  1. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  2. Evaluation of medical radiation exposure in pediatric interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Valeria Coelho Costa; Navarro, Marcus Vinicius Teixeira; Oliveira, Aline da Silva Pacheco, E-mail: vccnavarro@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil); Maia, Ana Figueiredo [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Oliveira, Adriano Dias Dourado [Sociedade Brasileira de Hemodinamica e Cardiologia Intervencionista, Salvador, BA (Brazil)

    2012-07-15

    Objective: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. Materials and Methods: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. Results: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm{sup 2} and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm{sup 2} and 961.0 mGy. Conclusion: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates. (author)

  3. A pilot study of radiation exposures arising from interventional radiology procedures

    International Nuclear Information System (INIS)

    Pellet, S.; Giczi, F.; Gaspardy, G.; Temesi, A.; Ballay, L.

    2006-01-01

    Full text of publication follows: In the past 25 years, considerable number of new therapeutic procedures have been worked out and adopted in radiology. These interventional procedures are mainly based on angiographic methods. During these procedures the exposure of patients and staff are usually greater than of conventional radiography and fluoroscopy as a consequence of longer fluoroscopy times and great number of cine-radiography. In the latest years radiation-induced skin injuries occurred in some patients. Injuries to physicians and staff performing interventional procedures have also been observed. In our days interventional procedures are widely used and more sophisticated procedures are worked out and adopted. Consequently, there is a need for the protection of the patient and the staff on a higher level. Radiation protection of intervention radiology deserves a distinguish attention. In Hungary interventional radiology were performed in 36 laboratories in 2003. According to statistical data the gross number of interventional radiological procedures were 19442. The most frequently performed procedures were the P.T.C.A., the coronary and ilio-femoral stent implantation and chemo-embolization. In 2004, the National Research Institute for Radiobiology and Radio-hygiene and the National Patient Dose Evaluation Program started a pilot study of radiation exposures arising from interventional radiology procedures. During the study the patient exposure were measured by D.A.P.-meters. The patient skin dose and the staff dose were performed by thermoluminescent chips. In their presentation the authors present the most important results of the study. (authors)

  4. ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures.

    Science.gov (United States)

    López, P Ortiz; Dauer, L T; Loose, R; Martin, C J; Miller, D L; Vañó, E; Doruff, M; Padovani, R; Massera, G; Yoder, C

    2018-03-01

    In recent publications, such as Publications 117 and 120, the Commission provided practical advice for physicians and other healthcare personnel on measures to protect their patients and themselves during interventional procedures. These measures can only be effective if they are encompassed by a framework of radiological protection elements, and by the availability of professionals with responsibilities in radiological protection. This framework includes a radiological protection programme with a strategy for exposure monitoring, protective garments, education and training, and quality assurance of the programme implementation. Professionals with responsibilities in occupational radiological protection for interventional procedures include: medical physicists; radiological protection specialists; personnel working in dosimetry services; clinical applications support personnel from the suppliers and maintenance companies; staff engaged in training, standardisation of equipment, and procedures; staff responsible for occupational health; hospital administrators responsible for providing financial support; and professional bodies and regulators. This publication addresses these elements and these audiences, and provides advice on specific issues, such as assessment of effective dose from dosimeter readings when an apron is worn, estimation of exposure of the lens of the eye (with and without protective eyewear), extremity monitoring, selection and testing of protective garments, and auditing the interventional procedures when occupational doses are unusually high or low (the latter meaning that the dosimeter may not have been worn).

  5. Central venous catheterization: comparison between interventional radiological procedure and blind surgical reocedure

    International Nuclear Information System (INIS)

    Song, Won Gyu; Jin, Gong Yong; Han, Young Min; Yu, He Chul

    2002-01-01

    To determine the usefulness and safety of radiological placement of a central venous catheter by prospectively comparing the results of interventional radiology and blind surgery. For placement of a central venous catheter, the blind surgical method was used in 78 cases (77 patients), and the interventional radiological method in 56 cases (54 patients). The male to female ratio was 66:68, and the patients' mean age was 48 (range, 18-80) years. A tunneled central venous catheter was used in 74 cases, and a chemoport in 60. We evaluated the success and duration of the procedures, the number of punctures required, and ensuing complications, comparing the results of the two methods. The success rates of the interventional radiological and the blind surgical procedure were 100% and 94.8%, respectively. The duration of central catheterization was 3-395 (mean, 120) day, that of chemoport was 160.9 days, and that of tunneled central venous catheter was 95.1 days. The mean number of punctures of the subclavian vein was 1.2 of interventional radiology, and 2.1 for blind surgery. The mean duration of the interventional radiology and the blind surgical procedure was, respectively, 30 and 40 minutes. The postprocedure complication rate was 27.6% (37 cases). Early complications occurred in nine cases (6.7%): where interventional radiology was used, there was one case of hematoma, and blind surgery gave rise to hematoma (n=2), pneumothorax (n=2), and early deviation of the catheter (n=4). Late complications occurred in 32 cases (23.9%). Interventional radiology involved infection (n=4), venous thrombosis (n=1), catheter displacement (n=2) and catheter obstruction (n=5), while the blind surgical procedure gave rise to infection (n=5), venous thrombosis (n=3), catheter displacement (n=4) and catheter obstruction (n=8). The success rate of interventional radiological placement of a central venous catheter was high and the complication rate was low. In comparison with the blind

  6. An observation study of radiation exposure to nurses during interventional radiology procedure

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Aoki, Atsuko

    2010-01-01

    The purpose of this study was to prospectively measure the level of radiation exposure among nursing staff during interventional radiology procedures. All interventional radiology procedures performed at our institution between April 20 and June 19, 2009 were included in this study. Radiation exposure was measured as the equivalent dose penetrating tissue to a depth of 10 mm using electronic personal dosimeters attached outside (Ha) and inside (Hb) lead aprons. Effective dose (HE) was estimated by calculating from Ha and Hb. In total, data from 68 procedures were included in this study. Four nurses performed 71 nursing cares. The mean Ha was 0.70±1.0 μSv, while the mean Hb was 0.06±0.2 μSv. The mean HE was 0.14±0.3 μSv. The present findings indicate that during interventional radiology procedures, nurses were exposed to very low levels of radiation. (author)

  7. Occupational exposures from selected interventional radiological procedures

    International Nuclear Information System (INIS)

    Janeczek, J.; Beal, A.; James, D.

    2001-01-01

    The number of radiology and cardiology interventional procedures has significantly increased in recent years due to better diagnostic equipment resulting in an increase in radiation dose to the staff and patients. The assessment of staff doses was performed for cardiac catheterization and for three other non-cardiac procedures. The scattered radiation distribution resulting from the cardiac catheterization procedure was measured prior to the staff dose measurements. Staff dose measurements included those of the left shoulder, eye, thyroid and hand doses of the cardiologist. In non-cardiac procedures doses to the hands of the radiologist were measured for nephrostomy, fistulogram and percutaneous transluminal angioplasty procedures. Doses to the radiologist or cardiologist were found to be relatively high if correct protection was not observed. (author)

  8. Cost analysis of radiological interventional procedures and reimbursement within a clinic

    International Nuclear Information System (INIS)

    Strotzer, M.; Voelk, M.; Lenhart, M.; Fruend, R.; Feuerbach, S.

    2002-01-01

    Purpose: Analysis of costs for vascular radiological interventions on a per patient basis and comparison with reimbursement based on GOAe(Gebuehrenordnung fuer Aerzte) and DKG-NT (Deutsche Krankenhausgesellschaft-Nebenkostentarif). Material and Methods: The ten procedures most frequently performed within 12 months were evaluated. Personnel costs were derived from precise costs per hour and estimated procedure time for each intervention. Costs for medical devices were included. Reimbursement based on GOAewas calculated using the official conversion factor of 0.114 DM for each specific relative value unit and a multiplication factor of 1.0. The corresponding conversion factor for DKG-NT, determined by the DKG, was 0.168 DM. Results: A total of 832 interventional procedures were included. Marked differences between calculated costs and reimbursement rates were found. Regarding the ten most frequently performed procedures, there was a deficit of 1.06 million DM according GOAedata (factor 1.0) and 0.787 million DM according DKG-NT. The percentage of reimbursement was only 34.2 (GOAe; factor 1.0) and 51.3 (DKG-NT), respectively. Conclusion: Reimbursement of radiological interventional procedures based on GOAeand DKG-NT data is of limited value for economic controlling purposes within a hospital. (orig.) [de

  9. Attention for pediatric interventional radiology

    International Nuclear Information System (INIS)

    Zhu Ming; Cheng Yongde

    2005-01-01

    Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae

  10. Evaluation of patient radiation doses using DAP meter in interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Sam [Dept. of Radiological Technology. Shingu University, Sungnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu Univeristy, Kyushu (Japan)

    2017-03-15

    The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipment in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effective of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were 237.7 Gy·cm{sup 2} in TACE, 17.3 Gy·cm{sup 2} in AVF, 114.1 Gy·cm{sup 2} in LE PTA and STENT, 188.5 Gy·cm{sup 2} in TFCA, 383.5 Gy·cm{sup 2} in Aneurysm Coil, 64.6 Gy·cm{sup 2} in PTBD, 64.6 Gy·cm{sup 2} in Biliary Stent, 22.4 Gy·cm{sup 2} in PCN, 4.3 Gy·cm{sup 2} in Hickman, 2.8 Gy·cm{sup 2} in Chemo-port, 4.4 Gy·cm{sup 2} in Perm-Cather, 17.1 Gy·cm{sup 2} in PCD, and 357.9 Gy·cm{sup 2} in Vis, EMB. Dose reference level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipment and procedures in the interventional radiology procedures, further studies and monitoring are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

  11. Assessment of Patients Radiation Dose During Interventional Radiological Procedure in PPUKM

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Muhammad Isa

    2014-01-01

    Interventional Radiology (IR) is a relatively new subspecialty of radiology. It is subspecialty where minimally invasive procedures are performed under radiological guidance using X-ray. This procedure can deliver high radiation doses compared with other radiological method due to long screening time. Because of these it is important to determine radiation doses received by patients undergoing IR procedures. It is to ensure that the dose is within the range deemed to be saved. A total of 128 patients undergoing IR procedures in PPUKM between 2012 and 2013 were study retrospectively. Dose area product (DAP) meter were used to measure the integral dose for the whole procedures. Mean kerma-area products for abdomen, head, pelvis, and thorax were 243.1, 107.3, 39.05 and 45.7 Gycm 2 , respectively. This study may provide the useful information which can be use to establish baseline patient dose data for dose optimizing study and carried out a recommendation on effective method of patient dose reduction during IR procedures. A more detail results of this study are presented in this paper. (author)

  12. Pediatric interventional radiology: vascular interventions

    International Nuclear Information System (INIS)

    Kandasamy, Devasenathipathy; Gamanagatti, Shivanand; Gupta, Arun Kumar

    2016-01-01

    Pediatric interventional radiology (PIR) comprises a range of minimally invasive diagnostic and therapeutic procedures that are performed using image guidance. PIR has emerged as an essential adjunct to various surgical and medical conditions. Over the years, technology has undergone dramatic and continuous evolution, making this speciality grow. In this review, the authors will discuss various vascular interventional procedures undertaken in pediatric patients. It is challenging for the interventional radiologist to accomplish a successful interventional procedure. There are many vascular interventional radiology procedures which are being performed and have changed the way the diseases are managed. Some of the procedures are life saving and have become the treatment of choice in those patients. The future is indeed bright for the practice and practitioners of pediatric vascular and non-vascular interventions. As more and more of the procedures that are currently being performed in adults get gradually adapted for use in the pediatric population, it may be possible to perform safe and successful interventions in many of the pediatric vascular lesions that are otherwise being referred for surgery. (author)

  13. Interventional Radiology in Paediatrics.

    Science.gov (United States)

    Chippington, Samantha J; Goodwin, Susie J

    2015-01-01

    As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.

  14. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  15. The economics of interventional radiology

    International Nuclear Information System (INIS)

    Price, G.W.

    1988-01-01

    At a time when policy makers and regulators are scheming to reduce the costs and utilization of medical services, interventional radiology is poised for growth. Part of this potential for growth is based on wider acceptance of the procedures performed by interventional radiologists. A second factor in the growth potential is the relative value in cost of these procedures compared with alternative therapies. The author presents a discussion of the differences in the relative value of these procedures when performed by physicians of different specialties. This paper reviews the status of the economic climate in the health care delivery system and the role and potential growth of interventional radiology. This includes a review of current data on the utilization of interventional radiology procedures in the Medicare program. This overview includes a discussion of the initiatives of the federal government which directly impact interventional radiology

  16. Anesthesia for interventional radiology

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.

    1989-01-01

    We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures

  17. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France

    International Nuclear Information System (INIS)

    Etard, Cecile; Bigand, Emeline; Salvat, Cecile; Vidal, Vincent; Beregi, Jean Paul; Hornbeck, Amaury; Greffier, Joel

    2017-01-01

    A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm 2 and 11 mins for cerebral angiography, 35 Gy.cm 2 and 16 mins for biliary drainage, 75 Gy.cm 2 and 6 mins for lower limbs arteriography and 70 Gy.cm 2 and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. (orig.)

  18. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France

    Energy Technology Data Exchange (ETDEWEB)

    Etard, Cecile [Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-Roses (France); French Society of Medical Physicists (SFPM), Paris (France); Bigand, Emeline [French Society of Medical Physicists (SFPM), Paris (France); La Timone University Hospital, Department of Radiology, Marseille Cedex (France); Salvat, Cecile [French Society of Medical Physicists (SFPM), Paris (France); Lariboisiere Hospital, Department of Medical Physics and Radiation Protection, Paris (France); Vidal, Vincent [La Timone University Hospital, Department of Radiology, Marseille Cedex (France); French Society of Radiology (SFR) - Interventional Radiology Federation (FRI), Paris (France); Beregi, Jean Paul [French Society of Radiology (SFR) - Interventional Radiology Federation (FRI), Paris (France); Nimes University Hospital, Medical Imaging Group Nimes, Department of Radiology, Nimes (France); Hornbeck, Amaury [French Society of Medical Physicists (SFPM), Paris (France); Trousseau University Hospital, Department of Pediatric Radiology, Paris (France); Greffier, Joel [French Society of Medical Physicists (SFPM), Paris (France); Nimes University Hospital, Medical Imaging Group Nimes, Department of Radiology, Nimes (France)

    2017-10-15

    A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm{sup 2} and 11 mins for cerebral angiography, 35 Gy.cm{sup 2} and 16 mins for biliary drainage, 75 Gy.cm{sup 2} and 6 mins for lower limbs arteriography and 70 Gy.cm{sup 2} and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. (orig.)

  19. Entrance surface dose in cerebral interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.; Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico); Instituto Nacional de Neurologia y Neurocirugia Manuel Velasco Suarez, 14269 DF (Mexico); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico)

    2012-10-23

    At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  20. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.

    2012-01-01

    At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm 2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm 2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  1. Interventional radiology and undesirable effects

    International Nuclear Information System (INIS)

    Benderitter, M.

    2009-01-01

    As some procedures of interventional radiology are complex and long, doses received by patients can be high and cause undesired effects, notably on the skin or in underlying tissues (particularly in the brain as far as interventional neuroradiology is concerned and in lungs in the case of interventional cardiology). The author briefly discusses some deterministic effects in interventional radiology (influence of dose level, delay of appearance of effects, number of accidents). He briefly comments the diagnosis and treatment of severe radiological burns

  2. Occupational exposure in interventional radiology

    International Nuclear Information System (INIS)

    Oh, H.J.; Lee, K.Y.; Cha, S.H.; Kang, Y.K.; Kim, H.J.; Oh, H.J.

    2003-01-01

    This study was conducted to survey of radiation safety control and to measure occupational radiation exposure dose of staff in interventional radiology in Korea. Interventioanl radiology requires the operator and assisting personnel to remain close to the patient, and thus close to primary beams of radiation. Therefore exposure doses of these personnel are significant from a radiological protection point of view. We surveyed the status of radiation safety on interventional radiology of 72 hospitals. The result were that 119 radiation equipments are using in interventional radiology and 744 staffs are composed of 307 radiologists, 116 residents of radiology, 5 general physicians, 171 radiologic technologists and 145 nurses. 81.4% and 20.2 % of operating physicians are using neck collar protector and goggle respectively. The average radiation dose was measured 0.46±0.15 mSv/10 hours fluoroscopy inside examination room in radiation protection facilities. Occupational radiation exposure data on the staff were assessed in interventional radiology procedures from 8 interventional radiology equipments of 6 university hospitals. The dose measurements were made by placing a thermoluminesent dosimeter(TLD) on various body surface of operation and assistant staff during actual interventional radiology. The measured points were the corner of the eyes, neck(on the thyroid) , wrists, chest(outside and inside of the protector), and back. Average radiation equivalent dose of the corner of left eye and left wrist of operating physicians were 1.19 mSv(0.11∼4.13 mSv)/100 minutes fluoroscopy and 4.32 mSv(0.16∼11.0 mSv)/100 minutes fluoroscopy respectively. Average exposure dose may vary depending on the type of procedure, personal skills and the quality of equipment. These results will be contributed to prepare the guide line in interventional radiology in Korea

  3. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  4. Cardiovascular and interventional radiology

    International Nuclear Information System (INIS)

    White, R.I. Jr.

    1985-01-01

    A symposium of eight short but complete papers giving an overview of interventional radiology is presented. Organized by Dr. William Casarella, this symposium is certainly the most current review of the subject available. This year's cardiovascular section is again heavily weighted toward interventional radiology. Abrams and Doubilet's article on the underutilization of angioplasty is important because it describes the cost effectiveness of this method. Most health planners, right or wrong, have complained about overutilization of diagnostic radiology procedures. In general, the opposite is true for interventional procedures - they are underutilized. If the authors draw the attention of their hospital administrators to these approaches and also produce the data on long-term follow-up for our medical colleagues, interventional radiology may realize its full potential. Articles on cardiac magnetic resonance imaging are beginning to appear and this technique seems to have great potential. An important article, which is the first prospective study comparing lung scintigraphy and pulmonary angiography in the diagnosis of pulmonary embolism, supports the increased use of pulmonary angiography. Finally, an article on complications of percutaneous biliary drainage provokes some discussion of its value for routine preoperative use

  5. Organ doses in interventional radiology procedures: Evaluation of software

    International Nuclear Information System (INIS)

    Tort, I.; Ruiz-Cruces, R.; Perez-Martinez, M.; Carrera, F.; Ojeda, C.; Diez de los Rios, A.

    2001-01-01

    Interventional Radiology (IR) procedures require large fluoroscopy times and important number of radiological images, so the levels of radiation to patient are high, which leads us to calculate the organ doses. The objective of this work is to estimate and make a comparison of the results given by the different software that we have to do the calculation of organ doses in complex procedures of IR. To do this, 28 patients have been selected, distributed in the 3 procedures with highest doses. The determination of organ doses and effective doses has been made using the projections utilized and different software based on Monte Carlo Methods: Eff-dose, PCXMC and Diasoft. We have obtained very high dispersion in the average organ dose between the 3 programs. In many cases, it is higher than 25% and in some particular cases, it is greater than 100%. Dispersion obtained in effective doses is not so high, being under 20% in all cases. This shows that a better solution is needed to solve the problem of the organ doses calculation; a more accurate method is necessary that brings us to a trustworthy approach to reality, and, at the moment, that we do not dispose of it. (author)

  6. Education and training in radiological protection for diagnostic and interventional procedures ICRP 113 in brief

    International Nuclear Information System (INIS)

    Salama, S.; Gomaa, M. A.; Alshoufi, J.H.

    2013-01-01

    The international commission on radiological protection (ICRP) is the primary body in protection against ionizing radiation. Among its latest publication is ICRP publication 113 e ducation and training in radiological protection for diagnostic and interventional procedures . This document introduces diagnostic and interventional medical procedures using ionizing radiations in deep details. The document is approved by the commission in October 2010 and translated into Arabic at December 2011. This work is a continuation of the efforts series to translate some of the most important of the radiological protection references into the Arabic; aiming to maximize the benefit. The previous translation include WHO handbook on indoor radon: a public health perspective, issued by world health organization 2009 and Radiation Protection in Medicine, ICRP Publication 105 2007 that translated into Arabic with support of Arab atomic energy authority at 2011.

  7. Physical and cognitive task analysis in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S [School of Psychology, University of Liverpool, Liverpool (United Kingdom); Healey, A [Royal Liverpool University Hospital, Liverpool (United Kingdom); Evans, J [Royal Liverpool University Hospital, Liverpool (United Kingdom); Murphy, M [Royal Liverpool University Hospital, Liverpool (United Kingdom); Crawshaw, M [Department of Psychology, University of Hull, Hull (United Kingdom); Gould, D [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2006-01-15

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  8. Physical and cognitive task analysis in interventional radiology

    International Nuclear Information System (INIS)

    Johnson, S.; Healey, A.; Evans, J.; Murphy, M.; Crawshaw, M.; Gould, D.

    2006-01-01

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model

  9. The current status of interventional radiology in Canada: results of a survey by the Canadian Interventional Radiology Association

    Energy Technology Data Exchange (ETDEWEB)

    Millward, S.F.; Holley, M.L. [Univ. of Western Ontario, London Health Sciences Centre, Dept. of Radiology, London, Ontario (Canada)

    2001-04-01

    To evaluate the current status of interventional radiology in Canada. A questionnaire was sent to 28 Canadian interventional radiologists (defined as a physician who performs any type of interventional procedure, including biopsies, but excluding interventional neuroradiology) practising in both tertiary and community hospitals in the major centres in all provinces except Prince Edward Island. Twenty-two (79%) of 28 surveys were completed and returned, providing data about 86 interventional radiologists (IRs). IRs were performing almost all of the following procedures at their institutions: inferior vena cava filter placement, venous angioplasty, dialysis fistula angioplasty, diagnostic and therapeutic pulmonary and bronchial artery procedures, diagnostic and therapeutic procedures of the lower extremity and renal arteries, percutaneous abscess and biliary drainage procedures, percutaneous nephrostomy, and fibroid embolization. A second group of procedures, performed by both IRs and non-radiologists in most institutions, included: all types of central venous catheter placements, pleural drainage, and gastrostomy tube placement. Procedures not being performed by anyone in a number of institutions included: dialysis graft thrombolysis, varicocele embolization, transjugular intrahepatic portosystemic shunts, palliative stenting of the gastrointestinal tract, fallopian tube recannalization, and liver and prostate tumour treatments. The factors most often limiting the respondents' ability to provide a comprehensive interventional service were the interventional radiology inventory budget and the availability of interventional radiology rooms; 50% of respondents indicated the number of available nurses, technologists and IRs was also an important limiting factor. IRs in Canada still play a major role in many of the most commonly performed procedures. However, limited availability of resources and personnel in many institutions may be hampering the ability of IRs to

  10. Interventional neuroradiology techniques in interventional radiology

    CERN Document Server

    Murphy, Kieran; Robertson, Fergus; Watkinson, Anthony

    2013-01-01

    This book provides accessible technique-specific information on interventional radiology procedures, in a format suitable for reference in the IR treatment room or as a carry-around guide. Offers step-by-step points, key point summaries and illustrations.

  11. Deterministic effects of interventional radiology procedures

    International Nuclear Information System (INIS)

    Shope, Thomas B.

    1997-01-01

    The purpose of this paper is to describe deterministic radiation injuries reported to the Food and Drug Administration (FDA) that resulted from therapeutic, interventional procedures performed under fluoroscopic guidance, and to investigate the procedure or equipment-related factors that may have contributed to the injury. Reports submitted to the FDA under both mandatory and voluntary reporting requirements which described radiation-induced skin injuries from fluoroscopy were investigated. Serious skin injuries, including moist desquamation and tissues necrosis, have occurred since 1992. These injuries have resulted from a variety of interventional procedures which have required extended periods of fluoroscopy compared to typical diagnostic procedures. Facilities conducting therapeutic interventional procedures need to be aware of the potential for patient radiation injury and take appropriate steps to limit the potential for injury. (author)

  12. A Checklist to Improve Patient Safety in Interventional Radiology

    International Nuclear Information System (INIS)

    Koetser, Inge C. J.; Vries, Eefje N. de; Delden, Otto M. van; Smorenburg, Susanne M.; Boermeester, Marja A.; Lienden, Krijn P. van

    2013-01-01

    To develop a specific RADiological Patient Safety System (RADPASS) checklist for interventional radiology and to assess the effect of this checklist on health care processes of radiological interventions. On the basis of available literature and expert opinion, a prototype checklist was developed. The checklist was adapted on the basis of observation of daily practice in a tertiary referral centre and evaluation by users. To assess the effect of RADPASS, in a series of radiological interventions, all deviations from optimal care were registered before and after implementation of the checklist. In addition, the checklist and its use were evaluated by interviewing all users. The RADPASS checklist has two parts: A (Planning and Preparation) and B (Procedure). The latter part comprises checks just before starting a procedure (B1) and checks concerning the postprocedural care immediately after completion of the procedure (B2). Two cohorts of, respectively, 94 and 101 radiological interventions were observed; the mean percentage of deviations of the optimal process per intervention decreased from 24 % before implementation to 5 % after implementation (p < 0.001). Postponements and cancellations of interventions decreased from 10 % before implementation to 0 % after implementation. Most users agreed that the checklist was user-friendly and increased patient safety awareness and efficiency. The first validated patient safety checklist for interventional radiology was developed. The use of the RADPASS checklist reduced deviations from the optimal process by three quarters and was associated with less procedure postponements.

  13. Safety of Conscious Sedation In Interventional Radiology

    International Nuclear Information System (INIS)

    Arepally, Aravind; Oechsle, Denise; Kirkwood, Sharon; Savader, Scott J.

    2001-01-01

    Purpose: To identify rates of adverse events associated with the use of conscious sedation in interventional radiology.Methods: In a 5-month period, prospective data were collected on patients undergoing conscious sedation for interventional radiology procedures (n = 594). Adverse events were categorized as respiratory, sedative, or major adverse events. Respiratory adverse events were those that required oral airway placement, ambu bag, or jaw thrust. Sedation adverse events were unresponsiveness, oxygen saturation less than 90%, use of flumazenil/naloxone, or agitation. Major adverse events were hypotension, intubation, CPR, or cardiac arrest. The frequency of adverse events for the five most common radiology procedures were determined.Results: The five most common procedures (total n = 541) were biliary tube placement/exchange (n = 182), tunneled catheter placement (n 135), diagnostic arteriography (n = 125), vascular interventions (n = 52), and other catheter insertions (n = 46). Rates for respiratory, sedation, and major adverse events were 4.7%, 4.2%, and 2.0%, respectively. The most frequent major adverse event was hypotension (2.0%). Biliary procedures had the highest rate of total adverse events (p < .05) and respiratory adverse events (p < .05).Conclusion: The frequency of adverse events is low with the use of conscious sedation during interventional procedures. The highest rates occurred during biliary interventions

  14. Dosimetry in Interventional Radiology - Effective Dose Estimation

    International Nuclear Information System (INIS)

    Miljanic, S.; Buls, N.; Clerinx, P.; Jarvinen, H.; Nikodemova, D.; Ranogajec-Komor, M; D'Errico, F.

    2008-01-01

    Interventional radiological procedures can lead to significant radiation doses to patients and to staff members. In order to evaluate the personal doses with respect to the regulatory dose limits, doses measured by dosimeters have to be converted to effective doses (E). Measurement of personal dose equivalent Hp(10) using a single unshielded dosimeter above the lead apron can lead to significant overestimation of the effective dose, while the measurement with dosimeter under the apron can lead to underestimation. To improve the accuracy, measurements with two dosimeters, one above and the other under the apron have been suggested ( d ouble dosimetry ) . The ICRP has recommended that interventional radiology departments develop a policy that staff should wear two dosimeters. The aim of this study was to review the double dosimetry algorithms for the calculation of effective dose in high dose interventional radiology procedures. The results will be used to develop general guidelines for personal dosimetry in interventional radiology procedures. This work has been carried out by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its 6th Framework Program.(author)

  15. Double dosimetry procedures for the determination of occupational effective dose in interventional radiology

    International Nuclear Information System (INIS)

    Jaervinen, H.; Buls, N.; Clerinx, P.; Miljanic, S.; Ranogajec-Komor, M.; Nikodemova, D.; D'Errico, F.

    2008-01-01

    Full text: In interventional radiology, for an accurate determination of occupational effective dose, measurements with two dosemeters ('double dosimetry', DD) have been recommended, one dosemeter located above and one under the protective apron. In this paper, based on an extensive literature search, the most recent algorithms developed for the determination of effective dose from the dosimeter readings have been compared for a few practical interventional procedures. Recommendations on the practices and algorithms are given on the basis of the results. For the comparison of algorithms, dosemeter readings and the effective dose were obtained both experimentally and by calculation. Further, data from published Monte Carlo calculations have been applied. The literature review has indicated that very few regulations for DD exist and the DD practices have not been harmonized. There is no firm consensus on the most suitable calculation algorithms. Single dosemeter (SD) measurements are still mostly used for the calculation of effective dose. Most DD and SD algorithms overestimate effective dose significantly, sometimes by over ten times. However, SD algorithms can significantly underestimate effective dose in certain interventional radiology conditions. Due to the possibility of underestimating effective dose, DD is generally recommended. The results suggest that there might not be a single DD algorithm which would be optimum for all interventional radiology procedures. However, the selection of a precise DD algorithm for each individual condition is not practical and compromises must be made. For accurate personnel dosimetry, the accuracy of the algorithm selected should be tested for typical local interventional radiology condition. Personnel dosemeters should be used in the recommended positions. The dosemeter above the apron should be on a collar and its reading also used to assess the risk of lens injuries. The dosemeter under the apron can be on the chest or

  16. Estimating effective dose to pediatric patients undergoing interventional radiology procedures using anthropomorphic phantoms and MOSFET dosimeters.

    Science.gov (United States)

    Miksys, Nelson; Gordon, Christopher L; Thomas, Karen; Connolly, Bairbre L

    2010-05-01

    The purpose of this study was to estimate the effective doses received by pediatric patients during interventional radiology procedures and to present those doses in "look-up tables" standardized according to minute of fluoroscopy and frame of digital subtraction angiography (DSA). Organ doses were measured with metal oxide semiconductor field effect transistor (MOSFET) dosimeters inserted within three anthropomorphic phantoms, representing children at ages 1, 5, and 10 years, at locations corresponding to radiosensitive organs. The phantoms were exposed to mock interventional radiology procedures of the head, chest, and abdomen using posteroanterior and lateral geometries, varying magnification, and fluoroscopy or DSA exposures. Effective doses were calculated from organ doses recorded by the MOSFET dosimeters and are presented in look-up tables according to the different age groups. The largest effective dose burden for fluoroscopy was recorded for posteroanterior and lateral abdominal procedures (0.2-1.1 mSv/min of fluoroscopy), whereas procedures of the head resulted in the lowest effective doses (0.02-0.08 mSv/min of fluoroscopy). DSA exposures of the abdomen imparted higher doses (0.02-0.07 mSv/DSA frame) than did those involving the head and chest. Patient doses during interventional procedures vary significantly depending on the type of procedure. User-friendly look-up tables may provide a helpful tool for health care providers in estimating effective doses for an individual procedure.

  17. Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff

    International Nuclear Information System (INIS)

    Jaervinen, H.; Buls, N.; Clerinx, P.; Jansen, J.; Miljanic, S.; Nikodemova, D.; Ranogajec-Komor, M.; D'Errico, F.

    2008-01-01

    In interventional radiology, for an accurate determination of effective dose to the staff, measurements with two dosemeters have been recommended, one located above and one under the protective apron. Such 'double dosimetry' practices and the algorithms used for the determination of effective dose were reviewed in this study by circulating a questionnaire and by an extensive literature search. The results indicated that regulations for double dosimetry almost do not exist and there is no firm consensus on the most suitable calculation algorithms. The calculation of effective dose is mainly based on the single dosemeter measurements, in which either personal dose equivalent, directly, (dosemeter below the apron) or a fraction of personal dose equivalent (dosemeter above the apron) is taken as an assessment of effective dose. The most recent studies suggest that there might not be just one double dosimetry algorithm that would be optimum for all interventional radiology procedures. Further investigations in several critical configurations of interventional radiology procedures are needed to assess the suitability of the proposed algorithms. (authors)

  18. Radiology of non-spinal pain procedures. A guide for the interventionalist

    International Nuclear Information System (INIS)

    Syed, Mubin I.; Shaikh, Azin

    2011-01-01

    Most interventionalists are not radiologists and most radiologists do not understand interventional pain procedures. Nevertheless, interventionalists order extensive diagnostic imaging in the workup prior to any intervention. Against this background, this handy, well-illustrated manual has been designed to meet the major need of interventional pain physicians to understand the radiologic imaging involved in the performance of non-spinal pain procedures. It provides information on such topics as radiologic anatomy, the radiologic manifestations of indications and contraindications to interventional procedures, and the radiologic appearance of complications that may arise from these procedures. In addition, it will be useful for the diagnostic radiologist, who may be unaware of many of the interventional pain procedures. The chosen format will ensure that the reader is quickly able to reference any given procedure. Sections are devoted to the head and neck, thorax, abdomen, pelvis, and the upper and lower extremities. As this is a guidebook, it does not encompass every single pathologic entity that may be encountered; however, the commonly performed non-spinal pain procedures are included. This text will prove essential for any interventionalist who does not have easy access to a radiologist and vice versa. (orig.)

  19. Radiology of non-spinal pain procedures. A guide for the interventionalist

    Energy Technology Data Exchange (ETDEWEB)

    Syed, Mubin I. [Dayton Interventional Radiology, Dayton, OH (United States); Shaikh, Azin

    2011-07-01

    Most interventionalists are not radiologists and most radiologists do not understand interventional pain procedures. Nevertheless, interventionalists order extensive diagnostic imaging in the workup prior to any intervention. Against this background, this handy, well-illustrated manual has been designed to meet the major need of interventional pain physicians to understand the radiologic imaging involved in the performance of non-spinal pain procedures. It provides information on such topics as radiologic anatomy, the radiologic manifestations of indications and contraindications to interventional procedures, and the radiologic appearance of complications that may arise from these procedures. In addition, it will be useful for the diagnostic radiologist, who may be unaware of many of the interventional pain procedures. The chosen format will ensure that the reader is quickly able to reference any given procedure. Sections are devoted to the head and neck, thorax, abdomen, pelvis, and the upper and lower extremities. As this is a guidebook, it does not encompass every single pathologic entity that may be encountered; however, the commonly performed non-spinal pain procedures are included. This text will prove essential for any interventionalist who does not have easy access to a radiologist and vice versa. (orig.)

  20. Paediatric interventional radiology

    International Nuclear Information System (INIS)

    McLaren, Clare

    2014-01-01

    Paediatric interventional radiology (PIR) is a rapidly-growing subspecialty, which offers a wide range of procedures applicable to almost all areas of hospital paediatrics. There are many important differences between paediatric and adult practice in interventional radiology, including disease processes and treatment goals, anatomical considerations, periprocedural patient management, radiation exposure optimisation and legal aspects. The use of retrievable or absorbable interventional devices such as stents will probably become more widespread in PIR practice. Recent advances in the technology of imaging equipment have been accompanied by an increase in the complexity of the work done by the radiographer. These developments present challenges and opportunities related to training and maintenance of skills, staffing arrangements, and the potential for advanced practice. It is likely that specialisation in PIR will become a more common role for radiographers in the future

  1. A real-time haptic interface for interventional radiology procedures.

    Science.gov (United States)

    Moix, Thomas; Ilic, Dejan; Fracheboud, Blaise; Zoethout, Jurjen; Bleuler, Hannes

    2005-01-01

    Interventional Radiology (IR) is a minimally-invasive surgery technique (MIS) where guidewires and catheters are steered in the vascular system under X-ray imaging. In order to perform these procedures, a radiologist has to be correctly trained to master hand-eye coordination, instrument manipulation and procedure protocols. This paper proposes a computer-assisted training environment dedicated to IR. The system is composed of a virtual reality (VR) simulation of the anatomy of the patient linked to a robotic interface providing haptic force feedback.The paper focuses on the requirements, design and prototyping of a specific part of the haptic interface dedicated to catheters. Translational tracking and force feedback on the catheter is provided by two cylinders forming a friction drive arrangement. The whole friction can be set in rotation with an additional motor providing torque feedback. A force and a torque sensor are integrated in the cylinders for direct measurement on the catheter enabling disturbance cancellation with a close-loop force control strategy.

  2. Assessment of eye lens doses for workers during interventional radiology procedures

    International Nuclear Information System (INIS)

    Urboniene, A.; Sadzeviciene, E.; Ziliukas, J.

    2015-01-01

    The assessment of eye lens doses for workers during interventional radiology (IR) procedures was performed using a new eye lens dosemeter. In parallel, the results of routine individual monitoring were analysed and compared with the results obtained from measurements with a new eye lens dosemeter. The eye lens doses were assessed using H p (3) measured at the level of the eyes and were compared with H p (10) measured with the whole-body dosemeter above the lead collar. The information about use of protective measures, the number of performed interventional procedures per month and their fluoroscopy time was also collected. The assessment of doses to the lens of the eye was done for 50 IR workers at 9 Lithuanian hospitals for the period of 2012-2013. If the use of lead glasses is not taken into account, the estimated maximum annual dose equivalent to the lens of the eye was 82 mSv. (authors)

  3. Angiography and interventional radiology

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The decrease in angiographic procedures as a result of less invasive imaging modalities has been counterbalanced by the rise in interventional radiological techniques. Because the interventional radiologist behaves somewhat like a surgeon, his legal responsibilities also approach those of his surgical colleagues. The basic concerns of negligent malpractice are amplified by the issues of informed consent and vicarious liability. Also, damages resulting from these procedures are costly because of the severity of the injuries. The angiographer must become versed in medicolegal issues of this rapidly evolving specialty

  4. Training for Radiation Protection in Interventional Radiology

    International Nuclear Information System (INIS)

    Bartal, G.; Sapoval, M.; Ben-Shlomo, A.

    1999-01-01

    Program in radiological equipment has incorporated more powerful x-ray sources into the standard Fluoroscopy and CT systems. Expanding use of interventional procedures carries extensive use of fluoroscopy and CT which are both associated with excessive radiation exposure to the patient and personnel. During cases of Intravenous CT Angiography and direct Intraarterial CT Angiography, one may substitute a substantial number of diagnostic angiography checks. Basic training in interventional radiology hardly includes some of the fundamentals of radiation protection. Radiation Protection in Interventional Radiology must be implemented in daily practice and become an integral part of procedure planning strategy in each and every case. Interventional radiological most master all modern imaging modalities in order to choose the most effective, but least hazardous one. In addition, one must be able to use various imaging techniques (Fluoroscopy, CTA, MM and US) as a stand-alone method, as well as combine two techniques or more. Training programs for fellows: K-based simulation of procedures and radiation protection. Special attention should be taken in the training institutions and a basic training in radiation protection is advised before the trainee is involved in the practical work. Amendment of techniques for balloon and stent deployment with minimal use of fluoroscopy. Attention to the differences between radiation protection in cardiovascular and nonvascular radiology with special measures that must be taken for each one of them (i.e., peripheral angiography vs. stenting, Endo luminal Aortic Stent Graft, or nonvascular procedures such as biliary or endo urological stenting or biliary intervention). A special emphasis should be put on the training techniques of Interventional Radiologists, both beginners and experienced. Patient dose monitoring by maintaining records of fluoroscopic time is better with non-reset timer, but is optional. Lee of automated systems that

  5. Malpractice claims in interventional radiology: frequency, characteristics and protective measures.

    Science.gov (United States)

    Magnavita, N; Fileni, A; Mirk, P; Magnavita, G; Ricci, S; Cotroneo, A R

    2013-04-01

    The use of interventional radiology procedures has considerably increased in recent years, as has the number of related medicolegal litigations. This study aimed to highlight the problems underlying malpractice claims in interventional radiology and to assess the importance of the informed consent process. The authors examined all insurance claims relating to presumed errors in interventional radiology filed by radiologists over a period of 14 years after isolating them from the insurance database of all radiologists registered with the Italian Society of Medical Radiology (SIRM) between 1 January1993 and 31 December 2006. In the period considered, 98 malpractice claims were filed against radiologists who had performed interventional radiology procedures. In 21 cases (21.4%), the event had caused the patient's death. In >80% of cases, the event occurred in a public facility. The risk of a malpractice claim for a radiologist practising interventional procedures is 47 per 1,000, which corresponds to one malpractice claim for each 231 years of activity. Interventional radiology, a discipline with a biological risk profile similar to that of surgery, exposes practitioners to a high risk of medicolegal litigation both because of problems intrinsic to the techniques used and because of the need to operate on severely ill patients with compromised clinical status. Litigation prevention largely depends on both reducing the rate of medical error and providing the patient with correct and coherent information. Adopting good radiological practices, scrupulous review of procedures and efficiency of the instruments used and audit of organisational and management processes are all factors that can help reduce the likelihood of error. Improving communication techniques while safeguarding the patient's right to autonomy also implies adopting clear and rigorous processes for obtaining the patient's informed consent to the medical procedure.

  6. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins

    International Nuclear Information System (INIS)

    Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.

    2012-01-01

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  7. Risk of bleeding associated with interventional musculoskeletal radiology procedures. A comprehensive review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Foremny, Gregory B.; Jose, Jean; Subhawong, Ty K. [University of Miami Miller School of Medicine, Department of Radiology, Jackson Memorial Hospital, Miami, FL (United States); Pretell-Mazzini, Juan [University of Miami Miller School of Medicine, Department of Orthopaedic Surgery-Division of Musculoskeletal Oncology, Miami, FL (United States)

    2015-05-01

    This review compiles the current literature on the bleeding risks in common musculoskeletal interventional procedures and attempts to provide guidance for practicing radiologists in making decisions regarding the periprocedural management of patients on antithrombotic therapy. The practitioner must weigh the risk of bleeding if therapy is continued against the possibility a thromboembolic occurring if anticoagulation therapy is withheld or reversed. Unfortunately, there is little empirical data to guide evidence-based decisions for many musculoskeletal interventions. However, a review of the literature shows that for low-risk procedures, such as arthrograms/arthrocenteses or muscle/tendon sheath injections, bleeding risks are sufficiently small that anticoagulants and antiplatelet therapies need not be withheld. Additionally, relatively higher-risk procedures, such as needle biopsies of bone and soft tissue, may be safely performed without holding antithrombotic therapy, provided pre-procedural INR is within therapeutic range. Thus, while a patient's particular clinical circumstances should dictate optimal individualized management, anticoagulation alone is not a general contraindication to most interventional musculoskeletal radiology procedures. (orig.)

  8. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology

    International Nuclear Information System (INIS)

    Vano, E.; Sanchez, R.M.; Fernandez, J.M.

    2015-01-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 μSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm 2 , respectively. The median ratios for dosemeters worn over the apron by operators ( protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 μSv Gy -1 cm -2 , respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y -1 and per operator were necessary to reach the new lens dose limit for the three interventional specialties. (authors)

  9. Interventional radiography and mortality risks in U.S. radiologic technologists

    Energy Technology Data Exchange (ETDEWEB)

    Linet, Martha S.; Freedman, D.M.; Sigurdson, Alice J.; Doody, Michele M. [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Hauptmann, Michael [National Cancer Institute, Biostatistics Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Alexander, Bruce H. [University of Minnesota, Division of Environmental Health Sciences, Minneapolis, MN (United States); Miller, Jeremy [Information Management Services, Inc., Rockville, MD (United States)

    2006-09-15

    With the exponential increase in minimally invasive fluoroscopically guided interventional radiologic procedures, concern has increased about the health effects on staff and patients of radiation exposure from these procedures. There has been no systematic epidemiologic investigation to quantify serious disease risks or mortality. To quantify all-cause, circulatory system disease and cancer mortality risks in U.S. radiologic technologists who work with interventional radiographic procedures, we evaluated mortality risks in a nationwide cohort of 88,766 U.S. radiologic technologists (77% female) who completed a self-administered questionnaire during 1994-1998 and were followed through 31 December 2003. We obtained information on work experience, types of procedures (including fluoroscopically guided interventional procedures), and protective measures plus medical, family cancer history, lifestyle, and reproductive information. Cox proportional hazards regression models were used to compute relative risks (RRs) with 95% confidence intervals (CIs). Between completion of the questionnaire and the end of follow-up, there were 3,581 deaths, including 1,209 from malignancies and 979 from circulatory system diseases. Compared to radiologic technologists who never or rarely performed or assisted with fluoroscopically guided interventional procedures, all-cause mortality risks were not increased among those working on such procedures daily. Similarly, there was no increased risk of mortality resulting from all circulatory system diseases combined, all cancers combined, or female breast cancer among technologists who daily performed or assisted with fluoroscopically guided interventional procedures. Based on small numbers of deaths (n=151), there were non-significant excesses (40%-70%) in mortality from cerebrovascular disease among technologists ever working with these procedures. The absence of significantly elevated mortality risks in radiologic technologists reporting the

  10. ICRP PUBLICATION 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology

    International Nuclear Information System (INIS)

    Khong, P-L.; Ringertz, H.; Donoghue, V.; Frush, D.; Rehani, M.; Appelgate, K.; Sanchez, R.

    2013-01-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities – radiography and fluoroscopy, interventional radiology, and computed tomography – are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation

  11. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  12. Training in Radiation Protection for Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vano, E.; Guibelalde, E.

    2002-07-01

    Several potential problems have been detected in the safety aspects for the practice of interventional radiology procedures: a) An important increase in the number cases and their complexity and the corresponding increase of installations and specialists involved; b) New X ray systems more sophisticated, with advanced operational possibilities, requiring special skills in the operators to obtain the expected benefits;c) New medical specialists arriving to the interventional arena to profit the benefits of the interventional techniques without previous experience in radiation protection. For that reason, education and training is one of the basic areas in any optimisation programme in radiation protection (RP). the medical field and especially interventional radiology requires actions to promote and to profit the benefit of the new emerging technologies for training (Internet, electronic books, etc). The EC has recently sponsored the MARTIR programme (Multimedia and Audio-visual Radiation Protection Training in Interventional Radiology) with the production of two videos on basic aspects of RP and quality control and one interactive CD-ROM to allow tailored individual training programmes. those educational tools are being distributed cost free in the main European languages. To go ahead with these actions, the EC has decided to promote during 2002, a forum with the main Medical European Societies involved in these interventional procedures. (Author)

  13. Training in Radiation Protection for Interventional Radiology

    International Nuclear Information System (INIS)

    Vano, E.; Guibelalde, E.

    2002-01-01

    Several potential problems have been detected in the safety aspects for the practice of interventional radiology procedures: a) An important increase in the number cases and their complexity and the corresponding increase of installations and specialists involved; b) New X ray systems more sophisticated, with advanced operational possibilities, requiring special skills in the operators to obtain the expected benefits;c) New medical specialists arriving to the interventional arena to profit the benefits of the interventional techniques without previous experience in radiation protection. For that reason, education and training is one of the basic areas in any optimisation programme in radiation protection (RP). the medical field and especially interventional radiology requires actions to promote and to profit the benefit of the new emerging technologies for training (Internet, electronic books, etc). The EC has recently sponsored the MARTIR programme (Multimedia and Audio-visual Radiation Protection Training in Interventional Radiology) with the production of two videos on basic aspects of RP and quality control and one interactive CD-ROM to allow tailored individual training programmes. those educational tools are being distributed cost free in the main European languages. To go ahead with these actions, the EC has decided to promote during 2002, a forum with the main Medical European Societies involved in these interventional procedures. (Author)

  14. Pediatric interventional radiology clinic - how are we doing?

    International Nuclear Information System (INIS)

    Rubenstein, Jonathan; Zettel, Julie C.; Lee, Eric; Cote, Michelle; Aziza, Albert; Connolly, Bairbre L.

    2016-01-01

    Development of a pediatric interventional radiology clinic is a necessary component of providing a pediatric interventional radiology service. Patient satisfaction is important when providing efficient, high-quality care. To analyze the care provided by a pediatric interventional radiology clinic from the perspective of efficiency and parent satisfaction, so as to identify areas for improvement. The prospective study was both quantitative and qualitative. The quantitative component measured clinic efficiency (waiting times, duration of clinic visit, nurse/physician time allocation and assessments performed; n = 91). The qualitative component assessed parental satisfaction with their experience with the pediatric interventional radiology clinic, using a questionnaire (5-point Likert scale) and optional free text section for feedback (n = 80). Questions explored the family's perception of relevance of information provided, consent process and overall satisfaction with their pediatric interventional radiology clinic experience. Families waited a mean of 11 and 10 min to meet the physician and nurse, respectively. Nurses and physicians spent a mean of 28 and 21 min with the families, respectively. The average duration of the pediatric interventional radiology clinic consultation was 56 min. Of 80 survey participants, 83% were satisfied with their experience and 94% said they believed providing consent before the day of the procedure was helpful. Only 5% of respondents were not satisfied with the time-efficiency of the interventional radiology clinic. Results show the majority of patients/parents are very satisfied with the pediatric interventional radiology clinic visit. The efficiency of the pediatric interventional radiology clinic is satisfactory; however, adherence to stricter scheduling can be improved. (orig.)

  15. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.

    Science.gov (United States)

    Vano, E; Sanchez, R M; Fernandez, J M

    2015-07-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Dose evaluation in medical staff during diagnostics procedures in interventional radiology; Avaliacao da dose na equipe medica durante procedimentos diagnoticos de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, Fernando A.; Alves, Allan F.F.; Rosa, Maria E.D.; Miranda, Jose R.A. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias. Departamento de Fisica e Biofisica; Moura, Regina [Faculdade de Medicina de Botucatu, SP (Brazil). Departamento de Cirurgia e Ortopedia; Pina, Diana R., E-mail: bacchim@ibb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Doencas Tropicais e Diagnostico por Imagem

    2014-08-15

    Studies show that personal dosimeters may underestimate the dose values in interventional physicians, especially in extremities and crystalline. The objective of this work was to study the radiation exposure levels of medical staff in diagnostic interventional radiology procedures. For this purpose LiF:Mg,Ti (TLD-100) dosimeters were placed in different regions of the physician body. When comparing with reference dose levels, the maximum numbers of annual procedures were found. This information is essential to ensure the radiological protection of those professionals. (author)

  17. New era of the relationship between Chinese interventional radiology sub-society and journal of interventional radiology

    International Nuclear Information System (INIS)

    Li Linsun

    2009-01-01

    The past decades have witnessed interventional radiology in China to go from a very initial clinical practice to an important medical player in modern medicine. Recently, a friendly collaboration has been successfully established between the Chinese Interventional Radiology Sub-society and the Journal of Interventional Radiology. The Chinese Interventional Radiology Sub-society will take the full responsibility for the academic governance of the Journal of Interventional Radiology and the Journal of Interventional Radiology will formally become the sole interventional academic periodical of the Chinese Interventional Radiology Sub-society in China. This collaboration will surely make Chinese interventional radiology to initiate a new era,promote the further development of interventional radiology at home and enable the Journal of Interventional Radiology to step into the international medical circle. (authors)

  18. Active pixel as dosimetric device for interventional radiology

    International Nuclear Information System (INIS)

    Servoli, L.; Baldaccini, F.; Biasini, M.; Checcucci, B.; Chiocchini, S.; Cicioni, R.; Conti, E.; Di Lorenzo, R.; Dipilato, A.C.; Esposito, A.; Fanó, L.; Paolucci, M.; Passeri, D.; Pentiricci, A.

    2013-01-01

    Interventional Radiology (IR) is a subspecialty of radiology comprehensive of all minimally invasive diagnostic and therapeutic procedures performed using radiological devices to obtain image guidance. The interventional procedures are potentially harmful for interventional radiologists and medical staff due to the X-ray diffusion by the patient's body. The characteristic energy range of the diffused photons spans few tens of keV. In this work we will present a proposal for a new X-ray sensing element in the energy range of interest for IR procedures. The sensing element will then be assembled in a dosimeter prototype, capable of real-time measurement, packaged in a small form-factor, with wireless communication and no external power supply to be used for individual operators dosimetry for IR procedures. For the sensor, which is the heart of the system, we considered three different Active Pixel Sensors (APS). They have shown a good capability as single X-ray photon detectors, up to several tens keV photon energy. Two dosimetric quantities have been considered, the number of detected photons and the measured energy deposition. Both observables have a linear dependence with the dose, as measured by commercial dosimeters. The uncertainties in the measurement are dominated by statistic and can be pushed at ∼5% for all the sensors under test

  19. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  20. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  1. Acute radiologic intervention in gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Lesak, F.

    1986-01-01

    A case of embolization of the gastroduodenal artery in a 38-year old man with chronic pancreatitis and uncontrollable bleeding is presented. The advantage of this interventional radiologic procedure is discussed and in selective cases it seems to be the choice of treatment.

  2. [Radiation protection in interventional radiology].

    Science.gov (United States)

    Adamus, R; Loose, R; Wucherer, M; Uder, M; Galster, M

    2016-03-01

    The application of ionizing radiation in medicine seems to be a safe procedure for patients as well as for occupational exposition to personnel. The developments in interventional radiology with fluoroscopy and dose-intensive interventions require intensified radiation protection. It is recommended that all available tools should be used for this purpose. Besides the options for instruments, x‑ray protection at the intervention table must be intensively practiced with lead aprons and mounted lead glass. A special focus on eye protection to prevent cataracts is also recommended. The development of cataracts might no longer be deterministic, as confirmed by new data; therefore, the International Commission on Radiological Protection (ICRP) has lowered the threshold dose value for eyes from 150 mSv/year to 20 mSv/year. Measurements show that the new values can be achieved by applying all X‑ray protection measures plus lead-containing eyeglasses.

  3. White Paper: Curriculum in Interventional Radiology.

    Science.gov (United States)

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Patient dosimetry in interventional radiology

    International Nuclear Information System (INIS)

    Silva, Mauro Wilson O. da; Canevaro, Lucia V.; Rodrigues, Barbara Beatriz D.

    2009-01-01

    Mapping skin doses in interventional radiology is useful to determine the probability of a possible injury, to detect areas of overlapping field and to obtain a permanent register of the most exposed skin areas. A method for the evaluation of patient doses in interventional radiology procedures is the slow film, Kodak EDR2 (Extended Dose Range). Kodak EDR 2 film was calibrated in the range of 50 kVp to 120 kVp beam qualities. Its dose-response curve was plotted up to the saturation point of 1000 mGy. Dose responses are a function of facility dependent factors including processing conditions the density sampling, and exposure monitoring equipment. The distribution and the form of all the irradiation fields have been registered in the Kodak EDR 2 films. The Dosimetric analysis was performed in a sample of 37 patients submitted the procedures coronariography and angioplasty. The film has a threshold of saturation around 1 Gy, the applied methodology is efficient to quantify the doses and to identify the distribution of the fields. (author)

  5. Acute radiologic intervention in gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Lesak, F.

    1986-01-01

    A case of embolization of the gastroduodenal artery in a 38-year old man with chronic pancreatitis and uncontrollable bleeding is presented. The advantage of this interventional radiologic procedure is discussed and in selective cases it seems to be the choice of treatment. (orig.) [de

  6. Contrast media properties in interventional radiology

    International Nuclear Information System (INIS)

    Laerum, F.; Enge, I.

    1989-01-01

    Potential hazards of the use of contrast media (CM) in interventional radiology are analyzed by looking into each procedure regarding interactions of CM with pharmaceutical additives, with technical equipment possibly affecting CM stability, and special local or systemic demands related to the procedure. Also the impact of these factors upon the physiological mechanisms are taken into account. (H.W.). 32 refs.; 4 figs.; 2 tabs

  7. Radiation safety concerns during interventional radiology

    International Nuclear Information System (INIS)

    Victor Raj, D.; Livingstone, Roshan Samuel

    2001-01-01

    Interventional radiological procedures are on the increase by virtue of the fact that these procedures replace highly invasive surgical and other procedures. Radiation dose to patients and hospital workers are of significance since these procedures tend to impart large dose to them. Moreover, long term risk from radiation absorbed by patients is of concern since the life expectancy of major fraction of patients is long after undergoing the procedure. This study intends to measure radiation dose imparted to patients as well as personnel- radiologists, technologists, nurses, etc. and estimate the risk factor involved

  8. Anesthesia Practice and Clinical Trends in Interventional Radiology: A European Survey

    International Nuclear Information System (INIS)

    Haslam, Philip J.; Yap, Bernard; Mueller, Peter R.; Lee, Michael J.

    2000-01-01

    Purpose: To determine current European practice in interventional radiology regarding nursing care, anesthesia, and clinical care trends.Methods: A survey was sent to 977 European interventional radiologists to assess the use of sedoanalgesia, nursing care, monitoring equipment, pre- and postprocedural care, and clinical trends in interventional radiology. Patterns of sedoanalgesia were recorded for both vascular and visceral interventional procedures. Responders rated their preferred level of sedoanalgesia for each procedure as follows: (a) awake/alert, (b) drowsy/arousable, (c) asleep/arousable, (d) deep sedation, and (e) general anesthesia. Sedoanalgesic drugs and patient care trends were also recorded. A comparison was performed with data derived from a similar survey of interventional practice in the United States.Results: Two hundred and forty-three of 977 radiologists responded (25%). The total number of procedures analyzed was 210,194. The majority (56%) of diagnostic and therapeutic vascular procedures were performed at the awake/alert level of sedation, 32% were performed at the drowsy/arousable level, and 12% at deeper levels of sedation. The majority of visceral interventional procedures were performed at the drowsy/arousable level of sedation (41%), 29% were performed at deeper levels of sedation, and 30% at the awake/alert level. In general, more sedoanalgesia is used in the United States. Eighty-three percent of respondents reported the use of a full-time radiology nurse, 67% used routine blood pressure/pulse oximetry monitoring, and 46% reported the presence of a dedicated recovery area. Forty-nine percent reported daily patient rounds, 30% had inpatient hospital beds, and 51% had day case beds.Conclusion: This survey shows clear differences in the use of sedation for vascular and visceral interventional procedures. Many, often complex, procedures are performed at the awake/alert level of sedation in Europe, whereas deeper levels of sedation are

  9. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  10. Patient radiation doses and reference levels in pediatric interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Habib Geryes, Bouchra; Lachaux, Julie; Boddaert, Nathalie; Brunelle, Francis [Hopital Universitaire Necker Enfants Malades, Department of Paediatric Radiology, Paris (France); Bak, Adeline; Ozanne, Augustin; Saliou, Guillaume [Hopital Bicetre, Hopitaux Universitaires Paris-Sud, Department of Neuroradiology, Le Kremlin Bicetre (France); Naggara, Olivier [Hopital Universitaire Necker Enfants Malades, Department of Paediatric Radiology, Paris (France); Centre Hospitalier Sainte-Anne, Universite Paris Descartes Sorbonne Paris Cite, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasculaire, Paris (France); Centre Hospitalier Sainte-Anne, Department of Neuroradiology, Universite Paris Descartes, Sorbonne Paris Cite, INSERM UMR894, Paris (France)

    2017-09-15

    To describe, in a multicentric paediatric population, reference levels (RLs) for three interventional radiological procedures. From January 2012 to March 2015, children scheduled for an interventional radiological procedure in two French tertiary centres were retrospectively included and divided into four groups according to age: children younger than 2 years (A1), aged 2-7 years (A5), 8-12 years (A10) and 13-18 years (A15). Three procedures were identified: cerebral digital subtraction angiography (DSA), brain arteriovenous malformation (bAVM) embolization, and head and neck superficial vascular malformation (SVM) percutaneous sclerotherapy. Demographic and dosimetric data, including dose area product (DAP), were collected. 550 procedures were included. For DSA (162 procedures), the proposed RL values in DAP were 4, 18, 12 and 32 Gy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. For bAVM embolization (258 procedures), values were 33, 70, 105 and 88 Gy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. For SVM sclerotherapy (130 procedures), values were 350, 790, 490 and 248 mGy.cm{sup 2} in groups A1, A5, A10 and A15, respectively. Consecutive data were available to permit a proposal of reference levels for three major paediatric interventional radiology procedures. (orig.)

