwest National Laboratory (PNNL) is in the process of developing a radiological air monitoring program for the PNNL Site that is distinct from that of the nearby Hanford Site. Radiological emissions at the PNNL Site result from Physical Sciences Facility (PSF) major emissions units. A team was established to determine how the PNNL Site would meet federal regulations and address guidelines developed to monitor and estimate offsite air emissions of radioactive materials. The result is a program that monitors the impact to the public from the PNNL Site.

  11. Radiological performance assessment for the Z-Area Saltstone Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Cook, J.R.; Fowler, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States)

    1992-12-18

    This radiological performance assessment (RPA) for the Savannah River Site (SRS) Saltstone Disposal Facility (SDF) was prepared in accordance with the requirements of Chapter III of the US Department of Energy Order 5820.2A. The Order specifies that an RPA should provide reasonable assurance that a low-level waste (LLW) disposal facility will comply with the performance objectives of the Order. The performance objectives require that: (1) exposures of the general public to radioactivity in the waste or released from the waste will not result in an effective dose equivalent of 25 mrem per year; (2) releases to the atmosphere will meet the requirements of 40 CFR 61; (3) inadvertent intruders will not be committed to an excess of an effective dose equivalent of 100 mrem per year from chronic exposure, or 500 mrem from a single acute exposure; and (4) groundwater resources will be protected in accordance with Federal, State and local requirements.

  12. Radiological performance assessment for the Z-Area Saltstone Disposal Facility

    International Nuclear Information System (INIS)

    Cook, J.R.; Fowler, J.R.

    1992-01-01

    This radiological performance assessment (RPA) for the Savannah River Site (SRS) Saltstone Disposal Facility (SDF) was prepared in accordance with the requirements of Chapter III of the US Department of Energy Order 5820.2A. The Order specifies that an RPA should provide reasonable assurance that a low-level waste (LLW) disposal facility will comply with the performance objectives of the Order. The performance objectives require that: (1) exposures of the general public to radioactivity in the waste or released from the waste will not result in an effective dose equivalent of 25 mrem per year; (2) releases to the atmosphere will meet the requirements of 40 CFR 61; (3) inadvertent intruders will not be committed to an excess of an effective dose equivalent of 100 mrem per year from chronic exposure, or 500 mrem from a single acute exposure; and (4) groundwater resources will be protected in accordance with Federal, State and local requirements

  13. Guidelines for radiological performance assessment of DOE low-level radioactive waste disposal sites

    International Nuclear Information System (INIS)

    Case, M.J.; Otis, M.D.

    1988-07-01

    This document provides guidance for conducting radiological performance assessments of Department of Energy (DOE) low-level radioactive waste (LLW) disposal facilities. The guidance is specifically intended to provide the fundamental approach necessary to meet the performance assessment requirements. The document is written for LLW facility operators or other personnel who will manage the performance assessment task. The document is meant to provide guidance for conducting performance assessments in a generally consistent manner at all DOE LLW disposal facilities. The guidance includes a summary of performance objectives to be met by LLW disposal facilities (these objectives are derived from current DOE and other applicable federal regulatory guidelines); specific criteria for an adequate performance assessment and from which a minimum set of required calculations may be determined; recommendations of methods for screening critical components of the analysis system so that these components can be addressed in detail; recommendations for the selection of existing models and the development of site-specific models; recommendations of techniques for comparison of assessment results with performance objectives; and a summary of reporting requirements

  14. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi; Oudkerk, Matthijs; van Ooijen, Peter

    2015-01-01

    Objective To evaluate the usability of a radiology workstation after deployment in a hospital. Significance In radiology, it is difficult to perform valid pre-deployment usability evaluations due to the heterogeneity of the user group, the complexity of the radiological workflow, and the complexity

  15. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  16. Radioactive Waste Management Complex low-level waste radiological performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.

    1994-04-01

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.

  17. Radioactive Waste Management Complex low-level waste radiological performance assessment

    International Nuclear Information System (INIS)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.

    1994-04-01

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected

  18. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  19. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  20. Development of radiological performance indicators for nuclear power plants

    International Nuclear Information System (INIS)

    Lee, B.S.; Jung, K.H.; Lee, S.H.; Jang, S.Y.

    2000-01-01

    The purpose of this work was to improve the regulatory approach to check the licensee's compliance with regulation regarding radiation protection in operating nuclear power plants (NPPs). The current domestic inspection program for NPPs requires inspectors to conduct compliance-inspection for the systems/equipment and the procedures of NPPs. In this work, we have developed a set of draft radiological performance indicators (PIs) to assess radiation safety in NPPs. The development of PIs was based on the concept that the licensees' implementation of the radiation protection program in NPPs should be able to achieve the goal of radiation protection which the International Commission on Radiological Protection (ICRP) has recommended as ICRP 60 (1991). We selected and/or developed the radiological performance indicators considering the radiation exposure network (source-environment-receptor) for NPPs. The PIs intend to be applied only to normal exposure due to normal operations including transient operational conditions, but not to potential exposure due to accidents. Also, we have chosen the receptor as workers who are occupationally exposed to radiation as well as the members of public who are exposed to radiation from radioactive effluents. The PIs intend to track the past performance rather than to expect the future performance. Finally, the individual PIs do not verify the root cause of the trend of performance; however, they provide the basis for deciding whether the procedures and work management have been properly implemented. Currently a set of 21 draft PIs has been developed for the exposure network in NPPs. For the receptor, the PIs are divided into worker individual dose, worker collective dose and public individual dose. For the environment, the PIs are related to the dose rates of controlled areas, radioactive material concentrations in controlled areas, radioactive contamination in controlled areas and at exit points, and radioactive effluent

  1. Virtual Raters for Reproducible and Objective Assessments in Radiology

    Science.gov (United States)

    Kleesiek, Jens; Petersen, Jens; Döring, Markus; Maier-Hein, Klaus; Köthe, Ullrich; Wick, Wolfgang; Hamprecht, Fred A.; Bendszus, Martin; Biller, Armin

    2016-04-01

    Volumetric measurements in radiologic images are important for monitoring tumor growth and treatment response. To make these more reproducible and objective we introduce the concept of virtual raters (VRs). A virtual rater is obtained by combining knowledge of machine-learning algorithms trained with past annotations of multiple human raters with the instantaneous rating of one human expert. Thus, he is virtually guided by several experts. To evaluate the approach we perform experiments with multi-channel magnetic resonance imaging (MRI) data sets. Next to gross tumor volume (GTV) we also investigate subcategories like edema, contrast-enhancing and non-enhancing tumor. The first data set consists of N = 71 longitudinal follow-up scans of 15 patients suffering from glioblastoma (GB). The second data set comprises N = 30 scans of low- and high-grade gliomas. For comparison we computed Pearson Correlation, Intra-class Correlation Coefficient (ICC) and Dice score. Virtual raters always lead to an improvement w.r.t. inter- and intra-rater agreement. Comparing the 2D Response Assessment in Neuro-Oncology (RANO) measurements to the volumetric measurements of the virtual raters results in one-third of the cases in a deviating rating. Hence, we believe that our approach will have an impact on the evaluation of clinical studies as well as on routine imaging diagnostics.

  2. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  3. Idaho National Engineering Laboratory Radiological Control performance indicator report: First quarter, calendar year 1995

    International Nuclear Information System (INIS)

    Aitken, S.B.

    1995-07-01

    The INEL Radiological Control Performance Indicator Report is provided quarterly, inaccordance with Article 133 of the INEL Radiological Control Manual. Indicators are used as a measure of performance of the Radiological Control Program and as a motivation for improvement, not as a goal in themselves. These indicators should be used by management to assist in focusing priorities and attention and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. The ALARA Committees establish ALARA goals for the INEL based on forecasts and goals provided by each facility organizational manager or supervisor.Performance goals are realistic and measurable. Stringent goals are set at least annually to reflect expected workloads and improvement of radiological performance. Goals higher than previous goals may occasionally be set due to changes in work scope or mission. The INEL Radiological Control Performance Indicators consist of: Collective dose in person-rem; average worker dose, maximum dose to a worker, and maximum neutron dose to a worker;the number of skin and clothing contaminations, including the number of contaminated wounds and facial contaminations; the number of radioactive material intakes; the area of Contamination, High Contamination, and Airborne Radioactivity Areas in square feet; and airborne radioactivity events and spills

  4. The radiological installation in dental office: selection and performance

    International Nuclear Information System (INIS)

    Cirre, Christian

    2010-01-01

    This thesis for a PhD in dental surgery aimed at identifying and analysing different ways to optimise radiographs. In a first part, the author presents the characteristics of X rays, and dosimetric values used in dental offices. He describes the interaction of X rays with living cells by recalling the discovery of biological effects and the emergence of radiation protection, and by discussing the consequences for the patient as well as for the practician. In the next part, the author comments technological advances of devices, and means available to practicians to improve their performance. He presents X ray tubes, discusses factors which influence ray production, and selection criteria, indicates additional devices (beam application tubes, filtration, collimation), discusses the selection of the receiver (types of receivers used in intra-oral radiology, digital or silver film-based sensors), and describes the picture-taking process (radiological techniques, use of angulators and lead shielding). He finally discusses how to optimise intra-oral dental imagery through good practices which comprise optimisation, selection of apparatuses and devices, performance of the radiological act with a patient sitting in the armchair, and maintenance of a good image quality [fr

  5. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  6. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  7. The Role of Radiological Protection in Sweden's National Environmental quality Objectives

    International Nuclear Information System (INIS)

    Hubbard, L.; Mjones, L.; Holm, E.

    2004-01-01

    In 1999, the Swedish Parliament adopted fifteen environmental quality objectives, defining the quality of Sweden's environment and of its natural and cultural resources that will insure sustainable growth. In 2001, the government proposed interim targets for each objective, specifying the direction and time scale of the proposed actions. These objectives give Sweden a unique opportunity to define, quantify and achieve an ecologically sustainable environment. One of the national objectives, A Safe Radiation Environment, targets both ionising and non-ionising radiation and states, human health and biological diversity must be protected against the harmful effects of radiation in the environment. The Swedish Radiation Protection Authority (SSI) has the responsibility for formulating and achieving the interim targets for this objective. The targets presently focus on controlling radioactive emissions, limiting exposures to ultraviolet radiation and defining the risks from exposure to electromagnetic fields. Part of SSI's responsibility for the environmental quality objective is to develop a system for monitoring and quantifying progress towards each interim target. Sweden's National Board of Housing, Building and Planning (NBHBP) is responsible for another of the national objectives, A Good Built- Environment. As part of this objective, a special interim target for the indoor environment was approved by Parliament in 2002, which includes a specification for human exposure to radon in indoor air. It states: radon concentrations should be lower than 200 Bq/m3 in schools and pre-schools by the year 2010, and below 200 Bq/m3 in homes by 2020. This substantially raises the level of ambition regarding reducing exposure to indoor radon. The aim of this paper is to briefly summarize the role of radiological protection in Sweden's environmental quality objectives. (Author) 3 refs

  8. Radiological studies on Egyptian mummies

    International Nuclear Information System (INIS)

    Pahl, W.M.

    1982-01-01

    The goal of this work as part of a mummy study project is to obtain the maximum amount of information through radiological methods with the minimum destruction of the object. For this proven radiological methods were used as well as conventional radiological methods which had not yet been used with mummy research and modern radiological methods using an electronic basis relative to their importance for the study of medical archaeological materials. It is shown that the knowledge which is gained from the use of a combination of classical radiological methods and computed tomography cannot be enhanced by an autopsy of the study objects. Since because of this the objects can be kept in their original condition, a later checking of the results is guaranteed with the possibility of clearing up remaining open questions by means of further developed methods. (orig.) [de

  9. Objective indicators of organizational performance at nuclear power plants

    International Nuclear Information System (INIS)

    Olson, J.; Osborn, R.N.; Jackson, D.H.; Shikiar, R.

    1986-01-01

    This report summarizes research conducted on the development and validation of organizational performance measures at operating nuclear power plants. Publicly available data, including measures from Licensee Event Reports, operating and outage data, and violations data, are used to predict penultimate measures of plant safety. Penultimate measures of safety include potentially significant events, overexposures and near overexposures, and several radiological release measures. The 1981 and 1982 performance measures are used in correlation and regression analyses to predict performance on the penultimate safety measures in 1982 and 1983. Many of the plant performance measures are consistently predictive of the frequency of potentially significant events. No strong, consistent predictors emerge for exposures or liquid radiological releases. Several performance measures are consistent predictors of gaseous releases. The regression analyses indicate that the predictors do not tend to combine in consistent, multivariate patterns, and controls for plant age, size, type, region, and fuel cycle stage do not substantially affect the results. The analysis concludes that existing performance data do appear to be predictive of some aspects of plant safety performance. The report recommends that more reliable, summary performance measures be created by combining several of the performance measures tested in the current analysis

  10. Radiological error: analysis, standard setting, targeted instruction and teamworking

    International Nuclear Information System (INIS)

    FitzGerald, Richard

    2005-01-01

    Diagnostic radiology does not have objective benchmarks for acceptable levels of missed diagnoses [1]. Until now, data collection of radiological discrepancies has been very time consuming. The culture within the specialty did not encourage it. However, public concern about patient safety is increasing. There have been recent innovations in compiling radiological interpretive discrepancy rates which may facilitate radiological standard setting. However standard setting alone will not optimise radiologists' performance or patient safety. We must use these new techniques in radiological discrepancy detection to stimulate greater knowledge sharing, targeted instruction and teamworking among radiologists. Not all radiological discrepancies are errors. Radiological discrepancy programmes must not be abused as an instrument for discrediting individual radiologists. Discrepancy rates must not be distorted as a weapon in turf battles. Radiological errors may be due to many causes and are often multifactorial. A systems approach to radiological error is required. Meaningful analysis of radiological discrepancies and errors is challenging. Valid standard setting will take time. Meanwhile, we need to develop top-up training, mentoring and rehabilitation programmes. (orig.)

  11. A Business Analytics Software Tool for Monitoring and Predicting Radiology Throughput Performance.

    Science.gov (United States)

    Jones, Stephen; Cournane, Seán; Sheehy, Niall; Hederman, Lucy

    2016-12-01

    Business analytics (BA) is increasingly being utilised by radiology departments to analyse and present data. It encompasses statistical analysis, forecasting and predictive modelling and is used as an umbrella term for decision support and business intelligence systems. The primary aim of this study was to determine whether utilising BA technologies could contribute towards improved decision support and resource management within radiology departments. A set of information technology requirements were identified with key stakeholders, and a prototype BA software tool was designed, developed and implemented. A qualitative evaluation of the tool was carried out through a series of semi-structured interviews with key stakeholders. Feedback was collated, and emergent themes were identified. The results indicated that BA software applications can provide visibility of radiology performance data across all time horizons. The study demonstrated that the tool could potentially assist with improving operational efficiencies and management of radiology resources.

  12. Key Performance Indicators in Radiology: You Can't Manage What You Can't Measure.

    Science.gov (United States)

    Harvey, H Benjamin; Hassanzadeh, Elmira; Aran, Shima; Rosenthal, Daniel I; Thrall, James H; Abujudeh, Hani H

    2016-01-01

    Quality assurance (QA) is a fundamental component of every successful radiology operation. A radiology QA program must be able to efficiently and effectively monitor and respond to quality problems. However, as radiology QA has expanded into the depths of radiology operations, the task of defining and measuring quality has become more difficult. Key performance indicators (KPIs) are highly valuable data points and measurement tools that can be used to monitor and evaluate the quality of services provided by a radiology operation. As such, KPIs empower a radiology QA program to bridge normative understandings of health care quality with on-the-ground quality management. This review introduces the importance of KPIs in health care QA, a framework for structuring KPIs, a method to identify and tailor KPIs, and strategies to analyze and communicate KPI data that would drive process improvement. Adopting a KPI-driven QA program is both good for patient care and allows a radiology operation to demonstrate measurable value to other health care stakeholders. Copyright © 2015 Mosby, Inc. All rights reserved.

  13. Device for direct digitized radiology of small objects

    International Nuclear Information System (INIS)

    Thomas, G.; Favier, C.; Brebant, C.; Mogavero, R.

    1983-06-01

    A radiological device has been developed to obtain direct digitized views with a large integration time. A micro computer system with programs specially developed for the automatic materials defects evaluation is used. Some results concerning the weldings of electro-nuclear fuel pins are presented here [fr

  14. Technical basis for the performance of radiological surveys in support of nuclear facility decommissioning/deactivation utilizing the Laser-Assisted Ranging and Data System (LARADS)

    International Nuclear Information System (INIS)

    Wade, C.D.

    1997-06-01

    This document describes the implementation of the Laser-Assisted Ranging and Data System (LARADS) as it applies to performing radiological surveys on facility exterior and interior surfaces. The LARADS enables the system operator to document scanning measurements, stationary radiological measurements, and sample locations of surfaces, with the radiological readings and exact coordinates (<2 cm [0.8 in.] precision) automatically logged in real-time. After the survey is completed, the information is downloaded to a geographical information system, and the radiological information is overlaid on a digital picture of the survey area or may be generated as a computer- aided drafted drawing. The final product is a track map or contour of the survey area that clearly shows the area covered by the detector and the locations of elevated readings. The exact reproducibility of data facilitates locating hot spots for remediation and provides for objective review by regulators and verifiers

  15. Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia

    International Nuclear Information System (INIS)

    Profili, Stefano; Manca, Antonio; Feo, Claudio F.; Padua, Guglielmo; Ortu, Riccardo; Canalis, Giulio C.; Meloni, Giovanni B.

    2007-01-01

    Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technical success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated

  16. Fine tuning of work practices of common radiological investigations performed using computed radiography system

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Timothy Peace, B.S.; Sunny, S.; Victor Raj, D.

    2007-01-01

    Introduction: The advent of the computed radiography (CR) has brought about remarkable changes in the field of diagnostic radiology. A relatively large cross-section of the human population is exposed to ionizing radiation on account of common radiological investigations. This study is intended to audit radiation doses imparted to patients during common radiological investigations involving the use of CR systems. Method: The entrance surface doses (ESD) were measured using thermoluminescent dosimeters (TLD) for various radiological investigations performed using the computed radiography (CR) systems. Optimization of radiographic techniques and radiation doses was done by fine tuning the work practices. Results and conclusion: Reduction of radiation doses as high as 47% was achieved during certain investigations with the use of optimized exposure factors and fine-tuned work practices

  17. Probabilistic Radiological Performance Assessment Modeling and Uncertainty

    Science.gov (United States)

    Tauxe, J.

    2004-12-01

    A generic probabilistic radiological Performance Assessment (PA) model is presented. The model, built using the GoldSim systems simulation software platform, concerns contaminant transport and dose estimation in support of decision making with uncertainty. Both the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Department of Energy (DOE) require assessments of potential future risk to human receptors of disposal of LLW. Commercially operated LLW disposal facilities are licensed by the NRC (or agreement states), and the DOE operates such facilities for disposal of DOE-generated LLW. The type of PA model presented is probabilistic in nature, and hence reflects the current state of knowledge about the site by using probability distributions to capture what is expected (central tendency or average) and the uncertainty (e.g., standard deviation) associated with input parameters, and propagating through the model to arrive at output distributions that reflect expected performance and the overall uncertainty in the system. Estimates of contaminant release rates, concentrations in environmental media, and resulting doses to human receptors well into the future are made by running the model in Monte Carlo fashion, with each realization representing a possible combination of input parameter values. Statistical summaries of the results can be compared to regulatory performance objectives, and decision makers are better informed of the inherently uncertain aspects of the model which supports their decision-making. While this information may make some regulators uncomfortable, they must realize that uncertainties which were hidden in a deterministic analysis are revealed in a probabilistic analysis, and the chance of making a correct decision is now known rather than hoped for. The model includes many typical features and processes that would be part of a PA, but is entirely fictitious. This does not represent any particular site and is meant to be a generic example. A

  18. Difficulties of adaptation to Order 453 by radiology services

    International Nuclear Information System (INIS)

    Padilha Filho, L.G.; Chernicharo, C.C.; Montone Junior, V.; Lenine, R.C.; Berquo, F.R.; Koch, H.A.; Costa, V.C.M. da; Rodrigues, I.V.; Duarte, N.S.; Silva, M.O. da

    2001-01-01

    This work has as its objective to present some difficulties of adaptation of a Radiological Service to Order 453, of Health Ministry. The Order 453, gives regulations to use of radiodiagnostic techniques and require the implementation of Quality Assurance Programs in all institution that make use of ionizing radiation. A survey of functioning conditions of General Hospital - Radiological Service of Santa Casa de Misericordia do Rio de Janeiro, was performed with basis on Order 453. After analysis of these conditions, were noticed some needs as, improvement of professional competence about radiation protection and implementation of a Quality Assurance Program in radiological unit of this hospital

  19. Addressing the coming radiology crisis-the Society for Computer Applications in Radiology transforming the radiological interpretation process (TRIP) initiative.

    Science.gov (United States)

    Andriole, Katherine P; Morin, Richard L; Arenson, Ronald L; Carrino, John A; Erickson, Bradley J; Horii, Steven C; Piraino, David W; Reiner, Bruce I; Seibert, J Anthony; Siegel, Eliot

    2004-12-01

    The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.

  20. Research and development in radiological protection

    International Nuclear Information System (INIS)

    Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.

    2004-01-01

    The objective of Radiological Protection is to guarantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information management technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks associated with their definitive management or their release to the environment. Briefly described below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)

  1. A Vertically Integrated Online Radiology Curriculum Developed as a Cognitive Apprenticeship: Impact on Student Performance and Learning.

    Science.gov (United States)

    Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J

    2016-02-01

    The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining

  2. An honest day's work: pay for performance in a pediatric radiology department

    International Nuclear Information System (INIS)

    Bisset, George S.

    2017-01-01

    Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology. (orig.)

  3. Radiological Evaluation Standards in the Radiology Department of Shahid Beheshti Hospital (RAH) YASUJ Based on Radiology standards in 92

    OpenAIRE

    A َKalantari; SAM Khosravani

    2014-01-01

    Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descri...

  4. Physical and cognitive task analysis in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S [School of Psychology, University of Liverpool, Liverpool (United Kingdom); Healey, A [Royal Liverpool University Hospital, Liverpool (United Kingdom); Evans, J [Royal Liverpool University Hospital, Liverpool (United Kingdom); Murphy, M [Royal Liverpool University Hospital, Liverpool (United Kingdom); Crawshaw, M [Department of Psychology, University of Hull, Hull (United Kingdom); Gould, D [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2006-01-15

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  5. Physical and cognitive task analysis in interventional radiology

    International Nuclear Information System (INIS)

    Johnson, S.; Healey, A.; Evans, J.; Murphy, M.; Crawshaw, M.; Gould, D.

    2006-01-01

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model

  6. Objectives of radiological environment protection in nuclear facilities

    International Nuclear Information System (INIS)

    Oberhausen, E.

    1976-01-01

    The aim of the radiological environment protection is to avoid risks to the health of the population. But the risks from radiation can only be considered in connection with spontaneously occuring malignancies. The comparison shows that according to the maximum permissible doses in the German Ordinance of Radiation Protection the risks of radiation injury are so low that they cannot be detected relative to the spontaneous malignancies. (orig.) [de

  7. Preliminary radiological readings on the old uraniferous mining site of Rophin (Puy-de-Dome)

    International Nuclear Information System (INIS)

    Chareyron, Bruno

    2012-01-01

    After a presentation of the site, of the objectives, limits and methodology of the measurement campaign, this document reports and comments the radiological measurements performed by the CRIIRAD on the old uranium mining site of Rophin and its surroundings (gamma radiation). It comments measurements performed 1 meter above the ground and on soils, and anomalies clearly related to past industrial activities. It comments the results of a radiological analysis performed on released waters (uranium 238, radon 222), and on sediments and soils

  8. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Accountable care organizations and radiology: threat or opportunity?

    Science.gov (United States)

    Abramson, Richard G; Berger, Paul E; Brant-Zawadzki, Michael N

    2012-12-01

    Although the anticipated rise of accountable care organizations brings certain potential threats to radiologists, including direct threats to revenue and indirect systemic changes jeopardizing the bargaining leverage of radiology groups, accountable care organizations, and other integrated health care delivery models may provide radiology with an important opportunity to reassert its leadership and assume a more central role within health care systems. Capitalizing on this potential opportunity, however, will require radiology groups to abandon the traditional "film reader" mentality and engage actively in the design and implementation of nontraditional systems service lines aimed at adding differentiated value to larger health care organizations. Important interlinked and mutually reinforcing components of systems service lines, derived from radiology's core competencies, may include utilization management and decision support, IT leadership, quality and safety assurance, and operational enhancements to meet organizational goals. Such systems-oriented service products, tailored to the needs of individual integrated care entities and supported by objective performance metrics, may provide market differentiation to shield radiology from commoditization and could become an important source of new nonclinical revenue. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Radiology education: a radiology curriculum for all medical students?

    NARCIS (Netherlands)

    Zwaan, Laura; Kok, E.M.; van der Gijp, Anouk

    2017-01-01

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some

  11. Determining procedures for simulation-based training in radiology

    DEFF Research Database (Denmark)

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth

    2018-01-01

    , and basic abdominal ultrasound. CONCLUSION: A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. KEY POINTS: • Simulation-based training can supplement training on patients......OBJECTIVES: New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs...... assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. METHODS: A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored...

  12. Radiation Protection Research: Radiological Assessment

    International Nuclear Information System (INIS)

    Zeevaert, T.

    2000-01-01

    The objectives of SCK-CEN's research in the field of radiological impact assessment are (1) to elaborate and to improve methods and guidelines for the evaluation of restoration options for contaminated sites; (2) to develop, test and improve biosphere models for the performance assessment of radioactive waste disposal in near-surface or geological repositories; (3) to asses the impact of releases from nuclear or industrial installations. Main achievements in these areas for 2000 are summarised

  13. Recognition difference and improvement direction of the radiological technologists and patient against medical service in department radiology - Inchon area in the object

    International Nuclear Information System (INIS)

    An, Sung Min; Kim, Sung Chul

    2006-01-01

    Satisfaction of the patient against the medical service in department of radiology and it evaluated the different recognition of radiological technologist and patient, and investigates it's improvement direction. It sent the reply the above the which is a usual result in question result of the most that, the receipt process it was complicated in the portion which is insufficient. 'The receipt process is complication', 'waiting time is long' and ' don't radiation protection for patient and guardian'. Also these a facts was recognizing patients and radiological technologist all. And the effort of the radiological technologist is necessary with the method which reduces a recognition difference. The periodical medical service satisfaction investigates and must endeavor in reform measure preparation

  14. Objectives, Extent and Organization of Radiological and Environmental Protection in Relation to the Nature and Size of Nuclear Facilities

    International Nuclear Information System (INIS)

    Kathren, R.L.

    1979-01-01

    Radiological and environmental protection programs for nuclear facilities have similar goals and objectives, which are basically to protect people and the environment from adverse effects. To be effective, the programs must have organizational independence and a strong commitment from management. In return, the programs should ensure that the facility is operating in full compliance with law and good practice. The scope and elements of radiological environmental protection programs will vary according to facility type and size, with the larger and more complex facilities having a diversity of staff and functions. Examples of good and poor organization charts are given and discussed from the standpoint of program effectiveness along with a discussion of the role of the radiation protection committee. (author)

  15. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  16. Radiological assessment and optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.; Sohier, A.

    1998-01-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised

  17. Federal support of radiological research

    International Nuclear Information System (INIS)

    Hendee, W.R.

    1981-01-01

    Pervading the plans and objective outlined herein for continued and enhanced federal support of research in radiology is a challenge of unparalleled magnitude, for the economic foundation on which this support is based has rarely been more precarious. The new administration in Washington may well be the most fiscally constrained in half a century, and its stated interest in reducing federal expenditures could have disastrous consequences for the scientific research effort in this country, including that in radiology and the radiological sciences. The circumvention of these consequences may well require the dedicated effort of the entire scientific community over the next few months and years, including that part representing radiology and the radiological sciences

  18. Radiology Residents' Performance in Screening Mammography Interpretation

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Lyou, Chae Yeon

    2013-01-01

    To evaluate radiology residents' performance in screening mammography interpretation and to analyze the factors affecting performance. We enrolled 203 residents from 21 institutions and performed mammography interpretation tests. Between the trainee and non-trainee groups, we compared the interpretation score, recall rate, sensitivity, positive predictive value (PPV) and false-positive rate (FPR). We estimated the training effect using the score differences between trainee and non-trainee groups. We analyzed the factors affecting performance between training-effective and non-effective groups. Trainees were superior to non-trainees regarding interpretation score (43.1 vs. 37.1), recall rate (11.0 vs. 15.5%), sensitivity (83.6 vs. 72.0%), PPV (53.0 vs. 32.4%) and FPR (13.5 vs. 25.5). The longer the training period, the better were the interpretation score, recall rate, sensitivity, PPV and FPR (rho = 0.486, -0.375, 0.343, 0.504, -0.446, respectively). The training affected an increase by an average of 6 points; however, 31.6% of institutions showed no effect. A difference was noted in the volume of mammography interpretation during a month (594.0 vs. 476.9) and dedication of breast staff (61.5 vs. 0%) between training-effective and non-effective groups. Trainees showed better performance in mammography interpretation compared to non-trainees. Moreover, performance was correlated with the training period. The factors affecting performance were the volume of mammography interpretation and the dedication of the breast staff.

  19. IRSN. Contract of objectives and performance 2014-2018

    International Nuclear Information System (INIS)

    Le Drian, Jean-Yves; Royal, Segolene; Macron, Emmanuel; Vallaud-Belkacem, Najat; Touraine, Marisol; Fioraso, Genevieve; Repussard, Jacques; Le Guludec, Dominique

    2014-01-01

    After an introduction which presents and comments the IRSN missions, the achievements of the previous contract, IRSN strengths and improvement perspectives, elements of context, and the contract scope and follow-up, this report presents and describes the three strategic areas of improvement: research, expertise and transparency. One or more indicators are defined for each area as well as a quantitative target (number of publications or actions per year). Objectives are then defined regarding security, safety and non proliferation, radiation protection, and crisis situation. Indicators and targets are as well defined for the various identified or defined associated actions or publications. They notably concern expertise missions for safety authorities, the ability to provide a response adapted to safety stakes with a guaranteed integration of lessons learned from the Fukushima accident, the ability to respond to the evolutions of the nuclear fleet (including in terms of dismantling and waste management), the ability to provide expertise and technical support for a better nuclear material safety, for a better protection of radioactive sources against malevolent actions, to contribute to the international struggle against nuclear threats and to the implementation of international treaties (non proliferation treaty, ban of chemical weapons), the implementation of control and assessment actions regarding the exposure to ionizing radiations, the ability to provide responses in the field of the assessment of radiological risks and of the protection against them, the contribution to a better knowledge of the effects of ionizing radiations, the contribution to the development of doctrines and to the improvement of national and international organisations for the management of a radiological or nuclear crisis. A third chapter addresses objectives related to IRSN governance, knowledge management, and financial management. Indicators and targets are also defined. All these

  20. Percutaneous stone removal | van der Ness | SA Journal of Radiology

    African Journals Online (AJOL)

    percutaneous nephrolithotomy (PCNL) at our academic hospital. The primary objective was to determine the percentage successful PCNL procedures performed. Methods. The study included 169 patients (116 males, 53 females; mean age 45 years, range 6 - 75 years) treated with PCNL in our Department of Radiology ...

  1. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  2. Educational course in emergency radiology

    International Nuclear Information System (INIS)

    Velkova, K.; Stoeva, M.; Cvetkova, S.; Hilendarov, A.; Petrova, A.; Stefanov, P.; Simova, E.; Georgieva, V.; Sirakov, N.

    2012-01-01

    Emergency radiology is the part of radiology primarily focused on acute diagnosing conditions in ER patients. This advanced area of radiology improves the quality of care and treatment of patients and of the emergency medicine as a whole. The educational course in Emergency (ER) Radiology is available for medical students in their 8th and 9th semester. The main objective of the ER course is to obtain knowledge about the indications, possibilities and diagnostic value of the contemporary imaging methods in ER cases. Therapeutic methods under imaging control are also covered by the course. The curriculum of the course consists of 6 lectures and 12 practical classes. (authors)

  3. Quality criteria in diagnostic radiology of the skeleton

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1985-01-01

    Conventional diagnostic radiology continues to represent the basic technique in skeleton diagnostics and results in decisive diagnoses in more than 80% of all cases. Compared with other examination methods, it is cheap and relatively easy to perform; however, it makes high demands on the physician's clinical and technical expertise. Compared with computerized tomography, conventional radiography has the advantage of decades of experience and of being cheaper by far. The author thinks the following quality criteria to be important in diagnostic radiology of the skeleton: roentgenological examination of one or several skeleton regions in keeping with the clinical issue concerned, accurate visualization of the object in a typical and reproducible projection, radiation quality matched to the dimension of the object, matched mean optical density, visualization of soft tissue near to bones and joints, and radiation dose in keeping with the clinical issue concerned. (orig./MG) [de

  4. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  5. Exercises for radiological and nuclear emergency response. Planing - performance - evaluation

    International Nuclear Information System (INIS)

    Bayer, A.; Faleschini, J.; Goelling, K.; Stapel, R.; Strobl, C.

    2010-01-01

    The report of the study group emergency response seminar covers the following topics: (A) purpose of exercises and exercise culture: fundamentals and appliances for planning, performance and evaluation; (B) exercises in nuclear facilities; (C) exercises of national authorities and aid organizations on nuclear scenarios; exercises of national authorities and aid organizations on other radiological scenarios; (D) exercises in industrial plants, universities, medical facilities and medical services, and research institutes; (E) transnational exercises, international exercises; (F): exercises on public information.

  6. Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Site

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Meier, Kirsten M.; Snyder, Sandra F.; Fritz, Brad G.; Poston, Theodore M.; Antonio, Ernest J.

    2012-11-12

    Pacific Northwest National Laboratory (PNNL) is in the process of developing a radiological air monitoring program for the PNNL Site that is distinct from that of the nearby Hanford Site. The original DQO (PNNL-19427) considered radiological emissions at the PNNL Site from Physical Sciences Facility (PSF) major emissions units. This first revision considers PNNL Site changes subsequent to the implementation of the original DQO. A team was established to determine how the PNNL Site changes would continue to meet federal regulations and address guidelines developed to monitor air emissions and estimate offsite impacts of radioactive material operations. The result is an updated program to monitor the impact to the public from the PNNL Site. The team used the emission unit operation parameters and local meteorological data as well as information from the PSF Potential-to-Emit documentation and Notices of Construction submitted to the Washington State Department of Health (WDOH). The locations where environmental monitoring stations would most successfully characterize the maximum offsite impacts of PNNL Site emissions from the three PSF buildings with major emission units were determined from these data. Three monitoring station locations were determined during the original revision of this document. This first revision considers expanded Department of Energy operations south of the PNNL Site and relocation of the two offsite, northern monitoring stations to sites near the PNNL Site fenceline. Inclusion of the southern facilities resulted in the proposal for a fourth monitoring station in the southern region. The southern expansion added two minor emission unit facilities and one diffuse emission unit facility. Relocation of the two northern stations was possible due to the use of solar power, rather than the previous limitation of the need for access to AC power, at these more remote locations. Addendum A contains all the changes brought about by the revision 1

  7. Interventional Radiology in Paediatrics.

    Science.gov (United States)

    Chippington, Samantha J; Goodwin, Susie J

    2015-01-01

    As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.

  8. Curricular Guidelines for Dental Auxiliary Radiology.

    Science.gov (United States)

    Journal of Dental Education, 1981

    1981-01-01

    AADS curricular guidelines suggest objectives for these areas of dental auxiliary radiology: physical principles of X-radiation in dentistry, related radiobiological concepts, principles of radiologic health, radiographic technique, x-ray films and intensifying screens, factors contributing to film quality, darkroom, and normal variations in…

  9. Analysis of papers in radiological journals in recent years: a comparison of journal of Korean radiologic society and radiology

    International Nuclear Information System (INIS)

    Kim, Jin Suh; Kim, Jae Kyun; Han, Dong Bok; Lim, Tae Hwan

    1997-01-01

    The purpose of this study was to determine current trends and the mode of future development in the field of medical radiology and to promote research among the nation's radiologists by analyzing the contents of the Journal of the Korean Radiologic Society(JKRS) and Radiology. The number of articles published in JKRS each year between 1990 and 1994 was counted. The research articles in JKRS(n=740) and in Radiology(n=1748) between 1992 and 1994 were categorized according to the objective, type, topic, materials, and radiologic techniques of their contents on the basis of predetermined criteria. Domestic Masters theses(n=126) and doctoral dissertations(n=75) accepted between 1990 and 1994, and domestic materials published in international journals (n=416) between 1986 and 1994 were also categorized using the same criteria. The greatest increase in the number of articles published in JKRS was seen during 1994. The majority of these aimed to retrospectively analyse the findings of diseases while the majority of articles published in Radiology dealt prospectively with the development and/or evaluation of diagnostic methods. More variety of topics and issues was seen in Radiology than in JKRS. The number of articles of domestic materials published in international journals increased from 1986 to 1994, while the number of articles of foreign materials published in Korea was relatively stationary : A significant number of theses and dissertations dealt, mostly prospectively, with studies of pathophysiologic and/or pharmacologic mechanisms using animal models. In order to understand both current trends and the direction and mode of future developments in the field of radiology, and to be able to actively deal with challenges at the forefront of radiologic development, it is essential to review research articles published in radiology-related journals

  10. Relationship Between Dental Hygiene Students' Performance in an Oral Radiology Course and the National Board Dental Hygiene Examination: A Retrospective Study.

    Science.gov (United States)

    Liang, Hui; DeWald, Janice P; Solomon, Eric S

    2018-02-01

    Dental hygiene students' performance in oral radiology courses may give an early indication of their readiness prior to taking the National Board Dental Hygiene Examination (NBDHE). The aim of this study was to determine the relationship between dental hygiene students' performance in an oral radiology lecture course and their performance on the NBDHE. Data were collected for all 117 dental hygiene students at Texas A&M University College of Dentistry from 2006 to 2009 who took the NBDHE during their second year of the program. Their final grades and scores on three written section examinations in an oral radiology course taken in their first year were compared with their overall NBDHE scores and raw scores on the oral radiology and case study sections. Moderate correlations (0.3radiology course, with the strongest correlation with the final grade (r=0.488, pradiology, followed by scores in anatomic sciences; the weakest relationship was with scores in pharmacology. This relationship can help identify students who may need extra support in the oral radiology course and other courses to prepare them to succeed when they take the NBDHE. This study also contributes to understanding of the general relationship between dental hygiene program courses and students' success on the clinical licensing exam and will hopefully encourage other programs to assess their students' performance in this way.

  11. Assessment of the radiological control at the IPEN radioisotope production facility

    International Nuclear Information System (INIS)

    Carneiro, Janete C.G.G.; Sanches, Matias P.; Rodrigues, Demerval L.; Campos, Daniela; Nogueira, Paulo R.; Damato, Sandra R.; Pecequilo, Brigitte R.

    2014-01-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Instituto de Pesquisas Energeticas e Nucleares, IPEN/SP, and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in charcoal and paper filters) at the workplace during radioisotope production were 131 I, 99m Tc and 99 Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m 3 ), the activities concentrations also remained below the maximum permissible values, excepting to 125 I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y -1 , below the ICRP 103 recommended limit of 20 mSv.y -1 for workers. (author)

  12. An honest day's work: pay for performance in a pediatric radiology department

    Energy Technology Data Exchange (ETDEWEB)

    Bisset, George S. [Texas Children' s Hospital, Department of Radiology, Baylor College of Medicine, Houston, TX (United States)

    2017-06-15

    Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology. (orig.)

  13. Radiological controls integrated into design

    Energy Technology Data Exchange (ETDEWEB)

    Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.

  14. Factors that affect the level of detectability of objects of low contrast in diagnostic radiology

    International Nuclear Information System (INIS)

    Zuniga Vargas, F.

    2001-01-01

    The diagnosed imageneologia is every day more used by the medical staff to obtain diagnoses of diverse illnesses. In this branch, the conventional equipments of tubes of X Rays, equipments with fluoroscopic, angiographos, on-line tomographos, ultrasound equipment of magnetic resonance are used. All of them finally produce an image which will be used for the radiologist to evaluate the structures and pathology with in order to give to emit a good and precise diagnosis. From the total of radiation that the man receives annually, the medical irradiations are the main contributors after natural radiations. The applications of the ionized radiations in the medical area have as an objective to provide diagnosis or treatment to the ill patient. To obtain an image of good quality is fundamental, so that the doctor carries out a good diagnosis. The images depend on many physical factors, such as the type of the used equipment, ability of the operator that takes the badge, maintenance of the equipment, badge quality, etc. The images in which the diagnosis is based on are a gathering of gray different tones that draw the anatomy of interest. Therefore, an injury should have different physical characteristics (grosor, density) to stand out from its environment. This notable capacity is known as radiological contrast. Studies which allow the quantification of the radiation levels' effect, the optic badge densities and the observers' physical particularities for the detection of low-contrast objects have not been done in Costa Rica The physician is the one responsible of implementing the quality programs that lead to the gathering of better images. From now on, the asserted diagnosis falls right into the radiologist's experience, who receives the theoretical training and practices of the different diagnosed modalities during his or her residence's years. Besides, the radiologist can collaborate with the improvement of the accuracy of the diagnosis, if he or she recommends the

  15. Radiological performance assessment for the E-Area Vaults Disposal Facility

    International Nuclear Information System (INIS)

    Cook, J.R.

    2000-01-01

    This report is the first revision to ''Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0

  16. Federal Radiological Monitoring and Assessment Center Analytical Response

    International Nuclear Information System (INIS)

    Nielsen, E.C.

    2003-01-01

    The Federal Radiological Monitoring and Assessment Center (FR-MAC) is authorized by the Federal Radiological Emergency Response Plan to coordinate all off-site radiological response assistance to state and local government s, in the event of a major radiological emergency in the United States. The FR-MAC is established by the U.S. Department of Energy, National Nuclear Security Administration, to coordinate all Federal assets involved in conducting a comprehensive program of radiological environmental monitoring, sampling, radioanalysis, quality assurance, and dose assessment. During an emergency response, the initial analytical data is provided by portable field instrumentation. As incident responders scale up their response based on the seriousness of the incident, local analytical assets and mobile laboratories add additional capability and capacity. During the intermediate phase of the response, data quality objectives and measurement quality objectives are more rigorous. These higher objectives will require the use of larger laboratories, with greater capacity and enhanced capabilities. These labs may be geographically distant FR-om the incident, which will increase sample management challenges. This paper addresses emergency radioanalytical capability and capacity and its utilization during FR-MAC operations

  17. Diagnosis of radiological security of installations

    International Nuclear Information System (INIS)

    Herrera V, L.

    1991-01-01

    The objective of this work is to discuss the diagnosis of the radiological safety of nuclear or radioactive facilities. It was concluded that the one diagnoses like discipline of the radiological safety is susceptible of being represented, taught and programmable in computer and useful systems as preventive tool and of inspection

  18. Emergency radiology curriculum at Medical University - Plovdiv

    International Nuclear Information System (INIS)

    Velkova, K.; Hilendarov, A.; Cvetkova, S.; Stoeva, M.; Petrova, A.; Stefanov, P.; Simova, E.; Georgieva, V.; Sirakov, N.

    2012-01-01

    Full text: Introduction: Recent advances in contemporary radiology turn it into one of the major sources for patient information with improved emergency techniques. Emergency Radiology (EP) focuses on acute diagnosing conditions in ER patients. Objectives: The main objective of this paper is to present the ER curriculum at Medical Imaging Department, Medical University - Plovdiv, aiming to deliver knowledge about the indications, possibilities and diagnostic value of the contemporary imaging methods in ER cases. Material and methods: The curriculum covers various aspects of ER Radiology - diagnostic imaging methods, contrast enhanced examinations, imaging topography, traumatic and acute conditions, physical and technical aspects. It includes 6 lectures and 12 practical classes. Results and discussion: The educational course in Emergency Radiology is available for medical students in their 8-th and 9-th semester. Therapeutic methods under imaging control are also covered by the course. Conclusion: Being one of the most advanced areas of radiology, ER improves the quality of care and treatment of patients and of the emergency medicine as a whole

  19. Welding. Performance Objectives. Intermediate Course.

    Science.gov (United States)

    Vincent, Kenneth

    Several intermediate performance objectives and corresponding criterion measures are listed for each of nine terminal objectives for an intermediate welding course. The materials were developed for a 36-week (3 hours daily) course designed to prepare the student for employment in the field of welding. Electric welding and specialized (TIG & MIG)…

  20. Welding. Performance Objectives. Basic Course.

    Science.gov (United States)

    Vincent, Kenneth

    Several intermediate performance objectives and corresponding criterion measures are listed for each of eight terminal objectives for a basic welding course. The materials were developed for a 36-week (2 hours daily) course developed to teach the fundamentals of welding shop work, to become familiar with the operation of the welding shop…

  1. Federal Radiological Monitoring and Assessment Center. The analytical response

    International Nuclear Information System (INIS)

    Nielsen, E.C.

