WorldWideScience

Sample records for radiological evaluation size

  1. Evaluation of the field size in dental diagnostic radiology system

    International Nuclear Information System (INIS)

    Andrade, P.S.; Potiens, M.P.A.

    2006-01-01

    In this work the field size of a dental X rays machine was evaluated considering the recommendation of the Brazilian Health Ministry Regulation 453 which established basic lines of radiological protection in medical and dental diagnostic radiology. The diameter of the field should not be superior to 6 cm in the localized end point, limiting the radiated area and protecting the head-neck region. The measurements were carried out in a dental X rays machine, Dabi Atlante, model Spectro 70X Seletronic. For the field size or useful beam determination, the intra-oral films were positioned on a plain surface to be exposed in four stages and two focus-film distances (FFD), 20 cm and 27.5 cm: 1) with spacer cone; 2) without spacer cone; 3) with spacer cone and film-holding device; 4) without spacer cone and film-holding device. The results show that the diameter of the field size is satisfactory only for FFD = 20 cm. When the film-holding device is used, which is recommended by the Regulation 453, item 5.8 d(ii), the diameter of the field size exceeds the maximum recommended value of 6 cm. (authors)

  2. Radiological evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-11-21

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint.

  3. Radiological evaluation of dysphagia

    International Nuclear Information System (INIS)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-01-01

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint

  4. Radiologic evaluation of colorectal cancer

    International Nuclear Information System (INIS)

    Lee, Young Joong; Kang, Hee Tae; Kim, Jong Deok; Rhee, Hak Song

    1984-01-01

    The incidence of colorectal cancer of Korea is much lower than that of Western countries, but has shown a tendency to a slight increase recently. Barium enema is the most valuable, noninvasive and inexpensive method available to evaluate the size, shape and site of colorectal cancer. The authors reviewed and radiologically classified barium enema studies of 232 cases of colorectal cancer from Aug. 1967 to July 1982 at Presbyterian Medical Center, Jeonju, Confirmed clinically, operatively and pathologically. The results were as follows; 1. The ratio of male and female was 1.3:1, and youngest was 13 year-old and the oldest 86 year-old. 2. The peak incidence occurred from 5th to 7th decades, accounting for 78% of all cases (181/232), and there was a relatively high incidence of the disease in patients below 30 years of age at 7.8% (18/232). 3. Rectum and rectosigmoid region are the most frequently involved regions (127/232:54.8%). 4. The positivity of barium enema examination was 4.0% (232/5807), and its accuracy was 96.5% (224/232). 5. The radiologic findings were classified into 4 groups, and they were annular encircling 62.9% (146/232). polypoid fungating 26.8% (62/232), infiltrating 8.6% (20/232), and primary ulcerating 1.7% (4/232) in order of frequency. 6. The linear length of the cancer ranged from 1.5 Cm to 15 Cm, and the average length was 5.5 Cm. 7. There was no statistical correlation between the length of lesion, the site, and the radiologic findings, and stages of the lesion (P:0.750-0.250). 8. The majority of colorectal cancers was adenocarcinoma (217/232:93.6%)

  5. Radiological evaluation of chondroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, T.M.; Hawkins, I.F. Jr.

    1981-04-01

    Eleven new and six recurrent chondroblastomas were studied with multiple radiological imaging methods (plain radiography, conventional tomography, computed tomography, radionuclide bone scanning, and angiography). When the plain radiographic appearance was typical, conventional tomography or computed tomography (CT) was helpful, but other studies were not. Periosteal reaction and angiographic hypervascularity were common and did not indicate cortical breakthrough. For large, aggressive, or atypical lesions, conventional tomography and CT were helpful in delineating anatomic extent, and angiography was of value in demonstrating major vessel displacement. Radionuclide bone scanning was not useful.

  6. Radiologic evaluation of the myelomeningocele patient

    International Nuclear Information System (INIS)

    Byrd, S.E.; Radkowski, M.A.; McLone, D.G.; Storrs, B.B.

    1988-01-01

    The only radiologic procedure that is useful in the newborn with a fresh myelomeningocele is US or CT of the head to evaluate ventricular size. The imaging procedures become extremely important in the evaluation of the postoperative patient with myelomeningocele. US and/or CT is used to evaluate for hydrocephalus. MR is used to evaluate the spinal axis to determine the position of the cervicomedullary kink, hydromyelia, arachnoid cyst, inclusion epidermoids, and tethering of the spinal cord. US and myelography with CT are needed in subtle cases of tethering, diastematomyelia, arachnoid cyst, and severe scoliosis

  7. Radiologic evaluation of os odontoideum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ju; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Yong Soo; Park, Hyoung Chun; Oh, Soung Hoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-10-15

    We took an analysis on the clinical and radiologic findings of os odontoideum, which had been regarded as relatively uncommon disease, on 5 patients whom we have recently experienced. Our results were as follows: 1. Os odontoideums were incidentally discovered during the radiologic evaluation of traumatised 4 cases, who had been well being. Another one case of os odontoideum was associated with multiple epiphyseal dysplasia. 2. General radiologic findings of os odontoideum were a round or oval and hypoplastic ossicle separated from the base of odontoid process by wise gap. 3. Alanto-Axial instability was developed in 5 cases of os odontoideum by flexion and extension stress view of lateral cervical spine. 4. Flexion views of lateral cervical spine showed narrowing of anteroposterior diameter of spinal canal which were available at atlantoaxial level on 5 cases of os odontoidum. 5. CT myelogram and cervical myelogram showed anteriorly compressed dural sac and deformed spinal cord by body of axis at the atlanto-axial level.

  8. Radiological anatomy - evaluation of integrative education in radiology.

    Science.gov (United States)

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Gastric Mucosal Erosions - Radiologic evaluation -

    International Nuclear Information System (INIS)

    Kim, Seung Hyup

    1985-01-01

    70 cases of gastric mucosal erosions were diagnosed by double contrast upper gastrointestinal examinations and endoscopic findings. Analyzing the radiologic findings of these 70 cases of gastric mucosal erosions, the following results were obtained. 1. Among the total 70 cases, 65 cases were typical varioliform erosions showing central depressions and surrounding mucosal elevations. Remaining 5 cases were erosions of acute phase having multiple irregular depressions without surrounding elevations. 2. The gastric antrum was involved alone or in part in all cases. Duodenal bulb was involved with gastric antrum in 4 cases. 3. The majority of the cases had multiple erosions. There were only 2 cases of single erosion. 4. In 65 cases of varioliform erosions; 1) The diameter of the surrounding elevations varied from 3 to 20 mm with the majority (47 cases) between 6 and 10 mm. 2) In general, the surrounding elevations with sharp margin on double contrast films were also clearly demonstrated on compression films but those with faint margin were not. 3) The size of the central barium collections varied from pinpoint to 10 mm with the majority under 5 mm. The shape of the central barium collections in majority of the cases were round with a few cases of linear, triangular or star-shape. 5. In 5 cases of acute phase erosions; 1) All the 5 cases were females. 2) On double contrast radiography, all the cases showed multiple irregular depressed lesions without surrounding elevations. 3) 1 case had the history of hematemesis. 4) In 1 case, there was marked radiological improvement on follow-up study of 2 months interval. 6. In 23 cases, there were coexistent diseases with gastric mucosal erosions. These were 13 cases of duodenal bulb ulcers,7 cases of benign gastric ulcers and 3 others

  10. Radiologic evaluation of pancreatic pseudocyst

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, T. H.; Kim, Y. J.; Hong, I. S.; Kim, M. S.; Sung, K. J. [Yeonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    1986-12-15

    Pancreatic pseudocyst is a collection of necrotic tissue, old blood and secretions that escaped from the pancreas damaged by pancreatitis, trauma and chronic alcoholism. There is no epithelial cell lining the cystic wall. With the advent of ultrasound and CT more accurate diagnosis can be made. Our study was carried out to analyse the radiological and clinical findings of 32 cases of pancreatic pseudocysts confirmed at Wonju College of Medicine Yonsei University from Jan. 1979 to Aug. 1986. The results are as follows: 1. Male to female ratio was 4.3:1 Incidence was the most common in 4th decades. 2. The most frequent symptom was epigastric pain (100%). 3. In a total of 32 cases, 15 cases had a underlying cause of pancreatitis, 9 cases abdominal trauma. 4. In laboratory findings, serum amylase level was elevated in 23 cases, leucocytosis in 10 cases. 5. On chest films, the lungs were mostly normal. Soft tissue mass density in 12 cases was the most common finding on abdomen films. 6. UGI series were helpful in directing attention by pancreatic pseudocysts' location and size. 7. Ultrasonogram using primary procedure for the detection of pseudocyst (23 cases) disclosed anechoic lesion in 8 cases, mixed echo lesion in 15 cases. Mixed echo patterns, in terms of internal echo patters, were echogenic spots (8 cases), septation and echogenic spots (3 cases), fluid-fluid level (3 cases), etc. 8. CT scanning is the best imaging procedure, providing detailed morphologic information about the pancreatic pseudocyst and surrounding tissue.

  11. Radiologic techniques in evaluation endocrine disorders

    International Nuclear Information System (INIS)

    Martino, C.R.; Schultz, C.L.; Butler, H.E.; Haaga, J.R.

    1988-01-01

    This paper discusses evaluation of normal and diseased endocrine organs that has been facilitated by the development of new radiologic-imaging techniques including nuclear medicine, ultrasound, computed tomography, and magnetic resonance imaging. With improvement in resolution and tissue contrast, abnormalities as small as 5 mm can now be imaged with these modalities. Endocrinologists and clinicians involved in the evaluation and diagnosis of patients with endocrine diseases can be substantially aided by a proper radiologic workup. The authors describe and illustrate various radiologic techniques that are useful for evaluating thyroid and parathyroid derangements

  12. Follow-up of hepatic and peritoneal metastases of gastrointestinal tumors (GIST) under Imatinib therapy requires different criteria of radiological evaluation (size is not everything!!!)

    International Nuclear Information System (INIS)

    Mabille, Mylene; Vanel, Daniel; Albiter, Marcela; Le Cesne, Axel; Bonvalot, Sylvie; Le Pechoux, Cecile; Terrier, Philippe; Shapeero, Lorraine G.; Dromain, Clarisse

    2009-01-01

    Purpose: To define computed tomography (CT) criteria for evaluating the response of patients with gastrointestinal stromal tumors (GIST) who are receiving Imatinib (tyrosine-kinase inhibitor therapy). Materials and methods: This prospective CT study evaluated 107 consecutive patients with advanced metastatic GIST treated with Imatinib. Results: Seventy patients had total or partial cystic-like transformation of hepatic and/or peritoneal metastases. These pseudocysts remained unchanged in size or stable in size on successive CT examinations (stable disease according to RECIST criteria). Forty-six patients developed metastases, 17 patients showed increasing parietal thickness and 29 patients with peripheral enhancing nodules. These CT changes represented local recurrence consistent with GIST resistance to Imatinib treatment. WHO or RECIST criteria did not provide a reliable evaluation of disease evolution or recurrence. Development of new enhancement of lesions (parietal thickness or nodule) was the only reliable criterion. Conclusion: The development of peripheral thickening or enhancing nodules within cystic-like metastatic lesions, even without any change in size, represented progressive GIST under Imatinib, growing in a short time and should alert the clinician for the possible need for a change in therapy

  13. Radiological evaluation of acoustic neurinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Park, Chang Yun; Choi, Byung So [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1974-04-15

    All 25 patients surgically proven acoustic neurinoma was analysed clinically, radiographically at Severance Hospital of Yonsei Univ. The patients not proved surgically in spite of clinical diagnosis of acoustic neurinoma was excluded from this study. The results are summarized as follows; The clinical findings are; 1. The incidence of tumor in female was twice more frequent than in male and the range of age was 20-50 years peak of age at onset of symptom. 2. The clinical symptoms were variable from unilateral hearing impairment or less (100%), headache (84%) to tinnitus (60%) in order of frequency. 3. The tumor growth in the left cerebellopontine angle was twice more than in the right side with the radio of 16:8. However, in one case bilateral simultaneous growth of acoustic neurinoma was noted. The radiological findings are: The best radiographic method to study the shape and size of internal acoustic canal to demonstrate erosion or destruction of petrous pyramida was considered to be straight frontal view and tomography of the skull in our series. 1. The shape of internal acoustic canal in tumors were straight (in 2 cases), bulbous (in 12 cases), and flared (in 11 cases). Particularly there was erosion or destruction of petrous bone in all of the flared cases of canal. 2. The acoustic meatal erosion was mainly suprameatal in 14 cases of 17 which was noted definite erosion radiographically. 3. The difference of height (vertical diameter) of both side of acoustic canal were follows; 6 cases among 25 was in the range of 0-2 mm measurement, remainder was more than 2 mm. Hence the variation in greater than 1 mm in between both sides of canal in same patient should be regard as abnormal as of acoustic neurinoma. 4. The carotid angiogram shows hydrocephalic pattern in 12 cases among 17. 5. In the vertebral angiogram of 8 cases, anterolateral displacement of basilar artery (in 6 caes), the upward displacement of superior cerebellar artery (in 4 cases) was common findings

  14. Radiological evaluation of acoustic neurinoma

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Park, Chang Yun; Choi, Byung So

    1974-01-01

    All 25 patients surgically proven acoustic neurinoma was analysed clinically, radiographically at Severance Hospital of Yonsei Univ. The patients not proved surgically in spite of clinical diagnosis of acoustic neurinoma was excluded from this study. The results are summarized as follows; The clinical findings are; 1. The incidence of tumor in female was twice more frequent than in male and the range of age was 20-50 years peak of age at onset of symptom. 2. The clinical symptoms were variable from unilateral hearing impairment or less (100%), headache (84%) to tinnitus (60%) in order of frequency. 3. The tumor growth in the left cerebellopontine angle was twice more than in the right side with the radio of 16:8. However, in one case bilateral simultaneous growth of acoustic neurinoma was noted. The radiological findings are: The best radiographic method to study the shape and size of internal acoustic canal to demonstrate erosion or destruction of petrous pyramida was considered to be straight frontal view and tomography of the skull in our series. 1. The shape of internal acoustic canal in tumors were straight (in 2 cases), bulbous (in 12 cases), and flared (in 11 cases). Particularly there was erosion or destruction of petrous bone in all of the flared cases of canal. 2. The acoustic meatal erosion was mainly suprameatal in 14 cases of 17 which was noted definite erosion radiographically. 3. The difference of height (vertical diameter) of both side of acoustic canal were follows; 6 cases among 25 was in the range of 0-2 mm measurement, remainder was more than 2 mm. Hence the variation in greater than 1 mm in between both sides of canal in same patient should be regard as abnormal as of acoustic neurinoma. 4. The carotid angiogram shows hydrocephalic pattern in 12 cases among 17. 5. In the vertebral angiogram of 8 cases, anterolateral displacement of basilar artery (in 6 caes), the upward displacement of superior cerebellar artery (in 4 cases) was common findings

  15. Urogenital system diseases's radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S; Mecozzi, B

    1985-01-01

    Radiological urogenital radiography reliability, can be compromised because of absence of a correct urodynamic diagnosis. It is then required that specialist radiologists know the problems concerning the urogenital system radiographies cannot be made in many cases, because of the scarcity in hospitals of idoneous urodynamic services.

  16. Radiological evaluation of familial osteopetrosis

    International Nuclear Information System (INIS)

    Moon, Moo Chang; Kang, Shin Wha; Won, Jong Jin; Rhee, Song Joo; Choi, Ki Chul

    1980-01-01

    Authors found 16 patients with benign osteopetrosis out of 62 members of 4 families and analysed these patients clinically, radiologically, hematologically and biochemically at the Department of Radiology, Jeonbug National University Hospital from October 1977 to June 1980. The results are as follows; 1. We obtained that there is evidence of familial tendency in developing osteopetrosis because of the fact that 15 patients (94%) developed in 3 families and more than 2 patients in each family. In genetical point of view we suspected dominant trait of inheritance and could rule out recessive trait because patients were found in successive generations except for one family. There were no consangulneous marriages among the parents of these patients. 2. The majority of patients were adolescent or adult above 10 years of age when the disease was diagnosed. The incidence was identical in both sex. 3. No clinical symptoms and historical abnormalities were found in 11 patients (69%) and 5 patients (31%) showed only mild symptoms. Among 5 patients with clinical symptoms 3 patients showed pathologic fractures. In all 3 patients, fractures occurred only by mild trauma and affected sites were tubular bones and they were transverse type. 4. There were no specific relationship between ABO types and Rh reactions in developing osteopetrosis and no specific findings in hematological, biochemical and routine urinalysis. 5. The only diagnostic finding in most patients were the typical and specific radiological findings

  17. Patient exposure evaluation in Romanian radiological departments

    International Nuclear Information System (INIS)

    Girjoaba, O.; Cucu, A.

    2012-01-01

    Purpose: A nation-wide evaluation of ionizing radiation exposure of the Romanian population due to the radiological examinations is performed in accordance with European Directive 97/43 EURATOM implemented in national regulations. Method: The study is applied to the collected data from radiological departments from Romanian hospitals during 2010. The radiological examinations were grouped in three categories: conventional diagnostic radiology, interventional radiology and computed tomography. The annual collective dose was determined from the reported data about the mean effective doses and the frequency for each type of radiological examination, in conformity with the national regulations. Regarding the frequency aspects, the results include the age and gender distributions. Major results: More then 6 million radiological examinations were performed in 2010, Romania having a population about of 20.3 million inhabitants. The collective effective dose for 2010 resulted from the study is 152 mSv per 1000 inhabitants. Conclusions: Medical practitioners must select the best medical imaging investigation for each clinical case taking into account the importance of keeping the patient dose as low as possible. Medical physicists should be strongly involved in the establishing of the dosimetry procedures. (author)

  18. Decision Strategy: Radiological Evaluations: Air

    Energy Technology Data Exchange (ETDEWEB)

    Sohier, A

    2000-07-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on.

  19. Decision Strategy: Radiological Evaluations: Air

    International Nuclear Information System (INIS)

    Sohier, A.

    2000-01-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on

  20. Radiological evaluation of spontaneous pneumoperitoneum

    International Nuclear Information System (INIS)

    Kim, H. S.; Kim, J. D.; Rhee, H. S.

    1982-01-01

    112 cases of spontaneous penumoperitoneum, the causes of which were confirmed by clinical and surgical procedure at Presbyterian Medical Center from January, 1977 to July, 1981 were reviewed radiologically. The results were as follows: 1. Perforation of duodenal ulcer (46/112: 41.1%), stomach ulcer (22/112: 19.6%), and stomach cancer (11/112: 9.8%) were the three most common causes of spontaneous penumoperitoneum. These were 70.5% of all causes. 2. The most common site of free gas was both subdiaphragmatic areas (46: 41.1%). Others were Rt. subdiaphragmatic only (31: 27.7%), both subdiaphragmatic with subhepatic (16: 14.3%), Rt. subdiaphragmatic with subhepatic (7: 6.2%), Rt. subdiaphragmatic only (5: 4.4%), diffuse in abdomen (4: 3.6%), and subhepatic only (3: 2.7%). So 92.0% (103/112) were located in RUQ. 3. The radiological shape of free gas was classified: crescent (52: 46.4%) of small amount; half-moon (21: 18.8%) of moderate amount; large or diffuse (39: 34.8%) of large amount.4. The age between 31 and 60 occupied 69.1% (77/112), and male was predominant (5.2 times). 5. The patient's position showing free air most frequently was erect

  1. Evaluation of radiological detriment from negative radiological examinations

    International Nuclear Information System (INIS)

    Frometa Suarez, I.; Jerez Vergueria, S.F.

    1997-01-01

    The individul doses of radiation due to diagnostic radiology are usually low, though their contribution to the collective dose is very important given the large numbers of people exposed to these. This paper presents an analysis of the number of negative radiologiacl examinations in a major Cuban Hospital, and their contribution to the collective dose, and radiation organ and tissue, effective (expressed as severe hereditary effect and the occurrence of fatal and non fatal cancers) are all evaluated. The negative findings constitute 41 % of all examinations. The total contribution of negative examinations to the collective dose is very important given the large numbers of people exposed to these. This papaer presents an analysis of the number of negative radiological examinations in major Cuban Hospital, and their contribution to the collective dose of radiation. The absorbed dose by irradiation organ and tissue, effective dose equivalent, collective dose, and radiation risk (expressed as severe herditary effect and the occureence of fatal and non fatal cancers) are all evaluated. The negative findings constitute 41% of all examinations. The total contribution of negative examinations. The total contribution of negative examinations to the collective dose are found to make up 52.9 %: 11.35 Sv-man in the studied population

  2. Radiologic evaluation of chondromalacia patellae

    International Nuclear Information System (INIS)

    Lund, F.; Nilsson, B.E

    1980-01-01

    In a series of patients in whom the patello-femoral joint has been examined by arthroscopy, in conjunction with arthrotomy or both, previously obtained films were reviewed. A series of radiologic morphometric measurements with bearing on the shape of the patella and the patello-femoral joint was carried out and compared between patients who had normal patello-femoral joints, patients with chondromalacia grade II or III and patients with chondromalacia grade IV or arthrosis. No difference between the three groups in any of the variables was found. However, a shallow excavation in the subchondral bone was observed in the lateral view of the patella in most of those patients with proven chondromalacia patellae. (Auth.)

  3. Radiologic evaluation of malignant histiocytoma

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Sun Wha; Yoon, Yup; Sung, Dong Wook; Ahn, Chi Yul

    1987-01-01

    Malignant fibrous histiocytoma is a new malignant tumor entity of histiocytic origin which arises as a primary tumor of the bone as well as the soft tissue. Radiologic features of 12 cases of pathologically proven intra-and extraosseous malignant fibrous histiocytoma were analyzed. The results were as follows : 1. Seven cases were of soft tissue origin and 5 cases were of primary bone origin. 2. Seven were male and 5 were female: Eight cases were beyond 5th decades. 3. The clinical presentations of malignant fibrous histiocytoma of the soft tissue origin were a mass with rapid growth or high rate of local recurrence. The roentgen evidence of soft tissue density mass was demonstrated in 7 cases and scintigraphic evidence of cortical invasion was suggested in 2 cases. 4. Malignant fibrous histiocytoma arising from bones had ill defined moth-eaten osteolytic lesion with cortical destruction, periosteal reaction and soft tissue extension. 5. Among 12 cases, there were 2 cases of pulmonary metastases and 2 cases of osseous metastases. 6. In the presence of soft tissue mass with locally aggressive behavior and/or nonspecific roentgen features of malignant bone tumor, one should consider the possibility of malignant fibrous histiocytoma

  4. Radiological evaluation of abdominal trauma

    International Nuclear Information System (INIS)

    Ahn, K. S.; Cho, Y. H.; Kim, O.

    1982-01-01

    Simple abdomen film has played an important role in decision of emergency operations in patients with the abdominal trauma. Nowadays, it still acts as a primary and inevitable processes in emergency condition. At the Department of Radiology, Hanil Hospital, 70 patients, who were laparotomied due to penetrating or nonpernetraing abdominal trauma, were observed and analyzed with simple abdomen film after comparison with the operative findings. The results are as follows: 1. Most frequent age distribution was 10 to 39 years and marked 70%. Male was in 90% incidence. 2. Penetrating injury largely involved the small bowel and abdominal wall. Non-penetrating injury usually involved the spleen, small bowel, liver, kidney, pancreas, duodenum. 3. Single organ injury occurred in higher incidence at the small bowel and abdominal wall. Multiple organ injury occurred in higher incidence at the spleen, liver, kidney and pancreas. 4. Organ distribution was 26% in spleen, 22% in small bowel, 14% in liver, 11% in abdominal wall. 7% in pancreas, 7% in kidney. 5% in duodenum, 4% in GB and CBD, 2% in diaphragm, 2% in colon, and 1% in stomach. 5. The specific roentgen findings and their frequency which useful in differential diagnosis at abdominal trauma, were as follows: a) flank fluid; Detectable possibility was 71% in liver laceration, 69% in spleen laceration and 57% in pancreas laceration. b) ipsilateral psoas shadow obliteration; Detectable possibility was 57% in liver laceration, 57% in kidney laceration and 46% in spleen laceration. c) free air; Detactable possibility was 60% in duodenal perforation, and 36% in peroration of upper part of small bowel. d) Reflex ileus; Detectable possibility was 64% in small bowel, 50% in liver laceration and 35% in spleen laceration. e) rib fracture; Detactable possibility was 36% in liver laceration and 23% in spleen laceration. f) pleural effusion; Detectable possibility was 29% in liver laceration and 27% in spleen laceration

  5. Radiological evaluation of failed total hip replacement

    International Nuclear Information System (INIS)

    Raspa, V.; Aldrovandi, S.; Pompei, G.

    1988-01-01

    The retrospective study of 50 operated cases of cemented total hip replacement and a review of the literature enabled the authors to define the radiological features of the above-mentioned condition. These features include one or more of the following signs: calcar reabsorption, lacunar erosions, modified relatioships between the prosthesis components, sepsis and loosening, periarticular calcifications dislocation and fracture of prosthesis components. Careful evaluation of these radiological features is extremely important for both an early diagnosis of failed total hip replacement and the choice of an adequate surgical treatment

  6. Efficacy of radiology of the esophagus for evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.

    1981-05-15

    The efficacy of radiology in evaluating dysphagia was studied in 86 patients by comparison to endoscopic findings. In the 66 patients with endoscopic abnormalities radiology was correct in 54, for a sensitivity of 82%. Sensitivity of radiology improved to 95% if mild esophagitis was excluded. In the 20 patients with normal endoscopy, radiology was normal in 18 (90%). Thus radiology proved to be a reliable means of evaluating the esophagus in patients with dysphagia.

  7. Diabetic muscle infarction: radiologic evaluation

    International Nuclear Information System (INIS)

    Chason, D.P.; Fleckenstein, J.L.; Burns, D.K.; Rojas, G.

    1996-01-01

    Four patients with severe diabetes mellitus presenting with acute thigh pain, tenderness, and swelling were evaluated by imaging techniques and biopsy. Edema in the affected muscles was seen in two patients with MRI studies. Femoral artery calcification and mild muscle swelling was present in one patient who underwent CT. Decreased echogenicity was seen in the involved muscle in a patient studied with ultrasound. Serum enzymes were normal or mildly elevated in three patients (not reported in one). Biopsy demonstrated necrosis and regenerative change in all cases. MRI, although nonspecific, is the best imaging technique to suggest the diagnosis of DMI in the appropriate clinical setting, thereby obviating biopsy. (orig./MG)

  8. Reference doses and patient size in paediatric radiology

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.; Shrimpton, P.

    2000-01-01

    There is a wide range in patient size from a newborn baby to a 15 year old adolescent. Reference doses for paediatric radiology can sensibly be established only for specific sizes of children. Here five standard sizes have been chosen, representing 0 (newborn), 1, 5, 10 and 15 year old patients. This selection of standard ages has the advantage of matching the paediatric mathematical phantoms which are often used in Monte Carlo organ dose calculations. A method has been developed for calculating factors for normalising doses measured on individual children to those for the nearest standard-sized 'child'. These normalisation factors for entrance surface dose (ESD) and dose-area product (DAP) measurements depend on the thickness of the real child, the thickness of the nearest standard 'child', and an effective linear attenuation coefficient (μ) which is itself a function of the x-ray spectrum, the field size, and whether or not an antiscatter grid is used. Entrance and exit dose measurements were made with phantom material representing soft tissue to establish μ values for abdominal and head examinations, and with phantom material representing lung for chest examinations. These measurements of μ were confirmed and extended to other x-ray spectra and field sizes by Monte Carlo calculations. The normalisation factors are tabulated for ESD measurements for specific radiographic projections through the head and trunk, and for DAP measurements for complete multiprojection examinations in the trunk. The normalisation factors were applied to European survey data for entrance surface dose and dose-area product measurements to derive provisional reference doses for common radiographic projections and for micturating cystourethrography (MCU) examinations - the most frequent fluoroscopic examination on children. (author)

  9. Radiologic evaluation of wrist arthrography

    International Nuclear Information System (INIS)

    Park, Yang Hee; Seong, Hyeun Lim; Yang, Jae Beom; Park, Chan Sup; Lee, Sang Seun

    1991-01-01

    Wrist arthrography allows direct visualization of the cartilage and synovial structure not seen in plain film. Arthrography of the wrist is valuable in evaluating patients with persistent wrist pain and limitation of motion after trauma. Wrist arthrography was performed in the evaluation of 30 patients with rheumatoid arthritis (2 cases), ganglions (12 cases), and wrist trauma (16 cases), and contrast media was injected in radiocarpal joint. The arthrographic findings were analyzed, and the results were as follows: In 16 patients with wrist trauma, 12 cases (75%) of compartment communication was seen including communication with distal radioulnar joint (44%), midcarpal joint (69%), and common carpometacarpal joint (63%). Of the total 30 patients, the pisiform-triquetral joint communicated with the radio carpal joint in 9 cases (30%). In 16 patients with trauma, the findings of post-traumatic arthritis included tendon communication (50%), irregular synovium (31%), and rupture of the joint capsule (25%). There was no lymphatic filling. Of 3 scaphoid fracture patients without bony callus formation, fibrous union was verified in one patient and nouncion in 2. O 12 patients with ganglion, communication between the ganglion and radiocarpal joint was seen in 2 cases and no communication in 10 cases

  10. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    International Nuclear Information System (INIS)

    Triantopoulou, Charikleia; Papaparaskeva, Kleo; Agalianos, Christos; Dervenis, Christos

    2016-01-01

    •The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging.•Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation.•Correlation may explain any discrepancies between radiological and histopathological findings.•Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging. Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation. Correlation may explain any discrepancies between radiological and histopathological findings. Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts). The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm). This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation), the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins

  11. Radiological evaluation of myositis ossificans

    International Nuclear Information System (INIS)

    Kwon, Yang Sook; Kim, Soo Han; Lim, Young Chae; Shin, Hyun Ja

    1986-01-01

    The 35 patients who have suffered from myositis ossificans were investigate for 11 years. They were post traumatic patients. They trauma was divided into 3 groups; spinal cord injury, direct injury (fracture) and mixed type involving both. We evaluated the age distribution, the frequency of myositis ossificans, predilection site, bilaterally and relation between predilection site and bilaterally to the type of trauma. The results are as follows; 1. The age distribution was highest in 4th decades (12 among 35 patients). 2. In regard to distribution of 35 patients, spinal cord injury were most common (15 cases, 43%), the fracture nextly common (14, 40%) and then mixed type (6, 17%). 3. Among 51 cases of myositis ossificans, the frequency was highest in spinal cord injury (25 cases, 49%), next was fracture (14, 27%). 4. The predilection site of myositis ossificans were thigh (18 cases, 35%), hip (17, 33%) and buttock (6, 12%). 5. In correlation between predilection site of myositis ossificans and level of spinal cord injury, hip is the most frequent site in thoracic injury. 6. The bilaterally of myositis ossificans is 39% (20 among 51 lesions).

  12. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi; Oudkerk, Matthijs; van Ooijen, Peter

    2015-01-01

    Objective To evaluate the usability of a radiology workstation after deployment in a hospital. Significance In radiology, it is difficult to perform valid pre-deployment usability evaluations due to the heterogeneity of the user group, the complexity of the radiological workflow, and the complexity

  13. Evaluating the radiological health compliance of some beach ...

    African Journals Online (AJOL)

    Journal of Applied Sciences and Environmental Management ... Evaluating the radiological health compliance of some beach environments in Delta State ... as well as specified members of the public (customers) are not at radiological risk.

  14. Services of radiological protection: as sizing the human and material resources

    International Nuclear Information System (INIS)

    Rueda Guerrero, M. D.; Sierra Perler, I.; Lorenzo Perez, P.

    2014-01-01

    Discussion of radiological protection in the Middle Health has formed a task force to develop a technical document recommendatory to help plan and evaluate resources radiological protection services. (Author)

  15. Radiological Evaluation Standards in the Radiology Department of Shahid Beheshti Hospital (RAH) YASUJ Based on Radiology standards in 92

    OpenAIRE

    A َKalantari; SAM Khosravani

    2014-01-01

    Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descri...

  16. Iliopsoas compartment lesions: a radiologic evaluation

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Amaral, Raquel Portugal Guimaraes; Abud, Thiago Giansante; Demarchi, Guilherme Tadeu Sauaia; Freire Filho, Edison de Oliveira; Novack, Paulo Rogerio; Campos, Flavio do Amaral; Shigueoka, David Carlos; Fernandes, Artur da Rocha Correa; Szejnfeld, Jacob; D'Ippolito, Giuseppe

    2007-01-01

    The iliopsoas compartment, a posterior boundary of the retroperitoneum, is comprised of the psoas major, psoas minor and iliac muscles. The symptoms picture in patients presenting with pathological involvement of this compartment may show a wide range of nonspecific clinical presentations that may lead to delayed diagnosis. However, in the search of an etiological diagnosis, it is already known that inflammation, tumors, and hemorrhages account for almost all the lesions affecting the iliopsoas compartment. By means of a retrospective analysis of radiological studies in patients with iliopsoas compartment lesions whose diagnosis was confirmed by anatomopathological evaluation or clinical follow-up, we have reviewed its anatomy as well as the main forms of involvement, with the purpose of identifying radiological signs that may help to narrow down the potential differential diagnoses. As each lesion is approached we will discuss the main radiological findings such as presence of gas in pyogenic abscesses, bone destruction and other bone changes of vertebral bodies in lesions secondary to tuberculosis, involvement of fascial planes in cases of neoplasms, and differences in signal density and intensity of hematomas secondary to hemoglobin degradation, among others. So, we have tried to present cases depicting the most frequent lesions involving the iliopsoas compartment, with emphasis on those signs that can lead us to a more specific etiological diagnosis. (author)

  17. Iliopsoas compartment lesions: a radiologic evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Amaral, Raquel Portugal Guimaraes; Abud, Thiago Giansante; Demarchi, Guilherme Tadeu Sauaia; Freire Filho, Edison de Oliveira; Novack, Paulo Rogerio; Campos, Flavio do Amaral; Shigueoka, David Carlos; Fernandes, Artur da Rocha Correa; Szejnfeld, Jacob; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Santos, Jose Eduardo Mourao [Universidade Federal de Sao Paulo (UNIFESP-EPM), Sao Paulo, SP (Brazil)

    2007-07-15

    The iliopsoas compartment, a posterior boundary of the retroperitoneum, is comprised of the psoas major, psoas minor and iliac muscles. The symptoms picture in patients presenting with pathological involvement of this compartment may show a wide range of nonspecific clinical presentations that may lead to delayed diagnosis. However, in the search of an etiological diagnosis, it is already known that inflammation, tumors, and hemorrhages account for almost all the lesions affecting the iliopsoas compartment. By means of a retrospective analysis of radiological studies in patients with iliopsoas compartment lesions whose diagnosis was confirmed by anatomopathological evaluation or clinical follow-up, we have reviewed its anatomy as well as the main forms of involvement, with the purpose of identifying radiological signs that may help to narrow down the potential differential diagnoses. As each lesion is approached we will discuss the main radiological findings such as presence of gas in pyogenic abscesses, bone destruction and other bone changes of vertebral bodies in lesions secondary to tuberculosis, involvement of fascial planes in cases of neoplasms, and differences in signal density and intensity of hematomas secondary to hemoglobin degradation, among others. So, we have tried to present cases depicting the most frequent lesions involving the iliopsoas compartment, with emphasis on those signs that can lead us to a more specific etiological diagnosis. (author)

  18. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    Directory of Open Access Journals (Sweden)

    Charikleia Triantopoulou

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts. The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm. This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation, the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins. Missed findings by imaging or pitfalls were recorded and we tried to explain all discrepancies between radiology evaluation and the histopathological findings. Radiologic-pathologic correlation is extremely important, adding crucial information on imaging limitations and enabling quality assessment of surgical specimens. The deep knowledge of different pancreatic tumors’ consistency and way of extension helps to improve radiologists’ diagnostic accuracy and minimize the radiological-surgical mismatching, preventing patients from unnecessary surgery.

  19. Radiological evaluation of the cervical spinal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J. [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1983-03-15

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal.

  20. Radiological evaluation of the cervical spinal trauma

    International Nuclear Information System (INIS)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J.

    1983-01-01

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal

  1. Radiological evaluation of esophageal motility and gastroesophageal reflux disease

    International Nuclear Information System (INIS)

    Schima, W.; Pokieser, P.; Schober, E.

    1995-01-01

    Radiological evaluation of esophageal motility and the lower esophageal sphincter has gained increased attention in recent years. Videofluoroscopic investigation of esophageal motor function is superior to static film radiography, as repeated analysis of the videotaped recordings is possible. With emphasis on radiological techniques, normal esophagel physiology and motility and a variety of esophageal motor disorders are discussed in this review paper. Radiological evaluation of gastroesophageal reflux and reflux esophagitis is described. Clinical and radiological findings in esophageal motility disorders and gastroesophageal reflux disease and the radiological efficacy compared to that of manometry and pH-metry are discussed. (orig.) [de

  2. Radiological and scintigraphic evaluation of hip prostheses

    International Nuclear Information System (INIS)

    Bessler, W.; Schaub, W.

    1979-01-01

    The radiological findings following the introduction of hip prostheses are often equivocal. Additional bone scintigrams often provide important information for the evaluation of the prostheses. 1. An unstable hip prosthesis is characterised by abnormal uptake in bone, due to static and mechanical stress. 2. A positive scintigram does not necessarily indicate instability of the prosthesis. Increased uptake may also be due to inflammatory bone changes, healing, bone replacement, abnormal local stresses or soft tissue calcification. 3. In evaluating the scintigram one must take account not only of the intensity of isotope uptake, but also its distribution and exact localisation. 4. It is essential to compare the scintigram with the radiograph. Radiological features of possible instability become diagnostic if they correspond with appropriate increased radioactivity. If the latter is absent, the of instability remains doubtful. 5. In some cases early loosening of the stem of the prosthesis can be diagnosed while the radiograph is still negative. Increased radioactivity in the acetabulum is frequently seen in the presence of a stable acetabular prosthesis and must be interpreted with caution as a sign of loosening of the prosthesis. (orig.) [de

  3. Radiology

    International Nuclear Information System (INIS)

    Meyers, M.A.

    1989-01-01

    This paper reports on disease processes originating within the alimentary tract, may extend through the extraperitoneal spaces, and abnormalities primarily arising within other extraperitoneal sites may significantly affect the bowel. Symptoms and signs may be obscure, delayed, or nonspecific, and the area is generally not accessible to auscultation, palpation, or percussion. Radiologic evaluation thus plays a critical role

  4. [Evaluation of patient doses in interventional radiology].

    Science.gov (United States)

    Ropolo, R; Rampado, O; Isoardi, P; Gandini, G; Rabbia, C; Righi, D

    2001-01-01

    To verify the suitability of indicative quantities to evaluate the risk related to patient exposure, in abdominal and vascular interventional radiology, by the study of correlations between dosimetric quantities and other indicators. We performed in vivo measurements of entrance skin dose (ESD) and dose area product (DAP) during 48 procedures to evaluate the correlation among dosimetric quantities, and an estimation of spatial distribution of exposure and effective dose (E). To measure DAP we used a transmission ionization chamber and to evaluate ESD and its spatial distribution we used radiographic film packed in a single envelope and placed near the patient's skin. E was estimated by a calculation software using data from film digitalisation. From the data derived for measurements in 27 interventional procedures on 48 patients we obtained a DAP to E conversion factor of 0.15 mSv / Gy cm2, with an excellent correlation (r=.99). We also found a good correlation between DAP and exposure parameters such as fluoroscopy time and number of images. The greatest effective dose was evaluated for a multiple procedure in the hepatic region, with a DAP value of 425 Gy cm2. The greatest ESD was about 550 mGy. For groups of patients undergoing similar interventional procedures the correlation between ESD and DAP had conversion factors from 6 to 12 mGy Gy-1 cm-2. The evaluation of ESD and E by slow films represents a valid method for patient dosimetry in interventional radiology. The good correlation between DAP and fluoroscopy time and number of images confirm the suitability of these indicators as basic dosimetric information. All the ESD values found are lower than threshold doses for deterministic effects.

  5. Evaluation in Radiology as a pedagogic contribution

    International Nuclear Information System (INIS)

    Ros Mendoza, L. H.

    2012-01-01

    After defining evaluation (a systematic process of data collection and analysis in order to take decisions in a specific field; in our case, radiology training at medical school), we should specify the characteristics of such evaluation, which include the aim (what for?), subject-matter (which content?), benchmarks (i.e., the standards against which we are comparing), when to evaluate, and how strictly or at what cost. Once these questions have been answered, we are able to select the most appropriate procedures for evaluation, bearing in mind that evaluation is a process, while grading implies an already made decision. There are different types of evaluation: the initial evaluation, which is not necessarily nominal, is performed to define the student’s level at the beginning of the course; the normative or norm-referenced evaluation has a relative nature, as it compares student achievement to that of others; and the absolute or criterion-referenced evaluation, which is based on established criteria, where the goals which should be achieved become the key element for designing teaching and evaluation. Evaluation may be used to generate motivation. This requires the establishment of clear and relevant objectives as well as knowledge on how to correct mistakes. Oral questions in the classroom may also be motivating. Within the triple domain to be taken into account (cognitive, affective and psychomotor), the objectives to be measured should be considered in a hierarchical order from simple to complex: necessary knowledge, comprehension of such concepts, practical application (in a context that is different from that where knowledge has been gained), and the so-called “superior operations” (analysis, synthesis and grading). Then, the technical features of evaluation will be defined: internal and external validity in relation to difficulty and discrimination; reliability, i.e. accuracy and consistency according to the degree of objectivity; and finally

  6. Evaluation of radiation protection conditions in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda Saicla; Rocha, Anna Silvia Penteado Setti da, E-mail: miguel_cristianoch@yahoo.com.br [Universidade Tecnologica Federal do Parana (PPGEB/UTFPR), Curitiba, PR (Brazil). Programa de Pos-graduacao em Engenharia Biomedica; Tilly Junior, Joao Gilberto [Universidade Federal do Parana (UNIR/UFPR), Curitiba, PR (Brazil). Hospital de Clinicas. Unidade de Imagem e Radioterapia; Almeida, Claudio Domingues de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Dept. de Fisica Medica

    2016-04-15

    Introduction: The dental radiology represents about 20% of human exposure to radiation in radio diagnostic. Although the doses practiced in intraoral dentistry are considered low, they should not be ignored due to the volume of the performed procedures. This study presents the radiation protection conditions for intraoral radiology in Curitiba - PR. Methods: Data was collected through a quantitative field research of a descriptive nature during the period between September of 2013 and December of 2014. The survey sample consisted of 97 dentists and 130 intraoral equipment. The data related to the equipment was collected using structured questions and quality control evaluations. The evaluations of the entrance skin dose, the size of the radiation field and the total filtration were performed with dosimetry kits provided and evaluated by IRD/CNEN. The exposure time and voltage were measured using noninvasive detectors. The occupational dose was verified by thermoluminescent dosimeters. The existence of personal protection equipment, the type of image processing and knowledge of dentists about radiation protection were verified through the application of a questionnaire. Results: Among the survey's results, it is important to emphasize that 90% of the evaluated equipment do not meet all the requirements of the Brazilian radiation protection standards. Conclusion: The lack of knowledge about radiation protection, the poor operating conditions of the equipment, and the image processing through visual method are mainly responsible for the unnecessary exposure of patients to ionizing radiation. (author)

  7. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  8. Pancreatic transplantation: Radiologic evaluation of vascular complications

    International Nuclear Information System (INIS)

    Snider, J.F.; Hunter, D.W.; Kuni, C.C.; Castaneda-Zuniga, W.R.; Letourneau, J.G.

    1991-01-01

    Transplantation of the pancreas is an increasingly common therapeutic option for preventing or delaying complications of type I diabetes mellitus. The authors studied the relative roles of various radiologic examinations in diagnosing vascular complications in these grafts including arterial and venous thrombosis, stenosis, and anastomotic leak (the most common vascular factors that necessitate pancreatectomy of the transplant), as defined with pathologic or arteriographic data. The results of 78 scintigraphic flow studies, 40 abdominal and pelvic computed tomographic (CT) scans, 27 sonograms, and eight color Doppler studies were evaluated in 52 patients who received a total of 27 cadaveric and 26 living-donor grafts over a 12-year period. These results were correlated with the data from 45 gross and microscopic pathologic studies and 37 arteriograms to determine their relative value in enabling detection of graft thrombosis and other vascular complications. Scintigraphy, CT, sonography, and color Doppler were all sensitive in detection of generalized graft abnormalities but lacked specificity in defining the underlying etiologic factors

  9. Pancreatic transplantation: Radiologic evaluation of vascular complications

    Energy Technology Data Exchange (ETDEWEB)

    Snider, J.F.; Hunter, D.W.; Kuni, C.C.; Castaneda-Zuniga, W.R.; Letourneau, J.G. (Univ. of Minnesota Hospital and Clinic, Minneapolis (USA))

    1991-03-01

    Transplantation of the pancreas is an increasingly common therapeutic option for preventing or delaying complications of type I diabetes mellitus. The authors studied the relative roles of various radiologic examinations in diagnosing vascular complications in these grafts including arterial and venous thrombosis, stenosis, and anastomotic leak (the most common vascular factors that necessitate pancreatectomy of the transplant), as defined with pathologic or arteriographic data. The results of 78 scintigraphic flow studies, 40 abdominal and pelvic computed tomographic (CT) scans, 27 sonograms, and eight color Doppler studies were evaluated in 52 patients who received a total of 27 cadaveric and 26 living-donor grafts over a 12-year period. These results were correlated with the data from 45 gross and microscopic pathologic studies and 37 arteriograms to determine their relative value in enabling detection of graft thrombosis and other vascular complications. Scintigraphy, CT, sonography, and color Doppler were all sensitive in detection of generalized graft abnormalities but lacked specificity in defining the underlying etiologic factors.

  10. Evidence-based radiology: a new approach to evaluate the clinical practice of radiology

    International Nuclear Information System (INIS)

    Puig, S.; Felder-Puig, R.

    2006-01-01

    Over the last several years, the concept and methodology of evidence-based medicine (EBM) have received significant attention in the scientific community. However, compared to therapeutic medical disciplines, EBM-based radiological publications are still underrepresented. This article summarizes the principles of EBM and discusses the possibilities of their application in radiology. The presented topics include the critical appraisal of studies on the basis on EBM principles, the explanation of EBM-relevant statistical outcome parameters (e.g., ''likelihood ratio'' for diagnostic and ''number needed to treat'' for interventional procedures), as well as the problems facing evidence-based radiology. Evidence-based evaluation of radiological procedures does not only address aspects of cost-effectiveness, but is also particularly helpful in identifying patient-specific usefulness. Therefore it should become an integral part of radiologist training. (orig.)

  11. Evaluations of gonad and fetal doses for diagnostic radiology.

    Science.gov (United States)

    Tung, C J; Tsai, H Y

    1999-07-01

    A national survey of patient doses for diagnostic radiology was planned in the Republic of China. We performed a pilot study for this survey to develop a protocol of the dose assessments. Entrance skin doses and organ (including ovary, testicle and uterus) doses were measured by thermoluminescent dosimeters and calculated by means of Monte Carlo simulations for several diagnostic procedures. We derived a formula and used the RadComp software for the computation of entrance skin doses. This formula involves several factors, such as kVp, mAs, the focus-to-skin-distance and aluminum filtration. RadComp software was applied to obtain free-air entrance exposures which were converted to entrance skin doses by considering the backscattering radiation from the body. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom for several diagnostic examinations. Genetically significant doses were calculated from ovary and testicle doses for the evaluation of hereditary effects. Embryo/fetal doses were determined from the uterine doses by considering the increase in uterus size with gestational age. We found that the patient doses studied in this work were all below the reference doses recommended by the National Radiological Protection Board of the U.K.

  12. Independent auto evaluation of an operative radiological protection program

    International Nuclear Information System (INIS)

    Medrano L, M.A.; Rodriguez C, C.C.; Linares R, D.; Zarate M, N.; Zempoalteca B, R.

    2006-01-01

    The program of operative radiological protection of a nuclear power plant consists of multiple procedures and associate tasks that have as purpose the radiological protection of the workers of the power station. It is for this reason that the constant evaluation of the one it programs it is an important tool in the identification of their weaknesses (and strengths), so they can be assisted appropriately. In this work the main elements of the program of independent auto evaluation of the program of operative radiological protection of the Laguna Verde Central that has been developed and implemented by the National Institute of Nuclear Research are described. (Author)

  13. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  14. User questionnaire to evaluate the radiological workspace

    NARCIS (Netherlands)

    van Ooijen, Peter M. A.; Koesoema, Allya P.; Oudkerk, Matthijs

    2006-01-01

    Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this

  15. Evaluation of radiological medical practice during night duty

    International Nuclear Information System (INIS)

    Tasu, J.P.; Rocher, L.; Miquel, A.; Rondeau, Y.; Blery, M.; Nguyen, D.T.; Spira, A.; Livartowski, J.; Ellrodt, A.

    2000-01-01

    To evaluate the radiological activity during night duty, in a University Hospital, during 100 days, the radiological activity has been evaluated from examinations requiring radiologist (including US and CT, special X-ray examinations). The urgent nature and the agreement between the suspected disease and the final diagnose have been compared with the level of the clinician (medical student, resident, senior). 981 radiological examinations were performed on an emergency basis. In 39%, the examination was urgent or very urgent and for 61% little urgent or non-urgent. The level of the clinician was correlated with the degree of emergency evaluated by the radiologist and with the agreement between suspected disease and the final diagnose (p<0.0001). During night duty, the medical activity in radiology is not justified only be emergency, but also the continuous hospital activities. Better formation of the physician is required to limit the number of examinations. (authors)

  16. Radiological evaluation of swallowing and clinical patterns of systemic sclerosis

    International Nuclear Information System (INIS)

    Montesi, A.; Pesaresi, A.; Cavalli, M.L.; Serri, L.; Salmistraro, D.; Candela, M.; Gabrielli, A.

    1990-01-01

    Fifty-one patients with systemic sclerosis (scleroderma) were studied by means of videofluoroscopy in order to evaluate the abnormalities in the oral-pharyngeal and esophageal phases of deglutition and to correlate the radiological patterns with the clinical features of the disease. Thirteen patients (25.5%) exhibited swallowing disorders such as oral leakage, retention, penetration, mild or moderate aspiration and abnormal upper esophageal sphincter behavior. These dysfunctions were more evident in patients with esophageal motility abnormalities. A normal radiological pattern in the esophagus was not associated with swallowing alterations. Remarkably, patients with oral-pharyngeal disorders had a higher incidence of lung diseases. Forty-five patients (88%) exhibited disorders of the esophageal phase of deglutition, such as mild or severe motility abnormalities or hiatal hernia, gastro-esophageal reflux, reflux esophagitis, and stricture. Radiological findings in the esophagus can be abnormal in the early stages of the disease. On the other hand, the radiological pattern of esophageal motility can be occasionally negative in advanced or extensive disease. This indicates a discrepancy between clinical symptoms and radiological picture of the esophagus. The radiological examination of the oral-pharyngeal and esophageal phases of deglutition is important in patients with scleroderma in order to evaluate visceral involvement, motility disorders, and risk of aspiration. Such radiological information can be useful in preventing esophagitis and pulmonary complications

  17. RADIOLOGICAL AND PATHOLOGICAL EVALUATION OF TRICHILEMMAL CYSTS OF THE SCALP

    Directory of Open Access Journals (Sweden)

    Deb Kumar Boruah

    2017-09-01

    Full Text Available BACKGROUND Trichilemmal cysts or pilar tumours are slow growing scalp lesion commonly found in elderly women. These slow growing lesions may cause morbidity and even mortality. Recurrence of the lesions after local excision is common. These trichilemmal cyst usually indolent with benign nature or may transform to proliferating trichilemmal cyst or Proliferating Pilar Tumour (PPT or may show malignant transformation. The aim of the study is to study the radiological and pathological evaluation of trichilemmal cysts of scalp. MATERIALS AND METHODS A hospital-based cross-sectional retrospective study was conducted. The study group comprised of 20 patients presenting to the Departments of Radiodiagnosis, Radiotherapy, General Surgery, Plastic Surgery and Dermatology in a tertiary care hospital from July 2015 to August 2017. All patients were initially evaluated clinically followed by cross-sectional imaging modality like Computed Tomography (CT or Magnetic Resonance Imaging (MRI. RESULTS In 20 patients, a total of 51 trichilemmal cysts were evaluated where 46 (90.2% were benign trichilemmal cysts and 5 (9.8% showed malignant transformation. The mean age of presentation was 47.9 yrs. ± 1.5 (SD with male:female ratio of 1:3.The mean duration of presence of trichilemmal cyst was 5.9 yrs. ± 3.2 (SD. Out of 5 malignant trichilemmal cysts 3 patients (15% showed bony calvarial erosion and 2 patients (10% showed intracranial extensions. Statistical significance with ‘p’ value of 0.003 was noted between the size of largest dimension of trichilemmal cyst and their histopathology without any statistical significance between duration of swelling and their histopathology. CONCLUSION Even though, the trichilemmal cysts of scalp are denoted as benign lesion, as they usually shows recurrence and its affinity to become locally aggressive and turn into malignancy is there. Hence, clinical, radiological and pathological correlation isnecessary to decreased

  18. Evaluation criteria for emergency response plans in radiological transportation

    International Nuclear Information System (INIS)

    Lindell, M.K.; Perry, R.W.

    1980-01-01

    This paper identifies a set of general criteria which can be used as guides for evaluating emergency response plans prepared in connection with the transportation of radiological materials. The development of criteria takes the form of examining the meaning and role of emergency plans in general, reviewing the process as it is used in connection with natural disasters and other nonnuclear disasters, and explicitly considering unique aspects of the radiological transportation setting. Eight areas of critical importance for such response plans are isolated: notification procedures; accident assessment; public information; protection of the public at risk; other protective responses; radiological exposure control; responsibility for planning and operations; and emergency response training and exercises. (Auth.)

  19. Radiological safety evaluation report for NUWAX-79 exercise

    International Nuclear Information System (INIS)

    King, W.C.

    1979-03-01

    An analysis of the radiological safety of the NUWAX-79 exercise to be conducted on the Nevada Test Site in April 1979 is given. An evaluation of the radiological safety to the participants is made using depleted uranium (D-38) in mock weapons parts, and 223 Ra and its daughters as a radioactive contaminant of equipment and terrain. The radiological impact to offsite persons is also discussed, particularly for people living at Lathrop Wells, Nevada, which is located 7 miles south of the site proposed for the exercise. It is the conclusion of this evaluation that the potential radiological risk of this exercise is very low, and that no individual should receive exposure to radioactivity greater than one-tenth of the level permitted under current federal radiation exposure guidelines

  20. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  1. Radiological evaluation of nonvisualizing kidney on IVP

    International Nuclear Information System (INIS)

    Moon, J. H.; Sung, K. B.; Cho, O. K.; Hahm, C. K.

    1983-01-01

    bladder carcinoma. CT was very useful for evaluation of extent of the diseases and regional or intraabdominal distant metastasis in one examination. 7. Ultrasonography was performed in 18 cases of various diseases. The size and gross contour of the kidney, hydronephrosis and focal masses were easily detectable with ultrasonography. In these cases, the confirmative diagnosis could be made by other studies including RGP or Renal Angiography

  2. Dosimetric evaluation program for dental radiology practices

    International Nuclear Information System (INIS)

    Gregori, B.; Milat, J.; Fernandez, J.; Micinquevich, S.; Andrieu, J.

    1992-01-01

    The preliminary results of a program undertaken to estimate the doses to patients associated with dental radiology practices in Argentine, are presented. Information collected from the search demonstrated that the Dieck and coronal techniques are the most commonly used practices, while all the examinations are performed by using a circular collimator. For both practices, the dosimetric studies were carried out on a Rando Alderson phantom. All dose measurements were made using thermoluminescent detectors LiF and Ca 2 F. In addition, a mathematical model was developed by applying the Monte Carlo method to a MIRD-V phantom. Circular and rectangular collimators were used. Absorbed dose distribution on head and neck, as well as surface dose distribution, were estimated. The comparison of the performance of both collimators shows that the use of the rectangular one allows for a dose reduction of 80%. Besides, a good correlation between the physical and mathematical models applied was found. (author)

  3. Radiologic evaluation of spinal epidural mass

    International Nuclear Information System (INIS)

    Lee, Ho Kyu; Lee, Moon Kyu; Chang, Kee Hyun

    1987-01-01

    It is often difficult to differentiate each pathologic entity among various spinal epidural masses on the radiologic basis. We retrospectively analysed radiologic findings of 67 cases of pathologically proven spinal epidural mass to find out any specific findings of each epidural mass. The results are as follows : 1. Of 67 cases, metastasis (16 cases), epidural abscess (15 cases), neurogenic tumor (16 cases) and meningioma (8 cases) are most common. The others consist of epidural angioma (3 cases), vertebral hemangioma (2 cases), chondrosarcoma (2 cases), fibrosarcoma (1 case), eosinophilic granuloma (1 case), lymphoma (1 case), lipoma (1 case) and lymphoid hyperplasia (1 case). 2. Destruction of the adjacent bone was commonly associated with the epidural mass in metastasis (75%) and epidural abscess (67%). It was also noted in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 3. Pressure erosion of adjacent bone was demonstrated in neurogenic tumor (75%) and meningioma (25%). 4. Narrowing of intervertebral space was seen in only 27% of epidural abscess. 5. The paraspinal tumor was associated in 67% of metastasis, 80% of epidural abscess, 75% of neurogenic tumor, 33% of meningioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 6. The intradural tumor was associated in 50% of neurogenic tumor and 67% of meningioma. 7. On axial CT image, most of the epidural mass shows eccentric location with displacing dural sac to the opposite side. The diseases that occasionally show encircling location are metastasis, epidural abscess, vertebral hemangioma, chondrosarcoma, eosinophilic granuloma, and lymphoma. Neurogenic tumor only shows multicentric location. 8. The disease extent more than height of one vertebral body was seen in 80% of epidural abscess, 58% of neurogenic tumor, 100% of epidural angioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma, 1 eosinophilic granuloma, 1 lymphoma, 1

  4. Radiological Evaluation Standards in the Radiology Department of Shahid Beheshti Hospital (RAH YASUJ Based on Radiology standards in 92

    Directory of Open Access Journals (Sweden)

    A َKalantari

    2014-08-01

    Full Text Available Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descriptive statistics. Results: 87.3% of the students chose the cassette, 76.3%, patients chose the position, 87.3%, member state, the central ray 83.9%, and the distance between the tube and the patient 68.6% had been operated in accordance with the standards practice. Among all the factors and variables, between view with cassette, view with SID, sex with position patients, grid with central ray, grid with SID, Request with positioning the patient and between density with patient position and member position significant relationship were observed p<0.05 . Conclusions: Staff and students in terms of performance were at high levels, but in the levels of protection were in poor condition. Therefore, in order to promote their conservation, education and periodical monitoring should be carried out continuously.

  5. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453

    International Nuclear Information System (INIS)

    Costa, Rogerio Ferreira da

    2013-01-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  6. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  7. Radiological and clinical evaluation of colorectal cancer

    International Nuclear Information System (INIS)

    Shin, O. J.; Chin, S. Y.; Lee, K. S.; Park, S. S.

    1982-01-01

    One hundred thirty two cases of the pathologically proven colorectal cancer at Korea Atomic Energy Research Institute Hospital in the period from January 1973 to June 1980 were analyzed radiologically and clinically. The results were as follows: 1. The colorectal cancer was prevalent in rectosigmoid area and in the fourth to seventh decade of life. 2. The clinical pictures were classified into two groups. The one was rectosigmoid cancer with bowel habit changes. The other was one with no specific symptoms or signs. The clinical pictures of the right colon cancer were rather indirected, chronic and systemic than those of the left one. 3. The roentgenological findings were classified into two groups. The one was rectum and left colon cancer with symmetrical annular narrowing and the other showed trumpet-like proximal dilatation. 4. The most frequent complication was intestinal obstruction. 5. The majority of colorectal cancer was adenocarcinoma. The squamous cell carcinoma and atypical cell carcinoma were most prevalent in rectum, but malignantly lymphoma often occurred in right colon. The rarest colorectal cancer was atypical cell carcinoma in rectum

  8. Radiological evaluation of chinchilla mastication organs

    International Nuclear Information System (INIS)

    Sulik, M.; Sobolewska, E.; Ey-Chmielewska, H.; Fraczak, B.; Seremak, B.

