WorldWideScience

Sample records for radiological equipment desenvolvimento

  1. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  2. Lack of security of networked medical equipment in radiology.

    Science.gov (United States)

    Moses, Vinu; Korah, Ipeson

    2015-02-01

    OBJECTIVE. There are few articles in the literature describing the security and safety aspects of networked medical equipment in radiology departments. Most radiologists are unaware of the security issues. We review the security of the networked medical equipment of a typical radiology department. MATERIALS AND METHODS. All networked medical equipment in a radiology department was scanned for vulnerabilities with a port scanner and a network vulnerability scanner, and the vulnerabilities were classified using the Common Vulnerability Scoring System. A network sniffer was used to capture and analyze traffic on the radiology network for exposure of confidential patient data. We reviewed the use of antivirus software and firewalls on the networked medical equipment. USB ports and CD and DVD drives in the networked medical equipment were tested to see whether they allowed unauthorized access. Implementation of the virtual private network (VPN) that vendors use to access the radiology network was reviewed. RESULTS. Most of the networked medical equipment in our radiology department used vulnerable software with open ports and services. Of the 144 items scanned, 64 (44%) had at least one critical vulnerability, and 119 (83%) had at least one high-risk vulnerability. Most equipment did not encrypt traffic and allowed capture of confidential patient data. Of the 144 items scanned, two (1%) used antivirus software and three (2%) had a firewall enabled. The USB ports were not secure on 49 of the 58 (84%) items with USB ports, and the CD or DVD drive was not secure on 17 of the 31 (55%) items with a CD or DVD drive. One of three vendors had an insecure implementation of VPN access. CONCLUSION. Radiologists and the medical industry need to urgently review and rectify the security issues in existing networked medical equipment. We hope that the results of our study and this article also raise awareness among radiologists about the security issues of networked medical equipment.

  3. Mission Analysis for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, Brooke R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wood-Zika, Annmarie R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haynes, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Klemic, Gladys A. [US Dept. of Homeland Security National Urban Security Technology Lab., Manhattan, NY (United States); Musolino, Stephen V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-01

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection (PRND) equipment to provide state and local agencies with scientific guidance on how to effectively use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed by technology manufacturers and purchased by responders for preventive detection and source interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management (CM) response take place, as it is currently the most widely available and fielded radiological instrumentation by state and local agencies. This effort will provide scientific guidance on the most effective way to utilize this class of equipment for consequence management missions. Gaining a better understanding of how PRND equipment can operate and perform for these missions will allow for recommendations on the tactical approach responders can use for consequence management operations. PRND equipment has been placed into service by federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be leveraged to support the emergency response in the aftermath of a radiological or nuclear event. With several hundred makes and models of PRND equipment, often with significantly different detection capabilities that do not align with their nominal PRND equipment type, development of a streamlined categorization scheme with respect to consequence management missions was the first step to identifying safe and effective uses of PRND equipment for radiological/nuclear incident response.

  4. Estimation of dose challenge in radiological exams policontuses patients in public hospital in Santiago with digital radiology equipment

    International Nuclear Information System (INIS)

    Diaz-Munoz Ihmaidan, Gabriela

    2012-01-01

    lonizing radiation is always present in our natural environment and with the development of new technologies in diagnostic radiology we have elevated the exposure to radiation with an increased dose to both patient and professionals. This is of great importance for secondary stochastic effects that could be generated by exposure to ionizing radiation. There are different x-ray entrance dose studies in patients with radiological examinations in conventional radiology equipment, but not in trauma patients examinated with digital radiology equipment where there is a supposed greater exposure to radiation because of the increase of the number of radiological examinations requested. This study determined the doses received by trauma patients in a direct digital x ray equipment (in a ER in Santiago, Chile) and see if the doses are within the ones recommended by international societies. We used thermoluminescent crystals which were first properly calibrated and located in the center of the radiation beam. The results obtained show that using good practice we can obtain acceptable dose levels, independently of the digital equipment used where it is presumed that could give a higher dose of ionizing radiation exposure than conventional x-ray equipment

  5. Radiological equipment 'Planmeca' used in dentistry

    International Nuclear Information System (INIS)

    Tuciac, Carolina

    2011-01-01

    Equipment 'Planmeca Pro Max 3D' for volumetric imaging with cone beam examine the patients under computerized tomography considering the rate 0.2-1.0 mm, digital orthopantomography, 3D cephalometry. 3D tomography image facilitates an accurate view of oral structures. It was adopted quickly, and became the basic equipment for all applications in dentistry. The Cone Beam Volumetric Tomography (CBVT), Planmeca Pro Max 3D model give the opportunity to obtain great radiological information very important for the dentist decision. (author)

  6. Gerenciando equipes de design interna e externa no processo de desenvolvimento de produtos: caso de duas empresas calçadistas do sul do Brasil.

    Directory of Open Access Journals (Sweden)

    Andréa Capra

    2012-12-01

    Full Text Available Esse artigo trata da inserção do design no processo de desenvolvimento de produtos em duas empresas da indústria calçadista da região do Vale do Paranhana, no Rio Grande do Sul. Essas empresas podem trabalhar com diferentes tipos de equipes, interna, externa ou mista e, entender as vantagens e desvantagens de cada tipo de equipe é fundamental ao determinar a melhor opção para a empresa. Porém, pouco tem-se estudado buscando essa relação entre equipes de design e desenvolvimento de produtos. Nesse sentido, o objetivo do estudo foi analisar o gerenciamento de equipes de design, interna e externa, no processo de desenvolvimento de produtos de empresas da indústria calçadista. Para isso, um estudo de caso foi realizado através da análise do caso de uma empresa que trabalhava com os dois tipos de equipes. Com a realização desta pesquisa, foi possível estudar a forma de atuação e gerenciamento das equipes interna e externa de design no processo de desenvolvimento de produtos. Os resultados indicam que diferenças nas formas de atuação e gerenciamento de cada equipe estão relacionados com a autonomia decisória conferida para equipe no início do desenvolvimento de novos projetos.

  7. Job Aids for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, Brooke R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haynes, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wood-Zika, Annmarie R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Klemic, Gladys [US Department of Homeland Security National Urban

    2017-10-02

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation.

  8. Radiologic Equipment and Technicians according to the Distribution of the Population

    International Nuclear Information System (INIS)

    Yoon, Chul Ho; Choi, Jun Gu

    2009-01-01

    The purpose of this paper is to provide basic data in order to systematize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipment and technicians according to the distribution of the population. We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without 'Gu' administrative units in 2008. 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipment to radiologic technicians is 2.6 to 1. There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  9. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  10. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  11. US DOE Radiological Assistance Program: personnel, equipment and resources

    International Nuclear Information System (INIS)

    Hull, A.P.; Kuehner, A.V.; Phillips, L.F.

    1982-01-01

    The Radiological Assistance Program (RAP) of the US Department of Energy (DOE) is intended to provide emergency advice and assistance in the event of radiological incidents. Each of DOE's eight Regional Coordinating Offices in the US provide a 24-hour reporting and response capability. Specifically, the Brookhaven Area Office (BHO) is responsible for DOE's Region I, which includes the 11 northeastern states of the US. Although an inventory of dedicated equipment is assigned to BHO-RAP, it draws upon the resources of Brookhaven National Laboratory (BNL) for trained personnel in health physics and for other specialized personnel in both the day to day operation of the program and in the on-the-scene response to an incident. The organization of the BHO-RAP program and its response procedures are described in detail. An inventory and brief description of the contents of a variety of emergency equipment kits and of additional state-of-the-art instruments is included. The BHO-RAP guidelines and requirements for field operations are also indicated, as are other DOE resources upon which it can draw

  12. Functional integration of digital radiologic equipment

    International Nuclear Information System (INIS)

    Agnifili, A.; DiStefano, G.; Salcito, G.; Passariello, R.

    1989-01-01

    This paper reports on a pilot project for the functional integration of digital radiologic equipment. Four different systems (a digital subtraction angiography unit, a DF unit, a computer radiography prototype, and a film digitizer) were connected with a link in an Ethernet LAN.ACR-NEMA standards were used to process the images of the different units in the same way. The central computer manages the long-term optical archive and the film laser printer. Some graphic workstations are connected to the picture archiving and communications system, which allows fast retrieval and processing of the images. Patients; data are acquired through the RIS and stored together with the images

  13. Guidelines for Quality Control of Equipment Used in Diagnostic Radiology in the Netherlands

    International Nuclear Information System (INIS)

    Berg, L. van den; Aarts, C.N.M.; Beentjes, L.B.; Dalen, A. van; Elsakkers, P.; Julius, H.W.; Kicken, P.J.H.; Meer, F. van der; Teeuwisse, W.; Thijssen, M.A.O.; Zoetelief, J.

    1998-01-01

    The Dutch working group on 'Quality Criteria for Equipment Used in Diagnostic Radiology' has formulated guidelines providing technical criteria for equipment used in conventional diagnostic radiology. These guidelines are applicable to the technical parameters having a major impact on image quality and patient dose and include methods for testing. The following parameters are included: tube voltage, automatic exposure control, film processing, film-screen combination, light tightness and illumination of the dark room, half-value layer and filtration, light field, grid, focal spot size, viewing boxes and geometrical indicators. Each guideline consists of the following chapters: (1) Scope and field of application, (2) Background information, (3) Test procedure, (4) Test frequency, (5) Registration of observations, (6) Evaluation and interpretation, (7) Test report. Chapter 3 includes both the principles of the test method and a step by step description of the procedures. The principles of the test procedure provide a basis for adaptation to local circumstances. The step by step test procedure allows a quality control measurement to be performed with limited physical knowledge of the equipment. Chapter 6 includes limiting values. Draft guidelines were evaluated in practice in 20 hospitals. The final document has been accepted by the professional societies in the Netherlands and the Dutch Minister of Health as a reference set of tools to perform Quality Control of equipment used for conventional diagnostic radiology. (author)

  14. Radiology equipment maintenance and contract procurement in the UK.

    Science.gov (United States)

    Wright, Christopher J

    2012-01-01

    Radiology equipment maintenance has a similar financial value to new device acquisition over the lifetime of the device. Comprehensive style contracts are dominant largely due to their ease of use and the potential to control budgetary costs, but costs are high. Creative procurement solutions can offer better value. The corrective portion of comprehensive contracts is estimated to be between 50% (Mobile C-Arm) to 92% (CT), which equates to $29.4 million; 80% of the total contract costs within the research population of this study. Many organizations could free up cash by better managing their maintenance costs, potentially creating funding opportunities for new equipment.

  15. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dong Hee; KIm, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

  16. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    International Nuclear Information System (INIS)

    Hong, Dong Hee; KIm, Hyeong Gyun

    2016-01-01

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test

  17. Rede social de apoio ao desenvolvimento infantil segundo a equipe de saúde da família

    Directory of Open Access Journals (Sweden)

    Ana Paula Dezoti

    2013-09-01

    Full Text Available O objetivo deste estudo foi identificar as redes sociais de apoio às famílias para a promoção do desenvolvimento infantil na perspectiva da equipe Estratégia Saúde da Família. MÉTODOS: Pesquisa qualitativa descritiva. Foram sujeitos doze profissionais de saúde, sendo três de cada categoria profissional: enfermeiro, médico, auxiliar de enfermagem e agente comunitário de saúde que atuam nas unidades de saúde do estudo. Os dados foram coletados por meio de entrevista semiestruturada e analisados segundo análise categorial temática. RESULTADOS: Os resultados evidenciaram três categorias empíricas: Elementos da rede social de apoio; Funções de apoio às famílias; Dificuldades e lacunas na rede social de apoio às famílias. CONCLUSÃO: Considera-se que as redes sociais têm importante papel na vinculação das famílias, fortalecendo seu potencial para o desenvolvimento infantil saudável. Recomenda-se que os profissionais de saúde articulem ações que possam influenciar esses elementos de maneira que promovam o desenvolvimento infantil adequado.

  18. Management of radiological related equipments. Creating the equipment management database and analysis of the repair and maintenance records

    International Nuclear Information System (INIS)

    Eguchi, Megumu; Taguchi, Keiichi; Oota, Takashi; Kajiwara, Hiroki; Ono, Kiyotune; Hagio, Kiyofumi; Uesugi, Ekizo; Kajishima, Tetuo; Ueda, Kenji

    2002-01-01

    In 1997, we established the committee of equipments maintenance and management in our department. We designed the database in order to classify and register all the radiological related equipments using Microsoft Access. The management of conditions and cost of each equipment has become easier, by keeping and recording the database in the equipments management ledger and by filing the history of repairs or maintenances occurred to modalities. We then accounted numbers, cost of repairs and downtimes from the data of the repair and maintenance records for four years, and we reexamined the causal analysis of failures and the contents of the regular maintenance for CT and MRI equipments that had shown the higher numbers of repairs. Consequently, we have found the improvement of registration method of the data and the more economical way to use of the cost of repair. (author)

  19. Radiation protection problems with dental radiological equipment

    International Nuclear Information System (INIS)

    Cooney, P.; Rajan, J.; Malone, J.F.; Gavin, G.

    1995-01-01

    With the advent of the EC Patient Directive, the importance of surveying and optimising patient exposure for diagnostic imaging procedures is paramount. In the field of dentistry there has been a heightened interest in areas of equipment performance and patient exposure. This interest, coupled with a number of dental radiation safety incidents investigated by our department, and the issuing of a Code of Practice for Radiological Protection in Dentistry by the Department of Health, led to the establishment in our department, of an evaluation protocol for the performance and operation of dental X ray equipment. The protocol was used to perform a survey on over 100 dental X ray units in use in the Public Sector in Ireland. This presentation will report on the radiation incidents mentioned above. It will detail the protocol and furnish the results and conclusions of the survey. The survey has made it possible to establish clearly the necessary steps required to ensure compliance with requirements. In addition, the corrective steps taken by the dental authorities will be presented and the overall impact of the regulations and the programme consequent on them will be reviewed. (Author)

  20. The study on the perceptions of radiological technologist in medical imaging equipment used by the oriental doctor

    International Nuclear Information System (INIS)

    Choi, Jae Ho; Kang, Gi Bong; Kim, Sang Hyun

    2017-01-01

    In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20∼30s, neutral in the 40∼50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future

  1. The study on the perceptions of radiological technologist in medical imaging equipment used by the oriental doctor

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Ho [Dept. of Radiological Technology, Ansan University, Ansan (Korea, Republic of); Kang, Gi Bong [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Sang Hyun [Dept. of Radiology, Shinhan University, Seongnam (Korea, Republic of); and others

    2017-03-15

    In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20∼30s, neutral in the 40∼50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

  2. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  3. Tool for the verification of geometrical parameters and constancy of image quality in radiology equipment

    International Nuclear Information System (INIS)

    Mayo, P.; Verdu Martin, G.; Rodenas Escriba, F.; Marin Peinado, B.; Camapyo Esteban Nogueira, J. M.; Diez Domingo, S.; Villaescusa Blanca, J. I.; Hernando Gonzalez, I.; Ruiz Manzano, P.; Rivas Ballarin, M. A.; Melcho Iniguez, M.; Asensio Martinez, M. I.

    2013-01-01

    This paper presents the application of an innovative tool developed for the detailed quality control of diagnostic equipment. We have tried to validate such a tool for verification of geometrical parameters and the evaluation of the constancy of the image quality in radiology equipment, evaluating their usefulness by various services of Radio physics and radiation protection of different hospitals. (Author)

  4. Obesity in Ireland in 2008: what radiological equipment is available to image the obese patient?

    LENUS (Irish Health Repository)

    Campbell, N

    2009-04-01

    Obesity is a global epidemic, responsible for 2000 premature deaths in Ireland each year. The extent of this epidemic was quantified by the National Taskforce on Obesity (IOTF), whose report, published in 2005, found that 39% of adults in Ireland were overweight and 18% obese with obesity in adults predicted to increase by 1% per year. In light of the clear evidence that we, as a nation, are quite literally expanding, how well equipped are Irish hospitals and, in particular, radiology departments, to deal with patients of increasing size and weight? The purpose of this study was to quantify the weight limits and girth restrictions of the radiology equipment, in particular CT, MRI and fluoroscopy, in hospitals, both public and private, in Ireland in an attempt to answer this question.

  5. Desenvolvimento de um ambiente virtual para o ensino da medicina por uma equipe multidisciplinar: fatores que influenciam a análise do problema educativo

    Directory of Open Access Journals (Sweden)

    Paula Ramos

    2010-12-01

    Full Text Available Este estudo investigou a fase de análise do problema educativo no processo de pesquisa e desenvolvimento de um ambiente virtual para ensino de Medicina, apoiado na metodologia da Pesquisa Baseada em Design. A equipe multidisciplinar, composta por pesquisadores de tecnologia educacional e saúde, discutiu o problema da formação tecnicista e a necessidade de enfatizar experiências subjetivas dos pacientes sobre o adoecimento e tratamento, como forma de incluir valores éticos na formação. Com base na análise de conteúdo das transcrições das reuniões da equipe, discutiram-se os aspectos que influenciaram a negociação para definição do problema educativo, dos objetivos do ambiente e da teoria norteadora do seu desenvolvimento. Concluiu-se que, na análise de problemas complexos, como os da saúde, é fundamental a integração das crenças epistemológicas - sobre formação em saúde, saúde e tecnologia educacional - e dos saberes docentes experienciais e disciplinares.

  6. X ray spectra and qualities for use in diagnostic radiology and equipment calibration

    International Nuclear Information System (INIS)

    Souza, Karla Cristina de

    1996-12-01

    The goal of this work was the standardization of radiation qualities of diagnostic X ray equipment of the Assay Laboratory of the Institute for Radiation Protection and Dosimetry (IRD) of the National Commission of Nuclear Energy, Brazil. X ray spectra were determined from pulse height distribution measured directly on the primary beam using a high pure planar Ge detector. A program was developed to convert pulse height distribution into radiation spectra in the range from 20 to 150 keV. X ray qualities based on those used by the 'Physikalish-Technish Bundesantalt' (PTB) primary laboratory were implanted in three radiological equipment of the Assay Laboratory. These qualities simulate radiation beams on patients submitted to typical radiological examinations. Besides the spectrometric system, a reference measurement system based on an ionization chamber calibrated in air kerma was used to establish parameters such as kilovoltage, first and second half-value layer, mean energy, effective energy and inherent filtration. Our data have shown that the implantation of these radiation qualities in the Assay Laboratory results on a metrological basis for calibration of dose measurement assemblies and kV-meters, like those used by IRD to evaluate the parameters of X ray equipment around the country. A catalogue of spectral data resulting from this work is a data bank that allows various applications like dose calculation using Monte Carlo simulation techniques. (author)

  7. Radiology preparedness in ebola virus disease: guidelines and challenges for disinfection of medical imaging equipment for the protection of staff and patients.

    Science.gov (United States)

    Mollura, Daniel J; Palmore, Tara N; Folio, Les R; Bluemke, David A

    2015-05-01

    The overlap of early Ebola virus disease (EVD) symptoms (eg, fever, headache, abdominal pain, diarrhea, emesis, and fatigue) with symptoms of other more common travel-related diseases (eg, malaria, typhoid fever, pneumonia, and meningococcemia) may result in delayed diagnosis of EVD before isolation of infected patients. Radiology departments should consider policies for and approaches to decontamination of expensive and potentially easily damaged radiology equipment. In addition, the protection of radiology personnel must be considered during the work-up phase of undiagnosed EVD patients presenting to emergency departments. The purpose of this article is to consider the effect of EVD on radiology departments and imaging equipment, with particular consideration of guidelines currently available from the Centers for Disease Control and Prevention that may be applicable to radiology. (©) RSNA, 2015.

  8. Analysis of a radiation incident with intraoral dental radiological equipment

    International Nuclear Information System (INIS)

    Malone, J.F.

    1996-01-01

    A case is described involving a serious incident with dental radiological equipment, containing many lessons that may be applied to the preparation of other cases. The description includes an account of the incident, the circumstances surrounding it, the dosimetry, risk estimates and the medical consequences of the incident. In addition, some aspects of the associated legal proceedings are reviewed and assessed. As a result of the incident described, a number of conclusions are drawn with respect to important practices in ensuring the safety of installations and the value of evidence brought forward by expert witnesses. (author)

  9. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    Science.gov (United States)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  10. Application of Oversampling to obtain the MTF of Digital Radiology Equipment

    International Nuclear Information System (INIS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-01-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment. (paper)

  11. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  12. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  13. Radiological security of portable equipment used in the industry

    International Nuclear Information System (INIS)

    Cateriano, M.A.

    2006-01-01

    The industrial meters with encapsulated sources are used intensely in the present time due to the economic benefits that generate. Their use in all the one world has been reflected in an improvement of the quality of the analyzed product and of one optimization of the production process, allowing to carry out these measurements and controls without interrupting the process and in non destructive form generating an energy saving in turn and of materials. Although these industrial meters are intrinsically safe for design in the portable meters their safety also is strongly governed in the strict pursuit of procedures and in the adequate personnel's training that operate these equipment. In the Argentine Republic in 2005 the Nuclear Regulatory Authority (RNA) had registered a quantity of 160 portable equipment. In the period 1995-2003, 2 incidents took place with these equipment one of them used to measure soils humidity of Troxler trademark containing a source of Am-241(Be) of 370 MBq and the remaining one also of Troxler trademark used to measure density and humidity of soils containing 2 sources of Cs-137 of 296 MBq and Am-241(Be) of 1.48 GBq respectively. The incidents were developed without relevant radiological implications had taken place. In this work those mentioned incidents are analyzed in order to determining the causes that originated the same ones, for this way to be able to elaborate recommendations with the purpose of to correct errors and to diminish the recurrence probability improving the safety in the use of these equipment. From the analyses of these incidents result that should put on more emphasis in the personnel training and the invigoration of the safety culture in the use of the industrial meters. Also a present panorama of the inventory of equipment, sources and users that possess these portable meters in the Argentine Republic is also presented. (Author)

  14. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  15. Desenvolvimento de um ambiente virtual para o ensino da medicina por uma equipe multidisciplinar: fatores que influenciam a análise do problema educativo

    OpenAIRE

    Paula Ramos; Miriam Struchiner

    2010-01-01

    Este estudo investigou a fase de análise do problema educativo no processo de pesquisa e desenvolvimento de um ambiente virtual para ensino de Medicina, apoiado na metodologia da Pesquisa Baseada em Design. A equipe multidisciplinar, composta por pesquisadores de tecnologia educacional e saúde, discutiu o problema da formação tecnicista e a necessidade de enfatizar experiências subjetivas dos pacientes sobre o adoecimento e tratamento, como forma de incluir valores éticos na formação. Com bas...

  16. Military radiology during the first world conflict

    International Nuclear Information System (INIS)

    Le Vot, J.

    2016-01-01

    Published at the occasion of the centenary of the First World War, this article proposes an historical overview of the emergence and development of military medical radiology during this conflict. The author first describes the situation of radiology in the different armies and countries on the eve of the war as this application of radiology is relatively recent (it is based on Roentgen's discovery in 1895). He indicates the first steps of emergence of radiology department in military hospitals, the interest of military physicians in radiology and the availability of mobile equipment which had been actually presented at the parade on the 14 July 1914. The author then highlights some important personalities who have been important actors of the development, application and use of radiology and of military radiology during the war. He proposes an overview of radiological equipment in 1914, of the variety of vehicles adapted to transport and use such equipment. He also comments how radiology professionals were trained

  17. Radiological diagnosis of stomach cancer

    Energy Technology Data Exchange (ETDEWEB)

    Horlacher, B

    1981-05-01

    The problems of routine radiology and the differential diagnosis of malignant and benign gastric ulcers are gone into. The value of endoscopy combined with radiology is stressed. The patient, the physician, and the X-ray equipment have to meet certain requirements in order to obtain good images and make a correct interpretation. The most important aspect of radiology today is radiation protection, which is possible only with efficient equipment and experienced medical examiners.

  18. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  19. Protective equipment of radiological protection and the worker wear

    International Nuclear Information System (INIS)

    Cassia, Flor Rita de; Huhn, Andrea; Lima, Gelbcke Francine

    2013-01-01

    This qualitative research with workers of seven hemodynamic service of Santa Catarina, Brazil aimed to analyze the use of radiological protection equipment (RPE), as well as wear to the health of workers who use these causes. The study was conducted between March 2010 and November 2010, totaling approximately 30 hours of observations. Results showed resistance to the use of RPE and also showed wear to workers' health, mainly due to the weight and discomfort they cause, as may weigh 7-9 pounds, depending on the model used. Evidenced also the absence of workers due herniated disc, back pain, and other musculo skeletal problems. These complaints, in addition to being related to the use of these protective gear also related with the time that workers remain standing for long periods on certain procedures, such as angioplasty. Given these results, the research recommended the use of these devices with materials, that are already being produced, making lighter aprons, thus avoiding fatigue and back pain and also provide greater comfort by reducing workers' resistance to its use and its adverse consequences

  20. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  1. Modelo de gerenciamento da manutenção de equipamentos de radiologia convencional Maintenance management model for conventional radiology equipments

    Directory of Open Access Journals (Sweden)

    Nelson Fraga do Couto

    2003-12-01

    Full Text Available Foi elaborado um modelo de gerenciamento da manutenção dos equipamentos convencionais de raios X no Hospital Universitário Clementino Fraga Filho. O modelo foi implementado em várias etapas, que incluíram visitas a centros hospitalares que gerenciam seus equipamentos, linha de colaboração com a Fundação Oswaldo Cruz para realização de cursos e treinamento de técnicos de eletrônica do hospital, montagem de uma esquemateca dos equipamentos em uso, criação de um programa de gerenciamento utilizando um banco de dados na plataforma Microsoft Windows 98-Access, levantamento operacional e condições de funcionamento dos equipamentos. A criação de uma nova rotina nas manutenções vai ao encontro das necessidades de reduzir o tempo de atendimento, custos, e de melhoria na qualidade da imagem em um serviço de radiodiagnóstico, atendendo também às exigências da Portaria 453/98 do Ministério da Saúde.We developed a management model for maintenance of hospital radiological X-ray equipment. The model was implemented in several steps including visits to other hospitals where equipment management is also done, collaboration work with "Fundação Oswaldo Cruz" for the realization of courses and a training program for the hospital electronic technicians, organization of a small library with the schemes of the radiological equipment in use at "Hospital Universitário Clementino Fraga Filho", Rio de Janeiro, Brazil, development of a management software using a database from Access (Microsoft Windows and evaluation of the performance of the radiological equipment. The implementation of a new routine for equipment maintenance fulfils the need for reducing repair delay and costs, improving image quality in radiodiagnosis services, and complying with resolution 453/98 of the Brazilian Ministry of Health.

  2. Bismuth Infusion of ABS Enables Additive Manufacturing of Complex Radiological Phantoms and Shielding Equipment

    Directory of Open Access Journals (Sweden)

    Justin Ceh

    2017-02-01

    Full Text Available Radiopacity is a critical property of materials that are used for a range of radiological applications, including the development of phantom devices that emulate the radiodensity of native tissues and the production of protective equipment for personnel handling radioactive materials. Three-dimensional (3D printing is a fabrication platform that is well suited to creating complex anatomical replicas or custom labware to accomplish these radiological purposes. We created and tested multiple ABS (Acrylonitrile butadiene styrene filaments infused with varied concentrations of bismuth (1.2–2.7 g/cm3, a radiopaque metal that is compatible with plastic infusion, to address the poor gamma radiation attenuation of many mainstream 3D printing materials. X-ray computed tomography (CT experiments of these filaments indicated that a density of 1.2 g/cm3 of bismuth-infused ABS emulates bone radiopacity during X-ray CT imaging on preclinical and clinical scanners. ABS-bismuth filaments along with ABS were 3D printed to create an embedded human nasocranial anatomical phantom that mimicked radiological properties of native bone and soft tissue. Increasing the bismuth content in the filaments to 2.7 g/cm3 created a stable material that could attenuate 50% of 99mTechnetium gamma emission when printed with a 2.0 mm wall thickness. A shielded test tube rack was printed to attenuate source radiation as a protective measure for lab personnel. We demonstrated the utility of novel filaments to serve multiple radiological purposes, including the creation of anthropomorphic phantoms and safety labware, by tuning the level of radiation attenuation through material customization.

  3. Safety aspects in radiology

    International Nuclear Information System (INIS)

    Silva, D.C. da.

    1991-05-01

    The development of a program for the evaluation of the physical installations and operational procedures in diagnostic radiology with respect to radiation-safety is described. In addition, a proposal for the quality analysis of X-ray equipment and film-processing is presented. The purpose is both to ensure quality and safety of the radiology service, as well as to aid in the initial and in-service training of the staff. Interviews with patients, staff practicing radiology at a wide range of levels and the controlling authorities were carried out in the State of Rio de Janeiro in order to investigate the existence and the effective use of personal radioprotection equipment as well as user's and staff's concern for radiation safety. Additionally physical measurements were carried out in University Hospitals in Rio de Janeiro to assess the quality of equipment in day-to-day use. It was found that in the locations which did not have routine maintenance the equipment was generally in a poor state which lead to a high incidence of repetition of examinations and the consequent financial loss. (author)

  4. Occupational exposure in interventional radiology

    International Nuclear Information System (INIS)

    Oh, H.J.; Lee, K.Y.; Cha, S.H.; Kang, Y.K.; Kim, H.J.; Oh, H.J.

    2003-01-01

    This study was conducted to survey of radiation safety control and to measure occupational radiation exposure dose of staff in interventional radiology in Korea. Interventioanl radiology requires the operator and assisting personnel to remain close to the patient, and thus close to primary beams of radiation. Therefore exposure doses of these personnel are significant from a radiological protection point of view. We surveyed the status of radiation safety on interventional radiology of 72 hospitals. The result were that 119 radiation equipments are using in interventional radiology and 744 staffs are composed of 307 radiologists, 116 residents of radiology, 5 general physicians, 171 radiologic technologists and 145 nurses. 81.4% and 20.2 % of operating physicians are using neck collar protector and goggle respectively. The average radiation dose was measured 0.46±0.15 mSv/10 hours fluoroscopy inside examination room in radiation protection facilities. Occupational radiation exposure data on the staff were assessed in interventional radiology procedures from 8 interventional radiology equipments of 6 university hospitals. The dose measurements were made by placing a thermoluminesent dosimeter(TLD) on various body surface of operation and assistant staff during actual interventional radiology. The measured points were the corner of the eyes, neck(on the thyroid) , wrists, chest(outside and inside of the protector), and back. Average radiation equivalent dose of the corner of left eye and left wrist of operating physicians were 1.19 mSv(0.11∼4.13 mSv)/100 minutes fluoroscopy and 4.32 mSv(0.16∼11.0 mSv)/100 minutes fluoroscopy respectively. Average exposure dose may vary depending on the type of procedure, personal skills and the quality of equipment. These results will be contributed to prepare the guide line in interventional radiology in Korea

  5. Cost accounting of radiological examinations. Cost analysis of radiological examinations of intermediate referral hospitals and general practice.

    Science.gov (United States)

    Lääperi, A L

    1996-01-01

    The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and

  6. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed.

  7. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    International Nuclear Information System (INIS)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed

  8. Attention for pediatric interventional radiology

    International Nuclear Information System (INIS)

    Zhu Ming; Cheng Yongde

    2005-01-01

    Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae

  9. Development of radiology in Mongolia

    International Nuclear Information System (INIS)

    Gonchigsuren, D.; Munkhbaatar, D.; Tuvshinjargal, D.; Onkhuudai, P.

    2007-01-01

    Full text: Radiology had been introduced in Mongolia by the establishment of the first X-Ray room at the First State Central Hospital in 1934. First radiologists in Mongolia were invited from the former Soviet Union; V. Sokolov, P. Omelchenko and others worked at the ''Burevestnik'' X-ray equipment of Russian production with high X-ray exposure and low capacity; they could perform only limited arts of Xray studies like fluoroscopy of thorax, stomach, esophagus and roentgenography of skull and extremities. The second X- ray equipment has been presented by the close friend of Lenin, the Director of People's Commissariat of Health Protection of the Soviet Union, Dr. N.A. Semashko; the present had been dedicated to the 10th Anniversary of Mongolian Health Care sector. During the military maneuvers at Khalkhin- Gol in 1939, several province hospitals and military hospitals had been supplied by the Xray equipment. During the period 1959-1960 all province hospitals, specialized hospitals had got X-ray unit. In 1955, Radii 226 had been used at first time in Mongolia for a treatment. In 1959, the State Radiological Clinic had been founded as a branch of X-ray cabinet of the First State Central Hospital. By the initiative of the absolvent of University of Leipzig, German Democratic Republic, Dr. P. Onkhuudai, Laboratory of Nuclear Medicine was established on 31 PstP March 1975 at the First State Central Hospital, which performed urography, thyroid and liver studies using Iod-131, Au-198, Hg-203 isotopes. In 1982, the gamma-camera and radio immunological equipment had been donated by the World Health Organization, and the Laboratory of Nuclear Medicine had been reorganized into Department of Nuclear Laboratory. Afterwards, in 1992 CT and SPECT diagnostics had been introduced at the First State Central Hospital, therefore new possibilities for high quality radiological diagnostic in Mongolia had been created. In 2007 the Siemens Magnetom 0.3 Tesla had been installed at the

  10. Evaluation of the conditions of operation of X-ray equipment as regards the coincidence between light field, radiation field and the central ray alignment in radiology services of the Recife, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Claudia F.M.; Silva, Iran J.O.; Lopes Filho, Ferdinand J.; Morais, Carolinne S.; Junior, Claudio L.R.

    2014-01-01

    This paper aims at considering the need for constant evaluation of diagnostic radiology equipment and the fact that this issue be part of the radiology technologist's tasks, develop skills in radiology technologist through applying quality control tests, as regards the assessment of coincidence between the light field and the radiation field and the alignment of the radiation beam of medical X-ray equipment in radiology services in the city of Recife. For the tests, the procedures by national protocols of Quality Control Tests were adopted - QCT and the Medical Radiodiagnosis Manual. The instruments used to check the alignment of the central ray was an acrylic cylinder with steel balls of 0.8 mm diameter located in the upper and lower base separated by a distance of 15 cm, a chassis loaded with film, tape and level bubble. The results show that the tested devices are in good condition for diagnostic radiology, with regard to both the radiation field to be exposed as well as the image quality for a more accurate diagnosis, which guarantees the individual radiological protection

  11. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  12. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil

    International Nuclear Information System (INIS)

    Passos, Robson Silva

    1999-05-01

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than ± 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than ± 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m 2 . Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment presented

  13. ESTRATÉGIA DO DESENVOLVIMENTO URBANO COMO FATOR DETERMINANTE PARA O DESENVOLVIMENTO INDUSTRIAL SUSTENTÁVEL

    Directory of Open Access Journals (Sweden)

    Rúbia Tânia Welter

    2016-11-01

    Full Text Available Este artigo tem por objetivo identificar a estratégia do desenvolvimento urbano como fator do desenvolvimento industrial sustentável. Para alcançar este objetivo, foi realizada uma pesquisa documental e uma revisão histórico-bibliográfica de uma cidade, neste caso, a cidade de Joinville-SC. Foi realizado, também, um estudo sobre a evolução dos acontecimentos históricos da cidade pesquisada, como forma de estabelecer que estratégias adotadas interferiram neste processo de desenvolvimento. Como resultado, foram identificados os fatores estratégicos inerentes ou determinantes para o desenvolvimento industrial da cidade. Palavras-chave: Desenvolvimento urbano. Desenvolvimento industrial. Fatores estratégicos.

  14. Evaluation of radiological protection aspects in radiodiagnostic rooms in Mexico City

    International Nuclear Information System (INIS)

    Escobar A, L.; Vizuet G, J.; Ruiz, M.A.

    1996-01-01

    The preliminary results of an evaluation of radiological protection carried out in radiology services of different hospitals of Mexico are shown. The evaluated points were: relative aspects of the room, operation parameters of operation of the equipment, work procedures and training about radiological protection for the equipment operators. (authors). 2 refs., 1 fig

  15. The Pathology of Infection in the Department of Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Radiology, Dong a University Medical Center, Pusan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Nuclear Medicine, Pusan National University Hospital, Pusan (Korea, Republic of)

    2012-09-15

    This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

  16. The Pathology of Infection in the Department of Radiology

    International Nuclear Information System (INIS)

    Shin, Seong Gyu; Lee, Hyo Yeong

    2012-01-01

    This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

  17. Emerging new modalities in dental radiology and radiation issues

    International Nuclear Information System (INIS)

    Gandhi, Rahul

    2014-01-01

    Dental radiology is emerging day by day with technological innovations and new dental radiological equipments. These sophisticated new emerging technological raise a concern about the radiation emitted by these equipments. This becomes more relevant in the context that there is frequent diagnostic radiographic exposure of head and neck region due to recurrent dental problems. The presentation deals with radiation exposure to the patients and professionals from these equipments. (author)

  18. Aprimorando a Gerência e o Desenvolvimento de Software com Metodologias Ágeis

    Directory of Open Access Journals (Sweden)

    Mauricio Andreazza Sganderla

    2016-07-01

    Full Text Available Este artigo aborda a melhoria da gerência e construção de software utilizando as metodologias ágeis eXtreme Programming e Scrum. São aplicadas as melhores práticas de ambas as metodologias em uma equipe de desenvolvimento de software, em um ambiente em que não havia nenhum processo bem definido de desenvolvimento de software. A escolha pelo uso das metodologias ágeis foi definida, pois atende ao dinamismo do cenário atual, requisitos voláteis, ambiente mais colaborativo e menos burocrático, tendo como objetivo principal o software em funcionamento e que realmente traga retorno ao cliente.

  19. Preventive Rad/Nuc Detection Equipment Categorization for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, B. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Musolino, S. V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Klemic, G. [US Dept. of Homeland Security National Security Technology Lab., New York, NY (United States)

    2017-06-01

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection equipment (PRND) to provide state and local agencies with guidance on how to best use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed for detection and interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management response take place. This effort will provide scientific guidance on the best way to deploy and operate this class of equipment for consequence management missions. With the support of the US Department of Homeland Security’s (DHS) Domestic Nuclear Detection Office (DNDO), PRND equipment has been placed into service at federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be repurposed to support the emergency response in the aftermath of a radiological of nuclear event. This report evaluates PRND equipment to define key categories of equipment and the types of missions they can be used for. This is important because there are over 100 different types of PRND equipment, often with significantly different capabilities with respect to the consequence management mission. The current DNDO draft NIMS PRND equipment types were used as a foundation and expanded, when necessary, to address key characteristics important for the consequence mission. Table 1 provides a summary of the PRND instrument categories developed for this effort. Also included on the table are some common response mission detection equipment categories that will be used for capability comparisons.

  20. An Overview of Dental Radiology. NCHCT Monograph Series.

    Science.gov (United States)

    Manny, Edward F.; And Others

    This overview of dental radiology contains sections on demographics, equipment, dental radiology quality assurance, efficacy, dental radiology education curricula, professional organizations' guidelines for training and use, and state activities. In section 1 dental personnel, population of dental personnel, employment and earning prospects,…

  1. Avaliação do crescimento e desenvolvimento de crianças institucionalizadas

    Directory of Open Access Journals (Sweden)

    Caroline Magna Pessoa Chaves

    2013-10-01

    Full Text Available O estudo objetivou avaliar o crescimento e desenvolvimento de crianças de 0 a 6 anos institucionalizadas. Abordagem descritiva, transversal e de natureza quantitativa. Foi realizado em um abrigo da Secretaria do Trabalho e Desenvolvimento Social do Governo do Estado do Ceará, nos meses de março e abril de 2011. A amostra foi composta por 44 crianças. Prevaleceram crianças de sexo masculino (59,1%; faixa etária entre 24 a 72 meses (56,8%, e tempo de abrigamento superior a um ano (72,7%. Verificou-se que as crianças estavam na faixa de normalidade nutricional. Porém, 65,9% das crianças não alcançaram pelo menos um dos marcos do desenvolvimento propostos pelo Ministério da Saúde. O estudo possibilitou uma reflexão sobre como as crianças residentes em abrigos estão sendo assistidas pela equipe de saúde, tornando-se necessário realizar o acompanhamento de seu crescimento e desenvolvimento, a fim de intervir sobre as alterações encontradas.

  2. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    Science.gov (United States)

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  3. Radiological emergencies the first response

    International Nuclear Information System (INIS)

    2011-11-01

    This national training course about radiological emergencies first answer include: Targets and preparation for emergency response in case of a nuclear or radiological accident. Operations center, action guide for fire fighting, medical coverage, forensic test, first aid, basic instrumentation for radiation, safety equipment, monitoring radiation, gamma rays, personnel exposed protection , radiation exposure rate, injury and illness for radiation, cancer risk, contamination, decontamination and treatment, markers, personnel dosimetry, training, medical and equipment transportation, shielded and tools. Psychological, physical (health and illness), economical (agriculture and industry) and environment impacts. Terrorist attacks, security belts. Support and international agreements (IAEA)

  4. Recommendations for equipment requirements and specifications for digital and interventional radiology: Dosimetric aspects

    International Nuclear Information System (INIS)

    Suliman, I.I.; Zoetelief, J.