    2005-01-01

    The Federal Radiological Monitoring and Assessment Center (FRMAC) is authorized by the Federal Radiological Emergency Response Plan to coordinate all off-site radiological response assistance to state and local governments, in the event of a major radiological emergency in the United States. The FRMAC is established by the U.S. Department of Energy, National Nuclear Security Administration, to coordinate all Federal assets involved in conducting a comprehensive program of radiological environmental monitoring, sampling, radioanalysis, quality assurance, and dose assessment. During an emergency response, the initial analytical data is provided by portable field instrumentation. As incident responders scale up their response based on the seriousness of the incident, local analytical assets and mobile laboratories add additional capability and capacity. During the intermediate phase of the response, data quality objectives and measurement quality objectives are more rigorous. These higher objectives will require the use of larger laboratories, with greater capacity and enhanced capabilities. These labs may be geographically distant from the incident, which will increase sample management challenges. Emergency radioanalytical capability and capacity and its utilization during FRMAC operations are discussed. (author)

  2. Medical radiology terminology

    International Nuclear Information System (INIS)

    1986-01-01

    Standardization achievements in the field of radiology induced the IEC to compile the terminology used in its safety and application standards and present it in publication 788 (1984 issue), entitled 'Medical radiology terminology'. The objective pursued is to foster the use of standard terminology in the radiology standards. The value of publication 788 lies in the fact that it presents definitions of terms used in the French and English versions of IEC standards in the field of radiology, and thus facilitates adequate translation of these terms into other languages. In the glossary in hand, German-language definitions have been adopted from the DIN standards in cases where the French or English versions of definitions are identical with the German wording or meaning. The numbers of DIN standards or sections are then given without brackets, ahead of the text of the definition. In cases where correspondance of the various texts is not so good, or reference should be made to a term in a DIN standard, the numbers are given in brackets. (orig./HP) [de

  3. Trends in radiology in Finland between 1995 and 2000

    International Nuclear Information System (INIS)

    Hakanen, Arvi; Jaervinen, Hannu; Soimakallio, Seppo

    2003-01-01

    The aim of this study was to demonstrate the applicability of a joint nomenclature, i.e., the examination coding system used in Finland, for making a nationwide summary of the radiological examinations and interventional procedures. Another objective was to find trends in radiological practices in Finland between 1995 and 2000 by comparing the nationwide summaries made by Radiation and Nuclear Safety Authority (STUK). An inquiry for the numbers of radiological examinations performed in 2000 was sent to 473 medical radiation users, i.e., safety license holders obtained from the registry maintained by STUK. In 2000, the proportions of plain radiography, contrast-enhanced radiography, angiography, computed tomography and radiological interventional procedures were approximately 91.1, 1.4, 0.9, 5.0, and 1.5%, respectively (distribution of medical examinations). Between 1995 and 2000, the number of medical X-ray examinations showed a slight decrease from ca. 4.2 million to ca. 4.1 million. During the investigated five years period the frequency of contrast enhanced radiography diminished ca. 50% while the frequency of computed tomography increased ca. 20%. The reported number of ultrasonographic examinations showed a slight increase to approximately 0.5 million, whereas the reported number of MRI examinations increased approximately twofold to approximately 0.1 million. The observed trends in radiological practices are useful in attempts to optimize the resources of STUK in the field of radiological protection. (orig.)

  4. Idaho National Engineering Laboratory Radiological Control Performance Indicator Report. Fourth quarter -- year-end report, Calendar year 1995

    International Nuclear Information System (INIS)

    Reavis, R.

    1996-03-01

    The INEL Radiological Control Performance Indicator Report is comprised of a description of the indicator and the criteria used for measurement. Indicators evaluated in this report include: collective radiation dose; average worker radiation dose; maximum radiation dose to a worker; maximum neutron dose to a worker; number of skin contaminations; number of clothing contaminations; airborne events; total radiological intakes; contamination areas; high contamination area; airborne radioactivity area; and radioactive spills

  5. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  6. Performance objectives for the Hanford Immobilized Low-Activity Waste (ILAW) performance assessment

    International Nuclear Information System (INIS)

    MANN, F.M.

    1999-01-01

    Performance objectives for the disposal of low activity waste from Hanford Waste Tanks have been developed. These objectives have been based on DOE requirements, programmatic requirements, and public involvement. The DOE requirements include regulations that direct the performance assessment and are cited within the Radioactive Waste Management Order (DOE Order 435.1). Performance objectives for other DOE complex performance assessments have been included

  7. Assessment of the radiological control at the IPEN radioisotope production facility

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J.C.G.G.; Sanches, M.P.; Rodrigues, D.L.; Campos, D.; Nogueira, P.R.; Damatto, S.R.; Pecequilo, B.R.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Nuclear and Energy Research Institute, IPEN/SP, Brazil and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in activated carbon cartridges and filter paper) at the workplace during radioisotope production were {sup 131}I, {sup 99m}Tc and {sup 99}Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m{sup 3} ), the activities concentrations also remained below the maximum admissible values, excepting to {sup 125}I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y{sup -1} , below the ICRP 103 recommended limit of 20 mSv.y{sup -1} for workers. (author)

  8. Risks arising during manipulation with radiologically specific products of biotechnical production

    International Nuclear Information System (INIS)

    Mitrovic, R.; Vukovic, D.; Vicentijevic, M.; Kljajic, R.

    1998-01-01

    Objective of this study was to review the risk of exposure to radiocaesium (134+137Cs), which biologically presents the most toxic radionuclide, of people engaged in the process of supervision, transport and storage of the radiologically specific products, like concentrated protein feedstuff (fish meal, powdered milk), wool, cow hide and chamois. The discussion is based on the results of a radiological-hygienic analysis of these products in the context of veterinary-sanitary control, performed in the authorized referent Laboratory for Radiation Hygiene (LABRAH) at the Scientific Institute for Veterinary Medicine of Serbia in Belgrade (Yugoslavia)

  9. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    OpenAIRE

    Zahra Jomehzadeh; Ali Jomehzadeh; Mohammad Bagher Tavakoli

    2016-01-01

    Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based ...

  10. Radiation protection and quality assurance in dental radiology: II. Panoramic radiology

    International Nuclear Information System (INIS)

    Jodar-Porlan, S.; Alcaraz, M.; Martinez-Beneyto, Y.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.

    2001-01-01

    This paper studies 278 official reports on quality assurance in dental radiology in the context of the first revision of these dental clinics, as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an panoramic radiology apparatus, making a special reference to the brands they have available, as well as their physical features (kV, mA, filtration) and the deviations detected in their operation. Some of their features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionising radiation used in order to obtain the same tooth radiological image is presented. This paper shows, in a quantitative way, the characteristic features of panoramic radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)

  11. Objectives and actions of Public Health Authorities in external radiological emergency

    International Nuclear Information System (INIS)

    Herrera V, L.; Aguilar P, M.C.

    1991-01-01

    Here are discussed actions and objectives that the public health authorities could think about uncontrolled liberation of radioactive materials. The approaches on the more convenient actions to continue are established upon assimilating the Chernobyl experience. We will enumerate problems that, they could arise with the foregone actions in order to diminish the population detriment. In the face of the uncontrolled liberation of radioactive material in the Nuclear power plant of Laguna Verde, Veracruz, classified like external radiological emergency, the objective of these serious authorities reduce the deleterious effect to the health of the inhabitants around the CNLV, due to the radioactive material liberated to the atmosphere. In consequence, it is necessary carry out actions of protection for the population affected directly by the external irradiation, for the contamination deposited on inhabited areas, cultivation zones, shepherding, manufacturing and farms. The early actions or immediate are in order to limit deterministic damages to the population and give attendance to people with radio lesions. And the intermediate or they of recuperation are in order to maintain for under an acceptable value the risk to the population due to radiation stochastic effects. In the recuperation phase the plan of water and foods control should consider: foods destined to the self consume in the affected region for the liberation and foods processed for the sale or exportation. We will discuss the stage in a mediate phase after the evacuation of the population. The general tasks could be: 1. Actions in order to impede the contamination propagation. 2. Sampling of waters and foods, contamination situation and its quantification. And acceptance quality in elaborated foods. 3. Safeguard of the material and polluted areas. 4. Election of the actions to continue in function of the reference levels and the comparison of the risk of several alternatives. (Author)

  12. Performance Objective for Tank Farm Closure Risk Assessments

    International Nuclear Information System (INIS)

    MANN, F.M.; KNEPP, A.J.; BADDEN, J.

    2003-01-01

    To be meaningful, results from a numeric risk assessment of the consequences of an action must be compared against the standards for such an action. That is, before one disposes of waste or closes a facility with waste, one must show that the disposal or closure action protects the public health and safety and the environment. These standards are called performance objectives. Regulations requiring performing performance assessments, (whether federal ones like the Department of Energy [DOE] Order 435.1, Radioactive Waste Management and its implementing guides or Washington State ones like the regulations implementing the Washington Administrative Code [WAC] 173-340 ''Model Toxics Control Act - Cleanup''), usually require that the determination of performance objectives be one of the first steps performed. These performance objectives not only set comparison level for the numeric results, but also define the media, pathways, exposure scenarios (receptors), spatial locations, and times that the performance assessment must consider. Thus, a performance objective consists of a compliance level, place(s) of compliance, and time(s) of compliance. Performance objectives are not the levels that a regulatory agency will enforce in a permit or authorization. Those levels, often called enforcement levels, will be set in the permit or authorization. Rather, performance objectives are those levels against which the results of the numeric simulation will be compared to judge the success of the proposed cleanup or disposal actions. Additional comparison levels may be requested for information purposes, but are not officially part of the decision on the adequacy of the proposed action. To emphasize that the performance objectives discussed in this document are not regulatory performance objectives, the three components of the performance objective will be renamed in this document as assessment standard, point(s) of assessment, and time(s) of assessment. However, whenever

  13. Efficient radiologic reading environment by using an open-source macro program as connection software.

    Science.gov (United States)

    Lee, Young Han

    2012-01-01

    The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Efficient radiologic reading environment by using an open-source macro program as connection software

    International Nuclear Information System (INIS)

    Lee, Young Han

    2012-01-01

    Purpose: The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. Materials and methods: The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. Results: The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. Conclusion: A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software.

  15. Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Richland Campus

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Sandra F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Moleta, Donna Grace L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Meier, Kirsten M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barnett, John M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-12-31

    This is the second revision of the DQO Supporting Radiological Air Emissions Monitoring for the Pacific Northwest National Laboratory Richland Campus. In January 2017, the PNNL Richland Campus expanded to the north by 0.35 km2 (85.6 acres). Under the requirements of Washington State Department of Health Radioactive Air Emissions License (RAEL)-005, the PNNL Campus operates and maintains a radiological air monitoring program. This revision documents and evaluates the newly acquired acreage while also removing recreational land at the southwest, and also re-examines all active radioactive emission units on the PNNL Campus. No buildings are located on this new Campus land, which was transferred from the U.S. DOE Hanford Site. Additionally, this revision includes information regarding the background monitoring station PNL-5 in Benton City, Washington, which became active in October 2016. The key purpose of this revision is to determine the adequacy of the existing environmental surveillance stations to monitor radiological air emissions in light of this northern boundary change.

  16. Role of radiology in occupational medicine

    International Nuclear Information System (INIS)

    Vehmas, T.

    2004-01-01

    This review discusses the contribution of radiology to occupational medicine as well as work-related problems in radiology dept.s. Research issues are emphasized. Radiology has been used especially when diagnosing occupational respiratory and locomotive system problems and solvent-induced encephalo- and hepatopathy. The aim of research in these areas is usually to characterize occupational diseases and to identify physico-chemical hazards in the work place by comparing between groups of workers and non-exposed controls. Radiological imaging allows an objective characterization of the disease, and it may clarify the pathogenesis of the process and provide a useful epidemiological tool. Advanced statistical methods are often needed to adjust analyses for confounding variables. As the diagnostic requirements are increasing, more sensitive and sophisticated radiological methods, such as high-resolution computed tomography, magnetic resonance imaging and magnetic resonance spectroscopy, may be required for the early recognition of occupational health risks. This necessitates good cooperation between occupational health units and well-equipped imaging dept.s. Considering occupational problems in radiology departments, the increasing use of digital radiology requires ergonomic measures to control and prevent locomotive problems caused by work with computers. Radiation protection measures are still worth concern, especially in interventional radiology

  17. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  18. Radiology education: a radiology curriculum for all medical students?

    Science.gov (United States)

    Zwaan, Laura; Kok, Ellen M; van der Gijp, Anouk

    2017-09-26

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some people argue that non-radiologists should not diagnose medical images at all, and that medical school should focus on teaching ordering skills instead of image interpretation skills. We agree that teaching ordering skills is crucial as most physicians will need to order medical images in their professional life. However, we argue that the availability of medical images is so ubiquitous that it is important that non-radiologists are also trained in the basics of medical image interpretation and, additionally in recognizing when radiological consultancy should be sought. In acute situations, basic image interpretations skills can be life-saving. We plead for a radiology curriculum for all medical students. This should include the interpretation of common abnormalities on chest and skeletal radiographs and a basic distinction of normal from abnormal images. Furthermore, substantial attention should be given to the correct ordering of radiological images. Finally, it is critical that students are trained in deciding when to consult a radiologist.

  19. Sequestration Coating Performance Requirements for Mitigation of Contamination from a Radiological Dispersion Device

    International Nuclear Information System (INIS)

    Drake, J.

    2009-01-01

    Immediate action would be necessary to minimize the effects of a radiological 'dirty bomb' detonation in a major city. After a dirty bomb has been detonated, vehicular and pedestrian traffic, as well as weather effects, would increase the spread of loose contamination, making control and recovery more difficult and costly. While contaminant migration and chemical binding into surface materials can be relatively rapid, the immediate treatment of surfaces with large quantities of an appropriate compound could alleviate much of the difficulty in decontamination. The EPA's National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, is currently developing performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination. These performance standards are being promulgated via an ASTM Standard Specification to be published by ASTM International. Test methods will be developed to determine if candidate coatings meet the performance requirements stipulated in the ASTM performance standard. These test methods will be adapted from existing standard methods, or will be devised through laboratory research. The final set of test methods will be codified in an ASTM or other standard test method. The principal market for products described in the ASTM performance standard would be federal, state and local government emergency responders and response planners, decontamination service providers and those whose interests include protection and recovery of real estate potentially at risk from radiological terrorism. (authors)

  20. Machine learning and radiology.

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  1. Guidelines for a radiology department

    International Nuclear Information System (INIS)

    1981-05-01

    This manual presents guidelines for hospitals on a radiology quality assurance and dose measurement audit program and a system of planned actions that monitor and record the performance and effectiveness of the radiological service

  2. Radiological characterisation of contaminated concretes from the object 44/20 of NPP A1

    International Nuclear Information System (INIS)

    Slavik, O.; Listjak, M.; Pely, I.; Soos, F.

    2005-01-01

    Results of radiological characterisation of contaminated concretes from object 44/20 of the NPP A-1 Jaslovske Bohunice are summarized in this work. These works were carried out in VUJE in the laboratory of environmental dosimetry in 2004 and partially in 2005. The main results of radiological characterisation can be summarised as follow: (1) Contamination of concretes is in all cases surficial, it reaches up to 5-10 mm, the dominant contaminant is 137 Cs; (2) The spawn concrete is mostly contaminated only from one side (one being adjacent to the ceiling concrete), crucial part of them is even on this side contaminated in very low level complying with free release level; (3) The ceiling concrete blocks are contaminated mostly on one side, only (the inner side of shafts), their decontamination will require removing of about 5 mm thick surface layer. (4) The floor concrete is covered by heavily contaminated dust 137 CS, 100-500 Bq/g), originating from sorting of the wet RAW .Its decontamination will require removing of 10 mm thick surface concrete layer; (5) The core samples taken from the whole depth profile of the ceiling concrete show also only surface contamination, samples prepared from the deeper layers have not demonstrated any contamination in these layers. Control measurements of deeper concrete layers, however, went on with negative results also in year 2005; (6) The relative content for 90 Sr in these concretes is in average about 8%, for 241 Am determined by gamma-spectrometry is 0.4% and for 239 , 240 Pu determined radiochemically is 0.33% in comparison with the content of 137 Cs. (authors)

  3. Comparative Study on Radiological Impact Due To Direct Exposure to a Radiological Dispersal Device Using A Sealed Radiation Source

    International Nuclear Information System (INIS)

    Margeanu, C.A.

    2011-01-01

    Nowadays, one of the most serious terrorist threats implies radiological dispersal devices (RDDs), the so-called dirty bombs, that combine a conventional explosive surrounded by an inflammatory material (like thermit) with radioactive material. The paper objective is to evaluate the radiological impact due to direct exposure to a RDD using a sealed radiation source (used for medical and industrial applications) as radioactive material. The simulations were performed for 60Co, 137Cs and 192Ir radiation sources. In order to model the contamination potential level and radiation exposure due to radioactive material spreading from RDD, Lawrence Livermore National Laboratory's HOTSPOT 2.07 computer code was used. The worst case scenario has been considered, calculations being performed for two radioactive material dispersion models, namely General radioactive Plume and General Explosion. Following parameters evolution with distance from the radiation source was investigated: total effective dose equivalent, time-integrated air concentration, ground surface deposition and ground shine dose rates. Comparisons between considered radiation sources and radioactive material dispersion models have been performed. The most drastic effects on population and the environment characterize 60Co sealed radiation source use in RDD.

  4. "Flipping" the introductory clerkship in radiology: impact on medical student performance and perceptions.

    Science.gov (United States)

    Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J

    2015-06-01

    Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of Radiology Teachers' Performance and Identification of the "Best Teachers" in a Residency Program: Mixed Methodology and Pilot Study of the MEDUC-RX32 Questionnaire.

    Science.gov (United States)

    Huete, Álvaro; Julio, Rodrigo; Rojas, Viviana; Herrera, Cristián; Padilla, Oslando; Solís, Nancy; Pizarro, Margarita; Etcheberry, Lorena; Sarfatis, Alberto; Pérez, Gonzalo; Díaz, Luis A; Delfino, Alejandro; Muñoz, Estrella; Rivera, Horacio; Parra, Dimitri A; Bitran, Marcela; Riquelme, Arnoldo

    2016-07-01

    Radiology teachers are well trained in their specialty; however, when working in academic institutions, faculty development and promotion through the education pathway tends to be based on their teaching knowledge and skills. The aim of this study is to assess psychometric properties of the Medicina Universidad Católica-Radiology 32 items (MEDUC-RX32), an instrument designed to evaluate the performance of postgraduate radiology teachers and to identify the best teachers. Mixed methodology was used, including qualitative and quantitative phases. The psychometric properties of the MEDUC-RX32 survey were performed by factor analysis (validity), Cronbach alpha coefficient, and G coefficient (reliability). The residents assessed their teachers and simultaneously voted for the "best teacher," which was used as a gold standard for the receiver operating characteristic curves construction comparing their votes with the global score. A total of 28 residents answered 164 surveys. The global score was 6.23 ± 0.8 (scale from 1 to 7). The factor analysis showed six domains of the resident's perception: (1) tutorial teaching, feedback, and independent learning; (2) communication and teamwork; (3) learning objectives; (4) respectful behavior; (5) radiological report; and (6) teaching and care support. The tutor's strengths were related with respectful behavior and teamwork. The instrument is highly reliable with a Cronbach alpha of 0.937 and a G coefficient of 0.831 (with a minimum of 8 residents). The MEDUC-RX32 instrument has a sensitivity of 91.7% and specificity of 83.3% to identify tutors as best teachers with at least one vote with an area under the receiver operating characteristic curve of 0.931 with a cutoff of 5.94. The MEDC-RX32 instrument is a multidimensional, valid, and highly reliable method to evaluate radiology teachers, identifying teachers with excellence in tutorial teaching in a postgraduate radiology program. Copyright © 2016 The Association of

  6. Perception of radiological technicians on radiation protection

    International Nuclear Information System (INIS)

    Viana, E.; Borges, L.M.; Camozzato, T.S.C.

    2017-01-01

    The objective of this study was to know the professionals' perception of radiological techniques about radiation protection in the work process in Nuclear Medicine. The research was carried out with nine professionals of the radiological techniques of two private institutions located in the South of Brazil. An interview was applied through recording and transcription. The analysis of the data took place through a thematic analysis. The professionals' perception of radiological techniques regarding the radiological protection in the work process is evidenced when professionals mention the basic rules of radiation protection: time, shielding and distance as attitudes used to minimize the exposure to ionizing radiation. However, it was verified the fragility in the knowledge about the norms and legislation of the radiological protection

  7. Focused process improvement events: sustainability of impact on process and performance in an academic radiology department.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Lawson, Kirk; Ally, Rosina; Chen, David; Donno, Frank; Rittberg, Steven; Rodriguez, Joan; Recht, Michael P

    2015-01-01

    To evaluate sustainability of impact of rapid, focused process improvement (PI) events on process and performance within an academic radiology department. Our department conducted PI during 2011 and 2012 in CT, MRI, ultrasound, breast imaging, and research billing. PI entailed participation by all stakeholders, facilitation by the department chair, collection of baseline data, meetings during several weeks, definition of performance metrics, creation of an improvement plan, and prompt implementation. We explore common themes among PI events regarding initial impact and durability of changes. We also assess performance in each area pre-PI, immediately post-PI, and at the time of the current study. All PI events achieved an immediate improvement in performance metrics, often entailing both examination volumes and on-time performance. IT-based solutions, process standardization, and redefinition of staff responsibilities were often central in these changes, and participants consistently expressed improved internal leadership and problem-solving ability. Major environmental changes commonly occurred after PI, including a natural disaster with equipment loss, a change in location or services offered, and new enterprise-wide electronic medical record system incorporating new billing and radiology informatics systems, requiring flexibility in the PI implementation plan. Only one PI team conducted regular post-PI follow-up meetings. Sustained improvement was frequently, but not universally, observed: in the long-term following initial PI, measures of examination volume showed continued progressive improvements, whereas measures of operational efficiency remained stable or occasionally declined. Focused PI is generally effective in achieving performance improvement, although a changing environment influences the sustainability of impact. Thus, continued process evaluation and ongoing workflow modifications are warranted. Copyright © 2015 American College of Radiology

  8. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  9. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  10. Improving efficiency in the radiology department

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Alexander J.; Perry, Laurie A. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2017-06-15

    The modern radiology department is built around the flow of information. Ordering providers request imaging studies to be performed, technologists complete the work required to perform the imaging studies, and radiologists interpret and report on the imaging findings. As each of these steps is performed, data flow between multiple information systems, most notably the radiology information system (RIS), the picture archiving and communication system (PACS) and the voice dictation system. Even though data flow relatively seamlessly, the majority of our systems and processes are inefficient. The purpose of this article is to describe the radiology value stream and describe how radiology informaticists in one department have worked to improve the efficiency of the value stream at each step. Through these examples, we identify and describe several themes that we believe have been crucial to our success. (orig.)

  11. Systematic Layout Planning of a Radiology Reporting Area to Optimize Radiologists' Performance.

    Science.gov (United States)

    Benitez, Guilherme Brittes; Fogliatto, Flavio Sanson; Cardoso, Ricardo Bertoglio; Torres, Felipe Soares; Faccin, Carlo Sasso; Dora, José Miguel

    2018-04-01

    Optimizing radiologists' performance is a major priority for managers of health services/systems, since the radiologists' reporting activity imposes a severe constraint on radiology productivity. Despite that, methods to optimize radiologists' reporting workplace layout are scarce in the literature. This study was performed in the Radiology Division (RD) of an 850-bed University-based general hospital. The analysis of the reporting workplace layout was carried out using the systematic layout planning (SLP) method, in association with cluster analysis as a complementary tool in early stages of SLP. Radiologists, architects, and hospital managers were the stakeholders consulted for the completion of different stages of the layout planning process. A step-by-step description of the proposed methodology to plan an RD reporting layout is presented. Clusters of radiologists were defined using types of exams reported and their frequency of occurrence as clustering variables. Sectors with high degree of interaction were placed in proximity in the new RD layout, with separation of noisy and quiet areas. Four reporting cells were positioned in the quiet area, grouping radiologists by subspecialty, as follows: cluster 1-abdomen; cluster 2-musculoskeletal; cluster 3-neurological, vascular and head & neck; cluster 4-thoracic and cardiac. The creation of reporting cells has the potential to limit unplanned interruptions and enhance the exchange of knowledge and information within cells, joining radiologists with the same expertise. That should lead to improvements in productivity, allowing managers to more easily monitor radiologists' performance.

  12. Site-Specific Analyses for Demonstrating Compliance with 10 CFR 61 Performance Objectives - 12179

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, C.J.; Esh, D.W.; Yadav, P.; Carrera, A.G. [U.S. Nuclear Regulatory Commission, 11545 Rockville Pike, Rockville, MD 20852 (United States)

    2012-07-01

    The U.S. Nuclear Regulatory Commission (NRC) is proposing to amend its regulations at 10 CFR Part 61 to require low-level radioactive waste disposal facilities to conduct site-specific analyses to demonstrate compliance with the performance objectives in Subpart C. The amendments would require licensees to conduct site-specific analyses for protection of the public and inadvertent intruders as well as analyses for long-lived waste. The amendments would ensure protection of public health and safety, while providing flexibility to demonstrate compliance with the performance objectives, for current and potential future waste streams. NRC staff intends to submit proposed rule language and associated regulatory basis to the Commission for its approval in early 2012. The NRC staff also intends to develop associated guidance to accompany any proposed amendments. The guidance is intended to supplement existing low-level radioactive waste guidance on issues pertinent to conducting site-specific analyses to demonstrate compliance with the performance objectives. The guidance will facilitate implementation of the proposed amendments by licensees and assist competent regulatory authorities in reviewing the site-specific analyses. Specifically, the guidance provides staff recommendations on general considerations for the site-specific analyses, modeling issues for assessments to demonstrate compliance with the performance objectives including the performance assessment, intruder assessment, stability assessment, and analyses for long-lived waste. This paper describes the technical basis for changes to the rule language and the proposed guidance associated with implementation of the rule language. The NRC staff, per Commission direction, intends to propose amendments to 10 CFR Part 61 to require licensees to conduct site-specific analyses to demonstrate compliance with performance objectives for the protection of public health and the environment. The amendments would require a

  13. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  14. Radiological objectives and severe accident mitigation strategy for the generation II PWRs in France in the framework of PLE

    International Nuclear Information System (INIS)

    Cenerino, G.; Dubreuil, M.; Raimond, E.; Pichereau, F.

    2012-01-01

    In France, EDF is involved in the construction of a first generation III (Gen III) reactor (European Pressurized Reactor - EPR) on Flamanville site next to two PWRs. Plant Life Extension (PLE) of reactors will consequently lead to simultaneous operation of Gen III and Gen II reactors during a long period of time. As a consequence, EDF was requested by the French Nuclear Safety Authority to prepare a PWR life management program including, in addition to an ageing management of Systems, Structures and Components, a consequent reactor safety enhancement program. The objective was stated to EDF by the French Nuclear Safety Authority: 'the safety objectives of the Gen III reactors should be used as a reference for all studies undertaken in the frame of PLE'. One part of the EDF program deals with additional arrangements able to reduce more drastically the consequences of any accident. The relevance, according to IRSN, of the EDF radiological objectives for Design Basis Accidents, of the new EDF objectives for Severe Accidents (SA) and of the EDF potential modifications for SA mitigation are presented. (author)

  15. The Future of Radiology

    Directory of Open Access Journals (Sweden)

    Alexander R. Margulis

    2011-07-01

    Full Text Available It has been my good fortune to live and practice radiology during a long period of momentous change – to see the transformation of the discipline from a supportive service into a mainstream, essential branch of clinical medicine. I remember wearing red goggles to adapt my vision before performing fluoroscopy; observing the horrible, now thankfully obsolete, practice of ventriculography, which was considered advanced neuroradiology; and performing other, now rarely prescribed procedures, such as double-contrast barium enemas and intravenous pyelography. Witnessing the beginnings of interventional radiology, I suggested its name in an editorial. I also had the good fortune to see the introduction of computed tomography (CT and a technology first known as nuclear magnetic resonance imaging. Together with fellow members of a committee of the American College of Radiology and editors of prestigious radiological journals, I took part in changing the name of the latter modality to MRI, freeing it from threatening implications. Looking back on these experiences, one lesson stands out above all: Innovation and transformation never cease. Looking forward, it is clear that radiology, along with the rest of medicine, is now undergoing further momentous changes that will affect the future of all those already practicing as well as those yet to start their careers.

  16. The radiology in the solitary bone lesions

    International Nuclear Information System (INIS)

    Veloso, G.A.; Cardoso, V.M.

    1985-01-01

    Three methods of radiologic analysis of the solitary bone lesions are reviewed. 1. Radiological analysis of the lesions with the objective to suppose the histologic type; 2. To appreciate the velocity of growth and aggressiveness of the lesions. 3. To appreciate the biological behaviour of the bone lesions, making the diagnosis necessary for the treatment. (M.A.C.) [pt

  17. The Symbiose project: an integrated framework for performing environmental radiological risk assessment

    International Nuclear Information System (INIS)

    Gonze, M.A.; Mourlon, C.; Garcia-Sanchez, L.; Beaugelin, K.; Chen, T.; Le Dizes, S.

    2004-01-01

    Human health and ecological risk assessments usually require the integration of a wide range of environmental data and modelling approaches, with a varying level of detail dependent on the management objectives, the complexity of the site and the level of ignorance about the pollutant behaviour/toxicity. Like most scientists and assessors did it recently, we recognized the need for developing comprehensive, integrated and flexible approaches to risk assessment. To meet these needs, IRSN launched the Symbiose project (2002-2006) which aims first, at designing a framework for integrating and managing data, methods and knowledge of some relevance in radiological risk to humans/biota assessment studies, and second, at implementing this framework in an information management, modelling and calculation platform. Feasibility developments (currently completed) led to the specification of a fully integrated, object-oriented and hierarchical approach for describing the fate, transport and effect of radionuclides in spatially-distributed environmental systems. This innovative approach has then been implemented in a platform prototype, main components of which are a user-friendly and modular simulation environment (e.g. using GoldSim toolbox), and a hierarchical object-oriented biosphere database. Both conceptual and technical developments will be presented here. (author)

  18. Non-nuclear radiological emergencies. Special plan for radiological risk of the Valencian Community

    International Nuclear Information System (INIS)

    Rodríguez Rodrigo, I.; Piles Alepuz, I.; Peiró Juan, J.; Calvet Rodríguez, D.

    2015-01-01

    After the publication of the Radiological Hazard Basic Directive, Generalitat (the regional government in Valencian Community) initiated the edition of the pertinent Special Plan, with the objective to assemble the response of all the Security and Emergency Agencies, including the Armed Forces, in a radiological emergency affecting the territory of the Valencian Community, under a single hierarchy command. Being approved and homologated the Radiological Hazard Special Plan, Generalitat has undertaken the implementation process planned to finish in June 2015. Following the same process as other Plans, implementation is organized in a first informative stage, followed of a formative and training stage, and finishing with an activation exercise of the Plan. At the end of the process, is expected that every Agency will know their functions, the structure and organization in which the intervention takes place, the resources needed, and adapt their protocols to the Plan requirements. From the beginning, it has been essential working together with the Nuclear Safety Council, as is established in the agreement signed in order to collaborate in Planning, Preparedness and Response in Radiological Emergencies. [es

  19. Quality assurance in diagnostic radiology

    International Nuclear Information System (INIS)

    1982-01-01

    The present guide endeavours to provide an outline of the type of quality assurance programme to be recommended for (1) routine implementation by those performing radiodiagnostic procedures (medical radiology technicians, medical physicists, and radiologists), (2) for application by the responsible national authorities, and (3) for use by international bodies such as the International Society of Radiology (ISR), the International Commission on Radiological Protection (ICRP), and the International Commission on Radiation Units and Measurements (ICRU)

  20. The economics of interventional radiology

    International Nuclear Information System (INIS)

    Price, G.W.

    1988-01-01

    At a time when policy makers and regulators are scheming to reduce the costs and utilization of medical services, interventional radiology is poised for growth. Part of this potential for growth is based on wider acceptance of the procedures performed by interventional radiologists. A second factor in the growth potential is the relative value in cost of these procedures compared with alternative therapies. The author presents a discussion of the differences in the relative value of these procedures when performed by physicians of different specialties. This paper reviews the status of the economic climate in the health care delivery system and the role and potential growth of interventional radiology. This includes a review of current data on the utilization of interventional radiology procedures in the Medicare program. This overview includes a discussion of the initiatives of the federal government which directly impact interventional radiology

  1. Radiological aspects of childhood pulmonary blastoma

    International Nuclear Information System (INIS)

    Gonzalez, J.; Lopez, A.M.; Martinez, F.; Pineda, G.; Martinez, A.

    1996-01-01

    The objective is to present different clinical and radiological aspects of an uncommon primary lung tumor. Patients, Between 1974 and 1994, this rare pathology, which has seldom been reported in the literature, was diagnosed in four patients in our hospital. The clinical, radiological and pathological findings are presented. the prognosis is poor. Two of the four patients is disease-free-and the fourth is undergoing cytoreduction. (Author) 8 refs

  2. Bibliometric Analysis of Manuscript Characteristics That Influence Citations: A Comparison of Six Major Radiology Journals.

    Science.gov (United States)

    Shekhani, Haris Naseem; Shariff, Shoaib; Bhulani, Nizar; Khosa, Faisal; Hanna, Tarek Noel

    2017-12-01

    The objective of our study was to investigate radiology manuscript characteristics that influence citation rate, capturing features of manuscript construction that are discrete from study design. Consecutive articles published from January 2004 to June 2004 were collected from the six major radiology journals with the highest impact factors: Radiology (impact factor, 5.076), Investigative Radiology (2.320), American Journal of Neuroradiology (AJNR) (2.384), RadioGraphics (2.494), European Radiology (2.364), and American Journal of Roentgenology (2.406). The citation count for these articles was retrieved from the Web of Science, and 29 article characteristics were tabulated manually. A point-biserial correlation, Spearman rank-order correlation, and multiple regression model were performed to predict citation number from the collected variables. A total of 703 articles-211 published in Radiology, 48 in Investigative Radiology, 106 in AJNR, 52 in RadioGraphics, 129 in European Radiology, and 157 in AJR-were evaluated. Punctuation was included in the title in 55% of the articles and had the highest statistically significant positive correlation to citation rate (point-biserial correlation coefficient [r pb ] = 0.85, p radiology. Using bibliometric knowledge, authors can craft a title, abstract, and text that may enhance visibility and citation count over what they would otherwise experience.

  3. Establishing diagnostic reference levels in digital radiology

    International Nuclear Information System (INIS)

    Bana, Remy Wilson

    2016-04-01

    Medical application of radiation has gained wider study since diagnostic radiology plays a very important role in modern medicine. The need of the service seems to increase since the invention of digital radiology as a new technology that promises greater accuracy while minimizing patient dose. However, it is not exempted in the harmonization of doses delivered to the patient undergoing same radiologic examination in different institutions either regional or nationwide. The objective of this project was to review the establishment of Diagnostic Reference Levels (DRLs) in digital radiology at National level with the aim to reduce patient dose while maintaining appropriate image quality. A general discussion on digital radiology has been presented focusing on the optimization of patient dose as well as dosimetric quantities used for the establishment of DRLs. Recommendations have been provided for Rwanda to initiate steps to establish National Diagnostic Reference Levels for common procedures in digital radiology. (au)

  4. Curriculum Guidelines for Predoctoral Oral Radiology.

    Science.gov (United States)

    Journal of Dental Education, 1987

    1987-01-01

    The American Association of Dental Schools' guidelines for oral radiology curricula give an overview of the field and its interrelationships with other fields and outline the primary educational objectives, prerequisites, core content, specific behavioral objectives, sequencing, faculty, facilities, and occupational hazards to be considered in…

  5. Comparison of radiology residency programs in ten countries

    International Nuclear Information System (INIS)

    Willatt, J.M.G.; Mason, A.C.

    2006-01-01

    The purpose of our study was to compare various aspects of radiology training schemes in ten countries. A questionnaire was sent to senior residents in the UK, USA, Canada, Australia, New Zealand, Italy, Egypt, India, Malaysia and Greece. The questions concerned length of training, required pre-training experience, the organization of the training scheme, teaching, resources, stages at which residents can independently perform and report examinations, fellowships, and progression to jobs. A wide variety of training, ranging from highly scheduled programs with detailed aims and objectives, to self-learning occurs across the world. Examinations and assessments are also variable. There are lessons to be learned from varying practices; more exchanges of ideas should be encouraged. In view of the ''internationalization'' of radiology services and the variation in training styles an international qualification for quality assurance purposes may be desirable. (orig.)

  6. The Ethics of Radiological Protection: A Focus on Values and Objectives

    International Nuclear Information System (INIS)

    Clement, Christopher

    2013-01-01

    Christopher Clement emphasised how the RP system is based on science, values and experience and that ethics focuses on values, normative statements, while facts as descriptive statements, are more a question of science. Even full and complete knowledge is not sufficient to decide what ought to be since it is not possible to derive statements of values (what ought to be) from statements of facts (what is). In the case of radiation effects where knowledge is far from complete, value judgements are necessary. Different types of values include aesthetics with beauty and harmony, and ethics with good and right, as values. The RP system relates to human conduct, which is about action and focus on right and wrong actions. The presentation briefly reviewed different schools of ethical though (Aristotele, Bentham and Kant) and theories of normative ethics in particular consequentialism /utilitarianism and deontology. These approaches are elegant, but have flaws. A more complex approach was presented on the basis of Ross indicating that obligations must be balanced depending on each circumstance, where ethical decisions are a matter of balancing potentially conflicting responsibilities or values. A pragmatic approach was proposed, seeking a set of values relevant to the RP system, commonly acceptable to the widest possible range of cultures. The challenge with this approach rests in clarifying the values (responsibilities/duties/obligations) related to the system of radiological protection and at the same time in clarifying the objectives in the protection of people and of the environment. A list of thoughts was proposed, in the final part of the presentation, concerning the objective of providing a reasonable level of protection to all people in medical exposures, occupational and public exposures, which includes: the recognition of the special status of children, acceptable to all, but not necessarily equal for all and a separate treatment for the very small segments of

  7. Establishment and preliminary application of the interactive tele-radiologic conference system based on virtual private network

    International Nuclear Information System (INIS)

    Wang Xuejian; Hu Jian; Wang Kang; Yu Hui; Luo Min; Lei Wenyong

    2005-01-01

    Objective: To investigate the establishment and characteristics of the interactive tele-radiological system (IATRS). Methods: Local area network (LAN) of local hospitals with firewall and ADSL Modem was connected into internet, then connected into the Virtual Private Network (VPN) server of the affiliated hospital of Guiyang Medical College (GMCAH) through anti-firewall of GMCAH. The VPN tunnel was acquired and LAN of local hospitals was connected into the PACS server of GMCAH, resulting in sharing of radiological data by both the GMCAH and local hospitals. Results: Radiological data from local hospitals could be transmitted by the PACS server of GMCAH safety and rapidly. The IATRS could provide high-quality images with high-speed, and with ease to perform. Conclusion: IATRS is useful and reliable for transmitting radiological data between remote places. (authors)

  8. Building Maintenance. Performance Objectives. Basic Course.

    Science.gov (United States)

    Taylor, Ernest

    Several intermediate performance objectives and corresponding criterion measures are listed for each of the 13 terminal objectives for a basic high school building maintenance course (the first year of a 3-year program). The materials were developed for a 36-week course (2 hours daily) designed to enable 10th grade students to develop competencies…

  9. Board characteristics, governance objectives, and hospital performance

    DEFF Research Database (Denmark)

    Thiel, Andrea; Winter, Vera; Büchner, Vera Antonia

    2018-01-01

    membership relates to board characteristics and financial performance. METHODOLOGY: Using factor analysis, we identify latent classes of governance objectives and use hierarchical cluster analysis to detect distinct clusters with varying emphasis on the classes. We then use multinomial regression to explore...... the associations between cluster membership and board characteristics (size, gender diversity, and occupational diversity) and examine the associations between clusters and financial performance using OLS regression. RESULTS: Classes of objectives reflecting three governance theories-agency theory, stewardship...... and hospital financial performance, with two of three groups performing significantly better than the reference group. CONCLUSION: High performance in hospitals can be the result of governance logics, which, compared to simple board characteristics, are associated with better financial outcomes. PRACTICE...

  10. Design aspects of radiological safety in nuclear facilities

    International Nuclear Information System (INIS)

    Patkulkar, D.S.; Purohit, R.G.; Tripathi, R.M.

    2014-01-01

    In order to keep operational performance of a nuclear facility high and to keep occupational and public exposure ALARA, radiological safety provisions must be reviewed at the time of facility design. Deficiency in design culminates in deteriorated system performance and non adherence to safety standards and could sometimes result in radiological incident. Important radiological aspects relevant to safety were compiled based on operating experiences, design deficiencies brought out from past nuclear incidents, experience gained during maintenance, participation in design review of upcoming nuclear facilities and radiological emergency preparedness

  11. Plan gauge in pediatric radiology: dosimetry (experience of ten months)

    International Nuclear Information System (INIS)

    Fraysse, V.; Lacaze, M.T.; Ferran, J.L.; Couture, A.; Gardien, E.

    2006-01-01

    The objectives were to optimize the radiological constants in the use of the sensors plans(shots) in general radiology. Definition of doses, calculation and communication to the parents of the received dose. (N.C.)

  12. Image Quality in Vascular Radiology

    International Nuclear Information System (INIS)

    Vanhavere, F.; Struelens, L.

    2005-01-01

    In vascular radiology, the radiologists use the radiological image to diagnose or treat a specific vascular structure. From literature, we know that related doses are high and that large dose variability exists between different hospitals. The application of the optimization principle is therefore necessary and is obliged by the new legislation. So far, very little fieldwork has been performed and no practical instructions are available to do the necessary work. It's indisputable that obtaining quantitative data is of great interest for optimization purposes. In order to gain insight into these doses and the possible measures for dose reduction, we performed a comparative study in 7 hospitals. Patient doses will be measured and calculated for specific procedures in vascular radiology and evaluated against their most influencing parameters. In view of optimization purposes, a protocol for dose audit will be set-up. From the results and conclusions in this study, experimentally based guidelines will be proposed, in order to improve clinical practice in vascular radiology

  13. Radiological findings in NAO syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Al-Otaibi, Leftan; Hugosson, Claes O. [Department of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia); Al-Mayouf, Sulalman M.; Majeed, Mahmoud; Al-Eid, Wea' am; Bahabri, Sultan [Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia)

    2002-07-01

    Background: Diseases exhibiting osteolysis in children are rare hereditary conditions. Several types have been recognised with different clinical manifestations. One type includes subcutaneous nodules, arthropathy and osteolysis and has been termed NAO syndrome. Previous radiological reports have described the affected bones, usually the carpal and tarsal regions, but a detailed analysis of the radiological findings of both the axial as well as the appendicular skeleton has not been reported. Objectives: To describe the radiological findings in a large group of children with an autosomal recessive disease characterized by nodules, familial arthropathy and osteolysis. Materials and methods: The study comprises 14 patients from 9 families and all patients had the triad of nodulosis, arthropathy and osteolysis (NAO). Results: The most common radiological manifestations were osteopenia, undertubulation of long bones, arthritic changes, sclerotic sutures of the calvaria, osteolysis and muscle contractures. Other common findings were squared vertebrae, broad medial clavicles and brachycephaly. Progress of disease was documented in more than half of the patients. Conclusions: Our study is the first report of the detailed radiological findings of NAO syndrome. In NAO syndrome, both the axial and appendicular skeleton are involved (orig.)