    2007-01-01

    The studies were undertaken in order to analyse radiologically bone structures of the maxilla and mandibula including the teeth in chinchillas that show pathological overgrowth of incisor and molar teeth. The analysis included 10 sick and 10 healthy animals, whose skulls were post-mortem dissected and compared. The x - ray pictures were examined for significant elements of the bone structure; shape and saturation of incisor and molar teeth, shape, saturation, and thickness of cranial sutures, as well as the evenness of the intensity of the symptoms. The structure of the incisor teeth revealed excessive tissue mineralisation. The tooth canal was invisible, which may indicate fibrosis of the pulp. The cutting edges exhibited excessive mineralisation, which implied a lack of abrasion. The pulp growth cone was invisible. The shape of the upper incisor was altered and semicircular, this prevented contact between the edges of the opposing teeth. The surface structure of the molars was considerably saturated with invisible dental pulp, which may imply fibrosis. The roots of the teeth were distended and flask-like inb shape, and considerably saturated. The visible excessive mineralisation in all the molar teeth implied a general process of osteosclerosis. (author)

  9. Radiology education. The evaluation and assessment of clinical competence

    International Nuclear Information System (INIS)

    Hibbert, Kathryn M.; Van Deven, Teresa; Chhem, Rethy K.; Nagasaki Univ.; Wang, Shih-chang; Royal Australian and New Zealand College of Radiologists, Sydney

    2012-01-01

    Third volume of a trilogy devoted to radiology education and improvement of medical imaging students' learning, teaching, and scholarship. Reviews the philosophies, theories, and principles that underpin assessment and evaluation in radiology education. Includes a series of rich case studies. Written by an international group of experienced educators and medical professionals. This book reviews the philosophies, theories, and principles that underpin assessment and evaluation in radiology education, highlighting emerging practices and work done in the field. The sometimes conflicting assessment and evaluation needs of accreditation bodies, academic programs, trainees, and patients are carefully considered. The final section of the book examines assessment and evaluation in practice, through the development of rich case studies reflecting the implementation of a variety of approaches. This is the third book in a trilogy devoted to the scholarship of radiology education and is the culmination of an important initiative to improve medical imaging students' learning, teaching, and scholarship by bringing together experienced educators and medical professionals. The previous two books focused on the culture and the learning organizations in which our future radiologists are educated and on the application of educational principles in the education of radiologists. Here, the trilogy comes full circle: attending to the assessment and evaluation of the education of its members has much to offer back to the learning of the organization.

  10. Evaluation of medical radiation exposure in pediatric interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Valeria Coelho Costa; Navarro, Marcus Vinicius Teixeira; Oliveira, Aline da Silva Pacheco, E-mail: vccnavarro@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil); Maia, Ana Figueiredo [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Oliveira, Adriano Dias Dourado [Sociedade Brasileira de Hemodinamica e Cardiologia Intervencionista, Salvador, BA (Brazil)

    2012-07-15

    Objective: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. Materials and Methods: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. Results: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm{sup 2} and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm{sup 2} and 961.0 mGy. Conclusion: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates. (author)

  11. Radiologic evaluation of carcinoma of the gallbladder

    International Nuclear Information System (INIS)

    Kim, I. Y.; Kim, K. W.; Yoo, H. S.; Lee, J. T.; Park, C. Y.

    1983-01-01

    Thirty five cases of pathlogically proven carcinoma of the gallbladder at Yonsei Univ. College. of Med. Severance Hospital in the period from May, 1978 to Oct, 1982 were analyzed radiologically and clinically. The brief results are as follows: 1. The ratio of male to female was 1 : 1.2 and prevalent in the sixth decade of life. 2. Clinical feature show RUQ pain in 24 cases. Epigastric pain in 13 cases and jaundice in 6 cases, symptom duration is variable from 1 week to over year. 3. Oral and IV cholangiography were performed in 17 cases. Nonvisualization of gallbladder was observed in 14 cases. Filling defect in gallbladder was observed in 2 cases and air biliarygram is observed in 1 case. 4. UGI series was performed in 11 cases. Postbulbar indentation was observed in 9 cases, gastric antrum indentation in 2 cases, postbulbar indentation with adhesion in 2 cases and normal finding was observed in 2 cases. 5. PTC was performed in 7 cases. Nonvisualization of gallbladder was observed in 7 cases, abrupt obstruction at porta hepatis in 3 cases, abrupt eccentric obstruction extrahepatic duct at cystic duct level in 2 cases, lobulated mass effect in extrahepatic duct at the level of cystic duct opening in 1 case. Round swing of extrahepatic duct with dilatation was observed in 1 case. 6. ERCP was performed in 11 cases. Nonvisualization of gallbladder was observed in 8 cases, irregular large intraluminal filling defect in 2 cases, multiple stone in 1 case, abrupt narrowing proximal CBD in 3 cases, extrinsic mass effect in CHD was observed in 1 case. 7. Celiac angiography was performed in 3 cases. Cystic artery hypertrophy was observed in 1 case and halo appearance in gallbladder area was observed in 1 case. 8. Ultrasound for investigation of carcinoma of gallbladder was performed in 16 cases. Homogenous echoes in gallbladder was observed in 6 cases, Bull's eye appearance in 4 cases, fungasting mass in

  12. Evaluation of radiological exposure from Plowshare applications, 1967--1975

    International Nuclear Information System (INIS)

    Barton, C.J.; Kaye, S.V.

    1975-08-01

    A review of the highlights and accomplishments of the nine-year program, FY 1967-75, at ORNL on the evaluation of the radiological exposure from Plowshare applications is presented. Conclusions based on the studies summarized are given. Chronological lists of presentations, reports and open literature publications on the various investigations of the program are appended to the report. (auth)

  13. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A.; Oudkerk, Matthijs; Van Ooijen, Peter M. A.

    Objectives: To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical

  14. Radiological evaluation of the response to chemotherapy for osteosarcoma

    International Nuclear Information System (INIS)

    Miwa, Shinji; Taki, Junichi; Yamamoto, Norio

    2011-01-01

    Sixty-one patients with osteosarcoma were examined by radiographs, angiograms, MRI, 201 Tl and 99m Tc-methoxyisobutyl-isonitrile (MIBI) scintigram to evaluate their response to preoperative chemotherapy. All patients were classified as either responders or non-responder according based on the imaging findings. The radiographs were evaluated according to the degree of sclerotic change and cortical recovery, and the angiograms were evaluated according to the degree of vascular change. MR images were evaluated according to the rate of extraskeletal mass reduction. The 201 Tl and 99m Tc-MIBI scans were evaluated by the percentage reduction of the uptake ratio. All patients were evaluated on the basis of a pathological examination of the resected specimens. We also devised a combined radiological scoring system according to the predictive power of each type of diagnostic image and investigated the correlation between the radiological evaluation and the pathological evaluation. Sensitivity, specificity, and accuracy were 81.0%, 19.0%, and 60.3%, respectively for the radiographs; 77.1%, 20.0%, and 60.0%, respectively, for angiograms; 82.1%, 69.0%, and 75.4%, respectively for MRI; 81.5%, 68.0%, and 75.0%, respectively, for 201 Tl scans; 76.7%, 70.6%, and 74.5% for 99m Tc-MIBI scans; and 88.9%, 84.0%, and 86.9%, respectively, for the combined radiological evaluation. (author)

  15. Radiation dose evaluation in patients submitted to conventional radiological examinations

    International Nuclear Information System (INIS)

    Tilly Junior, Joao G.

    1997-01-01

    This work presents the results of the evaluation of radiation dose delivered to the patients undergoing conventional radiological procedures. Based in the realized measurement some indicators are settled to quantitative appraisal of the radiological protection conditions offered to the population. Data assessment was done in the county of Curitiba, in Parana State, Brazil, from 12/95 to 04/96, in ten rooms of three different institutions, under 101 patients, adults with 70 ± 10 kg, during real examinations of chest PA, chest LAT and abdomen AP. (author)

  16. Evaluation of the effectiveness of gonad protection in diagnostic radiology

    International Nuclear Information System (INIS)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describes the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60). (author)

  17. [Evaluation of the effectiveness of gonad protection in diagnostic radiology].

    Science.gov (United States)

    Kawaura, Chiyo; Aoyama, Takahiko; Koyama, Shuji

    2004-01-01

    In the present study we describe the evaluation of the effectiveness of gonad protection in diagnostic radiology based on the measurement of organ and the effective doses with and without lead clothing to gonads. We devised in-phantom dosimetry system and measured organ and effective doses in x-ray radiography and CT examinations with the new dosimetry system. From the data of organ and the effective doses we assessed the effectiveness of radiological protection by the use of lead clothing to gonads. Although in chest radiography and chest CT examinations, the effectiveness of radiological protection was not found, in the case of hip joint radiography (AP), gonad doses decreased remarkably by using lead clothing. The effectiveness of radiological protection, i.e. the ratio of the decreased dose to the dose value without protection, in testis and ovary were found to be 91.4% and 68.0%, respectively. It was also found that gonad doses observed with and without gonad protection were extremely lower than those of threshold for sterility recommended by the International Commission on Radiological Protection 60 (ICRP Publ. 60).

  18. Computerization of radiology departmental management using the personal computer: application in medium sized hospital

    International Nuclear Information System (INIS)

    Ahn, Woo Hyun

    1992-01-01

    The author developed a computer program for use in registration, monthly statistics, printing of reports, data storage and retrieval in the Radiology department. This program has been used in the Department of Radiology, MoonHwa Hospital since November 1990. This program was written in FoxBASE language, consisted of two independent subprograms, one installed in a registration computer without a printer and another in a reporting computer with a printer. The subprograms were designed to link their data by floppy disk. Each computer's hard disk contained permanent files for retrieval and temporary files for data input. All permanent files were indexed on several keywords including the patient's identification data. 1. Registration was performed easily and rapidly. 2. A monthly statistic was obtained simply. 3. Retrieval of the results of previous radiologic studies, printing of report, storage and indexing of data were achieved automatically. This program had merits of simple operation, large storage capacity, rapid retrieval speed, relative low price, easy adjustment for other hospitals. Therefore this program is considered to be an economic substitute for computerization of radiology departmental management in medium sized hospitals

  19. Radiologic evaluation of nonalcoholic fatty liver disease

    Science.gov (United States)

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  20. Radiologic evaluation of neonatal and childhood hypertension

    International Nuclear Information System (INIS)

    Amour, T.S.; Siegel, M.J.

    1986-01-01

    The authors reviewed the radiographic findings in 40 neonates and 90 children and adolescents with hypertension. In neonates the common causes of secondary hypertension were renal vascular thrombosis (33%), polycystic kidney disease (25%), and obstructive uropathy (17%). US and renal scans were the most useful studies and yielded diagnostic information in approximately 70% of cases. Surgically correctable hypertension was found in almost half the patients. In patients over 1 year of age, the common causes of hypertension were medical renal disease (50%) and renovascular hypetension (15%). Urography, scintigraphy, and arteriography played a crucial role in their evaluation

  1. Radiological evaluation of the acromioclavicular joint

    International Nuclear Information System (INIS)

    Vaeaetaeinen, U.; Maekelae, A.; Pirinen, A.

    1991-01-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.)

  2. Radiological evaluation of the acromioclavicular joint

    Energy Technology Data Exchange (ETDEWEB)

    Vaeaetaeinen, U.; Maekelae, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Surgery); Pirinen, A. (Kuopio Univ. Central Hospital (Finland). Dept. of Radiology)

    1991-02-01

    X-ray measurement of the acromioclavicular (AC) joint may cause difficulties because of different projections and the lack of a reproducible measurement. In order to find the ideal measurement to estimate the state of the AC joint, 28 healthy adult volunteers were X-rayed. The least vulnerable measurement for errors in projection was the distance between the coracoid process and the upper part of the clavicle. The effect of stress was evaluated; the range of normal AC joint laxity was determined as 3 mm. (orig.).

  3. Solid bolus swallowing in the radiologic evaluation of dysphagia

    International Nuclear Information System (INIS)

    Westen, D. van; Ekberg, O.

    1993-01-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.)

  4. Solid bolus swallowing in the radiologic evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Westen, D. van (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden)); Ekberg, O. (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden))

    1993-07-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.).

  5. Evaluation of the integrity of radiological protection clothing used in veterinary radiology

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Paola da Costa; Barros, Frieda Saicla; Costa, Douglas Siqueira da, E-mail: paah_dacosta@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Curso Superior de Tecnologia em Radiologia e Programa de Pos-Graduacao em Engenharia Biomedica

    2017-11-01

    This study aimed to evaluate the integrity of radiological protection clothing used by veterinarians in veterinary radiology facilities, and whether they are available in an adequate quantity for the team. Inspection was performed by palpation, followed by X-ray scanning in 189 clothing from 29 veterinary facilities. The results indicate that 5% of the clothes evaluated in this study were considered inadequate due to the failure of the integrity of the lead, being most lead aprons. All facilities have at least two lead aprons and one Thyroid protectors. 24% of the facilities have lead glasses, pointing to a risk to veterinarians by radiosensitivity of the eyes. Also, 24% of the facilities do not have lead gloves, which also presents a risk due to the hand's exposure to the primary beam. Most lead clothing has shield equivalence of 0.5mmPb. The method used in the study was effective in attesting the adequacy of lead clothing. It is recommended to periodically evaluate clothing to ensure that users are always protected. (author)

  6. Evaluation of the integrity of radiological protection clothing used in veterinary radiology

    International Nuclear Information System (INIS)

    Rosa, Paola da Costa; Barros, Frieda Saicla; Costa, Douglas Siqueira da

    2017-01-01

    This study aimed to evaluate the integrity of radiological protection clothing used by veterinarians in veterinary radiology facilities, and whether they are available in an adequate quantity for the team. Inspection was performed by palpation, followed by X-ray scanning in 189 clothing from 29 veterinary facilities. The results indicate that 5% of the clothes evaluated in this study were considered inadequate due to the failure of the integrity of the lead, being most lead aprons. All facilities have at least two lead aprons and one Thyroid protectors. 24% of the facilities have lead glasses, pointing to a risk to veterinarians by radiosensitivity of the eyes. Also, 24% of the facilities do not have lead gloves, which also presents a risk due to the hand's exposure to the primary beam. Most lead clothing has shield equivalence of 0.5mmPb. The method used in the study was effective in attesting the adequacy of lead clothing. It is recommended to periodically evaluate clothing to ensure that users are always protected. (author)

  7. Exercises for radiological and nuclear emergency response. Planing - performance - evaluation

    International Nuclear Information System (INIS)

    Bayer, A.; Faleschini, J.; Goelling, K.; Stapel, R.; Strobl, C.

    2010-01-01

    The report of the study group emergency response seminar covers the following topics: (A) purpose of exercises and exercise culture: fundamentals and appliances for planning, performance and evaluation; (B) exercises in nuclear facilities; (C) exercises of national authorities and aid organizations on nuclear scenarios; exercises of national authorities and aid organizations on other radiological scenarios; (D) exercises in industrial plants, universities, medical facilities and medical services, and research institutes; (E) transnational exercises, international exercises; (F): exercises on public information.

  8. Radiological evaluation of lung volume among Koreans with silicosis

    International Nuclear Information System (INIS)

    Rhee, Byung Chull

    1975-01-01

    1. Radiological evaluation of lung volumes was carried out thirty Korean males patients with silicosis, and following results were obtained. 2. The mean radiological lung volume among those patients was 7,587 ml. 3. When compared with the group of normal Korean male adults ranging from 31 to 55 years of age, the mean lung volume was increased by 2,346 ml. 4. The lung volume of these patients was even slightly larger than that of the group of Korean athletes of all ages. 5. On the other hand, the vital capacity in patients with silicosis was markedly diminished, the mean vital capacity being 2,909 ml. 6. The patients with silicosis also revealed emphysematous changes in the lung as well as increased residual volumes. The vital capacity was smallest in the latest stage.

  9. Dose Evaluation and Quality Criteria in Dental Radiology

    International Nuclear Information System (INIS)

    Gori, C.; Rossi, F.; Stecco, A.; Villari, N.; Zatelli, G.

    2000-01-01

    Radioprotection in dental radiology is of particular interest in the framework of the Revised Medical Exposure Directive for the great number of examinations involving the adult as well as the paediatric population (Article 9: Special Practice). The present study is intended to find the quality criteria of orthodontic imaging and for evaluating the dose absorbed within the dental and maxillary volume in connection with radiological examinations performed with either spiral CT, dental panoramic tomography or teleradiography. The X ray dose to organs sited in the body, neck, ocular and intracranial area was measured using lithium fluoride dosemeters, positioned in a Rando phantom. Quality criteria have been established by an expert radiologist considering the diagnostic information obtained in the images. The dosimetric data obtained were comparable with other authors', although with some differences due to technical characteristics. These result data are useful for choosing the patient's diagnostic path, considering the radiobiological risk associated with increasing orthodontic imaging. (author)

  10. Evaluation of radiological protection aspects in radiodiagnostic rooms in Mexico City

    International Nuclear Information System (INIS)

    Escobar A, L.; Vizuet G, J.; Ruiz, M.A.

    1996-01-01

    The preliminary results of an evaluation of radiological protection carried out in radiology services of different hospitals of Mexico are shown. The evaluated points were: relative aspects of the room, operation parameters of operation of the equipment, work procedures and training about radiological protection for the equipment operators. (authors). 2 refs., 1 fig

  11. Radiologic evaluation of the liver in the alcoholic patient

    International Nuclear Information System (INIS)

    Peng, J.J.; Hirsch, G.; Posteraro, R.H.; Leo, J.S.; Blackwell, D.E.

    1985-01-01

    It has been well documented that long-term abuse of alcohol leads to dysfunction of multiple organ systems of the body. The liver, which is the primary organ responsible for alcohol metabolism, is also a major target for damage. Cirrhosis of the liver is the seventh leading cause of death in the United States. The radiologist plays an important role in the evaluation and possibly in the treatment of the conditions which result from alcohol abuse. The advantages and limitations of various radiologic diagnostic modalities in the evaluation of alcoholic liver disease are presented and discussed. 47 references

  12. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  13. Dosskin code for radiological evaluation of skin radioactive contaminations

    International Nuclear Information System (INIS)

    Cornejo D, N.

    1996-01-01

    The conceptual procedure and computational features of the DOSSKIN code are shown. This code calculates, in a very interactive way, skin equivalent doses and radiological risk related to skin radioactive contaminations. The evaluation takes into account the contributions of contaminant daughter nuclides and backscattering of beta particles in any skin cover. DOSSKIN also allows to estimate the maximum time needed to decontaminate the affected zone, using, as input quantity, the limit value of skin equivalent dose considered by users. The comparison of the results obtained by the DOSSKIN code with those reported by different authors are showed. The differences of results are less than 30%. (authors). 4 refs., 3 fig., 1 tab

  14. Radiological evaluation of G-I tract diverticulum in Korean

    International Nuclear Information System (INIS)

    Sung, Ki Jun; Park, Joong Wha; Hong, In Soo; Kim, Myung Soon

    1986-01-01

    We reviewed 887 cases of esophagogram, 8863 cases of UGI series, 174 cases of small bowel series and 1926 cases of double contrast barium enema performed at the department of Radiology, Wonju College of Medicine from Jan. 1982 to Dec. 1984 to analyzed diverticular disease pattern of the GI tract in Korean. The results were as follows: 1. Esophageal diverticular. The incidence was 3.27% and the sex ratio of male to female was 2.22:1 Age distribution was relatively even and most common in 5th decade. Most of them showed single in number, above 6mm sized and common in middle one third of both lateral side of esophagus. 2. Stomach diverticular. The incidence was 0.07% and the sex ratio of male to female was equal. Multiplicity was single in all cases. Most of them were above 11mm sized and common in gastric fundic area of greater curvature site of stomach. 3. Duodenal diverticular. The incidence was 1.51% and relatively even distribution in sex and age and common in after 5th decade. Most of them showed single in number, 11-30mm sized and common in medial margin of 2nd portion of duodenum. 4. Colonic diverticular. The incidence was 2.34% and predominant in male and common in 5th. and 6th. decade. Most of them showed single in number, below 5mm sized and common in right sided colon.

  15. Radiological evaluation of G-I tract diverticulum in Korean

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ki Jun; Park, Joong Wha; Hong, In Soo; Kim, Myung Soon [Yeonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    1986-12-15

    We reviewed 887 cases of esophagogram, 8863 cases of UGI series, 174 cases of small bowel series and 1926 cases of double contrast barium enema performed at the department of Radiology, Wonju College of Medicine from Jan. 1982 to Dec. 1984 to analyzed diverticular disease pattern of the GI tract in Korean. The results were as follows: 1. Esophageal diverticular. The incidence was 3.27% and the sex ratio of male to female was 2.22:1 Age distribution was relatively even and most common in 5th decade. Most of them showed single in number, above 6mm sized and common in middle one third of both lateral side of esophagus. 2. Stomach diverticular. The incidence was 0.07% and the sex ratio of male to female was equal. Multiplicity was single in all cases. Most of them were above 11mm sized and common in gastric fundic area of greater curvature site of stomach. 3. Duodenal diverticular. The incidence was 1.51% and relatively even distribution in sex and age and common in after 5th decade. Most of them showed single in number, 11-30mm sized and common in medial margin of 2nd portion of duodenum. 4. Colonic diverticular. The incidence was 2.34% and predominant in male and common in 5th. and 6th. decade. Most of them showed single in number, below 5mm sized and common in right sided colon.

  16. Evaluation of PC-based diagnostic radiology workstations

    International Nuclear Information System (INIS)

    Pollack, T.; Brueggenwerth, G.; Kaulfuss, K.; Niederlag, W.

    2000-01-01

    Material and Methods: During February 1999 and September 1999 medical users at the hospital Dresden-Friedrichstadt Germany had tested 7 types of radiology diagnostic workstations. Two types of test methods were used: In test type 1 ergonomic and handling functions were evaluated impartial according to 78 selected user requirements. In test type 2 radiologists and radiographers (3+4) performed 23 work flow steps with a subjectively evaluation. Results: By using a progressive rating no product could fully meet the user requirements. As a result of the summary evaluation for test 1 and test 2 the following compliance rating was calculated for the different products: Rad Works (66%), Magic View (63%), ID-Report (58%), Impax 3000 (53%), Medical Workstation (52%), Pathspeed (46%) and Autorad (39%). (orig.) [de

  17. Quality of life evaluation of workers for diagnostic radiology services

    International Nuclear Information System (INIS)

    Fernandes, Ivani Martins

    2011-01-01

    The main objective of this study was to evaluate the quality of life (QOL) of diagnostic radiology services workers at a hospital of Sao Paulo city. It aimed also to draw the profile of these workers identifying the variables, as its influence on their quality of life. A descriptive exploratory study with qualitative and quantitative approaches was carried out. The data were collected using the questionnaires: the abbreviated instrument for the assessment of the QOL, World Health Organization Quality of Life Instrument bref (WHOQOL-bref) and a questionnaire including the social demographic variables, work conditions and the variables that express the lifestyle of individuals, both questionnaires self-applied. The sample was formed by 118 workers, among them: physicians, technologists/technicians in radiology, nurses, technicians and assistants in nursing, and others health professionals. The data analysis included descriptive statistics, nonparametric tests and the use of a linear regression model. The reliability of the instrument for the studied sample was verified by Cronbach's Alpha Coefficient (α). The WHOQOL-bref proved to be an adequate instrument, with a good level of internal consistency (α=0.884), being easily and quickly administrated for the evaluation of the QOL. The study provided an overview of the perception of quality of life of the studied group. (author)

  18. Radiologic evaluation of the globus symptom using videotape recorder

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Chung, Tae Sub; Lee, Jong Tae; Yoo, Hyung Sik; Suh, Jung Ho; Chang, Tae Young; Park, In Yong

    1988-01-01

    The authors examined barium swallow in 213 patients with globus symptom and 79 patients with vague gastric problems without globus symptom. Abnormal findings were more frequently detected on videorecording than on conventional esophagogram. Radiologic findings were transient cricopharyngeal indentation (CPI), residual barium collection and delayed clearing from hypopharynx (RB), laryngeal penetration of barium, barium retention in vallecula and or pyriform sinuses. Among them residual barium in hypopharynx was more frequently detected in patients with globus symptom than in patients without globus symptom. Globus symptom was more frequent in adult women, but age and sex difference did not affect the incidence of the abnormal radiologic findings. Cricopharyngeal indentation was most frequently seen at the level of C5-6 interspace and had a tendency of moving upward gradually during the indentation in about half of the cases. Most of the CPI was seen in early phase of swallowing and was visible within 1 sec. Residual barium collection was mostly seen in C6 or C6-7 level. RB had no cause and effect relationship with CPI, and it was not secondary result of obstructive effect of CPI. The authors think that videotape recording can be a useful method for evaluation of globus symptom. The residual barium collection in hypopharynx can be a significant finding in globus symptom

  19. Evaluation of a high-level waste radiological maintenance facility

    International Nuclear Information System (INIS)

    Collins, K.J.

    1998-01-01

    The Savannah River Site''s (SRS) Defense Waste Processing Facility (DWPF) near Aiken, SC is the nation''s first and world''s largest high level waste vitrification facility. DWPF began, operations in March 1996 to process radioactive waste, consisting of a matrixed predominantly 137 Cs precipitate and a predominately 90 Sr and alpha emitting sludge, into boro-silicate glass for long term storage. Presently, DWPF is processing only sludge waste and is preparing to process a combination of sludge and precipitate waste. During precipitate operations, canister dose rates are expected to exceed 10 Sv hr -1 (1000 rem hr -1 ). In sludge-only operations, canister contact gamma dose rates are approximately 15 mSv hr -1 (1500 mrem hr -1 ). Transferable contamination levels have been greater than 10 mSv hr -1 (100 cm 2 ) -1 for beta-gamma emitters and into the millions of Bq (100 cm 2 ) -1 for the alpha emitting radionuclides. This paper presents an evaluation of the radiological maintenance areas and their ability to support radiological work

  20. Radiologic evaluation of adriamycin induced toxic cardiomyopathy in childhood leukemia

    International Nuclear Information System (INIS)

    Kim, Young Joo; Moon, Young Hee; Kang, Kyung Jin; Kim, Ok Hwa; Kim, Choon Yul; Bahk, Yong Whee

    1992-01-01

    The cardiomyopathy associated with Adriamycin is frequently fatal and full clinical recovery is uncommon. To evaluate the radiological manifestation and the outcome of Adriamycin induced cardiac toxicity, we retrospectively reviewed the serial chest X-ray films of children treated with Adriamycin. Among 154 children with leukemia, fourteen patients developed clinical and radiologic evidence of congestive heart failure (CHF). Six out of 14 (43%) died of CHF within 2 weeks after attack and eight children survived after their acute episodes of CHF, were controlled following digoxin and diuretic therapy. Despite the improving clinical evidence of heart failure, the follow-up chest roentgenograms of these 8 children showed definite cardiomegaly as compared with the pre-treatment chest X-ray. Three children among 8 had minimal cardiomegaly and the remaining five children showed persistent, marked cardiomegaly during the period of 9-25 months of follow up. In summary, when CHF develops during chemotherapy in leukemic children, the possibility of Adriamycin induced cardiac toxicity should be suspected. Our findings showed that persistence of cardiomegaly represented significant cardiomyopathy despite clinical improvement of CHF

  1. Radiologic evaluation of the maxillary natural pathologic conditions in children

    International Nuclear Information System (INIS)

    Prk, Tae Won; Choi, Soon Chul

    1992-01-01

    The authors evaluated the distribution of the antral pathologic conditions and their radiographic features on the Waters' radiographs of 151 children patients who had been radiographed at the department of Oral Radiology, Seoul National University Hospitals. The obtained results were as follows : 1. The most common pathologic condition was inflammatory change (58%). Percentage of cases showing cystic lesion and fibro-osseous lesion were 25% and 11% respectively. 2. In cases of inflammatory change, odontogenic origins were 12 cases (13%) and bilateral occurrences were 37 cases (39%). 3. The most common radiographic feature of the inflammatory conditions was various types of mucosal thickening (78%). Percentage of cases showing totally increased radiopacity was 18%. 4. Intrinsic cystic lesions were 26 cases (65%) and dentigerous cyst was the most common extrinsic cyst. 5. Most of the fibro-osseous lesions (15 from 17 cases) were fobrous dysplasea. 6. Maxillary sinus hypoplasia (5 cases) and Burkitt's lymphoma (4 cases) were also observed.

  2. Radiologic evaluation of the maxillary natural pathologic conditions in children

    Energy Technology Data Exchange (ETDEWEB)

    Prk, Tae Won; Choi, Soon Chul [Dept. of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1992-08-15

    The authors evaluated the distribution of the antral pathologic conditions and their radiographic features on the Waters' radiographs of 151 children patients who had been radiographed at the department of Oral Radiology, Seoul National University Hospitals. The obtained results were as follows : 1. The most common pathologic condition was inflammatory change (58%). Percentage of cases showing cystic lesion and fibro-osseous lesion were 25% and 11% respectively. 2. In cases of inflammatory change, odontogenic origins were 12 cases (13%) and bilateral occurrences were 37 cases (39%). 3. The most common radiographic feature of the inflammatory conditions was various types of mucosal thickening (78%). Percentage of cases showing totally increased radiopacity was 18%. 4. Intrinsic cystic lesions were 26 cases (65%) and dentigerous cyst was the most common extrinsic cyst. 5. Most of the fibro-osseous lesions (15 from 17 cases) were fobrous dysplasea. 6. Maxillary sinus hypoplasia (5 cases) and Burkitt's lymphoma (4 cases) were also observed.

  3. Evaluation of radiological teaching programs in the Internet

    International Nuclear Information System (INIS)

    Seitz, J.; Schubert, S.; Voelk, M.; Scheibl, K.; Paetzel, C.; Schreyer, A.; Djavidani, B.; Feuerbach, S.; Strotzer, M.

    2003-01-01

    Evaluation of web based training programs,which can be contacted from the homepages of radiological departments of German universities.Material and method From june 2000 to january 2002 the 75 web based training programs of 57 providers,which can be contacted from the web pages of the radiological departments of german universities were evaluated in a prospective study.A medical student experienced in using the world wide web examined each training program three times in an interval of six months using the following criteria: availability of the web sites,target group,kind of training program,contents and structure and the technical solution. 51 of the 57 the homepages were fully available at each visit. 64 of the 75 web based training programs which could be connected from these sites were available at all three visitis.One program was only partially available at one spot check. 8 of the 75 programs were designed for physicians and medically trained personal, 23 were made for medical students and 44 addressed both target groups (partially more than once mentioned).The number of the presented cases ranged between one single and 3700. In 31 of 75 training programs links to other teaching files were found.A complete presentation of cases was presented by 48 of the 75 web sites.5 of the 75 web sites offered physiological images for comparison. In 20 training programs the pathological changes were optically marked in the x-ray images.A logical and didactical structure was found in 24 teaching files, 14 gave the possibility to check the learning results.No provider made use of the possibility to pass credits to the students or physicians acount with regard to official training programs. Multimedia techniques were used in 15 training programs.43 sites used data reduced preview images (thumbnails).The latest update of the site is mentioned in 55 of the 75 web sites. 19 of 57 providers had either no possibility of contact or did not answer to an e-mail. From the homepages

  4. An attempt to evaluate the risks associated with radiological terror

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Dantas, B.M.

    2014-01-01

    The evaluation of the risk of a terrorist attack has been made frequently by multiplying the probability of occurrence of a terrorist attempt by the probability of its success and a quantity which represents the consequences of a successful attack. In the case of a radiological attack the consequences will vary in case the action will be active or passive. Thirteen radionuclides were examined for their potential uses in credible threats or terrorist attacks based on their availability from laboratories and hospitals. Taking into account the dose conversion coefficients published by the International Atomic Energy Agency, those radionuclides with higher dose effectiveness for ingestion are the following: 210 Po; 226 Ra and 241 Am. Other radionuclides which can be used in threats and terror attacks, like 137 Cs for example have also been examined. The risks associated with the selected radionuclides have been tentatively ranked as high, medium, or low. The probability used to evaluate risks depends on the motivation of the terrorist and the capacity, which implies availability or the actual possibility of obtaining a particular radionuclide. On the other hand, whenever a list of radionuclides to be used in a malevolent action is available to a terrorist, the choice of the most adequate will depend also on the action to be undertaken. This work ranks risks associated with radiological terror based on physical, chemical, radio-toxicological and other relevant data on radionuclides, which were either already used in terror attacks, or were pointed out as adequate to be used in such malevolent actions. (author)

  5. Radiologic evaluation of intestinal obstruction in the neonates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hee; Kim, Dong Woo; Lee, Eun Suk; Kwon, Sun Young [Eul Ji General Hospital, Daejeon (Korea, Republic of); Lee, Sang Young [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of); Kang, Hye Jeong [Eul Ji General Hospital, Seoul (Korea, Republic of)

    1995-10-15

    The purpose of this study is to evaluate the radiologic findings of the intestinal obstruction in the neonate according to the causes and to determine the findings useful for the differential diagnosis. The materials consisted of 29 neonates with surgically proven gastrointestinal tract obstruction. We analyzed simple abdominal radiography and barium study comparing with the operative findings. The causes of intestinal obstruction were gastric atresia in 1 case, duodenal atresia in 3 cases, small bowel atresia in 11 cases (jejunal; 3 cases, ileal; 8 cases), colonic atresia in 2 cases, Hirschsprung's disease in 9 cases, ano-rectal anomaly in 6 cases, midgut volvulus in 2 cases, and Meckel's diverticulum in 1 case. Vomiting was noted in the all cases. The abdominal distension was not noted in the cases of gastric atresia, duodenal atresia, and proximal jejunal atresia. The meconium passage was noted in 2 cases of ileal atresia and 3 cases of Hirschsprung's disease. On barium study, site of obstruction was predicted accurately in gastric atresia, duodenal atresia, proximal jejunal atresia, and colonic atresia but it was not possible in distal jejunal atresia and ileal atresia. The microcolon was noted in 2 cases of jejunal atresia, 4 cases of ileal atresia, and 2 cases of colonic atresia. Out of 9 Hirschsprung's disease transition zones were seen on rectum or rectosigmoid junction in 7 cases and barium study was normal in 2 cases. In the diagnosis of neonatal intestinal obstruction, the basic radiologic studies such as simple abdominal radiography and gastrointestinal contrast study was useful for the differential diagnosis of the proximal bowel loop atresia colonic atresia, and midgut volvulus.

  6. Radiologic evaluation of intestinal obstruction in the neonates

    International Nuclear Information System (INIS)

    Kim, Jin Hee; Kim, Dong Woo; Lee, Eun Suk; Kwon, Sun Young; Lee, Sang Young; Kang, Hye Jeong

    1995-01-01

    The purpose of this study is to evaluate the radiologic findings of the intestinal obstruction in the neonate according to the causes and to determine the findings useful for the differential diagnosis. The materials consisted of 29 neonates with surgically proven gastrointestinal tract obstruction. We analyzed simple abdominal radiography and barium study comparing with the operative findings. The causes of intestinal obstruction were gastric atresia in 1 case, duodenal atresia in 3 cases, small bowel atresia in 11 cases (jejunal; 3 cases, ileal; 8 cases), colonic atresia in 2 cases, Hirschsprung's disease in 9 cases, ano-rectal anomaly in 6 cases, midgut volvulus in 2 cases, and Meckel's diverticulum in 1 case. Vomiting was noted in the all cases. The abdominal distension was not noted in the cases of gastric atresia, duodenal atresia, and proximal jejunal atresia. The meconium passage was noted in 2 cases of ileal atresia and 3 cases of Hirschsprung's disease. On barium study, site of obstruction was predicted accurately in gastric atresia, duodenal atresia, proximal jejunal atresia, and colonic atresia but it was not possible in distal jejunal atresia and ileal atresia. The microcolon was noted in 2 cases of jejunal atresia, 4 cases of ileal atresia, and 2 cases of colonic atresia. Out of 9 Hirschsprung's disease transition zones were seen on rectum or rectosigmoid junction in 7 cases and barium study was normal in 2 cases. In the diagnosis of neonatal intestinal obstruction, the basic radiologic studies such as simple abdominal radiography and gastrointestinal contrast study was useful for the differential diagnosis of the proximal bowel loop atresia colonic atresia, and midgut volvulus

  7. Evaluating variability and uncertainty in radiological impact assessment using SYMBIOSE

    International Nuclear Information System (INIS)

    Simon-Cornu, M.; Beaugelin-Seiller, K.; Boyer, P.; Calmon, P.; Garcia-Sanchez, L.; Mourlon, C.; Nicoulaud, V.; Sy, M.; Gonze, M.A.

    2015-01-01

    SYMBIOSE is a modelling platform that accounts for variability and uncertainty in radiological impact assessments, when simulating the environmental fate of radionuclides and assessing doses to human populations. The default database of SYMBIOSE is partly based on parameter values that are summarized within International Atomic Energy Agency (IAEA) documents. To characterize uncertainty on the transfer parameters, 331 Probability Distribution Functions (PDFs) were defined from the summary statistics provided within the IAEA documents (i.e. sample size, minimal and maximum values, arithmetic and geometric means, standard and geometric standard deviations) and are made available as spreadsheet files. The methods used to derive the PDFs without complete data sets, but merely the summary statistics, are presented. Then, a simple case-study illustrates the use of the database in a second-order Monte Carlo calculation, separating parametric uncertainty and inter-individual variability. - Highlights: • Parametric uncertainty in radioecology was derived from IAEA documents. • 331 Probability Distribution Functions were defined for transfer parameters. • Parametric uncertainty and inter-individual variability were propagated

  8. Evaluation of radiology personnel practice of Mazandaran University of Medical Sciences

    International Nuclear Information System (INIS)

    Rahimi, S.A.

    2007-01-01

    Complete text of publication follows. Background and purpose: Radiology department that provides images with proper quality plays a vital role in diagnosis of diseases. Good image is obtained by proper technical criteria and correct Positioning. Personnel practice of radiology department has a principal role on radiographs quality. This study was carried out to determine the radiology department personnel practice in university hospitals. Method and Material: Data collection was made using an observational check list. Its validity and reliability was determined previously. The sample size of which was thirty-nine persons. 29 items of practice related to technical and protect ional aspects at three working shifts were observed and recorded separately. Results: Results showed that most of the personnel were female (61.5%), over 40 years old (59%) and technicians (53.8%). On the whole, personnel's score percentages in technical field on three shifts of morning evening and night were 47.5%, 46.2%, and 45.9%, respectively which were less than them in protect ional field (60.3%, 56A% and 55.8%, respectively). Comparison of technical protection and total scores related to individual variables showed significant difference only in organizational grades (p<0.0001, p<0.05, p<0.0001, respectively) Le. The mean scores of radiological technologists holding BSc and associate degrees were more than those of technologists not holding university degrees. Conclusion: The quality of the personnel practice is not desirable; therefore continuing education programmers are needed for personnel. Protection against radiation exposure, availability of equipment and continuous evaluation of use of equipment can be effective in dose reduction in patients.

  9. Clinical correlation of radiological spinal stenosis after standardization for vertebral body size

    International Nuclear Information System (INIS)

    Athiviraham, A.; Yen, D.; Scott, C.; Soboleski, D.

    2007-01-01

    Aim: To determine the relationship between the degree of radiographic lumbar spinal stenosis, adjusted with an internal control for vertebral body size, and disability from lumbar stenosis. Materials and methods: one hundred and twenty-three consecutive patients with clinical and radiological confirmation of neural impingement secondary to lumbar stenosis were enrolled prospectively. Thecal sac anteroposterior (AP) diameter (TSD) and cross-sectional area (CSA), and vertebral body AP dimension (VBD) were determined. These parameters were then correlated with patients' symptoms using the modified Roland-Morris questionnaire (RMQ) disability score. Results: No statistically significant inverse correlation was found between the TSD and RMQ score (p = 0.433), between the CSA and RMQ score (p = 0.124), or between the TSD:VBD ratio and RMQ score (p = 0.109). There was a significant positive correlation between the CSA:VBD ratio and RMQ score (p = .036), and therefore, there was no statistical support for an inverse relationship between the two. There was a significant difference in mean RMQ scores when the patients were divided into those with CSA greater than or equal to 70 mm 2 and those less than 70 mm 2 , with T = -2.104 and p = 0.038. Conclusion: The degree of radiographic lumbar spinal stenosis, even with the use of an internal control of vertebral body size and standardized disability questionnaires, does not correlate with clinical symptoms. However, patients with more severe stenosis below a CSA critical threshold of 70 mm 2 , have significantly greater functional disability

  10. Common carotid artery thrombosis; Clinical and radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Yasuhiro; Yasuda, Takeshi; Hakusui, Shigetaka; Yanagi, Tsutomu (Nagoya Daini Red Cross Hospital (Japan)); Ito, Eiichi

    1994-02-01

    Common carotid artery thrombosis (CCAT) is not common. We studied 4 patients with CCAT to clarify the clinical and radiological features of this disorder. Case 1 had only episodes of TIA. Case 2 was diagnosed by chance as having CCAT at the time of admission due to cerebellar infarction. On the contrary, Cases 3 and 4 were admitted because of disturbance of consciousness and hemiparesis. Case 4 died soon after his stroke because of complications. We evaluated cases 1, 2 and 3 using head CT, head MRI, neck MRI, MR angiography, SPECT and cerebral angiography. Case 4, who was evaluated with head CT and cerebral angiography, was autopsied to confirm the occlusion of the common carotid artery. The clinical severity of CCAT varies from asymptomatic to severe, because each case differs in the time taken for complete occlusion of the common carotid artery; the development of collateral circulation; and hemodynamics of the brain. As for the collaterals their contribution is variable; for example, the thyrocervical and other arteries function as the bypass. We can diagnose CCAT easily and noninvasively using MR angiography and neck MRI based on disappearance of the flow void in the common carotid artery or internal carotid artery. On physical examination, it is important to detect faded pulsation of the superficial temporal artery that is ipsilateral to the occluded common carotid artery. (author).

  11. RADIOLOGICAL EVALUATION OF OBSTRUCTIVE JAUNDICE BY ULTRASOUND AND CT

    Directory of Open Access Journals (Sweden)

    Padmalatha

    2015-10-01

    Full Text Available INTRODUCTION: The goals of any radiologic procedure in obstructive Jaundice are to confirm the presence of bile duct obstruction, its location, its extent & the probable cause. It should also attempt to obtain a map of the biliary tree that will help the surgeon to det ermine the best approach to each individual case. OBJECTIVES: 1. To evaluate the role of Ultrasound and CT in patients presenting with clinical features of obstructive jaundice. 2. To evaluate the causes of obstructive jaundice by Ultrasound and CT. PATIENTS AND METHODS: The study was carried with 45 patients from January 2006 to September 2007 who were attending the surgical and Gastroenterology Departments, Govt. General Hospital, Kurnool, which is an attached hospital to Kurnool Medical College, Kurnool. O BSERVATIONS AND RESULTS: In our study, there is female predominance with male: female ratio 1: 1.6.Majority of patients are in age group of 41 - 50 years. Jaundice was the commonest presentation in all patients followed by pruritis in 72% and pain abdomen in 67% of patients. Ultrasound identified the benign cause of biliary obstruction in 79.1% cases and the malignant cause in 61.9% cases. CT identified the benign cause of biliary obstruction in 91.6% of patients and the malignant cause in 80.9% cases.

  12. Radiological evaluation of cartilage after microfracture treatment: A long-term follow-up study

    International Nuclear Information System (INIS)

    Von Keudell, A.; Atzwanger, J.; Forstner, R.; Resch, H.; Hoffelner, T.; Mayer, M.

    2012-01-01

    Introduction: Recent literature revealed good short-term results after microfracturing (MFX) of isolated focal cartilage defects in the knee joint. Study purpose was a long-term evaluation of patients who received MFX through a multimodal approach, correlating clinical scores and morphological pre- and postoperative MRI-scans. Materials and methods: Between 2000 and 2007 158 patients were treated with MFX for focal femoral or tibial defects at our department. Patients with instabilities, secondary surgical intervention, patellofemoral lesions, a plica mediopatellaris or more than one cartilage defect site and age >55 were excluded. 15 patients were included. Minimum postoperative follow-up (FU) was 18 months (18–78 m). Mean age at surgery was 45 years (27–54), mean FU-interval 48 months (18–78 m). Male to female ratio was 9:6. For clinical assessment the Knee Osteoarthritis Outcome Score (KOOS) and Lysholm Score were used, radiological evaluation was performed with radiographs and 3Tesla-MRI. Results: Clinical knee function was rated good to excellent in 1 patient, fair in 2 and poor in 10 patients. 2/15 patients received full knee replacement due to insufficient cartilage repair through MFX during FU period. Evaluation of pre- and postoperative MRI showed good cartilage repair tissue in 1 (7.7%), moderate repair in 2 (15.4%) and poor fill in 10 patients (76.9%). In these 10 patients the defect size increased. Average defect size preoperatively was 187 mm 2 (range 12–800 mm 2 ) and postoperatively 294 mm 2 (40–800 mm 2 ). The KOOS-Pain averaged 60 (39–94), KOOS-Symptoms 60.6 (21–100), KOOS-ADL 69 (21–91), KOOS-Sports 35.7 (5–60) and KOOS-QUL 37.2 (6–81). The average Lysholm Score was 73.9 (58–94). 10 patients showed a varus leg axis deviation (Ø 5.9°), 3 had a neutral alignment. The alignment correlated positively with KOOS and especially with the Lysholm Score. Conclusion: Our study demonstrated that MFX as a treatment option for cartilage

  13. Evaluation of Van Lake (Turkey) about radiological and hydrogeological risk

    International Nuclear Information System (INIS)

    Akyil, S.; Aytas, S.; Yusan, S.; Aslani, M. A. A.; Aycan, H. A.; Eral, M.; Tuerkoezue, D. A.; Isik, M. A.; Oelgen, M. K.

    2009-01-01

    Basins which are grow in the continent and not discharge to open sea are named as a close basin. Lead, uranium and thorium are high levels in respect to open basins. Lake of Van is a close basin. In the lake basins, rivers which are discharge basin are the most important source of the heavy metal concentration. In this study, surface water, coast and deep sediments of Van Lake and Inci Kefal (fish) were analyzed as a radiological and evaluated in terms of hydrogeological. Data was obtained for natural radioactivity concentration of this lake and evaluated using geostatistical methods in a geographical information system environment and fitted for isoradioactivity contour maps. The concentration and distribution of natural radionuclides in Van Lake were investigated with the aim of evaluating the environmental radioactivity. Sixty three coastal and deep sediments, 228 lake surface waters and 12 fish samples were taken in Van Lake over the time period 2005-2008 and the distribution pattern of the measured radionuclides was presented. The mean concentrations of gross alpha and beta, eU, eTh and K-40 activities in sediments were 207±96, 1046±60, 207±96, 70±29 and 399±231 Bq/kg, respectively. On the other hand, water samples from Van Lake had mean concentrations of 0.74±0.46 Bq/L for gross alpha activity concentration, 0.02±0.01 Bq/L for gross beta activity concentration, 0.06±0.04 Bq/L for gross radium isotopes, respectively. The mean gross alpha and beta, eU, eTh and K-40 activities in fish samples were 47±18, 470±12, 0.57±0.22, 0.022±0.006, 319±11 Bq/kg, respectively. An average annual effective dose equivalent (mSv/y) was calculated.

  14. Radiological data acquisition, investigation and evaluation of mining relics

    International Nuclear Information System (INIS)

    1992-01-01

    Within the scope of a Federal Project, the environmental radioactivity and the radon concentration in buildings caused by mining relics in the new Federal Lands of Germany are investigated. In the first phase of the project, about 8000 relics of former mining were identified by analysing existing documents, categorised, and recorded in a special data bank. Thereby, 'areas of suspicion' of 1500 km 2 spaciously defined in the beginning could be reduced to 'areas of investigation' of 250 km 2 now to be examined in close coordination with the land and district authorities by a programme gradually adapted to the radiological significance of the relics. Experience with site-specific measuring programmes have already been gained through three pilot projects at typical sites of former mining activities. Recommendations of the German Radiation Protection Commission serve for the evaluation of the results. By the measuring programme for radon in buildings of mining and geological predestined regions more than 25000 buildings of 210 communities have been investigated. The results confirm the expected prevailing influence of the geologic underground on the radon concentration. Extreme values are observed where direct connections additionally exist to mining relics in the ground. (orig./HP) With 11 figs. in annex [de

  15. Radioisotopic and Radiological Evaluation in Patient with Stress Fracture

    International Nuclear Information System (INIS)

    Ko, Kwang Seop; Kim, Jai Young; Kang, Sung Koo; Kim, So Yon; Lee, Gwon Jun

    1987-01-01

    The stress fracture is a disease caused by and abnormal stress to the normal bone with constant, repeated pull. Early detection of stress fracture plays an important role in treatment and prevention of its complication. Bone scintigraphy was performed to evaluate 18 patients with stress fracture of the lower extremities from May, 1985 to April, 1987, in the Department of Internal Medicine of National Police Hospital. The results were as follows: 1) Seventeen of the 18 cases showed positive bone scans at the initial study performed from 1 week to 5 months after the onset of symptom. 2) Ten of the 18 patients had findings of stress fracture at the initial X-ray film. Two out of 8 negative case revealed positive findings in the follow-up studies. 3) The bone scans in the 2 cases taken 5 months after the onset of symptom; the one showed only slightly increased radio uptake, the other showed no abnormal findings. In conclusion, bone scanning is a more sensitive indicator of early stress fracture than radiologic study, The healing phase is characterized by a gradual decline in radioactivity at the fracture site in concordance with subsidence of symptom.

  16. Radiological evaluation of the chronic venous stasis syndrome

    International Nuclear Information System (INIS)

    Train, J.S.; Schanzer, H.; Peirce, E.C. II; Dan, S.J.; Mitty, H.A.

    1987-01-01

    Chronic venous stasis is an extremely complex clinical syndrome of pain and changes in the skin that can involve the superficial, deep, and perforating veins. This syndrome is commonly referred to as the postphlebitic syndrome, implying that thrombophlebitis is its sole etiology. To test this hypothesis, the authors performed ascending venography on 51 limbs of patients with the chromic venous stasis syndrome and demonstrated that 32 had no radiological evidence of recent or old thrombophlebitis. Instead, they had normal-appearing veins, suggesting primary incompetence of the deep and/or perforating venous valves rather than thrombophlebitis as the etiology. Since various operations have recently been proposed to correct or bypass malfunctioning valves, precise demonstration of pathological change is required to choose the appropriate procedure and to evaluate results. Descending venograms were combined with the ascending studies in 42 limbs for this purpose. In addition to outlining the abnormalities responsible for chronic venous stasis syndrome in individual cases, interesting conclusions regarding the syndrome itself were reached

  17. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    Science.gov (United States)

    Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J

    2011-01-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  18. Radiological evaluation of chronic hemophilic arthropathy by the Pettersson score: Problems in correlation in adult patients

    Energy Technology Data Exchange (ETDEWEB)

    Hamel, J.; Pohlmann, H.; Schramm, W.

    1988-01-01

    This study deals with the distribution and extent of hemophilic arthropathy (HA) in 52 adult patients suffering from severe hemophilia A. A clinical and radiological evaluation was undertaken and the results were compared. The limitations of the currently used radiological scoring system are discussed. (orig.)

  19. Evaluation of radiological doses to the terrestrial plants around Trombay

    International Nuclear Information System (INIS)

    Ajay Kumar; Singhal, R.K.; Preetha, J.; Joshi, S.N.; Hegde, A.G.

    2005-01-01

    Existing policies for radiation protection do not provide explicit criteria for the protection of species other than humans, i.e. not for flora and fauna. Concern over this omission is now being widely expressed and moves are under way to evaluate the doses to terrestrial and aquatic biota. During the present work radiological doses (external and internal) to the terrestrial plants were evaluated by estimating the concentration of anthropogenic ( 137 Cs, 90 Sr) and natural radionuclides ( 238 U, 232 Th and 40 K) in the plant leaves and by measuring the external gamma radiation due to different radionuclide. The soil and vegetation sample were collected from fifteen sampling locations around the different locations at Trombay. The samples were processed as per IAEA (International Atomic Energy Agency) protocol for the estimation of naturally occurring and anthropogenic radionuclides in soil and terrestrial plants. The gamma emitting radionuclides were measured by high resolution gamma (HPGe) spectrometry system. Maximum exposure (external + internal) to the terrestrial plants was observed due to 232 Th while 238 U showed minimum exposure. The average value of radiation exposure to the terrestrial plants for 40 K, 137 Cs, 90 Sr, 238 U and 232 Th was 1555.2 ± 92.4, 691.2 ± 54.3, 2564.1 ± 534.9, 82.5 ±5.2, and 4419.6 ± 1165.5 μGy/y respectively. The radiation exposure (external + internal ) to the terrestrial plants due to all radionuclides was found within the permissible limits (i.e. 10 mGy/d) as per recommended by the United States, Department of Energy (DOE). (author)

  20. Current evaluation of the information about Radiological Protection in Internet

    International Nuclear Information System (INIS)

    Ruiz-Cruces, R.; Marco, M.; Villanueva, I.

    2003-01-01

    To analyze the current situation about the pedagogic information on radiological protection training which could be found in Internet. More than 756 web-pages have been visited in Internet about Radiological Protection in the nuclear and medical fields, providing information mainly focusing on information to the members of the public. In this search were used internet Searching Appliance (as Copernicus, Google and Scirus), using key words related with this subject (as Radiological Protection and Health Safety), getting the internet address of organizations, societies and investigation groups. Only a low percentage (less than 5 per cent) of these addresses content information on Radiological Protection for the members of the public, including information about the regulator Organizations, and which are the objectives for protection of the members of the public against ionization radiation (from the point of view of the use of the ionization radiation in the medical and nuclear field). This work attempts to propose the use of internet as a tool for informing the members of the public in matter of radiological protection, as first link in the chain of the training and education. (Author)

  1. Clinical and Radiological Evaluation of Children with Subacute Sclerosan Panencephalitis

    Directory of Open Access Journals (Sweden)

    Ahmet İrdem

    2004-01-01

    Full Text Available A total of 65 children with Subacute Sclerosing Panencephalitis (SSPE who admittedto our clinic between September 1998 and December 2002 were retrospectively evaluated interms of clinical and radiological findings.The most common symptoms and findings at admission were myoklonia (31 patients, 47%, behaveral changes (18 patients, 27.7 % and convulsion (8 patients, 12 %. There was atrauma history initiating symptoms in 14 patients (21.5 %. Neurological symptoms presentedsignificantly earlier in patients who had measles before 2 years of age compared to others(p0.05. The clinical stage of the patients at admission was determined based on Risk veHaddad classification. The most frequent stage was IIA (21 patients, 32.2%, IIC (17patients, 26.2% and IIB (16 patients, 24.6%. At the follow-up period, 46 (71% patients wasdepended to bed. The mean time interval between SSPE initiation age and bed dependencywas 4.68 ± 4.05 months (1-17 months.Of the 31 patients who underwent cranial magnetic rezonans imaging (MRI, 15patients (48.38% had pathological findings, the most frequent findings were cortical vesubcortical lesions. Of the 24 patients who underwent cranial tomographi, 22 (91.6% werenormal. Of the remaining two, one had atrophy and the other had increase in contrast. All ofthe patients underwent rutine EEG test. Fifty-four (83.1% of these had periodic complexhigh slow wave activity.The clinical findings and Electro Encephalographi results are important parameters inthe diagnosis of SSPE. Cranial tomographi is not useful in the diagnosis of SSPE. However,cranial MRI findings is pathologic only in the half of the patients.

  2. Quantitative Evaluation of Iranian Radiology Papers and Its Comparison with Selected Countries

    International Nuclear Information System (INIS)

    Ghafoori, Mahyar; Emami, Hasan; Sedaghat, Abdolrasoul; Ghiasi, Mohammad; Shakiba, Madjid; Alavi, Manijeh

    2014-01-01

    Recent technological developments in medicine, including modern radiology have promoted the impact of scientific researches on social life. The scientific outputs such as article and patents are products that show the scientists’ attempt to access these achievements. In the current study, we evaluate the current situation of Iranian scientists in the field of radiology and compare it with the selected countries in terms of scientific papers. For this purpose, we used scientometric tools to quantitatively assess the scientific papers in the field of radiology. Radiology papers were evaluated in the context of medical field audit using retrospective model. We used the related databases of biomedical sciences for extraction of articles related to radiology. In the next step, the situation of radiology scientific products of the country were determined with respect to the under study regional countries. Results of the current study showed a ratio of 0.19% for Iranian papers in PubMed database published in 2009. In addition, in 2009, Iranian papers constituted 0.29% of the Scopus scientific database. The proportion of Iranian papers in the understudy region was 7.6%. To diminish the gap between Iranian scientific radiology papers and other competitor countries in the region and achievement of document 2025 goals, multifold effort of the society of radiology is necessary

  3. Radiologic evaluation of facial injury; Avaliacao radiologica dos traumatismos faciais

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Ricardo Pires de; Volpato, Richard [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Servico de Diagnostico por Imagem]. E-mail: richard_volpato@uol.com.br; Nascimento, Lia Paula [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil)

    2003-03-01

    A detailed radiological investigation of the maxillofacial injuries is essential to achieve good treatment results. The images should identify every lesion and guide the treatment, thus improving esthetic and functional results. With the aim of simplifying the diagnostic task, the face may be seen as a five regions structure that may suffer a regional fracture or combined fractures involving the adjacent regions. These regions represent areas of focus for pre surgical planning and are as follows: nasal, orbital, zygomatic, maxillary, and mandibular. In order to understand the injury mechanisms and their consequences it is useful to know the supporting buttresses, which are divided in five sagittal planes, three horizontal planes and two coronal planes. We reviewed the cases of patients with facial trauma treated at Complexo Hospitalar Heliopolis, Sao Paulo, Brazil. A review of the relevant issues concerning radiological investigation of these injuries is presented. This study allowed standardization and ordering of the radiological investigation in patients with facial trauma. (author)

  4. Dose and risk evaluation to the thyroid gland in intra-oral dental radiology

    International Nuclear Information System (INIS)

    Souza, Edmilson M.; Lima, Marco A.F.; Kelecom, Alphonse; Correa, Samanda C.A.; Silva, Ademir X.; Brito, Alan

    2008-01-01

    Intra-oral technique is one of the most frequently used procedures of dental radiology, allowing the detection of a variety of dental anomalies such as caries, dental trauma and periodontal lesions, while exposing patients to relatively low doses of radiation. However, although the adverse effects of doses generated by dental radiology are essentially stochastic, a number of epidemiological studies have provided evidence of an increased risk of thyroid tumors for dental radiography. Many studies have measured doses of radiation for dental radiography, but only a few have estimated thyroid dose. Furthermore, most of the studies on dose evaluation in dental radiology are based on standardized calculation phantoms, which neglect the variance of the patient size or even sex. The purpose of this study is to use the Monte Carlo code MCNPX and the FAX (Female Adult voXel) and MAX (Male Adult voXel) phantoms to investigate how absorbed doses to the thyroid gland in intraoral dental examinations vary in female and male patients. The lifetime cancer incidence attributable to dental examinations were estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The phantoms study proved a useful trial for detecting the radiation dose to the thyroid gland and conclusively supported that the anatomy may be regarded as an influencing factor in radiation dose received during dental examination. Finally, the results have also confirmed that the association of the MCNPX code and the MAX and FAX phantoms is very useful in dosimetric studies on radiographic examinations of female and male patients. (author)

  5. Radiologic evaluation of coronary artery fistula in adult

    International Nuclear Information System (INIS)

    Je, Eun Kyoung; Kim, Yang Min; Choi, Ik Joon; Kim, Seong Bae; Lee, Jae Young; Han, Sang Wook; Cho, Sung Hwui; Park, Jae Hyung; Choi, Yonug Hi

    1997-01-01

    To evaluate the clinical and radiologic findings of coronary artery fistula (CAF) by reviwing adult patients in whom this condition had been diagnosed by coronary angiogram. We retrospectively analysed the clinical findings, chest X-rays and angiographic findings of 37 adult CAF patients treated at three institutes over a period of is 15 years. On coronary angiogram, the origin of CAF was found to be the left coronary artery (LCA) in 20 cases(54%), the right coronary artery (RCA) in five (14%), and both in 12(32%). By subdividing the coronary artery into four segments [RCA, left main coronary artery, left anterior descending artery(LAD), and left circumflex artery(LCX)], the origin of CAF (total 55 cases) was found to be the LAD in 23 cases(42%), the LCX in 12(22%), the left main coronary artery in three (5%), and the RCA in 17(31%). The draining site of CAF was the right heart [right atrium, right ventricle, and main pulmonary artery(MPA)] in 28 cases(75%) the left heart(left atrium and left ventricle) in 8(22%), and both in one (3%). The fistula drained to the cardiac chamber in 12 cases (33%), the MPA in 23(62%), and both in 2(5%). Among 55 cases, the total number of fistulas to the MPA was 35, and their origin was the RCA in nine instances (26%), and the left coronary artery in 26(74%). CAF to the MPA was classified into four types:Type I(single, tortuous and not dilated) was seen in six patients (17%), type II(single, tortuous and dilated) in three (9%), type III(multiple and fine plexus) in 21(60%), and type IV(multiple and dilated plexus)in five (14%). Eighteen cases (49%) were associated with the other cardiac disease. In these Korean adults, CAF originated most commonly from the LCA, especially from the LAD segment of this artery, and most frequently drained to the right cardic chamber, especially to the MPA. The morphology of the CAF to the MPA was mostly multiple and fine plexus. We suggest that to ensure the most suitable treatment, and for better

  6. Evaluation of long term radiological impact on population close to remediated uranium mill tailings storages

    International Nuclear Information System (INIS)

    Kerouanton, David; Delgove, Laure

    2008-01-01

    A methodology is elaborated in order to evaluate the long term radiological impact of remediated uranium mill tailings storage. Different scenarios are chosen and modelled to cover future evolution of the tailings storages. Radiological impact is evaluated for different population such as adults and children living in the immediate vicinity or directly on the storage, road workers or walkers on the storage. Equation and methods are detailed. (author)

  7. Computational evaluation of a pencil ionization chamber in a standard diagnostic radiology beam

    International Nuclear Information System (INIS)

    Mendonca, Dalila Souza Costa; Neves, Lucio Pereira; Perini, Ana Paula; Belinato, Walmir

    2016-01-01

    In this work a pencil ionization chamber was evaluated. This evaluation consisted in the determination of the influence of the ionization chamber components in its response. For this purpose, the Monte Carlo simulations and the spectrum of the standard diagnostic radiology beam (RQR5) were utilized. The results obtained, showed that the influence of the ionization chamber components presented no significant influence on the chamber response. Therefore, this ionization chamber is a good alternative for dosimetry in diagnostic radiology. (author)

  8. Common Pediatric Urological Disorders: Clinical and radiological evaluation

    OpenAIRE

    Robson, Wm. Lane M.; Leung, Alexander K.C.; Boag, Graham S.