    2002-01-01

    The recognition of radiation induced injuries from fluoroscopically guided interventional procedures has resulted in the current demand for development of recommendations and standards to limit dose to both patients and staff. This paper outlines the recommendations drafted within the framework of European Project DIMOND III. The actual work involves survey and review of national and international documents as well as scientific publications in areas relevant to the digital and/or interventional radiology with an aim of developing recommendations for equipment requirements and specifications for digital and interventional radiology. A pilot study of experimental investigations in at least three hospitals will be conducted to test the requirements and the specifications, the result of which will be presented. The recommendations are expected to provide an effective means of dose reduction to both patients and staff while maintaining image quality adequate for the specific diagnosis or interventional procedure. Different components of x-ray systems that have direct impact on patient and staff doses have been considered. Where necessary a compromise between patient dose and image quality has been made. The dosimetric aspects of the recommendations propose detailed descriptions and limits to dosimetric information relevant to patient and staff doses. International recommendations on maximum patient entrance surface dose rate vary in the range from 25 to 65 mGy.min -1 for normal mode fluoroscopy. Maximum image intensifier or image receptor input dose rate around 0.1 Gy min -1 at a distance 30 cm from the image intensifier input surface has been generally recommended. Maximum fluoroscopic dose rate in air must not exceed 50 mGy.min -1 at a location depending on the configuration e.g. for undertable x-ray tube at 10 mm from the patient support on the patient side of the support. The use of pulsed fluoroscopy or low dose fluoroscopy is proposed as good options to minimize

  5. MEIO AMBIENTE E DESENVOLVIMENTO

    Directory of Open Access Journals (Sweden)

    Suely Salgueiro Chacon

    2009-12-01

    Full Text Available O objetivo deste artigo é resgatar elementos para subsidiar uma reflexão crítica sobre o modelo de desenvolvimento econômico prevalente na sociedade e as relações com o meio ambiente, sob a ameaça que ronda o destino da espécie humana, conforme afirmação de Lovelock (2006, p. 20 sobre o conceito de desenvolvimento sustentável: “uma ideia adorável se a tivéssemos aplicado 200 anos atrás, quando havia um bilhão de pessoas no mundo. Agora é tarde demais. Não há mais espaço para nenhum tipo de desenvolvimento. A humanidade tem que regredir”. Este artigo apresenta a evolução do conceito de desenvolvimento econômico sob a ótica da sustentabilidade, e interliga temas como: o ambientalismo, aglutinador de distintos pensamentos sobre as relações entre a sociedade e a natureza; o movimento ambiental, a fundamentar a disseminação do conceito de desenvolvimento sustentável, e a gestão ambiental, abordada como prática orientada pelo conceito de desenvolvimento sustentável.

  6. Radiology information management system, TOSRIM

    International Nuclear Information System (INIS)

    Tani, Yuichiro; Uchiyama, Akira; Kimura, Hirohito

    1991-01-01

    This is a report on a new type of distributed computer system for radiology departments named 'TOSRIM' (Toshiba radiology information management system), which is designed to be installed between medical diagnosis equipment and a host computer system in a hospital. Recently, a new type of host computer system has been developed which enables doctors to order any of the hospital's entire activities using terminals. By connecting 'TOSRIM' to this type of host computer system, many of the activities of a radiology department can be carried out via terminals without the use of examination requirement forms. As well as being connected to medical diagnosis equipment, 'TOSRIM' can also be connected to a medical imaging system which stores and displays medical images. By means of these connections, doctors will be able to diagnose medical images using display terminals without the need for films. (author)

  7. General-purpose radiological examination device

    Energy Technology Data Exchange (ETDEWEB)

    Slaby, J

    1978-03-15

    Equipment is described suitable for all radiological examinations using x-ray and neuroradiological diagnostic machines. The equipment consists of a gimbal suspension supporting a base plate and an imaging system, a gantry on which a neurological seat is pivoted capable of isocentrically positioning the patient's head.

  8. Environmental aspects at radiological protection in ArcelorMittal Monlevade

    International Nuclear Information System (INIS)

    Silva Filho, Cleber Marques; Soares Filho, Mauricio; Franco, Jose Otavio Andrade; Leite, Roberto Paulo; Goncalves, Breno Cunha; Costa, Jose Gustavo de Souza

    2010-01-01

    ArcelorMittal Monlevade Environmental Management of Radiological Protection is based on radiological protection team training, start up of radioactivity materials detection equipment in several steps of industrial processes and internal procedures according to CNEN - Nuclear Energy National Commission guidelines. At this way ArcelorMittal Monlevade seeks to guarantee the safety of employees, community, customers, equipment and the environment and their business. (author)

  9. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  10. Emergency Response Equipment and Related Training: Airborne Radiological Computer System (Model II)

    Energy Technology Data Exchange (ETDEWEB)

    David P. Colton

    2007-02-28

    The materials included in the Airborne Radiological Computer System, Model-II (ARCS-II) were assembled with several considerations in mind. First, the system was designed to measure and record the airborne gamma radiation levels and the corresponding latitude and longitude coordinates, and to provide a first overview look of the extent and severity of an accident's impact. Second, the portable system had to be light enough and durable enough that it could be mounted in an aircraft, ground vehicle, or watercraft. Third, the system must control the collection and storage of the data, as well as provide a real-time display of the data collection results to the operator. The notebook computer and color graphics printer components of the system would only be used for analyzing and plotting the data. In essence, the provided equipment is composed of an acquisition system and an analysis system. The data can be transferred from the acquisition system to the analysis system at the end of the data collection or at some other agreeable time.

  11. Radiology information management system, TOSRIM

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Yuichiro; Uchiyama, Akira; Kimura, Hirohito (Toshiba Corp., Kawasaki, Kanagawa (Japan))

    1991-02-01

    This is a report on a new type of distributed computer system for radiology departments named 'TOSRIM' (Toshiba radiology information management system), which is designed to be installed between medical diagnosis equipment and a host computer system in a hospital. Recently, a new type of host computer system has been developed which enables doctors to order any of the hospital's entire activities using terminals. By connecting 'TOSRIM' to this type of host computer system, many of the activities of a radiology department can be carried out via terminals without the use of examination requirement forms. As well as being connected to medical diagnosis equipment, 'TOSRIM' can also be connected to a medical imaging system which stores and displays medical images. By means of these connections, doctors will be able to diagnose medical images using display terminals without the need for films. (author).

  12. Radiation protection and quality assurance in dental radiology: II. Panoramic radiology

    International Nuclear Information System (INIS)

    Jodar-Porlan, S.; Alcaraz, M.; Martinez-Beneyto, Y.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.

    2001-01-01

    This paper studies 278 official reports on quality assurance in dental radiology in the context of the first revision of these dental clinics, as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an panoramic radiology apparatus, making a special reference to the brands they have available, as well as their physical features (kV, mA, filtration) and the deviations detected in their operation. Some of their features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionising radiation used in order to obtain the same tooth radiological image is presented. This paper shows, in a quantitative way, the characteristic features of panoramic radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)

  13. Report by the work-group on radiation protection in interventional radiology. Recommendations related to the improvement of radiation protection in interventional radiology

    International Nuclear Information System (INIS)

    2010-01-01

    This report aims at proposing recommendations for the improvement of the quality of radiation protection of workers and patients in the field of interventional radiology. These recommendations concern the training of health personnel, the application of the optimization principle to health professionals and patients, dosimetry and the definition of diagnosis reference levels. More particularly, these recommendations concern professions involved in interventional radiology, and take into account the experience of other European Union State members and recommendations made by the IAEA. The authors analyze the equipment, radiological actions, procedures and doses, practitioners, equipment used for radio-guided interventions. They discuss doses received by patients, patient monitoring and radio-induced lesions. Then, they address the role and training of the different interveners in radiation protection, the equipment maintenance issue, and personnel dosimetry and protection

  14. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  15. Analysis of licensed South African diagnostic imaging equipment ...

    African Journals Online (AJOL)

    Analysis of licensed South African diagnostic imaging equipment. ... Pan African Medical Journal ... Introduction: Objective: To conduct an analysis of all registered South Africa (SA) diagnostic radiology equipment, assess the number of equipment units per capita by imaging modality, and compare SA figures with published ...

  16. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  17. Plan for radiological security at a university health center

    International Nuclear Information System (INIS)

    Huiaman Mendoza, G.M.; Sanchez Riojas, M.M.; Felix JImenez, D.

    1998-01-01

    This work shows a radiological security plan applied to a Basic Radiological Service at a university health center. Factors taken into account were installation designs, equipment operation parameters, work procedures, image system and responsibilities

  18. Radiology in the 21st century

    International Nuclear Information System (INIS)

    Carson, P.L.; Seltzer, S.E.; Gore, J.C.; Heiiman, R.S.; Abrams, H.L.; Davis, K.A.; Henkelman, M.R.

    1987-01-01

    On the leading edge in ''high-tech'' medicine, radiology is experiencing several revolutions simultaneously that promise an exciting future. New imaging methods and digital technologies not only offer novel ways to view tissues but also provide opportunities for quantitative evaluation of function and even permit determination of metabolic status. New approaches to technology assessment are being explored that alter the ways in which equipment and procedures are introduced into clinical medicine. With the plethora of radiology services available, the radiologist must serve as a consultant in the triage of patients in radiology and the dissemination of information from radiology. For similar reasons, training in diagnostic radiology may eventually accommodate to the concept of specialization along organ-system lines. Without question, radiology is destined for an exciting period as it moves into the 21st century

  19. Radiological Control Technician: Phase 1, Site academic training study guides

    International Nuclear Information System (INIS)

    1992-10-01

    This volume is a study guide for training Radiological Control Technicians. Provided herein are support materials for learning radiological documentation, communication systems, counting errors and statistics, dosimetry, contamination control, airborne sampling program methods, respiratory protection, radiological source control, environmental monitoring, access control and work area setup, radiological work coverage, shipment and receipt for radioactive material, radiological incidents and emergencies, personnel decontamination, first aid, radiation survey instrumentation, contamination monitoring, air sampling, and counting room equipment

  20. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  1. A study regarding measurements of bacterial contamination levels in radiology room equipment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University Graduate School, Naju (Korea, Republic of); Song, Hyeon Je [Dept. of Clinical Pathology, Gwangju Health University, Gwangju (Korea, Republic of); Dong, Kyung Rae; Kim, Chang Bok [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Ryu, Jae Kwang [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-03-15

    Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), EosinMethylene Blue (EMB), ENDO (BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identifcation in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identifcation. Identifcation Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identifed from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confrmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital.

  2. A study regarding measurements of bacterial contamination levels in radiology room equipment

    International Nuclear Information System (INIS)

    Choi, Eun Jin; Song, Hyeon Je; Dong, Kyung Rae; Kim, Chang Bok; Ryu, Jae Kwang

    2017-01-01

    Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), EosinMethylene Blue (EMB), ENDO (BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identifcation in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identifcation. Identifcation Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identifed from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confrmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital

  3. Radiological equipment analyzed by specific developed phantoms and software

    International Nuclear Information System (INIS)

    Soto, M.; Campayo, J. M.; Mayo, P.; Verdu, G.; Rodenas, F.

    2010-10-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  4. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  5. Interventional radiology in cardiov ascular division of radiology department S.N.U hospital{sub s}taff roles and departmental management

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Chul; Cheung, Hwan [Seoul National University Hospital, Seoul (Korea, Republic of)

    1986-11-15

    As the angiography in the field of radiological sciences is being increasingly diversified in its techniques, clinical applications of interventional radiology are rapidly increasing not only for its usefulness in simple diagnosis but for its capabilities of affording, by means of radiological surveillance, biological data such as those concerning tissues which are even substitutionary or supplementary to treatment of diseases. During the last 5 years from July 1980 to 1984 such applications in the cardiovascular division showed a trend of radical increase and thus emerging as a new domain of radiological medicine which has vast influence on diagnosis and treatment. The present treatise presents the results of research performed on the following: 1) Need for close coordination among physicians, radiologists, and nurses in the radiology department. 2) Need for prior explanation to the patient of the procedure to be followed to relieve his anxiety. 3) Checking of the angiographic equipment and selection of technical factors. 4) Proper management of manpower including medical radiologists and assistant radiologists. 5) Sterilization of auxiliary equipment required for surgical operation. 6) Selection of a catheter and control of clinical materials such as contrast agents. 7) Supplementary arrangements for speedy performance of clinical services.

  6. The radiological safety in the use of nuclear technique -activities developed by Centro de Desenvolvimento da Tecnologia Nuclear - CNEN

    International Nuclear Information System (INIS)

    Wakabayashi, T.; Pereira, E.G.; Hirayama, T.

    1991-01-01

    The activities developed by the Centro de Desenvolvimento da Tecnologia Nuclear - CDTN supporting the users of nuclear techniques are described. The methodology used and future plans for the group are shown. (E.G.)

  7. Radiation protection in radiology services in the municipality of Sao Paulo, SP, Brazil

    International Nuclear Information System (INIS)

    Senise, Paulo H.; Silva, Ezequiel; Ruzene, Anderson A.; Braga, Adriano C.; Spirgatis, Armim; Medeiros, Regina B.

    2013-01-01

    The FIDI company providing service to local health care system is responsible for managing part of the services diagnostic imaging of Sao Paulo in the South and Southeast ( 60 % ), Eastern ( 20 % ) and Midwest (20 %), Brazil. The generation of images in the municipal net is performed in conventional manner. Since 2009 works a maintenance associated with the verification of the performance of radiological equipment (annual) and processing (monthly) one. In 2008, on the occasion of the agreement between the city hall and FIDI, conditions were evaluated for radiological protection in 52 care units of the municipality. Were carried out verification tests of performance in conventional equipment, mammographic and tomographic equipment, in 138 and 71 analog processors, according to current legislation. In 2008 , 33 % of the devices had technical problems that prevented its operation. Currently only 3.4 % of the 91 are in radiological equipment maintenance. In 2008 the majority of radiological equipment had more than 10 years of manufacturing, while today fixed equipment have been replaced by new ones and therefore the use of mammography and generally have 2 to 3 years of manufacture . Currently the 31 processors are operative in 2008, 28 % were out of order. The replacement of most of the equipment associated with program quality and preventive/corrective maintenance has kept the service in accordance with the law. (author)

  8. Desdobramento da qualidade no desenvolvimento de filmes flexíveis para embalagens

    Directory of Open Access Journals (Sweden)

    Miguel Paulo A. Cauchick

    2003-01-01

    Full Text Available Um dos métodos atuais importantes para o desenvolvimento de produtos é o QFD (Quality Function Deployment ou Desdobramento da Função Qualidade. O QFD consiste em um processo sistemático para traduzir a opinião do cliente em requisitos técnicos e operacionais, mostrando e documentando as informações na forma de matrizes. O método objetiva enfocar os itens mais importantes, proporcionando um mecanismo para alcançar vantagens competitivas no processo de desenvolvimento. Este trabalho destaca o conceito do QFD, citando uma aplicação em uma empresa que produz filmes flexíveis de polipropileno (BOPP. O trabalho apresenta alguns aspectos da introdução do método na empresa, apontando as dificuldades encontradas, resultados e benefícios decorrentes da implantação. Dentre os benefícios gerados, destacam-se a importância do papel do QFD como um método para sistematizar o processo de desenvolvimento, bem como outros benefícios para a equipe, tais como melhoria nas habilidades de planejamento, disseminação do conhecimento e melhoria de comunicação entre as áreas funcionais.

  9. Westinghouse radiological containment guide

    International Nuclear Information System (INIS)

    Aitken, S.B.; Brown, R.L.; Cantrell, J.R.; Wilcox, D.P.

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste

  10. Westinghouse radiological containment guide

    Energy Technology Data Exchange (ETDEWEB)

    Aitken, S.B. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Brown, R.L. [Westinghouse Hanford Co., Richland, WA (United States); Cantrell, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Wilcox, D.P. [West Valley Nuclear Services Co., Inc., West Valley, NY (United States)

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste.

  11. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453

    International Nuclear Information System (INIS)

    Costa, Rogerio Ferreira da

    2013-01-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  12. Radiologic protection in intensive therapy units

    International Nuclear Information System (INIS)

    Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S.; Derech, Rodrigo D.A.

    2013-01-01

    The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)

  13. Liderança e trabalho em equipe: um estudo de caso da equipe de enfermagem de um hospital geral de Belo Horizonte

    Directory of Open Access Journals (Sweden)

    Karla Rona Silva

    2011-12-01

    Full Text Available O trabalho em equipe é considerado um importante pressuposto para a reorganização do processo de trabalho. Essa modalidade visa uma abordagem mais integral, resolutiva e efetiva frente às atividades coletivas e interdisciplinares. Para a equipe de enfermagem este tipo de trabalho é de fundamental importância e depende de uma liderança capaz de gerenciar os conflitos e anseios que por ventura surgirem. Tal liderança, muitas vezes, eleita pelo próprio grupo, envolve a capacidade de influenciar pessoas. Assim, esse estudo tem por objetivo analisar o papel das lideranças e sua efetividade para o trabalho no interior de uma equipe assistencial de enfermagem. Os sujeitos da pesquisa em questão são quatro técnicos de enfermagem do setor de atendimento de urgência e emergência de um hospital geral de grande porte, localizado em Belo Horizonte. Uma vez que a questão da liderança apresenta-se, na maioria das vezes, de forma subjetiva, não sendo possível analisá-la em sua plenitude em questionários fechados, optou-se pela utilização da observação participante como principal ferramenta metodológica para coleta dos dados da pesquisa. Com o estudo, pode-se observar que a equipe, de uma forma geral, possui um bom entrosamento e uma postura ético-profissional pertinente ao desenvolvimento da assistência e do cuidado frente ao paciente. No entanto, a observação participante nos revelou a existência de uma liderança autoritária exercida por um dos membros da equipe. Apesar da insatisfação gerada nos demais membros da equipe, essa postura não prejudica o desenvolvimento do trabalho.

  14. Development of mobile radiological assessment laboratory

    International Nuclear Information System (INIS)

    Pujari, R.N.; Saindane, Shashank S.; Jain, Amit; Parmar, Jayesh; Narsaiah, M.V.R.; Pote, M.B.; Murali, S.; Chaudhury, Probal

    2018-01-01

    During any emergency situations real-time radiation measurements and the fast analysis of the measured radiological data are of crucial importance. The newly developed mobile vehicle based laboratory known as 'Radiological Assessment Laboratory' (RAL) can be used for real time measurements in different radiation emergency scenarios, such as the release of radioactive materials from a radiological/nuclear incident, during search of an orphan source or during radioisotope transportation. RAL is equipped with several high sensitive detectors/systems such as NaI(Tl) gamma spectrometers, large size plastic scintillators and air-sampler, along with GPS and data transfer capability through GSM modem

  15. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    Science.gov (United States)

    Belinato, W.; Souza, D. N.

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  16. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    International Nuclear Information System (INIS)

    Belinato, W.; Souza, D.N.

    2011-01-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide 'Medical radiology: security and performance of equipment.' In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  17. Influence of physical parameters on radiation protection and image quality in intra-oral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W. [Instituto Federal de Ensino Basico, Tecnico e Tecnologico da Bahia, Av. Amazonas, 1350-45030-220, Zabele, Vitoria da Conquista, BA (Brazil); Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon s/n, 49100-000 Rosa Elze, Sao Cristovao, SE (Brazil); Souza, D.N., E-mail: divanizi@ufs.br [Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon s/n, 49100-000 Rosa Elze, Sao Cristovao, SE (Brazil)

    2011-10-01

    In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide 'Medical radiology: security and performance of equipment.' In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.

  18. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  19. Emergency Response Equipment and Related Training: Airborne Radiological Computer System (Model II) user's manual

    International Nuclear Information System (INIS)

    David P. Colton

    2007-01-01

    The materials included in the Airborne Radiological Computer System, Model-II (ARCS-II) were assembled with several considerations in mind. First, the system was designed to measure and record the airborne gamma radiation levels and the corresponding latitude and longitude coordinates, and to provide a first overview look of the extent and severity of an accident's impact. Second, the portable system had to be light enough and durable enough that it could be mounted in an aircraft, ground vehicle, or watercraft. Third, the system must control the collection and storage of the data, as well as provide a real-time display of the data collection results to the operator. The notebook computer and color graphics printer components of the system would only be used for analyzing and plotting the data. In essence, the provided equipment is composed of an acquisition system and an analysis system. The data can be transferred from the acquisition system to the analysis system at the end of the data collection or at some other agreeable time

  20. THE WORK PROCESS IN RADIOLOGICAL NURSING: INVISIBILITY OFIONIZING RADIATION

    OpenAIRE

    Melo,Juliana Almeida Coelho de; Gelbcke,Francine Lima; Huhn,Andrea; Vargas,Mara Ambrosina de Oliveira

    2015-01-01

    ABSTRACT Qualitative descriptive and exploratory research, performed with 20 nursing professionals working in a general radiology unit and surgery center with the "C-arm" equipment, and the hemodynamics unit of a southern Brazilian teaching hospital. Aim was to analyze the dimensions of the work process for radiological technology nurse professionals. This paper made clear that radiological technologies are outside nursing, which leads to the invisibility of ionizing radiation, leading to ina...

  1. French days of radiology (J.F.R.) 2005

    International Nuclear Information System (INIS)

    2005-01-01

    Five parts are presented, the nuclear safety authority informs the radiologists on the evolution of the regulation in radiation protection and its practical application; statements of medical and dental radiodiagnosis equipments; licensing for use of radiodiagnosis installation; to use the diagnosis reference levels in radiology to optimize the practices; radiation protection in interventional radiology. (N.C.)

  2. Role of radiology in occupational medicine

    International Nuclear Information System (INIS)

    Vehmas, T.

    2004-01-01

    This review discusses the contribution of radiology to occupational medicine as well as work-related problems in radiology dept.s. Research issues are emphasized. Radiology has been used especially when diagnosing occupational respiratory and locomotive system problems and solvent-induced encephalo- and hepatopathy. The aim of research in these areas is usually to characterize occupational diseases and to identify physico-chemical hazards in the work place by comparing between groups of workers and non-exposed controls. Radiological imaging allows an objective characterization of the disease, and it may clarify the pathogenesis of the process and provide a useful epidemiological tool. Advanced statistical methods are often needed to adjust analyses for confounding variables. As the diagnostic requirements are increasing, more sensitive and sophisticated radiological methods, such as high-resolution computed tomography, magnetic resonance imaging and magnetic resonance spectroscopy, may be required for the early recognition of occupational health risks. This necessitates good cooperation between occupational health units and well-equipped imaging dept.s. Considering occupational problems in radiology departments, the increasing use of digital radiology requires ergonomic measures to control and prevent locomotive problems caused by work with computers. Radiation protection measures are still worth concern, especially in interventional radiology

  3. A teoria do “desenvolvimento fragmentador”

    Directory of Open Access Journals (Sweden)

    Fred Scholz

    2010-04-01

    Full Text Available O pensamento desenvolvimentista do passado era dominado pela ideia de que o subdesenvolvimento do Terceiro Mundo poderia ser superado mediante ajuda técnica, financeira e pessoal dos países do Norte. A meta era alcançar o nível de desenvolvimento dos países ocidentais industrializados por meio de um desenvolvimento retardatário. Na base dessa ideia estava, por um lado, o consenso de valores ocidental-humanitários, que, o mais tardar desde a época do Esclarecimento, determinou o pensar e o devir social. Por outro lado, a ideia baseou-se na responsabilidade histórica (surgida das condições da Guerra Fria, aceita política e socialmente do "Ocidente" para com os chamados países em desenvolvimento, na sua maioria ex-colônias. Argumenta-se, neste artigo, que a ideia de um desenvolvimento retardatário deve, na era da globalização, ser substituída pelo fato de um desenvolvimento fragmentador.

  4. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  5. Implementation of DICOM Modality Worklist at Patient Registration Systems in Radiology Unit

    Science.gov (United States)

    Kartawiguna, Daniel; Georgiana, Vina

    2014-03-01

    Currently, the information and communication technology is developing very rapidly. A lot of hospitals have digital radiodiagnostic modality that supports the DICOM protocol. However, the implementation of integrated radiology information system with medical imaging equipment is still very limited until now, especially in developing countries like Indonesia. One of the obstacles is high prices for radiology information system. Whereas the radiology information systems can be widely used by radiologists to provide many benefit for patient, hospitals, and the doctors themselves. This study aims to develop a system that integrates the radiology administration information system with radiodiagnostic imaging modalities. Such a system would give some benefits that the information obtained is more accurate, timely, relevant, and accelerate the workflow of healthcare workers. This research used direct observation method to some hospital radiology unit. Data was collected through interviews, questionnaires, and surveys directly to some of the hospital's radiology department in Jakarta, and supported by the literature study. Based on the observations, the prototype of integrated patient registration systems in radiology unit is developed and interfaced to imaging equipment radiodiagnostic using standard DICOM communications. The prototype of radiology patient registration system is tested with the modality MRI and CT scan.

  6. Desenvolvimento econômico, desigualdade e saúde

    Directory of Open Access Journals (Sweden)

    Prata Pedro Reginaldo

    1994-01-01

    Full Text Available O autor se refere a dimensão socioeconômica, individual e coletiva do fenômeno saúde-doença. Refere-se também ao fato das populações estarem sobre a influência desigual de fatores de risco e de proteção à saúde. Discute as desigualdades no desenvolvimento e a relação entre desenvolvimento, riqueza, saúde e justiça social. Questiona as teorias de desenvolvimento econômico, diferenciando desenvolvimento de crescimento. Cunha os conceitos de armadilha do desenvolvimento e refugiados sociais. Define uma comunidade saudável. Propõe a necessidade de mudança no modelo de desenvolvimento. Baliza o papel e as limitações do setor saúde no que diz respeito a iniqüidade social.

  7. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    using dose guidance (reference) levels in radiology and nuclear medicine examinations, Radiological protection of the embryo and foetus in pregnant patients, Radiological protection of paediatric patients, Radiological protection of patients in radiotherapy: external beam, Radiological protection of patients in radiotherapy: brachytherapy, Radiological protection of patients in biomedical research, Influence of standardization in the design and development of medical radiological equipment on the radiological protection of patients, Education, training and continuous professional development in the radiological protection of patients, Topics for research and development in the radiological protection of patients, Implementation of regulations on the radiological protection of patients

  8. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    using dose guidance (reference) levels in radiology and nuclear medicine examinations, Radiological protection of the embryo and foetus in pregnant patients, Radiological protection of paediatric patients, Radiological protection of patients in radiotherapy: external beam, Radiological protection of patients in radiotherapy: brachytherapy, Radiological protection of patients in biomedical research, Influence of standardization in the design and development of medical radiological equipment on the radiological protection of patients, Education, training and continuous professional development in the radiological protection of patients, Topics for research and development in the radiological protection of patients, Implementation of regulations on the radiological protection of patients.

  9. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  10. Radiological security of portable equipment used in the industry; Seguridad radiologica de equipos portatiles utilizados en la industria

    Energy Technology Data Exchange (ETDEWEB)

    Cateriano, M.A. [Autoridad Regulatoria Nuclear, Av. Del Libertdor 8250, (C1429BNP), Ciudad Autonoma de Buenos Aires (Argentina)]. e-mail: mcateria@sede.arn.gov.ar

    2006-07-01

    The industrial meters with encapsulated sources are used intensely in the present time due to the economic benefits that generate. Their use in all the one world has been reflected in an improvement of the quality of the analyzed product and of one optimization of the production process, allowing to carry out these measurements and controls without interrupting the process and in non destructive form generating an energy saving in turn and of materials. Although these industrial meters are intrinsically safe for design in the portable meters their safety also is strongly governed in the strict pursuit of procedures and in the adequate personnel's training that operate these equipment. In the Argentine Republic in 2005 the Nuclear Regulatory Authority (RNA) had registered a quantity of 160 portable equipment. In the period 1995-2003, 2 incidents took place with these equipment one of them used to measure soils humidity of Troxler trademark containing a source of Am-241(Be) of 370 MBq and the remaining one also of Troxler trademark used to measure density and humidity of soils containing 2 sources of Cs-137 of 296 MBq and Am-241(Be) of 1.48 GBq respectively. The incidents were developed without relevant radiological implications had taken place. In this work those mentioned incidents are analyzed in order to determining the causes that originated the same ones, for this way to be able to elaborate recommendations with the purpose of to correct errors and to diminish the recurrence probability improving the safety in the use of these equipment. From the analyses of these incidents result that should put on more emphasis in the personnel training and the invigoration of the safety culture in the use of the industrial meters. Also a present panorama of the inventory of equipment, sources and users that possess these portable meters in the Argentine Republic is also presented. (Author)

  11. Recommended radiological controls for tritium operations

    International Nuclear Information System (INIS)

    Mansfield, G.

    1992-01-01

    This informal report presents recommendations for an adequate radiological protection program for tritium operations. Topics include hazards analysis, facility design, personnel protection equipment, training, operational procedures, radiation monitoring, to include surface and airborne tritium contamination, and program management

  12. Radiological protection program in x-ray diagnostic facilities

    International Nuclear Information System (INIS)

    Melara F, N.E.

    1996-01-01

    This paper presents a basic document to initiate a discussion which will originate a Unified Protocol in Latin America and the Caribbean for radiological protection in the installations of medical radiology. The following principal elements are considered an inherent part of radiology protection: 1. Quality control of equipment. 2. Conditions in the dark room which coincide in the quality of the image. Levels of patient exposure and the processes for the quality control of the processors are not discussed, and it is limited to the installation of radiographic medical x-ray equipment, stationary and mobile. Each point to be put into effect is presented in a diagram, frequency and criteria for acceptance. A detailed explanation of each point along with a clear explanation of the recommended method for each follows in the same order in which they are presented in the diagram. Finally adequate forms for easily acquiring data are presented. (author)

  13. Radiology textbook for dental chair assistants

    International Nuclear Information System (INIS)

    Diewald, H.

    1990-01-01

    One of the goals of the X-ray Ordinance (of January 8, 1987) being to protect individuals or the population at large against the harmful effects of X-rays, every dentist using X-ray equipment in his practice has to acquire the necessary expert knowledge in radiation protection. The same applies to dental chair assistants, who under permanent supervision of the responsible dentist, carry out radiological examinations. Assistants have to give proof of the necessary training in radiation protection in connection with the methods and equipment applied in the practice. The training consists of a theoretical and practical part tailored to the assistants' practical work, and lectures on radiological hazards and the relevant radiation protection measures. The subject matters of the courses in radiation protection are defined by the X-ray Ordinance, as well as the examination. The author of this textbook has collected a list of examination questions and problems taken from the practice. They completely cover the various subject matters of dental radiology so that the required knowledge can be acquired, which will ensure in practice good image quality and optimal radiation protection. (orig./HP) [de

  14. ICRP PUBLICATION 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology

    International Nuclear Information System (INIS)

    Khong, P-L.; Ringertz, H.; Donoghue, V.; Frush, D.; Rehani, M.; Appelgate, K.; Sanchez, R.

    2013-01-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities – radiography and fluoroscopy, interventional radiology, and computed tomography – are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation

  15. Quality control for dental X-rays equipment and film developers

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1998-01-01

    Quality control in five dental X-ray equipments, film and film developers was done. It was for evaluating the radiologic practices in the odontologic services too. This work was made based on international standards, the results will be used for future works in quality assurance in dental radiology

  16. Work plan for the radiological survey for the David Witherspoon, Incorporated, Landfill-1630 site, Knoxville, Tennessee

    International Nuclear Information System (INIS)

    1996-07-01

    This work plan establishes the methods and requirements for performing a radiological survey at the David Witherspoon, Incorporated, Landfill-1630 Site, Knoxville, Tennessee (DWI 1630 Site) in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The radiological survey will identify the radiological contamination level of the equipment and debris stored at the DWI 1630 Site. The data generated from the survey activities will support the decisions for characterization of the equipment/debris and aid in subsequent disposition and waste handling. The survey activities to be performed under this work plan include an equipment radiological survey, a walkover survey, and an immunoassay testing for polychlorinated biphenyls (PCBs). This work plan includes a quality assurance (QA)/quality control (QC) project plan, a health and safety (H ampersand S) plan, and a waste management plan

  17. Fundamentals for cost calculations of X-ray equipment

    International Nuclear Information System (INIS)

    Bossard, F.

    1985-01-01

    Economic implications of running an X-ray departement in Switzerland will be illustrated by comparing operating costs of private radiological institutes with and without CT to the operating costs of large radiological departments in hospitals with and without CT and to the operating costs of simple X-ray equipment in general practicioners' offices. - These costs calculations form the basis for cost-benefit analyses. (orig.) [de

  18. Challenges in setting up quality control in diagnostic radiology ...

    African Journals Online (AJOL)

    Journal Home > Vol 24, No 4 (2015) >. Log in or ... Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the ... Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study.

  19. Pediatric digital radiography education for radiologic technologists: current state

    International Nuclear Information System (INIS)

    Morrison, Gregory; Culbertson, John; Carbonneau, Kira; John, Susan D.; Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy

    2011-01-01

    Digital radiography (DR) is one of several new products that have changed our work processes from hard copy to digital formats. The transition from analog screen-film radiography to DR requires thorough user education because of differences in image production, processing, storage and evaluation between the forms of radiography. Without adequate education, radiologic technologists could unknowingly expose children to higher radiation doses than necessary for adequate radiograph quality. To evaluate knowledge about image quality and dose management in pediatric DR among radiologic technologists in the U.S. This communication describes a survey of 493 radiologic technologists who are members of the American Society of Radiologic Technologists (ASRT) and who evaluated the current state of radiological technologist education in image quality and dose management in pediatric DR. The survey included 23 survey questions regarding image acquisition issues, quality assurance, radiation exposure and education in DR of infants and children. Radiologic technologists express many needs in areas of training and education in pediatric DR. Suggested improvements include better tools for immediate feedback about image quality and exposure, more information about appropriate technique settings for pediatric patients, more user-friendly vendor manuals and educational materials, more reliable measures of radiation exposure to patients, and more regular and frequent follow-up by equipment vendors. There is a clear and widespread need for comprehensive and practical education in digital image technology for radiologic technologists, especially those engaged in pediatric radiography. The creation of better educational materials and training programs, and the continuation of educational opportunities will require a broad commitment from equipment manufacturers and vendors, educational institutions, pediatric radiology specialty organizations, and individual imaging specialists. (orig.)

  20. [Regulating radiological protection and the role of health authorities].

    Science.gov (United States)

    Arias, César F

    2006-01-01

    This article summarizes the development of protection against ionizing radiation and explains current thinking in the field. It also looks at the decisive role that regulatory agencies for radiological protection must play and the important contributions that can be made by health authorities. The latter should take an active part in at least three aspects: the formal education of health personnel regarding radiological protection; the medical care of individuals who are accidentally overexposed, and the radiological protection of patients undergoing radiological procedures. To this end, health professionals must possess sufficient knowledge about radiological protection, promote the use of proper equipment, and apply the necessary quality assurance procedures. Through their effective intervention, national health authorities can greatly contribute to reducing unnecessary doses of radiation during medical procedures involving radiation sources and decrease the chances that radiological accidents will take place.

  1. O DIREITO FUNDAMENTAL AO DESENVOLVIMENTO SUSTENTÁVEL

    OpenAIRE

    Fernandes, Jeferson Nogueira

    2012-01-01

    Este artigo jurídico trata do direito fundamental do ser humano ter um desenvolvimento sustentável, e tem como objetivo identificar o desenvolvimento sustentável como sendo um direito fundamental consagrado universalmente. Em sua elaboração foi utilizado o seguinte material: textos doutrinários, legislação nacional pertinente e documentos internacionais. A conclusão indica que: o desenvolvimento sustentável é um direito fundamental do homem e que devemos manter equilibrada a relação ambiente ...

  2. Saúde e desenvolvimento

    Directory of Open Access Journals (Sweden)

    Ana Luiza D'Ávila Viana

    Full Text Available Considerando que os modernos sistemas de saúde são o resultado da complexa interação de processos econômicos, políticos e sociais, o objetivo do trabalho é discutir a relação entre saúde e desenvolvimento no Brasil, mostrando que o esgotamento do modelo liberal de política econômica abre nova perspectiva para a retomada do desenvolvimento, entendido como combinação entre crescimento da economia, mudanças na estrutura produtiva e melhora das condições de vida da população. O complexo produtivo da saúde joga papel decisivo nesse processo, pois constitui um campo em que inovação tecnológica e acumulação de capital geram oportunidades de investimento, trabalho e renda, além de produzir avanços importantes para melhorar o estado de saúde das pessoas. A recente adoção de políticas públicas voltadas para articular, de forma positiva, aspectos da política econômica e da política social revela que a questão do desenvolvimento nacional ganhou nova centralidade na agenda governamental, o que abre a perspectiva de maior integração entre a lógica econômica e a lógica sanitária. Entretanto, é preciso reconhecer que o Brasil ainda não logrou alcançar uma associação virtuosa entre saúde e desenvolvimento.

  3. Report on the radiological accident in Goiania, Goias, Brazil

    International Nuclear Information System (INIS)

    Alves, R.N.

    1988-01-01

    The report describes the radiological accident occured in Goiania, Brazil, in september 1987. The following aspects concerning the accident are presented in specific chapters: 1- evaluation of the accident and the first aids, 2- attendance to the victims of Goiania radiological accident, 3- decontamination, 4- radioactive wastes arising from the accident, 5- working personnel and technical cooperation, 6- equipments and 7- radiation protection: limits and recommendations [pt

  4. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  5. Survey of diagnostic radiology in the Republic of Ireland

    International Nuclear Information System (INIS)

    Cunningham, J.D.; Howett, D.; Hone, C.; Mulholland, C.

    1988-03-01

    This survey examined a number of aspects of the practice of diagnostic radiology in Ireland. These included the frequency of examinations, the gonadal and active bone marrow doses to patients, the genetically significant dose, the standard of design of x-ray rooms and of performance of equipment, and an inventory of equipment currently in use (author)

  6. Quality assurance programme in diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, A.A.

    1996-01-01

    One hundred years after the discovery of X-rays, they continue being nowadays part of physicians' daily activities, and the diagnosis through the use of X-ray equipment is one of the most important fields in clinical medicine, thus becoming the most important cause of human exposure to artificial sources. For this reason, in the last twenty years, most of the developed countries did the utmost to establish programs which could warrant the quality of the radiographic image. Aiming the protection of human being against the harmful effects of ionizing radiations, in December 1980, World Health Organization decided to form a group of professionals highly experienced in medical radiology, and initiate an inspection and quality control program. In September 1988, the Group of Studies of the Program Related to Radiological Protection of the Commission in the European Communities, prepared a working paper in which guidelines were set up regarding quality of images, dosage to patient, and associated radiographic factors, necessary to obtain acceptable radiologic performance. In Brazil, efforts driven in this direction, guided by some equipment testing, starting in 1990, began to be more known. When the Director and the Head of Radiology in the Military Police Hospital of the State of Rio de Janeiro (HPM) reamed about these efforts, they decided to contact the Institute for Radioprotection and Dosimetry (IRD) of Comissao Nacional de Energia Nuclear and submit the problem of low radiologic performance and increasing rates of rejection. Thus, with the coincidence of interests and needs, along with a proposal from the Commission of the European Communities (CEC), IRD decided to offer the author laboratory support to elaborate a Quality Assurance Program (QAP) to be implemented in HPM. (author)

  7. Foco na inovação e complementaridade em equipes de direção no desenvolvimento de novas empresas tecnológicas

    Directory of Open Access Journals (Sweden)

    Benny Kramer Costa

    2009-08-01

    Full Text Available Muitas novas empresas de base tecnológicas são criadas devido às necessidades de produção e comercialização que se impõem aos aficionados em tecnologia que têm foco inicial apenas na inovação para a criação de produtos. Uma das conseqüências comuns deste foco exacerbado na inovação é a formação de equipes de direção, nas quais falta a complementaridade de alguém hábil como empreendedor e gestor de negócios. O objetivo deste trabalho é apresentar um estudo comparativo de casos de novas pequenas e médias empresas (PME tecnológicas criadas por aficionados em tecnologia e da influência da complementaridade de habilidades entre os membros das equipes de direção sobre o desenvolvimento dessas empresas. O estudo identifica fatores viabilizadores e limitadores impostos pelo foco exacerbado na inovação. Ele também descreve algumas práticas úteis para se superar dificuldades provocadas pela falta de atenção inicial dos fundadores às competências empreendedoras e de gestão. A abordagem metodológica é descritiva e baseada em métodos qualitativos de pesquisa, integrando o estudo multi-caso (EISENHARDT, 1989. A coleta dos dados foi feita principalmente com entrevistas semiestruturadas em profundidade. A análise incluiu as etapas de análise intracaso e intercaso dos dados (MILES e HUBERMAN, 1994. Como resultado, verificou-se que a formação e o histórico das experiências dos diferentes fundadores se mostraram relevantes para explicar o tipo de foco dado à inovação tecnológica e às questões de negócio.

  8. Policy of productive development and energy efficiency; Politica de desenvolvimento produtivo e eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Naturesa, Jim Silva [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Civil Arquitetura e Urbanismo. Nucleo Interdisciplinar de Planejamento Energetico], e-mail: cam@fec.unicamp.br; Mariotoni, Carlos Alberto [Faculdade Politecnica de Jundiai (FPJ), SP (Brazil). Anhanguera Educacional

    2008-07-01

    The new industry policy in Brazil called PDP (Politica de Desenvolvimento Produtivo) and implications on Brazilian energy efficiency program are discussed. The PINTEC - Industrial Research for Technology Innovation (2003/05) indicates a low R and D and I investment of the Brazilian industries. It is expected that and energy efficiency project can be seen as an innovation project because this brings new equipment and a more advanced knowledge to industry, which helps to reduce electrical energy consumption, consumer' bills and production costs. (author)

  9. Radiometer evaluation of X-rays equipment in the region of Aracatuba, Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Fernandes, Marco A.R.