  14. Radiological findings in NAO syndrome

    International Nuclear Information System (INIS)

    Al-Otaibi, Leftan; Hugosson, Claes O.; Al-Mayouf, Sulalman M.; Majeed, Mahmoud; Al-Eid, Wea'am; Bahabri, Sultan

    2002-01-01

    Background: Diseases exhibiting osteolysis in children are rare hereditary conditions. Several types have been recognised with different clinical manifestations. One type includes subcutaneous nodules, arthropathy and osteolysis and has been termed NAO syndrome. Previous radiological reports have described the affected bones, usually the carpal and tarsal regions, but a detailed analysis of the radiological findings of both the axial as well as the appendicular skeleton has not been reported. Objectives: To describe the radiological findings in a large group of children with an autosomal recessive disease characterized by nodules, familial arthropathy and osteolysis. Materials and methods: The study comprises 14 patients from 9 families and all patients had the triad of nodulosis, arthropathy and osteolysis (NAO). Results: The most common radiological manifestations were osteopenia, undertubulation of long bones, arthritic changes, sclerotic sutures of the calvaria, osteolysis and muscle contractures. Other common findings were squared vertebrae, broad medial clavicles and brachycephaly. Progress of disease was documented in more than half of the patients. Conclusions: Our study is the first report of the detailed radiological findings of NAO syndrome. In NAO syndrome, both the axial and appendicular skeleton are involved (orig.)

  15. Radiologic image compression -- A review

    International Nuclear Information System (INIS)

    Wong, S.; Huang, H.K.; Zaremba, L.; Gooden, D.

    1995-01-01

    The objective of radiologic image compression is to reduce the data volume of and to achieve a lot bit rate in the digital representation of radiologic images without perceived loss of image quality. However, the demand for transmission bandwidth and storage space in the digital radiology environment, especially picture archiving and communication systems (PACS) and teleradiology, and the proliferating use of various imaging modalities, such as magnetic resonance imaging, computed tomography, ultrasonography, nuclear medicine, computed radiography, and digital subtraction angiography, continue to outstrip the capabilities of existing technologies. The availability of lossy coding techniques for clinical diagnoses further implicates many complex legal and regulatory issues. This paper reviews the recent progress of lossless and lossy radiologic image compression and presents the legal challenges of using lossy compression of medical records. To do so, the authors first describe the fundamental concepts of radiologic imaging and digitization. Then, the authors examine current compression technology in the field of medical imaging and discuss important regulatory policies and legal questions facing the use of compression in this field. The authors conclude with a summary of future challenges and research directions. 170 refs

  16. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  17. Plan for radiological emergencies situations

    International Nuclear Information System (INIS)

    Estrada Figueroa, E.R.

    1998-01-01

    The objective for the Emergencies plan it is to reestablish the stock that they should be executed by the regulatory Entity in Guatemala during a real potential radiological emergency situation in the national territory

  18. Regional radiological observations of the environment

    International Nuclear Information System (INIS)

    2014-11-01

    After having recalled the objective of regional radiological observations (establishment of an updated referential of radioactivity levels in some parts of the environment which are typical of the concerned territory), and indicated the three main steps of these observations (definition of a methodology which may differ from one territory to the other, sampling and analysis, assessment of the radiological status of the studied territory), this report presents a methodology which can be applied to big rivers and predominantly agricultural territories. The radiological observations of different areas are reported (Val de Loire, Rhone valley, areas of persistence like mountains, or mining areas). Maps indicate the sampling location and the analysed products (food, soil, plants) and report of the ground or aquatic environment analysis, or available data and sampling strategy are given. The New Caledonia radiological observation is also reported

  19. Radiology and social media: are private practice radiology groups more social than academic radiology departments?

    Science.gov (United States)

    Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M

    2015-05-01

    This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Evaluation system for the analysis of the radiological consequences (RASCAL)

    International Nuclear Information System (INIS)

    Miguel Martinez, M. J. de

    2011-01-01

    The code currently employed by the Spanish Nuclear power is the IRDAM (Interactive Rapid Dose Assessment Model). This code will now be replaced by the RASCAL (Radiological Assessment System for Consequence Analysis) version 4.0. This is a significant improvement in dose calculation for escapes to the atmosphere for radioactive emergencies. The main objective is to highlight the most significant changes introduced in the RASCAL when performing these dose estimates.

  1. Radiological findings and interventions for iatrogenic vascular injuries

    International Nuclear Information System (INIS)

    Lee, Kyoung Ho; Chung, Jin Wook; Kim, Tae Kyoung; Han, Sang Wook; Lee, Jong Seog; Park, Jae Hyung; Kim, Jong Hyo; Han, Man Chung

    1998-01-01

    The purpose of this study is to evaluate the radiological findings and effectiveness of radiological interventions in patients with iatrogenic vascular injuries. We analyzed 50 patients with iatrogenic vascular injuries treated with radiological intervention. The causes of injuries were surgery (n=20), cardiovascular intervention (n=15), non-cardiovascular radiological intervention (n=14), and endoscopic intervention (n=1). The injury had resulted in hemorrhage in 35 cases. The iliac and/or femoral, hepatic, and renal vessels were commonly injured. Angiography, ultrasonography with Doppler examination, CT, and CT angiography were performed to diagnose vascular injuries and guide the radiological intervention. The mean follow-up period was 23 months and in 16 cases was more than one year. the major radiological findings were extravasation, pseudoaneurysm, arteriovenous shunt, or vascular obstruction. To control these lesions, radiological interventions such as embolization (n=36), local urokinase administration, stent insertion, foreign body removal, ultrasonography-guided compression, or stent-graft insertion were performed. The clinical problems were immediately controlled by the single trials of radiological interventions and did not recur in 40 cases (80%). Radiological examinations and interventions are useful in cases with iatrogenic vascular injuries. (author). 14 refs., 4 figs

  2. Improving Site-Specific Radiological Performance Assessments - 13431

    Energy Technology Data Exchange (ETDEWEB)

    Tauxe, John; Black, Paul; Catlett, Kate; Lee, Robert; Perona, Ralph; Stockton, Tom; Sully, Mike [Neptune and Company, Inc., Los Alamos, New Mexico 87544 (United States)

    2013-07-01

    An improved approach is presented for conducting complete and defensible radiological site-specific performance assessments (PAs) to support radioactive waste disposal decisions. The basic tenets of PA were initiated some thirty years ago, focusing on geologic disposals and evaluating compliance with regulations. Some of these regulations were inherently probabilistic (i.e., addressing uncertainty in a quantitative fashion), such as the containment requirements of the U.S. Environmental Protection Agency's (EPA's) 40 CFR 191, Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes, Chap. 191.13 [1]. Methods of analysis were developed to meet those requirements, but at their core early PAs used 'conservative' parameter values and modeling approaches. This limited the utility of such PAs to compliance evaluation, and did little to inform decisions about optimizing disposal, closure and long-term monitoring and maintenance, or, in general, maintaining doses 'as low as reasonably achievable' (ALARA). This basic approach to PA development in the United States was employed essentially unchanged through the end of the 20. century, principally by the U.S. Department of Energy (DOE). Performance assessments developed in support of private radioactive waste disposal operations, regulated by the U.S. Nuclear Regulatory Commission (NRC) and its agreement states, were typically not as sophisticated. Discussion of new approaches to PA is timely, since at the time of this writing, the DOE is in the midst of revising its Order 435.1, Radioactive Waste Management [2], and the NRC is revising 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste [3]. Over the previous decade, theoretical developments and improved computational technology have provided the foundation for integrating decision analysis (DA) concepts and objective-focused thinking, plus

  3. Improving Site-Specific Radiological Performance Assessments - 13431

    International Nuclear Information System (INIS)

    Tauxe, John; Black, Paul; Catlett, Kate; Lee, Robert; Perona, Ralph; Stockton, Tom; Sully, Mike

    2013-01-01

    An improved approach is presented for conducting complete and defensible radiological site-specific performance assessments (PAs) to support radioactive waste disposal decisions. The basic tenets of PA were initiated some thirty years ago, focusing on geologic disposals and evaluating compliance with regulations. Some of these regulations were inherently probabilistic (i.e., addressing uncertainty in a quantitative fashion), such as the containment requirements of the U.S. Environmental Protection Agency's (EPA's) 40 CFR 191, Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes, Chap. 191.13 [1]. Methods of analysis were developed to meet those requirements, but at their core early PAs used 'conservative' parameter values and modeling approaches. This limited the utility of such PAs to compliance evaluation, and did little to inform decisions about optimizing disposal, closure and long-term monitoring and maintenance, or, in general, maintaining doses 'as low as reasonably achievable' (ALARA). This basic approach to PA development in the United States was employed essentially unchanged through the end of the 20. century, principally by the U.S. Department of Energy (DOE). Performance assessments developed in support of private radioactive waste disposal operations, regulated by the U.S. Nuclear Regulatory Commission (NRC) and its agreement states, were typically not as sophisticated. Discussion of new approaches to PA is timely, since at the time of this writing, the DOE is in the midst of revising its Order 435.1, Radioactive Waste Management [2], and the NRC is revising 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste [3]. Over the previous decade, theoretical developments and improved computational technology have provided the foundation for integrating decision analysis (DA) concepts and objective-focused thinking, plus a Bayesian approach to

  4. Radiological Characterization and Final Facility Status Report Tritium Research Laboratory

    International Nuclear Information System (INIS)

    Garcia, T.B.; Gorman, T.P.

    1996-08-01

    This document contains the specific radiological characterization information on Building 968, the Tritium Research Laboratory (TRL) Complex and Facility. We performed the characterization as outlined in its Radiological Characterization Plan. The Radiological Characterization and Final Facility Status Report (RC ampersand FFSR) provides historic background information on each laboratory within the TRL complex as related to its original and present radiological condition. Along with the work outlined in the Radiological Characterization Plan (RCP), we performed a Radiological Soils Characterization, Radiological and Chemical Characterization of the Waste Water Hold-up System including all drains, and a Radiological Characterization of the Building 968 roof ventilation system. These characterizations will provide the basis for the Sandia National Laboratory, California (SNL/CA) Site Termination Survey .Plan, when appropriate

  5. Evaluation of management of communication in the actions of preparedness and response to nuclear and radiological emergencies

    Energy Technology Data Exchange (ETDEWEB)

    Mello Filho, Mauro Otto de Cavalcanti; Beserra, Marcela Tatiana Fernandes, E-mail: maurootto@cefet-rj.br, E-mail: maurootto@gmail.com, E-mail: mbeserra@cefet-rj.br [Centro Federal de Educacao Celso Sucknow da Fonseca (CEFET-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica Vergara, E-mail: mwasserman@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Julio Cesar de Faria Alvim, E-mail: geowass@vm.uff.br [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2013-07-01

    The use of practices involving the use of ionizing radiation in diverse areas of knowledge increases every day. This growth warning about the increased probability of accidents, radiological and nuclear emergencies, with possible consequences for the public, workers and the environment. Within this scenario, it is clear that studies and reassessments of the emergency response actions, receive proposals for continuous improvement. The achievement of the objectives of the response must be sustained by tactical, operation and logistics optimized processes. The articulation through communication between the teams involved in the response must be adaptable to each accident or emergency, respecting its size. The objectives of this study is to perform an assessment on the management of communication in the actions of Preparedness and Response to Nuclear and Radiological Emergencies. This assessment is supported by best practices of the Incident Command System (ICS) and the Institute of Project Management (Project Management Institute-PMI). For this purpose, based on models referred were established performance indicators supported by the BSC (Balanced Scorecard). These indicators allowed to evaluate more objectively the performance of the communication processes associated with each phase of the response. The study resulted in the proposed model documents aiming to assist planning of communications exercises in preparation and response actions, supported and adapted the best practices of PMI. These methodologies were evaluated by real cases selected from radiological and nuclear emergencies published by the International Atomic Energy Agency (IAEA). (author)

  6. Evaluation of management of communication in the actions of preparedness and response to nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Mello Filho, Mauro Otto de Cavalcanti; Beserra, Marcela Tatiana Fernandes; Wasserman, Maria Angelica Vergara; Wasserman, Julio Cesar de Faria Alvim

    2013-01-01

    The use of practices involving the use of ionizing radiation in diverse areas of knowledge increases every day. This growth warning about the increased probability of accidents, radiological and nuclear emergencies, with possible consequences for the public, workers and the environment. Within this scenario, it is clear that studies and reassessments of the emergency response actions, receive proposals for continuous improvement. The achievement of the objectives of the response must be sustained by tactical, operation and logistics optimized processes. The articulation through communication between the teams involved in the response must be adaptable to each accident or emergency, respecting its size. The objectives of this study is to perform an assessment on the management of communication in the actions of Preparedness and Response to Nuclear and Radiological Emergencies. This assessment is supported by best practices of the Incident Command System (ICS) and the Institute of Project Management (Project Management Institute-PMI). For this purpose, based on models referred were established performance indicators supported by the BSC (Balanced Scorecard). These indicators allowed to evaluate more objectively the performance of the communication processes associated with each phase of the response. The study resulted in the proposed model documents aiming to assist planning of communications exercises in preparation and response actions, supported and adapted the best practices of PMI. These methodologies were evaluated by real cases selected from radiological and nuclear emergencies published by the International Atomic Energy Agency (IAEA). (author)

  7. How visual search relates to visual diagnostic performance: a narrative systematic review of eye-tracking research in radiology.

    Science.gov (United States)

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J

    2017-08-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye

  8. Comparison of the distribution of non-radiological and radiological fatal risk in Ontario industries (addendum)

    International Nuclear Information System (INIS)

    Davis, C.K.; Forbes, W.F.; Hayward, L.M.

    1986-09-01

    Occupational limits for exposure to ionizing radiation, in force in Canada, are based on recommendations of international bodies, particularly the International Commission on Radiological Protection (ICRP). To determine whether the ICRP assertions concerning the similarity of the distributions of occupational risk at the higher risk levels (from non-radiation and from radiation work) to Canada a study of the high end of the distributions of non-radiological risk of occupational fatalities in the province of Ontario was performed. For the present study total doses from exposure to sources of ionizing radiation for Ontario workers were converted to relative risk rates to allow direct comparison with the non-radiological results. In addition, absolute values for the radiological risk rates (RRR) were derived. The radiological risk estimates are based on workers who work both from nuclear reactions and from X-rays. The conclusion is made that the radiological and non-radiological risk rate (NRRR) distributions are similar in shape, but the RRR are approximately 1 to 27 percent of the NRRR, depending on the industry concerned

  9. Radiological characterisation on V1 NPP technological systems and buildings - Contamination

    International Nuclear Information System (INIS)

    Hanzel, Richard; Rapant, Tibor; Svitek, Jaroslav

    2012-01-01

    Since 2001, the preparation of V1 NPP practical decommissioning has been supported and partly financed by the Bohunice International Decommissioning Support Fund, under the administration of the European bank for Reconstruction and development. AMEC Nuclear Slovakia, together with partners STM Power and EWN GmbH, performed BIDSF B.4 project - Decommissioning database development. The main purpose of the B6.4 project was to develop a comprehensive physical and radiological inventory database to support RAW management development of the decommissioning studies and decommissioning project of Bohunice V1 NPP. AMEC Nuclear Slovakia was responsible mainly for DDB design, planning documents and physical and radiological characterization including sampling and analyses of the plant controlled area. The objective of V1 NPP radiological characterization was summarisation of sampling and analyses results, description of methodology used for radiological characterization and determination of the V1 NPP radiological inventory. Results of the characterization survey included the identification and distribution of contamination in buildings, structures, and other site facilities or other impacted media. The characterization survey clearly identified those portions of the site that have been affected by site activities and are contaminated. The survey also identified the portions of the site that have not been affected by these activities and can be marked as 'not impacted'. Radiological data have been presented also on the basis of index RAI level, where 5 radiological classes have been defined. On the basis of sampling and analyses results following radiological parameters have been assigned to all impacted components and civil structures included in DDB: dose rate in contact, dose rate in distance 1 m, external surface contamination, internal surface contamination and volume/mass contamination. Each room in controlled area has been described by following radiological parameters

  10. Radiology system evolution in the new millennium.

    Science.gov (United States)

    Nauert, R C

    2001-01-01

    establish executive focus and priorities. These should be woven into operational and capital budgets to reflect expectations of the revenues, expenses and investments tied to the plan. While formidable, all of these objectives are realistic and can be accomplished if the right decisions are made. Initially, the entity's principle business objective is to formulate and begin implementation of methodical yet aggressive strategies for growth that are sensitive to sustaining high levels of quality patient care. The next phase features mergers with large, independent radiology practices in key geographic areas and successful acquisition of smaller practices. The objective of the final phase is to aggressively expand into select metropolitan areas with regional coverage and full teleradiology capabilities. High levels of market strength and financial performance are necessary to succeed. Passive limitations to small geographic areas and narrow practices will undermine their market position and dissolve financial strength with no hope of recovery. Only the dominant systems will survive and prosper.

  11. Aspects of radiological protection in nuclear installations

    International Nuclear Information System (INIS)

    Hunt, J.G.; Oliveira Filho, D.S.; Rabello, P.N.P.

    1987-01-01

    Due to the short term, long term and genetic effects of radiation, the work with radioactive materials requires special protection measures. The objective of radiological protection is to assure the occupational health of the workers by maintaining the dose levels as low as reasonably achievable. The radiological protection measures implanted in the NUCLEBRAS fuel element factory are described. The philosophy and practical measures taken are explained, and a comparison between radiation protection and industrial safety norms is made. The result of this work shows that the radiological safety of the element factory is assured. (author) [pt

  12. Strengthening the scientific basis of radiological protection

    International Nuclear Information System (INIS)

    Lazo, Edward

    2016-01-01

    The overarching objective of the radiological protection system is to contribute to an appropriate level of protection against the harmful effects of radiation exposure, without unjustifiably limiting the desired results from the human activity causing exposure. Such a balance is achieved by understanding as best as possible the scientific characteristics of radiation exposure and the related health effects, and by taking this knowledge into consideration when judging which protection decisions will ensure the best balance between social and economic aspects and risks. In general, the existing radiological protection system, on which national regulations are built in virtually every country in the world, works well and does not underestimate protection needs for either individuals or exposed populations as a whole. The latest International Commission on Radiological Protection (ICRP) recommendations, which define this protection system, were formed after a long and open dialogue with the public, where expert views were actively collected and discussed at national, regional and international levels. Although the radiological protection system is very effective, and there is no current need for a prompt revision, it is important nonetheless to keep a watchful eye on the latest scientific results, and to work to ensure that the entire radiological protection community is kept up to date on evolving and emerging scientific issues. In this way, potential or actual scientific changes can be appropriately identified and in turn can stimulate reflection on changes that might be needed in the protection system, in policy, in regulation and in practice. Such reflection should benefit from the input of other scientific disciplines and interested stakeholders. To contribute to this process, the NEA Committee on Radiological Protection and Public Health (CRPPH) has periodically reviewed and released reports on the state of the art in radiological protection science (see NEA

  13. Patient exposure evaluation in Romanian radiological departments

    International Nuclear Information System (INIS)

    Girjoaba, O.; Cucu, A.

    2012-01-01

    Purpose: A nation-wide evaluation of ionizing radiation exposure of the Romanian population due to the radiological examinations is performed in accordance with European Directive 97/43 EURATOM implemented in national regulations. Method: The study is applied to the collected data from radiological departments from Romanian hospitals during 2010. The radiological examinations were grouped in three categories: conventional diagnostic radiology, interventional radiology and computed tomography. The annual collective dose was determined from the reported data about the mean effective doses and the frequency for each type of radiological examination, in conformity with the national regulations. Regarding the frequency aspects, the results include the age and gender distributions. Major results: More then 6 million radiological examinations were performed in 2010, Romania having a population about of 20.3 million inhabitants. The collective effective dose for 2010 resulted from the study is 152 mSv per 1000 inhabitants. Conclusions: Medical practitioners must select the best medical imaging investigation for each clinical case taking into account the importance of keeping the patient dose as low as possible. Medical physicists should be strongly involved in the establishing of the dosimetry procedures. (author)

  14. Research and development in radiological protection; Investigacion y desarrollo en proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.

    2004-07-01

    The objective of Radiological Protection is to gurantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information managmenet technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks assocaited with their definitive managmenet or thier release to the environment. Briefly desribed below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)

  15. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  16. Resources planning for radiological incidents management

    Science.gov (United States)

    Hamid, Amy Hamijah binti Ab.; Rozan, Mohd Zaidi Abd; Ibrahim, Roliana; Deris, Safaai; Yunus, Muhd. Noor Muhd.

    2017-01-01

    Disastrous radiation and nuclear meltdown require an intricate scale of emergency health and social care capacity planning framework. In Malaysia, multiple agencies are responsible for implementing radiological and nuclear safety and security. This research project focused on the Radiological Trauma Triage (RTT) System. This system applies patient's classification based on their injury and level of radiation sickness. This classification prioritizes on the diagnostic and treatment of the casualties which include resources estimation of the medical delivery system supply and demand. Also, this system consists of the leading rescue agency organization and disaster coordinator, as well as the technical support and radiological medical response teams. This research implemented and developed the resources planning simulator for radiological incidents management. The objective of the simulator is to assist the authorities in planning their resources while managing the radiological incidents within the Internal Treatment Area (ITA), Reception Area Treatment (RAT) and Hospital Care Treatment (HCT) phases. The majority (75%) of the stakeholders and experts, who had been interviewed, witnessed and accepted that the simulator would be effective to resolve various types of disaster and resources management issues.

  17. ASUPT Automated Objective Performance Measurement System.

    Science.gov (United States)

    Waag, Wayne L.; And Others

    To realize its full research potential, a need exists for the development of an automated objective pilot performance evaluation system for use in the Advanced Simulation in Undergraduate Pilot Training (ASUPT) facility. The present report documents the approach taken for the development of performance measures and also presents data collected…

  18. Streamlining interventional radiology admissions: The role of the interventional radiology clinic and physician's assistant

    International Nuclear Information System (INIS)

    White, R.I. Jr.; Rizer, D.M.; Shuman, K.; White, E.J.; Adams, P.; Doyle, K.; Kinnison, M.

    1987-01-01

    During a 5-year period (1982-1987), 376 patients were admitted to an interventional radiology service where they were managed by the senior physician and interventional radiology fellows. Sixty-eight percent of patients were admitted for angioplasty and 32% for elective embolotherapy/diagnostic angiography. A one-half-day, twice weekly interventional radiology clinic and employment of a physician's assistant who performed preadmission history and physicals and wrote orders accounted, in part, for a decrease in hospital stay length from 3.74 days (1982-1983) to 2.41 days (1986-1987). The authors conclude that use of the clinic and the physician's assistant streamlines patient flow and the admitting process and is partially responsible for a decreased length of stay for patients admitted to an interventional radiology service

  19. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  20. Radiological Evaluation Standards in the Radiology Department of Shahid Beheshti Hospital (RAH YASUJ Based on Radiology standards in 92

    Directory of Open Access Journals (Sweden)

    A َKalantari

    2014-08-01

    Full Text Available Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descriptive statistics. Results: 87.3% of the students chose the cassette, 76.3%, patients chose the position, 87.3%, member state, the central ray 83.9%, and the distance between the tube and the patient 68.6% had been operated in accordance with the standards practice. Among all the factors and variables, between view with cassette, view with SID, sex with position patients, grid with central ray, grid with SID, Request with positioning the patient and between density with patient position and member position significant relationship were observed p<0.05 . Conclusions: Staff and students in terms of performance were at high levels, but in the levels of protection were in poor condition. Therefore, in order to promote their conservation, education and periodical monitoring should be carried out continuously.

  1. The radiological technologist

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    Radiologists rely upon the talents of the technologists with whom they work. Indeed, a good technologist will only enhance the radiologist's performance. Radiological technologists no longer solely take radiographs, but are involved in many more detailed areas of imaging, such as computered tomography, magnetic resonance imaging, nuclear radiology, ultrasound, angiography, and special procedures. They are also required to make decisions that affect the radiological examination. Besides the degree in radiological technology (RT), advanced degrees in nuclear medicine technology (NMT) and diagnostic medical sonography (RDMS) are attainable. The liability of the technologist is not the same as the radiologist involved, but the liability is potentially real and governed by a subdivision of jurisprudence known as agency law. Since plaintiffs and attorneys are constantly searching for new frontiers of medical liability, it is wise for the radiologist and technologist to be aware of the legalities governing their working relationship and to behave accordingly. The legal principles that apply to this working relationship are discussed in this chapter, followed by a presentation of some relevant and interesting cases that have been litigated

  2. Retroperitoneal fibrosis: the clinical and radiological manifestation

    International Nuclear Information System (INIS)

    Pan Weidong; Zhao Rongguo; Qin Mingwei; Xue Huadan; Liang Jixiang

    2005-01-01

    Objective: To analyze the clinical and radiological features of retroperitoneal fibrosis (RPF), and to deepen the understanding of this unusual disease and improve the diagnostic level at the early stage. Methods: Fourteen cases (10 males and 4 females, mean age 45.8 years) of pathologically diagnosed RPF from January 1990 to June 2004 were summarized. The clinical and radiological performance of the cases were analyzed. All patients received non-contrast CT scanning, 10 of them underwent enhanced CT scanning as well. 8 patients received MRI, 10 patients received IVP examination, and 11 received B-ultrasound. Results: (1) The very first symptoms usually included back pain, bellyache (10 cases), or urinary tract obstruction (3 cases), with increase of ESR, IgG, CRP value and abnormal renal function. (2) The result of radiological examination showed that 11 lesions of the 14 cases located at retroperitoneum. Ten cases were mass type and 4 cases were diffuse type. Non-contrast CT scanning revealed soft tissue mass at retroperitoneum with in homogenous or homogenous density. After contrast medium injection the lesions were enhanced with different extent. MRI results showed that the lesions presented low signal in T 1 WI, while in T 2 WI the signals had no obvious coherence but were different from one case to another. Conclusion: Radiological examination is one of the important methods for diagnosis of RPF. Based on the different characteristics of RPF in CT and MRI, together with the clinical findings, we will get valuable references for staging and follow-up of RPF. (authors)

  3. Evaluation of medical radiation exposure in pediatric interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Valeria Coelho Costa; Navarro, Marcus Vinicius Teixeira; Oliveira, Aline da Silva Pacheco, E-mail: vccnavarro@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil); Maia, Ana Figueiredo [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Oliveira, Adriano Dias Dourado [Sociedade Brasileira de Hemodinamica e Cardiologia Intervencionista, Salvador, BA (Brazil)

    2012-07-15

    Objective: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. Materials and Methods: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. Results: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm{sup 2} and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm{sup 2} and 961.0 mGy. Conclusion: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates. (author)

  4. Paying for performance: Performance incentives increase desire for the reward object.

    Science.gov (United States)

    Hur, Julia D; Nordgren, Loran F

    2016-09-01

    The current research examines how exposure to performance incentives affects one's desire for the reward object. We hypothesized that the flexible nature of performance incentives creates an attentional fixation on the reward object (e.g., money), which leads people to become more desirous of the rewards. Results from 5 laboratory experiments and 1 large-scale field study provide support for this prediction. When performance was incentivized with monetary rewards, participants reported being more desirous of money (Study 1), put in more effort to earn additional money in an ensuing task (Study 2), and were less willing to donate money to charity (Study 4). We replicated the result with nonmonetary rewards (Study 5). We also found that performance incentives increased attention to the reward object during the task, which in part explains the observed effects (Study 6). A large-scale field study replicated these findings in a real-world setting (Study 7). One laboratory experiment failed to replicate (Study 3). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Pediatric radiology fellows' experience with intussusception reduction

    International Nuclear Information System (INIS)

    Stein-Wexler, Rebecca; Bateni, Cyrus; Wootton-Gorges, Sandra L.; Li, Chin-Shang

    2011-01-01

    Intussusception reduction allows young children to avoid surgery. However, graduating residents have had relatively little training in intussusception reduction and, for the most part, consider themselves ill-prepared to perform this procedure. The goal of this study was to assess the extent of training in intussusception reduction during one year of a pediatric radiology fellowship and to determine whether graduating fellows consider themselves adequately trained in this technique. Pediatric radiology fellows were surveyed during June 2010 and asked to characterize their fellowship, to indicate the number of intussusception reductions performed (both the total number and those performed with faculty oversight but without active faculty involvement), and to assess the adequacy of their training. There were 31 responses, representing almost 1/3 of current fellows. Pediatric radiology fellows perform on average 6.9 reductions, 3.8 of which are with faculty oversight but without active faculty involvement. Ninety percent consider themselves well-trained in the technique, whereas 10% are uncertain (none consider their training inadequate). Almost all pediatric radiology fellows consider their training in intussusception reduction to be adequate. (orig.)

  6. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  7. Practical interventional radiology

    International Nuclear Information System (INIS)

    Lammer, J.; Schreyer, H.

    1991-01-01

    The book is intended as a practical guide and manual for interventional radiology applications. Main emphasis is placed on the performance of the various techniques, with explanations of the various steps to be taken, illustrated by drawings or pictures. Indications, contra-indications and clinical achievements are given in brief. There is one chapter each for the following techniques: angioplasty - intra-arterial fibrinolysis - vascular stents - neuroembolisation - embolisation of other vessels - biliary interventions - abscess drainage - nephrostomy and ureteral manipulations -percutaneous fine-needle biopsy - vena cava filters - interventional radiology in infants. (orig.)

  8. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  9. Radiological field survey problems and solutions

    International Nuclear Information System (INIS)

    Deming, E.J.; Boerner, A.J.

    1986-01-01

    Situations often arise during radiological field surveys which require the health physicist to improvise and/or make spot decisions. At times these situations can be humorous, but they can also present hazards more serious than normal radiological considerations. This presentation will depict various problematic situations encountered by Oak Ridge Associated Universities Radiological Site Assessment Program in the course of performing field environmental surveys. Detailing these potential hazards can alert other field survey groups to problems they may encounter

  10. A clinical and radiological objective tumor response with somatostatin analogs (SSA in well-differentiated neuroendocrine metastatic tumor of the ileum: a case report

    Directory of Open Access Journals (Sweden)

    De Divitiis C

    2015-03-01

    Full Text Available Chiara De Divitiis,1 Claudia von Arx,2 Roberto Carbone,3 Fabiana Tatangelo,4 Elena di Girolamo,5 Giovanni Maria Romano,1 Alessandro Ottaiano,1 Elisabetta de Lutio di Castelguidone,3 Rosario Vincenzo Iaffaioli,1 Salvatore Tafuto1 On behalf of the European Neuroendocrine Tumor Society (ENETS Center of Excellence Multidisciplinary Group for Neuroendocrine Tumors in Naples (Italy 1Department of Abdominal Oncology, National Cancer Institute “Fondazione G. Pascale”, Naples, Italy; 2Department of Clinical Medicine and Surgery, “Federico II” University, Naples, Italy; 3Department of Radiology, 4Department of Pathology, 5Department of Endoscopy, National Cancer Institute “Fondazione G Pascale”, Naples, Italy Abstract: Somatostatin analogs (SSAs are typically used to treat the symptoms caused by neuroendocrine tumors (NETs, but they are not used as the primary treatment to induce tumor shrinkage. We report a case of a 63-year-old woman with a symptomatic metastatic NET of the ileum. Complete symptomatic response was achieved after 1 month of treatment with SSAs. In addition, there was an objective response in the liver, with the disappearance of secondary lesions noted on computed tomography scan after 3 months of octreotide treatment. Our experience suggests that SSAs could be useful for downstaging and/or downsizing well-differentiated NETs, and they could allow surgery to be performed. Such presurgery therapy could be a promising tool in the management of patients with initially inoperable NETs. Keywords: neuroendocrine tumor, somatostatin analogs, octreotide, metastatic tumor of the ileum, radiological tumor response

  11. Introducing a performance-based objective clinical examination into ...

    African Journals Online (AJOL)

    Purpose: To describe how a formative Objective Structured Clinical Examination was applied to fourth year pharmacy students at a university in Northern Cyprus. Methods: A blueprint-guided performance-based objective clinical examination was implemented. Group-prepared case scenarios based on course objectives ...

  12. Surgical treatment of acetabular fractures: clinical and radiological results and its complications

    International Nuclear Information System (INIS)

    Martinez, C; Rey, R.

    2011-01-01

    The objective of this work is to analyse a serie of consecutive cases of surigically treated acetabular fractures, evaluating middle-term clinical and radiological results. A retrospective analysis of clinical histories, surgical forms and X-rays was performed for 42 patients who underwent surgery in two centers (Instituto Nacional de Ortopedia y Traumatologia [INOT] and Banco de Protesis), from July 2001 through August 2007

  13. Radiological safety and control

    International Nuclear Information System (INIS)

    Kim, Jang Hee; Kim, Ki Sub

    1995-01-01

    The practical objective of radiological safety control is intended for achievement and maintenance of appropreately safe condition in environmental control for activities involving exposure from the use of radiation. In order to establish these objectives, we should be to prevent deterministic effects and to limit the occurrence stochastic effects to level deemed to be acceptable by the application of general principles of radiation protection and systems of dose limitation based on ICRP recommendations. 34 tabs., 19 figs., 11 refs. (Author) .new

  14. Radiological Work Planning and Procedures

    CERN Document Server

    Kurtz, J E

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In add...

  15. Gonad Shielding for Patients Undergoing Conventional Radiological Examinations: Is There Cause for Concern?

    Directory of Open Access Journals (Sweden)

    Karami

    2016-04-01

    Full Text Available Background Gonad shielding is one of the fundamental methods by which to protect reproductive organs in patients undergoing conventional radiological examinations. A lack of or inadequate shielding of the gonads may increase the exposure of these organs and result in malignancies future generations. Objectives The aim of this study is to investigate the prevalence of gonad shielding in patients undergoing conventional radiological examinations and the availability of gonad shields and gonad shielding protocols in radiology departments. Materials and Methods A retrospective, observational cross-sectional study on the application of gonad shielding, the availability of gonad shields and the existence of gonad shielding protocols in radiology departments was performed in five different hospitals in Ahvaz, Iran. Results The highest application of gonad shielding was 6.6% for the pediatric hospital. The prevalence of gonad shielding was less than 0.2%. In 64.3% of the radiography rooms, at least one flat-contact gonad shield of a large size was available. Only large-sized gonad shields were available. Curved-contact and shadow gonad shields did not exist. Gonad shielding protocols were not existence in any of the fourteen radiography rooms investigated. Conclusions Comprehensive protection programs with on-the-job training courses for staff members are strongly recommended, as well as, the provision of radiological shields and gonad shielding protocols in radiology departments to reduce the patient’s radiation dose during radiological examinations.

  16. Service Station Attendant. Performance Objectives. Basic Course.

    Science.gov (United States)

    Davis, John

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 24 terminal objectives for a basic secondary level service station attendant course. The materials were developed for a two-semester course (2 and 3 hours daily). The specialized classroom and shop experiences are designed to enable the student…

  17. Gasoline Engine Mechanics. Performance Objectives. Intermediate Course.

    Science.gov (United States)

    Jones, Marion

    Several intermediate performance objectives and corresponding criterion measures are listed for each of six terminal objectives presented in this curriculum guide for an intermediate gasoline engine mechanics course at the secondary level. (For the beginning course guide see CE 010 947.) The materials were developed for a two-semester (2 hour…

  18. Attention for pediatric interventional radiology

    International Nuclear Information System (INIS)

    Zhu Ming; Cheng Yongde

    2005-01-01

    Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae

  19. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.

    1992-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis, and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. Experiments performed from May 1991--April 1992 are described

  20. Pediatric radiology for medical-technical radiology assistants/radiologists

    International Nuclear Information System (INIS)

    Oppelt, Birgit

    2010-01-01

    The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.

  1. A radiological control implementation guide

    International Nuclear Information System (INIS)

    Hamley, S.A.

    1993-01-01

    A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program. The manual is now in draft form and includes information that will be of use to line managers dealing with improving radiological performance and the practical aspects of radiological controls implementation. The manual is expected to be completed by the fall of 1993 and to be used in conjunction with a performance-based self-assessment training program at the Oak Ridge National Laboratory

  2. Radiological protection. Textbook for radiographers and reference book for radiological safety officers

    International Nuclear Information System (INIS)

    Stieve, F.E.; Stargardt, A.; Stender, H.S.

    1996-01-01

    The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe) [de

  3. Knowledge and Attitude of Radiology Technologists Towards Cardiopulmonary Resuscitation

    Directory of Open Access Journals (Sweden)

    Behroozi

    2015-04-01

    Full Text Available Background The number of casualties and critically ill patients referred to radiology departments increased during the past decade, which caused the risk of cardiac arrest in radiology departments to increase considerably. Objectives The current study aimed to evaluate the knowledge and attitude of radiology technologists regarding Cardiopulmonary Resuscitation (CPR. Patients and Methods After approval a cross sectional study was designed. Ninety five radiology technologists (male and female were selected in four tertiary referral hospitals in Ahvaz, Iran. Accordingly, 87 radiologic technologists of which agreed to participate in the study. The researchers developed a questionnaire. The questionnaire consisted of three distinct sections including demographic data, attitude, and technical knowledge questions. Reliability of the technical knowledge questions were evaluated using Cronbach’s alpha (76%. Data collection was performed using interview method. Results Of the total 87 questionnaires, one was incomplete. None of the participants had attended a training program since employment. The average scores of attitude towards CPR and technical knowledge were 80 ± 8.9 and 8.8 ± 2.3, respectively. A correlation was observed between age and work experience (r = 0.866, P ≤ 0.0001, age and technical knowledge (r = 0.380, P ≤ 0.0001, work experience and technical knowledge (r = 0.317, P = 0.003, and attitude and technical knowledge (r = 0.397, P ≤ 0.0001. Also a correlation was observed between work experience and attitude (r = 0.385, P ≤ 0.0001. No significant difference was observed between male and female subjects’ technical knowledge (P ≥ 0.05 and attitude (P ≥ 0.05. Conclusions It can be concluded that, although the attitude of participants towards CPR was positive in general, their technical knowledge was poor. This finding should urge decision-makers to consider delivering in-service training courses to radiology technologists

  4. Custodial Services and Building Maint: Performance Objectives.

    Science.gov (United States)

    Downing, Charles; And Others

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 14 terminal objectives for high school custodial service and building maintenance course (the third year of a 3-year program). The materials were developed for a 36-week course (3 hours daily) designed to prepare 12th graders with entry level…

  5. Effectiveness of a radiology-anatomy instructional module in a clinical course on oral radiology

    International Nuclear Information System (INIS)

    Imanaka, Masahiro; Tamaki, Yoh; Nomura, Yoshiaki

    2007-01-01

    An insufficient knowledge of anatomy often complicates the interpretation of radiological findings by students learning clinical medicine. During a 3-week clinical course in oral radiology, students attended lectures on anatomy for half of each day. Our objectives were to evaluate this program and determine why some students remained unmotivated to learn anatomy. Surveys were carried out using two questionnaires, one for evaluating the students' beliefs regarding the necessity of knowing anatomy and their understanding of radiology and anatomy, and the other for determining the value of the educational program. In total, 126 questionnaires were analyzed. Structural equation modeling and decision analysis were used to analyze the data obtained. Beliefs regarding the necessity of knowing anatomy were explained by three variables: the necessity of knowing imaging anatomy, the necessity of knowing gross anatomy, and understanding of anatomy. Awareness of the necessity of knowing anatomy and understanding of graphical images were not strongly correlated. The educational program was characterized by two factors: 'value' and 'appropriateness' These were strongly correlated. Student interest in the content of the course was found to be the most important factor in student evaluations of the educational program. Students who answered 'agree', 'disagree' or 'strongly disagree' to three items, interested in the content of the course', 'obtained knowledge through the course' and 'expected the course to be useful in the near future were likely to have insufficient understanding of and awareness of the necessity of radiology and anatomy. The inclusion of lectures on anatomy is beneficial for improving student understanding of oral radiology. Student interest in the content is important in evaluations of radiology-anatomy programs. (author)

  6. Integrative teaching in Radiology. A survey

    International Nuclear Information System (INIS)

    Dettmer, S.; Weidemann, J.; Wacker, F.; Fischer, V.

    2015-01-01

    To survey integrative teaching in radiology at German universities. A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. The survey was considered representative with a return rate of 68%. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called 'Modellstudiengaengen' (model courses of study) (100%) compared to conventional courses of study (72%). The advantages of integrative teaching include linking of content (92%) and preparation for interdisciplinary work (76%). The disadvantages include high effort (75%) and time (67%) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84%) compared to integrative courses (76%). Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology.

  7. Conditions of radiological protection in the health unities

    International Nuclear Information System (INIS)

    Sa, L.R.B.S.; Neto, A.T.; Pires, A.; Azevedo, H.F.; Boasquevisque, E.M.

    1987-01-01

    The objective of this study was explained which conditions is practiced for occupational and environmental radiological protection. Fifteen hospitables and ambulatories services, pertaining to the public system are studies, verifying that the professional group that are preoccupied with the radioprotection conditions are the assistants services and technician. The common knowledge about Basic Standards of Radiological Protection was also observed, of which is rather precarious. (C.G.C.) [pt

  8. The Radiological Research Accelerator Facility

    International Nuclear Information System (INIS)

    Hall, E.J.; Marino, S.A.

    1993-05-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) - formerly the Radiological Research Laboratory of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. This report provides a listing and brief description of experiments performed at RARAF during the May 1, 1992 through April 30, 1993

  9. Acute traumatic central cord syndrome: analysis of clinical and radiological correlations.

    Science.gov (United States)

    Miranda, P; Gomez, P; Alday, R

    2008-12-01

    In patients with traumatic spinal cord injury, several studies correlate neurological impairment and radiological findings. However, little information is available about this correspondence in the particular group of acute traumatic central cord syndrome. The object of the present work was to describe the clinical and radiological features of a series of patients presenting with acute traumatic central cord syndrome and to analyze clinical and radiological correlations on admission and at last follow-up. Retrospective review of 15 patients diagnosed of acute traumatic central cord syndrome between 1995 and 2005. Global motor score and motor score in upper extremities were determined on admission and at last follow-up (6 months-4 years, mean 16 months). Plain films, cervical computed tomography and magnetic resonance (MR) were performed in every patient and retrieved for the study. In seven patients, serial MR studies were performed during follow-up. Clinical and radiological correlations were statistically analyzed with non-parametric tests. Cervical spondylosis appeared associated with older age, falls, and absence of fracture. Spinal cord edema was the most common finding in MR studies but hemorrhage was also observed. The length of spinal cord edema significantly correlated with initial motor score. The decrease in T2-weighted hyperintensity in serial MR studies correlated with the gain of motor power in upper limbs at last follow-up. Elderly patients with more degenerated cervical spines commonly develop acute traumatic central cord syndrome after incidental falls. Length of spinal cord edema correlates with neurological impairment on admission and may provide significant prognostic information.

  10. Implementation of a Radiological Safety Coach program

    Energy Technology Data Exchange (ETDEWEB)

    Konzen, K.K. [Safe Sites of Colorado, Golden, CO (United States). Rocky Flats Environmental Technology Site; Langsted, J.M. [M.H. Chew and Associates, Golden, CO (United States)

    1998-02-01

    The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets.

  11. Implementation of a Radiological Safety Coach program

    International Nuclear Information System (INIS)

    Konzen, K.K.

    1998-01-01

    The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets

  12. Relevant radiological anatomy of the pig as a training model in interventional radiology

    International Nuclear Information System (INIS)

    Dondelinger, R.F.; Ghysels, M.P.; Brisbois, D.; Donkers, E.; Snaps, F.R.; Saunders, J.; Deviere, J.

    1998-01-01

    The use of swine for teaching purposes in medicine and surgery has largely increased in recent years. Detailed knowledge of the porcine anatomy and physiology is a prerequisite for proper use of pigs as a teaching or an experimental model in interventional radiology. A systematic study of the radiological anatomy was undertaken in more than 100 female pigs aged 6-8 weeks. All studies were performed under general anesthesia in a single session. Animals were sacrificed at the end of the study. Selective angiographies were systematically obtained in all anatomical territories. In other animals CT and MRI examinations were performed and were correlated to anatomical sections and acrylic casts of the vascular structures. Endoscopical examinations of the upper gastrointestinal tract, including retrograde opacification of the biliary and pancreatic ducts, were added in selected animals. The main angiographic aspects of the brain, head and neck, thorax, abdomen, and pelvis were recorded. Similarities and differences in comparison with human anatomy are stressed. Potential applications in interventional radiology are indicated. (orig.)