  11. The role of interventional radiology in obstetric and gynaecology practice

    International Nuclear Information System (INIS)

    Ganeshan, Arul; Nazir, Sarfraz Ahmed; Hon, Lye Quen; Upponi, Sara S.; Foley, Peter; Warakaulle, Dinuke R.; Uberoi, Raman

    2010-01-01

    Interventional radiology is continuing to reshape current practice in many specialties of clinical care. It is a relatively new and innovative branch of medicine in which physicians treat diseases non-operatively through small catheters guided to the target by fluoroscopic and other imaging modalities. The aim is to provide image-guided, minimally invasive alternatives to traditional surgical and medical procedures in suitable cohorts of patients. Procedures which previously required major surgery can now be performed by interventional radiologists, sometimes on an outpatient basis, with little patient discomfort. In this review, we highlight the importance of interventional radiology in treating a comprehensive range of obstetric and gynaecological pathologies.

  12. Protection of staff in interventional radiology

    International Nuclear Information System (INIS)

    Melkamu, M. A.

    2013-04-01

    This project focuses on the interventional radiology. The main objective of this project work was to provide a guidance and advice for occupational exposure and hospital management to optimize radiation protection safety and endorse safety culture. It provides practical information on how to minimize occupational exposure in interventional radiology. In the literature review all considerable parameters to reduce dose to the occupationally exposed are well discussed. These parameters include dose limit, risk estimation, use of dosimeter, personal dose record keeping, analysis of surveillance of occupational dose, investigation levels, and proper use of radiation protection tools and finally about scatter radiation dose rate. In addition the project discusses the ways to reduce occupational exposure in interventional radiology. The methods for dose reduction are minimizing fluoroscopic time, minimizing the number of fluoroscopic image, use of patient dose reduction technologies, use of collimation, planning interventional procedures, positioning in low scattered areas, use of protective shielding, use of appropriate fluoroscopic imaging equipment, giving training for the staff, wearing the dosimeters and know their own dose regularly, and management commitment to quality assurance and quality control system and optimization of radiation protection of safety. (author)

  13. Pediatric interventional radiology: Indications, techniques, and management

    International Nuclear Information System (INIS)

    Towbin, R.B.; Ball, W.S. Jr.

    1987-01-01

    This course develops a practical approach to pediatric interventional radiology. Radiologic intervention in the pediatricage group is possible by attending to the care and special needs of the child. The authors also emphasize their approach to patient preparation, sedation and anesthesia, nursing care, monitoring of the patient during the procedure, and follow-up care. The course is divided into nonvascular and vascular sections. The discussion of nonvascular procedures focus on the chest and the GU and GI systems. Biopsy techniques and drainage of effusions and abscesses within the chest are discussed. A variety of GU procedures are presented including insertion of a nephrostomy tube and percutaneous tract dilation for placement of internal stents, percutaneous stone removal, and percutaneous surgery for pyeloplasty. The authors approach to percutaneous pyeloplasty is briefly discussed. Intervention within the GI system includes percutaenous aspiration, drainage, and biopsies. Emphasis is placed on the selection of embolic agents and catheter delivery systems, techniques, and current treatment concepts. The authors describe experience with embolization of vascular malformations, renovascular disease, uncontrollable hemorrhage, and selected neoplastic processes. Comments on the indications for and techniques of transluminal angioplasty and fibrinolytic therapy in children conclude the lecture

  14. Practical aspects of radiation protection in interventional radiology

    International Nuclear Information System (INIS)

    Faulkner, K.; Vano, E.; Ortiz, P.; Ruiz, R.

    2000-01-01

    The rise in the frequency of interventional procedures over recent years is due to the significant benefits of interventional radiology in which the patient may often be treated as an out-patient for clinical conditions, which would have previously meant that the patient would need surgery, i.e., a more traumatic and expensive treatment. Patients and the public demand greater access to interventional radiology for the these reasons. In some circumstances, for example in neuroradiology the aneurysm may be inoperable surgically and interventional radiology is the only method of treatment. The growth in interventional radiology therefore reflects an drive towards better, safer and more cost effective medicine. Certain types of interventional radiology procedures are quite complicated and may involve the use of extended fluoroscopy times and the use of high dose rates. In some cases reappearance of the original disease may lead to repeated interventions. This combination together with a lack of quality control in x-ray systems, has led deterministic effects in the skin of patients ranging from transient erythema to necrosis. In a few cases, staff doses reached the levels of deterministic effects, such as dot-like sub-capsular opacities (cataracts) and small dot-like paranuclear opacities and discrete posterior sub-capsular condensations in both eyes. A close review of the reported cases reveals that the working conditions were extreme, mainly: a) very short distance from x-ray focus to the patient, collimator in direct contact with the skin, b) use of high dose rate mode for a time much longer than necessary, c) fixed projection exposing the same area of skin during the entire procedure and d) malfunction of automatic exposure control systems. From these lessons, measure for preventing deterministic effects are straightforward: a) placing the x-ray tube at a distance of 50 cm or more from the skin whenever possible, b) placing the image intensifier as close as possible

  15. Report by the work-group on radiation protection in interventional radiology. Recommendations related to the improvement of radiation protection in interventional radiology

    International Nuclear Information System (INIS)

    2010-01-01

    This report aims at proposing recommendations for the improvement of the quality of radiation protection of workers and patients in the field of interventional radiology. These recommendations concern the training of health personnel, the application of the optimization principle to health professionals and patients, dosimetry and the definition of diagnosis reference levels. More particularly, these recommendations concern professions involved in interventional radiology, and take into account the experience of other European Union State members and recommendations made by the IAEA. The authors analyze the equipment, radiological actions, procedures and doses, practitioners, equipment used for radio-guided interventions. They discuss doses received by patients, patient monitoring and radio-induced lesions. Then, they address the role and training of the different interveners in radiation protection, the equipment maintenance issue, and personnel dosimetry and protection

  16. Anesthesia Practices for Interventional Radiology in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Vari, Alessandra, E-mail: alessandra.vari@uniroma1.it [University La Sapienza, Department of Anesthesiology, Intensive Care and Pain Medicine (Italy); Gangi, Afshin, E-mail: gangi@unistra.fr [Les Hôpitaux Universitaires de Strasbourg, Chef de Pôle, Imagerie (France)

    2017-06-15

    PurposeThe Cardiovascular and Interventional Radiological Society of Europe (CIRSE) prompted an initiative to frame the current European status of anesthetic practices for interventional radiology, in consideration of the current variability of IR suite settings, staffing and anesthetic practices reported in the literature and of the growing debate on sedation administered by non-anesthesiologists, in Europe.MethodsAnonymous online survey available to all European CIRSE members to assess IR setting, demographics, peri-procedural care, anesthetic management, resources and staffing, pain management, data collection, safety, management of emergencies and personal opinions on the role CIRSE should have in promoting anesthetic care for interventional radiology.ResultsPredictable differences between countries and national regulations were confirmed, showing how significantly many “local” factors (type and size of centers, the availability of dedicated inpatient bed, availability of anesthesia staff) can affect the routine practice and the expansion of IR as a subspecialty. In addition, the perception of the need for IR to acquire more sedation-related skills is definitely stronger for those who practice with the lowest availability of anesthesia care.ConclusionSignificant country variations and regulations along with a controversial position of the anesthesia community on the issue of sedation administered by non-anesthesiologists substantially represent the biggest drawbacks for the expansion of peri-procedural anesthetic care for IR and for potential initiatives at an European level.

  17. STRAPIR, an European initiative for optimizing radiation protection in interventional radiology

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Loon, R. van; Padovani, R.; Maccia, C.; Eggermont, G.

    1997-01-01

    In 1995, a European initiative for optimizing radiation protection in interventional radiology was proposed by 8 research groups. The project acronym was STPAPIR (Staff Radiation Protection in Interventional Radiology). Interventional Radiology involves an important number of specialists and their risk level is not well known, since dosimetric records exhibit important discrepancies. Many professionals using these techniques are not radiologists and the basic rules of radiation protection, known by radiologists, are not always correctly and completely followed, hence the use of protection devices is not as regular as desirable. Additionally, x-ray systems not specifically designed for interventional procedures are still used in many hospitals, what entails a significant occupational risk increase to the specialists. Some relevant questions for regulatory bodies are presented, namely, reliability of the actual data banks for occupational dosimetry, use of two personal dosimeters for assessing effective dose, actions to strengthen the systematic use of personal dosimeters and protection tools, proposals for specific training in radiation protection and use of x-ray systems specifically designed for interventional procedures, publication of reports about accidents and incidents, are also discussed. (author)

  18. Interventional vascular radiology

    International Nuclear Information System (INIS)

    Yune, H.Y.

    1984-01-01

    The papers published during this past year in the area of interventional vascular radiology presented some useful modifications and further experiences both in the area of thromboembolic therapy and in dilation and thrombolysis, but no new techniques. As an introductory subject, an excellent monograph reviewing the current spectrum of pharmacoangiography was presented in Radiographics. Although the presented material is primarily in diagnostic application of various pharmacologic agents used today to facilitate demonstration of certain diagnostic criteria of various disease processes, both vasodilatory and vasoconstrictive reaction to these agents are widely used in various therapeutic vascular procedures. This monograph should be reviewed by every angiographer whether or not he or she performs interventional procedures, and it would be very convenient to have this table available in the angiography suite. In a related subject, Bookstein and co-workers have written an excellent review concerning pharmacologic manipulations of various blood coagulative parameters during angiography. Understanding the proper method of manipulation of the bloodclotting factors during angiography, and especially during interventional angiography, is extremely important. Particularly, the method of manipulating the coagulation with the use of heparin and protamine and modification of the platelet activity by using aspirin and dipyridamole are succinctly reviewed. The systemic and selective thrombolytic activities of streptokianse are also discussed

  19. Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures

    International Nuclear Information System (INIS)

    Ohuchi, H.; Satoh, T.; Eguchi, Y.; Mori, K.

    2005-01-01

    A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of photostimulated luminescence materials, have a linear dose response up to ∼100 Gy, can accurately measure doses from 1 μGy to 10 Gy and can be used repeatedly. Because the energy dependence of IPs is rather high, the IPs were characterised in this study and a sensitivity variation of ∼13% was observed for effective energies of 32.7 to 44.7 keV, which are used in IR procedures. Simulation of actual interventional cardiology procedures showed that the variation of sensitivity was within 5%, meaning that IPs are practical for measuring skin doses during IR. Moreover, the patient data can be stored online and easily called up when IR procedures must be repeated, helping to prevent radiation injuries. (authors)

  20. Interventional Radiology of Male Varicocele: Current Status

    International Nuclear Information System (INIS)

    Iaccarino, Vittorio; Venetucci, Pietro

    2012-01-01

    Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

  1. Interventional Radiology of Male Varicocele: Current Status

    Energy Technology Data Exchange (ETDEWEB)

    Iaccarino, Vittorio, E-mail: vittorio.iaccarino@unina.it; Venetucci, Pietro [University of Naples ' Federico II' , Diagnostic Imaging Department-Cardiovascular and Interventional Radiology, School of Medicine (Italy)

    2012-12-15

    Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

  2. Dosimetry with slow films in Interventional Radiology

    International Nuclear Information System (INIS)

    Ten, J.I.; Guibelalde, E.; Fernandez, J.M.; Canevaro, L.; Ramirez, R.; Vano, E.

    1998-01-01

    In this work it is presented a method for evaluation of patients doses in Interventional Radiology (RI). The method proposed in this work allows the simultaneous valoration of the product dose-area (PDA), the dose in the patient skin (DES) and the distribution of the irradiated fields, all of they together with their corresponding dose levels. The latter sometimes can be essential since the possible damages in skin depend not only of the doses, but also the irradiated area. The method has been resulted adequate for to evaluate doses to patients in Interventional Radiology procedures. It was possible to apply it as a routine form seeing that its not interfering significantly in the normal development of the medical intervention. The fundamental advantages of this dosimetric method in relation with the unique PDA measure or with the utilization of TLD is that it provide information about the total irradiated area, distribution and length of fields, collimation and wedge used besides that allow to determine the most irradiated zone. The visualization of the irradiated regions and the length fields utilized suggest the possibility to optimize the realization protocols of the interventional procedure in the cases in which it is considered that the doses have been very elevated. (Author)

  3. Radiation dose to physicians’ eye lens during interventional radiology

    International Nuclear Information System (INIS)

    Bahruddin, N A; Hashim, S; Karim, M K A; Ang, W C; Salehhon, N; Sabarudin, A; Bakar, K A

    2016-01-01

    The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure. (paper)

  4. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Safari, M. J.; Wong, J. H. D.; Ng, K. H., E-mail: ngkh@um.edu.my [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603 (Malaysia); Jong, W. L. [Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603 (Malaysia); Cutajar, D. L.; Rosenfeld, A. B. [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2015-05-15

    Purpose: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. Methods: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. Results: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (±1%), field size (±1%), frame rate (±3%), or beam energy (±5%). The detector angular dependence was within ±5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ±3%. Conclusions: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.

  5. Deepening the reform of interventional radiology education and speeding up the development of interventional radiology

    International Nuclear Information System (INIS)

    Lu Chuan; Liu Linxiang; Cheng Yongde

    2010-01-01

    For recent years, although interventional radiology in China has achieved rapid development, it is still facing some rigorous challenges, such as the lack of personnel in interventional field and the flowing-away of certain patients who are definitely suitable for interventional therapy. This paper aims to discuss the reform of interventional radiology education for the undergraduates, postgraduates and clinical practitioners in the medical colleges in order to seek effective solutions to these issues the interventional radiology has confronted with. (authors)

  6. Controlling radiation exposure during interventional procedures in childhood cancer patients

    International Nuclear Information System (INIS)

    Racadio, John M.

    2009-01-01

    Many pediatric cancer patients undergo multiple diagnostic and therapeutic radiologic procedures over the course of their illnesses and are therefore at high risk for radiation exposure. There are a variety of measures that radiologists can employ to reduce this risk. These include limiting the use of radiation whenever possible, using specific strategies to reduce radiation exposure during interventional procedures, using quality assurance programs to ensure compliance, and maintaining continuing staff radiation safety educational programs. Some of the diagnostic and therapeutic interventional radiologic procedures that are performed in pediatric oncology patients are discussed here, along with specific tips for managing radiation exposure. (orig.)

  7. A method to reduce patient's eye lens dose in neuro-interventional radiology procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Sani, F.M.; Ng, K.H.

    2016-01-01

    Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients’ eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system. - Highlights: • The eye protector can considerably reduce the patient's eye lens dose during neuro-interventional procedures. • This protector does not significantly perturb the fluoroscopy image and was completely invisible on the acquisition image due to image subtraction. • The eye protector does not significantly change the exposure parameters (kV and mAs).

  8. Practical interventional radiology

    International Nuclear Information System (INIS)

    Lammer, J.; Schreyer, H.

    1991-01-01

    The book is intended as a practical guide and manual for interventional radiology applications. Main emphasis is placed on the performance of the various techniques, with explanations of the various steps to be taken, illustrated by drawings or pictures. Indications, contra-indications and clinical achievements are given in brief. There is one chapter each for the following techniques: angioplasty - intra-arterial fibrinolysis - vascular stents - neuroembolisation - embolisation of other vessels - biliary interventions - abscess drainage - nephrostomy and ureteral manipulations -percutaneous fine-needle biopsy - vena cava filters - interventional radiology in infants. (orig.)

  9. Streamlining interventional radiology admissions: The role of the interventional radiology clinic and physician's assistant

    International Nuclear Information System (INIS)

    White, R.I. Jr.; Rizer, D.M.; Shuman, K.; White, E.J.; Adams, P.; Doyle, K.; Kinnison, M.

    1987-01-01

    During a 5-year period (1982-1987), 376 patients were admitted to an interventional radiology service where they were managed by the senior physician and interventional radiology fellows. Sixty-eight percent of patients were admitted for angioplasty and 32% for elective embolotherapy/diagnostic angiography. A one-half-day, twice weekly interventional radiology clinic and employment of a physician's assistant who performed preadmission history and physicals and wrote orders accounted, in part, for a decrease in hospital stay length from 3.74 days (1982-1983) to 2.41 days (1986-1987). The authors conclude that use of the clinic and the physician's assistant streamlines patient flow and the admitting process and is partially responsible for a decreased length of stay for patients admitted to an interventional radiology service

  10. [Evaluation of patient doses in interventional radiology].

    Science.gov (United States)

    Ropolo, R; Rampado, O; Isoardi, P; Gandini, G; Rabbia, C; Righi, D

    2001-01-01

    To verify the suitability of indicative quantities to evaluate the risk related to patient exposure, in abdominal and vascular interventional radiology, by the study of correlations between dosimetric quantities and other indicators. We performed in vivo measurements of entrance skin dose (ESD) and dose area product (DAP) during 48 procedures to evaluate the correlation among dosimetric quantities, and an estimation of spatial distribution of exposure and effective dose (E). To measure DAP we used a transmission ionization chamber and to evaluate ESD and its spatial distribution we used radiographic film packed in a single envelope and placed near the patient's skin. E was estimated by a calculation software using data from film digitalisation. From the data derived for measurements in 27 interventional procedures on 48 patients we obtained a DAP to E conversion factor of 0.15 mSv / Gy cm2, with an excellent correlation (r=.99). We also found a good correlation between DAP and exposure parameters such as fluoroscopy time and number of images. The greatest effective dose was evaluated for a multiple procedure in the hepatic region, with a DAP value of 425 Gy cm2. The greatest ESD was about 550 mGy. For groups of patients undergoing similar interventional procedures the correlation between ESD and DAP had conversion factors from 6 to 12 mGy Gy-1 cm-2. The evaluation of ESD and E by slow films represents a valid method for patient dosimetry in interventional radiology. The good correlation between DAP and fluoroscopy time and number of images confirm the suitability of these indicators as basic dosimetric information. All the ESD values found are lower than threshold doses for deterministic effects.

  11. Diagnostic reference levels and complexity indices in interventional radiology: a national programme

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Cruces, R.; Perez-Martinez, M.; Pastor-Vega, J.M.; Canete, S. [University of Malaga, School of Medicine, Malaga (Spain); Vano, E.; Fernandez-Soto, J.M.; Sanchez-Casanueva, R.; Gallego-Beuter, J.J. [Complutense University, San Carlos Hospital, Medical School, Madrid (Spain); Carrera-Magarino, F.; Moreno-Rodriguez, F.; Moreno-Sanchez, T. [Juan Ramon Jimenez University Hospital, Huelva (Spain); Soler-Cantos, M.M.; Canis-Lopez, M. [Reina Sofia University Hospital, Cordoba (Spain); Hernandez-Armas, J.; Diaz-Romero, F.J. [University Hospital of Canary Islands, Tenerife (Spain); Rosales-Espizua, F.; Lopez-Medina, A.; Gonzalez-de-Garay, M. [Basurto Hospital, Bilbao (Spain); Martin-Palanca, A. [Virgen de la Victoria University Hospital, Malaga (Spain); Gil-Agudo, A.; Zarca-Diaz, M.A.; Zapata-Jimenez, J.C. [General University Hospital, Ciudad Real (Spain); Parra-Osorio, V.; Munoz Ruiz-Canela, J.J.; Moreno-Saiz, C.; Galan-Montenegro, P. [Carlos Haya University Hospital, Malaga (Spain)

    2016-12-15

    To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm{sup 2} for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. (orig.)

  12. Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 2: Patient Preparation and Medications)

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology (United States); Sebaaly, Mikhael Georges, E-mail: ms246@aub.edu.lb; Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [American University of Beirut Medical Center, Department of Diagnostic Radiology (Lebanon)

    2016-04-15

    Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care. Patient care before and after an interventional procedure, identification, and management of early and delayed complications of various procedures are equal in importance to the procedure itself. In this second part, we complete the comprehensive, methodical review of pre-procedural care and patient preparation before vascular and interventional radiology procedures.

  13. A mobile interventional radiology unit: innovation and social responsibility

    Directory of Open Access Journals (Sweden)

    Nestor Hugo Kisilevzky

    2010-03-01

    Full Text Available Objective: To present the preliminary results of a feasibility study performed to determine the value of a mobile interventional radiology unit used to promote a uterine embolization program for low-income patients. Methods: Forty patients with symptomatic fibroids were treated with uterine embolization. Procedures were performed in four public hospitals in the metropolitan area of Sao Paulo. This study was approved by the institutional research ethics committee and all patients signed an informed consent form. A mobile interventional radiology unit, named ANGIOMOVEL, was conceived and implemented utilizing a small truck to transport one mobile C arm, one radiological table, protection aprons and a small trolley containing specific supplies for the procedures. The ANGIOMOVEL team consisted of two interventional radiologists, one nurse, one driver and one assistant. The unit visited one hospital per week during a three-month period. Patient inclusion was contingent upon several factors, such as evaluation by a trained gynecologist, completion of a pelvic MRI, routine serological laboratory tests and completion of a quality of life questionnaire (QOL. Outcomes, MRI and QOL were evaluated. Data obtained after 12 weeks were collected and analyzed. Results: Technical success was achieved in 100% of cases, with a mean procedure time of 43 minutes and a mean fluoroscopic time of 24 minutes. The mean hospital stay was 1.07 day and the mean time for recovery and return to normal activities was 10 days. After 12 weeks, 36 (90% of patients noticed improvement of their symptoms and 4 (10% did not notice any improvement. Thirty-eight patients (95% were satisfied or very satisfied and 39 (97.5% said they would recommend the procedure. Pre- and post-procedure magnetic resonance imaging analysis showed that complete fibroid ischemia was achieved in 92.5% of cases with a mean uterine volume reduction of 38% and a mean fibroid volume reduction of 52%. Health

  14. Analgosedation and monitoring in interventional radiology

    International Nuclear Information System (INIS)

    Girolami, Guido; Steinbrich, Roman; Jacob, Augustinus Ludwig

    2010-01-01

    This article deals with the change of treatment in interventional radiology during the last decade adding a wider margin of safety through automated monitoring and better patient comfort through a combination of sedation and analgetics. In this regard it is very important to ensure adherence to standard procedures that are as simple as possible, to provide adequate training of staff members and to keep a succinct procedure protocol to ensure a high quality of care. Guidelines and checklists for the safe performance of this 'comfort-therapy' are given. (orig.)

  15. Intervention levels for protective action in the radiological emergency

    International Nuclear Information System (INIS)

    Lee, G.Y.; Khang, B.O.; Lee, M.; Lee, J.T.

    1998-09-01

    In the event of nuclear accident or radiological emergency, the protective action based on intervention levels prepared in advance should be implemented in order to minimize the public hazard. There are several protective measures such as sheltering, evacuation, iodine prophylaxis, foodstuff restrictions, temporary relocation, permanent resettlement, etc. for protecting the public. The protective measures should be implemented on the basis of operational intervention level of action level. This report describes the basic principles of intervention and the methodology for deriving intervention levels, and also recommendations for the intervention levels suggested from IAEA, ICRP, WHO and EU are summarized to apply to the domestic radiological emergency. This report also contains a revision procedure of operational intervention levels to meet a difference accident condition. Therefore, it can be usefully applied to establish revised operational intervention levels considering or the regional characteristics of our country. (author). 20 refs

  16. Safety and effectiveness of moderate sedation for radiologic non-vascular intervention

    International Nuclear Information System (INIS)

    Kim, Tae-Hoon

    2006-01-01

    The purpose of this study was to prospectively characterize the safety and effectiveness of moderate sedation/analgesia for performing radiologic non-vascular abdominal intervention. During a 3-month period, a total of 63 adult patients with a mean age of 64 years (range:27-82) underwent moderate sedation for 72 radiologic non-vascular interventional procedures. A combination of fentanyl citrate and midazolam hydrochloride, based on the patient's body weight, was intravenously administered until the patient was drowsy and tranquil. The adverse events associated with this moderate sedation were assessed. The visual analog scale format was used to measure the subjective feelings of the patient's pre-pro- cedural anxiety and intraprocedural pain. The mean total dose per kilogram of body weight of fentanyl used in PTBD was 1.148 μg. The mean total dose per kilogram of body weight of midazolam was 0.035 mg in PTBD, PTGBD, AD, PCN, DJS, GS and FRA, 0.039 mg in TDC, and 0.043 mg in BS. A temporary reduction of systolic blood pressure to less than 80 mmHg was observed during 5 procedures (6.9%), whereas a temporary elevation of systolic blood pressure above 150 mmHg was observed during 10 procedures (13.8%). A reduction of arterial oxygen saturation to less than 90% was observed during 14 procedures (19.4%). None of the patients required pharmacologic reversal agents or cardiopulmonary resuscitation. The mean anxiety score recorded before all procedures was 5.2 (distressing). The mean pain score during the procedure, which was recorded after all procedures, was 2.9 (mild). Moderate sedation allows performance of safe and effective radiologic non-vascular intervention, and it is also easy for an interventional radiologist to use. The patients should be continuously monitored to check their vital signs and arterial oxygen saturation during the procedures

  17. Safety and effectiveness of moderate sedation for radiologic non-vascular intervention

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hoon [Dankook University Hospital, Chungju (Korea, Republic of)

    2006-06-15

    The purpose of this study was to prospectively characterize the safety and effectiveness of moderate sedation/analgesia for performing radiologic non-vascular abdominal intervention. During a 3-month period, a total of 63 adult patients with a mean age of 64 years (range:27-82) underwent moderate sedation for 72 radiologic non-vascular interventional procedures. A combination of fentanyl citrate and midazolam hydrochloride, based on the patient's body weight, was intravenously administered until the patient was drowsy and tranquil. The adverse events associated with this moderate sedation were assessed. The visual analog scale format was used to measure the subjective feelings of the patient's pre-pro- cedural anxiety and intraprocedural pain. The mean total dose per kilogram of body weight of fentanyl used in PTBD was 1.148 {mu}g. The mean total dose per kilogram of body weight of midazolam was 0.035 mg in PTBD, PTGBD, AD, PCN, DJS, GS and FRA, 0.039 mg in TDC, and 0.043 mg in BS. A temporary reduction of systolic blood pressure to less than 80 mmHg was observed during 5 procedures (6.9%), whereas a temporary elevation of systolic blood pressure above 150 mmHg was observed during 10 procedures (13.8%). A reduction of arterial oxygen saturation to less than 90% was observed during 14 procedures (19.4%). None of the patients required pharmacologic reversal agents or cardiopulmonary resuscitation. The mean anxiety score recorded before all procedures was 5.2 (distressing). The mean pain score during the procedure, which was recorded after all procedures, was 2.9 (mild). Moderate sedation allows performance of safe and effective radiologic non-vascular intervention, and it is also easy for an interventional radiologist to use. The patients should be continuously monitored to check their vital signs and arterial oxygen saturation during the procedures.

  18. Guidelines for radiological interventions

    International Nuclear Information System (INIS)

    Kauffmann, G.W.

    1998-01-01

    The German Radiological Society, in cooperation with other German professional bodies, set up draft Guidelines for Radiological Interventions and submitted them to the professional community for discussion. The Guidelines are meant to assess the potential of radiological interventions as treatment alternatives to surgery or aggressive therapy such as chemotherapy. In fact, technical practicability on its own is insufficient to warrant intervention. The Guidelines are systematically compiled notions and recommendations whose aim it is to provide support to physicians and patients in choosing suitable medical care provisions (prevention, diagnosis, therapy, aftertreatment) in specific circumstances. A complete Czech translation of the Guidelines is given. (P.A.)

  19. Radiation load of the extremities and eye lenses of the staff during selected interventional radiology procedures

    International Nuclear Information System (INIS)

    Nikodemova, Denisa; Trosanova, Dominika

    2010-01-01

    The Slovak Medical University in Bratislava is involved in the ORAMED (Optimization of Radiation Protection for Medical Staff) research project, aimed at developing a unified methodology for a more accurate assessment of professional exposure of interventional radiology staff, with focus on extremity and eye lens dosimetry in selected procedures. Three cardiac procedures and 5 angiography examinations were selected: all technical parameters were monitored and the dose equivalent levels were measured by TL dosimetry at 9 anatomic sites of the body. Preliminary results were obtained for the radiation burden of the eyes and extremities during digital subtraction angiography of the lower limbs, collected from 7 hospital departments in partner EU states. Correlations between the evaluated data and the influence of some parameters are shown

  20. Generic procedures for assessment and response during a radiological emergency

    International Nuclear Information System (INIS)

    2000-08-01

    One of the most important aspects of managing a radiological emergency is the ability to promptly and adequately determine and take actions to protect members of the public and emergency workers. Radiological accident assessment must take account of all critical information available at any time and must be an iterative and dynamic process aimed at reviewing the response as more detailed and complete information becomes available. This manual provides the tools, generic procedures and data needed for an initial response to a non-reactor radiological accident. This manual is one out of a set of IAEA publications on emergency preparedness and response, including Method for the Development of Emergency Response Preparedness for Nuclear or Radiological Accidents (IAEA-TECDOC-953), Generic Assessment Procedures for Determining Protective Actions During a Reactor Accident (IAEA-TECDOC-955) and Intervention Criteria in a Nuclear or Radiation Emergency (Safety Series No. 109)

  1. Activity-based cost analysis in catheter-based angiography and interventional radiology

    International Nuclear Information System (INIS)

    Rautio, R.; Keski-Nisula, L.; Paakkala, T.

    2003-01-01

    The aim of this study was to analyse the costs of the interventional radiology unit and to identify the cost factors in the different activities of catheter-based angiographies and interventional radiology. In 1999 the number of procedures in the interventional radiological unit at Tampere University Hospital was 2968; 1601 of these were diagnostic angiographies, 526 endovascular and 841 nonvascular interventions. The costs were analysed by using Activity Based Cost (ABC) analysis. The budget of the interventional unit was approximately 1.8 million Euro. Material costs accounted for 67%, personnel costs for 17%, equipment costs for 14% and premises costs for 2% of this. The most expensive products were endografting of aortic aneurysms, with a mean price of 5291 Euro and embolizations of cerebral aneurysms (4472 Euro). Endografts formed 87.3% of the total costs in endografting and Guglielmi detachable coils accounted for 63.3% of the total costs in embolizations. The material costs formed the majority of the costs, especially in the newest and most complicated endovascular treatments. Despite the high cost of angiography equipment, its share of the costs is minor. In our experience ABC system is suitable for analysing costs in interventional radiology. (orig.)

  2. Optimization of Patient Doses in Interventional Radiology and Cardiology

    International Nuclear Information System (INIS)

    Nikodemova, D.; Boehm, K.

    2011-01-01

    Interventional radiology and cardiology belongs to the imaging modalities connected with significantly higher radiation exposure of patients and medical staff, compared to the exposure during other diagnostic procedures. The objective of this presentation is to promote typical technical parameters and parameters related to the radiation policy, used during the most frequent endovascular and cardiology procedures, as well as the monitoring of the exposure of patients. The presented study reports the results of collecting the data of monitoring doses received by 318 patients undergoing interventional examinations in 3 various departments of the Slovak National Institute of Cardiology and Vascular Diseases. There were 9 different endovascular and cardiology procedures reviewed. The reported patient's radiation exposures were established by using the KAP values, directly shown on the display of the X-ray equipment. From the measured KAP values the entrance surface doses were calculated. Equivalent doses have been measured on hands, legs and other parts of medical staff body, by using electronic dosimeters or thermoluminescent dosimeters. The presented results have covered a wide range of the measured fluoroscopy time values, different number of acquisitions used in various interventional procedures, various cumulated KAP values and also a wide range of the cumulated entrance surface doses. The occupational doses of the operators, followed during dose measurements on their left hands, covered the range from 0.1 μSv to 1513 μSv for one examination performed. The important contribution of the presented results to the radiation protection policy in the Slovak Republic is the mapping of the current situation of the radiation exposure of patients undergoing the chosen interventional examinations and the professional radiation exposure level of interventional operators, providing the most significant interventional procedures in the Slovak interventional hospitals. The

  3. Intercomparison of active personal dosemeters in interventional radiology

    International Nuclear Information System (INIS)

    Clairand, I.; Struelens, L.; Bordy, J. M.; Daures, J.; Debroas, J.; Denozieres, M.; Donadille, L.; Gouriou, J.; Itie, C.; Vaz, P.; D'Errico, F.

    2008-01-01

    The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its sixth Framework Programme. Interventional radiology procedures can be very complex and they can lead to relatively high doses to personnel who stand close to the primary radiation field and are mostly exposed to radiation scattered by the patient. For the adequate dosimetry of the scattered photons, APDs must be able to respond to low-energy [10-100 keV] and pulsed radiation with relatively high instantaneous dose rates. An intercomparison of five APD models deemed suitable for application in interventional radiology was organised in March 2007. The intercomparison used pulsed and continuous radiation beams, at CEA-LIST (Saclay (France)) and IRSN (Fontenay-aux-Roses (France)), respectively. A specific configuration, close to the clinical practice, was considered. The reference dose, in terms of Hp(10), was derived from air kerma measurements and from the measured and calculated energy distributions of the scattered radiation field. Additional Monte Carlo calculations were performed to investigate the energy spectra for different experimental conditions of the intercomparison. The results of this intercomparison are presented in this work and indicate which APDs are able to provide a correct response when used in the specific low-energy spectra and dose rates of pulsed X-rays encountered in interventional radiology. (authors)

  4. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  5. 2000 RSNA annual oration in diagnostic radiology: The future of interventional radiology.

    Science.gov (United States)

    Becker, G J

    2001-08-01

    Origins in imaging, procedural emphasis, and dependence on innovation characterize interventional radiology, which will continue as the field of image-guided minimally invasive therapies. A steady supply of innovators will be needed. Current workforce shortages demand that this problem be addressed and in an ongoing fashion. Interventional radiology's major identity problem will require multiple corrective measures, including a name change. Diagnostic radiologists must fully embrace the concept of the dedicated interventionalist. Interspecialty turf battles will continue, especially with cardiologists and vascular surgeons. To advance the discipline, interventional radiologists must remain involved in cutting-edge therapies such as endograft repair of aortic aneurysms and carotid stent placement. As the population ages, interventionalists will experience a shift toward a greater emphasis on cancer treatment. Political agendas and public pressure will improve access to care and result in managed health care reforms. Academic centers will continue to witness a decline in time and resources available to pursue academic missions. The public outcry for accountability will result in systems changes aimed at reducing errors and process changes in the way physicians are trained, certified, and monitored. Evidence-based medicine will be the watchword of this century. Interventional radiology will maintain its role through development of methods for delivery of genes, gene products, and drugs to specific target sites; control of angiogenesis and other biologic processes; and noninvasive image-guided delivery of various forms of energy for ablation.

  6. Radiological findings and interventions for iatrogenic vascular injuries

    International Nuclear Information System (INIS)

    Lee, Kyoung Ho; Chung, Jin Wook; Kim, Tae Kyoung; Han, Sang Wook; Lee, Jong Seog; Park, Jae Hyung; Kim, Jong Hyo; Han, Man Chung

    1998-01-01

    The purpose of this study is to evaluate the radiological findings and effectiveness of radiological interventions in patients with iatrogenic vascular injuries. We analyzed 50 patients with iatrogenic vascular injuries treated with radiological intervention. The causes of injuries were surgery (n=20), cardiovascular intervention (n=15), non-cardiovascular radiological intervention (n=14), and endoscopic intervention (n=1). The injury had resulted in hemorrhage in 35 cases. The iliac and/or femoral, hepatic, and renal vessels were commonly injured. Angiography, ultrasonography with Doppler examination, CT, and CT angiography were performed to diagnose vascular injuries and guide the radiological intervention. The mean follow-up period was 23 months and in 16 cases was more than one year. the major radiological findings were extravasation, pseudoaneurysm, arteriovenous shunt, or vascular obstruction. To control these lesions, radiological interventions such as embolization (n=36), local urokinase administration, stent insertion, foreign body removal, ultrasonography-guided compression, or stent-graft insertion were performed. The clinical problems were immediately controlled by the single trials of radiological interventions and did not recur in 40 cases (80%). Radiological examinations and interventions are useful in cases with iatrogenic vascular injuries. (author). 14 refs., 4 figs

  7. Is hair loss a reality in neuro-interventional radiology?

    LENUS (Irish Health Repository)

    Gavagan, L

    2012-02-01

    Reports in the literature of radiation-induced hair loss are becoming increasingly common. This work describes a retrospective dose study of patients (n = 958) undergoing diagnostic (primarily cerebral angiograms) and therapeutic (primarily cerebral embolisation) procedures in a neuro-interventional suite. A comparison of patient doses as dose area product (DAP) readings from a single-plane image intensifier system (mean DAP value of 8772 cGy cm(2)) were compared with patient doses from a flat panel biplane system (mean DAP value of 7855 cGy cm(2)). Over 80 % of patients requiring neuro-interventional procedures were found to undergo two procedures or more. An estimated 7 % of therapeutic procedures were found to reach the International Commission on Radiological Protection threshold for temporary epilation.

  8. Value of levels of complexity in the estimation of the risk in interventional radiology procedures; Valor de los indices de complejidad en la estimacion del riesgo en procedimientos de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Cruces, R.; Vano, E.; Hernandez Armas, J.; Carrera Magarino, F.; Rosales, F.; Galan, P.; Solar, M. M.; Perez Martinez, M.; Sanchez Casanueva, R.; Moreno Saiz, C.; Caudepon, F.; Diaz, F.; Gallego Solar, J. J.; Martin-Palanca, A.; Ruiz Munoz-Canela, J. J.; Moreno Rodriguez, F.; Gonzalez de Garay, M.; Canis, M.; Lopez Medina, A.; Moreno Sachez, T.; Pastor Vega, J. M.

    2013-07-01

    The interventional Radiology (IR) refers to guided procedures with X rays, to develop a diagnostic and/or therapeutic action both in vascular diseases as non-vascular. The progressive increase in the complexity and diversity of interventional procedures make it difficult to objectify the criteria about the dosage provided to patients who are these techniques. Control of radiation doses administered to patients to limit the risks associated with the use of x-rays is not more than one way of improving procedures. For this reason, already completed the ERRAPRI project, we have developed complexity rates to better assess the radiological risk associated with the procedures carried out in a sample of Spanish hospitals. (Author)

  9. Radiological management of patients with urinary obstruction following urinary diversion procedures: technical factors, complications, long-term management and outcome. Experience with 378 procedures.

    LENUS (Irish Health Repository)

    Maher, M M

    2012-02-03

    We aimed to assess management by interventional radiology techniques of patients with urinary diversion procedures (UD) complicated by urinary obstruction (UO). A 12-year electronic database of interventional cases was searched for urinary access in patients with UD. Patients\\' records were assessed for aetiology of obstruction, indication for procedure, types of interventional radiology, complications and outcome. Management issues included frequency of visits for catheter care, type of catheter placement and technical problems associated with catheter maintenance. Three hundred and seventy eight procedures were carried out in 25 patients (mean age 70 years; Male : Female ratio 13:12). Indications for UD were malignancy (n = 22) and neuropathic bladder (n = 3). UD included ileal conduits (n = 17), cutaneous ureterostomy (n = 3 (2 patients)) and sigmoid colon urinary conduit (n = 6). In most patients, catheters were placed antegradely through nephrostomy tract, but subsequent access was through the UD. Twenty of 25 patients had unilateral stents where as 5 had bilateral stents (8-10- Fr pigtail catheters (20-45 cm in length)). The mean number of procedures including catheter changes was 15 +\\/- 4 per patient and 331 of 378 procedures (87 %) were carried out as outpatients. Since catheter placement, 11 patients required hospital admission on 22 occasions for catheter-related complications. Ureteric strictures in patients with UD can be successfully managed by interventional radiology.

  10. Comparison of patient doses in interventional radiology procedures performed in two large hospitals in Greece

    International Nuclear Information System (INIS)

    Papageorgiou, E.; Tsapaki, V.; Tsalafoutas, I. A.; Maurikou, E.; Kottou, S.; Orfanos, A.; Karidas, G.; Fidanis, T.; Zafiriadou, E.; Neofotistou, V.

    2007-01-01

    Purpose of the study was to determine patient doses in the most common interventional radiology (IR) procedures performed in two large Greek hospitals. A total of 164 patients who underwent 4 types of IR procedures were studied. Fluoroscopy time, total exposure time, number of frames, number of runs, radiation field size, and cumulative dose-area product (DAP) were recorded. The median DAP values for carotid arteriography and lower limb arteriography were 66 and 123 Gy cm 2 for hospital 'A' and 21 and 49 Gy cm 2 for hospital 'B'. For the cerebral arteriographies performed in hospital 'A', the median DAP was 116 Gy cm 2 while for the hepatic embolizations performed in hospital 'B', it was 104 Gy cm 2 . The DAP values observed in hospital 'A' for carotid arteriography and lower limb arteriography were almost three times than those of hospital 'B'. From the data analysis, it is evident that dose optimization in hospital 'A' should be pursued through revision of the techniques used. (authors)

  11. Patterns, incidence and predictive factors for pain after interventional radiology

    International Nuclear Information System (INIS)

    England, A.; Tam, C.L.; Thacker, D.E.; Walker, A.L.; Parkinson, A.S.; DeMello, W.; Bradley, A.J.; Tuck, J.S.; Laasch, H.-U.; Butterfield, J.S.; Ashleigh, R.J.; England, R.E.; Martin, D.F.

    2005-01-01

    AIM: To evaluate prospectively the pattern, severity and predictive factors of pain after interventional radiological procedures. MATERIALS AND METHODS: All patients undergoing non-arterial radiological interventional procedures were assessed using a visual-analogue scale (VAS) for pain before and at regular intervals for 24 h after their procedure. RESULTS: One hundred and fifty patients (87 men, mean age 62 years, range 18-92 years) were entered into the study. Significant increases in VAS score occurred 8 h after percutaneous biliary procedures (+47.7 mm, SD 14.9 mm; p=0.001), 6 h after central venous access and gastrostomy insertion (+23.7 mm, SD 19.5 mm; p=0.001 and +28.4 mm, SD 9.7 mm; p=0.007, respectively) and 4 h after oesophageal stenting (+27.8 mm, SD 20.2 mm, p=0.001). Non-significant increases in VAS pain score were observed after duodenal and colonic stenting (duodenal: +5.13 mm, SD 7.47 mm; p=0.055, colonic: +23.3 mm, SD 13.10 mm, p=0.250) at a mean of 5 h (range 4-6 h). Patients reported a significant reduction in pain score for nephrostomy insertion (-28.4 mm, SD 7.11 mm, p=0.001). Post-procedural analgesia was required in 99 patients (69.2%), 40 (28.0%) requiring opiates. Maximum post-procedural VAS pain score was significantly higher in patients who had no pre-procedural analgesia (p=0.003). CONCLUSION: Post-procedural pain is common and the pattern and severity of pain between procedures is variable. Pain control after interventional procedures is often inadequate, and improvements in pain management are required

  12. Performance of interventional procedures in a day-hospital system

    International Nuclear Information System (INIS)

    Bae, Jae Ik; Park, Auh Whan; Cho, Hye Seon; Park, Eun Hee; Choi, Gap Suk; Lee, Seon Ju; Kim, Yong Woo; Juhn, Je Ryang

    2007-01-01

    We wanted to describe the practice and results of applying the day-hospital system in an interventional radiology clinic. From Oct. 2004 to Dec. 2005, the day-hospital system was applied to various interventional procedures with using a part of the recovery room of an angiography suite as a facility for hospital admission. The study included 91 cases in 73 patients. The source of the patient referral, the procedures, hospital courses and complications were analyzed and questionnaire surveys were conducted for the available 55 patients. Among the patients, 70% (n=64) were referred form other departments, 5% (n=5) from other hospitals, 5% (n=4) were new patients and 20% (n=18) were re-admissions. The procedures included gastrointestinal, biliary, urinary, hemodialysis related-and implantable port related interventions. 96% (n=87) of the patients were successfully discharged in a day and admission to the general ward was only 4% (n=4). Minor complications occurred after discharges in 3% (n=3). The questionnaire survey revealed that 96% (n=53) of the patients were satisfied with the service and they were not anxious after discharge. Most of common interventional procedures were safely done under the day-hospital system with the patients being highly satisfied. The day-hospital system can be a good tool for establishing admitting privileges for an interventional radiology clinic

  13. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  14. Manual of extravascular minimally invasive interventional procedures of the liver and biliary tract

    International Nuclear Information System (INIS)

    Miranda Mena, Shirley

    2011-01-01

    The use of interventional radiology and image-guided surgery has increased. Interventional radiologists are involved in patient treatment, well as in the diagnosis of the disease carrying his knowledge to the tumor treatment and procedures more invasive. Large amount of didactic material there are available, but the country lacks a manual to standardize interventional radiological techniques carried out. Also, those that could be instituted and adapted effectively in the management of hepatobiliary pathology of the Sistema de Salud Publica in Costa Rica, that covers the main procedures and adopt guidelines in a standardized way. A manual of procedures minimally invasive radiologic extravascular of the liver and biliary tract, is presented with broad bibliographic support that directs, standardizes and is adaptable to the needs and own resources of Costa Rica. Interventional radiology has been a non surgical alternative of a low index of complications, useful for the management of some health problems, avoids surgery and certainly lower costs. An alternative to surgical treatment of many conditions is offered, thereby reducing complications (morbidity) and can eliminate the need for hospitalization, in some cases. The development of new materials has allowed the most common working tools of the medical field are improved and become increasingly more efficient in the diagnosis and treatment of diseases, improving the training of radiologists in the interventional field. (author) [es

  15. Study of radiation exposure profiles in interventional radiology professionals; Estudo dos perfis de exposicao a radiacao em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Bacchim Neto, Fernando A.; Alves, Allan F.F.; Alvarez, Matheus; Rosa, Maria E.D.; Miranda, Jose R.A.; Freitas, Carlos C.M. de; Moura, Regina; Pina, Diana R. de, E-mail: fernando.bacchim@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2014-07-01

    Interventional Radiology is the radiology area that provides the highest dose values to the medical staff. Recent surveys show that personal dosimeters may underestimate the radiation dose values in interventional physicians, especially in the extremities and crystalline. The objective of this work was to study the exposure levels to radiation from medical staff in different interventional radiology procedures. Therefore, thermoluminescent dosimeters type LiF: Mg, Ti (TLD-100) were used positioned in the main interventional physician and an assistant in the following locations: some inches below the crystalline, thyroid, chest, gonads, hand and foot. By comparing the values obtained with the annual reference dose levels in workers, maximum numbers of annual procedures were found. Altogether, there were 23 procedures evaluated: 10 diagnostics, 9 angioplasties and 4 stents. The maximum number of annual procedures were estimated by discounting the percentages of attenuation of radiological protection. For procedures of the type diagnosis, angioplasty and stent for the main interventionist, the maximum number of annual procedures were 641, 445 and 113 respectively, while for the interventionists assistants were 930, 1202 and 215 respectively. As each interventionist body region is subject to different levels of exposure, detailed studies of exposure in each region provide better conclusions about what actions are necessary to ensure radiological protection professionals.

  16. Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 1: Patient Assessment and Laboratory Tests)

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [NYU Langone Medical Center, Department of Radiology (United States); Sebaaly, Mikhael Georges, E-mail: ms246@aub.edu.lb; Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [American University of Beirut Medical Center, Department of Diagnostic Radiology (Lebanon)

    2016-03-15

    Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care after the procedure is completed. After patient referral, contact with the referring physician and multidisciplinary team approach is vital. In addition, clinical history, physical examination, as well as full understanding of the pre-procedural laboratory results and imaging findings can guide the interventional radiologist to implement the most appropriate management plan, avoid unnecessary procedures, and prevent complications to achieve a successful outcome. We provide a comprehensive, methodical review of pre-procedural care and management in patients undergoing vascular and interventional radiology procedures.

  17. Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 1: Patient Assessment and Laboratory Tests)

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Sebaaly, Mikhael Georges; Al-Kutoubi, Aghiad

    2016-01-01

    Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care after the procedure is completed. After patient referral, contact with the referring physician and multidisciplinary team approach is vital. In addition, clinical history, physical examination, as well as full understanding of the pre-procedural laboratory results and imaging findings can guide the interventional radiologist to implement the most appropriate management plan, avoid unnecessary procedures, and prevent complications to achieve a successful outcome. We provide a comprehensive, methodical review of pre-procedural care and management in patients undergoing vascular and interventional radiology procedures

  18. The Importance of Curriculum-Based Training and Assessment in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Belli, Anna-Maria, E-mail: anna.belli@stgeorges.nhs.uk [St. George’s Hospital, Department of Radiology (United Kingdom); Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl [Academic Medical Centre, Department of Radiology (Netherlands); Lee, Michael, E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2013-10-30

    Physician performance and outcomes are being scrutinised by health care providers to improve patient safety and cost efficiency. Patients are best served by physicians who have undergone appropriate specialist training and assessment and perform large numbers of cases to maintain their skills. The Cardiovascular and Interventional Radiological Society of Europe has put into place a curriculum for training in interventional radiology (IR) and a syllabus with an examination, the European Board of Interventional Radiology, providing evidence of attainment of an appropriate and satisfactory skill set for the safe practice of IR. This curriculum is appropriate for IR where there is a high volume of image-guided procedures in vascular and nonvascular organ systems with cross-use of minimally invasive techniques in patients with a variety of disease processes. Other specialties may require different, longer, and more focused training if their experience is “diluted” by the need to master a different skill set.

  19. The Importance of Curriculum-Based Training and Assessment in Interventional Radiology

    International Nuclear Information System (INIS)

    Belli, Anna-Maria; Reekers, Jim A.; Lee, Michael

    2014-01-01

    Physician performance and outcomes are being scrutinised by health care providers to improve patient safety and cost efficiency. Patients are best served by physicians who have undergone appropriate specialist training and assessment and perform large numbers of cases to maintain their skills. The Cardiovascular and Interventional Radiological Society of Europe has put into place a curriculum for training in interventional radiology (IR) and a syllabus with an examination, the European Board of Interventional Radiology, providing evidence of attainment of an appropriate and satisfactory skill set for the safe practice of IR. This curriculum is appropriate for IR where there is a high volume of image-guided procedures in vascular and nonvascular organ systems with cross-use of minimally invasive techniques in patients with a variety of disease processes. Other specialties may require different, longer, and more focused training if their experience is “diluted” by the need to master a different skill set

  20. Exposure of Medical Staff during Interventional Procedures

    International Nuclear Information System (INIS)

    Osvay, M.; Turak, O.

    2013-01-01

    The medical staff during interventional procedures receives significant doses on their hands, or parts of their body not covered with protective shielding equipment, as they are close to X-rays field. It can be stated, that interventional radiology and cardiology have one of the highest doses among the X-ray diagnostic procedures. The radiologist use X-ray machine directly in the interventional procedures. The occupational dose is measured only by one Kodak film badge worn under the lead apron for the estimation of the effective dose in Hungary. Our lecture presents the results of dose measurements on eye lens, hands, knees using LiF thermoluminescent dosemeters on the medical staff of two Hungarian hospitals. Results suggest that wearing only one film badge (or other dosemeter system) under the lead apron does not provide proper information on the real occupational dose of medical staff.(author)

  1. Post-procedural Care in Interventional Radiology: What Every Interventional Radiologist Should Know—Part I: Standard Post-procedural Instructions and Follow-Up Care

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: Bedros.Taslakian@nyumc.org; Sridhar, Divya [NYU Langone Medical Center, Department of Radiology, Interventional Radiology Section (United States)

    2017-04-15

    Interventional radiology (IR) has evolved into a full-fledged clinical specialty with attendant patient care responsibilities. Success in IR now requires development of a full clinical practice, including consultations, inpatient admitting privileges, and an outpatient clinic. In addition to technical excellence and innovation, maintaining a comprehensive practice is imperative for interventional radiologists to compete successfully for patients and referral bases. A structured approach to periprocedural care, including routine follow-up and early identification and management of complications, facilitates efficient and thorough management with an emphasis on quality and patient safety.

  2. Patient Safety in Interventional Radiology: A CIRSE IR Checklist.

    LENUS (Irish Health Repository)

    2012-02-01

    Interventional radiology (IR) is an invasive speciality with the potential for complications as with other invasive specialities. The World Health Organization (WHO) produced a surgical safety checklist to decrease the morbidity and mortality associated with surgery. The Cardiovascular and Interventional Society of Europe (CIRSE) set up a task force to produce a checklist for IR. Use of the checklist will, we hope, reduce the incidence of complications after IR procedures. It has been modified from the WHO surgical safety checklist and the RAD PASS from Holland.

  3. Occupational exposure for workers in interventional radiological examination

    International Nuclear Information System (INIS)

    Suliman, E.E.

    2005-01-01

    Full text: An interventional radiological examination is a diagnostic or therapeutic in any organ or anatomical region using images acquired with ionizing radiation. Compared to other radiological acquisition, personnel who perform interventional procedures, which involve long fluoroscopy times and a high workload may receive radiation doses comparable to the dose limits. Therefore to ensure that no person be subjected to an unacceptable risk from radiation, that need for accurate individual monitoring has arisen. In this work, the doses received by physician in cardiac angiography were evaluated and the results of two months were presented. Only 7 physicians were monitored. Hence the data available is presented, and it is hoped to provide some information on the assessment of occupational exposure in interventional radiological examination. Measurements were done using Thermoluminescence dosimeters (TLD) and a calibrated Harshaw Reader. Two TLDs were used by each physician, one worn under a protective apron at the waist (H W ) and the other worn outside and above the apron at the neck (H N ). The effective dose E was estimated from the formula: E (estimated) = 0.5 H W + 0.025 H N . From the result obtained it was concluded that, the weak point of radiation protection philosophy in medical application is in the work of interventional physicians who have no full time decision like the radiologist physicians and therefore haven't enough knowledge about the radiation and radiation protection. So they are the highest risk group among physicians and to whom the efforts must be directed. (author)

  4. What Does Competence Entail in Interventional Radiology?

    International Nuclear Information System (INIS)

    Ahmed, Kamran; Keeling, Aoife N.; Khan, Reenam S.; Ashrafian, Hutan; Arora, Sonal; Nagpal, Kamal; Burrill, Joshua; Darzi, Ara; Athanasiou, Thanos; Hamady, Mohamad

    2010-01-01

    Interventional radiology is a relatively new speciality and may be referred to as 'image-guided surgery without a scalpel.' Training and accreditation bodies regard interventional radiology training as being 'different' from general radiology because of the additional need for dexterity and clinical acumen. Due to the multidimensional role of an interventional radiologist, a practitioner in this discipline must have a number of the competencies of anesthetists, surgeons, and radiologists. The attributes required of an interventional radiologist are akin to those required of a surgeon. This paper gives an overview of the skills required to be a competent interventional radiologist along with a succinct introduction to methods of assessment of technical and non-technical skills.

  5. Occupational radiation doses during interventional procedures

    International Nuclear Information System (INIS)

    Nuraeni, N; Hiswara, E; Kartikasari, D; Waris, A; Haryanto, F

    2016-01-01

    Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits. (paper)

  6. Characterization of workplaces in interventional radiology using active dosemeters ALARA OD

    International Nuclear Information System (INIS)

    Prlic, I.; Milkovic-Kraus, S.; Mestrovic, T.; Suric-Mihic, M.; Vrtar, M.

    2005-01-01

    Full text: Because of progressive development and extended use of interventional radiology procedures it is highly recommended that all individuals involved in the process should be aware of the potential for both stochastic and deterministic effects due to occupational exposure. Interventional radiology procedures are essentially therapeutic and are performed by various medical specialists, not only by properly educated radiologists. As the procedures are performed in such a manner that certain number of medical staff are always needed near the patient, near the x- ray unit, ensuring 'safe' working environment in such radiation x-ray field geometry is a new challenge to regular radiation protection. In this work we are not primary concerned in relatively high doses delivered to patients undergoing interventional procedures. The patient is rather regarded as a secondary radiation source which emits scattered x-rays. The working staff, moving in mixed, primary and scattered x-ray field, is expected to be exposed to higher occupational doses due to combination of extended fluoroscopy times, elevated fluoroscopy currents and larger amount of radiographic images required. The protection of both patients and staff is to be upgraded. As passive dosemetes will give us clear knowledge only about the monthly integrated occupational dose, a reasonable doubt exists about the frequency and duration, of receiving the dose. Measuring dose rate is not a part of regular passive dosemeters monitoring systems. This is why we have developed active - electronic dosemeter device which provides us with additional dosimetry data about the frequency and duration of professional exposure burden. Digital dosemeter ALARA OD will record and integrate any occupational dose including the normal radiation background in the working area. It will record the time and duration of any fluoroscopic exposure done. This gives us the data about the dose rate of occupational radiation and frequency of

  7. Slovenian experience from diagnostic angiography to interventional radiology

    International Nuclear Information System (INIS)

    Pavcnik, Dusan

    2014-01-01

    The purpose of writing this article is to document the important events and people in the first 50 years of diagnostic angiography and interventional radiology in Slovenia. During this period not only did the name of the institutions and departments change, but also its governance. This depicted the important roles different people played at various times in the cardiovascular divisions inside and outside of the diagnostic and interventional radiology. Historical data show that Slovenian radiology has relatively immediately introduced the new methods of interventional radiology in clinical practice

  8. Patient dose assessment in various Interventional radiology and cardiology procedures in Algeria (IAEA regional project results)

    International Nuclear Information System (INIS)

    Khelassi-Toutaoui, Nadia; Merad, Ahmed; Toutaoui, A.E.K.; Bairi, Souad

    2008-01-01

    Full text: Purpose: To evaluate patient doses in Interventional Radiology (IR) and Cardiology (IC) procedures in Algeria, within the framework of an International Atomic Energy Agency (IAEA) regional project on radiation protection of patients and medical exposure control (RAF 9033). Materials and Methods: Three public hospitals (CHU Bab el Oued, CHU Parnet and CHU Mustapha) and one specialised Cardiology Service (Clinique Maouche) were chosen for the study. For Maximum Skin Dose (MSD) evaluation, gafchromic films XR type R were used, placed on patient's back before the procedure. The Dose Area Product (DAP) and MSD were measured in 57 IR and IC procedures, either diagnostic or therapeutic. Results: The results revealed large variations in MSD (0.06-3.3 Gy) and DAP (5.5-332 mGycm 2 ). Mean MSD was 0.227 Gy in cerebral angiography, 0.202 Gy in coronary angiography, 1.162 Gy in Percutaneus Transluminal Coronary Angioplasty (PTCA) and 0.128 in abdominal angiography. The correlation of DAP and MSD was significant (r = 0.7). The correlation was DAP and fluoroscopy time was also significant (r = 0.8). Conclusion: The highest MSD values were found in PTCA which is a therapeutic procedure. Two PTCAs out of the 57 procedures measured in total had MSD over the threshold of 2 Gy for deterministic effects (MSD 1 = 3.0 Gy and MSD 2 3.3 Gy). The large variations in MSD reveal the need to continuously monitor patient doses in IR and IC procedures with special emphasis in PTCA procedure. (author)

  9. Staff lens doses in interventional urology. A comparison with interventional radiology, cardiology and vascular surgery values

    International Nuclear Information System (INIS)

    Vano, E; Fernandez, J M; Sanchez, R M; Resel, L E; Moreno, J

    2016-01-01

    The purpose of this work is to evaluate radiation doses to the lens of urologists during interventional procedures and to compare them with values measured during interventional radiology, cardiology and vascular surgery. The measurements were carried out in a surgical theatre using a mobile C-arm system and electronic occupational dosimeters (worn over the lead apron). Patient and staff dose measurements were collected in a sample of 34 urology interventions (nephrolithotomies). The same dosimetry system was used in other medical specialties for comparison purposes. Median and 3rd quartile values for urology procedures were: patient doses 30 and 40 Gy cm 2 ; personal dose equivalent Hp(10) over the apron (μSv/procedure): 393 and 848 (for urologists); 21 and 39 (for nurses). Median values of over apron dose per procedure for urologists resulted 18.7 times higher than those measured for radiologists and cardiologists working with proper protection (using ceiling suspended screens) in catheterisation laboratories, and 4.2 times higher than the values measured for vascular surgeons at the same hospital. Comparison with passive dosimeters worn near the eyes suggests that dosimeters worn over the apron could be a reasonable conservative estimate for ocular doses for interventional urology. Authors recommend that at least the main surgeon uses protective eyewear during interventional urology procedures. (paper)

  10. Upgrade the intervention levels derived for water and foods, to be include in the PERE 607 procedure the external radiological emergency plan in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Llado Castillo, R.; Aguilar Pacheco, R.