    1991-01-01

    The clinical and radiological presentations of 12 pediatric urological disorders are described. The described disorders include pyelonephritis, vesicoureteral reflux, ureteropelvic obstruction, ureterovesical obstruction, ectopic ureterocele, posterior urethral valves, multicystic dysplastic kidney, polycystic kidney disease, ectopic kidney, staghorn calculi, urethral diverticulum, and urethral meatal stenosis.

  9. Radiological Evaluation of phosphate fertilizers used in Tunisia

    International Nuclear Information System (INIS)

    Jemli, Khaoula

    2010-01-01

    The need of control of natural radioactivity in the environment and the radiological impact of the use of chemical fertilizers has led us in this work to measure the natural radioactivity of the phosphate fertilizers in Tunisia. The distribution of various radionuclides during their manufacturing process of fertilizers is also part of this work.

  10. A radiologic study by CT scan of pineal size in cancer patients

    International Nuclear Information System (INIS)

    Tagliabue, M.; Macchi, I.; Salvini, E.; Lissoni, P.; Tancini, G.; Barni, S.; Crispino, S.

    1989-01-01

    Alterations in size of the pineal body and melatonin secretion have been observed in cancer patients. The present study was carried out to evaluate pineal dimension in a group of cancer patients and their relation to melatonin blood levels. The study included 70 oncologic patients. As controls, 41 patients with acute or chronic disease other than cancer entered the study. Melatonin serum levels were measured by radioimmunoassay on venous blood samples collected at 9:00 a.m. Pineal size was determined by brain CT scan, by considering the product of the two longest perpendicular diameters, multiplied by the thickness of the stratum. The volume of the pineal body was found to be enlarged in 12/70 (17%) cancer patients, and its mean value was significantly higher than that observed in controls. Melatonin levels were also significantly higher in oncologic patients than in controls. However, there was no correlation between melatonin levels and pineal size in cancer patients. Finally, cancer patients did not show a higher degree of pineal calcifications than controls. The clinical significance of pineal enlargement in cancer patients remains to be understood

  11. Objectives, Extent and Organization of Radiological and Environmental Protection in Relation to the Nature and Size of Nuclear Facilities

    International Nuclear Information System (INIS)

    Kathren, R.L.

    1979-01-01

    Radiological and environmental protection programs for nuclear facilities have similar goals and objectives, which are basically to protect people and the environment from adverse effects. To be effective, the programs must have organizational independence and a strong commitment from management. In return, the programs should ensure that the facility is operating in full compliance with law and good practice. The scope and elements of radiological environmental protection programs will vary according to facility type and size, with the larger and more complex facilities having a diversity of staff and functions. Examples of good and poor organization charts are given and discussed from the standpoint of program effectiveness along with a discussion of the role of the radiation protection committee. (author)

  12. Informatics in radiology: evaluation of an e-learning platform for teaching medical students competency in ordering radiologic examinations.

    LENUS (Irish Health Repository)

    Marshall, Nina L

    2011-09-01

    A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.

  13. Quantitative evaluation of risks for individuals in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Iinuma, T A; Tateno, Y; Hashizume, T [National Inst. of Radiological Sciences, Chiba (Japan)

    1980-05-01

    A method to estimate quantitatively risks of individual patients due to exposure to diagnostic radiation (carcinogenetic and genetic effects of radiation) was proposed on the basis of ICRP-26. Carcinogenetic effect of radiation was calculated by multiplying mean dose equivalent for each organ per each radiological examination by shortening of average life-expectancy which was calculated from incidence of fetal carcinoma of each organ, latent period of carcinoma, and incidence period of carcinoma. Genetic effect of radiation was calculated by multiplying mean dose equivalent for gonad per each radiological examination by incidence of genetically severe radiation damages due to parent's exposure and child expectancy rate. Three examples were shown on calculations of risks in the photofluorographic examinations of the stomach and chest, and mammography. The same method of calculation could be applied to the in-vivo nuclear medicine examinations. Further investigation was required to calculate the risks quantitatively for various types of diagnostic procedures using radiation.

  14. Radiation exposure and dose evaluation in intraoral dental radiology

    International Nuclear Information System (INIS)

    Poppe, B.; Looe, H. K.; Pfaffenberger, A.; Eenboom, F.; Chofor, N.; Sering, M.; Ruehmann, A.; Poplawski, A.; Willborn, K.

    2007-01-01

    In this study, dose area product measurements have been performed to propose diagnostic reference levels (DRLs) in intraoral dental radiology. Measurements were carried out at 60 X-ray units for all types of intraoral examinations performed in clinical routine. The third quartile values calculated range from 26.2 to 87.0 mGy cm 2 . The results showed that there exists a large difference between the patient exposures among different dental facilities. It was also observed that dentists working with faster film type or higher tube voltage are not always associated with lower exposure. The study demonstrated the necessity to have the DRLs laid out as guidelines in dental radiology. (authors)

  15. Quantitative evaluation of risks for individuals in diagnostic radiology

    International Nuclear Information System (INIS)

    Iinuma, T.A.; Tateno, Yukio; Hashizume, Tadashi

    1980-01-01

    A method to estimate quantitatively risks of individual patients due to exposure to diagnostic radiation (carcinogenetic and genetic effects of radiation) was proposed on the basis of ICRP-26. Carcinogenetic effect of radiation was calculated by multiplying mean dose equivalent for each organ per each radiological examination by shortening of average life-expectancy which was calculated from incidence of fetal carcinoma of each organ, latent period of carcinoma, and incidence period of carcinoma. Genetic effect of radiation was calculated by multiplying mean dose equivalent for gonad per each radiological examination by incidence of genetically severe radiation damages due to parent's exposure and child expectancy rate. Three examples were shown on calculations of risks in the photofluorographic examinations of the stomach and chest, and mammography. The same method of calculation could be applied to the in-vivo nuclear medicine examinations. Further investigation was required to calculate the risks quantitatively for various types of diagnostic procedures using radiation. (Tsunoda, M.)

  16. Clinical and radiological evaluation in vertebral artery dissections

    Directory of Open Access Journals (Sweden)

    Murat Çabalar

    2013-04-01

    Full Text Available In recent years, vertebral artery dissection (VAD is reported more frequently as a cause of young cerebrovascular accidents. It can occur spontaneously or following a neck manipulation and trauma. The patients were 3 females (mean age: 35±26 years and 7 males (mean age: 37.71±4.96 years. Only 2 patients described neck trauma. Cerebellar findings were prominent in all cases. On radiological investigation, vascular changes of vertebral arteries were detected bilaterally in 2 cases, right in 5 and left in 3 cases. All the cases were treated with anticoagulant therapy and cured but 1 with sequela. Prognosis of vertebral artery dissection is generally good by early diagnosis and treatment. In this article, we reported clinical and radiological properties of 10 vertebral artery dissection cases.

  17. Evaluation of the detector response function digital conventional radiology

    International Nuclear Information System (INIS)

    Arino Gil, A.; Hernandez Rodriguez, J.; Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J. C.

    2013-01-01

    The objective of this work is to obtain the response function that relates the air kerma at the entrance of the detector and pixel value, for a series of digital detectors of conventional Radiology model Optimus DigitalDiagnost Philips () and 6000 Definium General Electric. From the set of measurements is obtained a response function for each reference type of detector, and compared with those published in the literature for these teams. (Author)

  18. Evaluation system for the analysis of the radiological consequences (RASCAL)

    International Nuclear Information System (INIS)

    Miguel Martinez, M. J. de

    2011-01-01

    The code currently employed by the Spanish Nuclear power is the IRDAM (Interactive Rapid Dose Assessment Model). This code will now be replaced by the RASCAL (Radiological Assessment System for Consequence Analysis) version 4.0. This is a significant improvement in dose calculation for escapes to the atmosphere for radioactive emergencies. The main objective is to highlight the most significant changes introduced in the RASCAL when performing these dose estimates.

  19. Radiological evaluation of early gastric cancer: analysis of 104 cases

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; Kim, Jae Hyung; Han, Man Chung

    1987-01-01

    During the two year period from January 1985 to December 1986, 161 cases were confirmed as early gastric cancer by pathologic mapping at Seoul National University Hospital. Among them, the authors reviewed 104 cases of early gastric cancer for the evaluation of diagnostic value of double contrast upper gastrointestinal series. Early gastric cancer was most common in 5th and 6th decade (64%) and male to female ratio was 2:1. Double contrast upper GI series could detect 97 out of 104 cases (93%). Among them, 62 cases were diagnosed as early gastric cancer, 32 as advanced gastric cancer and 3 as benign lesion. Detection rate according to the size was 100% in lesion larger than 2cm and 87% in lesion smaller than 2cm. Predictability of early gastric cancer according to size was 66% in lesion smaller than 3cm and 43% in lesion larger than 3cm. Detection rate according to the location of the tumor was almost similar between gastric body (94%) and antrum (93%), however was very low in anterior wall lesion (70%). Predictability of early gastric cancer was 69% in gastric body lesion, 52% in gastric antral lesion and 44% in greater curvature lesion. Detection rate according to the type of macrospecimen was 100% in type I, III and IIc+III. Type IIb showed the lowest detection rate (75%). Predictability of early gastric cancer was high in type IIc (68%) and low in type I (20%)

  20. Evaluation of the contribution of radiological imaging to the final diagnosis in medical case reports

    International Nuclear Information System (INIS)

    Wiesinger, Isabel; Scharf, Gregor; Platz, Natascha; Dendl, Lena M.; Stroszczynski, Christian; Schreyer, Andreas G.; Pawlik, Michael T.

    2015-01-01

    To evaluate the clinical value and impact of radiological imaging in published medial case reports. We analysed 671 consecutively published case reports of a peer-reviewed medical journal for case reports. The general use of radiological imaging as well as the specific imaging modality used in each case (ultrasound, x-ray, fluoroscopy, CT, MRI) was documented, and most importantly the 'final problem solver', i.e. the diagnostic modality giving the final clue to the patient's diagnosis, was identified. In 511 of 671 (76.1 %) analysed case reports at least one radiological modality was used in the diagnostic cascade. In 28.6 % of all cases the final diagnosis was achieved by radiological imaging. All other cases were solved by the patient's history and physical examination (15.2 %), histology (12.4 %), and blood analysis (9.6 %). When radiology was the 'final problem solver', it was mainly CT (51.6 %) and MRI (30.6 %). In 52.2 % of the case reports the radiological image was included in the article. In case reports published in a prominent general medical journal radiological imaging is an important key player in the diagnostic process. In many cases, it is also the diagnostic tool which ultimately leads to determining the final diagnosis. (orig.)

  1. Evaluation of the contribution of radiological imaging to the final diagnosis in medical case reports

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Isabel; Scharf, Gregor; Platz, Natascha; Dendl, Lena M.; Stroszczynski, Christian; Schreyer, Andreas G. [University Hospital Regensburg, Institute of Radiology, Regensburg (Germany); Pawlik, Michael T. [Intensive Care and Emergency Medicine, Institute of Anaesthesiology, Regensburg (Germany)

    2015-05-01

    To evaluate the clinical value and impact of radiological imaging in published medial case reports. We analysed 671 consecutively published case reports of a peer-reviewed medical journal for case reports. The general use of radiological imaging as well as the specific imaging modality used in each case (ultrasound, x-ray, fluoroscopy, CT, MRI) was documented, and most importantly the 'final problem solver', i.e. the diagnostic modality giving the final clue to the patient's diagnosis, was identified. In 511 of 671 (76.1 %) analysed case reports at least one radiological modality was used in the diagnostic cascade. In 28.6 % of all cases the final diagnosis was achieved by radiological imaging. All other cases were solved by the patient's history and physical examination (15.2 %), histology (12.4 %), and blood analysis (9.6 %). When radiology was the 'final problem solver', it was mainly CT (51.6 %) and MRI (30.6 %). In 52.2 % of the case reports the radiological image was included in the article. In case reports published in a prominent general medical journal radiological imaging is an important key player in the diagnostic process. In many cases, it is also the diagnostic tool which ultimately leads to determining the final diagnosis. (orig.)

  2. Evaluation of use of e-Learning in undergraduate radiology education: a review.

    Science.gov (United States)

    Zafar, Saad; Safdar, Saima; Zafar, Aasma N

    2014-12-01

    The aim of this review is to investigate the evaluative outcomes present in the literature according to Kirkpatrick's learning model and to examine the nature and characteristics of the e-Learning interventions in radiology education at undergraduate level. Four databases (PubMed, MEDLINE, Embase, Eric) are searched for publications related to the application of e-Learning in undergraduate radiology education. The search strategy is a combination of e-Learning and Mesh and non Mesh radiology and undergraduate related terms. These search strategies are established in relation to experts of respective domains. The full text of thirty pertinent articles is reviewed. Author's country and study location data is extracted to identify the most active regions and year's are extracted to know the existing trend. Data regarding radiology subfields and undergraduate year of radiology education is extracted along with e-Learning technologies to identify the most prevalent or suitable technologies or tools with respect to radiology contents. Kirkpatricks learning evaluation model is used to categorize the evaluative outcomes reported in the identified studies. The results of this analysis reveal emergence of highly interactive games, audience response systems and designing of wide range of customized tools according to learner needs assessment in radiology education at undergraduate level. All these initiatives are leading toward highly interactive self directed learning environments to support the idea of life-long independent learners. Moreover, majority of the studies in literature regarding e-Learning in radiology at undergraduate level are based on participant satisfaction followed by participant results or outcomes either before or after an intervention or both. There was no research particularly demonstrating performance change in clinical practice or patient outcome as they may be difficult to measure in medical education. Thus clinical competences and performances are

  3. Evaluation of radiological findings of complete gastric erosions

    International Nuclear Information System (INIS)

    Jung, Hyun Sub; Choi, See Sung; Lim, Yeo Sub; Kim, Byung Chan; Chung, Young Sun; Kim, Chang Guhn; Won, Jong Jin

    1987-01-01

    The double-contrast upper gastrointestinal (UGI) examination is an effective means of clearly demonstrating complete gastric erosions. The main radiographic feature of the complete gastric erosion is a small barium fleck surrounded by a radiolucent halo in the gastric mucosa. From Jan. 1984 to Dec. 1986 a total of 48 cases of complete gastric erosions was diagnosed by double-contrast UGI examinations, and then 12 cases among them underwent endoscopy within 6 days of UGI examination. For evaluation of the relationship of the diameters of radiolucent halos to the central barium flecks, the radiographic findings were reviewed. 1. 1) The male to female ratio was 20:28. The age of patients ranged from 15 to 76 years, and the most common age group was 6th decade. 2) The clinical symptoms included epigastralgia (63%), indigestion, hunger pain, and vomiting. 2. Thirteen coexistent diseases were found in 11 patients (22.9%): gastric ulcer in 4 patients, duodenal ulcer in 3, gastric cancer in 3, liver cirrhosis in 2, and hepatoma in one. 3. The gastric antrum was involved in all cases. The gastric body was also involved in 8 case, and duodenal bulb in 2 cases. 4. In all cases there were multiple complete erosions. The number of the erosions were 2 to 10 in 83.4% of cases. The radiographic findings of 330 complete erosions in the 48 cases were analyzed. 1) The diameters of surrounding halos varied from 3 to 11mm, and the sized of the central barium flecks from 0(No central barium fleck) to 5mm. The shapes of central barium flecks were round in 70.6% of complete erosions. 2) In general, the small central barium flecks had small surrounding halos, and the large ones large halos (correlation coefficient r=0.97). But with the enlargement of central barium flecks, the ratios of the diameters of surrounding halos to the size of central barium flecks tended to decrease by degrees. It appears that in the formation of a surrounding mucosal elevation (radiolucent halo) of a complete

  4. Evaluation of radiological findings of complete gastric erosions

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hyun Sub; Choi, See Sung; Lim, Yeo Sub; Kim, Byung Chan; Chung, Young Sun; Kim, Chang Guhn; Won, Jong Jin [College of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    1987-06-15

    The double-contrast upper gastrointestinal (UGI) examination is an effective means of clearly demonstrating complete gastric erosions. The main radiographic feature of the complete gastric erosion is a small barium fleck surrounded by a radiolucent halo in the gastric mucosa. From Jan. 1984 to Dec. 1986 a total of 48 cases of complete gastric erosions was diagnosed by double-contrast UGI examinations, and then 12 cases among them underwent endoscopy within 6 days of UGI examination. For evaluation of the relationship of the diameters of radiolucent halos to the central barium flecks, the radiographic findings were reviewed. 1. 1) The male to female ratio was 20:28. The age of patients ranged from 15 to 76 years, and the most common age group was 6th decade. 2) The clinical symptoms included epigastralgia (63%), indigestion, hunger pain, and vomiting. 2. Thirteen coexistent diseases were found in 11 patients (22.9%): gastric ulcer in 4 patients, duodenal ulcer in 3, gastric cancer in 3, liver cirrhosis in 2, and hepatoma in one. 3. The gastric antrum was involved in all cases. The gastric body was also involved in 8 case, and duodenal bulb in 2 cases. 4. In all cases there were multiple complete erosions. The number of the erosions were 2 to 10 in 83.4% of cases. The radiographic findings of 330 complete erosions in the 48 cases were analyzed. 1) The diameters of surrounding halos varied from 3 to 11mm, and the sized of the central barium flecks from 0(No central barium fleck) to 5mm. The shapes of central barium flecks were round in 70.6% of complete erosions. 2) In general, the small central barium flecks had small surrounding halos, and the large ones large halos (correlation coefficient r=0.97). But with the enlargement of central barium flecks, the ratios of the diameters of surrounding halos to the size of central barium flecks tended to decrease by degrees. It appears that in the formation of a surrounding mucosal elevation (radiolucent halo) of a complete

  5. Evaluation of the lacrimal system by radiological methods

    International Nuclear Information System (INIS)

    Francisco, Fabiano Celli; Francisco, Vivian Frida Murta; Mendonca Junior, Adhemar Azevedo de; Carvalho, Antonio Carlos Pires; Fonseca, Lea Mirian Barbosa da; Gutfilen, Bianca; Francisco, Marina Celli

    2007-01-01

    The authors perform a revisional and iconographic study of the lacrimal system by means of radiological methods, namely, conventional radiography, linear tomography, computed tomography and magnetic resonance imaging. Image methods are essential to define diagnosis and therapy, considering that besides demonstrating alterations of the lacrimal system, they may indicate the patients with better prognosis associated with the surgical approach. Considering the lower cost, lower radiation dose, low rate of complications, and level of information that can be obtained dacryocystography by means of linear tomography is recommended as the initial investigation method. (author)

  6. Westinghouse corporate development of a decision software program for Radiological Evaluation Decision Input (REDI)

    International Nuclear Information System (INIS)

    Bush, T.S.

    1995-01-01

    In December 1992, the Department of Energy (DOE) implemented the DOE Radiological Control Manual (RCM). Westinghouse Idaho Nuclear Company, Inc. (WINCO) submitted an implementation plan showing how compliance with the manual would be achieved. This implementation plan was approved by DOE in November 1992. Although WINCO had already been working under a similar Westinghouse RCM, the DOE RCM brought some new and challenging requirements. One such requirement was that of having procedure writers and job planners create the radiological input in work control procedures. Until this time, that information was being provided by radiological engineering or a radiation safety representative. As a result of this requirement, Westinghouse developed the Radiological Evaluation Decision Input (REDI) program

  7. Westinghouse corporate development of a decision software program for Radiological Evaluation Decision Input (REDI)

    Energy Technology Data Exchange (ETDEWEB)

    Bush, T.S. [Westinghosue Idaho Nuclear Co., Inc., Idaho Falls, ID (United States)

    1995-03-01

    In December 1992, the Department of Energy (DOE) implemented the DOE Radiological Control Manual (RCM). Westinghouse Idaho Nuclear Company, Inc. (WINCO) submitted an implementation plan showing how compliance with the manual would be achieved. This implementation plan was approved by DOE in November 1992. Although WINCO had already been working under a similar Westinghouse RCM, the DOE RCM brought some new and challenging requirements. One such requirement was that of having procedure writers and job planners create the radiological input in work control procedures. Until this time, that information was being provided by radiological engineering or a radiation safety representative. As a result of this requirement, Westinghouse developed the Radiological Evaluation Decision Input (REDI) program.

  8. Organ doses in interventional radiology procedures: Evaluation of software

    International Nuclear Information System (INIS)

    Tort, I.; Ruiz-Cruces, R.; Perez-Martinez, M.; Carrera, F.; Ojeda, C.; Diez de los Rios, A.

    2001-01-01

    Interventional Radiology (IR) procedures require large fluoroscopy times and important number of radiological images, so the levels of radiation to patient are high, which leads us to calculate the organ doses. The objective of this work is to estimate and make a comparison of the results given by the different software that we have to do the calculation of organ doses in complex procedures of IR. To do this, 28 patients have been selected, distributed in the 3 procedures with highest doses. The determination of organ doses and effective doses has been made using the projections utilized and different software based on Monte Carlo Methods: Eff-dose, PCXMC and Diasoft. We have obtained very high dispersion in the average organ dose between the 3 programs. In many cases, it is higher than 25% and in some particular cases, it is greater than 100%. Dispersion obtained in effective doses is not so high, being under 20% in all cases. This shows that a better solution is needed to solve the problem of the organ doses calculation; a more accurate method is necessary that brings us to a trustworthy approach to reality, and, at the moment, that we do not dispose of it. (author)

  9. Critical evaluation of German regulatory specifications for calculating radiological exposure

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudia; Walther, Clemens [Hannover Univ. (Germany). Inst. of Radioecology; Smeddinck, Ulrich [Technische Univ. Braunschweig (Germany). Inst. of Law

    2015-07-01

    The assessment of radiological exposure of the public is an issue at the interface between scientific findings, juridical standard setting and political decision. The present work revisits the German regulatory specifications for calculating radiological exposure, like the already existing calculation model General Administrative Provision (AVV) for planning and monitoring nuclear facilities. We address the calculation models for the recent risk assessment regarding the final disposal of radioactive waste in Germany. To do so, a two-pronged approach is pursued. One part deals with radiological examinations of the groundwater-soil-transfer path of radionuclides into the biosphere. Processes at the so-called geosphere-biosphere-interface are examined, especially migration of I-129 in the unsaturated zone. This is necessary, since the German General Administrative Provision does not consider radionuclide transport via groundwater from an underground disposal facility yet. Especially data with regard to processes in the vadose zone are scarce. Therefore, using I-125 as a tracer, immobilization and mobilization of iodine is investigated in two reference soils from the German Federal Environment Agency. The second part of this study examines how scientific findings but also measures and activities of stakeholders and concerned parties influence juridical standard setting, which is necessary for risk management. Risk assessment, which is a scientific task, includes identification and investigation of relevant sources of radiation, possible pathways to humans, and maximum extent and duration of exposure based on dose-response functions. Risk characterization identifies probability and severity of health effects. These findings have to be communicated to authorities, who have to deal with the risk management. Risk management includes, for instance, taking into account acceptability of the risk, actions to reduce, mitigate, substitute or monitor the hazard, the setting of

  10. The clinical and radiological evaluation of pyogenic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Jun; Kim, Kyung Joo; Yoo, Jung Keun; Kim, Young Chul; Hur, Don [Chosun University College of Medicine, Gwangju (Korea, Republic of)

    1984-12-15

    Pyogenic arthritis remain a difficult problem, despite the availability of a wide range of powerful modern antibiotics. Early and correct diagnosis is imperative to assure the prompt initiation of an effective therapeutic regimen and the prevent of late sequela. Careful clinical, laboratory and roentgenological analysis are fundamental to early and precise diagnosis. Therefore, plain roentgenogram should not be overlooked. A radiological and clinical observation was made in 51 cases of pyogenic arthritis admitted to Chosun University Hospital during the period from January 1976 to December 1983 and following results were obtained. 1. Among the 51 cases, 36 cases (70.6%) were male and 15 cases (29.4%) were females. The most prevalent age was 5 to 9 (27.6%). 2. Symptom duration less than 5 days was in 21 cases (41.2%) and more than 31 days was in 6 cases (11.7%). 3. The most common symptom on admission was pain around the involved joint and others are limitation of motion, swelling, tenderness, fever, local heating and erythema. 4. The underlying causes were composed of unknown in 21 cases (41.2%), trauma in 18 cases (35.3%), infections focus in 8 cases (15.7%) and iatrogenic reason 4 cases (7.8%). 5. The most commonly affected joint was hip joint (45.1%). The other affected sites in order of frequency were knee, ankle, shoulder, S-I and elbow joint. In infants and children, hip and knee joint are commonly affected: in adults, knee joint is most is most commonly affected. 6. In laboratory findings, the number of W.B.C and E.S.R were increased in 56.9%. Symptom duration more than 31 days in 5 cases were increased E.S.R only. Causative microorganism was isolated in 31 cases: the most common microorganism was Staphylococcus aureus in 22 cases. Others are B-hemolytics Stretoocccus, Enterobacteriaceae species and Pseudomonas aeruginosa. 7. In 26 cases (50.9%) of the patients, roentgenographic findings was negative. The most common radiological findings was soft tissue

  11. The clinical and radiological evaluation of pyogenic arthritis

    International Nuclear Information System (INIS)

    Cho, Young Jun; Kim, Kyung Joo; Yoo, Jung Keun; Kim, Young Chul; Hur, Don

    1984-01-01

    Pyogenic arthritis remain a difficult problem, despite the availability of a wide range of powerful modern antibiotics. Early and correct diagnosis is imperative to assure the prompt initiation of an effective therapeutic regimen and the prevent of late sequela. Careful clinical, laboratory and roentgenological analysis are fundamental to early and precise diagnosis. Therefore, plain roentgenogram should not be overlooked. A radiological and clinical observation was made in 51 cases of pyogenic arthritis admitted to Chosun University Hospital during the period from January 1976 to December 1983 and following results were obtained. 1. Among the 51 cases, 36 cases (70.6%) were male and 15 cases (29.4%) were females. The most prevalent age was 5 to 9 (27.6%). 2. Symptom duration less than 5 days was in 21 cases (41.2%) and more than 31 days was in 6 cases (11.7%). 3. The most common symptom on admission was pain around the involved joint and others are limitation of motion, swelling, tenderness, fever, local heating and erythema. 4. The underlying causes were composed of unknown in 21 cases (41.2%), trauma in 18 cases (35.3%), infections focus in 8 cases (15.7%) and iatrogenic reason 4 cases (7.8%). 5. The most commonly affected joint was hip joint (45.1%). The other affected sites in order of frequency were knee, ankle, shoulder, S-I and elbow joint. In infants and children, hip and knee joint are commonly affected: in adults, knee joint is most is most commonly affected. 6. In laboratory findings, the number of W.B.C and E.S.R were increased in 56.9%. Symptom duration more than 31 days in 5 cases were increased E.S.R only. Causative microorganism was isolated in 31 cases: the most common microorganism was Staphylococcus aureus in 22 cases. Others are B-hemolytics Stretoocccus, Enterobacteriaceae species and Pseudomonas aeruginosa. 7. In 26 cases (50.9%) of the patients, roentgenographic findings was negative. The most common radiological findings was soft tissue

  12. The evaluation of radiological and clinical findings of bronchiectasis

    International Nuclear Information System (INIS)

    Yoo, Jung Keun; Kang, Sung Ihn; Kim, Kil Jung; Ko, Seung Sook; Kim, Young Sook; Kim, Young Chul

    1985-01-01

    Bronchiectasis means a permanent abnormal dilatation off one or more large bronchi owing to destruction of the elastic and muscular components of the bronchial wall. Radiological study is the most important and mandatory procedure. Especially bronchography is essential for the definitive diagnosis of bronchiectasis and for the precise delineation of the type and extent of the disease. The radiological and clinical findings of 48 cases of bronchiectasis diagnosed by bronchography and treated at Chosun University Hospital during the 5 years from January 1980 to December 1984 were analyzed retrospectively. The results were as follows; 1. Among the 48 cases, 34 cases (70.8%) were male and 14 cases (29.2%) were female. Peak incidence was in second decade. 2. Chronic cough productive sputum and hemoptysis are main symptoms and others are chest pain, dyspnea and recurrent bouts of pneumonia. The most common physical sign is persistent moist rales over the involved area in 23 cases (47.9%). Others are no sign in 17 cases (35.4%), wheezing in 11 cases (22.9%) and digit clubbing in 3 cases (6.3%). 3. The presumed causes were composed of not known in 30 cases (62.5%)> and complications of measles in 7 cases (14.6%), pertussis in 5 cases (10.4%) and pneumonia in 4 cases (8.3%). Two cases were Kartagener's syndrome and unilateral hyperlucent lung. 4. Plain chest common radiological findings was accentuation of lung marking in 36 cases (85.7%), the others are include in order of frequency; pneumonic infiltration, linear radiolucencies, cystic radiolucencies, decreased affected lung volume, air-fluid, level and pleural thickening. 5. Bilateral bronchiectasis was demonstrated in 11 cases (22.9%) and the disease was much more often involved left lung than right. The most commonly involved lobe is left lower lobe, and the most common site of involvement was the posterior basal segment of the lower lobe. The type of bronchiectasis is cylindrical in 22 cases (45.8%), varicose in 11

  13. Evaluation of management of communication in the actions of preparedness and response to nuclear and radiological emergencies

    Energy Technology Data Exchange (ETDEWEB)

    Mello Filho, Mauro Otto de Cavalcanti; Beserra, Marcela Tatiana Fernandes, E-mail: maurootto@cefet-rj.br, E-mail: maurootto@gmail.com, E-mail: mbeserra@cefet-rj.br [Centro Federal de Educacao Celso Sucknow da Fonseca (CEFET-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica Vergara, E-mail: mwasserman@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Julio Cesar de Faria Alvim, E-mail: geowass@vm.uff.br [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2013-07-01

    The use of practices involving the use of ionizing radiation in diverse areas of knowledge increases every day. This growth warning about the increased probability of accidents, radiological and nuclear emergencies, with possible consequences for the public, workers and the environment. Within this scenario, it is clear that studies and reassessments of the emergency response actions, receive proposals for continuous improvement. The achievement of the objectives of the response must be sustained by tactical, operation and logistics optimized processes. The articulation through communication between the teams involved in the response must be adaptable to each accident or emergency, respecting its size. The objectives of this study is to perform an assessment on the management of communication in the actions of Preparedness and Response to Nuclear and Radiological Emergencies. This assessment is supported by best practices of the Incident Command System (ICS) and the Institute of Project Management (Project Management Institute-PMI). For this purpose, based on models referred were established performance indicators supported by the BSC (Balanced Scorecard). These indicators allowed to evaluate more objectively the performance of the communication processes associated with each phase of the response. The study resulted in the proposed model documents aiming to assist planning of communications exercises in preparation and response actions, supported and adapted the best practices of PMI. These methodologies were evaluated by real cases selected from radiological and nuclear emergencies published by the International Atomic Energy Agency (IAEA). (author)

  14. Evaluation of management of communication in the actions of preparedness and response to nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Mello Filho, Mauro Otto de Cavalcanti; Beserra, Marcela Tatiana Fernandes; Wasserman, Maria Angelica Vergara; Wasserman, Julio Cesar de Faria Alvim

    2013-01-01

    The use of practices involving the use of ionizing radiation in diverse areas of knowledge increases every day. This growth warning about the increased probability of accidents, radiological and nuclear emergencies, with possible consequences for the public, workers and the environment. Within this scenario, it is clear that studies and reassessments of the emergency response actions, receive proposals for continuous improvement. The achievement of the objectives of the response must be sustained by tactical, operation and logistics optimized processes. The articulation through communication between the teams involved in the response must be adaptable to each accident or emergency, respecting its size. The objectives of this study is to perform an assessment on the management of communication in the actions of Preparedness and Response to Nuclear and Radiological Emergencies. This assessment is supported by best practices of the Incident Command System (ICS) and the Institute of Project Management (Project Management Institute-PMI). For this purpose, based on models referred were established performance indicators supported by the BSC (Balanced Scorecard). These indicators allowed to evaluate more objectively the performance of the communication processes associated with each phase of the response. The study resulted in the proposed model documents aiming to assist planning of communications exercises in preparation and response actions, supported and adapted the best practices of PMI. These methodologies were evaluated by real cases selected from radiological and nuclear emergencies published by the International Atomic Energy Agency (IAEA). (author)

  15. Experimental measurement of radiological penumbra associated with intermediate energy x-rays (1 MV) and small radiosurgery field sizes

    International Nuclear Information System (INIS)

    Keller, Brian M.; Beachey, David J.; Pignol, Jean-Philippe

    2007-01-01

    Stereotactic radiosurgery is used to treat intracranial lesions with a high degree of accuracy. At the present time, x-ray energies at or above Co-60 gamma rays are used. Previous Monte Carlo simulations have demonstrated that intermediate energy x-ray photons or IEPs (defined to be photons in the energy range of 0.2-1.2 MeV), combined with small field sizes, produce a reduced radiological penumbra leading to a sharper dose gradient, improved dose homogeneity and sparing of critical anatomy adjacent to the target volume. This hypothesis is based on the fact that, for small x-ray fields, a dose outside the treatment volume is dictated mainly by the range of electrons set into motion by x-ray photons. The purpose of this work is: (1) to produce intermediate energy x rays using a detuned medical linear accelerator (2) to characterize the energy of this beam (3) to measure the radiological penumbra for IEPs and small fields to compare with that produced by 6 MV x rays or Co-60, and (4) to compare these experimental measurements with Monte Carlo computer simulations. The maximum photon energy of our IEP x-ray spectrum was measured to be 1.2 MeV. Gafchromic EBT films (ISP Technologies, Wayne, NJ) were irradiated and read using a novel digital microscopy imaging system with high spatial resolution. Under identical irradiation conditions the measured radiological penumbra widths (80%-20% distance), for field sizes ranging from 0.3x0.3 to 4.0x4.0 cm 2 , varied from 0.3-0.77 mm (1.2 MV) and from 1.1-2.1 mm (6 MV). Even more dramatic were the differences found when comparing the 90%-10% or the 95%-5% widths, which are in fact more significant in radiotherapy. Monte Carlo simulations agreed well with the experimental findings. The reduction in radiological penumbra could be substantial for specific clinical situations such as in the treatment of an ocular melanoma abutting the macula or for the treatment of functional disorders such as trigeminal neuralgia (a nonlethal

  16. Plutonium Immobilization Bagless Transfer Can Size Evaluation

    International Nuclear Information System (INIS)

    Kriikku, E.; Stokes, M.; Rogers, L.; Ward, C.

    1998-02-01

    This report identifies and documents the most appropriate bagless transfer can size to support Plutonium Immobilization Can Loading operations. Also, this report considers can diameter, can wall thickness, and can length

  17. Pulmonary nodule size evaluation with chest tomosynthesis.

    Science.gov (United States)

    Johnsson, Åse A; Fagman, Erika; Vikgren, Jenny; Fisichella, Valeria A; Boijsen, Marianne; Flinck, Agneta; Kheddache, Susanne; Svalkvist, Angelica; Båth, Magnus

    2012-10-01

    To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably. © RSNA, 2012.

  18. Radiological evaluation of tumor response in oncological studies (tumor response evaluation)

    International Nuclear Information System (INIS)

    Gebauer, B.; Riess, H.

    2011-01-01

    Purpose: Radiological-morphological response evaluation plays a major role in oncological therapy and studies for approval. Specific criteria have been developed for some tumor entities and chemotherapeutics. Application, limitations and definitions of the most frequently used criteria for tumor response evaluation will be presented. Materials and Methods: Review based on a selective literature research. Results: In clinical oncological therapy studies, WHO and RECIST are the most frequently used criteria to evaluate morphological therapy response. RECIST criteria have been modified recently, especially with respect to the evaluation of lymph nodes, and were published as RECIST 1.1 in 2009. All criteria were originally developed and defined to review clinical multicenter trials for approval. Using these criteria in a clinical situation, certain limitations have to be considered. To evaluate response, a baseline scan before therapy start is mandatory. Special tumor response criteria have been defined for some certain tumor entities. Oncologists and radiologists should define in advance which criteria are used before starting therapy. Conclusion: The use of defined criteria is very important in oncology response evaluation. In-depth knowledge of the criteria and their limits is required for correct usage. (orig.)

  19. Evaluation of the radiological situation of the remedied areas - 30 years after the radiological accident with Cesium-137

    International Nuclear Information System (INIS)

    Correa, R. da S.; Santos, E.E. dos; Barbosa, R.C.; Borges, A.F. de Almeida; Costa, H.F.; Pimenta, L.

    2017-01-01

    In September 1987, the radiation accident resulting from the removal and dismantling of a sealed source containing Cesium-137 chloride happened in Goiânia, GO, Brazil. Due to its high solubility and the weather conditions of the time, there were dispersion in the environment around seven main concentrations, located in the central region. This study aimed to present the evaluation of the radiological situation of the remedied areas - 30 years after the radiation accident with cesium-137. The three main focuses were studied, being the plot of land at the 57 street, Scrap Metal I and II. Radiometric surveys were performed using a SPP2 detector, 10 cm from the floor to evaluate the integrity of the concrete and 1 m from the soil, using the IDENTIFIDER detector model NG + , to compare with the values of background radiation. A 2 x 2m pre-fixed sampling loop was used. In the plot of land at the 57 street, measurements were made at 154 points, at 10 cm from the floor, at a mean of 150 ± 121 cps, while at 1 m from the soil, the average was 0.19 ± 0.10 μSv / h. In the Scrap Metal I were 262 measurements and the average at 10 cm of the floor was 147 ± 113 cps and the 1 meter of the soil was of 0.18 ± 0.12 μSv / h. In Scrap Metal II the average of the 66 measurements carried out at 10 cm was 117 ± 58 cps and at 1 meter it was 0.13 ± 0.03 μSv / h. Currently the radiological situation of the lots, are below the limits established by the norms of CNEN

  20. Evaluation of use of e-Learning in undergraduate radiology education: A review

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, Saad, E-mail: saad.zafar@riphah.edu.pk [Riphah International University, Islamabad (Pakistan); Safdar, Saima, E-mail: saima.safdar@riphah.edu.pk [Riphah International University, Islamabad (Pakistan); Zafar, Aasma N., E-mail: aasmarad@gmail.com [Radiology Department, Senior Registrar Shifa College of Medicine and Assistant Consultant Shifa International Hospital, Islamabad (Pakistan)

    2014-12-15

    Highlights: • We have systematically reviewed the literature on use of e-Learning in Radiology at the undergraduate level. • Kirkpatrick's Learning Model is used to evaluate the learning outcomes of the reported studies. • There is an increase in positive response for learning management systems used in blended learning environments. • There are wide range of technologies being used for e-Learning including use of audio response system and customized PAC solutions. • There is a clear trend toward highly interactive, self directed learning environment to support the concept of life long independent learners. - Abstract: Purpose: The aim of this review is to investigate the evaluative outcomes present in the literature according to Kirkpatrick's learning model and to examine the nature and characteristics of the e-Learning interventions in radiology education at undergraduate level. Materials and methods: Four databases (PubMed, MEDLINE, Embase, Eric) are searched for publications related to the application of e-Learning in undergraduate radiology education. The search strategy is a combination of e-Learning and Mesh and non Mesh radiology and undergraduate related terms. These search strategies are established in relation to experts of respective domains. The full text of thirty pertinent articles is reviewed. Author's country and study location data is extracted to identify the most active regions and year's are extracted to know the existing trend. Data regarding radiology subfields and undergraduate year of radiology education is extracted along with e-Learning technologies to identify the most prevalent or suitable technologies or tools with respect to radiology contents. Kirkpatricks learning evaluation model is used to categorize the evaluative outcomes reported in the identified studies. Results: The results of this analysis reveal emergence of highly interactive games, audience response systems and designing of wide range of

  1. Evaluation of use of e-Learning in undergraduate radiology education: A review

    International Nuclear Information System (INIS)

    Zafar, Saad; Safdar, Saima; Zafar, Aasma N.

    2014-01-01

    Highlights: • We have systematically reviewed the literature on use of e-Learning in Radiology at the undergraduate level. • Kirkpatrick's Learning Model is used to evaluate the learning outcomes of the reported studies. • There is an increase in positive response for learning management systems used in blended learning environments. • There are wide range of technologies being used for e-Learning including use of audio response system and customized PAC solutions. • There is a clear trend toward highly interactive, self directed learning environment to support the concept of life long independent learners. - Abstract: Purpose: The aim of this review is to investigate the evaluative outcomes present in the literature according to Kirkpatrick's learning model and to examine the nature and characteristics of the e-Learning interventions in radiology education at undergraduate level. Materials and methods: Four databases (PubMed, MEDLINE, Embase, Eric) are searched for publications related to the application of e-Learning in undergraduate radiology education. The search strategy is a combination of e-Learning and Mesh and non Mesh radiology and undergraduate related terms. These search strategies are established in relation to experts of respective domains. The full text of thirty pertinent articles is reviewed. Author's country and study location data is extracted to identify the most active regions and year's are extracted to know the existing trend. Data regarding radiology subfields and undergraduate year of radiology education is extracted along with e-Learning technologies to identify the most prevalent or suitable technologies or tools with respect to radiology contents. Kirkpatricks learning evaluation model is used to categorize the evaluative outcomes reported in the identified studies. Results: The results of this analysis reveal emergence of highly interactive games, audience response systems and designing of wide range of

  2. Bluish granites from Extremadura (Spain): a radiological evaluation.

    Science.gov (United States)

    Pereira, Dolores; Neves, Luís.; Peinado, Mercedes; Pereira, Alcides; Rodríguez, Leticia; António Blanco, José

    2010-05-01

    We have found in the area of Trujillo (Extremadura, Spain) a variety of striking bluish granites, outcropping within the Plasenzuela pluton. They are all quarried under different names and are characterized by leucocratic minerals such as quartz, feldspar (both potassium and plagioclase), sometimes giving a fenocrystic texture and muscovite, with some biotite. As accessory phases, idiomorphic tourmaline is found. Recently a bluish phosphate distributed in the whole rock was detected, included within most mineral phases and fillings from stressed structures that are cutting the rock. We attribute the bluish color of the granites to this phosphate. Although biotite is almost always transformed to chlorite, the rock gives an excellent response to be polished. Physico-mechanical properties make this bluish granite a perfect option for most applications. Absorption coefficient is rather low and alteration by thermal changes has not been observed. A secondary facies with yellow colour also occurs, spatially close to the topographic surface, and probably represents an alteration product of the original granite. This facies is also commercialized as ornamental stone. A radiological survey was carried out in the field, using a gamma ray spectrometer. The radiological background is quite homogeneous in the pluton, without significant differences between gamma ray fluxes of both facies (altered and non altered). The average contents of U, Th and K2O determined in situ with the spectrometer are 7.4 ppm, 0.8 ppm and 3.67%, respectively (n=15). Using U as a Ra proxy, the I index of the EU technical document 112 can be determined, and results in a value of 0.64 for the referred composition. This implies that the rock can be used without any restrictions for building purposes. However, a marked difference was observed in radon exhalation tests carried out in laboratorial facilities. The dominant blue variety shows radon exhalation rates comprised between 0.02 and 0.04 Bq.kg-1.h-1

  3. Interim radiological safety standards and evaluation procedures for subseabed high-level waste disposal

    International Nuclear Information System (INIS)

    Klett, R.D.

    1997-06-01

    The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory agencies if subseabed disposal is implemented. 56 refs., 29 figs., 15 tabs

  4. Temporomandibular joint assessment in patients with articular disc displacement by way of computed tomography - radiological parameters of shape, size and location of mandibular heads

    Directory of Open Access Journals (Sweden)

    Szabelska Anna

    2015-09-01

    Full Text Available Conventional and modern methods of radiological imaging are often used in the diagnosis of temporomandibular joint disorders, and the CT technique is particularly characterized by an excellent visualization of bony structures. The aim of the study was to show the importance and role of CT in the evaluation of TMJ bone structures in both patients with articular disc displacement and in a group of healthy subjects. Both study groups were assessed with the use of the transverse plane. Herein, multi-slice spiral computed tomography was performed in 47 subjects. These individuals were qualified for CT by way of magnetic resonance imaging, due to their being diagnosed with a displacement of their temporomandibular joint disc. The product of our study is presented as a set of tables. These are comparisons of radiological parameters based on the shape, size and location of the mandibular head, in the examined patients, in a control group, and with regard to sex. The results of our work indicate that CT can be successfully used in the imaging of TMJ bone structures, specifically, the condylar process of the mandibular head and the joint socket. However, statistically significant differences of the utilized parameters between patients with articular disc displacement and controls, warrant further analysis of this issue.

  5. A radiologic evaluation of obstructive jaundice using percutaneous transhepatic cholangiography

    International Nuclear Information System (INIS)

    Schim, G. T.; Kim, T. H.; Zeon, S. K.; Ra, W. Y.

    1980-01-01

    Percutaneous transhepatic cholangiography (P.T.C.) is a most valuable procedure in differentiation of obstructive jaundice, whether benign (chiefly stone) or malignant condition. Authors present the clinical and P.T.C. findings of 30 cases of obstructive jaundice which were experienced from December 1975 to May 1977, at Department of Radiology, Kyung Pook National University Hospital. The summarized results were as follows. 1. The incidence of malignancy beyond the age of 40 was high compared with stone, which revealed relatively equal age distribution. 2. The stone showed as concave cupping in all cases (11 cases), but the malignancy showed as nipple formation (10 cases) and irregular narrowings (9 cases). 3. The dilation of the intrahepatic bile duct appeared 10 cases on malignancy among 19 cases of malignancy (52.6%) and 4 caes on stone which were multiple intrahepatic or common hepatic duct stones. 4. The dilation of the justproximal bile duct was severe on malignancy compared with stone. 5. The mean bilirubin level was high on malignancy (12.8 mg-%) compared with stone (10.3 mg-%).

  6. Radiological evaluation of tuberculous spondylitis with computed tomography

    International Nuclear Information System (INIS)

    Lim, Seung Soo; Kim, Chung Hyun; Cho, June Sik; Rhee, Byung Chull

    1986-01-01

    Spinal tuberculosis is curable disease, and early diagnosis is mandatory for early treatment. We reviewed conventional radiographers and computed tomograms (CT) from Histopathologically confirmed 30 cases of spinal tuberculosis, and compared these findings with radiologic findings from 2 cases of pyogenic spondylitis and 4 cases of metastasis. The results were as follows: 1. The frequent site of involvement were thromboembolic junction and low lumbar vertebrae, and the most frequent type is multisegmented subligamentous type (93.3%). 2. CT was not of great use in the differential diagnosis of the tuberculosis. Dominant CT findings of tuberculous spondylitis were anterior vertebral body destruction, paravertebral soft-tissue mass and thick walled abscess formation occasionally containing calcification and disc space narrowing in the setting of an indolent or relatively benign course. 3. CT is the best modality for imaging the extent and anatomy of the destructive process, the degree of canal encroachment, and the change of adjacent vital structure. So CT was particularly useful in pre-operative planning of debridement and stabilization surgery. 4. The most common causes of neurologic manifestations in tuberculous spondylitis were the compression of spinal cord by sequestrated bony fragments and disc material, granulation tissue or abscess in the spinal canal.

  7. Skin decontamination cream for radiological contaminants: Formulation development and evaluation.

    Science.gov (United States)

    Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed

    2013-01-01

    Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. (99m)Tc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively.

  8. Radiological evaluation of esophageal motility and gastroesophageal reflux disease; Funktionsstoerungen des Oesophagus. Radiologische Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Schima, W. [Abt. Roentgen fuer Konservative Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Pokieser, P. [Abt. Roentgen fuer Chirurgische Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Schober, E. [Abt. Roentgen fuer Konservative Faecher, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    1995-10-01

    Radiological evaluation of esophageal motility and the lower esophageal sphincter has gained increased attention in recent years. Videofluoroscopic investigation of esophageal motor function is superior to static film radiography, as repeated analysis of the videotaped recordings is possible. With emphasis on radiological techniques, normal esophagel physiology and motility and a variety of esophageal motor disorders are discussed in this review paper. Radiological evaluation of gastroesophageal reflux and reflux esophagitis is described. Clinical and radiological findings in esophageal motility disorders and gastroesophageal reflux disease and the radiological efficacy compared to that of manometry and pH-metry are discussed. (orig.) [Deutsch] Die radiologische Untersuchung des Oesophagus kann nicht nur strukturelle Veraenderungen, sondern auch funktionelle Stoerungen mit einer hohen Treffsicherheit nachweisen. Die Videokinematographie ist hierbei der konventionellen Roentgenuntersuchung aufgrund der Moeglichkeit der wiederholten Analyse ueberlegen. Ziel der vorliegenden Uebersicht ist es, prinzipiell das radiologische Erscheinungsbild der normalen Funktion sowie diagnostische Kriterien fuer verschiedene Motilitaetsstoerungen zu demonstrieren. Weiterhin werden auch die verschiedenen Moeglichkeiten der radiologischen Refluxpruefung zur Untersuchung der Funktion des gastrooesophagealen Sphinkters verglichen und deren Wert diskutiert. Die Pruefung der Funktion von Oesophagus und gastrooesophagealem Sphinkter als ein integraler Bestandteil der Roentgenuntersuchung der Speiseroehre verbessert deren Treffsicherheit, wodurch die radiologische Untersuchung die primaere diagnostische Methode bei Patienten mit Schluckstoerungen darstellt. (orig.)

  9. Radiological evaluation of a liver simulator in comparison to a human real liver

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Campos, Tarcisio P.R. de

    2009-01-01

    The present study evaluates the radiological features of a human real healthy liver reproducing its characteristics on a developed liver simulator. The radiological evaluation will be performed through radiological methods such as CT and X-ray images, density and weight measurements, as well as representation of the coloration and texture. According to literature, the liver is the highest weight organ and gland of the body, weighing approximately 1,5 kg. On the liver, the nutrients are absorbed from the digestive tract and are prosecuted and stored for future use by other organs. Also the liver is responsible for the neutralization and elimination of various toxic substances. Thus, it is an interface between the digestive system and the blood. Besides, this organ is the principal source of plasmatic proteins like the albumin, transport of graxos oily acids. Due to its proprieties, the liver holds a large amount of radionuclides on any uptake from external source. The liver simulator was designed to have the same density, weight and corresponding shape. The radiographic image was produced by conventional X-rays machine, in which the radiographic applied parameters were the same applied to abdomen. The result of the radiographic and CT images demonstrates radiological equivalence between the simulator and human real liver. Hounsfield number of the synthetic liver tissue was found on the range of human livers. Therefore, due to its similar shape, chemical composition, radiological response, the liver simulator can be used to investigate ionizing radiation procedures during radiation therapy intervention. (author)

  10. Radiological consequence evaluation of DBAs with alternative source term method for a Chinese PWR

    International Nuclear Information System (INIS)

    Li, J.X.; Cao, X.W.; Tong, L.L.; Huang, G.F.

    2012-01-01

    Highlights: ► Radiological consequence evaluation of DBAs with alternative source term method for a Chinese 900 MWe PWR has been investigated. ► Six typical DBA sequences are analyzed. ► The doses of control room, EAB and outer boundary of LPZ are acceptable. ► The differences between AST method and TID-14844 method are investigated. - Abstract: Since a large amount of fission products may releases into the environment, during the accident progression in nuclear power plants (NPPs), which is a potential hazard to public risk, the radiological consequence should be evaluated for alleviating the hazard. In most Chinese NPPs the method of TID-14844, in which the whole body and thyroid dose criteria is employed as dose criteria, is currently adopted to evaluate the radiological consequences for design-basis accidents (DBAs), but, due to the total effective dose equivalent is employed as dose criteria in alternative radiological source terms (AST) method, it is necessary to evaluate the radiological consequences for DBAs with AST method and to discuss the difference between two methods. By using an integral safety analysis code, an analytical model of the 900 MWe pressurized water reactor (PWR) is built and the radiological consequences in DBAs at control room (CR), exclusion area boundary (EAB), low population zone (LPZ) are analyzed, which includes LOCA and non-LOCA DBAs, such as fuel handling accident (FHA), rod ejection accident (REA), main steam line break (MSLB), steam generator tube rupture (SGTR), locked rotor accident (LRA) by using the guidance of the RG 1.183. The results show that the doses in CR, EAB and LPZ are acceptable compared with dose criteria in RG 1.183 and the differences between AST method and TID-14844 method are also discussed.

  11. Evidence-based radiology: a new approach to evaluate the clinical practice of radiology; Evidenzbasierte Radiologie: Ein neuer Ansatz zur Bewertung von klinisch angewandter radiologischer Diagnostik und Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Puig, S. [Univ.Klinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria); Forschungsprogramm fuer Evidenzbasierte Medizinische Diagnostik, Inst. fuer Public Health, Paracelsus Medizinische Privatuniversitaet, Salzburg (Austria); Felder-Puig, R. [Ludwig-Boltzmann-Inst. fuer Health Technology Assessment, Vienna (Austria)

    2006-07-15

    Over the last several years, the concept and methodology of evidence-based medicine (EBM) have received significant attention in the scientific community. However, compared to therapeutic medical disciplines, EBM-based radiological publications are still underrepresented. This article summarizes the principles of EBM and discusses the possibilities of their application in radiology. The presented topics include the critical appraisal of studies on the basis on EBM principles, the explanation of EBM-relevant statistical outcome parameters (e.g., ''likelihood ratio'' for diagnostic and ''number needed to treat'' for interventional procedures), as well as the problems facing evidence-based radiology. Evidence-based evaluation of radiological procedures does not only address aspects of cost-effectiveness, but is also particularly helpful in identifying patient-specific usefulness. Therefore it should become an integral part of radiologist training. (orig.)

  12. Radiological evaluation of intestinal obstruction in neonate and infant

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, D. S.; Lim, K. Y.; Kim, S. J.; Kim, J. D.; Rhee, H. S. [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    1980-12-15

    281 cases of neonatal and infantile intestinal obstruction confirmed by clinical and surgical procedure from 1975 till 1979 were reviewed radiologically. The result was as follows; 1. Intussusception was the most common cause of intestinal obstruction under one year of age (173/281: 61.56%), and other causes of descending order were infantile hypertrophic pyloric stenosis (20: 7.11%), congenital megacolon (19: 6.76%), anorectal malformation (17: 6.05%), meconium plug syndrome (17: 6.05%), hernia (12: 4.27%), band adhesion (8: 2.85%), rotation anomaly (5: 1.78%), small bowel atresia (3: 1.07%), Meckel's diverticulum (3: 1.07%), duodenal atresia (2: 0.71%), meconium ileus (1: 0.36%) and annular pancreas (1: 0.36%). Congenital type of intestinal obstruction (we classified intussusception acquired and others congenital) occupied 38.44%. 2. The ratio of male to female was 3: 1, congenital type 4.69 : 1 and acquired 2.39 : 1. 3. Vomiting, bloody stool, fever and abdominal distention were the most 4 symptoms. 4. The frequency of typical mechanical ileus pattern on plain abdomen films was 226 cases(80.43%) paralytic ileus or normal finding was 52 cases (18.51%) and pneumoperitoneum with ileus sign was 3 cases (1.06%). 5. Barium meal or enema was performed in 228 cases and narrowing or obstructed site was found in 213 cases of them (93.42%); intussusception 100% (173/173), infantile hypertrophic pyloric stenosis 93.33% (14/15) and congenital megacolon 82.35% (14/17). 6. Only 10 cases had associated disease such as Mongolism, thoracic kyphosis and scoliosis, microcolon, prematurity, ileocolic fistula, undescended testicle and hydrocele. 7. Meconium plug syndrome, duodenal atresia, small bowel atresia, mecondium ileus and annular pancreas were developed early after birth with average onset age of 3.6 days.

  13. Radiological evaluation of intestinal obstruction in neonate and infant

    International Nuclear Information System (INIS)

    Jeon, D. S.; Lim, K. Y.; Kim, S. J.; Kim, J. D.; Rhee, H. S.

    1980-01-01

    281 cases of neonatal and infantile intestinal obstruction confirmed by clinical and surgical procedure from 1975 till 1979 were reviewed radiologically. The result was as follows; 1. Intussusception was the most common cause of intestinal obstruction under one year of age (173/281: 61.56%), and other causes of descending order were infantile hypertrophic pyloric stenosis (20: 7.11%), congenital megacolon (19: 6.76%), anorectal malformation (17: 6.05%), meconium plug syndrome (17: 6.05%), hernia (12: 4.27%), band adhesion (8: 2.85%), rotation anomaly (5: 1.78%), small bowel atresia (3: 1.07%), Meckel's diverticulum (3: 1.07%), duodenal atresia (2: 0.71%), meconium ileus (1: 0.36%) and annular pancreas (1: 0.36%). Congenital type of intestinal obstruction (we classified intussusception acquired and others congenital) occupied 38.44%. 2. The ratio of male to female was 3: 1, congenital type 4.69 : 1 and acquired 2.39 : 1. 3. Vomiting, bloody stool, fever and abdominal distention were the most 4 symptoms. 4. The frequency of typical mechanical ileus pattern on plain abdomen films was 226 cases(80.43%) paralytic ileus or normal finding was 52 cases (18.51%) and pneumoperitoneum with ileus sign was 3 cases (1.06%). 5. Barium meal or enema was performed in 228 cases and narrowing or obstructed site was found in 213 cases of them (93.42%); intussusception 100% (173/173), infantile hypertrophic pyloric stenosis 93.33% (14/15) and congenital megacolon 82.35% (14/17). 6. Only 10 cases had associated disease such as Mongolism, thoracic kyphosis and scoliosis, microcolon, prematurity, ileocolic fistula, undescended testicle and hydrocele. 7. Meconium plug syndrome, duodenal atresia, small bowel atresia, mecondium ileus and annular pancreas were developed early after birth with average onset age of 3.6 days

  14. Evaluation of medical and occupational exposures in interventional radiology

    International Nuclear Information System (INIS)

    Maekoshi, Hisashi; Ishiguchi, Tsuneo; Tsuzaka, Masatoshi; Tamiya, Tadashi; Nakamura, Kiyoko.

    1992-01-01

    Absorbed radiation doses received by patients and personnel during interventional procedures were estimated in this study. An Angiostar, a fluoroscopy x-ray unit, made by Siemens Co. Ltd. was used. Fluoroscopic conditions were 82 to 112 kV of tube voltage and 2.5 to 4.3 mA of tube current. The absorbed doses to the ovaries were measured in a Mix-Dp phantom after the image intensifier's field size was changed from 40 cm to 14 cm in diameter. X-ray scattering dose distributions in the vicinity of the fluoroscopy table were measured by an ionization survey meter. This measurement was carried out concurrently with the above x-ray exposure conditions. Patient and personnel exposure increased in relation to the decreased field size. These medical and occupational exposures increases were the result of the x-ray output gradually increasing as the image intensifier's field was progressively decreased. This condition was caused by the automatic brightness control circuits of the x-ray unit. When the smallest field size of the image intensifier (I.I.) was employed the exposure doses absorbed by both patients and personnel were about three times larger than the doses received in the largest field size. (author)

  15. A Descriptive Evaluation of Software Sizing Models

    Science.gov (United States)

    1987-09-01

    2-22 2.3.2 SPQR Sizer/FP ............................... 2-25 2.3.3 QSM Size Planner: Function Points .......... 2-26 2.3.4 Feature...Characteristics ............................. 4-20 4.5.3 Results and Conclusions ..................... 4-20 4.6 Application of the SPQR SIZER/FP Approach...4-19 4-7 SPQR Function Point Estimate for the CATSS Sensitivity Model .................................................. 4-23 4-8 ASSET-R

  16. Effects of the platelet rich plasma on apexogenesis in young monkeys: Radiological and hystologycal evaluation

    Directory of Open Access Journals (Sweden)

    Petrović Vanja

    2012-01-01

    Full Text Available Platelet-reach plasma (PRP is an attractive tool in regenerative medicine due to its ability to stimulate proliferation and differentiation of stem cells. Since dental pulp derived stem cells are recognized as central in apexogenesis, the aim of the study was to evaluate radiologically and histologically effects of PRP on apexogenesis in teeth with immature roots. The study included eight monkeys (Cercopithecus Aethiops divided in two equal groups for evaluation 3 and 12 months after treatment. All participants obtained the same treatment including pulpotomy and after-treatment with: hydroxiapatite (HA-incisor and HA+canine PRP. Radiological evaluation was performed using the long cone paralleling technique for recording of defined parameters and histological evaluation was performed using tissue removed en block for the observation of parameters related to apexogenesis. The results obtained radiologically and histologically have shown increase in bridge formation in HA+PRP (75% group after 3 months comparing to HA group (50%. Contrary to that, after 12 months there were no significant differences between groups. The root delay was not registered in the HA+PRP group contrary to HA group where it was registered in 25% after 12 months. Results of the study suggest that PRP is a powerful tool for intensive and rapid apexogenesis since it offers clear and comprehensive results (mostly in the first three months which are early radiologically visible without any failure in the proposed requests.