  13. Research on photoconductor radiological sensors

    International Nuclear Information System (INIS)

    Beaumont, Francois

    1989-01-01

    Because of the evolution of medical imaging techniques to digital systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radio-graphed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo carrier trapping at dielectric-photoconductor structure interface. The reading system needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging system. The originality of thermos-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen system consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr

  14. Support for external validity of radiological anatomy tests using volumetric images

    NARCIS (Netherlands)

    Ravesloot, Cécile J.; van der Gijp, Anouk; van der Schaaf, Marieke F.; Huige, Josephine C B M; Vincken, Koen L.; Mol, Christian P.; Bleys, Ronald L A W; ten Cate, Olle T.; van Schaik, Jan P J

    2015-01-01

    Rationale and Objectives: Radiology practice has become increasingly based on volumetric images (VIs), but tests in medical education still mainly involve two-dimensional (2D) images. We created a novel, digital, VI test and hypothesized that scores on this test would better reflect radiological

  15. Support for external validity of radiological anatomy tests using volumetric images

    NARCIS (Netherlands)

    Ravesloot, Cecile J.; van der Gijp, Anouk; van der Schaaf, Marieke F; Huige, Josephine C B M; Vincken, Koen L; Mol, Christian P; Bleys, Ronald L A W; ten Cate, Olle T; van Schaik, JPJ

    2015-01-01

    RATIONALE AND OBJECTIVES: Radiology practice has become increasingly based on volumetric images (VIs), but tests in medical education still mainly involve two-dimensional (2D) images. We created a novel, digital, VI test and hypothesized that scores on this test would better reflect radiological

  16. Radiological Worker Training: Radiological Worker 2 study guides

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable

  17. Radiological Work Planning and Procedures

    International Nuclear Information System (INIS)

    KURTZ, J.E.

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In addition, there seems to be confusion as to what should be and what should not be included in the TWD

  18. Shielding in biomedical radiology site

    International Nuclear Information System (INIS)

    Bergamini, C.; Berardi, P.; Fabbri, E.

    2007-01-01

    The implementation of a proposed project of radiation protection for diagnostic radiology room may present some difficulties but in practice must be applied operational considerations that make some projects difficult if you must pursue the objectives of the principle of optimization applied to technical problems, dosimetric, economic and social

  19. ICRP PUBLICATION 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology

    International Nuclear Information System (INIS)

    Khong, P-L.; Ringertz, H.; Donoghue, V.; Frush, D.; Rehani, M.; Appelgate, K.; Sanchez, R.

    2013-01-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities – radiography and fluoroscopy, interventional radiology, and computed tomography – are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation

  20. Evaluating Multiple Object Tracking Performance: The CLEAR MOT Metrics

    Directory of Open Access Journals (Sweden)

    Bernardin Keni

    2008-01-01

    Full Text Available Abstract Simultaneous tracking of multiple persons in real-world environments is an active research field and several approaches have been proposed, based on a variety of features and algorithms. Recently, there has been a growing interest in organizing systematic evaluations to compare the various techniques. Unfortunately, the lack of common metrics for measuring the performance of multiple object trackers still makes it hard to compare their results. In this work, we introduce two intuitive and general metrics to allow for objective comparison of tracker characteristics, focusing on their precision in estimating object locations, their accuracy in recognizing object configurations and their ability to consistently label objects over time. These metrics have been extensively used in two large-scale international evaluations, the 2006 and 2007 CLEAR evaluations, to measure and compare the performance of multiple object trackers for a wide variety of tracking tasks. Selected performance results are presented and the advantages and drawbacks of the presented metrics are discussed based on the experience gained during the evaluations.

  1. Quality management systems in radiology

    Directory of Open Access Journals (Sweden)

    Geoffrey K. Korir

    2013-08-01

    Objective: To assess the level of quality management systems in X-ray medical facilities in Kenya. Methods: Quality management inspection, quality control performance tests and patient radiation exposure were assessed in 54 representative X-ray medical facilities. Additionally, a survey of X-ray examination frequency was conducted in 140 hospitals across the country. Results: The overall findings placed the country’s X-ray imaging quality management systems at 61±3% out of a possible 100%. The most and the least quality assurance performance indicators were general radiography X-ray equipment quality control tests at 88±4%, and the interventional cardiology adult examinations below diagnostic reference level at 25±1%, respectively. Conclusions: The study used a systematic evidence-based approach for the assessment of national quality management systems in radiological practice in clinical application, technical conduct of the procedure, image quality criteria, and patient characteristics as part of the quality management programme.

  2. Interdepartmental circular on nuclear and radiological emergency exercises

    International Nuclear Information System (INIS)

    2011-01-01

    This document deals with the planning of nuclear and radiological emergency exercises for 2012 in France. It discusses the return on experience of these exercises, identifies the national objectives for 2012, and indicates the exercise agenda for 2012 and predictions for 2013. The appendix is a guide for the preparation and assessment of these exercises. It indicates the concerned references and regulations, describes the classification of these exercises, and indicates how they must be prepared, performed and reported, how they must be assessed, and the different aspects which must be addressed in terms of return on experience

  3. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  4. Radiation Protection in Interventional Radiology. Training objectives for the medical specialists

    International Nuclear Information System (INIS)

    Ruiz-Cruces, R.; Vano, E.; Hernandez Armas, J.; Carrera, F.

    2003-01-01

    The Directive 97/43 Euratom on medical exposures and the report RP 116 published by the European Commission on Education and Training in radiation protection for medical exposures, established that interventional radiologists should have a more skilled training for handling X-Ray equipment and a better knowledge about the ways of protecting patients and staff against ionising radiation. To analyse the objectives for training in radiation protection recommended in the European Guideline and to show the most important points and modifications for a better practical application of this guide. An inquiry has been performed into the specific objectives recommended by the European Guideline RP 116 about training on Radiation Protection. Twenty interventional radiologists were requested to fill in the test, pointing out the importance of each objective (0-no necessary, 1-medium importance, 2-very important), and they were encouraged to suggest other more interesting for them not included in the European Guideline. The average scores for each of the objectives included in the European Guideline are shown, and an additional relation of suggested topics has been added to the current list. The scoring system show the priority and importance of the objectives that could be taken into account during the next training courses to be held in Spain and it could be used as a base of discussion in some European meeting in order to improve the European Guideline in the future. (Author) 13 refs

  5. Joints and Strings: Body and Object in Performance

    Directory of Open Access Journals (Sweden)

    Esa Kirkkopelto

    2016-07-01

    Full Text Available This article concerns the ontological status of the performing body. What if it were not considered derivative in relation to any kind of discursive construction or any kind of pre-existent materiality or force? What if it were taken as a starting point of our attempts to understand the linguistic and material aspects of our bodily co-existence? If so, our ideas of what a body can do while performing, and what it consists of, have to change radically. The anatomy of the performing body is studied through a series of scenic experiments and practical examples, and the argumentation rests on the evidence thus provided. On the philosophical level the discussion focuses on ’object-oriented ontology’ and its representatives. The indications are that our understanding of objects, objectivity and things in general is based on our understanding of bodies as linguistic entities. Becoming a performing body means becoming a linguistic body, and vice versa. This does not take us back to ‘transcendentalism’ or ‘correlationism’, however. The equality of all things, claimed by ‘ooo’ proponents, can only be achieved via the medium of the performing body as an equalizing instance.

  6. Normal or abnormal?, That is the question. Anatomical Osteomuscular Variants in Pediatric Radiology

    International Nuclear Information System (INIS)

    Ferreira, Hugo H; Garcia, Carlos A

    2009-01-01

    The objective is to describe some normal radiological variants that can cause diagnostic errors being interpreted as abnormal. Method: Its present some radiologic cases from San Ignacio Hospital and Reina Sofia Clinic of some patients with different clinical scenarios, in whom a simple radiograph was obtained. The radiologic findings are described. Results: Radiologic findings observed in these patients are normal anatomic variants, there were confirmed by a literature review. Conclusion: There are innumerable radiologic variants in the human body anatomy. It is important to know them, in order to prevent diagnostic errors and unnecessary studies.

  7. The Performance of an Object-Oriented, Parallel Operating System

    Directory of Open Access Journals (Sweden)

    David R. Kohr, Jr.

    1994-01-01

    Full Text Available The nascent and rapidly evolving state of parallel systems often leaves parallel application developers at the mercy of inefficient, inflexible operating system software. Given the relatively primitive state of parallel systems software, maximizing the performance of parallel applications not only requires judicious tuning of the application software, but occasionally, the replacement of specific system software modules with others that can more readily respond to the imposed pattern of resource demands. To assess the feasibility of application and performance tuning via malleable system software and to understand the performance penalties for detailed operating system performance data capture, we describe a set of performance instrumentation techniques for parallel, object-oriented operating systems and a set of performance experiments with Choices, an experimental, object-oriented operating system designed for use with parallel sys- tems. These performance experiments show that (a the performance overhead for operating system data capture is modest, (b the penalty for malleable, object-oriented operating systems is negligible, but (c techniques are needed to strictly enforce adherence of implementation to design if operating system modules are to be replaced.

  8. Decreased attention to object size information in scale errors performers.

    Science.gov (United States)

    Grzyb, Beata J; Cangelosi, Angelo; Cattani, Allegra; Floccia, Caroline

    2017-05-01

    Young children sometimes make serious attempts to perform impossible actions on miniature objects as if they were full-size objects. The existing explanations of these curious action errors assume (but never explicitly tested) children's decreased attention to object size information. This study investigated the attention to object size information in scale errors performers. Two groups of children aged 18-25 months (N=52) and 48-60 months (N=23) were tested in two consecutive tasks: an action task that replicated the original scale errors elicitation situation, and a looking task that involved watching on a computer screen actions performed with adequate to inadequate size object. Our key finding - that children performing scale errors in the action task subsequently pay less attention to size changes than non-scale errors performers in the looking task - suggests that the origins of scale errors in childhood operate already at the perceptual level, and not at the action level. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. The Pathology of Infection in the Department of Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Radiology, Dong a University Medical Center, Pusan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Nuclear Medicine, Pusan National University Hospital, Pusan (Korea, Republic of)

    2012-09-15

    This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

  10. The Pathology of Infection in the Department of Radiology

    International Nuclear Information System (INIS)

    Shin, Seong Gyu; Lee, Hyo Yeong

    2012-01-01

    This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

  11. Mission and activities of the International Commission on Radiological Protection

    International Nuclear Information System (INIS)

    Clements, C.H.

    2018-01-01

    The International Commission on Radiological Protection (ICRP), formed in 1928, develops the System of Radiological Protection for the public benefit. The objective of the recommendations is to contribute to an appropriate level of protection for people and the environment against the harmful effects of radiation exposure without unduly limiting the individual or societal benefits of activities involving radiation. In developing its recommendations, ICRP considers advances in scientific knowledge, evolving social values, and practical experience. These recommendations are the basis of radiological protection standards and practice worldwide

  12. Mission Analysis for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, Brooke R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wood-Zika, Annmarie R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haynes, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Klemic, Gladys A. [US Dept. of Homeland Security National Urban Security Technology Lab., Manhattan, NY (United States); Musolino, Stephen V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-01

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection (PRND) equipment to provide state and local agencies with scientific guidance on how to effectively use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed by technology manufacturers and purchased by responders for preventive detection and source interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management (CM) response take place, as it is currently the most widely available and fielded radiological instrumentation by state and local agencies. This effort will provide scientific guidance on the most effective way to utilize this class of equipment for consequence management missions. Gaining a better understanding of how PRND equipment can operate and perform for these missions will allow for recommendations on the tactical approach responders can use for consequence management operations. PRND equipment has been placed into service by federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be leveraged to support the emergency response in the aftermath of a radiological or nuclear event. With several hundred makes and models of PRND equipment, often with significantly different detection capabilities that do not align with their nominal PRND equipment type, development of a streamlined categorization scheme with respect to consequence management missions was the first step to identifying safe and effective uses of PRND equipment for radiological/nuclear incident response.

  13. Preliminary radiological readings on the old uraniferous mining site of Rophin (Puy-de-Dome); Releves radiologiques preliminaires sur l'ancien site minier uranifere de Rophin (Puy de Dome)

    Energy Technology Data Exchange (ETDEWEB)

    Chareyron, Bruno

    2012-05-02

    After a presentation of the site, of the objectives, limits and methodology of the measurement campaign, this document reports and comments the radiological measurements performed by the CRIIRAD on the old uranium mining site of Rophin and its surroundings (gamma radiation). It comments measurements performed 1 meter above the ground and on soils, and anomalies clearly related to past industrial activities. It comments the results of a radiological analysis performed on released waters (uranium 238, radon 222), and on sediments and soils

  14. Performing Materiality: Rethinking the Subject-Object Relationship as a Site of Exchange in Performance Practice

    OpenAIRE

    Hussein, Nesreen

    2011-01-01

    This thesis reconsiders the relationship between the human subject and the physical object in performance practice, which has been commonly perceived within hierarchical systems of instrumentalisation. The thesis demonstrates that in processes of performance making and reception, the role of physical objects goes beyond mimesis and direct representation. Physical objects and materials have the capacity to take active parts in a complex and multilayered performance dynamic, articulating ways o...

  15. Analysis of body surface radiological contamination for inbound people from Japan to China during the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yuan Long; Ma Weidong; Lei Cuiping; Chen Huifang; Li Yuwen; Liu Ying

    2012-01-01

    Objective: To investigate the radiological contamination of body surface for inbound people from Japan to China during Fukushima nuclear accident. Methods: According to The guidance for radiological contamination management for body surface issued by Chinese Center for Disease Control and Prevention, for people evacuated from Japan, the body surface monitoring of radiological contamination was performed by the related agencies in main provinces and cities in China. The monitoring data were collected, analyzed and reported to Ministry of Health. Results: A total of 432 persons were checked. The monitoring results of 429 cases were close to the background level, while those of three persons were higher than the background level. Conclusions: In general,the detected results were as low as the background level. The radiological contamination monitoring of body surface for people from Japan could provide scientific data to relax the horror and panic among them. (authors)

  16. 324 Building Baseline Radiological Characterization

    International Nuclear Information System (INIS)

    Reeder, R.J.; Cooper, J.C.

    2010-01-01

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building. A total of 85 technical (100 square centimeter (cm 2 )) smears were collected from the Room 147 hoods, the Shielded Materials Facility (SMF), and the Radiochemical Engineering Cells (REC). Exposure rate readings (window open and window closed) were taken at a distance of 2.5 centimeters (cm) and 30 cm from the surface of each smear. Gross beta-gamma and alpha counts of each smear were also performed. The smear samples were analyzed by gamma energy analysis (GEA). Alpha energy analysis (AEA) and strontium-90 analysis were also performed on selected smears. GEA results for one or more samples reported the presence of manganese-54, cobalt-60, silver-108m antimony-125, cesium-134, cesium-137, europium-154, europium-155, and americium-241. AEA results reported the presence of plutonium-239/240, plutonium-238/ 241 Am, curium-243/244, curium-242, and americium-243. Tables 5 through 9 present a summary by location of the estimated maximum removable and total contamination levels in the Room 147 hoods, the SMF, and the REC. The smear sample survey data and laboratory analytical results are presented in tabular form by sample in Appendix A. The Appendix A tables combine survey data documented in radiological survey reports found in Appendix B and laboratory analytical results reported in the 324 Building Physical and Radiological Characterization Study (Berk, Hill, and Landsman 1998), supplemented by the laboratory analytical results found in Appendix C.

  17. Radiological emergency preparedness (REP) program

    International Nuclear Information System (INIS)

    Kwiatkowski, D.H.

    1995-01-01

    This talk focuses on the accomplishments of Radiological Emergency Preparedness Program. Major topics include the following: strengthening the partnership between FEMA, the States, and the Industry; the Standard Exercise Report Format (SERF); Multi-year performance partnership agreement (MYPPA); new REP Program guidance; comprehensive exercise program; federal radiological emergency response plan (FRERP); international interest; REP user fee; implementation EPA PAGs and Dose Limits; Contamination monitoring standard for portal monitors; guidance documents and training

  18. The establishment of computer codes for radiological assessment on LLW final disposal in Taiwan

    International Nuclear Information System (INIS)

    Yang, C.C.; Chen, H.T.; Shih, C.L.; Yeh, C.S.; Tsai, C.M.

    1988-01-01

    For final shallow land disposal of Low Level Waste (LLW) in Taiwan, an effort was initiated to establish the evaluation codes for the needs of environmental impact analysis. The objective of the computer code is to set up generic radiological standards for future evaluation on 10 CFR Part 61 Licensing Requirements for Land Disposal of Radioactive Wastes. In determining long-term influences resulting from radiological impacts of LLW at disposal sites there are at least three quantifiable impact measures selected for calculation: dose to members of the public (individual and population), occupational exposures and costs. The computer codes are from INTRUDE, INVERSI and INVERSW of NUREG-0782, OPTIONR and GRWATRR of NUREG-0945. They are both installed in FACOM-M200 and IBM PC/AT systems of Institute of Nuclear Energy Research (INER). The systematic analysis of the computer codes depends not only on the data bases supported by NUREG/CR-1759 - Data Base for Radioactive Waste Management, Volume 3, Impact Analysis Methodology Report but also the information collected from the different exposure scenarios and pathways. The sensitivity study is also performed to assure the long-term stability and security for needs of determining performance objectives

  19. Evidence-based Practice of Radiology.

    Science.gov (United States)

    Lavelle, Lisa P; Dunne, Ruth M; Carroll, Anne G; Malone, Dermot E

    2015-10-01

    Current health care reform in the United States is producing a shift in radiology practice from the traditional volume-based role of performing and interpreting a large number of examinations to providing a more affordable and higher-quality service centered on patient outcomes, which is described as a value-based approach to the provision of health care services. In the 1990 s, evidence-based medicine was defined as the integration of current best evidence with clinical expertise and patient values. When these methods are applied outside internal medicine, the process is called evidence-based practice (EBP). EBP facilitates understanding, interpretation, and application of the best current evidence into radiology practice, which optimizes patient care. It has been incorporated into "Practice-based Learning and Improvement" and "Systems-based Practice," which are two of the six core resident competencies of the Accreditation Council for Graduate Medical Education and two of the 12 American Board of Radiology milestones for diagnostic radiology. Noninterpretive skills, such as systems-based practice, are also formally assessed in the "Quality and Safety" section of the American Board of Radiology Core and Certifying examinations. This article describes (a) the EBP framework, with particular focus on its relevance to the American Board of Radiology certification and maintenance of certification curricula; (b) how EBP can be integrated into a residency program; and (c) the current value and likely place of EBP in the radiology information technology infrastructure. Online supplemental material is available for this article. © RSNA, 2015.

  20. Knowledge transfer objects and innovation performance

    DEFF Research Database (Denmark)

    Sajadirad, Solmaz; Lassen, Astrid Heidemann

    2016-01-01

    Local knowledge of globally distributed subsidiaries may be a valuable source of innovation for headquarters. However, acquiring local knowledge of subsidiaries and transforming it into innovation performance remains a challenge for many multinational companies. In this paper, based on analysis...... of eleven multinational companies present in Danish industry, we characterize different approaches to the use of knowledge transfer objects (static vs. dynamic), and discuss the respective effect on innovation performance. A conceptual framework is proposed to classify such different approaches on the basis...

  1. Digital panoramic radiograph rejection index at a Dental Radiology Service in Paraná, Brazil

    International Nuclear Information System (INIS)

    Mickus, J.; Barros, F.S.; Sato, G.Y.; Rosa, P.C.

    2017-01-01

    Panoramic radiography is the most frequent extraoral examination in dentistry. This technique allows the visualization of adjacent maxillomandibular and anatomical structures. Although digital imaging systems are already the great majority of dental radiology services, there is still a shortage of works evaluating the quality of this type of image. The objective of this study was to identify the rejection index of digital panoramic radiographs of a dental radiology service of a university in Brazil, pointing out the main reasons. A survey was performed on the image files and, randomly selected, 2306 images, 10% of the examinations performed in the period between 2013 to 2015. The results indicated a total rejection rate of 5.1% over the three years, totaling 117 radiographs. The main reasons for rejection were: the patient's head tilted backwards in 2013 and the lack of tongue contact with the palate, for the years 2014 and 2015. The main reasons for repetition of exams are related to the positioning in the execution of the technique radiological factors, which may be related to the lack of professional training. Patient collaboration during the examination and professional-to-patient communication failures may result in poor diagnostic quality exams

  2. How visual search relates to visual diagnostic performance : a narrative systematic review of eye-tracking research in radiology

    NARCIS (Netherlands)

    van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; ten Cate, Olle

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review

  3. A Performance Weighted Collaborative Filtering algorithm for personalized radiology education.

    Science.gov (United States)

    Lin, Hongli; Yang, Xuedong; Wang, Weisheng; Luo, Jiawei

    2014-10-01

    Devising an accurate prediction algorithm that can predict the difficulty level of cases for individuals and then selects suitable cases for them is essential to the development of a personalized training system. In this paper, we propose a novel approach, called Performance Weighted Collaborative Filtering (PWCF), to predict the difficulty level of each case for individuals. The main idea of PWCF is to assign an optimal weight to each rating used for predicting the difficulty level of a target case for a trainee, rather than using an equal weight for all ratings as in traditional collaborative filtering methods. The assigned weight is a function of the performance level of the trainee at which the rating was made. The PWCF method and the traditional method are compared using two datasets. The experimental data are then evaluated by means of the MAE metric. Our experimental results show that PWCF outperforms the traditional methods by 8.12% and 17.05%, respectively, over the two datasets, in terms of prediction precision. This suggests that PWCF is a viable method for the development of personalized training systems in radiology education. Copyright © 2014. Published by Elsevier Inc.

  4. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  5. Radiation protection in medical diagnostic radiology in the city of Sobral, Brazil

    International Nuclear Information System (INIS)

    Menezes, F.L.; Paschoal, C.M.M.; Ferreira, F.C.L.; Alcantara, M.C.

    2015-01-01

    The objective of this study was to evaluate the suitability to radiation protection of four diagnostic radiology medical services in the city of Sobral-CE, Northeast of Brazil, and to analyze results of the literature for the cities of Rio Branco-AC, North of Brazil, and Rio de Janeiro-RJ, South-east of Brazil. In Sobral-CE, it was performed interviews and direct observations with reference to Brazilian law, the National Ordinance No.453/1998 of the Ministry of Health that regulates the operation of medical and odontological diagnostic radiology services. The results show the occurrence of many items in disagreement with the standard. The technical and operational infractions have basically due to unfamiliarity with the legislation, the lack of investment in training and/or professional development courses. (authors)

  6. Dosimetry in diagnosis examinations in radiology

    International Nuclear Information System (INIS)

    Lisbona, Albert; Aubert, Bernard; Laffont, Sophie; Beaumont, Stephane; Catala, Alexandre; Cohard, Cecile; Cordoliani, Yves-Sebastien; Giraud, Jean-Yves; Lescrainier, Jacques; Noel, Alain; Verdun, Francis R.

    2003-01-01

    This document aims at helping the professionals involved in radiology when assessing the delivered doses to patients during conventional radiology examinations, in mammography and scanography. The first part recalls all the dosimetric data susceptible to characterize the X ray beam, the patient exposure and the radiological risk. The second part addresses the different types of sensors which can be used to obtain the different measurable dosimetric values. The third part presents the calculation, analytical and numerical methods. The fourth part proposes a set of sheets of data to be acquired on an installation to perform a measurement and/or a dose calculation

  7. Organizational decentralization in radiology.

    Science.gov (United States)

    Aas, I H Monrad

    2006-01-01

    At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.

  8. Integrative teaching in radiology - a survey.

    Science.gov (United States)

    Dettmer, S; Weidemann, J; Fischer, V; Wacker, F K

    2015-04-01

    To survey integrative teaching in radiology at German universities. A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. The survey was considered representative with a return rate of 68 %. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called "Modellstudiengängen" [model courses of study] (100 %) compared to conventional courses of study (72 %). The advantages of integrative teaching include linking of content (92 %) and preparation for interdisciplinary work (76 %). The disadvantages include high effort (75 %) and time (67 %) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84 %) compared to integrative courses (76 %). Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology. Both integrative teaching and conventional radiological teaching are highly accepted. The advantages include the linking of multidisciplinary content and the preparation for interdisciplinary cooperation

  9. Performance of a Machine Learning Classifier of Knee MRI Reports in Two Large Academic Radiology Practices: A Tool to Estimate Diagnostic Yield.

    Science.gov (United States)

    Hassanpour, Saeed; Langlotz, Curtis P; Amrhein, Timothy J; Befera, Nicholas T; Lungren, Matthew P

    2017-04-01

    The purpose of this study is to evaluate the performance of a natural language processing (NLP) system in classifying a database of free-text knee MRI reports at two separate academic radiology practices. An NLP system that uses terms and patterns in manually classified narrative knee MRI reports was constructed. The NLP system was trained and tested on expert-classified knee MRI reports from two major health care organizations. Radiology reports were modeled in the training set as vectors, and a support vector machine framework was used to train the classifier. A separate test set from each organization was used to evaluate the performance of the system. We evaluated the performance of the system both within and across organizations. Standard evaluation metrics, such as accuracy, precision, recall, and F1 score (i.e., the weighted average of the precision and recall), and their respective 95% CIs were used to measure the efficacy of our classification system. The accuracy for radiology reports that belonged to the model's clinically significant concept classes after training data from the same institution was good, yielding an F1 score greater than 90% (95% CI, 84.6-97.3%). Performance of the classifier on cross-institutional application without institution-specific training data yielded F1 scores of 77.6% (95% CI, 69.5-85.7%) and 90.2% (95% CI, 84.5-95.9%) at the two organizations studied. The results show excellent accuracy by the NLP machine learning classifier in classifying free-text knee MRI reports, supporting the institution-independent reproducibility of knee MRI report classification. Furthermore, the machine learning classifier performed well on free-text knee MRI reports from another institution. These data support the feasibility of multiinstitutional classification of radiologic imaging text reports with a single machine learning classifier without requiring institution-specific training data.

  10. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  11. Development of radiology in Mongolia

    International Nuclear Information System (INIS)

    Gonchigsuren, D.; Munkhbaatar, D.; Tuvshinjargal, D.; Onkhuudai, P.

    2007-01-01

    Full text: Radiology had been introduced in Mongolia by the establishment of the first X-Ray room at the First State Central Hospital in 1934. First radiologists in Mongolia were invited from the former Soviet Union; V. Sokolov, P. Omelchenko and others worked at the ''Burevestnik'' X-ray equipment of Russian production with high X-ray exposure and low capacity; they could perform only limited arts of Xray studies like fluoroscopy of thorax, stomach, esophagus and roentgenography of skull and extremities. The second X- ray equipment has been presented by the close friend of Lenin, the Director of People's Commissariat of Health Protection of the Soviet Union, Dr. N.A. Semashko; the present had been dedicated to the 10th Anniversary of Mongolian Health Care sector. During the military maneuvers at Khalkhin- Gol in 1939, several province hospitals and military hospitals had been supplied by the Xray equipment. During the period 1959-1960 all province hospitals, specialized hospitals had got X-ray unit. In 1955, Radii 226 had been used at first time in Mongolia for a treatment. In 1959, the State Radiological Clinic had been founded as a branch of X-ray cabinet of the First State Central Hospital. By the initiative of the absolvent of University of Leipzig, German Democratic Republic, Dr. P. Onkhuudai, Laboratory of Nuclear Medicine was established on 31 PstP March 1975 at the First State Central Hospital, which performed urography, thyroid and liver studies using Iod-131, Au-198, Hg-203 isotopes. In 1982, the gamma-camera and radio immunological equipment had been donated by the World Health Organization, and the Laboratory of Nuclear Medicine had been reorganized into Department of Nuclear Laboratory. Afterwards, in 1992 CT and SPECT diagnostics had been introduced at the First State Central Hospital, therefore new possibilities for high quality radiological diagnostic in Mongolia had been created. In 2007 the Siemens Magnetom 0.3 Tesla had been installed at the

  12. Machine Learning in Radiology: Applications Beyond Image Interpretation.

    Science.gov (United States)

    Lakhani, Paras; Prater, Adam B; Hutson, R Kent; Andriole, Kathy P; Dreyer, Keith J; Morey, Jose; Prevedello, Luciano M; Clark, Toshi J; Geis, J Raymond; Itri, Jason N; Hawkins, C Matthew

    2018-02-01

    Much attention has been given to machine learning and its perceived impact in radiology, particularly in light of recent success with image classification in international competitions. However, machine learning is likely to impact radiology outside of image interpretation long before a fully functional "machine radiologist" is implemented in practice. Here, we describe an overview of machine learning, its application to radiology and other domains, and many cases of use that do not involve image interpretation. We hope that better understanding of these potential applications will help radiology practices prepare for the future and realize performance improvement and efficiency gains. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  14. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    Science.gov (United States)

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-01-09

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  15. Radiologic discussion on Klebsiella pneumonia in 89 cases

    International Nuclear Information System (INIS)

    Zhang Chunsheng; Li Xuejun; Tai Hanzhen; Wang Guohua; Qi Shi

    2007-01-01

    Objective: To evaluate the diagnostic value of radiology and CT scanning in Klebsiella pneumoniae. Methods: The clinical, radiologic data and CT films of 89 patients with Klebsiella pneumoniae were retrospectively analyzed. Results: Three types of chest X-ray and computed tomography (CT) findings for Klebsiella pneumonia were found. (1)Increased pulmonary markings occured in 31 cases. (2)35 cases with single lesions showed frequently involvement in the upper or lower lobe of right lung. When lesion was involved in the upper lobe, it developed oblique fissure shift down in radiology films and represent stalactitic symptom in CT imagining. (3)In 23 cases with Klebsiella pneumonia showed typical cavitary lung abscesses. Conclusion: The radiologic findings of Klebsiella pneumoniae were complicated and hard to make a good diagnosis. Combined the imaging features with the clinic data, sometimes, we can get the right diagnosis in some cases with typical Klebsiella pneumoniae. (authors)

  16. Job Aids for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, Brooke R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haynes, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wood-Zika, Annmarie R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Klemic, Gladys [US Department of Homeland Security National Urban

    2017-10-02

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation.

  17. Radiological Protection Plan an ethic responsibility

    International Nuclear Information System (INIS)

    Huhn, Andrea; Vargas, Mara Ambrosina de Oliveira

    2014-01-01

    The Radiological Protection Plan - PPR, quoted by the Regulatory Standard 32, requires to be maintained at the workplace and at the disposal of the worker's inspection the PPR, for it to be aware of their work environment and the damage that can be caused by misuse of ionizing radiation. Objective: to discuss the interface between PPR and ethical reflection. Method: this is a reflective study. Discussion and results: regulatory norm 32 points out that the worker who conducts activities in areas where there are sources of ionizing radiation should know the risks associated with their work. However, it is considered that the sectors of hospital radiology the multidisciplinary health team is exposed to ionizing radiation and has not always aware of the harm caused by it, so end up unprotected conduct their activities. Concomitantly, recent studies emphasize the radiological protection and concern for the dangers of radiation on humans, but rather refer to the legislation about the radiological protection. In this context an ethical reflection is necessary, seeking to combine work ethics liability to care in protecting themselves and the other with the institutional conditions for this protection becomes effective

  18. Radiation Protection Knowledge, Attitude, and Practice (KAP in Interventional Radiology

    Directory of Open Access Journals (Sweden)

    Fatemeh Shabani

    2018-03-01

    Full Text Available Objectives: Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP level of radiation protection (RP among interventional radiology staff in Iranian health care centers across the country. Methods: We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician. The questionnaire was divided into three sections to assess KAP regarding RP. Results: Significant differences exist in RP KAP mean scores based on educational age (p 0.050. We found a significant difference between RP KAP mean scores and different regions (p < 0.050. Conclusions: Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments.

  19. The American Board of Radiology perspective on maintenance of certification: Part IV: Practice quality improvement in radiologic physics

    International Nuclear Information System (INIS)

    Frey, G. Donald; Ibbott, Geoffrey S.; Morin, Richard L.; Paliwal, Bhudatt R.; Thomas, Stephen R.; Bosma, Jennifer

    2007-01-01

    Recent initiatives of the American Board of Medical Specialties (ABMS) in the area of maintenance of certification (MOC) have been reflective of the response of the medical community to address public concerns regarding quality of care, medical error reduction, and patient safety. In March 2000, the 24 member boards of the ABMS representing all medical subspecialties in the USA agreed to initiate specialty-specific maintenance of certification (MOC) programs. The American Board of Radiology (ABR) MOC program for diagnostic radiology, radiation oncology, and radiologic physics has been developed, approved by the ABMS, and initiated with full implementation for all three disciplines beginning in 2007. The overriding objective of MOC is to improve the quality of health care through diplomate-initiated learning and quality improvement. The four component parts to the MOC process are: Part I: Professional standing, Part II: Evidence of life long learning and periodic self-assessment, Part III: Cognitive expertise, and Part IV: Evaluation of performance in practice (with the latter being the focus of this paper). The key components of Part IV require a physicist-based response to demonstrate commitment to practice quality improvement (PQI) and progress in continuing individual competence in practice. Diplomates of radiologic physics must select a project to be completed over the ten-year cycle that potentially can improve the quality of the diplomate's individual or systems practice and enhance the quality of care. Five categories have been created from which an individual radiologic physics diplomate can select one required PQI project: (1) Safety for patients, employees, and the public, (2) accuracy of analyses and calculations, (3) report turnaround time and communication issues, (4) practice guidelines and technical standards, and (5) surveys (including peer review of self-assessment reports). Each diplomate may select a project appropriate for an individual

  20. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  1. Optimal layout of radiological environment monitoring based on TOPSIS method

    International Nuclear Information System (INIS)

    Li Sufen; Zhou Chunlin

    2006-01-01

    TOPSIS is a method for multi-objective-decision-making, which can be applied to comprehensive assessment of environmental quality. This paper adopts it to get the optimal layout of radiological environment monitoring, it is proved that this method is a correct, simple and convenient, practical one, and beneficial to supervision departments to scientifically and reasonably layout Radiological Environment monitoring sites. (authors)

  2. The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics

    International Nuclear Information System (INIS)

    Thomas, Stephen R.; Hendee, William R.; Paliwal, Bhudatt R.

    2005-01-01

    Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year, time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice

  3. Performance Evaluation of Java Based Object Relational Mapping Tools

    Directory of Open Access Journals (Sweden)

    Shoaib Mahmood Bhatti

    2013-04-01

    Full Text Available Object persistency is the hot issue in the form of ORM (Object Relational Mapping tools in industry as developers use these tools during software development. This paper presents the performance evaluation of Java based ORM tools. For this purpose, Hibernate, Ebean and TopLinkhave been selected as the ORM tools which are popular and open source. Their performance has been measured from execution point of view. The results show that ORM tools are the good option for the developers considering the system throughput in shorter setbacks and they can be used efficiently and effectively for performing mapping of the objects into the relational dominated world of database, thus creating a hope for a better and well dominated future of this technology.

  4. Incorporating intelligence into structured radiology reports

    Science.gov (United States)

    Kahn, Charles E.

    2014-03-01

    The new standard for radiology reporting templates being developed through the Integrating the Healthcare Enterprise (IHE) and DICOM organizations defines the storage and exchange of reporting templates as Hypertext Markup Language version 5 (HTML5) documents. The use of HTML5 enables the incorporation of "dynamic HTML," in which documents can be altered in response to their content. HTML5 documents can employ JavaScript, the HTML Document Object Model (DOM), and external web services to create intelligent reporting templates. Several reporting templates were created to demonstrate the use of scripts to perform in-template calculations and decision support. For example, a template for adrenal CT was created to compute contrast washout percentage from input values of precontrast, dynamic postcontrast, and delayed adrenal nodule attenuation values; the washout value can used to classify an adrenal nodule as a benign cortical adenoma. Dynamic templates were developed to compute volumes and apply diagnostic criteria, such as those for determination of internal carotid artery stenosis. Although reporting systems need not use a web browser to render the templates or their contents, the use of JavaScript creates innumerable opportunities to construct highly sophisticated HTML5 reporting templates. This report demonstrates the ability to incorporate dynamic content to enhance the use of radiology reporting templates.

  5. [Radiologic picture of maxillary sinus aspergilloma].

    Science.gov (United States)

    Kaczmarek, I; Bilska, J; Osmola, K; Nowaczyk, M T

    2010-06-01

    Mycotic infection of paranasal sinus could be the etiological factor of chronic sinusitis. The increase in number of fungal sinusitis cases have been reported recently among nonimmunocompromised patient after endodontic treatment of maxillary teeth. Nonspecific clinical signs and incorrect radiologic pictures interpretation as well as loss of therapeutic standards seems to be the cause of false negative diagnosis and difficulties in treatment of fungal sinusitis. Clinical and radiological picture of maxillary sinus aspergillosis was described in this paper. In the period of 2006-2009 in the Department of Maxillo-Facial Surgery 19 patient with fungal maxillary sinusitis was treated. The endodontic treatment of maxillary teeth of the related side was performed previously in 80% examined cases. In 2 cases there were immunocompromised patients with immunosuppressive treatment. In 16 cases patients were referred to our Department due to metallic foreign body of the maxillary sinus. Routine diagnostic radiological imaging was performed in each case: paranasal sinus view--Water's view and panoramic radiograph (orthopantomograph). In 4 cases imaging was extended with computer tomography (CT) visualization. The surgical treatment was performed in each case. The final diagnosis was puted on histopathological examination and fungal culture. In 16 cases of analysed group histopathological examination and fungal culture revealed aspergilosis. In 2 cases fungal culture was negative, but histopathology slices confirm presence of hyphae of Aspergillus. In 1 case the root canal sealer was found in the maxillary sinus. In none case invasive form of aspergillosis was confirmed. In all cases Water's view of paranasal sinuses and ortopantomograph showed partially or totally clouded sinus with well-defined, single or multifocal radiopaque object similar to metallic foreign body. Characteristic finding in CT imaging was well-defined radiodence concretions that have been attributed to

  6. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  7. Arthritis: Conventional and Advanced Radiological Imaging

    Directory of Open Access Journals (Sweden)

    Adviye Ergun

    2014-06-01

    Full Text Available Arthritides are acute or chronic inflammation of one or more joints. The most common types of arthritis are osteoarthritis and rheumatoid arthritis, but there are more than 100 different forms. Right and early diagnosis is extremely important for the prevention of eventual structural and functional disability of the affected joint. Imaging findings, especially those of advanced level imaging, play a major role in diagnosis and monitor the progression of arthritis or its response to therapy. The objective of the review is to discuss the findings of conventional and advanced radiological imaging of most common arthritides and to present a simplified approach for their radiological evaluation.

  8. Interventional radiology in cardiov ascular division of radiology department S.N.U hospital{sub s}taff roles and departmental management

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Chul; Cheung, Hwan [Seoul National University Hospital, Seoul (Korea, Republic of)

    1986-11-15

    As the angiography in the field of radiological sciences is being increasingly diversified in its techniques, clinical applications of interventional radiology are rapidly increasing not only for its usefulness in simple diagnosis but for its capabilities of affording, by means of radiological surveillance, biological data such as those concerning tissues which are even substitutionary or supplementary to treatment of diseases. During the last 5 years from July 1980 to 1984 such applications in the cardiovascular division showed a trend of radical increase and thus emerging as a new domain of radiological medicine which has vast influence on diagnosis and treatment. The present treatise presents the results of research performed on the following: 1) Need for close coordination among physicians, radiologists, and nurses in the radiology department. 2) Need for prior explanation to the patient of the procedure to be followed to relieve his anxiety. 3) Checking of the angiographic equipment and selection of technical factors. 4) Proper management of manpower including medical radiologists and assistant radiologists. 5) Sterilization of auxiliary equipment required for surgical operation. 6) Selection of a catheter and control of clinical materials such as contrast agents. 7) Supplementary arrangements for speedy performance of clinical services.

  9. Radiological response of ceramic and polymeric devices for breast brachytherapy

    International Nuclear Information System (INIS)

    Batista Nogueira, Luciana; Passos Ribeiro de Campos, Tarcisio

    2012-01-01

    In the present study, the radiological visibility of ceramic and polymeric devices implanted in breast phantom was investigated for future applications in brachytherapy. The main goal was to determine the radiological viability of ceramic and polymeric devices in vitro by performing simple radiological diagnostic methods such as conventional X-ray analysis and mammography due to its easy access to the population. The radiological response of ceramic and polymeric devices implanted in breast phantom was determined using conventional X-ray, mammography and CT analysis. - Highlights: ► Radiological visibility of ceramic and polymeric devices implanted in breast phantom. ► The barium incorporation in the seed improves the radiological contrast. ► Radiological monitoring shows the position, orientation and degradation of devices. ► Simple radiological methods such as X-ray and mammography were used for radiological monitoring.

  10. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  11. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  12. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  13. Anesthesia for interventional radiology

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.

    1989-01-01

    We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures

  14. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  15. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  16. Subjective and objective performance assessment : Performance pay at Trelleborg Forsheda AB

    OpenAIRE

    Luotonen, David; Hasselström, Markus

    2009-01-01

      The purpose of this thesis is to understand the opinions and potential effects of objective and subjective assessments of performance as a basis for performance pay for blue-collar workers. The study takes a qualitative approach to find out how and why four companies - Trelleborg Forsheda, Finnveden Powertrain, Isaberg Rapid and Parker Hannifin- work with salaries, incentive system and performance assessment the way they do. The concept of individual salary is central in this thesis, and in...

  17. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  18. Assessment of the radiological quality of tap waters 2008-2009

    International Nuclear Information System (INIS)

    Caamano, Delphine; Tracol, Raphael; Guillotin, Laetitia; Jedor, Beatrice; Davezac, Henri; Loyen, Jeanne

    2011-06-01

    After a recall of the context (radioactivity, origin of natural radioactivity in waters, exposure of population to natural radioactivity and health impact, indicators of water radiological quality, presence of uranium in water), this document reports a study which is based on the health control of water radiological quality by regional health agencies, on the analysis of natural and artificial radionuclides, on a survey on tap water radiological quality performed in 2009 by regional health agencies, and on an inventory of results related to the presence of radon in water performed by the IRSN and these agencies. The obtained results are presented and discussed in terms of factors impacting the result representativeness, of generalisation of the implementation of a health control, of tap water radiological quality. It is outlined that the uranium-related chemical risk is higher than the radiological risk

  19. Design and Implementation of High-Performance GIS Dynamic Objects Rendering Engine

    Science.gov (United States)

    Zhong, Y.; Wang, S.; Li, R.; Yun, W.; Song, G.

    2017-12-01

    Spatio-temporal dynamic visualization is more vivid than static visualization. It important to use dynamic visualization techniques to reveal the variation process and trend vividly and comprehensively for the geographical phenomenon. To deal with challenges caused by dynamic visualization of both 2D and 3D spatial dynamic targets, especially for different spatial data types require high-performance GIS dynamic objects rendering engine. The main approach for improving the rendering engine with vast dynamic targets relies on key technologies of high-performance GIS, including memory computing, parallel computing, GPU computing and high-performance algorisms. In this study, high-performance GIS dynamic objects rendering engine is designed and implemented for solving the problem based on hybrid accelerative techniques. The high-performance GIS rendering engine contains GPU computing, OpenGL technology, and high-performance algorism with the advantage of 64-bit memory computing. It processes 2D, 3D dynamic target data efficiently and runs smoothly with vast dynamic target data. The prototype system of high-performance GIS dynamic objects rendering engine is developed based SuperMap GIS iObjects. The experiments are designed for large-scale spatial data visualization, the results showed that the high-performance GIS dynamic objects rendering engine have the advantage of high performance. Rendering two-dimensional and three-dimensional dynamic objects achieve 20 times faster on GPU than on CPU.

  20. Commercial and Advertising Art. Performance Objectives. Basic Course.

    Science.gov (United States)

    Atkinson, Floyd

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 12 terminal objectives for a basic commercial and advertising art course. The materials were developed for a two-semester (2 hours daily) course to enable tenth, eleventh, and twelfth grade students to develop competencies in the care and use of…

  1. Enhancement of radiological protection through an internal quality assessment cycle

    International Nuclear Information System (INIS)

    Figueiredo, Filipe Morais de; Gama, Zenewton Andre da Silva

    2012-01-01

    Objective: To determine the level of quality in radiation protection of patients during radiological examination, evaluating the effectiveness of an intervention aimed at enhancing the quality of such a protection. Materials and Methods: A quality improvement cycle was implemented in a radiology service of the Regional Health Administration, in Algarve, Portugal. Based on six quality criteria, an initial evaluation was performed and followed by an intervention focused on the most problematic points (over an eight-month period) and a subsequent quality reassessment. A random sampling (n = 60) has allowed the authors to infer the point estimates and confidence intervals for each criterion, as well as calculating the statistical significance of the results by means of the Z-test. Results: Initially, deficiencies were observed in relation to all the quality criteria. After the intervention, a minimum relative improvement of 33% was observed in five of the six criteria, with statistical significance (p < 0.05) in two of them. The absolute frequency of noncompliance decreased from 38 (first evaluation) to 21 (second evaluation), corresponding to a 44.7% improvement. Conclusion: The first institutional evaluation cycle showed a seemingly incipient improvement margin. However, the implemented intervention was effective in stimulating good practices and improving the level of radiological protection of patients. (author)

  2. [Marketing mix in a radiology department: challenges for future radiologists in management].