    2009-01-01

    This paper presents the basic concepts of radiation protection to guide the health care professionals who use equipment emitting ionizing radiation on the correct handling of the beams of radiation. Radiometric evaluations were conducted in 1665 in X-ray equipment, installed in dental surgeries and clinics, hospitals and radiology services, during the years 1996 to 2003 in the region of Aracatuba. Tests of radiometry are presented as a technical report where the parameters are quantified physical and radiological verifying its compliance with the established by legislation. The distribution of reports by type of unit shows that the vast majority of equipment is of periapical dental x-rays (72%), 25% of equipment is medical equipment for radiology and 3% is dental equipment panoramic model (orthodontic documentation). Among the physical parameters analyzed, the length of the browser was showing more variance compared to the required by law, this fact may also contribute to gaps in the rate of the radiation dose and the size of field in the skin of the patient, the that can easily be resolved simply to replace the piece at the outlet of the head. During the completion of visits to services, it also noted a gap in the training of professionals who operate this equipment emitting radiation, warning of the need for specific training in the area. (author)

  10. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  11. Paediatric interventional radiology

    International Nuclear Information System (INIS)

    McLaren, Clare

    2014-01-01

    Paediatric interventional radiology (PIR) is a rapidly-growing subspecialty, which offers a wide range of procedures applicable to almost all areas of hospital paediatrics. There are many important differences between paediatric and adult practice in interventional radiology, including disease processes and treatment goals, anatomical considerations, periprocedural patient management, radiation exposure optimisation and legal aspects. The use of retrievable or absorbable interventional devices such as stents will probably become more widespread in PIR practice. Recent advances in the technology of imaging equipment have been accompanied by an increase in the complexity of the work done by the radiographer. These developments present challenges and opportunities related to training and maintenance of skills, staffing arrangements, and the potential for advanced practice. It is likely that specialisation in PIR will become a more common role for radiographers in the future

  12. Radiological safety evaluation report for NUWAX-79 exercise

    International Nuclear Information System (INIS)

    King, W.C.

    1979-03-01

    An analysis of the radiological safety of the NUWAX-79 exercise to be conducted on the Nevada Test Site in April 1979 is given. An evaluation of the radiological safety to the participants is made using depleted uranium (D-38) in mock weapons parts, and 223 Ra and its daughters as a radioactive contaminant of equipment and terrain. The radiological impact to offsite persons is also discussed, particularly for people living at Lathrop Wells, Nevada, which is located 7 miles south of the site proposed for the exercise. It is the conclusion of this evaluation that the potential radiological risk of this exercise is very low, and that no individual should receive exposure to radioactivity greater than one-tenth of the level permitted under current federal radiation exposure guidelines

  13. Specific developed phantoms and software to assess radiological equipment image quality

    International Nuclear Information System (INIS)

    Verdu, G.; Rodenas, F.

    2011-01-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  14. Specific developed phantoms and software to assess radiological equipment image quality

    Energy Technology Data Exchange (ETDEWEB)

    Verdu, G., E-mail: gverdu@iqn.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Ingenieria Quimica y Nuclear; Mayo, P., E-mail: p.mayo@titaniast.com [TITANIA Servicios Teconologicos, Valencia (Spain); Rodenas, F., E-mail: frodenas@mat.upv.es [Universidad Politecnica de Valencia (Spain). Dept. de Matematica Aplicada; Campayo, J.M., E-mail: j.campayo@lainsa.com [Logistica y Acondicionamientos Industriales S.A.U (LAINSA), Valencia (Spain)

    2011-07-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be automatized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques, etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (mAs). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (author)

  15. DIREITOS HUMANOS, DESENVOLVIMENTO SUSTENTÁVEL E SUSTENTABILIDADE

    OpenAIRE

    Carvalho, Sonia Aparecida de; Silva, Denival Francisco da; Adolfo, Luiz Gonzaga Silva

    2015-01-01

    Este artigo trata da relação intrínseca entre os direitos humanos, o desenvolvimento sustentável e a sustentabilidade. Seu objetivo geral consiste em analisar o modelo de desenvolvimento implementado e a necessária proteção e preservação do meio ambiente ligado à defesa dos direitos humanos. Os objetivos específicos pretendem investigar a distinção dos termos sustentabilidade e desenvolvimento sustentável, como a concretização do direito à sustentabilidade, os critérios e as dimensões da sust...

  16. Gestões do desenvolvimento e desenvolvimentos da gestão: da unilateralidade reificada à dialogicidade da simbiose homem/natureza

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Justen

    Full Text Available Este artigo, ao situar culturalmente os fenômenos da gestão e do desenvolvimento, em sua concepção tradicional, no projeto da modernidade e ao identificar o predomínio da unilateralidade reificada na interface entre gestão e desenvolvimento - a primeira vista como instrumento técnico submisso à via clássica do segundo - almeja evidenciar as potencialidades da compreensão e da construção de alternativas, tanto para a gestão como para o desenvolvimento, a partir da ressignificação dessa interface. Para tanto, o esforço foi direcionado ao resgate do que é comum aos fenômenos da gestão e do desenvolvimento - os substratos antropológico e ecológico -, nucleados nos princípios da reciprocidade dialógica, concretizadora da condição antropológica, e da finitude, caracterizadora da condição ecológica. Ao final, são apresentadas oito potenciais contribuições advindas da exploração renovada da interface entre a gestão e o desenvolvimento. Propôs-se, ainda, a substituição da lógica instrumental da eficiência financeira, comum à concepção tradicional dos fenômenos estudados, pela lógica da simbiose dialógica homem/natureza, uma vez que, como fenômenos sociais, desenvolvimento e gestão, mediados pelo meio, também são ecológicos em sua essência.

  17. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  18. Recommendations of the Indian College of Radiology

    International Nuclear Information System (INIS)

    Gupta, B.D.

    1980-01-01

    The deliberations at the 3rd Southern Regional Conference of Radiologists and the midterm teaching sessions of the Indian College of Radiology held in June 1979 are reported. The various recommendations were formulated and discussed to ensure uniformity in pattern for practice and training in radiology throughout the country. Some of the significant topics discussed included: mode of examination, standard of training and norms for equipping the radiology department, duration and type of course, nomenclature of post-graduate course, under-graduate training in radio-diagnosis and other imaging techniques, under-graduate training in radiotherapeutic oncology, representation in Indian Medical Council, post-graduate and diploma training courses in radio-diagnosis and imaging techniques and post-graduate training course in radiation oncology. (K.B.)

  19. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2011-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  20. Comprehensive Clinical Audits of Diagnostic Radiology Practices: A Tool for Quality Improvement. Quality Assurance Audit for Diagnostic Radiology Improvement and Learning (QUAADRIL)

    International Nuclear Information System (INIS)

    2010-01-01

    Interest in quality assurance processes and quality improvement in diagnostic radiology is being driven by a number of factors. These include the high cost and complexity of radiological equipment, acknowledgement of the possibility of increasing doses to patients, and the importance of radiological diagnosis to patient management within the health care environment. To acknowledge these interests, clinical audits have been introduced and, in Europe, mandated under a European Directive (Council Directive 97/47/EURATOM). Comprehensive clinical audits focus on clinical management and infrastructure, patient related and technical procedures, and education and research. This publication includes a structured set of standards appropriate for diagnostic radiology, an audit guide to their clinical review, and data collection sheets for the rapid production of reports in audit situations. It will be a useful guide for diagnostic radiology facilities wishing to improve their service to patients through timely diagnosis with minimal radiation dose.

  1. Code of practice and design principles for portable and transportable radiological protection systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1980-10-01

    The Code of Practice and design principles for portable and transportable radiological protection systems are presented in three parts. Part 1 specifies the requirement for Radiological Protection Instrumentation (RPI) including operational characteristics and the effects of both a radiation and non-radiation environment. Part 2 satisfies the requirement for RPI equipment as regards the overall design, the availability, the reliability, the information display, the human factors, the power supplies, the manufacture and quality assurance, the testing and the cost. Part 3 deals with the supply, location and operation of the RPI equipment. (U.K.)

  2. Study of effective dose of various protocols in equipment cone beam CT

    International Nuclear Information System (INIS)

    Soares, M. R.; Maia, A. F.; Batista, W. O.; Caldas, L. V. E.; Lara, P. A.

    2014-08-01

    Currently the cone beam computed tomography is widely used in various procedures of dental radiology. Although the doses values associated with the procedures of cone beam CT are low compared to typical values associated with dental radiology procedure in multi slices CT. However can be high compared to typical values of other techniques commonly used in dental radiology. The present scenario is a very wide range of designs of equipment and, consequently, lack of uniformity in all parameters associated with x-ray generation and geometry. In this context, this study aimed to evaluate and calculate the absorbed dose in organs and tissues relevant and estimate effective dose for different protocols with different geometries of exposure in five cone beam CT equipment. For this, a female Alderson anthropomorphic phantom, manufactured by Radiology Support Devices was used. The phantom was irradiated with 26 dosimeters LiF: Mg, Ti (TLD-100), inserted in organs and tissues along the layers forming the head and neck of the phantom. The equipment used, in this present assessment, was: i-CAT Classical, Kodak 9000 3D, Gendex GXCB 500, Sirona Orthophos X G 3D and Planmeca Pro Max 3D. The effective doses were be determined by the ICRP 103 weighting factors. The values were between 7.0 and 111.5 micro Sv, confirming the broad dose range expected due to the diversity of equipment and protocols used in each equipment. The values of effective dose per Fov size were: between 7 and 51.2 micro Sv for located Fov; between 17.6 and 52.0 micro Sv for medium Fov; and between 11.5 and 43.1 micro Sv to large Fov (maxillofacial). In obtaining the effective dose the measurements highlighted a relevance contribution of dose absorbed by the remaining organs (36%), Salivary glands (30%), thyroid (12%) and bone marrow (12%). (Author)

  3. Study of effective dose of various protocols in equipment cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Soares, M. R.; Maia, A. F. [Universidade Federale de Sergipe, Departamento de Fisica, Cidade Universitaria Prof. Jose Aloisio de Campos, Marechal Rondon s/n, Jardim Rosa Elze, 49-100000 Sao Cristovao, Sergipe (Brazil); Batista, W. O. [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho, Salvador, 40301015 Bahia (Brazil); Caldas, L. V. E.; Lara, P. A., E-mail: mrs2206@gmail.com [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    Currently the cone beam computed tomography is widely used in various procedures of dental radiology. Although the doses values associated with the procedures of cone beam CT are low compared to typical values associated with dental radiology procedure in multi slices CT. However can be high compared to typical values of other techniques commonly used in dental radiology. The present scenario is a very wide range of designs of equipment and, consequently, lack of uniformity in all parameters associated with x-ray generation and geometry. In this context, this study aimed to evaluate and calculate the absorbed dose in organs and tissues relevant and estimate effective dose for different protocols with different geometries of exposure in five cone beam CT equipment. For this, a female Alderson anthropomorphic phantom, manufactured by Radiology Support Devices was used. The phantom was irradiated with 26 dosimeters LiF: Mg, Ti (TLD-100), inserted in organs and tissues along the layers forming the head and neck of the phantom. The equipment used, in this present assessment, was: i-CAT Classical, Kodak 9000 3D, Gendex GXCB 500, Sirona Orthophos X G 3D and Planmeca Pro Max 3D. The effective doses were be determined by the ICRP 103 weighting factors. The values were between 7.0 and 111.5 micro Sv, confirming the broad dose range expected due to the diversity of equipment and protocols used in each equipment. The values of effective dose per Fov size were: between 7 and 51.2 micro Sv for located Fov; between 17.6 and 52.0 micro Sv for medium Fov; and between 11.5 and 43.1 micro Sv to large Fov (maxillofacial). In obtaining the effective dose the measurements highlighted a relevance contribution of dose absorbed by the remaining organs (36%), Salivary glands (30%), thyroid (12%) and bone marrow (12%). (Author)

  4. Radiological protection report 2012

    International Nuclear Information System (INIS)

    2013-06-01

    Two years after the massive release of radiation from the nuclear power plants at Fukushima Dai-ichi, the repercussions continue to preoccupy the radiological and emergency protection community, both in Switzerland and internationally. In Switzerland the Swiss Federal Nuclear Safety Inspectorate (ENSI) has initiated measures as part of the European Union Stress Tests and has its own Fukushima Action Plan. In this Annual Report, ENSI focuses on radiological protection in Swiss nuclear facilities. The average individual dose has changed little compared with previous years. At 0.7 mSv, it is significantly below the limit both for persons exposed to radiation during their work (20 mSv) and the annual average rate of exposure for the population in Switzerland as a whole (5.5 mSv). In terms of collective doses, the extensive maintenance work at the Leibstadt power plant (KKL) resulted in a doubling of rates compared with recent years. However, in the remaining nuclear facilities the rates have not changed significantly. The highest individual dose during the year under review was 13 mSv. Exposure rates in 2012 for all those exposed to radiation during work in facilities subject to ENSI surveillance were below the maximum limit. Greater attention is now being given to work in high and variable radiation fields and in difficult conditions. Swiss nuclear facilities continue to operate a consistent radiological protection approach. Measuring equipment plays an important role in radiological protection. Having conducted a range of inspections and comparative measurements of aerosol-iodine filters and waste water sampling together with measurements in the field of personal dosimetry, ENSI has concluded that the required measuring equipment for radiological protection exists, that this equipment is correctly used and provides reliable data. ENSI maintains a test laboratory that analyses samples from nuclear facilities and their immediate vicinity and also conducts field

  5. Radiological protection in dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Holliday, B

    1974-01-01

    Information that would allow an assessment of the standard of radiological protection in dentistry in the United Kingdom is sparse. The National Radiological Protection Board (previously the Radiological Protection Service) has provided a monitoring and advisory service to dentists for many years but very limited use has been made of this service. In a recent survey, 114 dentists were visited in representative practices in South East England and it was established that only 6.5% of dentists in general practice do not use radiography as an adjunct to their practice (Smith, 1969). In the 88 x-ray sets which were examined, 24% had less than the recommended thickness of aluminium filtration, while 25% had a fixed field size which was larger than necessary for dental radiography; in addition, 27% of the timers were found to have an error of greater than 20% in repetition of the pre-set exposure time. The exposure rate at the cone tip of a dental x-ray unit is generally in the range 1 to 4 R/s. A fault in the timer unit coupled with a failure on the part of the dentist to notice that x-rays are being generated (normally indicated by a red warning light) would rapidly lead to excessive exposure of the patient. Furthermore, a dentist continually holding films in the mouth of his patient would certainly incur a dose well in excess of the permissible hand dose, assuming anaverage work load for the x-ray equipment. Three case histories are given to illustrate the type of hazard that might arise from faulty equipment or bad operating technique.

  6. Changes in radiological protection and quality control in Spanish dental installations: 1996-2003.

    Science.gov (United States)

    Alcaraz-Baños, Miguel; Parra-Pérez, María del Carmen; Armero-Barranco, David; Velasco-Hidalgo, Francisco; Velasco-Hidalgo, Esteban

    2009-10-01

    The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection.

  7. X-ray beam qualities for dental radiology purposes

    International Nuclear Information System (INIS)

    Santos, Marcus Aurelio P. dos; Fragoso, Maria da Conceicao de F.; Lima, Ricardo de A.; Hazim, Clovis A.

    2009-01-01

    In order to establish characteristics or properties of equipment for diagnostic radiology, e.g. ion chambers and semiconductor detectors, calibration laboratories offer a set of well-defined radiation conditions, called X-ray qualities, which can be used for many Physics studies and medical purposes. The standardization of radiation qualities has been carried out in several fields of study, but little attention has been given to the area of dental radiology, mainly for medical and physical applications using single-phase units with half-wave rectification. For this reason, a single-phase dental unit with adjustable peak voltage and tube current, called 'variable potential X-ray equipment', was developed aiming to define X-ray beam qualities for test and calibrations purposes. X-ray spectra at 50, 60 and 70 kVp were determined by using a CdTe detector and compared with those obtained for ten commercial X-ray dental units. As a result of this study, a set of X-ray qualities for the variable potential X-ray equipment was determined. The X-ray qualities spectra were utilized as reference for determination of a new set of X-ray qualities characterized for a constant potential X-ray equipment. Thus, sets of X-ray qualities were standardized and implemented in two X-ray laboratories: one with the variable potential X-ray equipment and other with constant potential X-ray equipment. These reference X-ray beam qualities should be used for test and calibration purposes involving scientific studies and services. (author)

  8. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A.; Fernandes, Angela; Westphalen, Fernando Henrique

    2013-01-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  9. Evaluation of the composition of filters additional of equipment radiological intraoral by energy dispersive x-ray fluorescence (EDXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Franca, Alana Caroline; Torres, Catarina A.M.P.; Rocha, Ana S.S.; Deniak, Valeriy; Lara, Alessandro L.; Paschuk, Sergei A., E-mail: alanacarolinef@gmail.com, E-mail: sergei@utfpr.edu.br [Universidade Tecnologica Federal do Parana (CPGEI/UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduacao em Engenharia Eletrica e Informatica Industrial; Fernandes, Angela; Westphalen, Fernando Henrique, E-mail: angelafernandes@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Setor de Ciencias da Saude

    2013-07-01

    The need for high quality standards for radiographic images in order to make a diagnosis assertive, and being the additional filtration required in the intraoral X-ray equipment show the need of evaluating these filters. This study aims to examine the influence of the elemental composition of the filters of X-ray of dental intraoral equipment in the radiographic images quality. The filters analysis were performed by using the energy dispersive X-ray fluorescence method (EDXRF). Ten conventional filters were analysed. In this study, 33 radiographic exposures were performed using films: twenty radiographs in the incisor region and ten in the molar region, three exposures were also made in the same regions with same conditions without using filter. After radiographs development, optical density was measure and all radiographs were submitted to subjective evaluation by dental radiologists. Data obtained were correlated to effects evaluation of the elemental composition of all filters in the quality of the radiographic images. The elements found were: aluminum, cobalt, copper, sulfur, iron, manganese, titanium, zinc, and zirconium. The images obtained were identified in groups: Molars to 0.3 s; Incisors to 0.2 s; Incisors to 0.3 s, and for the group without filters. From the results obtained it was concluded that both unclear radiographs and ideal radiographs were produced by using filters of elementary common. Therefore, conventional filters evaluated were an acceptable option to produce quality images in dental radiology, despite differences in the composition of the alloys. (author)

  10. Room design in dental radiology

    International Nuclear Information System (INIS)

    Achalli, Sonika

    2013-01-01

    Radiography and radiographic examination of the patient form most valuable diagnostic tool in providing comprehensive dental care. The safe and effective use of the X-ray equipment is important for the protection of the patient, other members of the public and all members of the dental team. For patients, the risk that is associated with exposure to X-rays must always be weighed against the clinical benefit of an accurate diagnosis. The risks associated with the exposure to the X-rays during the radiographic examination of the patient must be minimised by meticulously adhering to good practice and thus carefully managing the use of dental radiological procedures. The dentist or the personnel who is the license holder for the X-ray equipment is ultimately responsible for the radiation safety at the workplace. One important method in limiting the possible risk of radiation exposure at workplace is the correct design of an X-ray room. This paper is aimed at discussing the guidelines and recommendations on X-ray room designs in dental radiology in order to facilitate radiation control and safe working conditions for radiation workers as well as the public. (author)

  11. Meios e fins do desenvolvimento para Celso Furtado

    Directory of Open Access Journals (Sweden)

    Fabio Antonio de Campos

    2014-10-01

    Full Text Available O objetivo desse artigo é expor o conceito de desenvolvimento para Celso Furtado. Para tanto, nos interessa apresentar o desenvolvimento nacional como um fim em sua abordagem sobre a formação social brasileira Para atingir tal estágio, os meios para o autor seriam assegurados por um típico desenvolvimento capitalista. Dentro dessa problemática, mostraremos também o alcance e os limites dessa concepção para o caráter dependente e subdesenvolvido do capitalismo brasileiro.

  12. O desafio político do desenvolvimento sustentado

    OpenAIRE

    Guimarães,Roberto P.

    1995-01-01

    A unanimidade que hoje parece haver em favor do desenvolvimento sustentado contrasta com a ausência de iniciativas políticas significativas para transformar as instituições econômicas, sociais e políticas que estão comprometidas com o estilo vigente de desenvolvimento. Em particular, há uma patente contradição entre o discurso antiestatista hegemônico e as exigências do desenvolvimento sustentado, que incluem um Estado ainda mais forte, em suas capacidades reguladoras e de planificação, que o...

  13. An Advanced Radiological Survey and Mapping System

    International Nuclear Information System (INIS)

    McCown, J.; Rogers, D.; Waggoner, Ch.

    2009-01-01

    A variety of radiological surveying systems have been described in the literature. This paper describes relative performances of a system that can employ a variety of radiological sensors including NaI, LiI, and LaBr 3 units of various sizes. The system includes navigation and data collection software that facilitates surveying without the use of survey grid-lines. Parameters presented to the operator via a graphical user interface (GUI) for monitoring system performance and navigation are described. Radiological spectra are logged along with position data from three differential GPS sensors to enhance position accuracy by taking into account the pitch and roll as the survey vehicle moves over uneven terrain. Accuracy of position data increases the potential for, and value of, data fusion with other survey data such as electromagnetic induction images. The survey system described has been developed around a zero turn radius lawn mower equipped with on-board generator/inverter for powering electronic and data communication equipment to maximize surveying effectiveness. Detection limits for U-238 will be discussed for the NaI (FIDLER, 75x75 mm, and 100x100x400 mm) and LaBr 3 (75x75 mm) detectors. These parameters will be reported for a variety of survey speeds (stationary, 1, 2, and 3 m/s), with and without the use of advanced signal processing to increase detection sensitivity. A background subtraction algorithm evaluating each spectrum for the presence of naturally occurring radiological materials will also be described for correcting each datum prior to mapping using Geosoft Oasis montaj. (authors)

  14. Composition and fundamental requirements of nuclear emergency response monitoring equipment

    International Nuclear Information System (INIS)

    Lai Yongfang; Huang Weiqi; Wang Yonghong

    2009-01-01

    Nuclear emergency monitoring equipment is concrete foundation for accomplishing radiation monitoring in nuclear or radiation accidents. Based on technical report: Generic procedures for monitoring in a nuclear or radiological emergency published by IAEA in 1999, this paper presents the main task and composition of nuclear emergency monitoring briefly, and then the basic equipment and trends of nuclear emergency monitoring equipment is put forward in detail, which is useful to construction and reinforcement of our nuclear emergency monitoring. (authors)

  15. Evaluation of radiation protection conditions in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda Saicla; Rocha, Anna Silvia Penteado Setti da, E-mail: miguel_cristianoch@yahoo.com.br [Universidade Tecnologica Federal do Parana (PPGEB/UTFPR), Curitiba, PR (Brazil). Programa de Pos-graduacao em Engenharia Biomedica; Tilly Junior, Joao Gilberto [Universidade Federal do Parana (UNIR/UFPR), Curitiba, PR (Brazil). Hospital de Clinicas. Unidade de Imagem e Radioterapia; Almeida, Claudio Domingues de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Dept. de Fisica Medica

    2016-04-15

    Introduction: The dental radiology represents about 20% of human exposure to radiation in radio diagnostic. Although the doses practiced in intraoral dentistry are considered low, they should not be ignored due to the volume of the performed procedures. This study presents the radiation protection conditions for intraoral radiology in Curitiba - PR. Methods: Data was collected through a quantitative field research of a descriptive nature during the period between September of 2013 and December of 2014. The survey sample consisted of 97 dentists and 130 intraoral equipment. The data related to the equipment was collected using structured questions and quality control evaluations. The evaluations of the entrance skin dose, the size of the radiation field and the total filtration were performed with dosimetry kits provided and evaluated by IRD/CNEN. The exposure time and voltage were measured using noninvasive detectors. The occupational dose was verified by thermoluminescent dosimeters. The existence of personal protection equipment, the type of image processing and knowledge of dentists about radiation protection were verified through the application of a questionnaire. Results: Among the survey's results, it is important to emphasize that 90% of the evaluated equipment do not meet all the requirements of the Brazilian radiation protection standards. Conclusion: The lack of knowledge about radiation protection, the poor operating conditions of the equipment, and the image processing through visual method are mainly responsible for the unnecessary exposure of patients to ionizing radiation. (author)

  16. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Radiological equipment is not purpose-built for each individual application. Thus, not only are acceptance criteria directly related to the design of equipment and the quality assurance exercised during its manufacture, but also the performance, safety and reliability of equipment must feature in the requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. Similarly the continuing reliability of equipment in service is directly related to the quality of maintenance services. This is determined largely by the manner in which such services are procured. In the UK this issue has been considered by one of four Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes the complementary duties of contractors and customers. The use in X-ray departments of the kind of manufacturing quality system that is used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure to patients. (author)

  17. Activity-based cost analysis in catheter-based angiography and interventional radiology

    International Nuclear Information System (INIS)

    Rautio, R.; Keski-Nisula, L.; Paakkala, T.

    2003-01-01

    The aim of this study was to analyse the costs of the interventional radiology unit and to identify the cost factors in the different activities of catheter-based angiographies and interventional radiology. In 1999 the number of procedures in the interventional radiological unit at Tampere University Hospital was 2968; 1601 of these were diagnostic angiographies, 526 endovascular and 841 nonvascular interventions. The costs were analysed by using Activity Based Cost (ABC) analysis. The budget of the interventional unit was approximately 1.8 million Euro. Material costs accounted for 67%, personnel costs for 17%, equipment costs for 14% and premises costs for 2% of this. The most expensive products were endografting of aortic aneurysms, with a mean price of 5291 Euro and embolizations of cerebral aneurysms (4472 Euro). Endografts formed 87.3% of the total costs in endografting and Guglielmi detachable coils accounted for 63.3% of the total costs in embolizations. The material costs formed the majority of the costs, especially in the newest and most complicated endovascular treatments. Despite the high cost of angiography equipment, its share of the costs is minor. In our experience ABC system is suitable for analysing costs in interventional radiology. (orig.)

  18. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology

    International Nuclear Information System (INIS)

    Mori, Hiroshige

    2015-01-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses’ annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units’ pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses. (practical matter)

  19. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    Science.gov (United States)

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  20. Study of graduate curriculum in the radiological science: problems and suggestions

    International Nuclear Information System (INIS)

    Ko, Seong Jin; Kim, Hwa Gon; Kang, Se Sik; Park, Byeong Rae; Kim, Chang Soo

    2006-01-01

    Currently, Educational program of radiological science is developed in enormous growth, our educational environments leading allied health science education program in the number of super high speed medical industry. Radiological science may be the fastest growing technologies in our medical department today. In this way, Medical industry fields converged in the daily quick, the fact that department of radiological science didn't discharged ones duties on current educational environments. The curriculum of radiological technologists that play an important part between skill and occupation's education as major and personality didn't performed one's part most effectively on current medical environments and digital radiological equipment interface. We expect improvement and suggestion to grow natural disposition as studies in the graduate of radiological science. Therefore, in this paper, current curriculum of radiological science are catched hold of trend and problems on digital radiology environments, on fact the present state of problems, for Graduate program of radiological science, graduate courses of MS and ph.D. are suggested a reform measure of major education curriculum introduction

  1. The World Health Organization's Basic Radiological System (WHO-BRS). How to provide a better service with less cost

    International Nuclear Information System (INIS)

    Gomez Crespo, G.; Hanson, G.P.

    1986-01-01

    This article describes the application of the World Health Organization - Basic Radiological System (WHO-BRS) in Latin America in particular in Colombia. Various aspects of the radiological system are discussed including the X-ray equipment, radiation safety, training, manuals for operating and maintenance of the equipments, supply of spare parts, etc. The difficulties encountered in applying medical radiography in Latin America are pointed out. 6 refs

  2. Off-site response for radiological emergencies

    International Nuclear Information System (INIS)

    Eldridge, J.S.; Oakes, T.W.; Hubbard, H.M.; Hibbitts, H.W.

    1982-01-01

    Environmental radiological surveillance under emergency conditions at off-site locations is one of the advisory functions provided by DOE within the ORO jurisdiction. The Department of Environmental Management of ORNL has been requested to provide sampling and analytical assistance at such emergency response activities. We have assembled and identified specific individuals and equipment to provide a rapid response force to perform field measurements for environmental radioactivity releases as a consequence of nuclear accidents. Survey teams for sample collection and field measurements are provided along with analytical assistance to operate the radioactivity measuring equipment in the DOE emergency van

  3. CONHECIMENTO: UM FATOR DE DESENVOLVIMENTO ORGANIZACIONAL

    Directory of Open Access Journals (Sweden)

    Adilson dos Santos Morais

    2017-09-01

    Full Text Available Cada vez mais, criar conhecimento útil para atuar em uma posição de vantagem competitiva, orientado para o desenvolvimento organizacional e valorizando o capital humano tem-se demonstrato uma estratégia eficaz. O presente artigo busca apresentar a importância do conhecimento para o desenvolvimento das organizações em âmbito geral com destaque para as comunidades de prática. Esse conhecimento é derivado das interações desenvolvidas em processos de aprendizagem que ocorrem no ambiente organizacional. Para este, realizou-se um estudo teórico, descritivo, que tem como procedimento a pesquisa bibliográfica. Deste modo, apresenta como resultado deste trabalho a evidência de que existem poucos resultados divulgados sobre retorno financeiro e os benefícios dos investimentos realizados no capital intelectual humano pelas organizações. Porém, o conhecimento agrega valor à organização aumentando o valor do capital intelectual e as literaturas sobre o conhecimento e desenvolvimento organizacional consideram o capital intelectual o fator chave para a melhoria nos sistemas estratégicos. Destaca-se que esta contribuição poderá instigar cada vez mais a criação de conhecimento como fator de reconhecimento humano e de desenvolvimento das organizações.

  4. Document: the radiological survey of the environment

    International Nuclear Information System (INIS)

    Gerno, Linden; Leprieur, F.; Janssens, A.

    2002-01-01

    The document presents the radiological survey of the environment in France today with a comparison of the situation in Switzerland, Germany and Belgium. The evolution of the policy in this activity is also concerned. The laboratories and their monitoring equipment, the regulation and the social impacts are discussed. (A.L.B.)

  5. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  6. Desenvolvimento e sociologia: uma aproximação necessária

    Directory of Open Access Journals (Sweden)

    Alessandro André Leme

    2015-08-01

    Full Text Available ResumoO debate acerca do desenvolvimento na América Latina e no Brasil em particular revelou-se como um dos temas proeminentes do pensamento sociopolítico e econômico brasileiro. As interpretações do Brasil a partir da temática do desenvolvimento ganham força a partir da década de 1930, porém, será após a Segunda Guerra Mundial, com a intensificação da industrialização e a modernização da sociedade capitalista brasileira, que o tema adquire centralidade na sociologia/ciência política. Por outro lado, as discussões acerca do Estado e do desenvolvimento estão intimamente ligadas ao desenvolvimento do capitalismo brasileiro, ou seja, configura uma tríade que simultaneamente evidencia tanto um tipo historicamente determinado de Estado como um tipo particular de desenvolvimento econômico e social do país. O desenvolvimento do Brasil caracteriza-se por um embate entre o mercado e o Estado, sendo a influência desse último fundante para o padrão de desenvolvimento pretendido no país. Propomos a análise do processo de desenvolvimento como forma de revisitar o debate teórico e conceitual produzido sobre a temática no país, assim como investigar o movimento histórico, econômico e político adotado pelo Brasil como estratégia para o desenvolvimento nos anos 1990.

  7. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  8. Diagnóstico auxiliado por computador na radiologia Computer-aided diagnosis in radiology

    Directory of Open Access Journals (Sweden)

    Paulo Mazzoncini de Azevedo-Marques

    2001-10-01

    Full Text Available Vários desenvolvimentos tecnológicos estão convergindo de forma a aumentar a influência da área de imagens nas pesquisas biomédicas e na medicina clínica. Muitos pesquisadores têm trabalhado no desenvolvimento de sistemas computadorizados para detecção automatizada e quantificação de anormalidades em imagens radiológicas. Estes sistemas são dedicados ao diagnóstico auxiliado por computador. Este artigo discute os conceitos básicos relacionados ao diagnóstico auxiliado por computador e apresenta uma revisão bibliográfica sobre o assunto.Several technological developments are contributing to increase the use of imaging techniques in biomedical research and clinical medicine. Many investigators have attempted to develop computerized routines for automated detection and quantitative analysis of abnormalities in radiological images. These routines have been referred to as computer-aided diagnosis. In this paper we discuss the basic concepts of computer-aided diagnosis and review the literature.

  9. O “Bê-Á-Bá” da Aprendizagem Baseada em Equipe

    Directory of Open Access Journals (Sweden)

    Rodrigo de Rosso Krug

    Full Text Available RESUMO A Aprendizagem Baseada em Equipe (ABE é uma estratégia educacional que tem sido empregada na educação de profissionais de saúde para o desenvolvimento de competências fundamentais, como a responsabilização do aluno pela aquisição do próprio conhecimento, a tomada de decisão e o trabalho colaborativo e efetivo em equipe. Levando em consideração que, no Brasil, poucos artigos nacionais explicam como realizar esta estratégia educacional, o objetivo deste artigo foi descrever os conceitos, os princípios, o planejamento e o processo detalhado para aplicação da ABE.

  10. A study of professional competence for radiological technology department students in Taiwan area

    International Nuclear Information System (INIS)

    Cheng Kai-Yuan; Hsieh Bor-Tsung; Huang W.

    2005-01-01

    Recently, so many medical institutions established and the increasing use of the high technological medical imaging equipment, it makes radiological technology become the main instrument for the medical diagnostic and radiation therapy. However, the medical radiological technologies play the important role to operate all the related radiological machines. If they do not use the machines adequately, it will increase the patients' radiation absorbed dose. Then, the whole society health may be influenced. Therefore, constructing the professional competence of the medical radiological technologists is an important course. The purpose of this research are: (1) to construct the index of professional competence with radiological technology students, (2) to discuss the professional competence for the graduates from the department of radiological technology to be the reference for the Ministry of Examination for the license test of radiological technologists, (3) to provide the direction of the radiological technology department development. (author)

  11. Training courses for radiological technicians: radiation protection of the patient and control of image quality

    International Nuclear Information System (INIS)

    Mateus Yoshimura, Elisabeth; Costa, Paulo Roberto; Furquim, Tania Aparecida; Freitas, Marcelo Baptista de; Valente, Marcelo; Cerri, Giovanni Guido

    2008-01-01

    Full text: As in other countries, life expectancy is increasing in Brazil, and the number of radiological examinations tends to increase. Old equipment and high technology ones cohabit, radiology technicians are not well prepared to conduct practices, images and doses to patients are not optimized. Digital techniques that began to be introduced in the last years are also an important issue, because, as it is possible to modify the image digitally, there is less concern about the choice of equipment parameters that produce the best-image/lowest-dose compromise. Pediatric radiology, CT and fluoroscopy require attention too, as they are of dosimetric interest or because the patient ages imply higher risks or because the techniques deliver higher doses than the conventional ones. In our opinion, the most important role that we can play is educating and forming people to work in this area: training programs and refreshing courses are a way of facing the problem. This way, we are organizing, in a technical cooperation with IAEA, two training courses in quality assurance and radiation protection in radiology, one designed to physicists (60 h), and the radiological technicians (40 h). An important cooperation with a paediatric and a general hospital made it possible to offer courses with 50% practical lessons, performed both in the University and in hospital equipment. Both courses cover a basic Radiation Physics program, radiation protection, image formation and quality control in conventional and digital equipment, and patient dosimetry. Equipment donated by IAEA facilitate the practical QA and dosimetry lessons. The rationale of our project is making it sustainable through the formation of physicists that will go on in the education process of technicians in technical schools. We present the results of the first two courses (physicists and technicians), considering the selection process, the development of the activities, and the assessment both of the students enrolled

  12. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  13. The use of Leeds Test Objects in the assessment of the performance of radiological imaging systems: an introduction

    International Nuclear Information System (INIS)

    Cowen, A.R.

    1986-01-01

    Over the preceding decade the Leeds Radiological Imaging Group have developed a range of test objects with which to assess the performance of radiological imaging systems. The types of imaging equipment which can be assessed include X-ray image intensifier television systems, small-format 100mm/105mm fluorography systems and radiographic screen-film combinations. We have recently extended our interest to the evaluation of digital radiological imaging equipment including digital subtraction fluorography and digital (greyscale) radiographic imaging systems. These test objects were initially developed for the purpose of evaluating imaging performance under laboratory conditions but they have also proved useful under field (clinical) conditions. (author)

  14. Liderança e trabalho em equipe: um estudo de caso da equipe de enfermagem de um hospital geral de Belo Horizonte http://dx.doi.org/10.15601/1983-7631/rt.v2n3p83-94

    Directory of Open Access Journals (Sweden)

    Karla Rona Silva

    2011-12-01

    Full Text Available O trabalho em equipe é considerado um importante pressuposto para a reorganização do processo de trabalho. Essa modalidade visa uma abordagem mais integral, resolutiva e efetiva frente às atividades coletivas e interdisciplinares. Para a equipe de enfermagem este tipo de trabalho é de fundamental importância e depende de uma liderança capaz de gerenciar os conflitos e anseios que por ventura surgirem. Tal liderança, muitas vezes, eleita pelo próprio grupo, envolve a capacidade de influenciar pessoas. Assim, esse estudo tem por objetivo analisar o papel das lideranças e sua efetividade para o trabalho no interior de uma equipe assistencial de enfermagem. Os sujeitos da pesquisa em questão são quatro técnicos de enfermagem do setor de atendimento de urgência e emergência de um hospital geral de grande porte, localizado em Belo Horizonte. Uma vez que a questão da liderança apresenta-se, na maioria das vezes, de forma subjetiva, não sendo possível analisá-la em sua plenitude em questionários fechados, optou-se pela utilização da observação participante como principal ferramenta metodológica para coleta dos dados da pesquisa. Com o estudo, pode-se observar que a equipe, de uma forma geral, possui um bom entrosamento e uma postura ético-profissional pertinente ao desenvolvimento da assistência e do cuidado frente ao paciente. No entanto, a observação participante nos revelou a existência de uma liderança autoritária exercida por um dos membros da equipe. Apesar da insatisfação gerada nos demais membros da equipe, essa postura não prejudica o desenvolvimento do trabalho.Palavras-chave: equipe; liderança; enfermagem

  15. Protective equipment of radiological protection and the worker wear; Equipamento de protecao radiologica e o desgaste do trabalhador

    Energy Technology Data Exchange (ETDEWEB)

    Cassia, Flor Rita de; Huhn, Andrea, E-mail: flor@ifsc.edu.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Santa Catarina (IFSC), Florianopolis, SC (Brazil); Lima, Gelbcke Francine, E-mail: fgelbcke@ccs.ufsc.br [Universidade Federal de Santa Catarina (PEN/UFSC), Florianopolis, SC (Brazil). Programa de Pos-Graduacao em Enfermagem

    2013-11-01

    This qualitative research with workers of seven hemodynamic service of Santa Catarina, Brazil aimed to analyze the use of radiological protection equipment (RPE), as well as wear to the health of workers who use these causes. The study was conducted between March 2010 and November 2010, totaling approximately 30 hours of observations. Results showed resistance to the use of RPE and also showed wear to workers' health, mainly due to the weight and discomfort they cause, as may weigh 7-9 pounds, depending on the model used. Evidenced also the absence of workers due herniated disc, back pain, and other musculo skeletal problems. These complaints, in addition to being related to the use of these protective gear also related with the time that workers remain standing for long periods on certain procedures, such as angioplasty. Given these results, the research recommended the use of these devices with materials, that are already being produced, making lighter aprons, thus avoiding fatigue and back pain and also provide greater comfort by reducing workers' resistance to its use and its adverse consequences.

  16. Guidelines on radiology standards for primary dental care

    International Nuclear Information System (INIS)

    1994-01-01

    A Joint Working Party (JWP) on patient dose reduction in diagnostic radiology was established between the Royal College of Radiologists (RCR) and the National Radiological Protection Board (NRPB) towards the end of 1988. JWP identified a large potential for patient dose reduction on a national scale, and a report of its findings was published in 1990. This guidance was only generally applicable to dental radiology and in 1992 a further joint venture between RCR and NRPB resulted in the formation of a Working Party (WP) to consider all aspects of dental radiology applicable to primary dental care. Dental radiology is one of the largest single groups of radiographic examination performed, although the effective dose per radiograph is small. This means that individual risks from dental radiology are low, but WP has identified a significant potential for reduction in the collective dose and for improvements in the diagnostic quality of radiographs. The WP recommendations cover all aspects of dental radiology: training and examination regimes for dentists and staff, patient selection and clinical justification for radiography, diagnostic interpretation, equipment and procedural aspects, and finally the question of quality assurance in dental radiology. The economic impact of the many recommendations by WP has been considered in some detail. The benefits and cost of each recommendation either have been assigned a monetary value or have been assessed more qualitatively. The conclusion is that there is a strong economic justification for implementation of the full package of recommendations. (Author)

  17. Radiological risks in an operational environment

    International Nuclear Information System (INIS)

    Castagnet, X.; Lafferrerie, C.; Amabile, J.C.; Cazoulat, A.; Laroche, P.