  17. Investigation of evaluation method for marine radiological impact during an accident

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    In 2012, JNES carried out to investigate the measurement information of radionuclide released to the ocean at Fukushima Daiichi NPP accident, the foreign regulation for marine radiological impact, and the evaluation method for release and diffusion to the ocean at the accident inside and outside Japan. (author)

  18. Effects of the Platelet Rich Plasma on Apexogenesis in Young Monkeys: Radiological and Hystologycal Evaluation

    International Nuclear Information System (INIS)

    Petrović, Vanja; Pejčić, Natasa; Rakić, Mia; Leković, V.; Stojić, Ž; Vasić, Una

    2012-01-01

    Platelet-reach plasma (PRP) is an attractive tool in regenerative medicine due to its ability to stimulate proliferation and differentiation of stem cells. Since dental pulp derived stem cells are recognized as central in apexogenesis, the aim of the study was to evaluate radiologically and histologically effects of PRP on apexogenesis in teeth with immature roots. The study included eight monkeys (Cercopithecus Aethiops) divided in two equal groups for evaluation 3 and 12 months after treatment. All participants obtained the same treatment including pulpotomy and after-treatment with: hydroxiapatite (HA)-incisor and HA+canine PRP. Radiological evaluation was performed using the long cone paralleling technique for recording of defined parameters and histological evaluation was performed using tissue removed en block for the observation of parameters related to apexogenesis. The results obtained radiologically and histologically have shown increase in bridge formation in HA+PRP (75%) group after 3 months comparing to HA group (50%). Contrary to that, after 12 months there were no significant differences between groups. The root delay was not registered in the HA+PRP group contrary to HA group where it was registered in 25% after 12 months. Results of the study suggest that PRP is a powerful tool for intensive and rapid apexogenesis since it offers clear and comprehensive results (mostly in the first three months) which are early radiologically visible without any failure in the proposed requests

  19. Effects of the Platelet Rich Plasma on Apexogenesis in Young Monkeys: Radiological and Hystologycal Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Petrović, Vanja; Pejčić, Natasa; Rakić, Mia; Leković, V.; Stojić, Ž [University of Belgrade, School of Dentistry (Serbia); Vasić, Una [University of Belgrade, Faculty of Medicine (Serbia)

    2012-07-01

    Platelet-reach plasma (PRP) is an attractive tool in regenerative medicine due to its ability to stimulate proliferation and differentiation of stem cells. Since dental pulp derived stem cells are recognized as central in apexogenesis, the aim of the study was to evaluate radiologically and histologically effects of PRP on apexogenesis in teeth with immature roots. The study included eight monkeys (Cercopithecus Aethiops) divided in two equal groups for evaluation 3 and 12 months after treatment. All participants obtained the same treatment including pulpotomy and after-treatment with: hydroxiapatite (HA)-incisor and HA+canine PRP. Radiological evaluation was performed using the long cone paralleling technique for recording of defined parameters and histological evaluation was performed using tissue removed en block for the observation of parameters related to apexogenesis. The results obtained radiologically and histologically have shown increase in bridge formation in HA+PRP (75%) group after 3 months comparing to HA group (50%). Contrary to that, after 12 months there were no significant differences between groups. The root delay was not registered in the HA+PRP group contrary to HA group where it was registered in 25% after 12 months. Results of the study suggest that PRP is a powerful tool for intensive and rapid apexogenesis since it offers clear and comprehensive results (mostly in the first three months) which are early radiologically visible without any failure in the proposed requests.

  20. EVALUATION OF THE ADA TECHNOLOGIES' ELECTRO-DECON PROCESS TO REMOVE RADIOLOGICAL CONTAMINATION

    International Nuclear Information System (INIS)

    Pao, Jenn-Hai; Demmer, Rick L.; Argyle, Mark D.; Veatch, Brad D.

    2003-01-01

    A surface decontamination system featuring the use of ADA's electrochemical process was tested and evaluated. The process can be flexibly deployed by using an electrolyte delivery system that has been demonstrated to be reliable and effective. Experimental results demonstrate the effectiveness of this system for the surface decontamination of radiologically contaminated stainless steel

  1. Radiological investigation of renovascular hypertension from IVU to digital subtraction angiography. A critical evaluation

    International Nuclear Information System (INIS)

    Amiel, M.; Froment, A.; Pinet, F.; Huguet, M.

    1986-01-01

    For the last 20 years, the value of radiology in renovascular hypertension (RVH) is well established from diagnostic and therapeutic points of view. However things are changing now due to a better appraisal of the incidence of RVH, new antihypertensive drugs, and new radiological procedures (digital angiography, percutaneous transluminal angioplasty). The approach now takes in account the mode of imaging for a better evaluation of the renal artery stenosis and costs of the proceedings as well. Finally a new strategy has been set up for RVH patients management [fr

  2. Evaluation of diagnostic radiology services in five Latin American countries: Results for mammography

    International Nuclear Information System (INIS)

    Brandan, M.E.; Caspani, C.E.M.; Mora, R. de la; Miranda, A.A.; Plazas, M.-C.; Borras, C.

    2001-01-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of experts. We present preliminary results from mammographic imaging facilities, which indicate that the failure to comply with the international standards of quality control produces images of unacceptable quality, as measured either by using a phantom or by an independent evaluation of the clinical images. (author)

  3. Diagnosis of cystocele--the correlation between clinical and radiological evaluation.

    Science.gov (United States)

    Altman, Daniel; Mellgren, Anders; Kierkegaard, Jonas; Zetterström, Jan; Falconer, Christian; López, Annika

    2004-01-01

    In patients with genital prolapse involving several compartments simultaneously, radiologic investigation can be used to complement the clinical assessment. Contrast medium in the urinary bladder enables visualization of the bladder base at cystodefecoperitoneography (CDP). The aim of the present study was to evaluate the correlation between clinical examination using the Pelvic Organ Prolapse Quantification system (POP-Q) and CDP. Thirty-three women underwent clinical assessment and CDP. Statistical analysis using Pearson's correlation coefficient ( r) demonstrated a wide variability between the current definition of cystocele at CDP and POP-Q ( r=0.67). An attempt to provide an alternative definition of cystocele at CDP had a similar outcome ( r=0.63). The present study demonstrates a moderate correlation between clinical and radiologic findings in patients with anterior vaginal wall prolapse. It does not support the use of bladder contrast at radiologic investigation in the routine preoperative assessment of patients with genital prolapse.

  4. Preliminary evaluation of the radiological quality of the water on Bikini and Eneu Islands

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Brown, G.

    1975-01-01

    In June of 1975 a survey was conducted to determine the residual radioactivity in the terrestrial environment on the two main islands (Eneu and Bikini) of Bikini Atoll. The objective was to evaluate the potential radiation doses that could be received by the Bikinians scheduled to return to their atoll. This report describes the radiological quality of the groundwater during June 1975 (from data obtained from water samples collected at old and new well sites on both islets) and the cistern water on Bikini island. Based on the analyses of these samples, the cistern water from Bikini Island is both chemically and radiologically acceptable as drinking water in accordance with standard limits established by the U. S. Public Health Service. On both islands the quality of the ground water varies from one site to another. At some wells both chemical and radiological quality are acceptable; at others one or both is unacceptable according to U. S. Public Health Standards

  5. Analysis and evaluation of the radiological aspects of scoliosis

    International Nuclear Information System (INIS)

    Vargas Gonzalez, Paula

    2012-01-01

    The theme of scoliosis is proposed from the radiological perspective. An extensive literature review is realized, extracting the most relevant information for research. The initiation and evolution of scoliosis has been silent, therefore, to meet this condition has been important to detect it early and opportunely, before that curvatures have progressed and become structured, forcing the surgical treatment. The timely correction of curvatures in the spine has generated significant conditions in the patient's life. The early diagnosis has been fundamental to realize an opportune treatment of orthopedic type. A great variety of congenital and developmental disorders have been evident in the spine. The causes and patterns of the abnormal curvature of the spine have been varied. Precise diagnosis of these alterations is supported on a careful clinical assessment and is aided by imaging explorations, such as conventional radiography, computed tomography, ultrasound and magnetic resonance. Imaging methods to detect scoliosis are mentioned. The measurement procedures of the angle of spine curve are determined. The classification of scoliosis according to King-Lenke are cited to facilitate objective assessment of a disease for examiners, making that the results are presented in shape uniform and comparable possible. The types of scoliosis are explained. The characterization of the deformities of the axis of the spine, quantification and estimation of the degree of skeletal maturity has been the principal objective of the spine radiography. In an radiography has been important to be included all the thoracolumbar spine from C7. The Cobb and Ferguson measurements are used to measure angles, Risser for skeletal maturation, Nas and Moe for vertical rotation. Congenital deformities should be taken into account in radiographs of spine. Each vertebra is examined minutely in search of malformations of fusion, etc., that explain scoliosis. In neurological disorders, to take

  6. Impact of focal spot size on radiologic image quality: A visual grading analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gorham, Sinead [Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, Health Science, Belfield, UCD, Dublin 4 (Ireland); Brennan, Patrick C., E-mail: patrick.brennan@ucd.i [Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, Health Science, Belfield, UCD, Dublin 4 (Ireland)

    2010-11-15

    Fine and broad focal spot sizes are available on general X-ray tubes. Excessive use of fine focus can impact on tube life and whilst it is established that fine focal spot size reduces geometric unsharpness, the extent of this benefit on clinical image quality is unclear. The current cadaver-based work compares images produced with effective focal sizes of 0.8 mm and 1.8 mm. Four projection types were included, lateral ankle, antero-posterior (AP) knee, AP thoracic spine and horizontal beam lateral (HBL) lumbar spine, and a visual grading analysis was used to assess visibility of anatomical criteria. Five clinicians scored each image using a 1-4 scoring scale, a reference image was employed for standardization and a Mann-Whitney U statistical test compared results derived from each focus. Radiation doses were monitored using a dose area product (DAP) meter. Statistical analyses demonstrated no significant differences between images produced at each focus, although a relationship between body part thickness and number of criteria with a higher (non-significant) score for the fine focus compared with the broad focal spot size was demonstrated. Choice of focus had no radiation dose implications. Fine foci X-ray sources are used predominantly for extremity imaging to enhance visualization of fine detail such as trabecular patterns, yet there is no evidence to support this practice. The argument for regular employment of fine foci, particularly for the type of acquisition and display devices used in this study, needs to be revisited.

  7. Radiological evaluation of long term complications of oral rehabilitations of thin ridges with titanium blade implants

    Directory of Open Access Journals (Sweden)

    P. Diotallevi

    2014-03-01

    Full Text Available Aim: The aim of this study was to assess the sensitivity of orthopantomography (OPT in the diagnosis of long term complications in oral rehabilitations with blade implants. Materials and methods A total of 235 blade implants in 189 patients, inserted between 1988 and 2003, were retrospectively analyzed. The records consisted of a first OPT taken between January and December 2010, and a second one 12 months after. The evaluation of implant health considered: integrity of the blade, normal radiological representation of the bone around the implant, dense and cortical appearance of bone around the implant collar. The evaluation of radiological complications considered: implant fracture, bone resorption around the implant, recession of the bone around the implant collar. Results The sensitivity of the panoramic evaluation was equal to 100%. The complications detected were 5 cases of periimplantitis, 9 cases of bone pericervical bone recession and 3 cases of fracture of the implant body. In cases of pericervical bone resorption the following radiological check up 12 months after the first one showed the progression of the disease in 6 out of 9 cases, with irreversible implant failure. In subjects with a radiological pattern of implant health there were no complications in the subsequent check up after 12 months. In the subjects with complications the specificity was equal to 100%. Conclusion The radiographic evaluation by the means of OPT has shown high sensitivity in the diagnosis of long term complications of oral rehabilitations with blade implants and allows prompt therapeutic interventions. Radiological complications appeared mostly in the long term check ups and mainly consisted in recession of the bone around the neck or around the entire implant. More rarely implant fractures occurred, which, in the case of blades, sometimes were not associated with any clinical symptoms: therefore, postsurgical evaluation should not be separated from

  8. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    Science.gov (United States)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  9. Application gives the technique the analytic tree in the evaluation the effectiveness programs to radiological protection

    International Nuclear Information System (INIS)

    Perez Gonzalez, F.; Perez Velazquez, R.S.; Fornet Rodriguez, O.; Mustelier Hechevarria, A.; Miller Clemente, A.

    1998-01-01

    In the work we develop the IAEA recommendations in the application the analytic tree as instrument for the evaluation the effectiveness the occupational radiological protection programs. Is reflected like it has been assimilated and converted that technique in daily work istruments in the evaluation process the security conditions in the institutions that apply the nuclear techniques with a view to its autorization on the part of the regulatory organ

  10. Injuries of the spine: Current concepts of radiological evaluation

    International Nuclear Information System (INIS)

    Du Mesnil de Rochemont, R.; Lanfermann, H.; Heindel, W.

    1997-01-01

    This review discusses the usefulness of plain radiography, computed tomography (CT), and magnetic resonance imaging (MRI) in the evaluation of spinal trauma. The indications for the different imaging modalities in dependence on the specific pattern of injury are explored. Plain radiography still remains the prime method in the diagnosis of acute spinal trauma but there are substantial deficits, especially in the evaluation of the occipitocervical and the cervicothoracic junction as well as in the evaluation of the integrity of posterior vertebral body line. If injury in these regions is suspected CT should follow plain radiography immediately. In the case of spinal trauma with unexplained neurologic deficits MRI is the method of choice for the detection of spinal cord injury. Recommendations with regard to instability and the classification of specific injuries, including examples of typical findings are presented. (orig.) [de

  11. Evaluation process radiological in ternopil region method of box models

    Directory of Open Access Journals (Sweden)

    І.В. Матвєєва

    2006-02-01

    Full Text Available  Results of radionuclides Sr-90 flows analyses in the ecosystem of Kotsubinchiky village of Ternopolskaya oblast were analyzed. The block-scheme of ecosystem and its mathematical model using the box models method were made. It allowed us to evaluate the ways of dose’s loadings formation of internal irradiation for miscellaneous population groups – working people, retirees, children, and also to prognose the dynamic of these loadings during the years after the Chernobyl accident.

  12. Radiological evaluation of esophageal speech on total laryngectomee

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Gwi Eon; Hong, Won Phy; Lee, Won Sang

    1988-01-01

    Total laryngectomee requires some form of alaryngeal speech for communication. Generally, esophageal speech is regarded as the most available and comfortable technique for alaryngeal speech. But esophageal speech is difficult to train, so many patients are unable to attain esophageal speech for communication. To understand mechanism of esophageal of esophageal speech on total laryngectomee, evaluation of anatomical change of the pharyngoesophageal segment is very important. We used video fluoroscopy for evaluation of pharyngesophageal segment during esophageal speech. Eighteen total laryngectomees were evaluated with video fluoroscopy from Dec. 1986 to May 1987 at Y.U.M.C. Our results were as follows: 1. Peseudoglottis is the most important factor for esophageal speech, which is visualized in 7 cases among 8 cases of excellent esophageal speech group. 2. Two cases of longer A-P diameter at the pseudoglottis have the best quality of esophageal speech than others. 3. Two cases of mucosal vibration at the pharyngoesophageal segment can make excellent esophageal speech. 4. The cases of failed esophageal speech are poor aerophagia in 6 cases, abscence of pseudoglottis in 4 cases and poor air ejection in 3 cases. 5. Aerophagia synchronizes with diaphragmatic motion in 8 cases of excellent esophageal speech.

  13. Evaluation of radiology as a tool to diagnose pulmonic lesions in calves, for example prior to experimental infection studies

    DEFF Research Database (Denmark)

    Tegtmeier, Conny; Arnbjerg, J.

    2000-01-01

    The aim of the study was to evaluate radiology as a technique to visualize pulmonary lesions in young calves, e.g. as a selection criterion for research animals in order to eliminate animals with lung lesions Drier to experimental studies of pneumonia. Five calves with acute clinical signs...... of pneumonia were included in a direct comparative study of radiological and post mortem findings. Also, a number of animals with no signs of pneumonia were included as controls. The study revealed good agreement between the radiological and post mortem findings. Thus, in conclusion, radiology should...

  14. Evaluation of radiological dispersion/consequence codes supporting DOE nuclear facility SARs

    International Nuclear Information System (INIS)

    O'Kula, K.R.; Paik, I.K.; Chung, D.Y.

    1996-01-01

    Since the early 1990s, the authorization basis documentation of many U.S. Department of Energy (DOE) nuclear facilities has been upgraded to comply with DOE orders and standards. In this process, many safety analyses have been revised. Unfortunately, there has been nonuniform application of software, and the most appropriate computer and engineering methodologies often are not applied. A DOE Accident Phenomenology and Consequence (APAC) Methodology Evaluation Program was originated at the request of DOE Defense Programs to evaluate the safety analysis methodologies used in nuclear facility authorization basis documentation and to define future cost-effective support and development initiatives. Six areas, including source term development (fire, spills, and explosion analysis), in-facility transport, and dispersion/ consequence analysis (chemical and radiological) are contained in the APAC program. The evaluation process, codes considered, key results, and recommendations for future model and software development of the Radiological Dispersion/Consequence Working Group are summarized in this paper

  15. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  16. Services of radiological protection: as sizing the human and material resources; Como dimensionar los recursos humanos y materiales: un proyecto del Foro de Proteccion Radiologica en el Medio Sanitario

    Energy Technology Data Exchange (ETDEWEB)

    Rueda Guerrero, M. D.; Sierra Perler, I.; Lorenzo Perez, P.

    2014-07-01

    Discussion of radiological protection in the Middle Health has formed a task force to develop a technical document recommendatory to help plan and evaluate resources radiological protection services. (Author)

  17. Radiologic evaluation of the horse relevant to purchase

    International Nuclear Information System (INIS)

    Poulos, P.W. Jr.

    1992-01-01

    Adequate radiographic evaluation of the horse relevant to purchase examination requires the successful integration of technique, interpretation, and reporting. A thorough knowledge of lameness and disease can be masked by incorrect interpretation resulting from poor-quality films or an incomplete examination. Thus, care must be taken to produce an adequate number of high-quality films on which to base a report, which allows you to describe changes that are present. This information, coupled with your physical examination, other laboratory data, and the knowledge of the expressed use of the horse will allow you to advise prospective owners on the decision that they will ultimately make

  18. Radiologic and histopathologic evaluation of various contrast media for bronchography

    International Nuclear Information System (INIS)

    Kang, Eun Young; Hong, Ki Taek; Kim, Jin Hyung; Kim, Hyung Rae; Shin, Bong Kyung; Oh, Yu Whan; Kim, Han Kyeom; Park, Cheol Min; Seol, Hae Young; Cha, In Ho

    1999-01-01

    To determine which contrast media are both efficient and safe for the imaging of airways. We evaluated five contrast media (barium, gastrografin, iotrolan, ioxaglate, iopentol) in terms of image quality and their effects on the lungs of 25 white rabbits. For bronchography 0.5ml of contrast media was used. In each contrast group, HRCT scans were obtained immediately (n=5), 12 hours (n=4), 1 day (n=3), 2 days (n=2), and 1 week (n=1) after bronchography. Histopathologic specimens were obtained immediately, 12 hours, 1 day, 2 days, and 1 week later. Bronchograms were evaluated for image quality by three radiologists working independently, and were scored as 1(poor), 2(moderate), or 3(good) in terms of contrast quality and bronchial coating. HRCT was evaluated by two radiologists who reached a concensus;they determined the presence of contrast media, and then the pattern and extent of pulmonary opacity, and any related changes. Histopatholgic specimens were evaluated by two pathologists who sought consensus as to the extent of inflammation, pulmonary edema, and hemorrhage, and any changes in these aspects. Bronchography indicated that the sum of scores for contrast quality was 45 for barium, 33 for gastrografin, 28 for iotrolan, 30 for ioxaglate, and 28 for iopentol, while for each of these media, the sum of scores for bronchial coating was 39, 19, 25, 23, and 21, respectively. Barium showed the best image quality. In all rabbits, HRCT demonstrated the variable extent of ground-glass attenuation and/or consolidation. Lesions were most extensive at 1-2days and then regressed at 1 week;these HRCT findings correlated well with histologic findings. In histologic studies of all five contrast media groups, variable severe inflammatory reactions were observed, with or without necrosis, congesion, edema, and hemorrhage. It was noted that ioxaglate appeared to cause least tissue reaction. The imaging results of this experimental study indicate that for bronchography, barium is

  19. Development and validation of a questionnaire to evaluate infection control in oral radiology

    Science.gov (United States)

    Pinelli, Camila; da Silva Tagliaferro, Elaine P; Corrente, José E; Ambrosano, Glaucia M B

    2017-01-01

    Objectives: To create and validate a questionnaire to evaluate infection control in oral radiology. Methods: The questionnaire was developed after review of the literature, which included published articles and the biosafety protocols available from healthcare agencies. The initial version of the questionnaire was composed of 14 multiple choice questions and was divided into 3 domains on handwashing, disinfection/protection of surfaces and disinfectant used. Content validity was assessed by two expert committees, which reviewed the content and scope of the questionnaire and the relevance of each item, respectively. Reliability was evaluated using test–retest and internal consistency methods with 115 undergraduate dentistry students. Construct validity was assessed using the known-groups technique and factor analysis. The known-groups technique involved 641 undergraduate dentistry students, 20 PhD students and 15 oral radiology professors. In the factor analysis, 3 radiology technicians also participated in addition to the 641 undergraduates, 20 PhD students and 15 oral radiology professors. Results: The content validity results were found to be satisfactory to excellent for the ordinal variables (intraclass correlation coefficient = 0.722–1.000) and good to great for the yes/no questions (kappa = 0.662–0.913) in terms of reliability and good internal consistency (Cronbach's alpha = 0.88). After a factor analysis, some questions were excluded, and the questions were grouped into new domains. Significant differences were observed between answers from different groups. The final version of the questionnaire was composed of nine domains. Conclusions: The questionnaire created was found to exhibit good psychometric properties for assessing infection control in oral radiology. PMID:28112553

  20. Radiological evaluation of the intraabdominal masses in childhood

    International Nuclear Information System (INIS)

    Kim, Y. J.; Oh, K. K.; Park, C. Y.

    1980-01-01

    The spectrum of types of cancer in childhood differs strikingly from that in adults. Leukemia, central nervous system tumors, embryonal tumors, and sarcomas are much more common in children than are adenocarcinoma and carcinomas, which constitute the majority of cancers in adults. In children under 15 years of age, intraabdominal tumors are the third most common one, preceded only by leukemia and brain tumors. It is well recognized that these tumors remain silent until they assume huge size, and early detection and treatment are important. X-ray examination is the most important method among diagnostic approaches. 150 cases of intraabdominal masses were reviewed in respect of age, sex, incidence, site of origin and radiographic findings. The results are summarized as follows; 1. The most common site was retroperitoneum (80 cases: 53.3%), followed by intraperitoneum (47 cases: 31.3%), and pelvic cavity (23 cases: 15.4%). The kidney was the single most common site of origin (33%). 2. Hydronephrosis was most common (23 cases: 15.3%) and Wilms' tumor (22 cases: 14.7%), teratoma (21 cases: 14.0%), and neuroblastoma (18 cases: 12.0%) were descending order of frequency. One renal cell carcinoma in 9 year old female patient and bilateral duplications of pelvis with ureteroceles in 5 month old twin infants were found. 3. Male outnumbered female in most childhood abdominal diseases, however female was predominant in teratoma (1:20) and choledochal cyst (3:7). 97 cases were under the age of 5 years. 4. Radiographic findings were as follow, a. Simple abdomen: In retroperitoneal tumors, mass shadows were the most common finding (89.7%) and obliteration of psoas shadows was noted in 73%. Calcifications were seen in 6 cases (100%) of teratoma as bone, teeth or amorphous, 1 case (4.5%) of Wilms' tumor as amorphous, and 5 cases (33%) or neuroblastoma as amorphous or psammomatous. Fat shadow was seen in 5 cases (83%) of teratoma. In intraperitoneal tumors, mass was the most common

  1. Radiological Evaluation of Ambiguous Genitalia with Various Imaging Modalities

    Science.gov (United States)

    Ravi, N.; Bindushree, Kadakola

    2012-07-01

    Disorders of sex development (DSDs) are congenital conditions in which the development of chromosomal, gonadal, or anatomic sex is atypical. These can be classified broadly into four categories on the basis of gonadal histologic features: female pseudohermaphroditism (46,XX with two ovaries); male pseudohermaphroditism (46,XY with two testes); true hermaphroditism (ovotesticular DSD) (both ovarian and testicular tissues); and gonadal dysgenesis, either mixed (a testis and a streak gonad) or pure (bilateral streak gonads). Imaging plays an important role in demonstrating the anatomy and associated anomalies. Ultrasonography is the primary modality for demonstrating internal organs and magnetic resonance imaging is used as an adjunct modality to assess for internal gonads and genitalia. Early and appropriate gender assignment is necessary for healthy physical and psychologic development of children with ambiguous genitalia. Gender assignment can be facilitated with a team approach that involves a pediatric endocrinologist, geneticist, urologist, psychiatrist, social worker, neonatologist, nurse, and radiologist, allowing timely diagnosis and proper management. We describe case series on ambiguous genitalia presented to our department who were evaluated with multiple imaging modalities.

  2. Evaluation of droplet size distributions using univariate and multivariate approaches

    DEFF Research Database (Denmark)

    Gauno, M.H.; Larsen, C.C.; Vilhelmsen, T.

    2013-01-01

    of the distribution. The current study was aiming to compare univariate and multivariate approach in evaluating droplet size distributions. As a model system, the atomization of a coating solution from a two-fluid nozzle was investigated. The effect of three process parameters (concentration of ethyl cellulose...... in ethanol, atomizing air pressure, and flow rate of coating solution) on the droplet size and droplet size distribution using a full mixed factorial design was used. The droplet size produced by a two-fluid nozzle was measured by laser diffraction and reported as volume based size distribution....... Investigation of loading and score plots from principal component analysis (PCA) revealed additional information on the droplet size distributions and it was possible to identify univariate statistics (volume median droplet size), which were similar, however, originating from varying droplet size distributions...

  3. Evaluation of the radiological protection in several departments of nuclear medicine

    International Nuclear Information System (INIS)

    Lopez Bejerano, G.; Jova Sed, L.

    2001-01-01

    For the evaluation of radiation protection, in several departments of nuclear medicine a survey was elaborated and applied that includes mainly: aspects of the licence and compliance with the requirements settled down in this, the program of individual radiological surveillance and their evaluation, functions that it completes the service of radiation protection, training program and the personnel's training, equipment and means of radiation protection, radiological surveillance program of the work areas, characteristics of the installation, radioactive waste management, quality assurance program, relative aspects to radiation protection in the procedures of diagnoses, as well as to pregnant patients and those related with the investigation of accidental medical exposures. The work makes a systematization and discussion of the state of compliance of the radiation protection requirements reflected in the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) and the main recommendations are exposed to achieve in these departments the optimization of the radiation protection. (author)

  4. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology

    International Nuclear Information System (INIS)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C.; Melo, Camila S.; Furquim, Tania A.C.

    2009-01-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  5. Investigation of evaluation method for marine radiological impact during an accident

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    In 2012, JNES investigated the evaluation method, long-term seawater and marine deposition for release and diffusion to the ocean at the accident, and marine impact assessment code, in Japan and overseas. Also, the foreign regulations for marine radiological impact (direct release to ocean from the facilities and fallout on marine, etc.) were investigated. Furthermore, the index (e.g., intervention level) at emergency control in USA and Europe were investigated. (author)

  6. Investigation of evaluation method for marine radiological impact during an accident

    International Nuclear Information System (INIS)

    2013-01-01

    In 2012, JNES investigated the evaluation method, long-term seawater and marine deposition for release and diffusion to the ocean at the accident, and marine impact assessment code, in Japan and overseas. Also, the foreign regulations for marine radiological impact (direct release to ocean from the facilities and fallout on marine, etc.) were investigated. Furthermore, the index (e.g., intervention level) at emergency control in USA and Europe were investigated. (author)

  7. Multi-criteria analysis for evaluating the radiological and ecological safety measures in radioactive waste management

    International Nuclear Information System (INIS)

    Sazykina, T.G.; Kryshev, I.I.

    2006-01-01

    A methodological approach is presented for multicriterial evaluating the effectiveness of radiation ecological safety measures during radioactive waste management. The approach is based on multicriterial analysis with consideration of radiological, ecological, social, economical consequences of various safety measures. The application of the multicriterial approach is demonstrated taking as an example of decision-making on the most effective actions for rehabilitation of a water subject, contaminated with radionuclides [ru

  8. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  9. American College of Radiology Accreditation Program for mammographic screening sites: Physical evaluation criteria

    International Nuclear Information System (INIS)

    Hendrick, R.E.; Haus, A.G.; Hubbard, L.B.; Lasky, H.J.; McCrohan, J.; McLelland, R.; Rothenberg, L.N.; Tanner, R.L.; Zinninger, M.D.

    1987-01-01

    The American College of Radiology has initiated a program for the accreditation of mammographic screening sites, which includes evaluation by mail of image quality and average glandular breast dose. Image quality is evaluated by use of a specially designed phantom (a modified RMI 152D Mammographic Phantom) containing simulated microcalcifications, fibrils and masses. Average glandular dose to a simulated 4.5-cm-thick (50% glandular, 50% fat) compressed breast is evaluated by thermoluminescent dosimeter measurements of entrance exposure and half value layer. Standards for acceptable image quality and patient doses are presented and preliminary results of the accreditation program are discussed

  10. Text Simplification Using Consumer Health Vocabulary to Generate Patient-Centered Radiology Reporting: Translation and Evaluation.

    Science.gov (United States)

    Qenam, Basel; Kim, Tae Youn; Carroll, Mark J; Hogarth, Michael

    2017-12-18

    Radiology reporting is a clinically oriented form of documentation that reflects critical information for patients about their health care processes. Realizing its importance, many medical institutions have started providing radiology reports in patient portals. The gain, however, can be limited because of medical language barriers, which require a way for customizing these reports for patients. The open-access, collaborative consumer health vocabulary (CHV) is a terminology system created for such purposes and can be the basis of lexical simplification processes for clinical notes. The aim of this study was to examine the comprehensibility and suitability of CHV in simplifying radiology reports for consumers. This was done by characterizing the content coverage and the lexical similarity between the terms in the reports and the CHV-preferred terms. The overall procedure was divided into the following two main stages: (1) translation and (2) evaluation. The translation process involved using MetaMap to link terms in the reports to CHV concepts. This is followed by replacing the terms with CHV-preferred terms using the concept names and sources table (MRCONSO) in the Unified Medical Language System (UMLS) Metathesaurus. In the second stage, medical terms in the reports and general terms that are used to describe medical phenomena were selected and evaluated by comparing the words in the original reports with the translated ones. The evaluation includes measuring the content coverage, investigating lexical similarity, and finding trends in missing concepts. Of the 792 terms selected from the radiology reports, 695 of them could be mapped directly to CHV concepts, indicating a content coverage of 88.5%. A total of 51 of the concepts (53%, 51/97) that could not be mapped are names of human anatomical structures and regions, followed by 28 anatomical descriptions and pathological variations (29%, 28/97). In addition, 12 radiology techniques and projections represented

  11. Evaluation of droplet size distributions using univariate and multivariate approaches.

    Science.gov (United States)

    Gaunø, Mette Høg; Larsen, Crilles Casper; Vilhelmsen, Thomas; Møller-Sonnergaard, Jørn; Wittendorff, Jørgen; Rantanen, Jukka

    2013-01-01

    Pharmaceutically relevant material characteristics are often analyzed based on univariate descriptors instead of utilizing the whole information available in the full distribution. One example is droplet size distribution, which is often described by the median droplet size and the width of the distribution. The current study was aiming to compare univariate and multivariate approach in evaluating droplet size distributions. As a model system, the atomization of a coating solution from a two-fluid nozzle was investigated. The effect of three process parameters (concentration of ethyl cellulose in ethanol, atomizing air pressure, and flow rate of coating solution) on the droplet size and droplet size distribution using a full mixed factorial design was used. The droplet size produced by a two-fluid nozzle was measured by laser diffraction and reported as volume based size distribution. Investigation of loading and score plots from principal component analysis (PCA) revealed additional information on the droplet size distributions and it was possible to identify univariate statistics (volume median droplet size), which were similar, however, originating from varying droplet size distributions. The multivariate data analysis was proven to be an efficient tool for evaluating the full information contained in a distribution.

  12. Technical Efficiency Evaluation of Market Age and Enterprise Size ...

    African Journals Online (AJOL)

    Technical Efficiency Evaluation of Market Age and Enterprise Size for Broiler Production in Imo State, Nigeria. ... Open Access DOWNLOAD FULL TEXT Subscription ... Key words: Broiler Production, Technical Efficiency and Scale of Operation ...

  13. Case-oriented computer-based-training in radiology: concept, implementation and evaluation

    Science.gov (United States)

    Dugas, Martin; Trumm, Christoph; Stäbler, Axel; Pander, Ernst; Hundt, Walter; Scheidler, Jurgen; Brüning, Roland; Helmberger, Thomas; Waggershauser, Tobias; Matzko, Matthias; Reiser, Maximillian

    2001-01-01

    Background Providing high-quality clinical cases is important for teaching radiology. We developed, implemented and evaluated a program for a university hospital to support this task. Methods The system was built with Intranet technology and connected to the Picture Archiving and Communications System (PACS). It contains cases for every user group from students to attendants and is structured according to the ACR-code (American College of Radiology) [2]. Each department member was given an individual account, could gather his teaching cases and put the completed cases into the common database. Results During 18 months 583 cases containing 4136 images involving all radiological techniques were compiled and 350 cases put into the common case repository. Workflow integration as well as individual interest influenced the personal efforts to participate but an increasing number of cases and minor modifications of the program improved user acceptance continuously. 101 students went through an evaluation which showed a high level of acceptance and a special interest in elaborate documentation. Conclusion Electronic access to reference cases for all department members anytime anywhere is feasible. Critical success factors are workflow integration, reliability, efficient retrieval strategies and incentives for case authoring. PMID:11686856

  14. Case-oriented computer-based-training in radiology: concept, implementation and evaluation

    Directory of Open Access Journals (Sweden)

    Helmberger Thomas

    2001-10-01

    Full Text Available Abstract Background Providing high-quality clinical cases is important for teaching radiology. We developed, implemented and evaluated a program for a university hospital to support this task. Methods The system was built with Intranet technology and connected to the Picture Archiving and Communications System (PACS. It contains cases for every user group from students to attendants and is structured according to the ACR-code (American College of Radiology 2. Each department member was given an individual account, could gather his teaching cases and put the completed cases into the common database. Results During 18 months 583 cases containing 4136 images involving all radiological techniques were compiled and 350 cases put into the common case repository. Workflow integration as well as individual interest influenced the personal efforts to participate but an increasing number of cases and minor modifications of the program improved user acceptance continuously. 101 students went through an evaluation which showed a high level of acceptance and a special interest in elaborate documentation. Conclusion Electronic access to reference cases for all department members anytime anywhere is feasible. Critical success factors are workflow integration, reliability, efficient retrieval strategies and incentives for case authoring.

  15. Independent auto evaluation of an operative radiological protection program; Autoevaluacion independiente de un programa de proteccion radiologica operativa

    Energy Technology Data Exchange (ETDEWEB)

    Medrano L, M.A.; Rodriguez C, C.C.; Linares R, D.; Zarate M, N.; Zempoalteca B, R. [Gerencia Subsede Sureste Instituto Nacional de Investigaciones Nucleares, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: maam@nuclear.inin.mx

    2006-07-01

    The program of operative radiological protection of a nuclear power plant consists of multiple procedures and associate tasks that have as purpose the radiological protection of the workers of the power station. It is for this reason that the constant evaluation of the one it programs it is an important tool in the identification of their weaknesses (and strengths), so they can be assisted appropriately. In this work the main elements of the program of independent auto evaluation of the program of operative radiological protection of the Laguna Verde Central that has been developed and implemented by the National Institute of Nuclear Research are described. (Author)

  16. The clinical and radiological evaluation of absence of the corpus callosum

    International Nuclear Information System (INIS)

    Byrd, S.E.; Radkowski, M.A.; McLone, D.G.; Northwestern Univ., Chicago, IL; Flannery, A.

    1990-01-01

    A retrospective and prospective analysis of children with a diagnosis of complete absence of the corpus callosum (ACC) at the Children's Memorial Hospital in Chicago over a 5-year period was performed. The diagnosis was based on the computed tomography (CT) and/or magnetic resonance (MR) images. From this material, 105 children with a diagnosis of ACC were analyzed on the basis of clinical symptomatology and radiological studies (CT, MR and ultrasound). Eighty-three percent of our children were symptomatic. The most common symptoms and signs were macrocephaly with hydrocephalus and seizures. MR was the best radiological imaging modality for evaluating children with ACC and associated brain anomalies. The most common associated brain anomalies with ACC in decreasing frequency in our children were: interhemispheric cyst with hydrocephalus, Dandy-Walker malformation, migrational disorders, absence of the inferior vermis, cephaloceles and lipoma aof the interhemispheric fissure. (author). 15 refs.; 8 figs.; 2 tabs

  17. Determination and evaluation of the radiological situation using mobile measurements during the ground phase

    Energy Technology Data Exchange (ETDEWEB)

    Obrecht, R.; Pohl, H.; Schneider, S.; Grimm, C. [Umweltministerium Baden-Wuerttemberg, Stuttgart (Germany); Neff, Ulrich; Coutinho, Paula; Mueller, Ulrich; Mandel, Carmen [Landesanstalt fuer Umweltschutz, Messungen und Naturschutz Baden-Wuerttemberg, Karlsruhe (Germany); Wilbois, Thomas; Ren, Yongxiang [T-Systems GEI GmbH, Ulm (Germany); Chaves, Fernando [Fraunhofer Inst. IITB, Karlsruhe (Germany)

    2009-08-15

    The nuclear reactor remote monitoring system of the state of Baden-Wuerttemberg (Kernreaktor-Fernueberwachung Baden-Wuerttemberg - KFUeBW) is implemented according to the recently renewed ''recommendations for remote monitoring of nuclear power plants''. In Baden-Wuerttemberg, the application area of the system covers both, the surveillance of internal procedures on one hand, and the handling of incidents or accidents on the other. The following paper shows the role of the KFUeregarding the determination and evaluation of the radiological situation in the range of off-site emergency response. Progress is reported on the measurement conception and the technical possibilities for the investigation of the radiological situation after the end of the deposition of radio nuclides (ground phase). (orig.)

  18. Evaluation of the Internet precence of diagnostic radiology units at German universities

    International Nuclear Information System (INIS)

    Seitz, J.; Siegmund, M.; Voelk, M.; Feuerbach, S.; Strotzer, M.

    2002-01-01

    Purpose. Analyzing the availability and the contents of the internet homepages of the radiological departments of German universities.Material and method. In June and July 2001 the internet homepages of 36 radiological departments of German universities were evaluated in a study. A medical student experienced in using the world wide web examined the websites concerning the following criteria: research, teaching, informations for patients, clinical topics and general information. Additionally an evaluation of the technical standard of the presentation was performed.Results. 31 of the 36 radiological departments presented a homepage in the world wide web. The subject research was presented by 29 institutes. Also 29 departments provided information concerning teaching in their presentations. In 24 cases informations especially for patients were given. In all topics there is a huge variety of the quality and quantity of the provided information throughout the different institutions. 21 homepages available without restriction during the study period; 3 were nearly completely under construction. Multimedia techniques were only used in 2 homepages. The structural hierarchy of the webpages was in the average only two or three levels. Only 6 providers presented an additional version of their homepage in english.Conclusion. In the moment the possibility of internet-presentation is sub-optimal used by the responsible persons of the radiological institutions. The main emphasis is on research and teaching. There is nearly no use of multimedial elements in the presentations. Only a minority of the homepages can be read by international viewers because of the lack of an english version of the pages. (orig.) [de

  19. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  20. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  1. Potential release scenario and radiological consequence evaluation of mineral resources at WIPP

    International Nuclear Information System (INIS)

    Little, M.S.

    1982-05-01

    This report has reviewed certain of the natural resources which may be found at the site of the nuclear waste repository being considered for southeastern New Mexico, and discussed the scenarios which have been used to estimate the radiological consequences from the mining of these resources several hundred years after the radioactive waste has been emplaced. It has been concluded that the radiological consequences of the mining of potash or hydrocarbons (mostly natural gas) are probably bounded by the consequences of hydrologic breach scenarios already considered by the US Department of Energy, and by reports of EEG. These studies conclude that the resultant doses would not constitute a significant threat to public health. This report also evaluates the radiological consequences of solution mining of halite at the WIPP site. Although such mining in the Delaware Basin and particularly at the WIPP site, is not likely at the present time, significant economic, social or climatic changes a few hundred years after emplacement may make these resources more attractive. The DOE did not consider such mining at the site credible

  2. Evaluation of the level of skill required of operators of a computer-assisted radiologic total lung capacity measurement system

    International Nuclear Information System (INIS)

    Mazzeo, J.

    1985-01-01

    This research was conducted to obtain information regarding the feasibility of using non-medical personnel to obtain measurements of radiologic total lung capacity (TLC). Operators from each of four groups (general undergraduates, nursing students, medical students, radiologists) differing in the amount of medical training and/or experience reading x-rays, performed each of two tasks. The first task was the measurement of radiologic TLC for a set of twenty x-rays. The second task consisted of tracing the outline of the anatomical structures that must be identified in the execution of the radiologic TLC measurement task. Data from the radiologic TLC measurement task were used to identify possible group differences in the reliability and validity of the measures. The reliability analyses were performed within the framework of Generalizability Theory. While the results are not conclusive, due to small sizes, the analyses suggest that group differences in reliability of the measures, if they exist, are small

  3. Preparation, Conduct and Evaluation of Exercises to Test Preparedness for a Nuclear or Radiological Emergency

    International Nuclear Information System (INIS)

    2010-01-01

    The aim of this publication is to serve as a practical tool for the preparation, conduct and evaluation of exercises to test preparedness for response to a nuclear or radiological emergency. It fulfils in part the functions assigned to the IAEA under Article 5.a(ii) of the Convention on Assistance in Case of a Nuclear Accident or Radiological Emergency (Assistance Convention), namely, to collect and disseminate to States Parties and Member States information concerning the methodologies, techniques and available results of research on such emergencies. To ensure effective response to radiation emergencies when needed, provisions should be made for regular training of emergency response personnel. As stated in Preparedness and Response for a Nuclear or Radiological Emergency (Safety Requirements, Safety Standard Series No. GS-R-2), 'The operator and the response organizations shall make arrangements for the selection of personnel and training to ensure that the personnel have the requisite knowledge, skills, abilities, equipment, procedures and other arrangements to perform their assigned response functions'. A further requirement is that 'Exercise programmes shall be conducted to ensure that all specified functions required to be performed for emergency response and all organizational interfaces for facilities in threat category I, II or III and the national level programmes for threat category IV or V are tested at suitable intervals'. In 2004 the IAEA General Conference, in resolution GC(48)/RES/10 encouraged Member States to 'implement the Safety Requirements for Preparedness and Response to a Nuclear or Radiological Emergency'. This document is published as part of the IAEA Emergency Preparedness and Response Series to assist in meeting these requirements and to fulfil Article 5 of the Assistance Convention. It was developed based on a number of assumptions about national and local capabilities. Therefore, the exercise structure, terms and scenarios must be

  4. The radiological risks associated with the thorium fuelled HTGR fuel cycle. A comparative risk evaluation

    International Nuclear Information System (INIS)

    Dodd, D.H.; Hienen, J.F.A. van.

    1995-10-01

    This report presents the results of task B.3 of the 'Technology Assessment of the High Temperature Reactor' project. The objective of task B.3 was to evaluate the radiological risks to the general public associated with the sustainable HTGR cycle. Since the technologies to be used at several stages of this fuel cycle are still in the design phase and since a detailed specification of this fuel cycle has not yet been developed, the emphasis was on obtaining a global impression of the risk associated with a generic thorium-based HTGR fuel cycle. This impression was obtained by performing a comparative risk analysis on the basis of data given in the literature. As reference for the comparison a generic uranium fuelled LWR cycle was used. The major benefit with respect to the radiological rsiks of basing the fuel cycle around modular HTGR technology instead of the LWR technology is the increase in reactor safety. The design of the modular HTGR is expected to prevent the release of a significant amount of radioactive material to the environment, and hence early deaths in the surrounding population, during accident conditions. This implies that there is no group risk as defined in the Dutch risk management policy. The major benefit of thorium based fuel cycles over uranium based fuel cycles is the reduction in the radiological risks from unraium mining and milling. The other stages of the nuclear fuel cycle which make a significant contribution to the radiological risks are electricity generation, reprocessing and final disposal. The risks associated with the electricity generation stage are dominated by the risks from fission products, activated corrosion products and the activation products tritium and carbon-14. The risks associated with the reprocessing stage are determined by fission and activation products (including actinides). (orig./WL)

  5. The radiological risks associated with the thorium fuelled HTGR fuel cycle. A comparative risk evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dodd, D.H.; Hienen, J.F.A. van

    1995-10-01

    This report presents the results of task B.3 of the `Technology Assessment of the High Temperature Reactor` project. The objective of task B.3 was to evaluate the radiological risks to the general public associated with the sustainable HTGR cycle. Since the technologies to be used at several stages of this fuel cycle are still in the design phase and since a detailed specification of this fuel cycle has not yet been developed, the emphasis was on obtaining a global impression of the risk associated with a generic thorium-based HTGR fuel cycle. This impression was obtained by performing a comparative risk analysis on the basis of data given in the literature. As reference for the comparison a generic uranium fuelled LWR cycle was used. The major benefit with respect to the radiological rsiks of basing the fuel cycle around modular HTGR technology instead of the LWR technology is the increase in reactor safety. The design of the modular HTGR is expected to prevent the release of a significant amount of radioactive material to the environment, and hence early deaths in the surrounding population, during accident conditions. This implies that there is no group risk as defined in the Dutch risk management policy. The major benefit of thorium based fuel cycles over uranium based fuel cycles is the reduction in the radiological risks from unraium mining and milling. The other stages of the nuclear fuel cycle which make a significant contribution to the radiological risks are electricity generation, reprocessing and final disposal. The risks associated with the electricity generation stage are dominated by the risks from fission products, activated corrosion products and the activation products tritium and carbon-14. The risks associated with the reprocessing stage are determined by fission and activation products (including actinides). (orig./WL).

  6. Multimodal Dispersion of Nanoparticles: A Comprehensive Evaluation of Size Distribution with 9 Size Measurement Methods.

    Science.gov (United States)

    Varenne, Fanny; Makky, Ali; Gaucher-Delmas, Mireille; Violleau, Frédéric; Vauthier, Christine

    2016-05-01

    Evaluation of particle size distribution (PSD) of multimodal dispersion of nanoparticles is a difficult task due to inherent limitations of size measurement methods. The present work reports the evaluation of PSD of a dispersion of poly(isobutylcyanoacrylate) nanoparticles decorated with dextran known as multimodal and developed as nanomedecine. The nine methods used were classified as batch particle i.e. Static Light Scattering (SLS) and Dynamic Light Scattering (DLS), single particle i.e. Electron Microscopy (EM), Atomic Force Microscopy (AFM), Tunable Resistive Pulse Sensing (TRPS) and Nanoparticle Tracking Analysis (NTA) and separative particle i.e. Asymmetrical Flow Field-Flow Fractionation coupled with DLS (AsFlFFF) size measurement methods. The multimodal dispersion was identified using AFM, TRPS and NTA and results were consistent with those provided with the method based on a separation step prior to on-line size measurements. None of the light scattering batch methods could reveal the complexity of the PSD of the dispersion. Difference between PSD obtained from all size measurement methods tested suggested that study of the PSD of multimodal dispersion required to analyze samples by at least one of the single size particle measurement method or a method that uses a separation step prior PSD measurement.

  7. MR evaluation of postmenopausal ovarian size. Comparison with surgical specimen

    International Nuclear Information System (INIS)

    Joja, Ikuo; Ishida, Kana; Matsushita, Toshi; Mimura, Seiichi; Yamaguchi, Takuya; Akagi, Noriaki; Miyagi, Yasunari; Hara, Takeshi; Kanazawa, Susumu

    2008-01-01

    We investigated ovarian size after menopause using magnetic resonance (MR) imaging and gross specimens obtained from patients with uterine cancer after menopause in whom normal ovaries were confirmed at the time of surgery. The relationships between size of ovarian long axis and age, the number of years since menopause, and age at menopause were statistically evaluated for 130 ovaries observed in short-axis T 2 -weighted MR images of the uterine corpus and in 147 ovarian gross specimens. No significant relationships were found between size of ovarian long axis and these 3 factors. When the sizes of the ovaries in MR images were compared with those in gross specimens, the latter were larger, with a statistically significant difference. Similarly, when the sizes of the ovaries observed or not observed in MR images were compared in gross specimens, the former were larger, with a statistically significant difference. These results indicate that the size of the ovarian long axis observed in MR images does not accurately reflect the true size of the long axis, but ovarian size strongly affects visualization of the ovaries in MR images after menopause. In addition, these results indicate that there are no significant relationships between ovarian size after menopause and age, the number of years since menopause, or age at menopause. (author)

  8. Experiences from the evaluation of two global quality indicators in a radiology service

    International Nuclear Information System (INIS)

    Hernandez Lopez, L. Y.; Valdes Arce, Y.; Fleitas Estevez, I.

    2013-01-01

    The main objective in radiology is to obtain images of good quality for certain diagnosis, without unnecessarily irradiating the patient. This paper shows the results of the reject films and clinical image quality evaluations in the radiology service of the Hospital 'Abel Santamaria Cuadrado', Pinar del Rio, Cuba. Data were collected during March and September of 2012. Reject films analysis was done for conventional and mammography studies. Clinical image quality evaluated following the European Guidelines on Quality Criteria. The results show that reject films rate decreased from 6% on March to 1.3% on September, after applying corrective actions; while chests studies have the highest reject rate. The mean causes for rejections were maladjustments in the collimation system, equipment faults, sub exposure and overexposure. For mammography studies the initial reject rate was 29.3% and decreased to 5.9% on September. Mean causes for rejection were related to faults in the automatic processor and the mammography x-ray unit. Image quality also improved: only 48.3% of chest images and 10% of mammography images were considered to be acceptable for diagnosis at the first moment; while these percentages increased to 68.3% and 70% for chest and mammography studies, respectively in the September's evaluation. The study demonstrated that the frequently evaluation of the quality's indicators allows to identify the main causes of the image's detriment to propose corrective actions. Still in situations of insufficient resources it is possible to improve quality with simple interventions on the main faults detected. (Author)

  9. Evaluation of the radiological risk resulting from road transportation of tritiated water

    International Nuclear Information System (INIS)

    Menossi, C.A.; Segado, R.; Reyes, R.

    1983-01-01

    A probability model for the evaluation of the individual radiological risk resulting from road transportation of tritiated water in 200-liter drums is presented. In order to evaluate such risk, an evaluation must be made of the probability for an individual to be involved in the consequences of a radiological transport accident, to incur a given dose and to suffer deleterious effects resulting from the dose incurred. With the purpose of quantifying the importance of accidents, a severity level classification was adopted as a function of the fraction of liquid volume spilled as a result of the accident. Considering the above-mentioned severity classification and the transported volume, the volume and the spill area are implied, while the soil characteristics are taken into account. By evaluating the spill characteristics, the average meteorological conditions in the area under analysis and the activity concentration of the transported liquid, the activity concentration values for tritium in air may be estimated, thus allowing calculation of the effective dose equivalent to be incurred by the individual who is most exposed to the consequences of an associated event. As a result of the summarized analysis above, a value of the individual risk per unit of activity concentration is obtained for tritium and for a given volume of transported liquid. 8 references

  10. A pilot study to evaluate the use of virtual lectures for undergraduate radiology teaching

    Energy Technology Data Exchange (ETDEWEB)

    Sendra-Portero, Francisco, E-mail: sendra@uma.es [Departamento de Radiología y Medicina Física, Facultad de Medicina, Universidad de Málaga, Boulevar Louis Pasteur, 32, 29071 Málaga (Spain); Torales-Chaparro, Oscar E., E-mail: oetjft@terra.es [Departamento de Radiología y Medicina Física, Facultad de Medicina, Universidad de Málaga, Boulevar Louis Pasteur, 32, 29071 Málaga (Spain); Ruiz-Gómez, Miguel J., E-mail: mjrg@uma.es [Departamento de Radiología y Medicina Física, Facultad de Medicina, Universidad de Málaga, Boulevar Louis Pasteur, 32, 29071 Málaga (Spain); Martínez-Morillo, Manuel, E-mail: mmorillo@uma.es [Departamento de Radiología y Medicina Física, Facultad de Medicina, Universidad de Málaga, Boulevar Louis Pasteur, 32, 29071 Málaga (Spain)

    2013-05-15

    Purpose: To demonstrate that virtual lectures can substitute conventional lectures in radiology education for medical students. Methods and materials: During the course 2005–2006, 89 out from 191 (46.6%) third year students of a subject entitled “General Radiology”, participated voluntarily in a pilot study including 22 virtual lectures (Flash presentations translated from the same PowerPoint presentations of conventional lectures, adding recorded narration and navigation tools). Participants (P) studied by means of virtual lectures, while non-participants (NP) assisted to conventional lectures. The results of the final oral exam classified from 0 to 3, and a 60-questions evaluation on image interpretation were used to compare both groups after training. Finally, 34 students from the group P (38.2%) fulfilled a 10-points scale quality survey about the project. Results: Final exam qualifications were significantly higher for P than for NP (2.11 ± 0.85 versus 1.73 ± 1.04) as well as the number of correct answers of the evaluation on image interpretation (24.2 ± 6.2 versus 21.2 ± 5.4), but differences could obey to different attitudes between both groups. The usefulness of virtual lectures to learn General Radiology obtained the highest global scoring (8.82 ± 1.00). Contents were generally better evaluated than the design of the presentations. Conclusion: Virtual lectures can substitute conventional lectures in radiology education for medical students with no detriment to students’ learning. Their potential advantage is that magisterial lectures can be used to discuss contents with students in a more participative way if virtual lectures are provided before.

  11. A pilot study to evaluate the use of virtual lectures for undergraduate radiology teaching

    International Nuclear Information System (INIS)

    Sendra-Portero, Francisco; Torales-Chaparro, Oscar E.; Ruiz-Gómez, Miguel J.; Martínez-Morillo, Manuel

    2013-01-01

    Purpose: To demonstrate that virtual lectures can substitute conventional lectures in radiology education for medical students. Methods and materials: During the course 2005–2006, 89 out from 191 (46.6%) third year students of a subject entitled “General Radiology”, participated voluntarily in a pilot study including 22 virtual lectures (Flash presentations translated from the same PowerPoint presentations of conventional lectures, adding recorded narration and navigation tools). Participants (P) studied by means of virtual lectures, while non-participants (NP) assisted to conventional lectures. The results of the final oral exam classified from 0 to 3, and a 60-questions evaluation on image interpretation were used to compare both groups after training. Finally, 34 students from the group P (38.2%) fulfilled a 10-points scale quality survey about the project. Results: Final exam qualifications were significantly higher for P than for NP (2.11 ± 0.85 versus 1.73 ± 1.04) as well as the number of correct answers of the evaluation on image interpretation (24.2 ± 6.2 versus 21.2 ± 5.4), but differences could obey to different attitudes between both groups. The usefulness of virtual lectures to learn General Radiology obtained the highest global scoring (8.82 ± 1.00). Contents were generally better evaluated than the design of the presentations. Conclusion: Virtual lectures can substitute conventional lectures in radiology education for medical students with no detriment to students’ learning. Their potential advantage is that magisterial lectures can be used to discuss contents with students in a more participative way if virtual lectures are provided before

  12. The radiological evaluation of a prototype posting-in hatch under conditions of high alpha activity

    International Nuclear Information System (INIS)

    Smith, D.I.; Hollick, R.C.

    1987-07-01

    A prototype posting-in hatch, mounted vertically in the top panel of a highly active glovebox has been radiologically evaluated in the Fuels Laboratory, AEEW. This simple, air-lock type system of 100 mm diameter has pneumatically operated and interlocked lids and a low velocity, inward purge, supplied by the glovebox depression. The hatch proved extremely reliable and very easy to operate. More than 1200 simulated posting movements were carried out and a > 8 order of magnitude reduction in aerosol concentration was recorded from the active glovebox to the monitoring environment. (author)

  13. Normal radiological unossified hip joint space and femoral head size development during growth in 675 children and adolescents.

    Science.gov (United States)

    Wegener, Veronika; Jorysz, Gabriele; Arnoldi, Andreas; Utzschneider, Sandra; Wegener, Bernd; Jansson, Volkmar; Heimkes, Bernhard

    2017-03-01

    Evaluation of hip joint space width during child growth is important to aid in the early diagnosis of hip pathology in children. We established reference values for hip joint space and femoral head size for each age. Hip joint space development during growth was retrospectively investigated medial and cranial in 1350 hip joints of children using standard anteroposterior supine plain pelvic radiographs. Maximum capital femoral epiphysis diameter and femoral radii were further more investigated. Hip joint space values show a slow decline during growth. Joint space was statistically significantly (p < 0.006) larger in boys than girls. Our hip joint space measurements on supine subjects seem slightly larger than those reported by Hughes on standing subjects. Evaluation of the femoral head diameter and the radii showed a size curve quite parallel to the known body growth charts. Radii medial and perpendicular to the physis are not statistically significantly different. We recommend to compare measurements of hip joint space at two locations to age dependent charts using the same imaging technique. During growth, a divergence in femoral head size from the expected values or loss of the spherical shape should raise the question of hip disorder. Clin. Anat. 30:267-275, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. An evaluation of clinical, radiological and three-dimensional dental tomography findings in ectodermal dysplasia cases.

    Science.gov (United States)

    Doğan, Mehmet-Sinan; Callea, Michele; Yavuz, Ìzzet; Aksoy, Orhan; Clarich, Gabriella; Günay, Ayse; Günay, Ahmet; Güven, Sedat; Maglione, Michele; Akkuş, Zeki

    2015-05-01

    This study aimed to review the results related to head and jaw disorders in cases of ectodermal dysplasia. The evaluation of ectodermal dysplasia cases was made by clinical examination and examination of the jaw and facial areas radiologically and on cone-beam 3-dimensional dental tomography (CBCT) images. In the 36 cases evaluated in the study, typical clinical findings of pure hypohidrotic ectodermal displasia (HED) were seen, such as missing teeth, dry skin, hair and nail disorders. CBCT images were obtained from 12 of the 36 cases, aged 1.5- 45 years, and orthodontic analyses were made on these images. The clinical and radiological evaluations determined, hypodontia or oligodontia, breathing problems, sweating problems, a history of fever, sparse hair, saddle nose, skin peeling, hypopigmentation, hyperpigmentation, finger and nail deformities, conical teeth anomalies, abnormal tooth root formation, tooth resorption in the root, gingivitis, history of epilepsy, absent lachrymal canals and vision problems in the cases which included to the study. Ectodermal dysplasia cases have a particular place in dentistry and require a professional, multi-disciplinary approach in respect of the chewing function, orthognathic problems, growth, oral and dental health. It has been understood that with data obtained from modern technologies such as three-dimensional dental tomography and the treatments applied, the quality of life of these cases can be improved.

  15. Development and psychometric evaluation of the breast size satisfaction scale.

    Science.gov (United States)

    Pahlevan Sharif, Saeed

    2017-10-09

    Purpose The purpose of this paper is to develop and evaluate psychometrically an instrument named the Breast Size Satisfaction Scale (BSSS) to assess breast size satisfaction. Design/methodology/approach The present scale was developed using a set of 16 computer-generated 3D images of breasts to overcome some of the limitations of existing instruments. The images were presented to participants and they were asked to select the figure that most accurately depicted their actual breast size and the figure that most closely represented their ideal breast size. Breast size satisfaction was computed by subtracting the absolute value of the difference between ideal and actual perceived size from 16, such that higher values indicate greater breast size satisfaction. Findings Study 1 ( n=65 female undergraduate students) showed good test-retest reliability and study 2 ( n=1,000 Iranian women, aged 18 years and above) provided support for convergent validity using a nomological network approach. Originality/value The BSSS demonstrated good psychometric properties and thus can be used in future studies to assess breast size satisfaction among women.

  16. Designing an educational software for teaching and evaluation of radiology course in dentistry

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2009-08-01

    Full Text Available Background and purpose: Radiology course has different parts in dentistry curriculum in Iranian medical universities. The third part of this course involves the diagnosis of facial and jaw’s bone lesions. In this study an educational software was designed, by using Access Database Software, to teach this course to dentistry students and after one semester the efficacy of it was tested by examining the students’ opinion about it.Methods: In this study the radiology course part 3 was thought to the 32 students in 2 parts. In the first part (before mid-semester the traditional method of teaching and in the second part (after the mid-semester exam the designed software was used for teaching and evaluating the students. After each semester the opinion of the students about the course was examined by using a standard questionnaire. The students in the first and second part of the semester were considered as the control and case group respectively.Results: Most of the students (90.6% believe that the software is useful in education and helps them to learn the subject. In addition, 84.4% of students believe that the soft ware can evaluate the clinical skills of students in detecting the radiological lesions and that the program can save their studying time. Overall, the students’ marks in case group were significantly higher than these in control group. The overall satisfaction of 78.1% of students about this program was good while 9.3% did not have a good feeling about it and 12.5% did not express any opinion.Conclusion: This study shows the importance of using computer for educational purposes especially in the courses with a huge amount of materials to be memorized by students. Computer science can help students in memorizing different signs and symptoms of many disorders. In addition it can help the teachers to evaluate the students at the end of the course.Key words: Computer, Software, Education, Radiology, Dentistry.