    Science.gov (United States)

    Claikens, B

    1998-08-01

    Radiology has gained an enviable position among medial specialities. Developments in new technology expand its horizons and the volume of radiologic imaging techniques and procedures increase far more than the overall growth in health care services. In this position radiology has become a prime target for restrictions, cutbacks, controlled financing in an area of managed care and new national health care policy based on partially fixed budgets. Future health care takers have to choose the best available diagnostic and therapeutic techniques. Evidence based medicine, cost-utility analysis, diagnostic performance analysis, patient outcome analysis, technology assessment and guidelines for practice are means to guide us through our obligatory choice. Our major objective is to use the most performant available imaging technique or intervention to achieve the best possible outcome for our patient at lower possible costs. A strategic response from radiologists is required to meet the imperatives of this new management situation. They must do far more than interpret imaging procedures. They must work as efficient managers of imaging resources, organise their practices and define their marketing-strategies using the different, so-called, marketing-mix elements. The challenges will be great but the rewards are worth our best efforts. In this article we highlight the marketing responsibilities of future radiologists and their clinical practice in this new socio-economic environment and we present different useful marketing tools.

  3. Soils radiological characterization under a nuclear facility - 59046

    International Nuclear Information System (INIS)

    Aubonnet, Emilie; Dubot, Didier

    2012-01-01

    Nowadays, nuclear industry is facing a crucial need in establishing radiological characterization for the appraisal and the monitoring of any remediation work. Regarding its experience in this domain, the French Alternative Energies and Atomic Energy Commission (CEA) of Fontenay-aux- Roses, established an important feedback and developed over the last 10 years a sound methodology for radiological characterization. This approach is based on several steps: - historical investigations; - assumption and confirmation of the contamination; - surface characterization; - in-depth characterization; - rehabilitation objectives; - remediation process. The amount of measures, samples and analysis is optimized for data processing using geo-statistics. This approach is now used to characterize soils under facilities. The paper presents the radiological characterization of soils under a facility basement. This facility has been built after the first generation of nuclear facilities, replacing a plutonium facility which has been dismantled in 1960. The presentation details the different steps of radiological characterization from historical investigations to optimization of excavation depths, impact studies and contaminated volumes. (authors)

  4. Radiological findings in Wolfram syndrome

    International Nuclear Information System (INIS)

    Hadidy, Azmy M.; Jarrah, Nadim S.; Al-Till, Maha I.; Ajlouni, Kamal M.; El-Shanti, Haten E.

    2004-01-01

    To determine the precise radiologic findings in Wolfram syndrome (WFS) patients using objective techniques in order to better define the reference population for the clinicl evaluation. 16 patients (6 males, 10 female) with WFS found in 4 families were included in this study.14 patients with WFS-2 came from 3 families while 2 patients with EFS-1 came from one family. All patients were studied at Jordan University Hospital, Amman,Jordan from January 2001 to January 2003 by definite radiologic techniques as part of a thorough clinical comprehesive assesment. These incclude intravenous urography, abdominal and pelvic ultrasonography, barium meal, upper gastrointestinal endoscopy and magnetic resonance imaging with and without contrasts to the brain and the pituitary glands.5 of the female ptients had a small uterus. Spina bifida was found in 7, hydronephrosis in 9 and hydroureter in 5 patiets. Peptic ulcer was detected in 10 out of 14 available patients and helicobacter pylori in 7 out of 16 patients. Atrophy was detected was detected in all brains, 9 brain stems, 12 cerebellums and 14 optic tracts of all patients. The size of pituitary glands was variable. The particular radiological assesment of the patients with WFS proved that, urinary tract dialtation was detected in WFS-1and WFS-2 patients though all WFS-2 patients.No significant radiologic difference was between patients with WFS-1 and WFS-2. (author)

  5. How Visual Search Relates to Visual Diagnostic Performance: A Narrative Systematic Review of Eye-Tracking Research in Radiology

    Science.gov (United States)

    van der Gijp, A.; Ravesloot, C. J.; Jarodzka, H.; van der Schaaf, M. F.; van der Schaaf, I. C.; van Schaik, J. P.; ten Cate, Th. J.

    2017-01-01

    Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology…

  6. Schatzki ring in children and young adults: clinical and radiologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, K.; Buonomo, C. [Department of Radiology, Children`s Hospital, Boston, MA (United States); Husain, K.; Nurko, S. [Division of Gastroenterology, Children`s Hospital, Boston, MA (United States)

    1998-11-01

    Background. The Schatzki ring is a well-known clinical and radiologic entity in adults, but is thought to be rare in childhood. Objective. To review the clinical presentations and radiologic findings of children and young adults with Schatzki rings. Materials and methods. A retrospective review of all barium swallow examinations done between 1990 and 1996 revealed 20 patients with Schatzki rings. Results. The most frequent presenting symptoms of these patients were progressive dysphagia with solid food and acute food impaction. Radiographic findings of Schatzki rings were typical in all cases. Twelve patients had endoscopy and all had evidence of esophagitis. Conclusion. Schatzki rings are not rare in childhood. The patients are symptomatic, presenting with either progressive dysphagia with solids or acute food impaction. A thorough evaluation of the distal esophagus should be performed in patients with a suggestive clinical history. (orig.) With 2 figs., 8 refs.

  7. Radiological safety and control

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Sea Young; Yoo, Y S; Lee, J C; Lee, T Y; Lee, J L; Kim, B W; Lee, B J; Chung, K K; Chung, R I; Kim, J S; Lee, H S; Han, Y D; Lee, J I; Lee, K C; Yoon, J H; Sul, C W; Kim, C K; Yoon, K S; Seo, K W; Yoon, Y C [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    This report describes the annual results of radiological safety and control program of 1995. This program consists of working area monitoring including HANARO, personnel radiation monitoring, education for radiation protection. As a result, the objectives of radiation protection have been achieved satisfactorily through the activities mentioned above. Also, the calibration services were provided to insure accurate radiation measurement in the radiation working places. 21 figs., 39 tabs., 5 refs. (Author) .new.

  8. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  9. Quality assurance program on diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, Alejandro; Borges, Jose Carlos; Mota, Helvecio Correa

    1995-01-01

    Aiming to elaborate a methodology to optimize the performance of the Radiology Service of the Military Police Hospital, in Rio de Janeiro, some goals were established: improvement of the attendance to patients; improvement of the qualification of technicians; achievement and maintenance of high degrees of quality in each step of the radiological process; improvement of the image quality; optimization of dose per examination and cost reduction. (author). 8 refs., 3 figs

  10. Radiological anatomy - evaluation of integrative education in radiology.

    Science.gov (United States)

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Analysis of the Radiology Reports from Radiology Clinics

    International Nuclear Information System (INIS)

    Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho

    2009-01-01

    The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians

  12. A consequence index approach to identifying radiological sabotage targets

    International Nuclear Information System (INIS)

    Altman, W.D.; Hockert, J.W.

    1988-01-01

    One of the threats to concern to facilities using significant quantities of radioactive material is radiological sabotage. Both the Department of Energy (DOE) and the U.S. Nuclear Regulatory Commission have issued guidance to facilities for radiological sabotage protection. At those facilities where the inventories of radioactive materials change frequently, there is an operational need for a technically defensible method of determining whether or not the inventory of radioactive material at a given facility poses a potential radiological sabotage risk. In order to determine quickly whether a building is a potential radiological sabotage target, Lawrence Livermore National Loaboratory (LLNL) has developed a radiological sabotage consequence index that provides a conservative estimate of the maximum potential off-site consequences of a radiological sabotage attempt involving the facility. This radiological sabotage consequence index can be used by safeguards and security staff to rapidly determine whether a change in building operations poses a potential radiological sabotage risk. In those cases where such a potential risk is identified, a more detailed radiological sabotage vulnerability analysis can be performed

  13. Ambulatory phlebectomy at radiologic outpatient clinic

    International Nuclear Information System (INIS)

    Yoon, Chang Jin; Kang, Sung Gwon; Choi, Sang Il; Lee, Whal; Chung, Jin Wook; Park, Jae Hyung

    2007-01-01

    To evaluate safety, efficacy, and patient's satisfaction of an ambulatory phlebectomy, performed at a radiology outpatient clinic. Between 2003 and 2006, an ambulatory phlebectomy was performed in 12 patients. Endovenous radiofrequency ablation was performed through a venotomy. The venotomy was ligated after RF ablation, and the ambulatory phlebectomy was performed. The patients visited the radiology outpatient clinic one day, one week, and 2 months after the procedure. The improvement in the clinical symptoms, cosmetic change in varicosity, and the procedure related complications were evaluated. The patient's satisfaction was evaluated using a 5-grade scale. RF ablation through a venotomy was performed successfully in all 12 patients. On average, 4.5 incisions were made, and 12.5 cm of varicosity had been removed. The mean procedure time was one hour and forty minutes. The complications of the ambulatory phlebectomy were bruising in one patient, and skin pigmentation in another. The complications associated with RF ablation were a hard palpable vein in 7 patients, numbness in 7 patients, and skin pigmentation along the vein in 2 patients. Follow-up duplex sonography was performed at 2 months after the procedure, showed complete occlusion in all 12 patients. The clinical symptoms had improved in 11 patients, and the varicosity disappeared cosmetically in 11 patients. An ambulatory phlebectomy, combined with RF ablation of the greater saphenous vein, can be performed safely and effectively at a radiology outpatient clinic

  14. Ambulatory phlebectomy at radiologic outpatient clinic

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chang Jin; Kang, Sung Gwon; Choi, Sang Il [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Whal; Chung, Jin Wook; Park, Jae Hyung [Seoul National University, Medical College, Seoul (Korea, Republic of)

    2007-03-15

    To evaluate safety, efficacy, and patient's satisfaction of an ambulatory phlebectomy, performed at a radiology outpatient clinic. Between 2003 and 2006, an ambulatory phlebectomy was performed in 12 patients. Endovenous radiofrequency ablation was performed through a venotomy. The venotomy was ligated after RF ablation, and the ambulatory phlebectomy was performed. The patients visited the radiology outpatient clinic one day, one week, and 2 months after the procedure. The improvement in the clinical symptoms, cosmetic change in varicosity, and the procedure related complications were evaluated. The patient's satisfaction was evaluated using a 5-grade scale. RF ablation through a venotomy was performed successfully in all 12 patients. On average, 4.5 incisions were made, and 12.5 cm of varicosity had been removed. The mean procedure time was one hour and forty minutes. The complications of the ambulatory phlebectomy were bruising in one patient, and skin pigmentation in another. The complications associated with RF ablation were a hard palpable vein in 7 patients, numbness in 7 patients, and skin pigmentation along the vein in 2 patients. Follow-up duplex sonography was performed at 2 months after the procedure, showed complete occlusion in all 12 patients. The clinical symptoms had improved in 11 patients, and the varicosity disappeared cosmetically in 11 patients. An ambulatory phlebectomy, combined with RF ablation of the greater saphenous vein, can be performed safely and effectively at a radiology outpatient clinic.

  15. Synergism in regulation of nuclear and radiological activities

    International Nuclear Information System (INIS)

    Buzdugan, A.

    2009-01-01

    In 2006 the reform of nuclear activity regulation in Moldova was initiated. On May 11, 2006, the Parliament of the Republic of Moldova passed the law Nr 111-XVI 'About Safe Accomplishment of Nuclear and Radiological Activity'. On the 23rd of March, 2007 the National Agency for Regulation of Nuclear and Radiological Activities (NARNRA) was founded due to the decree of the Government under the Ministry of Ecology and Natural Resources. Its first objective was elaboration of necessary regulation documents in this field

  16. Mobile autonomous robot for radiological surveys

    International Nuclear Information System (INIS)

    Dudar, A.M.; Wagner, D.G.; Teese, G.D.

    1992-01-01

    The robotics development group at the Savannah River Laboratory (SRL) is developing a mobile autonomous robot that performs radiological surveys of potentially contaminated floors. The robot is called SIMON, which stands for Semi-Intelligent Mobile Observing Navigator. Certain areas of SRL are classified as radiologically controlled areas (RCAs). In an RCA, radioactive materials are frequently handled by workers, and thus, the potential for contamination is ever present. Current methods used for floor radiological surveying includes labor-intensive manual scanning or random smearing of certain floor locations. An autonomous robot such as SIMON performs the surveying task in a much more efficient manner and will track down contamination before it is contacted by humans. SIMON scans floors at a speed of 1 in./s and stops and alarms upon encountering contamination. Its environment is well defined, consisting of smooth building floors with wide corridors. The kind of contaminations that SIMON is capable of detecting are alpha and beta-gamma. The contamination levels of interest are low to moderate

  17. Cost accounting of radiological examinations. Cost analysis of radiological examinations of intermediate referral hospitals and general practice.

    Science.gov (United States)

    Lääperi, A L

    1996-01-01

    The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and

  18. Smartphone applications in paediatric radiology: availability and authority

    International Nuclear Information System (INIS)

    Shelmerdine, Susan C.; Lynch, Jeremy O.

    2015-01-01

    With the widespread ownership of smartphones, many health care professionals question the degree to which medically related smartphone applications are reliable. To assess the variety of smartphone applications relating to paediatric radiology and the presence of health care professional involvement in their development. As a secondary objective, we explore whether there are gaps within the paediatric radiology app market. The most popular smartphone marketplaces (Apple iTunes App Store, Blackberry Mobile Market, Google Play Android Market, Nokia Ovi, Samsung and Microsoft Windows Marketplace) were searched for terms relating to paediatric radiology. Cost, review ratings, number of downloads, health care involvement and target audience were recorded. Nine paediatric radiology applications were found in the Apple iTunes App Store and nine in the Google Play Android Market. The target audiences for all applications were health care professionals. None were available for patients or their caregivers. All applications were reported to have medical expertise in their development. All paediatric radiology applications were developed with the aid of a health care professional. Due to the small number available online, there is a potential gap in the marketplace for further applications in this field, possibly aimed at patients and their families. (orig.)

  19. Smartphone applications in paediatric radiology: availability and authority

    Energy Technology Data Exchange (ETDEWEB)

    Shelmerdine, Susan C. [Great Ormond Street Hospital, Specialist Registrar in Clinical Radiology, Department of Clinical Radiology, London (United Kingdom); Lynch, Jeremy O. [Chelsea and Westminster Hospital, Specialist Registrar in Clinical Radiology, Department of Clinical Radiology, London (United Kingdom)

    2015-08-15

    With the widespread ownership of smartphones, many health care professionals question the degree to which medically related smartphone applications are reliable. To assess the variety of smartphone applications relating to paediatric radiology and the presence of health care professional involvement in their development. As a secondary objective, we explore whether there are gaps within the paediatric radiology app market. The most popular smartphone marketplaces (Apple iTunes App Store, Blackberry Mobile Market, Google Play Android Market, Nokia Ovi, Samsung and Microsoft Windows Marketplace) were searched for terms relating to paediatric radiology. Cost, review ratings, number of downloads, health care involvement and target audience were recorded. Nine paediatric radiology applications were found in the Apple iTunes App Store and nine in the Google Play Android Market. The target audiences for all applications were health care professionals. None were available for patients or their caregivers. All applications were reported to have medical expertise in their development. All paediatric radiology applications were developed with the aid of a health care professional. Due to the small number available online, there is a potential gap in the marketplace for further applications in this field, possibly aimed at patients and their families. (orig.)

  20. Advanced Neutron Source radiological design criteria

    International Nuclear Information System (INIS)

    Westbrook, J.L.

    1995-08-01

    The operation of the proposed Advanced Neutron Source (ANS) facility will present a variety of radiological protection problems. Because it is desired to design and operate the ANS according to the applicable licensing standards of the Nuclear Regulatory Commission (NRC), it must be demonstrated that the ANS radiological design basis is consistent not only with state and Department of Energy (DOE) and other usual federal regulations, but also, so far as is practicable, with NRC regulations and with recommendations of such organizations as the Institute of Nuclear Power Operations (INPO) and the Electric Power Research Institute (EPRI). Also, the ANS radiological design basis is in general to be consistent with the recommendations of authoritative professional and scientific organizations, specifically the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP). As regards radiological protection, the principal goals of DOE regulations and guidance are to keep occupational doses ALARA [as low as (is) reasonably achievable], given the current state of technology, costs, and operations requirements; to control and monitor contained and released radioactivity during normal operation to keep public doses and releases to the environment ALARA; and to limit doses to workers and the public during accident conditions. Meeting these general design objectives requires that principles of dose reduction and of radioactivity control by employed in the design, operation, modification, and decommissioning of the ANS. The purpose of this document is to provide basic radiological criteria for incorporating these principles into the design of the ANS. Operations, modification, and decommissioning will be covered only as they are affected by design

  1. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    Science.gov (United States)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  2. Introduction of radiological protection; Pengenalan kepada perlindungan radiologi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: basic principles of radiological protection , dose limit which was suggested, stochastic and nonstochastic effects, equivalent dose and alternative of it`s calculation, limit for the publics, ICRP (International Commission for Radiological Protection) recommendations, and the principles of radiological protection. Dangerous radiation sources also briefly summarized i.e. x-ray generators, reactor nucleus.

  3. Assessment of risk in radiology using malpractice RVU

    International Nuclear Information System (INIS)

    Cristofaro, Massimo; Bellandi, Giuseppe; Squarcione, Salvatore; Petecchia, Antonella; Mammarella, Assunta; Bibbolino, Corrado

    2007-01-01

    Introduction: Analysis on the causes and remedies needed to reduce the incidence of malpractice has been under continual studies, although limited data is available regarding quantitative evaluation of the risk. Objectives: To determine radiological risk in a preventive and quantitative manner and verify if the malpractice relative value units (MP-RVU) are a good indicator of associated risk factors. Materials and methods: Radiological examinations executed by our Radiology Department in 2000-2004 have been codified according to nomenclature HCPCS (Healthcare Common Procedure Coding System) used by United States of America Centers for Medicare and Medicaid Services (CMS). For every examination was calculated the annual weight of malpractice. The data has been groupped in macroaggregates by methodology. The ratio MP-RVU/no. examinations has been considered as an index of insurance risk (MP index) Results: A total of 133,005 examinations were performed, which produced 25,252 MP-RVU points, the total mp index was 0.193. Traditional radiology represents 38% of the examinations, accounting for 8% of MP-RVU with a MP index = 0.039. Ultrasound represents 35% of the examinations, accounting for 23% of MP-RVU with a MP index = 0.125. CT represents 13% of the examinations, accounting for 28% of MP-RVU with a MP index = 0.434. MR represents 11% of the examinations, accounting for 39% of MP-RVU with a MP index = 0.667. Conclusions: Malpractice relative value units (MP-RVU) are indicative of the risk considered globally and when subgrouped. MP index correlates this risk with number of exams carried out divided by methodology. This model providing quantitative data for projects concerning risk management and in allowing the correlation between data obtained in different departments

  4. Assessment of risk in radiology using malpractice RVU

    Energy Technology Data Exchange (ETDEWEB)

    Cristofaro, Massimo [U.O. di Diagnostica per Immagini, Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani Via Portuense, 292, 00149 Rome (Italy)]. E-mail: mcristofar@srm.org; Bellandi, Giuseppe [Servizio di Radiologia ASL 3 Ospedale di Pescia, Via Battisti 2, 51017 Pescia (PT) (Italy)]. E-mail: g.bellandi@mail.vdn.usl3.toscana.it; Squarcione, Salvatore [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: squarcione@inmi.it; Petecchia, Antonella [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: petecchia@inmi.it; Mammarella, Assunta [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: mammarella@inmi.it; Bibbolino, Corrado [U.O. di Diagnostica per Immagini, Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani Via Portuense, 292, 00149 Rome (Italy)]. E-mail: bibbolino@inmi.it

    2007-02-15

    Introduction: Analysis on the causes and remedies needed to reduce the incidence of malpractice has been under continual studies, although limited data is available regarding quantitative evaluation of the risk. Objectives: To determine radiological risk in a preventive and quantitative manner and verify if the malpractice relative value units (MP-RVU) are a good indicator of associated risk factors. Materials and methods: Radiological examinations executed by our Radiology Department in 2000-2004 have been codified according to nomenclature HCPCS (Healthcare Common Procedure Coding System) used by United States of America Centers for Medicare and Medicaid Services (CMS). For every examination was calculated the annual weight of malpractice. The data has been groupped in macroaggregates by methodology. The ratio MP-RVU/no. examinations has been considered as an index of insurance risk (MP index) Results: A total of 133,005 examinations were performed, which produced 25,252 MP-RVU points, the total mp index was 0.193. Traditional radiology represents 38% of the examinations, accounting for 8% of MP-RVU with a MP index = 0.039. Ultrasound represents 35% of the examinations, accounting for 23% of MP-RVU with a MP index = 0.125. CT represents 13% of the examinations, accounting for 28% of MP-RVU with a MP index = 0.434. MR represents 11% of the examinations, accounting for 39% of MP-RVU with a MP index = 0.667. Conclusions: Malpractice relative value units (MP-RVU) are indicative of the risk considered globally and when subgrouped. MP index correlates this risk with number of exams carried out divided by methodology. This model providing quantitative data for projects concerning risk management and in allowing the correlation between data obtained in different departments.

  5. TH-E-201-00: Teaching Radiology Residents: What, How, and Expectation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.

  6. TH-E-201-01: Diagnostic Radiology Residents Physics Curriculum and Updates

    Energy Technology Data Exchange (ETDEWEB)

    Sensakovic, W. [Florida Hospital (United States)

    2016-06-15

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.

  7. TH-E-201-00: Teaching Radiology Residents: What, How, and Expectation

    International Nuclear Information System (INIS)

    2016-01-01

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant

  8. TH-E-201-01: Diagnostic Radiology Residents Physics Curriculum and Updates

    International Nuclear Information System (INIS)

    Sensakovic, W.

    2016-01-01

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant

  9. Analysis of radiology education in undergraduate medical doctors training in Europe

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Valcke, Martin; Derese, Anselme; Verstraete, Koenraad L.

    2011-01-01

    Objectives: The purpose of the present study is to describe how undergraduate radiology teaching is organized in Europe and to identify important characteristics of undergraduate radiology curriculum. Methods: An electronic survey on undergraduate teaching was distributed by the European Society of Radiology (ESR) to 38 national delegates of the ESR Education Committee. Results: The 'classic type' of radiology teaching method is more frequent than the 'modular type'. In 38% of medical training centres the first experience with radiology is in pre-clinical years. The students enrolled in the fourth medical year experience the largest involvement in radiology education. The total number of teaching hours (mean 89 h, median 76 h) varies across the countries and differs depending on the radiological topic (mean across all topics 14.8 h, median 13). Written tests and oral exams were the most frequently used examination modes. Clerkships are reported as a key part of training. Conclusion: This first international comparative study of undergraduate radiological curriculum in Europe identifies a large number of differences in curriculum content and teaching methods throughout Europe. More research is needed to establish the radiological educational competences resulting from these differing curricula's to improve and to standardize the teaching according to (inter)national and institutional needs.

  10. Radiological monitoring of food in Cuba

    International Nuclear Information System (INIS)

    Jerez V, S.F.

    1996-01-01

    The appearing of the problem for protecting the environment from radioactive contamination is not an accidental matter. The introduction into the earth crust of radioactive material coming from nuclear weapons, accidents, wastes, etc, has caused, as a consequence, the contamination of the biosphere. The extensive trade of food in our country has made necessary the establishment of radiological monitoring in food, which was organized by the Department of Public Health. The structure, functions, characteristics and aspects related to radiological monitoring of food in Cuba are shown in the present paper. The organization and resources for performing the monitoring program, both for normal conditions and for nuclear and/or radiological emergency cases, are detailed. (author). 12 refs., 2 figs

  11. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  12. Evidence-based radiology: why and how?

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Hunink, Myriam G.; Gilbert, Fiona J.; Krestin, Gabriel P.

    2010-01-01

    To provide an overview of evidence-based medicine (EBM) in relation to radiology and to define a policy for adoption of this principle in the European radiological community. Starting from Sackett's definition of EBM we illustrate the top-down and bottom-up approaches to EBM as well as EBM's limitations. Delayed diffusion and peculiar features of evidence-based radiology (EBR) are defined with emphasis on the need to shift from the demonstration of the increasing ability to see more and better, to the demonstration of a significant change in treatment planning or, at best, of a significant gain in patient outcome. The ''as low as reasonably achievable'' (ALARA) principle is thought as a dimension of EBR while EBR is proposed as part of the core curriculum of radiology residency. Moreover, we describe the process of health technology assessment in radiology with reference to the six-level scale of hierarchy of studies on diagnostic tests, the main sources of bias in studies on diagnostic performance, and levels of evidence and degrees of recommendations according to the Centre for Evidence-Based Medicine (Oxford, UK) as well as the approach proposed by the GRADE working group. Problems and opportunities offered by evidence-based guidelines in radiology are considered. Finally, we suggest nine points to be actioned by the ESR in order to promote EBR. Radiology will benefit greatly from the improvement in practice that will result from adopting this more rigorous approach to all aspects of our work. (orig.)

  13. THE WORK PROCESS IN RADIOLOGICAL NURSING: INVISIBILITY OFIONIZING RADIATION

    OpenAIRE

    Melo,Juliana Almeida Coelho de; Gelbcke,Francine Lima; Huhn,Andrea; Vargas,Mara Ambrosina de Oliveira

    2015-01-01

    ABSTRACT Qualitative descriptive and exploratory research, performed with 20 nursing professionals working in a general radiology unit and surgery center with the "C-arm" equipment, and the hemodynamics unit of a southern Brazilian teaching hospital. Aim was to analyze the dimensions of the work process for radiological technology nurse professionals. This paper made clear that radiological technologies are outside nursing, which leads to the invisibility of ionizing radiation, leading to ina...

  14. Intercomparison Measurements Exercises of Mobile Radiological Laboratories (invited paper)

    International Nuclear Information System (INIS)

    Martincic, R.

    2000-01-01

    After the reactor accident in Chernobyl, the importance of mobile radiological laboratories became evident and in situ gamma spectrometry became a common method for the rapid detection of gamma emitters in the environment. Since then different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the measurement methods and the preparedness of emergency monitoring teams. The general objectives of these workshops are to promote the knowledge and to exchange the experiences of emergency monitoring teams that use mobile radiological laboratories, as well as to foster the international harmonisation of emergency monitoring procedures and cooperation among teams. Finally, the results of intercomparison measurements have shown that such exercises are mandatory for rapid, efficient and correct environmental monitoring in nuclear or radiological emergencies. An overview of these intercomparison measurements is given, results from the 1999 intercomparison workshop are presented and lessons learned are discussed. (author)

  15. A virtual environment for simulation of radiological accidents

    International Nuclear Information System (INIS)

    Silva, Tadeu Augusto de Almeida; Farias, Oscar Luiz Monteiro de

    2013-01-01

    A virtual environment is a computer environment, representative of a subset of the real world, and where models of the real world entities, process and events are included in a virtual (three-dimensional) space. Virtual environments are ideal tools for simulation of certain critical processes, such as radiological accidents, where human beings or properties can suffer irreversible or long term damages. Radiological accidents are characterized by the significant exposure to radiation of specialized workers and general public. The early detection of a radiological accident and the determination of its possible extension are essential factors for the planning of prompt answers and emergency actions. This paper proposes the integration of georeferenced representation of the three-dimensional space and agent-based models, with the objective to construct virtual environments that have the capacity to simulate radiological accidents. The three-dimensional georeferenced representations of space candidates are: 1) the spatial representation of traditional geographical information systems (GIS); 2) the representation adopted by Google Maps®. Adding agents to these spatial representations allow us to simulate radiological accidents, quantify the doses received by members of the public, obtain a possible spatial distribution of people contaminated, estimate the number of contaminated individuals, estimate the impact on the health-network, estimate environmental impacts, generate exclusion zones, build alternative scenarios and train staff to deal with radiological accidents. (author)

  16. A virtual environment for simulation of radiological accidents

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Tadeu Augusto de Almeida, E-mail: tedsilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Farias, Oscar Luiz Monteiro de, E-mail: fariasol@eng.uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    A virtual environment is a computer environment, representative of a subset of the real world, and where models of the real world entities, process and events are included in a virtual (three-dimensional) space. Virtual environments are ideal tools for simulation of certain critical processes, such as radiological accidents, where human beings or properties can suffer irreversible or long term damages. Radiological accidents are characterized by the significant exposure to radiation of specialized workers and general public. The early detection of a radiological accident and the determination of its possible extension are essential factors for the planning of prompt answers and emergency actions. This paper proposes the integration of georeferenced representation of the three-dimensional space and agent-based models, with the objective to construct virtual environments that have the capacity to simulate radiological accidents. The three-dimensional georeferenced representations of space candidates are: 1) the spatial representation of traditional geographical information systems (GIS); 2) the representation adopted by Google Maps®. Adding agents to these spatial representations allow us to simulate radiological accidents, quantify the doses received by members of the public, obtain a possible spatial distribution of people contaminated, estimate the number of contaminated individuals, estimate the impact on the health-network, estimate environmental impacts, generate exclusion zones, build alternative scenarios and train staff to deal with radiological accidents. (author)

  17. Assessing reader performance in radiology, an imperfect science: Lessons from breast screening

    Energy Technology Data Exchange (ETDEWEB)

    Soh, B.P., E-mail: bsoh6456@uni.sydney.edu.au [Medical Image Optimisation and Perception Group (MIOPeG), Faculty of Health Sciences, University of Sydney, Lidcombe, NSW (Australia); Lee, W.; Kench, P.L.; Reed, W.M.; McEntee, M.F.; Poulos, A.; Brennan, P.C. [Medical Image Optimisation and Perception Group (MIOPeG), Faculty of Health Sciences, University of Sydney, Lidcombe, NSW (Australia)

    2012-07-15

    The purpose of this article is to review the limitations associated with current methods of assessing reader accuracy in mammography screening programmes. Clinical audit is commonly used as a quality-assurance tool to monitor the performance of screen readers; however, a number of the metrics employed, such as recall rate as a surrogate for specificity, do not always accurately measure the intended clinical feature. Alternatively, standardized screening test sets, which benefit from ease of application, immediacy of results, and quicker assessment of quality improvement plans, suffer from experimental confounders, thus questioning the relevance of these laboratory-type screening test sets to clinical performance. Four key factors that impact on the external validity of screening test sets were identified: the nature and extent of scrutiny of one's action, the artificiality of the environment, the over-simplification of responses, and prevalence of abnormality. The impact of these factors on radiological and other contexts is discussed, and although it is important to acknowledge the benefit of standardized screening test sets, issues relating to the relevance of test sets to clinical activities remain. The degree of correlation between performance based on real-life clinical audit and performances at screen read test sets must be better understood and specific causal agents for any lack of correlation identified.

  18. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    Science.gov (United States)

    Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J

    2011-01-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  19. Effect of Kiken-Yochi training (KYT) induction on patient safety at the department of radiological technology

    International Nuclear Information System (INIS)

    Yasuda, Mitsuyoshi; Uchiyama, Yushi; Sakiyama, Koshi; Shibata, Masako; Sasaki, Haruaki; Kato, Kyoichi; Nakazawa, Yasuo; Sanbe, Takeyuki; Yoshikawa, Kohki

    2013-01-01

    In this report, we evaluated whether radiological technologists' (RTs') awareness of patient safety would improve and what kind of effects would be seen at the department of radiological technology by introducing KYT [K: kiken (hazard), Y: yochi (prediction), T: (training)]. KYT was carried out by ten RTs based on a KYT sheet for the department of radiological technology. To evaluate the effects of KYT, we asked nine questions each to ten participants before and after KYT enforcement with regard to their attitude to patient safety and to operating procedures for working safely. Significant improvements after KYT enforcement were obtained in two items concerning medical safety: It is important for any risk to be considered by more than one person; The interest in preventive measures against medical accident degree conducted now) and one concerning operating procedures (It is necessary to have a nurse assist during testing with the mobile X-ray apparatus) (p<0.05). Performing KYT resulted in improved awareness of the importance of patient safety. KYT also enabled medical staffers to evaluate objectively whether the medical safety measures currently performed would be effective for patients. (author)

  20. Radiological diagnosis of pulmonary hypertension

    International Nuclear Information System (INIS)

    Huebsch, P.; Jenny, C.; Schwaighofer, B.; Seidl, G.; Burghuber, O.C.

    1987-01-01

    In 43 patients with obstructive and restrictive lung disease a catheterisation of the right heart with measurement of pulmonary artery pressure was performed. In a retrospective study several radiological parameters of pulmonary hypertension were evaluated on the chest radiographs of these patients. Considering those parameters on the p.a. and lateral chest radiograph, the diagnosis of pulmonary hypertension in patients with elevated pulmonary artery pressure at rest can be made with great accuracy. When pulmonary artery pressure is elevated only during exercise, the accuracy of radiological diagnosis is much lower. (orig.) [de

  1. Effect of Massed Versus Interleaved Teaching Method on Performance of Students in Radiology.

    Science.gov (United States)

    Rozenshtein, Anna; Pearson, Gregory D N; Yan, Sherry X; Liu, Andrew Z; Toy, Dennis

    2016-08-01

    Radiology instruction is based on the principle that grouped (or massed) repetition of an intellectual activity leads to expertise. The aim of this study was to test the hypothesis that the spaced (or interleaved) method of teaching chest x-ray interpretation is more effective than the massed method. After institutional review board approval was obtained, 40 first- and second-year medical students were randomized into two groups matched by age, gender, and education experience. Both groups saw six examples of 12 common chest radiographic patterns, one grouped, the other scrambled randomly without repeating strings. After a distraction, participants took a multiple-choice test consisting of two cases in each radiographic pattern, one previously shown, one new. Results were analyzed using two-tailed Student's t test of proportion. Comparing interleaved and massed groups, the average overall score was 57% versus 43% (P = .03), the recollection score was 61% versus 47% (P = .03), and the induction score was 53% versus 40% (P = 0.10), respectively. Comparing second- and first-year students, average scores were 67% and 39%, respectively (P method of instruction leads to better results than the massed method across all levels of education. A higher level of medical education improves performance independent of method of instruction. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Methodology of teaching and new challenges in the training of professionals in the area of industrial radiology

    International Nuclear Information System (INIS)

    Lima, C.M. Araujo; Pelegrineli, S.Q.; Lima, A.R.

    2017-01-01

    One of the main causes of radiological accidents is the lack of knowledge in radiological protection of workers. In order to meet the needs of professionals in radiology techniques in training in industrial radiology and radiological protection, the Training Course in Industrial Radiology was created in 2009 by MAXIM, in partnership with the Casa Branca Faculty. The objective is to present the structure and methodology of teaching used in this course to reach the objectives of training professionals with solid knowledge in industrial radiology, as well as to mention the challenges of this training. For the elaboration of the study, a statistical data base and theoretical analysis of the teaching structure of the course was used. Professional training in industrial radiology is subdivided into basic, specific, practical and complementary modules, totaling a workload of 360 hours. It is noted that most of the professionals trained come from the great urban centers of the country, favoring employability in the port terminals and industries that are located in these regions. It is concluded, therefore, that it is necessary and of great importance for the growing industrial market, the formation of new professionals, mainly in cities of the interior

  3. Joining Distributed Complex Objects: Definition and Performance

    NARCIS (Netherlands)

    Teeuw, W.B.; Teeuw, Wouter B.; Blanken, Henk

    1992-01-01

    The performance of a non-standard distributed database system is strongly ifluenced by complex objects. The effective exploitation of parallelism in querying them and a suitable structure to store them are required in order to obtain acceptable response times in these database environments where

  4. Curriculum in radiology for residents: what, why, how, when, and where.

    Science.gov (United States)

    Collins, J

    2000-02-01

    Developing a curriculum in chest radiology should follow the same general principles that are used when developing a curriculum in any subspecialty area of radiology. A curriculum is more than a "list of topics" with which a resident should be familiar after 4 years of training. It includes objectives and goals, content, faculty, methods, and evaluation. Numerous resources are available for those who are charged with developing a curriculum in chest radiology. In addition to faculty members in the department, whose input during development can ensure successful implementation of the curriculum, organizations (i.e., ACR, APDR, STR) already have begun to develop "model" curricula. Attending the annual meeting of the Association of American Medical Colleges is a way to meet and hear from professionals who develop and oversee curriculum development at their medical schools, and another important resource available at some medical schools is the Office of Medical Education. The faculty within such offices are uniquely qualified to assist with curriculum and faculty development, especially for those areas in which radiology faculty traditionally are less experienced, such as development of valid and reliable assessment forms and construction of behaviorally based objectives.

  5. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong

    2017-01-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  6. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)

    2017-10-15

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  7. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins

    International Nuclear Information System (INIS)

    Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.

    2012-01-01

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  8. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    Science.gov (United States)

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  9. Tool for objective quantification of pulmonary sequelae in monitoring of patients with tuberculosis

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Alvarez, Matheus; Pina, Diana R. de; Bacchim Neto, Fernando A.; Pereira, Paulo C.M.; Ribeiro, Sergio M.; Miranda, Jose Ricardo de A.

    2014-01-01

    Tuberculosis (TB), caused by Mycobacterium tuberculosis, is an ancient infectious disease that remains a global health problem. Chest radiography is the method commonly employed in assessing the evolution of TB. However, lung damage quantification methods are usually performed on a computerized tomography (CT). This objective quantification is important in the radiological monitoring of the patient by assessing the progression and treatment of TB. However, precise quantification is not feasible by the number of CT examinations necessary due to the high dose subjected to the patient and high cost to the institution. The purpose of this work is to develop a tool to quantify pulmonary sequelae caused by TB through chest X-rays. Aiming the proposed objective, a computational algorithm was developed, creating a three-dimensional representation of the lungs, with regions of dilated sequelae inside. It also made the quantification of pulmonary sequelae of these patients through CT scans performed in upcoming dates, minimizing the differences in disease progression. The measurements from the two methods were compared with results suggest that the effectiveness and applicability of the developed tool, allowing lower doses radiological monitoring of the patient during treatment

  10. Radiological Situation at the Bomb Test Sites

    International Nuclear Information System (INIS)

    Valkovic, V.

    1998-01-01

    An overview of radiological situation at the selected bomb test sites is presented. The report is based on the reports and measurements performed by IAEA while the author was a head of its Physics-Chemistry-Instrumentation Laboratory. Radiological conditions at Bikini Atoll (USA testing ground), Mururoa and Fangataufa Atolls (French testing ground) and Semipalatinsk (SSSR testing ground) have been discussed in some details. (author)

  11. Radiological study of bronchial mucoid impaction

    International Nuclear Information System (INIS)

    Yu Xiaoyi; Yan Hongzhen; Wang Tongde; Gan Chunlan; Liu Wei; Wang Linhui

    1999-01-01

    Objective: To evaluate the radiological findings of bronchial mucoid impaction in 28 patients in order to improve diagnostic efficacy. Methods: Standard posteroanterior high voltage radiographs were performed in all 28 cases. Among them CT scans were taken in 14 cases, while 3 patients underwent HRCT examination at the same time. Twenty-two patients had a history of expectoration of mucous plugs; in one case with pulmonary atelectasis, a mucous plug was picked out through bronchoscopy. The other 5 cases experienced a lung operation, and a tumor and bronchial mucoid impaction were discovered. Results: Radiographs showed most mucoid impaction as thick, branching structures resembling branches of tree; others were in the shapes of spherical, small clubs, and cuttle fish. In one patient, pulmonary atelectasis was the only radiographic finding. Similarly on CT, most bronchial mucoid impaction were likened to tree branches; the rest presented as small clubs and bunches of grape. A prominent feature of bronchial mucoid impaction, either on plain radiograph or on CT, was that its axis pointed to the hilum, completely consistent with the branching and distribution of the bronchi, and accompanied by bronchiectasis. Conclusions: It is an optimal approach to exploit plain radiograph combined with CT to find out bronchial mucoid impaction. An awareness of its clinical and radiological features may improve better understanding and recognition of the disease

  12. Application of historical Y-12 default radiological activity values to legacy waste

    International Nuclear Information System (INIS)

    Coleman, G.

    2009-01-01

    In June of 2003, Bechtel Jacobs Company LLC tasked Pacific Western Technologies (PWT) to perform a comprehensive audit of the Facility Acceptance Testing/ Container Analysis Tool (FAT-CAT), which is currently administered, by Bechtel Jacobs Company LLC... During this audit, a finding was issued on the subject of assigning historic Y-12 default radiological activity values to radiological containers, having no radiological data. Analysis of default radiological values versus known real radiological values showed the default values to be conservative as a place-holder for containers with no known radiological values. (authors)

  13. Informatics in radiology: automated Web-based graphical dashboard for radiology operational business intelligence.

    Science.gov (United States)

    Nagy, Paul G; Warnock, Max J; Daly, Mark; Toland, Christopher; Meenan, Christopher D; Mezrich, Reuben S

    2009-11-01

    Radiology departments today are faced with many challenges to improve operational efficiency, performance, and quality. Many organizations rely on antiquated, paper-based methods to review their historical performance and understand their operations. With increased workloads, geographically dispersed image acquisition and reading sites, and rapidly changing technologies, this approach is increasingly untenable. A Web-based dashboard was constructed to automate the extraction, processing, and display of indicators and thereby provide useful and current data for twice-monthly departmental operational meetings. The feasibility of extracting specific metrics from clinical information systems was evaluated as part of a longer-term effort to build a radiology business intelligence architecture. Operational data were extracted from clinical information systems and stored in a centralized data warehouse. Higher-level analytics were performed on the centralized data, a process that generated indicators in a dynamic Web-based graphical environment that proved valuable in discussion and root cause analysis. Results aggregated over a 24-month period since implementation suggest that this operational business intelligence reporting system has provided significant data for driving more effective management decisions to improve productivity, performance, and quality of service in the department.

  14. Questionnaire surveys of dentists on radiology.

    Science.gov (United States)

    Shelley, A M; Brunton, P; Horner, K

    2012-05-01

    Survey by questionnaire is a widely used research method in dental radiology. A major concern in reviews of questionnaires is non-response. The objectives of this study were to review questionnaire studies in dental radiology with regard to potential survey errors and to develop recommendations to assist future researchers. A literature search with the software search package PubMed was used to obtain internet-based access to Medline through the website www.ncbi.nlm.nih.gov/pubmed. A search of the English language peer-reviewed literature was conducted of all published studies, with no restriction on date. The search strategy found articles with dates from 1983 to 2010. The medical subject heading terms used were "questionnaire", "dental radiology" and "dental radiography". The reference sections of articles retrieved by this method were hand-searched in order to identify further relevant papers. Reviews, commentaries and relevant studies from the wider literature were also included. 53 questionnaire studies were identified in the dental literature that concerned dental radiography and included a report of response rate. These were all published between 1983 and 2010. In total, 87 articles are referred to in this review, including the 53 dental radiology studies. Other cited articles include reviews, commentaries and examples of studies outside dental radiology where they are germane to the arguments presented. Non-response is only one of four broad areas of error to which questionnaire surveys are subject. This review considers coverage, sampling and measurement, as well as non-response. Recommendations are made to assist future research that uses questionnaire surveys.

  15. Decreased attention to object size information in scale errors performers

    NARCIS (Netherlands)

    Grzyb, B.J.; Cangelosi, A.; Cattani, A.; Floccia, C.