    2010-01-01

    A radiological hazard (e. g. a detonating dirty bomb or accidental radionuclide dispersion) leading to a large number of contaminated or irradiated people needing immediate medical assistance is one of the main threats our troops deployed in an operational environment are facing. Immediate first aid anyway shall take precedence over decontamination but the unique nature of these injuries necessitates specific medical knowledge and training. A contaminated victim needs a rapid -clinical physical and biological- medical evaluation which will determine the amount of required medical support. A person with external contamination needs to be rapidly cleansed to limit spreading surface burns as well as limiting the possible contamination internally spreading into the body. A person with internal contamination requires rapid decontamination at the wound point and antidotes to internally cleanse the body. In France, the Military Health Service has developed a centre of expertise at the Percy military hospital near Paris which is geared up to deal with the victims of radiological attacks. It also has a mobile laboratory equipped with full radio toxicology equipment and body dosimeters to enable rapid and effective results when required. (authors)

  18. CERVEJA ARTESANAL E DESENVOLVIMENTO REGIONAL EM SANTA CATARINA (BRASIL)

    OpenAIRE

    Valdinho Pellin; Oklinger Mantovaneli Jr.

    2016-01-01

    Discussões relacionadas ao fortalecimento do desenvolvimento regional tem estimulado um debate em relação a contribuições que Indicações Geográficas (IGs) podem oferecer ao desenvolvimento. IGs se constituem em elemento de identificação de produtos ou serviços com seus territórios e podem oferecer contribuições importantes para o desenvolvimento regional, agregando valor aos produtos, facilitando o acesso a novos mercados e valorizando tradições locais. Este artigo procura discutir a importân...

  19. Panoramic radiology. Seminars on maxillofacial imaging and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Farman, Allan G. (ed.) [Louisville Univ., KY (United States). Dept. of Surgical and Hospital Dentistry

    2007-07-01

    Complete up-to-date collection of information on panoramic radiography usage. Up-to-date terminology validated by representatives of individual special disciplines within dentistry. Each chapter with educational objectives and review questions. Panoramic radiology systems are currently being used in more practices than at other any time in the past. The practitioner now has decisions to make regarding detector technology selection for image acquisition and must remain informed about appropriate usage. This book is applicable to all panoramic dental images and equipment. It approaches panoramic radiology usage in the context of general and specialty applications. (orig.)

  20. Designing of a mobile decontamination facility (MDF) for preparedness and response to nuclear/radiological emergencies

    International Nuclear Information System (INIS)

    Joshi, G.H.; Garai, S.K.; Chatterjee, M.K.; Pradeepkumar, K.S.; Sharma, D.N.

    2005-01-01

    During a radiological emergency in public domain, likelihood of radioactive contamination cannot be completely ruled out. Timely and effective decontamination can significantly reduce possible external and internal radiation exposure to public. The objective of designing of a mobile decontamination facility is to develop the capability for decontaminating affected persons in case of any radiological emergency in public domain. A fully equipped decontamination facility on the wheels will be able to reach at the scene and will be able to decontaminate a large number of victims with the help of optimized decontamination procedures in short duration avoiding unwanted radiation exposure. This self-supporting decontamination facility is designed to be equipped with sufficient number of radiation monitoring instruments, equipments for decontamination, decontamination agents etc. (author)

  1. Is Your Interventional Radiology Service Ready for SARS?: The Singapore Experience

    International Nuclear Information System (INIS)

    Lau, Te-Neng; Teo, Ngee; Tay, Kiang-Hiong; Chan, Ling-Ling; Wong, Daniel; Lim, Winston E.H.; Tan, Bien-Soo

    2003-01-01

    The recent epidemic of severe acute respiratory syndrome caught many by surprise. Hitherto, infection control has not been in the forefront of radiological practice. Many interventional radiology (IR) services are therefore not equipped to deal with such a disease. In this review, we share our experience from the interventional radiologist's perspective, report on the acute measures instituted within our departments and explore the long-term effects of such a disease on the practice of IR

  2. Studies on optimization of radiation protection for patients in diagnostic radiology

    International Nuclear Information System (INIS)

    Wei, Z.; Zhang, Q.; Li, W.; Li, K.; Wei, L.; Zong, X.; Qiang, Z.; Wu, Y.

    1994-01-01

    For the exposure of patients in diagnostic radiology, individual dose limit does not apply, but optimization of radiological protection may play a major role. This project has been carried out with the purpose of improving the protection of patients in medical diagnostic radiology in China utilizing the principles of optimization. Taking Sichuan, Shandong and Beijing as surveyed areas, we investigated the present situation of the protection of patients. In the survey, the patient doses were classified into practical dose, justified dose and optimized dose to evaluate the influences of managerial and equipment factors separately. The results show that there are some urgent protection problems in X-ray protection to be solved in the surveyed regions. This paper, however, points out that the prospects of reducing patient doses are encouraging provided that appropriate measures are adopted. For instance, taking proper managerial measures without radical change of existing equipments may reduce patient doses in chest fluoroscopy and radiography by 40% and 18% respectively; refitting some equipment may reduce the doses by 82.4% in chest fluoroscopy, 66% in chest radiography, and 80% in barium meal examination of the gastrointestinal (GI) tract. Using chest radiography instead of fluoroscopy supplemented by other protection measures may reduce the doses by 91.7%. Optimization analysis shows that adoption of the above measures conforms to the principle of optimization of radiation protection. (authors). 5 refs., 7 tabs

  3. Rede de Protagonismo Local para o Desenvolvimento Global

    DEFF Research Database (Denmark)

    Weber, Ángela; Hermann, Roberto Rivas

    Este artigo pretende fazer uma reflexão sobre metodologia a ser desenvolvida e utilizada num projeto de desenvolvimento local, através das ações protagonizadas pela própria comunidade. Para isso parte de uma discussão sobre o conceito de desenvolvimento sustentável, e a seguir propõe a busca de f...

  4. Contrast media properties in interventional radiology

    International Nuclear Information System (INIS)

    Laerum, F.; Enge, I.

    1989-01-01

    Potential hazards of the use of contrast media (CM) in interventional radiology are analyzed by looking into each procedure regarding interactions of CM with pharmaceutical additives, with technical equipment possibly affecting CM stability, and special local or systemic demands related to the procedure. Also the impact of these factors upon the physiological mechanisms are taken into account. (H.W.). 32 refs.; 4 figs.; 2 tabs

  5. International Society of Radiology and Radiation Protection

    International Nuclear Information System (INIS)

    Standertskjoeld-Nordenstam, C.G.

    2001-01-01

    The purpose of the International Society of Radiology (ISR), as being the global organization of radiologists, is to promote and help co-ordinate the progress of radiology throughout the world. In this capacity and as a co-operating organization of the IAEA, the ISR has a specific responsibility in the global radiological protection of patients. Globally, there are many users of medical radiation, and radiology may be practised in the most awkward circumstances. The individuals performing X ray studies as well as those interpreting them may be well trained, as in industrialized parts of the world, but also less knowledgeable, as in developing areas. The problems of radiological protection, both of patients and of radiation workers, still exist, and radiation equipment is largely diffused throughout the world. That is why a conference like this is today as important as ever. Radiation protection is achieved through education, on the one hand, and legislation, on the other. Legislation and regulation are the instruments of national authorities. The means of the ISR are education and information. Good radiological practice is something that can be taught. The ISR is doing this mainly through the biannual International Congress of Radiology (ICR), now arranged in an area of radiological need; the three previous ICRs were in China, in India and in South America; the next one is going to be in Mexico in 2002. The goal of the ICR is mainly to be an instructive and educational event, especially designed for the needs of its surrounding region. The ISR is aiming at producing educational material. The International Commission on Radiological Education (ICRE), as part of the ISR, is launching the production of a series of educational booklets, which also include radiation protection. The ICRE is actively involved in shaping and organizing the educational and scientific programme of the ICRs

  6. Laboratory Accreditation and the Calibration of Radiologic Measuring Tools

    International Nuclear Information System (INIS)

    Vancsura, P.; Kovago, J.

    1998-01-01

    In this paper is presented that accreditation in our days is a strict requirement for a lab for its results could be accepted on international level. Accreditation itself brings to new requirements, among them some are related to the calibration of the radiological measuring equipment

  7. Radiation protection in radiology services in the municipality of Sao Paulo, SP, Brazil; Protecao radiologica nos servicos de radiologia do Municipio de Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Senise, Paulo H.; Silva, Ezequiel; Ruzene, Anderson A.; Braga, Adriano C.; Spirgatis, Armim, E-mail: paulo.senise@fidi.org.br, E-mail: ezequieI.siIva@fidi.org.br, E-mail: anderson.ruzene@fidi.org.br, E-mail: adriano.braga@fidi.org.br, E-mail: armim.spirgatis@fidi.org.br [Fundacao lnstituto de Pesquisa e Estudo de Diagnostico por Imagem (FIDI), Sao Paulo, SP (Brazil); Medeiros, Regina B., E-mail: regina.bitelli@fidi.org.br [Instituto de Pesquisa e Ensino em Medicina Diagnostica e Terapeutica (IPmed), Sao Paulo, SP (Brazil)

    2013-10-01

    The FIDI company providing service to local health care system is responsible for managing part of the services diagnostic imaging of Sao Paulo in the South and Southeast ( 60 % ), Eastern ( 20 % ) and Midwest (20 %), Brazil. The generation of images in the municipal net is performed in conventional manner. Since 2009 works a maintenance associated with the verification of the performance of radiological equipment (annual) and processing (monthly) one. In 2008, on the occasion of the agreement between the city hall and FIDI, conditions were evaluated for radiological protection in 52 care units of the municipality. Were carried out verification tests of performance in conventional equipment, mammographic and tomographic equipment, in 138 and 71 analog processors, according to current legislation. In 2008 , 33 % of the devices had technical problems that prevented its operation. Currently only 3.4 % of the 91 are in radiological equipment maintenance. In 2008 the majority of radiological equipment had more than 10 years of manufacturing, while today fixed equipment have been replaced by new ones and therefore the use of mammography and generally have 2 to 3 years of manufacture . Currently the 31 processors are operative in 2008, 28 % were out of order. The replacement of most of the equipment associated with program quality and preventive/corrective maintenance has kept the service in accordance with the law. (author)

  8. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  9. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  10. French days of radiology (J.F.R.) 2005; Journees francaises de radiologie (JFR) 2005

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Five parts are presented, the nuclear safety authority informs the radiologists on the evolution of the regulation in radiation protection and its practical application; statements of medical and dental radiodiagnosis equipments; licensing for use of radiodiagnosis installation; to use the diagnosis reference levels in radiology to optimize the practices; radiation protection in interventional radiology. (N.C.)

  11. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    Science.gov (United States)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; de-la-Mora, R.; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-10-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services.

  12. Evaluation of mammography equipment performance, dose and image quality in five Latin American countries

    International Nuclear Information System (INIS)

    Brandan, M.-E.; Ruiz-Trejo, C.; Caspani, C. E. M.; Fleitas, I.; Mora, R. de la; Miranda, A. A.; Plazas, M.-C.; Betancourt, C.-M.; Borras, C.

    2001-01-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of radiology experts. We present preliminary results from mammographic imaging facilities. Evaluation of the equipment performance and dose measurements in 21 mammographic units show that, on the average, 75% of the units comply with recommendations issued by various organizations. An independent evaluation of the quality of the clinical images show strong variations among the different radiological services

  13. Manual for environmental radiological surveillance

    International Nuclear Information System (INIS)

    Sumiya, Shuichi; Matsuura, Kenichi; Nakano, Masanao; Takeyasu, Masanori; Morisawa, Masato; Onuma, Toshimitsu; Fujita, Hiroki; Mizutani, Tomoko; Watanabe, Hajime; Sugai, Masamitsu

    2010-03-01

    Environmental radiation monitoring around the Tokai Reprocessing Plant has been conducted by the Nuclear Fuel Cycle Engineering Laboratories, based on 'Safety Regulations for the Reprocessing Plant of JAEA, Chapter IV - Environmental monitoring' and Environmental Radiation Monitoring Program decided by the Ibaraki prefectural government. The radiation monitoring installations and equipments were also prepared for emergency. This manual describes; (1) the installations of radiological measurement, (2) the installations of meteorological observation, and (3) environmental data processing system for executing the terrestrial environmental monitoring by Environmental Protection Section, Radiation Protection Department. The environmental monitoring has been operated through the manual published in 1993 (PNC TN8520 93-001). Then the whole articles were revised because the partially of installations and equipments having been updated in recent years. (author)

  14. Da revolução verde ao discurso do PRONAF: a representação do desenvolvimento nas políticas públicas de desenvolvimento rural no Brasil

    Directory of Open Access Journals (Sweden)

    Michell Leonard Duarte de Lima Tolentino

    2016-12-01

    Full Text Available Este trabalho procura refletir acerca das várias representações de desenvolvimento que embasam algumas das políticas públicas de desenvolvimento rural no Brasil, partindo das representações de desenvolvimento subjacentes à Revolução Verde e focando, posteriormente, no discurso do Programa Nacional de Fortalecimento da Agricultura Familiar (PRONAF. O trabalho se embasa em uma ampla pesquisa bibliográfica e documental. De início abordamos o discurso do desenvolvimento de forma crítica, para logo depois atentarmos para a maneira como este coloca o espaço rural. Para tanto utilizamos autores como Esteva (2000, Escobar (2000, Santos (1979 e Montenegro Gómez (2006. Posteriormente analisamos a Revolução Verde “brasileira” compreendendo o fordismo enquanto seu principal modelo de desenvolvimento. Em seguida, partimos para uma reflexão mais profunda sobre o PRONAF. O PRONAF assume fundamental importância nesse trabalho, pois o entendemos enquanto uma política de extrema relevância para se ler esse momento de inflexão das políticas públicas para o campo, de mudança nas representações sobre o espaço rural e o desenvolvimento rural brasileiro. Ao nos determos no PRONAF, discutimos a mudança de um modelo de desenvolvimento fordista para um modelo de desenvolvimento flexível.

  15. Radiological Assistance Program, DOE Region 6 response plan

    International Nuclear Information System (INIS)

    Jakubowski, F.M.

    1993-02-01

    This program plan meets all the requirements identified in DOE Order 5530.3, Radiological Assistance Program and supports those requirements leading to the establishment of a Federal Radiological Monitoring and Assessment Center (FRMAC) as required by DOE 5530-5. Requests for radiological assistance may come from other DOE facilities, Federal or state agencies, tribal officials, or from any private corporation or individual. Many of the requests will be handled by a telephone call, a conference or a letter, teletype or memorandum. Other requests for assistance may involve radioactive material in serious accidents, fire, personal injuries, contamination or possible hazards to the general public. Some occurrences may require the dispatch of trained personnel equipped with radiation monitoring instruments and related equipment necessary to evaluate, control and neutralize the hazard. The primary responsibility for incidents involving radioactive material always remains with the party having custody of the radioactive materials. In addition, the DOE recognizes that the assistance provided shall not in any way preempt state, tribal, or local authority and/or responsibility on state or tribal properties. Toward this end, DOE assistance for non-DOE radioactive materials, is limited to technical assistance, advice, measurement and other resources as deemed necessary by the local authorities but excludes DOE interface with the public media. This is a function handled by the local or state Incident Commander

  16. Dose assessment in radiological accidents

    International Nuclear Information System (INIS)

    Donkor, S.

    2013-04-01

    The applications of ionizing radiation bring many benefits to humankind, ranging from power generation to uses in medicine, industry and agriculture. Facilities that use radiation source require special care in the design and operation of equipment to prevent radiation injury to workers or to the public. Despite considerable development of radiation safety, radiation accidents do happen. The purpose of this study is therefore to discuss how to assess doses to people who will be exposed to a range of internal and external radiation sources in the event of radiological accidents. This will go a long way to complement their medical assessment thereby helping to plan their treatment. Three radiological accidents were reviewed to learn about the causes of those accidents and the recommendations that were put in place to prevent recurrence of such accidents. Various types of dose assessment methods were discussed.(au)

  17. PROPOSTA TEÓRICO-CONCEITUAL DE DESENVOLVIMENTO EM ARRANJOS PRODUTIVOS LOCAIS

    Directory of Open Access Journals (Sweden)

    Adriana Valélia Saraceni

    2013-04-01

    Full Text Available O objetivo central deste trabalho foi evidenciar algumas ferramentas para o desenvolvimento da inovação e verificar a relação com a configuração do desenvolvimento em Arranjos Produtivos Locais (APLs. Esta pesquisa pode ser considerada como exploratória e descritiva, pois envolve levantamento bibliográfico e análise de exemplos que estimulem a compreensão. Estudos sobre ferramentas de inovação tecnológica e referencias do desenvolvimento de ecossistemas industriais, foram utilizados buscando demonstrar uma proposta teórico-conceitual de integração das ferramentas. Por meio do resultado obtido com a aplicação da metodologia e do referencial teórico, verificou-se que aplicação das ferramentas de inovação tecnológica e a operacionalização com a implantação de métodos e ações cooperadas, tende a fortalecer o desempenho do processo de inovação do arranjo produtivo. A aplicação do conceito de ecologia industrial no desenvolvimento ambientalmente sustentável do aglomerado tende a fortalecer não só o desenvolvimento do APL, como também o desenvolvimento econômico e regional.

  18. Radiological diagnosis in traumatology

    International Nuclear Information System (INIS)

    Frahm, R.

    2001-01-01

    This loose-leaf publication covers all radiological problems that may possibly occur in accident surgery. The focus is on conventional radiological diagnosis. The physical and technical fundamentals of diagnostic examination methods are discussed, followed by practical hints on radiation protection, technical equipment and quality assurance, as well as accurate information on the procedure of taking and interpreting standard X-ray pictures. The indications for standard X-raying, tomography, CT and MRT are presented in consideration of the radiation exposure incurred by the patient. The reader is also informed on the dynamics and varying morphology of bone fracture healing, potential disturbances of callus formation and reconstruction, as well as on possible complications. The main section of the book discusses injuries of the skull, spinal cord, pectoral girdle, upper arm, elbow and lower arm, wrist and hands, pelvis, hip joint, knee and upper and lower leg, ankle joint and foot, thorax and abdomen. (orig.)

  19. Quality assurance program in diagnostic radiology

    International Nuclear Information System (INIS)

    Yacovenco, Alejandro; Borges, J.C.

    1994-01-01

    Aiming to elaborate a methodology to optimize the performance of the Radiology Service of the Military Police Hospital, in Rio dee Janeiro, some goals were established: improvement of the attendance to patients; improvement of the qualification of technicians; achievement and maintenance of high degrees of quality in each step of the radiological process; improvement of the image quality; optimization of dose per examination and cost reduction. The procedure used to detect faults in the radiological process was the analysis of causes of film losses. Results show a 70% reduction in the film rejection rate. 74% of total identified faults were due to equipment, 11% to films, 10% to patients and 5% to developing. The reduction in the cost of developed film reached 75%. A training course given to the staff of the radiological service fully reached its goals, contributing, with the staff motivation, mostly to the success of the program. This success indicates that, with a serious persistent work, it is possible to offer to patients services within their expectations, even at a public hospital. Such programs should be supported by health authorities, not only due to their technical and economic needs but, mostly, due to their social implications. (author). 10 refs., 11 figs

  20. A importância da equipe interdisciplinar no diagnóstico de dislexia do desenvolvimento: relato de caso The importance of interdisciplinary staff in the diagnosis of developmental dyslexia: case report

    Directory of Open Access Journals (Sweden)

    Magda S. Vanzo Pestun

    2002-06-01

    Full Text Available Descrevemos o trabalho de uma equipe interdisciplinar da FCM/UNICAMP na avaliação de um menino de 9 anos e 3 meses aluno de escola pública de Campinas, com dislexia do desenvolvimento. O procedimento constou de 4 fases: 1 anamnese com a mãe; 2 avaliação neuropsicológica; 3 avaliação específica de leitura e escrita; 4 exames complementares. Os resultados das várias avaliações revelaram que o menino apresenta inteligência normal, ausência de déficit auditivo ou visual mas dificuldades em provas específicas de leitura, em memória de curto prazo (especialmente em sequências auditivas e em consciência fonológica, além de lentidão, falta de concentração, sinais neurológicos menores e hipoperfusão da porção mesial do lobo temporal. Esses dados sugeriram que a criança apresenta dislexia do desenvolvimento do tipo misto, necessitando de intervenção psicopedagógica.We describe the work of the interdisciplinary staff of FCM/UNICAMP for the diagnosis of developmental dyslexia, evaluating a 9 years old boy from the second year of a first grade public school. The procedure consisted of four stages: 1 Interview with the mother (anamnesis; 2 neuropsychological evaluation; 3 specific evaluation for reading and writing skills; 4 complementary exams. The results revealed that the child presented normal intelligence, normal auditory and visual function but difficulties in reading specific test, in auditory short-term memory (specially in auditory sequences, and in phonological conscience, as well as slowness, lack of concentration, slight neurological signs and hypoperfusion of the mesial portion of the temporal lobe. These data suggest that the child has developmental dyslexia of mixed type, requiring psychopedagogic follow-up.

  1. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  2. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  3. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  4. Current state of commercial radiation detection equipment for homeland security applications

    International Nuclear Information System (INIS)

    Klann, R.T.; Shergur, J.; Mattesich, G.

    2009-01-01

    With the creation of the U.S. Department of Homeland Security (DHS) came the increased concern that terrorist groups would attempt to manufacture and use an improvised nuclear device or radiological dispersal device. As such, a primary mission of DHS is to protect the public against the use of these devices and to assist state and local responders in finding, locating, and identifying these types of devices and materials used to manufacture these devices. This assistance from DHS to state and local responders comes in the form of grant money to procure radiation detection equipment. In addition to this grant program, DHS has supported the development of American National Standards Institute standards for radiation detection equipment and has conducted testing of commercially available instruments. This paper identifies the types and kinds of commercially available equipment that can be used to detect and identify radiological material - for use in traditional search applications as well as primary and secondary screening of personnel, vehicles, and cargo containers. In doing so, key considerations for the conduct of operations are described as well as critical features of the instruments for specific applications. The current state of commercial instruments is described for different categories of detection equipment including personal radiation detectors, radioisotope identifiers, man-portable detection equipment, and radiation portal monitors. In addition, emerging technologies are also discussed, such as spectroscopic detectors and advanced spectroscopic portal monitors

  5. Radiation hazards and protection of patient in diagnostic radiology

    International Nuclear Information System (INIS)

    Agarwal, Y.C.; Haldar, P.K.

    1980-01-01

    Biological radiation effects such as somatic certainty effects, somatic stochastic effects and genetic effects are described. Diagnostic radiology, therefore, involves risk to the patient in case of undesirable exposures and in particular to the fetus. Gonad doses in diagnostic radiology which may lead to genetic effects have been found to vary within a wide range. To avoid somatic certainty and to keep genetic effects to a minimum, some suggestions are enumerated. They deal with the choice of technique, proper positioning, use of calibrated equipment and use of techniques like xerography, ultrasonography, thermography etc. (M.G.B.)

  6. Tasks of physicists and graduated engineers in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1987-01-01

    The tasks of physicists and engineers in diagnostic radiology are compiled and trends of development are discussed. Specific duties can be selected from these tasks for each department and physicist individually. An attempt is made to characterize the specific tasks of medical physics. The most important tasks are concerning subjects of (1) investment planning, (2) quality control and quality assurance, (3) service and maintenance, (4) radiation protection and electrical safety, (5) development, testing and adaption of equipment, (6) assistance in running the radiologic department, (7) research, (8) pre- and postgraduate training, (9) educational training, (10) miscellaneous. (author)

  7. Radiological protection report 2012; Strahlenschutzbericht 2012

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-06-15

    Two years after the massive release of radiation from the nuclear power plants at Fukushima Dai-ichi, the repercussions continue to preoccupy the radiological and emergency protection community, both in Switzerland and internationally. In Switzerland the Swiss Federal Nuclear Safety Inspectorate (ENSI) has initiated measures as part of the European Union Stress Tests and has its own Fukushima Action Plan. In this Annual Report, ENSI focuses on radiological protection in Swiss nuclear facilities. The average individual dose has changed little compared with previous years. At 0.7 mSv, it is significantly below the limit both for persons exposed to radiation during their work (20 mSv) and the annual average rate of exposure for the population in Switzerland as a whole (5.5 mSv). In terms of collective doses, the extensive maintenance work at the Leibstadt power plant (KKL) resulted in a doubling of rates compared with recent years. However, in the remaining nuclear facilities the rates have not changed significantly. The highest individual dose during the year under review was 13 mSv. Exposure rates in 2012 for all those exposed to radiation during work in facilities subject to ENSI surveillance were below the maximum limit. Greater attention is now being given to work in high and variable radiation fields and in difficult conditions. Swiss nuclear facilities continue to operate a consistent radiological protection approach. Measuring equipment plays an important role in radiological protection. Having conducted a range of inspections and comparative measurements of aerosol-iodine filters and waste water sampling together with measurements in the field of personal dosimetry, ENSI has concluded that the required measuring equipment for radiological protection exists, that this equipment is correctly used and provides reliable data. ENSI maintains a test laboratory that analyses samples from nuclear facilities and their immediate vicinity and also conducts field

  8. Radiologic protection in intensive therapy units; Protecao radiologica em unidades de terapia intensiva

    Energy Technology Data Exchange (ETDEWEB)

    Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S., E-mail: andrea.huhn@ifsc.edu.br, E-mail: juliana@ifsc.edu.br, E-mail: gerusa@ifsc.edu.br, E-mail: laurete@ifsc.edu.br, E-mail: suelen.saraiva@ifsc.edu.br [Instituto Federal de Santa Catarina (IFSC), Florianopolis, SC (Brazil); Derech, Rodrigo D.A., E-mail: dagostiniderech@gmail.com [Policlinica Municipal Sul, Florianopolis, SC (Brazil)

    2013-11-01

    The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)

  9. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Klieber, E

    1986-08-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example.

  10. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    International Nuclear Information System (INIS)

    Rassow, J.; Klieber, E.

    1986-01-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example. (orig.) [de

  11. Radiographic techniques adaptation for any conventional X-ray equipment

    International Nuclear Information System (INIS)

    Pina, Diana R.; Ghilardi Netto, Thomaz; Martinez, Alexandre S.; Duarte, Sergio B.; Trad, Clovis S.; Brochi, Marco Aurelio C.

    2001-01-01

    In order to obtain a better risk-benefice relation in diagnostic radiology it turns out to be essential the control and optimization of the radiographic techniques used to reduce the absorbed doses until its minimum, keeping or adjusting the diagnostic image at any X-ray equipment. The present work deals with the standardization of radiographic techniques of chest, skull and pelvis, which is more suitable for obtaining a safe diagnostic with smaller doses, for a standard patient, at any conventional X-ray equipment. (author)

  12. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  13. Radiological malpractice

    International Nuclear Information System (INIS)

    Bauer, G.

    1987-01-01

    As medico-legal statistics show, compared with other branches of medicine, cases of liability of the radiologist or his assistants are relatively rare. The duty to exercise due care as set out in Paragraph 6 of the Austrian penal code or Paragraph 276 of the German civil code, respectively, provide a basic rule of law also for radiology. Due to the risk inherent in the investigation method, incidents in angiography cannot be totally excluded. Therefore, it is of utmost importance that all steps be taken with regard to staff, equipment and drugs to be able to deal with any complications and incidents that may arise. The courts of law require the employer to produce strongest exonerating evidence to prove that the duty to exercise due care in the selection and supervision of the assistants has been duly fulfilled. For the practical execution of radiological investigations of the digestive tract, also the RTA is responsible; her liability when performing an irrigoscopy is particularly great, as perforation of the intestine is often lethal. The introduction of the rectal tube into the vagina by mistake, with resultant injury or death of the patient, will regularly lead to conviction under penal law. (orig.) [de

  14. AERIAL RADIOLOGICAL SURVEYS

    International Nuclear Information System (INIS)

    Proctor, A.E.

    1997-01-01

    Measuring terrestrial gamma radiation from airborne platforms has proved to be a useful method for characterizing radiation levels over large areas. Over 300 aerial radiological surveys have been carried out over the past 25 years including U.S. Department of Energy (DOE) sites, commercial nuclear power plants, Formerly Utilized Sites Remedial Action Program/Uranium Mine Tailing Remedial Action Program (FUSRAP/UMTRAP) sites, nuclear weapons test sites, contaminated industrial areas, and nuclear accident sites. This paper describes the aerial measurement technology currently in use by the Remote Sensing Laboratory (RSL) for routine environmental surveys and emergency response activities. Equipment, data-collection and -analysis methods, and examples of survey results are described

  15. Training for Radiation Protection in Interventional Radiology

    International Nuclear Information System (INIS)

    Bartal, G.; Sapoval, M.; Ben-Shlomo, A.

    1999-01-01

    Program in radiological equipment has incorporated more powerful x-ray sources into the standard Fluoroscopy and CT systems. Expanding use of interventional procedures carries extensive use of fluoroscopy and CT which are both associated with excessive radiation exposure to the patient and personnel. During cases of Intravenous CT Angiography and direct Intraarterial CT Angiography, one may substitute a substantial number of diagnostic angiography checks. Basic training in interventional radiology hardly includes some of the fundamentals of radiation protection. Radiation Protection in Interventional Radiology must be implemented in daily practice and become an integral part of procedure planning strategy in each and every case. Interventional radiological most master all modern imaging modalities in order to choose the most effective, but least hazardous one. In addition, one must be able to use various imaging techniques (Fluoroscopy, CTA, MM and US) as a stand-alone method, as well as combine two techniques or more. Training programs for fellows: K-based simulation of procedures and radiation protection. Special attention should be taken in the training institutions and a basic training in radiation protection is advised before the trainee is involved in the practical work. Amendment of techniques for balloon and stent deployment with minimal use of fluoroscopy. Attention to the differences between radiation protection in cardiovascular and nonvascular radiology with special measures that must be taken for each one of them (i.e., peripheral angiography vs. stenting, Endo luminal Aortic Stent Graft, or nonvascular procedures such as biliary or endo urological stenting or biliary intervention). A special emphasis should be put on the training techniques of Interventional Radiologists, both beginners and experienced. Patient dose monitoring by maintaining records of fluoroscopic time is better with non-reset timer, but is optional. Lee of automated systems that

  16. The Development of Radiology among Slovenes

    Directory of Open Access Journals (Sweden)

    Zvonka Zupanič Slavec

    2016-10-01

    Full Text Available Few discoveries in the history of science brought such significant progress as did the discovery of X-rays by the German physicist Wilhelm Conrad Röntgen in 1895. The finding did not only bring a revolution to the field of medicine but also to many other technical branches. With technological progress in the 20th century, medical roentgenology swiftly developed. The first significant step forward was the introduction of contrast media followed by others including computerised image data management and digital techniques. Medical diagnostics embraced other imaging methods based on other types of energy such as ultrasound and magnetic resonance imaging. The beginnings of roentgenology in the Slovene Lands go back to the year 1900. Bone fractures were the first to be imaged, followed by thoracic imaging and contrast imaging of the gastrointestinal tract. The use of roentgenology spread significantly after World War I, with the implementation in the following years of X-ray machines in all Slovenian hospitals, some spas and sanatoria. Gradually the need for an independent scientific institution emerged, which led to the establishment of the Roentgenological Institute for Slovenia and Istria in Ljubljana in 1923. At the same time radiology was developing also by other Slovenian hospitals.In the 1950s, Slovenian roentgenology increasingly stayed in touch with contemporary international development, updated its equipment and introduced new methods. The modern concept of centralised radiological management, comparable with that of modern European institutions, was realised in Ljubljana in 1973 after the relocation of the Radiological Institute to the new facilities at the Ljubljana University Medical Centre. The first computer tomography machine was installed in 1980, the first ultrasound machine was acquired in 1981, the first digital subtraction angiography (DSA machine was introduced in 1986 and the first magnetic resonance machine was installed in

  17. Radiation Detection System for Prevention of Radiological and Nuclear Terrorism

    International Nuclear Information System (INIS)

    Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung-Sun; Kim, Jae-Kwang; Kim, Jung-Soo

    2007-01-01

    After the September 11 terrorist attack, the threat of a potential for a radiological or nuclear terrorist attack became more apparent. The threats relating to radiological or nuclear materials include a Radiological Dispersion Device (RDD), an Improved Nuclear Device (IND) or a State Nuclear Device (such as a Soviet manufactured suitcase nuclear weapon). For more effective countermeasures against the disaster, multilayer protection concept - prevention of smuggling of radioactive or nuclear material into our country through seaports or airports, detection and prevention of the threat materials in transit on a road, and prevention of their entry into a target building - is recommended. Due to different surrounding circumstances of where detection system is deployed, different types of radiation detection systems are required. There have been no studies on characteristics of detection equipment required under Korean specific conditions. This paper provides information on technical requirements of radiation detection system to achieve multi-layer countermeasures for the purpose of protecting the public and environment against radiological and nuclear terrorism

  18. O conceito histórico de desenvolvimento econômico

    OpenAIRE

    Pereira, Luiz C. Bresser

    2006-01-01

    Uma Análise do Conceito de Desenvolvimento Econômico. o Crescimento Econômico, ou Desenvolvimento Econômico, é Visto como um Fenômeno Histórico como Resultado da Revolução Capitalista, E, Consequentemente, da Revolução Comercial, da Industrial E, no Meio Delas, da Revolução Nacional. Assim, é Necessário um Conceito Histórico de Crescimento Econômico, e não um Conceito Normativo. Visto sob este Aspecto, o Desenvolvimento Econômico é Intrinsecamente Relacionado ao Surgimento do Estado-Nação M...

  19. Determinantes do desenvolvimento do setor agropecuário nos municípios

    Directory of Open Access Journals (Sweden)

    Caio César de Medeiros Costa

    2013-06-01

    Full Text Available Dada a importância do setor agropecuário para a economia brasileira, é fundamental conhecer os fatores determinantes do desenvolvimento agropecuário em seus municípios. Sob a luz de referencial teórico que aborda questões relacionadas aos fatores determinantes do desenvolvimento agropecuário e do desenvolvimento econômico local, neste estudo fez-se uso das metodologias de análise multivariada conhecidas como análise fatorial e análise de cluster. Utilizou-se o estado de Minas Gerais como recorte analítico. Foram selecionadas 22 variáveis para cada município, representando diferentes dimensões do desenvolvimento, visando verificar quais os fatores determinantes do desenvolvimento agropecuário. Após a análise fatorial, optou-se pela extração de seis fatores com raiz característica maior do que um e que respondem, em conjunto, por 62,25% da variância total dos dados: desenvolvimento econômico, investimento público, qualidade de vida, condições da atividade agropecuária, condições de meio ambiente e consumo, e condições de financiamento. Pela análise de cluster, foram criados cinco grupos, de acordo com o desempenho dos membros nos fatores. Os resultados corroboram os apontamentos literários em quase sua totalidade e, além disso, destaca-se e discute-se a existência de um ciclo positivo gerado pelo incremento dos fatores determinantes do desenvolvimento agropecuário e pelas vantagens competitivas. Neste estudo, aponta-se a importância do investimento público na promoção do desenvolvimento, reforçando o proposto por trabalhos anteriores de que o Estado desempenha papel fundamental para garantir condições que propiciem o desenvolvimento do setor agropecuário. Outra constatação factível é a de que fatores isolados, tais como as boas condições da agricultura e do meio ambiente, não são capazes de propiciar desenvolvimento para o setor nos municípios mineiros.

  20. Comparative analysis of dose levels to patients in radiological procedures guided by fluoroscopy

    International Nuclear Information System (INIS)

    Gomez, Pablo Luis; Fernandez, Manuel; Ramos, Julio A.; Delgado, Jose Miguel; Cons, Nestor

    2013-01-01

    This work presents the comparative data of the dose indicators for patient in radiological processes with respect to the values published in the ICRP document. It is analyzed the need for different strategies to communicate to different specialists mechanisms to optimize the radiation beginning with practice by training of second degree level in radiological protection and then, working with them the basics of equipment management to reduce doses without detriment to the welfare purpose

  1. International conference to explore ways to improve radiological protection of patients

    International Nuclear Information System (INIS)

    2001-01-01

    The first international conference specifically focused on the radiological protection of patients will be held in Torremolinos (Malaga), Spain, next week, from 26 to 30 March 2001. The conference, formally titled, 'International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy', is being organized by the IAEA, hosted by the Government of Spain and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization. Medical applications of ionizing radiation are accepted world-wide as essential tools for keeping or restoring human health. However, they also represent by far the largest man-made source of radiation exposure. The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) estimates that diagnostic medical applications of radiation account for about 95% of the exposure to radiation from man-made sources of radiation and about 12% of total exposure, which includes the exposures received from natural sources. More than 900 participants from 80 countries are expected to attend the conference. They cover a broad spectrum of expertise, including radiologists, nuclear medicine specialists, radiation oncologists, medical physicists, technologists/radiographers, radiological protection officers, equipment manufacturers, experts who develop standards for radiological equipment, hospital administrators and public health officials and representatives of professional societies. In addition, a number of patients who have undergone radiation treatment will represent patients' interests and a patient will chair one of the round table debates. The conclusions of the Conference will be incorporated into the IAEA's programme of work in the field of radiation safety and will be reported to the IAEA General Conference at its next meeting in September 2001

  2. Relevant training issues for introduction of digital radiology: Results of a survey

    International Nuclear Information System (INIS)

    Peer, S.; Faulkner, K.; Torbica, P.; Peer, R.; Busch, H. P.; Vetter, S.; Neofotistou, E.; Back, C.; Bosmans, H.; Vano, E.

    2005-01-01

    Council Directive 97/43/Euratom establishes the need for adequate training of radiology staff. The transition to digital radiology implies changes in various imaging aspects, which are not sufficiently covered by current institutional training programmes. This work aimed to assess how professionals, experienced in digital imaging, acquired their expertise and hence, what form institutional training should take. Within DIMOND III, a survey on training and resources was performed among radiology professionals. A lack of institutional education for digital radiology was found. In the transition to digital radiology, 30-35% train on the job and another 23-28% receive training from digital equipment vendors. A general agreement exists on the need for new quality criteria and strategies for dose management. Issues relevant for conventional/digital transition are only sparsely covered in EC training programmes. Based on these results, a set of training issues was produced, to be included in future European guidelines. (authors)

  3. Dosimetry on the radiological risks prevention in radiotherapy

    International Nuclear Information System (INIS)

    Fornet R, O. M.; Perez G, F.

    2014-08-01

    Dosimetry in its various forms plays a determining role on the radiological risks prevention in radiotherapy. To prove this in this paper is shown an analysis based on the risk matrix method, how the dosimetry can influence in each stages of a radiotherapy service; installation and acceptance, operation, maintenance and calibration. For each one of these stages the role that can play is analyzed as either the initiating event of a radiological accident or limiting barrier of these events of the dosimetric processes used for the individual dosimetry, the area monitoring, fixed or portable, for radiation beam dosimetry and of the patients for a radiotherapy service with cobalt-therapy equipment. The result of the study shows that the application of a prospective approach in the role evaluation of dosimetry in the prevention and mitigation of the consequences of a radiological accident in radiotherapy is crucial and should be subject to permanent evaluation at each development stage of these services. (author)

  4. Uma metodologia para a avaliação de equipes da qualidade através do uso de indicadores /

    OpenAIRE

    Machado, Mônica Cristina Rovaris

    2000-01-01

    Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Este trabalho tem como objetivo central o desenvolvimento de uma metodologia de indicadores da qualidade, visando à melhoria permanente das organizações, através das Equipes da Qualidade. A revisão bibliográfica é apresentada de maneira a refletir os conceitos da qualidade, métodos e modelos através de indicadores, servindo de base para a avaliação organizacional e das Equipes da Qualidade, tendo, como fo...

  5. Quality assurance for radiodiagnostic equipment in Uruguay

    International Nuclear Information System (INIS)

    Cotelo, Elena D.

    2001-01-01

    Since Uruguay did not have an study on X-ray equipment, students of Radiation Protection course (RP) made this field work throughout the country. The objective is to obtain information on the number and kind of X-ray radiodiagnostic equipment. Some of the results are: there are 666 radiodiagnostic equipment. The ratio of population to equipment is 4.515 to 1 in the capital and the mean rate in the rest of the country is 4.383 to one, with a minimum of 1.707 and a maximum of 8.220. The Public Health Ministry (MSP) and the Instituciones de Asistencia Medica Colectiva (a kind of private heath assurance) (IAMC) have less equipment in the capital than in the rest of the country. The 37% of the capital population receives assistance through the IAMC , with a 42.5 % of the equipment. Uruguay except the capital has 18 districts and 17 computed tomography equipment, from which only 3 belong to the MSP. Five districts do not have any. In Montevideo, there are 11.500 females over forty years of age per X-ray mammography equipment, and this relation in the rest of the country is 13.900. There are 21 X-ray Interventional radiology equipment, 16 of them are in the capital. Is from relating the radiodiagnostic equipment, the population and the procedures, that quality assistance indicators emerge. This owns high importance on the way to create a RP National Programme. (author)

  6. A Simulation Learning Approach to Training First Responders for Radiological Emergencies

    International Nuclear Information System (INIS)

    Sanders, Robert Lon; Rhodes, Graham S.

    2007-01-01

    This paper describes the application of simulation learning technology, popularized by the emerging serious games industry, for training first responders to properly act in the event of a radiological emergency. Using state-of-the-art video game production tools and runtime engines as an enabling technology, simulation learning combines interactive virtual worlds based on validated engineering models with engaging storylines and scenarios that invoke the emotional response-and the corresponding human stress level-that first responders would encounter during a real-world emergency. For the application discussed here, in addition to providing engaging instruction about the fundamentals of radiological environments and the proper usage of radiological equipment, simulation learning prepares first responders to perform effectively under high stress and enables them to practice in teams

  7. Protection of staff in interventional radiology

    International Nuclear Information System (INIS)

    Melkamu, M. A.