  17. Dynamic size spectrometry of airborne microorganisms: Laboratory evaluation and calibration

    Science.gov (United States)

    Qian, Yinge; Willeke, Klaus; Ulevicius, Vidmantas; Grinshpun, Sergey A.; Donnelly, Jean

    Bioaerosol samplers need to be calibrated for the microorganisms of interest. The Aerosizer, a relatively new aerodynamic size spectrometer, is shown to be a suitable dynamic instrument for the evaluation and calibration of such samplers in the laboratory, prior to their use in the field. It provides the necessary reference count against which the microbiological response of the sampler can be compared. It measures the health-significant aerodynamic diameters of microorganisms down to 0.5 μm, thus including most of the bacteria, fungi and pollen found in outdoor and indoor air environments. Comparison tests with a laser size spectrometer indicate that the suspension of microorganisms needs to be washed several times before aerosolization to avoid coating of the airborne microorganisms with nutrients and microbial slime from the suspension, and to reduce the residue particles to sizes below the lowest size of the aerosolized microorganisms.

  18. Background radon levels in Germany and how to take them into account in radiological evaluations

    International Nuclear Information System (INIS)

    Gehrcke, K.; Kuemmel, M.; Dushe, C.

    2008-01-01

    A mean background radon level of 9 ±, 1 Bq/m 3 was determined for Germany as a whole. This value is lower by about 5 Bq/m3 compared to previous, less representative measurements. For 17 former mining areas in the east of Germany representative regional background levels were derived. Characteristic limits (decision thresholds and detection limits) were determined for these areas to facilitate statistically sound decisions in the radiological evaluation of mining legacies. The detection limits for the anthropogenic contribution to the radon concentration vary from 10 to more than 20 Bq/m 3 in the different mining areas. Especially the higher values are governed by the spatial and temporal variability of the background concentrations rather than measurement uncertainties. The fact that man-made contributions of partly more than 20 Bq/m3 cannot be detected with sufficient statistical accuracy has to be taken into account in radiological investigations and evaluations of mining legacies. (author)(tk)

  19. Radiological safety evaluation for a Waste Transfer Facility at Savannah River Site

    International Nuclear Information System (INIS)

    Ades, M.J.

    1993-01-01

    This paper provides a review of the radiological safety evaluation performed for a Waste Transfer Facility (WTF) located at the Savannah River Site (SRS). This facility transfers liquid radioactive waste between various waste processing facilities and waste storage facilities. The WTF includes functional components such as the diversion box and the pump pits, waste transfer lines, and the outside yard service piping and electrical services. The WSRC methodology is used to evaluate the consequences of postulated accidents that result in the release of radioactive material. Such accidents include transfer line breaks, underground liquid pathway release, fire in pump tank cells and HEPA filters, accidents due to natural phenomena, and externally induced events. Chemical hazards accidents are not considered. The analysis results indicate that the calculated mean onsite and offsite radiological consequences are bounded by the corresponding WSRC dose limits for each accident considered. Moreover, the results show that the maximum onsite and offsite doses calculated for the WTF are lower than the maximum doses determined for the whole radioactive waste facility where the WTF is located

  20. Evaluation of radiological protection and dose of skin entrance in paediatric dentistry examinations

    International Nuclear Information System (INIS)

    Khoury, Helen Jamil; Silveira, Marcia Maria Fonseca da; Couto, Geraldo Bosco Lindoso; Brasileiro, Izabela Vanderley

    2005-01-01

    In this work the radiological protection conditions and dose at the entrance of pediatric patients undergoing dental intraoral radiographs were evaluated. The study was conducted in two clinics of the dentistry course at the Federal University of Pernambuco, Recife, PB, Brazil, equipped with conventional X-ray apparatus, with 60 and 70 kV. 254 exams of 113 patients between the ages of 3 to 12 years were evaluated. The skin entrance dose was estimated using TLD-100 thermoluminescent dosemeters. During the examination were also recorded information regarding the time of exposure, radiographic technique used, use of thyroid protectors and lead apron, angle and distance of the cone Locator to the patient's skin. The results showed that the input skin doses ranged from 0.3 mGy to 10mGy. The lead apron was used in 71% of exams while the thyroid shield was only used in 58% of the exams. The exposure times ranged from 0,5s to 1,5s. From the results it can be concluded that the radiological procedures are not optimized and that in some cases the patient dose is high.

  1. Design evaluation of the HTGR fuel element size reduction system

    International Nuclear Information System (INIS)

    Strand, J.B.

    1978-06-01

    A fuel element size reduction system for the ''cold'' pilot plant of the General Atomic HTGR Reference Recycle Facility has been designed and tested. This report is both an evaluation of the design based on results of initial tests and a description of those designs which require completion or modification for hot cell use. 11 figures

  2. Firm Size, Ownership, Training Duration and Training Evaluation Practices

    Science.gov (United States)

    Asadullah, Muhammad Ali; Peretti, Jean Marie; Ali, Arain Ghulam; Bourgain, Marina

    2015-01-01

    Purpose: The purpose of this paper was to test the mediating role of training duration in relationship between firm characteristics and training evaluation practices. In this paper, the authors also investigated if this mediating effect differs with respect to the size of the firm. Design/methodology/approach: The authors collected data from 260…

  3. Radiological Characteristics and Anatomical Risk Factors in the Evaluation of Hallux Valgus in Chinese Adults

    Science.gov (United States)

    Xu, Hailin; Jin, Kaiji; Fu, Zhongguo; Ma, Mingtai; Liu, Zhongdi; An, Shuai; Jiang, Baoguo

    2015-01-01

    Background: There are no unified theories as to the anatomical changes that occur with hallux valgus, we investigated the radiological characteristics and anatomical risk factors for hallux valgus deformity in Chinese adults. Methods: We reviewed 141 patients with hallux valgus (206 feet; 15 males, 126 females; mean age, 58.5 years). These patients attended Peking University People's Hospital from April 2008 to March 2014. All feet had intact radiological data, obtained using the Centricity RIS/PACS system. We measured hallux valgus angle (HVA), 1–2 intermetatarsal angle (IMA), proximal articular set angle (PASA), distal articular set angle, hallux interphalangeal angle, metatarsocuneiform angle, size of the medial eminence of the distal first metatarsal, tibial sesamoid position, and joint congruity of the first metatarsophalangeal joint (MTPJ). Results: We found positive correlations between the HVA and IMA (r = 0.279, P 0.05). Feet were divided into three groups based on HVA severity. IMA (P 0.05). Feet were then grouped based on the shape of the first metatarsal head. Using this grouping, HVA was significant higher in the rounded shape (19.92°) than in a flat shape (17.66°). The size of the medial eminence of the distal first metatarsal was positively correlated with HVA (r = 0.185, P hallux valgus formation, and decompensation leads to subdislocation in the first MTPJ. A rounded first metatarsal head would thus predispose a foot to hallux valgus. Furthermore, bone proliferation at the medial eminence may also lead to early hallux valgus development. PMID:25563313

  4. Radiological Characteristics and Anatomical Risk Factors in the Evaluation of Hallux Valgus in Chinese Adults

    Directory of Open Access Journals (Sweden)

    Hailin Xu

    2015-01-01

    Full Text Available Background: There are no unified theories as to the anatomical changes that occur with hallux valgus, we investigated the radiological characteristics and anatomical risk factors for hallux valgus deformity in Chinese adults. Methods: We reviewed 141 patients with hallux valgus (206 feet; 15 males, 126 females; mean age, 58.5 years. These patients attended Peking University People′s Hospital from April 2008 to March 2014. All feet had intact radiological data, obtained using the Centricity RIS/PACS system. We measured hallux valgus angle (HVA, 1-2 intermetatarsal angle (IMA, proximal articular set angle (PASA, distal articular set angle, hallux interphalangeal angle, metatarsocuneiform angle, size of the medial eminence of the distal first metatarsal, tibial sesamoid position, and joint congruity of the first metatarsophalangeal joint (MTPJ. Results: We found positive correlations between the HVA and IMA (r = 0.279, P 0.05. Feet were divided into three groups based on HVA severity. IMA (P 0.05. Feet were then grouped based on the shape of the first metatarsal head. Using this grouping, HVA was significant higher in the rounded shape (19.92° than in a flat shape (17.66°. The size of the medial eminence of the distal first metatarsal was positively correlated with HVA (r = 0.185, P < 0.01. The medial eminence in the moderate and severe groups was significantly larger than that in the mild group; moderate and severe groups were not significantly different. Conclusions: PASA enlargement is an adaptive change during early hallux valgus formation, and decompensation leads to subdislocation in the first MTPJ. A rounded first metatarsal head would thus predispose a foot to hallux valgus. Furthermore, bone proliferation at the medial eminence may also lead to early hallux valgus development.

  5. Cost-benefit evaluation of systematic radiological diagnosis of congenital dislocated hip

    International Nuclear Information System (INIS)

    Faure, C.; Schmit, P.; Salvat, D.

    1984-01-01

    The interest of radiological mass screening of congential dislocated hip is still debated. We have tried to evaluate the cost-benefit ratio of radiological detection at the age of 3-4 months, taking into account the socio-economic cost and radiation risk. Assuming a frequency of this disorder of 1% the average cost of treatment of one case detected by X-ray screening at the age of 3-4 months, including the price of X-ray examinations of 99 normal babies is 23.374 FF. The average cost of treatment of a case detected at walking-age, i.e. after 9 months, is 84.230 FF. The cost-benefit ratio is 3.6. In countries where the frequency reaches 2% the cost benefit ratio is 4.57. It also appears from our study that the irradiation of the patient is much smaller when the diagnosis is made earlier. Comparing the slight irradiation delivered to normal infants by this mass screening to the heavy irradiation received by a few individuals whose treatment is started after 9 months, the calculated risk of leukemia or of genetic disorder for the whole population still favours a systematic X-ray film of the pelvis at age 3-4 months. However, if it were decided to make obligatory this mass radiological detection programme during the fourth month of life, this would necessitate a serious effort to train all radiologists to obtain adequate films with the best radiation protection. (orig.)

  6. Evaluation of patient radiation doses using DAP meter in interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Sam [Dept. of Radiological Technology. Shingu University, Sungnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu Univeristy, Kyushu (Japan)

    2017-03-15

    The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipment in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effective of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were 237.7 Gy·cm{sup 2} in TACE, 17.3 Gy·cm{sup 2} in AVF, 114.1 Gy·cm{sup 2} in LE PTA and STENT, 188.5 Gy·cm{sup 2} in TFCA, 383.5 Gy·cm{sup 2} in Aneurysm Coil, 64.6 Gy·cm{sup 2} in PTBD, 64.6 Gy·cm{sup 2} in Biliary Stent, 22.4 Gy·cm{sup 2} in PCN, 4.3 Gy·cm{sup 2} in Hickman, 2.8 Gy·cm{sup 2} in Chemo-port, 4.4 Gy·cm{sup 2} in Perm-Cather, 17.1 Gy·cm{sup 2} in PCD, and 357.9 Gy·cm{sup 2} in Vis, EMB. Dose reference level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipment and procedures in the interventional radiology procedures, further studies and monitoring are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

  7. Evaluation of the initial and final radiological status of a nuclear facility in sanitation status

    International Nuclear Information System (INIS)

    Granier, Guy; Aubonnet, Emilie; Courbet, Christele; Desnoyers, Yvon; Dubot, Didier; Fichet, Pascal; Nokhamzon, Jean-Guy; Ollivier Dehaye, Catherine; Pillette-Cousin, Lucien; Mahe, Charly

    2017-02-01

    This technical report is a guideline for radiological assessment of a nuclear facility in remediation stages. From initial state of remediation to final status survey it describes the best suited statistical or geostatistical approach for the characterization of sites contaminated by radionuclides. Prior to any characterization campaign an historical analysis coupled with a function analysis targeted investigations is fundamental to obtain a robust overview. The evaluation of the amount of radioactive material present in a defined area requires a sampling strategy correlated with characterization objective. On the other hand correlation between remediation objectives and characterization objectives also requires knowing acceptable level of risk. This give better inputs to allow available resources and take into account environmental constraints. In particular, radiological characterization of infrastructures is one of the key step to conduct industrial project of decommissioning nuclear facilities in remediation. It needs a reliable initial diagnosis to obtain an efficient waste management with a financial control Optimization of the production of nuclear waste. It is an important part of Setting the Off Final - Dismantling). This approach is compatible with French Regulation (Guide 14 ASN) for the first and second line of defence. Annexes provide feedback of experimentation of this methodology. This report supplements the methodological guide published by the GT10 CETAMA entitled 'Soil Radiological Characterisation Methodology' (CEA-R 6386). The latter is intended for project managers and covers all issues related to the characterization projects for soil. This guideline concern specifically design engineers in charge of implementation program at the different stages of investigation and data processing. Similarly, the proposed methodology can be broken for the characterization of chemical pollution and process equipment. (authors)

  8. Evaluation of skin entry kerma in radiological examinations at the Hospital de Clinicas, Parana, Brazil

    International Nuclear Information System (INIS)

    Porto, Lorena E.; Schelin, Hugo R.; Santos, Amanda C. dos; Bunick, Ana Paula; Paschuk, Sergei; Denyak, Valeriy; Tilly Junior, Joao G.; Khoury, Helen J.

    2011-01-01

    This paper evaluates the skin entry dose of pediatric and adults patients when submitted to radiological examinations at the Hospital de Clinicas do Parana, Brazil, as part integrate of the data assessment of International Atomic Energy Agency (IAEA) for Latin America. It was performed measurements of dose for evaluation of skin entry kerma in pediatric patients in thorax AP/PA examinations, adults of thorax in AP/PA, cranio caudal mammography and median lateral and patients of computerized tomography in examination of head, thorax and abdomen. The obtained data demonstrate the necessity of verification of diagnostic analysis standards. The great value amplitudes demonstrate the incompatibility of examination executions with those recommended by the literature. The dose values presented partially inside the range recommended and the other over the expected for the due examination when compared with the literature

  9. RASCAL 4.l: evaluation system for the analysis of the radiological consequences

    International Nuclear Information System (INIS)

    Miguel, I. de; Gomez-Arguello, B.

    2012-01-01

    Recently the Spanish Nuclear Safety Council (CSN) has promoted the replacement of the code used in the Spanish Nuclear Power Plants to estimate potential and actual doses due to atmospheric releases. IRDAM Code (interactive Rapid Dose Assessment Model, 1983) by RASCAL Code version 4.1 (Radiological Assessment System for consequence Analysis). This code was developed by the NRC (Nuclear Regulatory Commission) to evaluate releases from nuclear power plants, spent fuel storage pools and casks, fuel cycle facilities and radioactive material handling facilities. RASCAL was officially requested to the Spanish nuclear power plants in February 1st, 2012, and it can be used for external dose assessment and to evaluate the recommended protective action for the public in a specific situation (sheltering, prophylaxis, evacuation, etc.). (Author)

  10. The First Report on Evaluating the Thoracic Radiology of the Medical Institutions for Pneumoconiosis in Korea

    International Nuclear Information System (INIS)

    Lee, Won Jeong; Chu, Sang Deok; Park, So Young; Choi, Byung Soon; Park, Jai Soung; Kim, Sung Jin; Ko, Kyung Sun

    2010-01-01

    The pnuemoconiotic findings on chest radiograph for pneumoconiosis are affected by the technique, the equipment and the reading environment. We report here on the results of evaluating the thoracic radiology of the Medical Institutions for Pneumoconiosis (MIPs). For the first time, we visited the MIPs to evaluate the thoracic radiography that is used to treat patients with pneumoconiotic complications, and this included evaluating the equipment and the technical parameters for thoracic radiography, the computed tomography, the education for quality assurance health care and the reading environment. We used the guideline published by the Occupational Safety and Health Research Institute (OSHRI). Ten images were randomly picked from the MIPs for evaluating the image quality, and then these were rated by two experienced chest radiologists for pneumoconiosis according to the criteria of the OSHRI. Of the 33 institutions, the failed group (mean<60) scored 36.4% for radiological technique (RT), 30.3% for image quality (IQ) and 21.2% for the reading environment (RE). There were statistically significantly differences between the passed and failed groups for RT (75.8 ± 9.1 vs. 40.8 ± 13.6, p<0.001), for IQ (68.3 ± 5.8 vs. 47.8 ± 9.4, p<0.001) and for RE (78.3 ± 15.8 vs. 18.3 ± 21.9, p<0.001). The group that received education was significantly higher for the RT (68.7 vs. 53.2, p=0.032), the IQ (65.3 vs. 56.6, p=0.039) and the RE (76.2 vs. 47.0, p=0.005) than that for the group that didn't receive education. The MIPs need surveillance and education for improving the quality assurance health care in thoracic radiography for treating patients with pneumoconiosis and who have complications

  11. Latest 'evaluation of size of economy' for nuclear uses

    International Nuclear Information System (INIS)

    Saito, Shinzo; Kume, Tamikazu; Inoue, Tomio; Takahashi, Shoji

    2008-01-01

    Size of economy for nuclear uses in Japan was evaluated for FY 2005. Nuclear uses are classified into nuclear energy use and radiation utilizations. Nuclear energy use totaled 4.7 trillion yen with nuclear power. Economy size of nuclear power decreased due to disgraceful events and accidents, though 5.5 trillion yen around for FY 2000. Radiation utilizations totaled 4.1 trillion yen mainly with industrial uses (2.3 trillion yen) and nuclear medicine, diagnosis and radiotherapy (1.5 trillion yen). Combined total of uses amounted to 8.9 trillion yen and comparable with 9.5 trillion yen for FY 1997. (T. Tanaka)

  12. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    International Nuclear Information System (INIS)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416±45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency

  13. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo [Kyunghee University Hospital, seoul (Korea, Republic of)

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416{+-}45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency.

  14. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)

    2017-10-15

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  15. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong

    2017-01-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  16. Evaluation of Case Size 0603 BME Ceramic Capacitors

    Science.gov (United States)

    Teverovsky, Alexander A.

    2015-01-01

    High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

  17. Radiological consequence analyses of loss of coolant accidents of various break sizes of Pressurized Heavy Water Reactor

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Hari Prasad, M.; Ghosh, A.K.

    2010-01-01

    For any advanced technology, it is essential to ensure that the consequences associated with the accident sequences arising, if any, from the operation of the plant are as low as possible and certainly below the guidelines/limits set by the regulatory bodies. Nuclear power is no exception to this. In this paper consequences of the events arising from Loss of Coolant Accident (LOCA) sequences in Pressurized Heavy Water Reactor (PHWR), are analysed. The sequences correspond to different break sizes of LOCA followed by the operation or otherwise of Emergency Core Cooling System (ECCS). Operation or otherwise of the containment safety systems has also been considered. It has been found that there are no releases to the environment when ECCS is available. The releases, when ECCS is not available, arise from the slack and the ground. The radionuclides considered include noble gases, iodine, and cesium. The hourly meteorological parameters (wind speed, wind direction, precipitation and stability category), considered for this study, correspond to those of Kakrapar site. The consequences evaluated are the thyroid dose and the bone marrow dose received by a person located at various distances from the release point. Isodose curves are generated. From these evaluations, it has been found that the doses are very low. The complementary cumulative frequency distributions (CCFD) for thyroid and bone marrow doses have also been presented for the cases analysed. (author)

  18. Radiological health risk evaluation of radium contaminated land: A real life implementation

    International Nuclear Information System (INIS)

    Paridaens, J.

    2005-01-01

    A plot of land, currently used for dairy farming, has been contaminated over the years with radium due to the operation of one of the world's largest radium production plants. Within the framework of a global remediation approach for the plant surroundings, the land owner needed advice for a future destination of the land. Therefore, the radium contamination was accurately mapped, and on the basis of its severity a practically feasible subdivision of the land into four plots was proposed. For all four plots, the radiological risk was evaluated for the current type of land use and for possible alternative types. Hence a clear and usable advice could be formulated to the authorities reconciling public health, economic and practical issues. (authors)

  19. Evaluation of the Radiological Safety of 192 Ir Apparatus for Industrial Gamma Radiography

    International Nuclear Information System (INIS)

    Aquino, J. O.; Silva, F. C. A. da; Ramalho, A. T.; Godoy, J. M. O.

    2004-01-01

    The majority of the 192Ir apparatus for industrial gamma radiography have been in usage in Brazil for more than 20 years. They are portable, and almost all operate according to category II. The main objective of this work was to assess the radiological safety of the 11 models of 192Ir apparatus most used in Brazil. The 11 models of 192Ir apparatus were studied with respect to compliance with the main safety requirements of three editions of international Standards ISO 3999. Six models were already manufactured incorporating the safety devices specified in the first edition of ISO 3999, issued in 1977. However, five models were not. The validity of their type B certificates for transport packages was also evaluated. (Author) 8 refs

  20. Radioactive lightning rods: radiologic evaluation and regulatory policy related to its use in Cuba

    International Nuclear Information System (INIS)

    Lopez Forteza, Yamil; Quevedo Garcia, Jose R.; Diaz Guerra, Pedro I.; Cruz Dumenico, Gonzalez; Fuente Puch, Andres de la

    2001-01-01

    The radioactive lightning rod employment for the protection of facilities against atmospheric discharges reached its maximum splendor in the eighties. It was in fact at the end of this decade when the technical considerations related to the justification of this practice finally conclude that the production of such teams was abolished. For the regulatory authorities, however, it continues having validity the question related to the control of lightning rod still in use as well as the question related to the establishment of a coherent with the international practice national policy. The paper shows the results of the last 10 years of control of the radioactive lightning rod use in Cuba and the radiological evaluation carried out on the base of this experience. Lastly, it exposes the regulatory policy referred to the employment of the radioactive lightning rod in the country. (author)

  1. On-field evaluation of operator lens protective devices in interventional radiology

    International Nuclear Information System (INIS)

    Strocchi, S.; Chiaravalli, A.; Veronese, I.; Novario, R.

    2016-01-01

    The recent publication of the Euratom Directive 2013/59, adopting the reduction of eye lens dose limits from 150 to 20 mSv y"-"1, calls for the development of new tools and methodologies for evaluating the eye lens dose absorbed by the medical staff involved in interventional radiology practices. Moreover, the effectiveness of the protective devices, like leaded glasses, which can be employed for radiation protection purposes, must be tested under typical exposure scenarios. In this work, eye lens dose measurements were carried out on an anthropomorphic phantom simulating a physician bound to perform standard interventional neuroradiology angiographic procedures. The correlation between eye lens doses, in terms of Hp(0.07), and the equivalent dose [again in terms of Hp(0.07)] monthly measured with thermoluminescent dosemeters placed above the lead apron at the chest level was studied, in the presence and in the absence of different types of leaded glasses. (authors)

  2. An evaluation of the chemical, radiological, and ecological conditions of West Lake on the Hanford site

    Energy Technology Data Exchange (ETDEWEB)

    Poston, T.M.; Price, K.L.; Newcomer, D.R.

    1991-03-01

    West Lake and its immediate surrounding basin represent a unique habitat that is dominated by highly saline water and soil. The basin offers a valuable research site for studies of a rare and complex wetland area in the desert. This report is an evaluation of the chemical, radiological, and ecological conditions at West Lake and describes how ground water influences site properties. The scope of this evaluation consisted of a sampling program in 1989 and a review of data from the perspective of assessing the impact of Hanford Site operations on the physical, chemical, and ecological conditions of West Lake and its surrounding basin. The water level in West Lake fluctuates in relation to changes in the water table. The connection between West Lake and ground water is also supported by the presence of {sup 3}H and {sup 99}Tc in the ground water and in the lake. There are relatively high concentrations of uranium in West Lake; the highest concentrations are found in the northernmost isolated pool. Analyses of water, sediment, vegetation, and soil indicate possible shifts of isotropic ratios that indicate a reduction of {sup 235}U. Uranium-236 was not detected in West Lake water; its presence would indicate neutron-activated {sup 235}U from fuel reprocessing at Hanford. Trace metals are found at elevated concentrations in West Lake. Arsenic, chromium, copper, and zinc were found at levels in excess of US Environmental Protection Agency water quality criteria. Levels of radiological and chemical contamination in the West Lake basin are relatively low. Concentrations of fission isotopes exceed those that could be explained by atmospheric fallout, but fall short of action levels for active waste management areas. 31 refs., 8 figs., 18 tabs.

  3. An evaluation of the chemical, radiological, and ecological conditions of West Lake on the Hanford site

    International Nuclear Information System (INIS)

    Poston, T.M.; Price, K.L.; Newcomer, D.R.

    1991-03-01

    West Lake and its immediate surrounding basin represent a unique habitat that is dominated by highly saline water and soil. The basin offers a valuable research site for studies of a rare and complex wetland area in the desert. This report is an evaluation of the chemical, radiological, and ecological conditions at West Lake and describes how ground water influences site properties. The scope of this evaluation consisted of a sampling program in 1989 and a review of data from the perspective of assessing the impact of Hanford Site operations on the physical, chemical, and ecological conditions of West Lake and its surrounding basin. The water level in West Lake fluctuates in relation to changes in the water table. The connection between West Lake and ground water is also supported by the presence of 3 H and 99 Tc in the ground water and in the lake. There are relatively high concentrations of uranium in West Lake; the highest concentrations are found in the northernmost isolated pool. Analyses of water, sediment, vegetation, and soil indicate possible shifts of isotropic ratios that indicate a reduction of 235 U. Uranium-236 was not detected in West Lake water; its presence would indicate neutron-activated 235 U from fuel reprocessing at Hanford. Trace metals are found at elevated concentrations in West Lake. Arsenic, chromium, copper, and zinc were found at levels in excess of US Environmental Protection Agency water quality criteria. Levels of radiological and chemical contamination in the West Lake basin are relatively low. Concentrations of fission isotopes exceed those that could be explained by atmospheric fallout, but fall short of action levels for active waste management areas. 31 refs., 8 figs., 18 tabs

  4. Evaluation of the radiological consequences of a human intrusion in a granite formation

    International Nuclear Information System (INIS)

    Mejon-Goula, M.J.; Cernes, A.

    1989-07-01

    The methodology used in France for the evaluation of the radiological consequences associated to a nuclear waste repository in a deep geological formation is the deterministic one. This means that, in addition to the calculations in connection with the ''normal'' scenario, a limited number of ''altered'' scenarios, representing the different families of plausible scenarios and corresponding to the most important consequences resulting from there families, have to be taken into account. Among them, the human intrusion scenario is an important one. In a study performed inside the CEC PAGIS project and also for a french expert group (Goguel group) which carried out a methodologic work for the national site selection procedure, results concerning the quantification of the radiological consequences of a human intrusion have been obtained without attempting at the evaluation of its probability. The intrusion time ranged from 1 000 to 100 000 years and different contamination scenarios were taken into account. It was assumed that the intrusion led to the creation of a 100 cubic meters edge cubic cavity in the immediate vicinity to the repository. Using the description of the Auriat site realized for PAGIS, the calculation was performed in three steps: - calculation of the evolution of the repository until the intrusion time, - computation of the supposed instantaneous new flow distribution after the intrusion, - computation of the dose rate, using the mean volumic activity in the cavity walls and the outgoing flow rate. Three exposure scenarios were considered: - a worker in the mine exposed to by external irradiation and contaminated by inhalation of radioactive materials, -an animal drinking in the vicinity during the mining operation, - gardening after the closure of the mine. With the exception of the worker scenario (the dose rate may reach 10 -2 Sv/year, which is comparable with the normal exposure in a granite mine), the other dose rates were found to be quite low

  5. Cytotoxicity evaluation of ceramic particles of different sizes and shapes.

    Science.gov (United States)

    Yamamoto, Akiko; Honma, Rieko; Sumita, Masae; Hanawa, Takao

    2004-02-01

    When artificial hip or knee joints are implanted in the human body, they release metallic, ceramic, and polymeric debris into the surrounding tissues. The toxicity of the released particles is of two types: chemical, caused by the released soluble ions and monomers, and mechanical, a result of mechanical stimulation produced by the insoluble particles. In this study, the cytotoxicity of particles of TiO2, Al2O3, ZrO2, Si3N4, and SiC for murine fibroblasts and macrophages were examined to evaluate just their mechanical toxicity because these particles are not expected to release soluble metal ions. Different sizes and shapes of TiO2 particles were used to evaluate the effect of size and shape on particle cytotoxicity. The results suggest that the cytotoxicity of ceramic particles does not depend on their chemical species. Cytotoxicity levels were lower than those of corresponding metal ions, indicating that the mechanical toxicity of particles is lower than the chemical toxicity of released soluble ions and monomers. The differences in size did not affect the mechanical toxicity of these particles. The dendritic particles had a higher cytotoxicity level for macrophages than did spindle and spheric particles. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 244-256, 2004

  6. Evaluation of the non-radiological environmental problems relating to the WIPP

    International Nuclear Information System (INIS)

    Baca, T.E.

    1983-02-01

    The major non-radiological environmental problems addressed are: air pollution, water pollution and sanitary waste, solid waste, domestic drinking water, occupational health and safety and toxic chemicals

  7. Geostatistical methods for radiological evaluation and risk analysis of contaminated premises

    International Nuclear Information System (INIS)

    Desnoyers, Y.; Jeannee, N.; Chiles, J.P.; Dubot, D.

    2009-01-01

    Full text: At the end of process equipment dismantling, the complete decontamination of nuclear facilities requires the radiological assessment of residual activity levels of building structures. As stated by the IAEA, 'Segregation and characterization of contaminated materials are the key elements of waste minimization'. From this point of view, the set up of an appropriate evaluation methodology is of primordial importance. The radiological characterization of contaminated premises can be divided into three steps. First, the most exhaustive facility analysis provides historical, functional and qualitative information. Then, a systematic (exhaustive or not) control of the emergent signal is performed by means of in situ measurement methods such as surface control device combined with in situ gamma spectrometry. Besides, in order to assess the contamination depth, samples can be collected from boreholes at several locations within the premises and analyzed. Combined with historical information and emergent signal maps, such data improve and reinforce the preliminary waste zoning. In order to provide reliable estimates while avoiding supplementary investigation costs, there is therefore a crucial need for sampling optimization methods together with appropriate data processing techniques. The relevance of the geostatistical methodology relies on the presence of a spatial continuity for radiological contamination. In this case, geostatistics provides reliable methods for activity estimation, uncertainty quantification and risk analysis, which are essential decision-making tools for decommissioning and dismantling projects of nuclear installations. Besides, the ability of this geostatistical framework to provide answers to several key issues that generally occur during the clean-up preparation phase is discussed: How to optimise the investigation costs? How to deal with data quality issues? How to consistently take into account auxiliary information such as historical

  8. Fire victim identification by post-mortem dental CT: Radiologic evaluation of restorative materials after exposure to high temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Woisetschlaeger, Mischa, E-mail: Mischa.woisetschlager@lio.se [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Lussi, Adrian, E-mail: anders.persson@cmiv.lio.se [Department of Preventive, Restorative and Pediatric Dentistry, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern (Switzerland); Persson, Anders, E-mail: adrian.lussi@zmk.unibe.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Jackowski, Christian, E-mail: christian.jackowski@irm.uzh.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Institute of Legal Medicine, University of Zuerich, Winterthurerstrasse 190/52, 8057 Zuerich (Switzerland)

    2011-11-15

    Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures {>=}400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.

  9. Fire victim identification by post-mortem dental CT: Radiologic evaluation of restorative materials after exposure to high temperatures

    International Nuclear Information System (INIS)

    Woisetschlaeger, Mischa; Lussi, Adrian; Persson, Anders; Jackowski, Christian

    2011-01-01

    Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures ≥400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.

  10. Rade-aid a decision support system to evaluate countermeasures after a radiological accident

    International Nuclear Information System (INIS)

    Wagenaar, G.; Van Den Bosch, C.J.H.; Weger, D. de.

    1990-01-01

    After Chernobyl the authorities in many countries were overwhelmed by the enormous amount of information that was being generated by measuring and monitoring programs. In making decisions, this information had to be combined with the results of specific countermeasures, in order to determine the optimal strategy with respect to a large number of consequences. The development of RADE-AID, the Radiological Accident Decision AIDing system, is aimed at providing a powerful tool in the decision-making process. RADE-AID is developed by TNO (The Netherlands) in a joint contract with KfK (FRG) and NRPB (UK). In the first phase a demonstration system will be built, called RADE-AID/D. RADE-AID/D will be used as a decision support system in the intermediate and late phase after a radiological accident. RADE-AID/D will consider countermeasures with respect to external exposure and internal exposure by food ingestion. Countermeasures are evaluated considering reduction in doses and in numbers of health effects, costs, and social effects. The paper covers the structure of the program, presentation of data and results, and the decision analysis technique that is being used. This decision analysis part is an important feature of the system; an advanced decision analysis technique is used, that is able to compare data of varying nature. Furthermore the place of RADE-AID in the decision-making process will be treated. RADE-AID/D is an interactive computer program, that offers the user the possibility to enter relevant data and to have data and results displayed in a variety of ways. Furthermore the system contains an advanced decision analysis technique, that is able to compare data of varying nature. Input data for the decision analysis calculations are provided by models from UFOMOD and MARC-codes

  11. A mixed model study evaluating lean in the transformation of an Orthopaedic Radiology service

    International Nuclear Information System (INIS)

    Martin, Amanda Jane; Hogg, Peter; Mackay, Stuart

    2013-01-01

    Objective: The purpose of the study was to explore the proposition that lean is an effective methodology for service improvement within healthcare by using it to evaluate and implement change in a poor service. Design: A mixed model approach was used with data being collected before and after change. Setting: The orthopaedic radiology out-patient pathway in a large district general hospital was receiving increasing numbers of complaints with long waiting times and poor levels of satisfaction amongst patients and staff. Participants: Data were collected in the form of qualitative and quantitative data taken from questionnaires completed by staff and patients, and quantitative data extracted from the Radiology Information System. A proportionate stratified random sampling method was used to collect data from the patients and a theoretical sample was used for the staff. Intervention: The pre-implementation data was collected during a lean event in which a value stream map of the pathway was created. From this information, changes were planned and implemented, before collecting the post-implementation data using the same methods. Main outcome measures: The aims of the study were to compare pre-implementation and post-implementation data related to patient journey time, patient experience and staff and patient satisfaction. The quantitative data were analysed using Levene's test for equality of variance and a 2-sample t-test to test for comparison of the means. Descriptive statistics were used to analyse data collected from the polar and the selected response questions from the questionnaires, whilst thematic analysis was used to analyse the qualitative data. Results: Results demonstrated that the new service offered a better quality of patient experience with higher levels of staff satisfaction whilst enabling an improvement in productivity. Conclusions: The author proposes that these findings support the proposition that lean is an effective methodology for service

  12. Data processing for the evaluation of the thickness of protective barriers : Case of radiology rooms and external beam radiotherapy

    International Nuclear Information System (INIS)

    RANDRIANANTOANDRO, R.G.G.

    2004-01-01

    The regulation requires that the legal persons who have an intention to use radiation sources shall submit a notification to the Regulatory Authority of such an intention, which shall take the form of a licence or an authorization. The documents of radiological safety including design, construction, clinical utilisation...are attached to this notification. This work intends to assess the thickness of protection barrier and to suggest a facility design in radiology and in radiotherapy which comply with the safety standards. Because the steps of the thickness evaluation require a lot of calculation and abacs, the computer is used for this processing with Visual Basic. [fr

  13. The hormonal and radiological evaluation of adrenal glands, and the determination of the usefulness of low dose ACTH test in patients with renal amyloidosis.

    Science.gov (United States)

    Gündüz, Z; Keleştimur, F; Durak, A C; Utaş, C; Büyükberber, M; Düşünsel, R; Kurtoğlu, S; Poyrazoglu, M H

    2001-03-01

    Amyloidosis is a multisystem disease which may cause organ loss. Renal involvement is the most common clinical problem in amyloidosis, however involvement of endocrin organs is possible. In this study to assess adrenocortical function and to evaluate the usefulness of low dose ACTH test in patients with renal amyloidosis, we determined cortisol, 17-hydroxyprogesteron (17-OHP) and 11-deoxycortisol (11-DOC) responses to both 1 microg and 250 microg Synacthen. We also determined the size of adrenal glands radiologically by using computerized tomography. Twenty one patients with renal amyloidosis and 16 healthy subjects for hormonal evaluation, and 20 patients with renal amyloidosis and 22 healthy subjects for radiologic evaluation were included in the study. In four patients (19%) peak serum cortisol levels following stimulation with the low dose of Synacthen were less than 20 microg/dL (550 nmol/L). Two of them had also subnormal cortisol response to the 250 microg Synacthen stimulation test. Basal and stimulated levels of 11-DOC were lower than those of control values (p=0.000 and p<0.01 respectively). The mean 11-DOC responses to stimulation with 1 microg Synacthen were also significantly lower than the values obtained after the simulation with 250 microg Synacthen (p<0.01 and p=0.000). Cortisol responses to the stimulation with 250 microg Synacthen were also lower than the control responses (p<0.05). 17-OHP responses were similar to the control values in both tests. In the radiological evaluation the mean maximum width of right adrenal glands and the mean anterior and maximum width of left adrenal glands were significantly greater in the patient group (p<0.01). In conclusion, adrenal involvement and adrenal insufficiency is common in amyloidosis. Low 11-DOC levels in amyloidosis is a new finding and further detailed studies is required to explain its cause.

  14. Indigenous development and performance evaluation of BARC aerodynamic size separator (BASS)

    International Nuclear Information System (INIS)

    Singh, Sanjay; Purwar, R.C.; Das, Tanmoy; Narayanan, K.P.; Sapra, B.K.; Sunny, Faby; Khan, Arshad; Mayya, Y.S.

    2002-06-01

    Commercially available cascade impactors, commonly used for aerodynamic size separation of aerosol particles, are based on the principle of inertial impaction. As of now, these instruments are imported at a cost of several lakhs of rupees; hence an effort has been made to develop an aerodynamic particle sizer indigenously in BARC. This unit, referred to as BARC Aerodynamic Size Separator (BASS), separates aerosols into seven size classes ranging from 0.53 μm to 10 μm and operates at a flow rate of 45 Ipm. Intercomparison studies between the standard Andersen Mark-II (Grasbey Andersen Inc.) impactor and BASS using nebulizer generated aerosols have consistently shown excellent performance by BASS in all respects. In particular, BASS yielded the parameters of polydisperse aerosols quite accurately. Experiments to evaluate the individual stage cut-off diameters show that these are within 8% of their designed value for all stages except the higher two stages which indicate about 30% lower values than the designed ones. The replotting of all the mass distribution data using the experimental cut-off diameters showed perfect lognormal fits, thereby indicating that these diameters are closer to the true stage cut-off diameters for BASS. The studies show that BASS will be suitable for determining the particle size distributions in the context of the radiological safety programmes of DAE. Being indigenous in design, it may be fabricated on a commercial scale at a cost far less than that of the imported units. Such a venture will greatly help several national programmes on atmospheric pollution being carried out by many laboratories and institutions across the country. (author)

  15. Evaluating the impact of a Canadian national anatomy and radiology contouring boot camp for radiation oncology residents.

    Science.gov (United States)

    Jaswal, Jasbir; D'Souza, Leah; Johnson, Marjorie; Tay, KengYeow; Fung, Kevin; Nichols, Anthony; Landis, Mark; Leung, Eric; Kassam, Zahra; Willmore, Katherine; D'Souza, David; Sexton, Tracy; Palma, David A

    2015-03-15

    Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course ("boot camp") designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, Pradiology in addition to enhancing their confidence and accuracy in contouring. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Radiological Assessment of Bioengineered Bone in a Muscle Flap for the Reconstruction of Critical-Size Mandibular Defect

    Science.gov (United States)

    Al-Fotawei, Randa; Ayoub, Ashraf F.; Heath, Neil; Naudi, Kurt B.; Tanner, K. Elizabeth; Dalby, Matthew J.; McMahon, Jeremy

    2014-01-01

    This study presents a comprehensive radiographic evaluation of bone regeneration within a pedicled muscle flap for the reconstruction of critical size mandibular defect. The surgical defect (20 mm×15 mm) was created in the mandible of ten experimental rabbits. The masseter muscle was adapted to fill the surgical defect, a combination of calcium sulphate/hydroxyapatite cement (CERAMENT™ |SPINE SUPPORT), BMP-7 and rabbit mesenchymal stromal cells (rMSCs) was injected inside the muscle tissue. Radiographic assessment was carried out on the day of surgery and at 4, 8, and 12 weeks postoperatively. At 12 weeks, the animals were sacrificed and cone beam computerized tomography (CBCT) scanning and micro-computed tomography (µ-CT) were carried out. Clinically, a clear layer of bone tissue was identified closely adherent to the border of the surgical defect. Sporadic radio-opaque areas within the surgical defect were detected radiographically. In comparison with the opposite non operated control side, the estimated quantitative scoring of the radio-opacity was 46.6% ±15, the mean volume of the radio-opaque areas was 63.4% ±20. Areas of a bone density higher than that of the mandibular bone (+35% ±25%) were detected at the borders of the surgical defect. The micro-CT analysis revealed thinner trabeculae of the regenerated bone with a more condensed trabecular pattern than the surrounding native bone. These findings suggest a rapid deposition rate of the mineralised tissue and an active remodelling process of the newly regenerated bone within the muscle flap. The novel surgical model of this study has potential clinical application; the assessment of bone regeneration using the presented radiolographic protocol is descriptive and comprehensive. The findings of this research confirm the remarkable potential of local muscle flaps as local bioreactors to induce bone formation for reconstruction of maxillofacial bony defects. PMID:25226170

  17. Radiological assessment of bioengineered bone in a muscle flap for the reconstruction of critical-size mandibular defect.

    Directory of Open Access Journals (Sweden)

    Randa Al-Fotawei

    Full Text Available This study presents a comprehensive radiographic evaluation of bone regeneration within a pedicled muscle flap for the reconstruction of critical size mandibular defect. The surgical defect (20 mm × 15 mm was created in the mandible of ten experimental rabbits. The masseter muscle was adapted to fill the surgical defect, a combination of calcium sulphate/hydroxyapatite cement (CERAMENT™ |SPINE SUPPORT, BMP-7 and rabbit mesenchymal stromal cells (rMSCs was injected inside the muscle tissue. Radiographic assessment was carried out on the day of surgery and at 4, 8, and 12 weeks postoperatively. At 12 weeks, the animals were sacrificed and cone beam computerized tomography (CBCT scanning and micro-computed tomography (µ-CT were carried out. Clinically, a clear layer of bone tissue was identified closely adherent to the border of the surgical defect. Sporadic radio-opaque areas within the surgical defect were detected radiographically. In comparison with the opposite non operated control side, the estimated quantitative scoring of the radio-opacity was 46.6% ± 15, the mean volume of the radio-opaque areas was 63.4% ± 20. Areas of a bone density higher than that of the mandibular bone (+35% ± 25% were detected at the borders of the surgical defect. The micro-CT analysis revealed thinner trabeculae of the regenerated bone with a more condensed trabecular pattern than the surrounding native bone. These findings suggest a rapid deposition rate of the mineralised tissue and an active remodelling process of the newly regenerated bone within the muscle flap. The novel surgical model of this study has potential clinical application; the assessment of bone regeneration using the presented radiolographic protocol is descriptive and comprehensive. The findings of this research confirm the remarkable potential of local muscle flaps as local bioreactors to induce bone formation for reconstruction of maxillofacial bony defects.

  18. Evaluation of radiological impacts for environmental radioactivity distribution in the Kartini reactor area

    International Nuclear Information System (INIS)

    Yazid, M.; Suratman; Sutresna, G.; Aminjoyo, S.

    1996-01-01

    This evaluation covered of gross radioactivity. K-40 radioactivity in the water, soil and grass samples. The measurement of Cs-137 and Sr-90 radioactivity in the water samples have also been done. The aim of this research was determined of radiological impacts in the environment around the Kartini reactor. The water, soil and plant samples were counted of gross beta, Sr-90 activity by beta counter and for K-40, Cs-137 activity by low background gamma spectrometer. For this evaluation can be concluded there are no indication of the radioactivity release from the Kartini reactor operation. Gross beta radioactivity in the water, soil and grass sample are between 0.06-0.61 Bq/l, 0.24-0.79 Bq/g and 3.47-5.70 Bq/g ash. Radioactivity of K-40 in the water, soil and grass sample are between 0.09-0.56 Bq/l, 0.12-0.59 Bq/g and 0.29-0.93 Bq/g ash. The radioactivity of Cs-137 in the water samples are between under limit detectable level to 88.62 mBq/l and Sr-90 are between under limit detectable level to 24.22 mBq/l. (author)

  19. Production and consumption of foods in Spain, for its applications in radiological impact evaluations

    International Nuclear Information System (INIS)

    Robles, B.; Suanez, A.; Vazquez, C.

    1994-01-01

    This work is focussed on characterization, organization and analysis for the most relevant regional parameters used in dose assessment models when a food pathway contamination occurs. It was carried in the framework of a contract with a several European Institutions (CEA-IPSN, NRPB) for the development of a general methodology for the evaluation of the radiological consequences caused by accidentally radioactive releases into the environment. Spain, a member of the mediterranean country group, has a remarkably diverse climate which determines crop production agricultural practices, and consequently the animal and human diets. This project intention in to study in depth these particular characteristics and their consequences so that the estimated dose received by an individual reflects a variety of factors, therefore, the production and consumption of the five autonomous Mediterranean regions have been compared individually and globally with the national production and consumption averages. These data have been used in committed dose evaluation exercise applied to the ingestion of contaminated food throughout the first year after an accidental release of Caesium-137. This exercise was realized within the TARRAS (Transfer of Accidentally Released of Radionuclides in Agricultural Systems) project, financed by CE, ENRESA and CSN. (Author) 6 ref

  20. Evaluation of doses in conventional radiology in the cities of Rio de Janeiro e Recife, Brazil

    International Nuclear Information System (INIS)

    Azevedo, Ana Cecilia P.; Osibote, Adelaja O.; Khoury, Helen J.

    2005-01-01

    This work is part of a program of evaluating doses in patients developed in several hospitals in the States of Rio de Janeiro and Pernambuco. We used the program DoseCal to evaluate the Input Skin Dose (DEP) and the Effective Dose (DE) in big public hospitals in the cities of Rio de Janeiro and Recife. It were included in the survey the doses of chest radiographs, cervical spine, lumbar spine, skull and pelvis in the projections AP, PA and LAT. To chest in PA the average value of DEP for the hospital A was 0.19 mGy. For to hospital B was 0.07 mGy. For the exam of the skull in PA the average value in A was 3.25 mGy and B of 0.49 mGy. With respect to radiological techniques might be noted that in most cases the hospital A used kilovoltage lower than in B and miliamperes higher. This can be one of the explanations for the difference of the values found for DEP and DE. The results showed significant discrepancies in values of doses as radiographic techniques when compared to the requirements established by the European Community for X-rays with image quality. This result is due to several factors: filtration, radiographic technique, professional technical experience and performance of radiographic equipment

  1. Radiology on Internet: advice in consulting websites and evaluating their quality

    International Nuclear Information System (INIS)

    Rolland, Y.; Bousquet, C.; Duvauferrier, R.; Pouliquen, B.; Le Beux, P.; Fresnel, A.

    2000-01-01

    Services offered by Internet are increasing continually and 15,000 medical websites covering all the specialties are available presently. Finding relevant information with a spider-web organization is difficult. We recommend starting with hierarchical lists which propose a selection of sites corresponding to medical specialties. We give our selection of important radiological websites dealing with image databases, case reports, radioanatomy and continuing medical education. While surfing the Web, an evaluation of the quality of websites is necessary. We used quality criteria proposed by Darmoni to rate the quality of ten websites. The global quality is good; help pages and external links are the main noticed shortcomings. All webmasters should pay attention to quality criteria and show visible marks of Darmoni criteria on their home page. To be able to foresee which Internet options should be developed, we evaluated our website and sent a questionnaire to our users. Clinical cases are the most requested facilities; they could be used for continuing medical education. (orig.)

  2. Indicative to evaluate the efficiency of a program of radiological protection

    International Nuclear Information System (INIS)

    Lescano, R.; Caspani, C.

    1998-01-01

    The purpose of the present work is to find an indicator that permit to evaluate objectively, that is to say through a number, the efficient accomplishment of radiological protection actions that is reflected in an improvement of the safety conditions with which is developed labor. The employed method consists of average evaluation of the individual doses received by the workers pursuing their occupations, measure in a great population, contrasted with the average of environmental dose of located monitors always in the same place. It can be employed film dosimeters, TLD, direct-reading pocket dosimeters with exposure monitor or any combination between them, provided that in the course of the time are compared always the same. Applying this method between the year 1991 to 1997, in part of Santa Fe province (Argentine), is observed that the individual dose average of the workers varies randomly and also rises and decrease unco-ordinately the environmental dose, but relating booth is arrived to a numerical value that has a comparable behavior to the objectively observed. (author)

  3. Evaluation of the efficiency of different methods of personal dosimetry in vascular interventional radiology

    International Nuclear Information System (INIS)

    Bacchim Neto, F.A.; Alves, A.F.F.; Rosa, M.E.D.; Pina, D.R.

    2017-01-01

    Interventional Radiology - IR is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. The objective of the study is to perform a complete evaluation of occupational exposures and to determine the efficiency of different personal dosimetry methods used in IR. We evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. And, based on this analysis, determine the characteristics of each methodology. One of the methods of personal dosimetry recommended by Brazilian legislation was the most conservative, overestimating, on average, the effective dose of professionals by up to 200%, reaching maximum values close to 400%. The most accurate method was that used in North America. This method did not overestimate the effective dose of the professionals more than a few percent and their standard deviation relative to the effective reference dose were the lowest. Based on these results, the choice of methodologies employing at least two dosimeters, one under and above protective aprons is recommended. In addition, in some situations where the dose in the hands may be high, additional dosimeters for this region are also recommended

  4. Evaluation of quality control in the college of medical radiological sciences, conventional x-ray department

    International Nuclear Information System (INIS)

    Babiker, Esameldeen Mohamed Tom

    2002-02-01

    Quality control in diagnostic radiography aims to ensure continuous production of diagnostic images with optimum quality, using minimum necessary dose to the patients and staff. Therefore an ineffective quality control program can lead to poor quality images that can impair diagnosis, increase operating costs and contribute to unnecessary radiation exposure to both patients and staff. Apply basic quality control program is responsibility of each x-ray facility, and to achieve maximum benefits, all levels of management and technical staff must support and participate in operating the programme. The main parameters to be monitored during the quality control programme include: dose consistency, k Vp accuracy, k Vp variations, exposure timer accuracy, besides checking image receptors, recording system and processing conditions. The aims of this project is to evaluate the quality control in the x-ray department of the college of medical radiologic sciences. The evaluation was an experimental study done by checking the operational status of the radiographic equipment, beside data collection using questionnaires regarding quality control. In the applied experiments the results show that there is a noted variation in the accuracy of k Vp, exposure timer and also in the dose consistency. The obtained results from image receptors and processing system showed noted variations too. The results of the questionnaire and direct interviewing showed other causes of quality degradation such as absence of test tools, the status of the equipment, absence of regular quality control testing, in addition to absence of an organized team to deal with quality. (Author)

  5. Feasibility study to combine the evaluation of radiological and chemical-toxicological effects of old contaminated sites

    International Nuclear Information System (INIS)

    Jacob, P.; Proehl, G.

    1997-01-01

    The uranium mining regions of the German Federal States Saxony, Thuringia and Saxony-Anhalt are contaminated by radionuclides and by chemical substances. For both, ionizing radiations and chemicals, concepts and models exists to assess possible health effects for the population living in such areas. However, these assessment models were developed independently for both kinds of contaminants. Therefore, the 9 th Conference of the State Ministers for Environmental Protection have claimed that for the evaluation of contaminated sites the radiological and chemical contaminants should be integrated into a joint assessment. This feasibility study describes the state of the art of the concepts and models used for the evaluation of radiological and chemical contaminants. The similarities and differences of these evaluation methods are identified and discussed. Suggestions are made for an integrated assessment to standardize the evaluation of sites contaminated by radionuclides or chemicals. (orig.) [de

  6. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  7. Evaluation of awareness on radiation protection and knowledge about radiological examinations in healthcare professionals who use ionized radiation at work.

    Science.gov (United States)

    Yurt, Ayşegül; Cavuşoğlu, Berrin; Günay, Türkan

    2014-06-01

    In this study, we evaluated the knowledge and perception and mitigation of hazards involved in radiological examinations, focusing on healthcare personnel who are not in radiation-related occupations, but who use ionising radiation as a part of their work. A questionnaire was applied to physicians, nurses, technicians and other staff working in different clinics that use radiation in their work, in order to evaluate their knowledge levels about ionizing radiation and their awareness about radiation doses resulting from radiological examinations. The statistical comparisons between the groups were analyzed with the Kruskal Wallis test using the SPSS program. Ninety two participants took part in the study. Their level of knowledge about ionizing radiation and doses in radiological examinations were found to be very weak. The number of correct answers of physicians, nurses, medical technicians and other personnel groups were 15.7±3.7, 13.0±4.0, 10.1±2.9 and 11.8±4.0, respectively. In the statistical comparison between the groups, the level of knowledge of physicians was found to be significantly higher than the level of the other groups (p=0.005). The present study demonstrated that general knowledge in relation to radiation, radiation protection, health risks and doses used for radiological applications are insufficient among health professions using with ionizing radiation in their work.

  8. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study.

    Science.gov (United States)

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. "Management and empowerment of human resources'' (weight = 0.465) and "requirements and facilities" (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country's hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step towards

  9. Application of Analytical Hierarchy Process Approach for Service Quality Evaluation in Radiology Departments: A Cross-Sectional Study

    International Nuclear Information System (INIS)

    Alimohammadzadeh, Khalil; Bahadori, Mohammadkarim; Hassani, Fariba

    2016-01-01

    Radiology department as a service provider organization requires realization of quality concept concerning service provisioning knowledge, satisfaction and all issues relating to the customer as well as quality assurance and improvement issues. At present, radiology departments in hospitals are regarded as income generating units and they should continuously seek performance improvement so that they can survive in the changing and competitive environment of the health care sector. The aim of this study was to propose a method for ranking of radiology departments in selected hospitals of Tehran city using analytical hierarchical process (AHP) and quality evaluation of their service in 2015. This study was an applied and cross-sectional study, carried out in radiology departments of 6 Tehran educational hospitals in 2015. The hospitals were selected using non-probability and purposeful method. Data gathering was performed using customized joint commission international (JCI) standards. Expert Choice 10.0 software was used for data analysis. AHP method was used for prioritization. “Management and empowerment of human resources’’ (weight = 0.465) and “requirements and facilities” (weight = 0.139) were of highest and lowest significance respectively in the overall ranking of the hospitals. MS (weight = 0.316), MD (weight = 0.259), AT (weight = 0.14), TS (weight = 0.108), MO (weight = 0.095), and LH (0.082) achieved the first to sixth rankings respectively. The use of AHP method can be promising for fostering the evaluation method and subsequently promotion of the efficiency and effectiveness of the radiology departments. The present model can fill in the gap in the accreditation system of the country’s hospitals in respect with ranking and comparing them considering the significance and value of each individual criteria and standard. Accordingly, it can predict an integration of qualitative and quantitative criteria involved and thereby take a decisive step

  10. Evaluation of the technical condition of medium-sized boilers

    Directory of Open Access Journals (Sweden)

    Lošák Pavel

    2018-01-01

    Full Text Available The recent trend in the steam and electricity production has been both to increase the efficiency of the facility and to keep tightening legislation concerning emission limits. The lifetime of energy equipment is greatly influenced by the operating temperature, pressure and operating characteristics. The new conditions lead the operator to more often changes of these parameters, which has negative influence to the facility in terms of service life. Precise knowledge of the facility being operated and the ability to predict the residual life of its key parts in time is therefore necessary. A new methodology for determining the residual life and evaluating problematic situations of medium size boilers was developed at Brno University of Technology. Its approaches and advantages will be presented in this paper. The methodology provides the user with approaches for the lifetime evaluation of an equipment as a whole, based on detailed knowledge of the equipment being investigated and the ongoing damage. Additionally, if the equipment is continuously evaluated, it is possible to extend the inspection interval or to achieve a significantly higher lifetime of the entire equipment, thereby reducing the economic cost. If defined criteria are met, the methodology also allows inclusion of FEM and CFD simulations for achieving higher relevance of the results.

  11. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  12. Microbiological contamination in digital radiography: evaluation at the radiology clinic of an educational institution.

    Science.gov (United States)

    Malta, Cristiana P; Damasceno, Naiana Nl; Ribeiro, Rosangela A; Silva, Carolina Sf; Devito, Karina L

    2016-12-01

    The aim of this study was to evaluate the contamination rate of intra and extraoral digital X ray equipment in a dental radiology clinic at a public educational institution. Samples were collected on three different days, at two times in the day: in the morning, before attending patients, and at the end of the day, after appointment hours and before cleaning and disinfection procedures. Samples were collected from the periapical X-ray machine (tube head, positioning device, control panel and activator button), the panoramic X- ray machine (temporal support, bite block, control panel and activator button), the intraoral digital system (sensor), and the digital system computers (keyboard and mouse). The samples were seeded in different culture media, incubated, and colony forming units (CFU/mL) counted. Biochemical tests were performed for suspected colonies of Staphylococcus, Streptococcus and Gramnegative bacilli (GNB). Fungi were visually differentiated into filamentous fungi and yeasts. The results indicated the growth of fungi and Staphylococcus fromall sampling locations. GNB growth was observed from all sites sampled from the intraoral X-ray equipment. On the panoramic unit, GNB growth was observed in samples from activator button, keyboard and mouse. In general, a higher number of CFU/mL was present before use. It can be concluded that more stringent protocols are needed to control infection and prevent X-ray exams from acting as vehicle for cross contamination. Sociedad Argentina de Investigación Odontológica.

  13. Malpractice suits in chest radiology: an evaluation of the histories of 8265 radiologists.

    Science.gov (United States)

    Baker, Stephen R; Patel, Ronak H; Yang, Lily; Lelkes, Valdis M; Castro, Alejandro

    2013-11-01

    The aim of this study was to present rates of claims, causes of error, percentage of cases resulting in a judgment, and average payments made by radiologists in chest-related malpractice cases in a survey of 8265 radiologists. The malpractice histories of 8265 radiologists were evaluated from the credentialing files of One-Call Medical Inc., a preferred provider organization for computed tomography/magnetic resonance imaging in workers' compensation cases. Of the 8265 radiologists, 2680 (32.4%) had at least 1 malpractice suit. Of those who were sued, the rate of claims was 55.1 per 1000 person years. The rate of thorax-related suits was 6.6 claims per 1000 radiology practice years (95% confidence interval, 6.0-7.2). There were 496 suits encompassing 48 different causes. Errors in diagnosis comprised 78.0% of the causes. Failure to diagnose lung cancer was by far the most frequent diagnostic error, representing 211 cases or 42.5%. Of the 496 cases, an outcome was known in 417. Sixty-one percent of these were settled in favor of the plaintiff, with a mean payment of $277,230 (95% confidence interval, 226,967-338,614). Errors in diagnosis, and among them failure to diagnose lung cancer, were by far the most common reasons for initiating a malpractice suit against radiologists related to the thorax and its contents.

  14. Radiological evaluation of the cranio vertebral junction; Avaliacao radiologica da transicao cranio-vertebral

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Silvia Marcal Benicio de; Haetinger, Rainer Guilherme [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Cabeca e Pescoco]. E-mail: sbm@uol.com.br; Schettini, Marianna Cunha; Lima, Sergio Santos [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil); Mourao, Maria Lucia; Mendonca, Renato Adam [Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP (Brazil). Setor de Neuroradiologia

    2005-04-15

    The cranio vertebral junction (CVJ) comprises the occiput, atlas, their joints and ligaments. Besides conventional x-rays other imaging methods are need for the assessment of CVJ including high resolution computerized tomography (CT) and magnetic resonance imaging (MRI) which provide specific parameters such as field of view, slice thickness and incremental movement of the patient. A dynamic study is also important to assess the stability of the cranio vertebral junction and the effect upon the bulbomedullary junction. The aim of this study is to review the techniques used in the evaluation of the CVJ, the semiological parameters, and the most frequent disorders affecting this region. We review the literature and present conventional x-ray, CT and MRI images from the didactic file of the Radiology service 'Med Imagem - Beneficiencia Portuguesa de Sao Paulo, SP, Brazil, of cases with normal anatomy and the main congenital and acquired disorders of the CVJ. In daily practice, CVJ disorders are diagnoses using CT and MRI scans of the head and cervical spine. It is essential to be familiar with these conditions in order to preform specific tests which will allow a detailed study of the CVJ, thus providing the basis for the treatment, whenever indicated. (author)

  15. Preliminary Evaluation of a Radiological Biomarker to Characterize the Longitudinal Evolution of Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Muñoz-Hernando, M.; Macias, P.; Abella, M.; Desco, M.; Sharpe, S.; Vaquero, J.J.; Muñoz-Barrutia, M.

    2016-07-01

    Tuberculosis (TB) remains the world's second-deadliest disease, due to a single infectious agent. The population that has developed multidrug resistance is increasingly important boosting the interest to run assays of novel multi-antibiotic combinations. Drug assays of new chemotherapies for treating TB require following subjects to assess response at several time points. Radiological examination of the subjects is a promising technique for that task. In this context, the main objective of the present work is twofold: 1) To evaluate the performance of a tool, dedicated to the automatic segmentation of TB infected lungs in chest Computed Tomography (CT) scans; 2) To present a method to automatically compute an imaging biomarker capable to characterize the disease longitudinal evolution. The selected biomarker is based on the intensity differences between the healthy and sick lung parenchyma in chest CT scans. Our results demonstrated a good similarity between the automatically segmented lungs and those delineated using a semi-automatic tool that relays on manual corrections. Furthermore, regarding the automatic extraction of the imaging biomarker, results showed a good inter-method agreement and concordance with respect to those obtained using a visually defined set of thresholds. (Author)

  16. A comparison of bone scanning and radiology in the evaluation of patients with metabolic bone disease

    International Nuclear Information System (INIS)

    Fogelman, I.; Carr, D.