    2017-01-01

    Young children sometimes make serious attempts to perform impossible actions on miniature objects as if they were full-size objects. The existing explanations of these curious action errors assume (but never explicitly tested) children’s decreased attention to object size information. This study

  16. Radiological impacts from nuclear facilities on non-human species

    International Nuclear Information System (INIS)

    1997-07-01

    This monograph is the Proceedings of a Symposium on Radiological Impacts from Nuclear Facilities on Non-Human Species, held in Ottawa, Canada, December 1 and 2, 1996. The Symposium was held in response to the assessment of radiological impacts from nuclear facilities on non-human biota by Environment Canada and the move by Atomic Energy Control Board to include the radiological impacts in its regulatory regime. The two major goals of the Symposium were to critically evaluate the ecological risk assessment as applied to radionuclides and contribute to the wide consultation sought by the Atomic Energy Control Board on their new environmental initiatives. The series of papers presented at the Symposium discuss issues relevant to the two major objectives of the Symposium

  17. Quantum non-objectivity from performativity of quantum phenomena

    International Nuclear Information System (INIS)

    Khrennikov, Andrei; Schumann, Andrew

    2014-01-01

    We analyze the logical foundations of quantum mechanics (QM) by stressing non-objectivity of quantum observables, which is a consequence of the absence of logical atoms in QM. We argue that the matter of quantum non-objectivity is that, on the one hand, the formalism of QM constructed as a mathematical theory is self-consistent, but, on the other hand, quantum phenomena as results of experimenters’ performances are not self-consistent. This self-inconsistency is an effect of the language of QM differing greatly from the language of human performances. The former is the language of a mathematical theory that uses some Aristotelian and Russellian assumptions (e.g., the assumption that there are logical atoms). The latter language consists of performative propositions that are self-inconsistent only from the viewpoint of conventional mathematical theory, but they satisfy another logic that is non-Aristotelian. Hence, the representation of quantum reality in linguistic terms may be different: the difference between a mathematical theory and a logic of performative propositions. To solve quantum self-inconsistency, we apply the formalism of non-classical self-referent logics. (paper)

  18. Quality measures and pediatric radiology: suggestions for the transition to value-based payment

    Energy Technology Data Exchange (ETDEWEB)

    Heller, Richard E. [Radiology Partners, El Segundo, CA (United States); Coley, Brian D. [University of Cincinnati, Department of Radiology and Medical Imaging, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Simoneaux, Stephen F. [Emory University School of Medicine, Department of Radiology, Children' s Healthcare of Atlanta, Atlanta, GA (United States); Podberesky, Daniel J. [Nemours Children' s Hospital, Department of Radiology, Nemours Children' s Health System, Orlando, FL (United States); Hernanz-Schulman, Marta [Vanderbilt University School of Medicine, Department of Radiology, Monroe Carell Jr. Children' s Hospital at Vanderbilt, Nashville, TN (United States); Robertson, Richard L. [Harvard Medical School, Department of Radiology, Boston Children' s Hospital, Boston, MA (United States); Donnelly, Lane F. [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States)

    2017-06-15

    Recent political and economic factors have contributed to a meaningful change in the way that quality in health care, and by extension value, are viewed. While quality is often evaluated on the basis of subjective criteria, pay-for-performance programs that link reimbursement to various measures of quality require use of objective and quantifiable measures. This evolution to value-based payment was accelerated by the 2015 passage of the Medicare Access and CHIP (Children's Health Insurance Program) Reauthorization Act (MACRA). While many of the drivers of these changes are rooted in federal policy and programs such as Medicare and aimed at adult patients, the practice of pediatrics and pediatric radiology will be increasingly impacted. This article addresses issues related to the use of quantitative measures to evaluate the quality of services provided by the pediatric radiology department or sub-specialty section, particularly as seen from the viewpoint of a payer that may be considering ways to link payment to performance. The paper concludes by suggesting a metric categorization strategy to frame future work on the subject. (orig.)

  19. Quality measures and pediatric radiology: suggestions for the transition to value-based payment

    International Nuclear Information System (INIS)

    Heller, Richard E.; Coley, Brian D.; Simoneaux, Stephen F.; Podberesky, Daniel J.; Hernanz-Schulman, Marta; Robertson, Richard L.; Donnelly, Lane F.

    2017-01-01

    Recent political and economic factors have contributed to a meaningful change in the way that quality in health care, and by extension value, are viewed. While quality is often evaluated on the basis of subjective criteria, pay-for-performance programs that link reimbursement to various measures of quality require use of objective and quantifiable measures. This evolution to value-based payment was accelerated by the 2015 passage of the Medicare Access and CHIP (Children's Health Insurance Program) Reauthorization Act (MACRA). While many of the drivers of these changes are rooted in federal policy and programs such as Medicare and aimed at adult patients, the practice of pediatrics and pediatric radiology will be increasingly impacted. This article addresses issues related to the use of quantitative measures to evaluate the quality of services provided by the pediatric radiology department or sub-specialty section, particularly as seen from the viewpoint of a payer that may be considering ways to link payment to performance. The paper concludes by suggesting a metric categorization strategy to frame future work on the subject. (orig.)

  20. Diagnosis of radiological security of installations; Diagnostico de la seguridad radiologica de instalaciones

    Energy Technology Data Exchange (ETDEWEB)

    Herrera V, L [Laboratorio de Vigilancia Radiologica Ambiental, Gerencia de Seguridad del ININ (Mexico)

    1991-07-01

    The objective of this work is to discuss the diagnosis of the radiological safety of nuclear or radioactive facilities. It was concluded that the one diagnoses like discipline of the radiological safety is susceptible of being represented, taught and programmable in computer and useful systems as preventive tool and of inspection.

  1. Performance evaluation software moving object detection and tracking in videos

    CERN Document Server

    Karasulu, Bahadir

    2013-01-01

    Performance Evaluation Software: Moving Object Detection and Tracking in Videos introduces a software approach for the real-time evaluation and performance comparison of the methods specializing in moving object detection and/or tracking (D&T) in video processing. Digital video content analysis is an important item for multimedia content-based indexing (MCBI), content-based video retrieval (CBVR) and visual surveillance systems. There are some frequently-used generic algorithms for video object D&T in the literature, such as Background Subtraction (BS), Continuously Adaptive Mean-shift (CMS),

  2. Study of photoconductor-based radiological image sensors

    International Nuclear Information System (INIS)

    Beaumont, Francois

    1989-01-01

    Because of the evolution of medical imaging techniques to digital Systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitizable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i.e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radiographed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo-carrier trapping at dielectric-photoconductor structure interface. The reading System needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging System. The originality of thermo-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen System consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr

  3. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    LENUS (Irish Health Repository)

    Marshall, Nina L

    2011-09-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  4. General Employee Radiological Training and Radiological Worker Training: Program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE General Employee Radiological Training (GERT) and Radiological Worker I and II (RW I and II) Training programs. It includes material development requirements, standards and policies, and program administration. This manual applies to General Employee Radiological Training and Radiological Worker Training at all DOE contractor sites. The training materials of both GERT and RW I and II training reflect the requirements identified in the DOE Radiological Control Manual and DOE Order 5480.11. The training programs represent the minimum requirement for the standardized core materials. Each contractor shall implement the program in its entirety and may augment the standardized core materials to increase the general employee and radiological worker level of competency

  5. The Oxford unicompartmental knee arthroplasty: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, K. [Department of Orthopaedic Radiology, University Hospital of Wales, Cardiff (United Kingdom)], E-mail: kausik.mukherjee@cardiffandvale.wales.nhs.uk; Pandit, H. [North Hampshire Hospital, Basingstoke (United Kingdom); Nuffield Department of Orthopaedic Surgery, University of Oxford, Headington (United Kingdom); Dodd, C.A.F.; Ostlere, S. [Nuffield Orthopaedic Centre, Headington (United Kingdom); Murray, D.W. [Nuffield Department of Orthopaedic Surgery, University of Oxford, Headington (United Kingdom)

    2008-10-15

    Unicompartmental knee arthroplasty (UKA) is increasingly being performed in both specialist centres as well as district hospitals. The radiologists should be aware of the required preoperative imaging, the normal appearance, and complications of this procedure. Unfortunately, very little is available in the radiology literature. This review aims to provide a radiological perspective to an already widely used procedure.

  6. Clinical, radiological and sonographic correlation in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Giuseppetti, G.M.; Giovannoni, A.; Baldelli, S.; Bordoni, E.

    1986-01-01

    The results of US study on parathyroid glands, performed in 75 hemodialysed patients are reported. The correlation between morphological feature of the glands, biochemical and radiological pattern of secondary hyperparathyroidism is stressed. The results show a significant link between gland volume and hematic level of PTH: less interesting appears the correlation with radiological pattern of uremic osteodystrophy

  7. Guidelines for selection of radiological protective head covering

    International Nuclear Information System (INIS)

    Galloway, G.R. Jr.

    1995-08-01

    The hood is recognized throughout the nuclear industry as the standard radiological protective head covering for use in radioactively contaminated work environments. As of June 15, 1995, hoods were required for all activities performed in contaminated areas at the Y-12 Plant. The use of hoods had historically been limited to those radiological activities with a high potential for personnel contamination. Due to the large size of many posted contaminated areas at the Y-12 Plant, and compounding safety factors, requirements for the use of hoods are being reevaluated. The purpose of the evaluation is to develop technically sound guidelines for the selection of hoods when prescribing radiological protective head covering. This report presents the guidelines for selection of radiological protective hoods

  8. A Comprehensive Analysis of Authorship in Radiology Journals.

    Science.gov (United States)

    Dang, Wilfred; McInnes, Matthew D F; Kielar, Ania Z; Hong, Jiho

    2015-01-01

    The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946-2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors' full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. 216,271 articles from 1946-2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, Pjournals, country of origin, language of publication and article type. Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines.

  9. The social and cultural construction of radiological risk: a case study

    International Nuclear Information System (INIS)

    Van Nuffelen, D.

    1996-01-01

    Man, society or culture, considered as objects, cannot be measured in the same way as one would measure gravity or a hyperbola. In these conditions, how can one isolate the socio-anthropological aspects from the overall perception of radiological risks, thus the nuclear question? This paper deals with an empirical study derived from some fundamental research conducted in order to explain how different social actors conceive the nuclear question by means of different social construction of reality. It fits into the sociological scheme of knowledge posing a set of methodological and theoretical questions that have as the object the study of the social determinants of knowledge related to the nuclear question. The present survey, carried out in Belgian agricultural workers, makes clear how such determinants interact to form one social construction of the radiological risk. It allows us to presume that the perception of the radiological risks cannot be reduced to some laypeople's measurable psychic (mis)perceptions. (author)

  10. Pediatric interventional radiology: vascular interventions

    International Nuclear Information System (INIS)

    Kandasamy, Devasenathipathy; Gamanagatti, Shivanand; Gupta, Arun Kumar

    2016-01-01

    Pediatric interventional radiology (PIR) comprises a range of minimally invasive diagnostic and therapeutic procedures that are performed using image guidance. PIR has emerged as an essential adjunct to various surgical and medical conditions. Over the years, technology has undergone dramatic and continuous evolution, making this speciality grow. In this review, the authors will discuss various vascular interventional procedures undertaken in pediatric patients. It is challenging for the interventional radiologist to accomplish a successful interventional procedure. There are many vascular interventional radiology procedures which are being performed and have changed the way the diseases are managed. Some of the procedures are life saving and have become the treatment of choice in those patients. The future is indeed bright for the practice and practitioners of pediatric vascular and non-vascular interventions. As more and more of the procedures that are currently being performed in adults get gradually adapted for use in the pediatric population, it may be possible to perform safe and successful interventions in many of the pediatric vascular lesions that are otherwise being referred for surgery. (author)

  11. TH-E-201-03: A Radiology Resident’s Perspectives of Physics Teaching

    Energy Technology Data Exchange (ETDEWEB)

    Key, A. [University of Kentucky (United States)

    2016-06-15

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.

  12. TH-E-201-03: A Radiology Resident’s Perspectives of Physics Teaching

    International Nuclear Information System (INIS)

    Key, A.

    2016-01-01

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant

  13. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  14. High Performance Object-Oriented Scientific Programming in Fortran 90

    Science.gov (United States)

    Norton, Charles D.; Decyk, Viktor K.; Szymanski, Boleslaw K.

    1997-01-01

    We illustrate how Fortran 90 supports object-oriented concepts by example of plasma particle computations on the IBM SP. Our experience shows that Fortran 90 and object-oriented methodology give high performance while providing a bridge from Fortran 77 legacy codes to modern programming principles. All of our object-oriented Fortran 90 codes execute more quickly thatn the equeivalent C++ versions, yet the abstraction modelling capabilities used for scentific programming are comparably powereful.

  15. Panoramic radiology. Seminars on maxillofacial imaging and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Farman, Allan G. (ed.) [Louisville Univ., KY (United States). Dept. of Surgical and Hospital Dentistry

    2007-07-01

    Complete up-to-date collection of information on panoramic radiography usage. Up-to-date terminology validated by representatives of individual special disciplines within dentistry. Each chapter with educational objectives and review questions. Panoramic radiology systems are currently being used in more practices than at other any time in the past. The practitioner now has decisions to make regarding detector technology selection for image acquisition and must remain informed about appropriate usage. This book is applicable to all panoramic dental images and equipment. It approaches panoramic radiology usage in the context of general and specialty applications. (orig.)

  16. ALARA tools and performance indicators at Cernavoda NPP

    International Nuclear Information System (INIS)

    Chitu, C.; Popescu, V.; Simionov, V.

    2009-01-01

    Work efficiency is an area of high concern to nuclear power plant operators. Job planning has to be done so that there will be enough time for ALARA actions to be implemented. The control of the activities involving radiological risk is part of ALARA Process. An effective control supposes the implementation of a process to systematically identify the activities performed in radiological areas. Plant Performance Indicators related to ionizing radiation exposure have been established to improve station safe performance. They are assessed and reported periodically to reflect the safe operation objectives. If target values are exceeded 'abnormal condition reports' are generated. Corrective and preventive actions aim at work planning, technical aspects, and human performance. All the staff is informed about these events and corrective actions described through the training program are implemented. (authors)

  17. Establishing a health outcomes and economics center in radiology: strategies and resources required

    International Nuclear Information System (INIS)

    Medina, Santiago L.; Altman, Nolan R.

    2002-01-01

    To describe the resources and strategies required to establish a health outcomes and economics center in radiology.Methods. Human and nonhuman resources required to perform sound outcomes and economics studies in radiology are reviewed.Results. Human resources needed include skilled medical and nonmedical staff. Nonhuman resources required are: (1) communication and information network; (2) education tools and training programs; (3) budgetary strategies; and (4) sources of income. Effective utilization of these resources allows the performance of robust operational and clinical research projects in decision analysis, cost-effectiveness, diagnostic performance (sensitivity, specificity, and ROC curves), and clinical analytical and experimental studies.Conclusion. As new radiologic technology and techniques are introduced in medicine, society is increasingly demanding sound clinical studies that will determine the impact of radiologic studies on patient outcome. Health-care funding is scarce, and therefore third-party payers and hospitals are demanding more efficiency and productivity from radiologic service providers. To meet these challenges, radiology departments could establish health outcomes and economics centers to study the clinical effectiveness of imaging and its impact on patient outcome. (orig.)

  18. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology

    International Nuclear Information System (INIS)

    Mori, Hiroshige

    2015-01-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses’ annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units’ pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses. (practical matter)

  19. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    Science.gov (United States)

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  20. Adult Learning Principles for Effective Teaching in Radiology ...

    African Journals Online (AJOL)

    BACKGROUND: Adult learning processes of acquisition of new knowledge, behaviours, skills, values or preferences generally occur as part of personal professional development. There is need for radiology residency trainers to understand the basic adult learning principles for effective teaching processes. OBJECTIVE: To ...

  1. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A.; Oudkerk, Matthijs; Van Ooijen, Peter M. A.

    Objectives: To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical

  2. Effective dose delivered by conventional radiology to Aosta Valley population between 2002 and 2009

    Science.gov (United States)

    Zenone, F; Aimonetto, S; Catuzzo, P; Peruzzo Cornetto, A; Marchisio, P; Natrella, M; Rosanò, A M; Meloni, T; Pasquino, M; Tofani, S

    2012-01-01

    Objective Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009. Method Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose. Results The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose. Conclusion The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009. PMID:21937611

  3. Quality initiatives: lean approach to improving performance and efficiency in a radiology department.

    Science.gov (United States)

    Kruskal, Jonathan B; Reedy, Allen; Pascal, Laurie; Rosen, Max P; Boiselle, Phillip M

    2012-01-01

    Many hospital radiology departments are adopting "lean" methods developed in automobile manufacturing to improve operational efficiency, eliminate waste, and optimize the value of their services. The lean approach, which emphasizes process analysis, has particular relevance to radiology departments, which depend on a smooth flow of patients and uninterrupted equipment function for efficient operation. However, the application of lean methods to isolated problems is not likely to improve overall efficiency or to produce a sustained improvement. Instead, the authors recommend a gradual but continuous and comprehensive "lean transformation" of work philosophy and workplace culture. Fundamental principles that must consistently be put into action to achieve such a transformation include equal involvement of and equal respect for all staff members, elimination of waste, standardization of work processes, improvement of flow in all processes, use of visual cues to communicate and inform, and use of specific tools to perform targeted data collection and analysis and to implement and guide change. Many categories of lean tools are available to facilitate these tasks: value stream mapping for visualizing the current state of a process and identifying activities that add no value; root cause analysis for determining the fundamental cause of a problem; team charters for planning, guiding, and communicating about change in a specific process; management dashboards for monitoring real-time developments; and a balanced scorecard for strategic oversight and planning in the areas of finance, customer service, internal operations, and staff development. © RSNA, 2012.

  4. Pneumonia caused by Pittsburgh pneumonia agent: radiologic manifestations

    International Nuclear Information System (INIS)

    Muder, R.R.; Reddy, S.C.; Yu, V.L.; Kroboth, F.J.

    1984-01-01

    Using an objective scoring system, chest radiographs were reviewed in 23 cases of pneumonia due to the Pittsburgh pneumonia agent (PPA, Tatlockia micdadei, Legionella micdadei), including six cases of pneumonia with simultaneous isolation of PPA and L pneumophila (Legionnaires' disease). Infiltrates were typically segmental to lobar; nodular infiltrates were noted in three cases. Spread to additional lobes after presentation occurred in four of 17 PPA infections. Pneumonia caused by both PPA and L pneumophila was unusually severe, with involvement of all lobes occurring in four of six cases, compared with one of 17 cases of PPA infection (p>0.02). Radiographic severity did not correlate with underlying disease, immune status, or outcome. The majority of patients receiving erythromycin demonstrated objective radiologic improvement. In a patients, population that included nonimmunosuppressed patient, nodule formation and rapid radiologic progression were not found to be characteristic of PPA pneumonia

  5. Digital image information systems in radiology

    International Nuclear Information System (INIS)

    Greinacher, C.F.C.; Luetke, B.; Seufert, G.

    1987-01-01

    About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de

  6. An Internet-Based Radiology Course in Medical School: Comparison of Academic Performance of Students on Campus Versus Those With Absenteeism Due to Residency Interviews.

    Science.gov (United States)

    Alexander, Andrew George; Deas, Deborah; Lyons, Paul Eric

    2018-05-18

    objectives to be successfully met without adversely affecting the outcomes on a nationally normed examination in radiology. A curriculum that includes online content and live Web-based teleconference access to faculty can accomplish both imperatives. ©Andrew George Alexander, Deborah Deas, Paul Eric Lyons. Originally published in JMIR Medical Education (http://mededu.jmir.org), 18.05.2018.

  7. Radiologic protection in dental radiology

    International Nuclear Information System (INIS)

    Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.

    2000-01-01

    With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)

  8. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  9. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  10. Patient dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Rweyemamu, M.

    2013-04-01

    The objective of this project was to review patient dosimetry aiming at reducing the patient dose during diagnostic procedures while maintaining the best image quality in order to protect patients from ionizing radiation. CT examination was selected in this study to represent imaging protocols with high patient doses used in diagnostic radiology. Dosimetric parameters in CT which are CTDI, CTDIW, DLP, MSAD, organ dose and effective dose were discussed. Parameters such as tube current, tube voltage, filtration, scan volume and slice thickness were found to affect patient dose, therefore proper management of these factors was recommended. For optimization of protection of the patient, application of the “as low as reasonably achievable” (ALARA) principle was recommended as an important key for avoiding overexposure and minimizing patient doses. Also it was recommended that CT examinations should be performed if and only if is the only suitable option when weighed against other options which do not involve ionizing radiation exposure. (author)

  11. eLearning-radiology.com. Sustainability for quality assurance; eLearning-radiology.com. Nachhaltigkeit im Sinne der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Talanow, R. [Cleveland Clinic, Cleveland, OH (United States). Abt. fuer Nuklearmedizin; Uder, M. [Erlangen-Nuernberg Univ. (Germany). Inst. fuer Diagnostische Radiologie; Grunewald, M. [Erlangen-Nuernberg Univ. (Germany). Nuklearmedizinische Klinik

    2009-04-15

    Purpose: The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Materials and Methods: Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. Results: At the time of assessment, 56.4 % (102/181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. (orig.)

  12. Work procedures and risk factors for high rdiation exposure among radiologic technologists in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Young; Choi, Yeong Chull [Dept. of Preventive Medicine, Keimyung University College of Medicine, Daegu (Korea, Republic of); Lee, Won Jin; Cha, Eun Shil [Dept. of Preventive Medicine, Korea University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.

  13. Work procedures and risk factors for high rdiation exposure among radiologic technologists in South Korea

    International Nuclear Information System (INIS)

    Kim, Jae Young; Choi, Yeong Chull; Lee, Won Jin; Cha, Eun Shil

    2016-01-01

    Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.

  14. The radiological manifestation of hypophosphatasia

    International Nuclear Information System (INIS)

    Chen Haisong; Li Xiaofei; Han Yan; Cao Qingxuan; Xu Wenjian

    2012-01-01

    Objective: To explore the radiological features of hypophosphatasia. Methods: Five cases of hypophosphatasia were definitely diagnosed, which included 3 males and 2 females aged from 5 months to 23 years. The laboratory assays were analyzed, radiological appearances of bone were determined and differential diagnoses were made. Results: The alkaline phosphatase in blood serum of five patients decreased, which were 8, 20, 13, 21, and 18 U/L respectively. Phosphoethanolamine increased in blood serum of the five patients, which were 16.5, 13.5, 21.6, 18.7, and 28.9 μmol/L respectively. Phosphoethanolamine also increased in urine,which were 2350, 9120, 3520, 5280, and 1820 μmol/L respectively. Calcium in blood serum increased, which were 4.2, 5.6, 4.9, 6.1, and 3.5 mmol/L respectively. X-ray images displayed that the density of bone decreased in 5 cases, the metaphyses exhibited widening and cupping in 4 cases, the provisional calcification zone of the metaphysis became thinning or disappearing in 4 cases, long bone bended in 4 cases and pathologically fractured in 1 case. Conclusion: Hypophosphatasia can be indicated by its relatively special radiological appearance, and it can be diagnosed and differentiated from rickets, osteomalacia and osteogenesis imperfect by the laboratory examination combined with its clinical presentation. (authors)

  15. International Society of Radiology and Radiation Protection

    International Nuclear Information System (INIS)

    Standertskjoeld-Nordenstam, C.G.

    2001-01-01

    The purpose of the International Society of Radiology (ISR), as being the global organization of radiologists, is to promote and help co-ordinate the progress of radiology throughout the world. In this capacity and as a co-operating organization of the IAEA, the ISR has a specific responsibility in the global radiological protection of patients. Globally, there are many users of medical radiation, and radiology may be practised in the most awkward circumstances. The individuals performing X ray studies as well as those interpreting them may be well trained, as in industrialized parts of the world, but also less knowledgeable, as in developing areas. The problems of radiological protection, both of patients and of radiation workers, still exist, and radiation equipment is largely diffused throughout the world. That is why a conference like this is today as important as ever. Radiation protection is achieved through education, on the one hand, and legislation, on the other. Legislation and regulation are the instruments of national authorities. The means of the ISR are education and information. Good radiological practice is something that can be taught. The ISR is doing this mainly through the biannual International Congress of Radiology (ICR), now arranged in an area of radiological need; the three previous ICRs were in China, in India and in South America; the next one is going to be in Mexico in 2002. The goal of the ICR is mainly to be an instructive and educational event, especially designed for the needs of its surrounding region. The ISR is aiming at producing educational material. The International Commission on Radiological Education (ICRE), as part of the ISR, is launching the production of a series of educational booklets, which also include radiation protection. The ICRE is actively involved in shaping and organizing the educational and scientific programme of the ICRs

  16. Solutions in radiology services management: a literature review

    Directory of Open Access Journals (Sweden)

    Aline Garcia Pereira

    2015-10-01

    Full Text Available AbstractObjective:The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services.Materials and Methods:Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares.Results:In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others.Conclusion:Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies.

  17. Solutions in radiology services management: a literature review*

    Science.gov (United States)

    Pereira, Aline Garcia; Vergara, Lizandra Garcia Lupi; Merino, Eugenio Andrés Díaz; Wagner, Adriano

    2015-01-01

    Objective The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services. Materials and Methods Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares. Results In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others. Conclusion Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies. PMID:26543281

  18. Quality assurance programme in diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, A.A.

    1996-01-01

    One hundred years after the discovery of X-rays, they continue being nowadays part of physicians' daily activities, and the diagnosis through the use of X-ray equipment is one of the most important fields in clinical medicine, thus becoming the most important cause of human exposure to artificial sources. For this reason, in the last twenty years, most of the developed countries did the utmost to establish programs which could warrant the quality of the radiographic image. Aiming the protection of human being against the harmful effects of ionizing radiations, in December 1980, World Health Organization decided to form a group of professionals highly experienced in medical radiology, and initiate an inspection and quality control program. In September 1988, the Group of Studies of the Program Related to Radiological Protection of the Commission in the European Communities, prepared a working paper in which guidelines were set up regarding quality of images, dosage to patient, and associated radiographic factors, necessary to obtain acceptable radiologic performance. In Brazil, efforts driven in this direction, guided by some equipment testing, starting in 1990, began to be more known. When the Director and the Head of Radiology in the Military Police Hospital of the State of Rio de Janeiro (HPM) reamed about these efforts, they decided to contact the Institute for Radioprotection and Dosimetry (IRD) of Comissao Nacional de Energia Nuclear and submit the problem of low radiologic performance and increasing rates of rejection. Thus, with the coincidence of interests and needs, along with a proposal from the Commission of the European Communities (CEC), IRD decided to offer the author laboratory support to elaborate a Quality Assurance Program (QAP) to be implemented in HPM. (author)

  19. Training program for radiologic technologists for performing chest X-rays at inspiration in uncooperative children

    International Nuclear Information System (INIS)

    Langen, Heinz Jakob; Muras, S.; Kohlhauser-Vollmuth, C.; Stenzel, M.; Beer, M.

    2009-01-01

    A computer program was created to train technologists to perform chest X-rays in crying infants at maximum inspiration. Videos of 4 children were used. Using a computer program, the moment of deepest inspiration was determined in the video in the single frame view. During the normal running video, 14 technologists (3 with significant experience, 3 with little experience and 8 with very little experience in pediatric radiography) simulated a chest radiograph by pushing a button. The computer program stopped the video and the period of time to the optimal moment for a chest x-ray was calculated. Every technologist simulated 10 chest X-rays in each of the 4 video clips. The technologists then trained themselves to perform chest X-rays at optimal inspiration like playing a computer game. After training, the test was repeated. Changes were evaluated by t-test for unpaired samples (level of significance p < 0.05). Although the differences improved in all children, minimal deviation from the optimal moment for taking an X-ray at inspiration occurred in the periodically crying child (0.21 sec before and 0.13 sec after training). In a non-periodically crying infant, the largest differences were shown. The values improved significantly from 0.29 sec to 0.22 sec. The group with substantial experience in pediatric radiology improved significantly from 0.22 sec to 0.15 sec. The group with very little experience in pediatric radiology showed worse results (improvement from 0.29 sec to 0.21 sec). (orig.)

  20. Radiology and fine art.

    Science.gov (United States)

    Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver

    2012-07-01

    The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.

  1. Pediatric interventional radiology clinic - how are we doing?

    International Nuclear Information System (INIS)

    Rubenstein, Jonathan; Zettel, Julie C.; Lee, Eric; Cote, Michelle; Aziza, Albert; Connolly, Bairbre L.

    2016-01-01

    Development of a pediatric interventional radiology clinic is a necessary component of providing a pediatric interventional radiology service. Patient satisfaction is important when providing efficient, high-quality care. To analyze the care provided by a pediatric interventional radiology clinic from the perspective of efficiency and parent satisfaction, so as to identify areas for improvement. The prospective study was both quantitative and qualitative. The quantitative component measured clinic efficiency (waiting times, duration of clinic visit, nurse/physician time allocation and assessments performed; n = 91). The qualitative component assessed parental satisfaction with their experience with the pediatric interventional radiology clinic, using a questionnaire (5-point Likert scale) and optional free text section for feedback (n = 80). Questions explored the family's perception of relevance of information provided, consent process and overall satisfaction with their pediatric interventional radiology clinic experience. Families waited a mean of 11 and 10 min to meet the physician and nurse, respectively. Nurses and physicians spent a mean of 28 and 21 min with the families, respectively. The average duration of the pediatric interventional radiology clinic consultation was 56 min. Of 80 survey participants, 83% were satisfied with their experience and 94% said they believed providing consent before the day of the procedure was helpful. Only 5% of respondents were not satisfied with the time-efficiency of the interventional radiology clinic. Results show the majority of patients/parents are very satisfied with the pediatric interventional radiology clinic visit. The efficiency of the pediatric interventional radiology clinic is satisfactory; however, adherence to stricter scheduling can be improved. (orig.)

  2. A mobile interventional radiology unit: innovation and social responsibility

    Directory of Open Access Journals (Sweden)

    Nestor Hugo Kisilevzky

    2010-03-01

    Full Text Available Objective: To present the preliminary results of a feasibility study performed to determine the value of a mobile interventional radiology unit used to promote a uterine embolization program for low-income patients. Methods: Forty patients with symptomatic fibroids were treated with uterine embolization. Procedures were performed in four public hospitals in the metropolitan area of Sao Paulo. This study was approved by the institutional research ethics committee and all patients signed an informed consent form. A mobile interventional radiology unit, named ANGIOMOVEL, was conceived and implemented utilizing a small truck to transport one mobile C arm, one radiological table, protection aprons and a small trolley containing specific supplies for the procedures. The ANGIOMOVEL team consisted of two interventional radiologists, one nurse, one driver and one assistant. The unit visited one hospital per week during a three-month period. Patient inclusion was contingent upon several factors, such as evaluation by a trained gynecologist, completion of a pelvic MRI, routine serological laboratory tests and completion of a quality of life questionnaire (QOL. Outcomes, MRI and QOL were evaluated. Data obtained after 12 weeks were collected and analyzed. Results: Technical success was achieved in 100% of cases, with a mean procedure time of 43 minutes and a mean fluoroscopic time of 24 minutes. The mean hospital stay was 1.07 day and the mean time for recovery and return to normal activities was 10 days. After 12 weeks, 36 (90% of patients noticed improvement of their symptoms and 4 (10% did not notice any improvement. Thirty-eight patients (95% were satisfied or very satisfied and 39 (97.5% said they would recommend the procedure. Pre- and post-procedure magnetic resonance imaging analysis showed that complete fibroid ischemia was achieved in 92.5% of cases with a mean uterine volume reduction of 38% and a mean fibroid volume reduction of 52%. Health

  3. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  4. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  5. Radiology and the mobile device: Radiology in motion

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2012-01-01

    Full Text Available The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available.

  6. Radiology and the mobile device: Radiology in motion

    International Nuclear Information System (INIS)

    Panughpath, Sridhar G; Kalyanpur, Arjun

    2012-01-01

    The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available

  7. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    International Nuclear Information System (INIS)

    Kim, Seon Chil

    2008-01-01

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  8. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Chil [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of)

    2008-12-15

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  9. A TWO-STAGE MODEL OF RADIOLOGICAL INSPECTION: SPENDING TIME

    International Nuclear Information System (INIS)

    BROWN, W.S.

    2000-01-01

    The paper describes a model that visually portrays radiological survey performance as basic parameters (surveyor efficiency and criteria, duration of pause, and probe speed) are varied; field and laboratory tests provided typical parameter values. The model is used to illustrate how practical constraints on the time allotted to the task can affect radiological inspection performance. Similar analyses are applicable to a variety of other tasks (airport baggage inspection, and certain types of non-destructive testing) with similar characteristics and constraints

  10. Guidelines on radiology standards for primary dental care

    International Nuclear Information System (INIS)

    1994-01-01

    A Joint Working Party (JWP) on patient dose reduction in diagnostic radiology was established between the Royal College of Radiologists (RCR) and the National Radiological Protection Board (NRPB) towards the end of 1988. JWP identified a large potential for patient dose reduction on a national scale, and a report of its findings was published in 1990. This guidance was only generally applicable to dental radiology and in 1992 a further joint venture between RCR and NRPB resulted in the formation of a Working Party (WP) to consider all aspects of dental radiology applicable to primary dental care. Dental radiology is one of the largest single groups of radiographic examination performed, although the effective dose per radiograph is small. This means that individual risks from dental radiology are low, but WP has identified a significant potential for reduction in the collective dose and for improvements in the diagnostic quality of radiographs. The WP recommendations cover all aspects of dental radiology: training and examination regimes for dentists and staff, patient selection and clinical justification for radiography, diagnostic interpretation, equipment and procedural aspects, and finally the question of quality assurance in dental radiology. The economic impact of the many recommendations by WP has been considered in some detail. The benefits and cost of each recommendation either have been assigned a monetary value or have been assessed more qualitatively. The conclusion is that there is a strong economic justification for implementation of the full package of recommendations. (Author)

  11. The European Union radiological data exchange platform (EURDEP). Recent developments

    International Nuclear Information System (INIS)

    De Cort, M.; De Vries, G.

    1998-01-01

    The technical feasibility for exchanging radiological data was decided within the EU. The JRC-Ispra provides the data exchange platform EURDEP (data capture and transmission) and co-ordinate the communication test exercises. In a first phase a common data format, based on the existing national data formats, is established by which radiological data (gamma dose rate and continuous aerosol measurements) will be exchanged. The 'European network' that will provide the information consists of existing automatic monitoring stations on a 100 x 100 km grid. Various contact points have been successively contacted to exchange radiological data with the JRC. Besides an introduction to the background and objectives of EURDEP, also the experience gained so far in using different communication procedures is discussed. (author)

  12. Radiological emergency: road map for radiation accident victim transport

    International Nuclear Information System (INIS)

    Costa, V.S.G.; Alcantara, Y.P.; Lima, C.M.A.; Silva, F. C. A. da

    2017-01-01

    During a radiological or nuclear emergency, a number of necessary actions are taken, both within the radiation protection of individuals and the environment, involving many institutions and highly specialized personnel. Among them it is possible to emphasize the air transportation of radiation accident victims.The procedures and measures for the safe transport of these radiation accident victims are generally the responsibility of the armed forces, specifically the Aeronautics, with the action denominated 'Aeromedical Military Evacuation of Radiation Accident Victims'. The experience with the Radiological Accident of Goiânia demonstrated the importance of adequate preparation and response during a radiological emergency and the need for procedures and measures with regard to the transport of radiation victims are clearly defined and clearly presented for the effectiveness of the actions. This work presents the necessary actions for the transport of radiation accident victim during a radiological emergency, through the road map technique, which has been widely used in scientific technical area to facilitate understanding and show the way to be followed to reach the proposed objectives

  13. Study of graduate curriculum in the radiological science: problems and suggestions

    International Nuclear Information System (INIS)

    Ko, Seong Jin; Kim, Hwa Gon; Kang, Se Sik; Park, Byeong Rae; Kim, Chang Soo

    2006-01-01

    Currently, Educational program of radiological science is developed in enormous growth, our educational environments leading allied health science education program in the number of super high speed medical industry. Radiological science may be the fastest growing technologies in our medical department today. In this way, Medical industry fields converged in the daily quick, the fact that department of radiological science didn't discharged ones duties on current educational environments. The curriculum of radiological technologists that play an important part between skill and occupation's education as major and personality didn't performed one's part most effectively on current medical environments and digital radiological equipment interface. We expect improvement and suggestion to grow natural disposition as studies in the graduate of radiological science. Therefore, in this paper, current curriculum of radiological science are catched hold of trend and problems on digital radiology environments, on fact the present state of problems, for Graduate program of radiological science, graduate courses of MS and ph.D. are suggested a reform measure of major education curriculum introduction

  14. Patients as partners in radiology education: an innovative approach to teaching and assessing patient-centered communication.

    Science.gov (United States)

    Lown, Beth A; Sasson, J Pierre; Hinrichs, Peg

    2008-04-01

    Effective communication is essential for high quality care, yet little is known about radiologists' communication with patients, what constitutes "best communication practices," and how best to teach and evaluate it. We piloted educational strategies and an assessment instrument to teach and evaluate radiologists' communication skills. We focused on communication in the diagnostic mammography suite, where patient-radiologist interactions are often intense and stressful. We adapted existing instruments to create a Radiology Communication Skills Assessment Tool (RCSAT). We piloted an educational program that included patients as teachers and raters of interpersonal and communication skills, and implemented a radiology objective structured clinical examination (OSCE). We measured radiology residents' self-assessed skills, confidence and stress, as well as patient-rated communication skills using the RCSAT. Residents' baseline self-assessed communication skills regarding abnormal mammograms were fair, confidence in their communication was minimal, and they found this communication stressful. Overall baseline communication skills, rated by patient-teachers using the RCSAT, were 3.62 on a 5-point scale (1 = poor to 5 = excellent). Analysis of post-OSCE debriefing comments yielded nine themes regarding effective radiology communication, as well as residents' reflections on the communication challenges they experience. The themes were integrated into subsequent RCSAT revisions. Residents' reflections were used to inform teaching workshops. Educational curricula on communication about difficult information can be implemented in radiology training programs. Radiology residents' performance can be assessed using a communication skills assessment tool during standardized patient-teacher encounters. Further research is necessary in this important domain.

  15. Protection of staff in interventional radiology

    International Nuclear Information System (INIS)

    Melkamu, M. A.

    2013-04-01

    This project focuses on the interventional radiology. The main objective of this project work was to provide a guidance and advice for occupational exposure and hospital management to optimize radiation protection safety and endorse safety culture. It provides practical information on how to minimize occupational exposure in interventional radiology. In the literature review all considerable parameters to reduce dose to the occupationally exposed are well discussed. These parameters include dose limit, risk estimation, use of dosimeter, personal dose record keeping, analysis of surveillance of occupational dose, investigation levels, and proper use of radiation protection tools and finally about scatter radiation dose rate. In addition the project discusses the ways to reduce occupational exposure in interventional radiology. The methods for dose reduction are minimizing fluoroscopic time, minimizing the number of fluoroscopic image, use of patient dose reduction technologies, use of collimation, planning interventional procedures, positioning in low scattered areas, use of protective shielding, use of appropriate fluoroscopic imaging equipment, giving training for the staff, wearing the dosimeters and know their own dose regularly, and management commitment to quality assurance and quality control system and optimization of radiation protection of safety. (author)

  16. Portrayal of radiology in a major medical television series: How does it influence the perception of radiology among patients and radiology professionals?

    International Nuclear Information System (INIS)

    Heye, T.; Merkle, E.M.; Boll, D.T.; Leyendecker, J.R.; Gupta, R.T.

    2016-01-01

    To assess how the portrayal of Radiology on medical TV shows is perceived by patients and radiology professionals. In this IRB-approved study with patient consent waived, surveys were conducted among adult patients scheduled for radiological examinations and radiology professionals. The questionnaire investigated medical TV watching habits including interest in medical TV shows, appearance of radiological examination/staff, radiology's role in diagnosis-making, and rating of the shows' accuracy in portraying radiology relative to reality. One hundred and twenty-six patients and 240 professionals (133 technologists, 107 radiologists) participated. 63.5 % patients and 63.2 % technologists rated interest in medical TV shows ≥5 (scale 1-10) versus 38.3 % of radiologists. All groups noted regular (every 2nd/3rd show) to >1/show appearance of radiological examinations in 58.5-88.2 % compared to 21.0-46.2 % for radiological staff appearance. Radiology played a role in diagnosis-making regularly to >1/show in 45.3-52.6 %. There is a positive correlation for interest in medical TV and the perception that radiology is accurately portrayed for patients (r = 0.49; P = 0.001) and technologists (r = 0.38; P = 0.001) but not for radiologists (r = 0.01). The majority of patients perceive the portrayed content as accurate. Radiologists should be aware of this cultivation effect to understand their patients' behaviour which may create false expectations towards radiological examinations and potential safety hazards. (orig.)

  17. Fixatives Used for Decommissioning and Maintenance of Radiological Facilities – 17537

    Energy Technology Data Exchange (ETDEWEB)

    Demmer, Rick; Fox, Don; Reese, Stephen; Banford, Anthony; Dodds, Jonathan

    2017-01-01

    The Idaho National Laboratory (INL) and the United Kingdom (UK) National Nuclear Laboratory (NNL) have been collaborating for several years on materials and methods for the fogged/misted introduction of fixatives into radiologically contaminated facilities. The objective of the project is to deliver a process for reducing airborne radiological and/or mercury contamination and affixing loose contamination in place, thereby reducing contamination risk to employees and decreasing D&D cost and schedule. The developed process provides a reliable, unmanned method of introducing a coating that captures and fixes contamination in place within facilities. The INL coating, termed FX2, has undergone extensive non-radiological testing, including determination that it is non-flammable, affixes contamination and flows well through unusual geometries (testing at Florida International University). A series of non-active fogging trials for activity knock/tie-down application have been completed at NNL Workington on behalf of Idaho National Laboratory (INL). These trials performed by the NNL employed commercially available agricultural fogging equipment and the INL’s knock/tie-down latex formulation (FX-2). This testing successfully demonstrated the ability of the fogging devices to successfully spray the FX-2 formulation within various scenarios, and prepared the project for a radioactive trial. The INL has also developed a mercury vapor reducing form of the coating termed FX-Hg, which has shown great promise in laboratory studies.

  18. Hip osteoarthritis in Douala General Hospital: Clinical, radiological ...

    African Journals Online (AJOL)

    Objectives: To describe the epidemiological, clinical and radiological profile of hip OA, and also treatment options offered to patients presenting with this condition at the Douala General Hospital, Cameroon. Methods: After prior ethical clearance, a hospital-based cross sectional descriptive study was carried out, including ...

  19. Osteosarcoma of limb bones: a clinical, radiological and ...

    African Journals Online (AJOL)

    Objectives: To measure the strength of agreement in clinical, radiological and histopathological diagnosis of osteosarcoma in a 5 year study period. Setting: Addis Ababa University, Black-Lion ('Tikur Anbessa') Hospital-BLH, is the country's highest tertiary level referral and teaching hospital. The departments involved in this ...

  20. TH-E-201-02: Hands-On Physics Teaching of Residents in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J. [University of Kentucky (United States)

    2016-06-15

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant.

  1. TH-E-201-02: Hands-On Physics Teaching of Residents in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Zhang, J.

    2016-01-01

    The ABR Core Examination stresses integrating physics into real-world clinical practice and, accordingly, has shifted its focus from passive recall of facts to active application of physics principles. Physics education of radiology residents poses a challenge. The traditional method of didactic lectures alone is insufficient, yet it is difficult to incorporate physics teaching consistently into clinical rotations due to time constraints. Faced with this challenge, diagnostic medical physicists who teach radiology residents, have been thinking about how to adapt their teaching to the new paradigm, what to teach and meet expectation of the radiology resident and the radiology residency program. The proposed lecture attempts to discuss above questions. Newly developed diagnostic radiology residents physics curriculum by the AAPM Imaging Physics Curricula Subcommittee will be reviewed. Initial experience on hands-on physics teaching will be discussed. Radiology resident who will have taken the BAR Core Examination will share the expectation of physics teaching from a resident perspective. The lecture will help develop robust educational approaches to prepare radiology residents for safer and more effective lifelong practice. Learning Objectives: Learn updated physics requirements for radiology residents Pursue effective approaches to teach physics to radiology residents Learn expectation of physics teaching from resident perspective J. Zhang, This topic is partially supported by RSNA Education Scholar Grant

  2. Radiologic protection in intensive therapy units

    International Nuclear Information System (INIS)

    Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S.; Derech, Rodrigo D.A.

    2013-01-01

    The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)

  3. Fetal dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Faulkner, K.

    2002-01-01

    Diagnostic radiology examinations are frequently performed in all countries because of the benefit that the patient derives from the resultant diagnosis. Given that so many examinations are performed it is inevitable that there will be occasions when the planned exposure of a woman who is known to be pregnant is contemplated. In these circumstances, there must be rigorous justification of the examination and the procedure itself must be optimised as well. Radiation risks from fetal irradiation are well established. These risks fall into three categories: 1) a cancer induction risk (mainly leukaemia); 2) hereditary effects (as the fetus is a potential parent); 3) a risk of serious mental retardation (if the fetus is exposed in the critical 8-15 weeks period when the forebrain is being developed). Risk factors for these effects have been reviewed by the International Commission on Radiological Protection. Special rules apply to the radiology of women who are or who may be pregnant. These rules have been developed to avoid he unintended irradiation of the fetus. These rules have been variously referred to as the 10-day rule and the 28-day rules, in which radiology of potentially pregnant women is restricted to the first 10 or 28 days following menstruation. It is apparent that the advice provided by national bodies varies, as different rules apply internationally, due presumably to a lack of an international consensus on the subject. The advice from the National Radiological Protection Board, the College of Radiographers and the Royal College of Radiologists applies in the United Kingdom. In summary, the advice is that women of child bearing age are asked before a diagnostic radiology examination in which the pelvis is in, or near, the primary beam are asked if they are, or may be, pregnant. If pregnancy can be excluded then the examination can proceed. If it is likely that the patient is pregnant, then the proposed examination must undergo rigorous justification. If

  4. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  5. Medical Ethics in Radiology

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Park, Jae Hyung; Yoon, Soon Ho

    2010-01-01

    According to the recent developments in radiological techniques, the role of radiology in the clinical management of patients is ever increasing and in turn, so is the importance of radiology in patient management. Thus far, there have been few open discussions about medical ethics related to radiology in Korea. Hence, concern about medical ethics as an essential field of radiology should be part of an improved resident training program and patient management. The categories of medical ethics related with radiology are ethics in the radiological management of patient, the relationship of radiologists with other medical professionals or companies, the hazard level of radiation for patients and radiologists, quality assurance of image products and modalities, research ethics, and other ethics issues related to teleradiology and fusion imaging. In order to achieve the goal of respectful progress in radiology as well as minimizing any adverse reaction from other medical professions or society, we should establish a strong basis of medical ethics through the continuous concern and self education

  6. E-learning and education in radiology

    International Nuclear Information System (INIS)

    Pinto, Antonio; Brunese, Luca; Pinto, Fabio; Acampora, Ciro; Romano, Luigia

    2011-01-01

    Purpose: To evaluate current applications of e-learning in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Results: Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. Conclusion: E-learning will become an important source of education in radiology.