    2013-04-01

    This project focuses on the interventional radiology. The main objective of this project work was to provide a guidance and advice for occupational exposure and hospital management to optimize radiation protection safety and endorse safety culture. It provides practical information on how to minimize occupational exposure in interventional radiology. In the literature review all considerable parameters to reduce dose to the occupationally exposed are well discussed. These parameters include dose limit, risk estimation, use of dosimeter, personal dose record keeping, analysis of surveillance of occupational dose, investigation levels, and proper use of radiation protection tools and finally about scatter radiation dose rate. In addition the project discusses the ways to reduce occupational exposure in interventional radiology. The methods for dose reduction are minimizing fluoroscopic time, minimizing the number of fluoroscopic image, use of patient dose reduction technologies, use of collimation, planning interventional procedures, positioning in low scattered areas, use of protective shielding, use of appropriate fluoroscopic imaging equipment, giving training for the staff, wearing the dosimeters and know their own dose regularly, and management commitment to quality assurance and quality control system and optimization of radiation protection of safety. (author)

  8. A família e a escola como contextos de desenvolvimento humano

    Directory of Open Access Journals (Sweden)

    Maria Auxiliadora Dessen

    2007-04-01

    Full Text Available Escola e família constituem dois contextos de desenvolvimento fundamentais para a trajetória de vida das pessoas. Neste artigo, são destacadas as contribuições destes contextos para a promoção do desenvolvimento humano, enfatizando suas implicações nos processos evolutivos. Questões sobre configurações, vínculos familiares e a importância da rede social de apoio para o desenvolvimento da família são discutidas. Focalizam-se as funções da escola, considerando sua influência nas pessoas em desenvolvimento. Apontam-se algumas considerações sobre a necessidade de compreender as inter-relações entre escola e família, visando facilitar a aprendizagem e desenvolvimento humano. A integração entre esses dois contextos é destacada como desafio para a prática profissional e pesquisa empírica.

  9. Valores e Desenvolvimento Humano

    NARCIS (Netherlands)

    F. Comim (Flavio); A. Macedo de Jesus (Anderson); R.C.B Oliveira (Raissa); A. Davison (Anna); S. Galeno (Sabrina); A.C.V. Ribeiro (Ana)

    2010-01-01

    markdownabstractA primeira parte desse Relatório de Desenvolvimento Humano do Brasil 2009/2010 começa com a descrição de um amplo processo de consulta aberta à sociedade, denominada Brasil Ponto a Ponto, para a escolha do tema do relatório. A Campanha Brasil Ponto a Ponto teve por objetivo

  10. Absorbed dose to the skin in radiological examinations of upper and lower gastrointestinal tract

    International Nuclear Information System (INIS)

    Zonca, G.; Brusa, A.; Somigliana, A.; Pasqualotto, C.; Sichirollo, A.E.; Bellomi, M.; Cozzi, G.; Severini, A.

    1995-01-01

    Absorbed doses to the skin in radiological examinations of the upper and lower gastronintestinal tract in conventional and digital radiology are evaluated and compared. Absorbed doses were measured with LiF thermoluminescence dosemeters placed on the lower pelvis, umbilicus and forehead of the patient to evaluate the absorbed dose in and outside the primary beam. On 10 patients a reduction in absorbed dose of about 34% for double contrast barium enema and of 66% for upper gastrointestinal tract examinations was revealed with digital radiography equipment. In our working conditions the lower dose requirement for digital radiography is mainly due to image intensifiers and television chains and also, due to our equipment settings, to the dose reduction with digital spot fluorography compared with conventional spot film radiography. (Author)

  11. ICRP Publication 139: Occupational Radiological Protection in Interventional Procedures.

    Science.gov (United States)

    López, P Ortiz; Dauer, L T; Loose, R; Martin, C J; Miller, D L; Vañó, E; Doruff, M; Padovani, R; Massera, G; Yoder, C

    2018-03-01

    In recent publications, such as Publications 117 and 120, the Commission provided practical advice for physicians and other healthcare personnel on measures to protect their patients and themselves during interventional procedures. These measures can only be effective if they are encompassed by a framework of radiological protection elements, and by the availability of professionals with responsibilities in radiological protection. This framework includes a radiological protection programme with a strategy for exposure monitoring, protective garments, education and training, and quality assurance of the programme implementation. Professionals with responsibilities in occupational radiological protection for interventional procedures include: medical physicists; radiological protection specialists; personnel working in dosimetry services; clinical applications support personnel from the suppliers and maintenance companies; staff engaged in training, standardisation of equipment, and procedures; staff responsible for occupational health; hospital administrators responsible for providing financial support; and professional bodies and regulators. This publication addresses these elements and these audiences, and provides advice on specific issues, such as assessment of effective dose from dosimeter readings when an apron is worn, estimation of exposure of the lens of the eye (with and without protective eyewear), extremity monitoring, selection and testing of protective garments, and auditing the interventional procedures when occupational doses are unusually high or low (the latter meaning that the dosimeter may not have been worn).

  12. Preparando um ambiente de desenvolvimento para a plataforma android

    Directory of Open Access Journals (Sweden)

    Felipe Pires de Oliveira

    2015-11-01

    Full Text Available Este artigo descreve as etapas para a criação de um ambiente de desenvolvimento para a plataforma Android. O artigo foi dividido em quatro partes: Primeiro uma introdução sobre o assunto. Na segunda seção são mostrados os passos necessários para a configuração do ambiente de desenvolvimento. Na terceira seção, é demonstrado como criar uma aplicação para dispositivo Android que calculo Índice de Massa Corporal (IMC. A quarta seção apresenta as considerações finais. A solução abordada tem como base a IDE Eclipse e o SDK do Android, bem como o Kit de Desenvolvimento Java da Oracle (JDK.

  13. Preparando um ambiente de desenvolvimento para a plataforma android

    Directory of Open Access Journals (Sweden)

    Felipe Pires de Oliveira

    2015-12-01

    Full Text Available Este artigo descreve as etapas para a criação de um ambiente de desenvolvimento para a plataforma Android. O artigo foi dividido em quatro partes: Primeiro uma introdução sobre o assunto. Na segunda seção são mostrados os passos necessários para a configuração do ambiente de desenvolvimento. Na terceira seção, é demonstrado como criar uma aplicação para dispositivo Android que calculo Índice de Massa Corporal (IMC. A quarta seção apresenta as considerações finais. A solução abordada tem como base a IDE Eclipse e o SDK do Android, bem como o Kit de Desenvolvimento Java da Oracle (JDK.

  14. Evaluation of the conditions and practices of radiological protection technicians in radiology, according to Ordinance 453; Avaliacao das condicoes e das praticas de protecao radiologica dos tecnicos em radiologia, segundo a portaria 453

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rogerio Ferreira da

    2013-10-01

    Professionals in radiology suffer whole body exposure to low doses for long periods . The system of radiological protection should keep exposures below recommended thresholds, thus avoiding the stochastic effects that can be triggered with any dose level value, and there is not a threshold for induction of the same. Therefore it is important to use personal dosimeter for monitoring doses and protective equipment. The increase in procedures using ionizing radiation in recent years has been noted with concern, since many companies are not complying with the standards of protection. This is because some procedures may be performed without the need of surgery, which presents a greater risk to the patient. Furthermore, Brazilians are being exposed to radiation without necessity. The reasons range from radiological equipment miscalibrated to poorly trained staff. Thus we evaluate the conditions and practices of radiation protection technicians in radiology according to Ordinance 453 in Goiania, GO, Brazil. Through a descriptive survey with a quantitative approach, we used the technique of gathering information based on a questionnaire. From this survey, we identified the procedures used by radiation protection professionals and concluded that there are failures in the procedures for protecting patients and accompanying and in the training of the professionals. (author)

  15. Mapping of the radiation field of a mammography equipment using molybdenum and rhodium filters

    International Nuclear Information System (INIS)

    Barreira, Jacqueline S.; Campos, Daniela; Vivolo, Vitor

    2014-01-01

    The use of X rays for diagnostic radiology is very common and important to Medicine, including mammographic diagnosis focusing decreasing of the doses applied to the patients and preserving high quality of the diagnostic image. A quality control program of the irradiation systems it is very necessary. The Instruments Calibration Laboratory (LCI) of IPEN perform calibration in dosemeters used in radiation dosimetry (in diagnostic radiology) for many years. The objective of that paper is determining the point of greatest intensity of the beam issued by the mammography equipment. Exposures were made with filters Rhodium and Molybdenum. That mapping is important before applied a routine quality control program of the mammography equipment and the calibration of instruments in the diagnosis. (author)

  16. Amenidades ambientais e desenvolvimento rural

    OpenAIRE

    Dentinho, Tomaz; Rodrigues, Orlando

    2007-01-01

    Este texto sobre amenidades ambientais e desenvolvimento rural trata, fundamentalmente, da incerteza resultante da reacção das pessoas e das instituições face aos recursos naturais que exploram e quanto ao efeito das políticas que são implementadas.

  17. IAEA Perspectives on Radiological Characterisation

    International Nuclear Information System (INIS)

    O'Sullivan, Patrick; Ljubenov, Vladan

    2012-01-01

    quantity and type of radionuclides, their distribution and their physical and chemical states - e.g. see IAEA report no. TRS-389, Radiological Characterization of Shut Down Nuclear Reactors for Decommissioning Purposes. The collection of detailed data on the physical, chemical and radiological conditions in a nuclear facility, including activity calculations, in situ measurements and/or sampling and analysis, facilitates a detailed estimation of risk, cost and waste generation during decommissioning, and supports the selection of the overall dismantling strategy - e.g. partial vs. full decontamination, requirements for shielding and for partial removal of equipment and services - and its detailed planning. It also supports the assessment of different dismantling options and their consequences, including decontamination and dismantling procedures and tools required, and arrangements to ensure the radiological protection of workers, general public and the environment. (authors)

  18. A mobile radiological laboratory for rapid response to off-site radiation emergencies

    Energy Technology Data Exchange (ETDEWEB)

    Katoch, D. S.; Sharma, R. C.; Mehta, D. J.; Raj, V. Venkat [Bhabha Atomic Research Centre, Mumbai (India)

    2002-07-01

    A mobile radiological laboratory (MRL) has been designed and developed primarily for providing a rapid response to radiation emergencies arising as a consequence of nuclear and/or radiological accidents. It is equipped specifically to monitor the environment and provide quick assessment of radiological hazards to the population living within a radius of 30 km around a nuclear facility. In this paper, various design features of an Indian MRL together with the details of installed equipment are presented. The MRL has been designed for a continuous outdoor operation of about two weeks. It is built on a 10.70 m long air suspension Bus Chassis and has four sections : Driver's Cabin, Main Counting Laboratory, Whole Body Monitor and Rear section housing general utilities. The electric power is provided by two diesel generators during field operation and by 230 V AC mains supply at headquarters and wherever possible. The equipment installed in the MRL includes : Alpha, beta and gamma counting systems and low and high volume air samplers for the assessment of radioactive contents in the samples of air, water, soil and vegetation; environment dose rate meters and a variety of survey meters for evaluating any potential increase in radiation levels; personal dosimeters to control external radiation exposure; personal protective equipment for avoiding skin and clothing contamination; a chair type of whole body monitor for the assessment of internal radioactive contamination of the human body, in particular, thyroidal uptake of radioiodine; an automatic weather station for recording continuously the meteorological parameters and a satellite based global positioning system to continuously track and display the geographical location of the MRL. The calibrations of the installed equipment are presently in progress. Preliminary results obtained for the methods needed for rapid detection of gamma emitters in the environment and human body, namely, in situ gamma spectrometry and

  19. Use of audio-visual methods in radiology and physics courses

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, P

    1987-03-15

    Today's medicine utilizes sophisticated equipment for radiological, biochemical and microbiological investigation procedures and analyses. Hence it is necessary that physicans have adequate scientific and technical knowledge of the apparatus they are using so that the equipment can be used in the most effective way. Partly this knowledge is obtained from science-orientated courses in the preclinical stage of the study program for medical students. To increase the motivation to study science-courses (medical physics) audio-visual methods are used to describe diagnostic and therapeutic procedures in the clinical routines.

  20. Criando contextos ecológicos de desenvolvimento e direitos humanos para adolescentes

    Directory of Open Access Journals (Sweden)

    Ana Paula Lazzaretti de Souza

    2011-08-01

    Full Text Available Neste estudo descreve-se a aplicação do método de Inserção Ecológica em um programa de intervenção para educação em direitos humanos e protagonismo juvenil para adolescentes em situação de vulnerabilidade social. A criação de um microssistema constituído pelos participantes e pela equipe executora do programa resulta em mudanças positivas de comportamento e respeito às regras, entre outros. Estas transformações surgem em consonância com a proposta da Abordagem Bioecológica do Desenvolvimento Humano, sobre a influência do ambiente. Este estudo reforça a importância da aplicação dos resultados em políticas públicas e sociais.

  1. Role of first responder's training in the management of nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Nagarajan, V.; Sankhla, Rajesh; Verma, R.K.

    2008-01-01

    Consequent to the terrorist attacks on WTC in USA and other similar terrorist attacks worldwide, there has been increasing public concern regarding the use of radioactive materials in a malevolent act. As the radioactive sources are widely used in the industries, terrorists may have access to these facilities and obtain the radioactive material suitable for making Radioactive Dispersal Device (RDD) often called as dirty bomb. Response to nuclear or radiological emergency may involve highly specialized agencies or technical experts. Hence well-coordinated arrangements must be integrated with those required for any other conventional emergencies. During radiological emergencies, emergency service personnel are expected to play a major role in the early response. Though these personnel are well equipped and trained in tackling the normal emergencies it is essential to train them to deal with the radiological emergencies due to inherent characteristics of radioactivity. For the effective management of radiological emergencies, these first responders are required to be trained in such a way that they understand the concept of radiation protection. This objective can be achieved by using a typical training module consisting of interactive class room lectures, practical sessions to use the instruments and handling of radioactive sources, demonstration of radiation protection practices, exhibition of all radiation survey instruments and protective equipment etc., display of various posters and RDD Emergency Exercise. (author)

  2. PATRIMÔNIO CULTURAL ARQUEOLÓGICO: INSTRUMENTO DE DESENVOLVIMENTO TURÍSTICO

    OpenAIRE

    Rossano Bastos

    2012-01-01

    O presente trabalho trata das perspectivas de aproveitamento do Patrimônio Cultural Arqueológico como instrumento de desenvolvimento turístico.PALAVRAS-CHAVE: Arqueologia; Turismo;Desenvolvimento.ABSTRACT: This work considers some improvement perspectives ofthe archaeological cultural heritage as an instrument of tourism development.KEY-WORDS: Archaeology; Tourism; Development. 

  3. Opinion: the basic scientist in radiology

    International Nuclear Information System (INIS)

    Holloway, A.F.; Taylor, K.W.

    1984-01-01

    Diagnostic radiology has experienced many scientific and technical advances in the past decade. New imaging methods have allowed diagnostic procedures that have in some cases produced marked advances in treatment of disease. The complexity of the science and technology requires increased knowledge of equipment and techniques on the part of users. This, together with the necessity of exploration of other new developments in science and technology, requires a closer relationship between radiologists on the one hand and basic scientists on the other. (author)

  4. The actual research of radioprotective education on the educational facilities for radiological technologists

    International Nuclear Information System (INIS)

    Miura, Tadashi; Koga, Sukehiko.

    1997-01-01

    The aim of this study was to grasp the actual conditions of the radioprotective education in the educational facilities for radiological technologists, and to discuss the ideal way of radioprotective education toward the 21st century. For this purpose, we sent out the questionnaire concerning the circumstances of radioprotective education to 38 educational facilities for radiological technologists in Japan, including 6 universities, 15 junior colleges and 15 technical schools. This research was carried out on March, 1997, and the answers were obtained total 34 educational facilities (86.8%) (6 universities, 15 junior colleges and 13 technical schools) in total. Among the educational facilities in Japan, universities were much richer than the other two facilities in every respect on the educational circumstances including number and the quality of teaching staffs, educational institutions and equipment, practical training facilities and equipment, the number of collection of books in the library, etc. In the process of education for radiological technologists, the background to cause problems concerning the radioprotective education was largely dependent on the difference of educational schemes in Japan. From the view point of the elevation of educational standard for radiological technologists, it is better to transfer all educational processes to the universities, and give high and full level of radioprotective education in universities. And in the field of the medical radiology, the radioprotection and the management system should also be strengthened. For this purpose, it is also required to revise the related laws drastically, to strengthen lessons related to the radioprotection and to plan the richness in contents of the radioprotective education. (K.H.)

  5. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.

    1996-09-01

    A preliminary radiological dose assessment of equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials (NORM) in production waste streams. The assessment estimated maximum individual dose equivalents for workers and the general public. Sensitivity analyses of certain input parameters also were conducted. On the basis of this assessment, it is concluded that (1) regulations requiring workers to wear respiratory protection during equipment cleaning operations are likely to result in lower worker doses, (2) underground injection and downhole encapsulation of NORM wastes present a negligible risk to the general public, and (3) potential doses to workers and the general public related to smelting NORM-contaminated equipment can be controlled by limiting the contamination level of the initial feed. It is recommended that (1) NORM wastes be further characterized to improve studies of potential radiological doses; (2) states be encouraged to permit subsurface disposal of NORM more readily, provided further assessments support this study; results; (3) further assessment of landspreading NORM wastes be conducted; and (4) the political, economic, sociological, and nonradiological issues related to smelting NORM-contaminated equipment be studied to fully examine the feasibility of this disposal option

  6. Development of a calibration methodology and tests of kerma area product meters; Desenvolvimento de uma metodologia de calibracao e testes de medidores de produto Kerma-Area

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida

    2013-07-01

    The quantity kerma area product (PKA) is important to establish reference levels in diagnostic radiology exams. This quantity can be obtained using a PKA meter. The use of such meters is essential to evaluate the radiation dose in radiological procedures and is a good indicator to make sure that the dose limit to the patient's skin doesn't exceed. Sometimes, these meters come fixed to X radiation equipment, which makes its calibration difficult. In this work, it was developed a methodology for calibration of PKA meters. The instrument used for this purpose was the Patient Dose Calibrator (PDC). It was developed to be used as a reference to check the calibration of PKA and air kerma meters that are used for dosimetry in patients and to verify the consistency and behavior of systems of automatic exposure control. Because it is a new equipment, which, in Brazil, is not yet used as reference equipment for calibration, it was also performed the quality control of this equipment with characterization tests, the calibration and an evaluation of the energy dependence. After the tests, it was proved that the PDC can be used as a reference instrument and that the calibration must be performed in situ, so that the characteristics of each X-ray equipment, where the PKA meters are used, are considered. The calibration was then performed with portable PKA meters and in an interventional radiology equipment that has a PKA meter fixed. The results were good and it was proved the need for calibration of these meters and the importance of in situ calibration with a reference meter. (author)

  7. On-site equipment and materials against CBRNE terrorism

    International Nuclear Information System (INIS)

    Yamamoto, Soichiro; Tokita, Kenichi

    2016-01-01

    There is no almighty field service equipment that can handle by itself all CBRNE (Chemical, Biological, Radiological, Nuclear, Explosive) terrorism. Since there is merit and demerit for each of equipment, operation methods and linkage of material/equipment based on detection principle are indispensable. This paper explained the principle and operation method of detection equipment, operation using multiple material/equipment, and system construction to facilitate cooperation with related ministries and agencies. There are six examples as typical material/equipment and detection principle for handling CBRNE as shown below: (1) ion mobility spectrometer, (2) infrared spectroscopy, (3) Raman scattering spectroscopy, (4) gas chromatographic mass spectrometry, (5) fluorescent reactive dye classification method, and (6) antigen antibody reaction method. This paper shows a flowchart that can measure within the duration of a respirator while wearing Level A protective clothing (about 15 to 20 min) by the combination of detector/analyzer based on these methods. The authors developed an information system that allows prompt information exchange between the on-site administrative agencies, research institutes, and other related organizations via network, in the case when substances etc. could not be specified in the above flowchart. (A.O.)

  8. Radiological incidents in industrial gamma radiography in the Philippines, 1979-1993

    International Nuclear Information System (INIS)

    Borras, A.M.

    1994-01-01

    Among the many practices of radiation sources, the practice of industrial gamma radiography in the country has the most number of reported radiological incidents. During the past fourteen (14) years, from 1979-1993, twenty (20) incidents that have occurred were reported to the Institute. This paper presents the nature and extent of the 20 reported incidents as well as the results of the analysis of why these incidents happened. The results of the analysis showed that the causes of these incidents are mainly human error and equipment failure. Hence, the factors that can minimize or prevent the chance of occurrence and/or recurrence of incidents and in minimizing the hazard in case of radiological incidents are: a) proper training and re-training of personnel; b) proper and regular inspection and maintenance of equipment; c) adequate radiation survey; and d) proper storage and inventory of the radiography sealed sources. (author). 3 refs.; 5 figs.; 1 tab

  9. SU-E-E-06: Teaching Medical Physics in a Radiology Museum

    Energy Technology Data Exchange (ETDEWEB)

    Bednarek, D; Rudin, S [University at Buffalo, Buffalo, NY (United States)

    2014-06-01

    Purpose: To enhance the learning process in the teaching of medical physics by providing a venue to experience the historical equipment and devices of radiology. Methods: We have created a museum by assembling a large collection of equipment and artifacts related to radiology and medical physics. As part of a learning-in-context educational approach, classes for a survey course in medical physics are held in the museum so that students are able to visually and tangibly experience the implements of radiology, while related topics are discussed. The students learn how x-ray equipment and techniques evolved throughout the years and they learn to appreciate the differences and similarities between current x-ray technology and that of the early days. The collection contains items dating from the era of the discovery of x-rays up to recent times and includes gas x-ray tubes, hand-held fluoroscopes, generators, spark-gap kV meters, stereoscopes, glass-plate radiographs, a photofluorographic unit, wood-interspaced grid, flat-panel detector, linear-accelerator klystron, and brachytherapy radium applicators, as well as an extensive library containing some of the seminal literature of the field so that students can delve deeper into the technology. In addition to the classes, guided tours are provided for radiologic-technology, bioengineering, physics and medical students, as well as group and individual tours for the general public. Results: Student course assessments have consistently included positive expressions of their experience in the museum. Numerous students have volunteered to assist with display preparation and have learned by researching the content. Many individuals have been attracted on a walk-in basis and have expressed a deep curiosity in the technology, with positive feedback. Conclusion: The museum and its artifacts have been invaluable in stimulating interest in the history and technology of medical physics. Students and visitors alike obtain a deeper

  10. SU-E-E-06: Teaching Medical Physics in a Radiology Museum

    International Nuclear Information System (INIS)

    Bednarek, D; Rudin, S

    2014-01-01

    Purpose: To enhance the learning process in the teaching of medical physics by providing a venue to experience the historical equipment and devices of radiology. Methods: We have created a museum by assembling a large collection of equipment and artifacts related to radiology and medical physics. As part of a learning-in-context educational approach, classes for a survey course in medical physics are held in the museum so that students are able to visually and tangibly experience the implements of radiology, while related topics are discussed. The students learn how x-ray equipment and techniques evolved throughout the years and they learn to appreciate the differences and similarities between current x-ray technology and that of the early days. The collection contains items dating from the era of the discovery of x-rays up to recent times and includes gas x-ray tubes, hand-held fluoroscopes, generators, spark-gap kV meters, stereoscopes, glass-plate radiographs, a photofluorographic unit, wood-interspaced grid, flat-panel detector, linear-accelerator klystron, and brachytherapy radium applicators, as well as an extensive library containing some of the seminal literature of the field so that students can delve deeper into the technology. In addition to the classes, guided tours are provided for radiologic-technology, bioengineering, physics and medical students, as well as group and individual tours for the general public. Results: Student course assessments have consistently included positive expressions of their experience in the museum. Numerous students have volunteered to assist with display preparation and have learned by researching the content. Many individuals have been attracted on a walk-in basis and have expressed a deep curiosity in the technology, with positive feedback. Conclusion: The museum and its artifacts have been invaluable in stimulating interest in the history and technology of medical physics. Students and visitors alike obtain a deeper

  11. Bacteriological research for the contamination of equipment in chest radiography

    International Nuclear Information System (INIS)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol

    2015-01-01

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections

  12. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  13. Os eventos programados, como alternativo do desenvolvimento do turismo

    Directory of Open Access Journals (Sweden)

    Andrés Pinassi

    2014-10-01

    Full Text Available Turismo e lazer são vistos como uma alternativa para o desenvolvimento econômico, social e cultural de uma comunidade. Ambas práticas de lazer são consolidadas como processos sócio-espaciais que podem trazer muitos impactos benéficos para os moradores de uma determinada localidade. Assim, a dinâmica de eventos programados em aldeias visa proporcionar uma alternativa oportunidades de desenvolvimento local para comunidades carentes. Nesse contexto, a pesquisa desenvolvida, em seguida, analisa o desenvolvimento de um festival especial, realizada na Provincia de Buenos Aires (Argentina. Este festival, iniciado a partir da esfera pública municipal, mostrou benefícios económicos significativos e definir um entretenimento alternativa valiosa para a população local e da área de influência.

  14. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  15. Course of radiological protection and safety in the medical diagnostic with X-rays

    International Nuclear Information System (INIS)

    Dominguez A, C.E.

    1997-01-01

    The obtention of images of human body to the medical diagnostic is one of the more old and generalized applications for X-ray. Therefore the design and performance of equipment and installations as well as the operation procedures must be oriented toward safety with the purpose to guarantee this radiological practice will bring a net positive benefit to the society. Given that in Mexico only exists the standardization related to source and equipment generators of ionizing radiation in the industrial area and medical therapy, but not so to the medical diagnostic area it is the purpose of this work to present those standards related with this application branch. Also it is presented the preparation of a manual for the course named Formation of teachers in radiological protection and safety in the X-ray medical diagnostic in 1997 which was imparted at ININ. (Author)

  16. L-038: EPR-First Responders: Forces / safety equipment. Action Guides

    International Nuclear Information System (INIS)

    2011-01-01

    This conference is about the actions carry out by the forces and the safety equipment in a radiological emergency. The security area, the victims, the hospitals, the police vehicles area, the safety cordon, the evacuation, the contamination level and the risk of life are important aspects to be considered by the first responders.

  17. A study on four-year college curriculum for the education of radiological technology in Korea

    International Nuclear Information System (INIS)

    Choi, Jong Hak; Lee, Sang Suk; Kim, Young Il; Kwon, Dal Gwan; Kim, Heung Tae; Lim, Han Young

    1995-01-01

    The education of radiologic technology began in the regular institute of higher education in Korea in 1963. Up to now from then, our education to bring up the radiologic technologists has developed greatly in quality and quantity, and now departments of radio-technology are founded in the 16 junior colleges in March, 1995. This study was done to verify the necessity and propriety to reform the education system of radiologic technology which was run as two or three year system of college curriculum for 32 years since 1963, and to search for the method to reform in the future. We got the following results from this research. 1. In the survey, on the desirable education year for radiologic technologists, 63.9 % of professors of department of radio-technology and 63.0 % of radiologic technologists chose the 4 year system, 27.9 % of professors and 34.6 % of radiologic technologists chose the 4 year system added to graduate school. 2. In the survey, on the future development of radiologic equipment and technique, 67.2 % of professors of department of radiologic technology and 86.4 % of radiologic technologists have a view of 'revolutional development'. Also, on the future tasks or roles

  18. Desenvolvimento e Gestão Pública: das ideias às práticas

    Directory of Open Access Journals (Sweden)

    Jackeline Amantino de Andrade

    2010-11-01

    Full Text Available Este artigo tem como objetivo tratar dos modelos de desenvolvimento no contexto brasileiro e introduzir uma discussão sobre políticas de desenvolvimento e sua gestão. Para tanto, faz-se necessário resgatar a discussão sobre desenvolvimento tanto em suas bases desenvolvimentistas como a atual proposição de desenvolvimento endógeno. Entende-se que o desenvolvimento depende de uma capacidade organizacional na articulação de vários fatores, tangíveis e intangíveis, quantitativos e qualitativos e envolve várias dimensões: econômica, social, cultural, ambiental e físico-territorial, político-institucional e científico-tecnológica e é construído através de estratégias processuais potencializadas por coletivos. A primeira parte apresenta uma discussão conceitual sobre o desenvolvimento e os processos de organizacionais e de gestão neles implicados. A segunda parte apresenta um estudo empírico de caráter exploratório de modo a ampliar a discussão sobre modelos de desenvolvimento a partir da relação entre teoria e prática. Finalmente, são tecidas algumas considerações sobre o por vir, principalmente, quando se considera que nesses tempos de globalização e de acirramento das desigualdades urge encontrar alternativas justas e solidárias para as sociedades.

  19. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    International Nuclear Information System (INIS)

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs

  20. Evaluation of the conditions of operation of X-ray equipment as regards the coincidence between light field, radiation field and the central ray alignment in radiology services of the Recife, Brazil; Avaliacao das condicoes de funcionamento dos equipamentos de raio X medico no que diz respeito a coincidencia entre campo luminoso e o campo de radiacao e o alinhamento do raio central em servicos de radiologia de Recife

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Claudia F.M.; Silva, Iran J.O.; Lopes Filho, Ferdinand J.; Morais, Carolinne S.; Junior, Claudio L.R., E-mail: claudiamoura.042@gmail.com, E-mail: iranisilva@ig.com.br, E-mail: ferdinand.lopes@oi.com.br, E-mail: carol.smorais@hotmail.com, E-mail: claudio.rd.ifpe@gmail.com [Instituto Federal de Educacao Ciencia e Tecnologia de Pemambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    This paper aims at considering the need for constant evaluation of diagnostic radiology equipment and the fact that this issue be part of the radiology technologist's tasks, develop skills in radiology technologist through applying quality control tests, as regards the assessment of coincidence between the light field and the radiation field and the alignment of the radiation beam of medical X-ray equipment in radiology services in the city of Recife. For the tests, the procedures by national protocols of Quality Control Tests were adopted - QCT and the Medical Radiodiagnosis Manual. The instruments used to check the alignment of the central ray was an acrylic cylinder with steel balls of 0.8 mm diameter located in the upper and lower base separated by a distance of 15 cm, a chassis loaded with film, tape and level bubble. The results show that the tested devices are in good condition for diagnostic radiology, with regard to both the radiation field to be exposed as well as the image quality for a more accurate diagnosis, which guarantees the individual radiological protection.

  1. Second Professional Specialization in Radiological Protection in Peru

    International Nuclear Information System (INIS)

    Medina-Gironzini, E.

    2004-01-01

    Considering that professionals with studies, training and experience in Radiological Protection as a Second Professional Specialization must be recognized, the Peruvian Institute of Nuclear Energy (IPEN), which is the institution responsible for the promotion and control of ionizing radiations in the country, has sign a specific agreement with the Universidad Nacional Mayor de San Marcos, in order to develop these courses. They are based on the content of the Post Graduate Course on Radiological Protection and Nuclear Safety of the Universidad de Buenos Aires, in Argentina, where more than 360 people from 27 different countries have been trained in the last 20 years. People who have a professional degree in Sciences or Engineering, and who fulfill the requirements demanded by the University, study this Second Professional Specialization in Radiological Protection. The studies last 2 years and the courses cover the following subjects: Nuclear Physics, Basic Mathematics, Basic Biology, Radiation Sources, Interaction between Radiation and Matter, Radiation Detection and Measurement, Biological effects of ionizing radiations, Radiological protection in the use of radiations in industry and medicine, Regulatory aspects, and nuclear safety - radiological protection interface. IPEN has taken the responsibility to carry out these studies due to its experience in the organization, together with different Universities, of six Masters in Nuclear Energy, four Masters in Medical Physics, one Master in Nuclear Physics, one Master in Nuclear Chemistry, and two Specialization in Nuclear Medicine. For this purpose, IPEN has the Superior Center of Nuclear Studies (CSEN), which has trained more than 2200 people in radiological protection in more than 30 years. CSEN is the first center in the country to train people in the area of nuclear energy and radiological protection. It has the best staff of professors with a both a great education and professional experience, as well as

  2. Second Professional Specialization in Radiological Protection in Peru

    Energy Technology Data Exchange (ETDEWEB)

    Medina-Gironzini, E.

    2004-07-01

    Considering that professionals with studies, training and experience in Radiological Protection as a Second Professional Specialization must be recognized, the Peruvian Institute of Nuclear Energy (IPEN), which is the institution responsible for the promotion and control of ionizing radiations in the country, has sign a specific agreement with the Universidad Nacional Mayor de San Marcos, in order to develop these courses. They are based on the content of the Post Graduate Course on Radiological Protection and Nuclear Safety of the Universidad de Buenos Aires, in Argentina, where more than 360 people from 27 different countries have been trained in the last 20 years. People who have a professional degree in Sciences or Engineering, and who fulfill the requirements demanded by the University, study this Second Professional Specialization in Radiological Protection. The studies last 2 years and the courses cover the following subjects: Nuclear Physics, Basic Mathematics, Basic Biology, Radiation Sources, Interaction between Radiation and Matter, Radiation Detection and Measurement, Biological effects of ionizing radiations, Radiological protection in the use of radiations in industry and medicine, Regulatory aspects, and nuclear safety - radiological protection interface. IPEN has taken the responsibility to carry out these studies due to its experience in the organization, together with different Universities, of six Masters in Nuclear Energy, four Masters in Medical Physics, one Master in Nuclear Physics, one Master in Nuclear Chemistry, and two Specialization in Nuclear Medicine. For this purpose, IPEN has the Superior Center of Nuclear Studies (CSEN), which has trained more than 2200 people in radiological protection in more than 30 years. CSEN is the first center in the country to train people in the area of nuclear energy and radiological protection. It has the best staff of professors with a both a great education and professional experience, as well as

  3. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  4. Desenvolvimento de um monitor de apneia pediátrico

    OpenAIRE

    Caldeira, Gonçalo José Martins

    2009-01-01

    O trabalho apresentado tem por base o desenvolvimento de um monitor de apneia do sono pediátrico. Aborda questões ao nível da fisiologia respiratória e da mecânica pulmonar de um indivíduo. Apresenta uma proposta de desenvolvimento de um monitor de aquisição e identificação de sinais respiratórios, a fim de efectuar a detecção da apneia do sono.

  5. Desenvolvimento sustentável: um discurso sobre a relação entre desenvolvimento e natureza Sustainable development: a discourse about the relation between development and nature

    Directory of Open Access Journals (Sweden)

    Hugo Juliano Duarte Matias

    2008-04-01

    Full Text Available Trata-se do estudo de definições de desenvolvimento sustentável, elemento fundamental de repertórios interpretativos para a relação entre desenvolvimento e natureza. As definições respondiam a um questionário aplicado a 355 estudantes de vários cursos de uma universidade federal. Realizou-se uma análise de conteúdo que buscou a concepção de natureza e sua relação com desenvolvimento nessas definições. Foram encontradas três matrizes discursivas: (a "economicista" - a necessidade de desenvolvimento subordina a necessidade de preservação da natureza, cujo sentido é "recursos naturais"; (b discurso "bem intencionado" - a necessidade de desenvolvimento subordina a de preservação da natureza, cujo sentido é "fragilidade"; (c "esvaziado" - desenvolvimento e natureza são disjuntos. Conclui-se sobre a importância do estudo da atribuição de significado à natureza para explicar como as pessoas pensam a relação entre desenvolvimento e natureza, e sobre como essas matrizes discursivas podem justificar práticas sociais.This study presents the analysis of definitions of sustainable development, as a basic element of interpretative repertoires for the relation between development and nature. Three hundred and fifty five students of several courses of a federal university answered a questionnaire, providing the definitions, thereafter submitted to content analysis to examine the concept of nature and its relation with development. Three discursive matrixes were found: (a the "economic bias" one - the necessity of development subordinates the need of nature preservation nature is a "natural resources"; (b the "good intentions" discourse - the necessity of development subordinates the necessity of preservation - nature is "fragility"; (c the "empty" - one development and nature are separate. It is concluded that the attribution of meaning to nature is important to explain how people think about the relation between development and

  6. Inglês como língua franca: desenvolvimentos recentes

    Directory of Open Access Journals (Sweden)

    Telma Gimenez

    Full Text Available Em face da atual posição do inglês como uma língua franca global, este artigo tem como principal objetivo discutir os desenvolvimentos recentes dessa área, tomando como base os trabalhos apresentados durante a 7th International Conference on English as a Lingua Franca, realizada em Atenas, Grécia, em setembro de 2014. As reflexões, aprofundadas nos tópicos i Teorizações sobre ILF; ii ILF e formação de professores; iii Desenvolvimentos futuros, trazem um olhar analítico sobre os temas discutidos no evento. Espera-se que as informações e reflexões aqui contempladas possam contribuir para o desenvolvimento de uma "curiosidade acadêmica" a respeito do paradigma ILF (inglês como língua franca e para o engajamento com suas questões e implicações.

  7. Mobile Radiological Laboratories Intercomparison Measurements - Chernobyl

    International Nuclear Information System (INIS)

    Martincic, R.; Glavic-Cindro, D.; Korun, M.; Pucelj, B.; Vodenik, B.

    2001-01-01

    Full text: In last decade different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the preparedness of emergency monitoring teams. The 12th Regular Workshop on Mobile Radiological Laboratories was held in Exclusion Zone of the Chernobyl NPP, Ukraine from September 13 to September 18, 1999 under the acronym MORAL-12. The European Centre of Technological Safety (TESEC), Kiev, Ukraine and J. Stefan Institute, Ljubljana, Slovenia organised Intercomparison Measurements 99 jointly under the auspices of the International Atomic Energy Agency (IAEA). Nineteen teams from 9 countries and IAEA participated in the Workshop. Six field and personal and equipment contamination control exercises were prepared and conducted at two measuring sites with very different ambient dose rate levels. The Workshop pointed out that such exercises are very valuable for rapid, efficient and harmonised emergency response in case of nuclear or radiological emergency. The teams had an opportunity to test their ability to perform field measurements in the contaminated environment, and to report results on the spot, as well as to test their emergency preparedness and persistence. They gained new experiences for fieldwork under stress conditions. An overview and results of these intercomparison measurements are presented and lessons learned are discussed. (author)

  8. CERVEJA ARTESANAL E DESENVOLVIMENTO REGIONAL EM SANTA CATARINA (BRASIL

    Directory of Open Access Journals (Sweden)

    Valdinho Pellin

    2016-12-01

    Full Text Available Discussões relacionadas ao fortalecimento do desenvolvimento regional tem estimulado um debate em relação a contribuições que Indicações Geográficas (IGs podem oferecer ao desenvolvimento. IGs se constituem em elemento de identificação de produtos ou serviços com seus territórios e podem oferecer contribuições importantes para o desenvolvimento regional, agregando valor aos produtos, facilitando o acesso a novos mercados e valorizando tradições locais. Este artigo procura discutir a importância da cerveja artesanal no contexto do desenvolvimento regional em Santa Catarina. Para tanto explora como objetivos específicos: (i caracterizar as discussões que estão ocorrendo em torno do reconhecimento da IG para chope e cerveja artesanal na região de Blumenau (SC; (ii identificar contribuições e desafios para o Desenvolvimento Regional de um possível reconhecimento da IG; e (iii caracterizar limites e potencialidades sinalizados pela iniciativa em curso. Metodologicamente trata-se de pesquisa analítica e descritiva baseada em estudo de caso de natureza exploratória. Como instrumento de coleta de dados se realizou entrevistas semiestruturadas com gestores de micro cervejarias artesanais da região e atores públicos e privados envolvidos diretamente nas discussões. Além destas fontes primárias o estudo fundamentou-se em fontes consubstanciadas pelos documentos produzidos nas reuniões de trabalho realizadas até o presente. Os principais resultados de análise destacam que um possível reconhecimento da IG poderia contribuir para o fortalecimento do setor, aumentando a competitividade, além de fortalecer a atividade turística na região. Entretanto para isso, alguns conflitos, surgidos no âmbito das discussões, precisam ser assumidos, superados ou mitigados

  9. Desenvolvimento e avaliação de instrumentos de triagem nutricional

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Aquino

    2012-08-01

    Full Text Available Esse estudo tem por objetivo descrever o desenvolvimento e a avaliação de instrumentos de triagem nutricional para identificação de risco de desnutrição em pacientes hospitalizados. A partir da identificação de variáveis preditivas, o paciente deve ser encaminhado à equipe multidisciplinar de terapia nutricional para intervenção. Foram estudados 300 pacientes de um hospital de São Paulo-SP, aplicada uma avaliação nutricional com levantamento de variáveis de risco e conduzida uma regressão logística múltipla para a seleção dos fatores preditivos. As variáveis associadas à desnutrição foram: perda de peso involuntária, ossatura aparente, redução de apetite, diarreia, ingestão energética inadequada e gênero masculino. Um instrumento de triagem nutricional foi desenvolvido e apresentou adequada concordância com instrumentos validados.

  10. Uroradiology in 117 year history of radiology

    International Nuclear Information System (INIS)

    Naumov, N.