    1980-01-01

    Bone scan and radiographs were evaluated in 80 patients with metabolic bone disease (27 with osteoporosis, 14 with primary hyperparathyroidism, 24 with renal osteodystrophy and 15 with osteomalacia). The bone scan did not suggest a metabolic bone disorder in any of 27 patients with histologically proven osteoporosis. In 22 (81%) patients radiographs were reported as showing osteoporosis. In 19 (70%) vertebral fractures were seen on X-ray while these were noted in 11 (41%) patients on the bone scan. Vertebral fractures were usually visualised on the bone scan when these had occurred less than one year previously. In primary hyperparathyroidism the bone scan was suggestive of a metabolic bone disorder in 7 of 14 (50%) patients, while radiographs were reported as showing evidence of hyperparathyrodism in three (21%) cases. The bone scan suggested the presence of a metabolic bone disorder in all 24 patients with renal osteodystrophy and 15 patients with osteomalacia while the correct diagnosis was obtained in 14 (58%) and nine (60%) of these patients on X-ray. It is concluded that the bone scan is the more sensitive investigation in patients with osteomalacia, primary hyperparathyroidism and renal osteodystrophy. For osteoporosis radiology is the investigation of choice but the bone scan may be of value in assessing the duration of vertebral collapse. (author)

  17. Evaluation of radiological safety conditions of panoramic portable irradiators of industrial radiography used in Brazil

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2003-08-01

    In Brazil, the applications of ionizing radiation in industrial area are performed in about 900 installations, in which around 3000 radioactive sources are handled. Industrial radiography represents 14 % of this total, with 217 X rays equipment and 287 gamma radiography apparatus, according to a survey conducted in the present work. From these gamma apparatus, 90 % employ 192 Ir sources, followed by 60 Co and 75 Se, with 5 % each. The great majority of the 192 Ir apparatus have been in continuous usage in Brazil for more than 20 years, which means that they are old equipment. The totality of the 11 models of 192 Ir apparatus used in Brazil is imported from abroad. Those apparatus are portable, and almost all operate according to category II, i.e., the source assembly is mechanically projected out of the container. This last characteristic, besides the fact that the apparatus are already old-fashioned and worn-out, raises concerns about their radiological safety. The main objective of this work was to develop a specific methodology for inspection, testing and assessment of the radiological safety devices and state of maintenance of the 192 Ir apparatus. The idea is to prevent accidents, as physical failures can lead to overexposure of working staffs. In order to accomplish this, almost a hundred 192 Ir apparatus, from the 11 models used in Brazil, were studied. According to our results, almost 20 % of the 97 apparatus evaluated presented some kind of unsafe condition for proper operation, like poor state of maintenance and faults at the lock that retains the source at the secure position. From the 11 imported models of 192 Ir apparatus in use in Brazil, six models were already manufactured incorporating the safety devices specified by the first edition of the Standard ISO 3999, edited in 1977. However, five models do not comply even with this first edition of the Standard ISO 3999. Thus, they lack some important and basic safety devices. None of the 11 models comply

  18. Assessing Expertise in Radiology : Evaluating and Improving the Assessment of Knowledge and Image Interpretation Skill

    NARCIS (Netherlands)

    Ravesloot, C.J.

    2016-01-01

    Aim: Expert radiologists are excellent image interpreters. Unfortunately, image interpretation errors are frequent even among experienced radiologists and not much is known about which factors lead to expertise. Increasing assessment quality can improve radiological performance. Progress tests can

  19. Evaluation of Stress and a Stress-Reduction Program Among Radiologic Technologists.

    Science.gov (United States)

    Reingold, Lynn

    2015-01-01

    To investigate stress levels and causes of stress among radiologic technologists and determine whether an intervention could reduce stress in a selected radiologic technologist population. Demographic characteristics and data on preintervention stress sources and levels were collected through Internet-based questionnaires. A 6-week, self-administered, mindfulness-based stress-reduction program was conducted as a pilot intervention with 42 radiologic technologists from the Veterans Administration Medical Center. Data also were collected postintervention. Identified sources of stress were compared with findings from previous studies. Some radiologic technologists experienced improvement in their perceptions of stress after the intervention. Sources of stress for radiologic technologists were similar to those shown in earlier research, including inconsistent management, poor management communication, conflicting demands, long work hours, excessive workloads, lack of work breaks, and time pressures. The mindfulness-based stress-reduction program is an example of an inexpensive method that could improve personal well-being, reduce work errors, improve relationships in the workplace, and increase job satisfaction. More research is needed to determine the best type of intervention for stress reduction in a larger radiologic technologist population.

  20. OECD/NEA Radiological characterisation in decommissioning - Evaluation of questionnaire. Strategies for Radiological Characterisation used by Decommissioning Projects in OECD Countries

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan; Haneke, K.

    2012-01-01

    In the first half of 2011, the Radiological Characterization and Decommissioning Task Group (RCD) of the WPDD of the OECD/NEA has prepared a questionnaire on the characterisation of nuclear facilities that has been circulated among nuclear installations in various OECD countries. The aim of this questionnaire was to gather information on the approaches and methods that are used for radiological characterisation (RC) for systems and components, for buildings and for sites (land), on domestic and international guidance and regulations that govern RC, and on the experience with RC that is already available in the particular country. The number of responses to this questionnaire that were received in the second half of 2011 was very satisfactory, so that a broad overview is now available from the following countries: Belgium, Canada, Denmark, Finland, France, Germany, Japan, Korea, Spain, Sweden, and United Kingdom. The presentation deals with the results that were obtained from the evaluation of these questionnaires and gives overviews of the objectives of characterisation, the input data for planning of characterisation, the measurement techniques that were used for metallic structures and components, for buildings and for sites, the data management and QA measures, the obstacles that were encountered, the experience with availability of as-built plans, the regulatory framework and guidelines, and the costs for RC. All information on RC is further broken down with respect to the operational phase (where RC is used for preliminary decommissioning planning), the transition phase (where RC supports decommissioning planning) and the actual decommissioning phase (where RC is needed for dismantling, decontamination and treatment of systems, components, buildings etc.). The presentation also offers conclusions on these subjects. (authors)

  1. Development of nano-sized α-Al2O3:C films for application in digital radiology

    International Nuclear Information System (INIS)

    Silva, Edna C.

    2011-01-01

    Ceramic materials are widely used as sensors for ionizing radiation. In nuclear applications, the alpha-alumina doped with carbon (α-Al 2 O 3 :C) is the most widely ceramic used because of its excellent optically stimulated luminescence (OSL) and thermoluminescent (TL) properties applied to detection of ionizing radiation. Another application of OSL and TL materials are in Digital Radiography, with ceramic/polymeric film composites. Recently, Computed Radiography (CR) devices based on OSL materials are replacing the old conventional film radiography. In this study we investigate the thermoluminescence of nano-sized α-Al 2 O 3 samples doped with different percentages of carbon, sintered in reducing atmospheres at temperatures ranging from 1300 to 1750 deg C. The results indicate that the nano-sized α-Al 2 O 3 :C materials have a luminescent response that could be due to both OSL and RPL properties, but without application to radiation dosimetry. Moreover, the results indicate that micro-sized α-Al 2 O 3 :C, doped with 0.5% carbon, and nano-sized ones doped with 2% of carbon, present thermoluminescent signal around 30 to 100 times the TL output signal of commercial TLD-100, the most used TL dosimeter in the world. The results indicate that these ceramic nano-particles have great potential for use in Digital Radiography based on thermoluminescent film imaging, being able to provide image resolutions much higher than the micro-sized α-Al 2 O 3 :C, in view of their improved resolution provided by nano-particulates. (author)

  2. A CLINICAL STUDY ON SURGICAL MANAGEMENT OF TIBIAL PLATEAU FRACTURES - FUNCTIONAL AND RADIOLOGICAL EVALUATION

    Directory of Open Access Journals (Sweden)

    Bhavani

    2015-10-01

    Full Text Available BACKGROUND: Tremendous advance in mechanization and fastness of travel have been accompanied by steep increase in number and severity of fractures and those of tibial plateau are no exception. Knee being one of the major weight bearing joints of the body, fractures around it will be of paramount importance. AIM OF STUDY: This study is to analyze the functional outcome of CRIF or ORIF with or without bone grafting in tibial plateau fractures in adults. MATERIALS AND METHODS: 30 cases of tibial plateau fractures treated by various modalities were studied from 1 - 8 - 2012 to 31 - 1 - 2014 at our institution and followed for a minimum of 6 months. Fractures were evaluated using Modified Rasmussen’s Clinical, Radiological grading system. RESULTS : The selected patients were evaluated thoroughly and after the relevant investigations, were taken for surgery. The fractures were classified as per the SCHATZKER’S types and operated accordingly with CRIF with Percutaneous cannulated cancellous screws, ORIF with buttress plate/LCP with or without bone grafting. Immobilization of fractures continued for 3 weeks by POP slab. Early range of motion was then started. Weight bearing up to 6 - 8 weeks was not allowed. The full weight bearing deferred until 12 weeks or complete fracture union . The knee range of motion was excellent to very good, gait and weight bearing after complete union was satisfactory, knee stiffness in 3 cases , wound dehiscence and infection in 1 case and non - union in none of our cases was noted. CONCLUSION: Functional outcome is better in operatively treated tibial plateau fractures in adults, because it gives excellent anatomical reduction and rigid fixation to restore articular congruity and early motion thereby preventing knee stiffness.

  3. Evaluation of actual vs expected photodynamic therapy spot size.

    Science.gov (United States)

    Ranchod, Tushar M; Brucker, Alexander J; Liu, Chengcheng; Cukras, Catherine A; Hopkins, Tim B; Ying, Gui-Shuang

    2009-05-01

    To determine the accuracy of the photodynamic therapy (PDT) laser spot size on the retina as generated by 2 Food and Drug Administration (FDA)-approved lasers. Prospective observational case series. Fundus photographs were taken of 1 eye of each of 10 subjects with the WinStation 4000 fundus photography system (OIS; Ophthalmic Imaging Systems, Sacramento, California, USA); disc size was calculated using OIS software. Slit-lamp photographs were taken of the PDT laser spot focused on the retina adjacent to the optic disc, using various spot sizes in combination with 3 different contact lenses and 2 different lasers. Spot size at the retina was determined by measuring the ratio of disc diameter to spot diameter in Adobe Photoshop (San Jose, California, USA) and applying this ratio to the OIS disc measurements. Spot size at the retina averaged 87% of expected spot size for the Coherent Opal laser (Coherent Inc, Santa Clara, California, USA) and 104% of expected spot size for the Zeiss Visulas laser (Carl Zeiss Meditec Inc, Dublin, California, USA)(P = .002). Multivariate analysis demonstrated that percentage of expected spot size decreased with larger spot diameter (P = .01 for Coherent laser; P = .02 for Zeiss laser). PDT spot size at the retina appears to be consistently smaller than expected for the Coherent laser while the spot size was consistently within 10% of expected size for the Zeiss laser. The deviation from expected size increased with larger spot size using the Coherent laser.

  4. Operation evaluation of Venezuelan radiological service; Evaluacion del funcionamiento de un servicio de radiologia de un hospital venezolano

    Energy Technology Data Exchange (ETDEWEB)

    Padron, A.; Sanchez, A.; Martinez, V.; D' Alessandro, A.

    2006-07-01

    This work's intention is to evaluate the Radiology Service operation of Venezuelan hospital based on the Venezuelan Norms for the ionizing radiations use in medical diagnostic. The investigation's results show a violation of these norms. Therefore we propose some recommendations (about the personal and area dosimetry, medical equipment maintenance and calibration and the elaboration of procedures manuals) to be considered by the Institution to optimizing the Service's activities. (Author)

  5. Current state of a dosimetric evaluation programme in diagnostic radiology installations in Spain

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Calzado, A.; Delgado, V.; Moran, P.; Sanchez, B.; Murias, F.

    1988-01-01

    The Medical Physics Group at the School of Medicine of the Complutense University of Madrid, started a programme on the study of radiation doses in relation to Diagnostic Radiology in the area of Madrid in 1986, in cooperation with the Department of Health and Consumer Affairs, and several Madrid area hospitals as well as some Outpatient Centers. In Spain, the National Health Service (NHS) (through the National Institute of Health, INSALUD), potentially cares for the health of approximately 94% of the population. This figure reaches 99% at the Community of Madrid. Radiological examinations are performed mainly in Hospitals and Outpatient Centers (the latter making up a first link in the patient's radiological diagnosis). Private Diagnostic Radiology is used by the remaining 6% of the population (not taking into account the population attended in military hospitals), and by patients who in spite of having access to NHS Diagnostic Radiology Services, prefer to choose the private sector for different reasons. Besides the data we obtained during the first year of study from four large Madrid-area hospitals (and a few outpatient centers); we have used data furnished by the Department of Health and Consumer Affairs, the INSALUD and other sources

  6. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  7. Radiological evaluation of pulmonary atresia: An analysis of cineangiography in 32 cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Yeon, Kyung Mo; Park, Jae Hyung; Han, Man Chung; Yoon, Yong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1983-06-15

    Total 32 cases of pulmonary atresia were diagnosed radiographically at Seoul National University Hospital from March, 1979 to August 1982. Some characteristic radiological findings were analyzed in chest PA and cineangiographies. The results were as follows: 1. In the evaluation of chest PA, cardiomegaly was noticed in 16 cases, dextrocardia in 8 cases, elevated cardiac apex in 7 cases and right-sided aortic arch in 6 cases. The pulmonary vascularties were mildly decreased in 20 cases, markedly decreased in 9 cases and decreased with reticular pattern in 3 cases. 2. As final diagnoses after cineangiography, pulmonary atresia was associated with Tetralogy of Fallot variant in 17 cases, transposition of great vessels in 7 cases, single ventricle in 5 cases, tricuspid atresia in 2 cases and intact ventricular septum in 1 case. 3. The classification according to the pattern of pulmonary artery is main pulmonary trunk with PDA(Type Ia) in 10 cases, pulmonary arterial confluence with PDA (Type Ib) in 10 cases, no pulmonary arterial confluence with PDA (Type Ic) in 5 cases, main pulmonary trunk without PDA (Type IIa) in 0 case, pulmonary arterial confluence without PDA (Type IIb) in 5 cases, and no pulmonary arterial confluence without PDA ( Type IIc) in 2 cases. 4. Pulmonary wedge venography was done and successful in 8 cases. Among them, confluence between right and left pulmonary arteries was noticed in 5 cases. 5. Biventricular cineangiograpy and/or pulmonary wedge venography, if necessary, is essential for the accurate diagnosis of pulmonary atresia to demonstrate detailed anatomy of pulmonary artery.

  8. Radiological evaluation of pulmonary atresia: An analysis of cineangiography in 32 cases

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Yeon, Kyung Mo; Park, Jae Hyung; Han, Man Chung; Yoon, Yong Soo

    1983-01-01

    Total 32 cases of pulmonary atresia were diagnosed radiographically at Seoul National University Hospital from March, 1979 to August 1982. Some characteristic radiological findings were analyzed in chest PA and cineangiographies. The results were as follows: 1. In the evaluation of chest PA, cardiomegaly was noticed in 16 cases, dextrocardia in 8 cases, elevated cardiac apex in 7 cases and right-sided aortic arch in 6 cases. The pulmonary vascularties were mildly decreased in 20 cases, markedly decreased in 9 cases and decreased with reticular pattern in 3 cases. 2. As final diagnoses after cineangiography, pulmonary atresia was associated with Tetralogy of Fallot variant in 17 cases, transposition of great vessels in 7 cases, single ventricle in 5 cases, tricuspid atresia in 2 cases and intact ventricular septum in 1 case. 3. The classification according to the pattern of pulmonary artery is main pulmonary trunk with PDA(Type Ia) in 10 cases, pulmonary arterial confluence with PDA (Type Ib) in 10 cases, no pulmonary arterial confluence with PDA (Type Ic) in 5 cases, main pulmonary trunk without PDA (Type IIa) in 0 case, pulmonary arterial confluence without PDA (Type IIb) in 5 cases, and no pulmonary arterial confluence without PDA ( Type IIc) in 2 cases. 4. Pulmonary wedge venography was done and successful in 8 cases. Among them, confluence between right and left pulmonary arteries was noticed in 5 cases. 5. Biventricular cineangiograpy and/or pulmonary wedge venography, if necessary, is essential for the accurate diagnosis of pulmonary atresia to demonstrate detailed anatomy of pulmonary artery

  9. Pulmonary complications of liver transplantation: radiological appearance and statistical evaluation of risk factors in 300 cases

    International Nuclear Information System (INIS)

    Golfieri, R.; Giampalma, E.; D'Arienzo, P.; Maffei, M.; Muzzi, C.; Tancioni, S.; Gavelli, G.; Morselli Labate, A.M.; Sama, C.; Jovine, E.; Grazi, G.L.; Mazziotti, A.; Cavallari, A.

    2000-01-01

    The aim of this study was to evaluate the incidence, radiographic appearance, time of onset, outcome and risk factors of non-infectious and infectious pulmonary complications following liver transplantation. Chest X-ray features of 300 consecutive patients who had undergone 333 liver transplants over an 11-year period were analysed: the type of pulmonary complication, the infecting pathogens and the mean time of their occurrence are described. The main risk factors for lung infections were quantified through univariate and multivariate statistical analysis. Non-infectious pulmonary abnormalities (atelectasis and/or pleural effusion: 86.7%) and pulmonary oedema (44.7%) appeared during the first postoperative week. Infectious pneumonia was observed in 13.7%, with a mortality of 36.6%. Bacterial and viral pneumonia made up the bulk of infections (63.4 and 29.3%, respectively) followed by fungal infiltrates (24.4%). A fairly good correlation between radiological chest X-ray pattern, time of onset and the cultured microorganisms has been observed in all cases. In multivariate analysis, persistent non-infectious abnormalities and pulmonary oedema were identified as the major independent predictors of posttransplant pneumonia, followed by prolonged assisted mechanical ventilation and traditional caval anastomosis. A ''pneumonia-risk score'' was calculated: low-risk score ( 3.30) population. The ''pneumonia-risk score'' identifies a specific group of patients in whom closer radiographic monitoring is recommended. In addition, a highly significant correlation (p<0.001) was observed between pneumonia-risk score and the expected survival, thus confirming pulmonary infections as a major cause of death in OLT recipients. (orig.)

  10. Comparative evaluation of image quality in computed radiology systems using imaging plates with different usage time

    International Nuclear Information System (INIS)

    Lazzaro, M.V.; Luz, R.M. da; Capaverde, A.S.; Silva, A.M. Marques da

    2015-01-01

    Computed Radiology (CR) systems use imaging plates (IPs) for latent image acquisition. Taking into account the quality control (QC) of these systems, imaging plates usage time is undetermined. Different recommendations and publications on the subject suggest tests to evaluate these systems. The objective of this study is to compare the image quality of IPs of a CR system, in a mammography service, considering the usage time and consistency of assessments. 8 IPs were used divided into two groups: the first group included 4 IPs with 3 years of use (Group A); the second group consisted of 4 new IPs with no previous exposure (Group B). The tests used to assess the IP's quality were: Uniformity, Differential Signal to Noise Ratio (SDNR), Ghost Effect and Figure of Merit (FOM). Statistical results show that the proposed tests are shown efficient in assessing the conditions of image quality obtained in CR systems in mammography and can be used as determining factors for the replacement of IP's. Moreover, comparing the two sets of IP, results led to the replacement of all the set of IP’s with 3 years of use. This work demonstrates the importance of an efficient quality control, not only with regard to the quality of IP's used, but in the acquisition system as a whole. From this work, these tests will be conducted on an annual basis, already targeting as future work, monitoring the wear of IP's Group B and the creation of a baseline for analysis and future replacements. (author)

  11. Rheumatoid arthritis of the knee - radiological evaluation; Primaere chronische Polyarthritis am Kniegelenk

    Energy Technology Data Exchange (ETDEWEB)

    Rand, T. [Wien Univ. (Austria). Einrichtung fuer Magnetresonanz; Breitenseher, M. [Wien Univ. (Austria). Einrichtung fuer Magnetresonanz; Haller, J. [Hanusch Krankenhaus Wien (Austria). Abt. fuer Radiodiagnostik; Graninger, W. [Abt. fuer Innere Medizin, Univ. Wien, Ludwig Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik (Austria); Imhof, H. [Wien Univ. (Austria). Einrichtung fuer Magnetresonanz; Trattnig, S. [Wien Univ. (Austria). Einrichtung fuer Magnetresonanz

    1996-08-01

    Rheumatoid arthritis is a chronic, multisystemic disease. The characteristic feature is persistent inflammatory synovitis. The knee joint is commonly involved with synovial hypertrophy, chronic effusion, and frequently ligamentous laxity. Pain and swelling behind the knee may be caused by extension of inflamed synovium into the popliteal space (Baker`s cyst). Plain radiographs of the knee joint remain the basic radiological procedure, although early in the disease they might not provide significant changes. Sonography sufficiently reveals synovial fluid and Baker cysts, but cannot be recommended for evaluation of synovial proliferations or pannus formation. Computer tomography has only limited indications and may be used for the evaluation of subtle erosive lesions or the quantitation of osteoporotic changes. Magnetic resonance imaging has shown excellent visualization of cartilage, fluid, synovium and soft tissues and is the method of choice for the demonstration of early affection and the evaluation of panus activity and therapy control. With daministration of contrast agents (gadolinium), dynamic studies may demonstrate inflammatory activity. Modern MR sequences, such as T1 SE `fat sat` or magnetization transfer, further improve the discrimination of cartilage, pannus and synovial fluid. (orig.) [Deutsch] Die chronische Polyarthritis (CP) ist eine multisystematische Erkrankung und wird charakteristischerweise von einer persistierenden inflammatorischen Synovitis begleitet. Das Kniegelenk ist das haeufigste einzeln betroffene Gelenk, seine Affektion manifestiert sich zumeist mit synovialer Hypertrophie, chronischen Erguessen und oftmals auch Bandinstabilitaet. Schmerzen sowie Schwellungen in den dorsalen Weichteilen sind oft durch Vordringen inflammatorischer Synovia oder Ergussansammlungen bedingt (Baker-Zyste). Das konventionelle Roentgenbild bildet zwar einen Grundpfeiler in der CP-Diagnostik, zeigt jedoch oft erst bei fortgeschrittenem Krankheitsverlauf

  12. Radiographic evaluation of caudal vena cava size in dogs

    International Nuclear Information System (INIS)

    Lehmkuhl, L.B.; Bonagura, J.D.; Biller, D.S.; Hartman, W.M.

    1997-01-01

    Dilation of the caudal vena cava (CVC) on lateral thoracic radiographs is often interpreted as suggestive of right-sided congestive heart failure, To quantitate the clinical utility of evaluating CVC size as an indicator of right-sided heart disease, we compared the ratio of the diameter of the CVC as measured on a left lateral thoracic radiograph to the descending aorta (Ao), length of the thoracic vertebra above the tracheal bifurcation (VL), and width of the right fourth rib (R4) in 35 dogs with right heart disease and 35 control dogs, Each CVC ratio(CVC/Ao, CVC/VL, CVC/R4) was statistically larger in dogs with right heart disease, Response operating characteristic curves and likelihood ratios were used to determine ratios helpful in identifying dogs with right heart disease. A CVC/Ao > 1.50, CVC/VL > 1.30, or CVC/R4 > 3.50 are strongly suggestive of a right-sided heart abnormality in a patient

  13. Radiological evaluation of response to treatment: Application to metastatic renal cancers receiving anti-angiogenic treatment

    International Nuclear Information System (INIS)

    Ammari, S.; Hernigou, A.; Grataloup, C.; Thiam, R.; Cuenod, C.A.; Siauve, N.; Fournier, L.S.; Oudard, S.; Medioni, J.

    2014-01-01

    Targeted therapies have considerably improved the prognosis of patients with metastatic renal cancer (mRCC) but there are no reliable response assessment criteria reflecting the clinical benefits, because there is no regression in size, or it is delayed. Such criteria would help early identification of non-responders, who would then benefit from a change of treatment, and would avoid their being subjected to unnecessary side effects related to the treatment. We will review the imaging techniques currently available for evaluating tumour response in mRCC patients, including the response evaluation criteria in solid tumours (RECIST), the Choi criteria, the modified Choi criteria, and the CT size and attenuation criteria (SACT). We will also discuss functional imaging techniques, which are based on the physiological characteristics of the tumours, such as perfusion CT, magnetic resonance imaging or ultrasound (DCE-CT, DCE-MRI, DCE-US), diffusion MRI, BOLD MRI and new positron emission tomography (PET) tracers. It is not possible at present to propose a unanimously acknowledged criterion for evaluating tumour response to targeted therapy. However, there is a real need for this according to oncologists and the pharmaceutical industry, and radiologists need to be involved in reflecting on the subject. (authors)

  14. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    International Nuclear Information System (INIS)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed

  15. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed.

  16. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  17. The pituitary gland in patients with Langerhans cell histiocytosis: a clinical and radiological evaluation.

    Science.gov (United States)

    Kurtulmus, Neslihan; Mert, Meral; Tanakol, Refik; Yarman, Sema

    2015-04-01

    Langerhans cell histiocytosis (LCH) is a rare disease in which the most common endocrine manifestation is diabetes insipidus (DI). Data on anterior pituitary function in patients with LCH are limited. Thus, the present study investigated anterior pituitary function in LCH patients with DI via the evaluation of clinical and radiological findings at disease onset and during follow-up. The present study retrospectively evaluated nine patients with LCH (five males and four females). All diagnoses of LCH were made following histological and/or immunophenotypic analyses of tissue biopsies, bronchoalveolar lavage, or cerebrospinal fluid (CSF). Basal and, if necessary, dynamic pituitary function tests were used to assess anterior pituitary function, and magnetic resonance imaging (MRI) scans were used to image the pituitary. The LCH treatment modality was based on organ involvement. The mean age at onset of DI was 27.6 years (range 15-60 years). One patient (11%) exhibited single organ involvement, while eight patients (89%) displayed multisystem organ involvement. On admittance, one patient had hypogonadotropic hypogonadism, one patient exhibited panhypopituitarism [hypogonadotropic hypogonadism, central hypothyroidism, hypocortisolism, and growth hormone (GH) deficiency], and four patients (44%) displayed hyperprolactinemia. The MRI data revealed infundibular enlargement in seven patients (78%), a thalamic mass in one patient (11%), and the absence of the bright spot in all patients. A single patient (11%) showed a mass in the pons that had a partially empty sella. The patients were treated with radiation therapy (RT), chemotherapy (CT), or a combination of both (RT+CT) and were followed up for a median of 91.8 months (range 2-318 months). Seven patients were assessed during the follow-up period, of whom four patients (57.1%) developed anterior pituitary hormone deficiency, three (43%) were diagnosed with GH deficiency, and one (14%) exhibited gonadotropin deficiency

  18. Baseline study of radiology services for the purpose of PACS evaluation

    International Nuclear Information System (INIS)

    Mun, S.K.; Benson, H.; Welsh, C.; Elliott, L.P.; Davros, W.

    1988-01-01

    This paper reports initial results of a radiology department baseline study of workload and data flow patterns for image generation, film library activities, report generation reporting activities at the film alternators and report transcription and validation. The authors analyze the film based operations prior to full implementation of the image management and communication system. The baseline study topics are examined

  19. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  20. Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

    International Nuclear Information System (INIS)

    Jaswal, Jasbir; D'Souza, Leah; Johnson, Marjorie; Tay, KengYeow; Fung, Kevin; Nichols, Anthony; Landis, Mark; Leung, Eric; Kassam, Zahra; Willmore, Katherine; D'Souza, David; Sexton, Tracy; Palma, David A.

    2015-01-01

    Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp

  1. Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

    Energy Technology Data Exchange (ETDEWEB)

    Jaswal, Jasbir [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); D' Souza, Leah; Johnson, Marjorie [Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada); Tay, KengYeow [Department of Diagnostic Radiology, London Health Sciences, London, Ontario (Canada); Fung, Kevin; Nichols, Anthony [Department of Otolaryngology, Head & Neck Surgery, Victoria Hospital, London, Ontario (Canada); Landis, Mark [Department of Diagnostic Radiology, London Health Sciences, London, Ontario (Canada); Leung, Eric [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); Kassam, Zahra [Department of Diagnostic Radiology, St. Joseph' s Health Care London, London, Ontario (Canada); Willmore, Katherine [Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada); D' Souza, David; Sexton, Tracy [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); Palma, David A., E-mail: david.palma@lhsc.on.ca [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada)

    2015-03-15

    Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp

  2. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  3. Evaluation of radiological impacts of tenorm in the Tunisian petroleum industry

    International Nuclear Information System (INIS)

    Hrichi, Hajer; Baccouche, Souad; Belgaied, Jamel-Eddine

    2013-01-01

    The health impacts associated with uncontrolled release of TENORM in products and wastes released in the petroleum industry are of great concern. In this study, evaluation of TENORM in the Tunisian petroleum products and wastes is presented. Fourteen products samples, twelve waste samples and three samples from the surrounding environment were collected from the Tunisian Refinery STIR site and from two onshore production oilfields. The activity concentrations of 232 Th, 226 Ra and 40 K for all samples were determined using gamma-ray spectrometry with High Purity Germanium (HPGe) detector. The activity concentrations of 224 Ra were calculated only for scale samples. The radium equivalent activity, external and internal hazard indices, absorbed doses rates in air and annual effective dose were also estimated. It was noticed that maximum value of Ra eq activity was found to be 398 Bq/kg in scale (w8) collected from an onshore production oilfield which exceeds the maximum Ra eq value of 370 Bq/kg recommended for safe use. All hazard indices indicated that scale samples (w6, w7, w8 and w11) could be a significant waste problem especially sample (w8). In this study, the radium isotopic data were used to provide an estimate of scale samples ages by the use of the 224 Ra/ 228 Ra activity ratio dating method. Ages of collected scales were found to be in the range 0.91–2.4 years. In this work, radioactivity (NORM contamination) in samples collected from the refinery STIR are showed to be insignificant if compared to those from onshore oilfield production sites. - Highlights: ► We followed 232 Th, 226 Ra and 40 K concentrations in Tunisian petroleum products and wastes. ► Radium isotopic data were used to estimate the age of scales deposited in the petroleum production equipments. ► Samples collected from refinery installation did not represent radiological risk. ► Scale samples collected from oil fields installation exceeded UNSCEAR rules.

  4. Evaluation and assessment methodology, standards, and procedures manual of the United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Kerns, K.C.; Burson, Z.G.; Smith, J.M.; Blanchard, R.L.

    2000-01-01

    In the event of a major radiological emergency, the U.S. Federal Radiological Emergency Response Plan authorises the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC). The FRMAC is established to co-ordinate the Federal off-site monitoring and assessment activities, and is comprised of representatives from several Federal agencies and Department of Energy contractors who provide assistance to the state(s) and Lead Federal Agency. The Evaluation and Assessment (E and A) Division of the FRMAC is responsible for receiving, storing, and interpreting environmental surveillance data to estimate the potential health consequences to the population in the vicinity of the accident site. The E and A Division has commissioned the preparation of a methodology and procedures manual which will result in a consistent approach by Division members in carrying out their duties. The first edition of this manual is nearing completion. In this paper, a brief review of the structure of the FRMAC is presented, with emphasis on the E and A Division. The contents of the E and A manual are briefly described, as are future plans for its expansion. (author)

  5. Preparation, conduct and evaluation of exercises to test preparedness for a nuclear or radiological emergency. Emergency preparedness and response

    International Nuclear Information System (INIS)

    2005-04-01

    The aim of this publication is to serve as a practical tool for the preparation, conduct and evaluation of exercises to test preparedness for response to a nuclear or radiological emergency. It fulfils in part the functions assigned to the IAEA under Article 5.a(ii) of the Convention on Assistance in Case of a Nuclear Accident or Radiological Emergency (Assistance Convention), namely, to collect and disseminate to States Parties and Member States information concerning the methodologies, techniques and available results of research on such emergencies. To ensure effective response to radiation emergencies when needed, provisions should be made for regular training of emergency response personnel. As stated in Preparedness and Response for a Nuclear or Radiological Emergency (Safety Requirements, Safety Standard Series No. GS-R-2), 'The operator and the response organizations shall make arrangements for the selection of personnel and training to ensure that the personnel have the requisite knowledge, skills, abilities, equipment, procedures and other arrangements to perform their assigned response functions'. A further requirement is that 'Exercise programmes shall be conducted to ensure that all specified functions required to be performed for emergency response and all organizational interfaces for facilities in threat category I, II or III and the national level programmes for threat category IV or V are tested at suitable intervals'. In 2004 the IAEA General Conference, in resolution GC(48)/RES/10 encouraged Member States to 'implement the Safety Requirements for Preparedness and Response to a Nuclear or Radiological Emergency'. This document is published as part of the IAEA Emergency Preparedness and Response Series to assist in meeting these requirements and to fulfil Article 5 of the Assistance Convention. It was developed based on a number of assumptions about national and local capabilities. Therefore, the exercise structure, terms and scenarios must be

  6. Finding and evaluating potential radiological problems in the vicinity of uranium milling sites

    International Nuclear Information System (INIS)

    Goldsmith, W.A.; Yates, W.G.

    1982-01-01

    The Oak Ridge National Laboratory (ORNL) has been performing radiological surveys at former uranium and thorium milling and processing sites since 1975. Tailings at inactive milling sites usually have a low frequency of human occupancy but continuously generate 222 Rn into the atmosphere. Thus, independent 222 Rn surveys are conducted at the inactive mill sites and their environs by the Mound Facility. Measurements of airborne 222 Rn and 222 Rn flux are made on the sites to define the tailings source term. Concurrently with these measurements, an ambient 222 Rn monitoring network is established off-site and a meteorological station is established at or near the mill site. Unfortunately, tailings are not always confined to the milling site. Radioactivity can migrate to areas outside of site boundaries by wind and water erosion, groundwater transport, spillage of incoming ore, and removal of tailings or other material for private purposes. In order to identify and assess off-site radioactivity on properties in the vicinity of milling sites, a combination of aerial and ground-level radiological monitoring techniques are used. The ground mobile gamma-ray scan is conducted using a vehicle equipped with sensitive gamma-ray detectors. The detectors are shielded so that gamma radiation input is viewed through only one side of the vehicle. This system is capable of precisely locating properties which have anomalously high gamma radiation levels caused by the presence of tailings. Subsequently, these properties are identified as candidate vicinity properties and are scheduled for radiological surveys subject to the property owner's consent. The comprehensive radiological surveys conducted at these vicinity properties determine the amount, type, and location of tailings materials

  7. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  8. Evaluation of soluble organic compounds generated by radiological degradation of asphalt

    International Nuclear Information System (INIS)

    Fukumoto, M.; Nishikawa, Y.; Kagawa, A.; Kawamura, K.

    2000-12-01

    The soluble organic compounds generated by radiological degradation of asphalt (γ ray) were confirmed as a part of influence of the bituminized waste degradation in the TRU waste repository. Especially, the influence of the nitrate was focused on. As a result, the concentration of the soluble organic compounds generated by radiological degradation of asphalt (10 MGy, γ ray which is correspond to absorbed dose of asphalt for 1,000,000 years) were lower (each formic acid: about 50 mg/dm 3 , acetic acid: about 30 mg/dm 3 and oxalic acid: about 2 mg/dm 3 ) than that of the formic acid, the acetic acid and the oxalic acid which Valcke et al. had shown (the influence of the organic at the solubility examination which uses Pu and Am). Moreover, the change in the concentration of TOC and the soluble organic compounds (formic acid, acetic acid and oxalic acid) is little under the existence of nitrate ion. That is, the formic acid and acetic acid which can be organic ligands were generated little by oxidative decomposition of asphalt in the process that nitrate ion becomes nitride ion by radiation. The influence of the soluble organic compounds by the radiological degradation of the asphalt (γ ray) on adsorption and solubility by the complexation of radionuclides in the performance assessment can be limited. (author)

  9. Triple osteotomy for the correction of severe hallux valgus deformity: Patient reported outcomes and radiological evaluation.

    Science.gov (United States)

    Booth, Sean; Bhosale, Abhijit; Mustafa, Abubakar; Shenoy, Ravi; Pillai, Anand

    2016-08-01

    Symptomatic Hallux valgus can be treated with metatarsal osteotomy combined with proximal phalangeal osteotomy, however this might not be sufficient to treat severe HV deformities. Fifteen feet in eleven female patients treated with double first metatarsal and proximal phalanx osteotomies without lateral release were prospectively studied and outcome measures including radiological angles and validated patient reported outcome scores collected. Mean radiological follow up was 15 months and PROMs data 17 months. Mean hallux valgus and intermetatarsal angles were corrected from 45 to 24.7° and 18.7 to 7.4° respectively. There was an eight degree recurrence of hallux valgus angle. There was no wound problems, non-unions or evidence of avascular necrosis. The EQ-5D descriptive index showed a non-statistically significant improvement. All three elements of the MOxFQ score showed a statistically significant improvement: Forefoot pain (59-26.8), Walking and Stability (49.9-29.6) and Social Interaction (56.4-33.1) CONCLUSION: Triple osteotomy, without a lateral soft tissue release, leads to good radiological and functional outcomes in those with severe hallux valgus deformity. Patients need to be warned of the recovery time and potential for future metalwork removal. The risk of early recurrence suggests that a lateral release should be included in order to maintain a long lasting correction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Evaluation of Ventricle Size Measurements in Infants by Pediatric Emergency Medicine Physicians.

    Science.gov (United States)

    Halm, Brunhild M; Leone, Tina A; Chaudoin, Lindsey T; McKinley, Kenneth W; Ruzal-Shapiro, Carrie; Franke, Adrian A; Tsze, Daniel S

    2018-06-05

    The identification of hydrocephalus in infants by pediatric emergency medicine (PEM) physicians using cranial point-of-care ultrasound (POCUS) has not been evaluated. We aimed to conduct a pilot/proof-of-concept study to evaluate whether PEM physicians can identify hydrocephalus (anterior horn width >5 mm) in 15 infants (mean 69 ± 42 days old) from the neonatal intensive care unit using POCUS. Our exploratory aims were to determine the test characteristics of cranial POCUS performed by PEM physicians for diagnosing hydrocephalus and the interrater reliability between measurements made by the PEM physicians and the radiologist. Depending on the availability, 1 or 2 PEM physicians performed a cranial POCUS through the open anterior fontanel for each infant after a 30-minute didactic lecture to determine the size of the left and right ventricles by measuring the anterior horn width at the foramen of Monroe in coronal view. Within 1 week, an ultrasound (US) technologist performed a cranial US and a radiologist determined the ventricle sizes from the US images; these measurements were the criterion standard. A radiologist determined 12 of the 30 ventricles as hydrocephalic. The sensitivity and specificity of the PEM physicians performed cranial POCUS was 66.7% (95% confidence interval [CI], 34.9%-90.1%) and 94.4% (95% CI, 72.7%-99.9%), whereas the positive and negative predictive values were 88.9% (95% CI, 53.3%-98.2%) and 81.0% (95% CI, 65.5%-90.5%), respectively. The interrater reliability between the PEM physician's and radiologist's measurements was r = 0.91. The entire POCUS examinations performed by the PEM physicians took an average of 1.5 minutes. The time between the cranial POCUS and the radiology US was, on average, 4 days. While the PEM physicians in our study were able to determine the absence of hydrocephalus in infants with high specificity using cranial POCUS, there was insufficient evidence to support the use of this modality for identifying

  11. Evaluation of size dependent design shear strength of reinforced ...

    Indian Academy of Sciences (India)

    to the development of the size dependent models on the shear strength in ... predict the diagonal cracking strength and the ultimate shear strength of RC ... ing strength of normal beams was by Zsutty (1968) based on the data base available without .... The comparison of the calculated shear strength of the beams is shown.

  12. Radiological findings in Wolfram syndrome

    International Nuclear Information System (INIS)

    Hadidy, Azmy M.; Jarrah, Nadim S.; Al-Till, Maha I.; Ajlouni, Kamal M.; El-Shanti, Haten E.

    2004-01-01

    To determine the precise radiologic findings in Wolfram syndrome (WFS) patients using objective techniques in order to better define the reference population for the clinicl evaluation. 16 patients (6 males, 10 female) with WFS found in 4 families were included in this study.14 patients with WFS-2 came from 3 families while 2 patients with EFS-1 came from one family. All patients were studied at Jordan University Hospital, Amman,Jordan from January 2001 to January 2003 by definite radiologic techniques as part of a thorough clinical comprehesive assesment. These incclude intravenous urography, abdominal and pelvic ultrasonography, barium meal, upper gastrointestinal endoscopy and magnetic resonance imaging with and without contrasts to the brain and the pituitary glands.5 of the female ptients had a small uterus. Spina bifida was found in 7, hydronephrosis in 9 and hydroureter in 5 patiets. Peptic ulcer was detected in 10 out of 14 available patients and helicobacter pylori in 7 out of 16 patients. Atrophy was detected was detected in all brains, 9 brain stems, 12 cerebellums and 14 optic tracts of all patients. The size of pituitary glands was variable. The particular radiological assesment of the patients with WFS proved that, urinary tract dialtation was detected in WFS-1and WFS-2 patients though all WFS-2 patients.No significant radiologic difference was between patients with WFS-1 and WFS-2. (author)

  13. Radiology Teaching Files on the Internet

    International Nuclear Information System (INIS)

    Lim, Eun Chung; Kim, Eun Kyung

    1996-01-01

    There is increasing attention about radiology teaching files on the Internet in the field of diagnostic radiology. The purpose of this study was to aid in the creation of new radiology teaching file by analysing the present radiology teaching file sites on the Internet with many aspects and evaluating images on those sites, using Macintosh II ci compute r, 28.8kbps TelePort Fax/Modem, Netscape Navigator 2.0 software. The results were as follow : 1. Analysis of radiology teaching file sites (1) Country distribution was the highest in USA (57.5%). (2) Average number of cases was 186 cases and radiology teaching file sites with search engine were 9 sites (22.5%). (3) At the method of case arrangement, anatomic area type and diagnosis type were found at the 10 sites (25%) each, question and answer type was found at the 9 sites (22.5%). (4) Radiology teaching file sites with oro-maxillofacial disorder were 9 sites (22.5%). (5) At the image format, GIF format was found at the 14 sites (35%), and JPEG format found at the 14 sites (35%). (6) Created year was the highest in 1995 (43.7%). (7) Continuing case upload was found at the 35 sites (87.5%). 2. Evaluation of images on the radiology teaching files (1) Average file size of GIF format (71 Kbyte) was greater than that of JPEG format (24 Kbyte). (P<0.001) (2) Image quality of GIF format was better than that of JPEG format. (P<0.001)

  14. Use and experience of radiological evaluation tools for the early phase during nuclear emergency exercises in Belgium

    International Nuclear Information System (INIS)

    Sohier, A.; Ruts, J.; Hardeman, F.

    2003-01-01

    Full text: The Royal Decree on 'The Emergency Plan for Nuclear Risks an the Belgian Territory' describes the role and tasks of the different stakeholders involved in case of a nuclear crisis affecting Belgium. The crisis is managed from within the Governmental Crisis Coordination Centre in Brussels where various functional cells meet according to the notification and alarm levels. Decisions about countermeasures are taken at federal level by a Coordination Committee headed by the Minister of Interior. These may be preceded by rapid decision making initiated at provincial and local levels in case of an imminent radiological threat. An information cell stands for the release of official information and instructions to the media and the public and for the monitoring of public reactions. A crucial step for a sound intervention decision making is the radiological evaluation process. The evaluation cell is responsible to gather all relevant information, to analyse it and to give advice on the best intervention strategy to the coordination committee. The primary source of information originates from the nuclear operator which must legally transmit recurrent information about the actual and forecasted status and release of the plant, the actual meteorological situation, the expected off-site radiological consequences and, if possible, environmental measurements. The evaluation cell is assisted by the measurement cell which elaborates and executes a monitoring campaign based an advice of the evaluation cell. The national monitoring network called Telerad provides another input of information. In consultation with the authorities, a rather simple yet highly flexible radiological evaluation tool to be used by the two main nuclear power plants in Belgium (Doel and Tihange) during the early phase has been developed by SCK-CEN, i.e. Noodplan Kerncentrale Doel and Plan d'Urgence Zone de Production Nucleaire de Tihange. The principal module allows computing in real-time the main

  15. Evaluation of dose equivalent to the people accompanying patients in diagnostic radiology using MCNP4C Monte Carlo code

    International Nuclear Information System (INIS)

    Mehdizadeh, S.; Faghihi, R.; Sina, S.; Zehtabian, M.

    2007-01-01

    Complete text of publication follows. Objective: X rays used in diagnostic radiology contribute a major share to population doses from man-made sources of radiation. In some branches of radiology, it is necessary that another person stay in the imaging room and immobilize the patient to carry out radiological operation. ICRP 70 recommends that this should be done by parents or accompanying nursing or ancillary personnel and not in any case by radiation workers. Methods: Dose measurements were made previously using standard methods employing LiF TLD-100 dosimeters. A TLD card was installed on the main trunk of the body of the accompanying people where the maximum dose was probable. In this research the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C) is used to calculate the equivalent dose to the people accompanying patients exposed to radiation scattered from the patient (Without protective clothing). To do the simulations, all components of the geometry are placed within an air-filled box. Two homogeneous water phantoms are used to simulate the patient and the accompanying person. The accompanying person leans against the table at one side of the patient. Finally in case of source specification, only the focus of the X-ray tube is modelled, i.e. as a standard MCNP point source emitting a cone of photons. Photon stopping material is used as a collimator model to reduce the circular cross section of the cone to a rectangle. The X-ray spectra to be used in the MCNP simulations are generated with spectrum generator software, taking the X-ray voltage and all filtration applied in the clinic as input parameters. These calculations are done for different patient sizes and for different radiological operations. Results: In case of TL dosimetry, for a group of 100 examinations, the dose equivalents ranged from 0.01 μsv to 0.13 msv with the average of 0.05 msv. The results are seen to be in close agreement with Monte Carlo simulations

  16. Assumptions used for evaluating the potential radiological consequences of a less of coolant accident for pressurized water reactors - June 1974

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    Section 50.34 of 10 CFR Part 50 requires that each applicant for a construction permit or operating license provide an analysis and evaluation of the design and performance of structures, systems, and components of the facility with the objective of assessing the risk to public health and safety resulting from operation of the facility. The design basis loss of coolant accident is one of the postulated accidents used to evaluate the adequacy of these structures, systems, and components with respect to the public health and safety. This guide gives acceptable assumptions that may be used in evaluating the radiological consequences of this accident for a pressurized water reactor. In some cases, unusual site characteristics, plant design features, or other factors may require different assumptions which will be considered on an individual case basis. The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position

  17. Assumptions used for evaluating the potential radiological consequences of a loss of coolant accident for boiling water reactors - June 1974

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    Section 50.34 of 10 CFR Part 50 requires that each applicant for a construction permit or operating license provide an analysis and evaluation of the design and performance of structures, systems, and components of the facility with the objective of assessing the risk to public health and safety resulting from operation of the facility. The design basis loss of coolant accident is one of the postulated accidents used to evaluate the adequacy of these structures, systems, and components with respect to the public health and safety. This guide gives acceptable assumptions that may be used in evaluating the radiological consequences of this accident for a pressurized water reactor. In some cases, unusual site characteristics, plant design features, or other factors may require different assumptions which will be considered on an individual case basis. The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position

  18. Finding and evaluating potential radiological problems in the vicinity of uranium milling sites

    International Nuclear Information System (INIS)

    Goldsmith, W.A.; Yates, W.G.

    1982-01-01

    Tailings at inactive milling sites usually have a low frequency of human occupancy but continuously generate 222 Rn into the atmosphere. Measurements of airborne 222 Rn and 222 Rn flux are made on the sites to define the tailings source term. Concurrently with these measurements, an ambient 222 Rn monitoring network is established off-site and a meteolrololgical station is established at or near the mill site. Radioactivity can migrate to areas outside of site boundaries by wind and water erosion, groundwater transport, spillage of incoming purposes. In order to identify and assess off-site radioactivity on properties in the vicinity of milling sites, a combination of aerial and ground-level radiological monitoring techniques are used. The ground mobile gamma-ray scan is conducted using a vehicle equipped with sensitive gamma-ray detectors. The detectors are shielded so that gamma radiation input is viewed through only one side of the vehicle. This system is capable of precisely locating properties which have anomalously high gamma radiation levels caused by the presence of tailings. Subsequently, these properties are identified as candidate vicinity properties and are scheduled for radiological surveys subject to the property owner's consent. The comprehensive radiological surveys conducted at these vicinity properties determine the amount, type, and location of tailings materials. Structures on a vicinity property are carefully surveyed to determine the presence or absence of construction-related uses of tailings. If structural uses of tailings are found, air samples are analyzed for 222 Rn progeny, short-term continuous 222 Rn monitoring is instituted, and 222 Rn flux rate from tailings are estimated. If warranted, long-term 222 Rn and progeny measurements are made

  19. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  20. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  1. Evaluation of radiosensitivity and correlation between physical and biological dosimetry in a case of vascular radiology

    International Nuclear Information System (INIS)

    Montoro, A.; Sebastia, N.; Aparici, F.; Candela, C.; Soriano del Castillo, J. M.; Perez, J.; Gras, P.; Cervera, J.; Alonso, O.; Villaescusa, J. I.

    2013-01-01

    The threshold dose required to produce a deterministic effect or even differences in the degree of the effect produced vary between individuals due to idiopathic causes, at the age or underlying disease. According to this work based on the Society of Interventional Radiology and the Guidelines for patient radiation dose management greater than 60 minutes fluoroscopy time management it is an indirect indicator of a significant radiation dose. According to this guide, instructions post procedure in these cases included a follow-up of the patient. (Author)

  2. Evaluation to a long term remediation actions after Goiania radiological accident

    International Nuclear Information System (INIS)

    Rochedo, Elaine R.R.; Rio, Monica A. Pires do; Coutinho, Celia M.C.; Acar, Maria E.D.; Romeiro, Carlos H.

    2000-01-01

    Ten years after the Goiania radiological accident, the results obtained by the IRD Environmental Monitoring Program are compared to the values adopted for establishing the intervention levels at the time of the accident occurrence (1987), and to the values of the parameters obtained by European countries, after the Chernobyl accident. Significant differences were observed in parameter values, particularly, those related to a long term prediction of the contamination behaviour in an urban area. This paper shows the importance of the survey for the environmental behaviour of pollutants in tropical climate conditions. (author)

  3. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    International Nuclear Information System (INIS)

    Jin, Seong Jin; Im, In Chul; Cho, Ji Hwan

    2017-01-01

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality

  4. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Seong Jin [Gammaknife center, Inje University Haeundae Paik Hospital, Busan (Korea, Republic of); Im, In Chul [Dept. of Radiological Science, Dongeui University, Busan (Korea, Republic of); Cho, Ji Hwan [Dept. of Health Care Clinic, Inje University Busan Paik Hospital, Busan (Korea, Republic of)

    2017-03-15

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

  5. Foods Found in the Wild Around Nuclear Sites: An Evaluation of Radiological Impact

    International Nuclear Information System (INIS)

    Green, N.; Wilkins, B.T.; Hammond, D.J.; Davidson, M.F.; Richmond, S.; Brooker, S.

    2001-01-01

    Habit surveys were carried out around four licensed nuclear sites to identify people who collect foodstuffs from the wild (so-called 'free foods'). In total, around 800 collectors were readily identified, most of whom collected more than one free food. The data indicated that estimates of higher than average doses could reasonably be based on the three foodstuffs of most importance. Foods were selected for further study on the basis of either the number of collectors or the amount consumed. The radionuclides of interest were identified using published information on the discharges from each site. The resultant average and higher than average doses were estimated using the site-specific habit data. For all sites, doses from the consumption of free foods were low and of no radiological importance. Assessments based solely on data for cultivated foods would not therefore have underestimated radiological impact significantly. However, given the wide utilisation of free foods found in this study, for rigorous assessments it would be prudent to take account of the consumption of foods from the wild. (author)

  6. The stepchild of intestinal diagnostics. Evaluation of radiological methods to diagnose leiomyomas of the small bowel

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Jenett, M.; Hahn, D.; Mueller, J.G.

    1998-01-01

    Purpose: Various radiological methods to diagnose small bowel neoplasmas and problems of differential diagnosis specially considerating leiomyomas are discussed. Patients and methods: Two patients with leiomyoma of the ileum underwent enteroclysis, computed tomography of the abdomen, intra-arterial DSA and colour Doppler sonography. Another patient with leiomyosarcoma just underwent CT of the abdomen with CT-guided biopsy. Results: Due to the homogenous density and the smooth surface of the tumors in computed tomography and respectively enteroclysis and the presentation of the tumor vascularisation in the angiography and Colour Doppler sonography in both patients a leiomyoma of the small bowel was diagnosed. Postoperatively this diagnosis was histologically confirmed. The CT-findings of the patient with leiomyosarcoma were not suspicious of a malignant tumor. Conclusion: Radiologically it is not possible to determine the dignity of smooth muscle cell tumors safely. That is the reason why the diagnosis has to be achieved operatively. But the histopathological diagnosis based on the mitotic rate may be difficult. Therefore the after care has to be carried out thoroughly. (orig.) [de

  7. Evaluation of natural radioactivity and radiological hazards caused by different marbles of India

    International Nuclear Information System (INIS)

    Ramasamy, V.; Ponnusamy, V.; Hemalatha, J.; Meenakshisundaram, V.; Gajendiran, V.

    2005-01-01

    The samples used in this study are of various coloured varieties of marbles collected from marble dealers. The specific activity concentration of 238 U, 232 Th and 40 K has been determined by gamma ray spectrometry. The materials showed concentrations of 238 U, 232 Th and 40 K which were found to be dramatically variable depending on mineral content and type of formation. Using FTIR and thin section analyses, quartz, feldspar, calcite and mafic minerals present in the samples have been determined quantitatively. From our experimental data, it can be seen that the geochemical parameters such as SiO 2 or mafic minerals or CaCO 3 may be considered to be an appropriate index to select the marbles of low radiological risk. The average specific activities of 40 K are found to be higher than 232 Th, 238 U. The ratio of Th/U was calculated and correlated. Assessment of radiological hazards was made by calculating radium equivalent activities, external and internal hazard indices which were found to vary from 30.92 to 54.45, 0.08 to 0.14 and 0.10 to 0.17 Bq/kg, respectively. The observed values are lower than the recommended limits. (author)

  8. Central giant cell granuloma of the jaws: clinical and radiological evaluation of 22 cases

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhi-Jun; Cai, Yu; Zhao, Yi-Fang [School and Hospital of Stomatology, Wuhan University, Key Laboratory for Oral Biomedical Engineering of Ministry of Education, Wuhan, Hubei (China); Wuhan University, Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan, Hubei (China); Zwahlen, Roger A. [University of Hong Kong, Discipline of Oral and Maxillofacial Surgery, Faculty of Dentistry (China); Zheng, Yun-Fei [School and Hospital of Stomatology, Wuhan University, Key Laboratory for Oral Biomedical Engineering of Ministry of Education, Wuhan, Hubei (China); Wang, Shi-Ping [Wuhan University, Department of Oral and Maxillofacial Radiology, School and Hospital of Stomatology, Wuhan (China)

    2009-09-15

    The objective was to investigate the clinical and radiological characteristics of central giant cell granulomas (CGCGs) of the jaws. A retrospective analysis of a 20-year database was performed regarding both clinical and radiological features of 22 patients affected with CGCGs of the jaws. Fourteen women and 8 men were included with the age range of 7-81 years (mean 31.7 years). Among the 22 lesions, 16 were located in the mandible and 6 in the maxilla. Painless swelling was the most common clinical feature in 18 of all cases. Limited mouth opening was noted in 2 patients where the lesions involved the condyle. Radiographically, 13 lesions were homogeneously osteolytic and 9 lesions were trabeculated. Fifteen lesions were unilocular and 14 lesions presented with well-defined but not sclerotic margins. CT images in 5 patients clearly showed the trabeculation within the lesions. The follow-up ranged from 1.5 to 11 years with a mean period of 5 years. Three out of 9 aggressive and 1 out of 13 nonaggressive lesions developed recurrence. Diagnosis of CGCGs of the jaws depends on both correct interpretation of clinical, radiographic and pathological data. Differentiation between aggressive and nonaggressive CGCGs should be considered to improve individual treatment planning. (orig.)

  9. Central giant cell granuloma of the jaws: clinical and radiological evaluation of 22 cases

    International Nuclear Information System (INIS)

    Sun, Zhi-Jun; Cai, Yu; Zhao, Yi-Fang; Zwahlen, Roger A.; Zheng, Yun-Fei; Wang, Shi-Ping

    2009-01-01

    The objective was to investigate the clinical and radiological characteristics of central giant cell granulomas (CGCGs) of the jaws. A retrospective analysis of a 20-year database was performed regarding both clinical and radiological features of 22 patients affected with CGCGs of the jaws. Fourteen women and 8 men were included with the age range of 7-81 years (mean 31.7 years). Among the 22 lesions, 16 were located in the mandible and 6 in the maxilla. Painless swelling was the most common clinical feature in 18 of all cases. Limited mouth opening was noted in 2 patients where the lesions involved the condyle. Radiographically, 13 lesions were homogeneously osteolytic and 9 lesions were trabeculated. Fifteen lesions were unilocular and 14 lesions presented with well-defined but not sclerotic margins. CT images in 5 patients clearly showed the trabeculation within the lesions. The follow-up ranged from 1.5 to 11 years with a mean period of 5 years. Three out of 9 aggressive and 1 out of 13 nonaggressive lesions developed recurrence. Diagnosis of CGCGs of the jaws depends on both correct interpretation of clinical, radiographic and pathological data. Differentiation between aggressive and nonaggressive CGCGs should be considered to improve individual treatment planning. (orig.)

  10. Radiological evaluation near three old mines of uranium extraction in the department of Creuse - year 2007

    International Nuclear Information System (INIS)

    2007-01-01

    The observations made for three sites of 'Chaumaillat, Ribiere and Grands Champs', demonstrate the existence of an atypical radiological situation which seems marked by the past activities of the mining. If the geochemical context can sometimes be at the origin of abnormalities in sediments and muds, the regional industrial context, conjugated to the strong measured values of uranium, incites us to privilege a human origin to explain these abnormalities. The presence of almost pure uraniums is the result supposed by the past activities of ore treatment on site (lixiviation) to extract the raw material from it (yellow cake) used for the manufacturing of the nuclear fuel. However, this observation on the site of 'Grands Champs' is surprising considering the absence of treatment activity in situ declared by the operator and the absence of residues storage.Given the accessibility of these sites to the public and considering the stop of any device of surveillance, a follow-up study seems necessary to estimate the importance of the radiological abnormalities and their persistent impact on the environment. (N.C.)

  11. Evaluation of entrance skin dose to the skull in diagnostic radiology

    International Nuclear Information System (INIS)

    Mohamed, Anas Ali Elbushari

    2015-12-01

    Diagnostic x-ray radiology is a common diagnostic practice.Despite of its increasing hazard to human beings, imaging procedures should be achieved with less radiation dose and sufficient image quality. The aim of this study was to estimate the entrance skin dose(ESD) for patients undergoing selected diagnostic x-ray examinations in four hospitals.The study included the examinations of the skull; posterior- anterior(PA) and lateral projections. Fifty patients were enrolled in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μGy/mAs) and tube voltage(kVp). The estimated ESDs ranged from 0.0097-0.1846 mGy for skull (PA), 0.0097-0.1399 mGy for skull (LAT). These values were acceptable as compared with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose levels for diagnostic radiology in Sudan.(Author)

  12. Radiologic evaluation of adenoids and tonsils in children with obstructive sleep apnea: Plain films and fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kreplick Fernbach, S.; Brouillette, T.; Riggs, T.W.; Hunt, C.E.

    1983-07-01

    Twenty-six children with obstructive sleep apnea were evaluated by lateral neck radiographs during wakefulness, and by polygraphic monitoring and upper airway fluoreoscopy during natural sleep. Children with craniofacial abnormalities, palatal surgery, and central nervous system disease were excluded from the study. Moderate or marked enlargement of tonsils and adenoids was noted on lateral neck radiographs of 18 of 26 patients. An objective measure of adenoidal enlargement, the adenoidal-nasopharyngeal ratio, correlated well with subjective judgment of adenoidal size but was not generally more useful than subjective estimation. Upper airway fluroescopy demonstrated the site and mechanism of obstruction in all patients. Because all children with moderate to marked adenotonsillar enlargement demonstrated obstruction at the adenoidal or tonsillar level on fluoroscopy, we now screen children with suspected sleep apnea with lateral airway radiographs and polysomnography. Fluoroscopy is reserved for children with mild adenotosillar enlargement, craniofacial dysplasia, prior cleft palate repair, or neuromuscular disorders. These results suggest that the pathogenesis of obstuctive sleep apnea in children involve anatomic factors which narrow the upper airway, sleep-related hypotonia of pharyngeal dilator musculature, and compensatory mechanisms to prevent or alleviate asphyxia.

  13. Radiologic evaluation of adenoids and tonsils in children with obstructive sleep apnea: Plain films and fluoroscopy

    International Nuclear Information System (INIS)

    Kreplick Fernbach, S.; Brouillette, T.; Riggs, T.W.; Hunt, C.E.