  7. E-learning and education in radiology.

    Science.gov (United States)

    Pinto, Antonio; Brunese, Luca; Pinto, Fabio; Acampora, Ciro; Romano, Luigia

    2011-06-01

    To evaluate current applications of e-learning in radiology. A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. E-learning will become an important source of education in radiology. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. E-learning and education in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Antonio, E-mail: antopin1968@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Brunese, Luca, E-mail: lucabrunese@libero.it [Department of Health Science, Faculty of Medicine and Surgery, University of Molise, I-86100 Campobasso (Italy); Pinto, Fabio, E-mail: fpinto1966@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Acampora, Ciro, E-mail: itrasente@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Romano, Luigia, E-mail: luigia.romano@fastwebnet.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy)

    2011-06-15

    Purpose: To evaluate current applications of e-learning in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Results: Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. Conclusion: E-learning will become an important source of education in radiology.

  9. Gonad Shielding for Patients Undergoing Conventional Radiological Examinations: Is There Cause for Concern?

    OpenAIRE

    Karami; Zabihzadeh; Gholami

    2016-01-01

    Background Gonad shielding is one of the fundamental methods by which to protect reproductive organs in patients undergoing conventional radiological examinations. A lack of or inadequate shielding of the gonads may increase the exposure of these organs and result in malignancies future generations. Objectives The aim of this study is to investigate the prevalence of gonad shielding in patients undergoing conventional radiological...

  10. The Development of Radiology among Slovenes

    Directory of Open Access Journals (Sweden)

    Zvonka Zupanič Slavec

    2016-10-01

    1993. The Clinical Radiology Institute, Ljubljana University Medical Centre, performs ambulatory and hospital radiological management at the secondary and tertiary levels for patients from the region of Ljubljana and from the rest of the country. A sophisticated radiology is also at the University Medical Centre Maribor. In the first decade of the 21st century radiology developed particularly quickly, bringing recent developments in international radiology to Slovenia, especially in the field of interventional radiology.

  11. Current evaluation of the information about Radiological Protection in Internet

    International Nuclear Information System (INIS)

    Ruiz-Cruces, R.; Marco, M.; Villanueva, I.

    2003-01-01

    To analyze the current situation about the pedagogic information on radiological protection training which could be found in Internet. More than 756 web-pages have been visited in Internet about Radiological Protection in the nuclear and medical fields, providing information mainly focusing on information to the members of the public. In this search were used internet Searching Appliance (as Copernicus, Google and Scirus), using key words related with this subject (as Radiological Protection and Health Safety), getting the internet address of organizations, societies and investigation groups. Only a low percentage (less than 5 per cent) of these addresses content information on Radiological Protection for the members of the public, including information about the regulator Organizations, and which are the objectives for protection of the members of the public against ionization radiation (from the point of view of the use of the ionization radiation in the medical and nuclear field). This work attempts to propose the use of internet as a tool for informing the members of the public in matter of radiological protection, as first link in the chain of the training and education. (Author)

  12. Subcutaneous granuloma annulare: radiologic appearance

    International Nuclear Information System (INIS)

    Kransdorf, M.J.; Murphey, M.D.; Temple, H.T.

    1998-01-01

    Objective. Granuloma annulare is an uncommon benign inflammatory dermatosis characterized by the formation of dermal papules with a tendency to form rings. There are several clinically distinct forms. The subcutaneous form is the most frequently encountered by radiologists, with the lesion presenting as a superficial mass. There are only a few scattered reports of the imaging appearance of this entity in the literature. We report the radiologic appearance of five cases of subcutaneous granuloma annulare. Design and patients. The radiologic images of five patients (three male, two female) with subcutaneous granuloma annulare were retrospectively studied. Mean patient age was 6.4 years (range, 2-13 years). The lesions occurred in the lower leg (two), foot, forearm, and hand. MR images were available for all lesions, gadolinium-enhanced imaging in three cases, radiographs in four, and bone scintigraphy in one. Results. Radiographs showed unmineralized nodular masses localized to the subcutaneous adipose tissue. The size range, in greatest dimension on imaging studies, was 1-4 cm. MR images show a mass with relatively decreased signal intensity on all pulse sequences, with variable but generally relatively well defined margins. There was extensive diffuse enhancement following gadolinium administration. Conclusion. The radiologic appearance of subcutaneous granuloma annulare is characteristic, typically demonstrating a nodular soft-tissue mass involving the subcutaneous adipose tissue. MR images show a mass with relatively decreased signal intensity on all pulse sequences and variable but generally well defined margins. There is extensive diffuse enhancement following gadolinium administration. Radiographs show a soft-tissue mass or soft-tissue swelling without evidence of bone involvement or mineralization. This radiologic appearance in a young individual is highly suggestive of subcutaneous granuloma annulare. (orig.)

  13. Quality management in a department of radiology

    International Nuclear Information System (INIS)

    Fischer, U.; Vosshenrich, R.; Baum, F.; Schorn, C.; Funke, M.; Grabbe, E.; Strasser, G.; Staudacher, J.

    2002-01-01

    Purpose. To increase the quality of internal and external interactions (patients, clinical colleagues, technicians, radiologists) in a department of radiology.Method. Accompanied by a well-experienced adviser workshops have been performed dealing with different topics like ''contact to patients'', ''performance of the radiological report and interaction with the referring colleague'' or ''research and teaching''. A catalogue of different actions was defined to reduce hindrances within the internal and external work-flow.Results. A total number of 53 actions was defined and related to different persons who were responsible for the realisation of the measures within a time interval. Six months after starting the quality management 46 (86%) of the defined actions were realised successfully, and another 4 (8%) measures were still running. There was a moderate increase of satisfaction of the patients and clinical colleagues considering the waiting time.Conclusions. A quality management in a radiological department allows an optimisation of the internal and external interactions. However, the guidance of a well-experienced adviser is as essential as the continuous control of successful finished measures. (orig.) [de

  14. Comparison of patient doses in interventional radiology procedures performed in two large hospitals in Greece

    International Nuclear Information System (INIS)

    Papageorgiou, E.; Tsapaki, V.; Tsalafoutas, I. A.; Maurikou, E.; Kottou, S.; Orfanos, A.; Karidas, G.; Fidanis, T.; Zafiriadou, E.; Neofotistou, V.

    2007-01-01

    Purpose of the study was to determine patient doses in the most common interventional radiology (IR) procedures performed in two large Greek hospitals. A total of 164 patients who underwent 4 types of IR procedures were studied. Fluoroscopy time, total exposure time, number of frames, number of runs, radiation field size, and cumulative dose-area product (DAP) were recorded. The median DAP values for carotid arteriography and lower limb arteriography were 66 and 123 Gy cm 2 for hospital 'A' and 21 and 49 Gy cm 2 for hospital 'B'. For the cerebral arteriographies performed in hospital 'A', the median DAP was 116 Gy cm 2 while for the hepatic embolizations performed in hospital 'B', it was 104 Gy cm 2 . The DAP values observed in hospital 'A' for carotid arteriography and lower limb arteriography were almost three times than those of hospital 'B'. From the data analysis, it is evident that dose optimization in hospital 'A' should be pursued through revision of the techniques used. (authors)

  15. Experimental Design and Data Analysis in Receiver Operating Characteristic Studies: Lessons Learned from Reports in Radiology from 1997 to 20061

    Science.gov (United States)

    Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio

    2009-01-01

    Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510

  16. Basic demands for radiological information systems (RIS)

    International Nuclear Information System (INIS)

    Traupe, H.; Purgold, S.

    1993-01-01

    One of the most important problems in medicine today is quality control and the achievement of a cost-benefit analysis in the areas of both treatment and diagnosis. With modern software techniques, complex relations between medical and aministrative data can be shown up and analysed. Preconditions are a vocabulary that can be processed by computer for medical facts and decisions and a database system capable of collecting a large amount of heterogeneous data and costing everything precisely. We have developed an object description language and, on the basis of the relational database approach, a complex system covering most aspects of medical and administrative data handling in radiology. The basic demands and elements of modern information handling in radiology are described and discussed. (orig.) [de

  17. Radiological protection of the environment from an NGO perspective

    International Nuclear Information System (INIS)

    Carroll, S.

    2008-01-01

    Non-governmental environmental organisations (environmental NGOs) may consider the issue of radiological protection of the environment differently to other interested parties such as regulators or industry. While environmental NGOs are broadly positive towards the current emphasis and engagement on radiological protection of the environment per se, there remain concerns about the precise meaning of the term and the ultimate objectives of the current initiatives. Various strategies are studied and discussed. The disposal of radioactive waste at sea is discussed and a case study presented. What the environmental NGOs are looking for is focused upon and various environmental protection systems are discussed (tk)

  18. Oil wells and gas wells: aspects of radiological safety

    International Nuclear Information System (INIS)

    Soares, S.M.V.O.

    1987-01-01

    The objective of the present work is to present and analyse the main radiological protection problems associated with non destructive inspections of oil wells, with the view of minimizing the dose to members of the public living in nearby urban zones. Problems related to the surveillance of such activities and the need for well formulated procedures are also discussed based on specific Brasilian regulations. Finally, some examples of radiological accidents that have occured in urban zones are described including the methodology employed for the rescue of Iridium-192 sources and for the estimate of radiation doses for workers and general public. (author) [pt

  19. Magnitudes and units in the X-ray dosimetry in diagnostic radiology

    International Nuclear Information System (INIS)

    Tovar M, V. M.; Cejudo A, J.; Vergara M, F.

    2009-10-01

    The dosimetry objective in the radiological image is the quantification from the exposition to the radiation with a commitment of optimizing the image quality to the reason of the absorbed dose. The dosimetry has the meaning of avoiding excessive dose that could imply a significant risk of deterministic effects induction. The dosimetric magnitudes and dosimetry protocols in the radiological image, are those that are related to the risks for the patient. Exist in diagnostic radiology two fundamentals reason to measure or to estimate the patient radiation dose. First, the mensurations are a means to verify the good practices and an aid to the optimization of the patient protection. Second, the absorbed dose estimation to tissues and organs in the patient are necessary to determine the risks, and this way to indicate that the radiological techniques employees can be justified and in investigated cases of over exposition. (Author)

  20. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal A.; Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dwyer, Kathy; Yu-Moe, Winnie [CRICO Risk Management Foundation, Boston, MA (United States)

    2017-06-15

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality

  1. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    International Nuclear Information System (INIS)

    Breen, Micheal A.; Taylor, George A.; Dwyer, Kathy; Yu-Moe, Winnie

    2017-01-01

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality implicated in

  2. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims.

    Science.gov (United States)

    Breen, Micheál A; Dwyer, Kathy; Yu-Moe, Winnie; Taylor, George A

    2017-06-01

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality implicated in

  3. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  4. Radiological safety by design

    International Nuclear Information System (INIS)

    Gundaker, W.E.

    1977-01-01

    Under the Radiation Control for Health and Safety Act enacted by the U.S. Congress in 1968, the Food and Drug Administration's Bureau of Radiological Health may prescribe performance standards for products that emit radiation. A description is given of the development of these standards and outlines the administrative procedures by which they are enforced. (author)

  5. Radiological Assessment Of The Uterus And Fallopian Tubes In ...

    African Journals Online (AJOL)

    Objectives: This study is aimed at determining the pattern of abnormalities in the Hysterosalpingograms of patients who attended the Radiology Unit of Ebonyi State University Teaching Hospital, Abakaliki. Method: The 188 hysterosalpingograms conducted between January 2002 to December 2005 were analysed. Results: ...

  6. Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment

    International Nuclear Information System (INIS)

    MANN, F.M.

    1999-01-01

    Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a, DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a, DOE 1999a) require (see Appendix B): The protection of public health and safety; and The protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mredyear), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments; interacting with program management to establish the additional requirements of the program; and interacting with the public (i.e., the Hanford Advisory Board members; as well as affected Tribal Governments) to understand the values of residents in the Pacific Northwest. Because of space considerations, not all radionuclides and dangerous chemicals are listed in this document. The radionuclides listed here are those which were explicitly treated in the ILAW PA (Mann 1998). The dangerous chemicals listed here are those most often detected in Hanford tank waste as documented in the Regulatory Data Quality Objectives Supporting Tank Waste Remediation System Privatization Project (Wiemers 1998)

  7. A model to determine payments associated with radiology procedures.

    Science.gov (United States)

    Mabotuwana, Thusitha; Hall, Christopher S; Thomas, Shiby; Wald, Christoph

    2017-12-01

    Across the United States, there is a growing number of patients in Accountable Care Organizations and under risk contracts with commercial insurance. This is due to proliferation of new value-based payment models and care delivery reform efforts. In this context, the business model of radiology within a hospital or health system context is shifting from a primary profit-center to a cost-center with a goal of cost savings. Radiology departments need to increasingly understand how the transactional nature of the business relates to financial rewards. The main challenge with current reporting systems is that the information is presented only at an aggregated level, and often not broken down further, for instance, by type of exam. As such, the primary objective of this research is to provide better visibility into payments associated with individual radiology procedures in order to better calibrate expense/capital structure of the imaging enterprise to the actual revenue or value-add to the organization it belongs to. We propose a methodology that can be used to determine technical payments at a procedure level. We use a proportion based model to allocate payments to individual radiology procedures based on total charges (which also includes non-radiology related charges). Using a production dataset containing 424,250 radiology exams we calculated the overall average technical charge for Radiology to be $873.08 per procedure and the corresponding average payment to be $326.43 (range: $48.27 for XR and $2750.11 for PET/CT) resulting in an average payment percentage of 37.39% across all exams. We describe how charges associated with a procedure can be used to approximate technical payments at a more granular level with a focus on Radiology. The methodology is generalizable to approximate payment for other services as well. Understanding payments associated with each procedure can be useful during strategic practice planning. Charge-to-total charge ratio can be used to

  8. A pilot study of radiation exposures arising from interventional radiology procedures

    International Nuclear Information System (INIS)

    Pellet, S.; Giczi, F.; Gaspardy, G.; Temesi, A.; Ballay, L.

    2006-01-01

    Full text of publication follows: In the past 25 years, considerable number of new therapeutic procedures have been worked out and adopted in radiology. These interventional procedures are mainly based on angiographic methods. During these procedures the exposure of patients and staff are usually greater than of conventional radiography and fluoroscopy as a consequence of longer fluoroscopy times and great number of cine-radiography. In the latest years radiation-induced skin injuries occurred in some patients. Injuries to physicians and staff performing interventional procedures have also been observed. In our days interventional procedures are widely used and more sophisticated procedures are worked out and adopted. Consequently, there is a need for the protection of the patient and the staff on a higher level. Radiation protection of intervention radiology deserves a distinguish attention. In Hungary interventional radiology were performed in 36 laboratories in 2003. According to statistical data the gross number of interventional radiological procedures were 19442. The most frequently performed procedures were the P.T.C.A., the coronary and ilio-femoral stent implantation and chemo-embolization. In 2004, the National Research Institute for Radiobiology and Radio-hygiene and the National Patient Dose Evaluation Program started a pilot study of radiation exposures arising from interventional radiology procedures. During the study the patient exposure were measured by D.A.P.-meters. The patient skin dose and the staff dose were performed by thermoluminescent chips. In their presentation the authors present the most important results of the study. (authors)

  9. Natural Language Processing in Radiology: A Systematic Review.

    Science.gov (United States)

    Pons, Ewoud; Braun, Loes M M; Hunink, M G Myriam; Kors, Jan A

    2016-05-01

    Radiological reporting has generated large quantities of digital content within the electronic health record, which is potentially a valuable source of information for improving clinical care and supporting research. Although radiology reports are stored for communication and documentation of diagnostic imaging, harnessing their potential requires efficient and automated information extraction: they exist mainly as free-text clinical narrative, from which it is a major challenge to obtain structured data. Natural language processing (NLP) provides techniques that aid the conversion of text into a structured representation, and thus enables computers to derive meaning from human (ie, natural language) input. Used on radiology reports, NLP techniques enable automatic identification and extraction of information. By exploring the various purposes for their use, this review examines how radiology benefits from NLP. A systematic literature search identified 67 relevant publications describing NLP methods that support practical applications in radiology. This review takes a close look at the individual studies in terms of tasks (ie, the extracted information), the NLP methodology and tools used, and their application purpose and performance results. Additionally, limitations, future challenges, and requirements for advancing NLP in radiology will be discussed. (©) RSNA, 2016 Online supplemental material is available for this article.

  10. Radiology in Medical Education: A Pediatric Radiology Elective as a Template for Other Radiology Courses.

    Science.gov (United States)

    Hilmes, Melissa A; Hyatt, Eddie; Penrod, Cody H; Fleming, Amy E; Singh, Sudha P

    2016-03-01

    Traditionally, the pediatric radiology elective for medical students and pediatric residents constituted a morning teaching session focused mainly on radiography and fluoroscopy. A more structured elective was desired to broaden the exposure to more imaging modalities, create a more uniform educational experience, and include assessment tools. In 2012, an introductory e-mail and formal syllabus, including required reading assignments, were sent to participants before the start date. A rotating weekly schedule was expanded to include cross-sectional imaging (ultrasound, CT, MR) and nuclear medicine. The schedule could accommodate specific goals of the pediatric resident or medical student, as requested. Starting in 2013, an online pre-test and post-test were developed, as well as an online end-of-rotation survey specific to the pediatric radiology elective. Taking the Image Gently pledge was required. A scavenger hunt tool, cue cards, and electronic modules were added. Pre-test and post-test scores, averaged over 2 years, showed improvement in radiology knowledge, with scores increasing by 27% for medical students and 21% for pediatric residents. Surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. We have successfully created an elective experience in radiology that dedicates time to education while preserving the workflow of radiologists. We have developed tools to provide a customized experience with many self-directed learning opportunities. Our tools and techniques are easily translatable to a general or adult radiology elective. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. An automated radiological survey method for performing site remediation and decommissioning

    International Nuclear Information System (INIS)

    Handy, R.G.; Bolch, W.E.; Harder, G.F.; Tolaymat, T.M.

    1994-01-01

    A portable, computer-based method of performing environmental monitoring and assessment for site remediation and decommissioning has been developed. The integrated system has been developed to provide for survey time reductions and real-time data analysis. The technique utilizes a notebook 486 computer with the necessary hardware and software components that makes it possible to be used in an almost unlimited number of environmental monitoring and assessment scenarios. The results from a pilot, open-quotes hide-and-seekclose quotes gamma survey and an actual alpha decontamination survey were elucidated. It was found that a open-quotes hide-and-seekclose quotes survey could come up with timely and accurate conclusions about the position of the source. The use of the automated system in a Th-232 alpha survey resulted in a reduction in the standard time necessary to do a radiological survey. In addition, the ability to analyze the data on-site allowed for identification and location of areas which needed further decontamination. Finally, a discussion on possible future improvements and field conclusions was made

  12. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    International Nuclear Information System (INIS)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-01-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  13. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games.

    Science.gov (United States)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-10-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9% were magnetic resonance imaging (MRI) scans, 22% were diagnostic ultrasound (US) examinations, 33.1% were radiographs, 4.3% were computed tomography (CT) scans and 2.7% were imaging-guided interventional procedures. 88% of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events.

  14. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    Energy Technology Data Exchange (ETDEWEB)

    Bethapudi, Sarath [County Durham Darlington Foundation NHS Trust, Durham (United Kingdom); Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Ritchie, David [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Greater Glasgow and Clyde Hospitals NHS Trust, Western Infirmary, Glasgow (United Kingdom); Bongale, Santosh [Glasgow 2014 Commonwealth Games, Immediate Care Department, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Royal Alexandra Hospital, Paisley (United Kingdom); Gordon, Jonny [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Glasgow (United Kingdom); MacLean, John [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); National Stadium Sports Medicine Centre, Glasgow (United Kingdom); Mendl, Liz [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom)

    2015-10-15

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  15. Chest radiological findings in pakistani cement mill workers

    International Nuclear Information System (INIS)

    Meo, Sultan A.

    2003-01-01

    Chest radiological findings in Pakistani cement mill workers Even in the 21st century, in developing countries millions of people work daily in dusty environments. They are exposed to different types of health hazards namely, fumes, gases and dust, which are risk factors for developing occupational diseases. Therefore, the aim of this study was to perform chest radiology to determine the occupational hazards of cement dust on the lungs of cement mill workers. This study was carried out in the Department of Physiology, Faculty of Health and Medical Sciences, Hamdard University Karachi, Pakistan, during the period June to August 2000. In this study 50, apparently healthy volunteer male cement mill workers were randomly selected with an average of 13 years exposure with age ranging from 20-60 years. They were matched with 50, healthy male control subjects in terms of age, height, weight and socioeconomic status. Both groups met with exclusion criteria as per standard. Radiology was performed by Trophy radiology. Results: The present study demonstrated 12% of cases with interstitial lung disease and 2% of cases with pleural thickening and chronic bronchitis in cement mill workers. Conclusion: Exposure to cement dust causes interstitial lung disease, pleural thickening and chronic bronchitis in cement mill workers. (author)

  16. Quantitative computed tomography (QCT) as a radiology reporting tool by using optical character recognition (OCR) and macro program.

    Science.gov (United States)

    Lee, Young Han; Song, Ho-Taek; Suh, Jin-Suck

    2012-12-01

    The objectives are (1) to introduce a new concept of making a quantitative computed tomography (QCT) reporting system by using optical character recognition (OCR) and macro program and (2) to illustrate the practical usages of the QCT reporting system in radiology reading environment. This reporting system was created as a development tool by using an open-source OCR software and an open-source macro program. The main module was designed for OCR to report QCT images in radiology reading process. The principal processes are as follows: (1) to save a QCT report as a graphic file, (2) to recognize the characters from an image as a text, (3) to extract the T scores from the text, (4) to perform error correction, (5) to reformat the values into QCT radiology reporting template, and (6) to paste the reports into the electronic medical record (EMR) or picture archiving and communicating system (PACS). The accuracy test of OCR was performed on randomly selected QCTs. QCT as a radiology reporting tool successfully acted as OCR of QCT. The diagnosis of normal, osteopenia, or osteoporosis is also determined. Error correction of OCR is done with AutoHotkey-coded module. The results of T scores of femoral neck and lumbar vertebrae had an accuracy of 100 and 95.4 %, respectively. A convenient QCT reporting system could be established by utilizing open-source OCR software and open-source macro program. This method can be easily adapted for other QCT applications and PACS/EMR.

  17. Evaluation of radiological medical practice during night duty

    International Nuclear Information System (INIS)

    Tasu, J.P.; Rocher, L.; Miquel, A.; Rondeau, Y.; Blery, M.; Nguyen, D.T.; Spira, A.; Livartowski, J.; Ellrodt, A.

    2000-01-01

    To evaluate the radiological activity during night duty, in a University Hospital, during 100 days, the radiological activity has been evaluated from examinations requiring radiologist (including US and CT, special X-ray examinations). The urgent nature and the agreement between the suspected disease and the final diagnose have been compared with the level of the clinician (medical student, resident, senior). 981 radiological examinations were performed on an emergency basis. In 39%, the examination was urgent or very urgent and for 61% little urgent or non-urgent. The level of the clinician was correlated with the degree of emergency evaluated by the radiologist and with the agreement between suspected disease and the final diagnose (p<0.0001). During night duty, the medical activity in radiology is not justified only be emergency, but also the continuous hospital activities. Better formation of the physician is required to limit the number of examinations. (authors)

  18. Analysis of operation TEAPOT nuclear test ZUCCHINI radiological and meterological data

    International Nuclear Information System (INIS)

    Quinn, V.E.

    1987-03-01

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the ZUCCHINI nuclear test of Operation TEAPOT. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time and estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed in the 1950's is presented. The radiological data used to derive the WSNSO 1986 fallout pattern are tabulated in an appendix

  19. Study on the action guidelines for medical support team for nuclear and radiological emergency

    International Nuclear Information System (INIS)

    Liu Chang'an; Liu Ying; Geng Xiusheng

    2006-01-01

    Objective: To study the action guidelines for medical support team for nuclear and radiological emergency. Methods: It is based on the experience and lessons learned in the course of meeting the emergencies preparedness and response of nuclear and radiological emergencies in China and abroad with the reference of the relevant reports of International Atomic Energy Agency. Results: Essential requirements and practical recommendations for the roles, responsibilities, emergency preparedness, principles and procedures of medical assistance at the scene, as well as the radiological protection of medical support team were provided. Conclusion: The document mentioned above can be applied to direct the establishment, effective medical preparedness and response of the medical support team for nuclear and radiological emergency. (authors)

  20. Radiological assessment of the Rhone valley. Final report related to the ground environment

    International Nuclear Information System (INIS)

    Roussel-Debet, S.; Saey, L.; Mourier, D.; Salaun, G.

    2012-01-01

    This report presents and comments the results obtained during a ground radiological survey performed in the Rhone valley from May 2009 to end of 2011. It recalls the general sampling and analysis strategy, in terms of objectives, locations, samples to measure tritium and carbon 14, and specific samples. It presents and discusses results obtained for tritium and carbon 14, and notably measurements obtained in boar meat. Other commented results are those obtained by gamma spectrometry on farm products (measurements of natural and artificial radionuclides), by analysis of milk products, and by specific samplings and analysis (bio-indicators in the vicinity of Marcoule, Camargue sands and beaches, rice field grounds, measurements performed after the Fukushima accident)

  1. Telemetry of Aerial Radiological Measurements

    International Nuclear Information System (INIS)

    Clark, H. W. Jr.

    2002-01-01

    Telemetry has been added to National Nuclear Security Administration's (NNSA's) Aerial Measuring System (AMS) Incident Response aircraft to accelerate availability of aerial radiological mapping data. Rapid aerial radiological mapping is promptly performed by AMS Incident Response aircraft in the event of a major radiological dispersal. The AMS airplane flies the entire potentially affected area, plus a generous margin, to provide a quick look at the extent and severity of the event. The primary result of the AMS Incident Response over flight is a map of estimated exposure rate on the ground along the flight path. Formerly, it was necessary to wait for the airplane to land before the map could be seen. Now, while the flight is still in progress, data are relayed via satellite directly from the aircraft to an operations center, where they are displayed and disseminated. This permits more timely utilization of results by decision makers and redirection of the mission to optimize its value. The current telemetry capability can cover all of North America. Extension to a global capability is under consideration

  2. Infant manual performance during reaching and grasping for objects moving in depth.

    Science.gov (United States)

    Domellöf, Erik; Barbu-Roth, Marianne; Rönnqvist, Louise; Jacquet, Anne-Yvonne; Fagard, Jacqueline

    2015-01-01

    Few studies have investigated manual performance in infants when reaching and grasping for objects moving in directions other than across the fronto-parallel plane. The present preliminary study explored object-oriented behavioral strategies and side preference in 8- and 10-month-old infants during reaching and grasping for objects approaching in depth from three positions (midline, and 27° diagonally from the left and right). Effects of task constraint by using objects of three different types and two sizes were further examined for behavioral strategies and hand opening prior to grasping. Additionally, assessments of hand preference by a dedicated handedness test were performed. Regardless of object starting position, the 8-month-old infants predominantly displayed right-handed reaches for objects approaching in depth. In contrast, the older infants showed more varied strategies and performed more ipsilateral reaches in correspondence with the side of the approaching object. Conversely, 10-month-old infants were more successful than the younger infants in grasping the objects, independent of object starting position. The findings regarding infant hand use strategies when reaching and grasping for objects moving in depth are similar to those from earlier studies using objects moving along a horizontal path. Still, initiation times of reaching onset were generally long in the present study, indicating that the object motion paths seemingly affected how the infants perceived the intrinsic properties and spatial locations of the objects, possibly with an effect on motor planning. Findings are further discussed in relation to future investigations of infant reaching and grasping for objects approaching in depth.

  3. Radiological characterization of a relevant facility

    International Nuclear Information System (INIS)

    Barberis, Claudia M.; Madariaga, Marcelo

    2009-01-01

    The objective of this work is the radiological characterization of a Nuclear Installation, the RA-1 nuclear reactor. By means of this characterization all the information about amount, type and distribution of radionuclides in the installation will be available. Thus the order of magnitude of the activities that will be involved in the removal of the different materials, at the moment of the decommissioning, will be established. (author)

  4. Study of physical, chemical and radiological characteristic of thermal water

    International Nuclear Information System (INIS)

    Labidi, Saleem

    2004-01-01

    Hydrotherapy is an activity during which the practitioner is exposed to natural ionising radiation. Radon from deep geological layers constitutes the praincipal irradiation factor for the worker and the patient. The study of radiological impact requires specific measurements that should be compared with international commission of radiological protection (ICRP) recommendations. The objective of this study is to estimate the health risk for employees and patients in hydrotherapy spas in tunisia, by calculating the annual effective dose within the diffrent sites, to identify the sites that could present a hasard from radon and to establish a protection scheme for on workers in these spas. This study is performed inside of the tunisian thermal spas. It consists in separating 226 Ra and measuring its concentration in the thermal water of each spa and then, determining the radon concentration with solid state track detectors (SSTD) chosen for their sensitivity to alpha particles. The dose assessment results show that the estimates values were lower than the ICRP recommendations. In addition, the effective doses received by the workers are greater than those received by the patients due to the longer exposure time for the workers. (author). 79 refs 6)

  5. Radiation risks management during implementation of activities at the 'Ukryttia' object

    International Nuclear Information System (INIS)

    Batij, V.G.; Rubezhanskij, Yu.I.; Rud'ko, V.M.; Stoyanov, A.I.

    2002-01-01

    A methodology for assessment and analysis of radiological risks occurring in the course of activities aimed at 'Ukryttia' Object operation and conversion was developed, as well as general scheme of risks management was prepared. The priority measures that are to be realized in order to create an effective system of radiological risks management at the 'Ukryttia' were proposed

  6. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453

    International Nuclear Information System (INIS)

    Costa, Rogerio Ferreira da

    2013-01-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  7. Ewing sarcoma of the foot. Radiological findings

    International Nuclear Information System (INIS)

    Albisinni, U.; Capanna, R.; Nigrisoli, M.

    1987-01-01

    Ewing's Sarcoma (ES) is the most frequent malignant bone tumor of the foot. The radiological picture is characterized, in 14 patients, by a pure osteolytic lesion (9 cases) or by a mixed one (5 cases); the interruption of the cortical bone and swelling of the soft tissues were always present; the periostal reaction was occasional. The radiological aspects cannot be considered typical of the ES and it is suggested that biopsies should always be performed in the presence of structural alteration of the bone

  8. Radiological profile of pulmonary tuberculosis in HIV: concerning 171 observations in Kinshasa

    International Nuclear Information System (INIS)

    Djamba, O.N.; Mukaya, J.; Kayembe, J.M.

    2011-01-01

    This prospective descriptive study was conducted in Depistage center of the Tuberculosis treatment of Kabinda during a period of three months, had as objectives to study the radiological profile of pulmonary tuberculosis in HIV and HIV- patients, then to compare the frequency of different radiological abnormalities between the two groups to determine some characteristics of co-infection HIV/TP+. Among 171 patients with contagious pulmonary tuberculosis, 50 patients had positive serology for HIV, a prevalence of 29,2%. The intrathoracic lymph nodes, localized lesions only in the lower field were more observed in HIV, as well as pleurisy and the absence of radiological abnormality. The only one case of miliary was HIV positive. By contrast, excavations and localized lesions in the upper field were predominant in HIV-. Atypical radiological manifestations of pulmonary tuberculosis were more common in patients with HIV infection.

  9. Approaching the Practice Quality Improvement Project in Interventional Radiology.

    Science.gov (United States)

    Reis, Stephen P; White, Benjamin; Sutphin, Patrick D; Pillai, Anil K; Kalva, Sanjeeva P; Toomay, Seth M

    2015-12-01

    An important component of maintenance of certification and quality improvement in radiology is the practice quality improvement (PQI) project. In this article, the authors describe several methodologies for initiating and completing PQI projects. Furthermore, the authors illustrate several tools that are vital in compiling, analyzing, and presenting data in an easily understandable and reproducible manner. Last, they describe two PQI projects performed in an interventional radiology division that have successfully improved the quality of care for patients. Using the DMAIC (define, measure, analyze, improve, control) quality improvement framework, interventional radiology throughput has been increased, to lessen mediport wait times from 43 to 8 days, and mediport infection rates have decreased from more than 2% to less than 0.4%. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Subspecialisation in Emergency Radiology: Proposal for a harmonised European curriculum

    Directory of Open Access Journals (Sweden)

    Wagner, M. G.

    2017-11-01

    Full Text Available Introduction: Radiology plays a crucial role in the emergency care setting by delivering early and precise diagnoses under pressure of time, right at the beginning of patient treatment. Although there is a need for postgraduate education in emergency radiology, most of the national bodies responsible do not offer it in a uniform fashion and a general proof of qualification is missing in Europe. Therefore, the European Society of Radiology (ESR has founded the (Sub-Society of Emergency Radiology (ESER, prompting them to develop a European curriculum. This trend, which is currently also encouraged in many other non-radiological specialties which demand the highest professional qualifications, often lacks expertise in medical education.Goals: The goal of this article is the general description of the curricular planning process for a European postgraduate subspecialisation programme, using the example of Emergency Radiology (European Diploma in Emergency Radiology, EDER, including the utilisation of TOOLS and recommendations derived from comparable projects.Project description: The project was divided into partial steps: the timeline displayed in a GANTT chart, and tasks and responsibilities assigned in a RASCI matrix. The curriculum was iteratively developed using the KERN approach and steps were prioritised using the PARETO principle. Furthermore, the following TOOLS were used: limitations and needs assessment, SWOT analysis, formulating learning objectives and categorising them after MILLER and SCLO, and using BLOOM’s taxonomy for cognitive learning objectives and operationalising them according to MAGER. Psychomotoric and affective learning objectives were assigned to CANMEDS roles, grouped by topic using CLUSTERING, and then mapped by MATRIX analysis to appropriate learning and evaluation methods. Striving for continuous improvement, the curriculum was finally embedded in curricular quality management.Results: The standardisation of the EDER

  11. Subspecialisation in Emergency Radiology: Proposal for a harmonised European curriculum

    Science.gov (United States)

    Wagner, M. G.; Fischer, M. R.; Scaglione, M.; Linsenmaier, U.; Schueller, G.; Berger, F. H.; Dick, E.; Basilico, R.; Stajgis, M.; Calli, C.; Vaidya, S.; Wirth, Stefan

    2017-01-01

    Introduction: Radiology plays a crucial role in the emergency care setting by delivering early and precise diagnoses under pressure of time, right at the beginning of patient treatment. Although there is a need for postgraduate education in emergency radiology, most of the national bodies responsible do not offer it in a uniform fashion and a general proof of qualification is missing in Europe. Therefore, the European Society of Radiology (ESR) has founded the (Sub-)Society of Emergency Radiology (ESER), prompting them to develop a European curriculum. This trend, which is currently also encouraged in many other non-radiological specialties which demand the highest professional qualifications, often lacks expertise in medical education. Goals: The goal of this article is the general description of the curricular planning process for a European postgraduate subspecialisation programme, using the example of Emergency Radiology (European Diploma in Emergency Radiology, EDER), including the utilisation of TOOLS and recommendations derived from comparable projects. Project description: The project was divided into partial steps: the timeline displayed in a GANTT chart, and tasks and responsibilities assigned in a RASCI matrix. The curriculum was iteratively developed using the KERN approach and steps were prioritised using the PARETO principle. Furthermore, the following TOOLS were used: limitations and needs assessment, SWOT analysis, formulating learning objectives and categorising them after MILLER and SCLO, and using BLOOM’s taxonomy for cognitive learning objectives and operationalising them according to MAGER. Psychomotoric and affective learning objectives were assigned to CANMEDS roles, grouped by topic using CLUSTERING, and then mapped by MATRIX analysis to appropriate learning and evaluation methods. Striving for continuous improvement, the curriculum was finally embedded in curricular quality management. Results: The standardisation of the EDER access

  12. A practical approach to radiation protection information in diagnostic radiology

    International Nuclear Information System (INIS)

    Cederblad, Aa.; Bjurklint, E.; Maansson, L.G.; Sund, P.; Kheddache, S.

    1999-01-01

    In a benchmarking process, parameters related to patient doses and image quality were compared in x-ray examinations from 10 radiology departments in western Sweden. One main object of the project was to form a pedagogical process focussing on radiation protection and quality matters by engaging radiographers and radiologists from the departments in practical project work and optimisation discussions. Anatomical phantoms with simulated pathology were used for standardised entrance dose measurements and exposure of phantom images. Radiographer performance, such as centering and collimation, was evaluated by radiographers. Radiologists evaluated clinical images using revised CEC quality criteria. The results of the measurements showed significant differences between the departments both for image quality, entrance dose and the performance of examinations. Explanations to these differences were in many cases found in the choice of equipment, working methods etc. (au)

  13. Radiological planning and implementation for nuclear-facility decommissioning

    International Nuclear Information System (INIS)

    Valentine, A.M.

    1982-01-01

    The need and scope of radiological planning required to support nuclear facility decommissioning are issues addressed in this paper. The role of radiation protection engineering and monitoring professionals during project implementation and closeout is also addressed. Most of the discussion focuses on worker protection considerations; however, project support, environmental protection and site release certification considerations are also covered. One objective is to identify radiological safety issues that must be addressed. The importance of the issues will vary depending on the type of facility being decommissioned; however, by giving appropriate attention to these issues difficult decommissioning projects can be accomplished in a safer manner with workers and the public receiving minimal radiation exposures

  14. Information extraction from multi-institutional radiology reports.

    Science.gov (United States)

    Hassanpour, Saeed; Langlotz, Curtis P

    2016-01-01

    also evaluated the generalizability of our approach across different organizations by training and testing our system on data from different organizations. Our results show the efficacy of our machine learning approach in extracting the information model's elements (10-fold cross-validation average performance: precision: 87%, recall: 84%, F1 score: 85%) and its superiority and generalizability compared to the common non-machine learning approach (p-valueinformation extraction approach provides an effective automatic method to annotate and extract clinically significant information from a large collection of free text radiology reports. This information extraction system can help clinicians better understand the radiology reports and prioritize their review process. In addition, the extracted information can be used by researchers to link radiology reports to information from other data sources such as electronic health records and the patient's genome. Extracted information also can facilitate disease surveillance, real-time clinical decision support for the radiologist, and content-based image retrieval. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Radiology systems architecture.

    Science.gov (United States)

    Deibel, S R; Greenes, R A

    1996-05-01

    This article focuses on the software requirements for enterprise integration in radiology. The needs of a future radiology systems architecture are examined, both at a concrete functional level and at an abstract system-properties level. A component-based approach to software development is described and is validated in the context of each of the abstract system requirements for future radiology computing environments.

  16. Participation of the ININ in the external radiological emergency plan of the Laguna Verde power plant

    International Nuclear Information System (INIS)

    Martinez S, R.; Cervini L, A.

    1991-01-01

    The planning of performances in radiological emergencies, with the object of reducing the consequences as much as possible on the population to accidental liberations of radioactive material coming from Nuclear power plant, it has been of main interest in the nuclear community in the world. In Mexico it has not been the exception, since with the setting in march of the Laguna Verde nuclear power plant exists an executive program of planning for emergencies that it outlines the activities to follow trending to mitigate the consequences that are derived of this emergency. As integral part of this program this the External Plan of Radiological Emergency (PERE) that covers the emergencies that could leave the frontiers of the Laguna Verde power plant. In the PERE it settles down the planning, address and control of the preparation activities, response and recovery in emergencies, as well as the organization and coordination of the institutions that participate. The National Institute of Nuclear Research (ININ), like integral part of these institutions in the PERE, has an infrastructure that it allows to participate in the plan in a direct way in the activities of 'Control of the radiological exhibition the response personnel and control of water and foods' and of support way and consultant ship in the activities of 'Monitoring, Classification and decontamination of having evaluated' and 'Specialized medical radiological attention'. At the moment the ININ has a radiological mobile unit and this conditioning a second mobile unit to carry out part of the activities before mentioned; also accounts with 48 properly qualified people that directly intervene in the plan. In order to guarantee an adequate response in the PERE an organization it has been structured like that of the annex as for the personnel, transport, team, procedures and communication system, with the objective always of guaranteeing the security and the population's health in emergency situations in the

  17. Evaluation of Subjective and Objective Performance Metrics for Haptically Controlled Robotic Systems

    Directory of Open Access Journals (Sweden)

    Cong Dung Pham

    2014-07-01

    Full Text Available This paper studies in detail how different evaluation methods perform when it comes to describing the performance of haptically controlled mobile manipulators. Particularly, we investigate how well subjective metrics perform compared to objective metrics. To find the best metrics to describe the performance of a control scheme is challenging when human operators are involved; how the user perceives the performance of the controller does not necessarily correspond to the directly measurable metrics normally used in controller evaluation. It is therefore important to study whether there is any correspondence between how the user perceives the performance of a controller, and how it performs in terms of directly measurable metrics such as the time used to perform a task, number of errors, accuracy, and so on. To perform these tests we choose a system that consists of a mobile manipulator that is controlled by an operator through a haptic device. This is a good system for studying different performance metrics as the performance can be determined by subjective metrics based on feedback from the users, and also as objective and directly measurable metrics. The system consists of a robotic arm which provides for interaction and manipulation, which is mounted on a mobile base which extends the workspace of the arm. The operator thus needs to perform both interaction and locomotion using a single haptic device. While the position of the on-board camera is determined by the base motion, the principal control objective is the motion of the manipulator arm. This calls for intelligent control allocation between the base and the manipulator arm in order to obtain intuitive control of both the camera and the arm. We implement three different approaches to the control allocation problem, i.e., whether the vehicle or manipulator arm actuation is applied to generate the desired motion. The performance of the different control schemes is evaluated, and our

  18. Extracorporeal shock wave lithotripsy: Involvement and impact on radiology at a kidney stone center

    International Nuclear Information System (INIS)

    Cochran, S.T.; Barbaric, Z.L.; Mindell, H.; Chaussy, C.D.; Fuchs, G.J.

    1986-01-01

    Of 1,222 extracorporeal shock wave lithotripsy (ECSW) procedures performed on 925 patients (600 males, 325 females), 85% were unilateral and 35% were bilateral treatments. Treated were 446 calyceal, 345 pelvic, 172 uretral, and 108 staghorn calculi. The impact of this new technology to the radiology department was studied. An average of 6.3 KUB studies and 1.2 renal US studies were performed per treatment session. Six percent of patients required post-ESWL excretory urography of CT; 10% required percutaneous nephrostomy. Patients with treated staghorn calculi required the most radiologic procedures (34% performed for partial staghorn calculi, 56% for complete staghorn calculi). By comparison, 3%, 8%, and 11% of radiologic procedures were performed for calyceal, pelvic, and ureteral stones, respectively. The impact of ESWL on the radiology department can be substantial. When staghorn calculi are treated by ESWL, a radiologist skilled in interventional techniques is essential

  19. New era of the relationship between Chinese interventional radiology sub-society and journal of interventional radiology

    International Nuclear Information System (INIS)

    Li Linsun

    2009-01-01

    The past decades have witnessed interventional radiology in China to go from a very initial clinical practice to an important medical player in modern medicine. Recently, a friendly collaboration has been successfully established between the Chinese Interventional Radiology Sub-society and the Journal of Interventional Radiology. The Chinese Interventional Radiology Sub-society will take the full responsibility for the academic governance of the Journal of Interventional Radiology and the Journal of Interventional Radiology will formally become the sole interventional academic periodical of the Chinese Interventional Radiology Sub-society in China. This collaboration will surely make Chinese interventional radiology to initiate a new era,promote the further development of interventional radiology at home and enable the Journal of Interventional Radiology to step into the international medical circle. (authors)

  20. Review of IAEA documentation on Nuclear and radiological emergency

    International Nuclear Information System (INIS)

    Mukhono, P. M.