    2013-01-01

    Full text: Introduction: ‘In order to understand the present and see the future, you must know the past'. This motto, used by Professor Jean-Franois Moreau in his presentation ‘A Century uroradiology in Europe 1896 -1996’, is the occasion, with his consent and participation to complement the presentation not only with what comes as a change in our profession in recent years, but also to celebrate milestones in the development of uroradiology in Bulgaria. One of the major health problems in Europe, not only in the late 19th century, but today is renal calculi. For this reason, five months after the described by Wilhelm Conrad Roentgen X- rays attempts to use them in medical practice by urologists namely in seeking opportunities to demonstrate calculi began. What you will learn: This justifies the first phase, covering 1896-1929, has not only uroradiology but of radiology as a whole, in which it is a hobby of the urologists. Summarizing the main points as in the technical development of radiological equipment, but above all the introduction of diagnostic methods, some of which have not lost their relevance and today, this period naturally ends with one of the most epochal discoveries in medicine and first diagnostic method combining morphological with functional diagnostics - excretory urography . The second step, covering the period of 1929-1960, is characterized by increasing further improvement of the equipment, but also of the applied diagnostic methods, as the urologist is still leading in applying these methods, but now with the technical assistance of the radiologist. After World War II, this approach began to change, besides the appearance of chapters on uroradiology in major guidelines in diagnostic radiology, new methods have been developed, and including vascular contrast diagnostic are made and implemented by radiologists. The third stage, cover the period 1960-1980, entitled ‘Fathers of uroradiology’ account entry of CT low-osmolar nonionic

  11. Methods of determining the effective dose in dental radiology

    International Nuclear Information System (INIS)

    Thilander-Klang, A.; Helmrot, E.

    2010-01-01

    A wide variety of X-ray equipment is used today in dental radiology, including intra-oral, ortho-pan-tomographic, cephalo-metric, cone-beam computed tomography (CBCT) and computed tomography (CT). This raises the question of how the radiation risks resulting from different kinds of examinations should be compared. The risk to the patient is usually expressed in terms of effective dose. However, it is difficult to determine its reliability, and it is difficult to make comparisons, especially when different modalities are used. The classification of the new CBCT units is also problematic as they are sometimes classified as CT units. This will lead to problems in choosing the best dosimetric method, especially when the examination geometry resembles more on an ordinary ortho-pan-tomographic examination, as the axis of rotation is not at the centre of the patient, and small radiation field sizes are used. The purpose of this study was to present different methods for the estimation of the effective dose from the equipment currently used in dental radiology, and to discuss their limitations. The methods are compared based on commonly used measurable and computable dose quantities, and their reliability in the estimation of the effective dose. (authors)

  12. An overview of dental radiology in cities of Brazil

    International Nuclear Information System (INIS)

    Menezes, F.L.; Paschoal, C.M.M.; Ferreira, F.C.L.; Belinato, W.

    2015-01-01

    In Brazil, the National Ordinance No. 453/1998 of the Ministry of Health regulates the operation of medical and odontological diagnostic radiology services. However, the inspection of periapical dental X-ray equipment is not carried out by some Sanitary Surveillances. This study intended to determine the suitability to the ordinance of the dental offices of Sobral-CE, Northeast of Brazil, and to compare the results with literature data for other cities of Brazil, giving a view of dental radiology of this country. It was performed tests of radiation field and image quality, and it was applied questionnaires to the professionals of Sobral-CE. For the image quality test, it was used a dental phantom and the processing of the films was performed in the clinics and at the laboratory (standard). The questionnaire assessed physical parameters that interfere on the radiation protection and on the quality of images. The results show that the ordinance is not being properly followed and that it is necessary to inspect the periapical X-ray equipments. Moreover, in general, it is observed that dental professionals should have better training on ionizing radiation and on radiation protection. (authors)

  13. Quality index in medical radiology; Indice de qualidade em radiologia medica

    Energy Technology Data Exchange (ETDEWEB)

    Travassos, Paulo Cesar B.; Magalhaes, Luis Alexandre Goncalves; Drexler, Gunter G.; Almeida, Carlos E. de, E-mail: luisalexandregm@hotmail.com [Universidade do Estado do Rio de Janeiro (IBRAG/UERJ), RJ (Brazil). Instituto de Biologia. Laboratorio de Ciencias Radiologicas; Navarro, Marcus V. [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil)

    2012-08-15

    In the literature there are articles with methods for the calculation of potential risk in medical radiodiagnostics institutions: Evaluation Model for Potential Risk (MARP). These articles present results based on documental evaluation of the institutions, but they suggest that quantitative data from the equipment's quality assurance can be included. This article proposes an evaluation of medical radiology institutions with a variation of the Potential Risk model, which considers, besides the administrative factors, quantitative results from equipment's quality assurance: the quality index. Results of the application of this proposition in 42 institutions are presented, with 52 evaluated conventional X-Ray equipment, located in the state of Rio de Janeiro, Brazil. (author)

  14. Radiological characterisation and decommissioning in Denmark

    International Nuclear Information System (INIS)

    Nellemenn, Thomas

    2012-01-01

    Danish Decommissioning (DD) is currently decommissioning the last Danish research reactor (DR3) and the Hot Cell facility. The DR3 project will soon finish dismantling of the external parts of the reactor (January 2012). The approval for dismantling of neutron activated and tritium contaminated heavy water pumps and tubing was granted in December 2011. DD will begin the work on the inner parts as the tendering process for equipment will start in 2012. Hereafter the dismantling of the top of the reactor will begin using the obtained remote controlled equipment. The Hot Cell facility consists of 6 contaminated cells. The first cell have been opened and cleaned. Currently the work progresses by removing parts and hot spots from the other cells with the use of robotic equipment. Challenges, lack of conventional and radiological documentation, dose rates and contamination higher than expected and the confined space in the cells have delayed the project. No final repository exists in Denmark. Therefore no official Waste Acceptance Criteria (WAC) have been formulated. However the Danish authority (SIS) does require a description of the waste in the interim storage facility (Inventory). Furthermore radiological characterisation of key nuclides is needed during decommissioning and dismantling. The information gained from the characterisation helps in the planning phase prior to the dismantling and for inventory calculations for later use. DD performs the radiological characterisation via both non-destructive and destructive analysis on samples. The samples are measured with gamma spectroscopy using mathematical and geometrical analysis. Scaling factors are used for neutron activated waste (DR3) to determine the difficult-to-measure isotopes and pure beta emitters. The primary scaling isotope is Co-60. Waste from the Hot Cell facility is alpha contaminated and scaling procedures for determination of alpha contamination are currently used in the planning process. Scaling of

  15. Tutorial para o Desenvolvimento de Jogos 2D usando a Linguagem Java

    Directory of Open Access Journals (Sweden)

    Soraia Teixeira Barbosa

    2015-07-01

    Full Text Available Atualmente é grande o estudo e desenvolvimento de jogos eletrônicos tanto no meio acadêmico como fora dele. Entretanto o desenvolvimento do mesmo não é uma tarefa trivial. Este artigo mostra o desenvolvimento de um jogo computacional através de uma versão do conhecido jogo de arcade Space Invaders. O artigo proposto tem como objetivo mostrar os passos básicos para a construção de um jogo computacional em duas dimensões utilizando a linguagem de programação Java.

  16. The use of audio-visual methods in radiology and physics courses

    International Nuclear Information System (INIS)

    Holmberg, P.

    1987-01-01

    Today's medicine utilizes sophisticated equipment for radiological, biochemical and microbiological investigation procedures and analyses. Hence it is necessary that physicans have adequate scientific and technical knowledge of the apparatus they are using so that the equipment can be used in the most effective way. Partly this knowledge is obtained from science-orientated courses in the preclinical stage of the study program for medical students. To increase the motivation to study science-courses (medical physics) audio-visual methods are used to describe diagnostic and therapeutic procedures in the clinical routines. (orig.)

  17. Regulatory aspects of the enforcement policy applied to teletherapy equipment obsolescence (1995-2002)

    International Nuclear Information System (INIS)

    Truppa, Walter A.; Rey, Hugo L.; Rojas, Carlos A.

    2004-01-01

    The paper describes the way in which the Nuclear Regulatory Authority (ARN) has implemented an 'enforcement' policy for the services of radiotherapy that operated obsolete cobalt therapy units. Without doubt one of the greater advances has been the simulation and planning of the treatment, indispensable tools in a system of quality in radiotherapy where the equipment acquires a preponderant paper. In Argentina the distribution of equipment was inhomogeneous, and within it coexisted, as primary and unique units, great amount with a technology today already obsolete. The Nuclear Regulatory Authority (ARN) took a strong regulatory attitude directed to change or to retire many of the units, as its characteristics of design and antiquity did not fulfill the criteria of radiological security established in the norms (optimization of the dose, distances source to skin, yield in surface, adequate maintenance, etc.). On this matter a policy was applied to impose within suitable terms, the change of the obsolete equipment for this practice, particularly those distances source to skin minor than 80 cm. As result of the applied coercive measures at this moment, 28 equipment of cobalt therapy in advanced degree of obsolescence were retired by regulatory decision. Part of these equipment were replaced by their owners by more modern equipment whose operation adjusts to the requirements of the radiological security norm, whereas the majority was replaced by linear accelerators. At the moment there are 86 of cobalt therapy units and 52 accelerators operating in our country, against 104 and 32 respectively, that operated in 1995. (author)

  18. Proposed radiological protection rules for patients in radiodiagnostics

    International Nuclear Information System (INIS)

    Yacovenco, A.; Souza, A.C.A.; Ferreira, R.S.

    1998-01-01

    Faced with the increasing exposure of the population to ionizing radiations and the need to respect users' rights, political and scientific efforts have been undertaken in order to improve image quality in radiodiagnostics and reduce risks to patients. In Brazil, in the past 20 years, a low rate of investment in this area and inadequate health policies have lead to diagnostic radiology services of poor quality. For their part, scientific societies, professional associations and the Ministry of Health have issued federal and state norms which require the control of physical parameters of the radiological equipment. Consequently, there is a need to create a National Reference Laboratory to oversee, inspect and evaluate the implementation of such norms. Another topic addressed in this article is the professional profile of the Medical Physics Specialist. (author)

  19. Radiological protection principles concerning the safeguard, use or release of contaminated materials, buildings, areas or dumps from uranium mining. Recommendations of the Commission on Radiological Protection with explanations

    International Nuclear Information System (INIS)

    Mueller-Neumann, M.

    1992-01-01

    The volume presents the full texts of the SSK Recommendations addressing the aspects and problems involved, and which can be separately retrieved from the database: 1) Radiological protection principles concerning the release of scrap from the shut-down of uranium mining plants; 2) Radiological protection principles concerning the release for industrial use of areas contaminated from uranium mining; 3) Radiological protection principles concerning the use for forest and agricultural purposes and as public gardens (parks) and residential areas of areas contaminated from uranium mining; 4) Radiological protection principles concerning the safeguard and use of mine dumps; 5) Radiological protection principles concerning the release for further commercial or industrial use of buildings used for commercial or industrial purposes and the disposal of building debris from uranium mining and milling; 6) Radiological protection principles concerning the release for general use of reusable equipment and installations from uranium mining. The following appendices round up the material: 1) Radiation exposure from mining in Saxony and Thuringia and its evaluation (Summary of the results of consultations during the 1990 closed meeting); 2) Radiological protection principles for the limitation of the radiation exposure of the public to radon and its daughters; 3) Epidemiological studies on the health state of the inhabitants of the mining region and the miners in Saxony and Thuringia. (orig.) [de

  20. Patient dosimetry in interventional radiology

    International Nuclear Information System (INIS)

    Silva, Mauro Wilson O. da; Canevaro, Lucia V.; Rodrigues, Barbara Beatriz D.

    2009-01-01

    Mapping skin doses in interventional radiology is useful to determine the probability of a possible injury, to detect areas of overlapping field and to obtain a permanent register of the most exposed skin areas. A method for the evaluation of patient doses in interventional radiology procedures is the slow film, Kodak EDR2 (Extended Dose Range). Kodak EDR 2 film was calibrated in the range of 50 kVp to 120 kVp beam qualities. Its dose-response curve was plotted up to the saturation point of 1000 mGy. Dose responses are a function of facility dependent factors including processing conditions the density sampling, and exposure monitoring equipment. The distribution and the form of all the irradiation fields have been registered in the Kodak EDR 2 films. The Dosimetric analysis was performed in a sample of 37 patients submitted the procedures coronariography and angioplasty. The film has a threshold of saturation around 1 Gy, the applied methodology is efficient to quantify the doses and to identify the distribution of the fields. (author)

  1. Guidelines for planning and design of mobile radiological units

    Energy Technology Data Exchange (ETDEWEB)

    Schelenz, R [Federal Office for Environmental Radioactivity in Food, Total Diet and Infant Food, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    1995-07-01

    A significant number of mobile radiological units are in operation worldwide aiming to provide reliable radiological data. They mainly have been designed and constructed on a national basis according to the particular needs and commitments of the specific laboratory or country. In most cases, these units are intended to be used in emergency situations for in-situ radiological measurements of accidentally released radioactivity, sometimes for monitoring environmental pollution. As the purpose of these units is very diversified in regard to the kind of vehicle and its in-built measuring equipment the varying outfit of these units cannot be adopted in general for other countries aiming to improve their capability for in-situ radiological measurement. In order to achieve harmonization of equipment and comparability of radiological data being obtained from field measurements it is necessary to have general guidelines available for designing mobile radiological units taking into account different sceneries and tasks to be achieved. In the very early stages of an accident most of the information available on the quantity of radioactive material being released, its radionuclide composition and the likely progression of the accident will come from the operator, and will be based on the conditions in the plant. Few environmental monitoring results from off-side can be expected within the first few hours. In this very early phase, decisions on the application of protective measures will therefore, be based largely on plant status and forecasts of changes in that status as well as on meteorological data. As time progresses, results will increasingly become available from the monitoring of radionuclides in the environment (e.g. dose rates and concentration of radionuclides in air and particular materials such as water, food etc). Monitoring results can be used to estimate potential doses to people and the need for further protective measures can thus be determined from a

  2. Guidelines for planning and design of mobile radiological units

    International Nuclear Information System (INIS)

    Schelenz, R.

    1995-01-01

    A significant number of mobile radiological units are in operation worldwide aiming to provide reliable radiological data. They mainly have been designed and constructed on a national basis according to the particular needs and commitments of the specific laboratory or country. In most cases, these units are intended to be used in emergency situations for in-situ radiological measurements of accidentally released radioactivity, sometimes for monitoring environmental pollution. As the purpose of these units is very diversified in regard to the kind of vehicle and its in-built measuring equipment the varying outfit of these units cannot be adopted in general for other countries aiming to improve their capability for in-situ radiological measurement. In order to achieve harmonization of equipment and comparability of radiological data being obtained from field measurements it is necessary to have general guidelines available for designing mobile radiological units taking into account different sceneries and tasks to be achieved. In the very early stages of an accident most of the information available on the quantity of radioactive material being released, its radionuclide composition and the likely progression of the accident will come from the operator, and will be based on the conditions in the plant. Few environmental monitoring results from off-side can be expected within the first few hours. In this very early phase, decisions on the application of protective measures will therefore, be based largely on plant status and forecasts of changes in that status as well as on meteorological data. As time progresses, results will increasingly become available from the monitoring of radionuclides in the environment (e.g. dose rates and concentration of radionuclides in air and particular materials such as water, food etc). Monitoring results can be used to estimate potential doses to people and the need for further protective measures can thus be determined from a

  3. CHALLENGES IN SETTING UP QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY FACILITIES IN NIGERIA.

    Science.gov (United States)

    Inyang, S O; Egbe, N O; Ekpo, E

    2015-01-01

    The Nigerian Nuclear Regulatory Authority (NNRA) was established to regulate and control the use of radioactive and radiation emitting sources in Nigeria. Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the authorization of diagnostic radiology facilities in the Country. Some quality control tests (output, exposure linearity and reproducibility) were measured on the x-ray machines in the facilities that took part in the study. Questionnaire was developed to evaluate the frequencies at which QC tests were conducted in the facilities and the challenges in setting up QC. Results show great variation in the values of the QC parameters measured. Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study. The responses on the frequencies at which QC tests should be conducted did not correspond to the recommended standards; indicating that personnel were not familiar with QC implementation and may require further training on QC.

  4. Data Management and Tools for the Access to the Radiological Areas at CERN

    CERN Document Server

    Sanchez-Corral Mena, E; Dorsival, A; Dumont, G; Foraz, K; Hakulinen, T; Havart, F; Kepinski, M P; Mallon Amerigo, S; Martel, P; Ninin, P; Nunes, R; Valentini, F; Vollaire, J

    2014-01-01

    As part of the refurbishment of the PS accelerator complex Personnel Protection System, the Radiation Protection (RP) checkpoints and buffer zones, for the radiological controls of equipment removed from the beam areas, have been incorporated into the design of the new access points.

  5. Radiometer evaluation of X-rays equipment in the region of Aracatuba, Sao Paulo, Brazil;Avaliacao radiometrica de raios-X na regiao de Aracatuba, Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Marco A.R. [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina; Kanezawa, Jorge S. [Centro de Ensino e Tecnologia de Aracatuba (CETEA), SP (Brazil)

    2009-07-01

    This paper presents the basic concepts of radiation protection to guide the health care professionals who use equipment emitting ionizing radiation on the correct handling of the beams of radiation. Radiometric evaluations were conducted in 1665 in X-ray equipment, installed in dental surgeries and clinics, hospitals and radiology services, during the years 1996 to 2003 in the region of Aracatuba. Tests of radiometry are presented as a technical report where the parameters are quantified physical and radiological verifying its compliance with the established by legislation. The distribution of reports by type of unit shows that the vast majority of equipment is of periapical dental x-rays (72%), 25% of equipment is medical equipment for radiology and 3% is dental equipment panoramic model (orthodontic documentation). Among the physical parameters analyzed, the length of the browser was showing more variance compared to the required by law, this fact may also contribute to gaps in the rate of the radiation dose and the size of field in the skin of the patient, the that can easily be resolved simply to replace the piece at the outlet of the head. During the completion of visits to services, it also noted a gap in the training of professionals who operate this equipment emitting radiation, warning of the need for specific training in the area. (author)

  6. Specialized consultant in radiological safety to the Ciudad del Carmen general hospital, PEMEX

    International Nuclear Information System (INIS)

    Angeles C, A.; Hernandez C, J. E.; Rodriguez A, F.; Garcia A, J.

    2003-02-01

    The Ciudad del Carmen general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  7. DANÇA E O DESENVOLVIMENTO MOTOR DE PORTADORES DE NECESSIDADES EDUCATIVAS ESPECIAIS - PNEEs

    Directory of Open Access Journals (Sweden)

    Liliane de Oliveira

    2012-04-01

    Full Text Available O estudo objetivou verificar as modificações nos padrões de desenvolvimento motor de PNEEs mediante prática da dança. Participaram 14 PNEEs do CIEP/Cruz Alta. O instrumento foi a Escala de Desenvolvimento Motor (Rosa Neto, 1996. Utilizou-se a estatística descritiva e teste “t” para análise dos dados. Observou-se diferenças estatisticamente significativas (p<0,05 entre pré e pós-testes nas variáveis idade cronológica, motora geral, motricidade ampla e equilíbrio. Concluiu-se que o programa de dança contribuiu significativamente para o desenvolvimento motor de PNEEs. Palavras chave: dança, motor, desenvolvimento, especial, educação.

  8. Pediatric radiology for medical-technical radiology assistants/radiologists

    International Nuclear Information System (INIS)

    Oppelt, Birgit

    2010-01-01

    The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.

  9. Elaboração e avaliação de um website sobre o desenvolvimento da linguagem infantil: portal dos bebês - desenvolvimento da linguagem

    Directory of Open Access Journals (Sweden)

    Aline Martins

    2015-02-01

    Full Text Available OBJETIVO: criar e desenvolver um website na área de fonoaudiologia com enfoque no desenvolvimento da linguagem de bebês de 0 a 48 meses, além de avaliar a qualidade do conteúdo apresentado e os recursos tecnológicos utilizados. MÉTODOS: na primeira fase do projeto foi realizado um levantamento de dados por meio de revisão de literatura sobre o desenvolvimento e aquisição da linguagem infantil. Em seguida esse conteúdo foi inserido no website e avaliado por 20 pais e/ou cuidadores. RESULTADO: o website Portal dos Bebês - Desenvolvimento da Linguagem foi desenvolvido com linguagem voltada a pais e/ou cuidadores, e seu conteúdo foi dividido em três temas: "Desenvolvimento da Linguagem", "Fala e Linguagem" e "Linguagem e o Ambiente". No que se refere à qualidade do conteúdo e da apresentação, o website foi avaliado como "excelente" por todos os participantes da amostra. Quanto à avaliação sobre o vocabulário utilizado e a forma de apresentação do conteúdo, 70% e 75% respectivamente, consideraram o website como "excelente". Em relação à apresentação visual, 85% dos participantes classificaram como "excelentes", já o tipo de navegação foi classificado como "satisfatório" por 50% dos participantes. Quanto à importância que os pais e/ou cuidadores julgam sobre o site a maioria classificou como "excelente" o auxilio que o mesmo dá no desenvolvimento da linguagem da criança. CONCLUSÃO: o website Portal dos Bebês - Desenvolvimento da Linguagem pode ser acessado pelo endereço online http://portaldosbebes.fob.usp.br, e seu conteúdo e recursos tecnológicos utilizados foram avaliados como satisfatório a excelente pelos pais e/ou cuidadores participantes.

  10. Analyses of superficial and depth doses in intraoral radiology

    Energy Technology Data Exchange (ETDEWEB)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do [Universidade Federal de Sergipe - CCET - Dept. de Fisica, Sao Cristovao, SE (Brazil)

    2006-07-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  11. Analyses of superficial and depth doses in intraoral radiology

    International Nuclear Information System (INIS)

    Silva Santos de Oliveira, C.; Morais, R.P. de; Nascimento Souza, D. do

    2006-01-01

    In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO 4 :Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film packet holder. The evaluation of the depth doses in the intraoral tissue was obtained using different acrylic plate thickness. The air kerma values have been evaluated with the ionization chamber located in the dental cone exit of the x-rays equipments. The integrated areas of the thermoluminescent glow curves showed coherent values when compared to the ones obtained with the ionization chamber and both methods presented a linear dependence with the exposition time. The analyses with films have allowed the evaluation of the beam scattering in the simulator apparatus. The studies had proven that the analysis of superficial dose and in depth used in dental radiology can be carried with thermoluminescent dosimeters. (authors)

  12. 100 years from the invention of X-rays. From the history of the radiology in Slovakia

    International Nuclear Information System (INIS)

    Kutarna, A.

    1996-01-01

    The survey of the development of radiology after the First World War (after disintegration of Austro-Hungarian Monarchy) as well as after the Second World War in Slovakia is given. Attention is dedicated to the development of radiodiagnostic and radiotherapeutic methods in Slovakia, as well as to personal occupation of the heads of radiologic clinics. In the last decade radiologic working-places and the departments are equipped with modern and efficient techniques. While in the year 1962 a number of the radiologists was about 90 doctors, in the year 1995 a number more than 360 doctors was registered from which are 80 doctors of radiotherapy. A number of radiologic assistants is about 1200. In Slovak hospitals are about 370 departments of radiology and more than 300 radiodiagnostic working-places and 12 departments of radiotherapy. 29 refs

  13. Simplified slide production in radiology departments

    International Nuclear Information System (INIS)

    Groves, J.R.; Goethlin, J.H.

    1987-01-01

    A slide-producing system is described, the goal of which is to copy radiographs, typewritten and printed text onto 35 mm film for teaching purposes, records or publication. Automation permits the equipment to be used by persons not familiar with photography. By following simple procedures, high-quality results can be obtained. Advantages of the system are low cost, small space requirements and utilisation of existing facilities such as X-ray dark rooms and processors. Any radiological department requiring quick, low-cost visual materials should consider the convenience of the system described. (orig.)

  14. Radiological incident preparedness for community hospitals: a demonstration project.

    Science.gov (United States)

    Jafari, Mary Ellen

    2010-08-01

    In November 2007, the Wisconsin Division of Public Health Hospital Disaster Preparedness Program State Expert Panel on Radiation Emergencies issued a report titled The Management of Patients in a Radiological Incident. Gundersen Lutheran Health System was selected to conduct a demonstration project to implement the recommendations in that report. A comprehensive radiological incident response plan was developed and implemented in the hospital's Trauma and Emergency Center, including the purchase and installation of radiation detection and identification equipment, staff education and training, a tabletop exercise, and three mock incident test exercises. The project demonstrated that the State Expert Panel report provides a flexible template that can be implemented at community hospitals using existing staff for an approximate cost of $25,000.

  15. A COMPLEXIDADE ECONÔMICA DOS DIREITOS HUMANOS: UMA DIMENSÃO ESCONDIDA DO DESENVOLVIMENTO HUMANO

    Directory of Open Access Journals (Sweden)

    Leilane Serratine Grubba

    2012-10-01

    Full Text Available Este artigo tem por objeto a complexidade econômica dos direitos humanos, mais precisamente, a investigação da relação entre a complexidade econômica e o desenvolvimento humano. Nesse sentido, objetivou demonstrar a intrínseca relação e dependência do desenvolvimento humano à complexidade econômica dos direitos humanos, que influi na positivação dos direitos, assim como na luta pelo acesso aos bens necessários a uma vida digna. Por meio do método dedutivo, o artigo problematizou a relação entre o ser humano e seu contexto econômico-social para o desenvolvimento da vida em dignidade. Diante disso, em primeiro lugar, foi apresentada a noção de complexidade dos direitos humanos, isto é, as suas múltiplas dimensões. No segundo momento, foi analisada a questão econômica do desenvolvimento humano, ou seja, a relação entre o desenvolvimento da vida digna e a dimensão econômica da sociedade, e, finalmente, foi apresentada a complexidade econômica dos direitos humanos. O desenvolvimento humano não está apenas vinculado à dimensão econômica, mas compreende todas as dimensões (complexidade que perfazem uma vida digna de ser vivida. A vida se desenvolve em dignidade mediante o acesso aos bens materiais e imateriais. As políticas do desenvolvimento humano, nesse sentido, devem se integrar a uma estrutura que apoie um crescimento com equidade e sustentabilidade. Palavras-chave: Pensamento complexo. Complexidade econômica. Direitos humanos. Desenvolvimento humano. Dignidade humana.

  16. Evaluation of radiology personnel practice of Mazandaran University of Medical Sciences

    International Nuclear Information System (INIS)

    Rahimi, S.A.

    2007-01-01

    Complete text of publication follows. Background and purpose: Radiology department that provides images with proper quality plays a vital role in diagnosis of diseases. Good image is obtained by proper technical criteria and correct Positioning. Personnel practice of radiology department has a principal role on radiographs quality. This study was carried out to determine the radiology department personnel practice in university hospitals. Method and Material: Data collection was made using an observational check list. Its validity and reliability was determined previously. The sample size of which was thirty-nine persons. 29 items of practice related to technical and protect ional aspects at three working shifts were observed and recorded separately. Results: Results showed that most of the personnel were female (61.5%), over 40 years old (59%) and technicians (53.8%). On the whole, personnel's score percentages in technical field on three shifts of morning evening and night were 47.5%, 46.2%, and 45.9%, respectively which were less than them in protect ional field (60.3%, 56A% and 55.8%, respectively). Comparison of technical protection and total scores related to individual variables showed significant difference only in organizational grades (p<0.0001, p<0.05, p<0.0001, respectively) Le. The mean scores of radiological technologists holding BSc and associate degrees were more than those of technologists not holding university degrees. Conclusion: The quality of the personnel practice is not desirable; therefore continuing education programmers are needed for personnel. Protection against radiation exposure, availability of equipment and continuous evaluation of use of equipment can be effective in dose reduction in patients.

  17. Implementation of a radiological safety management system in a hospital of Mexico City

    International Nuclear Information System (INIS)

    Martinez V, D.; Rivera M, T.; Velez D, V.

    2007-01-01

    Full text: The reflection of this work is based in some radiological accidents that its have happened in some hospital centers or of research. The over exposure of some people is due to the pursuit of the procedures, the lack of quality assurance of the equipment or the inappropriate actions of the technicians. In Mexico one has seen in several hospitals the lack of existence of a Quality Assurance Program to prevent the accidents, the execution of the same ones and those good practices and the lack of Safety Culture makes that the hospital radiological safety it is faulty. The objective of the present work is the implementation of a radiological safety management in a hospital of Mexico City. (Author)

  18. Technical basis for removal of 221-T tunnel from airborne radiological area status

    International Nuclear Information System (INIS)

    Geuther, W.J.

    1996-01-01

    This document provides the technical basis for removal of the 221-T Tunnel from airborne radiological control. T Plant Radiological Control has evaluated air sampling data and engineering controls, and determined the necessary administrative controls to make this transition. With these administrative controls (specified within document) in place, the tunnel can be removed from Airborne Radioactive Area status. The removal of the tunnel from airborne status will allow work to be performed within the tunnel under controlled conditions, as outlined in this technical basis, without the use of respiratory protection equipment

  19. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  20. Design principles for radiological protection instrumentation systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1981-02-01

    This Code of Practice takes the form of recommendations intended for designers and installers of Radiological Protection Instrumentation, and should also be of value to the newcomer to the R.P.I. field. Topics are discussed under the following headings: outline of R.P.I. requirements, specifying the requirement, satisfying the requirements, (overall design, availability and reliability, information display, human factors, power supplies, manufacture, quality assurance, testing, and cost analysis), supply, location and operation of the equipment, importance of documentation. (U.K.)

  1. Extended outlook: description, utilization, and daily applications of cloud technology in radiology.

    Science.gov (United States)

    Gerard, Perry; Kapadia, Neil; Chang, Patricia T; Acharya, Jay; Seiler, Michael; Lefkovitz, Zvi

    2013-12-01

    The purpose of this article is to discuss the concept of cloud technology, its role in medical applications and radiology, the role of the radiologist in using and accessing these vast resources of information, and privacy concerns and HIPAA compliance strategies. Cloud computing is the delivery of shared resources, software, and information to computers and other devices as a metered service. This technology has a promising role in the sharing of patient medical information and appears to be particularly suited for application in radiology, given the field's inherent need for storage and access to large amounts of data. The radiology cloud has significant strengths, such as providing centralized storage and access, reducing unnecessary repeat radiologic studies, and potentially allowing radiologic second opinions more easily. There are significant cost advantages to cloud computing because of a decreased need for infrastructure and equipment by the institution. Private clouds may be used to ensure secure storage of data and compliance with HIPAA. In choosing a cloud service, there are important aspects, such as disaster recovery plans, uptime, and security audits, that must be considered. Given that the field of radiology has become almost exclusively digital in recent years, the future of secure storage and easy access to imaging studies lies within cloud computing technology.

  2. Use of individual protection equipment and collective in case of accident during the transport of radioactive product - class 7

    International Nuclear Information System (INIS)

    Pastura, Valeria da F. e S.; Carvalho, Natanael Bruno de

    2013-01-01

    The personal protective equipment (PPE) are devices used by professionals against potential radiological hazards that may threaten the health or safety in the event of an accident or incident during the transport of radioactive material. The collective protection equipment (CPE) devices are used in place of the accident in order to protect people and the environment from risks such as safety signs, among others. This work will be part of the new edition of the NBR 9735 - Set of equipment for emergencies in land transport of dangerous goods - edited by the Brazilian Association of Technical Standards ABNT - National Standardization Forum which CNEN participates in the Study Committee - CB16 namely, dangerous, accounting for Class 7 radioactive materials. The Standard 9735 establishes the minimum set of equipment for emergencies in Inland transport of dangerous goods, consisting of protective equipment to be used by the driver and staff involved (if any) in the transport operations of transport units, equipment for signaling, isolation of the area of occurrence (fault, accident and/or emergency). Thus, we will present a set of individual and collective equipment that must accompany the carriage of Class 7 products to meet the radiological accident situations and also establish a training base for the driver as the use of them. (author)

  3. Medical equipment in government health facilities: missed opportunities.

    Science.gov (United States)

    Pardeshi, Geeta S

    2005-01-01

    The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. (1) To identify the problems in different stages of the life cycle. (2) To assess its financial implications and effect on service delivery. Analysis of secondary data from the latest Comptroller and Auditor General (CAG) Reports for the states in India. The study variables were category of equipment, financial implications and problems in the stages of life cycle. Calculation of proportions. A total of forty instances mentioning problems in the first phase of the life cycle of medical equipment were noted in 12 state reports. The equipment from the radiology department (15), equipment in the wards (5), laboratory (3) and operation theatres (4) were the ones most frequently implicated. In a majority of cases the financial implications amounted to twenty-five lakhs. The financial implications were in the form of extra expenditure, unfruitful expenditure or locking of funds. In 25 cases the equipment could not be put to use because of non-availability of trained staff and inadequate infrastructural support. Careful procurement, incoming inspection, successful installation and synchronization of qualified trained staff and infrastructural support will ensure timely onset of use of the equipment.

  4. Understanding Mechanisms of Radiological Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Rick Demmer; John Drake; Ryan James, PhD

    2014-03-01

    Over the last 50 years, the study of radiological contamination and decontamination has expanded significantly. This paper addresses the mechanisms of radiological contamination that have been reported and then discusses which methods have recently been used during performance testing of several different decontamination technologies. About twenty years ago the Idaho Nuclear Technology Engineering Center (INTEC) at the INL began a search for decontamination processes which could minimize secondary waste. In order to test the effectiveness of these decontamination technologies, a new simulated contamination, termed SIMCON, was developed. SIMCON was designed to replicate the types of contamination found on stainless steel, spent fuel processing equipment. Ten years later, the INL began research into methods for simulating urban contamination resulting from a radiological dispersal device (RDD). This work was sponsored by the Defense Advanced Research Projects Agency (DARPA) and included the initial development an aqueous application of contaminant to substrate. Since 2007, research sponsored by the US Environmental Protection Agency (EPA) has advanced that effort and led to the development of a contamination method that simulates particulate fallout from an Improvised Nuclear Device (IND). The IND method diverges from previous efforts to create tenacious contamination by simulating a reproducible “loose” contamination. Examining these different types of contamination (and subsequent decontamination processes), which have included several different radionuclides and substrates, sheds light on contamination processes that occur throughout the nuclear industry and in the urban environment.

  5. Situation of the radiological protection in hospitals of the Department the Freedom - Peru

    International Nuclear Information System (INIS)

    Gonzales Rojas, Jose Mercedes

    2001-01-01

    The present work is first one in this gener that it is made in the Department of the Freedom - Peru. The intention was to do a diagnose of the radiation protection in the sanitary scope taking into account some main parameters like the level of qualification of the worker occupational exposed, the design of environment and the quality of the equipment in aspects like: collimation, filtration, kV and time. In this study were taken into account the Hospitals of the Department of the Freedom that belong to the Ministry of Health, Social Security and Private Centers of Health. From each hospital a random sample of the radiology worker was taken and it was applied a survey with related questions to radiological safety. The gather of the information became by means of direct survey. The obtained results are very useful, because besides to make a real diagnose of the radiation protection, evaluating the human and technical factor, they serve to improve the aspects of quality in radiological diagnosis, since the conclusions allow to establish if it is counted on a suitable level of radiation protection on the part of the workers and if the equipment fulfills the quality necessary to reach an efficient use of x-rays

  6. Radiological protection report 2013; Strahlenschutzbericht 2013

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-06-15

    for the Swiss population as a whole of 5.5 mSv. The highest individual dose was below 11 mSv and affected one person. All doses received by persons professionally exposed to radiation and subject to ENSI surveillance were significantly less than the radiation limit. Increasing attention is being given to work in high and variable radiation fields and to those working in difficult conditions. ENSI has concluded that Swiss nuclear facilities continue to operate a consistent approach to radiological protection. Measuring equipment plays an extremely important role in radiological protection. Based on inspections and comparative measurements of aerosol and iodine filters and wastewater sampling together with measurements in the field of personal dosimetry, ENSI has concluded that the required calibrated measuring equipment for radiological protection exists, that this equipment is correctly used and provides reliable test data. For the purpose of monitoring environmental radioactivity, ENSI has operated a network that automatically monitors dose rates in the vicinity of nuclear power plants (MADUK). The results are made available to the Swiss National Emergency Operations Centre, the Ministry of the Environment in Baden-Wuerttemberg (Germany) and the European Radiological Data Exchange Platform (EURDEP). It is possible to deploy mobile lanthanum bromide detectors if MADUK registers an increase in dose rates. These detectors facilitate a gamma spectrum analysis in the event of a recorded increase. ENSI has maintained a test laboratory accredited under ISO 17025 that analyses samples from nuclear facilities and their immediate vicinity and also conducts field measurements. In the field of dispersion, hourly simulations are calculated based on current 3D wind precipitation fields as provided by MeteoSwiss with a spatial resolution of 2 km. These calculations, together with the annual aero-radiometric test flights, are a valuable and precise tool that can be used to analyse

  7. Radiological Worker Training: Radiological Worker 2 study guides

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable

  8. Optimizing diagnostic workup in the DRG environment: Dynamic algorithms and minimizing radiologic costs may cost your hospital money

    International Nuclear Information System (INIS)

    Saint-Louis, L.A.; Henschke, C.I.; Balter, S.; Whalen, J.P.; Balter, P.

    1987-01-01

    In certain diagnosis-related group (DRG) categories, the availability of sufficient CT scanners or of new equipment, such as MR equipment, can expedite the definitive workup. This will reduce the average length of stay and hospital cost. We analyzed the total hospital and radiologic charges by DRG category for all patients admitted to our hospital in 1985 and 1986. Although the cost per procedure is relatively high, the radiologic component is a small percentage of total hospital costs (median, 3%; maximum, <10%). The authors developed alternative diagnostic algorithms for radiologic-intensive DRG categories. Different diagnostic algorithms proposed for the same clinical problems were compared analytically in terms of impact on the hospital (cost, equipment availability, and length of stay). An example is the workup for FUO. Traditional approach uses plain x-rays and gallium scans and only uses CT when localizing symptoms are present. An alternative approach is to perform CT only. Although more CT examinations would be required, there is considerable reduction in the length of hospital stay and in overall charges. Neurologic and thoracic workups will be given as examples of classes or problems that can be addressed analytically: sequencing of the workup; prevalence; patient population; resource of allocation; and introduction of new imaging modality

  9. Gestão por processo e autonomia das equipes de trabalho

    OpenAIRE

    Laureto, José

    2003-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção. Este estudo teve por objetivo avaliar a autonomia de ação das equipes de processo para o atendimento das demandas dos clientes, com base na abordagem da organização orientada para processos. O alcance desse objetivo geral impôs o desenvolvimento de três outros específicos: 1) caracterização da organização e descrição do seu modelo de gestão; 2) descrição...

  10. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  11. Training in radiological protection - a pool of practical exercises

    International Nuclear Information System (INIS)

    Croft, J.R.; Hudson, A.P.

    1981-01-01

    Courses in Radiological Protection have been organised at Leeds by the NRPB since its formation, and prior to that by the Leeds Centre of the Radiological Protection Service. From the outset it seemed essential that such courses should contain a practical element, and accordingly a number of exercises were drawn up. Since that time further exercises have been added, often in response to a specific requirement from a customer or group of customers. Most of the exercises have involved the design and construction of 'one-off' items of equipment, a number of which can be considered to represent interesting approaches towards radiological protection teaching. The construction of a 'second generation' of hardware has focused attention on the objectives and design features of the exercises, which in turn has prompted a desire to publish a series of short papers describing the pool of exercises that is currently available for inclusion in the various courses run by the NRPB Centres. The first of these papers puts the series into context and provides a background to the descriptions of specific exercises. (author)

  12. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  13. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  14. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  15. Evaluation of conventional x-ray diagnostic equipment and radiological protection systems of hospitals and clinics installed in Recife city, Brazil; Avaliacao dos equipamentos de raios-X diagnostico convencionais e dos sistemas de protecao radiologica de clinicas e hospitais da cidade de Recife

    Energy Technology Data Exchange (ETDEWEB)

    Passos, Robson Silva

    1999-05-15

    Diagnostic radiology is the main contributor to the man-made exposure of general population. Since Quality Assurance (QA) programs ensure high quality diagnostic images with the lowest possible radiation dose to the patient, it has been recommended that all introduce QA programs for their radiological facilities. Consequently it is important to check the adequacy of equipment operating parameters in diagnostic radiography facilities, to ensure that a high quality of service is delivered. The purpose of this study was to evaluate the operating conditions of diagnostic units installed in Recife, Pernambuco. The study included 31 X-ray units from both public and private diagnostic services. The following parameters were evaluated: coincidence between the luminous and radiation fields; alignment of the radiation beam; agreement between the real and preset values of kVp and exposure time; filtration; half value lower (HVL); luminance of the view box; uniformity of the luminance; illuminance of the environment. The results showed that 20% of the equipment surveyed exhibited discrepancies between the luminous and radiation fields greater than 2% of the source to skin distance. The test of kilovoltage showed that 48% of the units do not fulfill the acceptability criteria, presenting discrepancies higher than {+-} 10% between the measured and preset values. The results of the accuracy of the timer indicated that 81% of the equipment surveyed present a discrepancy greater than {+-} 10% between the time selected in the control panel and actual exposure time.The test of the filtration shown that, in 20% of the equipment, this was inferior to 2,5 mm Al. The test of the luminance of view box shown that 96% of the equipment, shown a luminance lower of 2.000 cd/m{sup 2}. Related to the test of the uniformity of the luminance, 81 % of the equipment shown a variation of the uniformity higher then 10%. The test of the iluminancy of the environment shown that 61 % of the equipment

  16. Regulation of radiological protection for patients under radiodiagnosis

    International Nuclear Information System (INIS)

    Yacovenco, Alejandro; Ferreira, R.S.; Souza, A.C.A.