    1998-01-01

    The work shows the results obtained in the upgrade the intervention levels derived for water and foods, to be include in the PERE 607 procedure the external radiological emergency plan in the Laguna Verde nuclear power plant

  11. Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?

    International Nuclear Information System (INIS)

    Chida, K.; Saito, H.; Ishibashi, T.; Zuguchi, M.; Kagaya, Y.; Takahashi, S.

    2009-01-01

    Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures

  12. Interventional radiology in congenital and acquired cardiovascular diseases

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.

    2000-01-01

    Interventional cardiology is a part of interventional radiology applying in urology, neurology, gynecology and other branches of medicine. The present-day achievements in interventional radiology in cardiovascular diseases: balloon valvuloplasty in cardiac diseases (isolated pulmonary arterial stenosis, aortic and mitral stenosis), balloon vasodilatation (peripheral pulmonary arterial stenosis, aortic coarctation), embolization of the vessels and pathological communications, atrioseptostomy, transcatheter closure of atrial septal defects are presented. It is shown that the achievements in interventional radiology in cardiovascular diseases are intimately associated with the progress in cannulation of heart and angiography [ru

  13. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins; Qualifizierungsleitlinie der Deutschen Roentgengesellschaft (DRG) und der Deutschen Gesellschaft fuer Interventionelle Radiologie und minimalinvasive Therapie (DeGIR) zur Durchfuehrung interventionell-radiologischer minimalinvasiver Verfahren an Arterien und Venen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A. [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany); Gross-Fengels, W. [Asklepiosklinik, Hamburg-Harburg (Germany); Haage, P. [Helios-Kliniken, Wuppertal (Germany); Huppert, P. [Klinikum Darmstadt (Germany); Landwehr, P. [Henriettenstiftung, Hannover (Germany); Loose, R. [Klinikum Nuernberg-Nord (Germany); Reimer, P. [Klinikum Karlsruhe (Germany); Tacke, J. [Klinikum Passau (Germany); Vorwerk, D. [Klinikum Ingolstadt (Germany); Fischer, J.

    2012-06-15

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  14. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  15. Status of radiation protection in interventional radiology. Assessment of inspections in 2009 by the ASN

    International Nuclear Information System (INIS)

    2011-01-01

    This report first describes the organization of inspections performed in health institutions, indicates the inspected establishments, the types of fixed installations in interventional radiology, the use of imagery in the operating theatre, and discusses the regulatory arrangements applicable to interventional radiology (in the Public Health Code, in the Labour Code). Then, the report discusses the results of inspections regarding radiation protection in interventional radiology: application of public health code arrangements (justification, patient training in radiation protection, radiological procedures and protocols, patient dosimetry monitoring), application of Labour Code arrangements (designation of the person with expertise in radiation protection, risk assessment and delimitation of monitored and controlled areas, workstation analysis, workers' training in radiation protection, individual protection equipment, workers' dosimetric monitoring, workers' medical monitoring, radiation protection technical controls), significant events, radiation protection in operating theatre. Propositions are stated regarding the differences noticed within or between the health establishments, the methodological and organisational difficulties faced by persons with expertise in radiation protection (PCR), the need of an interdisciplinary team

  16. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  17. Society of Interventional Radiology

    Science.gov (United States)

    ... Picture yourself in L.A. Register now SIR Essentials Purchase/register Search SIR's entire catalog for educational ... Quality Improvement Clinical practice MACRA Matters Health Policy, Economics, Coding Toolkits Society of Interventional Radiology 3975 Fair ...

  18. Guidelines on the facilities required for minor surgical procedures and minimal access interventions.

    LENUS (Irish Health Repository)

    Humphreys, H

    2012-02-01

    There have been many changes in healthcare provision in recent years, including the delivery of some surgical services in primary care or in day surgery centres, which were previously provided by acute hospitals. Developments in the fields of interventional radiology and cardiology have further expanded the range and complexity of procedures undertaken in these settings. In the face of these changes there is a need to define from an infection prevention and control perspective the basic physical requirements for facilities in which such surgical procedures may be carried out. Under the auspices of the Healthcare Infection Society, we have developed the following recommendations for those designing new facilities or upgrading existing facilities. These draw upon best practice, available evidence, other guidelines where appropriate, and expert consensus to provide sensible and feasible advice. An attempt is also made to define minimal access interventions and minor surgical procedures. For minimal access interventions, including interventional radiology, new facilities should be mechanically ventilated to achieve 15 air changes per hour but natural ventilation is satisfactory for minor procedures. All procedures should involve a checklist and operators should be appropriately trained. There is also a need for prospective surveillance to accurately determine the post-procedure infection rate. Finally, there is a requirement for appropriate applied research to develop the evidence base required to support subsequent iterations of this guidance.

  19. A model to determine payments associated with radiology procedures.

    Science.gov (United States)

    Mabotuwana, Thusitha; Hall, Christopher S; Thomas, Shiby; Wald, Christoph

    2017-12-01

    Across the United States, there is a growing number of patients in Accountable Care Organizations and under risk contracts with commercial insurance. This is due to proliferation of new value-based payment models and care delivery reform efforts. In this context, the business model of radiology within a hospital or health system context is shifting from a primary profit-center to a cost-center with a goal of cost savings. Radiology departments need to increasingly understand how the transactional nature of the business relates to financial rewards. The main challenge with current reporting systems is that the information is presented only at an aggregated level, and often not broken down further, for instance, by type of exam. As such, the primary objective of this research is to provide better visibility into payments associated with individual radiology procedures in order to better calibrate expense/capital structure of the imaging enterprise to the actual revenue or value-add to the organization it belongs to. We propose a methodology that can be used to determine technical payments at a procedure level. We use a proportion based model to allocate payments to individual radiology procedures based on total charges (which also includes non-radiology related charges). Using a production dataset containing 424,250 radiology exams we calculated the overall average technical charge for Radiology to be $873.08 per procedure and the corresponding average payment to be $326.43 (range: $48.27 for XR and $2750.11 for PET/CT) resulting in an average payment percentage of 37.39% across all exams. We describe how charges associated with a procedure can be used to approximate technical payments at a more granular level with a focus on Radiology. The methodology is generalizable to approximate payment for other services as well. Understanding payments associated with each procedure can be useful during strategic practice planning. Charge-to-total charge ratio can be used to

  20. Radiological protection in the interventional techniques: experience in the Pain Clinic of the CIMEQ

    International Nuclear Information System (INIS)

    Guerrero C, M. C.; Benitez N, P. P.; Gonzalez G, Y.; Martinez G, A.; Gonzalez R, N.; Sanchez Z, L. R.

    2014-08-01

    The Pain Clinic of the CIMEQ offers treatment to patients with different pathologies, using interventional techniques as the radiology like visual guide to reach the target structure and to apply the election technique. The personnel that carry out these procedures are inserted in the program of radiological surveillance of the institution, reason for which a radiological event could be detected where the main physician responsible of the service was implied. In this work the results of an investigation are presented realized with the objective of to know the causes of the event and to determine the necessary measures to avoid that this repeats again. The investigation was oriented to three fundamental aspects: medical exam of the affected worker; evaluation of the operational procedures from the radiological protection view point; and dosimetric measurements simulating the real conditions of work for which were used ionization chamber, radiometer and PMMA mannequin. As a result of the medical exam was detected that the main physician of the service did not use during the execution of all the procedures the extremities dosimetry and that he presented a radio induced erythema in the right hand, reason for which he was separated of the activity with ionizing radiations, until the conclusion of the investigation. With relationship to the evaluation of the operational procedures from the radiological protection view point, was verified that the medical physician not carried out any collimation of the beam and he was located in the positions where the dose rate reached the maximum values, frequently introducing the hands in the direct beam; that which implied an overexposure of the superior extremities and a not optimized exposure for whole body. This result was proven with the realized experimental measurements, which gave dose estimated values in extremities of the order of the deterministic effects. The investigation facilitated to introduce modifications in the

  1. Radiological Work Planning and Procedures

    CERN Document Server

    Kurtz, J E

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In add...

  2. Current Trends in Heparin Use During Arterial Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Durran, Alexandra C.; Watts, Christopher

    2012-01-01

    Purpose: This study was designed to assess the current use of heparinized saline and bolus doses of heparin in non-neurological interventional radiology and to determine whether consensus could be reached to produce guidance for heparin use during arterial vascular intervention. Methods: An interactive electronic questionnaire was distributed to members of the British Society of Interventional Radiology regarding their current practice in the use, dosage, and timing of heparin boluses and heparinized flushing solutions.ResultsA total of 108 completed questionnaires were received. More than 80% of respondents used heparinized saline with varying concentrations; the most prevalent was 1,000 IU/l (international units of heparin per liter) and 5,000 IU/l. Fifty-one percent of interventionalists use 3,000 IU as their standard bolus dose; however, the respondents were split regarding the timing of bolus dose with ∼60% administering it after arterial access is obtained and 40% after crossing the lesion. There was no consensus on altering dose according to body weight, and only 4% monitored clotting parameters. Conclusions: There seems to be some coherence among practicing interventionalists regarding heparin administration. We hypothesize that heparinized saline should be used at a recognized standard concentration of 1,000 IU/l as a flushing concentration in all arterial vascular interventions and that 3,000 IU bolus is considered the standard dose for straightforward therapeutic procedures and 5000 IU for complex, crural, and endovascular aneurysm repair work. The bolus should be given after arterial access is obtained to allow time for optimal anticoagulation to be achieved by the time of active intervention and stenting. Further research into clotting abnormalities following such interventional procedures would be an interesting quantifiable follow-up to this initial survey of opinions and practice.

  3. Pilot study of the dose in crystalline lens in the interventional radiology practice

    International Nuclear Information System (INIS)

    Castro, A.; Martinez, A.; Fernandez, A.; Molina, D.; Sanchez, L.; Diaz, A.

    2014-08-01

    The interventional radiology involves considerable exposure levels for the occupationally exposed personnel (OEP). The doses can encompass a wide range of values in dependence of the function that develops the personnel and the complexity of each procedure. In organs like the crystalline lens and skin values can be reached that imply the appearance of deterministic effects if is not fulfilled the appropriate measures of radiological protection. This has been demonstrated through multiple studies, among those that the retrospective study of damages in the crystalline lens and dose has been one of those most commented, known as RELID. The objective of that study was to examine the opacity prevalence in the crystalline lens in workers linked to the interventional cardiology and to correlate it with the occupational exposition. The obtained results contributed to that the ICRP recommend a new limit value of equivalent dose for crystalline lens of 20 mSv in one year. With the objective of analyzing the operational implications, in the radiological surveillance programs that they could originate with the new recommendations was developed a pilot study to evaluate the dose in crystalline lens in the OEP linked to the interventional radiology in a Cuban hospital. For this, an anthropomorphic mannequin RANDO-ALDERSON was used on which thermoluminescent dosimeters were placed below and above of the leaded apron and in different positions at level of the crystalline lens: above, below and to the sides of the leaded lenses that the personnel uses routinely. The mannequin was located on the same positions that occupy the main specialist that execute the procedure, as well as of the nurse to assist him. The measurements were made simulating the more representative procedures about complexity, duration time and exposure rate. The used dosimeters were RADOS model for whole body composed of two thermoluminescent detectors Gr-200 (LiF: Mg, Cu, P) to evaluate personal equivalent dose

  4. Computational radiology for orthopaedic interventions

    CERN Document Server

    Li, Shuo

    2016-01-01

    This book provides a cohesive overview of the current technological advances in computational radiology, and their applications in orthopaedic interventions. Contributed by the leading researchers in the field, this volume covers not only basic computational radiology techniques such as statistical shape modeling, CT/MRI segmentation, augmented reality and micro-CT image processing, but also the applications of these techniques to various orthopaedic interventional tasks. Details about following important state-of-the-art development are featured: 3D preoperative planning and patient-specific instrumentation for surgical treatment of long-bone deformities, computer assisted diagnosis and planning of periacetabular osteotomy and femoroacetabular impingement, 2D-3D reconstruction-based planning of total hip arthroplasty, image fusion for  computer-assisted bone tumor surgery, intra-operative three-dimensional imaging in fracture treatment, augmented reality based orthopaedic interventions and education, medica...

  5. Automatic management system for dose parameters in interventional radiology and cardiology

    International Nuclear Information System (INIS)

    Ten, J. I.; Fernandez, J. M.; Vano, E.

    2011-01-01

    The purpose of this work was to develop an automatic management system to archive and analyse the major study parameters and patient doses for fluoroscopy guided procedures performed in cardiology and interventional radiology systems. The X-ray systems used for this trial have the capability to export at the end of the procedure and via e-mail the technical parameters of the study and the patient dose values. An application was developed to query and retrieve from a mail server, all study reports sent by the imaging modality and store them on a Microsoft SQL Server data base. The results from 3538 interventional study reports generated by 7 interventional systems were processed. In the case of some technical parameters and patient doses, alarms were added to receive malfunction alerts so as to immediately take appropriate corrective actions. (authors)

  6. Automatic management system for dose parameters in interventional radiology and cardiology.

    Science.gov (United States)

    Ten, J I; Fernandez, J M; Vaño, E

    2011-09-01

    The purpose of this work was to develop an automatic management system to archive and analyse the major study parameters and patient doses for fluoroscopy guided procedures performed in cardiology and interventional radiology systems. The X-ray systems used for this trial have the capability to export at the end of the procedure and via e-mail the technical parameters of the study and the patient dose values. An application was developed to query and retrieve from a mail server, all study reports sent by the imaging modality and store them on a Microsoft SQL Server data base. The results from 3538 interventional study reports generated by 7 interventional systems were processed. In the case of some technical parameters and patient doses, alarms were added to receive malfunction alerts so as to immediately take appropriate corrective actions.

  7. Radiological procedures: Quality criteria and dose optimisation: French status

    International Nuclear Information System (INIS)

    Grenier, Ph.; Marshall-Depommier, E.; Bourguignon, M.; Beauvais-March, H.; Valero, M.; Lacronique, J.F.; Frijal, G.

    2001-01-01

    The Council Directive 97/43/Euratom of June 30 1997 on health protection of individuals against the dangers of ionising radiation in relation to medical exposure has come into force on May, 13 th 2000. French health directorate has entrusted the 'Office de Protection contre les Rayonnements Ionisants (OPRI)' together with the 'Societe Francaise de Radiologie' (SFR) to implement article 6 related to radiological procedures, in order to bring into operation the principle of optimisation. The most frequent diagnostic radiology and interventional procedures (120 protocols) have been standardised in writing. Corresponding patient dosimetry has been determined from measurements on site, calculations and literature review. The criteria for optimisation have been highlighted for each protocols. With the help of the French Society of Medical Physicists (SFPM), measurements are being collected on a large scale in France. Then, knowing more precisely the patient dosimetry of each protocol, referral criteria will be reviewed and prioritised to implement the principle of justification. The authors will present and explain the chosen methodology (methodology of the Accreditation and Evaluation in Health Agency: ANAES) for completing this two years workload program, and will demonstrate clinical examples as well. (author)

  8. Radiological Work Planning and Procedures

    International Nuclear Information System (INIS)

    KURTZ, J.E.

    2000-01-01

    Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In addition, there seems to be confusion as to what should be and what should not be included in the TWD

  9. Manipulation of mental models of anatomy in interventional radiology and its consequences for design of human–computer interaction

    NARCIS (Netherlands)

    Varga, E.; Pattynama, P.M.T.; Freudenthal, A.

    2012-01-01

    Interventional radiology procedures require extensive cognitive processing from the physician. A set of these cognitive functions are aimed to be replaced by technology in order to reduce the cognitive load. However, limited knowledge is available regarding mental processes in interventional

  10. Eye dose to staff involved in interventional and procedural fluoroscopy

    International Nuclear Information System (INIS)

    McLean, D; Hadaya, D; Tse, J

    2016-01-01

    In 2011 the International Commission on Radiological Protection (ICRP) lowered the occupational eye dose limit from 150 to 20 mSv/yr [1]. While international jurisdictions are in a process of adopting these substantial changes, medical physicists at the clinical level have been advising medical colleagues on specific situations based on dose measurements. Commissioned and calibrated TLDs mounted in commercially available holders designed to simulate the measurement of Hp(3), were applied to staff involved in x-ray procedures for a one month period. During this period clinical procedure data was concurrently collected and subject to audit. The use or not of eye personal protective equipment (PPE) was noted for all staff. Audits were conducted in the cardiac catheterisation laboratory, the interventional angiography rooms and the procedural room where endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed. Significant levels of occupational dose were recorded in the cardiac and interventional procedures, with maximum reading exceeding the new limit for some interventional radiologists. No significant eye doses were measured for staff performing ERCP procedures. One outcome of the studies was increased use of eye PPE for operators of interventional equipment with increased availability also to nursing staff, when standing in close proximity to the patient during procedures. (paper)

  11. A pilot experience launching a national dose protocol for vascular and interventional radiology

    International Nuclear Information System (INIS)

    Vano, E.; Segarra, A.; Fernandez, J. M.; Ordiales, J. M.; Simon, R.; Gallego, J. J.; Del Cerro, J.; Casasola, E.; Verdu, J. F.; Ballester, T.; Sotil, J.; Aspiazu, A.; Garcia, M. A.; Moreno, F.; Carreras, F.; Canis, M.; Soler, M. M.; Palmero, J.; Ciudad, J.; Diaz, F.; Hernandez, J.; Gonzalez, M.; Rosales, P.

    2008-01-01

    The design of a national dose protocol for interventional radiology has been one of the tasks during the European SENTINEL Coordination Action. The present paper describes the pilot experience carried out in cooperation with the Spanish Society on Vascular and Interventional Radiology (SERVEI). A prospective sample of procedures was initially agreed. A common quality control of the X-ray systems was carried out, including calibration of the air kerma area product (KAP) meters. Occupational doses of the radiologists involved in the survey were also included in the survey. A total of 10 Spanish hospitals with interventional X-ray units were involved. Six hundred and sixty-four patient dose data were collected from 397 diagnostic and 267 therapeutic procedures. Occupational doses were evaluated in a sample of 635 values. The obtained KAP median/mean values (Gy.cm 2 ) for the gathered procedures were: biliary drainage (30.6/68.9), fistulography (4.5/9.8), lower limb arteriography (52.2/60.7), hepatic chemoembolisation (175.8/218.3), iliac stent (45.9/73.2) and renal arteriography (39.1/59.8). Occupational doses (mean monthly values, in mSv) were 1.9 (over apron); 0.3 (under apron) and 4.5 (on hands). With this National experience, a protocol was agreed among the SENTINEL partners to conduct future similar surveys in other European countries. (authors)

  12. Preliminary exploration of the postgraduate education reform in interventional radiology

    International Nuclear Information System (INIS)

    Ni Caifang; Ouyang Yong

    2012-01-01

    Interventional radiology now is facing many challenges. The education quality has declined, and the high-level professional talents have been lost. This paper aims to analyze the present situation of the postgraduate education and the relevant issues in the field of interventional radiology, and to make a preliminary exploration into how we can train the postgraduates to become qualified interventional radiologists with high comprehensive quality in order to meet the urgent requirements demanded by the development of interventional radiology. (authors)

  13. Reconciling quality and cost: A case study in interventional radiology

    International Nuclear Information System (INIS)

    Zhang, Li; Mahnken, Andreas; Domroese, Sascha

    2015-01-01

    To provide a method to calculate delay cost and examine the relationship between quality and total cost. The total cost including capacity, supply and delay cost for running an interventional radiology suite was calculated. The capacity cost, consisting of labour, lease and overhead costs, was derived based on expenses per unit time. The supply cost was calculated according to actual procedural material use. The delay cost and marginal delay cost derived from queueing models was calculated based on waiting times of inpatients for their procedures. Quality improvement increased patient safety and maintained the outcome. The average daily delay costs were reduced from 1275 EUR to 294 EUR, and marginal delay costs from approximately 2000 EUR to 500 EUR, respectively. The one-time annual cost saved from the transfer of surgical to radiological procedures was approximately 130,500 EUR. The yearly delay cost saved was approximately 150,000 EUR. With increased revenue of 10,000 EUR in project phase 2, the yearly total cost saved was approximately 290,000 EUR. Optimal daily capacity of 4.2 procedures was determined. An approach for calculating delay cost toward optimal capacity allocation was presented. An overall quality improvement was achieved at reduced costs. (orig.)

  14. Reconciling quality and cost: A case study in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Li; Mahnken, Andreas [University Hospital Giessen and Marburg, Philipps University of Marburg, Department of Diagnostic and Interventional Radiology, Baldinger Strasse, Marburg (Germany); Domroese, Sascha [University Hospital Giessen and Marburg, Philipps University of Marburg, Division of Controlling, Baldinger Strasse, Marburg (Germany)

    2015-10-15

    To provide a method to calculate delay cost and examine the relationship between quality and total cost. The total cost including capacity, supply and delay cost for running an interventional radiology suite was calculated. The capacity cost, consisting of labour, lease and overhead costs, was derived based on expenses per unit time. The supply cost was calculated according to actual procedural material use. The delay cost and marginal delay cost derived from queueing models was calculated based on waiting times of inpatients for their procedures. Quality improvement increased patient safety and maintained the outcome. The average daily delay costs were reduced from 1275 EUR to 294 EUR, and marginal delay costs from approximately 2000 EUR to 500 EUR, respectively. The one-time annual cost saved from the transfer of surgical to radiological procedures was approximately 130,500 EUR. The yearly delay cost saved was approximately 150,000 EUR. With increased revenue of 10,000 EUR in project phase 2, the yearly total cost saved was approximately 290,000 EUR. Optimal daily capacity of 4.2 procedures was determined. An approach for calculating delay cost toward optimal capacity allocation was presented. An overall quality improvement was achieved at reduced costs. (orig.)

  15. Symptomatic portal vein occlusion: treated by interventional radiological techniques

    International Nuclear Information System (INIS)

    Wang Maoqiang; Gu Xiaofang; Guan Jun; Wang Zhongpu; Liu Fengyong; Wang Zhiqiang

    2004-01-01

    Objective: To evaluate the efficacy and safety of the interventional radiological techniques for management of symptomatic portal vein (PV) occlusion. Methods: Nine patients with PV trunk occlusion were treated using interventional procedures. Four patients presented with abdominal pain, distention, and malabsorption; five presented with portal hypertension and repeated bleeding from esophagogastric varices. The etiologic factors were identified in all 9 patients, including post-transplantation of the liver in 2, hepatocellular carcinoma (HCC) associated with PV tumor thrombus in 3, post abdominal operative state in 1, and PV thrombosis in 3 cases. The portal access was established via a percutaneous transhepatic route in 4, and via a transjugular intrahepatic portosystemic shunt ( TIPS) approach in 5 patients. The interventional procedures included stent placement in 4, balloon angioplasty in 6, and catheter directed pharmacologic and mechanical thrombolysis in 7 patients. Results: The technical success was achieved in all cases. No complications related to the procedure occurred. Portal flow was reestablished in all patients after the procedures. Clinical improvement was seen in 3 patients with symptomatic PV thrombosis, characterized by progressive reduction of abdominal pain, distention, and diarrhea. Follow-up time ranged from 4 to 36 months. One patient with HCC died of multiple organs metastases at 11 months after the treatment . One patient died of intraabdominal sepsis and multiple organs failure 12 days after the procedure even though the antegrade flow was re-established in the main trunk of the PV. Patency of the PV trunk was confirmed by follow-up color Doppler ultrasound scan in the rest 7 patients, without recurrence of variceal bleeding or PV thrombus. Conclusions: Interventional minimally invasive procedures, including balloon angioplasty, stent placement, catheter directed local pharmacologic and mechanical thrombolysis, are safe and effective in

  16. Preliminary characterization of dose in personnel of interventional radiology

    International Nuclear Information System (INIS)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle

    2016-01-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  17. Dosimetry with slow films in Interventional Radiology; Dosimetria con peliculas lentas en Radiologia Intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Ten, J.I.; Guibelalde, E.; Fernandez, J.M.; Canevaro, L.; Ramirez, R.; Vano, E. [Grupo de Fisica Medica. Departamento de Radiologia. Facultad de Medicina. Universidad Complutense de Madrid. Martin Lagos s/n CP 28040, Madrid (Spain)

    1998-12-31

    In this work it is presented a method for evaluation of patients doses in Interventional Radiology (RI). The method proposed in this work allows the simultaneous valoration of the product dose-area (PDA), the dose in the patient skin (DES) and the distribution of the irradiated fields, all of they together with their corresponding dose levels. The latter sometimes can be essential since the possible damages in skin depend not only of the doses, but also the irradiated area. The method has been resulted adequate for to evaluate doses to patients in Interventional Radiology procedures. It was possible to apply it as a routine form seeing that its not interfering significantly in the normal development of the medical intervention. The fundamental advantages of this dosimetric method in relation with the unique PDA measure or with the utilization of TLD is that it provide information about the total irradiated area, distribution and length of fields, collimation and wedge used besides that allow to determine the most irradiated zone. The visualization of the irradiated regions and the length fields utilized suggest the possibility to optimize the realization protocols of the interventional procedure in the cases in which it is considered that the doses have been very elevated. (Author)

  18. SU-D-209-03: Radiation Dose Reduction Using Real-Time Image Processing in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kanal, K; Moirano, J; Zamora, D; Stewart, B [University Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: To characterize changes in radiation dose after introducing a new real-time image processing technology in interventional radiology systems. Methods: Interventional radiology (IR) procedures are increasingly complex, at times requiring substantial time and radiation dose. The risk of inducing tissue reactions as well as long-term stochastic effects such as radiation-induced cancer is not trivial. To reduce this risk, IR systems are increasingly equipped with dose reduction technologies.Recently, ClarityIQ (Philips Healthcare) technology was installed in our existing neuroradiology IR (NIR) and vascular IR (VIR) suites respectively. ClarityIQ includes real-time image processing that reduces noise/artifacts, enhances images, and sharpens edges while also reducing radiation dose rates. We reviewed 412 NIR (175 pre- and 237 post-ClarityIQ) procedures and 329 VIR (156 preand 173 post-ClarityIQ) procedures performed at our institution pre- and post-ClarityIQ implementation. NIR procedures were primarily classified as interventional or diagnostic. VIR procedures included drain port, drain placement, tube change, mesenteric, and implanted venous procedures. Air Kerma (AK in units of mGy) was documented for all the cases using a commercial radiation exposure management system. Results: When considering all NIR procedures, median AK decreased from 1194 mGy to 561 mGy. When considering all VIR procedures, median AK decreased from 49 to 14 mGy. Both NIR and VIR exhibited a decrease in AK exceeding 50% after ClarityIQ implementation, a statistically significant (p<0.05) difference. Of the 5 most common VIR procedures, all median AK values decreased, but significance (p<0.05) was only reached in venous access (N=53), angio mesenteric (N=41), and drain placement procedures (N=31). Conclusion: ClarityIQ can reduce dose significantly for both NIR and VIR procedures. Image quality was not assessed in conjunction with the dose reduction.

  19. Awareness of interventional radiology among patients referred to the interventional radiology department: a survey of patients in a large Canadian community hospital.

    Science.gov (United States)

    Baerlocher, Mark O; Asch, Murray R; Puri, Gaurav; Vellahottam, Andrew; Myers, Andy; Andrews, Karen

    2007-05-01

    To quantify the level of knowledge about interventional radiology (IR) among patients referred for an IR procedure and to develop recommendations on how to increase public awareness of IR. Paper surveys were prospectively administered to consecutive patients scheduled to undergo an IR procedure at a community hospital. The study was terminated at the accrual of 100 completed surveys. Totals of 28% and 6% knew generally the job of a diagnostic radiologist and interventional radiologist, respectively, and 6% had heard of the field of IR before their referral (despite 21% having undergone a procedure previously). Before their arrival in the IR department, 87% had not received any information about IR. Three percent, 0%, 4%, 82%, and 82% had heard about uterine artery embolization, radiofrequency ablation, vertebroplasty, biopsy (any type), and angioplasty, respectively. After the procedures, 84% had a clearer view of what interventional radiologists do, but 98% believed that most others did not know what IR was. When asked how best to educate the public about IR, the responses were: unsure (39%), other (19%), pamphlets (12%), information from physicians (9%), television (8%), and Internet (7%). Overall, the mean satisfaction rate was 8.8 (with 0 representing the minimum and 10 representing the maximum), and 97% would choose IR over surgery for future treatments. These data quantify and strongly support the views that (1) even among patients specifically referred to IR for a procedure, the majority of people are unaware of what the field is or may offer; and (2) most patients were satisfied with their IR experience. Six results-based recommendations are made to increase public awareness about IR.

  20. Radiation dose reduction: comparative assessment of publication volume between interventional and diagnostic radiology.

    Science.gov (United States)

    Hansmann, Jan; Henzler, Thomas; Gaba, Ron C; Morelli, John N

    2017-01-01

    We aimed to quantify and compare awareness regarding radiation dose reduction within the interventional radiology and diagnostic radiology communities. Abstracts accepted to the annual meetings of the Society of Interventional Radiology (SIR), the Cardiovascular and Interventional Radiological Society of Europe (CIRSE), the Radiological Society of North America (RSNA), and the European Congress of Radiology (ECR) between 2005 and 2015 were analyzed using the search terms "interventional/computed tomography" and "radiation dose/radiation dose reduction." A PubMed query using the above-mentioned search terms for the years of 2005-2015 was performed. Between 2005 and 2015, a total of 14 520 abstracts (mean, 660±297 abstracts) and 80 614 abstracts (mean, 3664±1025 abstracts) were presented at interventional and diagnostic radiology meetings, respectively. Significantly fewer abstracts related to radiation dose were presented at the interventional radiology meetings compared with the diagnostic radiology meetings (162 abstracts [1% of total] vs. 2706 [3% of total]; P radiology abstracts (range, 6-27) and 246±105 diagnostic radiology abstracts (range, 112-389) pertaining to radiation dose were presented at each meeting. The PubMed query revealed an average of 124±39 publications (range, 79-187) and 1205±307 publications (range, 829-1672) related to interventional and diagnostic radiology dose reduction per year, respectively (P radiology community over the past 10 years has not mirrored the increased volume seen within diagnostic radiology, suggesting that increased education and discussion about this topic may be warranted.

  1. Monte Carlo calculations on extremity and eye lens dosimetry for medical staff at interventional radiology procedures

    International Nuclear Information System (INIS)

    Carinou, E.; Ferrari, P.; Koukorava, C.; Krim, S.; Struelens, L.

    2011-01-01

    There are many factors that can influence the extremity and eye lens doses of the medical staff during interventional radiology and cardiology procedures. Numerical simulations can play an important role in evaluating extremity and eye lens doses in correlation with many different parameters. In the present study, the first results of the ORAMED (Optimisation of Radiation protection of Medical staff) simulation campaign are presented. The parameters investigated for their influence on eye lens, hand, wrist and leg doses are: tube voltage, filtration, beam projection, field size and irradiated part of the patient's body. The tube voltage ranged from 60 to 110 kVp, filtration from 3 to 6 mm Al and from 0 to 0.9 mm Cu. For all projections, the results showed that doses received by the operator decreased with increasing tube voltage and filtration. The magnitude of the influence of the tube voltage and the filtration on the doses depends on the beam projection and the irradiated part of the patient's body. Finally, the influence of the field size is significant in decreasing the doses. (authors)

  2. Experimental method for calculation of effective doses in interventional radiology; Metodo experimental para calculo de dosis efectivas en radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz Lblanca, M. D.; Diaz Romero, F.; Casares Magaz, O.; Garrido Breton, C.; Catalan Acosta, A.; Hernandez Armas, J.

    2013-07-01

    This paper proposes a method that allows you to calculate the effective dose in any interventional radiology procedure using an anthropomorphic mannequin Alderson RANDO and dosimeters TLD 100 chip. This method has been applied to an angio Radiology procedure: the biliary drainage. The objectives that have been proposed are: to) put together a method that, on an experimental basis, allows to know dosis en organs to calculate effective dose in complex procedures and b) apply the method to the calculation of the effective dose of biliary drainage. (Author)

  3. 100 classic papers of interventional radiology: A citation analysis.

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan Fj; MacMahon, Peter J; Lawler, Leo

    2015-04-28

    To define the 100 citation classic papers of interventional radiology. Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. The top paper received 2497 citations and the 100(th) paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with "Radiology" and "AJR" making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty.

  4. Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign

    International Nuclear Information System (INIS)

    Nikodemová, D.; Brodecki, M.; Carinou, E.; Domienik, J.; Donadille, L.; Koukorava, C.; Krim, S.; Ruiz-López, N.; Sans-Merce, M.; Struelens, L.; Vanhavere, F.; Zaknoune, R.

    2011-01-01

    The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10–12% increase in the number of IR examinations every year (). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed. The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses. -- Highlights: ► We present a set of data on extremity doses for staff in selected interventional radiology procedures. ► We studied the influence of different parameters. ► The measured doses are analyzed according to the operators skill,his position during work, tube configuration, etc. ► Maximum doses recorded for all types of embolisation, in all

  5. Interventional radiology as clinical specialty and how this affects the radiology specialty as a whole

    International Nuclear Information System (INIS)

    Tsetis, D.

    2015-01-01

    Full text: Interventional Radiologists (IRs) are medical doctors who are trained in imaging but have undergone additional specialist training in highly demanding image-guided techniques. For this reason they play an increasingly important clinical role which is expanding beyond IR/angiography suite. As IR practice is fundamentally different from diagnostic imaging, the Radiology departments should be adapted to facilitate this special task. Interventional Radiologists should be able to fulfil their task as patient’s primary doctor and exert direct clinical responsibility for the patient under their care. They should be able to clinically assess and counsel patients before a procedure, inform them about the risks of the procedure and possible alternative treatment options, obtain valid consent and follow-up them after the procedure. they should also effectively communicate with referring physicians and develop strategies to deal with complex clinical situations and difficult clinical scenarios. In this context it is imperative for IRs to participate regularly in multidisciplinary clinical meetings and multidisciplinary forums to ensure optimum care. As clinicians, IR’s must be involved with the day to day management of their patients’ care to ensure optimal outcomes for patients. This may involve shared care with a broad range of specialists, however IR’s should aim to have direct access to inpatients beds where they can admit and discharge patients as necessary, with sufficient time allocated for this activity. As the number and demand of IR day cases steadily increases, IR units should organize day case facilities staffed with nursing and clerical staff which can result in major cost savings to hospitals. In this context the Head of Radiology department should convince hospital authorities to establish outpatient clinic facilities with nursing and clerical support where referred patients can be counselled and reviewed in a quiet environment. In order to

  6. Interventional Radiologic Treatment for Idiopathic Portal Hypertension

    International Nuclear Information System (INIS)

    Hirota, Shozo; Ichikawa, Satoshi; Matsumoto, Shinichi; Motohara, Tomofumi; Fukuda, Tetsuya; Yoshikawa, Takeshi

    1999-01-01

    Purpose: To evaluate the usefulness of interventional radiological treatment for idiopathic portal hypertension. Methods: Between 1995 and 1998, we performed an interventional radiological treatment in five patients with idiopathic portal hypertension, four of whom had refused surgery and one of whom had undergone surgery. Three patients with gastroesophageal varices (GEV) were treated by partial splenic embolization (PSE), one patient with esophageal varices (EV) and massive ascites by transjugular intrahepatic portosytemic shunt (TIPS) and PSE, and one patient with GEV by percutaneous transhepatic obliteration (PTO). Midterm results were analyzed in terms of the effect on esophageal and/or gastric varices. Results: In one woman with severe GEV who underwent three sessions of PSE, there was endoscopic confirmation that the GEV had disappeared. In one man his EV shrunk markedly after two sessions of PSE. In two patients slight reduction of the EV was obtained with one application of PSE combined with endoscopic variceal ligation therapy. PTO for GV in one patient resulted in good control of the varices. All patients have survived for 16-42 months since the first interventional treatment, and varices are well controlled. Conclusion: Interventional radiological treatment is effective for patients with idiopathic portal hypertension, whether or not they have undergone surgery

  7. Effective dose to patients in interventional vascular radiology in Malaga and Tenerife

    International Nuclear Information System (INIS)

    Ruiz Cruces, R.; Perez Martinez, M.; Diez de los Rios Delgado, A.; Hernandez Armas, J.; Garcia-Granados, J.; Diaz Romero, F.J.

    1997-01-01

    The objective of the research is to estimate the effective dose that patients receive during the procedure of interventional vascular radiology screening using a digital system. The effective dose is the best indicator of radiological risks. A plane ionization camera is used to estimate dose per surface area (Gy/square cm). By means of the method described in the NRPB R-262 report, projections were selected which adjust to the field irradiated in each of the procedures analysed. The product values of the dose surface and effective dose has been 75.7 Gy/cm 2 and 10.5 mSv for abdominal angiography; 29.0 Gy/cm 2 and 7.6 mSv for arteriographic diagnosis of the inferior members; 104.5 Gy/cm 2 and 23.6 mSv for gall drainage; 90.5 Gy/cm 2 and 21.5 mSv for varicoceles, and 39.5 Gy/cm 2 and 9.6 mSv for nephrostomas

  8. Radiological protection optimization derived from radiation induced lesions in interventional cardiology finding

    International Nuclear Information System (INIS)

    Vano, E.; Arranz, L.; Sastre, J.M.; Ferrer, N.

    1997-01-01

    Interventional Cardiology is one of the specialties in which patients are submitted to the greatest radiation doses with x ray systems used for diagnostic purposes and then, it is also a specialty of high occupational radiation risk. In the last years, several cases of radiation induced lesions produced on patients derived of new complex interventional procedures have been described. As consequence, different rules for avoiding this kind of incidents have been recommended by International Organisations and regulatory Bodies. Nevertheless it has been devoted relatively few attention to the evaluation of the occupational risks that inevitably are also high in these facilities. In this work, some cases of radioinduced skin lesions produced on patients submitted to cardiac ablation procedures are described. Radiological protection considerations of interest for the regulatory Bodies are made, that permit to minimize the probability of these incidents, in what to the X-rays equipment is referred as well as to the operation procedures and level of radiation protection training of the medical specialists. (author)

  9. Eye lens dose estimation during interventional radiology and its impact on the existing radiation protection and safety program: in the context with new International Commission on Radiological Protection guidelines

    International Nuclear Information System (INIS)

    Chaudhari, Suresh

    2014-01-01

    Interventional radiology procedures are used for diagnosing certain medical conditions. The radiologists and medical professionals are exposed to ionizing radiation from X-rays of the equipments and also from scattered radiation during these procedures. The radiation exposure to the eye is more important to be assessed while performing such procedures. ICRP has revised the annual dose limit to the lens of the eye from 150 mSv to 20 mSv. In view of this revision, a study was carried out to evaluate the dose to the lens of the eye during interventional radiology. The paper gives the details of calibration of TLDs using a head phantom, predict annual equivalent dose and also highlight the dependence of dose on the position of TLD on the head. It is observed the predicted annual equivalent doses to the lens of eye are in the range of 25 mGy to 37 mGy. The selection of dosimeter placement may also result in an uncertainty of -14% to 20%. (author)

  10. Recommendations for equipment requirements and specifications for digital and interventional radiology: Dosimetric aspects

    International Nuclear Information System (INIS)

    Suliman, I.I.; Zoetelief, J.

    2002-01-01

    The recognition of radiation induced injuries from fluoroscopically guided interventional procedures has resulted in the current demand for development of recommendations and standards to limit dose to both patients and staff. This paper outlines the recommendations drafted within the framework of European Project DIMOND III. The actual work involves survey and review of national and international documents as well as scientific publications in areas relevant to the digital and/or interventional radiology with an aim of developing recommendations for equipment requirements and specifications for digital and interventional radiology. A pilot study of experimental investigations in at least three hospitals will be conducted to test the requirements and the specifications, the result of which will be presented. The recommendations are expected to provide an effective means of dose reduction to both patients and staff while maintaining image quality adequate for the specific diagnosis or interventional procedure. Different components of x-ray systems that have direct impact on patient and staff doses have been considered. Where necessary a compromise between patient dose and image quality has been made. The dosimetric aspects of the recommendations propose detailed descriptions and limits to dosimetric information relevant to patient and staff doses. International recommendations on maximum patient entrance surface dose rate vary in the range from 25 to 65 mGy.min -1 for normal mode fluoroscopy. Maximum image intensifier or image receptor input dose rate around 0.1 Gy min -1 at a distance 30 cm from the image intensifier input surface has been generally recommended. Maximum fluoroscopic dose rate in air must not exceed 50 mGy.min -1 at a location depending on the configuration e.g. for undertable x-ray tube at 10 mm from the patient support on the patient side of the support. The use of pulsed fluoroscopy or low dose fluoroscopy is proposed as good options to minimize

  11. A survey of nurse staffing levels in interventional radiology units throughout the UK

    International Nuclear Information System (INIS)

    Christie, A.; Robertson, I.

    2016-01-01

    Aim: To supplement previous surveys analysing provision of interventional radiology (IR), in-hours (IH) and out-of-hours (OOH), by specifically surveying the level of nursing support provided. Materials and methods: A web-based questionnaire was distributed to all British Society of Interventional Radiology (BSIR) members. This addressed several aspects of radiology nursing support for IR procedures, both IH and OOH. Results: Sixty percent of respondents indicated that they have a formal OOH service. Of these, all have a dedicated nursing rota, with the vast majority operating with one nurse. IH, 77% of respondents always have a scrubbed nurse assistant, but this reduces to 40% OOH. IH, 4% never have a scrubbed radiology nurse assistant, which rises to 25% OOH. IH, 75% of respondents always have a radiology nurse dedicated to patient monitoring, but this reduces to 20% OOH. IH, 3% never have a radiology nurse dedicated to patient monitoring, which rises to 42% OOH. Conclusion: A significant disparity exists in the level of IR nursing support between IH and OOH. The majority of sites provide a single nurse with ad hoc additional support. This is potentially putting patients at increased risk. Radiology nurses are integral to the safe and sustainable provision of IR OOH services and a greater focus is required to ensure adequate and safe staffing levels for 24/7 IR services. - Highlights: • A significant disparity exists between the level of nursing support provided in-hours and OOH. • This applies to both the availability of a nurse to scrub and to monitor the patient. • Having a dedicated 24/7 nursing rota is mandatory to providing a deliverable OOH service.

  12. Interventional radiology in cardiov ascular division of radiology department S.N.U hospital{sub s}taff roles and departmental management

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Chul; Cheung, Hwan [Seoul National University Hospital, Seoul (Korea, Republic of)

    1986-11-15

    As the angiography in the field of radiological sciences is being increasingly diversified in its techniques, clinical applications of interventional radiology are rapidly increasing not only for its usefulness in simple diagnosis but for its capabilities of affording, by means of radiological surveillance, biological data such as those concerning tissues which are even substitutionary or supplementary to treatment of diseases. During the last 5 years from July 1980 to 1984 such applications in the cardiovascular division showed a trend of radical increase and thus emerging as a new domain of radiological medicine which has vast influence on diagnosis and treatment. The present treatise presents the results of research performed on the following: 1) Need for close coordination among physicians, radiologists, and nurses in the radiology department. 2) Need for prior explanation to the patient of the procedure to be followed to relieve his anxiety. 3) Checking of the angiographic equipment and selection of technical factors. 4) Proper management of manpower including medical radiologists and assistant radiologists. 5) Sterilization of auxiliary equipment required for surgical operation. 6) Selection of a catheter and control of clinical materials such as contrast agents. 7) Supplementary arrangements for speedy performance of clinical services.

  13. The interplay of ultrasound and computed tomography in the planning and execution of interventional procedures

    International Nuclear Information System (INIS)

    Stafford, S.; Mueller, P.R.

    1987-01-01

    Even in large academic and private settings, where subspecialists abound and diagnostic and interventional radiologists are divided, both physically and philosophically, the interventionalist has emerged from the fluoroscopic suite to participate in the imaging workup of patients referred for precutaneous procedures. This expanded imaging role for the interventionalist is a natural outgrowth of several developments in radiology training. Computed tomography and ultrasound no longer are obscure techniques, understood only by an elite group of academic radiologists in large centers with access to equipment. All residents receive extensive education in these modalities, as imaging is a major part of general radiology. In addition, fellowship programs have been expanded to emphasize organ system training as opposed to ''modality'' training alone. Armed with imaging skills, the interventionalist is able to evaluate the cross-sectional diagnostic images better and to address specific findings and issues with respect to the planned procedure. These specific issues, elucidated by cross-sectional imaging, impact on the planning of interventional procedures addressed in this chapter

  14. Basic principles for intervention after a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    Per Hedemann Jensen

    1996-01-01

    The current status of internationally agreed principles for intervention after a nuclear accident or radiological emergency and the international development of intervention guidance since the Chernobyl accident are reviewed. The experience gained after the Chernobyl accident indicates that the international advice on intervention existing at the time of the Chernobyl accident was not fully understood by decision makers neither in Western Europe nor in the former USSR and that the guidance failed to address adequately the difficult social problems which can arise after a serious nuclear accident. The radiation protection philosophy of today distinguishes between practices and interventions. The radiological protection system of intervention includes justification of the protective action and optimization of the level of protection achieved by that action. Dose limits do not apply in intervention situations. The inputs to justification and optimization studies include factors that are related to radiological protection, whereas the final decisions on introduction of countermeasures would also depend on other factors. The basic principles for intervention as recommended by international organisations are discussed in detail and the application of the principles on a generic basis is illustrated for long-term protective actions. The concepts of intervention level, operational intervention level and action level are presented and the relation between these quantities is illustrated. The numerical guidance on intervention in a nuclear accident or radiological emergency or a chronic exposure situation given by ICRP, IAEA and in the Basic Safety Standards is presented. (author)

  15. Assessment of eye lens doses in interventional radiology: a simulation in laboratory conditions

    International Nuclear Information System (INIS)

    Cemusova, Z.; Ekendahl, D.; Judas, L.

    2016-01-01

    As workers in interventional radiology belong to one of the most occupationally exposed groups, methods for sufficiently accurate quantification of their external exposure are sought. The objective of the authors' experiment was to investigate the relations between eye lens dose and H p (10), H p (3) or H p (0.07) values measured with a conventional whole-body personal thermoluminescence dosemeter (TLD). Conditions of occupational exposure during common interventional procedures were simulated in laboratory. An anthropomorphic phantom represented a physician. The TLDs were fixed to the phantom in different locations that are common for purposes of personal dosimetry. In order to monitor the dose at the eye lens level during the exposures, a special thermoluminescence eye dosemeter was fixed to the phantom's temple. Correlations between doses measured with the whole-body and the eye dosemeters were found. There are indications that personnel in interventional radiology do not need to be unconditionally equipped with additional eye dosemeters, especially if an appropriate whole-body dosimetry system has been already put into practice. (authors)

  16. Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85

    Energy Technology Data Exchange (ETDEWEB)

    Valentin, J

    2000-06-01

    Interventional radiology (fluoroscopically-guided) techniques are being used by an increasing number of clinicians not adequately trained in radiation safety or radiobiology. Many of these interventionists are not aware of the potential for injury from these procedures or the simple methods for decreasing their incidence. Many patients are not being counselled on the radiation risks, nor followed up when radiation doses from difficult procedures may lead to injury. Some patients are suffering radiation-induced skin injuries and younger patients may face an increased risk of future cancer. Interventionists are having their practice limited or suffering injury, and are exposing their staff to high doses. In some interventional procedures, skin doses to patients approach those experienced in some cancer radiotherapy fractions. Radiation-induced skin injuries are occurring in patients due to the use of inappropriate equipment and, more often, poor operational technique. Injuries to physicians and staff performing interventional procedures have also been observed. Acute radiation doses (to patients) may cause erythema at 2 Gy, cataract at 2 Gy, permanent epilation at 7 Gy, and delayed skin necrosis at 12 Gy. Protracted (occupational) exposures to the eye may cause cataract at 4 Gy if the dose is received in less than 3 months, at 5.5 Gy if received over a period exceeding 3 months. Practical actions to control dose to the patient and to the staff are listed. The absorbed dose to the patient in the area of skin that receives the maximum dose is of priority concern. Each local clinical protocol should include, for each type of interventional procedure, a statement on the cumulative skin doses and skin sites associated with the various parts of the procedure. Interventionists should be trained to use information on skin dose and on practical techniques to control dose. Maximum cumulative absorbed doses that appear to approach or exceed 1 Gy (for procedures that may be

  17. Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85

    International Nuclear Information System (INIS)

    Valentin, J.

    2000-01-01

    Interventional radiology (fluoroscopically-guided) techniques are being used by an increasing number of clinicians not adequately trained in radiation safety or radiobiology. Many of these interventionists are not aware of the potential for injury from these procedures or the simple methods for decreasing their incidence. Many patients are not being counselled on the radiation risks, nor followed up when radiation doses from difficult procedures may lead to injury. Some patients are suffering radiation-induced skin injuries and younger patients may face an increased risk of future cancer. Interventionists are having their practice limited or suffering injury, and are exposing their staff to high doses. In some interventional procedures, skin doses to patients approach those experienced in some cancer radiotherapy fractions. Radiation-induced skin injuries are occurring in patients due to the use of inappropriate equipment and, more often, poor operational technique. Injuries to physicians and staff performing interventional procedures have also been observed. Acute radiation doses (to patients) may cause erythema at 2 Gy, cataract at 2 Gy, permanent epilation at 7 Gy, and delayed skin necrosis at 12 Gy. Protracted (occupational) exposures to the eye may cause cataract at 4 Gy if the dose is received in less than 3 months, at 5.5 Gy if received over a period exceeding 3 months. Practical actions to control dose to the patient and to the staff are listed. The absorbed dose to the patient in the area of skin that receives the maximum dose is of priority concern. Each local clinical protocol should include, for each type of interventional procedure, a statement on the cumulative skin doses and skin sites associated with the various parts of the procedure. Interventionists should be trained to use information on skin dose and on practical techniques to control dose. Maximum cumulative absorbed doses that appear to approach or exceed 1 Gy (for procedures that may be

  18. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  19. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  20. Assessment of radiological properties of wastes from urban decontamination procedures

    International Nuclear Information System (INIS)

    Da Silva, D.N.G.; Guimarães, J.R.D.; Rochedo, E.R.R.; Rochedo, P.R.R.; De Luca, C.

    2015-01-01

    One important activity associated to urban areas contaminated from accidental releases to the atmosphere of nuclear power plants is the management of radioactive wastes generated from decontamination procedures. This include the collection, conditioning, packing, transport and temporary/final disposition. The final destination is defined usually through a political decision. Thus, transport of packed radioactive wastes shall depend on decisions not just under the scope of radiological protection issues. However, the simulations performed to assess doses for the public and decontamination workers allows the estimate of radiological aspects related to the waste generated and these characteristics may be included in a multi-criteria decision tool aiming to support, under the radiological protection point of view, the decision-making process on post-emergency procedures. Important information to decision makers are the type, amount and activity concentration of wastes. This work describes the procedures to be included in the urban area model to account for the assessment of qualitative and quantitative description of wastes. The results will allow the classification of different procedures according to predefined criteria that shall then feed the multi-criteria assessment tool, currently under development, considering basic radiological protection aspects of wastes generated by the different available cleanup procedures on typical tropical urban environments. (authors)

  1. Approaching the Practice Quality Improvement Project in Interventional Radiology.

    Science.gov (United States)

    Reis, Stephen P; White, Benjamin; Sutphin, Patrick D; Pillai, Anil K; Kalva, Sanjeeva P; Toomay, Seth M

    2015-12-01

    An important component of maintenance of certification and quality improvement in radiology is the practice quality improvement (PQI) project. In this article, the authors describe several methodologies for initiating and completing PQI projects. Furthermore, the authors illustrate several tools that are vital in compiling, analyzing, and presenting data in an easily understandable and reproducible manner. Last, they describe two PQI projects performed in an interventional radiology division that have successfully improved the quality of care for patients. Using the DMAIC (define, measure, analyze, improve, control) quality improvement framework, interventional radiology throughput has been increased, to lessen mediport wait times from 43 to 8 days, and mediport infection rates have decreased from more than 2% to less than 0.4%. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. 100 classic papers of interventional radiology: A citation analysis

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan FJ; MacMahon, Peter J; Lawler, Leo

    2015-01-01

    AIM: To define the 100 citation classic papers of interventional radiology. METHODS: Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. RESULTS: The top paper received 2497 citations and the 100th paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with “Radiology” and “AJR” making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. CONCLUSION: This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty. PMID:25918585

  3. Determining procedures for simulation-based training in radiology

    DEFF Research Database (Denmark)

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth

    2018-01-01

    , and basic abdominal ultrasound. CONCLUSION: A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. KEY POINTS: • Simulation-based training can supplement training on patients......OBJECTIVES: New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs...... assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. METHODS: A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored...

  4. National radiology standards in X-ray diagnostic incl. interventional radiology

    International Nuclear Information System (INIS)

    Valek, V.; Kratochvil, P.

    2005-01-01

    In 2004 the Ministry of Health care started within the frame of the program for support of quality in health care a project consisting of 4 separate tasks: creating of standards for medical irradiation in radiodiagnostics, in radiotherapy , in nuclear medicine and creating of standards for patients dose assessment in radiophysics. This document continues with description of a part of the project aimed on X-ray radiodiagnostics. The authors of the project were chosen based on their bids to the public grant issued by the Ministry of Health care. The authors used recommendations, guidelines and instructions of international professional societies and IAEA, as well as the already existing procedures and practices while considering possibilities and state of the praxis in the Czech Republic. The outcome of authors work is now an interim version of a document that will be published in the bulletin of the Ministry of Health care. The document contains a set of standards that cover the whole range o fall complimentarily performed ways of patients irradiation in X-ray diagnostics and interventional radiology . The standards are divided to several categories according to the requirement of the Ministry of Health care based on the diagnostic appliances used for diagnostic irradiation i.e. radiography , fluoroscopy, mammography, stomatology, computer tomography, angiography, interventional radiography and cardiography. (authors)

  5. The role of interventional radiology in the management of intra-and extra-Peritoneal leakage in patients who have undergone continent urinary diversion

    International Nuclear Information System (INIS)

    Bodner, Leonard; Nosher, John L.; Siegel, Randall; Russer, Tadeus; Cummings, Kenneth; Kraus, Stephen

    1997-01-01

    Purpose. To assess how radiologic intervention altered the hospital course of patients undergoing continent urinary diversion. Methods. Thirty-seven consecutive patients with bladder cancer invading the muscular layer were treated with total cystectomy and construction of a continent urinary reservoir. Eleven of 37 patients suffered early and late anastomotic leakage; six had prolonged extraperitoneal leakage at the urethroenteric anastomosis, three had prolonged intraperitoneal pouch leaks, and two had delayed ureteroenteric leaks. Seven of these patients required radiologic intervention.Results. Intervention in the form of drainage catheter manipulation (n=4), percutaneous nephrostomy (n=4), or ureteral stent placement (n=2) resulted in cessation of leakage without surgical intervention in all seven patients. Intraperitoneal pouch leaks were more difficult to control than extraperitoneal leakage and required longer drainage intervals.Conclusion. Interventional radiologic procedures played a key role in the management of continent urinary diversion complications obviating the need for repeat surgical intervention in all instances

  6. Attention to the application of vein anaesthesia in interventional radiology

    International Nuclear Information System (INIS)

    Xie Zonggui; Cheng Yongde

    2006-01-01

    Interventional radiology is mostly carried out under local anesthesia with micro invasive characteristics. However, the questions of patient's pain, nerve intense, change of blood pressure and heart rate always influence the performance of operation. General anaesthesia in interventional radiology is a comparatively simple venous anaesthesia modality with a controlled dose of anesthetics injecting via periphery vein through persistent minimally injecting pump to keep the patient in dormancy under electrocardiographic monitoring. It doesn't require a tube insertion of trachea. The anaesthesia depth and time are under control. The half-life of the anaesthesia drugs is short with less side-effect. It is necessary to introduce the advanced anaesthesia into common interventional radiological therapy with attentions of promoting the development through new modalities. (authors)

  7. Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Pasciak, Alexander S. [Department of Radiology, The University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37922 (United States); Wagner, Louis K. [Department of Diagnostic and Interventional Imaging, The John P. and Katharine G. McGovern Medical School, Houston, Texas 77030 (United States)

    2016-07-15

    Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

  8. Optimizing Travel Time to Outpatient Interventional Radiology Procedures in a Multi-Site Hospital System Using a Google Maps Application.