    1983-01-01

    Twenty-six children with obstructive sleep apnea were evaluated by lateral neck radiographs during wakefulness, and by polygraphic monitoring and upper airway fluoreoscopy during natural sleep. Children with craniofacial abnormalities, palatal surgery, and central nervous system disease were excluded from the study. Moderate or marked enlargement of tonsils and adenoids was noted on lateral neck radiographs of 18 of 26 patients. An objective measure of adenoidal enlargement, the adenoidal-nasopharyngeal ratio, correlated well with subjective judgment of adenoidal size but was not generally more useful than subjective estimation. Upper airway fluroescopy demonstrated the site and mechanism of obstruction in all patients. Because all children with moderate to marked adenotonsillar enlargement demonstrated obstruction at the adenoidal or tonsillar level on fluoroscopy, we now screen children with suspected sleep apnea with lateral airway radiographs and polysomnography. Fluoroscopy is reserved for children with mild adenotosillar enlargement, craniofacial dysplasia, prior cleft palate repair, or neuromuscular disorders. These results suggest that the pathogenesis of obstuctive sleep apnea in children involve anatomic factors which narrow the upper airway, sleep-related hypotonia of pharyngeal dilator musculature, and compensatory mechanisms to prevent or alleviate asphyxia. (orig.)

  14. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  15. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  16. Pediatric radiology

    International Nuclear Information System (INIS)

    Kirkpatrick, J.A. Jr.

    1985-01-01

    Computed tomography has made possible the excellent and basic work having to do with the characteristics of the trachea, its caliber, shape, and length in children. Another group of articles has to do with interventional pediatric radiology. This year there were a number of articles of which only a sample is included, dealing with therapeutic procedures involving drainage of abscesses, angioplasty, nephrostomy, therapeutic embolization, and the removal of esophageal foreign bodies. Obviously, there is no reason to think that techniques developed for the adult may not be applicable to the infant or child; also, there is no reason to believe that processes peculiar to the child should not be amenable to intervention, for instance, use of embolization of hepatic hemangioma and transluminal balloon valvuloplasty for pulmonary valvular stenosis. Among the reports and reviews, the author would add that sonography remains a basic imaging technique in pediatric radiology and each year its application broadens. For example, there is an excellent article having to do with sonography of the neonatal and infant hip and evaluation of the inferior vena cava and the gallbladder. Nuclear medicine continues to play a significant role in diagnosis, which is featured in two articles concerned with problems of the hip

  17. Spiral computed tomography during arterial portography of the liver: correlations between radiological and intraoperative findings and evaluation of operability

    International Nuclear Information System (INIS)

    Layer, G.; Runge, I.; Conrad, R.; Pauleit, D.; Jaeger, U.; Schild, H.H.; Gallkowski, U.; Wolff, M.; Hirner, A.

    1999-01-01

    Purpose: To evaluate the accuracy of spiral computed tomography during arterial portography (SCTAP) in the detection, localization, and resectablility of liver tumors in a correlative study between radiology and intraoperative findings. Method and Materials: Retrospectively, SCTAP images of 168 consecutive patients before liver tumor resection were analyzed. The SCTAP studies (100 ml Iopromid 300 by automated injector with a flow of 3 ml/s; slice thickness, table feed and reconstruction index 5 mm each; scan-delay 30 s; 120 kV; 250 mAs) were evaluated for the detection, localization, and resectability of focal liver lesions by three experienced radiologists in consensus and were correlated with histopathological and intraoperative findings where available (59/168). Results: The sensitivity of SCTAP for the detection of liver tumors was 91% for all lesions and 84% for lesions [de

  18. Evaluation of Current Computer Models Applied in the DOE Complex for SAR Analysis of Radiological Dispersion & Consequences

    Energy Technology Data Exchange (ETDEWEB)

    O' Kula, K. R. [Savannah River Site (SRS), Aiken, SC (United States); East, J. M. [Savannah River Site (SRS), Aiken, SC (United States); Weber, A. H. [Savannah River Site (SRS), Aiken, SC (United States); Savino, A. V. [Savannah River Site (SRS), Aiken, SC (United States); Mazzola, C. A. [Savannah River Site (SRS), Aiken, SC (United States)

    2003-01-01

    The evaluation of atmospheric dispersion/ radiological dose analysis codes included fifteen models identified in authorization basis safety analysis at DOE facilities, or from regulatory and research agencies where past or current work warranted inclusion of a computer model. All computer codes examined were reviewed using general and specific evaluation criteria developed by the Working Group. The criteria were based on DOE Orders and other regulatory standards and guidance for performing bounding and conservative dose calculations. Included were three categories of criteria: (1) Software Quality/User Interface; (2) Technical Model Adequacy; and (3) Application/Source Term Environment. A consensus-based limited quantitative ranking process was used to base an order of model preference as both an overall conclusion, and under specific conditions.

  19. Qualitative evaluation of environmental radiological impact in a phosphate associated uranium conventional mine: Santa Quiteria Project, CE, Brazil

    International Nuclear Information System (INIS)

    Reis, Rocio G. dos; Santo, Aline Sa E.

    2013-01-01

    The aim of this study is to identify and evaluate qualitatively the main potential sources of mineral and installation terms of Santa Quiteria, CE, Brazil, evaluating their possible impacts on the environment. The key terms sources in the production of phosphoric acid are usually: the dig of the mines, tailings dams and phospho plaster stack. Thus, this work intends to inform the academic community about this issue, as well as the population in general and also, acting proactively in order to warn about the possible environmental impacts, so that actions to compensate, minimize or avoid these radiological impacts on the environment, can be included in the planning of the industrial mineral project of Santa Quiteria (author)

  20. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453; Avaliacao das condicoes e das praticas de protecao radiologica dos tecnicos em radiologia, segundo a portaria 453

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rogerio Ferreira da

    2013-10-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  1. Predicting the number and sizes of IBD regions among family members and evaluating the family size requirement for linkage studies.

    Science.gov (United States)

    Yang, Wanling; Wang, Zhanyong; Wang, Lusheng; Sham, Pak-Chung; Huang, Peng; Lau, Yu Lung

    2008-12-01

    With genotyping of high-density single nucleotide polymorphisms (SNPs) replacing that of microsatellite markers in linkage studies, it becomes possible to accurately determine the genomic regions shared identity by descent (IBD) by family members. In addition to evaluating the likelihood of linkage for a region with the underlining disease (the LOD score approach), an appropriate question to ask is what would be the expected number and sizes of IBD regions among the affecteds, as there could be more than one region reaching the maximum achievable LOD score for a given family. Here, we introduce a computer program to allow the prediction of the total number of IBD regions among family members and their sizes. Reversely, it can be used to predict the portion of the genome that can be excluded from consideration according to the family size and user-defined inheritance mode and penetrance. Such information has implications on the feasibility of conducting linkage analysis on a given family of certain size and structure or on a few small families when interfamily homogeneity can be assumed. It can also help determine the most relevant members to be genotyped for such a study. Simulation results showed that the IBD regions containing true mutations are usually larger than regions IBD due to random chance. We have made use of this feature in our program to allow evaluation of the identified IBD regions based on Bayesian probability calculation and simulation results.

  2. Bone paracoccidioidomycosis associated with acquired immunodeficiency syndrome: evaluation by radiological methods - a case report

    International Nuclear Information System (INIS)

    Maeda, Lucimara; Hara, Monica Hiromi; Sabedotti, Ismail Fernando; Montandon, Cristiano; Torriani, Martin; Nanni, Livio

    1999-01-01

    Paracoccidioidomycosis is a chronic granulomatous disease, caused by the Paracoccidioides brasiliensis fungus. This disease involves primarily the lungs, although disseminated forms may occur. Bone involvement is rare, and is associated to systemic disease or may present as a focal lesion. An association between paracoccidioidomycosis and the acquired immunodeficiency syndrome (AIDS) was first established in 1989. There are only a few reports on this association, and none of them was the fungus isolated from bone lesions. This is the first case report on the paracoccidioidomycosis-AIDS association in which bone lesions demonstrated infection by P. brasiliensis. The authors propose the inclusion of paracoccidioidomycosis in the differential diagnosis of lytic bone lesions in patients with AIDS and discuss the role of radiological diagnostic in this case. (author)

  3. Radiological impact evaluation on the aquatic ecosystems surrounding IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Jacomino, Vanusa F.; Maduar, Marcelo F.; Bellintani, Sandra A.; Mazzilli, Barbara P.

    1996-01-01

    In order to control the discharge of radioactive materials into the aquatic system surrounding IPEN-CNEN/SP, an monitoring program has been carried out on a routine basis. All the liquid effluent generated by the IPEN facilities are released into the Pinheiros river at two different discharge points located 2 km apart. In the present paper the source term measured during the period 1985 to 1984 is presented, as well as the effective equivalent dose received by public individuals for each critical pathway. These results showed that the total activity released into the Pinheiros river is just a small fraction of the receiving capacity of the environment. The estimated annual doses during the period of study were always below 1/10 of the primary limit for the public individual as established by the International Commission of Radiological Protection, which is 1 mSv/year. (author)

  4. EVALUATING ROBOT TECHNOLOGIES AS TOOLS TO EXPLORE RADIOLOGICAL AND OTHER HAZARDOUS ENVIRONMENTS

    International Nuclear Information System (INIS)

    Curtis W. Nielsen; David I. Gertman; David J. Bruemmer; R. Scott Hartley; Miles C. Walton

    2008-01-01

    There is a general consensus that robots could be beneficial in performing tasks within hazardous radiological environments. Most control of robots in hazardous environments involves master-slave or teleoperation relationships between the human and the robot. While teleoperation-based solutions keep humans out of harms way, they also change the training requirements to accomplish a task. In this paper we present a research methodology that allowed scientists at Idaho National Laboratory to identify, develop, and prove a semi-autonomous robot solution for search and characterization tasks within a hazardous environment. Two experiments are summarized that validated the use of semi-autonomy and show that robot autonomy can help mitigate some of the performance differences between operators who have different levels of robot experience, and can improve performance over teleoperated systems

  5. Evaluation of radiological safety assessment of a repository in a clay rock formation

    International Nuclear Information System (INIS)

    1999-01-01

    This report presents a comprehensive description of the post-closure radiological safety assessment of a repository for the spent fuel arisings resulting from the Spanish nuclear program excavated in a clay host rock formation. In this report three scenarios have been analysed in detail. The first scenario represents the normal in detail. The first scenario represents the normal evolution of the repository (Reference Scenario); and includes a set of variants to investigate the relative importance of the various repository components and examine the sensitivity of the performance to parameters variations. Two altered scenarios have also been considered: deep well construction and poor sealing of the repository. This document contains a detailed description of the repository system, the methodology adopted for the scenarios generation, the process modelling approach and the results of the consequences analysis. (Author)

  6. Clinical and radiological evaluation of hybrid hip replacement in various disorders of hip

    Directory of Open Access Journals (Sweden)

    Dhaon B

    2005-01-01

    Full Text Available Background: High rates of loosening of cemented implants led to change in technique of fixation of the implant. Methods: Fifty-nine hips were operated in 42 patients with non-cemented acetabular and cemented femoral components between January 1999 and July 2003. The average age of the patient was 45.2 years in our study. Preoperative diagnosis was avascular necrosis (28, ankylosing spondylitis (18, fracture neck femur (9, rheumatoid arthritis (2 and osteoarthritis (2. Results: At an average follow up of 3.6 years (range 1.2-5.8 years excellent to good results were obtained 92% according to Harris hip criteria. No radiological loosening was noted in any femoral or acetabular component on follow up. One poor result was seen in a case of bilateral ankylosing spondylitis operated on one side. Conclusion: Hybrid THA provides a viable and highly acceptable method of treatment of diseases of hip in young patients.

  7. Transcrestal Sinus Lift Procedure Approaching Atrophic Maxillary Ridge: A 60-Month Clinical and Radiological Follow-Up Evaluation

    Directory of Open Access Journals (Sweden)

    G. Lo Giudice

    2015-01-01

    Full Text Available Aim. The aim of this study was to assess the success and the survival rate of dental implants placed in augmented bone after sinus lifting procedures. Material and Methods. 31 patients were mainly enrolled for a residual upper jaw crest thickness of 3 mm. CBCT scans were performed before and after the augmentation technique and at the follow-up appointments, at 3, 6, 12, 24, and up to 60 months. The follow-up examination included cumulative survival rate of implants, peri-implant marginal bone loss, and the height of sinus floor augmentation. Results. This retrospective study on 31 patients and 45 implants later inserted in a less than 3 mm crest showed excellent survival rates (99.5%, one implant was lost before loading due to an acute infection after 24 days, and two implants did not osteointegrate and were removed after 3 months. The radiological evaluation showed an average bone loss of 0.25 mm (±0.78 mm at the first follow-up appointment (3 months up to 0.30 mm (±1.28 mm after 60-month follow-up. Conclusion. In this study it was reported how even in less than 3 mm thick crest a transcrestal technique can predictably be used with a long-term clinical and radiological outcome, giving patients excellent stability of the grafted material and healthy clinical results.

  8. Radiology illustrated. Pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-One (ed.) [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiology

    2014-11-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  9. Evaluation of environmental change and its effects on the radiological performance of a hypothetical shallow engineered disposal facility at Elstow, Bedfordshire

    International Nuclear Information System (INIS)

    1988-03-01

    The results of a project designed to evaluate aspects of a hypothetical facility for disposal of radioactive wastes at Elstow, Bedfordshire, are described. The project included modelling of environmental change using the TIME2 code, groundwater flow modelling, biosphere modelling and risk analysis using the SYVAC A/C code. The aims of the work were to demonstrate use of TIME2, investigate the evolution of the facility's environment and to evaluate the influence of environmental change on estimates of radiological risk. Risk analysis of several time-independent environmental system states, using data obtained from the other tasks, indicated that environmental changes significantly influence estimates of radiological risk. (author)

  10. Real time Monte Carlo simulation for evaluation of patient doses involved in radiological examinations

    International Nuclear Information System (INIS)

    Fulea, D.; Cosma, C.

    2006-01-01

    In order to apply the Monte Carlo simulation technique for usual radiological examinations we developed a Pc program, 'IradMed', written entirely in Java. The main purpose of this program is to compute the organ doses and the effective dose of patients, which are exposed at a X-ray beam having photon energies in 10 to 150 keV radiodiagnostic range. Three major radiological procedures are considered, namely mammography, radiography and CT. The fluoroscopy implies an irregular geometry and therefore it is neglected. Nevertheless, a gross estimation of patient doses can be made taking into account the fluoroscopy as being composed of several radiographic examinations applied in different anatomical regions. The interactions between radiation and matter are well-known, and the accuracy of the calculation is limited by the accuracy of the anatomical model used to describe actual patients and by characterisation of the radiation field applied. In this version of IradMed, it is assumed that the absorbed dose is equal with kerma for all tissues. No procedure has been used to take account of the finite range of the secondary electrons that are produced by photoelectric or Compton interactions. These ranges are small compared with the dimensions of the organs, and the absorbed dose will not change abruptly with distance except at boundary where composition and density change. However these boundary effects would have little effect in the determination of the average doses to almost all organs, except the active bone marrow which is treated separately. Another justification for this kerma approximation is the fact that the sum of all electron energies that exit the organ is statistically equal with the sum of all electron energies that enter in that particular organ. In this version of program, it is considered the following interactions: the Rayleigh scattering, the Compton scattering and the photoelectric effect. The Compton scattering is modeled by several methods which

  11. Real time Monte Carlo simulation for evaluation of patient doses involved in radiological examinations

    Energy Technology Data Exchange (ETDEWEB)

    Fulea, D [Institute of Public Health ' Prof.Dr.Iuliu Moldovan' , Cluj-Napoca (Romania); Cosma, C [Babes-Bolyai Univ., Faculty of Physics, Cluj-Napoca (Romania)

    2006-07-01

    In order to apply the Monte Carlo simulation technique for usual radiological examinations we developed a Pc program, 'IradMed', written entirely in Java. The main purpose of this program is to compute the organ doses and the effective dose of patients, which are exposed at a X-ray beam having photon energies in 10 to 150 keV radiodiagnostic range. Three major radiological procedures are considered, namely mammography, radiography and CT. The fluoroscopy implies an irregular geometry and therefore it is neglected. Nevertheless, a gross estimation of patient doses can be made taking into account the fluoroscopy as being composed of several radiographic examinations applied in different anatomical regions. The interactions between radiation and matter are well-known, and the accuracy of the calculation is limited by the accuracy of the anatomical model used to describe actual patients and by characterisation of the radiation field applied. In this version of IradMed, it is assumed that the absorbed dose is equal with kerma for all tissues. No procedure has been used to take account of the finite range of the secondary electrons that are produced by photoelectric or Compton interactions. These ranges are small compared with the dimensions of the organs, and the absorbed dose will not change abruptly with distance except at boundary where composition and density change. However these boundary effects would have little effect in the determination of the average doses to almost all organs, except the active bone marrow which is treated separately. Another justification for this kerma approximation is the fact that the sum of all electron energies that exit the organ is statistically equal with the sum of all electron energies that enter in that particular organ. In this version of program, it is considered the following interactions: the Rayleigh scattering, the Compton scattering and the photoelectric effect. The Compton scattering is modeled by several methods which

  12. Real time Monte Carlo simulation for evaluation of patient doses involved in radiological examinations

    Energy Technology Data Exchange (ETDEWEB)

    Fulea, D. [Institute of Public Health ' Prof.Dr.Iuliu Moldovan' , Cluj-Napoca (Romania); Cosma, C. [Babes-Bolyai Univ., Faculty of Physics, Cluj-Napoca (Romania)

    2006-07-01

    In order to apply the Monte Carlo simulation technique for usual radiological examinations we developed a Pc program, 'IradMed', written entirely in Java. The main purpose of this program is to compute the organ doses and the effective dose of patients, which are exposed at a X-ray beam having photon energies in 10 to 150 keV radiodiagnostic range. Three major radiological procedures are considered, namely mammography, radiography and CT. The fluoroscopy implies an irregular geometry and therefore it is neglected. Nevertheless, a gross estimation of patient doses can be made taking into account the fluoroscopy as being composed of several radiographic examinations applied in different anatomical regions. The interactions between radiation and matter are well-known, and the accuracy of the calculation is limited by the accuracy of the anatomical model used to describe actual patients and by characterisation of the radiation field applied. In this version of IradMed, it is assumed that the absorbed dose is equal with kerma for all tissues. No procedure has been used to take account of the finite range of the secondary electrons that are produced by photoelectric or Compton interactions. These ranges are small compared with the dimensions of the organs, and the absorbed dose will not change abruptly with distance except at boundary where composition and density change. However these boundary effects would have little effect in the determination of the average doses to almost all organs, except the active bone marrow which is treated separately. Another justification for this kerma approximation is the fact that the sum of all electron energies that exit the organ is statistically equal with the sum of all electron energies that enter in that particular organ. In this version of program, it is considered the following interactions: the Rayleigh scattering, the Compton scattering and the photoelectric effect. The Compton scattering is modeled by several

  13. Competency-Based Teaching in Radiology - Implementation and Evaluation of Interactive Workstation-Based Learning to Apply NKLM-Based Content.

    Science.gov (United States)

    Koestner, Wolfgang; Otten, Wiebke; Kaireit, Till; Wacker, Frank K; Dettmer, Sabine

    2017-11-01

    Purpose  New teaching formats are required to implement competency-based teaching in radiology teaching. Therefore, we have established and evaluated two practical competency-based radiological courses. Materials and Methods  The courses were held in a multimedia room with 25 computers and a professional DICOM viewer. Students were taught basic image analysis and presented clinical cases with a DICOM viewer under supervision of an instructor using desktop monitoring software. Two courses (elective course and obligatory course) were evaluated by the students (n = 160 and n = 100) and instructors (n = 9) using an anonymized online survey. Results  Courses were evaluated positively by the students and instructors. From the perspective of the students, the courses increased understanding of cross-sectional anatomy (elective/obligatory course: 97 %/95 %) and radiologic findings (97 %/99 %). Furthermore, the course increased the students' interest in radiology (61 %/65 %). The students considered this way of teaching to be relevant to their future occupation (92 % of students in the obligatory course). The higher incidence of teacher-student interaction and the possibility of independent image analysis were rated positively. The majority of instructors did not observe increased distractibility due to the computers (67 %) or notice worse preparation for MC tests (56 %). However, 56 % of instructors reported greater preparation effort. Conclusion  Practical competency-based radiological teaching using a DICOM viewer is a feasible innovative approach with high acceptance among students and instructors. It fosters competency-based learning as proposed by the model curriculum of the German Radiological Society (DRG) and the National Competency-based Catalogue of Learning Objectives for Undergraduate Medical Education (NKLM). Key Points   · Practical competency-based radiological teaching is highly accepted by students and instructors

  14. Critical evaluation of safety and radiological protection requirements adopted for the transport of uranium and thorium ores and concentrates

    International Nuclear Information System (INIS)

    Mezrahi, Arnaldo; Crispim, Verginia R.

    2009-01-01

    This work evaluates in a critical way the safety and radiological protection recommendations established by the International Atomic Energy Agency - IAEA and adopted national and internationally, for the transport of uranium and thorium ores and concentrates, known according the transport regulations, as being of the Low Specific Activity Material Type-I, LSA-I, basing on more realistic scenarios than the presently existent, aiming at the determination of maximum exposure levels of radiation as well as the maximal contents of those materials in packages and conveyance. A general overview taking into account the scenarios foreseen by the regulations of the IAEA pointed out for a need of a better justification of the requirements edited by the Agency or should be used to support a request of revision of those regulations, national and internationally adopted, in the pertinent aspects to the transport of uranium and thorium ores and concentrates. (author)

  15. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  16. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  17. Evaluation of the radiological impact in the aquatic system in the surrounding of IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Jacomino, V.M.F.; Gordon, A.M.P.L.; Venturini, L.

    1989-12-01

    In order to control the discharges of radioactive material in the aquatic system (Jaguare stream and Pinheiros river) in the vicinity of IPEN-CNEN/SP an effluent monitoring program was established on a routine basis. This control is carried out by measuring the activity of the radionuclides present in the liquid effluents (source term) using gamma spectrometry and/or spectrophotometry. The results obtained are then compared with the discharge limits adopted by CNEN when a decision is made upon the discharge of the effluent under consideration. In 1988 the total activity discharged by the nuclear installations available was 1997, 9x10 6 Bq in a total volume of 2421,4 m 3 . The next step was to evaluate the effective equivalent dose in the general public by using the results of the source term and the information available concerning the environment. It was assumed that the only critical pathway is the external gamma irradiation of the people that work in the nearby of the discharge points in Pinheiros river. The effective equivalent dose obtained was 39,4η Sv and the most relevant radionuclides that should be considered 60 Co, 137 Cs, 131 I and 226 Ra. This result is less than 1/10 of the maximum admissible dose limit adopted by the Radiological Protection Standards which is 10 -3 Sv/year. In order to measure the level of radioactivity in the environment, samples of ground water, water and sediments of Pinheiros river were collected and analyzed by using gamma spectrometry and fluorimetry. The radionuclides found were 226 Ra, 22228 Ra, U Nat, 40 K and 7 Be with activities corresponding to the background levels. The analysis of these results and the evaluation of the equivalent dose show that the radiological impact in the aquatic systems considered is insignificant. (author) [pt

  18. Evaluation of design flood estimates with respect to sample size

    Science.gov (United States)

    Kobierska, Florian; Engeland, Kolbjorn

    2016-04-01

    Estimation of design floods forms the basis for hazard management related to flood risk and is a legal obligation when building infrastructure such as dams, bridges and roads close to water bodies. Flood inundation maps used for land use planning are also produced based on design flood estimates. In Norway, the current guidelines for design flood estimates give recommendations on which data, probability distribution, and method to use dependent on length of the local record. If less than 30 years of local data is available, an index flood approach is recommended where the local observations are used for estimating the index flood and regional data are used for estimating the growth curve. For 30-50 years of data, a 2 parameter distribution is recommended, and for more than 50 years of data, a 3 parameter distribution should be used. Many countries have national guidelines for flood frequency estimation, and recommended distributions include the log Pearson II, generalized logistic and generalized extreme value distributions. For estimating distribution parameters, ordinary and linear moments, maximum likelihood and Bayesian methods are used. The aim of this study is to r-evaluate the guidelines for local flood frequency estimation. In particular, we wanted to answer the following questions: (i) Which distribution gives the best fit to the data? (ii) Which estimation method provides the best fit to the data? (iii) Does the answer to (i) and (ii) depend on local data availability? To answer these questions we set up a test bench for local flood frequency analysis using data based cross-validation methods. The criteria were based on indices describing stability and reliability of design flood estimates. Stability is used as a criterion since design flood estimates should not excessively depend on the data sample. The reliability indices describe to which degree design flood predictions can be trusted.

  19. A radiologic analysis and comparative evaluation of hysterosalpingographic and laparoscopic findings in infertile patients

    International Nuclear Information System (INIS)

    Lee, Hang Young; Kim, Soo Won; Chung, Hye Kyung; Yu, Yun Jeong

    1984-01-01

    Hystreosalpingogram of 375 patients with infertility were reviewed with reference to radiological feature of each pathology and a comparative study of hysterosalpingography and laparoscopy in 36 patients was presented. This results were as follows;1. In 375 cases of infertility, 191 cases (50.9%) were primary infertility and 181 cases (49.1%) were secondary infertility. 2. The peak age distribution was 26 to 30 year old group in 211 cases (56.3%), and the peak duration of infertility was less than 3 years in 256 cases (68.3%). 3. Abnormal uterine findings were 115 cases (30.7%) and there were 73 cases of filling defects, 13 cases of irregularity, 12 cases of uterine flexion, 11 cases of congenital anomaly, and 9 cases of hypoplasia among them. 4. Abnormal tubal findings were 196 cases (52.3%) and there were 103 cases of simple obstruction, 69 cases of hydrosalpinx, and 50 cases of peritubal adhesion among them. 5. Intravasation of contrast media was noted in 42 cases (11.2%). 6. In 36 cases of laparoscopy, 23 cases (63.7%) was agreed to hysterosalpingography. 7. Although laparoscopy was better than hysterosalpingography in external anatomy of salpinx and relationship to ovary, hysterosalpingography should be important for fundamental study of infertile women because of lower failure rate, lower risk of complications, therapeutic effect, and lower cost.

  20. Finding a criterion for site evaluation by weighting radiological, meteorological and demographic data

    International Nuclear Information System (INIS)

    Doury, A.; Gerard, R.

    1975-01-01

    The general problem of compatibility between given installations and their site, as well as more specific problems such as those associated with decisions to be taken in regard to demographic equilibrium in the environment, logically involve finding quantitative or at any rate semiquantitative criteria that will enable selection to be made under the least subjective conditions possible. Since the air is frequently the principal primary vector of effluents, especially in the case of an accident, atmospheric discharges are considered first separately. As the task is to find a ''site security index'' integrating the meteorological and demographic data with radiological data relating to the potential sources and the consequences of contamination, the authors first consider the possibility of using the man.rem concept, which has the advantage of possessing the dimension of a collective dose. In view of the objections that have been raised, particularly in connection with the controversy over the existence of a threshold for the dose-equivalent effect relation, a number of other practices are described and discussed. The conclusions are complex and subject to revision. Several definitions of site security indices can be identified and, pending the final decision stage, actually put into use, in conjunction with specific maps or graphs serving to reveal potentially important features which might be obscured by excessive integrations or summations

  1. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  2. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  3. Axillary local anesthetic spread after the thoracic interfacial ultrasound block – a cadaveric and radiological evaluation

    Directory of Open Access Journals (Sweden)

    Patricia Alfaro de la Torre

    2017-11-01

    Full Text Available Background: Oral opioid analgesics have been used for management of peri- and postoperative analgesia in patients undergoing axillary dissection. The axillary region is a difficult zone to block and does not have a specific regional anesthesia technique published that offers its adequate blockade. Methods: After institutional review board approval, anatomic and radiological studies were conducted to determine the deposition and spread of methylene blue and local anesthetic injected respectively into the axilla via the thoracic inter-fascial plane. Magnetic Resonance Imaging studies were then conducted in 15 of 34 patients scheduled for unilateral breast surgery that entailed any of the following: axillary clearance, sentinel node biopsy, axillary node biopsy, or supernumerary breasts, to ascertain the deposition and time course of spread of solution within the thoracic interfascial plane in vivo. Results: Radiological and cadaveric studies showed that the injection of local anesthetic and methylene blue via the thoracic inter-fascial plane, using ultrasound guide technique, results in reliable deposition into the axilla. In patients, the injection of the local anesthetic produced a reliable axillary sensory block. This finding was supported by Magnetic Resonance Imaging studies that showed hyper-intense signals in the axillary region. Conclusions: These findings define the anatomic characteristics of the thoracic interfascial plane nerve block in the axillary region, and underline the clinical potential of this novel nerve block. Resumo: Justificativa: Os analgésicos orais à base de opioides têm sido usados para o manejo da analgesia nos períodos peri e pós-operatório de pacientes submetidos à linfadenectomia axilar. A região axilar é uma zona difícil de bloquear e não há registro de uma técnica de anestesia regional específica que ofereça o seu bloqueio adequado. Métodos: Após a aprovação do Conselho de Ética institucional

  4. Development of an integrated system for evaluation of environmental radiologic impact during emergency situations

    International Nuclear Information System (INIS)

    Conti, Luiz Fernando de Carvalho

    2002-03-01

    An integrated system for performing environmental dose assessment after nuclear or radiological emergencies has been developed, as a tool for decision making process. The system includes databases such as those describing radionuclide decay, dose conversion factors for several environmental geometries and radionuclides with emitted radiation and energies. It includes several models for predicting environmental behaviour at the short,medium and long terms, for both rural and urban environments and is flexible enough for simulating the exposure of members of the public due to small accidents involving individual sources up to large scale nuclear accidents with complex source terms to the environment. The model has been built in a way that can perform assessment of actual exposures or make forecasts for future exposure based on dynamic simulation of the fate of radionuclides in environmental and potential exposure pathways to members of the public, taking into account he kind of contaminated environment and the age groups of exposed persons. Input data may come from a predicted source term or information on environmental concentration based on dispersion models or on environmental measurements, including on line monitoring systems, environmental surveys, direct measurements by in situ gamma spectrometry or analysis of environmental samples. Outputs of the model are dose estimates to members of the public as a function of the exposure pathway, time after the contamination and age group, for different groups of members of the public and kind of use of the environment. Time dependent kerma rates in air and concentrations in environmental compartments such as soil and foodstuff are also available, including the simulation of the effect of protective measures, to support the decision making process. (author)

  5. Small, medium, large or supersize? The development and evaluation of interventions targeted at portion size

    Science.gov (United States)

    Vermeer, W M; Steenhuis, I H M; Poelman, M P

    2014-01-01

    In the past decades, portion sizes of high-caloric foods and drinks have increased and can be considered an important environmental obesogenic factor. This paper describes a research project in which the feasibility and effectiveness of environmental interventions targeted at portion size was evaluated. The studies that we conducted revealed that portion size labeling, offering a larger variety of portion sizes, and proportional pricing (that is, a comparable price per unit regardless of the size) were considered feasible to implement according to both consumers and point-of-purchase representatives. Studies into the effectiveness of these interventions demonstrated that the impact of portion size labeling on the (intended) consumption of soft drinks was, at most, modest. Furthermore, the introduction of smaller portion sizes of hot meals in worksite cafeterias in addition to the existing size stimulated a moderate number of consumers to replace their large meals by a small meal. Elaborating on these findings, we advocate further research into communication and marketing strategies related to portion size interventions; the development of environmental portion size interventions as well as educational interventions that improve people's ability to deal with a ‘super-sized' environment; the implementation of regulation with respect to portion size labeling, and the use of nudges to stimulate consumers to select healthier portion sizes. PMID:25033959

  6. Computers in radiology. The sedation, analgesia, and contrast media computerized simulator: a new approach to train and evaluate radiologists' responses to critical incidents

    International Nuclear Information System (INIS)

    Medina, L.S.; Racadio, J.M.; Schwid, H.A.

    2000-01-01

    Background. Awareness and preparedness to handle sedation, analgesia, and contrast-media complications are key in the daily radiology practice. Objective. The purpose is to create a computerized simulator (PC-Windows-based) that uses a graphical interface to reproduce critical incidents in pediatric and adult patients undergoing a wide spectrum of radiologic sedation, analgesia and contrast media complications. Materials and methods. The computerized simulator has a comprehensive set of physiologic and pharmacologic models that predict patient response to management of sedation, analgesia, and contrast-media complications. Photorealistic images, real-time monitors, and mouse-driven information demonstrate in a virtual-reality fashion the behavior of the patient in crisis. Results. Thirteen pediatric and adult radiology scenarios are illustrated encompassing areas such as pediatric radiology, neuroradiology, interventional radiology, and body imaging. The multiple case scenarios evaluate randomly the diagnostic and management performance of the radiologist in critical incidents such as oversedation, anaphylaxis, aspiration, airway obstruction, apnea, agitation, bronchospasm, hypotension, hypertension, cardiac arrest, bradycardia, tachycardia, and myocardial ischemia. The user must control the airway, breathing and circulation, and administer medications in a timely manner to save the simulated patient. On-line help is available in the program to suggest diagnostic and treatment steps to save the patient, and provide information about the medications. A printout of the case management can be obtained for evaluation or educational purposes. Conclusion. The interactive computerized simulator is a new approach to train and evaluate radiologists' responses to critical incidents encountered during radiologic sedation, analgesia, and contrast-media administration. (orig.)

  7. Territorial characterisation considering geo morphological properties of subsoil as well as climatic and meteorological conditions for the evaluation of the effects of radiological nature on the environment

    International Nuclear Information System (INIS)

    Malvicini, A.; Esposito, P.

    2002-01-01

    The composition and origin of the rocky substratum, the permeability of the ground, its degree of humidity and the particle size are the main factors that influence radon concentration in the subsoil and in the water stratums as well as its upward migration. The climatic and meteorological conditions, particularly the moisture, the barometric pressure and the temperature, can influence more or less directly the underground emanation and diffusion properties of radon and thoron giving rise to short-term modifications of radiological nature in the subsoil, closely related to the presence of these elements. The great concentration of some radioisotopes, in some particular areas, can also induce high dose rates caused by the radiation coming from emergent rocks, due for instance to activities related to building works, with consequent possible exposure of the personnel involved in underground excavations. In such situations it is possible to carry out systematical radiometric measurements, which provide instantaneous and time integrated data, using fixed or movable instrumentation. The stratigraphical structure of the subsoil and the related variations of lithological nature as well as the lack of homogeneity in the land, due also to the unevenness of the ground outline and to the presence of fault planes, increase considerably the complexity of analytical evaluations based upon the chemical and physical characteristics of the subsoil and upon the meteorological and climatic properties

  8. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  9. Computerized system to perform a general radiological evaluation of the persons that live in areas affected by the nuclear accident of Chernobyl

    International Nuclear Information System (INIS)

    Cruz Suarez, R.; Valdes, M.

    1993-01-01

    A computer program (EVACID) was developed with the purpose of performing a general radiological evaluation. EVACID system allows to automate an important group of dosimetric calculations, as well as to store, codify analyze and relate among them the medical information of the persons affected by the nuclear accident of Chernobyl

  10. The outcome of conservative treatment of adult distal radius fractures compared with the other wrist: radiological and functional evaluation

    Directory of Open Access Journals (Sweden)

    Mustafa Uslu

    2014-09-01

    Full Text Available Objective: This study was designed to evaluate anatomical and functional results of closed reduction-long arm cast treatment for distal radius fractures and compared other healthy wrist in the adults. Methods: 77 patients with distal radius fracture were treated conservatively between January 2010 and December 2010. The fractures were classified according to AO and Frykman classification system and investigated prospectively. The radiological and anatomical results were assessed by the Stewart score criteria. The functional results were assessed by Quick-Disability of Arm, Shoulder and Hand questionnaire (Q-DASH and the Stewart II score criteria. The mean follow-up of patients was 12 months. Results: The forty patients had right wrist fractured, 37 patients had left wrist fractured. According to Frykman classification 46 patients were type I-II fractured, according to AO classification 59 patients were type 23,A2,1 and 23,A2,2 fractured. According to Stewart the radiological and anatomical, the result were excellent in 57, good in 17, fair in 3. According to Stewart II functional criteria, the results were assessed excellent in 57, good in 8, fair in 12 The mean Q-DASH score was 6,37. The overall complication rate was 12.98%. Mild Carpal tunnel syndrome was observed in the two patients, ulna styloid nonunion in the four patients, pain of distal radioulnar joint in the one patient, mild carpal tunnel syndrome and tenderness of distal radioulnar joint in the three patients. Conclusion: Closed reduction and cast immobilization is still an effective and inexpensive treatment method in distal radial fractures. J Clin Exp Invest 2014; 5 (3: 403-409

  11. Radiation dose evaluation in patients submitted to conventional radiological examinations; Avaliacoes de doses de radiacao em pacientes submetidos a exames radiologicos convencionais

    Energy Technology Data Exchange (ETDEWEB)

    Tilly, Junior, Joao G

    1997-07-01

    This work presents the results of the evaluation of radiation dose delivered to the patients undergoing conventional radiological procedures. Based in the realized measurement some indicators are settled to quantitative appraisal of the radiological protection conditions offered to the population. Data assessment was done in the county of Curitiba, in Parana State, Brazil, from 12/95 to 04/96, in ten rooms of three different institutions, under 101 patients, adults with 70 {+-} 10 kg, during real examinations of chest PA, chest LAT and abdomen AP. (author)

  12. Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents.

    Science.gov (United States)

    Salerno, Sergio; Tudisca, Chiara; Murmura, Elena; Matranga, Domenica; La Tona, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio

    2017-05-01

    Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluated too. The number of correct characterizations was different due to the administration of the flow-chart. One hundred and six correct UVC assessments at the beginning switched to 196 after the administration of the flow-chart (p = 0.0001). The observed agreement among the twenty radiology residents was statistically significant, both before (kappa = 0.41, p < 0.001) and after (kappa = 0.37, p < 0.001) the flow-chart administration. The developed flow-chart demonstrated to be useful in increasing residents performance in UVC placement assessment.

  13. Evaluation of the radiological safety of the working area in the installation of experimental fuel elements in 2010

    International Nuclear Information System (INIS)

    Nudia Barenzani

    2011-01-01

    Evaluations of radiological safety in working areas in IEBE during 2010 have been conducted. The purpose of this evaluation was to determine that the working area in IEBE is safe for workers to conducting research and development of nuclear fuel. The evaluation is done by analyzing the results of routine monitoring in the laboratory of IEBE during the year 2010, such as gamma exposure, alpha radioactivity in air and surface contamination. The result is the highest gamma exposure (3.213 ± 0.121) µSv/h at the desk-work-B in HR-05, alpha Radioactivity in air at (4.980 ± 0.444) Bq/m 3 and the average surface contamination (0.090 ± 0.008) Bq/cm 2 . The result is still above Permissible Maximum Concentration (MPC) and in the Lower Dose Limit Value established by the Regulatory Body. So it can be concluded that IEBE laboratory is safe for workers in conducting research and development nuclear fuel. (author)

  14. Evaluation of the radiological quality of the water on Bikini and Eneu Islands in 1975: dose assessment based on initial sampling

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Robison, W.L.; Wong, K.M.; Eagle, R.J.

    1977-01-01

    This report describes the radiological quality of the groundwater on the two main islands (Eneu and Bikini) of Bikini Atoll during June 1975 (from data obtained from water samples collected at old and new well sites on both islands) and the cistern water on Bikini Island. Based on analyses of these samples, we found that the cistern water from Bikini Island is both chemically and radiologically acceptable as drinking water in accordance with standard limits established by the U.S. Public Health Service. However, on both islands the quality of the groundwater varied from one site to another. At some wells both chemical and radiological quality are acceptable; at others one or both are unacceptable according to U.S. Public Health Standards. The doses we predict from consumption of both cistern and groundwater are acceptable under federal guidelines. However, doses predicted from consumption of groundwater are high enough to warrant careful evaluation of other potential exposure pathways

  15. Evaluation of Radiology Teachers' Performance and Identification of the "Best Teachers" in a Residency Program: Mixed Methodology and Pilot Study of the MEDUC-RX32 Questionnaire.

    Science.gov (United States)

    Huete, Álvaro; Julio, Rodrigo; Rojas, Viviana; Herrera, Cristián; Padilla, Oslando; Solís, Nancy; Pizarro, Margarita; Etcheberry, Lorena; Sarfatis, Alberto; Pérez, Gonzalo; Díaz, Luis A; Delfino, Alejandro; Muñoz, Estrella; Rivera, Horacio; Parra, Dimitri A; Bitran, Marcela; Riquelme, Arnoldo

    2016-07-01

    Radiology teachers are well trained in their specialty; however, when working in academic institutions, faculty development and promotion through the education pathway tends to be based on their teaching knowledge and skills. The aim of this study is to assess psychometric properties of the Medicina Universidad Católica-Radiology 32 items (MEDUC-RX32), an instrument designed to evaluate the performance of postgraduate radiology teachers and to identify the best teachers. Mixed methodology was used, including qualitative and quantitative phases. The psychometric properties of the MEDUC-RX32 survey were performed by factor analysis (validity), Cronbach alpha coefficient, and G coefficient (reliability). The residents assessed their teachers and simultaneously voted for the "best teacher," which was used as a gold standard for the receiver operating characteristic curves construction comparing their votes with the global score. A total of 28 residents answered 164 surveys. The global score was 6.23 ± 0.8 (scale from 1 to 7). The factor analysis showed six domains of the resident's perception: (1) tutorial teaching, feedback, and independent learning; (2) communication and teamwork; (3) learning objectives; (4) respectful behavior; (5) radiological report; and (6) teaching and care support. The tutor's strengths were related with respectful behavior and teamwork. The instrument is highly reliable with a Cronbach alpha of 0.937 and a G coefficient of 0.831 (with a minimum of 8 residents). The MEDUC-RX32 instrument has a sensitivity of 91.7% and specificity of 83.3% to identify tutors as best teachers with at least one vote with an area under the receiver operating characteristic curve of 0.931 with a cutoff of 5.94. The MEDC-RX32 instrument is a multidimensional, valid, and highly reliable method to evaluate radiology teachers, identifying teachers with excellence in tutorial teaching in a postgraduate radiology program. Copyright © 2016 The Association of

  16. The characteristics of radiological cloud caused by 'dirty bomb' attack

    International Nuclear Information System (INIS)

    Wang Qingbo; Wang Bairong

    2006-01-01

    This paper discusses the characteristics of the radiological cloud after the RDD explosion, including the initial cloud size, material's distribution and the rate of particle or aerosol sedimentation. For there are limited papers in involved this topic publicly, only empirical formulas are given. However, it would be helpful when evaluating the consequences of the RDD terrorism attacks. (authors)

  17. Size-selective performance evaluation of candidate aerosol inlets using polydisperse aerosols

    Data.gov (United States)

    U.S. Environmental Protection Agency — Presented are detailed techniques for the generation, collection, and analysis of polydisperse calibration aerosols for wind tunnel evaluation of size-selective...

  18. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  19. Psychological evaluation of the patients contaminated in the Goiania radiological accident in Brazil

    International Nuclear Information System (INIS)

    1989-08-01

    The psychological evaluation of 68 patients contaminated in the Goiania accident as well as of the personnel (about 27) working at the organizations responsible for the assistance given to the victims of the accident is presented

  20. Guidelines for selection of radiological protective head covering

    International Nuclear Information System (INIS)

    Galloway, G.R. Jr.

    1995-08-01

    The hood is recognized throughout the nuclear industry as the standard radiological protective head covering for use in radioactively contaminated work environments. As of June 15, 1995, hoods were required for all activities performed in contaminated areas at the Y-12 Plant. The use of hoods had historically been limited to those radiological activities with a high potential for personnel contamination. Due to the large size of many posted contaminated areas at the Y-12 Plant, and compounding safety factors, requirements for the use of hoods are being reevaluated. The purpose of the evaluation is to develop technically sound guidelines for the selection of hoods when prescribing radiological protective head covering. This report presents the guidelines for selection of radiological protective hoods

  1. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  2. Radiological evaluation of double-outlet right ventricle - An analysis of cinecardioangiography in 44 cases -

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Double-outlet right ventricle is defined as follows: both great arteries arise completely or nearly completely from the right ventricle; neither semilunar valve is in fibrous continuity with either atrioventricular valve; and usually a ventricular septal defect is present and the only outlet from the left ventricle. A total of 44 cases of double-outlet right ventricle is analyzed, in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 4 year and 6 months, with specific reference to the segmental combinations, the height of conus, the relationship of great arteries, the location of ventricular septal defects, and associated anomalies. The results were as follows; 1. Among 44 cases, 36 cases had normal cardiac position, 4 cases had dextrocardia with situs inversus 2 cases had dextrocardia with situs solitus, 1 case had levocardia with situs inversus, and another 1 case had mesocardia with situs ambiguus. 2. Segmental sets were [S,D,D] in 36 cases, [I,L,L] in 3 cases, [I,D,D] in 2 cases, [S,D,L], [S,L,L] and [A,D,D] in 1 case respectively. 3. All cases had bilateral conus. Aortic valve rings were same level as pulmonary valve rings in 25 cases, lower than pulmonary valve rings in 17 cases in which 15 cases were type A., and higher than pulmonary valve rings in 2 cases. 4. The relation of the great arteries were normal in 15 cases, side-by-side in 13 cases, dextromalposition in 13 cases, and levomal position in 3 cases. 5. The position of the ventricular septal defects with respect to the origins of the great arteries is subaortic (type A and type B) in 23 cases, subpulmonary (type C) in 13 cases, doubly committed (type D) in 3 cases, and uncommitted (type E) in 5 cases. 6. Associated cardiac malformations are pulmonary stenosis in 24 which had all cases of type A and type E, aortic stenosis in 6 which were only in type C, left SVC in 6, abnormality of atrioventricular valve in 5, single coronary artery

  3. Evaluation of instruments used in particle size analysis by using the sedimentation technique

    International Nuclear Information System (INIS)

    Elmasry, M.A.A.; Abdrahman, A.A.M.; Ahmed, A.Z.

    2007-01-01

    This study is carried out to evaluate the performance of some instruments in which the sedimentation technique is used for the determination of particle size distribution using Stoke's law. A mathematical formula has been developed to calculate the particle size distribution for different cases and the results were compared to the real ones. The results revealed unsatisfactory agreement between the calculated and the measured values. In addition, illogic results were obtained indicating that the instruments in which the sedimentation technique is used are not the proper ones to provide accurate measurements except for mono particle size cases. More above, the results obtained represent the sedimentation rate but not the particle size distribution.

  4. Evaluation research of small and medium-sized enterprise informatization on big data

    Science.gov (United States)

    Yang, Na

    2017-09-01

    Under the background of big data, key construction of small and medium-sized enterprise informationization level was needed, but information construction cost was large, while information cost of inputs can bring benefit to small and medium-sized enterprises. This paper established small and medium-sized enterprise informatization evaluation system from hardware and software security level, information organization level, information technology application and the profit level, and information ability level. The rough set theory was used to brief indexes, and then carry out evaluation by support vector machine (SVM) model. At last, examples were used to verify the theory in order to prove the effectiveness of the method.

  5. Evaluation of radiological service of Dental Clinic, Uberlandia Federal University (MG-Brazil)

    International Nuclear Information System (INIS)

    Vieira, C.D.V.T.

    1985-01-01

    The management related problems and the quality of dental radiographs of the Radiographic Service of the Dental Clinic, Uberlandia Federal University (MG-Brazil) are evaluated. The results are based on the examinations of 404 dental files from patients atending the Dental Clinic in 1983. Frequency distribution, mean and percentages were computed for the variables studied. (M.A.C.) [pt

  6. A combined pulmonary-radiology workshop for visual evaluation of COPD

    DEFF Research Database (Denmark)

    Barr, R Graham; Berkowitz, Eugene A; Bigazzi, Francesca

    2012-01-01

    The purposes of this study were: to describe chest CT findings in normal non-smoking controls and cigarette smokers with and without COPD; to compare the prevalence of CT abnormalities with severity of COPD; and to evaluate concordance between visual and quantitative chest CT (QCT) scoring....

  7. 76 FR 72431 - Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness...

    Science.gov (United States)

    2011-11-23

    ... national preparedness terms and concepts found in the National Incident Management System (NIMS)/ Incident... many of the REP Program's operative guidance and policy documents into one location, and [[Page 72432... for alert and notification systems. In addition, Supplement 4 revises and adds evaluation criteria and...

  8. X-ray absorbed doses evaluation on patients under radiological studies

    International Nuclear Information System (INIS)

    Medeiros, Regina Bitelli; Daros, Kellen A.C.

    1996-01-01

    The skin absorbed doses were evaluated on patient submitted to the following x-ray exams : chest, facial sinus, lumbar spine. Thermoluminescent dosimetry was used and a variety of irradiation techniques performed. The results shown considerable differences on the absorbed dose for the various alternative technical conditions

  9. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  10. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  11. Radiological hazards

    International Nuclear Information System (INIS)

    Hamilton, M.

    1984-01-01

    The work of the (United Kingdom) National Radiological Protection Board is discussed. The following topics are mentioned: relative contributions to genetically significant doses of radiation from various sources; radon gas in non-coal mines and in dwelling houses; effects of radiation accidents; radioactive waste disposal; radiological protection of the patient in medicine; microwaves, infrared radiation and cataracts; guidance notes for use with forthcoming Ionising Radiations Regulations; training courses; personal dosimetry service; work related to European Communities. (U.K.)

  12. Therapy evaluation and diagnostic accuracy in neuroendocrine tumours: assessment of radiological methods

    International Nuclear Information System (INIS)

    Elvin, A.

    1993-01-01

    The diagnostic accuracy of ultrasonically guided biopsy-gun biopsies was assessed in a group of 47 patients with suspected pancreatic carcinoma. A correct diagnosis was obtained in 44 of the 47 patients (94%). Biopsy-gun biopsy of the pancreas is considered a useful, reliable and non-traumatic method for the diagnosis of pancreatic malignancy. Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles. The influence of treatment-related fibrosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. In order to assess the diagnostic accuracy rate for radiologists with different experience of biopsy procedures 175 cases of renal biopsy-gun biopsies were evaluated. No statistical significant difference was found between the different operators. The role of duplex Doppler ultrasound in monitoring interferon treatment-related changes in carcinoid metastases was evaluated. It present duplex Doppler ultrasound does not seem to play a role in the evaluation of tumour therapy in carcinoid patients. Therapy response evaluation was performed with MR imaging in a group of 17 patients with neuroendocrine liver metastases. A significant difference was found between patients responding to and patients with failure of treatment in terms of tumour T1, contrast enhancement and signal intensity ratio. This indicates that MR investigation may be used in therapy monitoring of patients with neuroendocrine metastases. The neuroendocrine-differentiated colonic carcinoma cell line (LCC-18) was transplanted to 29 mice to establish a tumour/animal model that would allow the monitoring of changes with MR imaging induced by interferon therapy and to evaluate whether the therapeutic response could be modulated by different interferon dosages. Interferon does not seem to have any prolonged anti-proliferative effect on the LCC-18 tumour cell line when transplanted to

  13. Cough urethrocystography: The best radiological evaluation of female stress urinary incontinence?

    International Nuclear Information System (INIS)

    Varpula, M.; Maekinen, J.; Kiilholma, P.

    1989-01-01

    Urethrocystography and simultaneous urethrocystometry were performed on 40 women with primary urinary incontinence. The posterior urethrovesical angle, inclination angle, urethropelvic angle, and an orifice descent angle, not earlier described, were measured on radiographs obtained at rest, during coughing and during straining. The orifice descent angle was used to describe the descent of the internal urethral orifice in the cough radiographs, and was the only measurement that provided a significant correlation with urethrocystometry. The other angles measured, and radiographs obtained at rest or during straining were not useful in the evaluation of female stress urinary incontinence. The authors conclude that the best imaging method for the evaluation of female stress urinary incontinence is urethrocystography employing a single lateral view taken during coughing, with measurement of the orifice descent angle. (orig.)

  14. Scoliosis circa 2000: radiologic imaging perspective. Pt. 1. Diagnosis and pretreatment evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Oestreich, A.E. [Radiology Department, Children`s Hospital Medical Center, Cincinnati, OH (United States); Young, L.W. [Department of Pediatric Radiology, Loma Linda University Children`s Hospital, CA (United States); Young Poussaint, T. [Department of Radiology, Children`s Hospital, Boston, MA (United States)

    1998-11-01

    Plain film imaging remains important for the diagnosis and surveillance of scoliosis, as well as for the detection of complications after surgery. Advances in CT and MR imaging have greatly improved the ability to detect or confirming nonidiopathic causes of scoliosis, including abnormalities within the spinal canal. Three-dimensional thinking has become more important in evaluating and understanding scoliosis. (orig.) With 11 figs., 3 tabs., 75 refs.

  15. Evaluation of porous vitreous carbon or silicon implants by radiology in rat's skull

    International Nuclear Information System (INIS)

    Vaccari-Mazzetti, Marcelo Paulo; Kobata, Celio Toshiro; Fabiani, Paulo; Martins, Dulce Maria Fonseca Soares; Gomes, Paulo de Oliveira; Martins, Jose Luiz

    2008-01-01

    Purpose: Evaluate by CT the use of porous vitreous carbon (PVC) and silicon (S) implants as the replacement bone in the craniofacial skeleton of rats. Methods: 40 rats divided in: Group A (n=20) PVC submitted to the implant of a fragment in skull. After the euthanasia, the animals were divided into two subgroups: A I: 10 animals, studied in the 7th postoperative day (P.O) and AII: 10 animals, studied in the 28th P.O. In group B, S, 20 rats were submitted to S implant in the skull. All other steps were identical to group A, with designation of subgroups BI and BII. CT with beams in axial cuts of 1 mm thickness to obtain 3-D information It was used Hounsfield scale for evaluate the radio density of the implant. They were used non parametric tests to analyze the results. Results: The 7th PO boss remained in the two groups, but for 28th PO, observed reduction in the volume of the implant in Group A, not observed in group B. CT studies noticed different radio densities around all of S prostheses (pseudo capsule), that do not appeared in CPV implants. The S has remained unchanged in the CT, but the CPV has had a modification in its radio density (p≤0,05), in all implants. Conclusion: In CT evaluation the implants of CPV have greater deformation that the S, which makes them not suitable for replacement of membranous bone in the rat skull. (author)

  16. Evaluation of doses given to foetus in diagnostic radiology in Israel

    International Nuclear Information System (INIS)

    Schlesinger, T.; Donagi, A.; Karpinovitz, A.

    1975-01-01

    Among the various groups exposed to diagnostic radiation, pregnant women, during the first months of pregnancy, require special attention, because of the high sensitivity of the developing foetus to ionizing radiation. In light of this sensitivity, special limitations were adopted in different countries, concerning female X-ray technicians in the reproductive age. However, it frequently happens that a pregnant woman is irradiated during the first months of pregnancy, due to the fact that neither she nor the attending physician is aware that she is pregnant. Many times, after this fact is realized, physicists are asked to ''reconstruct'' the radiographs in order to evaluate the foetus dose. The purpose of this ''reconstruction'' is to determine whether an abortion is to be performed. The present work constitutes the first stage of a research desianed to provide the radiologist with typical Israeli data, which he could use for evaluating the order of magnitude of the foetus dose. The purpose of this ''preliminary evaluation'' carried out by the radiologist is to determine whether the foetus dose is of such a magnitude justifying the performance of a specific ''reconstruction test'' or not. (B.G.)

  17. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  18. Development and evaluation of Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in a Nuclear Medicine Service

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Universidade Federal do Rio de Janeiro (PEB/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Biomedica; Soares, Alexandre B. [Universidade Federal do Rio de Janeiro (IF/UFRJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Corbo, Rossana [Universidade Federal do Rio de Janeiro (FM/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia

    2011-07-01

    The quality management in Nuclear Medicine Services is a requirement of national and international standards. The Brazilian regulatory agency in health surveillance, the Agencia Nacional de Vigilancia Sanitaria (ANVISA), in its Resolucao de Diretoria Colegiada (Collegiate Directory Resolution) no. 38, requires the elaboration of documents describing the technical and clinical routine activities. This study aimed to elaborate, implement and evaluate Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in the Nuclear Medicine Service of a university hospital. Eighteen SOPs were developed, involving tasks related to dose calibrator, gamma camera, Geiger-Muller detectors and radiological protection activities. The performance of its application was evaluated for a period of six months. It was observed a reduction in 75% of reported operational errors and 42% of the number of reported incidents with contamination by radioactive material. The SOPs were adequate and successful in its application. New procedures involving clinical activities will also be developed and evaluated. (author)

  19. A radiologic evaluation of bladder tumors on barium air double contrast cystography and triple-fractionated cystography

    International Nuclear Information System (INIS)

    Hur, W. J.; Jang, H. Y.; Sol, C. H.; Kim, B. S.

    1984-01-01

    Clinically bladder tumors can be easily diagnosed on cystoscopic examination and biopsy in the patients with silent hematuria, terminal dribbling and dysuria. But for the evaluation of the extent of tumor invasion, the authors performed both barium-air double contrast and triple-fractionated cystography on 16 patients suspected to be bladder tumor on cystoscopic examination in the radiologic department of B.N.U.H. from September 1982 to August 1983. The obtained results were summarized as follows. 1. On barium-air double contrast cystography and triple-fractionated cystography, 13 cases were concluded as bladder tumor, and 3 cases were consistent with the findings of chronic inflammation out of the total 16 cases. 2. After operation of 15 cases, 12 cases were confirmed pathologically as transitional cell carcinoma, 1 case as prostatic hypertrophy, and 2 cases as chronic inflammation. Remaining one was biopsied on cystoscopic examination, and confirmed as chronic inflammation. 3. Among 9 cases of transitional cell carcinoma having the evidence of muscle invasion on triple- fractionated cystography, 8 cases were confirmed as more than stage B 1 on pathologic study, and the other as chronic inflammation. 4. In detecting multiplicity, presence of ulceration, and evaluation of nature of tumor surface, barium- air double contrast cystogrpahy was more excellent than cystoscopic results. 5. Cases presenting both ulceration and cauliflower appearance on barium- air double contrast cystography was more than grade III on microscopic evaluation. 6. In conclusion, the authors considers the barium-air double contrast and triple-fractionated cystography are easy to perform, reasonable in price and have relatively high accuracy in tumor detection, staging and grading.

  20. Radiological and clinical outcomes of novel Ti/PEEK combined spinal fusion cages: a systematic review and preclinical evaluation.

    Science.gov (United States)

    Assem, Yusuf; Mobbs, Ralph J; Pelletier, Matthew H; Phan, Kevin; Walsh, William R

    2017-03-01

    The primary objective of this paper was to provide a systematic review of the available clinical studies of Ti/PEEK combined cages in spinal interbody fusion surgeries, focusing on their radiological and clinical outcomes. A secondary aim was to provide a review and evaluation of the in vitro and preclinical studies reported on Ti/PEEK-coated implants. A systematic search of the literature was performed in March 2015 via three databases: Medline, Embase and Cochrane library. The following key search terms were combined with synonyms to identify relevant articles: "spinal fusion," "PEEK," "titanium" and "cage." The novelty of this intervention translates into a paucity of clinical trials, albeit the results of the seven clinical studies that met the criteria for inclusion are promising. All studies reported rate of fusion as a primary outcome. Two studies reported slightly improved fusion in the experimental Ti/PEEK combination cohort, one study identical fusion (91.7 %) and three studies excellent fusion (96, 100 and 94 %) in the Ti/PEEK cohort, although no differences reached statistical significance. Clinical studies at this early stage demonstrate that Ti/PEEK implants are safe and efficacious, exhibiting similar fusion rates and clinical outcomes compared to the current standard PEEK. There is clinical evidence substantiating the improved radiographic fusion of Ti/PEEK, albeit the differences were not significant. This field is promising, gaining substantial popularity, and further clinical trials are needed in the future to establish Ti/PEEK cages as a mainstay of clinical practice.

  1. Is radiological evaluation as good as computer-based volumetry to assess hippocampal atrophy in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Boutet, Claire; Drier, Aurelie; Dormont, Didier; Lehericy, Stephane; Chupin, Marie; Colliot, Olivier; Sarazin, Marie; Mutlu, Gurkan; Pellot, Audrey

    2012-01-01

    Hippocampus volumetry is a useful surrogate marker for the diagnosis of Alzheimer's disease (AD). Our purpose was to compare visual assessment of medial temporal lobe atrophy made by radiologists with automatic hippocampal volume and to compare their performances for the classification of AD, mild cognitive impairment (MCI) and cognitively normal (CN). We studied 30 CN, 30 MCI and 30 AD subjects. Six radiologists with two levels of expertise performed two readings of medial temporal lobe atrophy. Medial temporal lobe atrophy was evaluated on coronal three-dimensional T1-weighted images using Scheltens scale and compared with hippocampal volume obtained using a fully automatic segmentation method (Spearman's rank coefficient). Visual assessment of medial temporal lobe atrophy was correlated with hippocampal volume (p < 0.01). Classification performances between MCI converter and CN was better using volumetry than visual assessment of non-expert readers whereas classification of AD and CN did not differ between visual assessment and volumetry except for the first reading of one non-expert (p = 0.03). Visual assessment of medial temporal lobe atrophy by radiologists was well correlated with hippocampal volume. Radiological assessment is as good as computer-based volumetry for the classification of AD, MCI non-converter and CN and less good for the classification of MCI converter versus CN. Use of Scheltens scale for assessing hippocampal atrophy in AD seems thus justified in clinical routine. (orig.)