    1997-01-01

    Face to the increasing exposition of the population to ionizing radiations and the needs to fulfill user's rights, political and scientific efforts have been made in order to improve image quality and reduce risks to patients. A proposal to create a National Reference Laboratory to survey, supervise and evaluate the implementation of norms which require the control of physical parameters of the radiological equipment is presented. Aspects related to the profile of the Medical Physicist are also discussed. (author)

  17. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  18. Is PACS feasible for a major department of radiology

    International Nuclear Information System (INIS)

    Bautz, W.; Kolbe, J.

    1986-01-01

    Picture Archiving and Communication Systems (PACS) are getting more and more important for Departments of Radiology with the increasing spread of digital imaging methods. To determine the demands made on such systems, we calculated the digital image data volume for all examinations carried out in 1983 at the Department of Medical Radiology of the University of Tuebingen. 20.37% of all examinations were performed with digitalised equipment. Plain radiography takes the lion's share among the total number of image data. If digitalisation is based on a spatial resolution of 8 Lp/mm, the share is 98.4% of the total image data volume of 7123 GByte. This figure is far in excess of the estimates stated in literature. The possibilities of image data reduction and feasibility of a major PACS are discussed. (orig.) [de

  19. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. IV. - October of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  20. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. VI. - December of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  1. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. III. - September of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  2. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. V. - November of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  3. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. VI. - December of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  4. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. I. - July of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.

    2001-09-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  5. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. II.- August of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-10-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  6. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. IV. - October of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  7. Specialized consultant in radiological safety to the Salamanca regional hospital, PEMEX. II. - August of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Salamanca regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  8. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. III.- September of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-12-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  9. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. V. - November of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  10. Specialized consultant in radiological safety to the Tula general hospital, PEMEX. I.- July of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.

    2001-09-01

    The Tula general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic. The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  11. Evaluation of the use of personal protective equipment in radiodiagnostic services in Sergipe

    International Nuclear Information System (INIS)

    Santos, Lucas R. dos; Oliveira, Celso A.; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    The theme ionizing radiation is frequently associated with danger. Therefore this subject induces to think about accessories to personal protection. These accessories can contain metal heavy (as example, lead) so that we have an efficient protection. Our analysis was done with the main objective of evidence that is not enough the radiodiagnostic services have personal protective equipment to disposal to the radiology technicians have an efficient protection, because the procedures with ionizing radiation will be safe only with the use accomplish of the security procedures and of adequate use and storing of personal protective equipment. In our analysis the accessories in question were the lead rubber X-ray protection aprons and thyroid gland protectors. We have tested these accessories through of a similar methodology utilized to checking the half-value layer of the X-ray units. It was investigated also the importance given to use of these accessories by the radiology technicians. (author)

  12. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  13. Desenvolvimento humano: contribuições da psicologia moral

    Directory of Open Access Journals (Sweden)

    Yves de La Taille

    2007-03-01

    Full Text Available Procuramos avaliar as contribuições do conhecimento acumulado pela Psicologia Moral para a compreensão do desenvolvimento humano, para sustentar a tese segundo a qual a fonte energética do dever moral precisa ser procurada não só em sentimentos exclusivamente morais, mas também em sentimentos que desempenham um papel para o próprio desenvolvimento humano no seu conjunto. Três são os passos da análise deste artigo. Em primeiro lugar, verifi car se há possibilidade de articulação entre teorias psicológicas que enfatizam a dimensão afetiva da moralidade (Freud e Durkheim e outras que enfatizam a dimensão intelectual (Piaget e Kohlberg. Em segundo lugar, uma vez constatada a impossibilidade dessa articulação, sustentar que o sentimento de vergonha, presente na moralidade mas também em outras dimensões do desenvolvimento humano, é condição necessária ao sentimento de obrigatoriedade. Finalmente, analisar se tal sentimento é passível de ser evocado como fonte energética essencial nas abordagens que enfatizam a dimensão intelectual da moralidade.

  14. O desenvolvimento econômico da Venezuela, 1950/2006

    OpenAIRE

    Romina Batista de Lucena de Souza

    2008-01-01

    O objetivo desta tese é avaliar a contribuição do petróleo no desenvolvimento econômico da Venezuela, entre 1950/2006. Investiga-se por que uma economia rica em petróleo ainda não conseguiu industrializar-se. Seguindo os diferentes períodos governamentais, examinam-se a contribuição das políticas macroeconômicas sobre o desenvolvimento e a questão da doença holandesa e do capitalismo rentístico. Segundo a teoria da base econômica, as regiões crescem em torno de uma base exportadora, exercendo...

  15. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  16. Dosimetry in Diagnostic Radiology for Paediatric Patients

    International Nuclear Information System (INIS)

    2013-01-01

    Concern about the radiation dose to children from diagnostic radiology examinations has recently been popularly expressed, particularly as related to computed tomography (CT) procedures. This involves the observation that children can receive doses far in excess of those delivered to adults, in part due to the digital nature of the image receptors that may give no warning to the operator of the dose to the patient. Concern for CT examinations should be extended to the broad range of paediatric diagnostic radiological procedures responsible for radiation doses in children, especially as factors, such as increased radiosensitivity and the longer life expectancy of children, increase the associated radiation risk. In all cases, owing to the added paediatric radiological examination factor of patient size and its associated impact on equipment selection, clinical examination protocol and dosimetric audit, the determination of paediatric dose requires a distinct approach from adult dosimetry associated with diagnostic radiological examinations. In response to this, there is a need to inform health professionals about standardized methodologies used to determine paediatric dose for all major modalities such as general radiography, fluoroscopy and CT. Methodologies for standardizing the conduct of dose audits and their use for the derivation and application of diagnostic reference levels for patient populations, that vary in size, are also required. In addition, a review is needed of the current knowledge on risks specific to non-adults from radiation, and also an analysis of the management of factors contributing to dose from paediatric radiological examinations. In 2007, the IAEA published a code of practice, Dosimetry in Diagnostic Radiology: An International Code of Practice, as Technical Reports Series No. 457 (TRS 457). TRS 457 recommends procedures for dosimetric measurement and calibration for the attainment of standardized dosimetry, and addresses requirements

  17. Planos diretores: o caminho para o desenvolvimento sustentável das cidades

    Directory of Open Access Journals (Sweden)

    Alexsandro da Miranda

    2013-11-01

    Full Text Available Os Planos Diretores efetivam a existência de uma legislação geral estabelecendo as normas necessárias à implementação de políticas urbanas, previstas na Constituição Federal e no Estatuto da Cidade (Lei Federal 10.257/2001 e que em seu foco principal está o desenvolvimento e a expansão urbana.  Assim, o presente artigo aborda uma breve discussão teórica do tema, suas problemáticas e contextualizações na perspectiva de fundamentá-las à luz das teorias existentes. Três principais diretrizes devem ser destacadas: o desenvolvimento sustentável, a gestão democrática da cidade e o planejamento do desenvolvimento das cidades, onde os municípios, devem, portanto, utilizar as diretrizes e instrumentos do Estatuto da Cidade com o objetivo de estabelecer as regras que propiciem o pleno desenvolvimento econômico, social, ambiental e sustentável, com vistas a garantir o direito à cidade para todos os que nela vivem.

  18. Desenvolvimento econômico, desigualdade e saúde Economic development, inequality, and health

    Directory of Open Access Journals (Sweden)

    Pedro Reginaldo Prata

    1994-09-01

    Full Text Available O autor se refere a dimensão socioeconômica, individual e coletiva do fenômeno saúde-doença. Refere-se também ao fato das populações estarem sobre a influência desigual de fatores de risco e de proteção à saúde. Discute as desigualdades no desenvolvimento e a relação entre desenvolvimento, riqueza, saúde e justiça social. Questiona as teorias de desenvolvimento econômico, diferenciando desenvolvimento de crescimento. Cunha os conceitos de armadilha do desenvolvimento e refugiados sociais. Define uma comunidade saudável. Propõe a necessidade de mudança no modelo de desenvolvimento. Baliza o papel e as limitações do setor saúde no que diz respeito a iniqüidade social.The author refers to the social, economic, individual, and collective dimensions of the relationship between health and disease. He considers that individuals and populations are not equally exposed to protective and risk factors. He highlights the uneven development between nations and Brazilian regions, and communities, as well as discussing the relationship between development, wealth, health, and social justice. The article analyzes development theories and makes a distinction between economic development and growth. The concepts of development trap and social refugees are coined. The author defines a healthy community, points to the need for a shift in the current development model, and delineates the health sector's role and limitations in dealing with social inequality.

  19. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  20. Equipment recommendations for uniform work places for routine stomatological radiodiagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Rother, U [Rostock Univ. (German Democratic Republic). Radiologische Klinik; Taschner, P [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic); Wiltschke, F; Tonne, E; Kuehling, U; Nenning, K

    1977-03-01

    Corresponding to the different objectives, the Working Group on Radiology of the Stomatological Society has designed 6 standardized work places for routine radiodiagnosis in stomatology. Apart from the objectives, the problems related to the division of rooms, equipment, radioprotection and film processing are dealt with separately and specifically. The work places for routine stomatological radiodiagnosis are intended for achieving an improvement in a sector of stomatological care.

  1. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  2. Radiation protection and quality assurance in dental radiology: I. Intraoral radiography

    International Nuclear Information System (INIS)

    Martinez-Beneyto, Y.; Alcaraz, M.; Jodar-Porlan, S.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.

    2001-01-01

    This paper studies 2524 official reports on quality assurance in dental radiography, made in the context of the three first revisions of these dental clinics as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an intraoral device, making a special reference to the brands they have available, as well as their physical features (KV, mAs, filtration, length of cone) and the deviations detected in their operation. Some of the features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionizing radiation used in order to obtain the radiological image of the same tooth is presented. This paper shows, in a quantitative way, the characteristic features of intraoral dental radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)

  3. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    International Nuclear Information System (INIS)

    Supanich, M.

    2015-01-01

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists

  4. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Supanich, M. [Rush University Medical Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  5. Results of the independent radiological verification survey at the former Bridgeport Brass Company Facility, Seymour, Connecticut (SSC001)

    International Nuclear Information System (INIS)

    Foley, R.D.; Rice, D.E.; Allred, J.F.; Brown, K.S.

    1995-03-01

    At the request of the USDOE, a team from ORNL conducted an independent radiological verification survey at the former Bridgeport Brass Company Facility, Seymour, Connecticut, from September 1992 to March 1993. Purpose of the survey was to determine whether residual levels of radioactivity inside the Ruffert Building and selected adjacent areas were rmediated to levels below DOE guidelines for FUSRAP sites. The property was contaminated with radioactive residues of 238 U from uranium processing experiments conducted by Reactive Metals, Inc., from 1962 to 1964 for the Atomic Energy Commission. A previous radiological survey did not characterize the entire floor space because equipment which could not be moved at the time made it inaccessible for radiological surveys. During the remediation process, additional areas of elevated radioactivity were discovered under stationary equipment, which required additional remediation and further verification. Results of the independent radiological verification survey confirm that, with the exception of the drain system inside the building, residual uranium contamination has been remediated to levels below DOE guidelines for unrestricted release of property at FUSRAP sites inside and outside the Ruffert Building. However, certain sections of the drain system retain uranium contamination above DOE surface guideline levels. These sections of pipe are addressed in separate, referenced documentation

  6. RUP-pe : uma metodologia ágil, baseada no RUP e no TSP, para pequenas equipes

    OpenAIRE

    Pedro Carvalho de Oliveira, Joaquim

    2003-01-01

    Pesquisas recentes têm mostrado que projetos de software de curta duração e que utilizam equipes pequenas possuem maiores chances de sucesso. Entretanto, a escolha da metodologia a ser utilizada neste tipo de projeto deve levar em consideração suas características, como a comunicação facilitada e o menor grau de formalismo nos artefatos. Para se utilizar metodologias de desenvolvimento pesadas, como o RUP e o OPEN, deve-se fazer uma adaptação da metodologia escolhida, pois elas se propõem ser...

  7. DESENVOLVIMENTO DE RECURSOS DIDÁCTICOS INFORMATIZADOS NO ÂMBITO DA EDUCAÇÃO PARA O DESENVOLVIMENTO SUSTENTÁVEL. O EXEMPLO DO COURSEWARE SeRe

    Directory of Open Access Journals (Sweden)

    Patrícia Sá

    2010-02-01

    Full Text Available A falta de recursos didácticos informatizados de qualidade para o 1º e 2º Ciclos do Ensino Básico (1º/2º CEB, concebidos no âmbito da Educação para o Desenvolvimento Sustentável (EDS, numa perspectiva de Ensino por Pesquisa, determinou a organização de uma equipa multidisciplinar para o desenvolvimento do «Courseware Sere - O Ser Humano e os Recursos Naturais». Ajustando alguns princípios de desenvolvimento de software, particularmente de Design Centrado noUtilizador (DCU, o trabalho da equipa multidisciplinar, constituída por elementos com diversas competências (ao nível da Didáctica das Ciências, da Tecnologia Educativa, de Design e de Programação, centrou-se no desenvolvimento de um recurso didáctico informatizado que integra várias tipologias de software, nomeadamente simulações e visualizações, com as actividades didácticas. A orientação do recurso, as temáticas propostas e as metodologias e estratégias de exploração privilegiadas fundamentam-se: i na identificação das orientações nacionais e internacionais da EDS; ii na identificação das necessidades e interesses dos professores quanto à implementação de actividades com orientação EDS (Sá, 2008; Sá e Martins, 2007, iii no paradigma de ensino por competências (Cachapuz, Sá-Chaves e Paixão, 2004 e iv no recurso a um design interactivo centrado no utilizador (Costa, Loureiro, Reis, Sá, Guerra e Vieira, 2009; Guerra, 2007. Neste artigo faz-se uma apresentação do processo de desenvolvimento do recurso didáctico, das temáticas propostas e dasmetodologias e estratégias de exploração perspectivadas pelos autores do recurso.

  8. Evaluation of the practical peak voltage quantity for clinical equipment in diagnostic radiology

    International Nuclear Information System (INIS)

    Pires, Joao dos Santos Justo

    2007-01-01

    The objective of this work is to evaluate the calculation of the Practical Peak Voltage (PPV) from the voltage waveform and the kerma contrast for two kinds of X-ray equipment: a single phase clinical equipment, a three phase clinical equipment. The PPV from a mammography system voltage waveform will also be established. The development of this work involves intermediate objectives that indicate the quality of the used methods to calculate the PPV. One of these intermediate objectives is the comparison between the invasive calculations of PPV (using a voltage divider) with the response of kVp meter that calculate the PPV. Another intermediate objective is to compare the PPV with the Contrast Equivalent Voltage (the original non-invasive PPV definition). The variation of the PPV with quantities that influence in the voltage waveform like ripple and sample rate will also be contemplated in this work. The results showed that the PPV quantity could be invasive determined trustworthy. Therefore, the ripple quantity is the mainly influence to determinate the PPV that affecting the non-invasive determination. This fact suggest that the non-invasive instruments manufacturers must reevaluate the calculation of the PPV quantity in their instruments. (author)

  9. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  10. A mesoeconomia do desenvolvimento econômico: o papel das instituições

    Directory of Open Access Journals (Sweden)

    Huáscar Pessali

    2011-01-01

    Full Text Available O desenvolvimento econômico depende das instituições e as instituições, ao mesmo tempo, são uma medida do desenvolvimento econômico. Assim, correlação e causalidade se confundem num processo cumulativo e circular - uma espiral de mudanças que condiciona a ampliação das liberdades dos indivíduos. A contribuição pretendida por este ensaio é reunir e propor uma organização de várias idéias dispersas no tema "instituições e desenvolvimento econômico". Nossa releitura adiciona um breve exemplo da relação entre mercados, firmas e estado no âmbito do desenvolvimento. Isto permite defender o retorno a uma análise econômica que não se limite às falhas de mercado, mas que encare a responsabilidade de lidar com um emaranhado mais complexo de interações.

  11. European obesity and the radiology department. What can we do to help?

    International Nuclear Information System (INIS)

    Buckley, O.; Ward, E.; Colin, Walsh; Snow, A.; Ryan, A.; Torreggiani, W.C.

    2009-01-01

    Obesity is a chronic disease that is now a global epidemic. The numbers of obese people are exponentially rising in Europe, and it is projected that in Europe by 2010 there will be 150 million obese people. The obesity-related health crisis does not only affect adults, with one in four European children now overweight. Radiologists, both adult and paediatric, need to be aware of the magnitude of the problem, and obese patients cannot be denied radiologic evaluation due to their size. Missed diagnosis, appointment cancellation and embarrassing situations for patients when they are referred for a radiological examination for which they are not suitable are all issues that can be avoided if careful provision is made to accommodate the needs of the obese patient requiring radiologic evaluation. This paper will discuss the epidemiology of obesity and the role of radiology in the assessment of obesity and disorders of fat metabolism. The limitations obesity poses to current radiological equipment and how the radiologist can optimise imaging in the obese patient will be described. Dose reference levels and dose control are discussed. Examples of how obesity both hinders and helps the radiologist will be illustrated. Techniques and pre-procedural preparation to help the obese patient in the interventional suite are discussed. (orig.)

  12. European obesity and the radiology department. What can we do to help?

    LENUS (Irish Health Repository)

    Buckley, O

    2012-02-01

    Obesity is a chronic disease that is now a global epidemic. The numbers of obese people are exponentially rising in Europe, and it is projected that in Europe by 2010 there will be 150 million obese people. The obesity-related health crisis does not only affect adults, with one in four European children now overweight. Radiologists, both adult and paediatric, need to be aware of the magnitude of the problem, and obese patients cannot be denied radiologic evaluation due to their size. Missed diagnosis, appointment cancellation and embarrassing situations for patients when they are referred for a radiological examination for which they are not suitable are all issues that can be avoided if careful provision is made to accommodate the needs of the obese patient requiring radiologic evaluation. This paper will discuss the epidemiology of obesity and the role of radiology in the assessment of obesity and disorders of fat metabolism. The limitations obesity poses to current radiological equipment and how the radiologist can optimise imaging in the obese patient will be described. Dose reference levels and dose control are discussed. Examples of how obesity both hinders and helps the radiologist will be illustrated. Techniques and pre-procedural preparation to help the obese patient in the interventional suite are discussed.

  13. European obesity and the radiology department. What can we do to help?

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, O.; Ward, E.; Colin, Walsh; Snow, A. [Adelaide and Meath Hospital, Department of Radiology, Dublin (Ireland); Ryan, A. [Waterford Regional Hospital Co, Department of Radiology, Waterford (Ireland); Torreggiani, W.C. [Adelaide and Meath Hospital, Department of Radiology, Dublin (Ireland)]|[AMNCH, Dublin 24 (Ireland)

    2009-02-15

    Obesity is a chronic disease that is now a global epidemic. The numbers of obese people are exponentially rising in Europe, and it is projected that in Europe by 2010 there will be 150 million obese people. The obesity-related health crisis does not only affect adults, with one in four European children now overweight. Radiologists, both adult and paediatric, need to be aware of the magnitude of the problem, and obese patients cannot be denied radiologic evaluation due to their size. Missed diagnosis, appointment cancellation and embarrassing situations for patients when they are referred for a radiological examination for which they are not suitable are all issues that can be avoided if careful provision is made to accommodate the needs of the obese patient requiring radiologic evaluation. This paper will discuss the epidemiology of obesity and the role of radiology in the assessment of obesity and disorders of fat metabolism. The limitations obesity poses to current radiological equipment and how the radiologist can optimise imaging in the obese patient will be described. Dose reference levels and dose control are discussed. Examples of how obesity both hinders and helps the radiologist will be illustrated. Techniques and pre-procedural preparation to help the obese patient in the interventional suite are discussed. (orig.)

  14. The Spanish system for the radiological surveillance and control of scrap and the products resulting from its processing

    International Nuclear Information System (INIS)

    Gil, E.

    2001-01-01

    Despite the fact that the use of radiation technologies has always been subjected to strict controls in most countries, the presence of radioactive materials in scrap has been detected relatively often in recent years. This has led to the implementation of a series of international initiatives aimed at detecting and preventing illicit international trafficking with radioactive material, intentional or otherwise. The Spanish iron and steel industry is one of the most important industrial sectors in the country, and depends to a large extent on the importing of a significant proportion of the scrap its uses as raw material. Experience has shown that that countries that import large quantities of scrap should complement the aforementioned international initiatives with others of national scope, in order to reduce the risks arising from the presence of radioactive material in scrap. In this context, the Spanish radiological protection authorities, along with the business associations involved in the metal recovery and smelting industry, have established a national system for the radiological surveillance and control of scrap and of the products resulting from its processing. The system consists of a set of legal bases, the installation of specific radiological surveillance equipment and the enhancement of other general purpose equipment that existed prior to these initiatives, the development of radiological training and information plans for the professionals involved in the metal recovery and smelting sectors and improvement to the national radiological emergency response system. (author)

  15. O TRABALHO COMO ATIVIDADE PRINCIPAL NO DESENVOLVIMENTO PSÍQUICO DO INDIVÍDUO ADULTO

    Directory of Open Access Journals (Sweden)

    Camila Fernanda Moro Rios

    2017-12-01

    Full Text Available Este artigo visa analisar, por meio da revisão teórica de autores clássicos e contemporâneos da psicologia histórico-cultural, o trabalho como atividade principal na vida adulta, isto é, como a atividade que orienta as principais mudanças no psiquismo humano e na personalidade nessa idade. Para tanto, abstrai e generaliza elementos constantes nos estudos sobre periodização do desenvolvimento psíquico humano. Por um lado, identifica os conteúdos e processos psicológicos que, produzidos pelo trabalho, evidenciam sua relevância para o desenvolvimento do indivíduo adulto. Por outro, aborda os processos de alienação inerentes à sociedade capitalista, que alienam o trabalho como atividade principal. Assim, o trabalho se apresenta, dialeticamente, como atividade humanizadora e alienada. Entende-se que este estudo contribui para o avanço teórico-metodológico da psicologia histórico-cultural por abordar a questão do trabalho como atividade principal, uma discussão que se encontra ainda incipiente e pouco sistematizada. Além disso, supera o enfoque dos estudos sobre o desenvolvimento centrados na infância e reitera o rompimento com a perspectiva maturacionista de que a vida adulta é um período de estagnação do desenvolvimento. Pela análise do trabalho como atividade principal conclui-se que o desenvolvimento psicológico, produzido na vida adulta, se expressa, principalmente, por uma série de aquisições de habilidades e capacidades, pelo exercício da criatividade, por uma complexa reestruturação da esfera afetivo-motivacional da personalidade, pelo desenvolvimento da autoconsciência e pelo movimento dialético da consciência de classe, que tensiona a contradição entre o polo humanizador e o polo alienado/alienante do trabalho numa sociedade que limita e empobrece esse mesmo desenvolvimento.

  16. Microbiology for Radiologists: How to Minimize Infection Transmission in the Radiology Department.

    Science.gov (United States)

    Mirza, Sobia K; Tragon, Tyson R; Fukui, Melanie B; Hartman, Matthew S; Hartman, Amy L

    2015-01-01

    The implementation of standardized infection control and prevention practices is increasingly relevant as modern radiology practice evolves into its more clinical role. Current Centers for Disease Control and Prevention, National Institutes of Health, and World Health Organization guidelines for the proper use of personal protective equipment, decontamination of reusable medical equipment, and appropriate management of bloodborne pathogen exposures will be reviewed. Standard precautions apply to all patients at all times and are the mainstay of infection control. Proper hand hygiene includes washing hands with soap and water when exposed to certain infectious particles, such as Clostridium difficile spores, which are not inactivated by alcohol-based hand rubs. The appropriate use of personal protective equipment in accordance with recommendations from the Centers for Disease Control and Prevention includes wearing a surgical mask during lumbar puncture. Because radiologists may perform lumbar punctures for patients with prion disease, it is important to appreciate that incineration is the most effective method of inactivating prion proteins. However, there is currently no consensus recommendation on the decontamination of prion-contaminated reusable items associated with lumbar puncture, and institutional policies should be consulted for directed management. In the event of a needlestick injury, radiology staff must be able to quickly provide appropriate initial management and seek medical attention, including laboratory testing for bloodborne pathogens. ©RSNA, 2015.

  17. Quality and safety based management of radiological and clinical equipment

    International Nuclear Information System (INIS)

    Arora, S.; Saini, P.S.

    2001-01-01

    TQM (Total quality management) is the 'buzz' acronym expected in almost every aspect of industrial manufacturing, product development and services solicited by the outside agencies. The correct management of the many technological resources in health institutions in terms of efficiency, effectiveness and safety is a necessity in view of the criteria on which modern medicine is based. Almost all activities -be they diagnostic, therapeutic and rehabilitative - carried out within a modern hospital are based on widespread application of equipment and technology, the efficiency of which can directly influence the quality of service offered to the patient

  18. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  19. Bi-annual report 1994-1995. Research and operational activities of Central Laboratory for Radiological Protection

    International Nuclear Information System (INIS)

    1996-01-01

    BI-annual report of Central Laboratory for Radiological Protection, Warsaw, shows its activities in 1994-1995. The general information and organization of CLOR have been performed in the opening part of the report. The second part contains extended abstracts of scientific activities especially in: environmental radioactivity monitoring, supervision and control of the users of radioactive sources, dosimetry problems, calibration and standardization of dosimetric equipment, radiobiology and radiological hazard assessment. The report also includes the full list of publications of CLOR scientific staff issued in the period of 1994-1995

  20. Bi-annual report 1994-1995. Research and operational activities of Central Laboratory for Radiological Protection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    BI-annual report of Central Laboratory for Radiological Protection, Warsaw, shows its activities in 1994-1995. The general information and organization of CLOR have been performed in the opening part of the report. The second part contains extended abstracts of scientific activities especially in: environmental radioactivity monitoring, supervision and control of the users of radioactive sources, dosimetry problems, calibration and standardization of dosimetric equipment, radiobiology and radiological hazard assessment. The report also includes the full list of publications of CLOR scientific staff issued in the period of 1994-1995.

  1. Bi-annual report 1992-1993. Operational and research activities of Central Laboratory for Radiological Protection

    International Nuclear Information System (INIS)

    1994-06-01

    Bi-annual report of Central Laboratory for Radiological Protection, Warsaw shows its activities in 1992-1993. The general information and organization of CLOR have been shown in the first part of the report. The second part contains extended abstracts of scientific activity, especially in: environmental radioactivity monitoring, supervision and control of the users of radioactive sources, personal dosimetry, calibration and periodical control of dosimetric equipment, radiobiology and radiological hazard assessment. The report also includes the full list of publications of scientists of CLOR issued in the period of 1992-1993

  2. Bi-annual report 1992-1993. Operational and research activities of Central Laboratory for Radiological Protection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-06-01

    Bi-annual report of Central Laboratory for Radiological Protection, Warsaw shows its activities in 1992-1993. The general information and organization of CLOR have been shown in the first part of the report. The second part contains extended abstracts of scientific activity, especially in: environmental radioactivity monitoring, supervision and control of the users of radioactive sources, personal dosimetry, calibration and periodical control of dosimetric equipment, radiobiology and radiological hazard assessment. The report also includes the full list of publications of scientists of CLOR issued in the period of 1992-1993.

  3. Nevada Test Site Area 25. Radiological survey and cleanup project, 1974-1983. Final report

    International Nuclear Information System (INIS)

    McKnight, R.K.; Rosenberry, C.E.; Orcutt, J.A.

    1984-01-01

    This report describes radiological survey, decontamination and decommissioning of the Nevada Test Site (NTS) Area 25 facilities and land areas incorporated in the Nuclear Rocket Development Station (NRDS). Buildings, facilities and support systems used after 1959 for nuclear reactor and engine testing were surveyed for the presence of radioactive contamination. The cleanup was part of the Surplus Facilities Management Program funded by the Department of Energy's Richland Operations Office. The radiological survey portion of the project encompassed portable instrument surveys and removable contamination surveys (swipe) for alpha and beta plus gamma radiation contamination of facilities, equipment and land areas. Soil sampling was also accomplished. The majority of Area 25 facilities and land areas have been returned to unrestricted use. Remaining radiologically contaminated areas are posted with warning signs and barricades. 12 figures

  4. Specialized consultant in radiological safety to the Reforma peripheral clinic, PEMEX. - I. - May-June of 2003

    International Nuclear Information System (INIS)

    Torres P, A.; Garcia A, J.; Rodriguez A, F.

    2003-07-01

    The Reforma peripheral clinic, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the clinic can conserve its respective sanitary license.(Author)

  5. Presentation of the main regulatory provisions applicable in medical and dental radiology

    International Nuclear Information System (INIS)

    2010-01-01

    The aim of this document is to give an overview of the regulation framework to physicians, radiologists, dental surgeons, medical personnel employers, and persons with abilities in radioprotection. It addresses the procedures of declaration and authorization of possession and use of electric equipment generating ionizing radiation, the different persons intervening to ensure the radioprotection of patients and workers, the laying-out conditions for a radiology installation, the different aspects of population and worker radioprotection and of patient radioprotection, the maintenance and quality control of medical equipment, the declaration of incidents at the ASN, and radioprotection inspection

  6. The basis for a radiological protection program to the health area of the State University of Campinas (UNICAMP)

    International Nuclear Information System (INIS)

    Coelho, Rosangela Franco.

    1994-01-01

    There are some sectors in the Health Area of the State University of Campinas (UNICAMP) that present great potential risks from the viewpoint of radiation protection. The aim of this work is to establish the basis a radiological protection program applicable to these sectors. The Diagnostic Radiology Services and the Laboratory of Cardiac Catheterization of the Hospital de Clinicas have been analyzed, as well as the Radiotherapy Services of the Center for Integral Assistance to the Women Health (CAISM). This work was mainly supported by national and international regulations related to the operative and employment aspects of the equipment and radiation sources used in the health area. Regulations related to area and individual monitoring of workers were also used. Results show that the interior of the rooms where the equipment and radiation sources are located is classified as controlled area, whereas the neighborhoods of the rooms are mostly free areas. In order to improve the radiological protection conditions, only some of the operative and employment aspects need to be modified regarding equipment and radiation sources. In this way, routine personal monitoring would not be further required. Since all the workers have their annual mean equivalent doses below 3/10 of the primary limits of the applicable equivalent dose, routine individual monitoring could be exempted. (author). 23 refs., 51 figs., 83 tabs

  7. Calibration of the indicators of the product KERMa-AREA in radiodiagnostic equipment

    International Nuclear Information System (INIS)

    Ginjaume, M.; Jarvinen, H.; Turak, O.

    2013-01-01

    Currently the IAEA proposes two procedures for the calibration of the determination of the PKA systems integrated in the x-ray equipment. The traditional method is to measure air kerma at a certain distance from the focus through an ionization chamber reference and then the area of the field of radiation in that position. The alternative method is based on measuring directly the product kerma-area using equipment calibrated in this magnitude. In both cases the calibration procedure takes into account the position of the tube on the stretcher of the patient. The objective of this study was to compare the practical application of both calibration procedures as well as assess the accuracy of indication of the PKA in the consoles of the radiology equipment. (Author)

  8. Lists A and B of X-ray equipment. As of July 1, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    The lists A and B of X-ray equipment present the guidelines for X-ray device, as of December 10, 1983, that are defined in the guidelines for radiology and nuclear medicine of the Federal Association of Panel Doctors. In list A, the equipment categories of up-to-date, commercially available X-ray device are given, whereas list B classifies older equipment, both types available from manufacturers who are members of the ZVEI association. Since the categories of application II and III have been made, specifiying the equipment still in use and applicable within a given transitional period in existing medical establishments, but which may not be applied in new establishments. The list of manufacturers gives the addresses of the firms supplying the equipment described in Lists A and B, which have been compiled according to the requirements set by the Federal Association of Panel Doctors. (orig.) [de

  9. Repository National Institutes for Quantum and Radiological Science and Technology (QST)

    International Nuclear Information System (INIS)

    Maeda, Takamasa

    2016-01-01

    This paper introduces the facilities of National Institute of Radiological Sciences (NIRS). It was established as an auxiliary organ of the Science and Technology Agency in 1957. In April 2016, it became a comprehensive radiology research and development department of the Quantum Science and Technology Research Organization, and has been performing 'research for medical use of radiation' and 'research for radiation safety and emergency radiation medical care' as the two pillars of research. The laboratory hospital is a sole monotechnic radiation hospital in Japan specializing in radiotherapy. Heavy particle accelerator for medical use has been constructed, and advancement of heavy particle therapy using rotating gantry is expected. At the clinical nuclear medicine department, research facilities involved in molecular imaging are cyclotron building, positron building, imaging diagnostic building, and exploratory research building, and they are equipped with are three large and small cyclotrons, clinical PET device, animal-specialized PET device, 7-tesla MRI. The nuclear medicine laboratory is equipped with four PET/CT devices, one PET device, and one gamma camera, and performing tumor examination and clinical research on psychiatric and neurological diseases. (A.O.)

  10. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  11. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  12. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  13. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  14. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  15. Radiological characterisation of V1 NPP technological systems and buildings - Activation

    International Nuclear Information System (INIS)

    Kristofova, Kristina; Rapant, Tibor; Svitek, Jaroslav

    2012-01-01

    V1 NPP at Jaslovske Bohunice site has been finally shutdown after 28 years of successful operation in 2006 (Unit 1) and 2008 (Unit 2). At present, both units are finally shutdown and since July 2011 under decommissioning license. The preparation of V1 NPP decommissioning has been supported and partly financed by the Bohunice International Decommissioning Support Fund (BIDSF), under the administration of the European Bank for Reconstruction and Development. From 06/2008 to 12/2011 AMEC Nuclear Slovakia, together with partners STM Power and EWN GmbH, carried out BIDSF B6.4 project - Decommissioning database development (DDB). The main purpose of the B6.4 project was to develop a physical and radiological inventory database to support V1 NPP decommissioning process planning and performance. One of the specific deliverable tasks within the B6.4 project was deliverable D12 - Characterization of activated equipment and civil structures based on measurement, sampling and analyses performed on the samples. The scope of deliverable services within D12 task consisted of: 1. Categorization of activated components ; 2. Development of single working programs for their radiological monitoring and sampling ; 3. Preparation of sampling device and revision of all handling equipment; 4. Dose rate monitoring and sampling of: - Civil structures from reactors shaft on both units ; - Components placed in HLW storage, (so called 'Mogilnik') - connection rods, absorbers ; of control rod assemblies and neutron flux measurement channels ; - Reactor pressure vessel and shielding assemblies at both units of V1 NPP, reactor; internals from Unit 2 of V1 NPP; 5. Analysis of samples ; 6. Determination of radiological inventory ; 7. Import of radiological data for activated components into DDB. During sampling, mainly remotely controlled sampling device and radiation resistant camera with LED lightening for visual checking of all performed activities was used. In total, 125 samples have been taken

  16. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    International Nuclear Information System (INIS)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-01-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  17. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games.

    Science.gov (United States)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-10-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9% were magnetic resonance imaging (MRI) scans, 22% were diagnostic ultrasound (US) examinations, 33.1% were radiographs, 4.3% were computed tomography (CT) scans and 2.7% were imaging-guided interventional procedures. 88% of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events.

  18. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    Energy Technology Data Exchange (ETDEWEB)

    Bethapudi, Sarath [County Durham Darlington Foundation NHS Trust, Durham (United Kingdom); Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Ritchie, David [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Greater Glasgow and Clyde Hospitals NHS Trust, Western Infirmary, Glasgow (United Kingdom); Bongale, Santosh [Glasgow 2014 Commonwealth Games, Immediate Care Department, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Royal Alexandra Hospital, Paisley (United Kingdom); Gordon, Jonny [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Glasgow (United Kingdom); MacLean, John [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); National Stadium Sports Medicine Centre, Glasgow (United Kingdom); Mendl, Liz [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom)

    2015-10-15

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  19. Regulation EM-GT-8. Guidance for quality control of mammography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Objective: To provide practical guidance of technical procedures for carrying out quality control in mammography equipment. Scope: This guide applies to mammography equipment. A number of methods which require the appointed instrumentation described, some of which can be implemented in radiology services own country given the low complexity of themselves and others that require specific equipment and can be performed by specialized groups external to these units. The guide does not constitute a mandatory, however, the parameters evaluated according to the tests described therein and their tolerances form the basis of regulations that establish the CCEEM about these teams. Overview: The success of mammographic studies depends on obtaining high-quality images combined with a low rate of patient dose. To ensure this objective the establishment of quality assurance programs on all aspects involving these services is necessary. This guide provides a number of quality control procedures aimed at x-ray equipment, which must be performed at least on an annual basis or when some maintenance occurs at x-ray equipment.

  20. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  1. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Not only are acceptance criteria directly related to the design of medical x-ray equipment and quality assurance exercised during its manufacture, but also its performance, safety and reliability must feature in requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. In the UK quality of maintenance services has been considered by one of our Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment in the National Health Service. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes complementary duties of contractors and customers. Radiograph reject analysis has indicated human error outweighs unsatisfactory equipment performance as the reason for rejecting poor radiographs. The use in X-ray departments of the kind of manufacturing quality system used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure. (author)

  2. Radiological skull diagnosing - questions of the neurosurgeon to the radiologist

    International Nuclear Information System (INIS)

    Fahlbusch, R.; Hamburger, C.; Ringel, K.

    1982-01-01

    A well-adjusted overall picture of the skull is very important to the neurosurgeon for diagnosis and therapy. Without an overall picture of the skull the neurosurgeon is hardly likely to begin a trepanation. There are, however, still same questions open in radiological diagnostics. A solution of the problem might be offered soon by computerized radiography which might even replace the conventional X-ray examination of the skull. The radiological CT-total skeletal examination of polytraumatised patients, which can be carried out in 30 seconds by modern CT equipment makes it possible to also obtain overall pictures of the skull and the upper cervical vertebral column. An advantage in addition to the fast information is the significant reduction of the radiation exposure in comparison to conventional methods. (orig./APR) [de

  3. Introduction of new terms and lessons for radiological protection after Fukushima Dai-Ichi accident

    International Nuclear Information System (INIS)

    Singh, Vishwanath P.; Managanvi, S.S.; Bhat, H.R.

    2012-01-01

    The nuclear accidents in the world are very few among various types of operating facilities. However when an accident happened, we have learnt a lot to improve the philosophy, term, definitions, document preparation, equipment's requirement, supporting systems, awareness program and restriction etc. After Fukushima Dai-ichi we have learnt a lot, in this view this paper has been prepared to discuss for radiological protection aspects. Discussion: The probability of nuclear accidents is negligible but when happens, it opens new doors of lessons for radiological protection practices for occupational workers, emergency workers for damage control to prevent catastrophic situation/rescue to life saving actions and the member of the public. The Chernobyl and Three Mile Island accidents have provided a lot experiences for management of emergency situations, documentation, radiation emergency preparedness, emergency equipment's, concept of defense-in-depth, emergency planning zone (EPZ), accidental dose limits, estimation of source term and public dose, intervention levels, decision supporting system, remedial actions in public domain; decontamination of person, houses/building and land and etc. Recent Fukushima Dai-ichi accident in Japan was managed in appreciable manner but still new definitions and lessons for radiological protection have been emerged out. The present paper discusses difficulties w. r. t. the radiological aspects observed/faced by Japanese during nuclear crises. The accident introduced new terms as Natural Dose Rate Unit (NDRU), voluntary evacuation, deliberate evacuation area, restricted area and difference between evacuation zone and EPZ. The Fukushima accident has enforced worldwide regulators and operators to review the individual dose limit and amendment for raise in the dose limit during accident, availability of efficient/adequate quantities of personal dosimeter in public domain, collection arrangement of bulk amount of radioactive wastes

  4. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  5. Medical SisRadiologia: a new software tool for analysis of radiological accidents and incidents in medical radiology

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da, E-mail: araujocamila@yahoo.com.br, E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Araujo, Rilton A.; Pelegrineli, Samuel Q., E-mail: consultoria@maximindustrial.com.br, E-mail: samuelfisica@maximindustrial.com.br [Maxim Industrial, Rio de Janeiro, RJ (Brazil)

    2013-07-01

    The man's exposure to ionizing radiation in health are has increased considerably due not only the great request of medical examinations as well as the improvement of the techniques used in diagnostic imaging, for example, equipment for conventional X-rays, CT scans, mammography, hemodynamic and others. Although the benefits of using of radiology techniques are unquestionable, the lack of training in radiation protection of the workers, associated with procedure errors, have been responsible for the increasing number of radiation overexposures of these workers. Sometimes these high doses are real and there is a true radiological accident. The radiation workers, named occupationally Exposed Individual (IOE), must comply with two national regulations: Governmental Decree 453/1998 of the National Agency of Sanitary Surveillance (Portaria 453/1998 ANVISA Agencia Nacional de Vigilancia Sanitaria), which establishes the basic guidelines for radiation protection in medial and dental radiology and; the Governmental Decree NR-32/2002 of the Ministry of Labour and Employment (Ministerio do Trabalho e Emprego), which establishes the basic guidelines for the worker's health. The two mandatory regulations postulate a detailed investigation in the event of radiation overexposure of an IOE. In order to advice the diagnostic institution to perform an efficient analysis, investigation and report of high doses, it is proposed the use of a computational tool named 'Medical SisRadiologia'. This software tool enables the compilation and record of radiological abnormal data occurred in a diagnostic institution. It will also facilitate the detailed analysis of the event and will increase the effectiveness and development of work performed by the Radiation Protection Service. At the end, a technical report is issued, in accordance with the regulations of the technical regulations, which could also be used as training tool to avoid another event in the future. (author)

  6. Medical SisRadiologia: a new software tool for analysis of radiological accidents and incidents in medical radiology

    International Nuclear Information System (INIS)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da; Araujo, Rilton A.; Pelegrineli, Samuel Q.