    Science.gov (United States)

    Mandel, Jacob E; Morel-Ovalle, Louis; Boas, Franz E; Ziv, Etay; Yarmohammadi, Hooman; Deipolyi, Amy; Mohabir, Heeralall R; Erinjeri, Joseph P

    2018-02-20

    The purpose of this study is to determine whether a custom Google Maps application can optimize site selection when scheduling outpatient interventional radiology (IR) procedures within a multi-site hospital system. The Google Maps for Business Application Programming Interface (API) was used to develop an internal web application that uses real-time traffic data to determine estimated travel time (ETT; minutes) and estimated travel distance (ETD; miles) from a patient's home to each a nearby IR facility in our hospital system. Hypothetical patient home addresses based on the 33 cities comprising our institution's catchment area were used to determine the optimal IR site for hypothetical patients traveling from each city based on real-time traffic conditions. For 10/33 (30%) cities, there was discordance between the optimal IR site based on ETT and the optimal IR site based on ETD at non-rush hour time or rush hour time. By choosing to travel to an IR site based on ETT rather than ETD, patients from discordant cities were predicted to save an average of 7.29 min during non-rush hour (p = 0.03), and 28.80 min during rush hour (p travel time when more than one location providing IR procedures is available within the same hospital system.

  9. Work procedures and risk factors for high rdiation exposure among radiologic technologists in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Young; Choi, Yeong Chull [Dept. of Preventive Medicine, Keimyung University College of Medicine, Daegu (Korea, Republic of); Lee, Won Jin; Cha, Eun Shil [Dept. of Preventive Medicine, Korea University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.

  10. Work procedures and risk factors for high rdiation exposure among radiologic technologists in South Korea

    International Nuclear Information System (INIS)

    Kim, Jae Young; Choi, Yeong Chull; Lee, Won Jin; Cha, Eun Shil

    2016-01-01

    Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.

  11. Estimated occupational dose in interventional procedures crystalline; Estimacion de la dosis ocupacional en el cristallino en procedimientos interveniconistas

    Energy Technology Data Exchange (ETDEWEB)

    Portas Ferradas, B. C.; Chapel Gomez, M. L.; Jimenez Alarcon, J. I.

    2011-07-01

    This paper present the result of the estimated doses in the eyes of workers exposed for radiology procedures and interventional cardiology from measurements made with thermoluminescent dosimeter placed near the lens.

  12. Nanotechnology and its relationship to interventional radiology. Part I: imaging.

    LENUS (Irish Health Repository)

    Power, Sarah

    2011-04-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  13. Nanotechnology and its relationship to interventional radiology. Part I: imaging.

    LENUS (Irish Health Repository)

    Power, Sarah

    2012-02-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  14. Nanotechnology and its Relationship to Interventional Radiology. Part I: Imaging

    International Nuclear Information System (INIS)

    Power, Sarah; Slattery, Michael M.; Lee, Michael J.

    2011-01-01

    Nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Interventional radiology stands to benefit greatly from advances in nanotechnology because much of the ongoing research is focused toward novel methods of imaging and delivery of therapy through minimally invasive means. Through the development of new techniques and therapies, nanotechnology has the potential to broaden the horizon of interventional radiology and ensure its continued success. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part I of the article deals with an introduction to some of the basic concepts of nanotechnology and outlines some of the potential imaging applications, concentrating mainly on advances in oncological and vascular imaging.

  15. Role of interventional radiology in the management of acute gastrointestinal bleeding

    Science.gov (United States)

    Ramaswamy, Raja S; Choi, Hyung Won; Mouser, Hans C; Narsinh, Kazim H; McCammack, Kevin C; Treesit, Tharintorn; Kinney, Thomas B

    2014-01-01

    Acute gastrointestinal bleeding (GIB) can lead to significant morbidity and mortality without appropriate treatment. There are numerous causes of acute GIB including but not limited to infection, vascular anomalies, inflammatory diseases, trauma, and malignancy. The diagnostic and therapeutic approach of GIB depends on its location, severity, and etiology. The role of interventional radiology becomes vital in patients whose GIB remains resistant to medical and endoscopic treatment. Radiology offers diagnostic imaging studies and endovascular therapeutic interventions that can be performed promptly and effectively with successful outcomes. Computed tomography angiography and nuclear scintigraphy can localize the source of bleeding and provide essential information for the interventional radiologist to guide therapeutic management with endovascular angiography and transcatheter embolization. This review article provides insight into the essential role of Interventional Radiology in the management of acute GIB. PMID:24778770

  16. Accidental exposures in interventional radiology: lessons learned by the ASN

    International Nuclear Information System (INIS)

    Marchal, C.; Valero, M.

    2009-01-01

    The authors outline that interventional radiology often requires long duration exposures of patients to ionizing radiations and thus stress that interventional radiology must be optimized to improve radioprotection of patients and operators. They notice that investigations performed by the ASN (the French Nuclear Safety Authority) on declared events revealed in some cases a lack of knowledge of devices by users, notably of functionalities allowing the applied doses to be controlled

  17. Sedoanalgesia in interventional radiology

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Pfeifer, K.J.; Reiser, M.

    2002-01-01

    Purpose: Development of a save and effective protocol for analgosedation of patients undergoing painful interventional procedures. Material and Methods: In a prospective trial a consecutive series of 72 adult patients underwent analgosedation during painful interventions. A radiologist performed the analgosedation, the patients received a combination of a shortly effective piperidine derivative (Alfentanil [Rapifen trademark ]; 7.5-15 μg/kg body weight) and Benzodiazepine (midazolam [Dormicum trademark ]; 20 μg/kg body weight). After pre-procedure oxygenation patients were continuously monitored. Pain and discomfort were scored using an established visual-analog pain score (0-10). A control group (n=24) had received midazolam, pentazocine or fentanyl according to the study protocol. Results: All procedures could be carried out by an interventional radiologist and a nurse and/or technologist only. In 69/72 cases adequate analgosedation could be achieved. Injection of alfentanil was titrated, with a rapid onset and short acting effect of the analgesia. Patients reported an average pain score of 2.6 vs. 4.5 in the control group. Over 55% experienced no or mild pain (score 0-3), in the control group only 8% reached this level. Conclusion: A combination of shortly effective alfentanil and midazolam allows interventional radiologists to perform major procedures alone under effective analgosedation. This medication scheme is superior to the medication upon demand. (orig.) [de

  18. Relevant radiological anatomy of the pig as a training model in interventional radiology

    International Nuclear Information System (INIS)

    Dondelinger, R.F.; Ghysels, M.P.; Brisbois, D.; Donkers, E.; Snaps, F.R.; Saunders, J.; Deviere, J.

    1998-01-01

    The use of swine for teaching purposes in medicine and surgery has largely increased in recent years. Detailed knowledge of the porcine anatomy and physiology is a prerequisite for proper use of pigs as a teaching or an experimental model in interventional radiology. A systematic study of the radiological anatomy was undertaken in more than 100 female pigs aged 6-8 weeks. All studies were performed under general anesthesia in a single session. Animals were sacrificed at the end of the study. Selective angiographies were systematically obtained in all anatomical territories. In other animals CT and MRI examinations were performed and were correlated to anatomical sections and acrylic casts of the vascular structures. Endoscopical examinations of the upper gastrointestinal tract, including retrograde opacification of the biliary and pancreatic ducts, were added in selected animals. The main angiographic aspects of the brain, head and neck, thorax, abdomen, and pelvis were recorded. Similarities and differences in comparison with human anatomy are stressed. Potential applications in interventional radiology are indicated. (orig.)

  19. Radiation exposures received by the staff in the interventional radiology unit

    International Nuclear Information System (INIS)

    Vekic, Branko; Miljanic, S.; Ban, R.; Ranogajec-Komor, M.; Stern-Padovan, R.; Basic, B.

    2008-01-01

    Full text: As a consequence of the highly nonuniform exposure conditions in the interventional radiology, a reliable estimation of the effective dose for occupationally exposed persons requires a number of dose measurements at various locations of the body. The nonuniform occupational exposure is mainly associated with the relatively short distance to the radiation source (the scattered radiation from the patient) and the attenuation of the scattered radiation by protective clothing and shielding. The staff who undertake these procedures may receive radiation doses approaching the dose limits suggested by International Commission on Radiological Protection (ICRP 1991) if there is a high patient workload, for extended period of time. According to the Croatian radiation protection regulations for the effective dose estimation it is mandatory to use one dosimeter placed at the left side of the chest under the protective apron. From the dosimeter reading (dosimeter is calibrated in term of H p (10)) the effective dose is estimated. If additional dosimeters are worn on different parts of the body, their results have to be recorded, but they are not used for effective dose estimations. In the University Hospital Zagreb the personnel performing interventional radiology procedures in addition to the dosimeter placed under the apron always wear another dosimeter placed on the apron at the neck or shoulder position. In this work, the results of recorded dosimetry measurements performed during the period of 10 years were analysed. Special attention was given to the evaluation of the effective dose. The results of only one dosimeter are compared with the results obtained with two dosimeters. In the later case the effective dose was evaluated using some proposed algorithms for double dosimetry. Since it is well known that the evaluation of effective dose from the reading (without any correction) of only one dosimeter placed under the apron usually underestimate the effective

  20. Provision of out-of-hours interventional radiology services in Scotland

    International Nuclear Information System (INIS)

    Zealley, I.A.; Gordon, T.J.; Robertson, I.; Moss, J.G.; Gillespie, I.N.

    2012-01-01

    Aim: To evaluate the availability of out-of-hours (OOH) interventional radiology (IR) services in Scotland and discuss implications for service redesign. Materials and methods: Data were gathered via a survey conducted by telephone/e-mail interview. The setting was hospitals in Scotland with acute medical and/or surgical beds. The interviewees were consultant interventional radiologists representing each of the 14 geographical Health Boards in Scotland. Results: Three of the 14 geographical Health Boards provided a formal, prospectively planned OOH IR service in at least one hospital. Fourteen of the 34 acute hospitals provided an in-hours IR service, which includes endovascular haemorrhage control. Eight of the 34 acute hospitals had formal, prospectively planned on-call IR arrangements, 12 had an ad-hoc service, and 20 transferred patients to other facilities. Thirty-eight of the 223 consultant radiologists in Scotland were able to perform endovascular haemorrhage control procedures: only 18 of these 38 (47%) were included in on-call rotas. A further 42 radiologists were able to perform nephrostomy and a further 61 were able to perform abscess drainage. Eighty-two radiologists did not perform any interventional procedures. Conclusions: The provision of OOH IR services in Scotland is limited and available resources, both skills and equipment, are being underutilized. These data will be used to inform a process of OOH IR service redesign in Scotland.

  1. Usefulness and Limitation of Manual Aspiration Immediately After Pneumothorax Complicating Interventional Radiological Procedures with the Transthoracic Approach

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko

    2006-01-01

    The goal of this study was to evaluate the efficacy of simple aspiration of air from the pleural space to prevent increased pneumothorax and avoid chest tube placement in cases of pneumothorax following interventional radiological procedures performed under computed tomography fluoroscopic guidance with the transthoracic percutaneous approach. While still on the scanner table, 102 cases underwent percutaneous manual aspiration of a moderate or large pneumothorax that had developed during mediastinal, lung, and transthoracic liver biopsies and ablations of lung and hepatic tumors (independent of symptoms). Air was aspirated from the pleural space by an 18- or 20-gauge intravenous catheter attached to a three-way stopcock and 20- or 50-mL syringe. We evaluated the management of each such case during and after manual aspiration. In 87 of the 102 patients (85.3%), the pneumothorax had resolved completely on follow-up chest radiographs without chest tube placement, but chest tube placement was required in 15 patients. Requirement of chest tube insertion significantly increased in parallel with the increased volume of aspirated air. When receiver-operating characteristic curves were applied retrospectively, the optimal cutoff level of aspirated air on which to base a decision to abandon manual aspiration alone and resort to chest tube placement was 670 mL. Percutaneous manual aspiration of the pneumothorax performed immediately after the procedure might prevent progressive pneumothorax and eliminate the need for chest tube placement. However, when the amount of aspirated air is large (such as more than 670 mL), chest tube placement should be considered

  2. Radiation field distribution within the room for three commonly-used interventional procedures

    International Nuclear Information System (INIS)

    Liu Changcai; Zhang Lin; Min Nan; Lu Feng; Li Quantai; Deng Daping; Chen Yue; Zhu Jianguo

    2014-01-01

    Objective: To detect the radiation field distribution within the room for three commonly-used interventional procedures, in order to provide basic data for the radiation protection and safe operation of staff involved in interventional radiology. Methods: The thermoluminescent dosemeters (TLDs) were placed in different points on the horizontal plane around the interventional table and the vertical plane where the staff often stayed. Based on the selected experimental conditions, the TLDs were grouped to be irradiated. After the experiment, the TLDs were measured in the laboratory to calculate the doses of radiation field. Results: Data obtained at the same position followed basically as cardiovascular intervention > cerebrovascular intervention > liver intervention. Intervention of same type at the same position followed as high-dose group > mid-dose group > low-dose group. These results were consistent with the useful beam doses, and proportional to the fluoroscopy time. A few data with exception were due to measurement error or experimental error. Conclusions: Cerebrovascular and liver interventional procedures resulted in the relatively low radiation doses. The radiation doses at the distance of more than 3 m can be negligible. For cardiovascular interventional procedure, with the decrease of the distance from the X-ray tube, the dose decreased. In the radiation field,the operator, the first assistant and second assistant would exposed to higher dose on the standing points while patients receive lower doses in the head and feet direction. (authors)

  3. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    Science.gov (United States)

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-01-09

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  4. Estimation of absorbed dose and its biological effects in subjects undergoing neuro interventional radiological procedures

    International Nuclear Information System (INIS)

    Basheerudeen, Safa Abdul Syed; Subramanian, Vinodhini; Venkatachalam, Perumal; Joseph, Santosh; Selvam, Paneer; Jose, M.T.; Annalakshmi, O.

    2016-01-01

    Radiological imaging has many applications due to its non-invasiveness, rapid diagnosis of life threatening diseases, and shorter hospital stay which benefit patients of all age groups. However, these procedures are complicated and time consuming, which use repeated imaging views and radiation, thereby increasing patient dose, and collective effective dose to the background at low doses. The effects of high dose radiation are well established. However, the effects of low dose exposure remain to be determined. Therefore, investigating the effect on medically exposed individuals is an alternative source to understand the low dose effects of radiation. The ESD (Entrance Surface Dose) was recorded using Lithium borate based TL dosimeters to measure the doses received by the head, neck and shoulder of the study subjects (n = 70) who underwent procedures like cerebral angiography, coiling, stenting and embolization

  5. The role of interventional radiology and imaging in pancreatic islet cell transplantation

    International Nuclear Information System (INIS)

    Dixon, S.; Tapping, C.R.; Walker, J.N.; Bratby, M.; Anthony, S.; Boardman, P.; Phillips-Hughes, J.; Uberoi, R.

    2012-01-01

    Pancreatic islet cell transplantation (PICT) is a novel treatment for patients with insulin-dependent diabetes who have inadequate glycaemic control or hypoglycaemic unawareness, and who suffer from the microvascular/macrovascular complications of diabetes despite aggressive medical management. Islet transplantation primarily aims to improve the quality of life for type 1 diabetic patients by achieving insulin independence, preventing hypoglycaemic episodes, and reversing hypoglycaemic unawareness. The islet cells for transplantation are extracted and purified from the pancreas of brain-stem dead, heart-beating donors. They are infused into the recipient's portal vein, where they engraft into the liver to release insulin in order to restore euglycaemia. Initial strategies using surgical access to the portal vein have been superseded by percutaneous access using interventional radiology techniques, which are relatively straightforward to perform. It is important to be vigilant during the procedure in order to prevent major complications, such as haemorrhage, which can be potentially life-threatening. In this article we review the history of islet cell transplantation, present an illustrated review of our experience with islet cell transplantation by describing the role of imaging and interventional radiology, and discuss current research into imaging techniques for monitoring graft function.

  6. The consent process in interventional radiology: the role of specialist nurses

    International Nuclear Information System (INIS)

    Davies, L.; Laasch, H.-U.; Wilbraham, L.; Marriott, A.; England, R.E.; Martin, D.F.

    2004-01-01

    AIMS: To evaluate the impact of patient education by specialist nurses on patients' understanding of interventional procedures, their anxiety levels and satisfaction with the given information. MATERIALS AND METHODS: Sixty patients attending the radiology department for gastrointestinal interventional procedures were interviewed. Patients were assessed using a combination of categorical and visual analogue scales. Parameters were assessed on admission and after additional information had been given by specialist nurses. After the procedure patients were asked to rate the quality of information given and their overall satisfaction. RESULTS: Four of the 60 patients were excluded due to a Mini Mental Test score of <7. Only 35 (62.5%) claimed to have been given information by the referring consultant. Fifty-three patients received additional information before formally giving consent, 50 (96.2%) from the specialist nurses. Patient anxiety before and after information did not significantly change (p=0.52), but there was significant improvement in levels of satisfaction (p=0.001) and perceived understanding (p<0.001). Patients rated overall quality of information at an average of 9.2/10 and overall satisfaction was high (median=9.1/10). CONCLUSION: The use of specialist nurses to educate patients greatly increases patient understanding. The process of informed consent is improved and patient satisfaction is increased

  7. The consent process in interventional radiology: the role of specialist nurses

    Energy Technology Data Exchange (ETDEWEB)

    Davies, L.; Laasch, H.-U.; Wilbraham, L.; Marriott, A.; England, R.E.; Martin, D.F. E-mail: derrick.martin@smtr.nhs.uk

    2004-03-01

    AIMS: To evaluate the impact of patient education by specialist nurses on patients' understanding of interventional procedures, their anxiety levels and satisfaction with the given information. MATERIALS AND METHODS: Sixty patients attending the radiology department for gastrointestinal interventional procedures were interviewed. Patients were assessed using a combination of categorical and visual analogue scales. Parameters were assessed on admission and after additional information had been given by specialist nurses. After the procedure patients were asked to rate the quality of information given and their overall satisfaction. RESULTS: Four of the 60 patients were excluded due to a Mini Mental Test score of <7. Only 35 (62.5%) claimed to have been given information by the referring consultant. Fifty-three patients received additional information before formally giving consent, 50 (96.2%) from the specialist nurses. Patient anxiety before and after information did not significantly change (p=0.52), but there was significant improvement in levels of satisfaction (p=0.001) and perceived understanding (p<0.001). Patients rated overall quality of information at an average of 9.2/10 and overall satisfaction was high (median=9.1/10). CONCLUSION: The use of specialist nurses to educate patients greatly increases patient understanding. The process of informed consent is improved and patient satisfaction is increased.

  8. A survey of interventional radiology awareness among final-year medical students in a European country.

    LENUS (Irish Health Repository)

    Leong, Sum

    2009-07-01

    Interventional radiology (IR) is a rapidly expanding specialty that is facing the challenges of turf wars and personnel shortages. Appropriate exposure of medical students to this field can be vital to recruitment of potential future trainees or referring physicians. The aim of this study was to determine the knowledge and views of final-year medical students in a single EU country regarding various aspects of IR. An electronic survey was sent via e-mail to all final-year medical students in a European country. The students were given a month to respond to the questionnaire. A total of 234 students of 675 (34.5%) replied to the survey. Of the respondents, 35% had previously completed an attachment to the radiology department. The majority of students (63%) thought their knowledge in radiology in general was poor. The percentage of students who correctly identified procedures performed by interventional radiologists was 69% for Hickman line insertion, 79% for fibroid embolization, and 67.5% for lower limb angioplasty. Sixty percent, 30%, and 47% thought that interventional radiologists perform cardiac angioplasties, perform arterial bypasses, and create AV fistulas, respectively. Forty-nine percent felt that interventional radiologists are surgically trained. Eighty-three percent of students were first made aware of angioplasty by a cardiologist. Thirty-one percent thought that interventional radiologists do ward rounds, 24% thought that interventional radiologists have admitting rights, and 26% felt that interventional radiologists run an outpatient practice. A significant number of students (76%) thought that the job prospects in IR are good or excellent but only 40.5% were willing to consider a career in IR. In conclusion, this study indicates that IR remains a nascent but attractive specialty to the majority of medical students. Further development of the existing informal undergraduate curriculum to address shortcomings will ensure that IR continues to attract

  9. A Survey of Interventional Radiology Awareness Among Final-Year Medical Students in a European Country

    International Nuclear Information System (INIS)

    Leong, Sum; Keeling, Aoife N.; Lee, Michael J.

    2009-01-01

    Interventional radiology (IR) is a rapidly expanding specialty that is facing the challenges of turf wars and personnel shortages. Appropriate exposure of medical students to this field can be vital to recruitment of potential future trainees or referring physicians. The aim of this study was to determine the knowledge and views of final-year medical students in a single EU country regarding various aspects of IR. An electronic survey was sent via e-mail to all final-year medical students in a European country. The students were given a month to respond to the questionnaire. A total of 234 students of 675 (34.5%) replied to the survey. Of the respondents, 35% had previously completed an attachment to the radiology department. The majority of students (63%) thought their knowledge in radiology in general was poor. The percentage of students who correctly identified procedures performed by interventional radiologists was 69% for Hickman line insertion, 79% for fibroid embolization, and 67.5% for lower limb angioplasty. Sixty percent, 30%, and 47% thought that interventional radiologists perform cardiac angioplasties, perform arterial bypasses, and create AV fistulas, respectively. Forty-nine percent felt that interventional radiologists are surgically trained. Eighty-three percent of students were first made aware of angioplasty by a cardiologist. Thirty-one percent thought that interventional radiologists do ward rounds, 24% thought that interventional radiologists have admitting rights, and 26% felt that interventional radiologists run an outpatient practice. A significant number of students (76%) thought that the job prospects in IR are good or excellent but only 40.5% were willing to consider a career in IR. In conclusion, this study indicates that IR remains a nascent but attractive specialty to the majority of medical students. Further development of the existing informal undergraduate curriculum to address shortcomings will ensure that IR continues to attract

  10. Microdialysis technique and interventional radiology

    International Nuclear Information System (INIS)

    An Xiao; Xiao Xiangsheng

    2007-01-01

    Basic research in interventional radiology, including transcatheter artery perfusion especially, is progressing slowly due to lack of proper method. Microdialysis technique, a kind of accurate sampling technique in vivo, may help to solve the problem. Just as its name implies, microdialysis means tiny dialysis with advantages of authenticity, exactness and less error. Furthermore it has been applied widely and should be received with great attention and popularity. (authors)

  11. Complementary roles of interventional radiology and therapeutic endoscopy in gastroenterology

    DEFF Research Database (Denmark)

    Ray, David M; Srinivasan, Indu; Tang, Shou-Jiang

    2017-01-01

    radiology have resulted in the paradigm shift in the management of these conditions. In this paper, we discuss the patient's work up, indications, and complementary roles of endoscopic and angiographic management in the settings of gastrointestinal bleeding, enteral feeding, cecostomy tube placement...... and luminal strictures. These conditions often require multidisciplinary approaches involving a team of interventional radiologists, gastroenterologists and surgeons. Further, the authors also aim to describe how the fields of interventional radiology and gastrointestinal endoscopy are overlapping...

  12. C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Nagaraja, Sanjoy; Byrne, James V.

    2010-01-01

    Flat detector computed tomography (FDCT) is an imaging tool that generates three-dimensional (3-D) volumes from data obtained during C-arm rotation using CT-like reconstruction algorithms. The technique is relatively new and, at current levels of performance, lags behind conventional CT in terms of image quality. However, the advantage of its availability in the interventional room has prompted neuro-radiologists to identify clinical settings where its role is uniquely beneficial. We performed a search of the online literature databases to identify studies reporting experience with FDCT in interventional neuro-radiology. The studies were systematically reviewed and their findings grouped according to specific clinical situation addressed. FDCT images allow detection of procedural complications, evaluation of low-radiopacity stents and assessment of endosaccular coil packing in intra-cranial aneurysms. Additional roles are 3-D angiography that provides an accurate depiction of vessel morphology with low concentrations of radiographic contrast media and a potential for perfusion imaging due to its dynamic scanning capability. A single scan combining soft tissue and angiographic examinations reduces radiation dose and examination time. Ongoing developments in flat detector technology and reconstruction algorithms are expected to further enhance its performance and increase this range of applications. FDCT images provide useful information in neuro-interventional setting. If current research confirms its potential for assessing cerebral haemodynamics by perfusion scanning, the combination would redefine it as an invaluable tool for interventional neuro-radiology procedures. This facility and its existing capabilities of parenchymal and angiographic imaging would also extend its use to the triage of acute stroke patients. (orig.)

  13. Analysis of dose to crystalline in Interventional radiology: a purpose of one case

    International Nuclear Information System (INIS)

    Carrera M, F.; Moreno R, F.; Velazquez M, F.; Manzano M, F.J.; Moreno S, T.

    1998-01-01

    The present work shows the dose values to crystalline for the personnel which works in interventional radiology procedures. It was took data of 436 studies with a total of 2,133.4 minutes in fluoroscopy and 19,563 images. It was showed dose values to crystalline in three situations: without blinding, with blinding of 0.25 and 0.50 mm Pb and by type of study: fluoroscopy, graphie and total. The dose means and ranges to patient for each of these studies also are detailed. (Author)

  14. Patient Dose Optimization in Fluoroscopically Guided Interventional Procedures. Final Report of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2010-01-01

    In recent years, many surgical procedures have increasingly been replaced by interventional procedures that guide catheters into the arteries under X ray fluoroscopic guidance to perform a variety of operations such as ballooning, embolization, implantation of stents etc. The radiation exposure to patients and staff in such procedures is much higher than in simple radiographic examinations like X ray of chest or abdomen such that radiation induced skin injuries to patients and eye lens opacities among workers have been reported in the 1990's and after. Interventional procedures have grown both in frequency and importance during the last decade. This Coordinated Research Project (CRP) and TECDOC were developed within the International Atomic Energy Agency's (IAEA) framework of statutory responsibility to provide for the worldwide application of the standards for the protection of people against exposure to ionizing radiation. The CRP took place between 2003 and 2005 in six countries, with a view of optimizing the radiation protection of patients undergoing interventional procedures. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation (BSS) issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the World Health Organization (WHO), the Pan American Health Organization (PAHO) and the Nuclear Energy Agency (NEA), among others, require the radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. In keeping with its responsibility on the application of standards, the IAEA programme on Radiological Protection of Patients encourages the reduction of patient doses. To facilitate this, it has issued specific advice on the application of the BSS in the field of radiology in Safety Reports Series No. 39 and the three volumes on Radiation

  15. Off label use of devices and drugs in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zvavanjanja, R.C., E-mail: Rodrick.Zvavanjanja@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool (United Kingdom); Odetoyinbo, T.O.; Rowlands, P.C.; Healey, A.; Abdelsalam, H.; Powell, S.; Evans, J.C.; Hughes, M.L.; Gould, D.A.; McWilliams, R.G. [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2012-03-15

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein{sup Copyright-Sign} (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  16. Off label use of devices and drugs in interventional radiology

    International Nuclear Information System (INIS)

    Zvavanjanja, R.C.; Odetoyinbo, T.O.; Rowlands, P.C.; Healey, A.; Abdelsalam, H.; Powell, S.; Evans, J.C.; Hughes, M.L.; Gould, D.A.; McWilliams, R.G.

    2012-01-01

    Aim: To establish how often off-label device and drug use occurs in interventional radiology (IR) in a UK tertiary referral hospital and consider the wider implications for the interventional radiologist. Materials and methods: Prospective data were collected during interventional procedures for 1 working week in a university hospital. Out-of-hours procedures and procedures outside the department were excluded. Operators were asked to record the drugs and devices used, the indication, and method of use. The instructions for use/summary of product characteristics were then studied for each device/drug used to assess if the use was on or off-label. Results: During the study period 52 cases were performed and data were available on 26 cases (50%). In 22 of the 26 cases (84%) there was evidence of off-label use of devices or drugs. Off-label use of drugs included treatment of venous malformations with Fibrovein © (sodium tetradecyl sulphate), which is licensed for the treatment of varicose veins in the leg, and intra-arterial injection of heparin, which is licensed for intravenous and subcutaneous use. Off-label device use included placing vascular sheaths in the urinary tract, using angiographic catheters to guide wires in the urinary tract, using sheaths for thrombosuction, reshaping of the tip of most guidewires, and using angioplasty balloons to dislodge the arterial plug at fistula thrombectomy. Conclusion: Off-label device and drugs use is common in a UK tertiary hospital IR department and literature suggests this is common in the wider IR community. There are important clinical and legal implications for off-label use for patients and physicians.

  17. Radiation protection in interventional radiology; Strahlenschutz in der interventionellen Radiologie

    Energy Technology Data Exchange (ETDEWEB)

    Adamus, R.; Loose, R.; Galster, M. [Klinikum Nuernberg Nord, Institut fuer Diagnostische und Interventionelle Radiologie, Nuernberg (Germany); Wucherer, M. [Klinikum Nuernberg Nord, Institut fuer Medizinische Physik, Nuernberg (Germany); Uder, M. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Radiologie, Erlangen (Germany)

    2016-03-15

    The application of ionizing radiation in medicine seems to be a safe procedure for patients as well as for occupational exposition to personnel. The developments in interventional radiology with fluoroscopy and dose-intensive interventions require intensified radiation protection. It is recommended that all available tools should be used for this purpose. Besides the options for instruments, x-ray protection at the intervention table must be intensively practiced with lead aprons and mounted lead glass. A special focus on eye protection to prevent cataracts is also recommended. The development of cataracts might no longer be deterministic, as confirmed by new data; therefore, the International Commission on Radiological Protection (ICRP) has lowered the threshold dose value for eyes from 150 mSv/year to 20 mSv/year. Measurements show that the new values can be achieved by applying all X-ray protection measures plus lead-containing eyeglasses. (orig.) [German] Die Anwendung ionisierender Strahlung in der Medizin scheint sowohl fuer Patienten als auch fuer beruflich exponierte Personen sicher zu sein. Die interventionellen Entwicklungen der letzten Jahre mit sehr durchleuchtungs- und dosisintensiven Eingriffen erfordern allerdings eine Intensivierung des Strahlenschutzes. Es empfiehlt sich, die zur Verfuegung stehenden Moeglichkeiten auszuschoepfen. Neben den Geraeteoptionen muss der Strahlenschutz am Eingriffstisch durch Bleilamellenaufstecker und montiertes Bleiglas intensiv betrieben werden. Besonderen Fokus muss auf den Schutz der Augen zur Kataraktvermeidung gelegt werden. Da dessen Ausbildung nach neuen Erkenntnissen moeglicherweise nicht mehr deterministisch zu sehen ist, hat die Internationale Strahlenschutzkommission (IRCP) den Grenzwert von 150 auf 20 Mikrosievert (mSv)/Jahr erniedrigt. Messungen belegen, dass unter Einhaltung aller Strahlenschutzmassnahmen plus Bleiglasbrille dieser einzuhalten ist. (orig.)

  18. Evidence-based radiology: a new approach to evaluate the clinical practice of radiology

    International Nuclear Information System (INIS)

    Puig, S.; Felder-Puig, R.

    2006-01-01

    Over the last several years, the concept and methodology of evidence-based medicine (EBM) have received significant attention in the scientific community. However, compared to therapeutic medical disciplines, EBM-based radiological publications are still underrepresented. This article summarizes the principles of EBM and discusses the possibilities of their application in radiology. The presented topics include the critical appraisal of studies on the basis on EBM principles, the explanation of EBM-relevant statistical outcome parameters (e.g., ''likelihood ratio'' for diagnostic and ''number needed to treat'' for interventional procedures), as well as the problems facing evidence-based radiology. Evidence-based evaluation of radiological procedures does not only address aspects of cost-effectiveness, but is also particularly helpful in identifying patient-specific usefulness. Therefore it should become an integral part of radiologist training. (orig.)

  19. Analysis of occupational doses in interventional radiology and cardiology installations

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Ten, J.I.; Guibelalde, E.; Fernandez, J.M.

    1997-01-01

    The relationship between patient dose (PD) and occupational dose (OD) is not easily predictable in interventional radiology installations due to a large number of factors which can modify the occupational risk (OR). In the present work an analysis is made of the four main aspects which influence OR, namely, x-ray beam used, radiation protection (RP) tools available (aprons, thyroid protectors, gloves, screens, etc) and their regular use, type and number of procedures performed (diagnostic or therapeutic, complexity level, etc), and RP training level of the specialists. High filtration x-ray beams can entail a decrease of 20% in OD. A regular use of ceiling mounted faceplates can involve dose savings up to 65%. Mean values of dose per procedure for interventional radiologists are something greater (about 15%) than those recorded for cardiologists, except for the dosimeters placed on left forearm and shoulder. The ratio between OD and PD range around 100 μSv/1,000 cGy.cm 2 . The influence of the staff RP training level on OD is difficult to assess. In the IC Service from the Madrid San Carlos University Hospital (SCUH), PD have been reduced in above 30% and OD in a factor of 3, after running some training programmes. (author)

  20. Interventional radiology - Health at work references Nr 130

    International Nuclear Information System (INIS)

    Machacek, C.; Menechal, P.; Megnigbeto, C.; Aubert, B.; Rehel, J.L.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Donnarieix, D.; Gambini, D.; Guerin, C.; Marande, J.L.; Marelle, P.; Pierrat, N.

    2012-06-01

    After having noticed that interventional radiology is used in most of medical and surgical specialities, and indicated the factors influencing operator exposure, this sheet indicates the different types of personnel concerned by these practices, the hazards and risks associated with exposure to direct or scattered radiation, the way risk is assessed and exposure levels are determined (definition of controlled and surveyed areas, personnel classification, selection of a dosimetric control method), how a risk management strategy is defined and implemented (risk reduction methods, technical measures for the installation and for personnel, information and training actions, prevention measures, procedures in case of incident or dysfunction), how medical survey is performed for the personnel, in case of pregnancy, and by using a medical file and performing a post-professional follow-up, and by taking on anomalies and incidents. It also describes how risk management is to be assessed, and mentions some other risks

  1. Benefits of an automatic patient dose registry system for interventional radiology and cardiology at five hospitals of the Madrid area

    International Nuclear Information System (INIS)

    Fernandez-Soto, J.M.; Vano, E.; Sanchez, R.M.; Ten, J.I.; Espana, M.; Pifarre, X.

    2015-01-01

    The purpose of this article is to present the results of connecting the interventional radiology and cardiology laboratories of five university hospitals to a unique server using an automatic patient dose registry system (Dose On Line for Interventional Radiology, DOLIR) developed in-house, and to evaluate its feasibility more than a year after its introduction. The system receives and stores demographic and dosimetric parameters included in the MPPS DICOM objects sent by the modalities to a database. A web service provides a graphical interface to analyse the information received. During 2013, the system processed 10 788 procedures (6874 cardiac, 2906 vascular and 1008 neuro interventional). The percentages of patients requiring clinical follow-up due to potential tissue reactions before and after the use of DOLIR are presented. The system allowed users to verify in real-time, if diagnostic (or interventional) reference levels are fulfilled. (authors)

  2. Radiation Protection Knowledge, Attitude, and Practice (KAP) in Interventional Radiology.

    Science.gov (United States)

    Shabani, Fatemeh; Hasanzadeh, Hadi; Emadi, Alireza; Mirmohammadkhani, Majid; Bitarafan-Rajabi, Ahmad; Abedelahi, Ali; Bokharaeian, Mitra; Masoumi, Hamed; Seifi, Danial; Khani, Tahereh; Sanchooli, Mohamad; Moshfegh, Shima; Ziari, Abbas

    2018-03-01

    Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP) level of radiation protection (RP) among interventional radiology staff in Iranian health care centers across the country. We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician). The questionnaire was divided into three sections to assess KAP regarding RP. Significant differences exist in RP KAP mean scores based on educational age (p 0.050). We found a significant difference between RP KAP mean scores and different regions (p < 0.050). Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments.

  3. Radiation Protection Knowledge, Attitude, and Practice (KAP in Interventional Radiology

    Directory of Open Access Journals (Sweden)

    Fatemeh Shabani

    2018-03-01

    Full Text Available Objectives: Due to increasing cardiac disease and its mortality rate, the frequency of cardiac imaging has grown and, as a result, interventional cardiologists potentially receive high radiation doses in cardiac examinations. This study aimed to assess the knowledge, attitude, and practice (KAP level of radiation protection (RP among interventional radiology staff in Iranian health care centers across the country. Methods: We used a validated questionnaire survey consisting of 30 multiple-choice questions to perform a cross-sectional study. Participants were healthcare personnel working professionally with radiation at different levels (i.e., secretary, radiology technologists, nurse, and physician. The questionnaire was divided into three sections to assess KAP regarding RP. Results: Significant differences exist in RP KAP mean scores based on educational age (p 0.050. We found a significant difference between RP KAP mean scores and different regions (p < 0.050. Conclusions: Educational and practice age, sex, type of hospital, and geographical region affect he KAP of interventional radiology staff regarding RP. Since many of the subjective radiation harms for both medical team and patients, this can be easily controlled and prevented; a checkup for personnel of interventional radiology departments, considering samples from different parts of the country with different levels of education, continuous training, and practical courses may help map the status of KAP. The results of this study may also help authorized health physics officers design strategic plans to enhance the quality of such services in radiation departments.

  4. Interventional radiology simulation and measurement of patient doses; Simulacion en radiologia intervencionista y medida de dosis a pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz Lablanca, M. d.; Diaz Romero, F.; Hernandez Armas, J.

    2011-07-01

    In this paper we propose a method of work to calculate the effective dose in any interventional radiology procedure using an Alderson Rando anthropomorphic phantom and dosimeters TLD 100 chip. We applied this method in the case of biliary drainage and allowed us to establish the dose value corresponding reference in the Hospital Universitario de Canarias (HUC).

  5. Radiologic intervention: patient anxiety, fear of pain, understanding of the procedure and satisfaction with the medication-a prospective study

    International Nuclear Information System (INIS)

    Kim, Tae Hoon

    2006-01-01

    I wanted to prospectively assess patients' anxiety, their understanding of the procedure being performed, the perception of the pain level and the satisfaction with the administered medication for interventional procedures. I investigated 78 patients before and after they underwent 93 interventional procedures. The patients responded to a series of questions by using a visual analogue scale (VAS). Two different procedures were performed on 15 patients at different times. Based on the patient's body weight, a combination of sedative and analgesic was intravenously administered. The mean anxiety VAS score for the interventional procedures was about 5.3. The mean anxiety score of the experienced patients was about 3.8 and that of the inexperienced patients was about 5.5 (ρ < .001). The mean score for the understanding of the procedure, which was recorded both before and after the procedure, was about 4.1 and 7.1, respectively. The mean scores for the understanding of the procedure were about 7.0 in the experienced patients and about 3.6 in the inexperienced patients (ρ < .001). The anticipated level of pain recorded before the procedure was about 5.2 and the level of pain during the procedure was 2.9, and the latter was recorded after the procedure (ρ < .001). The level of satisfaction with the medication provided during the procedure was about 8.0 on the VAS score. The patients had a moderate amount of anxiety about the interventional procedures. Most patients had a high level of satisfaction with the medication despite the amount of pain they experienced during the procedure. The patients who were experienced with a procedure tended to have less anxiety and anticipated pain, and they had a greater understanding of the procedure

  6. Is Your Interventional Radiology Service Ready for SARS?: The Singapore Experience

    International Nuclear Information System (INIS)

    Lau, Te-Neng; Teo, Ngee; Tay, Kiang-Hiong; Chan, Ling-Ling; Wong, Daniel; Lim, Winston E.H.; Tan, Bien-Soo

    2003-01-01

    The recent epidemic of severe acute respiratory syndrome caught many by surprise. Hitherto, infection control has not been in the forefront of radiological practice. Many interventional radiology (IR) services are therefore not equipped to deal with such a disease. In this review, we share our experience from the interventional radiologist's perspective, report on the acute measures instituted within our departments and explore the long-term effects of such a disease on the practice of IR

  7. Should there be greater exposure to interventional radiology in the undergraduate curriculum?

    Directory of Open Access Journals (Sweden)

    Ojha U

    2017-12-01

    Full Text Available Utkarsh Ojha,1 Raihan Mohammed,2 Sayinthen Vivekanantham3 1Faculty of Medicine, Imperial College London, London, 2Department of Medicine, University of Cambridge, Cambridge, 3University of Aberdeen, Aberdeen, UK Abstract: Medical imaging has been one of the most revolutionary innovations in medicine. Today, as health care professionals shift their focus toward more sophisticated technology and minimally invasive procedures, interventional radiology (IR has become a rapidly expanding specialty. Despite these advances, there is a lack of doctors specializing in this field. A growing body of evidence suggests that the low number of applicants for posts may be due to poor exposure to the specialty at medical school. In this article, we outline the importance of IR in today’s health care system. Next, we evaluate the evidence that there is a lack of knowledge of IR not only among medical students in the UK but globally. We further discuss how a more effective incorporation of IR in the undergraduate curriculum can enhance medical students’ interest in the field and subsequently increase the number of doctors specializing in IR. Finally, we suggest alternative strategies to gauge medical students’ interest in IR, including teaching via e-learning and virtual reality. Keywords: interventional radiology, diagnostic imaging, innovation, medical education, e-learning, virtual reality

  8. Sedation for pediatric radiological procedures: analysis of potential causes of sedation failure and paradoxical reactions

    International Nuclear Information System (INIS)

    Karian, V.E.; Burrows, P.E.; Connor, L.; Zurakowski, D.; Mason, K.P.

    1999-01-01

    Background. Sedation for diagnostic imaging and interventional radiologic procedures in pediatrics has greatly increased over the past decade. With appropriate patient selection and monitoring, serious adverse effects are infrequent, but failure to sedate and paradoxical reactions do occur. Objective. The purpose of this study was to determine, among patients undergoing sedation for radiologic procedures, the incidence of sedation failure and paradoxical reaction to pentobarbital and to identify potentially correctable causes. Materials and methods. Records of 1665 patients who were sedated in the radiology department from 1 November 1997 to 1 July 1998 were reviewed. Patients failing sedation or experiencing paradoxical reaction were compared with respect to sex, age group, diagnosis, scan type, time of day, NPO status, use of IV contrast and type of sedation agent using the Fisher exact test, Pearson chi-square, analysis of variance (ANOVA), the Student t-test, and logistic regression. Results. Data analysis revealed a sedation failure rate of 1 % and paradoxical reaction rate of 1.2 %. Stepwise multiple logistic regression revealed that the only significant independent multivariate predictor of failure was the need for the administration of a combination of pentobarbital, fentanyl, and midazolam IV. Conclusion. The low rate of sedation failure and paradoxical reactions to pentobarbital was near optimal and probably cannot be improved with the currently available sedatives. (orig.)

  9. Sedation for pediatric radiological procedures: analysis of potential causes of sedation failure and paradoxical reactions

    Energy Technology Data Exchange (ETDEWEB)

    Karian, V.E.; Burrows, P.E.; Connor, L. [Dept. of Radiology, Children' s Hospital, Boston, MA (United States); Zurakowski, D. [Dept. of Biostatistics, Children' s Hospital, Boston, MA (United States); Mason, K.P. [Dept. of Anesthesiology, Children' s Hospital, Boston, MA (United States)

    1999-11-01

    Background. Sedation for diagnostic imaging and interventional radiologic procedures in pediatrics has greatly increased over the past decade. With appropriate patient selection and monitoring, serious adverse effects are infrequent, but failure to sedate and paradoxical reactions do occur. Objective. The purpose of this study was to determine, among patients undergoing sedation for radiologic procedures, the incidence of sedation failure and paradoxical reaction to pentobarbital and to identify potentially correctable causes. Materials and methods. Records of 1665 patients who were sedated in the radiology department from 1 November 1997 to 1 July 1998 were reviewed. Patients failing sedation or experiencing paradoxical reaction were compared with respect to sex, age group, diagnosis, scan type, time of day, NPO status, use of IV contrast and type of sedation agent using the Fisher exact test, Pearson chi-square, analysis of variance (ANOVA), the Student t-test, and logistic regression. Results. Data analysis revealed a sedation failure rate of 1 % and paradoxical reaction rate of 1.2 %. Stepwise multiple logistic regression revealed that the only significant independent multivariate predictor of failure was the need for the administration of a combination of pentobarbital, fentanyl, and midazolam IV. Conclusion. The low rate of sedation failure and paradoxical reactions to pentobarbital was near optimal and probably cannot be improved with the currently available sedatives. (orig.)

  10. Dosimetric studies of the eye lens using a new dosemeter – Surveys in interventional radiology departments

    International Nuclear Information System (INIS)

    Pirchio, R.; Sánchez, H.; Domazet, W.

    2014-01-01

    During interventional radiology (IR) and cardiology (IC) procedures, medical staff can receive high doses to their eye lenses. The Retrospective Evaluation of Lens Injuries and Dose study organized in Argentina in 2010 found incipient opacity in 50% of IC physicians and 41% of IC technicians/nurses. These results, added to the recommendations of the International Commission on Radiological Protection, which lowered their former occupational equivalent dose limit for the lens, led us to assess the eye lens dose, Hp(3), during interventional procedures. To this end, a new dosemeter was designed and calibrated at the National Atomic Energy Commission of Argentina to evaluate Hp(3). Personal dose equivalent (Hp(10)), and Hp(3) were assessed for 3 months in two IC and IR departments. An Alderson phantom was used to simulate monthly exposures of five occupational staff members. Hp(3) and Hp(10) were obtained monthly for 14 occupational staff members exposed to 121 IR and IC procedures. We concluded that the annual effective dose and Hp(3) were lower than 0.3 and 10 mSv, respectively and the average cumulative Hp(3) for working life was lower than 400 and 200 mSv for physicians and technicians/scrub nurse, respectively. An occupational annual dose constraint of 0.3 mSv was calculated. - Highlights: • An eye lens dosimeters was designed at the Personal Dosimetry Laboratory of CNEA. • A successful dosimetric survey in two interventional departments was done. • The annual effective dose and the annual eye lens dose are lower than the ICRP dose thresholds. • In order to reduce doses actions should be promoted to maximize radiation protection

  11. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  12. Changes in the American Interventional Radiology Literature: Comparison over a 10-Year Time Period

    International Nuclear Information System (INIS)

    Ray, Charles E.; Gupta, Rajan; Blackwell, John

    2006-01-01

    Purpose. To determine the changes that occurred regarding interventional radiologic research in the major American radiology journals between 1992-1993 and 2002-2003. Methods. Articles published in three major American radiology journals (Journal of Vascular and Interventional Radiology, American Journal of Roentgenology, and Radiology) during two distinct 24-month time periods (1992-1993 and 2002-2003) were evaluated. All articles judged to be pertinent to the interventional radiologic community were included. Investigations included in journal subheadings other than 'interventional' or 'vascular radiology' were included if the emphasis of the article was on a vascular imaging modality or peripheral intervention. Exclusions included: case reports, technical reports, letters to the editor, breast interventions, and primary neurointerventions. Data were collected regarding the affiliations of the primary author (nationality, hospital type, department); primary category of interest of the investigation; funding information; and study design variables. Two-by-two chi-squared statistical analyses were performed comparing the variables from the early and late data sets. Results. A total of 405 articles met the inclusion criteria for the early data set (1992-1993); 488 articles met the inclusion criteria for the late data set (2002-2003). Variables that demonstrated a statistically significant decrease from the early data set to the late data set included: articles in which the primary author was from a department of radiology (91.1% vs. 86.3%; p < 0.025); articles written by a primary author who was American (69.4% vs. 44.6%; p < 0.001); and articles with a primary category of investigation that had a nonvascular intervention focus (22.7% vs. 11.9%; p < 0.001). Variables that demonstrated a statistically significant increase from the early data set to the late data set included primary authors from Western Europe (18.0% vs. 30.1%; p < 0.001) and Asia (6.6% vs. 18.4%; p

  13. Prostate embolization: A new acting field of interventional radiology

    International Nuclear Information System (INIS)

    Kisilevzky, N.; García Mónaco, R.; Peralta, O.; Rabelino, M.; Rosales Arroba, R.; Rodriguez, P.; Ocantos, J.; Martínez, P.F.; Damia, O.

    2014-01-01

    Purposes: To present the initial experience with prostatic embolization as an alternative treatment for benign prostatic hyperplasia (BPH) from a technical perspective to establish the contribution provided by diagnostic imaging. Materials and methods: Sixteen patients with lower urinary tract symptoms due to benign prostatic hyperplasia underwent prostatic embolization. All patients were evaluated with specific questionnaires to determine the severity of symptoms, impact on quality of life and erectile function, ultrasound and MRI of the pelvis, urinary flowmetry and PSA before and 30 days after the procedure. Results: Embolization was successful in all patients; in 10 cases the procedure was performed bilaterally and in six, only one side was embolized. The average time for completion of the procedure was 82 minutes and the average fluoroscopy time was 38.5 minutes. All procedures were performed on an outpatient basis with an average hospital stay of 6.4 hours. The mean contrast medium used was 175 ml. At 30 days there was a mean reduction on prostate volume of 21%. Clinical improvement was characterized by a mean 8-point improvement on IPSS, 2 points on QOL and 4 points on IIEF. The uroflowmetry improved 39% and PSA dropped 26%. No major complications that implied unscheduled hospitalization or performing additional surgical procedures were seen. Minor adverse events were verified in 9 patients. Conclusion: The initial results of prostatic embolization as an alternative treatment for BPH indicate that it is a safe and effective procedure to be consolidated as a new field of action of interventional radiology. (authors) [es

  14. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbrenner, R; Kolli, KP; Taylor, A; Kohi, M; Fidelman, N; LaBerge, J; Kerlan, R; Gould, R [University of California, San Francisco, San Francisco, CA (United States)

    2014-06-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav

  15. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    International Nuclear Information System (INIS)

    Kohlbrenner, R; Kolli, KP; Taylor, A; Kohi, M; Fidelman, N; LaBerge, J; Kerlan, R; Gould, R

    2014-01-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav

  16. Development of a calibration methodology for instruments used to interventional radiology quality control

    International Nuclear Information System (INIS)

    Miranda, Jurema Aparecida de

    2009-01-01

    Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well established rules to determine the doses and to make the dosimetry in fluoroscopic beams. There is great interest in this study, in relation to the beam quality, the half-value-layer, and others parameters. In this work a Medicor Neo Diagnomax clinical X ray generator, fluoroscopy mode, was used to develop a calibration methodology for instruments used in interventional radiology quality control. One plane parallel ionization chamber PTW was used as monitor. The ionization chambers recommended for fluoroscopy measurements had been evaluated and calibrated in relation to the IPEN Calibration Laboratory reference ionization chamber. The RQR3, RQR5 and RQR7 radiation qualities and the specific ones for fluoroscopy, RQC3, RQC5 and RQC7, were established following the norm IEC 61267. All beams characteristics were determined. Ionization chambers positioning system and the acrylic phantoms to the entrance and exit doses determination were developed and constructed. The results obtained show air kerma rates of 4.5x10 -3 , 1.2x10 -2 and 1.9x10 -2 Gy/min for RQC3, RQC5 and RQC7 respectively. Tests with and without the collimation just after the monitor chamber, were carried out and the results showed a difference of +5.5%, +0.6% e + 0.8%, confirming the importance of the collimation use in these interventionist procedures. (author)

  17. Estimated collective effective dose to the population from radiological examinations in Slovenia

    Science.gov (United States)

    Zontar, Dejan; Zdesar, Urban; Kuhelj, Dimitrij; Pekarovic, Dean; Skrk, Damijan

    2015-01-01

    Background The aim of the study was to systematically evaluate population exposure from diagnostic and interventional radiological procedures in Slovenia. Methods The study was conducted in scope of the “Dose Datamed 2” project. A standard methodology based on 20 selected radiological procedures was adopted. Frequencies of the procedures were determined via questionnaires that were sent to all providers of radiological procedures while data about patient exposure per procedure were collected from existing databases. Collective effective dose to the population and effective dose per capita were estimated from the collected data (DLP for CT, MGD for mammography and DAP for other procedures) using dose conversion factors. Results The total collective effective dose to the population from radiological in 2011 was estimated to 1300 manSv and an effective dose per capita to 0.6 mSv of which approximately 2/3 are due to CT procedures. Conclusions The first systematic study of population exposure to ionising radiation from radiological procedures in Slovenia was performed. The results show that the exposure in Slovenia is under the European average. It confirmed large contributions of computed tomography and interventional procedures, identifying them as the areas that deserve special attention when it comes to justification and optimisation. PMID:25810709

  18. Improving patient follow-up in interventional radiology and radiation-based acts. To reduce the risk of deterministic effects

    International Nuclear Information System (INIS)

    Etard, Cecile; Aubert, Bernard; Lafont, Marielle; Mougniot, Sandrine; Rousse, Carole; Bey, Eric; Cassagnes, Lucie; Guersen, Joel; Ducou Le Pointe, Hubert; Elhadad, Simon; Georges, Jean-Louis; Nonent, Michel; Paisant-Thouveny, Francine; Salvat, Cecile; Vidal, Vincent; Chauvet, Bruno; Riu, Jean-Luc; Voix, Fabien; Bar, Olivier; Le Du, Dominique; Maccia, Carlo; Lacombe, Pascal; Mertz, Luc; Valery, Charles

    2014-04-01

    After having presented an example of adverse reaction to interventional radiology (a case of a iatrogenic radiodermatitis), this report first presents the context which creates a risk situation. It describes risks related to the use of ionizing radiations, identifies risk factors and how to make procedures safer, and indicates actions aimed at reducing risks (in a preventive way, in recovery, by attenuation)

  19. Radiation dose to patients from the coronary angiography and percutaneous transluminal coronary angioplasty in interventional radiology procedures

    International Nuclear Information System (INIS)

    Zheng, Jun-Zheng; Bai, Mei; Liu, Bin

    2008-01-01

    Full text: Objective: To survey and assess radiation dose to patients from coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) in Beijing Xuanwu Hospital of Capital University of Medical Sciences. Methods: The dose-area product (DAP) values to the patient and cumulative dose (CD) were recorded from 84 coronary angiographies and 51 percutaneous transluminal coronary angioplasty. A Monte-Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Organ doses were also measured by thermoluminescent dosimeters (TLD) using a human-shaped phantom to compare the calculated organ dose from DAP. Results: The difference between the organ doses measured by TLDs and those from PCXMC software (P>0.05) were tolerable. The DAP value ranged from 7611∼60538 mGy·cm 2 for CA and 16423∼161973 mGy·cm 2 for PTCA. The effective dose for all procedures was determined to be in the range of 1.1∼6.9 mSv for CA and 2.3∼20.1 mSv for PTCA. CD ranged from 120.0 to 1016.0 mGy for CA and 287 to 2883 mGy for PTCA. Conversion factors between effective dose and DAP were 0.114∼0.139 mSv·Gy - 1·cm -2 for CA and 0.124∼0.142 mSv·Gy -1 ·cm -2 for PTCA; Conversion factors between organ dose and CD were derived for CA and PTCA, respectively. Conclusions: DAP and CD can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. Using this method can provide important information of patient absorbed dose and enhance the radiation protection of patient in interventional radiology procedures. (author)

  20. Postoperative radiology

    International Nuclear Information System (INIS)

    Burhenne, H.J.

    1989-01-01

    This paper reports on the importance of postoperative radiology. Most surgical procedures on the alimentary tract are successful, but postoperative complications remain a common occurrence. The radiologist must be familiar with a large variety of possible surgical complications, because it is this specialty that is most commonly called on to render a definitive diagnosis. The decision for reoperation, for instance, is usually based on results from radiologic imaging techniques. These now include ultrasonography, CT scanning, needle biopsy, and interventional techniques in addition to contrast studies and nuclear medicine investigation

  1. Maximum skin dose assessment in interventional cardiology: large area detectors and calculation methods

    International Nuclear Information System (INIS)

    Quail, E.; Petersol, A.

    2002-01-01

    Advances in imaging technology have facilitated the development of increasingly complex radiological procedures for interventional radiology. Such interventional procedures can involve significant patient exposure, although often represent alternatives to more hazardous surgery or are the sole method for treatment. Interventional radiology is already an established part of mainstream medicine and is likely to expand further with the continuing development and adoption of new procedures. Between all medical exposures, interventional radiology is first of the list of the more expansive radiological practice in terms of effective dose per examination with a mean value of 20 mSv. Currently interventional radiology contribute 4% to the annual collective dose, in spite of contributing to total annual frequency only 0.3% but considering the perspectives of this method can be expected a large expansion of this value. In IR procedures the potential for deterministic effects on the skin is a risk to be taken into account together with stochastic long term risk. Indeed, the International Commission on Radiological Protection (ICRP) in its publication No 85, affirms that the patient dose of priority concern is the absorbed dose in the area of skin that receives the maximum dose during an interventional procedure. For the mentioned reasons, in IR it is important to give to practitioners information on the dose received by the skin of the patient during the procedure. In this paper maximum local skin dose (MSD) is called the absorbed dose in the area of skin receiving the maximum dose during an interventional procedure

  2. On-field evaluation of operator lens protective devices in interventional radiology

    International Nuclear Information System (INIS)

    Strocchi, S.; Chiaravalli, A.; Veronese, I.; Novario, R.

    2016-01-01

    The recent publication of the Euratom Directive 2013/59, adopting the reduction of eye lens dose limits from 150 to 20 mSv y"-"1, calls for the development of new tools and methodologies for evaluating the eye lens dose absorbed by the medical staff involved in interventional radiology practices. Moreover, the effectiveness of the protective devices, like leaded glasses, which can be employed for radiation protection purposes, must be tested under typical exposure scenarios. In this work, eye lens dose measurements were carried out on an anthropomorphic phantom simulating a physician bound to perform standard interventional neuroradiology angiographic procedures. The correlation between eye lens doses, in terms of Hp(0.07), and the equivalent dose [again in terms of Hp(0.07)] monthly measured with thermoluminescent dosemeters placed above the lead apron at the chest level was studied, in the presence and in the absence of different types of leaded glasses. (authors)

  3. Paediatric Interventional Uroradiology

    International Nuclear Information System (INIS)

    Barnacle, Alex M.; Wilkinson, A. Graham; Roebuck, Derek J.

    2011-01-01

    Paediatric interventional uroradiology lies at the intersection of the disciplines of paediatric interventional radiology and paediatric endourology. Interdisciplinary collaboration has led to the development of new techniques and refinement of procedures adopted from adult practice. This article reviews the major procedures used in paediatric interventional uroradiology, with emphasis on nephrostomy, percutaneous nephrolithotomy, balloon-burst pyeloplasty, and antegrade ureteric stenting.

  4. Radiologically assisted percutaneous gastrostomy or enterostomy. A retrospective analysis of 90 procedures

    International Nuclear Information System (INIS)

    Mildenberger, P.; Oberholzer, K.; Kauczor, H.U.; Dueber, C.; Kurz, S.; Schild, H.; Thelen, M.