    2014-10-01

    The project focuses on the review of IAEA documentation on nuclear or radiological emergencies with main focus on methodology for developing and arrangement for nuclear and radiological emergencies. The main objective of this work is to identify limitations in IAEA documentation on emergency preparedness and response (EPR) and provide recommendation on the main actions needed to fill the gaps identified thus aiding in improvement of emergency preparedness and response to nuclear and radiological accidents. The review of IAEA documentation on nuclear and radiological emergency has been carried out by evaluating various emergency response elements. Several elements for EPR were highlighted covering the safety fundamentals, general safety requirements and EPR methods for development of an effective emergence response capability for nuclear or radiological emergencies. From these issues, the limitations of IAEA documentation on EPR were drawn and recommendations suggested as a means of improving EPR methods. Among them was the need for IAEA consider establishment of follow up and inspection programmes to facilitate implementation of EPR requirements in most developing countries, establishment of programmes that provide platforms for the countries to be motivated to update their system in line with the current status of emergency preparedness, review of the international information exchange aspects of nuclear emergencies in order to improve capabilities to communicate reliable data, information and decisions quickly and effectively among national authorities and their emergency and emergency response centres. (au)

  1. Decision Strategy: Radiological Evaluations: Air

    International Nuclear Information System (INIS)

    Sohier, A.

    2000-01-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on

  2. Introductory lecture series for first-year radiology residents: implementation, investment and assessment.

    Science.gov (United States)

    Chapman, Teresa; Chew, Felix S

    2013-03-01

    A lecture series aimed at providing new radiology residents a rapid course on the fundamental concepts of professionalism, safety, and interpretation of diagnostic imaging was established. Evaluation of the course's educational value was attempted through surveys. Twenty-six live 45-minute lectures presented by 16 or 17 faculty members were organized exclusively for the first class of radiology residents, held over a 2-month period at the beginning of certain weekdays. Online surveys were conducted after the course to gather feedback from residents. Average resident rotation evaluation scores were measured over the first semester for the two classes before and after this new course implementation. The lecture series was successfully organized and implemented. A total of 33 residents sat through the course over three summers. Faculty reported a reasonable number of preparation hours, and 100% of residents indicated they valued the course. Comparison of class average evaluation scores before and after the existence of this 2-month course did not significantly change. This collection of introductory lectures on professionalism, safety, and diagnostic imaging, delivered early in the first year of the radiology residency, requires a reasonable number of invested preparation hours by the faculty but results in a universal increase in resident confidence. However, we were unable to demonstrate an objective improvement in resident performance on clinical rotations. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  3. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    International Nuclear Information System (INIS)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip

    2015-01-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological data can be incorporated by means of data fusion of the two sensors' output data. (authors)

  4. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip [University of Florida, Gainesville, FL 32611 (United States)

    2015-07-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological data can be incorporated by means of data fusion of the two sensors' output data. (authors)

  5. Assessment of the radiological impact of contaminated discharges

    Energy Technology Data Exchange (ETDEWEB)

    Sweeck, L; Zeevaert, T

    1996-09-18

    A biosphere model has been used to calculate the release of radionuclides from contaminated soils and their dose impact on critical individuals in the environment. Normal evolution and accidental scenarios are considered. The objective of the model is to provide an indication of the radiological risk rather than to predict its future impact.

  6. 42 CFR 457.710 - State plan requirements: Strategic objectives and performance goals.

    Science.gov (United States)

    2010-10-01

    .... The State's strategic objectives, performance goals and performance measures must include a common... 42 Public Health 4 2010-10-01 2010-10-01 false State plan requirements: Strategic objectives and...) ALLOTMENTS AND GRANTS TO STATES Strategic Planning, Reporting, and Evaluation § 457.710 State plan...

  7. Annual report 1999 of the German Commission on Radiological Protection (SSK), and a survey of the history of the SSK in the past 25 years. With explanations on the objectives, functions, and history of the SKK, complete lists of recommendations, statements, and publications

    International Nuclear Information System (INIS)

    Gumprecht, D.; Heller, H.

    2000-01-01

    The report begins with an introduction explaining the objectives, functions and composition of the SSK. The main areas and aspects of work in 1999 are addressed and the reports, recommendations or statements prepared by the six committees of the SSK are presented. The areas of work of the committees are: radiation protection and health physics, radioecology, radiological protection in health care, radiological engineering, emergency preparedness, and non-ionizing radiation. (orig./CB) [de

  8. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  9. How job demands, resources, and burnout predict objective performance: a constructive replication.

    Science.gov (United States)

    Bakker, Arnold B; Van Emmerik, Hetty; Van Riet, Pim

    2008-07-01

    The present study uses the Job Demands-Resources model (Bakker & Demerouti, 2007) to examine how job characteristics and burnout (exhaustion and cynicism) contribute to explaining variance in objective team performance. A central assumption in the model is that working characteristics evoke two psychologically different processes. In the first process, job demands lead to constant psychological overtaxing and in the long run to exhaustion. In the second process, a lack of job resources precludes actual goal accomplishment, leading to cynicism. In the present study these two processes were used to predict objective team performance. A total of 176 employees from a temporary employment agency completed questionnaires on job characteristics and burnout. These self-reports were linked to information from the company's management information system about teams' (N=71) objective sales performance (actual sales divided by the stated objectives) during the 3 months after the questionnaire data collection period. The results of structural equation modeling analyses did not support the hypothesis that exhaustion mediates the relationship between job demands and performance, but confirmed that cynicism mediates the relationship between job resources and performance suggesting that work conditions influence performance particularly through the attitudinal component of burnout.

  10. Principles of radiological protection: new paradigms

    International Nuclear Information System (INIS)

    Ximenes, Edmir; Guimaraes, Maria Ines Calil Cury

    2009-01-01

    Full text: The relationships of workers, patients and physicians to the basic principles of radiological protection were given in this work an historical introduction that emphasizes their development from their beginnings to the current period. The evolution of scientific knowledge as regards the benefits and injuries resulting from the use of the ionizing radiation in human activities is the main focus of the work. These principles (justification, optimization and limitation) are presented in order to offer a broader view of their application fields. The principle of the optimization receives the contribution of techniques aimed to help the decision used in radiological protection. The principle of the limitation of doses is helped by the concept of limit specifically linked to a given segment of the population or a given human activity. Regarding the current relationship between physicians and patients a change of philosophy is discussed in what concerns the radiation dose supplied that should be the minimum one in relation to the diagnosis or cure objectives. The administration of radiation must follow the recommendations of ICRP - International Commission on Radiological Protection. The radiation can bring benefits if used with rationality, efficacy and care. The radiation should not be feared, but respected. (author)

  11. Socioeconomic trends in radiology

    International Nuclear Information System (INIS)

    Barneveld Binkhuysen, F.H.

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here. (orig.)

  12. Radiological and hazardous material characterization report for the south portion of the 313 Building

    International Nuclear Information System (INIS)

    Harris, R.A.

    1995-12-01

    The objective of the characterization was to determine the extent of radiological contamination and presence of hazardous materials, to allow the preparation of an accurate cost estimate, and to plan for pre-demolition cleanup work to support building isolation. The scope of services for the project included the following tasks: Records Review and Interviews; Site Reconnaissance; Radiological Survey; and Sampling and Analysis

  13. A presentation system for just-in-time learning in radiology.

    Science.gov (United States)

    Kahn, Charles E; Santos, Amadeu; Thao, Cheng; Rock, Jayson J; Nagy, Paul G; Ehlers, Kevin C

    2007-03-01

    There is growing interest in bringing medical educational materials to the point of care. We sought to develop a system for just-in-time learning in radiology. A database of 34 learning modules was derived from previously published journal articles. Learning objectives were specified for each module, and multiple-choice test items were created. A web-based system-called TEMPO-was developed to allow radiologists to select and view the learning modules. Web services were used to exchange clinical context information between TEMPO and the simulated radiology work station. Preliminary evaluation was conducted using the System Usability Scale (SUS) questionnaire. TEMPO identified learning modules that were relevant to the age, sex, imaging modality, and body part or organ system of the patient being viewed by the radiologist on the simulated clinical work station. Users expressed a high degree of satisfaction with the system's design and user interface. TEMPO enables just-in-time learning in radiology, and can be extended to create a fully functional learning management system for point-of-care learning in radiology.

  14. Utility of Interobserver Agreement Statistics in Establishing Radiology Resident Learning Curves During Self-directed Radiologic Anatomy Training.

    Science.gov (United States)

    Tureli, Derya; Altas, Hilal; Cengic, Ismet; Ekinci, Gazanfer; Baltacioglu, Feyyaz

    2015-10-01

    The aim of the study was to ascertain the learning curves for the radiology residents when first introduced to an anatomic structure in magnetic resonance images (MRI) to which they have not been previously exposed to. The iliolumbar ligament is a good marker for testing learning curves of radiology residents because the ligament is not part of a routine lumbar MRI reporting and has high variability in detection. Four radiologists, three residents without previous training and one mentor, studied standard axial T1- and T2-weighted images of routine lumbar MRI examinations. Radiologists had to define iliolumbar ligament while blinded to each other's findings. Interobserver agreement analyses, namely Cohen and Fleiss κ statistics, were performed for groups of 20 cases to evaluate the self-learning curve of radiology residents. Mean κ values of resident-mentor pairs were 0.431, 0.608, 0.604, 0.826, and 0.963 in the analysis of successive groups (P 0.8). Therefore, a junior radiology resident can obtain enough experience in identifying a rather ambiguous anatomic structure in routine MRI after a brief instruction of a few minutes by a mentor and studying approximately 80 cases by oneself. Implementing this methodology will help radiology educators obtain more concrete ideas on the optimal time and effort required for supported self-directed visual learning processes in resident education. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  15. Open Access Journal Policies: A Systematic Analysis of Radiology Journals.

    Science.gov (United States)

    Narayan, Anand; Lobner, Katie; Fritz, Jan

    2018-02-01

    The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Radiological aspects of Arthroplasties

    International Nuclear Information System (INIS)

    Garcia, Sara Eugenia; Barragan, John Henry; Narvaez, Jorge Andres

    2008-01-01

    The development of new surgical techniques, of new prosthetic materials, and the increase in life expectancy with greater coverage of health services has ugmented the performance of hip replacements in our country. The radiologist should be familiar with the different surgical techniques and prosthetic devices, the evaluation of its components and associated complications. The most frequently performed arthroplasties are: shoulder, elbow, hip and knee replacement. This article reviews the most frequent prosthetic devices used, the radiological aspects of arthroplasties and their most common complications.

  17. ICPP radiological and toxicological sabotage analysis

    International Nuclear Information System (INIS)

    Kubiak, V.R.; Mortensen, F.G.

    1995-01-01

    In June of 1993, the Department of Energy (DOE) issued Notice 5630.3A, open-quotes Protection of Departmental Facilities Against Radiological and Toxicological Sabotage,close quotes which states that all significant radiological and toxicological hazards at Department facilities must be examined for potential sabotage. This analysis has been completed at the Idaho Chemical Processing Plant (ICPP). The ICPP radiological and toxicological hazards include spent government and commercial fuels, Special Nuclear Materials (SNM), high-level liquid wastes, high-level solid wastes, and process and decontamination chemicals. The analysis effort included identification and assessment of quantities of hazardous materials present at the facility; identification and ranking of hazardous material targets; development of worst case scenarios detailing possible sabotage actions and hazard releases; performance of vulnerability assessments using table top and computer methodologies on credible threat targets; evaluation of potential risks to the public, workers, and the environment; evaluation of sabotage risk reduction options; and selection of cost effective prevention and mitigation options

  18. Source term and radiological consequences of the Chernobyl accident

    International Nuclear Information System (INIS)

    Mourad, R.

    1987-09-01

    This report presents the results of a study of the source term and radiological consequences of the Chernobyl accident. The results two parts. The first part was performed during the first 2 months following the accident and dealt with the evaluation of the source term and an estimate of individual doses in the European countries outside the Soviet Union. The second part was performed after August 25-29, 1986 when the Soviets presented in a IAEA Conference in Vienna detailed information about the accident, including source term and radiological consequences in the Soviet Union. The second part of the study reconfirms the source term evaluated in the first part and in addition deals with the radiological consequences in the Soviet Union. Source term and individual doses are calculated from measured post-accident data, reported by the Soviet Union and European countries, microcomputer program PEAR (Public Exposure from Accident Releases). 22 refs

  19. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  20. Radiology utilizing a gas multiwire detector with resolution enhancement

    Science.gov (United States)

    Majewski, Stanislaw; Majewski, Lucasz A.

    1999-09-28

    This invention relates to a process and apparatus for obtaining filmless, radiological, digital images utilizing a gas multiwire detector. Resolution is enhanced through projection geometry. This invention further relates to imaging systems for X-ray examination of patients or objects, and is particularly suited for mammography.

  1. Radiological impact of oil/gas industry

    International Nuclear Information System (INIS)

    Botezatu, E.; Grecea, C.

    2006-01-01

    The objective of this study was to assess the radiological impact on the environment and population of the oil/gas industry that is non-nuclear industry but uses and can produce materials, with an enhanced content of naturally occurring radionuclides. The natural radioactivity levels in the oil field environmental media, which could represent a risk for the people living in the areas influenced by this non-nuclear industry, do not indicate an increase in the natural radiation background. From a radiological point of view, the situation does not pose any immediate concern. Some places however need further investigations, with special emphasis on the control of 226 Ra releases to prevent from polluting the environment with this radionuclide. The growing concern amongst the population about the quality of their environment increases the significance of impact assessment of radioactive releases into the environment even if natural radionuclides occur. (N.C.)

  2. The Radiology of Renal Trauma

    African Journals Online (AJOL)

    1974-05-15

    May 15, 1974 ... Retrograde pyelography was performed in 3 patients and renal angio- graphy in 22. Of the 210 cases referred, abnormal radio- logical signs were observed in 112. All the radiological in- vestigations were reviewed to assess the frequency of the various findings. RESULTS. The Plain Film of the Abdomen.

  3. Application of improved topsis method to comprehensive assessment of radiological environmental quality

    International Nuclear Information System (INIS)

    Shi Dongsheng; Di Yuming; Zhou Chunlin

    2007-01-01

    TOPSIS is a method for multiobjective decision-making, which can be applied to comprehensive assessment of radiological environmental quality. This paper introduces the principle of TOPSIS method and sets up the model of improved TOPSIS method, discusses the application of improved TOPSIS method to comprehensive assessment of radiological environmental quality. This method sufficiently makes use of the information of the optimal matrix. Analysis of practical examples using MATLAB program shows that it is objectively reasonable and feasible to comprehensively assess radiological environmental quality by improved TOPSIS method. This paper also provides the result of optimum number of sites and compares it with optimal index method based on TOPSIS method and traditional method. (authors)

  4. Infant manual performance during reaching and grasping for objects moving in depth

    Directory of Open Access Journals (Sweden)

    Erik eDomellöf

    2015-08-01

    Full Text Available Few studies have observed investigated manual asymmetries performance in infants when reaching and grasping for objects moving in directions other than across the fronto-parallel plane. The present preliminary study explored manual object-oriented behavioral strategies and hand side preference in 8- and 10-month-old infants during reaching and grasping for objects approaching in depth from three positions (midline, and 27° diagonally from the left, and right, midline. Effects of task constraint by using objects of three different types and two sizes were further examined for behavioral strategies and . The study also involved measurements of hand position opening prior to grasping., and Additionally, assessments of general hand preference by a dedicated handedness test were performed. Regardless of object starting position, the 8-month-old infants predominantly displayed right-handed reaches for objects approaching in depth. In contrast, the older infants showed more varied strategies and performed more ipsilateral reaches in correspondence with the side of the approaching object. Conversely, 10-month-old infants were more successful than the younger infants in grasping the objects, independent of object starting position. The findings support the possibility of a shared underlying mechanism regarding for infant hand use strategies when reaching and grasping for horizontally objects moving in depth are similar to those from earlier studies using objects moving along a horizontal pathand vertically moving objects. Still, initiation times of reaching onset were generally long in the present study, indicating that the object motion paths seemingly affected how the infants perceived the intrinsic properties and spatial locations of the objects, possibly with an effect on motor planning. Findings are further discussed in relation to future investigations of infant reaching and grasping for objects approaching in depth.

  5. Development of a Program on quality assurance in radiotherapy and radiology

    International Nuclear Information System (INIS)

    Tovar, Julio

    2000-01-01

    In this paper the development of a program of QA in radiotherapy and radiology is described. The objectives, resources, manpower and the cooperation between the IAEA and the Direccion General de Energia are outlined

  6. Adaptive support for user interface customization : a study in radiology

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; van Ooijen, Peter M. A.

    Objectives: This study aimed to evaluate the usefulness of adaptive customization support in a natural work environment: the Picture Archiving and Communication System (PACS) in radiology. Methods: Adaptive support was given in the form of customization suggestions, generated based on behavioral

  7. Unenhanced computed tomography in acute renal colic reduces cost outside radiology department

    DEFF Research Database (Denmark)

    Lauritsen, J.; Andersen, J.R.; Nordling, J.

    2008-01-01

    BACKGROUND: Unenhanced multidetector computed tomography (UMDCT) is well established as the procedure of choice for radiologic evaluation of patients with renal colic. The procedure has both clinical and financial consequences for departments of surgery and radiology. However, the financial effect...... outside the radiology department is poorly elucidated. PURPOSE: To evaluate the financial consequences outside of the radiology department, a retrospective study comparing the ward occupation of patients examined with UMDCT to that of intravenous urography (IVU) was performed. MATERIAL AND METHODS......) saved the hospital USD 265,000 every 6 months compared to the use of IVU. CONCLUSION: Use of UMDCT compared to IVU in patients with renal colic leads to cost savings outside the radiology department Udgivelsesdato: 2008/12...

  8. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  9. The current status of interventional radiology in Canada: results of a survey by the Canadian Interventional Radiology Association

    Energy Technology Data Exchange (ETDEWEB)

    Millward, S.F.; Holley, M.L. [Univ. of Western Ontario, London Health Sciences Centre, Dept. of Radiology, London, Ontario (Canada)

    2001-04-01

    To evaluate the current status of interventional radiology in Canada. A questionnaire was sent to 28 Canadian interventional radiologists (defined as a physician who performs any type of interventional procedure, including biopsies, but excluding interventional neuroradiology) practising in both tertiary and community hospitals in the major centres in all provinces except Prince Edward Island. Twenty-two (79%) of 28 surveys were completed and returned, providing data about 86 interventional radiologists (IRs). IRs were performing almost all of the following procedures at their institutions: inferior vena cava filter placement, venous angioplasty, dialysis fistula angioplasty, diagnostic and therapeutic pulmonary and bronchial artery procedures, diagnostic and therapeutic procedures of the lower extremity and renal arteries, percutaneous abscess and biliary drainage procedures, percutaneous nephrostomy, and fibroid embolization. A second group of procedures, performed by both IRs and non-radiologists in most institutions, included: all types of central venous catheter placements, pleural drainage, and gastrostomy tube placement. Procedures not being performed by anyone in a number of institutions included: dialysis graft thrombolysis, varicocele embolization, transjugular intrahepatic portosystemic shunts, palliative stenting of the gastrointestinal tract, fallopian tube recannalization, and liver and prostate tumour treatments. The factors most often limiting the respondents' ability to provide a comprehensive interventional service were the interventional radiology inventory budget and the availability of interventional radiology rooms; 50% of respondents indicated the number of available nurses, technologists and IRs was also an important limiting factor. IRs in Canada still play a major role in many of the most commonly performed procedures. However, limited availability of resources and personnel in many institutions may be hampering the ability of IRs to

  10. A practical approach for inexpensive searches of radiology report databases.

    Science.gov (United States)

    Desjardins, Benoit; Hamilton, R Curtis

    2007-06-01

    We present a method to perform full text searches of radiology reports for the large number of departments that do not have this ability as part of their radiology or hospital information system. A tool written in Microsoft Access (front-end) has been designed to search a server (back-end) containing the indexed backup weekly copy of the full relational database extracted from a radiology information system (RIS). This front end-/back-end approach has been implemented in a large academic radiology department, and is used for teaching, research and administrative purposes. The weekly second backup of the 80 GB, 4 million record RIS database takes 2 hours. Further indexing of the exported radiology reports takes 6 hours. Individual searches of the indexed database typically take less than 1 minute on the indexed database and 30-60 minutes on the nonindexed database. Guidelines to properly address privacy and institutional review board issues are closely followed by all users. This method has potential to improve teaching, research, and administrative programs within radiology departments that cannot afford more expensive technology.

  11. [eLearning-radiology.com--sustainability for quality assurance].

    Science.gov (United States)

    Ketelsen, D; Talanow, R; Uder, M; Grunewald, M

    2009-04-01

    The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. At the time of assessment, 56.4 % (102 / 181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. More than 50 % of investigated radiological e-learning tools on the Internet were not accessible after a period of 5 to 8 years. As a consequence, an independent, international tool for quality assurance was designed and published online under www.eLearning-radiology.com .

  12. Nanoscopic designs of radiological protection in environmental scale for the Fukushima nuclear accident: Strategy by dispersion, dissolution, and filtration

    International Nuclear Information System (INIS)

    Woo, Tae Ho

    2016-01-01

    Highlights: • New kind of radiological protection concept is introduced. • The shielding concept is accompanied with the water spray system. • The solubility of radioactive material could be used for protection. • Practical method is suggested. • The system is variable by the random number quantities. - Abstract: The environmental defense system in the nuclear power plants (NPPs) is investigated in the aspect of the environmental scale incorporated with atmospheric and marine sectors. The object is to find the radiological protection protocol in the environmental scale which is different from the conventional three kinds of radiological protection principles. Conventional laboratory based principles are not applicable in the mass failure accident such as the case of Fukushima disaster. This newly introduced protocol has many useful applications for the nature treatment oriented methods where the atmospheric protection of dispersion and dissolution is performed first and the filtration of seawater would follow. The maximum and minimum values in fan velocity are about 7.5 m/s and 5.3 m/s respectively. For the spray system, the mole fractions by the water spray are shown where maximum and minimum values are 6.57 × 10 −17 and 8.84 × 10 −19 moles respectively. The maximum and minimum values of discharged values in filtration are 99.4 and 1.3 square velocity (m/s), respectively. The total and general radiological protection concept is suggested in the nanoscopic molecular scale performance.

  13. Radiology residents' experience with intussusception reduction

    International Nuclear Information System (INIS)

    Bateni, Cyrus; Stein-Wexler, Rebecca; Wootton-Gorges, Sandra L.; Li, Chin-Shang

    2011-01-01

    Residents should be exposed to adequate procedural volume to act independently upon completion of training. Informal inquiry led us to question whether residents encounter enough intussusception reductions to become comfortable with the procedure. We sought to determine radiology residents' exposure to intussusception reductions, and whether their experiences vary by region or institution. U.S. radiology residency program directors were asked to encourage their residents to complete a 12-question online survey describing characteristics of their pediatric radiology department, experiences with intussusception reduction, and confidence in their own ability to perform the procedure. Six hundred sixty-four residents responded during the study period. Of those, 308 (46.4%) had not experienced an intussusception reduction, and 228 (34%) had experienced only one or two. Twenty-two percent of fourth-year residents had never experienced an intussusception reduction, and 21% had experienced only one. Among second- through fourth-year residents, only 99 (18.3%) felt confident that they could competently reduce an intussusception (P < 0.0001), and 336 (62.2%) thought they would benefit from a computer-assisted training model simulating intussusception reduction (P < 0.0001). Radiology residents have limited opportunity to learn intussusception reduction and therefore lack confidence. Most think they would benefit from additional training with a computer-simulation model. (orig.)

  14. Quality assurance program in diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, Alejandro; Borges, J.C.

    1994-01-01

    Aiming to elaborate a methodology to optimize the performance of the Radiology Service of the Military Police Hospital, in Rio dee Janeiro, some goals were established: improvement of the attendance to patients; improvement of the qualification of technicians; achievement and maintenance of high degrees of quality in each step of the radiological process; improvement of the image quality; optimization of dose per examination and cost reduction. The procedure used to detect faults in the radiological process was the analysis of causes of film losses. Results show a 70% reduction in the film rejection rate. 74% of total identified faults were due to equipment, 11% to films, 10% to patients and 5% to developing. The reduction in the cost of developed film reached 75%. A training course given to the staff of the radiological service fully reached its goals, contributing, with the staff motivation, mostly to the success of the program. This success indicates that, with a serious persistent work, it is possible to offer to patients services within their expectations, even at a public hospital. Such programs should be supported by health authorities, not only due to their technical and economic needs but, mostly, due to their social implications. (author). 10 refs., 11 figs

  15. Primary cerebral lymphoma: radiological findings

    International Nuclear Information System (INIS)

    Ruiz, J.C.; Grandse, D.; Equidazu, J.; Elizagaray, E.; Grande, J.; Carrandi, J.

    1990-01-01

    We present four cases of primary cerebral lymphoma in non-immunodepressed adult patients. All cases were dsemonstrated with pathological study. CAT study showed solitary or multiple isodense lesions, which incorporated avidly and homoneneously the contrast. Arteriography performed in three patients and magnetic resonance, performed in one did not help for diagnosis. We also review the radiological findings obtained with different imaging methods, and suggest the criteria which could be useful for early diagnosis (Author)

  16. Radiological Effluent Technical Specifications (RETS) implementation, Kewaunee Nuclear Power Plant

    International Nuclear Information System (INIS)

    Serrano, W.; Akers, D.W.

    1985-06-01

    A review of the Radiological Effluent Technical Specifications (RETS) for the Kewaunee Nuclear Power Plant was performed. The principal review guidelines used were NUREG-0133, ''Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants,'' and Draft 7'' of NUREG-0472, Revision 3, ''Radiological Effluent Technical Specifications for Pressurized Water Reactors.'' Draft submittals were discussed with the Licensee by the NRC staff until all items requiring changes to the Technical Specifications were resolved. The Licensee then submitted final proposed RETS to the NRC which were evaluated and found to be in compliance with the NRC review guidelines. The proposed Offsite Dose Calculation Manual and the Radiological Environmental Monitoring Manual were reviewed and generally found to be in compliance with the NRC review guidelines

  17. Congenital hip dislocation: Radiological screening or diagnosis?

    International Nuclear Information System (INIS)

    Kalifa, G.; Faure, C.

    1987-01-01

    Congenital hip dislocation is a perfect example of public health problems: its incidence is high 0.6, to 2% of newborns in France and an early detection allows an easy and successful treatment. The current situation in our country is not satisfactory for several reasons: - Too many children are treated without reasons because of misleading radiological pictures; - Conversely, some dislocations are discovered only at the walking age, the treatment becoming then more difficult and less effective; - Almost 300,000 radiological examinations of the hip for screening are performed each year and among them 100,000 in newborns. This is not satisfactory as it is commonly admitted now that radiological examination at birth is unreliable and frequently misleading. For all these reasons a special working group has been settled up by the General Direction of Health, including physicians of different practices, from different specialities. The conclusion of this group will be published in a special booklet and can be summarized as follows: The group recommends to perform detection of congenital hip dislocation mainly by the clinical examination. This examination may be difficult but it must be performed very early, the first day of life, repeated several times, at the end of the first week and during the first, second, and third month. Every baby in this country must undergo several clinical examinations up to one year of age

  18. Clinical, radiological, surgical, and pathological determinants of olfactory groove schwannoma

    Directory of Open Access Journals (Sweden)

    Andi Sadayandi Ramesh

    2014-01-01

    Full Text Available Background: Olfactory groove schwannomas (OGS are rare anterior cranial fossa base tumors with only 41 cases reported in literature. Olfactory ensheathing cell schwannoma (OECS has similar clinico-radiological features as OGS, but a different cell of origin. In recent years, there is growing interest in OECS as more cases are being reported. Aims: The objective was to study the clinico-radiological features of OGS and define the histological differentiation from OECS. Materials and Methods: We retrospectively analyzed clinical, radiological, surgical and histopathological picture of all cases of OGS managed in our institute. Immuno histochemical studies were performed in these tumors for differentiating from OECS. A comprehensive review of articles published until date describing the operative treatment was done. Results: All three cases had presented with seizures, two had anosmia and papilledema. Gross-total resection was achieved in all our patients. One patient expired in the postoperative period due to septicemia. Positive expression to newer immuno histochemical biomarker CD57 (Leu7, with negative staining to smooth muscle α-actin (SMA was helpful in confirming the diagnosis of OGS and differentiating it from OECS in all our cases. Conclusions: OECS, though rare has to be differentiated from OGS using immuno histochemistry. Gross-total resection of OGS with preservation of olfactory function is often possible and curative. Although these tumors are commonly treated with microsurgical skull base approaches, an endoscopic endonasal approach can be considered in some cases, with repair using mucoperiosteal pedicled flap to prevent cerebrospinal fluid leak.

  19. Cost analysis in interventional radiology-A tool to optimize management costs

    International Nuclear Information System (INIS)

    Clevert, D.-A.; Stickel, M.; Jung, E.M.; Reiser, M.; Rupp, N.

    2007-01-01

    Objective: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. Materials and methods: All products used in Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. Results: Total annual material turnover was 353,000 Euro . The value of all A-products determined by the inventory was 260,000 Euro . Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year Euro . The resulting total saving was 17,200 Euro . Improved stores management added another 37,500 Euro. The total cost cut of 52,000 Euro is equivalent to 14.7% of annual expenses. Conclusion: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients

  20. ATLAS Physics Objects Status and Performance at 13 TeV

    CERN Document Server

    Riu, Imma; The ATLAS collaboration

    2015-01-01

    Important for physics analyses is the understanding and commissioning of physics objects. A first look at the 13 TeV data has proved a reasonably good Monte Carlo modelling of the objects and they have been used for first physics measurements and searches beyond the Standard Model. This talk is to be given at the Top Workshop and provides an overview of the status and performance of the physics objects with the early 13 TeV data taken in summer 2015.

  1. White Paper: Curriculum in Interventional Radiology.

    Science.gov (United States)

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Decision Strategy: Radiological Evaluations: Air

    Energy Technology Data Exchange (ETDEWEB)

    Sohier, A

    2000-07-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on.

  3. The Importance of Human-Computer Interaction in Radiology E-learning.

    Science.gov (United States)

    den Harder, Annemarie M; Frijlingh, Marissa; Ravesloot, Cécile J; Oosterbaan, Anne E; van der Gijp, Anouk

    2016-04-01

    With the development of cross-sectional imaging techniques and transformation to digital reading of radiological imaging, e-learning might be a promising tool in undergraduate radiology education. In this systematic review of the literature, we evaluate the emergence of image interaction possibilities in radiology e-learning programs and evidence for effects of radiology e-learning on learning outcomes and perspectives of medical students and teachers. A systematic search in PubMed, EMBASE, Cochrane, ERIC, and PsycInfo was performed. Articles were screened by two authors and included when they concerned the evaluation of radiological e-learning tools for undergraduate medical students. Nineteen articles were included. Seven studies evaluated e-learning programs with image interaction possibilities. Students perceived e-learning with image interaction possibilities to be a useful addition to learning with hard copy images and to be effective for learning 3D anatomy. Both e-learning programs with and without image interaction possibilities were found to improve radiological knowledge and skills. In general, students found e-learning programs easy to use, rated image quality high, and found the difficulty level of the courses appropriate. Furthermore, they felt that their knowledge and understanding of radiology improved by using e-learning. In conclusion, the addition of radiology e-learning in undergraduate medical education can improve radiological knowledge and image interpretation skills. Differences between the effect of e-learning with and without image interpretation possibilities on learning outcomes are unknown and should be subject to future research.

  4. Public competitive examination for radiology technologist: knowledge in radiation protection required in Brazil

    International Nuclear Information System (INIS)

    Oliveira, J.S.; Silva, K.R.; Gomes, A.S.

    2017-01-01

    Ionizing radiations are used in areas such as health, industry and safety, not only in the private sector, but also in the public. Thus, it is necessary the radiological protection, a set of studies and practices that increases the safety in these applications, where the professional involved is the technologist in radiology. The objective was to analyze the contents effectively required by the Brazilian public agencies in their competitions for radiology technologist, regarding the area of radiological protection, identifying their profile of requirement. It consisted of three stages: first, a survey of all the public competitions already carried out in the country up to the end of 2016, that requested a diploma of graduation in Technology in Radiology; second, all the specific questions were collected and grouped in an electronic text file; third, issues involving radiological protection were segregated, using as reference the 2017 edition of the National Nuclear Energy Commission's General Proof of Radioprotection Supervision. The results showed that almost 40% of the competition questions were about radiation protection. From this sampling, the topics most covered were: radiological safety (36%), fundamentals of atomic and nuclear physics (24%) and biological effects of radiation (16%). It is concluded that the competitions for radiologist technologist have the profile of concentration of exigency in radiological safety, fundamentals of atomic and nuclear physics and biological effects of the radiations

  5. The prevalence of radiological markers of renal osteodystrophy in ...

    African Journals Online (AJOL)

    Objectives: To study the prevalence of renal osteodystrophy in Chronic renal failure patients in Enugu, using radiological methods. Subjects and Methods: Ninety adult patients (56 male and 34 female) were recruited from the renal clinics of the University of Nigeria Teaching Hospital, Enugu over a period of twelve ...

  6. Effective doses in paediatric radiology

    International Nuclear Information System (INIS)

    Iacob, Olga; Diaconescu, Cornelia; Roca, Antoaneta

    2001-01-01

    Because of their longer life expectancy, the risk of late manifestations of detrimental radiation effects is greater in children than in adults and, consequently, paediatric radiology gives ground for more concern regarding radiation protection than radiology of adults. The purpose of our study is to assess in terms of effective doses the magnitude of paediatric patient exposure during conventional X-ray examinations, selected for their high frequency or their relatively high doses to the patient. Effective doses have been derived from measurements of dose-area product (DAP) carried out on over 900 patients undergoing X-ray examinations, in five paediatric units. The conversion coefficients for estimating effective doses are those calculated by the NRPB using Monte-Carlo technique on a series of 5 mathematical phantoms representing 0, 1, 5, 10 and 15 year old children. The annual frequency of X-ray examinations necessary for collective dose calculation are those reported in our last national study on medical exposure, conducted in 1995. The annual effective doses from all medical examinations for the average paediatric patient are as follows: 1.05 mSv for 0 year old, 0.98 mSv for 1 year old, 0.53 mSv for 5 year old, 0.65 mSv for 10 year old and 0.70 mSv for 15 year old. The resulting annual collective effective dose was evaluated at 625 man Sv with the largest contribution of pelvis and hip examinations (34%). The annual collective effective associated with paediatric radiology in Romania represent 5% of the annual value resulting from all diagnostic radiology. Examination of the chest is by far the most frequent procedure for children, accounting for about 60 per cent of all annually performed X-ray conventional examinations. Knowledge of real level of patient dose is an essential component of quality assurance programs in paediatric radiology. (authors)

  7. Effects of Selected Object Characteristics on Object Permanence Test Performance.

    Science.gov (United States)

    Lingle, Kathleen M.; Lingle, John H.

    A study was conducted to investigate the degree to which both object familiarity and motivational factors influence infants' search behavior in an object permanence test. Infants' search behavior for an unfamiliar test object was compared with search behavior for (a) an experientially familiar object that each infant had played with daily for a…

  8. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  9. Radiology trainer. Musculoskeletal system

    International Nuclear Information System (INIS)

    Staebler, A.; Erlt-Wagner, B.

    2006-01-01

    This book enables students to simulate examinations. The Radiology Trainer series comprises the whole knowledge of radiology in the form of case studies for self-testing. It is based on the best-sorted German-language collection of radiological examinations of all organ regions. Step by step, radiological knowledge is trained in order to make diagnoses more efficient. The book series ensures optimal preparation for the final medical examinations and is also a valuable tool for practical training. (orig.)

  10. The Radiological Research Accelerator Facility:

    International Nuclear Information System (INIS)

    Hall, E.J.; Goldhagen, P.

    1988-07-01

    The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generated a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Radiological Research Laboratory (RRL) of Columbia University, and its operation is supported as a National Facility by the U.S. Department of Energy. As such, RARAF is available to all potential users on an equal basis, and scientists outside the RRL are encouraged to submit proposals for experiments at RARAF. Facilities and services are provided to users, but the research projects themselves must be supported separately. RARAF was located at BNL from 1967 until 1980, when it was dismantled and moved to the Nevis Laboratories of Columbia University, where it was then reassembled and put back into operation. Data obtained from experiment using RARAF have been of pragmatic value to radiation protection and to neutron therapy. At a more fundamental level, the research at RARAF has provided insight into the biological action of radiation and especially its relation to energy distribution in the cell. High-LET radiations are an agent of special importance because they can cause measurable cellular effects by single particles, eliminating some of the complexities of multievent action and more clearly disclosing basic features. This applies particularly to radiation carcinogenesis. Facilities are available at RARAF for exposing objects to different radiations having a wide range of linear energy transfers (LETs)

  11. Anismus, Physiology, Radiology: Is It Time for Some Pragmatism? A Comparative Study of Radiological and Anorectal Physiology Findings in Patients With Anismus.

    Science.gov (United States)

    Pisano, Umberto; Irvine, Lesley; Szczachor, Justina; Jawad, Ahsin; MacLeod, Andrew; Lim, Michael

    2016-10-01

    Anismus is a functional disorder featuring obstructive symptoms and paradoxical contractions of the pelvic floor. This study aims to establish diagnosis agreement between physiology and radiology, associate anismus with morphological outlet obstruction, and explore the role of sphincteric pressure and rectal volumes in the radiological diagnosis of anismus. Consecutive patients were evaluated by using magnetic resonance imaging proctography/fluoroscopic defecography and anorectal physiology. Morphological radiological features were associated with physiology tests. A categorical analysis was performed using the chi-square test, and agreement was assessed via the kappa coefficient. A Mann-Whitney test was used to assess rectal volumes and sphincterial pressure distributions between groups of patients. A P-value of Anismus was seen radiologically and physiologically in 18 (41.8%) and 12 patients (27.9%), respectively. The agreement between modalities was 0.298 (P = 0.04). Using physiology as a reference, radiology had positive and negative predictive values of 44% and 84%, respectively. Rectoceles, cystoceles, enteroceles and pathological pelvic floor descent were not physiologically predictive of animus (P > 0.05). The sphincterial straining pressure was 71 mmHg in the anismus group versus 12 mmHg. Radiology was likely to identify anismus when the straining pressure exceeded 50% of the resting pressure (P = 0.08). Radiological techniques detect pelvic morphological abnormalities, but lead to overdiagnoses of anismus. No proctographic pathological feature predicts anismus reliably. A stronger pelvic floor paradoxical contraction is associated with a greater likelihood of detection by proctography.

  12. Diagnostic Accuracy of Focused Assessment with Sonography for Blunt Abdominal Trauma in Pediatric Patients Performed by Emergency Medicine Residents versus Radiology Residents

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2018-05-01

    Full Text Available Introduction: Focused assessment with sonography for trauma (FAST has been shown to be useful to detect intraperitoneal free fluid in patients with blunt abdominal trauma (BAT. Objective: We compared the diagnostic accuracy of FAST performed by emergency medicine residents (EMRs and radiology residents (RRs in pediatric patients with BAT. Method: In this prospective study, pediatric patients with BAT and high energy trauma who were referred to the emergency department (ED at Al-Zahra and Kashani hospitals in Isfahan, Iran, were evaluated using FAST, first by EMRs and subsequently by RRs. The reports provided by the two resident groups were compared with the final outcome based on the results of the abdominal computed tomography (CT, operative exploration, and clinical observation. Results: A total of 101 patients with a median age of 6.75 ± 3.2 years were enrolled in the study between January 2013 and May 2014. These patients were evaluated using FAST, first by EMRs and subsequently by RRs. A good diagnostic agreement was noted between the results of the FAST scans performed by EMRs and RRs (κ = 0.865, P < 0.001. The sensitivity, specificity, positive and negative predictive values, and accuracy in evaluating the intraperitoneal free fluid were 72.2%, 85.5%, 52%, 93.3%, and 83.2%, respectively, when FAST was performed by EMRs and 72.2%, 86.7%, 54.2%, 93.5%, and 84.2%, respectively, when FAST was performed by RRs. No significant differences were seen between the EMR- and RR-performed FAST. Conclusion: In this study, FAST performed by EMRs had acceptable diagnostic value, similar to that performed by RRs, in patients with BAT.

  13. Radiological changes of the hands of systemic sclerosis

    International Nuclear Information System (INIS)

    Brun, B.; Serup, J.; Hagdrup, H.

    1983-01-01

    Radiological examination of the hands was performed in 41 patients with systemic sclerosis. Pathological changes were found in 39 patients. Eighteen patients had subcutaneous calcifications and 11 had atrophy of the finger pulps. Bone resorption of ungual tufts was found in 11 patients. Juxta-articular osteoporosis was seen in 9 patients and periarticular bone erosions in 8 patients indicating erosive arthropathy. Osteoarthritis and generalized osteoporosis were seen in 10 and 7 patients, respectively. Radiological examination of the hands is recommended during treatment. (Authors)

  14. On the radiology of thorium-uranium electro breeding

    International Nuclear Information System (INIS)

    Gai, E.V.; Rabotnov, N.S.; Shubin, Y.N.

    1995-01-01

    Radiological problems arising in thorium-uranium electro-breeding with thorium accelerator target are discussed. Following radiological problems are discussed and evaluated in simplified model calculations: U-232 formation, accumulation of light Th isotopes in (n, xn) reactions on thorium target: accumulation of the same nuclides in final repository after alpha-decay of uranium isotopes. The qualitative comparison of U-Pu and U-Th fuel cycles is performed. The problems seem to be serious enough to justify detailed quantitative investigation. (authors)

  15. Computerized system to perform a general radiological evaluation of the persons that live in areas affected by the nuclear accident of Chernobyl

    International Nuclear Information System (INIS)

    Cruz Suarez, R.; Valdes, M.

    1993-01-01

    A computer program (EVACID) was developed with the purpose of performing a general radiological evaluation. EVACID system allows to automate an important group of dosimetric calculations, as well as to store, codify analyze and relate among them the medical information of the persons affected by the nuclear accident of Chernobyl

  16. Issues with performance measures for dynamic multi-objective optimisation

    CSIR Research Space (South Africa)

    Helbig, M

    2013-06-01

    Full Text Available Symposium on Computational Intelligence in Dynamic and Uncertain Environments (CIDUE), Mexico, 20-23 June 2013 Issues with Performance Measures for Dynamic Multi-objective Optimisation Mard´e Helbig CSIR: Meraka Institute Brummeria, South Africa...

  17. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  18. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    Science.gov (United States)

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  19. RADIOPROTECTION CAMPAIGN AND CARD: EDUCATIONAL STRATEGIES THAT REDUCE CHILDREN'S EXCESSIVE EXPOSURE TO RADIOLOGICAL EXAMS.

    Science.gov (United States)

    Bernardo, Mônica Oliveira; Almeida, Fernando Antonio de; Morgado, Flavio

    2017-01-01

    To analyze the results of an initiative aimed at improving the reasonable use of radiological examinations, ensuring their technical quality, implementing a radioprotection campaign that includes training of the professional team, and introducing the radioprotection card for children under 12 years old as a tool for parents and doctors to control children's exposure to radiation. The study was held in a health care insurance system covering 140,000 people. A radioprotection campaign was implemented according to Image Gently • protocols, ensuring the lowest dose of radiation and the quality of examinations, and the radioprotection card was implemented. To assess the effectiveness of these actions, the number of radiological examinations performed at the pediatric emergency room in a period of one year preceding the campaign was compared with the number of radiological examinations performed one year after the campaign. The campaign was well accepted by all professionals, families, and patients involved. In the year following the implementation of radioprotection strategies, there was a 22% reduction of radiological examinations performed at the pediatric emergency room. There was also a 29% reduction in the request of two or more radiological examinations for the same child or examinations with two or more incidences. The campaign and the radioprotection card for children under 12 years old proved to be feasible strategies and correlated with a reduction in radiological examinations requested and performed at the pediatric emergency room.

  20. Radiological services pact relies on teamwork and experience [dose management

    International Nuclear Information System (INIS)

    Cruden, D.S.

    1988-01-01

    Virginia Power has entered into a radiological service agreement with Westinghouse. The contract commits Westinghouse to work in partnership with Virginia Power to improve performance in the areas of radiological protection, decontamination, ALARA, and radioactive waste management. It is expected that the agreement will solve the problems caused by the shortage of qualified contractor personnel during scheduled outages. (U.K.)