  2. Is radiological evaluation as good as computer-based volumetry to assess hippocampal atrophy in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Boutet, Claire; Drier, Aurelie; Dormont, Didier; Lehericy, Stephane [Groupe Hospitalier Pitie-Salpetriere, Department of Neuroradiology, AP-HP, Paris Cedex 13 (France); Universite Pierre et Marie Curie-Paris 6, Centre de Recherche de l' Institut du Cerveau et de la Moelle epiniere, UMR-S975, Paris (France); Inserm, Paris (France); CNRS, Paris (France); ICM-Institut du Cerveau et de la Moelle epiniere, Paris (France); Chupin, Marie; Colliot, Olivier [Universite Pierre et Marie Curie-Paris 6, Centre de Recherche de l' Institut du Cerveau et de la Moelle epiniere, UMR-S975, Paris (France); Inserm, Paris (France); CNRS, Paris (France); ICM-Institut du Cerveau et de la Moelle epiniere, Paris (France); Equipe Cogimage-CRICM, Paris Cedex 13 (France); Sarazin, Marie [Universite Pierre et Marie Curie-Paris 6, Centre de Recherche de l' Institut du Cerveau et de la Moelle epiniere, UMR-S975, Paris (France); Inserm, Paris (France); CNRS, Paris (France); ICM-Institut du Cerveau et de la Moelle epiniere, Paris (France); Groupe Hospitalier Pitie-Salpetriere, Department of Neurology, Institut de la Memoire et de la Maladie d' Alzheimer-IM2A, Paris Cedex 13 (France); Mutlu, Gurkan [Groupe Hospitalier Pitie-Salpetriere, Urgences Cerebro-Vasculaires, Universite Pierre et Marie Curie-Paris 6, Paris Cedex 13 (France); Hopital Saint-Louis, Inserm, Universite Paris 7-Denis Diderot, Paris (France); Pellot, Audrey [Groupe Hospitalier Pitie-Salpetriere, Department of Neuroradiology, AP-HP, Paris Cedex 13 (France); Collaboration: And the Alzheimer' s Disease Neuroimaging Initiative

    2012-12-15

    Hippocampus volumetry is a useful surrogate marker for the diagnosis of Alzheimer's disease (AD). Our purpose was to compare visual assessment of medial temporal lobe atrophy made by radiologists with automatic hippocampal volume and to compare their performances for the classification of AD, mild cognitive impairment (MCI) and cognitively normal (CN). We studied 30 CN, 30 MCI and 30 AD subjects. Six radiologists with two levels of expertise performed two readings of medial temporal lobe atrophy. Medial temporal lobe atrophy was evaluated on coronal three-dimensional T1-weighted images using Scheltens scale and compared with hippocampal volume obtained using a fully automatic segmentation method (Spearman's rank coefficient). Visual assessment of medial temporal lobe atrophy was correlated with hippocampal volume (p < 0.01). Classification performances between MCI converter and CN was better using volumetry than visual assessment of non-expert readers whereas classification of AD and CN did not differ between visual assessment and volumetry except for the first reading of one non-expert (p = 0.03). Visual assessment of medial temporal lobe atrophy by radiologists was well correlated with hippocampal volume. Radiological assessment is as good as computer-based volumetry for the classification of AD, MCI non-converter and CN and less good for the classification of MCI converter versus CN. Use of Scheltens scale for assessing hippocampal atrophy in AD seems thus justified in clinical routine. (orig.)

  3. Computer-based radiological longitudinal evaluation of meningiomas following stereotactic radiosurgery.

    Science.gov (United States)

    Shimol, Eli Ben; Joskowicz, Leo; Eliahou, Ruth; Shoshan, Yigal

    2018-02-01

    Stereotactic radiosurgery (SRS) is a common treatment for intracranial meningiomas. SRS is planned on a pre-therapy gadolinium-enhanced T1-weighted MRI scan (Gd-T1w MRI) in which the meningioma contours have been delineated. Post-SRS therapy serial Gd-T1w MRI scans are then acquired for longitudinal treatment evaluation. Accurate tumor volume change quantification is required for treatment efficacy evaluation and for treatment continuation. We present a new algorithm for the automatic segmentation and volumetric assessment of meningioma in post-therapy Gd-T1w MRI scans. The inputs are the pre- and post-therapy Gd-T1w MRI scans and the meningioma delineation in the pre-therapy scan. The output is the meningioma delineations and volumes in the post-therapy scan. The algorithm uses the pre-therapy scan and its meningioma delineation to initialize an extended Chan-Vese active contour method and as a strong patient-specific intensity and shape prior for the post-therapy scan meningioma segmentation. The algorithm is automatic, obviates the need for independent tumor localization and segmentation initialization, and incorporates the same tumor delineation criteria in both the pre- and post-therapy scans. Our experimental results on retrospective pre- and post-therapy scans with a total of 32 meningiomas with volume ranges 0.4-26.5 cm[Formula: see text] yield a Dice coefficient of [Formula: see text]% with respect to ground-truth delineations in post-therapy scans created by two clinicians. These results indicate a high correspondence to the ground-truth delineations. Our algorithm yields more reliable and accurate tumor volume change measurements than other stand-alone segmentation methods. It may be a useful tool for quantitative meningioma prognosis evaluation after SRS.

  4. Prospective study to evaluate the clinical and radiological outcome of patients with scleroderma of the face.

    Science.gov (United States)

    Careta, Mariana Figueiroa; Leite, Claudia da Costa; Cresta, Fernando; Albino, Jose; Tsunami, Mirian; Romiti, Ricardo

    2013-09-01

    Scleroderma featuring rare connective tissue disease that manifests as skin sclerosis and variable systemic involvement. Two categories of scleroderma are known: systemic sclerosis, characterized by cutaneous sclerosis and visceral involvement and localized scleroderma or morphea which classically presents benign evolution and self-limited, confined to the skin and/or underlying tissue. Recent studies show that the localized form may possibly course with involvement of internal organs and variable morbidity. This study aimed to determine the demographic characteristics, the prevalence of systemic manifestations and laboratory findings, as well as the association with autoimmune diseases, and the evolution of neurological findings, both clinical as brain MRI in patients with scleroderma of the face and its relation with the activity skin. Patients with localized scleroderma with facial involvement were evaluated and underwent neurological examination, magnetic resonance imaging and ophthalmology evaluation. After 3years, the patients were subjected again to MRI. We studied 12 patients with localized scleroderma of the face. Of this total, headache being the most frequent complaint found in 66.7% of patients, 33.3% had neurological changes possibly associated with scleroderma. As for ophthalmologic evaluation, 25% of patients showed abnormalities. The most frequent parenchymal finding was the presence of lesions with hyperintense or hypointense signal in 75% of patients, followed by ventricular asymmetry at 16.7%. Of the patients who had neurological deficits, 75% also had a change to MRI. In all patients, imaging findings after 3years were unchanged. During this interval of 3years, 25% of patients showed signs of activity of scleroderma. Patients with localized scleroderma of the face have a high prevalence of neurological and ophthalmological changes. Based on these findings, we suggest that all cases of localized scleroderma of the face should be thoroughly

  5. Evaluation of effective dose in an anthropomorphic phantom in radiological emergencies situations

    International Nuclear Information System (INIS)

    Silva, Livia K. da; Ribeiro, Rosane M.; Santos, Denison de S.

    2013-01-01

    This work aims to implement the code of Monte Carlo Geant4 in a male and female phantom, ADAM and EVA, to be able to evaluate the dose in individuals who have been exposed externally to ionizing radiation sources so that in the future be made a review within the limits of validity of the terms contained in TECDOC-1162, published by the International Atomic Energy Agency (IAEA), which recommends formulas for the effective dose assessment in individuals who have been exposed to external radiation sources in various geometric configurations and for various radionuclides

  6. Clinical value of radiological methods in evaluation and therapy of severe thoracic trauma

    Energy Technology Data Exchange (ETDEWEB)

    Glinz, W.

    1987-09-01

    Plain chest radiographs allow the diagnosis of most intrathoracic injuries. However, they are only momentary pictures and give no information on the respiratory function. A tension pneumothorax, rib fractures and subcutaneous emphysema should be diagnosed clinically before radiographs are taken. Computed tomography is helpful in evaluation of intrapulmonary lesions, hemothorax, rupture of the diaphragm and dislocation of the heart. Further diagnostic tools include aortography in suspected aortic rupture, sonography in cardiac injuries and hemopericardium, bronchoscopy in suspected bronchial or tracheal rupture, ECG and enzyme determinations in cardiac contusion, and eventually pneumoperitoneum in suspected rupture of the diaphragm.

  7. Clinical value of radiological methods in evaluation and therapy of severe thoracic trauma

    International Nuclear Information System (INIS)

    Glinz, W.

    1987-01-01

    Plain chest radiographs allow the diagnosis of most intrathoracic injuries. However, they are only momentary pictures and give no information on the respiratory function. A tension pneumothorax, rib fractures and subcutaneous emphysema should be diagnosed clinically before radiographs are taken. Computed tomography is helpful in evaluation of intrapulmonary lesions, hemothorax, rupture of the diaphragm and dislocation of the heart. Further diagnostic tools include aortography in suspected aortic rupture, sonography in cardiac injuries and hemopericardium, bronchoscopy in suspected bronchial or tracheal rupture, ECG and enzyme determinations in cardiac contusion, and eventually pneumoperitoneum in suspected rupture of the diaphragm. (orig.)

  8. Radiological evaluation of ventricular septal defect with aortic insufficiency - An analysis of cineangiography in 15 cases -

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Yeon, Kyung Mo; Han, Man Chung

    1981-01-01

    Fifteen cases of ventricular septal defect with aortic insufficiency were diagnosed radiographically and confirmed after operation at Seoul National University Hospital in recent two half years since 1979. Cineangiographies of ascending aorta and left ventricle were done in those cases and revealed some characteristic findings. The results of the analysis are as follow: 1. Among the 15 cases, 14 cases were male and 1 case was female. Age distribution was from 7 years to 23 years. 2. Those 15 cases were corresponded to 8% among total 193 cases of ventricular septal defect, to 11% among total 135 cases of aortic insufficiency and especially to 48% among 48 cases of aortic insufficiency below age of 20 years. 3. After operation, 11 cases were confirmed as subpulmonary type ventricular septal defect and 4 cases as subcristal type. The sizes of the ventricular septal defects were ranged between 0.6 and 2.5 cm in diameter. 4. Regurgitation of contrast media was noticed in cine aortography of all cases, and the grades of regurgitation were II-III/IV in 13 cases. 5. Various types of herniated aortic cusp through ventricular septal defect were seen. In the cases of subpulmonary ventricular septal defect characteristic saccular aneurysm was found in 7 cases. Asymmetry or mild bulging of aortic sinus was found in the cases of subcristal ventricular septal defect. 6. Infundibular stenosis was found in 3 cases with right ventriculography and those were caused by the herniated saccular aneurysm of aortic cusp. 7. It is essential for the diagnosis of ventricular septal defect with aortic insufficiency to undertake biplane cineangiography of ascending aorta and left ventricle in long axial view and right ventriculography should be done in suspicion of infundibular pulmonary stenosis

  9. Computerized methodology for evaluating the long-range radiological impact of shallow-land burial

    International Nuclear Information System (INIS)

    Fields, D.E.; Little, C.A.; Emerson, C.J.

    1981-01-01

    A computerized methodology has been implemented to calculate the risk to local and intermediate-range (up to 80 km distant) populations resulting from water- and air-borne transport of radionuclides present in low-level wastes buried in shallow trenches such as those used at Oak Ridge. Our computer code, PRESTO (Prediction of Radiation Effects from Shallow Trench Operations), was developed under United States Environmental Protection Agency funding to evaluate possible health effects resulting from shallow burial operations. Sources of contamination include radionuclide releases from the trenches and from areas contaminated with operational spillage. The model is intended to predict radionuclide transport and the ensuing exposure and health impact to at-risk populations for a 1000-year period following cessation of burial ground operations. Several classes of submodels are used in PRESTO to represent scheduled event, unit system response, and risk evaluation processes. Examples of scheduled events are trench cap failure, stabilization of insoluble surface contaminant, the onset of farming or reclamation practices, and human intrusion. Unit system response submodels simulate processes such as infiltration of rainwater into the trench and erosion of soil overburden from the trench cover. System response submodels generate parameters used repeatedly in the 1000-year simulation loop

  10. Evaluation of the angular response of LaBr{sub 3}(Ce) and NaI(Tl) radiological identifiers for emergency situations attendance

    Energy Technology Data Exchange (ETDEWEB)

    Izidório, Ana C.A.C.; Cardoso, Domingos D’O.; Oliveira, Luciano S.R.; Balthar, Mario C.V.; Amorim, Aneuri S. de; Santos, Avelino dos; Guimarães Junior, Walter J.; Arbach, Mayara N., E-mail: carolizidorio@hotmail.com, E-mail: domingos.oliveiralvr71@gmail.com, E-mail: walter_guimaraes@ime.eb.br, E-mail: lucianosantarita@gmail.com, E-mail: mariobalthar@gmail.com, E-mail: aneurideamorim@gmail.com, E-mail: hiperav@gmail.com, E-mail: mayaraarbach@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Instituto de Defesa Química, Biológica, Radiológica e Nuclear (IDQBRN/CTEx), Barra de Guaratiba, RJ (Brazil); Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    The Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) of the Brazilian Army has been developing activities aimed at characterizing radiological detectors for use during emergency situations and radiological incidents and also for research and academic activities. This work describes the experiments performed in order to evaluate the angular response of LaBr{sub 3}(Ce) and NaI(Tl) portable radiological identifiers (PRI) with scintillator crystal detectors measuring 1.5” x 1.5” and 3.0” x 1.5”, respectively. A {sup 137}Cs source with corrected activity of 2.623 GBq (July 29, 2017) supplied the beam for the experiments. It was positioned at a distance of 1.00 m from the PRIs, together with attenuators, in order to yield different ambient dose equivalent rate, H⁎(10), thus allowing the adjustment of the counting statistics and the analysis of the responses obtained. The objective of this work was to evaluate the angular dependence of the response of LaBr{sub 3}(Ce) and NaI(Tl) PRIs exposed to a {sup 137}Cs source by azimuthally varying the angle of incidence of the primary beam within the 0° ± 30° range, measured from the center of the sensitive volume of the scintillators. The PRIs were programmed to reach a maximum count of 10{sup 6} in order to ensure that the relative uncertainty of the measured data would be negligible which led to improved angular response data, in addition to higher correlation factors and greater reliability in the responses obtained with LaBr{sub 3}(Ce) and NaI(T1) portable radiological identifiers. (author)

  11. Radiological Evaluation of the effects of varied doses of Celecoxib on fracture healing in dogs

    Directory of Open Access Journals (Sweden)

    Edwin Aihanuwa Uwagie-Ero and Rapheal Chukwujekwu Kene

    2011-04-01

    Full Text Available To determine if Cyclooxygenase -2 (COX-2 functions in fracture healing, 10 dogs were treated with COX-2-selective nonsteroidal anti-inflammatory drugs (Celecoxib to reduce and stop COX-2-dependent prostaglandin production. Radiographic testing evaluation determined that fracture healing was not affected in dogs treated with a low dose of COX-2-selective NSAIDs (celecoxib and delayed union was observed in dogs treated with a high dose of COX-2-selective NSAIDs (celecoxib. Celecoxib dose of 5 mg/kg/day did not affect fracture callus formed in the study group and did not cause a significant increase in the proportion of delayed unions, however, at a dose of 10 mg/kg/day it reduced the rate of fracture callus formation and significantly increased the proportion of delayed unions for dogs in the group. [Veterinary World 2011; 4(2.000: 75-76

  12. Traumatic structures of the prostatomembranous urethra in children: Radiologic evaluation before and after urethral reconstruction

    International Nuclear Information System (INIS)

    Haller, J.O.; Kassner, E.G.; Waterhouse, K.; Glassberg, K.I.

    1979-01-01

    Impassible strictures of the posterior urethra are frequent sequelae of injuries of the prostatomembranous urethra. To select the appropriate type of urethral reconstructive procedure, the surgeon must know the length of the stricture, whether local complications are present, and whether the anterior urethra is strictured or bound down by fibrosis. The authors describe the radiographic techniques they use to plan urethral reconstruction and evaluate the operative result. The principles of the one-stage transperineal and combined transpubic-transperineal repairs and the two-stage Turner-Warwick scrotal skin inlay urethroplasty are presented to enable radiologists and urologists to interpret contrast studies of the lower urinary tract in patients who have undergone these operation. (orig.) [de

  13. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  14. Feed particle size evaluation: conventional approach versus digital holography based image analysis

    Directory of Open Access Journals (Sweden)

    Vittorio Dell’Orto

    2010-01-01

    Full Text Available The aim of this study was to evaluate the application of image analysis approach based on digital holography in defining particle size in comparison with the sieve shaker method (sieving method as reference method. For this purpose ground corn meal was analyzed by a sieve shaker Retsch VS 1000 and by image analysis approach based on digital holography. Particle size from digital holography were compared with results obtained by screen (sieving analysis for each of size classes by a cumulative distribution plot. Comparison between particle size values obtained by sieving method and image analysis indicated that values were comparable in term of particle size information, introducing a potential application for digital holography and image analysis in feed industry.

  15. Source term and radiological consequence evaluation for nuclear accidents using a 'hand type' methodology

    International Nuclear Information System (INIS)

    Margeanu, Sorin; Tatiana, Angelescu

    2005-01-01

    In the last decades, hand type calculations have been replaced by computerized solutions, which are much more accurate, but the preparation of an input to run the code can be a time consuming process and can require a laborious work. This is why, a place for hand calculation based on nomograms still exist in some areas. An example is emergency response to an accidental release of radioactive contaminants when the health of persons close to the accident site might be at risk. In this case, results from computerized accident consequences assessment models may be delayed due to the equipment malfunction or the time required developing minimal input files and performing the calculations (typically more than five minutes). A simple nomogram (developed using computerized dispersion model calculations) can provide dispersion and dose estimates within a minute. The paper presents the methodology used for these 'hand type' calculation and the nomograms, figures and tables used to evaluate the dose to an individual close to the release point. In order to illustrate the use of methodology, a hypothetical severe accident scenario involving 14-MW INR-TRIGA research reactor was considered. (authors)

  16. Reference values for radiological evaluation of cervical vertebral body shape and spinal canal

    Energy Technology Data Exchange (ETDEWEB)

    Remes, V.M. [Hospital for Children and Adolescents, Helsinki University Central Hospital (Finland); Heinaenen, M.T.; Marttinen, E.J. [Department of Radiology, Helsinki University Central Hospital, Helsinki (Finland); Kinnunen, J.S. [Department of Radiology, Helsinki University Central Hospital, HYKS (Finland)

    2000-03-01

    Background. Defining normal values is essential for reliable evaluation of growth disturbances. Previous studies of the cervical spine have mainly focused on the sagittal canal diameter and interpedicular distances. Values for vertebral body height and depth have been published only in adult men and cadavers.Objectives. To define normal values for vertebral body height (H)/vertebral body depth (D) ratio (H/D ratio) and sagittal canal diameter (S)/vertebral body depth ratio (S/D ratio) in C2-7.Materials and methods. Lateral cervical spine radiographs were available from 441 children and 192 adults. Subjects' ages varied from newborn to 39 years. Vertebral body height and depth and sagittal canal diameter were measured and ratios were calculated. This was a cross-sectional and retrospective study.Results. Vertebral bodies grow relatively more in height than in depth, most actively at puberty. At all levels, the H/D ratio remains below 1, indicating that vertebral body depth is greater than height. The SD ratio is quite stable until 7-8 years of age and then it starts to decline slowly.Conclusions. When estimating platyspondyly, the age of the patient must be taken into consideration because vertebral body height is lower in children. Growth of the spinal canal declines after 7-8 years of age. (orig.)

  17. Reference values for radiological evaluation of cervical vertebral body shape and spinal canal

    International Nuclear Information System (INIS)

    Remes, V.M.; Heinaenen, M.T.; Marttinen, E.J.; Kinnunen, J.S.

    2000-01-01

    Background. Defining normal values is essential for reliable evaluation of growth disturbances. Previous studies of the cervical spine have mainly focused on the sagittal canal diameter and interpedicular distances. Values for vertebral body height and depth have been published only in adult men and cadavers.Objectives. To define normal values for vertebral body height (H)/vertebral body depth (D) ratio (H/D ratio) and sagittal canal diameter (S)/vertebral body depth ratio (S/D ratio) in C2-7.Materials and methods. Lateral cervical spine radiographs were available from 441 children and 192 adults. Subjects' ages varied from newborn to 39 years. Vertebral body height and depth and sagittal canal diameter were measured and ratios were calculated. This was a cross-sectional and retrospective study.Results. Vertebral bodies grow relatively more in height than in depth, most actively at puberty. At all levels, the H/D ratio remains below 1, indicating that vertebral body depth is greater than height. The SD ratio is quite stable until 7-8 years of age and then it starts to decline slowly.Conclusions. When estimating platyspondyly, the age of the patient must be taken into consideration because vertebral body height is lower in children. Growth of the spinal canal declines after 7-8 years of age. (orig.)

  18. Evaluation of the practical peak voltage quantity for clinical equipment in diagnostic radiology

    International Nuclear Information System (INIS)

    Pires, Joao dos Santos Justo

    2007-01-01

    The objective of this work is to evaluate the calculation of the Practical Peak Voltage (PPV) from the voltage waveform and the kerma contrast for two kinds of X-ray equipment: a single phase clinical equipment, a three phase clinical equipment. The PPV from a mammography system voltage waveform will also be established. The development of this work involves intermediate objectives that indicate the quality of the used methods to calculate the PPV. One of these intermediate objectives is the comparison between the invasive calculations of PPV (using a voltage divider) with the response of kVp meter that calculate the PPV. Another intermediate objective is to compare the PPV with the Contrast Equivalent Voltage (the original non-invasive PPV definition). The variation of the PPV with quantities that influence in the voltage waveform like ripple and sample rate will also be contemplated in this work. The results showed that the PPV quantity could be invasive determined trustworthy. Therefore, the ripple quantity is the mainly influence to determinate the PPV that affecting the non-invasive determination. This fact suggest that the non-invasive instruments manufacturers must reevaluate the calculation of the PPV quantity in their instruments. (author)

  19. Evaluating phantom image quality parameters to optimise patient radiation dose in dental digital radiology.

    Science.gov (United States)

    Gonzalez, Luciano; Vano, Eliseo; Fernandez, Ramon; Ziraldo, Viviana; Delgado, Jaime; Delgado, Victor; Moro, Javier; Ubeda, Carlos

    2012-08-01

    Our objective was to obtain images of a predictable level of quality using an intraoral X-ray system with digital imaging, avoiding patient overexposure. A polymethylmethacrylate (PMMA) physical test phantom was imaged at different exposure times and at various PMMA thicknesses using a dental imaging coupled charge device. Two identical regions of interest (ROIs) were chosen in every image file, and quality was numerically evaluated by measuring high-contrast spatial resolutions, low-contrast thresholds and signal-to-noise ratios. In addition, three practitioners proposed personal quality scores by image inspection. Numerical contents in the ROIs, related to the image quality, were plotted against exposure time. From here, a simple expression linking the exposure time with the thickness to obtain images of comparable quality was deduced. As a result, the optimum exposure time for imaging with a predictable level of quality can be inferred. The potential effect could imply savings above 1000 man Sv, roughly 20 % of the collective dose due to dental imaging, over a population of 1540 millions.

  20. Formative evaluation of a mobile liquid portion size estimation interface for people with varying literacy skills.

    Science.gov (United States)

    Chaudry, Beenish Moalla; Connelly, Kay; Siek, Katie A; Welch, Janet L

    2013-12-01

    Chronically ill people, especially those with low literacy skills, often have difficulty estimating portion sizes of liquids to help them stay within their recommended fluid limits. There is a plethora of mobile applications that can help people monitor their nutritional intake but unfortunately these applications require the user to have high literacy and numeracy skills for portion size recording. In this paper, we present two studies in which the low- and the high-fidelity versions of a portion size estimation interface, designed using the cognitive strategies adults employ for portion size estimation during diet recall studies, was evaluated by a chronically ill population with varying literacy skills. The low fidelity interface was evaluated by ten patients who were all able to accurately estimate portion sizes of various liquids with the interface. Eighteen participants did an in situ evaluation of the high-fidelity version incorporated in a diet and fluid monitoring mobile application for 6 weeks. Although the accuracy of the estimation cannot be confirmed in the second study but the participants who actively interacted with the interface showed better health outcomes by the end of the study. Based on these findings, we provide recommendations for designing the next iteration of an accurate and low literacy-accessible liquid portion size estimation mobile interface.

  1. Evaluation of nondestructive evaluation size measurement for integrity assessment of axial outside diameter stress corrosion cracking in steam generator tubes

    International Nuclear Information System (INIS)

    Joo, Kyung Mun; Hong, Jun Hee

    2015-01-01

    Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy 600 HTMA tubes has been increasing. As a result, SGs with Alloy 600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and ability of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

  2. Evaluation of nondestructive evaluation size measurement for integrity assessment of axial outside diameter stress corrosion cracking in steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Kyung Mun [Korea Hydro and Nuclear Power Company Ltd., Central Research Institute, Daejeon (Korea, Republic of); Hong, Jun Hee [Dept. of mechanical Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-02-15

    Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy 600 HTMA tubes has been increasing. As a result, SGs with Alloy 600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and ability of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

  3. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  4. Evaluation of laser-induced breakdown spectroscopy analysis potential for addressing radiological threats from a distance

    International Nuclear Information System (INIS)

    Gaona, I.; Serrano, J.; Moros, J.; Laserna, J.J.

    2014-01-01

    Although radioactive materials are nowadays valuable tools in nearly all fields of modern science and technology, the dangers stemming from the uncontrolled use of ionizing radiation are more than evident. Since preparedness is a key issue to face the risks of a radiation dispersal event, development of rapid and efficient monitoring technologies to control the contamination caused by radioactive materials is of crucial interest. Laser-induced breakdown spectroscopy (LIBS) exhibits appealing features for this application. This research focuses on the assessment of LIBS potential for the in-situ fingerprinting and identification of radioactive material surrogates from a safe distance. LIBS selectivity and sensitivity to detect a variety of radioactive surrogates, namely 59 Co, 88 Sr, 130 Ba, 133 Cs, 193 Ir and 238 U, on the surface of common urban materials at a distance of 30 m have been evaluated. The performance of the technique for nuclear forensics has been also studied on different model scenarios. Findings have revealed the difficulties to detect and to identify the analytes depending on the surface being interrogated. However, as demonstrated, LIBS shows potential enough for prompt and accurate gathering of essential evidence at a number of sites after the release, either accidental or intentional, of radioactive material. The capability of standoff analysis confers to LIBS unique advantages in terms of fast and safe inspection of forensic scenarios. The identity of the radioactive surrogates is easily assigned from a distance and the sensitivity to their detection is in the range of a few hundreds of ng per square centimeter. - Highlights: • Distant identification of radioactive surrogates on urban surfaces has been proved. • LIBS sensitivity to distant detection of radioactive surrogates has been checked. • Influences of the atmosphere on emission signals have been ascertained. • Usage of standoff LIBS for identifying forensic evidences has been

  5. Evaluation Of The Radiological Situation In Algeria After The Algeciras Incident

    Directory of Open Access Journals (Sweden)

    A. NOUREDDINE

    2003-12-01

    Full Text Available The present study has been carried out in the framework of our environmental monitoring programme and immediately after being informed by the IAEA of possible accidental releases of 137 Cs into the air, which might have been released between May 25 th and the first of June 1998 from the Acerinox factory in Algeciras (Spain. Algericas is the region where a steel-processing factory has been set up. During the work procedure, a radioactive source of 137 Cs passed through the furnace resulting in accidental releases into the atmosphere. This radioactive contamination was detected in France, Switzerland, Italy and Germany, and some radioactivity measurements were carried out by the Commissariat A l'Energie Atomique to evaluate the gamma radiation status in areas selected in Algeria. The approach adopted in our case was to start in situ gamma-radiation measurements and to collect air and soil samples as well from a selected area in Algiers. Afterwards, and in order to have more reliable results, a sampling program was carried out in July 1998, in the frame of which some sampling stations were established in the west of Algeria, based upon Algerian meteorological data during the period of incident. A total number of 16 environmental samples from 9 stations, namely, soil, sediment, vegetation and seawater were collected, followed by in situ gamma radiation measurements in each sampling location. Soil, sediment and vegetation samples were analysed by direct gamma spectrometry, whereas, sea water samples were analysed radiochemically using microcrystalline AMP for coprecipitation and gamma counted. Taking into consideration the background levels of radioactivity in the studied areas, obtained by our previous monitoring programs, the results obtained do not show any increase of 137 Cs resulting from the incinerated Caesium source in the Acerinox steel factory in Algeciras, Spain. The conclusion drawn by this work is that the investigated area was not

  6. Evaluation of release amount of radioactivity from Chernobyl accident and of resulting radiological consequence in China

    International Nuclear Information System (INIS)

    Zhang Yongxing

    1987-01-01

    Three kinds of methods are used to evaluate the release amount from Chernoby1 RBMK-1000 reactor accident, i.e. (1) estimation by comparison with Windscale accident; (2) estimation in terms of the stock in the core; and (3) estimation according to the available monitoring data form adjacent countries such as Poland and Finland. The results obtained are as follows: the release of I-131 was 0.1-1.5 EBq, which is approximately 4-50% of the stock in the core; the release amount of Ru-103 was comparable to that of Cs-137, both approximately 5-10% of that of I-131; the volatile nuclides such as Mo-99, Ru-103, Te-132, Cs-137 etc., were in the order of 0.4 EBq; involatile nuclides were 0.2 EBq; noble gases and other fission products 10 EBq; and the total amount released was about 20 EBq, which taken together 8% of the stock in the core. The radioactive cloud cluster passed through over the area of China in the beginning of May. It was estimated that the total amount of I-131 in air over China area was about 1.6 PB q , Cs-137 about 0.3 PB q , Ru-103 about 0.2 PB q ; the total fallout in the area of China was about 3 PB q for I-131, about 0.1 PB q for Cs-137, about 0.3 PB q for Ru-103. The resulting effective dose equavalent commitment to critical group individual was about 60 μSv, collective effective dose equavalent commitment received by the population of China was about 1 x 10 4 man.Sv

  7. Evaluation of laser-induced breakdown spectroscopy analysis potential for addressing radiological threats from a distance

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, I.; Serrano, J.; Moros, J.; Laserna, J.J., E-mail: laserna@uma.es

    2014-06-01

    Although radioactive materials are nowadays valuable tools in nearly all fields of modern science and technology, the dangers stemming from the uncontrolled use of ionizing radiation are more than evident. Since preparedness is a key issue to face the risks of a radiation dispersal event, development of rapid and efficient monitoring technologies to control the contamination caused by radioactive materials is of crucial interest. Laser-induced breakdown spectroscopy (LIBS) exhibits appealing features for this application. This research focuses on the assessment of LIBS potential for the in-situ fingerprinting and identification of radioactive material surrogates from a safe distance. LIBS selectivity and sensitivity to detect a variety of radioactive surrogates, namely {sup 59}Co, {sup 88}Sr, {sup 130}Ba, {sup 133}Cs, {sup 193}Ir and {sup 238}U, on the surface of common urban materials at a distance of 30 m have been evaluated. The performance of the technique for nuclear forensics has been also studied on different model scenarios. Findings have revealed the difficulties to detect and to identify the analytes depending on the surface being interrogated. However, as demonstrated, LIBS shows potential enough for prompt and accurate gathering of essential evidence at a number of sites after the release, either accidental or intentional, of radioactive material. The capability of standoff analysis confers to LIBS unique advantages in terms of fast and safe inspection of forensic scenarios. The identity of the radioactive surrogates is easily assigned from a distance and the sensitivity to their detection is in the range of a few hundreds of ng per square centimeter. - Highlights: • Distant identification of radioactive surrogates on urban surfaces has been proved. • LIBS sensitivity to distant detection of radioactive surrogates has been checked. • Influences of the atmosphere on emission signals have been ascertained. • Usage of standoff LIBS for identifying

  8. Characteristics and trends of radiology research: a survey of original articles published in AJR and Radiology between 2001 and 2010.

    Science.gov (United States)

    Lim, Kyoung Ja; Yoon, Dae Young; Yun, Eun Joo; Seo, Young Lan; Baek, Sora; Gu, Dong Hyeon; Yoon, Soo Jeong; Han, Ari; Ku, You Jin; Kim, Sam Soo

    2012-09-01

    To determine the characteristics and trends of the original articles published in two major American radiology journals, AJR American Journal of Roentgenology (AJR) and Radiology, between 2001 and 2010. This was a retrospective bibliometric analysis that did not involve human subjects and was exempt from institutional review board approval. All 6542 original articles published in AJR and Radiology between 2001 and 2010 were evaluated. The following information was abstracted from each article: radiologic subspecialty, radiologic technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, affiliation of the first author, and country of the first author. In addition, all the variables examined were presented along with the trend over time. The most common subspecialty of study was abdominal (1219 of 6542, 18.6%), followed by vascular/interventional (804 of 6542, 12.3%). A total of 3744 (57.2%) original articles used magnetic resonance (MR) imaging or computed tomography (CT), 5495 (84.1%) were clinical research articles, 3060 (46.8%) had sample size of more than 50, 4087 (62.5%) were retrospective, 4714 (72.1%) performed statistical analysis, 6225 (95.2%) showed positive study outcome, 4784 (73.1%) were not funded, 3942 (60.3%) had four to seven authors, and 5731 (87.6%) were written by the primary author who was from a department of radiology or radiology-related specialties. The United States published 45.5% (2975 of 6542) of the articles, followed by Japan (n = 525, 8.0%), Germany (n = 485, 7.4%), and South Korea (n = 455, 7.0%). In the time trend analysis, the following variables showed a significantly positive trend: cardiac subspecialty, CT and MR imaging as the radiologic techniques, type of research as other (nonbasic, nonclinical), sample size of more than 50, four to seven as the number of authors, medicine-related department of the first author, and South Korea and Italy as

  9. CLINICAL AND RADIOLOGICAL EVALUATION OF NEW - ONSET EPILETIC SEIZURES IN A TERTIARY CARE HOSPITAL

    Directory of Open Access Journals (Sweden)

    Chalapathi Rao

    2015-09-01

    Full Text Available BACKGROUND: Epilepsy is one of the most familiar neurological disorders which can cause bodily injury and death from inadequately treated or untreated cases. The imaging and EEG of new onset seizures is done with different indications, to identify an acute illness as the underline course for the seizure and possible neurological deficit. To this purpose we have evaluated new onset seizures in adult patients in correlation with their clinical profile, Electroencephalography (EEG and Computerized tomography (CT imaging of brain. METHODS: This cro ss sectional study was studied in 100 adult patients, presenting with seizures attending the Emergency department, General Medicine and Neurology wards and OPD of Tertiary care teaching hospital during the period of March 2006 to March 2008. All the patien ts were examined clinically and subjected to CT imaging of brain and EEG. Other necessary blood investigations were also done. Correlation between various seizures and CT scan brain and EEG were studied. Descriptive statistics were used to analyze the data . RESULTS: 63% of patients were in the age group of 20 - 39 years, 63% were males and 37% were females. 65% presented with GTCS, 35% with partial seizures. CT scan was found abnormal in 49.2% patients in GTCS, 71.4% in partial seizures. EEG showed abnormal p attern in 39% patients. 40% of the patients with partial seizures had epileptic form discharges. 33% patients had focal lesions on CT brain with normal EEG. CONCLUSION: Generalized Tonic clonic seizures were the commonest type of seizures was present, seen mostly in male patients. CT scan brain was abnormal in 57% of the patients. Neurocysticercosis and calcified granuloma were the commonest causes for seizures up to 3 rd decade of life. Majority of the patients with focal lesions on CT scan brain had epileptic form discharges on EEG which indicate a strong correlation of EEG with CT findings. Initiating the treatment with antiepileptic drugs was

  10. Standalone Photovoltaic System Sizing using Peak Sun Hour Method and Evaluation by TRNSYS Simulation

    OpenAIRE

    Riza, Dimas Firmanda Al; Gilani, Syed Ihtshamul-Haq

    2016-01-01

    This paper presents sizing and evaluation of a standalone photovoltaic system for residential load. Peak Sun Hour method is used to determine photovoltaic panel and battery capacity, then the sizing results is tested and evaluated using hourly time-step transient simulation model by using TRNSYS 16.0. The results shows for typical Malaysian terraced house that have about 6 kWh daily electricity load, the photovoltaic system requirement consist of 1.9 kWp photovoltaic panel and 2200 Ah battery...

  11. Radiological impact evaluation of an uranium mine in an agricultural soil

    International Nuclear Information System (INIS)

    Szeles, Marlene Sotto-Mayor Flues

    1994-01-01

    The contamination of a soil near an uranium mine exhaust ventilating shaft was evaluated. The methodology adopted proved to be successful even for facilities which do not present any preoperational or operational results. The activity concentration of 210 Pb, 238 U, 226 Ra, 228 Ra, 137 Cs and 40 K was measured along a transect of 200m on a field located in the exhaust air direction. The data showed that the activity increased due to the emissions from the mine. The largest effect was observed for 210 Pb, whereas smaller effects were observed for 238 U and 226 Ra. The activity ratios of 210 Pb/ 238 U and 238 U/ 226 Ra in the soil for distances where the contamination was not detectable anymore, were 1,04 and 1,43 , respectively. These results are in good agreement with other data found in the literature. The semivariograms of the activity concentration of the radionuclides at distances, where the effect of the emissions from the mine was not any longer observable, indicated for 210 Pb and 226 Ra the presence of a range (30m and 40m, respectively) within which the variance attains its maximum value. The semivariogram observed for 40 K, showed a wider range, indicating the influence of an uneven fertilizers application. A sequential extraction procedure was applied to investigate the speciation of the radionuclides and stable Pb in the soil. The following extractions were carried out: fraction I readily exchangeable, fraction II bound to carbonates and fraction III bound to Fe and Mn oxides. In the soil near the exhaust air the extraction was more effective for 210 Pb, 238 U and 226 Ra . The radionuclide 210 Pb was more extracted in fraction I and III, whereas 238 U and 226 Ra were similarly extracted in fraction II and III. The behaviour of 210 Pb was different for the control soil and the agricultural soil. In the control soil 210 Pb was more extracted in fraction II and III, whereas in the the agricultural soil it was more extracted in fraction I and III. Stable Pb

  12. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  13. Emergency radiology

    International Nuclear Information System (INIS)

    Keats, T.E.

    1986-01-01

    This book is the German, translated version of the original published in 1984 in the U.S.A., entitled 'Emergency Radiology'. The publication for the most part is made up as an atlas of the radiological images presenting the findings required for assessment of the emergency cases and their first treatment. The test parts' function is to explain the images and give the necessary information. The material is arranged in seven sections dealing with the skull, the facial part of the skull, the spine, thorax, abdominal region, the pelvis and the hip, and the limbs. With 690 figs [de

  14. Postoperative radiology

    International Nuclear Information System (INIS)

    Burhenne, H.J.

    1989-01-01

    This paper reports on the importance of postoperative radiology. Most surgical procedures on the alimentary tract are successful, but postoperative complications remain a common occurrence. The radiologist must be familiar with a large variety of possible surgical complications, because it is this specialty that is most commonly called on to render a definitive diagnosis. The decision for reoperation, for instance, is usually based on results from radiologic imaging techniques. These now include ultrasonography, CT scanning, needle biopsy, and interventional techniques in addition to contrast studies and nuclear medicine investigation

  15. Evaluating factors affecting the permeability of emulsions used to stabilize radioactive contamination from a radiological dispersal device.

    Science.gov (United States)

    Fox, Garey A; Medina, Victor F

    2005-05-15

    Present strategies for alleviating radioactive contamination from a radiological dispersal device (RDD) or dirty bomb involve either demolishing and removing radioactive surfaces or abandoning portions of the area near the release point. In both cases, it is imperative to eliminate or reduce migration of the radioisotopes until the cleanup is complete or until the radiation has decayed back to acceptable levels. This research investigated an alternative strategy of using emulsions to stabilize radioactive particulate contamination. Emergency response personnel would coat surfaces with emulsions consisting of asphalt or tall oil pitch to prevent migration of contamination. The site can then be evaluated and cleaned up as needed. In order for this approach to be effective, the treatment must eliminate migration of the radioactive agents in the terror device. Water application is an environmental condition that could promote migration into the external environment. This research investigated the potential for water, and correspondingly contaminant, migration through two emulsions consisting of Topein, a resinous byproduct during paper manufacture. Topein C is an asphaltic-based emulsion and Topein S is a tall oil pitch, nonionic emulsion. Experiments included water adsorption/ mobilization studies, filtration tests, and image analysis of photomicrographs from an environmental scanning electron microscope (ESEM) and a stereomicroscope. Both emulsions were effective at reducing water migration. Conductivity estimates were on the order of 10(-80) cm s(-1) for Topein C and 10(-7) cm s(-1) for Topein S. Water mobility depended on emulsion flocculation and coalescence time. Photomicrographs indicate that Topein S consisted of greater and more interconnected porosity. Dilute foams of isolated spherical gas cells formed when emulsions were applied to basic surfaces. Gas cells rose to the surface and ruptured, leaving void spaces that penetrated throughout the emulsion. These

  16. Functional and radiological evaluation of acute acromioclavicular dislocation treated with anchors without eyelet: comparison with other techniques

    Directory of Open Access Journals (Sweden)

    Alexandre Tadeu do Nascimento

    Full Text Available ABSTRACT OBJECTIVE: To assess the repair results of acromioclavicular dislocations (ACJD grades III and V, with anchors without eyelet, when compared with other techniques, and to evaluate factors that can affect the final result. METHODS: A retrospective study of 36 patients with ACJD grades III and V in the Rockwood classification, 12 treated with anchors without eyelet, 11 with one tightrope, six with two tightropes, and six with subcoracoid cerclage, operated from September 2012 to February 2015. Patients were assessed radiographically and through DASH, UCLA, the visual analog scale of pain (VAS and the Short-Form 36 (SF-36. Surgical time and the possible influence of some factors in the outcome were also assessed. RESULTS: The mean DASH score was 6.7; UCLA, 32.9; VAS, 1.2; and SF-36, 79.47. Radiographically, the final mean measurement was 9.93 mm, with no statistical difference between the groups. The mean surgical time for Group I was 31 min; Group II, 19 min; Group III, 29 min; and Group IV, 59 min. There was a significant difference between Groups II and IV when compared with the study group. The initial and immediate post-operative ACJD measurements ACJD were correlated with the final measure. CONCLUSION: The repair of acute ACJD with anchors without eyelet is as effective as the other methods, with significantly shorter operative time when compared with the subcoracoid cerclage technique. The final radiological result is influenced by the coracoclavicular initial distance and the immediate postoperative measurement.

  17. Radiology in emergency medicine

    International Nuclear Information System (INIS)

    Levy, R.; Barsan, W.G.

    1986-01-01

    This book gives a discussion of radiologic modalities currently being used in emergency situations. Radiographs, echocardiographs, radionuclide scans and CT scans are systematically analyzed and evaluated to provide a step-by-step diagnostic process for emergency physicians to follow when a radiologist is not present

  18. Synopsis of radiologic anatomy

    International Nuclear Information System (INIS)

    Meschan, I.

    1987-01-01

    The book is a compact version of earlier publications that appeared in 1975 as a one- and a two-volume issue under the title 'Atlas of Radiologic Anatomy'. A chapter on computed tomography has been added as this novel technique requires a new approach to radiologic anatomy. The radiologist will find all the information on the anatomic conditions he needs for analysing radiographs and CT pictures. More than 600 radiographs and CT pictures are given that illustrate typical and rare findings. The book also is useful as a source of reference for making good radiographs and evaluating the quality of radiographs or CT pictures. With 1413 figs., 18 tabs [de

  19. SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

    Energy Technology Data Exchange (ETDEWEB)

    Tonkopi, E; Lightfoot, C [Dalhousie University, Queen Elizabeth II Health Sciences Ctr, Halifax, NS (Canada); LeBlanc, E [Queen Elizabeth II Health Sciences Ctr, Halifax, NS (Canada)

    2016-06-15

    Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. The larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of

  20. Optimal plot size in the evaluation of papaya scions: proposal and comparison of methods

    Directory of Open Access Journals (Sweden)

    Humberto Felipe Celanti

    Full Text Available ABSTRACT Evaluating the quality of scions is extremely important and it can be done by characteristics of shoots and roots. This experiment evaluated height of the aerial part, stem diameter, number of leaves, petiole length and length of roots of papaya seedlings. Analyses were performed from a blank trial with 240 seedlings of "Golden Pecíolo Curto". The determination of the optimum plot size was done by applying the methods of maximum curvature, maximum curvature of coefficient of variation and a new proposed method, which incorporates the bootstrap resampling simulation to the maximum curvature method. According to the results obtained, five is the optimal number of seedlings of papaya "Golden Pecíolo Curto" per plot. The proposed method of bootstrap simulation with replacement provides optimal plot sizes equal or higher than the maximum curvature method and provides same plot size than maximum curvature method of the coefficient of variation.

  1. Quantitative evaluation in tumor SPECT and the effect of tumor size. Fundamental study with phantom

    International Nuclear Information System (INIS)

    Togawa, Takashi; Yui, Nobuharu; Kinoshita, Fujimi; Yanagisawa, Masamichi

    1997-01-01

    An experimental study with phantoms was performed in order to evaluate the effect of the tumor volume on the quantitative estimation in tumor SPECT. The ratio of mean count/pixel in the phantom to that of the background (T/N ratio) was well correlated with the size of the phantom; even when the concentration of the Tc-99m O 4 - solution of globular phantoms with diameters of 29, 37 and 46 mm was constant, the greater the size of the phantom, the higher was the T/N ratio. This study showed that we should understand that the T/N ratio was certainly affected by the reduction of the tumor size itself whenever we evaluate treatment response or assess tumor viability after treatment by reference to the T/N ratio. (author)

  2. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  3. Evaluation of radiological workstations and web-browser-based image distribution clients for a PACS project in hands-on workshops

    International Nuclear Information System (INIS)

    Boehm, Thomas; Handgraetinger, Oliver; Voellmy, Daniel R.; Marincek, Borut; Wildermuth, Simon; Link, Juergen; Ploner, Ricardo

    2004-01-01

    The methodology and outcome of a hands-on workshop for the evaluation of PACS (picture archiving and communication system) software for a multihospital PACS project are described. The following radiological workstations and web-browser-based image distribution software clients were evaluated as part of a multistep evaluation of PACS vendors in March 2001: Impax DS 3000 V 4.1/Impax Web1000 (Agfa-Gevaert, Mortsel, Belgium); PathSpeed V 8.0/PathSpeed Web (GE Medical Systems, Milwaukee, Wis., USA); ID Report/ID Web (Image Devices, Idstein, Germany); EasyVision DX/EasyWeb (Philips Medical Systems, Eindhoven, Netherlands); and MagicView 1000 VB33a/MagicWeb (Siemens Medical Systems, Erlangen, Germany). A set of anonymized DICOM test data was provided to enable direct image comparison. Radiologists (n=44) evaluated the radiological workstations and nonradiologists (n=53) evaluated the image distribution software clients using different questionnaires. One vendor was not able to import the provided DICOM data set. Another vendor had problems in displaying imported cross-sectional studies in the correct stack order. Three vendors (Agfa-Gevaert, GE, Philips) presented server-client solutions with web access. Two (Siemens, Image Devices) presented stand-alone solutions. The highest scores in the class of radiological workstations were achieved by ID Report from Image Devices (p<0.005). In the class of image distribution clients, the differences were statistically not significant. Questionnaire-based evaluation was shown to be useful for guaranteeing systematic assessment. The workshop was a great success in raising interest in the PACS project in a large group of future clinical users. The methodology used in the present study may be useful for other hospitals evaluating PACS. (orig.)

  4. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  5. Aerosol particle size distribution in building and caves: impact to the radon-related dose evaluation

    International Nuclear Information System (INIS)

    Berka, Z.; Thinova, L.; Brandejsova, E.; Zdimal, V.; Fronka, A.; Milka, D.

    2004-01-01

    The results of evaluation of the aerosol particle size spectra observed in the Bozkov cave are presented and compared with the spectra observed in residential areas. The radon-to-dose conversion factor is discussed, as is the correction factor referred to as the cave factor. (P.A.)

  6. A Plan for the Evaluation of California's Class Size Reduction Initiative.

    Science.gov (United States)

    Kirst, Michael; Bomstedt, George; Stecher, Brian

    In July 1996, California began its Class Size Reduction (CSR) Initiative. To gauge the effectiveness of this initiative, an analysis of its objectives and an overview of proposed strategies for evaluating CSR are presented here. An outline of the major challenges that stand between CSR and its mission are provided. These include logistical…

  7. Size exclusion HPLC of proteins for evaluation of durum wheat quality

    Science.gov (United States)

    The present research aimed to assess size exclusion HPLC (SE-HPLC) in protein molecular weight distribution determination for quality evaluation of durum semolina. Semolina samples were milled from 13 durum genotypes grown at 7 locations in 2009 and 2010 in ND. Sodium dodecyl sulfate (SDS) buffer ...

  8. [Sample size calculation in clinical post-marketing evaluation of traditional Chinese medicine].

    Science.gov (United States)

    Fu, Yingkun; Xie, Yanming

    2011-10-01

    In recent years, as the Chinese government and people pay more attention on the post-marketing research of Chinese Medicine, part of traditional Chinese medicine breed has or is about to begin after the listing of post-marketing evaluation study. In the post-marketing evaluation design, sample size calculation plays a decisive role. It not only ensures the accuracy and reliability of post-marketing evaluation. but also assures that the intended trials will have a desired power for correctly detecting a clinically meaningful difference of different medicine under study if such a difference truly exists. Up to now, there is no systemic method of sample size calculation in view of the traditional Chinese medicine. In this paper, according to the basic method of sample size calculation and the characteristic of the traditional Chinese medicine clinical evaluation, the sample size calculation methods of the Chinese medicine efficacy and safety are discussed respectively. We hope the paper would be beneficial to medical researchers, and pharmaceutical scientists who are engaged in the areas of Chinese medicine research.

  9. Radiologic evaluation of bronchiectasis

    International Nuclear Information System (INIS)

    Ahn, Sang Won; Kang, Soo Yeon; Kim, Jong Deok; Chung, Duck Hwan

    1987-01-01

    Bronchiectasis is not an infrequent disease in Korea and is defined as irreversible abnormal dilatation of one or more bronchi. Bronchography is the definitive method of establishing the diagnosis, extent, and severity of bronchiectasis and its performance is essential to the surgeon before the operative procedure is begun. Retrospectively we reviewed 131 patients of bronchiectasis diagnosed by bronchography during the recent 5 years from January, 1982 to December, 1986 and obtained the following results: 1. Male to female ratio was 64:67, and peak incidence was between 21 and 40 year of age (68.7%:90/131) with 31.9 of mean age. 2. Chronic coughing, productive sputum, and blood-tinged sputum or hemoptysis were the three predominant symptoms, and duration of the symptoms was less than 5 years in 67.9%. 3. Among the presumptive etiologic factors, pulmonary tuberculosis was the most common one (33.6%: 44/131). interestingly, bronchial obstruction due to tracheal cancer, bronchial adenoma, and right upper mediastinal neurofibroma were also present in one case each. 4. In 91.6% of patients, plain chest film was abnormal, and one of the more unusual abnormal findings (which was beyond of our expectations) was typical right middle lobe collapse(7.6%: 10/31). 5. Left lower lobe (67.2%), lingular segment (52.0%), and right lower lobe (35.1%) were the three most frequent sites of involvement. 6. Among the basal segments, the superior segment was involved in half of the incidence because its anatomical relationship to the others made natural drainage easy. 7. Cylindrical type was the most common bronchographic finding (43.5%: 57/131)

  10. Evaluation of the atmospheric stability and it influence in the radiological environmental impact of the treatment plant and radioactive waste storage (PTDR)

    International Nuclear Information System (INIS)

    Ramos V, E.O.; Cornejo D, N.

    2006-01-01

    It is well-known that the meteorological variables as the atmospheric stability, influence in the atmospheric dispersion of radioactive pollutants, for that as regards radiological safety, it constitutes a demand the evaluation of their impact in the process before mentioned. The present work exposes the results of the study of the radiological impact of our PTDR that it allowed to know the influence of this meteorological parameter in the atmospheric dispersion of radioactive pollutants in its location. To such effects they were processed by means of the methodology of Pasquill - Gifford, data of time zone observations of this meteorological variable obtained in the proximities of the installation, being modeled the worst conditions in atmospheric liberation of their radionuclides inventory, valuing stops the 2 critical considered population groups the doses received by inhalation of polluted air and ingestion of water and polluted products, as well as, for external irradiation from the radioactive cloud and the floor. The obtained annual effective doses due to the modeling situation reach until a mSv, except for the Ra-226 that are lightly superior, implying a risk radiological acceptable chord to the international standard. To the above-mentioned a reduced probability of occurrence of events initiators of the evaluated accidental sequence is added. (Author)

  11. Evaluation of the radiologic potential due to the nuclear submarine visits to the Rio de Janeiro port

    International Nuclear Information System (INIS)

    Pereira, Jose Francisco

    2004-01-01

    Brazil is signatory of international protocols related to the visit of nuclear-powered vessels, aircraft carriers and submarines to Brazilian ports. The submarines, during their stay in Brazilian ports, inform that there is no release of radioactive material to the environment. However, the possibility of occurrence of accidents with environmental releases from PWR reactors is real. Between 1993 and 2003, 13 nuclear submarines visited Brazilian ports. This work aimed to evaluate the potential impact due to the visits of nuclear-powered ships and submarines to the port of the city of Rio de Janeiro, in relation to releases of radioactive materials to the environment, considering both routine releases and accidental situations. The models selected to perform the assessments took into account the scenarios to be simulated. Simple, but conservative methodologies were used for the evaluation of routine releases. For accidental releases, the dynamics of the materials dispersion into the environment were considered. The present study was mainly focalized on the initial phase of an accident. The doses for the crew of the Brazilian navy ships, for IRD teams performing environmental monitoring, and for the population around the Guanabara Bay, close to the points of anchorage, were assessed. The results indicated that, in normal operational conditions, no significant radiological impact due to the visit of nuclear submarines to the port of the city of Rio de Janeiro is expected, even considering the occurrence of small routine radionuclide releases. The analysis of accidental releases, however, indicated that the submarines should be located at a minimum distance of 2,5 km from inhabited areas in the coast of the Guanabara Bay. The need for environmental control and training of the teams involved in the attendance of the submarines, during the period of their visit, was also considered. The need for revising the procedures for the preoperational surveys to be performed at the

  12. Technology assessment HTR. Part 6. The radiological risks associated with the thorium-fuelled High Temperature Reactor. A comparative risk evaluation

    International Nuclear Information System (INIS)

    Dodd, D.H.; Van Hienen, J.F.A.

    1996-06-01

    This report presents the results of task B.3 of the 'Technology Assessment of the High Temperature Reactor' project. The objective of task B.3 was to evaluate the radiological risks to the general public associated with the sustainable HTGR cycle. Since the technologies to be used at several stages of this fuel cycle are still in the design phase and since a detailed specification of this fuel cycle has not yet been developed, the emphasis was on obtaining a global impression of the risk associated with a generic thorium-based HTGR fuel cycle. This impression was obtained by performing a comparative risk analysis on the basis of data given in the literature. As reference for the comparison a generic uranium fuel led LWR cycle was used. The structure of the report is as follows. In Chapter 2 the general methodology for assessing the radiological risks associated with nuclear installations is described. An overview is given of the measures commonly used to quantify these risks. In Chapter 3 an overview is given of the different stages of the reference uranium fuel led LWR cycle and the thorium fuel led HTGR cycle. In Chapter 4 a stage-by-stage analysis is given of the radiological risks associated with the two fuel cycles. Finally, in Chapter 5 an evaluation is made of the radiological risks associated with the LWR and HTGR cycles and with thorium and uranium fuels. In Appendix A the production and releases of 14 C for LWR and HTGR fuel cycle facilities is considered in detail. 11 figs., 10 tabs., 10 refs

  13. Influence Factors of Sports Bra Evaluation and Design Based on Large Size

    Directory of Open Access Journals (Sweden)

    Zhang Lingxi

    2016-01-01

    Full Text Available The purpose of this paper was to find the main influence factors of sports bra evaluation by the subjective assessment of different styles commercial sports bra, and to summarize the design elements of sports bra for large size. 10 women in large size (>C80 were chosen to evaluate 9 different sports bras. The main influence factors were extracted by factor analysis and all the product samples were classified by Q-cluster analysis. The conclusions show that breast stability, wearing comfort and bust modelling are the three key factors for sports bra evaluation. And a classification-positioning model of sports bra products was established. The findings can provide theoretical basis and guidance for the research and design of sports bras both for academic and sports or underwear enterprises, and also provide reference value for women customers.

  14. Comparison of toxicological and radiological aspects of K basins sludge

    International Nuclear Information System (INIS)

    RITTMANN, P.D.

    1999-01-01

    The composition of various K Basins sludge is evaluated for its toxicological and radiological impacts downwind from accidents. It is shown that the radiological risk evaluation guidelines are always more limiting than the toxicological risk evaluation guidelines

  15. Improving Genetic Evaluation of Litter Size Using a Single-step Model

    DEFF Research Database (Denmark)

    Guo, Xiangyu; Christensen, Ole Fredslund; Ostersen, Tage

    A recently developed single-step method allows genetic evaluation based on information from phenotypes, pedigree and markers simultaneously. This paper compared reliabilities of predicted breeding values obtained from single-step method and the traditional pedigree-based method for two litter size...... traits, total number of piglets born (TNB), and litter size at five days after birth (Ls 5) in Danish Landrace and Yorkshire pigs. The results showed that the single-step method combining phenotypic and genotypic information provided more accurate predictions than the pedigree-based method, not only...

  16. Reconstructive dosimetry and radiation doses evaluation of members of the public due to radiological accident in industrial radiography

    International Nuclear Information System (INIS)

    Lima, Camila Moreira Araujo de

    2016-01-01

    Radiological accidents have occurred mainly in the practices recognized as high risk radiological and classified by the IAEA as Categories 1 and 2, and highlighted the radiotherapy, industrial irradiators and industrial radiography. In Brazil, since there were five major cases in industrial radiography, which involved 7 radiation workers and 19 members of the public, causing localized radiation lesions on the hands and fingers. One of these accidents will be the focus of this work. In this accident, a "1"9"2Ir radioactive source was exposed for more than 8 hours in the workplace inside a company, exposing radiation workers, individuals of the public and people from the surrounding facilities, including children of a school. The radioactive source was also handled by a security worker causing severe radiation injuries in the hand and fingers. In this paper, the most relevant and used techniques of reconstructive dosimetry internationally are presented. To estimate the radiation doses received by exposed individuals in various scenarios of radiological accident in focus, the following computer codes were used: Visual Monte Carlo Dose Calculation (VMC), Virtual Environment for Radiological and Nuclear Accidents Simulation (AVSAR) and RADPRO Calculator. Through these codes some radiation doses were estimated, such as, 33.90 Gy in security worker's finger, 4.47 mSv in children in the school and 55 to 160 mSv for workers in the company during the whole day work. It is intended that this work will contribute to the improvement of dose reconstruction methodology for radiological accidents, having then more realist radiation doses. (author)

  17. The Evaluation Market in Germany: Estimating Market Size for Evaluation of Political Programs

    Science.gov (United States)

    Lowenbein, Oded

    2008-01-01

    The United States has a long tradition in evaluation of political programs. In the 1930s and 1940s, programs were initiated to reduce unemployment and improve social security as part of the "New Deal." In the late 1960s, somewhat comparable to the U. S. at that time, Germany's new government started its own "New Deal."…

  18. Radiological evaluation of the patency of duodenal-esophageal anastomosis during a long postoperative follow-up: effectiveness of an alkaline reflux model in rats

    Directory of Open Access Journals (Sweden)

    Cavazzola L

    2011-08-01

    Full Text Available André Vicente Bigolin1, João Vicente Grossi2, Juliano Hermes Maeso Montes1, Roberto Nicola1, Leandro Totti Cavazzola11School of Medicine, Lutheran University of Brazil, Canoas; 2Hospital de Pronto Socorro de Porto Alegre, Department of Surgery, Porto Alegre, Rio Grande do Sul, BrazilBackground: Performing experimental studies has played an important role in acquiring knowledge about esophageal carcinogenesis. In this context, the choice of a more reliable experimental model requires proof of its effectiveness in order to lend greater credibility to the results. The objective of this study was to evaluate the patency of duodenal-esophageal anastomosis during long-term postoperative follow-up in rats.Methods: This was an experimental study in which 45 female Wistar rats were used. A side-to-side anastomosis was performed, going from the anterior side of the esophagus to the second duodenal portion. A standardized radiological technique was used to carry out a contrasted radiological study of the esophagus, stomach, and duodenum during weeks 4, 12, 20, and 30 after surgery. Different contrast media were used, and the animals were divided into groups, ie, group 1 (100% barium sulfate, group 2 (50% barium sulfate, and group 3 (60% aqueous iodinated contrast media. Contrast radiographs were taken in each group at weeks 4, 12, 20, and 30 after the surgical procedure. The radiographic images were evaluated by two radiologists who were blinded regarding the contrast groups. Macroscopic evaluation of each animal was compared with the radiological findings.Results: Postoperative mortality was 13.33%. The remaining animals were divided into study groups. All the contrast radiological examinations showed evidence of the location of the esophagus, stomach, and proximal portion of the intestine, and demonstrated the laterolateral relationship of the distal esophagus and the duodenum in the epigastric region. Patency of the anastomosis was observed at each

  19. Children's estimates of food portion size: the development and evaluation of three portion size assessment tools for use with children.

    Science.gov (United States)

    Foster, E; Matthews, J N S; Lloyd, J; Marshall, L; Mathers, J C; Nelson, M; Barton, K L; Wried