    1996-01-01

    To analyse retrospectively the indications, technique and results of radiologically induced gastrostomies or enterostomies. Radiologically assisted gastrostomies or enterostomies were induced in 90 patients, mostly with high grade obstructions due to head and neck tumours or oesophageal tumours. 19/90 patients had had previous resection of the oesophagus or gastric operations. A catheter was successfully introduced in all patients. In 11/90 patients this was followed by a two-stage procedure. In 16/90 patients puncture was performed under CT control because of some anatomical peculiarity. Serious complication occurred in 9/90 patients but in only one was surgery necessary. There were no deaths resulting from the procedure but mortality after 30 days was 6.7%. Radiologically assisted gastrostomies or enterostomies are a reliable and effective form of treatment even amongst difficult patients. The results and complications are comparable to those from endoscopic procedures. (orig.) [de

  5. An audit of diagnostic reference levels in interventional cardiology and radiology: Are there differences between academic and non-academic centres?

    International Nuclear Information System (INIS)

    Samara, E. T.; Aroua, A.; De palma, R.; Stauffer, J. C.; Schmidt, S.; Trueb, P. R.; Stuessi, A.; Treier, R.; Bochud, F.; Verdun, F. R.

    2012-01-01

    A wide variation in patient exposure has been observed in interventional radiology and cardiology. The purpose of this study was to investigate the patient dose from fluoroscopy-guided procedures performed in non-academic centres when compared with academic centres. Four procedures (coronary angiography, percutaneous coronary intervention, angiography of the lower limbs and percutaneous transluminal angioplasty of the lower limbs) were evaluated. Data on the dose-area product, fluoroscopy time and number of images for 1000 procedures were obtained from 23 non-academic centres and compared with data from 5 academic centres. No differences were found for cardiology procedures performed in non-academic centres versus academic ones. However, significantly lower doses were delivered to patients for procedures of the lower limbs when they were performed in non-academic centres. This may be due to more complex procedures performed in the academic centres. Comparison between the centres showed a great variation in the patient dose for these lower limb procedures. (authors)

  6. In the Lead Again Horizontal-Ellipsis [Journal of Cardiovascular and Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Ingolstadt Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2013-10-15

    The 2013 ISI journal rankings are out and it is my pleasure to inform our readership that CVIR ranks 43/120 (2012: 46/118) journals in the field of radiology. The 2013 impact factor further improved to 2.138 (2012: 2.093). This means that Cardiovascular and Interventional Radiology again continues to be the highest ranked journal dedicated to the field of interventional radiology in 2013.This is mainly due to the great support we achieve by you as authors and readers of CVIR, your dedication to the profession, and your loyalty both to the journal and to CIRSE. For all of this, we owe you our thanks and respect.

  7. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  8. [Regulating radiological protection and the role of health authorities].

    Science.gov (United States)

    Arias, César F

    2006-01-01

    This article summarizes the development of protection against ionizing radiation and explains current thinking in the field. It also looks at the decisive role that regulatory agencies for radiological protection must play and the important contributions that can be made by health authorities. The latter should take an active part in at least three aspects: the formal education of health personnel regarding radiological protection; the medical care of individuals who are accidentally overexposed, and the radiological protection of patients undergoing radiological procedures. To this end, health professionals must possess sufficient knowledge about radiological protection, promote the use of proper equipment, and apply the necessary quality assurance procedures. Through their effective intervention, national health authorities can greatly contribute to reducing unnecessary doses of radiation during medical procedures involving radiation sources and decrease the chances that radiological accidents will take place.

  9. Interventional radiology delivers high-value health care and is an Imaging 3.0 vanguard.

    Science.gov (United States)

    Charalel, Resmi A; McGinty, Geraldine; Brant-Zawadzki, Michael; Goodwin, Scott C; Khilnani, Neil M; Matsumoto, Alan H; Min, Robert J; Soares, Gregory M; Cook, Philip S

    2015-05-01

    Given the changing climate of health care and the imperative to add value, radiologists must join forces with the rest of medicine to deliver better patient care in a more cost-effective, evidence-based manner. For several decades, interventional radiology has added value to the health care system through innovation and the provision of alternative and effective minimally invasive treatments, which have decreased morbidity, mortality, and overall cost. The clinical practice of interventional radiology embodies many of the features of Imaging 3.0, the program recently launched by the ACR. We provide a review of some of the major contributions made by interventional radiology and offer general principles from that experience, which are applicable to all radiologists. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Patient radiation doses in the most common interventional cardiology procedures in croatia: First results

    International Nuclear Information System (INIS)

    Brnic, Z.; Krpan, T.; Faj, D.; Kubelka, D.; Ramac, J. P.; Posedel, D.; Steiner, R.; Vidjak, V.; Brnic, V.; Viskovic, K.; Baraban, V.

    2010-01-01

    Apart from its benefits, the interventional cardiology (IC) is known to generate high radiation doses to patients and medical staff involved. The European Union Medical Exposures Directive 97/43/EURATOM strongly recommend patient dosimetry in interventional radiology, including IC. IC patient radiation doses in four representative IC rooms in Croatia were investigated. Setting reference levels for these procedures have difficulties due to the large difference in procedure complexity. Nevertheless, it is important that some guideline values are available as a benchmark to guide the operators during these potentially high-dose procedures. Local and national diagnostic reference levels (DRLs) were proposed as a guidance. A total of 138 diagnostic (coronary angiography, CA) and 151 therapeutic (PTCA, stenting) procedures were included. Patient irradiation was measured in terms of kerma-area product (KAP), fluoroscopy time (FT) and number of cine-frames (F). KAP was recorded using calibrated KAP-meters. DRLs of KAP, FT and F were calculated as third quartile values rounded up to the integer. Skin doses were assessed on a selected sample of high skin dose procedures, using radiochromic films, and peak skin doses (PSD) were presented. A relative large range of doses in IC was detected. National DRLs were proposed as follows: 32 Gy cm 2 , 6.6 min and 610 frames for CA and 72 Gy cm 2 , 19 min and 1270 frames for PTCA. PSD 2 Gy in 8% of selected patients. Measuring the patient doses in radiological procedures is required by law, but rarely implemented in Croatia. The doses recorded in the study are acceptable when compared with the literature, but optimisation is possible. The preliminary DRL values proposed may be used as a guideline for local departments, and should be a basis for radiation reduction measures and quality assurance programmes in IC in Croatia. (authors)

  11. Patients exposure assessment for radiographic procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Stankovic, K.; Lazarevic, Dj.; Ciraj-Bjelac, O.)

    2007-01-01

    In this work the results of dose assessment for the most frequent radiographic procedures in diagnostic radiology are shown. Entrance surface doses were assessed for 7 radiographic procedures. Three hospitals, six x-ray units in total, were enrolled in investigation. Patient doses were estimated based on results of x-ray tube output measurements. Finally, doses were compared with Diagnostic reference level. Higher dose values were observed for chest examinations. In comparison with results from other countries, doses from this procedure in Serbia are significantly higher. Estimated doses for other procedures were well below Diagnostic reference levels [sr

  12. Interventional radiology (IVR). The history, status quo, and prospect

    International Nuclear Information System (INIS)

    Furui, Shigeru; Kohtake, Hiroshi

    2007-01-01

    Interventional radiology (IVR) is a clinical practice that therapy and/or biopsy are performed under guidance by images obtainable by the contrast angiography, ultrasonography, CT, MRI and so on. This paper describes its history, present status and future prospect. Actual operation procedure, recent trend and progress as well are explained in the order of arterial embolization, IVR in hepatic tumors, PTA (percutaneous transluminal angiography) and MS (metallic stent indwelling), MS applied to others than artery, S-G (stent-graft), IVR in portal hypertension, development of IVR devices in Japan, and radiation exposure and its protection in IVR. Many IVR devices have been developed in Japan for as long as these 30 years, a part of which is marketed. Skin exposure in patients is unavoidable in IVR with X-ray and thereby regulations by Food and Drug Administration (FDA) and International Commission of Radiological Protection (ICRP) are introduced for their benefit. Systems for dose estimation in patients and efforts to reduce the dose are mentioned to be important and radiologists themselves should make effort to decrease their own exposure in consideration of the dose limits defined in the law. Problems in Japan are expensiveness of IVR devices, and slow-paced approval of new devices by authority and by health insurance agent. The author recommends doctors to have expert radiologist's advice in IVR. (R.T.)

  13. Promoting interventional radiology in clinical practice of emergency medicine

    International Nuclear Information System (INIS)

    Zhou Bing; Yuan Jianhua

    2009-01-01

    Interventional radiology has lot of advantages in dealing with various emergencies. The technique is minimally-invasive, highly-effective and immediately-efficient, moreover, it integrates the diagnosis with the therapy perfectly. Besides, the interventional techniques applied in emergency medicine include not only the vascular interventions,such as embolization, embolectomy, etc, but also the nonvascular interventions, such as tracheal s tent implantation, percutaneous vertebroplasty and so forth. However, importance has not been attached to the clinical use of interventional therapy in emergency medicine so far. It is imperative for us to promote the acceptance of interventional therapy in emergency medicine as well as to popularize the technique in clinical practice. (authors)

  14. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  15. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States); Carelsen, Bart [Philips HealthCare, Clinical Science Interventional X-ray (Netherlands); Diehm, Nicolas [Kantonsspital Aarau, Clinical and Interventional Angiology (Switzerland); Benenati, James F.; Peña, Constantino S. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States)

    2015-10-15

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

  16. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    International Nuclear Information System (INIS)

    Baumann, Frederic; Katzen, Barry T.; Carelsen, Bart; Diehm, Nicolas; Benenati, James F.; Peña, Constantino S.

    2015-01-01

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter

  17. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for radiology...

  18. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  19. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites

    International Nuclear Information System (INIS)

    McNeil, S. M.; Lai, P.; Connolly, B. L.; Gordon, C. L.

    2013-01-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10-to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam. (authors)

  20. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites.

    Science.gov (United States)

    McNeil, Sarah M; Lai, Priscilla; Connolly, Bairbre L; Gordon, Christopher L

    2013-12-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10- to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam.

  1. The Provision of Interventional Radiology Services in Europe: CIRSE Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Tsetis, Dimitrios, E-mail: tsetis@med.uoc.gr [University of Crete, Interventional Radiology Unit, Department of Radiology, University Hospital Heraklion, Faculty of Medicine (Greece); Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk [John Radcliff Hospital, Radiology Department (United Kingdom); Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it [Sapienza – University of Rome, Interventional Radiology Unit, Department of Radiological Sciences (Italy); Roberston, Iain, E-mail: bsiriain@gmail.com [Gartnavel General Hospital, Interventional Radiology Unit (United Kingdom); Krokidis, Miltiadis, E-mail: mkrokidis@hotmail.com [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology (United Kingdom); Delden, Otto van, E-mail: o.m.vandelden@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands); Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de [University Hospital of Heidelberg, Department for Diagnostic and Interventional Radiology (Germany); Müller-Hülsbeck, Stefan, E-mail: muehue@diako.de [Ev.-Luth. Diakonissenanstalt zu Flensburg – Zentrum für Gesundheit und Diakonie, Diagnostische u. Interventionelle Radiologie/Neuroradiologie (Germany); Szerbo-Trojanowska, Malgorzata, E-mail: m.trojanowska@umlub.pl [Medical University of Lublin, Interventional Radiology (Poland); Lee, Michael, E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland); Morgan, Robert, E-mail: robert.morgan@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom); Brountzos, Elias, E-mail: ebrountz@med.uoa.gr [National and Kapodistrian University of Athens (Greece); Belli, Anna Maria, E-mail: Anna.belli@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom)

    2016-04-15

    Interventional Radiology (IR) is an essential part of modern medicine, delivering minimally invasive patient-focused care, which has been proven to be safe and effective in both elective and emergency settings. The aim of this document is to outline the core requirements and standards for the provision of Interventional Radiological services, including training, certification, manpower, and accreditation. The ultimate challenge will be the adoption of these recommendations by different countries and health economies around the world, in turn ensuring equal access to IR treatments for all patients, the appropriate distribution of resources for IR service provision as well as the continued development of safe and high-quality IR services in Europe and beyond.

  2. The Provision of Interventional Radiology Services in Europe: CIRSE Recommendations

    International Nuclear Information System (INIS)

    Tsetis, Dimitrios; Uberoi, Raman; Fanelli, Fabrizio; Roberston, Iain; Krokidis, Miltiadis; Delden, Otto van; Radeleff, Boris; Müller-Hülsbeck, Stefan; Szerbo-Trojanowska, Malgorzata; Lee, Michael; Morgan, Robert; Brountzos, Elias; Belli, Anna Maria

    2016-01-01

    Interventional Radiology (IR) is an essential part of modern medicine, delivering minimally invasive patient-focused care, which has been proven to be safe and effective in both elective and emergency settings. The aim of this document is to outline the core requirements and standards for the provision of Interventional Radiological services, including training, certification, manpower, and accreditation. The ultimate challenge will be the adoption of these recommendations by different countries and health economies around the world, in turn ensuring equal access to IR treatments for all patients, the appropriate distribution of resources for IR service provision as well as the continued development of safe and high-quality IR services in Europe and beyond.

  3. Implementation of procedures of radiological protection in the section of Radiology of the emergency Hospital of Porto Alegre-Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzini, F.; Rizzati, M.R. [Emergency Hospital of Porto Alegre, HPS (Brazil)

    1998-12-31

    The Emergency Hospital of Porto Alegre (HPS) is one of the main reference centers for the population in the attendance of medical emergencies/urgencies. The Section of Radiology, which informs the patients clinical conditions based on radiological images, is the most demanded section of the hospital (81.43 % of the medical cases request radiological exams) in the aid of the diagnosis, in which excels for the search of the quality in the health branch. In this work are presented the procedures to have been implemented about radiological protection according to effective norm, methods, ways and conditions to satisfy the radiation workers and the internal and external patients. (Author)

  4. Implementation of procedures of radiological protection in the section of Radiology of the emergency Hospital of Porto Alegre-Brazil

    International Nuclear Information System (INIS)

    Lorenzini, F.; Rizzati, M.R.

    1998-01-01

    The Emergency Hospital of Porto Alegre (HPS) is one of the main reference centers for the population in the attendance of medical emergencies/urgencies. The Section of Radiology, which informs the patients clinical conditions based on radiological images, is the most demanded section of the hospital (81.43 % of the medical cases request radiological exams) in the aid of the diagnosis, in which excels for the search of the quality in the health branch. In this work are presented the procedures to have been implemented about radiological protection according to effective norm, methods, ways and conditions to satisfy the radiation workers and the internal and external patients. (Author)

  5. Sedation and patient monitoring in vascular and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    McDermott, V G.M.; Chapman, M E; Gillespie, I [Royal Infirmary, Edinburgh (United Kingdom)

    1993-08-01

    A postal survey of British and Irish interventional radiologists was carried out in 1991 to assess current practice with respect to sedation and monitoring of patients during angiography and interventional procedures. The response rate was 65%, 49% of patients are fasted prior to angiography and 68% prior to interventional procedures. Radiologists participate in obtaining consent in 60% of cases. Patients are often (50%) sedated for angiography and usually (62-94% depending on the procedure) sedated for interventional procedures. Nurses are present for most procedures, but are given the task of monitoring the patient's vital signs in only 49% of cases. Anaesthetists are present for less than 10% of interventional procedures. The findings indicate a wide variation in practice and a need to standardize practice at a uniform high level. (author).

  6. Occupational exposure of diagnostic radiology staff in Israel during 1994-1996

    International Nuclear Information System (INIS)

    Biran, T.; Malchi, S.; Shamai, Y.

    1997-01-01

    Personnel who perform interventional radiological procedures which involve long fluoroscopy times and with a high workload, may receive radiation doses comparable to one of the dose limits suggested by the International Commission on Radiological protection. It is therefore important to monitor accurately the radiation dose to every staff member. who is involved in fluoroscopy procedures. (authors)

  7. Occurrence of undesirable tissue reaction in interventional vascular radiology; La radiologie interventionnelle et les risques associes: etude d'un cas clinique

    Energy Technology Data Exchange (ETDEWEB)

    Thouveny, Francine [Service de radiologie, Centre Hospitalier Universitaire d' Angers, 4, rue Larrey, 49933 Angers Cedex 9 (France)

    2011-07-15

    After lengthy technological development, the constantly evolving diagnostic and therapeutic interventional radiology procedures have become vital factors in patient care. X-rays remain the key tool for these techniques in a large number of cases, including certain complex vascular pathologies for which endovascular treatment is associated with prolonged irradiation. The risk they represent are however outweighed by the underlying therapeutic stakes and remains of secondary medical concern. In these difficult cases, which require maximum concentration on the intervention, the practitioner will need to be aided by tools that strictly limit and monitor the dose. The manufacturers and radiological physicists must be involved in configuring the facilities used and the health professionals in determining reference levels and professional recommendations that take account of the dose optimisation tools. (authors)

  8. Patient Safety in Interventional Radiology: A CIRSE IR Checklist

    NARCIS (Netherlands)

    Lee, M. J.; Fanelli, F.; Haage, P.; Hausegger, K.; van Lienden, K. P.

    2012-01-01

    Interventional radiology (IR) is an invasive speciality with the potential for complications as with other invasive specialities. The World Health Organization (WHO) produced a surgical safety checklist to decrease the morbidity and mortality associated with surgery. The Cardiovascular and

  9. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  10. Finger doses during interventional radiology: The value of flexible protective gloves

    International Nuclear Information System (INIS)

    Vehmas, T.

    1991-01-01

    Finger doses of radiologists and assistants during 19 interventional radiological procedures were measured with thermoluminescent dosimeters (TLDs), and two types of flexible protective gloves were compared with each other. There were considerable differences in doses between different sites of TLDs on fingers. The exact site of TLDs on hands/fingers should thus be reported in papers. Both gloves were also irradiated through an Alderson phantom and the attenuation values were measured. The gloves with slightly greater attenuation proved to be significantly less comfortable to use. Wearing flexible protective gloves did not lengthen screening times as compared to a previous study in the same department. Various aspects of using such gloves are discussed. The attenuation values of gloves reported by the manufacturers may not apply under all clinical circumstances. (orig.) [de

  11. A feasibility inquiry on the radiodermatitis secondary to an interventional radiology act

    International Nuclear Information System (INIS)

    Roudier, C.; Pirard, Ph.; Donadieu, J.

    2006-01-01

    The radiodermatitis is a burning of skin tissue and subcutaneous tissue in relation with ionizing radiation. In the medical practice, outside radiotherapy excluded of our study, it is observed only with acts of interventional radiology. The consequences of a radiodermatitis can be aesthetic, with appearance of a scar or a definitive alopecia, functional with loss of substance needing sometimes a remedial surgical act and finally oncologic with a risk of localised skin cancer. A radiodermatitis can appear with a radiation dose of 2 grays and its intensity worsens with the dose. Since the late 1970's about 200 cases of radiodermatitis have been reported. the most of cases have been reported between 1993 and 2000 and less than ten cases have been reported since 2000, suggesting a possible reduction of incidence explainable by a concomitant improvement of technological quality of the equipment. In order to confirm this eventual trend az feasibility study has been organised and is reported in this article. Given the results, this complication is still existing. In spite of the small number of observed cases, it is to notice that every procedures of interventional radiology are concerned. The preliminary character of this study encourages the institute of Health surveillance to work on the elaboration of a program of radiodermatitis surveillance. It could be associated to actions of improvement of the prevention and follow-up of patients, of feedback, and making easy an optimization of the practices. (N.C.)

  12. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  13. Cost analysis in interventional radiology-A tool to optimize management costs

    International Nuclear Information System (INIS)

    Clevert, D.-A.; Stickel, M.; Jung, E.M.; Reiser, M.; Rupp, N.

    2007-01-01

    Objective: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. Materials and methods: All products used in Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. Results: Total annual material turnover was 353,000 Euro . The value of all A-products determined by the inventory was 260,000 Euro . Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year Euro . The resulting total saving was 17,200 Euro . Improved stores management added another 37,500 Euro. The total cost cut of 52,000 Euro is equivalent to 14.7% of annual expenses. Conclusion: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients

  14. The role of morbidity and mortality meetings in interventional radiology

    International Nuclear Information System (INIS)

    Mok, Philip S.; Tan, Eva Y.; Baerlocher, Mark O.; Athreya, Sriharsha

    2012-01-01

    Purpose: To understand the current practice of interventional radiology (IR) morbidity and mortality (M and M) meetings among interventional radiologists in Europe, and to develop a set of results-based recommendations to increase the prevalence of IR M and M meetings. Materials and methods: Online electronic surveys were sent to members of the Cardiovascular and Interventional Radiology Society of Europe (CIRSE). Each survey consisted of 18 questions pertaining to IR M and M meetings. Results: A total of 150 CIRSE members responded to the survey. Approximately 47% of respondents held IR M and M meetings in their departments. Among those who held IR M and M meetings, 42% held them monthly and 68% rated the quality of the meetings as good or excellent. Of those who did not have M and M meetings, 94% were interested in incorporating M and M meetings into their future practice. The most common reasons for not holding IR M and M meetings were lack of time (68%) and small IR practice groups (43%). A total of 85% were interested in learning more about IR M and M meetings. The preferred method of education about M and M meetings included annual radiology meetings (44%), peer-reviewed articles in radiology journals (31%), websites (26%), and newsletters (15%). Conclusions: The data demonstrate that although current practice of M and M meetings in European IR departments is limited, the majority of respondents believe that M and M meetings are beneficial to their practice. There is a need for guidelines or standards of practice to incorporate such meetings in IR departments to prevent medical errors, which may ultimately lead to enhanced patient safety and outcomes.

  15. Opportunity of interventional radiology: advantages and application of interventional technique in biological target therapy

    International Nuclear Information System (INIS)

    Teng Gaojun; Lu Qin

    2007-01-01

    Interventional techniques not only provide opportunity of treatment for many diseases, but also alter the traditional therapeutic pattern. With the new century of wide application of biological therapies, interventional technique also shows extensive roles. The current biological therapy, including gene therapy, cell transplantation therapy, immunobiologic molecule therapy containing cell factors, tumor antibody or vaccine, recombined proteins, radioactive-particles and targeting materials therapy, can be locally administrated by interventional techniques. The combination of targeting biological therapies and high-targeted interventional technique holds advantages of minimal invasion, accurate delivery, vigorous local effect, and less systemic adverse reactions. Authors believe that the biological therapy may arise a great opportunity for interventional radiology, therefore interventional colleagues should grasp firmly and promptly for the development and extension in this field. (authors)

  16. Modern radiology in oncology and waiting lists for procedures: Breast cancer screening in Slovenia

    Directory of Open Access Journals (Sweden)

    Maksimiljan Kadivec

    2007-12-01

    Full Text Available Background: Good and modern radiology equipment is needed for successful treatment of the oncologic patients. New Department of Radiology of the Institute of Oncology Ljubljana is entirely digital and can compete with the similar radiologic departments all over the world. It si possible to perform all the new modern procedures that the oncologic patients need. Important diagnostic modality is PET CT that fulfill the selection of the diagnostic procedures for cancer patients. The problem of Slovenian radiology is lack of the radiologists. This problem could be solved with telemedicine and properly awarded work that was performed. Waiting lists for procedures like CT, MR, US are short for oncologic patients in comparison with the other radiologic units in Slovenia.Conclusions: At the beginning of the year 2008 we will start the Breast Cancer Screening Program in Slovenia. It is organized by Institute of Oncology Ljubljana (DORA program. Breast cancer screening program will be centralized, in accordance with of the European guidelines for quality assurance in breast cancer screening and diagnosis 2006 (fourth edition and supervision of reference breast screening center. The main goal of the breast cancer screening program in Slovenia is reduction of the breast cancer death for 25 % or more.

  17. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2011-03-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  18. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2012-02-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  19. Development of a real-time extremity dose monitor for personnel in interventional radiology

    International Nuclear Information System (INIS)

    Ban, Nobuhiko; Kusama, Tomoko; Adachi, Akiko

    2000-01-01

    Protection of personnel in interventional radiology is one of the most important issues of radiological protection in medicine. Fluoroscopically guided interventional procedures require the operation near X-ray beam, which brings a considerable hand exposure to the operators. For the purpose of effectual control of their extremity doses, we have developed a real-time extremity dose monitor which is worn on a strap around the wrist. The monitor consists of a silicon semiconductor detector, thin lithium battery and a waterproof frame with a four-digit LED display. Experiment was carried out to examine a response of the monitor to diagnostic X-rays. A practical test was also performed to evaluate usability in the actual interventional procedures. In the experiment, the extremity dose monitor was placed on an arm phantom and exposed to diagnostic X-rays. Readings of the monitor were compared to those of Capintec PS-033 shallow chamber. The monitor was highly sensitive to diagnostic X-rays. It showed a linear response down to doses of a few tens of microsieverts. For high dose-rate exposure, however, a slight decrease in the response was observed, about 10% of counting loss for 80 kV, 40 mA X-ray at one meter from the focus. With regard to energy dependence, variation was within 20% for 60 to 100 kV X-rays. The monitor showed a good angular response in general, except lateral geometry facing the far side from a detector center. In the practical test, hand exposures of medical staff were measured with the extremity dose monitor. They were also asked to fill in a questionnaire regarding size and weight of the monitor, clarity of the display and usefulness. The subjects consisted of physicians, technicians and nurses who engaged in angiography, PTCD, CT-biopsy, barium enema and so on. The readings of the monitor were less than 1 mSv in most cases while 93 mSv was recorded in an extreme case due to direct-beam exposure. In some cases, TLD rings were used together with the

  20. Development of a real-time extremity dose monitor for personnel in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Nobuhiko; Kusama, Tomoko [Oita University of Nursing and Health Sciences, Oita (Japan); Adachi, Akiko [Oita Medical University, Oita (JP)] [and others

    2000-05-01

    Protection of personnel in interventional radiology is one of the most important issues of radiological protection in medicine. Fluoroscopically guided interventional procedures require the operation near X-ray beam, which brings a considerable hand exposure to the operators. For the purpose of effectual control of their extremity doses, we have developed a real-time extremity dose monitor which is worn on a strap around the wrist. The monitor consists of a silicon semiconductor detector, thin lithium battery and a waterproof frame with a four-digit LED display. Experiment was carried out to examine a response of the monitor to diagnostic X-rays. A practical test was also performed to evaluate usability in the actual interventional procedures. In the experiment, the extremity dose monitor was placed on an arm phantom and exposed to diagnostic X-rays. Readings of the monitor were compared to those of Capintec PS-033 shallow chamber. The monitor was highly sensitive to diagnostic X-rays. It showed a linear response down to doses of a few tens of microsieverts. For high dose-rate exposure, however, a slight decrease in the response was observed, about 10% of counting loss for 80 kV, 40 mA X-ray at one meter from the focus. With regard to energy dependence, variation was within 20% for 60 to 100 kV X-rays. The monitor showed a good angular response in general, except lateral geometry facing the far side from a detector center. In the practical test, hand exposures of medical staff were measured with the extremity dose monitor. They were also asked to fill in a questionnaire regarding size and weight of the monitor, clarity of the display and usefulness. The subjects consisted of physicians, technicians and nurses who engaged in angiography, PTCD, CT-biopsy, barium enema and so on. The readings of the monitor were less than 1 mSv in most cases while 93 mSv was recorded in an extreme case due to direct-beam exposure. In some cases, TLD rings were used together with the

  1. Occupational radiation exposure of the personnel due to interventional radiology

    International Nuclear Information System (INIS)

    Wucherer, M.; Schmidt, T.; Loose, R.

    2000-01-01

    Applications of interventional radiology continue to be on an upward trend, some countries reporting a 100% increase within 2-4 years, so that the resulting radiation exposure of both patients and personnel is an issue of increasing importance. Whereas those applications in general are of advantage for the patients, they mean just a further health hazard for the medical personnel. It is therefore necessary to exploit all available means to reduce the occupational doses. Modern interventional radiology systems offer a range of measures for this purpose, as e.g. last-image-hold, or pulsed modes. Special attention has to be given to the exposure of hand and head. Particularly the hand is closest to the useful beam, and it should be a mandatory requirement to wear film rings. (orig./CB) [de

  2. Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures

    International Nuclear Information System (INIS)

    Osei, Ernest K; Barnett, Rob

    2009-01-01

    Diagnostic radiological imaging such as conventional radiography, fluoroscopy and computed tomography (CT) examinations will continue to provide tremendous benefits in modern healthcare. The benefit derived by the patient should far outweigh the risk associated with a properly conducted imaging examination. Nonetheless, it is very important to be able to quantify the risk associated with any radiological examination of patients, and effective dose has been considered a useful indicator of patient exposure. Quantification of the risks associated with radiological imaging is very important as such information will be helpful to physicians and their patients for comparing risks from various imaging examinations and for making informed decisions whenever there is a need for any radiological imaging. The determination of equivalent and effective doses in diagnostic radiology is of interest as a basis for estimates of risk from medical exposures. In this paper we describe a simple computer program OrgDose, which calculates the doses to 27 organs in the body and then calculates the organ equivalent and effective doses and the risk from various procedures in the radiology department including conventional radiography, fluoroscopy and computed tomography examinations. The program will be a useful tool for the medical and paramedical personnel who are involved with assessing organ and effective doses and risks from diagnostic radiology procedures.

  3. Active electronic personal dosemeter in interventional radiology

    International Nuclear Information System (INIS)

    Prlic, I.; Suric Mihic, M.; Vucic, Z.

    2008-01-01

    A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that is, above the protective apron, continuously measured and recorded the received doses and, as a novelty, dose rates as a function of time, thus yielding a unique record of occupational doses and dose rates pattern at the working place. This paper presents and discusses one typical daily pattern in which seven percutaneous interventions were performed. (authors)

  4. Complex intravenous anesthesia in interventional procedures

    International Nuclear Information System (INIS)

    Xie Zonggui; Hu Yuanming; Huang Yunlong; You Yong; Wu Juan; Huang Zengping; Li Jian

    2006-01-01

    Objective: To evaluate the value and safety of Diprivan and Fentany intravenous administration of analgesia in interventional procedures. Methods: Diprivan with Fentany intravenous administration for analgesia was used in eighty interventional procedures of sixty-five patients, without tracheal tube insertion. Vital signs including HR, BP, arterial oxygen saturation (SpO 2 ) and patients' reaction to operating were recorded. Results: Intravenous anesthesia was cared out successfully in eighty interventional procedures, with patients under sleeping condition during the operation, together with no pain and no agony memory of the procedure. The amount of Diprivan was 500±100 mg and Fentany was 0.2±0.025 mg. Mean arterial pressure and SpO 2 were 11.4±2.2 kPa, 10.6±2.1 kPa and 98±1.0, 96±1.5 respectively before and after ten minutes of the operation, with no significant difference. Conclusions: Diprivan with Fentany intravenous administration for interventional procedure analgesia possess good safety, painless and no agony memory of the procedure; therefor ought to be recommended. (authors)

  5. Global view on the radiological protection of patients: PAHO position paper

    International Nuclear Information System (INIS)

    Borras, C.

    2001-01-01

    The Pan American Health Organization/World Health Organization (PAHO/WHO), founded in 1902, initiated a radiological health programme in the 1950s. Within this programme, there are currently three lines of work: (a) radiology services; (b) radiation safety; and (c) radiological emergencies. Radiology services deals with health services for diagnostic and interventional imaging, and for radiation therapy. Radiation safety studies the three types of exposures to both ionizing and non-ionizing radiation: occupational; medical; and public. Radiological emergencies involve radioactive waste management programmes and emergency plans. The radiological protection of patients is addressed in each of these areas: (a) when analysing the infrastructure of radiology services; and (b) when determining medical exposures; and (c) when investigating overexposures in interventional or therapeutic procedures or under-doses in radiation therapy. (author)

  6. Optimisation of patient and staff exposure in interventional cardiology

    International Nuclear Information System (INIS)

    Padovani, R.; Malisan, M.R.; Bernardi, G.; Vano, E.; Neofotistou, V.

    2001-01-01

    The Council Directive of the European Community 97/43/Euratom (MED) deals with the health protection of individuals against dangers of ionising radiation in relation to medical exposure, and also focuses attention on some special practices (Art. 9), including interventional radiology, a technique involving high doses to the patient. The paper presents the European approach to optimisation of exposure in interventional cardiology. The DIMOND research consortium (DIMOND: Digital Imaging: Measures for Optimising Radiological Information Content and Dose) is working to develop quality criteria for cineangiographic images, to develop procedures for the classification of complexity of therapeutic and diagnostic procedures and to derive reference levels, related also to procedure complexity. DIMOND project also includes aspects of equipment characteristics and performance and content of training in radiation protection of personnel working in interventional radiology field. (author)

  7. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology

    International Nuclear Information System (INIS)

    Mori, Hiroshige

    2015-01-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses’ annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units’ pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses. (practical matter)

  8. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    Science.gov (United States)

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  9. Applying 'Evidence-Based Medicine' Theory to Interventional Radiology.Part 2: A Spreadsheet for Swift Assessment of Procedural Benefit and Harm

    International Nuclear Information System (INIS)

    MacEneaney, Peter M.; Malone, Dermot E.

    2000-01-01

    AIM: To design a spreadsheet program to analyse interventional radiology (IR) data rapidly produced in local research or reported in the literature using 'evidence-based medicine' (EBM) parameters of treatment benefit and harm. MATERIALS AND METHODS: Microsoft Excel TM was used. The spreadsheet consists of three worksheets. The first shows the 'Levels of Evidence and Grades of Recommendations' that can be assigned to therapeutic studies as defined by the Oxford Centre for EBM. The second and third worksheets facilitate the EBM assessment of therapeutic benefit and harm. Validity criteria are described. These include the assessment of the adequacy of sample size in the detection of possible procedural complications. A contingency (2 x 2) table for raw data on comparative outcomes in treated patients and controls has been incorporated. Formulae for EBM calculations are related to these numerators and denominators in the spreadsheet. The parameters calculated are benefit -- relative risk reduction, absolute risk reduction, number needed to treat (NNT). Harm -- relative risk, relative odds, number needed to harm (NNH). Ninety-five per cent confidence intervals are calculated for all these indices. The results change automatically when the data in the therapeutic outcome cells are changed. A final section allows the user to correct the NNT or NNH in their application to individual patients. RESULTS: This spreadsheet can be used on desktop and palmtop computers. The MS Excel TM version can be downloaded via the Internet from the URL ftp://radiography.com/pub/TxHarm00.xls. CONCLUSION: A spreadsheet is useful for the rapid analysis of the clinical benefit and harm from IR procedures. MacEneaney, P.M. and Malone, D.E

  10. Surgical and interventional radiological management of adult epistaxis: systematic review.

    Science.gov (United States)

    Swords, C; Patel, A; Smith, M E; Williams, R J; Kuhn, I; Hopkins, C

    2017-12-01

    There is variation regarding the use of surgery and interventional radiological techniques in the management of epistaxis. This review evaluates the effectiveness of surgical artery ligation compared to direct treatments (nasal packing, cautery), and that of embolisation compared to direct treatments and surgery. A systematic review of the literature was performed using a standardised published methodology and custom database search strategy. Thirty-seven studies were identified relating to surgery, and 34 articles relating to interventional radiology. For patients with refractory epistaxis, endoscopic sphenopalatine artery ligation had the most favourable adverse effect profile and success rate compared to other forms of surgical artery ligation. Endoscopic sphenopalatine artery ligation and embolisation had similar success rates (73-100 per cent and 75-92 per cent, respectively), although embolisation was associated with more serious adverse effects (risk of stroke, 1.1-1.5 per cent). No articles directly compared the two techniques. Trials comparing endoscopic sphenopalatine artery ligation to embolisation are required to better evaluate the clinical and economic effects of intervention in epistaxis.

  11. Control development of radiation protection and safety on personnel eye lens of interventional radiology

    International Nuclear Information System (INIS)

    Titik Kartika; Ishak

    2013-01-01

    The review on radiation protection and safety to the lens of personnel especially in interventional radiology activities has been carried out. The use of radiation in interventional radiology installations provide significant exposure to the lens of the eye, especially personnel. The results of the latest various surveys and researches on the effects of low dose radiation to the eye lens indicates that the eye lens dose threshold is less than the preconceived values. Based on these facts, recently, ICRP and IAEA provides recommendations regarding the reduction of the value of the eye lens dose limit for personnel. BAPETEN have adopted the value of the eye lens dose limit in the development of new regulations on radiation protection and safety. However, the application of this provision has various challenges that BAPETEN provide 3 (three) years transitional period. These challenges include the problem of monitoring the eye lens dose, the eye lens protective equipment which is not adequate, the lack of understanding of personnel related to the risk of low radiation to the eye lens, as well as the proper procedures to mitigate those risks. BAPETEN as a regulatory agency is expected to provide solutions to the problems faced by the stake holders. Therefore, to answer the challenge, it is necessary to develop better monitoring of radiation protection and safety. (author)

  12. Comparison of fluoroscopy-guided pull-type percutaneous radiological gastrostomy (pull-type-PRG) with conventional percutaneous radiological gastrostomy (push-type-PRG): clinical results in 253 patients

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang; Schneider, J.; Dueber, C.; Pitton, M.B. [University Medical Center of the Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany)

    2011-11-15

    To analyze the clinical results and complications of fluoroscopy guided internal-external pull-type percutaneous radiological gastrostomy (pull-type-PRG) and conventional external-internal percutaneous radiological gastrostomy (push-type-PRG). A total of 253 patients underwent radiological gastrostomy between January 2002 and January 2010. Data were collected retrospectively from radiology reports, Chart review of clinical notes, procedure reports, discharge summaries and subsequent hospital visits. Statistical analysis was performed to compare the two methods for gastrostomy with respect to peri-interventional aspects and clinical results. 128 patients received the Pull-type-PRG whereas the other 125 patients were served with the Push-type-PRG. Indications for gastrostomy were similar in these two groups. The most frequent indications for the both methods were stenotic oesophageal tumors or head/neck tumors (54.7% in pull-type-PRG, 68% in push-type-PRG). Gastrostomy procedures were successful in 98.3% in pull-type-PRG compared to 92% in push-type-PRG. There was no procedure-related mortality. Compared to Push-type-PRG, the peri-interventional complication rate was significantly reduced in pull-type-PRG (14.8% versus 34.4%, P = 0.002). Compared to the external-internal push-type-PRG, the internal-external Pull-type-PRG showed a high primary success rate and a decreased incidence of peri-interventional complications. (orig.)

  13. Comparison of fluoroscopy-guided pull-type percutaneous radiological gastrostomy (pull-type-PRG) with conventional percutaneous radiological gastrostomy (push-type-PRG): clinical results in 253 patients

    International Nuclear Information System (INIS)

    Yang, Yang; Schneider, J.; Dueber, C.; Pitton, M.B.

    2011-01-01

    To analyze the clinical results and complications of fluoroscopy guided internal-external pull-type percutaneous radiological gastrostomy (pull-type-PRG) and conventional external-internal percutaneous radiological gastrostomy (push-type-PRG). A total of 253 patients underwent radiological gastrostomy between January 2002 and January 2010. Data were collected retrospectively from radiology reports, Chart review of clinical notes, procedure reports, discharge summaries and subsequent hospital visits. Statistical analysis was performed to compare the two methods for gastrostomy with respect to peri-interventional aspects and clinical results. 128 patients received the Pull-type-PRG whereas the other 125 patients were served with the Push-type-PRG. Indications for gastrostomy were similar in these two groups. The most frequent indications for the both methods were stenotic oesophageal tumors or head/neck tumors (54.7% in pull-type-PRG, 68% in push-type-PRG). Gastrostomy procedures were successful in 98.3% in pull-type-PRG compared to 92% in push-type-PRG. There was no procedure-related mortality. Compared to Push-type-PRG, the peri-interventional complication rate was significantly reduced in pull-type-PRG (14.8% versus 34.4%, P = 0.002). Compared to the external-internal push-type-PRG, the internal-external Pull-type-PRG showed a high primary success rate and a decreased incidence of peri-interventional complications. (orig.)

  14. Radiological protection in the interventional techniques: experience in the Pain Clinic of the CIMEQ; Proteccion radiologica en las tecnicas intervencionistas: experiencia en la Clinica del Dolor del CIMEQ

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, M. C.; Benitez N, P. P.; Gonzalez G, Y. [Centro de Investigaciones Medico Quirurgicas, Av. 216 Esq. 11B, Playa Siboney, 6096 La Habana (Cuba); Martinez G, A.; Gonzalez R, N. [Centro de Proteccion e Higiene de las Radiaciones, Carretera de la Cantera, Victoria II, Km. 21.5 Guanabacoa, La Habana (Cuba); Sanchez Z, L. R., E-mail: mayka@infomed.sld.cu [Hospital C. Q. Hermanos Ameijeiras, San Lazaro 701, Centro Habana, La Habana (Cuba)

    2014-08-15

    The Pain Clinic of the CIMEQ offers treatment to patients with different pathologies, using interventional techniques as the radiology like visual guide to reach the target structure and to apply the election technique. The personnel that carry out these procedures are inserted in the program of radiological surveillance of the institution, reason for which a radiological event could be detected where the main physician responsible of the service was implied. In this work the results of an investigation are presented realized with the objective of to know the causes of the event and to determine the necessary measures to avoid that this repeats again. The investigation was oriented to three fundamental aspects: medical exam of the affected worker; evaluation of the operational procedures from the radiological protection view point; and dosimetric measurements simulating the real conditions of work for which were used ionization chamber, radiometer and PMMA mannequin. As a result of the medical exam was detected that the main physician of the service did not use during the execution of all the procedures the extremities dosimetry and that he presented a radio induced erythema in the right hand, reason for which he was separated of the activity with ionizing radiations, until the conclusion of the investigation. With relationship to the evaluation of the operational procedures from the radiological protection view point, was verified that the medical physician not carried out any collimation of the beam and he was located in the positions where the dose rate reached the maximum values, frequently introducing the hands in the direct beam; that which implied an overexposure of the superior extremities and a not optimized exposure for whole body. This result was proven with the realized experimental measurements, which gave dose estimated values in extremities of the order of the deterministic effects. The investigation facilitated to introduce modifications in the

  15. Patients and personnel radiation protection in interventional radiology and in surgery

    International Nuclear Information System (INIS)

    Menechal, P.; Valero, M.; Godet, J.L.

    2009-01-01

    The development of the interventional radiology and acts realised under radiological guiding is a real benefit for patients. The doses delivered can however, generate important detriments (determinist effects). the patients and the personnel are exposed to important doses, heterogeneous and very different doses according the operator, the patient morphology and the treated pathology. This theme is considered by the the nuclear safety Authority as a priority in the medical medium. (N.C.)

  16. Interventional radiology techniques for the diagnosis of lymphoma or leukemia

    International Nuclear Information System (INIS)

    Garrett, Kevin M.; Hoffer, Fredric A.; Behm, Frederick G.; Gow, Kenneth W.; Hudson, Melissa M.; Sandlund, John T.

    2002-01-01

    Heading AbstractBackground. Fluid aspiration, percutaneous biopsy, and catheter drainage are standard minimally invasive methods of diagnosing lymphoma or leukemia in adults.Objective. To determine the effectiveness of interventional radiologic techniques in diagnosing specific hematologic malignancies in children.Methods. During a 4-year period, 22 patients (16 male, 6 female; median age, 13 years) underwent 25 percutaneous biopsies, 6 fluid aspirations, 3 catheter drainages, and 1 needle localization for diagnosing suspected hematologic malignancy.Results. For Hodgkin's disease, the procedures yielded 6 true-positive (TP) results, 2 true-negative (TN) results, and 2 false-negative (FN) results; for non-Hodgkin lymphoma (NHL), 14 TP results, 1 TN result, and 3 FN results; and for leukemia, 4 TP results and 3 FN results. Percutaneous biopsies yielded 16 TP results, 3 TN results, and 6 FN results. Aspirations and drainages yielded 8 TP results and 1 FN result. The one needle localization yielded a FN result. Overall sensitivity was 75%±7.3%; specificity, 100%; and accuracy, 77%±7.1%.Conclusion. Percutaneous biopsy of lymphoma is usually diagnostic. Drainage or aspiration of a fluid collection associated with NHL or leukemia is often diagnostic and is less invasive than biopsy. These procedures are minimally invasive and effective for diagnosing pediatric hematologic malignancies. (orig.)

  17. Merrill's Atlas of radiographic positions and radiologic procedures. Volumes 1-3. Sixth edition

    International Nuclear Information System (INIS)

    Ballinger, P.W.

    1985-01-01

    Merrill's Atlas describes and explains the routine and specialized radiologic procedures for all body systems. This edition thoroughly reorganized, updated and expanded. Volumes one and two describe all routine and flouroscopic procedures; and volume three describes more specialized areas in the profession

  18. Pilot study of the dose in crystalline lens in the interventional radiology practice; Estudio piloto de la dosis en cristalino en la practica de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Castro, A.; Martinez, A.; Fernandez, A.; Molina, D. [Centro de Proteccion e Higiene de las Radiaciones, Carretera de la Cantera, Victoria II, Km. 21.5 Guanabacoa, La Habana (Cuba); Sanchez, L.; Diaz, A., E-mail: ailza@cphr.edu.cu [Hospital Clinico Quirurgico Hermanos Ameijeiras, San Lazaro 701, Centro Habana, La Habana (Cuba)

    2014-08-15

    The interventional radiology involves considerable exposure levels for the occupationally exposed personnel (OEP). The doses can encompass a wide range of values in dependence of the function that develops the personnel and the complexity of each procedure. In organs like the crystalline lens and skin values can be reached that imply the appearance of deterministic effects if is not fulfilled the appropriate measures of radiological protection. This has been demonstrated through multiple studies, among those that the retrospective study of damages in the crystalline lens and dose has been one of those most commented, known as RELID. The objective of that study was to examine the opacity prevalence in the crystalline lens in workers linked to the interventional cardiology and to correlate it with the occupational exposition. The obtained results contributed to that the ICRP recommend a new limit value of equivalent dose for crystalline lens of 20 mSv in one year. With the objective of analyzing the operational implications, in the radiological surveillance programs that they could originate with the new recommendations was developed a pilot study to evaluate the dose in crystalline lens in the OEP linked to the interventional radiology in a Cuban hospital. For this, an anthropomorphic mannequin RANDO-ALDERSON was used on which thermoluminescent dosimeters were placed below and above of the leaded apron and in different positions at level of the crystalline lens: above, below and to the sides of the leaded lenses that the personnel uses routinely. The mannequin was located on the same positions that occupy the main specialist that execute the procedure, as well as of the nurse to assist him. The measurements were made simulating the more representative procedures about complexity, duration time and exposure rate. The used dosimeters were RADOS model for whole body composed of two thermoluminescent detectors Gr-200 (LiF: Mg, Cu, P) to evaluate personal equivalent dose

  19. Interventional radiology emergency service provision for a large UK urban population: Initial 3.5 years of experience

    International Nuclear Information System (INIS)

    Christie, A.; Robertson, I.; Moss, J.

    2013-01-01

    Aim: To review the activity and impact of an out-of-hours (OOH) interventional radiology service introduced in Glasgow in 2007. Material and methods: A retrospective review of the first 42 months formal OOH activity across 11 hospital sites covering a population of 1.2 million was undertaken. The 30 day mortality and cause of death was logged for each procedural subtype [nephrostomy, biliary and abscess drainage, enteric stenting, transjugular intrahepatic porto-systemic shunt (TIPS), thoracic endovascular aortic aneurysm repair (TEVAR), endovascular, and embolization]. Results: From October 2007 to March 2011, 502 cases were identified. The mean number of procedures performed per month was 12 (range 5–21). This represents an event rate of 12/100,000 population/year. A minority (11%) of cases were undertaken after midnight. The activity levels were stable over the 42 month study period. The most frequent procedures were percutaneous nephrostomy (32%) and embolization for haemorrhage (30%). Thirty-day mortality was 17% for the entire group but varied from 53% (biliary intervention) to 0% (TEVAR). There was no death following embolization for obstetric haemorrhage. Approximately half of the deaths were due to a failure of the procedure to control the underlying clinical problem. Conclusion: The demand for OOH services is important but not unduly onerous. There is no evidence of expansion of demand after launching such a service. Mortality rates probably reflect the underlying clinical status of this emergency patient group. Certain procedures carry a high mortality rate, raising issues of clinical judgement, appropriateness of intervention, and/or timing

  20. Estimate of dose in interventional radiology: a study of cases

    International Nuclear Information System (INIS)

    Pinto, N.; Braz, D.; Lopes, R.; Vallim, M.; Padilha, L.; Azevedo, F.; Barroso, R.

    2006-01-01

    Values of absorbed dose taken by patients and professionals involved in interventional radiology can be significant mainly for the reason of these proceedings taking long time of fluoroscopy There are many methods to estimate and reduce doses of radiation in the interventional radiology, particularly because the fluoroscopy is responsible for the high dose contribution in the patient and in the professional. The aim of this work is the thermoluminescent dosimetry to estimate the dose values of the extremities of the professionals involved in the interventional radiology and the product dose-area was investigated using a Diamentor. This evaluation is particularly useful for proceedings that interest multiple parts of the organism. In this study were used thermoluminescent dosimeters (LiF:Mg, Ti - Harshaw) to estimate the dose values of the extremities of the professionals and to calibrate them. They were irradiated with X rays at 50 mGy, in Kerma in air and read in the reader Harshaw-5500. The product dose-area (D.A.P.) were obtained through the Diamentor (M2-P.T.W.) calibrated in Cgy.cm 2 fixed in the exit of the X-rays tube. The patients of these study were divided in three groups: individuals submitted to proceedings of embolization, individuals submitted to cerebral and renal arteriography and individuals submitted to proceedings of Transjungular Inthahepatic Porta Systemic Stent Shunt (TIPS). The texts were always carried out by the same group: radiologist doctor), an auxiliary doctor and a nursing auxiliary. The section of interventional radiology has an Angiostar Plus Siemens equipment type arc C, in which there is trifocal Megalix X-ray tube and a intensifier of image from Sirecon 40-4 HDR/33 HDR. In this work the dose estimated values were 137.25 mSv/year for the doctors, 40.27 mSv/year for the nursing and 51.95 mSv/year for the auxiliary doctor and they are below the rule, but in this study it was not taken in consideration the emergency texts as they were

  1. The interventional radiology business plan.

    Science.gov (United States)

    Beheshti, Michael V; Meek, Mary E; Kaufman, John A

    2012-09-01

    Strategic planning and business planning are processes commonly employed by organizations that exist in competitive environments. Although it is difficult to prove a causal relationship between formal strategic/business planning and positive organizational performance, there is broad agreement that formal strategic and business plans are components of successful organizations. The various elements of strategic plans and business plans are not common in the vernacular of practicing physicians. As health care becomes more competitive, familiarity with these tools may grow in importance. Herein we provide an overview of formal strategic and business planning, and offer a roadmap for an interventional radiology-specific plan that may be useful for organizations confronting competitive and financial threats. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  2. Radiologic protection in pediatric radiology: ICRP recommendations

    International Nuclear Information System (INIS)

    Sanchez, Ramon; Khong, Pek-Lan; Ringertz, Hans

    2013-01-01

    ICRP has provided an updated overview of radiation protection principles in pediatric radiology. The authors recommend that staff, radiologists, medical physicists and vendors involved in pediatric radiology read this document. For conventional radiography, the report gives advice on patient positioning, immobilization, shielding and appropriate exposure conditions. It describes extensively the use of pulsed fluoroscopy, the importance of limiting fluoroscopy time, and how shielding and geometry must be used to avoid unnecessary radiation to the patient and operator. Furthermore, the use of fluoroscopy in interventional procedures with emphasis on dose reduction to patients and staff is discussed in light of the increasing frequency, complexity and length ofthe procedures. CT is the main reason that medical imaging in several developed countries is the highest annual per capita effective radiation dose from man-made sources. The ICRP report gives extensive descriptions of how CT protocols can be optimized to minimize radiation exposure in pediatric patients. The importance of balancing image quality with acceptable noise in pediatric imaging and the controversies regarding the use of protective shielding in CT are also discussed.

  3. Occupational hand doses in interventional radiology

    International Nuclear Information System (INIS)

    Spasic Jokic, V.; Djurovic, B.; Lukac, S.

    2001-01-01

    In this paper we present the case of a radiologist performing interventional procedures. The radiologist works for number of interventional procedures, but we reported only percutaneous nephrostomy and percutaneous biliary drainage which represent about 30% of his occupational exposure. The radiologist is occupationally exposed for eighteen years and from 1995 has radiation injuries. From 1999, art. hypertension, cataract complicata incip.ou., onychodystrophia and hyperceratosis mani bill. The most important are hands skin injuries. In ordinary dosimetric control low doses less than 10 mGy per year were recorded, so personal dosimetry results and biological results are not in accordance. For that reason we performed additional measurements during many procedures and in this paper we present results for two chosen procedures. Radiation exposure of the radiologist's hands during 200 percutaneous nephrostomy and 63 percutaneous biliary drainage per year are reported. Exposures were measured with thermoluminescent dosemeters (TLD) type CaF 2 :Mn. Hand doses of equivalent of 221 μSv in average per drainage and 31 μSv in average per nephrostomy were recorded. (author)

  4. British Society of Interventional Radiology: Biliary Drainage and Stenting Registry (BDSR)

    International Nuclear Information System (INIS)

    Uberoi, R.; Das, N.; Moss, J.; Robertson, I.

    2012-01-01

    Objectives: This study was designed to audit current practice in percutaneous biliary drainage and stenting in the United Kingdom. Methods: In 2006, the British Society of Interventional Radiology set up the first web-based Biliary Drainage and Stenting Registry (BDSR). This consisted of a series of tick sheets, which were completed online. Data collection included technical and clinical success of the procedures and outcomes at discharge with a separate form for any follow-up visits. Two months before data analysis, all contributors were asked via email to complete any outstanding data. This paper reports on data collected between November 1, 2006 and August 18, 2009. Results: A total of 833 procedures were recorded and were entered by 62 operators from 44 institutions within the United Kingdom. There were 455 men and 378 women with a median age of 69 (range 20–101) years.The majority of procedures were performed by a consultant. Successful drainage of the biliary tree was achieved in 98.7%. Partial or complete relief of symptoms was seen in 65% of patients. Minor complications, predominantly pain (14.3%), were seen in 26% and major complications, predominantly sepsis (3.5%), were seen in 7.9% of patients. Conclusions: These figures provide an essential benchmark for both audit and patient information. Identifying areas of good practice and those that require improvement will ultimately result in better patient care.

  5. [Interventional radiology procedures for malignancies of the liver treatment: Intraarterial procedures].

    Science.gov (United States)

    Cristina, V; Pracht, M; Lachenal, Y; Adib, S; Boubaker, A; Prior, J; Senys, A; Wagner, A D; Bize, P

    2014-05-21

    Intraarterial procedures such as chemoembolization and radioembolization aim for the palliative treatment of advanced hepatocellular carcinoma (stage BCLC B and C with tumoral portal thrombosis). The combination of hepatic intraarterial chemotherapy and systemic chemotherapy can increase the probability of curing colorectal cancer with hepatic metastases not immediately accessible to surgical treatment or percutaneous ablation.

  6. A project: 'Radiological protection in radiology', IAEA - Universidad Central de Venezuela

    International Nuclear Information System (INIS)

    Diaz, A.R.; Salazar, G.; Fermin, R.; Gonzalez, M.

    2001-01-01

    For several years a reference center of the UCV has been working on the project VEN/9/007 on dose reduction in diagnostic radiology sponsored by the IAEA. The dose and quality image was evaluated for different types of radiological study (conventional radiology, CT, mammography, interventional radiology) in different facilities at Caracas and others regions of the Venezuela. TL dosimeters were used to assess dose and reduction in dose. Based on the recommendations given by CEC documents on diagnostic quality criteria, a quality control program in radiological protection of patients and staff has been developed, for example: Pilot study by using TLD in personnel radiation monitoring. Comparative study between high and low kVp in chest. Evaluation and dose reduction in chest pediatric. Reduction of radiation dose in studies of billiards via Quality Image and reduction of the dose in studies of colon by enema. Radiation dose of staff in fluoroscopy procedures. Evaluation and dose reduction in dental radiography in public Institutions. A mammography accreditation program for Venezuela, applied to public hospitals. (author)

  7. Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).

    Science.gov (United States)

    Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B

    2018-03-15

    The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.

  8. Preliminary characterization of dose in personnel of interventional radiology; Caracterizacao preliminar da dose em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil)

    2016-07-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  9. The Changing Face of Vascular Interventional Radiology: The Future Role of Pharmacotherapies and Molecular Imaging

    International Nuclear Information System (INIS)

    Tapping, Charles R.; Bratby, Mark J.

    2013-01-01

    Interventional radiology has had to evolve constantly because there is the ever-present competition and threat from other specialties within medicine, surgery, and research. The development of new technologies, techniques, and therapies is vital to broaden the horizon of interventional radiology and to ensure its continued success in the future. In part, this change will be due to improved chronic disease prevention altering what we treat and in whom. The most important of these strategies are the therapeutic use of statins, Beta-blockers, angiotensin-converting enzyme inhibitors, and substances that interfere with mast cell degeneration. Molecular imaging and therapeutic strategies will move away from conventional techniques and nano and microparticle molecular technology, tissue factor imaging, gene therapy, endothelial progenitor cells, and photodynamic therapy will become an important part of interventional radiology of the future. This review looks at these new and exciting technologies

  10. The Changing Face of Vascular Interventional Radiology: The Future Role of Pharmacotherapies and Molecular Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, Charles R., E-mail: crtapping@doctors.org.uk; Bratby, Mark J., E-mail: mark.bratby@ouh.nhs.uk [Oxford University Hospitals, John Radcliffe Hospital, Department of Radiology (United Kingdom)

    2013-08-01

    Interventional radiology has had to evolve constantly because there is the ever-present competition and threat from other specialties within medicine, surgery, and research. The development of new technologies, techniques, and therapies is vital to broaden the horizon of interventional radiology and to ensure its continued success in the future. In part, this change will be due to improved chronic disease prevention altering what we treat and in whom. The most important of these strategies are the therapeutic use of statins, Beta-blockers, angiotensin-converting enzyme inhibitors, and substances that interfere with mast cell degeneration. Molecular imaging and therapeutic strategies will move away from conventional techniques and nano and microparticle molecular technology, tissue factor imaging, gene therapy, endothelial progenitor cells, and photodynamic therapy will become an important part of interventional radiology of the future. This review looks at these new and exciting technologies.

  11. Interventional radiological management of complications in renal transplantation

    International Nuclear Information System (INIS)

    Popovic, P.; Surlan, M.

    2004-01-01

    Background. The most frequent radiologically evaluated and treated complications in renal transplantation are perirenal and renal fluid collection and abnormalities of the vasculature and collecting system. Renal and perirenal fluid collection is usually treated successfully with percutaneous drainage. Doppler US, MRA and digital subtraction angiography (DSA) are most important in the evaluation of vascular complications of renal transplantation and management of the endovascular therapy. Conclusions. Stenosis, the most common vascular complication, occurs in 1% to 12% of transplanted renal arteries and represents a potentially curable cause of hypertension following transplantation and/or renal dysfunction. Treatment with percutaneous transluminal renal angioplasty (PTRA) or PTRA with stent has been technically successful in 82 to 92% of the cases, and graft salvage rate has ranged from 80-100%. Complications such as arterial and vein thrombosis are uncommon. Intrarenal A/V fistulas and pseudoaneurysms are occasionally seen after biopsy, the treatment requires superselective embolisation. Urologic complications are relatively uncommon; they consist predominantly of the urinary leaks and urethral obstruction. Interventional treatment consists of percutaneous nephrostomy, balloon dilation, insertion of the double J stents, metallic stent placement and external drainage of the extrarenal collections. The aim of the paper is to review the role of interventional radiology in the management of complications in renal transplantation. (author)

  12. Trends in radiology in Finland between 1995 and 2000

    International Nuclear Information System (INIS)

    Hakanen, Arvi; Jaervinen, Hannu; Soimakallio, Seppo

    2003-01-01

    The aim of this study was to demonstrate the applicability of a joint nomenclature, i.e., the examination coding system used in Finland, for making a nationwide summary of the radiological examinations and interventional procedures. Another objective was to find trends in radiological practices in Finland between 1995 and 2000 by comparing the nationwide summaries made by Radiation and Nuclear Safety Authority (STUK). An inquiry for the numbers of radiological examinations performed in 2000 was sent to 473 medical radiation users, i.e., safety license holders obtained from the registry maintained by STUK. In 2000, the proportions of plain radiography, contrast-enhanced radiography, angiography, computed tomography and radiological interventional procedures were approximately 91.1, 1.4, 0.9, 5.0, and 1.5%, respectively (distribution of medical examinations). Between 1995 and 2000, the number of medical X-ray examinations showed a slight decrease from ca. 4.2 million to ca. 4.1 million. During the investigated five years period the frequency of contrast enhanced radiography diminished ca. 50% while the frequency of computed tomography increased ca. 20%. The reported number of ultrasonographic examinations showed a slight increase to approximately 0.5 million, whereas the reported number of MRI examinations increased approximately twofold to approximately 0.1 million. The observed trends in radiological practices are useful in attempts to optimize the resources of STUK in the field of radiological protection. (orig.)

  13. [Clinical use of interventional MR imaging].

    Science.gov (United States)

    Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter

    2003-01-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.

  14. Angiography and interventional radiology of the kidneys

    International Nuclear Information System (INIS)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W.

    1999-01-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  15. Interventional radiology in the management of portal hypertension

    International Nuclear Information System (INIS)

    Punamiya, Sundeep J

    2008-01-01

    From being a mere (though important) diagnostic tool, radiology has evolved to become an integral part of therapy in portal hypertension today. Various procedures are currently available, the choice depending on the etiology and location of disease, the pathoanatomy, and the symptomatology. The main aim of any procedure is to reduce the portal pressure by either direct or indirect methods. This can be achieved with transjugular intrahepatic portosystemic shunt (TIPS), recanalization of the hepatic vein outflow, recanalization of the portal vein and its tributaries, recanalization of dysfunctional portosystemic shunts, partial splenic embolization, and embolization of arterioportal shunts. When any of these procedures cannot be performed due to anatomical or physiological reasons, the symptoms can often be controlled effectively with embolization of varices or balloon-occluded retrograde transvenous obliteration of varices (BRTO). This article briefly describes the procedures, their results, and their current status in the treatment of portal hypertension

  16. Use of Low-Fidelity Simulation Laboratory Training for Teaching Radiology Residents CT-Guided Procedures.

    Science.gov (United States)

    Picard, Melissa; Nelson, Rachel; Roebel, John; Collins, Heather; Anderson, M Bret

    2016-11-01

    To determine the benefit of the addition of low-fidelity simulation-based training to the standard didactic-based training in teaching radiology residents common CT-guided procedures. This was a prospective study involving 24 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by low-fidelity simulation-based training on three common CT-guided procedures: random liver biopsy, lung nodule biopsy, and drain placement. Baseline knowledge, confidence, and performance assessments were obtained after the didactic session and before the simulation training session. Approximately 2 months later, all residents participated in a simulation-based training session covering all three of these procedures. Knowledge, confidence, and performance data were obtained afterward. These assessments covered topics related to preprocedure workup, intraprocedure steps, and postprocedure management. Knowledge data were collected based on a 15-question assessment. Confidence data were obtained based on a 5-point Likert-like scale. Performance data were obtained based on successful completion of predefined critical steps. There was significant improvement in knowledge (P = .005), confidence (P simulation-based training to the standard didactic curriculum for all procedures. This study suggests that the addition of low-fidelity simulation-based training to a standard didactic-based curriculum is beneficial in improving resident knowledge, confidence, and tested performance of common CT-guided procedures. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Interventional Radiological Management of Prehepatic Obstruction the Splanchnic Venous System

    International Nuclear Information System (INIS)

    Semiz-Oysu, Aslihan; Keussen, Inger; Cwikiel, Wojciech

    2007-01-01

    Purpose. The purpose of this study was to retrospectively evaluate interventional radiological management of patients with symptomatic portal hypertension secondary to obstruction of splanchnic veins. Material and Methods. Twenty-four patients, 15 males and 9 females, 0.75 to 79 years old (mean, 36.4 years), with symptomatic portal hypertension, secondary to splanchnic venous obstruction, were treated by percutaneous methods. Causes and extent of splanchnic venous obstruction and methods are summarized following a retrospective evaluation. Results. Obstructions were localized to the main portal vein (n = 22), intrahepatic portal veins (n = 8), splenic vein (n = 4), and/or mesenteric veins (n = 4). Interventional treatment of 22 (92%) patients included recanalization (n = 19), pharmacological thrombolysis (n = 1), and mechanical thrombectomy (n = 5). Partial embolization of the spleen was done in five patients, in two of them as the only possible treatment. TIPS placement was necessary in 10 patients, while an existing occluded TIPS was revised in two patients. Transhepatic embolization of varices was performed in one patient, and transfemoral embolization of splenorenal shunt was performed in another. Thirty-day mortality was 13.6% (n=3). During the follow-up, ranging between 2 days and 58 months, revision was necessary in five patients. An immediate improvement of presenting symptoms was achieved in 20 patients (83%). Conclusion. We conclude that interventional procedures can be successfully performed in the majority of patients with obstruction of splanchnic veins, with subsequent improvement of symptoms. Treatment should be customized according to the site and nature of obstruction

  18. Interventional Radiological Treatment of Perihepatic Vascular Stenosis or Occlusion in Pediatric Patients After Liver Transplantation

    International Nuclear Information System (INIS)

    Uller, Wibke; Knoppke, Birgit; Schreyer, Andreas G.; Heiss, Peter; Schlitt, Hans J.; Melter, Michael; Stroszczynski, Christian; Zorger, Niels; Wohlgemuth, Walter A.

    2013-01-01

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysis (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown

  19. Characterization of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure.

    Science.gov (United States)

    Bassinet, Céline; Huet, Christelle; Baumann, Marion; Etard, Cécile; Réhel, Jean-Luc; Boisserie, Gilbert; Debroas, Jacques; Aubert, Bernard; Clairand, Isabelle

    2013-04-01

    As MOSFET (Metal Oxide Semiconductor Field Effect Transistor) detectors allow dose measurements in real time, the interest in these dosimeters is growing. The aim of this study was to investigate the dosimetric properties of commercially available TN-502RD-H MOSFET silicon detectors (Best Medical Canada, Ottawa, Canada) in order to use them for in vivo dosimetry in interventional radiology and for dose reconstruction in case of overexposure. Reproducibility of the measurements, dose rate dependence, and dose response of the MOSFET detectors have been studied with a Co source. Influence of the dose rate, frequency, and pulse duration on MOSFET responses has also been studied in pulsed x-ray fields. Finally, in order to validate the integrated dose given by MOSFET detectors, MOSFETs and TLDs (LiF:Mg,Cu,P) were fixed on an Alderson-Rando phantom in the conditions of an interventional neuroradiology procedure, and their responses have been compared. The results of this study show the suitability of MOSFET detectors for in vivo dosimetry in interventional radiology and for dose reconstruction in case of accident, provided a well-corrected energy dependence, a pulse duration equal to or higher than 10 ms, and an optimized contact between the detector and the skin of the patient are achieved.

  20. Radiation protection in the intervenmtional radiology

    International Nuclear Information System (INIS)

    Becker, Benjamin V.; Lissek, Friedrich; Waldeck, Stephan

    2017-01-01

    Interventional radiology and neuroradiology covers a variety of diagnostic and therapeutic methods. A minimal invasive percutaneous access under imaging guidance is common for all these methods. The legal regulations for quality assurance are reviewed, technical possibilities for dose reduction and the importance of modern radiation protection procedures are discussed.

  1. Variability in the Use of Simulation for Procedural Training in Radiology Residency: Opportunities for Improvement.

    Science.gov (United States)

    Matalon, Shanna A; Chikarmane, Sona A; Yeh, Eren D; Smith, Stacy E; Mayo-Smith, William W; Giess, Catherine S

    2018-03-19

    Increased attention to quality and safety has led to a re-evaluation of the classic apprenticeship model for procedural training. Many have proposed simulation as a supplementary teaching tool. The purpose of this study was to assess radiology resident exposure to procedural training and procedural simulation. An IRB-exempt online survey was distributed to current radiology residents in the United States by e-mail. Survey results were summarized using frequency and percentages. Chi-square tests were used for statistical analysis where appropriate. A total of 353 current residents completed the survey. 37% (n = 129/353) of respondents had never used procedure simulation. Of the residents who had used simulation, most did not do so until after having already performed procedures on patients (59%, n = 132/223). The presence of a dedicated simulation center was reported by over half of residents (56%, n = 196/353) and was associated with prior simulation experience (P = 0.007). Residents who had not had procedural simulation were somewhat likely or highly likely (3 and 4 on a 4-point Likert-scale) to participate if it were available (81%, n = 104/129). Simulation training was associated with higher comfort levels in performing procedures (P simulation training is associated with higher comfort levels when performing procedures, there is variable use in radiology resident training and its use is not currently optimized. Given the increased emphasis on patient safety, these results suggest the need to increase procedural simulation use during residency, including an earlier introduction to simulation before patient exposure. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Readability of informed consent forms in vascular and interventional radiology

    International Nuclear Information System (INIS)

    Pinto, I.; Vigil, D.

    1998-01-01

    To evaluate the readability of the informed consent forms prepared for vascular and interventional radiology. The 18 informed consent forms were analyzed using the Gramatica tool employed in Microsoft Word 97 For Windows which combines the statistics on legibility in terms of three sections: scores, averages and legibility (Flech index, passive voice, sentence complexity and vocabulary complexity). For each, the integrated readability index was also manually calculated. All the documents present a Flesch index of over 10; the sentence complexity indexes are less than or equal to 20, demonstrating that the sentences are not long or complicated in structure. Finally, the integrated readability index of all of them is well over 70. The forms posses acceptable legibility indexes, but their evaluation should be completed by an opinion poll of the patients for whom they are written. Moreover, it must be kept in mind that these documents, like the procedures performed, are changing continually. Thus, it is necessary to update and modify the information to be provided to the patients. (Author) 11 refs

  3. How can interventions for inhabitants be justified after a nuclear accident? An approach based on the radiological protection system of the international commission on radiological protection

    International Nuclear Information System (INIS)

    Takahara, Shogo; Homma, Toshimitsu; Yoneda, Minoru; Shimada, Yoko

    2016-01-01

    Management of radiation-induced risks in areas contaminated by a nuclear accident is characterized by three ethical issues: (1) risk trade-off, (2) paternalistic intervention and (3) individualization of responsibilities. To deal with these issues and to clarify requirements of justification of interventions for the purpose of reduction in radiation-induced risks, we explored the ethical basis of the radiological protection system of the International Commission on Radiological Protection (ICRP). The ICRP's radiological protection system is established based on three normative ethics, i.e. utilitarianism, deontology and virtue ethics. The three ethical issues can be resolved based on the decision-making framework which is constructed in combination with these ethical theories. In addition, the interventions for inhabitants have the possibility to be justified in accordance with two ways. Firstly, when the dangers are severe and far-reaching, interventions could be justified with a sufficient explanation about the nature of harmful effects (or beneficial consequences). Secondly, if autonomy of intervened-individuals can be promoted, those interventions could be justified. (author)

  4. Assessment of patients' skin dose during interventional cardiology procedures

    International Nuclear Information System (INIS)

    Tsapaki, V.; Vardalaki, E.; Kottou, S.; Molfetas, M.; Neofotistou, V.

    2002-01-01

    During the last 30 years the use of Interventional Cardiology (IC) procedures has increased significantly, mainly due to the benefits and advantages of the method that offers more accurate diagnosis and treatment along with less complications and hospitalization. However, IC procedures are based on the use of x-ray radiation, mostly localized at certain areas of patient's body and for extended periods of time. Consequently, patient may receive high radiation dose and deterministic effects, such as erythema, epilation or even dermal necrosis may be observed. Therefore, the need for reducing radiation dose is highly important. In order to achieve this, good knowledge of the dose levels delivered to the patient during IC procedures is essential since radiation effects are known to increase with dose. It is of great interest to know the point where the maximum skin dose (MSD) is noted since individual sensitivity may vary. MSDs greater than 1 Gy should be recorded. Patient dosimetry during IC procedures is a complex task since these type of procedures depend on various factors, such as complexity and severity of case, different specifications of x-ray equipment and patient's physical characteristics. Moreover, cardiologist's experience plays an important role. For these reasons, Food and Drug Administration (FDA), the International Commission on Radiological Protection (ICRP) as well as the World Health Organization (WHO), have published documents on radiation safety and ways to reduce skin injuries during IC procedures. Various methods have been proposed for measuring MSD such as the use of slow radiotherapy films, thermoluminescent detectors (TLD), scintillation detectors, Dose-Area Product (DAP) meter, as well as a combination of DAP and air kerma. A literature review on MSDs measured during IC procedures showed that doses ranged from 300 to 43000 mGy

  5. Criteria and actions facing a radiological environmental contamination

    International Nuclear Information System (INIS)

    Gutierrez, Jose; Montero, Milagros

    2008-01-01

    An approach to improve the management of the radiological risk due to an environmental contamination is presented. The experience gained in emergency response has clearly demonstrated the importance to have an efficient emergency system including planning, procedures and operational internally consistent criteria. The lack of these components in the emergency system could lead to important radiological and non radiological consequences. The setting of internationally agreed criteria and guides is very important in the anticipated emergency response plan. The paper firstly reviews the approaches proposed by international recommendations and norms. From this review, a substantial coincidence on the basic principles is stated, in spite of small differences in its formulation. Also, a need for harmonization is endorsed. So, generic levels, in terms of imparted dose or avoided dose due to intervention, and, in some cases, derived levels, in terms of activity concentration, are proposed. Numerical values for emergency actions are also identified. The second part deals with the adaptation of the existing prediction and decision systems to the above radiological criteria. Relations among deposition, activity concentrations and annual doses for different scenarios, exposure pathways and age groups are established. Also, the sensibility of the radiological impact against different characteristics of the intervention scenarios is stated. This makes easy to assess the radiological significance of different contamination situations by comparison to the existing action generic levels. Furthermore, the radiological impact can be numerically incorporated in a decision system which includes non radiological aspects of the applicable intervention options. Agricultural, urban and mixed scenarios are presented and solved for a 137 Cs contamination. The results can be further used to develop a methodology guide for setting action generic levels in post-accidental interventions and

  6. Individual monitoring of medical staff working in interventional radiology in Switzerland using double dosimetry

    International Nuclear Information System (INIS)

    Damet, J.; Bailat, C.; Bize, P.; Buchillier, Th.; Tosic, M.; Verdun, F.R.; Baechler, S.

    2011-01-01

    Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

  7. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    International Nuclear Information System (INIS)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion

  8. Determining and managing fetal radiation dose from diagnostic radiology procedures in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Ozbayrak, Mustafa; Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa [Istanbul University, Istanbul (Turkmenistan)

    2015-12-15

    We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion.

  9. ERRAPRI Project: estimation of radiation risk to patients in interventional radiology, initial results and proposed levels of complexity; Proyecto ERRAPRI: estimacion del riesgo radiologico a los pacientes en radiologia intervencionista. Primeros resultados y propuestas de indices de complejidad

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Cruces, R.; Vano, E.; Hernandez-Armas, J.; Carrera, F.; Diaz, F.; Gallego Beuther, J. F.; Ruiz Munoz-Canela, J. P.; Sanchez Casanueva, R.; Perez Martinez, M.; Fernandez Soto, J. M.; Munoz, V.; Moreno, F.; Moreno, C.; Martin-Palanca, A.

    2011-07-01

    The project ERRAPRI (2009 - 2012) will assess the most relevant aspects of the radiological risk associated with interventional radiology techniques (IR) guided by fluoroscopy in a sample of Spanish hospitals of three autonomous regions. Specific objectives include: assessing procedural protocols, especially the parameters related to radiation dose and diagnostic information obtained to establish balances cost (radiation risk) benefit to the procedures evaluated, and propose an index of complex procedures on several levels, based on the difficulty of making the same, assessing its relationship with the radiation dose values.

  10. Broken Esophageal Stent Successfully Treated by Interventional Radiology Technique

    International Nuclear Information System (INIS)

    Zelenak, Kamil; Mistuna, Dusan; Lucan, Jaroslav; Polacek, Hubert

    2010-01-01

    Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated with the interventional radiology technique, whereby a second implantation of the esophageal stent was carried out quite successfully.

  11. PACS for surgery and interventional radiology: features of a Therapy Imaging and Model Management System (TIMMS).

    Science.gov (United States)

    Lemke, Heinz U; Berliner, Leonard

    2011-05-01

    Appropriate use of information and communication technology (ICT) and mechatronic (MT) systems is viewed by many experts as a means to improve workflow and quality of care in the operating room (OR). This will require a suitable information technology (IT) infrastructure, as well as communication and interface standards, such as specialized extensions of DICOM, to allow data interchange between surgical system components in the OR. A design of such an infrastructure, sometimes referred to as surgical PACS, but better defined as a Therapy Imaging and Model Management System (TIMMS), will be introduced in this article. A TIMMS should support the essential functions that enable and advance image guided therapy, and in the future, a more comprehensive form of patient-model guided therapy. Within this concept, the "image-centric world view" of the classical PACS technology is complemented by an IT "model-centric world view". Such a view is founded in the special patient modelling needs of an increasing number of modern surgical interventions as compared to the imaging intensive working mode of diagnostic radiology, for which PACS was originally conceptualised and developed. The modelling aspects refer to both patient information and workflow modelling. Standards for creating and integrating information about patients, equipment, and procedures are vitally needed when planning for an efficient OR. The DICOM Working Group 24 (WG-24) has been established to develop DICOM objects and services related to image and model guided surgery. To determine these standards, it is important to define step-by-step surgical workflow practices and create interventional workflow models per procedures or per variable cases. As the boundaries between radiation therapy, surgery and interventional radiology are becoming less well-defined, precise patient models will become the greatest common denominator for all therapeutic disciplines. In addition to imaging, the focus of WG-24 is to serve

  12. PACS for surgery and interventional radiology: Features of a Therapy Imaging and Model Management System (TIMMS)

    International Nuclear Information System (INIS)

    Lemke, Heinz U.; Berliner, Leonard

    2011-01-01

    Appropriate use of information and communication technology (ICT) and mechatronic (MT) systems is viewed by many experts as a means to improve workflow and quality of care in the operating room (OR). This will require a suitable information technology (IT) infrastructure, as well as communication and interface standards, such as specialized extensions of DICOM, to allow data interchange between surgical system components in the OR. A design of such an infrastructure, sometimes referred to as surgical PACS, but better defined as a Therapy Imaging and Model Management System (TIMMS), will be introduced in this article. A TIMMS should support the essential functions that enable and advance image guided therapy, and in the future, a more comprehensive form of patient-model guided therapy. Within this concept, the 'image-centric world view' of the classical PACS technology is complemented by an IT 'model-centric world view'. Such a view is founded in the special patient modelling needs of an increasing number of modern surgical interventions as compared to the imaging intensive working mode of diagnostic radiology, for which PACS was originally conceptualised and developed. The modelling aspects refer to both patient information and workflow modelling. Standards for creating and integrating information about patients, equipment, and procedures are vitally needed when planning for an efficient OR. The DICOM Working Group 24 (WG-24) has been established to develop DICOM objects and services related to image and model guided surgery. To determine these standards, it is important to define step-by-step surgical workflow practices and create interventional workflow models per procedures or per variable cases. As the boundaries between radiation therapy, surgery and interventional radiology are becoming less well-defined, precise patient models will become the greatest common denominator for all therapeutic disciplines. In addition to imaging, the focus of WG-24 is to serve

  13. Quality assurance measures in interventional radiology

    International Nuclear Information System (INIS)

    Heuser, L.

    1999-01-01

    The quality assurance of treatment measures is legally required but as yet not generally established in practice. For interventional radiology, the introduction of quality assurance for PTA of arteries of the lower limbs is planned for January 1999. It is reasonable to subject at least the most important and/or most frequently performed interventions to quality management. In the present article, the term quality in the management of diseases is defined and the system of total quality management discussed at the levels structure, process, and results. For its application, parameters of quality measurement in the form of standards, criteria, and characteristic values are necessary and must be laid down by a team of experts on the basis of subjective experience and/or results in the literature. Practical quality assurance takes place not only within a clinic but also externally by comparison with other centers. Data collection and evaluation requires high-performance software that will be continuously improved, expanded, and adapted to current needs during regular meetings between the various users. (orig.) [de

  14. Procedures manual for the ORNL Radiological Survey Activities (RASA) Program

    International Nuclear Information System (INIS)

    Myrick, T.E.; Berven, B.A.; Cottrell, W.D.; Goldsmith, W.A.; Haywood, F.F.

    1987-04-01

    The portion of the radiological survey program performed by ORNL is the subject of this Procedures Manual. The RASA group of the Health and Safety Research Division (HASRD) at ORNL is responsible for the planning, conducting, and reporting of the results of radiological surveys at specified sites and associated vicinity properties. The results of these surveys are used by DOE in determining the need for and extent of remedial actions. Upon completion of the necessary remedial actions, the ORNL-RASA group or other OOS contractor may be called upon to verify the effectiveness of the remedial action. Information from these postremedial action surveys is included as part of the data base used by DOE in certifying a site for unrestricted use

  15. Procedures manual for the ORNL Radiological Survey Activities (RASA) Program

    Energy Technology Data Exchange (ETDEWEB)

    Myrick, T.E.; Berven, B.A.; Cottrell, W.D.; Goldsmith, W.A.; Haywood, F.F.

    1987-04-01

    The portion of the radiological survey program performed by ORNL is the subject of this Procedures Manual. The RASA group of the Health and Safety Research Division (HASRD) at ORNL is responsible for the planning, conducting, and reporting of the results of radiological surveys at specified sites and associated vicinity properties. The results of these surveys are used by DOE in determining the need for and extent of remedial actions. Upon completion of the necessary remedial actions, the ORNL-RASA group or other OOS contractor may be called upon to verify the effectiveness of the remedial action. Information from these postremedial action surveys is included as part of the data base used by DOE in certifying a site for unrestricted use.

  16. The combined application of radiology, nuclear medicine and fine needle aspiration biopsy cytology (FNAB)

    International Nuclear Information System (INIS)

    Cardozo, P.L.; Ruis, I.A.M.

    1980-01-01

    The combination of diagnostic cytology and diagnostic radiology, including intervention radiology, is a logical one. Radiology can visualize lesions which cannot be found otherwise and under its guidance cytology can obtain a direct and usually diagnostic proof of the true nature of the process with minimal inconvenience and risk for the patient. A survey of the combination of cytology and radiological procedures in the diagnosis work-up is outlined. (Auth.)

  17. Interventional radiology in pediatric oncology

    International Nuclear Information System (INIS)

    Hoffer, Fredric A.

    2005-01-01

    There are many radiological interventions necessary for pediatric oncology patients, some of which may be covered in other articles in this publication. I will discuss a number of interventions including percutaneous biopsy for solid tumor and hematological malignancy diagnosis or recurrence, for the diagnosis of graft versus host disease after stem cell or bone marrow transplantation, and for the diagnosis of complications of immunosuppression such as invasive pulmonary aspergillosis. In the past, tumor localization techniques have been necessary to biopsy or resect small lesions. However improved guidance techniques have allowed for more precise biopsy and the use of thermal ablation instead of excision for local tumor control. A percutaneously placed radio frequency, microwave, laser or cryogen probe can ablate the primary and metastatic tumors of the liver, lung, bone, kidney and other structures in children. This is an alternative treatment for the local control of tumors that may not be amenable to surgery, chemotherapy or radiotherapy. I will also describe how chemoembolization can be used to treat primary or metastatic tumors of the liver that have failed other therapies. This treatment delivers chemotherapy in the hepatic artery infused with emboli to increase the dwell time and concentration of the agents

  18. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  19. Needlestick Injuries in Interventional Radiology Are Common and Underreported.

    Science.gov (United States)

    Deipolyi, Amy R; Prabhakar, Anand M; Naidu, Sailendra; Oklu, Rahmi

    2017-12-01

    Purpose To determine the prevalence of and risk factors for needlesticks in interventional radiology physicians, as well as the attitudes, behaviors, and conditions that promote or interfere with reporting of these injuries. Materials and Methods A total of 3889 interventional radiologists from academic and private practice in the United States were surveyed by emailing all interventional radiologist members of the Society of Interventional Radiology, including attending-level physicians and trainees (April-August 2016). The institutional review board waived the need for consent. Questions inquired about the nature, frequency, and type of needlestick and sharps injuries and whether and to whom these incidents were reported. Stepwise regression was used to determine variables predicting whether injuries were reported. Results In total, 908 (23%) interventional radiologists completed at least a portion of the survey. Eight hundred fourteen (91%) of 895 respondents reported a prior needlestick injury, 583 (35%) of 895 reported at least one injury while treating an HIV-positive patient, and 626 (71%) of 884 reported prior training regarding needlestick injury. There was, on average, one needlestick for every 5 years of practice. Most needlestick or sharps injuries were self inflicted (711 [87%] of 817) and involved a hollow-bore device (464 [56%] of 824). Only 566 (66%) of 850 injuries were reported. The most common reasons for not reporting included perceived lack of utility of reporting (79 [28%] of 282), perceived low risk for injury (56 [20%] of 282), noncontaminated needle (53 [19%] of 282), too-lengthy reporting process (37 [13%] of 282), and associated stigma (23 [8%] of 282). Only 156 (25%) of 624 respondents informed their significant other. Stepwise regression assessing variables affecting the likelihood of reporting showed that male sex (P = .009), low-risk patient (P < .0001), self injury (P = .010), trainee status (P < .0001), and the total number of prior

  20. Vascular Closure Devices in Interventional Radiology Practice

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [John Radcliffe Hospital, Department of Radiology (United Kingdom); Muller-Hulsbeck, Stefan, E-mail: muehue@diako.de [Diakonissen Hospital, Diagnostic and Interventional Radiology/Neuroradiology (Germany); Morgan, Robert, E-mail: robert.morgan@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom); Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk [John Radcliffe Hospital, Department of Radiology (United Kingdom)

    2015-08-15

    Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants are used. There are a variety of vascular closure devices (VCDs) available to overcome these limitations. This review gives an overview of current VCDs, their mechanism of action, individual strengths and weaknesses, evidence base and utility in interventional radiology (IR) practice. The majority of the published evidence on VCDs is derived from patients undergoing cardiac interventions, which should be borne in mind when considering the applicability and transfer of this data for general IR practice. Overall, the evidence suggests that most VCDs are effective in achieving haemostasis with a similar rate of complications to MC although the complication profile associated with VCDs is distinct to that of MC. There is insufficient evidence to comparatively analyse the different types of VCDs currently available or reliably judge their cost-effectiveness. The interventional radiologist should have a thorough understanding of the available techniques for haemostasis and be able to identify and utilise the most appropriate strategy and closure technique for the individual patient.

  1. Derivation of Intervention levels for Protection of the Public in a Radiological Emergency in Korea

    International Nuclear Information System (INIS)

    Lee, Jong Tai; Lee, Goan Yup; Khang, Byung Oui; Oh, Ki Hoon; Kim, Chang Kyu

    2001-01-01

    Intervention levels for protection of the public in a radiological emergency are theoretically derived by the cost-benefit approach with the concept of justification and optimization. Intervention levels on the sheltering, evacuation, temporary relocation and permanent resettlement for protection of the public are estimated with the cost to protective countermeasures and the value from dose averted which are the site specific parameters. As a result, it is confirmed that IAEA guidelines for intervention levels are applicable to the radiological emergency in Korea. Optimum ranges of 5 - 10 mSv/2days for sheltering, 25 - 130 mSv/week for evacuation, 15 - 90 mSv/month for temporary relocation and 600 - 3,500 mSv/lifetime for permanent resettlement for intervention levels are also provided. The result can be applied as useful data to update intervention levels under the theoretical background in Korea

  2. Radiological protection in medicine: work of ICRP Committee 3

    International Nuclear Information System (INIS)

    Vañó, E.; Cosset, J.M.; Rehani, M.M.

    2012-01-01

    Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with protection in medicine, and develops recommendations and guidance on the protection of patients, staff, and the public against radiation exposure in medicine. This paper presents an overview of the work of Committee 3 over recent years, and the work in progress agreed at the last annual meeting in Bethesda, MD in October 2011. The reports published by ICRP dealing with radiological protection in medicine in the last 10 years cover topics on: education and training in radiological protection; preventing accidental exposures in radiation therapy; dose to patients from radiopharmaceuticals; radiation safety aspects of brachytherapy; release of patients after therapy with unsealed radionuclides; managing patient dose in digital radiology and computed tomography; avoidance of radiation injuries from medical interventional procedures; pregnancy and medical radiation; and diagnostic reference levels in medical imaging. Three new reports will be published in the coming months dealing with aspects of radiological protection in fluoroscopically guided procedures outside imaging departments; cardiology; and paediatric radiology. The work in progress agreed by Committee 3 is also described.

  3. Review the past and look forward the future: in celebration of 20 anniversary of(Chinese Society of Interventional Radiology)

    International Nuclear Information System (INIS)

    Li Linsun

    2010-01-01

    This paper aims to make a brief review of the Chinese Society of Interventional Radiology in the past 20 years since it was established and to put forward some personal suggestions. The article will mainly describe the following contents: (1) to make suggestions to set up a standard organization of Chinese Interventional Society; (2) to demand interventional radiologist to be a real clinical doctor, to take care of their own patients for full course, to practice all kinds of minimally-invasive therapy; (3) to improve the ability of scientific research work; (4) to perfect the system of education, training and promotion in interventional radiology field; (5) to strengthen the special team of interventional radiologists; (6) to raise the academic level and status of the 'Journal of Interventional Radiology'; (7) to heighten the quality of academic activity and to intensify the organization system of interventional discipline; (8) to correctly deal with the competition between different subjects; and (9) to improve and perfect our own interventional job.(authors)

  4. Radiological interventional procedures for the acute abdomen

    International Nuclear Information System (INIS)

    Trumm, C.; Hoffmann, R.T.; Reiser, M.F.

    2010-01-01

    In patients with acute thrombo-embolic occlusion of the superior mesenteric artery, catheter-assisted thrombolytic therapy represents a procedure of increasing importance in addition to surgery and intensive care treatment. The thrombolytic drugs utilized for this purpose are urokinase, streptokinase and recombinant tissue plasminogen activator (rtPA). Therapeutic embolization is predominantly used in the treatment of arterial bleeding from the gastro-intestinal tract, the liver, the intestines (due to an aneurysm or vascular malformation) and in bleeding from intestinal anastomoses. Polyvinyl alcohol particles, embospheres, gelfoam and microcoils can be utilized as embolic agents. Percutaneous transhepatic cholangiodrainage and stent implantation are applied in patients with biliary obstructions caused by inoperable tumors of the gall bladder or bile ducts, of the pancreatic head or duodenum and by metastases located in the liver parenchyma or hepatic hilum. Image-guided percutaneous drainage is a valuable option in the management of abscesses in the peritoneal cavity; less common indications are lymphoceles, biliomas, urinomas, hematomas, necrosis and pseudocysts. (orig.) [de

  5. Development of a Real-time Hand Dose Monitor for Personnel in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ban, N.; Nakaoka, H.; Haruta, R.; Murakami, Y.; Kubo, T.; Maeda, T.; Kusama, T

    2001-07-01

    Medical procedures denoted as interventional radiology require operation near an X ray beam, which brings high dose exposures to the operators' hands. For the effectual control of their extremity doses, a prototype of a real-time wrist dosemeter has been developed, hand dose monitor (HDM), based on a single silicon detector. Experiments were performed to test its response to diagnostic X rays. The HDM was highly sensitive and showed a linear response down to doses of a few tens of microsieverts. Though dose rate, energy and angular dependence of the response were observed in some extreme conditions, the HDM was proved to be of practical use if it was appropriately calibrated. Since an HDM enables personnel to check their hand doses on a real-time basis, it would enable medical staff to control the exposure themselves. (author)

  6. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    International Nuclear Information System (INIS)

    Uberoi, Raman; Tapping, Charles Ross; Chalmers, Nicholas; Allgar, Victoria

    2013-01-01

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate ( 9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up

  7. Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures

    International Nuclear Information System (INIS)

    Zuguchi, M.; Chida, K.; Taura, M.; Inaba, Y.; Ebata, A.; Yamada, S.

    2008-01-01

    At present, interventional radiology (IVR) tends to involve long procedures (long radiation duration), and physicians are near to the source of scattered radiation. Hence, shielding is critical in protecting physicians from radiation. Protective aprons and additional lead-shielding devices, such as table-side lead drapes, are important means of protecting the physician from scattered radiation. The purpose of this study was to evaluate whether non-lead aprons are effective in protecting physicians from radiation during IVR procedures. In this study, the radiation protection effects of commercially available protective lead and non-lead aprons, when exposed to diagnostic X rays, are compared. The performance of these non-lead and lead aprons was similar for scattered X rays at tube voltages of 60-120 kV. Properly designed non-lead aprons are thus more suitable for physicians because they weigh ∼20% less than the lead aprons, and are non-toxic. (authors)

  8. Lean manufacturing and Toyota Production System terminology applied to the procurement of vascular stents in interventional radiology.

    Science.gov (United States)

    de Bucourt, Maximilian; Busse, Reinhard; Güttler, Felix; Wintzer, Christian; Collettini, Federico; Kloeters, Christian; Hamm, Bernd; Teichgräber, Ulf K

    2011-08-01

    OBJECTIVES: To apply the economic terminology of lean manufacturing and the Toyota Production System to the procurement of vascular stents in interventional radiology. METHODS: The economic- and process-driven terminology of lean manufacturing and the Toyota Production System is first presented, including information and product flow as well as value stream mapping (VSM), and then applied to an interdisciplinary setting of physicians, nurses and technicians from different medical departments to identify wastes in the process of endovascular stent procurement in interventional radiology. RESULTS: Using the so-called seven wastes approach of the Toyota Production System (waste of overproducing, waiting, transport, processing, inventory, motion and waste of defects and spoilage) as well as further waste characteristics (gross waste, process and method waste, and micro waste), wastes in the process of endovascular stent procurement in interventional radiology were identified and eliminated to create an overall smoother process from the procurement as well as from the medical perspective. CONCLUSION: Economic terminology of lean manufacturing and the Toyota Production System, especially VSM, can be used to visualise and better understand processes in the procurement of vascular stents in interventional radiology from an economic point of view.

  9. Recommendations for intervention

    International Nuclear Information System (INIS)

    Touzet, R.; Descalzo, A.; Peralta, O.

    2013-01-01

    The objective of this work is set a 'radiological protection criteria' for patients and staff involved for the purpose of the doses involved are as low as reasonably achievable considering the limitations that each technique and its objectives. Establish criteria for injury prevention in the patient's skin for long exposures and intense when complications arise in the process. Set levels for some well Dimensional procedures. Establish procedures for patient dosimetry control and operator personnel. These criteria will be established by the interventional radiology team with participation of specialists in radiation protection, medical physics, dosimetry and X rays equipment specialists

  10. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  11. Should there be greater exposure to interventional radiology in the undergraduate curriculum?

    Science.gov (United States)

    Ojha, Utkarsh; Mohammed, Raihan; Vivekanantham, Sayinthen

    2017-01-01

    Medical imaging has been one of the most revolutionary innovations in medicine. Today, as health care professionals shift their focus toward more sophisticated technology and minimally invasive procedures, interventional radiology (IR) has become a rapidly expanding specialty. Despite these advances, there is a lack of doctors specializing in this field. A growing body of evidence suggests that the low number of applicants for posts may be due to poor exposure to the specialty at medical school. In this article, we outline the importance of IR in today's health care system. Next, we evaluate the evidence that there is a lack of knowledge of IR not only among medical students in the UK but globally. We further discuss how a more effective incorporation of IR in the undergraduate curriculum can enhance medical students' interest in the field and subsequently increase the number of doctors specializing in IR. Finally, we suggest alternative strategies to gauge medical students' interest in IR, including teaching via e-learning and virtual reality.

  12. Mortality reporting in interventional radiology: Experience of a pilot audit with the Scottish Audit of Surgical Mortality

    International Nuclear Information System (INIS)

    White, R.D.; Ingram, S.; Moss, J.G.; Pace, N.; Chakraverty, S.

    2013-01-01

    Aim: To describe the initial pilot phase of the 2009 Scottish Audit of Surgical Mortality (SASM), which includes outcomes and difficulties that arose during any interventional radiology (IR) procedure performed on patients in this audit over an 18 month period. Materials and methods: Approximately 40 consultant interventional radiologists from all units in Scotland elected to participate in the audit. Each response was then peer reviewed after anonymisation of the patient and institution. If a relevant ACON (area for consideration or area of concern) was generated, this was checked by one of the other reviewers before communication with the original reporting radiologist and colleagues. There was then a right of reply by the reporting unit before formal documentation was sent out. Results: Initial results were analysed after 18 months period, during which time 95 forms relating to deaths of surgical inpatients were sent to interventional radiologists identified as having been involved in an IR procedure at some time during the patient’s admission. Seventy-one forms had been returned by July 2010, of which 46 had gone through the entire SASM process. From these, 10 ACONs were attributed. Anonymised case vignettes and reports from these were used as educational tools. Conclusion: Involvement with SASM is a useful process. Significant safety issues and learning points were identified in the pilot. The majority of ACONs identified by the audit were in patients who had undergone percutaneous biliary interventions

  13. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  14. Study on generic intervention levels for protecting the public in a nuclear accident or radiological emergency

    International Nuclear Information System (INIS)

    Suzuki, Fabio Fumio

    2003-01-01

    After a nuclear accident or radiological emergency, several social and economical factors shall be considered for the actions to protect the public and to recover the environment. The application of the radiological protection principles on practices in intervention situations may lead to adoption of protective measures disproportional to the involved risk, compromising the resources available to more effective actions. This causes a negative impact on the population and may conduct to discredit about the protective measures and the lost of confidence on the authorities. In this context, the principles of radiological protection for interventions should be studied and analyzed for being adequately applied in accident situations or radiological emergencies that involves the country. These principles are constantly improved and the concept of generic intervention level plays an important role in the decision-making to protect the public. The costs involved to the protective measures for the public in Brazil were studied and cost benefit analysis techniques were applied to estimate the generic intervention levels for public protection applicable in the country. These results were compared to those values internationally recommended, as well to values obtained in a similar study accomplished for Japan. It was also performed a sensibility analysis of the results regarding a value and a simple analysis of the results considering the costs of the several protective measures. (author)

  15. Dosimetry in diagnostic and interventional radiology - ICRU and IAEA activities

    International Nuclear Information System (INIS)

    Zoetelief, J.; Pernicka, F.

    2002-01-01

    Full text: Main aims of patient dosimetry in diagnostic and interventional radiology are to determine dosimetric quantities for establishment and use of guidance levels or diagnostic reference levels and for comparative risk assessment. In the latter case, the average doses to the organs and tissues at risk should be assessed. Only limited number of measurements serve to potential risk assessment of the examination and intervention. An additional objective of dosimetry in diagnostic and interventional radiology is the assessment of equipment performance. Ionization chambers are the main devices used for dosimetric measurements in diagnostic and interventional radiology but other devices with special properties are also used. Important examples are thermoluminescent detectors (TLDs) and semiconductor detectors. For most dosemeters used in x-ray medical imaging the desired quantity for calibration of dosemeters is the air kerma free-in-air. Calibrations should be made at appropriate radiation qualities, for which recommendations are available for conventional radiology. It is important that the calibrations are traceable to the international measurement system. The uncertainty of dose measurements in medical x-ray imaging, for comparative risk assessments as well as for quality assurance, should not exceed about 7 per cent in terms of the expanded uncertainty using a coverage factor of 2. The dosimetric approaches in general diagnostic radiology, mammography and computed tomography are slightly different, resulting in application specific dosimetric quantities. Consequently, different protocols for patient dosimetry are available for these different purposes. In general diagnostic radiology, various quantities and terminologies have been used for the specification of dose on the central beam axis at the point where the x-ray beam enters the patient (or a phantom representing the patient). These include the exposure at skin entrance (ESE), the input radiation exposure

  16. Radiological safety for the public during nuclear emergencies: application of intervention levels and derived intervention levels

    International Nuclear Information System (INIS)

    Thomas, G.; Kumar, K.S.

    2006-01-01

    public from a practice is relatively small, the intervention level based on averted dose may have to be high, as significant reduction in exposure is required to justify the intervention. For intervention after a major nuclear / radiological accident, the non-radiological risk could be much larger, particularly if it is necessary to evacuate a large number of people. The variation between intervention levels for different nuclear/ radiological emergency situation could also differ quite significantly. In case of intervention, the doses received before the countermeasures are implemented should not be counted for balancing the detriment and benefit as these doses will be received whether or not the intervention is carried out. At the same time, applying the concept of averted dose involves lot of uncertainty in predicting and advising the time of intervention. The initial planning for various emergencies should include a choice of intervention levels, as discussed in this paper, in terms of averted doses, that will be justified and reasonably well optimized. Each protective action should therefore be considered on its own merits and the doses that would be incurred via all relevant pathways of exposure should also be assessed. (authors)

  17. Computer-based information management system for interventional radiology

    International Nuclear Information System (INIS)

    Forman, B.H.; Silverman, S.G.; Mueller, P.R.; Hahn, P.F.; Papanicolaou, N.; Tung, G.A.; Brink, J.A.; Ferrucci, J.T.

    1989-01-01

    The authors authored and implemented a computer-based information management system (CBIMS) for the integrated analysis of data from a variety of abdominal nonvascular interventional procedures. The CBIMS improved on their initial handwritten-card system (which listed only patient name, hospital number, and type of procedure) by capturing relevant patient data in an organized fashion and integrating information for meaningful analysis. Advantages of CBIMS include enhanced compilation of monthly census, easy access to a patient's interventional history, and flexible querying capability that allows easy extraction of subsets of information from the patient database

  18. The Interventional Radiology (IR) Gender Gap: A Prospective Online Survey by the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).

    Science.gov (United States)

    Wah, Tze Min; Belli, Anna Maria

    2018-05-22

    A prospective online survey was conducted by the Cardiovascular Interventional Radiological Society of Europe (CIRSE) to evaluate the gender gap within interventional radiology (IR) and the barriers facing women in IR. A questionnaire ("Appendix") was devised by the authors and the CIRSE communication and publication team and sent electronically to 750 identifiable female members of CIRSE. Responses were collected from 7 August to 24 August 2017. The response rate was 19.9% (n = 149) with highest responses from UK (18%), Italy (11%), Germany (11%), Spain (7%), Netherlands (5%), France (5%), Sweden (4%), USA (4%). 91% of the respondents were between 31 and 46 years, 83% work full time, 62% spend > 50% of their working time in IR, and 67% practice in a university or tertiary referral institution. 85% were in the minority in their department. 52% had no leadership role in their department, but 67% expressed willingness to consider a leadership position. Their main concerns were work/family life balance, the risks of radiation exposure, the effect of pregnancy on training and practice and the male-dominated work environment. This survey highlights issues experienced by women in IR. Clear guidance on concerns regarding radiation exposure particularly during pregnancy is needed. Structured and supportive training is required for female IRs who may wish to train or work flexibly. The male-dominated environment is discouraging, and a scheme to promote female IRs would encourage women to take on senior leadership positions and attract more women into the specialty.

  19. Health literacy in vascular and interventional radiology: a comparative analysis of online patient education resources.

    Science.gov (United States)

    Hansberry, David R; Kraus, Carl; Agarwal, Nitin; Baker, Stephen R; Gonzales, Sharon F

    2014-08-01

    The Internet is frequently accessed by patients as a resource for medical knowledge. However, the provided material is typically written at a level well above the recommended 7th grade level. A clear understanding of the capabilities, limitations, risks, and benefits of interventional radiology by patients, both current and prospective, is hindered when the textual information offered to the public is pitched at a level of sophistication too high for general comprehension. In January 2013, all 25 patient education resources from the Cardiovascular and Interventional Radiology Society of Europe (CIRSE) Web site ( http://www.cirse.org ) and all 31 resources from the Society of Interventional Radiology (SIR) Web site ( http://www.sirweb.org ) were analyzed for their specific level of readability using ten quantitative scales: Flesch Reading Ease, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning fog index, New Fog Count, Coleman-Liau index, FORCAST formula, Fry graph, Raygor Readability Estimate, and New Dale-Chall. Collectively, the patient education resources on the CIRSE Web site are written at the 12.3 grade level, while the resources on the SIR Web site are written at the 14.5 grade level. Educational health care materials available on both the CIRSE and the SIR Web sites are presented in language in the aggregate that could be too difficult for many lay people to fully understand. Given the complex nature of vascular and interventional radiology, it may be advantageous to rewrite these educational resources at a lower reading level to increase comprehension.

  20. A framework for the evaluation of new interventional procedures.

    Science.gov (United States)

    Lourenco, Tania; Grant, Adrian M; Burr, Jennifer M; Vale, Luke

    2012-03-01

    The introduction of new interventional procedures is less regulated than for other health technologies such as pharmaceuticals. Decisions are often taken on evidence of efficacy and short-term safety from small-scale usually observational studies. This reflects the particular challenges of evaluating interventional procedures - the extra facets of skill and training and the difficulty defining a 'new' technology. Currently, there is no framework to evaluate new interventional procedures before they become available in clinical practice as opposed to new pharmaceuticals. This paper proposes a framework to guide the evaluation of a new interventional procedure. A framework was developed consisting of a four-stage progressive evaluation for a new interventional procedure: Stage 1: Development; Stage 2: Efficacy and short-term safety; Stage 3: Effectiveness and cost-effectiveness; and Stage 4: Implementation. The framework also suggests the types of studies or data collection methods that can be used to satisfy each stage. This paper makes a first step on a framework for generating evidence on new interventional procedures. The difficulties and limitations of applying such a framework are discussed. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Antiplatelet and Anticoagulant Drugs in Interventional Radiology

    International Nuclear Information System (INIS)

    Altenburg, Alexander; Haage, Patrick

    2012-01-01

    In treating peripheral arterial disease, a profound knowledge of antiplatelet and anticoagulative drug therapy is helpful to assure a positive clinical outcome and to anticipate and avoid complications. Side effects and drug interactions may have fatal consequences for the patient, so interventionalists should be aware of these risks and able to control them. Aspirin remains the first-line agent for antiplatelet monotherapy, with clopidogrel added where dual antiplatelet therapy is required. In case of suspected antiplatelet drug resistance, the dose of clopidogrel may be doubled; prasugrel or ticagrelor may be used alternatively. Glycoprotein IIb/IIIa inhibitors (abciximab or eptifibatide) may help in cases of hypercoagulability or acute embolic complications. Desmopressin, tranexamic acid, or platelet infusions may be used to decrease antiplatelet drug effects in case of bleeding. Intraprocedurally, anticoagulant therapy treatment with unfractionated heparin (UFH) still is the means of choice, although low molecular-weight heparins (LMWH) are suitable, particularly for postinterventional treatment. Adaption of LMWH dose is often required in renal insufficiency, which is frequently found in elderly patients. Protamine sulphate is an effective antagonist for UFH; however, this effect is less for LMWH. Newer antithrombotic drugs, such as direct thrombin inhibitors or factor X inhibitors, have limited importance in periprocedural treatment, with the exception of treating patients with heparin-induced thrombocytopenia (HIT). Nevertheless, knowing pharmacologic properties of the newer drugs facilitate correct bridging of patients treated with such drugs. This article provides a comprehensive overview of antiplatelet and anticoagulant drugs for use before, during, and after interventional radiological procedures.

  2. Review of interventional procedures in the very low birth-weight infant (<1.5 kg): complications, lessons learned and current practice

    Energy Technology Data Exchange (ETDEWEB)

    Laffan, Eoghan E. [Children' s Hospital of Eastern Ontario, Department of Diagnostic Imaging, Ottawa, ON (Canada); McNamara, Patrick J.; Whyte, Hilary; L' Herault, Johanne [The Hospital for Sick Children, Division of Neonatology, Toronto, ON (Canada); Amaral, Joao; Temple, Michael; John, Philip; Connolly, Bairbre L. [The Hospital for Sick Children, The Image-Guided Therapy Unit, Toronto, ON (Canada)

    2009-08-15

    Interventional radiology (IR) procedures in very low birth-weight (VLBW) infants (<1.5 kg) are challenging due to size, immaturity, comorbidities and lack of devices of suitable size. Infants are moved from the neonatal intensive care unit to the IR suite, further exposing them to risk. Our purpose was to review our experience of interventional procedures in VLBW infants, specifically complications and potential risks. VLBW infants referred for image-guided therapy between 1998 and 2005 were identified and medical records reviewed. ''Complications'' were divided into: major or minor, periprocedural or postprocedural, and intervention-/device-related, patient-related or equipment-related. Transport risk index of physiological stability (TRIPS) scores were calculated. A total of 116 infants (68 male, 48 female) underwent 176 procedures (159 vascular access-related and 17 nonvascular). Of 158 complications identified, 116 were major and 42 were minor. Major complications included hypothermia (n=33), line manipulations/removals (n=25), bleeding (n=12), thrombosis (n=4), cardiac arrest (n=3), tamponade (n=2), and multiorgan failure (n=1). Of the complications, 119 were categorized as intervention-/device-related, 32 patient-related and 7 equipment-related. There were no significant differences between pre- and postprocedural TRIPS scores. Successful completion of IR procedures in the VLBW infant is possible, but complications still occur in these fragile infants. (orig.)

  3. Identifying the Learning Curve for Uterine Artery Embolisation in an Interventional Radiological Training Unit

    Energy Technology Data Exchange (ETDEWEB)

    Das, Raj, E-mail: rajdas@nhs.net, E-mail: raj.das@stgeorges.nhs.uk; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Wang, Haofan, E-mail: wwhhff123@gmail.com; Belli, Anna-Maria, E-mail: anna.belli@stgeorges.nhs.uk [St George’s Hospital, Department of Radiology (United Kingdom)

    2015-08-15

    AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to three groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.

  4. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery.

  5. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    International Nuclear Information System (INIS)

    2008-01-01

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery

  6. Evidence-based radiology: a new approach to evaluate the clinical practice of radiology; Evidenzbasierte Radiologie: Ein neuer Ansatz zur Bewertung von klinisch angewandter radiologischer Diagnostik und Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Puig, S. [Univ.Klinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria); Forschungsprogramm fuer Evidenzbasierte Medizinische Diagnostik, Inst. fuer Public Health, Paracelsus Medizinische Privatuniversitaet, Salzburg (Austria); Felder-Puig, R. [Ludwig-Boltzmann-Inst. fuer Health Technology Assessment, Vienna (Austria)

    2006-07-15

    Over the last several years, the concept and methodology of evidence-based medicine (EBM) have received significant attention in the scientific community. However, compared to therapeutic medical disciplines, EBM-based radiological publications are still underrepresented. This article summarizes the principles of EBM and discusses the possibilities of their application in radiology. The presented topics include the critical appraisal of studies on the basis on EBM principles, the explanation of EBM-relevant statistical outcome parameters (e.g., ''likelihood ratio'' for diagnostic and ''number needed to treat'' for interventional procedures), as well as the problems facing evidence-based radiology. Evidence-based evaluation of radiological procedures does not only address aspects of cost-effectiveness, but is also particularly helpful in identifying patient-specific usefulness. Therefore it should become an integral part of radiologist training. (orig.)

  7. Innovation is the permanent motivation to make continuous development of interventional radiology: comments about esophageal internal irradiation stent for the treatment of esophageal cancer

    International Nuclear Information System (INIS)

    Teng Gaojun

    2011-01-01

    Treatment of esophageal carcinoma is still a tough issue. Although metallic esophageal stent implantation is an important technique, as it can safety and quickly relieve the dysphagia caused by esophageal cancer, is has no effect on the malignant tumor itself. As a carrier of radioactive seeds, the novel esophageal stent plays functions of relieving dysphagia and conducting brachytherapy of the tumor, which creates a new therapy for esophageal carcinoma and expands the clinical significance of the stent implantation treatment. The history of interventional radiology indicates that it is the innovation that is the permanent motivation to make continuous development of interventional radiology. Innovations include new technology, new practical devices and new theories. Today, even if the interventional radiology has highly developed, innovation is till an 'unbreakable truth' for the development of interventional radiology and it makes the interventional radiology full of vitality. (author)

  8. Radiochromic film for dosimetric measurements in radiation shielding composites synthesized for applied in radiology procedures of high dose

    Energy Technology Data Exchange (ETDEWEB)

    Fontainha, C. C. P. [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Baptista N, A. T.; Faria, L. O., E-mail: crissia@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: Medical radiology offers great benefit to patients. However, although specifics procedures of high dose, as fluoroscopy, Interventional Radiology, Computed Tomography (CT) make up a small percent of the imaging procedures, they contribute to significantly increase dose to population. The patients may suffer tissue damage. The probability of deterministic effects incidence depends on the type of procedure performed, exposure time, and the amount of applied dose at the irradiated area. Calibrated radiochromic films can identify size and distribution of the radiated fields and measure intensities of doses. Radiochromic films are sensitive for doses ranging from 0.1 to 20 c Gy and they have the same response for X-rays effective energies ranging from 20 to 100 keV. New radiation attenuators materials have been widely investigated resulting in dose reduction entrance skin dose. In this work, Bi{sub 2}O{sub 3} and ZrO{sub 2}:8 % Y{sub 2}O{sub 3} composites were obtained by mixing them with P(VDF-Tr Fe) copolymers matrix from casting method and then characterized by Ftir. Dosimetric measurements were obtained with Xr-Q A2 Gafchromic radiochromic films. In this setup, one radiochromic film is directly exposed to the X-rays beam and another one measures the attenuated beam were exposed to an absorbed dose of 10 mGy of RQR5 beam quality (70 kV X-ray beam). Under the same conditions, irradiated Xr-Q A2 films were stored and scanned measurement in order to obtain a more reliable result. The attenuation factors, evaluated by Xr-Q A2 radiochromic films, indicate that both composites are good candidates for use as patient radiation shielding in high dose medical procedures. (Author)

  9. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    Science.gov (United States)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  10. StarClose Vascular Closure Device: Prospective Study on 222 Deployments in an Interventional Radiology Practice

    International Nuclear Information System (INIS)

    Imam, Atique; Carter, Ranjana M. S.; Phillips-Hughes, Jane; Boardman, Philip; Uberoi, Raman

    2007-01-01

    The StarClose device (Abbott Vascular Devices; Abbott Laboratories, Redwood City, CA) utilizes an externally placed Nitinol clip to achieve arterial closure following femoral artery puncture. The objectives of this study were to assess the efficacy and complications of the StarClose device in patients undergoing interventional radiological procedures. Preprocedural clotting status, pulse and blood pressure, severity of vessel calcification, sheath size, and time to deployment were recorded. Postdeployment complications immediately postprocedure, at 1 h, at 2 h, and at 1 week were recorded. A duplex scan was performed in the first 10 patients to assess any immediate vascular complications. Deployments were successful in 96% achieving immediate hemostasis. Mean deployment time was 48 s. There were no major complications. The StarClose device was found to have a high technical and clinical efficacy

  11. Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-04-01

    Full Text Available Background Increasing the x-ray film to focus distance (FFD, has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether increasing the FFD from 100 to 130 cm is equally effective for other common radiological procedures and performing a literature review of published studies to address the feasibility and probable limitations against implementing this optimization tool in clinical practice. Materials and Methods Radiographic examination of the pelvis (AP view, abdomen (AP view, skull (AP and lateral view, and spine (AP and lateral view, were taken of pediatric patients. The radiation dose and image quality of a radiological procedure is measured in FFD of 100 cm (reference FFD and 130 cm (increased FFD. The thermo-luminescent dosimeters (TLD were used for radiation dose measurements and visual grading analysis (VGA for image quality assessments. Results: Statistically significant reduction in the ESD ranged from 21.91% for the lateral skull projection to 35.24% for the lateral spine projection was obtained, when the FFD was increased from 100 to 130 cm (P0.05. Conclusion Increasing the FFD from 100 to 130 cm has significantly reduced radiation exposure without affecting on image quality. Our findings are commensurate with the literatures and emphasized that radiographers should learn to use of an updated reference FFD of 130 cm in clinical practice.

  12. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  13. The mandate and work of ICRP Committee 3 on radiological protection in medicine.

    Science.gov (United States)

    Miller, D L; Martin, C J; Rehani, M M

    2018-01-01

    The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.

  14. Nanotechnology and its relationship to interventional radiology. Part II: Drug Delivery, Thermotherapy, and Vascular Intervention.

    LENUS (Irish Health Repository)

    Power, Sarah

    2012-02-01

    Nanotechnology can be defined as the design, creation, and manipulation of structures on the nanometer scale. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part 2 of the article concentrates on drug delivery, thermotherapy, and vascular intervention. In oncology, advances in drug delivery allow for improved efficacy, decreased toxicity, and greater potential for targeted therapy. Magnetic nanoparticles show potential for use in thermotherapy treatments of various tumours, and the effectiveness of radiofrequency ablation can be enhanced with nanoparticle chemotherapy agents. In vascular intervention, much work is focused on prevention of restenosis through developments in stent technology and systems for localised drug delivery to vessel walls. Further areas of interest include applications for thrombolysis and haemostasis.

  15. Nanotechnology and its Relationship to Interventional Radiology. Part II: Drug Delivery, Thermotherapy, and Vascular Intervention.

    LENUS (Irish Health Repository)

    Power, Sarah

    2010-09-16

    Nanotechnology can be defined as the design, creation, and manipulation of structures on the nanometer scale. This two-part review is intended to acquaint the interventionalist with the field of nanotechnology, and provide an overview of potential applications, while highlighting advances relevant to interventional radiology. Part 2 of the article concentrates on drug delivery, thermotherapy, and vascular intervention. In oncology, advances in drug delivery allow for improved efficacy, decreased toxicity, and greater potential for targeted therapy. Magnetic nanoparticles show potential for use in thermotherapy treatments of various tumours, and the effectiveness of radiofrequency ablation can be enhanced with nanoparticle chemotherapy agents. In vascular intervention, much work is focused on prevention of restenosis through developments in stent technology and systems for localised drug delivery to vessel walls. Further areas of interest include applications for thrombolysis and haemostasis.

  16. Conclusions and recommendations of the European ORAMED project for practical interventional radiology and nuclear medicine

    International Nuclear Information System (INIS)

    Nikodemova, Denisa; Fueloep, Marko; Cabanekova, Helena

    2012-01-01

    The results of the recently published doses obtained by medical staff working in pulsed radiation fields, and performing interventional radiology (IR) or interventional cardiology (IC) procedures, as well as applications of radionuclides in nuclear medicine (NM), have shown significantly high levels of exposure, mainly to the hands and other parts of their bodies uncovered by protective equipment. The coordinated project ORAMED (Optimization of Radiation Protection of Medical Staff) was set-up by participation of 12 European countries and 34 IR/IC and NM departments, with the 5 main tasks: (i) optimization of radiation protection in IR and IC,with the aim to standardize a unified method of extremities and eye lens doses estimation, for 3 cardiac and 5 interventional diagnostic and therapeutic examinations; (ii) verification of the possibilities to use active personal dosemeters for typical pulsed radiation fields used in IR and IC; (iii) contribution to the extremities and eye lens dose reduction in nuclear medicine; (iv) development and application of a suitable eye lens dosemeter; and (v) elaboration of training materials and guidelines for radiation protection issues at IR, IC and NM workplaces. The present study presents some important results and recommendations for dose reduction and avoidance of some typical failures during work near ionizing radiation sources. (P.A.)

  17. Dosimetric studies of the lens of the eye using a new dosimeter - polls in two departments of Interventional Radiology of the autonomous city of Buenos Aires

    International Nuclear Information System (INIS)

    Pirchio, R.; Sánchez, H.; Domazet, W

    2013-01-01

    During interventional radiology (IR) and cardiology (IC) procedures, medical staff can receive high doses to their eye lenses. The Retrospective Evaluation of Lens Injuries and Dose (RELID) study organized in Argentina in 2010 found incipient opacity in 50% of IC physicians and 41% of IC technicians/nurses. These results, added to the recommendations of the International Commission on Radiological Protection (ICRP), which lowered their former occupational equivalent dose limit for the lens, led us to assess the eye lens dose, Hp(3), during interventional procedures. To this end, a new dosemeter was designed and calibrated at the National Atomic Energy Commission (CNEA) of Argentina to evaluate Hp(3). Personal dose equivalent (Hp(10)), and Hp(3) were assessed for 3 months in two IC and IR departments of Buenos Aires City using thermoluminescent dosimeters (TLD) and electronic personal dosimeter (EPD). An Rando Alderson phantom was used to simulate monthly exposures of five occupational staff members. Hp(3) and Hp(10) were obtained monthly for 14 occupational staff members exposed to 121 IR and IC procedures. We concluded that the annual effective dose and Hp(3) were lower than 0.3 and 10 mSv, respectively. An occupational annual dose constraint of 0.3 mSv was calculated. Average cumulative Hp(3) for working life of 40 years should be lower than 400 and 200 mSv for physicians and technicians/scrub nurse, respectively. Also we concluded that a calibrated EPD worn on a pocket in the lead apron and a TLD dosemeter worn on the collar thyroid (both at the maximal radiation side) could be used as guidance to the lens dose. Finally, To reduce doses of medical staff, actions should be promoted to maximize radiation protection in interventional procedures with appropriate training, using personal dosimetry and protection instruments as lead glasses, ceiling-suspended shields and others. (author)

  18. Extracorporeal shock wave lithotripsy: Involvement and impact on radiology at a kidney stone center

    International Nuclear Information System (INIS)

    Cochran, S.T.; Barbaric, Z.L.; Mindell, H.; Chaussy, C.D.; Fuchs, G.J.

    1986-01-01

    Of 1,222 extracorporeal shock wave lithotripsy (ECSW) procedures performed on 925 patients (600 males, 325 females), 85% were unilateral and 35% were bilateral treatments. Treated were 446 calyceal, 345 pelvic, 172 uretral, and 108 staghorn calculi. The impact of this new technology to the radiology department was studied. An average of 6.3 KUB studies and 1.2 renal US studies were performed per treatment session. Six percent of patients required post-ESWL excretory urography of CT; 10% required percutaneous nephrostomy. Patients with treated staghorn calculi required the most radiologic procedures (34% performed for partial staghorn calculi, 56% for complete staghorn calculi). By comparison, 3%, 8%, and 11% of radiologic procedures were performed for calyceal, pelvic, and ureteral stones, respectively. The impact of ESWL on the radiology department can be substantial. When staghorn calculi are treated by ESWL, a radiologist skilled in interventional techniques is essential

  19. Assessment of exposure to scattered radiation in interventional procedures using special protective bismuth; Evaluacion de la exposicion a radiacion dispersa en procedimientos intervencionistas usando protectores especiales de bismuto

    Energy Technology Data Exchange (ETDEWEB)

    Soto Bua, M.; Medina Jimenez, E.; Vazquez Vazquez, R.; Santamaria Vazquez, F.; Otero Martinez, C.; Lobato Busto, R.; Luna Vega, V.; Mosquera Suero, J.; Sanchez Garcia, M.; Pombar Camean, M.

    2011-07-01

    There are currently marketed specific producta aimed at reducing personnel exposure to radiation scattered in cardiac catheterization procedures, interventional radiology or electrophysiology. Our service has been proposed to study the attenuation characteristics of the product Drape Armour manufactured by the company Microtek. Is a flexible devices constructed from an alloy of bismuth and sterility characteristics and infection control and fluid makes them particularly suitable for incorporating into the operative field of the patient. To study their behavior, there have been staff dose measurements representative of the moaL common situations of exposure to scattered radiation in a typical procedure of intervention.

  20. Calculation of entrance exposed area from recorded images in cardiac diagnostic and interventional procedures

    International Nuclear Information System (INIS)

    Bibbo, G.; Balman, D.

    2000-01-01

    With increasing number of interventional radiological procedures performed on patients of all ages, it is important to determine the skin entrance dose of patients to limit the side effects of radiation. In most cases the skin dose is measured using thermoluminescent detectors (TLD). However, these detectors need to be placed in the radiation field on the skin of the patient, which may interfere with the procedure. Also, not all radiological practices are equipped with TLD readers which are expensive or have staff with the appropriate knowledge and expertise to be able to make use of TLD. The alternative to TLD is to use the dose area product (DAP) measured with a diamentor fitted to the angiography x-ray equipment. The difficulties in using DAP to calculate skin dose is that the irradiated area of the skin is not known. The area could change in size and location during the procedure as the radiologist/medical specialist varies the collimation and region of interest. For angiography equipment the distance between the anode and image intensifier is variable, as is the height of the examination table. The only point of reference is the isocentre. With recorded images it is possible to determine the irradiated area of the patient at the isocentre plane using the stenosis algorithm. The recorded image is calibrated such that it corresponds to the physical size in the plane of the isocentre. For non-recorded images, it may be necessary to assume that collimation has not changed and that the irradiated area is the same as that shown on the recorded images. The Women's and Children's Hospital has a Toshiba DFP2000 Biplane Digital Imaging system used for all cardiac and general angiography and interventional procedures. With this system the exposure factors (kVp, mA, field sizes) are recorded with the images. The source to image distance (SID), magnification factor (calibration factor of the recorded images) and angle of rotation are displayed on the Display Panel of the

  1. The role of interventional radiology in management of patients with end-stage renal disease

    International Nuclear Information System (INIS)

    Surlan, M.; Popovic, P.

    2003-01-01

    The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success rates are over 90% for dilatation. One-year primary patency rate in forearm fistula is 51%, versus graft 40%. Stents are placed only in selected cases; routinely in central vein after dilatation, in ruptured vein and elastic recoil. Thrombosed fistula and grafts can be declotted by purely mechanical methods or in combination with a lytic drug. The success rate of the technique is 89-90%. Primary patency rate is 8-26% per year and secondary 75% per year. The most frequently radiologically evaluated and treated complications in renal transplantation are perirenal and renal fluid collection and abnormalities of the vasculature and collecting system. US is often the method of choice for the diagnostic evaluation and management of the percutaneous therapeutic procedures in early and late transplantation complications. Computed tomography and magnetic resonance are valuable alternatives when US is inconclusive. Renal and perirenal fluid collection are usually treated successfully with

  2. Reimbursement of radiologically guided vascular interventions within the DRG-System: What wil change?; Verguetung radiologischer Gefaessinterventionen im DRG-System: Was wird sich aendern?

    Energy Technology Data Exchange (ETDEWEB)

    Strotzer, M. [Krankenhaus Hohe Warte, Bayreuth (Germany). Abt. fuer Radiologie; Feuerbach, S. [Klinikum der Univ. Regensburg (Germany). Inst. fuer Diagnostische Radiologie; Voelk, M. [Bundeswehrkrankenhaus Ulm (Germany). Abt. Radiologie

    2004-09-01

    Purpose: To evaluate reimbursement within the DRG-system ('diagnosis-related groups') compared with traditional reimbursement for interventional therapy of hospitalized patients. Materials and Methods: Reimbursement calculation was prospectively analyzed in two respects for 30 consecutive patients who underwent percutaneous transluminal angioplasty (PTA) of the lower extremity arteries: (1) based on the DRG-system; (2) based on the traditional system. Additional evaluation was performed for five further, typical vascular procedures on the basis of real documentation and calculation data (stenting of the carotid artery, fibrinolytic therapy of basilar artery occlusion, stenting of renal artery stenosis, angioplasty of hemodialysis-shunt stenosis and aspiration thrombectomy of an infrapopliteal arterial occlusion). Results: In our hospital, the introduction of the DRG system would reduce reimbursement by approximately 1100 Euro per PTA patient. However, the other vascular radiological procedures can be expected to increase the payments by up to 4500 Euro. Conclusion: To minimize imminent reduction of reimbursement for patients with peripheral PTA, complete documentation and economical patient management is mandatory. Payment may increase significantly for patients with the other reported vascular interventional procedures. (orig.)

  3. Factors Influencing Choice of Radiology and Relationship to Resident Job Satisfaction.

    Science.gov (United States)

    Matalon, Shanna A; Guenette, Jeffrey P; Smith, Stacy E; Uyeda, Jennifer W; Chua, Alicia S; Gaviola, Glenn C; Durfee, Sara M

    2018-03-20

    Identify when current radiology residents initially became interested in radiology, which factors influenced their decision to pursue a career in radiology, and which factors correlate with job satisfaction. An online survey was distributed to United States radiology residents between December 7, 2016 and March 31, 2017. Respondents identified the most appealing aspects of radiology during medical school, identified experiences most influential in choosing radiology, and scored job satisfaction on visual analog scales. Relative importance was compared with descriptive statistics. Satisfaction scores were compared across factors with analysis of variance and post-hoc Tukey tests. 488 radiology residents responded (age 30.8 ± 3.2 years; 358 male, 129 female, 1 unknown; 144 PGY2, 123 PGY3, 103 PGY4, 118 PGY5). The most influential aspects in choosing radiology were the intellectual (n=187, 38%), imaging (n=100, 20%), and procedural (n=96, 20%) components and potential lifestyle (n=69, 14%). Radiology clerkship reading room shadowing (n=143, 29%), radiologist mentor (n=98, 20%), non-radiology clerkship imaging exposure (n=77, 16%), and radiology clerkship interventions exposure (n=75, 15%) were most influential. Choosing radiology because of potential lifestyle correlated with less job satisfaction than choosing radiology for intellectual (p=0.0004) and imaging (p=0.0003) components. Recruitment of medical students into radiology may be most effective when radiology clerkships emphasize the intellectual and imaging components of radiology through reading room shadowing and exposure to interventions. Choosing radiology for lifestyle correlates with less job satisfaction, at least during residency. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Is the timing of radiological intervention and treatment day associated with economic outcomes in DRG-financed health care systems: a case study.

    Science.gov (United States)

    Napierala, Christoph; Boes, Stefan

    2017-02-28

    In 2012, Switzerland has introduced a diagnosis related group (DRG) system for hospital financing to increase the efficiency and transparency of hospital services and to reduce costs. However, little is known about the efficiency of specific processes within hospitals. The objective of this study is to describe the relationship between timing of radiological interventions, in particular scan and treatment day, and the length of stay (LOS) compliance in a hospital. This is a cross-sectional observational study based on administrative records of all DRG cases in a Swiss university hospital in 2013, enriched by data from the radiology information system and accounting details. The data are analysed using descriptive statistics and regression methods. Radiology and related treatment on a weekend is associated with a higher LOS compliance of approximately 22.12% (pDRG and attempts to explain how this is linked to standardised operating procedures. Our results have implications regarding potential cost savings in hospital care through alignment of care processes, infrastructure planning and guidance of patient flows.

  5. Life-threatening bleeding and radiologic intervention after aesthetic surgeries with minimal invasive approaches: report of two cases.

    Science.gov (United States)

    Kim, Youn-Hwan; Kim, Jong-Do; Visconti, Giuseppe; Kim, Jeong-Tae

    2010-10-01

    In this article, the authors report two cases of life-threatening bleeding after cosmetic surgeries that have been successfully treated with radiologic intervention. A 25-year-old female and a 35-year-old female presented at their institutions because of postoperative bleeding after intraoral mandibular angle ostectomy and endoscopic-guided trans-axillary breast augmentation, respectively. A ruptured traumatic pseudo-aneurysm of the right superficial temporal artery was diagnosed in the first case and a haematoma posterior to the right pectoralis major, due to active bleeding from a perforator of internal mammary artery, in the second case. Attempts were made to stop the haemorrhage using standard methods, but failed. Therefore, superselective microcatheter angioembolisation has been successfully performed in both the cases. At 22-month follow-up for the first case and at 12-month follow-up for the second case, the patients are asymptomatic and the cosmetic outcomes are being preserved. With radiologic intervention, the authors gained satisfactory results in the above-mentioned situations. Using this, with only local anaesthesia and the absence of incisions, a precise approach with immediate treatment to the haemorrhaging site is possible. This can be an excellent solution for arterial bleeding that is difficult to access anatomically after aesthetic surgeries, and in selected cases. Furthermore, this procedure is less disfiguring and preserves the aesthetic surgery outcomes. Copyright 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. The Future of Radiology

    Directory of Open Access Journals (Sweden)

    Alexander R. Margulis

    2011-07-01

    Full Text Available It has been my good fortune to live and practice radiology during a long period of momentous change – to see the transformation of the discipline from a supportive service into a mainstream, essential branch of clinical medicine. I remember wearing red goggles to adapt my vision before performing fluoroscopy; observing the horrible, now thankfully obsolete, practice of ventriculography, which was considered advanced neuroradiology; and performing other, now rarely prescribed procedures, such as double-contrast barium enemas and intravenous pyelography. Witnessing the beginnings of interventional radiology, I suggested its name in an editorial. I also had the good fortune to see the introduction of computed tomography (CT and a technology first known as nuclear magnetic resonance imaging. Together with fellow members of a committee of the American College of Radiology and editors of prestigious radiological journals, I took part in changing the name of the latter modality to MRI, freeing it from threatening implications. Looking back on these experiences, one lesson stands out above all: Innovation and transformation never cease. Looking forward, it is clear that radiology, along with the rest of medicine, is now undergoing further momentous changes that will affect the future of all those already practicing as well as those yet to start their careers.

  7. Assessment of radiation protection of patients and staff in interventional procedures in four Algerian hospitals

    International Nuclear Information System (INIS)

    Khelassi-Toutaoui, N.; Toutaoui, A.; Merad, A.; Sakhri-Brahimi, Z.; Baggoura, B.; Mansouri, B.

    2016-01-01

    This study was aimed to assess patient dosimetry in interventional cardiology (IC) and radiology (IR) and radiation safety of the medical operating staff. For this purpose, four major Algerian hospitals were investigated. The data collected cover radiation protection tools assigned to the operating staff and measured radiation doses to some selected patient populations. The analysis revealed that lead aprons are systematically worn by the staff but not lead eye glasses, and only a single personal monitoring badge is assigned to the operating staff. Measured doses to patients exhibited large variations in the maximum skin dose (MSD) and in the dose area product (DAP). The mean MSD registered values are as follows: 0.20, 0.14 and 1.28 Gy in endoscopic retrograde cholangio-pancreatography (ERCP), coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures, respectively. In PTCA, doses to 3 out of 22 patients (13.6 %) had even reached the threshold value of 2 Gy. The mean DAP recorded values are as follows: 21.6, 60.1 and 126 Gy cm 2 in ERCP, CA and PTCA procedures, respectively. Mean fluoroscopic times are 2.5, 5 and 15 min in ERCP, CA and PTCA procedures, respectively. The correlation between DAP and MSD is fair in CA (r = 0.62) and poor in PTCA (r = 0.28). Fluoroscopic time was moderately correlated with DAP in CA (r = 0.55) and PTCA (r = 0.61) procedures. Local diagnostic reference levels (DRLs) in CA and PTCA procedures have been proposed. In conclusion, this study stresses the need for a continuous patient dose monitoring in interventional procedures with a special emphasis in IC procedures. Common strategies must be undertaken to substantially reduce radiation doses to both patients and medical staff. (authors)

  8. Implementation of Ray Safe i2 System for staff dose measuring in interventional radiology

    International Nuclear Information System (INIS)

    Gershan, Vesna; Atsovska, Violeta

    2013-01-01

    Interventional radiology procedures usually delivered the highest radiation dose to the patients as well as to medical personal. Beside another factors like patient size, fluoroscopy time, machine calibration etc., a good clinical practice has strong effects to staff and patient’s radiation dose. Materials and methods: In August 2012, a Ray Safe i2 system was installed in a private hospital in Skopje. The main purpose of this dosimetry system is to provide real time indication for the current exposure level of the medical personal. Knowing that, the staff has prerequisites to adjust their behavior to minimize unnecessary exposure like changing distance from exposed volume, C-ram angulations, field of view etc. and on this way to develop a good clinical practice. The Ray Safe i2 system is consisted by ten digital dosimeters, two dock stations, real time display, dose viewer and dose manager software. During interventional procedures, each involved staff wears dosimeter which measures and records X-Ray exposure every second and transfer the data wirelessly to the real time display. Color indication bars (green, yellow, red) represents the intensity of the currently received exposure, whereas green zone indicates < 0.2 mSv/h, yellow zone from 0.2 to 2 mSv/h and red zone indications from 2 to 20 mSv/h. Additionally, accumulated dose per individual is displayed next to the color indication bars. By using the software, information about personal dose history, such as annual dose, dose per particular session, hour, day or week, can be viewed and analyzed. Results: In this work it was found that staff accumulated doses were constantly increased over time, but reported number of procedures does not correspond to this tendency. Our assumption is that there is a misleading between reported number and actual performed procedures. Doctor1 received 55 times more dose than Doctor2 and Nurse1 received 11 to 3 times more dose than another Nurses. It was found a correlation of R2

  9. Pediatric radiology

    International Nuclear Information System (INIS)

    Kirkpatrick, J.A. Jr.

    1985-01-01

    Computed tomography has made possible the excellent and basic work having to do with the characteristics of the trachea, its caliber, shape, and length in children. Another group of articles has to do with interventional pediatric radiology. This year there were a number of articles of which only a sample is included, dealing with therapeutic procedures involving drainage of abscesses, angioplasty, nephrostomy, therapeutic embolization, and the removal of esophageal foreign bodies. Obviously, there is no reason to think that techniques developed for the adult may not be applicable to the infant or child; also, there is no reason to believe that processes peculiar to the child should not be amenable to intervention, for instance, use of embolization of hepatic hemangioma and transluminal balloon valvuloplasty for pulmonary valvular stenosis. Among the reports and reviews, the author would add that sonography remains a basic imaging technique in pediatric radiology and each year its application broadens. For example, there is an excellent article having to do with sonography of the neonatal and infant hip and evaluation of the inferior vena cava and the gallbladder. Nuclear medicine continues to play a significant role in diagnosis, which is featured in two articles concerned with problems of the hip

  10. Standards of diagnostic radiological safety

    International Nuclear Information System (INIS)

    Yacovenco, A.; Ferreira, R.

    1996-01-01

    Brazil as well as many other countries are characterized for the access differentiated from the society to the products of the development. The lacking in specifications tolerance and mainly requirements of security and they of protection have induced to the inadequate utilization of the procedures technical and products in the area of radiology. We in this context are proposing a new mode of relationships between the diverse levels of intervention and responsibility

  11. Procedures minimally invasive image-guided

    International Nuclear Information System (INIS)

    Mora Guevara, Alejandro

    2011-01-01

    A literature review focused on minimally invasive procedures, has been performed at the Department of Radiology at the Hospital Calderon Guardia. A multidisciplinary team has been raised for decision making. The materials, possible complications and the available imaging technique such as ultrasound, computed tomography, magnetic resonance imaging, have been determined according to the procedure to be performed. The revision has supported medical interventions didactically enjoying the best materials, resources and conditions for a successful implementation of procedures and results [es

  12. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    International Nuclear Information System (INIS)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-01-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  13. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games.

    Science.gov (United States)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-10-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9% were magnetic resonance imaging (MRI) scans, 22% were diagnostic ultrasound (US) examinations, 33.1% were radiographs, 4.3% were computed tomography (CT) scans and 2.7% were imaging-guided interventional procedures. 88% of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events.

  14. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    Energy Technology Data Exchange (ETDEWEB)

    Bethapudi, Sarath [County Durham Darlington Foundation NHS Trust, Durham (United Kingdom); Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Ritchie, David [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Greater Glasgow and Clyde Hospitals NHS Trust, Western Infirmary, Glasgow (United Kingdom); Bongale, Santosh [Glasgow 2014 Commonwealth Games, Immediate Care Department, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Royal Alexandra Hospital, Paisley (United Kingdom); Gordon, Jonny [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Glasgow (United Kingdom); MacLean, John [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); National Stadium Sports Medicine Centre, Glasgow (United Kingdom); Mendl, Liz [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom)

    2015-10-15

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  15. A cross-site vascular radiology on-call service: the Manchester experience

    International Nuclear Information System (INIS)

    Ashleigh, R.J.; Butterfield, J.S.; Asquith, J.; Chalmers, N.; Murphy, G.

    2005-01-01

    AIM: A cross-site vascular radiology on-call service was established 5 years ago to cover two vascular centres in Manchester. We aimed to review the service. MATERIALS AND METHODS: A prospective audit of out-of hours referrals and procedures over a three month period (March-May 2003) was undertaken. RESULTS: There were 52 incidents in 49 patients (mean 4 calls per week). Nine involved telephone advice only, the remainder (82%) required a procedure. Angiography was performed on 88% of patients and therapeutic radiological intervention on 50%. 71% of calls occurred at a weekend. 50% of the calls were from vascular surgery and 50% from other sources. The consultant vascular radiologist was present for 93% of procedures. CONCLUSIONS: The workload suggests that a vascular radiology on call service is justified in Manchester. There have been no major problems with its implementation and operation. This is a consultant led service, with very few cases being devolved to a specialist registrar (SpR)

  16. Interventional radiology and endovascular surgery in the treatment of ectopic pregnancies

    Energy Technology Data Exchange (ETDEWEB)

    Fornazari, Vinicius Adami Vayego; Szejnfeld, Denis; Elito, Julio Júnior; Goldman, Suzan Menasce [Universidade Federal de São Paulo, São Paulo, SP (Brazil)

    2015-07-01

    The advent of interventional radiology enabled remarkable advances in diagnosis and treatment of several situations in obstetrics and gynecology. In the field of obstetrics, these advances include temporary occlusion of the iliac arteries to the management of placenta accreta and/or prior, arteriovenous fistulas after embolization of uterine curettage and management of ectopic uterine and extra-uterine pregnancies. The non-tubal ectopic pregnancy, either cervical, abdominal, ovarian or in a cesarean scar, often represents major therapeutic challenge, especially when exists a desire to maintain fertility. Despite the systemic methotrexate therapy and surgical resection of the ectopic gestational sac be the most used therapeutic options, the interventionist approach of non-tubal ectopic pregnancies, direct injection of methotrexate in the gestational sac and intra-arterial chemoembolization of uterine arteries constitute in the currently literature viable, safe, effective modalities with low morbidity, shorter hospital stay, and rapid clinical recovery. Because of little variety of materials used, and the increase in training of specialists in the area, the radiological intervention as a treatment option in ectopic pregnancies is financially viable and present considerable accessibility in the world and at most of Brazilian medical centers.

  17. Reference Dose Rates for Fluoroscopy Guided Interventions

    International Nuclear Information System (INIS)

    Geleijns, J.; Broerse, J.J.; Hummel, W.A.; Schalij, M.J.; Schultze Kool, L.J.; Teeuwisse, W.; Zoetelief, J.

    1998-01-01

    The wide diversity of fluoroscopy guided interventions which have become available in recent years has improved patient care. They are being performed in increasing numbers, particularly at departments of cardiology and radiology. Some procedures are very complex and require extended fluoroscopy times, i.e. longer than 30 min, and radiation exposure of patient and medical staff is in some cases rather high. The occurrence of radiation-induced skin injuries on patients has shown that radiation protection for fluoroscopy guided interventions should not only be focused on stochastic effects, i.e. tumour induction and hereditary risks, but also on potential deterministic effects. Reference dose levels are introduced by the Council of the European Communities as an instrument to achieve optimisation of radiation protection in radiology. Reference levels in conventional diagnostic radiology are usually expressed as entrance skin dose or dose-area product. It is not possible to define a standard procedure for complex interventions due to the large inter-patient variations with regard to the complexity of specific interventional procedures. Consequently, it is not realistic to establish a reference skin dose or dose-area product for complex fluoroscopy guided interventions. As an alternative, reference values for fluoroscopy guided interventions can be expressed as the entrance dose rates on a homogeneous phantom and on the image intensifier. A protocol has been developed and applied during a nationwide survey of fluoroscopic dose rate during catheter ablations. From this survey reference entrance dose rates of respectively 30 mGy.min -1 on a polymethylmethacrylate (PMMA) phantom with a thickness of 21 cm, and of 0.8 μGy.s -1 on the image intensifier have been derived. (author)

  18. Patient exposure evaluation in Romanian radiological departments

    International Nuclear Information System (INIS)

    Girjoaba, O.; Cucu, A.

    2012-01-01

    Purpose: A nation-wide evaluation of ionizing radiation exposure of the Romanian population due to the radiological examinations is performed in accordance with European Directive 97/43 EURATOM implemented in national regulations. Method: The study is applied to the collected data from radiological departments from Romanian hospitals during 2010. The radiological examinations were grouped in three categories: conventional diagnostic radiology, interventional radiology and computed tomography. The annual collective dose was determined from the reported data about the mean effective doses and the frequency for each type of radiological examination, in conformity with the national regulations. Regarding the frequency aspects, the results include the age and gender distributions. Major results: More then 6 million radiological examinations were performed in 2010, Romania having a population about of 20.3 million inhabitants. The collective effective dose for 2010 resulted from the study is 152 mSv per 1000 inhabitants. Conclusions: Medical practitioners must select the best medical imaging investigation for each clinical case taking into account the importance of keeping the patient dose as low as possible. Medical physicists should be strongly involved in the establishing of the dosimetry procedures. (author)

  19. Interventional radiological therapy of benign low back pain syndromes

    International Nuclear Information System (INIS)

    Huegli, R.W.; Jacob, A.L.; Steinbrich, W.

    2007-01-01

    Spinal affections belong to the most widespread sources of back pain. Beside medical history and clinical examination, the radiological investigation plays an important rote in the clinical workup especially with the modern Cross sectional imaging methods such as computed and magnetic resonance tomography. After exclusion of a malignant disease usually a conservative therapeutic approach is the first line treatment option. If the conservative treatment approach falls a minimalinvasive image guided diagnostic or therapeutic infiltration may be considered. Thereby the interventional radiologist should be a member of the team which decides the clinical strategy. This article describes epidemiology and pathophysiology, common pre-interventional diagnostic strategies, drugs, indications, possible complications and the impact of diagnostic and therapeutic minimally invasive image guided techniques in low back pain. In this context facet joint blockade, periradicular and peridural therapy as well as sacroiliac joint blockades are discussed

  20. Fast skin dose estimation system for interventional radiology.

    Science.gov (United States)

    Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru

    2018-03-01

    To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.

  1. The Effect of the Extinction Procedure in Function-Based Intervention

    Science.gov (United States)

    Janney, Donna M.; Umbreit, John; Ferro, Jolenea B.; Liaupsin, Carl J.; Lane, Kathleen L.

    2013-01-01

    In this study, we examined the contribution of the extinction procedure in function-based interventions implemented in the general education classrooms of three at-risk elementary-aged students. Function-based interventions included antecedent adjustments, reinforcement procedures, and function-matched extinction procedures. Using a combined ABC…

  2. Dosimetry in medical specialist in procedures of interventionist radiology

    International Nuclear Information System (INIS)

    Gaona, E.; Vazquez V, J. A.; Rivera M, T.; Izeta G, A. C.; Azorin V, J. C.; Arreola, M.

    2014-08-01

    In this work are presented the experimental results of determining the dose in different body parts, measured by thermoluminescent dosimeters, to medical specialists of implantation procedures of definitive cardiac pacemaker. The medical personnel in ten intervention procedures were controlled according to the procedure type, pathological indication, fluoroscopy time and machine generating estimates of the patient doses. The doses to the extremities of the cardiologist were measured by means of thermoluminescent dosimeters (TLD). The domains of first level in the hand are in the index finger of the left and the right hand. The medium doses of the skin in the eyes, a report of the dose received during each type of intervention procedure in the glandular thyroid and fingers of the cardiologists is made. The results represent the integrated dose to the cardiologist, received during the implantation procedures of definitive cardiac pacemaker in the same patient. By a half time of detection of 70 minutes for patient, the half dose of the skin, received for the right and left hand, ascended to 1,4 mSv, under the glove. In conclusion, the dose average for the dosimeters of the thyroid gland and forehead was varied from 0,41 up to 1,14 mSv for study. The exposure to the X-rays is a topic to consider, more important every time on the development of systematic procedures little invasive, including the angiography, catheter, worker and patient. (Author)

  3. Interventional radiologic placement of tunneled central venous catheters : results and complications in 557 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Kyo; Do, Young Soo; Paik, Chul H. [Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)] (and others)

    1999-05-01

    To evaluate prospectively the results of interventional radiologic placement of tunneled central venous catheters, and subsequent complications. Between April 1997 and April 1998, a total of 557 tunneled central venous catheters were percutaneously placed in 517 consecutive patients in an interventional radiology suite. The indications were chemotherapy in 533 cases, total parenteral nutrition in 23 and transfusion in one. Complications were evaluated prospectively by means of a chart review, chest radiography, central vein angiography and blood/catheter culture. The technical success rate for tunneled central venous catheter placement was 100% (557/557 cases). The duration of catheter placement ranged from 4 to 356 (mean, 112{+-}4.6) days; Hickman catheters were removed in 252 cases during follow-up. Early complications included 3 cases of pneumothorax(0.5%), 4 cases of local bleeding/hematoma(0.7%), 2 cases of primary malposition(0.4%), and 1 case of catheter leakage(0.2%). Late complications included 42 cases of catheter-related infection(7.5%), 40 cases of venous thrombosis (7.2%), 18 cases of migration (3.2%), 5 cases of catheter / pericatheter of occlusion(0.8%), and 1 case of pseudoaneurysm(0.2%). The infection rate and thrombosis rate per 1000 days were 1.57 and 1.50, respectively. The technical success rate of interventional radiologic placement of tunneled central venous catheters was high. In comparison to conventional surgical placement, it is a more reliable method and leads to fewer complications.

  4. Cost and Morbidity Analysis of Chest Port Insertion: Interventional Radiology Suite Versus Operating Room.

    Science.gov (United States)

    LaRoy, Jennifer R; White, Sarah B; Jayakrishnan, Thejus; Dybul, Stephanie; Ungerer, Dirk; Turaga, Kiran; Patel, Parag J

    2015-06-01

    To compare complications and cost, from a hospital perspective, of chest port insertions performed in an interventional radiology (IR) suite versus in surgery in an operating room (OR). This study was approved by an institutional review board and is HIPAA compliant. Medical records were retrospectively searched on consecutive chest port placement procedures, in the IR suite and the OR, between October 22, 2010 and February 26, 2013, to determine patients' demographic information and chest port-related complications and/or infections. A total of 478 charts were reviewed (age range: 21-85 years; 309 women, 169 men). Univariate and bivariate analyses were performed to identify risk factors associated with an increased complication rate. Cost data on 149 consecutive Medicare outpatients (100 treated in the IR suite; 49 treated in the OR) who had isolated chest port insertions between March 2012 and February 2013 were obtained for both the operative services and pharmacy. Nonparametric tests for heterogeneity were performed using the Kruskal-Wallis method. Early complications occurred in 9.2% (22 of 239) of the IR patients versus 13.4% (32 of 239) of the OR patients. Of the 478 implanted chest ports, 9 placed in IR and 18 placed in surgery required early removal. Infections from the ports placed in IR versus the OR were 0.25 versus 0.18 infections per 1000 catheters, respectively. Overall mean costs for chest port insertion were significantly higher in the OR, for both room and pharmacy costs (P chest ports in an OR setting was almost twice that of placement in the IR suite. Hospital costs to place a chest port were significantly lower in the IR suite than in the OR, whereas radiology and surgery patients did not show a significantly different rate of complications and/or infections. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  6. Multimodality imaging to guide cardiac interventional procedures

    NARCIS (Netherlands)

    Tops, Laurens Franciscus

    2010-01-01

    In recent years, a number of new cardiac interventional procedures have been introduced. Catheter ablation procedures for atrial fibrillation (AF) have been refined and are now considered a good treatment option in patients with drug-refractory AF. In cardiac pacing, cardiac resynchronization

  7. Technical support and preparations for the response to radiological emergencies

    International Nuclear Information System (INIS)

    Cardenas H, J.; Ramos V, E.O.; Fernandez G, I.M.; Capote F, E.; Zerquera J, T.; Garcia L, O.; Lopez B, G.; Molina P, D.; Lamdrid B, A.I.; Benitez N, J.C.; Salgado M, M.; Lopez F, Y.; Jerez V, P.

    2006-01-01

    The work picks up the efforts directed to elevate the technical capacity of the answer in front of the radiological emergencies. Expressing them by means of the actions carried out as for teaching, research and development and intervention before accidental radiological events. The same one reflects the leading role of the participant institutions in those marks of the answer system to radiological emergencies that for its technical level it satisfies the national and international demands in the matter. In execution of the mentioned goals research projects guided to endow to the national system of methodologies and procedures for the administration of radiological emergencies have been executed that favor the improvement of its technical and organizational capacities. As well as the postulates of the National Plan of Measures for Case of Catastrophes in the corresponding to radiological accidents. (Author)

  8. The transjugular intrahepatic portosystemic stentshunt (TIPSS): A new nonoperative, transjugular percutaneous procedure. [Radiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G M; Noeldge, G; Siegerstetter, V; Franke, M; Wenz, W; Palmaz, J C; Roessle, M

    1989-08-01

    In a 49-year-old male patient suffering from severe symptoms of end-stage portal hypertension and Child's stage C metabolic status, an intrahepatic stent-assisted portosystemic shunt was established for the first time exclusively by means of interventional radiology. Via transjugular access, a modified Brockenbrough needle was used to puncture the right branch of the portal vein via the right liver vein. As a target, a Dormia-basket was used that had previously been exposed in the right main portal branch. After successful puncture and balloon dilation of the artificial tract, two Palmaz stents were implanted to keep the tract permanently open. The portosystemic pressure gradient dropped from 38 to 18 mm Hg. The clinical status of the patient improved substantially during the following days. However, the patient died on day 11 after the procedure because of sudden onset of acute respiratory distress arising from acute nosocomial fungus and cytomegalovirus infection worsened by his primary immunoincompetence. Autopsy demonstrated a totally patent shunt without superficial thrombus. Microscopically, a thin endothelial layer on the inner shunt surface was found to be present. (orig.).

  9. Educational activities regarding exposure reduction in interventional radiology

    International Nuclear Information System (INIS)

    Tajima, Osamu; Yabe, Hitoshi; Katoh, Kyoichi; Ueki, Junko; Nakamura, Kimiyuki; Nakatani, Akira; Wakamatsu, Osamu; Satoh, Tsugio; Nakazawa, Yasuo

    2000-01-01

    As interventional radiology (IVR) has become widespread recently, skin injury caused by exposure to radiation have been reported in academic meetings, and are a major concern in academic circles. In 1986, The Japanese Society of Circulation Imaging Technology (CITEC)'s organized a group to engage in an actual condition survey on cineangiography. We have studied exposed doses to patients in the event of cardiac catheterization using ancate data available in Japan and made efforts to spread methods of reducing exposure doses through academic meetings and medical journal. In 1998, we set up the Radiation Exposure Control Committee. The committee's objectives were to reduce exposure doses to patients and operators during cardiovascular examinations, and establish concrete of technical methods and protection guidelines for exposed dose reduction. We have studied presentations at academic meetings and study meetings, etc., and classified the results into the following 5 categories: methods of reducing radiation by X-ray equipment, methods of reducing exposure using X-ray protection devices, exposure dosimetry, clinical cases of radiation exposure, and QC, QA. The committee issued a textbook based on the reports and have educated, guided and enlightened radiological technologists, nurses and ME by holding the 'Seminar for reduction technique of radiation exposure in circulator organs.' (author)

  10. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  11. Endovascular interventions for multiple trauma

    International Nuclear Information System (INIS)

    Kinstner, C.; Funovics, M.

    2014-01-01

    In recent years interventional radiology has significantly changed the management of injured patients with multiple trauma. Currently nearly all vessels can be reached within a reasonably short time with the help of specially preshaped catheters and guide wires to achieve bleeding control of arterial und venous bleeding. Whereas bleeding control formerly required extensive open surgery, current interventional methods allow temporary vessel occlusion (occlusion balloons), permanent embolization and stenting. In injured patients with multiple trauma preinterventional procedural planning is performed with the help of multidetector computed tomography whenever possible. Interventional radiology not only allows minimization of therapeutic trauma but also a considerably shorter treatment time. Interventional bleeding control has developed into a standard method in the management of vascular trauma of the chest and abdomen as well as in vascular injuries of the upper and lower extremities when open surgical access is associated with increased risk. Additionally, pelvic trauma, vascular trauma of the superior thoracic aperture and parenchymal arterial lacerations of organs that can be at least partially preserved are primarily managed by interventional methods. In an interdisciplinary setting interventional radiology provides a safe and efficient means of rapid bleeding control in nearly all vascular territories in addition to open surgical access. (orig.) [de

  12. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    Energy Technology Data Exchange (ETDEWEB)

    Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross [Oxford University Hospitals, John Radcliffe Hospital, Department of Radiology (United Kingdom); Chalmers, Nicholas [Manchester Royal Infirmary, Department of Radiology (United Kingdom); Allgar, Victoria [University of York, Hull and York Medical School (United Kingdom)

    2013-12-15

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter

  13. Pediatric radiology in oto-rhino-laryngology

    OpenAIRE

    von Kalle, T; Koitschev, A

    2014-01-01

    [english] Head and neck diseases in children and adolescents present special diagnostic and differential diagnostic challenges to ENT surgeons as well as to radiologists. Both disciplines have to adapt the latest radiological and interventional technologies to the needs of the pediatric patient in order to enable a minimally invasive but successful diagnostic procedure.High quality sonography by an experienced examiner is often the only imaging technique that is necessary in children and adol...

  14. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong

    2017-01-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  15. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)

    2017-10-15

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  16. The Ethics for Justification of Radiological Procedures

    International Nuclear Information System (INIS)

    Corbett, R.H.

    2008-01-01

    There has been a steady and continuing interest in ethical issues in radiation protection for a number of years. The International Radiation Protection Association (IRPA) has produced a Code of Ethics which was adopted at its last General assembly. Many RP Societies have similar Codes. However, the trend now is the application of ethics to more practical day to day matters. This paper will concentrate of the application of ethics in the field of Justification in Radiation Protection in Medicine. A description of basic ethical concepts will be given, together with some discussion of the application of ethics to the proposed new recommendations from the International Commission for Radiation Protection (ICRP). The paper will conclude with a more detailed discussion of the ethical process of requesting radiological procedures, particularly in line with European Commission Regulations (Directives) and how they can and should be applied locally. To assist participants, an extensive list of references is appended here

  17. Cost-effectiveness of trauma CT in the trauma room versus the radiology department: the REACT trial

    Energy Technology Data Exchange (ETDEWEB)

    Saltzherr, T.P.; Goslings, J.C. [Academic Medical Center, Trauma Unit Department of Surgery, Amsterdam (Netherlands); Bakker, F.C. [VU University Medical Center, Department of Traumatology, Amsterdam (Netherlands); Beenen, L.F.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Olff, M. [Academic Medical Center, AMC de Meren, Department of Psychiatry, Amsterdam (Netherlands); Meijssen, K. [VU University Medical Center, Economics Department, Amsterdam (Netherlands); Asselman, F.F. [Academic Medical Center, Concern Staff Department, Amsterdam (Netherlands); Reitsma, J.B. [Academic Medical Center, Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam (Netherlands); Dijkgraaf, M.G.W. [Academic Medical Center, Clinical Research Unit, Amsterdam (Netherlands); Collaboration: on behalf of the REACT study group

    2013-01-15

    To determine the cost-effectiveness of trauma room CT compared with CT performed at the radiology department. In this randomised controlled trial, adult patients requiring evaluation in a level 1 trauma centre were included. In the intervention hospital the CT system was located within the trauma room and in the control hospital within the radiology department. Direct and indirect medical costs of the institutionalised stay and diagnostic and therapeutic procedures were calculated. A total of 1,124 patients were randomised with comparable demographic characteristics. Mean number of non-institutionalised days alive was 322.5 in the intervention group (95 % CI 314-331) and 320.7 in the control group (95 % CI 312.1-329.2). Mean costs of diagnostic and therapeutic procedures per hospital inpatient day were EUR554 for the intervention group and EUR468 for the control group. Total mean costs in the intervention group were EUR16,002 (95 % CI 13,075-18,929) and EUR16,635 (95 % CI 13,528-19,743) for the control group (P = 0.77). The present study showed that in trauma patients the setting with a CT system located in the trauma room did not provide any advantages or disadvantages from a health economics perspective over a CT system located in the radiology department. (orig.)

  18. Cost-effectiveness of trauma CT in the trauma room versus the radiology department: the REACT trial

    International Nuclear Information System (INIS)

    Saltzherr, T.P.; Goslings, J.C.; Bakker, F.C.; Beenen, L.F.M.; Olff, M.; Meijssen, K.; Asselman, F.F.; Reitsma, J.B.; Dijkgraaf, M.G.W.

    2013-01-01

    To determine the cost-effectiveness of trauma room CT compared with CT performed at the radiology department. In this randomised controlled trial, adult patients requiring evaluation in a level 1 trauma centre were included. In the intervention hospital the CT system was located within the trauma room and in the control hospital within the radiology department. Direct and indirect medical costs of the institutionalised stay and diagnostic and therapeutic procedures were calculated. A total of 1,124 patients were randomised with comparable demographic characteristics. Mean number of non-institutionalised days alive was 322.5 in the intervention group (95 % CI 314-331) and 320.7 in the control group (95 % CI 312.1-329.2). Mean costs of diagnostic and therapeutic procedures per hospital inpatient day were EUR554 for the intervention group and EUR468 for the control group. Total mean costs in the intervention group were EUR16,002 (95 % CI 13,075-18,929) and EUR16,635 (95 % CI 13,528-19,743) for the control group (P = 0.77). The present study showed that in trauma patients the setting with a CT system located in the trauma room did not provide any advantages or disadvantages from a health economics perspective over a CT system located in the radiology department. (orig.)

  19. Inpatient Complexity in Radiology-a Practical Application of the Case Mix Index Metric.

    Science.gov (United States)

    Mabotuwana, Thusitha; Hall, Christopher S; Flacke, Sebastian; Thomas, Shiby; Wald, Christoph

    2017-06-01

    With ongoing healthcare payment reforms in the USA, radiology is moving from its current state of a revenue generating department to a new reality of a cost-center. Under bundled payment methods, radiology does not get reimbursed for each and every inpatient procedure, but rather, the hospital gets reimbursed for the entire hospital stay under an applicable diagnosis-related group code. The hospital case mix index (CMI) metric, as defined by the Centers for Medicare and Medicaid Services, has a significant impact on how much hospitals get reimbursed for an inpatient stay. Oftentimes, patients with the highest disease acuity are treated in tertiary care radiology departments. Therefore, the average hospital CMI based on the entire inpatient population may not be adequate to determine department-level resource utilization, such as the number of technologists and nurses, as case length and staffing intensity gets quite high for sicker patients. In this study, we determine CMI for the overall radiology department in a tertiary care setting based on inpatients undergoing radiology procedures. Between April and September 2015, CMI for radiology was 1.93. With an average of 2.81, interventional neuroradiology had the highest CMI out of the ten radiology sections. CMI was consistently higher across seven of the radiology sections than the average hospital CMI of 1.81. Our results suggest that inpatients undergoing radiology procedures were on average more complex in this hospital setting during the time period considered. This finding is relevant for accurate calculation of labor analytics and other predictive resource utilization tools.

  20. Patient-oriented presentation of results of radiological procedures using DICOM-compliant DVD media

    Science.gov (United States)

    Ratib, Osman M.; Aberle, Denise R.; Goldin, Jonathan G.; Lu, David S.; Dahlbom, Magdalena; McGill, D. Ric; McCoy, J. Michael

    2003-05-01

    Some institutions have adopted digital media such as CD ROMs to provide patients and referring physicians with results of radiological procedures. These systems require a computer to review the images and lack the supporting explanations and guidance for patients to properly understand the results. We developed a hybrid DVD encoding format that combines DICOM-compliant image storage format with video streams viewable on any consumer DVD players. The addition of the video material allows radiologists to provide explanations, disclaimers and guidance to the patients regarding the results of the study. The diagnostic report is also included on the DVD as a PDF file and as a set of video frames that can be viewed on a DVD player. The native high-resolution images are also included in DICOM format on the DVD and can be accessed by any workstation equipped with a DICOM viewer. The DVD that can be reviewed on any consumer DVD player overcomes the limitation of CD ROMS that require the use of a personal computer. The results of the radiological procedures become more accessible patients that could be reluctant or unable to use a computer. Also, live video clips add a more personalized note and allow radiologists to convey important messages to the patients. This is particularly useful for self-referred screening procedures where results should always be accompanied with education material and explanations of the findings.

  1. Distance factor on reducing scattered radiation risk during interventional fluoroscopy

    International Nuclear Information System (INIS)

    Husaini Salleh; Mohd Khalid Matori; Muhammad Jamal Mat Isa; Zainal Jamaluddin; Mohd Firdaus Abdul Rahman; Mohd Khairusalih Mohd Zin

    2012-01-01

    Interventional Radiology (IR) is subspecialty of diagnostic radiology where minimally invasive procedures are performed using an x-ray as a guidance. This procedure can deliver high radiation doses to patient and medical staff compared with other radiological method due to long screening time. The use of proper shielding, shorten the exposure time and keep the distance are the practices to reduce scattered radiation risks to staff involve in this procedure. This project is to study the distance factor on reducing the scattered radiation effect to the medical staff. It also may provide the useful information which can be use to establish the scattered radiation profile during the IR for the sake of radiation protection and safety to the medical staff involved. (author)

  2. Current radiologic interventions in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Masoud, I.; Naeem, M.Q.T.; Saeed, F.; Mirza, S.A.M.; Khan, A.; Bhatti, M.A.

    2006-01-01

    With the rising incidence of chronic liver disease caused by viral hepatitis, hepatocellular carcinoma is showing a corresponding rise worldwide. Surgery remains the mainstay of treatment, but patients unfit for surgery or liver transplantation form the bulk of those presenting with this disease. Palliative treatments are being used to treat those and radiological modalities form the mainstay of the treatment. Radiology plays a major role in the diagnosis, treatment and follow-up of hepatocellular carcinoma. Current radiological treatment modalities include percutaneous ethanol ablation, radiofrequency ablation and trans-arterial chemoembolization. This update highlights the recent advancements in the field and compares their relative merits and demerits. (author)

  3. Radiation protection in the intervenmtional radiology; Strahlenschutz in der interventionellen Radiologie

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Benjamin V. [Institut fuer Radiobiologie der Bundeswehr, Muenchen (Germany); Ulm Univ. (Germany); Lissek, Friedrich; Waldeck, Stephan [Bundeswehrzentralkrankenhaus Koblenz (Germany). Klinik fuer Radiologie und Neuroradiologie

    2017-07-01

    Interventional radiology and neuroradiology covers a variety of diagnostic and therapeutic methods. A minimal invasive percutaneous access under imaging guidance is common for all these methods. The legal regulations for quality assurance are reviewed, technical possibilities for dose reduction and the importance of modern radiation protection procedures are discussed.

  4. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  5. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  6. Impact on Patient Safety and Satisfaction of Implementation of an Outpatient Clinic in Interventional Radiology (IPSIPOLI-Study): A Quasi-Experimental Prospective Study

    International Nuclear Information System (INIS)

    Lutjeboer, Jacob; Burgmans, Mark Christiaan; Chung, Kaman; Erkel, Arian Robert van

    2015-01-01

    PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (control group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures

  7. Impact on Patient Safety and Satisfaction of Implementation of an Outpatient Clinic in Interventional Radiology (IPSIPOLI-Study): A Quasi-Experimental Prospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Lutjeboer, Jacob, E-mail: j.lutjeboer@lumc.nl; Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl, E-mail: mburgmans@hotmail.com; Chung, Kaman, E-mail: kaman.chung10@gmail.com; Erkel, Arian Robert van, E-mail: a.r.van-erkel@lumc.nl [Leiden University Medical Center, Department of Radiology (Netherlands)

    2015-06-15

    PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (control group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures.

  8. Deepening the reform of medical education, strengthening the training of reserve specialists in interventional radiology: a profound rethinking based on a survey of medical students

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Li Linsun

    2010-01-01

    Although the interventional radiology, a rapidly expanding medical specialty, has already been widely popularized and generally accepted for many years, it is still facing lots of challenges and turf wars, such as the brain drain, understaffed and the gap between the old and the young. This article attempts to analyze the reasons through investigating the current teaching situation of interventional radiology in medical colleges and finding out the undergraduates' attitude to interventional radiology, in order to explore possible paths for solving the imbalance between supply and demand of qualified personnel. (authors)

  9. EU-CIS joint study project 2. Intervention criteria in CIS, risk assessments and non-radiological factors in decision-making

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P. [Risoe National Lab., Roskilde (Denmark); Demin, V.F. [Russian Reserch Centre `Kurchatov Inst.`, Moscow (Russian Federation); Konstantinov, Y.O. [Research Inst. of Radiation Hygiene, St. Petersburg (Russian Federation); Likhtarev, I.A. [Ukrainian Scientific Centre for Radiation Medicine, Kiev (Ukraine); Rolevich, I.V. [Chernobyl State Commiettee, Minsk (Belarus); Schneider, T. [Centre d`etudes sur l`Evaluation de la Protection dans le domaine Nucleaire, CEPN, Paris (France)

    1996-05-01

    An extensive radiation risk estimation methodology has recently been developed in Russia and used for estimates of risk in exposed populations in the republics of Russia, Belarus and Ukraine. Results based on demographic data for the three republics are presented and compared with risk estimates from the EU risk model ASQRAD. The intervention criteria in the CIS republics have been evolving since the Chernobyl accident. The development of criteria in each of the three republics has been analysed and the CIS-Criteria have been compared to international guidance on intervention. After a nuclear or radiological emergency both radiological and non-radiological protection factors will influence the level of protective actions being introduced. The role of non-radiological protection factors in the overall optimization of health protection is addressed. It is argued that optimization of the overall health protection is not a question of developing radiation radiation protection philosophy to fully include socio-psychological factors. It is rather a question of including these factors - in parallel with the radiological protection factors - in cooperation between radiation protection experts and psychological specialists under the responsibility of the decision maker. (au) 19 tabs., 10 ills., 45 refs.

  10. EU-CIS joint study project 2. Intervention criteria in CIS, risk assessments and non-radiological factors in decision-making

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Demin, V.F.; Konstantinov, Y.O.; Likhtarev, I.A.; Rolevich, I.V.; Schneider, T.

    1996-05-01

    An extensive radiation risk estimation methodology has recently been developed in Russia and used for estimates of risk in exposed populations in the republics of Russia, Belarus and Ukraine. Results based on demographic data for the three republics are presented and compared with risk estimates from the EU risk model ASQRAD. The intervention criteria in the CIS republics have been evolving since the Chernobyl accident. The development of criteria in each of the three republics has been analysed and the CIS-Criteria have been compared to international guidance on intervention. After a nuclear or radiological emergency both radiological and non-radiological protection factors will influence the level of protective actions being introduced. The role of non-radiological protection factors in the overall optimization of health protection is addressed. It is argued that optimization of the overall health protection is not a question of developing radiation radiation protection philosophy to fully include socio-psychological factors. It is rather a question of including these factors - in parallel with the radiological protection factors - in cooperation between radiation protection experts and psychological specialists under the responsibility of the decision maker. (au) 19 tabs., 10 ills., 45 refs

  11. Generic procedures for monitoring in a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    2005-03-01

    This book is a Japanese version of the International Atomic Energy Agency (IAEA) publication (Report No., IAEA-TECDOC-1092, published in Vienna, 1999) of the same title. The translation of the original English into Japanese was done by the Department of Dose Assessment, Research Center for Radiation Emergency Medicine, National Institute of Radiological Sciences (NIRS). Since the Department was organized in addition to the Emergency Medicine Dept. in the Center in 2003 to establish a system for rapid and accurate dose assessment at emergent radiation exposure, the translation is thus a result of the department works, and is published with permission by IAEA as one of a series of NIRS Report (NIRS-M--179) for use in the country. The book is essentially a manual for providing technical requirements and procedures for radiation monitoring, environmental sampling and laboratory analyses for a nuclear or other radiological emergency. The contents are: Introduction, Outline of monitoring, Monitoring of outdoor radiation and contamination, Outdoor sampling, Gross alpha/beta measurement, Gamma spectrometry, Activation analyses, Basic data assessment, Work-sheets, Check-list for measuring equipments, Appendices, References, and others. (S.I.)

  12. A novel combined interventional radiologic and hepatobiliary surgical approach to a complex traumatic hilar biliary stricture

    Directory of Open Access Journals (Sweden)

    Rachel E. NeMoyer

    Full Text Available Introduction: Benign strictures of the biliary system are challenging and uncommon conditions requiring a multidisciplinary team for appropriate management. Presentation of case: The patient is a 32-year-old male that developed a hilar stricture as sequelae of a gunshot wound. Due to the complex nature of the stricture and scarring at the porta hepatis a combined interventional radiologic and surgical approach was carried out to approach the hilum of the right and left hepatic ducts. The location of this stricture was found by ultrasound guidance intraoperatively using a balloon tipped catheter placed under fluoroscopy in the interventional radiology suite prior to surgery. This allowed the surgeons to select the line of parenchymal transection for best visualization of the stricture. A left hepatectomy was performed, the internal stent located and the right hepatic duct opened tangentially to allow a side-to-side Roux-en-Y hepaticojejunostomy (a Puestow-like anastomosis. Discussion: Injury to the intrahepatic biliary ductal confluence is rarely fatal, however, the associated injuries lead to severe morbidity as seen in this example. Management of these injuries poses a considerable challenge to the surgeon and treating physicians. Conclusion: Here we describe an innovative multi-disciplinary approach to the repair of this rare injury. Keywords: Combined approach, Interventional radiology, Hepatobiliary surgery, Complex traumatic hilar biliary stricture, Case report

  13. Management and presentation of grouped procedures: has the IHE integration profile cracked the toughest radiology workflow nut?

    Science.gov (United States)

    Parisot, Charles R.; Channin, David S.; Avrin, David E.; Lindop, Christopher

    2001-08-01

    In a simple, typical radiology workflow process, an order generates a single procedure, which in turn generates a single data set, from which, one radiology report is generated. There are, however, occasions when a single order consists of more than one procedure each with a separate report, yet the procedures are accomplished by one physical acquisition of data. The prototypical example of this is the request for computed tomographic evaluation of the chest, abdomen and pelvis. The study is accomplished, with modern day scanners, by a single helical acquisition, yet there are typically three codable and billable procedures involved, and these may be reported independently either for administrative or academic reasons. This grouping of procedures remained up to now a challenge to automate across integrated modalities, PACS and RIS. This paper discusses a number of other practical cases where this situation occurs and reviews the capabilities of the Presentation of Grouped Procedures IHE Integration Profile in solving this problem. The DICOM services used are evaluated as well as the strengths and weaknesses of this IHE Integration Profile. The implementation experience gained on both a CT and an MR for the IHE Demonstration at RSNA 2000 and HIMSS 2001 is also reviewed. In conclusion, the resulting clinical and operational benefits are discussed.

  14. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  15. Joint WHO/ISH workshop on efficacy and radiation safety in interventional radiology

    International Nuclear Information System (INIS)

    Baeuml, A.; Bauer, B.; Bernhardt, J.H.; Stieve, F.E.; Veit, R.; Zeitlberger, I.

    1997-02-01

    With the constantly developing technology and the opening of new fields of application, the implementation of Interventional Radiology (IR) is increasing considerably. These sophisticated procedures can frequently replace open surgery, and this is of enormous benefit for the patient. On the other hand, IR involves prolonged application of fluoroscopy and - due to the need for excellent image quality - partly very high dose-rate levels. Additionally, cine-series, and alsogreat numbers of single radiographs are necessary. Accordingly, the levels of exposure to patients and staff are very high. In order to consider possible reduction of the radiation risks of IR procedures interdiciplinary talks between representatives of manufacturers of X-ray equipment, hospital physicists and the clinical community would seem necessary in order to find ways of avoiding unproductive radiation exposure to the patient and to clinical staff. This was the aim of a workshop on IR, which was jointly organized by the World Health Organization and the Institute of Radiation Hygiene of the Federal Office for Radiation Protection in Germany in October 1995. It was intended as a forum for the discussion of issues related to IR, and to forster improved application, that is to say as an opportunity: To present the state of the art; to work out proposals for more efficient clinical protocols; to discuss on schemes of education and training and on equipment-related developments. Improvement of radiation safety for both patients and staff, was the general aim of the workshop. This volume contains the presentations given on the first day of the workshop. (orig./DG) [de

  16. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care; Wirtschaftliche Evaluation angiographischer Interventionen einschliesslich einer radiologischen stationaeren und ambulanten Patientenbetreuung

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  17. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  18. Number of radiological examinations in Finland in 2000

    CERN Document Server

    Hakanen, A

    2002-01-01

    STUK (Radiation and Nuclear Safety Authority) collected the number of radiological examinations in Finland in 2000. The work was based on a decree of the ministry of social affairs and health on the medical use of radiation. The work was done in cooperation with the Finnish work group of nomenclature of radiological examinations and procedures and professor Seppo Soimakallio. In 2000, ca. 4.1 million x-ray examinations were made in Finland. In 1984 and in 1995, the numbers were ca. 4.6 million and 4.2 million, respectively, indicating that the total number of x-ray examinations has remained nearly unaltered. The proportions of conventional x-ray examinations, computed tomography examinations, angiographic and interventional procedures were ca. 93.5 %, 5.0 %, 0.9 % and 0.6 %, respectively. The reported number of ultrasound examinations was ca. 0.5 million. The reported number of MRI examinations was ca. 0.1 million.

  19. Bureau of radiological health compliance testing procedures for cabinet S-ray systems

    International Nuclear Information System (INIS)

    Miller, E.A.; Sprau, D.

    1976-01-01

    A manual has been developed by the Bureau of Radiological Health of the Food and Drug Administration to establish procedures for the routine field testing of cabinet x-ray systems to determine compliance with the Federal Performance Standard for Cabinet X-Ray Systems, 21 CFR 1020.40. The manual provides specific instructions for testing each model of cabinet x-ray system. Results from the inspection are recorded on a data from which is designed to permit automatic data processing

  20. Nordic Intervention Criteria for Nuclear or Radiological Emergencies. Recommendations

    International Nuclear Information System (INIS)

    2001-01-01

    Recommendations of the Nordic radiation protection authorities on application of international criteria in a nuclear or radiological emergency in the Nordic countries are presented. The recommendations are focused on the generic intervention levels for various actions to protect members of the public and workers undertaking an intervention. Prompt precautionary actions for the near zones around the Finnish and Swedish nuclear power plants are defined. These actions are; preventive sheltering, iodine prophylaxis and precautionary evacuation. No special intervention levels for these precautionary actions have been set, because implementation of these actions is always based on very limited information about an accident. These actions can be initiated on a mere indication of possible release of radioactivity. The indication might be an alarm or any other predefined signal. Intervention level for actions to protect members of the public are based on the concept of avertable dose. They are in line with the international recommendations. With regard to iodine prophylaxis, a national approach is recommended due to different national policies of advance distribution of iodine tablets. The longer term intervention actions, temporary relocation and permanent resettlement, will be based not only on radiation protection factors but also on wider judgement of the overall situation. For that reason, no generic intervention levels, in terms of radiation dose, are recommended. The intervention levels for various protective actions are in the following table.Table 1. Generic intervention levels for actions to protect members of the public.Protective action. Generic intervention level as an avertable dose. Sheltering: 10 mSv within two days (effective dose); Iodine prophylaxis: National recommendations; Evacuation: 50 mSv within one week (effective dose); Temporary relocation: No predetermined intervention level; Permanent resettlement: No predetermined intervention level. Workers

  1. Analysis of dose to crystalline in Interventional radiology: a purpose of one case; Analisis de dosis a cristalino en Radiologia intervencionista: a proposito de un caso

    Energy Technology Data Exchange (ETDEWEB)

    Carrera M, F.; Moreno R, F.; Velazquez M, F.; Manzano M, F.J.; Moreno S, T. [Hospital `Juan Ramon Jimenez` Ronda Norte s/n 21005. Huelva, Espana (Spain)

    1998-12-31

    The present work shows the dose values to crystalline for the personnel which works in interventional radiology procedures. It was took data of 436 studies with a total of 2,133.4 minutes in fluoroscopy and 19,563 images. It was showed dose values to crystalline in three situations: without blinding, with blinding of 0.25 and 0.50 mm Pb and by type of study: fluoroscopy, graphie and total. The dose means and ranges to patient for each of these studies also are detailed. (Author)

  2. Protection of the unborn child in diagnostic and interventional radiological procedures; Schutz des ungeborenen Lebens bei diagnostischen und interventionellen radiologischen Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Hojreh, A.; Prosch, H.; Karanikas, G.; Trattnig, S. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria); Homolka, P. [Medizinische Universitaet Wien, Zentrum fuer medizinische Physik und biomedizinische Technik, Wien (Austria)

    2015-08-15

    The radiation exposure of an unborn child should be principally avoided, whenever it is medically reasonably possible; therefore, the identification of pregnant patients is the first and the most important step in radiation protection of the unborn child. However, in cases of emergency saving the life of the patient has a higher priority than the radiation protection of the unborn child. In this review article, we present a longitudinal section through the national and international literature and guidelines as a basis for radiological management of a (possibly) pregnant patient. We also list some radiological procedures recommended in the literature for a series of maternal indications considering the contraindications of each method during pregnancy and radiation protection of the unborn child. (orig.) [German] Die Strahlenexposition eines ungeborenen Kindes ist prinzipiell, wann immer dieses medizinisch sinnvoll moeglich ist, zu vermeiden. Daher ist die Identifizierung der schwangeren Patientinnen der erste und wichtigste Schritt zum Strahlenschutz des ungeborenen Kindes. In einer Notfallsituation hat allerdings das Leben der Patientin hoechste Prioritaet. In dieser Uebersichtsarbeit praesentieren wir einen Laengsschnitt durch die nationale und internationale Literatur und Leitlinien, die als Grundlage fuer das radiologische Management einer (moeglicherweise) schwangeren Patientin angewendet werden kann. Wir stellen auch einige in der Literatur empfohlene radiologische Verfahren fuer eine Reihe von Indikationen in der Schwangerschaft vor. Dabei werden sowohl die Kontraindikationen der jeweiligen Methode waehrend der Schwangerschaft als auch der Strahlenschutz des ungeborenen Kindes beruecksichtigt. (orig.)

  3. Utilization of a modified Clavien Classification System in reporting complications after ultrasound-guided percutaneous nephrostomy tube placement: comparison to standard Society of Interventional Radiology practice guidelines.

    Science.gov (United States)

    Degirmenci, Tansu; Gunlusoy, Bulent; Kozacioglu, Zafer; Arslan, Murat; Ceylan, Yasin; Ors, Bumin; Minareci, Suleyman

    2013-06-01

    To report our results on percutaneous nephrostomy (PCN) and classify our complications with the Standard of Practice Committee of the Society of Interventional Radiology guidelines and the modified Clavien Classification System (CCS). Three hundred eighty-nine PCN insertions were performed in 322 patients (224 men and 98 women) at our institution. PCN insertion was performed under ultrasound for dilated pelvicalyceal system and ultrasound/fluoroscopy for nondilated system. PCN was considered successful if the catheter was drained urine spontaneously. Number of complications was registered. Primary successful PCN insertion was achieved in 368 of the 389 procedures (94.6%). The success rates for nondilated and dilated systems were 82.7% and 96.4%, respectively. Major complications occurred in 9.6% and minor complications in 9.9% according to the Society of Interventional Radiology. According to the modified CCS grades I, II, III, IV, and V was 9.9%, 1.2%, 6.8%, 1.2%, and 0.3%, respectively. Age, grade of the hydronephrosis, serum creatinine levels, and mean hemoglobin levels were statistically significant parameters for the occurrence of complications on univariate analysis. The nondilated system has statistically significant parameters affecting the complication rates on multivariate analysis (P = .001, odds ratio [OR] = 6.1, 95% confidence interval [CI] = 2-18.4). Percutaneous nephrostomy is a well-known procedure in the treatment of temporary or permanent drainage of an obstructed system. It is very important to define the complications related to interventions for interpretation of clinical comparisons more accurately. Modified CCS is a reproducible system to evaluate the complications. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  5. Handling of overexposed persons in radiological emergencies

    International Nuclear Information System (INIS)

    Estrada, E.

    2000-01-01

    The purpose of this standard procedure of the criteria in case of radiological emergencies is to describe the standard procedures used to define an radiological accident in terms of the doses received, and to describe the medical procedures for diagnoses and treatment of health hazards caused by external and internal irradiation in radiological emergencies

  6. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    International Nuclear Information System (INIS)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I.; Barquinero, J.F.; Rodriguez, P.; Barrios, L.; Verdu, G.; Ramos, M.

    2006-01-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  7. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    Energy Technology Data Exchange (ETDEWEB)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I. [Hospital Univ. la Fe de Valen cian, Servicio de Proteccion Radiologica, Valencia (Spain); Barquinero, J.F.; Rodriguez, P. [Universitat Autonom a de Barcelona, Servicio de Dosimetria Biologica, Unidad de Antropologia, Departamento de Biologia Animal, Vegetal y Ecologia., Barcelona (Spain); Barrios, L. [Universidad Autonoma de Barcelona, Dept. de Biologia Celular y Fisiologia. Unidad de Biologia Celular, Barcelona (Spain); Verdu, G.; Ramos, M. [Universidad Politecnica de Valencia, Dept. de Ingenieria Quimica y Nuclear, Valencia, (Spain)

    2006-07-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  8. Generic procedures for monitoring in a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    1999-06-01

    One of the most important aspects of managing a radiological emergency is the ability to promptly and adequately assess the need for protective actions. Protective action accident management must make use of the key relevant information available. Decision-making and accident assessment will be an iterative and dynamic process aimed at refining the initial evaluation as more detailed and complete information becomes available. Emergency monitoring is one of the main sources for obtaining needed information. This publication is in the scope of the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency (Legal Series No. 14) under which the IAEA is authorized to assist a State Party or a Member State among other matters in developing appropriate radiation monitoring programmes, procedures and standards (Article 5). The scope of this manual is restricted to practical guidance for environmental and source monitoring during a nuclear or other radiological emergency. It does not address emergency response preparedness, nor does it cover the emergency management aspects of accident assessment. This manual is organised into sections relating to measurements in order of priority of a major reactor accident, namely: ambient gamma/beta dose rates from plume, ground deposition or source; radionuclide concentrations in air; deposition maps for 131 I and 137 Cs and other important radionuclides; radionuclide mix in deposition and radionuclide concentrations in food, drinking water and other samples. The introductory section provides an overview of the design of emergency monitoring and sampling programmes, monitoring teams and their qualifications and training, monitoring equipment and instrumentation, protective actions for emergency monitoring teams and quality assurance and quality control checks

  9. Hospital organization and importance of an interventional radiology inpatient admitting service: Italian single-center 3-year experience.

    Science.gov (United States)

    Simonetti, Giovanni; Bollero, Enrico; Ciarrapico, Anna Micaela; Gandini, Roberto; Konda, Daniel; Bartolucci, Alberto; Di Primio, Massimiliano; Mammucari, Matteo; Chiocchi, Marcello; D'Alba, Fabrizio; Masala, Salvatore

    2009-03-01

    In June 2005 a Complex Operating Unit of Interventional Radiology (COUIR), consisting of an outpatient visit service, an inpatient admitting service with four beds, and a day-hospital service with four beds was installed at our department. Between June 2005 and May 2008, 1772 and 861 well-screened elective patients were admitted to the inpatient ward of the COUIR and to the Internal Medicine Unit (IMU) or Surgery Unit (SU) of our hospital, respectively, and treated with IR procedures. For elective patients admitted to the COUIR's inpatient ward, hospital stays were significantly shorter and differences between reimbursements and costs were significantly higher for almost all IR procedures compared to those for patients admitted to the IMU and SU (Student's t-test for unpaired data, p money and obtain positive margins (differences between reimbursements and costs). During 3 years of activity, the inpatient admitting service of our COUIR yielded a positive difference between reimbursements and effective costs of 1,009,095.35 euros. The creation of an inpatient IR service and the admission of well-screened elective patients allowed short hospitalization times, reduction of waiting lists, and a positive economic outcome.

  10. Shielding effect of lead glasses on radiologists' eye lens exposure in interventional procedures

    International Nuclear Information System (INIS)

    Hu, Panpan; Kong, Yan; Chen, Bo; Liu, Qianqian; Zhuo, Weihai; Liu, Haikuan

    2017-01-01

    To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm"2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm"2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm"2 per glass) lens are recommended (authors)

  11. Medical intervention in radiological emergencies, formation and training

    International Nuclear Information System (INIS)

    Cardenas H, J.

    2006-01-01

    The work exposes the national experience in the development of training programs in medical aspects of the radiological emergencies. Implemented after valuing the existent situation, identified the necessities and the reach of the training, additionally it was elaborated the content of the training program whose purpose is guided to the invigoration of the medical answer capacity in radiological emergencies The content of the modular program it approaches theoretical- practical aspects on preparation and medical answer in radiological emergencies. The program includes an exercise that simulates a radiological accident, to evaluate during the same one, the answer capacity before this situation. The training concludes with the design of a strategy for the preparation and answer in radiological emergencies in correspondence with the potential accidental scenarios that the participants can face. (Author)

  12. Professional development for radiographers and post graduate nurses in radiological interventions: Building teamwork and collaboration through drama.

    Science.gov (United States)

    Lundén, M; Lundgren, S M; Morrison-Helme, M; Lepp, M

    2017-11-01

    The rapid development within Interventional Radiology presents new challenges. Hybrid operating rooms consist of interventional radiology, open surgery, computed tomography, magnetic resonance imaging and other techniques. This means that several disciplines and professionals need to work in new constellations creating a multidisciplinary team around the patient. In accordance with this development, higher professional education must provide new pedagogic strategies to successfully address the knowledge expected in today's complex working life. To explore the use of Applied Drama as a learning medium, focusing on the use of Forum Theatre, to foster team work and collaboration in the field of radiography and learning. A qualitative approach, closely related to Ethnography, was utilized. The Drama Workshop utilising Forum Theatre created a dynamic learning environment and enabled the participants from three professions to understand each other's priorities better. The use of drama within health care education allows the students to take different roles in order to find the best way to co-operate. Forum Theatre is a useful learning medium in order to promote teamwork and collaboration in the radiological intervention field. By choosing a personal working experience, Forum Theatre seem to engage the participants at a deeper level and to experience various communication strategies and how the outcome changed depending on the approach. This can lead to improved teamwork and collaboration. Copyright © 2017 The College of Radiographers. All rights reserved.

  13. Radiological survey activities: uranium mill tailings remedial action project procedures manual

    International Nuclear Information System (INIS)

    Little, C.A.; Berven, B.A.; Carter, T.E.

    1986-07-01

    The US Department of Energy (DOE) was assigned the responsibility for conducting remedial action at 24 sites, which are located in one eastern and nine western states. The DOE's responsibilities are being met through its Uranium Mill Tailings Remedial Action Project Office (UMTRA-PO) in Albuquerque, New Mexico. The purpose of this Procedures Manual is to provide a standardized set of procedures that document in an auditable manner the activities performed by the Radiological Survey Activities (RASA) group in the Dosimetry and Biophysical Transport Section (DABTS) of the Health and Safety Research Division (HASRD) at the Oak Ridge National Laboratory (ORNL), in its role as the Inclusion Survey Contractor (ISC). Members of the RASA group assigned to the UMTRA Project are headquartered in the ORNL/RASA office in Grand Junction, Colorado, and report to the ORNL/RASA Project Manager. The Procedures Manual ensures that the organizational, administrative, and technical activities of the RASA/UMTRA group conform properly to those of the ISC as described in the Vicinity Properties Management and Implementation Manual and the Summary Protocol. This manual also ensures that the techniques and procedures used by the RASA/UMTRA group and contractor personnel meet the requirements of applicable governmental, scientific, and industrial standards

  14. Extremity doses to interventional radiologists

    International Nuclear Information System (INIS)

    Wihtby, M.; Martin, C. J.

    2002-01-01

    Radiologists performing interventional procedures are often required to stand close to the patient's side when carrying out manipulations under fluoroscopic control. This can result in their extremities receiving a high radiation dose, due to scattered radiation. These doses are sometimes high enough to warrant that the radiologist in question be designated a classified radiation worker. Classification in the UK is a result of any worker receiving or likely to receive in the course of their duties in excess of 3/10ths of any annual dose limit (500mSv to extremities, skin). The doses to the legs of radiologists have received less attention than those to the hands, however the doses may be high, due to the proximity of the legs and feet to scattered radiation. The legs can be exposed to a relatively high level of scattered radiation as the radiation in produced from scatter of the un attenuated beam from the bottom of the patient couch. The routine monitoring of extremity doses in interventional radiology is difficult due to several factors. Firstly a wide range of interventional procedures in undertaken in every radiology department, and these procedures require many different techniques, equipment and skills. This means that the position the radiologist adopts in relation to scattering medium and therefore their exposure, depends heavily on the type of procedure. As the hands which manipulate the catheters within the patient are often located close to the patients side and to the area under irradiation, the distribution of dose across the hands can be variable, with very high localised doses, making routine monitoring difficult. The purpose of this study was to determine the magnitude and distribution of dose to the hands and legs of interventional radiologists carrying out a wide range of both diagnostic and therapeutic interventional procedures. To ascertain the most effective method of monitoring the highest dose in accordance with the Basic safety standards

  15. Establishing an individual dosing system for patients undergoing interventional transcatheter arterial embolization: Radiochromic film and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Tsai, Hui-Yu; Lai, Pei-Ling; Li, Yang-Ying; Tyan, Yeu-Sheng

    2011-01-01

    Less invasive imaging-guided vascular interventions with fluoroscopy and digital subtraction angiography have recently become widespread and have been successfully used for treating various diseases. However, interventional fluoroscopy procedures may present deterministic and stochastic radiation risks. The International Commission on Radiological Protection (ICRP) and the Food and Drug Administration have requested identifying procedures that may involve patient doses greater than the recommended thresholds. In this study, radiochromic dosimetric media, known as self-developing films, and measurement-based Monte Carlo simulations were used to establish an interventional radiology dosing system for individual patients undergoing interventional transcatheter arterial embolization. The peak skin dose, evaluated from the entrance surface dose distribution, was 21% less than the cumulated dose reported from the console. A 3D dose map incorporated into CT images was established. The organ doses and effective doses for individual patients were evaluated using this dosing system. This system could be applied very well to other fluoroscopic or interventional procedures for patient dose management.

  16. A database structure for radiological optimization analyses of decommissioning operations

    International Nuclear Information System (INIS)

    Zeevaert, T.; Van de Walle, B.

    1995-09-01

    The structure of a database for decommissioning experiences is described. Radiological optimization is a major radiation protection principle in practices and interventions, involving radiological protection factors, economic costs, social factors. An important lack of knowledge with respect to these factors exists in the domain of the decommissioning of nuclear power plants, due to the low number of decommissioning operations already performed. Moreover, decommissioning takes place only once for a installation. Tasks, techniques, and procedures are in most cases rather specific, limiting the use of past experiences in the radiological optimization analyses of new decommissioning operations. Therefore, it is important that relevant data or information be acquired from decommissioning experiences. These data have to be stored in a database in a way they can be used efficiently in ALARA analyses of future decommissioning activities

  17. Diagnostic radiology on multiple injured patients: interdisciplinary management

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Pfeifer, K.J.; Kanz, K.G.; Mutschler, W.

    2001-01-01

    The presence of a radiologist within the admitting area of an emergency department and his capability as a member of the trauma team have a major impact on the role of diagnostic radiology in trauma care. The knowledge of clinical decision criteria, algorithms, and standards of patient care are essential for the acceptance within a trauma team. We present an interdisciplinary management concept of diagnostic radiology for trauma patients, which comprises basic diagnosis, organ diagnosis, radiological ABC, and algorithms of early clinical care. It is the result of a prospective study comprising over 2000 documented multiple injured patients. The radiologist on a trauma team should support trauma surgery and anesthesia in diagnostic and clinical work-up. The radiological ABC provides a structured approach for diagnostic imaging in all steps of the early clinical care of the multiple injured patient. Radiological ABC requires a reevaluation in cases of equivocal findings or difficulties in the clinical course. Direct communication of radiological findings with the trauma team enables quick clinical decisions. In addition, the radiologist can priority-oriented influence the therapy by using interventional procedures. The clinical radiologist is an active member of the interdisciplinary trauma team, not only providing diagnostic imaging but also participating in clinical decisions. (orig.) [de

  18. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  19. Evaluation of the occupational doses of interventional radiologists

    NARCIS (Netherlands)

    Kuipers, Gerritjan; Velders, Xandra L.; de Winter, Robbert J.; Reekers, Jim A.; Piek, Jan J.

    2008-01-01

    The aim of the present study was to determine whether there is a linear relation between the doses measured above and those measured under the lead apron of the radiologists performing interventional procedures. To monitor radiation exposure the International Commission of Radiological Protection

  20. Estimation of genetic risk and detriment in radiological vascular examinations in Malaga (Spain)

    International Nuclear Information System (INIS)

    Ruiz Cruces, R.; Perez Martinez, M.; Fernandez Vazquez, M.I.; Diez de los Rios Delgado, A.

    1997-01-01

    The objective of the study is to estimate the population undergoing procedures of interventional vascular radiology. The values of genetically significant dose, somatically significant dose and damage are presented. The determinations refer to the population of Malaga and calculate the values of the dose-area product, dose in organs and effective doses. At first glance, these complex explorations seem to provide dose rates which are much higher than those for simple examinations. However, our values demonstrate the contrary. The numbers contrast with the values obtained from simple examinations by the population. Although the reasons are multifactorial, the root cause is the average age of the patients which undergo interventional vascular radiology: they are much older than patients who undergo simple explorations

  1. Steadily promoting the technical research and the clinical application of interventional radiology for cervical spine

    International Nuclear Information System (INIS)

    Wu Chungen; Zhou Bing

    2009-01-01

    Many interventional procedures have been practiced in the treatment of cervical spine diseases for recent years. There are percutaneous biopsy, periradicular therapy for cervical never pain, percutaneous vertebroplasty and many kinds of intervertebral disc decompression. However, because of the manipulation difficulties and high risks of these procedures the popularization of interventional techniques in treating cervical spine disorders has actually been beset with difficulties. The main risks caused by interventional operation are puncture injuries and side-effect of therapeutic design. Therefore, how to reduce the procedure's risk is a great challenge to interventional radiologists as well as an urgent research task. (authors)

  2. Simulators in catheter-based interventional radiology: training or computer games?

    International Nuclear Information System (INIS)

    Gould, D.A.; Kessel, D.O.; Healey, A.E.; Johnson, S.J.; Lewandowski, W.E.

    2006-01-01

    Training in interventional radiology (IR) relies on a traditional apprenticeship; to protect patients, expert supervision is mandatory until knowledge, attitudes and practical skills have been certified as satisfactory. However, the current quality of IR training is threatened by reduced time for trainees to learn, as well as a loss of basic diagnostic, training cases to non-invasive imaging. At the same time, IR techniques are becoming a focus of interest to a range of other clinical specialities. To address this training shortfall there is a need to develop novel training alternatives such as simulator models. Few simulator models in any medical field have been successfully validated to show improved clinical skills in treating patients. To date no endovascular simulator has met this standard. A good simulator must be based around key performance measures (metrics) derived from careful analysis of the procedure to be replicated. Metrics can be determined by trained psychologists from a direct analysis of the content of the job or task to be tested. The identification of these critical measures of performance is a complex process which must be tailored to a training curriculum to be effective. Simulators based on flawed metrics will invariably lead to unsatisfactory assessment. It follows that simulator development must involve the statutory licensing authorities. Equally it is essential that we do not assume that training on a particular simulator will correlate with the ability to perform the task in the real world. This 'transfer of training' must be rigorously proven by validation studies

  3. Further promoting the clinical application and fundamental research for interventional radiology of urinary system

    International Nuclear Information System (INIS)

    Liang Huimin; Feng Gansheng

    2008-01-01

    Along with the rapid development of interventional radiology, a simultaneous increase of the treatment was carried out for diseases of urinary system, including nephrostomy, balloon dilatation and stenting for uninary tract obstruction, calculus removing techniques, stenting for prostatic hypertrophy; TAE/TACE and ablation therapy for benign/malignant tumors; angioplasty with balloon or stent for stenosis of renal artery or vein; embolotherapy for hemorrhagic diseases; interventional treatment for complications after renal transplantation, and so on. All the above mentioned techniques for urinary diseases have already provided with good results and futher research will bring a promising future. (authors)

  4. Proposed procedure and analysis of results to verify the indicator of the product dose-area in radiology equipment

    International Nuclear Information System (INIS)

    Garcia Marcos, R.; Gallego Franco, P.; Sierra Diaz, F.; Gonzalez Ruiz, C.; Rodriguez Checa, M.; Brasa Estevez, M.; Gomez Calvar, R.

    2013-01-01

    The aim of this work is to establish a procedure to verify the value of the product dose-area showing certain teams of Radiology, with an alternative to the use of external transmission cameras. (Author)

  5. Interventional method in diagnosis and treatment of vascular complication after liver transplantation

    International Nuclear Information System (INIS)

    Huang Yonghui; Yang Jianyong; Chen Wei; Zhuang Wenquan; Yu Shenping; Chen Guihua

    2001-01-01

    Objective: To evaluate the role of interventional method in the diagnosis and treatment of vascular complication after liver transplantation. Methods: Seven patients (3 vena cava stenosis, 1 hepatic artery stenosis, 2 hepatic artery thrombosis, and 1 hepatic artery pseudo-aneurysm) with vascular complication after liver transplantation had been studied retrospectively, including the correlative biochemistry data and angiographic signs. Results: Among the 7 patients, 6 patients had been successfully treated by interventional radiology procedure. The technical success rate was 85.56%. The renal functions of 3 patients with vena cava stenosis who had been treated by angioplasty improved satisfactorily. The survival time after this intervention of these 3 patients ranged from 10 days to 20 months. 1 patient still lived 20 months after the intervention, 2 died of other complications beside caval stenosis within one month after the intervention. The hepatic function of the 4 patients with hepatic artery complications treated by interventional procedures had not been redressed. Conclusion: Angiography played an important role in diagnosing the hepatic vascular complication after liver transplantation. The result of interventional radiology treatment of vena cava stenosis was encouraging

  6. Procedural sedation analgesia

    Directory of Open Access Journals (Sweden)

    Sheta Saad

    2010-01-01

    Full Text Available The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA. The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy.

  7. Intervention of the army health service in the case of radiological accident in peace time

    International Nuclear Information System (INIS)

    Curet, P.M.; Croq, M.

    2001-01-01

    The Army Health Service has conceived an organisation and has at its disposal the means necessary to answer the consequences of an accident having a radiological type in peace time in the military field. Its intervention area can be extended to the civil medium at the public authorities demand to give assistance. (N.C.)

  8. Radiological protection in interventional cardiology in Chile

    International Nuclear Information System (INIS)

    Ramirez, A.; Leyton, F.A.; Farias, E.; Silva, A.M.; Vano, E.; Oyarzun, C.; Gamarra, J.; Ortiz, P.

    2001-01-01

    In September 2000, an expert mission was assigned to Chile, under the regional project named 'International BBS in Medical Practices Radiation Protection and Quality Assurance In Interventional Radiology' (ARCAL XLIX). The objective of the mission was to evaluate the level of radiation protection (RP) and safety in interventional cardiology ( IC ) installations. A team of local cardiologists, medical physicists and technologists was created for this purpose and during one week, several cardiology laboratories were evaluated and some basic quality controls (QC) were carried out. A basic pilot training course in radiation protection was imparted at the Hospital of the University of Chile in Santiago de Chile and some of the key objectives for a future national quality assurance programme were presented during the national congress of IC. In addition, a national survey on radiation protection aspects was circulated and its results evaluated. These activities enabled the local team to become familiar with the methodology of assessment of the level of protection and the organization of a programme, which was illustrated with the examples of similar European programmes. As result of these actions, several proposals were made to both the local authorities and the IAEA. The most important were: a) to initiate a basic QC programme, b) to organize a training in RP for cardiologists in order to formalize their accreditation, c) to improve personal occupational dosimetry, d) to initiate a programme of patient dosimetry, e) to optimize the technical and clinical protocols, f) to create a national registry of incidents with skin injuries. (author)

  9. Contributions to the genetic and mean bone-marrow doses of the Australian population from radiological procedures

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1980-06-01

    The results of a national survey of radiological procedures used for diagnosis and therapy in medicine, dentistry and chiropracty are reviewed. Statistical data for the distribution and frequency of various procedures in Australian hospitals and practices are summarised, together with their associated radiation doses. Annual genetically significant and mean bone-marrow doses to the Australian population arising from these procedures are derived for the survey year of 1970. Values of 176 microgray and 651 microgray for the annual (per capita) genetic and mean bone-marrow doses respectively are reported. These compare closely with corresponding estimates in other countries with similar medical practices to those in Australia

  10. Dose estimation of interventional cardiologists in different body regions

    International Nuclear Information System (INIS)

    Borba, Iana Q. de; Luz, Renata M. da; Capaverde, Alexandre S.; Silva, Ana M. Marques da; Caramori, Paulo Ricardo Avancini

    2015-01-01

    Interventional radiology is one of the medical specialties that provides the highest doses to professionals, widely used in cardiology, being called interventional cardiology. In order to contribute to the optimization of occupational radiation protection in interventional cardiology procedures, the aim of this study is to evaluate the dose estimation received in different body regions by physicians in interventional cardiology procedures. Two physicians were followed, named as A and B, during one month period, performing a total of 127 procedures (70 for A and 57 for B) of interventional cardiology. During the procedures, dosimeters in different body regions beyond the full-body dosimeter were positioned. The results showed the highest values for the estimated dose received by workers were in the right wrist and left side face regions, for the physician A, and in the left knee and left side face, for the physician B. Results demonstrate the importance of using individual protection equipment by physicians in interventional cardiology, including lead glasses, besides monitoring dosimeters for other body regions, such as wrist, face and knee. (author)

  11. Celiac artery stenosis/occlusion treated by interventional radiology

    International Nuclear Information System (INIS)

    Ikeda, Osamu; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki

    2009-01-01

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  12. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  13. Contemporary imaging: Magnetic resonance imaging, computed tomography, and interventional radiology

    International Nuclear Information System (INIS)

    Goldberg, H.I.; Higgins, C.; Ring, E.J.

    1985-01-01

    In addition to discussing the most recent advances in magnetic resonance imaging (MRI), computerized tomography (CT), and the vast array of interventional procedures, this book explores the appropriate clinical applications of each of these important modalities

  14. Manual of use and accounting of radioactive material and procedures of radiological protection for nuclear medicine

    International Nuclear Information System (INIS)

    Chavez, Miguel

    1997-03-01

    This manual of use and accounting of material radioactive and procedures of radiological safety tries to facilitate workings of protection of material radioactive in services of medicine nuclear, during diagnosis (examinations with x-rays, or those that are made in nuclear medicine), or during the processing of diseases, mainly of the carcinomas (x-ray)

  15. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  16. Percutaneous transgluteal drainage of pelvic abscesses in interventional radiology: A safe alternative to surgery.

    Science.gov (United States)

    Robert, B; Chivot, C; Rebibo, L; Sabbagh, C; Regimbeau, J-M; Yzet, T

    2016-02-01

    Interventional radiology plays an important role in the management of deep pelvic abscesses. Percutaneous drainage is currently considered as the first-line alternative to surgery. A transgluteal computed tomography (CT)-guided approach allows to access to deep infected collections avoiding many anatomical obstacles (vessels, nerves, bowel, bladder). The objective of this study was to assess the safety and efficacy of a transgluteal approach by reviewing our clinical experience. We reviewed medical records of patients having undergone percutaneous CT-guided transgluteal drainage for deep pelvic abscesses. We focused on the duration of catheter drainage, the complications related to the procedures and the rate of complete resolution. Between 2005 and 2013, 39patients (27women and 12men; mean age: 52.5) underwent transgluteal approach CT-guided percutaneous drainage of pelvis abscesses in our department. The origins of abscesses were postoperative complications in 34patients (87.2%) and infectious intra-abdominal disease in 5patients (12.8%). The mean duration of drainage was 8.3days (range: 3-33). Laboratory cultures were positive in 35patients (89.7%) and Escherichia coli was present in 71.4% of the positive samples. No major complication was observed. Drainage was successful in 38patients (97.4%). A transpiriformis approach was more significantly associated with intra-procedural pain (P=0.003). Percutaneous CT-guided drainage with a transgluteal approach is a safe, well-tolerated and effective alternative to surgery for deep pelvic abscesses. This approach should be considered as the first-line intention for the treatment of deep pelvic abscesses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Interventional radiology in benign diseases of the biliary tract

    International Nuclear Information System (INIS)

    Juliani, G.; Gandini, G.

    1986-01-01

    Most references in the literature on interventional radiology of the biliary tract refer to the treatment of cancer; only occasionally are benign conditions mentioned. An updated list of radiosurgical instruments on the market in Italy is presented. The operating technique from the preparation of the patient to the performance of percutaneous transhepatic cholangiography (PTC), biliary drainage, transhepatic bilioplasty, percutaneous extraction and chemical cholelitholisis of biliary calculi and drainage of biliary collections is then described. A personal series is then presented. It consist of 93 patients in whom one or more of the following conditions were diagnosed: exclusively intrahepatic calculosis (3 cases), calculosis of the common bile duct (23 percutaneous treatments), empyema of the gallbladder (6 cases), suppurating cholangitis (46 cases), sclerotic or inflammatory stenosis (16 cases), biliary collections (14 cases). Results are reported and commented on

  18. Radiology Physician Extenders: A Literature Review of the History and Current Roles of Physician Extenders in Medical Imaging.

    Science.gov (United States)

    Sanders, Vicki L; Flanagan, Jennifer

    2015-01-01

    The purpose of the literature review was to assess the origins of radiology physician extenders and examine the current roles found in the literature of advanced practice physician extenders within medical imaging. Twenty-six articles relating to physician assistants (PAs), nurse practitioners (NPs), radiologist assistants (RAs), and nuclear medicine advanced associates (NMAAs) were reviewed to discern similarities and differences in history, scope of practice, and roles in the medical imaging field. The literature showed PAs and NPs are working mostly in interventional radiology. PAs, NPs, and RAs perform similar tasks in radiology, including history and physicals, evaluation and management, preprocedure work-up, obtaining informed consent, initial observations/reports, and post-procedure follow-up. NPs and PAs perform a variety of procedures but most commonly vascular access, paracentesis, and thoracentesis. RAs perform gastrointestinal, genitourinary, nonvascular invasive fluoroscopy procedures, and vascular access procedures. The review revealed NMAAs are working in an advanced role, but no specific performances of procedures was found in the literature, only suggested tasks and clinical competencies. PAs, NPs, and RAs are currently the three main midlevel providers used in medical imaging. These midlevel providers are being used in a variety of ways to increase the efficiency of the radiologist and provide diagnostic and therapeutic radiologic procedures to patients. NMAAs are being used in medical imaging but little literature is available on current roles in clinical practice. More research is needed to assess the exact procedures and duties being performed by these medical imaging physician extenders.

  19. Improving child protection: a systematic review of training and procedural interventions.

    Science.gov (United States)

    Carter, Y H; Bannon, M J; Limbert, C; Docherty, A; Barlow, J

    2006-09-01

    To synthesise published evidence regarding the effectiveness of training and procedural interventions aimed at improving the identification and management of child abuse and neglect by health professionals. Systematic review for the period 1994 to 2005 of studies that evaluated child protection training and procedural interventions. Main outcome measures were learning achievement, attitudinal change, and clinical behaviour. Seven papers that examined the effectiveness of procedural interventions and 15 papers that evaluated training programmes met the inclusion criteria. Critical appraisal showed that evaluation of interventions was on the whole poor. It was found that certain procedural interventions (such as the use of checklists and structured forms) can result in improved recording of important clinical information and may also alert clinical staff to the possibility of abuse. While a variety of innovative training programmes were identified, there was an absence of rigorous evaluation of their impact. However a small number of one-group pre- and post-studies suggest improvements in a range of attitudes necessary for successful engagement in the child protection process. Current evidence supports the use of procedural changes that improve the documentation of suspected child maltreatment and that enhance professional awareness. The lack of an evidence based approach to the implementation of child protection training may restrict the ability of all health professionals to fulfil their role in the child protection process. Formal evaluation of a variety of models for the delivery of this training is urgently needed with subsequent dissemination of results that highlight those found to be most effective.

  20. Non-traumatic abdominal emergencies: imaging and intervention in acute pancreatic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, Carlo; Mansueto, Giancarlo; D' Onofrio, Mirko; Gasparini, Anna; Ferrara, Rosa Maria [Department of Radiology, University Hospital ' ' G.B. Rossi' ' , Piazza L.A. Scuro 10, 37134 Verona (Italy); Falconi, Massimo [Department of Surgery, University Hospital ' ' G.B. Rossi' ' , Piazza L.A. Scuro 10, 37134 Verona (Italy)

    2002-10-01

    Pancreatic emergency, unrelated to traumatic events, can occur as a consequence of the more significant pancreatic pathologies (acute and chronic pancreatitis, tumors) or of the interventional or surgical treatment carried out as therapy for the above-mentioned lesions. Acute pancreatic conditions are represented by pancreatic infections, the involvement of organs, structures, and adjacent spaces within the pancreatic disease, and, lastly, vascular complications. Acute pancreatic conditions are common in pancreatic diseases and can be catastrophic; even if there is a gamut in the severity of clinical presentation, each can be potentially life threatening. Immediate radiological detection of the lesions together with a correct therapeutic percutaneous radiological approach whenever an interventional procedure is preferable to surgery or, when performed before surgery, whenever it can optimize its results, is of fundamental importance in the management of these patients. This article focuses on the essential role of radiology and the integration of imaging and intervention in acute pancreatic conditions. (orig.)

  1. Non-traumatic abdominal emergencies: imaging and intervention in acute pancreatic conditions

    International Nuclear Information System (INIS)

    Procacci, Carlo; Mansueto, Giancarlo; D'Onofrio, Mirko; Gasparini, Anna; Ferrara, Rosa Maria; Falconi, Massimo

    2002-01-01

    Pancreatic emergency, unrelated to traumatic events, can occur as a consequence of the more significant pancreatic pathologies (acute and chronic pancreatitis, tumors) or of the interventional or surgical treatment carried out as therapy for the above-mentioned lesions. Acute pancreatic conditions are represented by pancreatic infections, the involvement of organs, structures, and adjacent spaces within the pancreatic disease, and, lastly, vascular complications. Acute pancreatic conditions are common in pancreatic diseases and can be catastrophic; even if there is a gamut in the severity of clinical presentation, each can be potentially life threatening. Immediate radiological detection of the lesions together with a correct therapeutic percutaneous radiological approach whenever an interventional procedure is preferable to surgery or, when performed before surgery, whenever it can optimize its results, is of fundamental importance in the management of these patients. This article focuses on the essential role of radiology and the integration of imaging and intervention in acute pancreatic conditions. (orig.)

  2. M2IRAGE: Management of measurements during radiological interventions geographically assisted in the environment

    International Nuclear Information System (INIS)

    Gerphagnon, O.; Roche, H.; Lelache, H.; Guelin, M.; Fauquant, J.M.; Kacenelen, Y.; Armand, Y.

    2010-01-01

    This report presents the M 2 IRAGE software, a data processing tool designed to share radioactivity measurements and to give a schematised view of a radiological situation and of its evolution, while respecting different legal frameworks, notably the obligation to produce a radiological measurement programme. After a simplified recall of the crisis management organisation, the authors describe the M 2 IRAGE software and hardware architecture, the functions of its main modules (presentation of radioprotection information during field intervention, field mission management, data browsing, and data transmission to field teams). While giving some display examples, the authors describe how an event is managed and processed by this tool: event creation, measurement acquisition, aid to decision, team management. They report and discuss the results of a national exercise which took place in September 2009 in Saclay with a prototype version of M 2 IRAGE

  3. Effect of changes in technical parameters in radiological safety

    International Nuclear Information System (INIS)

    Avendano, Ge; Fernandez, C

    2007-01-01

    This work analyzes the generation of secondary radiation that affects the professionals of health during interventional X ray procedures in first level hospitals. The research objectives were, on the one hand, to quantify the amount of radiation and to compare it with norms in force with respect to magnitudes, and on the other hand to evaluate the elements of protection used. The measurements will help to improve the radiological safety, to assess the eventuality of risks and, in the last term, to the possibility of norms modification for the improvement of the protection, especially that of the personnel who daily make a certain amount of interventional procedures guided by radiation, like angiographic cine applications, using continuous or pulsed fluoroscopy. The motivation of the study is in the suspicion that present interventionism is made with a false sensation of safety, based only in the use of lead apron and protection elements incorporated in the equipment by the manufacturer, nevertheless not always the health personnel are conscious that an excessive proximity with the tube and the patient body becomes a risky source of secondary and scattered radiation. The obtained results allow us to demonstrate the existence of conditions of risk, even possible iatrogenic events, in particular when the procedures imply the use of certain techniques of radiographic exploration, thus reaching the conclusion that the radiographic methodology must be changed in order to rationalize so much?. In order to achieve this we propose modifications to the present norms and legislation referred to the radiological safety in Chile

  4. Sedoanalgesia in interventional radiology; Analgosedierung in der interventionellen Radiologie

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Pfeifer, K.J.; Reiser, M. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Klinische Radiologie; Wagner, P. [Klinikum der Universitaet Muenchen, Muenchen (Germany). Inst. fuer Anaesthesiologie und Intensivmedizin; Ambulantes Operationszentrum, Muenchen Pasing (Germany)

    2002-02-01

    Purpose: Development of a save and effective protocol for analgosedation of patients undergoing painful interventional procedures. Material and Methods: In a prospective trial a consecutive series of 72 adult patients underwent analgosedation during painful interventions. A radiologist performed the analgosedation, the patients received a combination of a shortly effective piperidine derivative (Alfentanil [Rapifen {sup trademark} ]; 7.5-15 {mu}g/kg body weight) and Benzodiazepine (midazolam [Dormicum {sup trademark} ]; 20 {mu}g/kg body weight). After pre-procedure oxygenation patients were continuously monitored. Pain and discomfort were scored using an established visual-analog pain score (0-10). A control group (n=24) had received midazolam, pentazocine or fentanyl according to the study protocol. Results: All procedures could be carried out by an interventional radiologist and a nurse and/or technologist only. In 69/72 cases adequate analgosedation could be achieved. Injection of alfentanil was titrated, with a rapid onset and short acting effect of the analgesia. Patients reported an average pain score of 2.6 vs. 4.5 in the control group. Over 55% experienced no or mild pain (score 0-3), in the control group only 8% reached this level. Conclusion: A combination of shortly effective alfentanil and midazolam allows interventional radiologists to perform major procedures alone under effective analgosedation. This medication scheme is superior to the medication upon demand. (orig.) [German] Ziel: Die Entwicklung eines einfach zu handhabenden Protokolls fuer Radiologen zur Analgosedierung bei schmerzhaften interventionellen Eingriffen. Methoden: Prospektiv wurden 72 konsekutive Patienten zusammengefasst, bei denen schmerzhafte interventionelle Eingriffe geplant waren. Die Anlagosedierung erfolgte mit einer Kombinationsmedikation aus kurzwirksamem Piperidinderivat (Alfentanil [Rapifen {sup trademark} ]; 7,5-15 {mu}g/kg KG) und Benzodiazepin (Midazolam [Dormicum {sup

  5. Interventional radiology in pain treatment

    International Nuclear Information System (INIS)

    Kastler, B.

    2007-01-01

    Disease whether it is acute, chronic, or at end stage, is all too regularly accompanied by pain. Pain is often difficult to control, in malignant disease in particular, even by using appropriate medications. Anesthesiologists and pain therapists have developed new invasive therapies including nerve block, sympatholysis, and neurolysis useful for both diagnosis and pain management. To insure the efficiency and safety of these procedures, and furthermore for elaborate techniques such as vertebroplasty, cementoplasty, and radio frequency bone ablation, imaging guidance becomes mandatory. This state-of-the-art book describes the techniques elaborated by interventional radiologists in the treatment and palliation of a variety of benign and malignant painful conditions. Each chapter written by an expert in the field concentrates on a particular aspect of pain management, with emphasis on practical issues. This book will serve as an invaluable source of information for the radiologist willing to learn about new pain therapy techniques aimed at optimizing or replacing more invasive traditional methods. (orig.)

  6. Radiology. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Reiser, Maximilian; Kuhn, Fritz-Peter; Debus, Juergen

    2011-01-01

    The text book on radiology covers the following issues: Part A: General radiology: Fundamental physics: radiation biology; radiation protection fundamentals: radiologic methods; radiotherapy; nuclear medicine. Part B: Special radiology: Thorax; heart; urogenital tract and retroperitoneum; vascular system and interventional radiology; esophagus, stomach, small and large intestines; liver, biliary system, pancreas and spleen; mammary glands; central nervous system; spinal cord and spinal canal; basis of the skull, facial bones and eye socket; neck; pediatric imaging diagnostics.

  7. Radioprotection of patients and workers in interventional and operating block radiology

    International Nuclear Information System (INIS)

    Menechal, P.; Valero, M.; Megnigbeto, C.; Marchal, C.; Godet, J.L.

    2011-01-01

    Over the last ten years or so, extensive development in radiological and implantable equipment has generated significant growth in radio-guided procedures. The real benefit of these practices to patients explains their development. These procedures can be undertaken using not only dedicated, specific fixed installations and computed tomography scanners, but also mobile installations in facilities not designed for radiography, such as operating blocks. The complexity of these procedures and the times spent implementing the required radiation can lead to major detrimental effects on personnel and patients, if they are not fully controlled. Many specialist medical disciplines now perform invasive procedures guided by images. Optimisation of patient doses mainly depends on the training level of medical teams, the intrinsic performance characteristics of the equipment used, adjustment of the technical parameters and the presence or absence of qualified personnel. Optimisation of professional personnel exposure is complex and depends on the performance conditions of procedures, which can expose workers extensively and non-uniformly. Designation of personnel competent in radioprotection, assessment of risks and definition of controlled areas, analysis of workstations and dosimetric monitoring of operators (especially of body extremities) are difficult to implement. Use of collective and personal protective equipment must be improved. The general manager of the French nuclear safety authority (ASN) has referred the matter to the permanent group of radioprotection experts (GPMED) to ensure that recommendations are drawn up in the short term. (authors)

  8. Recommendations to improve radiation safety during invasive cardiovascular procedures

    International Nuclear Information System (INIS)

    Miranda, Patricia; Ubeda, Carlos; Vano, Eliseo; Nocetti, Diego

    2014-01-01

    In this paper we present guidelines aimed to improve radiation safety during invasive cardiovascular procedures. Unwanted effects upon patients and medical personnel are conventionally classified. A program of Quality Assurance is proposed, an aspect of which is a program for radiologic protection, including operator protection, radiation monitoring, shielding and personnel training. Permanent and specific actions should be taken at every cardiovascular lab, before, during and after interventions. In order to implement these guidelines and actions, a fundamental step is a review of current legislation. Specific programs for quality control and radiologic protection along with a definition of acceptable radiation exposure doses are required

  9. Shielding Effect of Lead Glasses on Radiologists' Eye Lens Exposure in Interventional Procedures.

    Science.gov (United States)

    Hu, Panpan; Kong, Yan; Chen, Bo; Liu, Qianqian; Zhuo, Weihai; Liu, Haikuan

    2017-04-20

    To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Coefficients calculations of conversion of cancer risk for occupational exposure using Monte Carlo simulations in cardiac procedures of interventionist radiology

    International Nuclear Information System (INIS)

    Santos, William S.; Neves, Lucio P.; Perini, Ana P.; Caldas, Linda V.E.; Maia, Ana F.

    2014-01-01

    Cardiac procedures are among the most common procedures in interventional radiology (IR), and can lead to high medical and occupational exposures, as in most cases are procedures complex and long lasting. In this work, conversion coefficients (CC) for the risk of cancer, normalized by kerma area product (KAP) to the patient, cardiologist and nurse were calculated using Monte Carlo simulation. The patient and the cardiologist were represented by anthropomorphic simulators MESH, and the nurse by anthropomorphic phantom FASH. Simulators were incorporated into the code of Monte Carlo MCNPX. Two scenarios were created: in the first (1), lead curtain and protective equipment suspended were not included, and in the second (2) these devices were inserted. The radiographic parameters employed in Monte Carlo simulations were: tube voltage of 60 kVp and 120 kVp; filtration of the beam and 3,5 mmAl beam area of 10 x 10 cm 2 . The average values of CCs to eight projections (in 10 -4 / Gy.cm 2 were 1,2 for the patient, 2,6E-03 (scenario 1) and 4,9E-04 (scenario 2) for cardiologist and 5,2E-04 (scenario 1) and 4,0E-04 (Scenario 2) to the nurse. The results show a significant reduction in CCs for professionals, when the lead curtain and protective equipment suspended are employed. The evaluation method used in this work can provide important information on the risk of cancer patient and professional, and thus improve the protection of workers in cardiac procedures of RI

  11. Comparison between a digital scanning system and a conventional screen film system in the full spine radiological procedure in pediatrics

    International Nuclear Information System (INIS)

    Espana, M. L.; Gomez, G.; Romero, A.; Minambres, A.; Albi, G.; Floriano, A.; Rodirguez, A.; Lopez Franco, P.

    2004-01-01

    To compare from both dosimetry and image quality standpoints, a digital scanning system with a conventional screen film system, in the full spine radiological procedure. The standard patient is considered to be 12 years old, and a sample of forty patients referred for full spine radiological procedure has been studied. Gonad shielding has been used in all the patients, and its efficiency has been evaluated. Dosimetric study includes Kerma-area product, and thorax and gonad entrance surface dose. Kerma area product has been measured using a transmission camera, and for entrance surface dose estimation both thermoluminescent dosemeter LiF: Mg, Cu, P and LiF: Mg, Ti have been utilized. Three radiologists have evaluated the image quality according to the degree of fulfilment of the image quality criteria. (Author) 22 refs

  12. Radiation-Induced Noncancer Risks in Interventional Cardiology: Optimisation of Procedures and Staff and Patient Dose Reduction

    Science.gov (United States)

    Khairuddin Md Yusof, Ahmad

    2013-01-01

    Concerns about ionizing radiation during interventional cardiology have been increased in recent years as a result of rapid growth in interventional procedure volumes and the high radiation doses associated with some procedures. Noncancer radiation risks to cardiologists and medical staff in terms of radiation-induced cataracts and skin injuries for patients appear clear potential consequences of interventional cardiology procedures, while radiation-induced potential risk of developing cardiovascular effects remains less clear. This paper provides an overview of the evidence-based reviews of concerns about noncancer risks of radiation exposure in interventional cardiology. Strategies commonly undertaken to reduce radiation doses to both medical staff and patients during interventional cardiology procedures are discussed; optimisation of interventional cardiology procedures is highlighted. PMID:24027768

  13. Differential kinetics of response and toxicity using stereotactic radiation and interventional radiological coiling for pulmonary arterio-venous shunting from metastatic leiomyosarcoma

    International Nuclear Information System (INIS)

    Wong, Annie Ngai Man; Siva, Shankar; Chin, Kwang; Manser, Renee; Antippa, Phillip; Dowling, Richard; Mileshkin, Linda Rose

    2015-01-01

    Case report demonstrating the differential kinetics of response and toxicity using stereotactic radiation and interventional radiological coiling for pulmonary arterio-venous shunting from leiomyosarcoma pulmonary metastases.

  14. Periprocedural Prophylactic Antithrombotic Strategies in Interventional Radiology: Current Practice in the Netherlands and Comparison with the United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Wiersema, Arno M., E-mail: arno@wiersema.nu [Westfriesgasthuis, Hoorn, Department of Surgery (Netherlands); Vos, Jan-Albert, E-mail: j.a.vos@antonius.net [St Antonius Hospital, Nieuwegein, Department of Radiology, Division of Interventional Radiology (Netherlands); Bruijninckx, Cornelis M. A., E-mail: cmabruijninckx@planet.nl [Equipe Zorg Bedrijven, Rotterdam, Department of Surgery (Netherlands); Delden, Otto M. van, E-mail: o.m.vandelden@amc.uva.nl [Academic Medical Centre, University of Amsterdam, Department of Radiology, Division of Interventional Radiology (Netherlands); Reijnen, Michel M. P. J., E-mail: mmpj.reijnen@gmail.com [Rijnstate Hospital, Arnhem, Department of Surgery (Netherlands); Vahl, Anco, E-mail: a.c.vahl@olvg.nl [Onze Lieve Vrouwe Gasthuis, Amsterdam, Department of Surgery (Netherlands); Zeebregts, Clark J., E-mail: czeebregts@hotmail.com [University of Groningen, Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen (Netherlands); Moll, Frans L., E-mail: F.L.Moll@umcutrecht.nl [University of Utrecht, Department of Surgery, Division of Vascular Surgery, University Medical Centre Utrecht (Netherlands)

    2013-12-15

    Purpose: The use of prophylactic antithrombotic drugs to prevent arterial thrombosis during the periprocedural period during (percutaneous) peripheral arterial interventions (PAIs) is still a matter of dispute, and clear evidence-based guidelines are lacking. To create those guidelines, a study group was formed in the Netherlands in cooperation with the Dutch Society of Vascular Surgery and the Society of Interventional Radiology. The study group is called 'Consensus on Arterial PeriProcedural Anticoagulation (CAPPA).' Materials and Methods: The CAPPA study group devised and distributed a comprehensive questionnaire amongst Dutch interventional radiologists (IRs). Results: One hundred forty-two IRs responded (68 %) to the questionnaire. Almost no IR stopped acetyl salicylic acid before interventions, and 40 % stopped clopidogrel before PAI but not before carotid artery stenting (CAS). A flushing solution on the sideport of the sheath was used routinely by 30 % of IRs in PAI and by 50 % of IRs during CAS. A minority of IRs used a heparinised flushing solution (28 %). Unfractionated heparin was used by 95 % of IRs as bolus; 5000 IU was the most used dosage. Timing of administration varied widely. A majority of IRs (75 %) repeated heparin administration after 1 h. Conclusion: A substantial variety exists amongst IRs in the Netherlands regarding the use of prophylactic periprocedural antithrombotic drugs to prevent arterial thrombosis during PAI. When compared with varying results regarding the use of heparin in the United Kingdom, the variety in the Netherlands showed a different pattern. The proven variety in these countries, and also between these countries, emphasises the need for authoritative studies to develop evidence-based practical guidelines.

  15. The role of the interventional radiologist in enteral alimentation.

    Science.gov (United States)

    Given, M F; Lyon, S M; Lee, M J

    2004-01-01

    The provision of enteral nutrition through the placement of gastrostomy/gastrojejunostomy tubes is a well-established procedure. Traditionally, these catheters have been placed either surgically or endoscopically; however, over the past two decades interventional radiologists have increasingly performed these procedures successfully. The perceived advantages of this route lie in the reported lower morbidity and mortality rates. In addition, percutaneous radiologically guided (PRG) catheters may be placed in certain subgroups of patients in whom it would be technically difficult or impossible by other routes, e.g., patients with head and neck or oesophageal tumours. The aim of this review is to describe the techniques of radiologically placed gastrostomy/gastrojejunostomy, discuss its indications and contraindications, describe any associated potential complications and compare PRG results with the more established techniques of open surgical and endoscopic placement. We also describe some recent procedural and catheter modifications.

  16. The role of the interventional radiologist in enteral alimentation

    Energy Technology Data Exchange (ETDEWEB)

    Given, M.F.; Lyon, S.M.; Lee, M.J. [Department of Academic Radiology, Beaumont Hospital, Dublin 9 (Ireland); Royal College of Surgeons in Ireland, St. Stephen' s Green, Dublin 2 (Ireland)

    2004-01-01

    The provision of enteral nutrition through the placement of gastrostomy/gastrojejunostomy tubes is a well-established procedure. Traditionally, these catheters have been placed either surgically or endoscopically; however, over the past two decades interventional radiologists have increasingly performed these procedures successfully. The perceived advantages of this route lie in the reported lower morbidity and mortality rates. In addition, percutaneous radiologically guided (PRG) catheters may be placed in certain subgroups of patients in whom it would be technically difficult or impossible by other routes, e.g., patients with head and neck or oesophageal tumours. The aim of this review is to describe the techniques of radiologically placed gastrostomy/gastrojejunostomy, discuss its indications and contraindications, describe any associated potential complications and compare PRG results with the more established techniques of open surgical and endoscopic placement. We also describe some recent procedural and catheter modifications. (orig.)

  17. SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A [UT MD Anderson Cancer Center, Houston, TX (United States); Pasciak, A [University of Tennessee Medical Center, Knoxville, TN (United States); Wagner, L [UT Medical School, Houston, TX (United States)

    2016-06-15

    Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

  18. Establishment of an inferior vena cava filter database and interventional radiology led follow-up - retrieval rates and patients lost to follow-up.

    Science.gov (United States)

    Klinken, Sven; Humphries, Charlotte; Ferguson, John

    2017-10-01

    To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.

  19. Interventional radiology in the diagnosis, management, and follow-up of pseudoaneurysms.

    LENUS (Irish Health Repository)

    Keeling, A N

    2009-01-01

    Arterial wall disruption, as a consequence of inflammation\\/infection, trauma (penetrating or blunt), or iatrogenic causes, may result in pseudoaneurysm formation. Currently, iatrogenic causes are increasing as a result of the growth of endovascular intervention. The frequency of other causes also seems to be increasing, but this may simply be the result of increased diagnosis by better imaging techniques, such as multidetector contrast-enhanced computed tomography. Clinically, pseudoaneurysms may be silent, may present with local or systemic signs, or can rupture with catastrophic consequences. Open surgical repair, previously the mainstay of treatment, has largely been replaced by image-guided occlusion methods. On the basis of an experience of over 100 pseudoaneurysms, treatments at various anatomical sites, imaging modalities used for accurate diagnosis, current changing therapeutic options for pseudoaneurysm management, approved embolization agents, and clinical follow-up requirements to ensure adequate treatment will be discussed. Image-guided direct percutaneous and endovascular embolization of pseudoaneurysms are established treatment options with favorable success rates and minimal morbidity. The pendulum has now swung from invasive surgical repair of pseudoaneurysms to that of image-guided interventional radiology.

  20. Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Koukorava, C.; Carinou, E.; Ferrari, P.; Krim, S.; Struelens, L.

    2011-01-01

    Measurements performed within the ORAMED project helped to evaluate the dose levels to the operators’ hands, wrists, legs and eye lenses, during several types of interventional radiology (IR) and cardiology (IC) procedures, and also to determine the parameters that affect the doses. However, the study of the effect of each parameter separately, was possible only through Monte Carlo (MC) simulations, as in clinical practice many of those parameters change simultaneously. The influence of the protective equipment, the beam projections, the beam quality, the field size and the position of the operator according to the position of access of the catheter was investigated, using anthropomorphic phantoms in setups that represent realistic IR/IC procedures. The proper use of protective shields was found to be the most important way of reducing extremity and eye lens exposure during such examinations. Ceiling suspended shields can reduce the doses to the eye lenses up to 97%, but they can also reduce hand doses about 70% when placed correctly. The highest exposure to the operator is observed for left anterior oblique (LAO) and cranial projections. Additionally, for overcouch irradiations the eyes and the hands are about 6 times more exposed compared to the cases where the tube is below the operating table. For the lateral LAO projection, placing the ceiling suspended shield at the left side of the operator is twice more effective for the protection of the eyes compared to the cases where it is placed above the patient. Finally, beam collimation was found to play an important role in the reduction of the hands and wrists doses, especially when the operator is close to the irradiation field.