    2013-01-01

    The man's exposure to ionizing radiation in health are has increased considerably due not only the great request of medical examinations as well as the improvement of the techniques used in diagnostic imaging, for example, equipment for conventional X-rays, CT scans, mammography, hemodynamic and others. Although the benefits of using of radiology techniques are unquestionable, the lack of training in radiation protection of the workers, associated with procedure errors, have been responsible for the increasing number of radiation overexposures of these workers. Sometimes these high doses are real and there is a true radiological accident. The radiation workers, named occupationally Exposed Individual (IOE), must comply with two national regulations: Governmental Decree 453/1998 of the National Agency of Sanitary Surveillance (Portaria 453/1998 ANVISA Agencia Nacional de Vigilancia Sanitaria), which establishes the basic guidelines for radiation protection in medial and dental radiology and; the Governmental Decree NR-32/2002 of the Ministry of Labour and Employment (Ministerio do Trabalho e Emprego), which establishes the basic guidelines for the worker's health. The two mandatory regulations postulate a detailed investigation in the event of radiation overexposure of an IOE. In order to advice the diagnostic institution to perform an efficient analysis, investigation and report of high doses, it is proposed the use of a computational tool named 'Medical SisRadiologia'. This software tool enables the compilation and record of radiological abnormal data occurred in a diagnostic institution. It will also facilitate the detailed analysis of the event and will increase the effectiveness and development of work performed by the Radiation Protection Service. At the end, a technical report is issued, in accordance with the regulations of the technical regulations, which could also be used as training tool to avoid another event in the future. (author)

  7. Guidance levels for diagnostic radiology in Romania

    International Nuclear Information System (INIS)

    Iacob, O.; Diaconescu, C.

    2002-01-01

    Over two decades surveys of radiological practice in Romania have demonstrated wide variations in patient dose levels between different hospitals. Local and national investigations revealed poor performances as well as of radiological equipment, darkroom procedure or technology of investigation. Hitherto, the annual collective effective dose to the population of Romania from diagnostic medical exposures attained a value of 13,820 manSv. Since the annual frequencies of radiological examinations remain unchanged over last ten years, this value is mostly attributed to the individual dose levels in different X-ray procedures. Notwithstanding the huge benefits to patients, the reduction of unnecessary exposures and individual doses are our principal concern and the establishment of national reference dose levels should solve this problem. British experience demonstrated that reference doses are a practical tool in this purpose and the adoption of national reference dose values indicated an overall improvement in patient exposure. Even the local of reference dose values proved a useful way to achieve patient dose reduction. In meantime the optimization of patient protection, each X-ray examination should be conducted with lowest necessary dose to achieve the clinical aim. This paper presents the first approach to establish local reference dose levels for some diagnostic examinations based on the measurements made in six (from the eighth of Eastern territory of Romania) districts, invited to cooperate in this end

  8. O coaching enquanto prática de desenvolvimento de recursos humanos

    OpenAIRE

    Soares, Luciana Rocha

    2013-01-01

    A presente investigação visa identificar os benefícios do coaching para o desenvolvimento de recursos humanos, procurando entender como esta prática contribui para o desenvolvimento de competências, para a melhoria de desempenhos e resultados organizacionais. Sendo uma pesquisa de natureza qualitativa, foram realizadas entrevistas semiestruturadas a 10 coaches profissionais, as quais foram submetidas a análise de conteúdo. Não representativos da população, os resultados obti...

  9. Radiological anatomy - evaluation of integrative education in radiology.

    Science.gov (United States)

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Analysis of the Radiology Reports from Radiology Clinics

    International Nuclear Information System (INIS)

    Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho

    2009-01-01

    The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians

  11. Desenvolvimento Policêntrico na Europa : Uma reflexao critica sobre um conceito de politicas normativas

    NARCIS (Netherlands)

    Meijers, E.J.

    Durante a última década, o desenvolvimento policêntrico tornou-se um conceito-chave no desenvolvimento territorial europeu. Em muitos aspectos, é um conceito difuso que significa diferentes coisas para diferentes pessoas em diferentes escalas espaciais. Neste artigo, analisamos as variadas

  12. Buildings radiological characterization report for the Weldon Spring Site Remedial Action Project, Weldon Spring, Missouri

    International Nuclear Information System (INIS)

    1990-04-01

    This report summarizes radiological characterization data on the Weldon Spring Chemical Plant (WSCP) buildings gathered as part of five previous investigations, and provides a consistent will be used to support future feasibility studies which will determine the best available technologies for ultimate disposition of the buildings and associated equipment. At present no structure or piece of equipment can be released from the WSCP for unrestricted use without further radiation measurements being performed. A final group of equipment and building components contains surface radioactivity levels in excess of DOE guidelines; this group, usually found in buildings housing uranium and/or thorium processing equipment, will require decontamination and comprehensive scanning in order to be considered for unrestricted use release. 9 refs., 44 tabs

  13. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    Science.gov (United States)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  14. Status of radiation protection in interventional radiology. Assessment of inspections in 2009 by the ASN

    International Nuclear Information System (INIS)

    2011-01-01

    This report first describes the organization of inspections performed in health institutions, indicates the inspected establishments, the types of fixed installations in interventional radiology, the use of imagery in the operating theatre, and discusses the regulatory arrangements applicable to interventional radiology (in the Public Health Code, in the Labour Code). Then, the report discusses the results of inspections regarding radiation protection in interventional radiology: application of public health code arrangements (justification, patient training in radiation protection, radiological procedures and protocols, patient dosimetry monitoring), application of Labour Code arrangements (designation of the person with expertise in radiation protection, risk assessment and delimitation of monitored and controlled areas, workstation analysis, workers' training in radiation protection, individual protection equipment, workers' dosimetric monitoring, workers' medical monitoring, radiation protection technical controls), significant events, radiation protection in operating theatre. Propositions are stated regarding the differences noticed within or between the health establishments, the methodological and organisational difficulties faced by persons with expertise in radiation protection (PCR), the need of an interdisciplinary team

  15. Introduction of radiological protection; Pengenalan kepada perlindungan radiologi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: basic principles of radiological protection , dose limit which was suggested, stochastic and nonstochastic effects, equivalent dose and alternative of it`s calculation, limit for the publics, ICRP (International Commission for Radiological Protection) recommendations, and the principles of radiological protection. Dangerous radiation sources also briefly summarized i.e. x-ray generators, reactor nucleus.

  16. Development of archetypes of radiology for electronic health record; Desenvolvimento de arquetipos de radiologia para registro eletronico de saude

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Tiago V.; Pires, Silvio R.; Paiva, Paulo B., E-mail: tiago.veloso@unifesp.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Dept. de Informatica em Saude

    2013-08-15

    This paper presents a proposal to develop archetypes for electronic patient records system based the openEHR Foundation model. Archetypes were developed specifically for the areas of radiology and diagnostic imaging, as for the early implementation of an electronic health records system. The archetypes developed are related to the examinations request, their execution and report, corresponding to both the administrative as diagnostic workflow inside a diagnostic imaging sector. (author)

  17. Specialized consultant in radiological safety to the Reforma peripheral clinic, PEMEX. - III. - September and October of 2002

    International Nuclear Information System (INIS)

    Angeles C, A.; Rodriguez A, F.; Garcia A, J.

    2003-02-01

    The Reforma peripheral clinic, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the clinic can conserve its respective sanitary license.(Author)

  18. Specialized consultant in radiological safety to the Macuspana peripheral clinic, PEMEX. - IV. - November and December of 2002

    International Nuclear Information System (INIS)

    Angeles C, A.; Hernandez C, J. E.; Garcia A, J.; Rodriguez A, F.

    2003-02-01

    The Macuspana peripheral clinic, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the clinic can conserve its respective sanitary license.(Author)

  19. Specialized consultant in radiological safety to the Villahermosa regional hospital, PEMEX. IV. - November and December of 2002

    International Nuclear Information System (INIS)

    Angeles C, A.; Hernandez C, J.E.; Rodriguez A, F.; Garcia A, J.

    2003-02-01

    The Villahermosa regional hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  20. Indicators of the management for the continuous improvement of the radiological safety in a radioactive facility

    International Nuclear Information System (INIS)

    Amador B, Z. H.

    2006-01-01

    The use of safety indicators is common in the nuclear industry. In this work the implementation of indicators for the efficiency analysis of the radiological safety management system of a radioactive installation is presented. Through the same ones the occupational exposure, the training Y authorization of the personnel, the control of practices Y radioactive inventory, the results of the radiological surveillance, the occurrence of radiological events, the aptitude of the monitoring equipment, the management of the radioactive waste, the public exposure, the audits Y the costs of safety are evaluated. Its study is included in the periodic training of the workers. Without this interrelation it is not possible to maintain the optimization of the safety neither to achieve a continuous improvement. (Author)

  1. How to optimize radiological images captured from digital cameras, using the Adobe Photoshop 6.0 program.

    Science.gov (United States)

    Chalazonitis, A N; Koumarianos, D; Tzovara, J; Chronopoulos, P

    2003-06-01

    Over the past decade, the technology that permits images to be digitized and the reduction in the cost of digital equipment allows quick digital transfer of any conventional radiological film. Images then can be transferred to a personal computer, and several software programs are available that can manipulate their digital appearance. In this article, the fundamentals of digital imaging are discussed, as well as the wide variety of optional adjustments that the Adobe Photoshop 6.0 (Adobe Systems, San Jose, CA) program can offer to present radiological images with satisfactory digital imaging quality.

  2. Radiological imaging of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Quaia, Emilio (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Ist. Radiologia

    2011-07-01

    This book provides a unique and comprehensive analysis of the normal anatomy and pathology of the kidney and upper urinary tract from the modern diagnostic imaging point of view. The first part is dedicated to the embryology and normal radiological anatomy of the kidney and anatomic variants. The second part presents in detail all of the imaging modalities which can be employed to assess the kidney and the upper urinary tract, including ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography. Patient preparation and investigation protocols are accurately described, and the principal fields of application of each imaging modality are clearly highlighted. The entire spectrum of kidney pathologies is then presented in a series of detailed chapters. Each pathology is illustrated by high-quality images obtained with state of the art equipment and the most advanced imaging modalities, as well as by figures showing macroscopic and microscopic specimens. The latest innovations in interventional radiology, biopsy procedures, and parametric and molecular imaging are also described, as is the relationship between contrast media and kidney function. This book will be of great interest to all radiologists, oncologists, and urologists who are involved in the management of kidney pathologies in their daily clinical practice. (orig.)

  3. Radiological imaging of the kidney

    International Nuclear Information System (INIS)

    Quaia, Emilio

    2011-01-01

    This book provides a unique and comprehensive analysis of the normal anatomy and pathology of the kidney and upper urinary tract from the modern diagnostic imaging point of view. The first part is dedicated to the embryology and normal radiological anatomy of the kidney and anatomic variants. The second part presents in detail all of the imaging modalities which can be employed to assess the kidney and the upper urinary tract, including ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography. Patient preparation and investigation protocols are accurately described, and the principal fields of application of each imaging modality are clearly highlighted. The entire spectrum of kidney pathologies is then presented in a series of detailed chapters. Each pathology is illustrated by high-quality images obtained with state of the art equipment and the most advanced imaging modalities, as well as by figures showing macroscopic and microscopic specimens. The latest innovations in interventional radiology, biopsy procedures, and parametric and molecular imaging are also described, as is the relationship between contrast media and kidney function. This book will be of great interest to all radiologists, oncologists, and urologists who are involved in the management of kidney pathologies in their daily clinical practice. (orig.)

  4. Método Ágil aplicado ao desenvolvimento de software confiável baseado em componentes

    OpenAIRE

    Alan Braz

    2013-01-01

    Resumo: Os Métodos Ágeis, ou Desenvolvimento Ágil de Software (DAS), tem se popularizado, na última década, por meio de métodos como Extreme Programming (XP) e Scrum e isso fez com que fossem aplicadas no desenvolvimento de sistemas computacionais de diversos tamanhos, complexidades técnica e de domínio, e de rigor quanto à confiabilidade. Esse fato evidencia a necessidade de processos de desenvolvimento de software que sejam mais rigorosos e que possuam uma quantidade adequada de modelagem e...

  5. O desenvolvimento do conhecimento na Pesquisa e Desenvolvimento e o registro através de patentes no Brasil – uma experiência profissional

    Directory of Open Access Journals (Sweden)

    Cynthia Helena Soares Bouças Teixeira

    2017-11-01

    Full Text Available Este trabalho tem como objetivo fornecer um detalhamento sobre o processo de busca do conhecimento, partindo de uma ferramenta básica que é a informação. No contexto que envolve Pesquisa & Desenvolvimento, o conhecimento pode ser estruturado para o desenvolvimento de novas tecnologias, produtos ou processos, em que o registro do conhecimento pode ocorrer  através das patentes. Dado que é preciso conhecer a legislação do país de depósito,trataremos mais especificamente do sistema de registro de patentes brasileiro denominado Instituto Nacional da Propriedade Intelectual – INPI. As reflexões apresentadas são provenientes de uma experiência profissional.

  6. Diversity Matters in Academic Radiology: Acknowledging and Addressing Unconscious Bias.

    Science.gov (United States)

    Allen, Brenda J; Garg, Kavita

    2016-12-01

    To meet challenges related to changing demographics, and to optimize the promise of diversity, radiologists must bridge the gap between numbers of women and historically underrepresented minorities in radiology and radiation oncology as contrasted with other medical specialties. Research reveals multiple ways that women and underrepresented minorities can benefit radiology education, research, and practice. To achieve those benefits, promising practices promote developing and implementing strategies that support diversity as an institutional priority and cultivate shared responsibility among all members to create inclusive learning and workplace environments. Strategies also include providing professional development to empower and equip members to accomplish diversity-related goals. Among topics for professional development about diversity, unconscious bias has shown positive results. Unconscious bias refers to ways humans unknowingly draw upon assumptions about individuals and groups to make decisions about them. Researchers have documented unconscious bias in a variety of contexts and professions, including health care, in which they have studied differential treatment, diagnosis, prescribed care, patient well-being and compliance, physician-patient interactions, clinical decision making, and medical school education. These studies demonstrate unfavorable impacts on members of underrepresented groups and women. Learning about and striving to counteract unconscious bias points to promising practices for increasing the numbers of women and underrepresented minorities in the radiology and radiation oncology workforce. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Nutrição e desenvolvimento Nutrition and development

    Directory of Open Access Journals (Sweden)

    Ilma K. G. de Arruda

    1994-09-01

    Full Text Available As discussões sobre desenvolvimento e nutrição freqüentemente se realizam sob um duplo enfoque: aqueles que consideram o estado nutricional como reflexo do desenvolvimento, e os que admitem que a nutrição influencia fortemente no nível e ritmo desse desenvolvimento. Os autores focalizam o tema visualizando a nutrição como um fator decisivo para um bom desenvolvimento social e econômico, particularizando o fato de que as intervenções nutricionais podem contribuir para melhorias significativas nos resultados escolares, na produtividade do trabalho e na resistência às infecções. Assim, os reflexos da desnutrição na economia seriam evidentes: quer pelas limitações na expectativa de renda, quer pelo aumento dos custos dos compromissos que a população assume para proteger-se, quer pelos avultados custos ocultos de origem social - absenteísmo, acidentes do trabalho e rotatividade de pessoal. Em face dos propósitos de modernização e competitividade da economia, é inquestionável a necessidade da nutrição figurar bem alto na lista de prioridades nacionais. Com isso, promover-se-ia o desenvolvimento dos recursos humanos e a preservação desse capital, que é o ideário de uma economia socialmente responsável.Discussions on development and nutrition frequently have a double focus: one that considers nutritional status as a reflection of development, and another that admits that nutrition strongly influences the level and rhythm of development. The authors view nutrition as a decisive factor for adequate social and economic development, specifying the fact that nutritional interventions might contribute to significant improvements in individual classroom performance, productivity at the workplace, and resistance to infections. The implications of malnutrition for the economy are thus evident: either by limitations in income expectations, increased costs deriving from burdens assumed by the population to protect themselves, or

  8. Desenvolvimento moral: considerações teóricas a partir de uma abordagem sociocultural construtivista

    Directory of Open Access Journals (Sweden)

    Martins Lincoln Coimbra

    2001-01-01

    Full Text Available Partindo da análise de trabalhos tradicionalmente realizados na área de desenvolvimento moral, o artigo sinaliza a necessidade de desenvolver uma abordagem teórica que trate o tema dentro de um enfoque que considere os aspectos socioculturais, cognitivos e afetivos. A questão central reside em abordar de forma sistêmica e integrada a dinâmica do desenvolvimento moral do indivíduo, resgatando a dimensão interativa e contextual envolvida na resolução dos conflitos morais e no desenvolvimento de crenças e valores. O trabalho parte dos pressupostos da perspectiva histórica socio-cultural construtivista do desenvolvimento humano, explicitando as exigências metodológicas implicadas na adoção dos conceitos e categorias utilizados no âmbito de tal perspectiva.

  9. Desenvolvimento moral: considerações teóricas a partir de uma abordagem sociocultural construtivista

    Directory of Open Access Journals (Sweden)

    Lincoln Coimbra Martins

    Full Text Available Partindo da análise de trabalhos tradicionalmente realizados na área de desenvolvimento moral, o artigo sinaliza a necessidade de desenvolver uma abordagem teórica que trate o tema dentro de um enfoque que considere os aspectos socioculturais, cognitivos e afetivos. A questão central reside em abordar de forma sistêmica e integrada a dinâmica do desenvolvimento moral do indivíduo, resgatando a dimensão interativa e contextual envolvida na resolução dos conflitos morais e no desenvolvimento de crenças e valores. O trabalho parte dos pressupostos da perspectiva histórica socio-cultural construtivista do desenvolvimento humano, explicitando as exigências metodológicas implicadas na adoção dos conceitos e categorias utilizados no âmbito de tal perspectiva.

  10. Preliminary results of the Programme to follow up radiological events in the federal district of Brasilia

    International Nuclear Information System (INIS)

    Correa, R.S.; Dias, C.M.; Nicoli, I.G.

    1998-01-01

    Since 1994, Brazil's Nuclear Energy Commission (CNEN) has been operating a telephone 'hotline' and pager service in the city of Brasilia which allows members of the public to report unusual situations involving radiation sources in the Federal District of Brasilia. One report was recorded in 1994, five in 1995 and 20 in 1996. Among the devices found in the Federal District following calls by concerned citizens were: a radioactive lightning rod, items of odontological and medical X ray equipment, smoke detectors, materials with radionuclides from research institutions and toxic materials. In the three-year period from 1994 to 1996, the radioactive lightning rod and odontological and medical X ray equipment represented seventy per cent of all the materials found. Until now, the Federal District has never experienced a real radiological emergency, as there has been no incidence of a loss of control of a radioactive source. By contrast, radiological events have occurred, and the difficulty they present is of a psychological nature, since the radioactive symbol found on the materials frightens the population. These facts show that emergency planning is necessary in the Federal District because the radiological events which occurred there in 1996 represented thirty-five per cent of all the events reported in the country. (author)

  11. Radiological protection in veterinary practice

    International Nuclear Information System (INIS)

    Konishi, Emiko; Tabara, Takashi; Kusama, Tomoko.

    1990-01-01

    To propose measures for radiological protection of veterinary workers in Japan, X-ray exposure of workers in typical conditions in veterinary clinics was assessed. Dose rates of useful beam and scattered radiation, worker exposure doses at different stations, and effectiveness of protective clothing were determined using TLD and ion chambers. As precausions against radiation, the following practices are important: (1) use of suitable and properly maintained X-ray equipment, (2) proper selection of safe working stations, (3) use of protective clothing. Regulations are necessary to restrict the use of X-rays in the veterinary field. Because the use of X-rays in the veterinary field is not currently controlled by law, the above precautions are essential for minimizing exposure of veterinary staff. (author)

  12. Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology

    OpenAIRE

    Pintaric, Robert; Matela, Joze; Pintaric, Stefan

    2015-01-01

    Background Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This pap...

  13. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong

    2017-01-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  14. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)

    2017-10-15

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  15. Performance of X-ray equipment used for conventional radiographic examinations of children

    International Nuclear Information System (INIS)

    Lacerda, Marco A.S.; Silva, Teogenes A. da; Khoury, Helen J.

    2009-01-01

    The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)

  16. Nevada Test Site Area 25, Radiological Survey and Cleanup Project, 1974-1983 (a revised final report). Revision 1

    International Nuclear Information System (INIS)

    Miller, M.G.

    1984-12-01

    This report describes the radiological survey, decontamination and decommissioning (D and D) of the Nevada Test Site (NTS) Area 25 facilities and land areas incorporated in the Nuclear Rocket Development Station (NRDS). Buildings, facilities and support systems used after 1959 for nuclear reactor and engine testing were surveyed for the presence of radioactive contamination. The radiological survey portion of the project encompassed portable instrument surveys and removable contamination surveys (swipe) for beta plus gamma and alpha radioactive contamination of facilities, equipment and land areas. Soil sampling was also accomplished. The majority of Area 25 facilities and land areas have been returned to unrestricted use. Remaining radiologically contaminated areas are posted with warning signs and barricades. 9 references, 23 figures

  17. Carolina Power and Light Company's computerized Radiological Information Management System

    International Nuclear Information System (INIS)

    Meyer, B.A.

    1987-01-01

    Carolina Power and Lignt Company has recently implement a new version of their computerized Radiological Information management System. The new version was programmed in-house and is run on the Company's mainframe computers. In addition to providing radiation worker dose histories and current dose updates, the system provides real-time access control for all three of the Company's nuclear plants such as respirator and survey equipment control and inventory, TLD QC records, and many other functions

  18. The quality assurance program data analysis for diagnostic radiology in government hospitals in southern provinces of Syria

    International Nuclear Information System (INIS)

    Kharita, M. H.; Khedr, M. S.; Wannus, K. M.

    2008-01-01

    This study covered comprehensive evaluation for diagnostic radiography and fluorography equipment used in medicine by applying SAEC quality control rules. The results showed that most of considered x-ray equipment have an acceptable performance but few reached 21.6% in radiography and 36.8% in fluorography need repair and recalibration. Also recommendations and guidance for repair and preventative maintenance are required and quality assurance program should be applied in all diagnostic radiology institutions in Syria.(author)

  19. Impact of ICRP 117 recommendations in the operational protection of vascular radiology unit

    International Nuclear Information System (INIS)

    Gomez, Pablo Luis; Fernandez, Manuel; Verde, Jose Maria; Perez, Maria Esperanza; Gomez, Nuria

    2013-01-01

    This paper lists and discusses the results obtained in the teams of the different specialties: traumatology, gastroenterology, hemodynamics, vascular radiology and neurosurgery at different care centres with various care portfolios and notable differences of technical resources. The results show a noticeable difference between the equipment used in gastroenterology, vascular radiology and hemodynamic reference services with other services and disciplines. Taking into account the recent 117 of ICRP publication it has been initiated a procedure for the estimation of dose of foot and ankle of the vascular radiologists and in crystalline. This paper shows the results obtained as well as the correlations between the mentioned area dose and values of dose of lapel, wrist, ankles and crystalline of the professionals

  20. Analysis of a quality assurance program in diagnostic radiology

    International Nuclear Information System (INIS)

    Goethlin, J.H.

    1986-01-01

    Retake analysis before and after introduction of a quality assurance program showed a 45% reduction of the retake rate. The most important changes concerning equipment and organizing of labour were: (1) More detailed inspection of development machines and X-ray generators, (2) new cassettes and intensifying screens, (3) reduction of the number of film formats used, (4) information and instruction of personnel. Cost reductions and profit from increased examination rate amounted to 4.5% of the overall operating costs of the radiologic department. (author)

  1. Abordagem grassroots e resistência: atualizando a concepção de desenvolvimento sustentável

    Directory of Open Access Journals (Sweden)

    Augusto Marcos Carvalho de Sena

    Full Text Available Resumo Em contrapartida às especificidades impositivas do modelo de produção capitalista - incluindo-se nesse modelo os meandros de arranjos produtivos que inserem o meio ambiente enquanto alinhado à versão tríplice da concepção tradicional de desenvolvimento sustentável -, tem surgido uma massa crítica de literatura focada na resistência ao modo de funcionamento do capitalismo ocidental. Em relação à teoria, economia solidária (pilar econômico, movimentos sociais (pilar social, ecologia política (pilar ambiental e raízes culturais (pilar cultural são aparatos importantes que não devem ficar à margem na estruturação de uma concepção alternativa do desenvolvimento sustentável. Tais aparatos são considerados elementos de resistência, visto terem fatores diferenciados quando comparados com as características tradicionais dos pilares da criticada concepção de desenvolvimento sustentável. Assim, o objetivo do presente ensaio teórico é conceber alternativas à concepção padrão do desenvolvimento sustentável, considerando aspectos da abordagem grassroots importantes para esse propósito. A contribuição é relevante tendo em vista a consideração de aspectos alternativos e complementares envolvidos na leitura da atualização conjecturada. Os prospectos do desenvolvimento grassroots têm sido usados como guia prático em ações de desenvolvimento local envolvendo comunidades menos desenvolvidas em várias partes do mundo, sem a conjectura que sinaliza para elementos conceituais que podem oferecer uma conformação alternativa à concepção do desenvolvimento sustentável. Conclui-se que a versão tradicional do desenvolvimento sustentável pode ser atualizada com elementos alternativos advindos da abordagem grassroots.

  2. Radiological protection report 2016

    International Nuclear Information System (INIS)

    2017-06-01

    on the basis of international recommendations. ENSI uses inspections and comparative measurements to ensure that the necessary calibrated radiological protection measurement equipment is available and that it is used for its intended purpose in order to determine correct values. For this purpose, it operates a test centre accredited to ISO 17025. The network operated by ENSI for automatically monitoring the dose rate in the vicinity of nuclear power plants measures dose rates in the vicinity of nuclear power stations all year round and 24 hours a day. The 10-minute, hourly and daily mean rates measured can be viewed on ENSI's web site in real time. This monitoring network serves to secure evidence for the authorities and in dealings with the public. No local increases in dose rates that could be attributed to discharges from nuclear power plants were detected in the reporting year. Sporadic, locally high measurements are due to fluctuations in natural background radiation, e.g. after rainfall. The programme JRODOS (Java-based Realtime Online DecisiOn Support system) has been used since the beginning of 2016 to model atmospheric spread and calculate the dose, should an event occur. JRODOS allows the direct use of 3D weather forecast data from the COSMO-1 model routinely used by MeteoSwiss with a grid size of 1 km. The COSMO-1 model supplies forecasts stretching up to 24 hours into the future with high spatial and temporal resolution. In order to reflect the small scale structure of the Swiss countryside and that of southern Germany, JRODOS uses the very high resolution elevation model from the Swiss Federal Office of Topography. This means that together with the aerial radiometric equipment, there are invaluable, precise instruments available at all times for making current assessments (diagnoses) as well as forecasts of the radiological situation. In the reporting year, all thresholds contained in the Federal Ordinance on radiation protection were met. There

  3. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment; Desenvolvimento de um dispositivo artesanal para os testes de colimação e alinhamento do raio central em equipamentos médicos de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S., E-mail: elizabethberbr@live.com [Universidade José de Souza Herdy (UNINGRANRIO), Nova Iguaçu, RJ (Brazil)

    2017-07-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden.

  4. Modern radiology in oncology and waiting lists for procedures: Breast cancer screening in Slovenia

    Directory of Open Access Journals (Sweden)

    Maksimiljan Kadivec

    2007-12-01

    Full Text Available Background: Good and modern radiology equipment is needed for successful treatment of the oncologic patients. New Department of Radiology of the Institute of Oncology Ljubljana is entirely digital and can compete with the similar radiologic departments all over the world. It si possible to perform all the new modern procedures that the oncologic patients need. Important diagnostic modality is PET CT that fulfill the selection of the diagnostic procedures for cancer patients. The problem of Slovenian radiology is lack of the radiologists. This problem could be solved with telemedicine and properly awarded work that was performed. Waiting lists for procedures like CT, MR, US are short for oncologic patients in comparison with the other radiologic units in Slovenia.Conclusions: At the beginning of the year 2008 we will start the Breast Cancer Screening Program in Slovenia. It is organized by Institute of Oncology Ljubljana (DORA program. Breast cancer screening program will be centralized, in accordance with of the European guidelines for quality assurance in breast cancer screening and diagnosis 2006 (fourth edition and supervision of reference breast screening center. The main goal of the breast cancer screening program in Slovenia is reduction of the breast cancer death for 25 % or more.

  5. General Employee Radiological Training and Radiological Worker Training: Program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE General Employee Radiological Training (GERT) and Radiological Worker I and II (RW I and II) Training programs. It includes material development requirements, standards and policies, and program administration. This manual applies to General Employee Radiological Training and Radiological Worker Training at all DOE contractor sites. The training materials of both GERT and RW I and II training reflect the requirements identified in the DOE Radiological Control Manual and DOE Order 5480.11. The training programs represent the minimum requirement for the standardized core materials. Each contractor shall implement the program in its entirety and may augment the standardized core materials to increase the general employee and radiological worker level of competency

  6. Radiological characterisation on V1 NPP technological systems and buildings - Contamination

    International Nuclear Information System (INIS)

    Hanzel, Richard; Rapant, Tibor; Svitek, Jaroslav

    2012-01-01

    : average dose rate, maximum dose rate, average surface contamination of floor and walls and possible identified higher local surface contamination. In the scope of the project, more than 3400 direct dose rates measurements, 1450 direct surface contamination measurements, 1200 laboratory alpha/beta/gamma analysis of outer surfaces, 560 sample analysis of primary circuit technological equipment inner surface, 20 in situ gamma spectrometric measurements and 15 sample analysis of concrete drilling cores, have been performed. Final list of RNV included 8 vectors for contamination. Radiological data of individual items in DDB have been used for determination of total radiological inventory of V1 NPP. (authors)

  7. Technical basis and radiological release plan for Trackhoes used at 100 BC-1 and 100 DR-1

    International Nuclear Information System (INIS)

    De Mers, S.K.

    1997-06-01

    To develop a method for the radiological release of tracked heavy equipment vehicles used in the excavation of the 100-BC-1 and 100-DR remedial action sites, including the technical basis for selection of release criteria and the instrumentation to be used for surveys

  8. Radiological diagnosis in traumatology; Radiologische Diagnostik in der Traumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Frahm, R. (ed.)

    2001-07-01

    This loose-leaf publication covers all radiological problems that may possibly occur in accident surgery. The focus is on conventional radiological diagnosis. The physical and technical fundamentals of diagnostic examination methods are discussed, followed by practical hints on radiation protection, technical equipment and quality assurance, as well as accurate information on the procedure of taking and interpreting standard X-ray pictures. The indications for standard X-raying, tomography, CT and MRT are presented in consideration of the radiation exposure incurred by the patient. The reader is also informed on the dynamics and varying morphology of bone fracture healing, potential disturbances of callus formation and reconstruction, as well as on possible complications. The main section of the book discusses injuries of the skull, spinal cord, pectoral girdle, upper arm, elbow and lower arm, wrist and hands, pelvis, hip joint, knee and upper and lower leg, ankle joint and foot, thorax and abdomen. (orig.)

  9. Vigilância do desenvolvimento da linguagem da criança: conhecimentos e práticas de profissionais da atenção básica à saúde

    Directory of Open Access Journals (Sweden)

    Raquel Aparecida Pizolato

    Full Text Available RESUMO Objetivo: analisar os conhecimentos e as práticas dos enfermeiros, médicos e cirurgiões-dentistas que atuam na Atenção Básica em relação ao desenvolvimento da linguagem da criança nos primeiros anos de vida. Métodos: tratou-se de uma pesquisa qualitativa com 30 profissionais de uma rede de Atenção Básica dentre eles, médicos, enfermeiros e cirurgiões-dentistas. Uma consulta individual foi realizada mediante um questionário semiestruturado. Empregou-se a técnica de análise temática de discurso, utilizando-se três figuras metodológicas: a Ideia Central, as Expressões-Chaves e o Discurso do Sujeito Coletivo. Resultados: os conhecimentos que os profissionais têm sobre o desenvolvimento da linguagem da criança estavam ancorados às ideias centrais de conhecer alguns marcos do desenvolvimento, a linguagem da criança depende do estímulo do meio, da família e da audição normal, saber muito pouco ou não saber nada sobre o assunto. Os profissionais relataram que gostariam de obter mais informações sobre o assunto em relação aos marcos do desenvolvimento da linguagem da criança, desvios da normalidade e orientações para pais de forma a aprimorar o atendimento da saúde infantil. Conclusão: o conhecimento dos profissionais sobre o assunto apresentou-se limitado, havendo necessidade de ampliar práticas de educação em saúde pela Fonoaudiologia, em parceria com as Instituições de Ensino e os profissionais dos Núcleos de Apoio Saúde da Família, junto aos profissionais da Equipe de Estratégia Saúde da Família, destacando-se o trabalho sobre os marcos do desenvolvimento da linguagem da criança.

  10. Radiological assessment of radioactive contamination on private clothing

    International Nuclear Information System (INIS)

    Schartmann, F.; Thierfeldt, S.

    2003-01-01

    In the very rare, cases where private clothing of persons working in a nuclear installation are inadvertently contaminated and this contamination is not detected when leaving the facility, there may be radiological consequences for this person as well as for members of his or her family. The VGB (Technische Vereinigung der Grosskraftwerksbetreiber) in Germany has investigated in detail the spread of contamination in nuclear power plants. Part of this evaluation programme was a radiological analysis which has been carried out by Brenk Systemplanung GmbH (Aachen/Germany). The radiological analysis started with the definition of the source term. It is highly unlikely that activities of more than 5 kBq 60 Co could leave a plant undetected on the body or the clothes. Nevertheless activities up to 50 kBq and different nuclide vectors were regarded. It has been found that 60 Co is the most important contaminant. The radiological analysis focusses on two types of contamination: particles and surface contamination. The pathways by which such a contamination can lead to an exposure by external irradiation or by ingestion depend on the type of contamination and are analysed in detail. For example, a particle could be retained in pockets or other parts of clothing and may lead to prolonged external irradiation until the piece of clothing is washed. The analysis is performed on the basis of conservative to realistic assumptions. In conclusion, the analysis has shown that especially particle contamination needs to be focussed on. However, by the advanced detection equipment in German plants doses which may pose a health hazard can safely be excluded. (authors)

  11. Anatomist and the pioneer of radiology Étienne Destot--95th anniversary of his death.

    Science.gov (United States)

    Báča, Václav; Kachlík, David; Báčová, Tereza; Bartoška, Radek; Marvan, Jiří; Douša, Pavel; Secrest, Thomas; Džupa, Valér

    2014-04-01

    Destot was a leading pioneer in radiology, a pupil of Ollier, an anatomist, and researcher who followed in the experimental medicine tradition of Claude Bérnard. This work is an extensive, in depth, look at the life and work of Étienne Destot. On February 5, 1896, he began performing X-ray examinations, less than two months after Roentgen's discovery! His pioneering work described a space bordered by the hamate, capitate, triquetrum, and lunate; this space is now known as Destot's space. Tanton stated that Destot was the first to reveal the mechanism of fractures of the posterior margin of the distal tibia and to emphasize their clinical relevance; in honor of this contribution, Tanton named such a fracture the “fracture of Destot.” Moreover, Destot is credited with being the first physician to use the term “pilon” in the orthopedic literature. He first described fractures of the scaphoid in 1905. He also described superficial hematomas, Destot's sign, located above the inguinal ligament or in the scrotum or thigh. Such hematomas are indicative of pelvic fractures. Destot is credited with inventing or improving many pieces of medical equipment (e.g., Lambotte's screw plates, anastomotic boutons for the digestive tube, monopolar endocavital radiological tubes). He was also active in developing technical aspects of equipment (e.g., radioscopic examination of the heart, a prototype of the mobile radiological laboratory). Étienne Destot is best known as a radiologist; however, his influence extends well beyond this field. He was an anatomist and surgeon, the founder of radiology in Lyon, prosector, physician, electrician, researcher, and artist.

  12. Rassyn: National radiological safety data management system

    International Nuclear Information System (INIS)

    Domenech Nieves, Haydee; Valdez Ramso, Maryzury; Jova Sed, Luis; De la Fuente, Andres

    1996-01-01

    The paper describes the menu, screens data files, programs and classifications of the systems, for keeping a record of their institutions, inspection and authorization, the personal register of incidents and accidents, and the national inventory of radiation protection sources and equipment. By making use of it, a comparison can be made of existing data of a practice with its requirements and a questionnaire of the inspection, (Checking list), the development and results of the inspection can be reported on, the program and notification of the inspection can be prepared and the information on the radiological situation- whether at a national or at a territorial level- can be evaluated

  13. The radiological protection in the practice of industrial X-rays

    International Nuclear Information System (INIS)

    Jimenez C, I.; Carrasco C, R.

    2010-09-01

    The kindness of this technique of non destructive assays is very appreciative when the protection standards and radiological protection are completed faithfully, this work show in a succinct way the development through the years where have improved the equipment s, the procedures, the training and the regulation. This development has allowed reduce the dose to the occupational exposed personnel, to the public, but mainly the accidents incidence with loss of fingers, hands, legs and worker lives, children and the people in general. (Author)

  14. Nacionalismo e desenvolvimento

    Directory of Open Access Journals (Sweden)

    Paulo Nogueira Batista Jr.

    2007-03-01

    Full Text Available Este texto discute o nacionalismo, tomando emprestadas algumas proposições de um filósofo declarada e radicalmente antinacionalista, Friedrich Nietzsche. Procura-se argumentar que, ressalvados os raros casos de integração regional profunda, o nacionalismo é, na prática, o único caminho para o desenvolvimento econômico e a melhoria das condições de vida das populações na periferia da economia internacional.This paper discusses nationalism, borrowing some propositions from a philosopher who was openly and radically antinationalist, Friedrich Nietzsche. It argues that, with the exception of the rare cases of deep regional integration, nationalism is, in practice, the only route to economic development and the improvement of the standards of living of populations in the periphery of the international economy.

  15. Specialized consultant in radiological safety to the north central hospital of high speciality, PEMEX. III. - September of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-12-01

    The north central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  16. Specialized consultant in radiological safety to the north central hospital of high speciality, PEMEX. II. - August of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-10-01

    The north central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  17. Specialized consultant in radiological safety to the north central hospital of high speciality, PEMEX. I. - July of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.

    2001-09-01

    The north central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  18. Specialized consultant in radiological safety to the south central hospital of high speciality, PEMEX. II.- August of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-12-01

    The south central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  19. Specialized consultant in radiological safety to the south central hospital of high speciality, PEMEX. III.- September of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Rodriguez A, F.; Garcia A, J.

    2001-12-01

    The south central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  20. Specialized consultant in radiological safety to the south central hospital of high speciality, PEMEX. IV. - October of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The south central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  1. Specialized consultant in radiological safety to the south central hospital of high speciality, PEMEX. I. - July of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.

    2001-09-01

    The south central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  2. Specialized consultant in radiological safety to the south central hospital of high speciality, PEMEX. V. - November of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The south central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  3. UY 100 standard basic regulation of protection and radiological safety: approve by Industry Energy and Mining Ministry 28/6/2002 Resolution

    International Nuclear Information System (INIS)

    2002-01-01

    The following standard studies basic purposes of the radiological protection,practices classification, required for authorization in nuclear installations, equipment and radiation sources to grant permission, occupational, medical, and public exposition, and emergency plans

  4. Current status and future direction of radiology in the Philippines

    International Nuclear Information System (INIS)

    Villacorta, E.V.

    1988-01-01

    The author reported that there is a favourable increase of X-ray machine and radiologists proportionate to the increase of population in the Philippines but these are concentrated in Metro Manila. There is a proliferation of ultrasound units because of the cheaper cost of machines and lower overhead of the non-invasive and radiation-free procedure. It is noted that only four radiologists are actively involved in nuclear medicine. Facilities of radiotherapy and the number of radiation oncologists have remained stagnant for the past eight years; many of the equipment are poorly maintained and cobalt-60 sources unreplenished. Another drawback is the public fear of radiation from ionizing radiation emitting modalities such as diagnostic X-ray, nuclear medicine and computed tomography. Likewise, the future of radiology in the Philippines lies in the state of the art radiological facilities not yet available in the country. (ELC). 8 refs.; 9 tabs

  5. Proposed procedure and analysis of results to verify the indicator of the product dose-area in radiology equipment

    International Nuclear Information System (INIS)

    Garcia Marcos, R.; Gallego Franco, P.; Sierra Diaz, F.; Gonzalez Ruiz, C.; Rodriguez Checa, M.; Brasa Estevez, M.; Gomez Calvar, R.

    2013-01-01

    The aim of this work is to establish a procedure to verify the value of the product dose-area showing certain teams of Radiology, with an alternative to the use of external transmission cameras. (Author)

  6. Overview of the use and radiological protection of body scanner equipment in Brazil

    International Nuclear Information System (INIS)

    Souza, D.A.P.; Nascimento, C.S.; Silva, F.C.A. da

    2017-01-01

    After security incidents in recent years, there is a growing need for security at airports, ports and prisons. In the fight against terrorism, smuggling and illegal entry of material, X-rays are used for non-invasive inspection of people. Traditionally, surveillance has been done exclusively on people by metal detection techniques or by intimate search. But in today's globalized world, and given concern for international security, governments are considering introducing a new series of technologies at airports and prisons, which reveal what an individual can carry under their clothes when traveling or entering visitation in prisons. Body inspection equipment, also called body scanners or 'body scanner', which can detect metallic and non-metallic objects hidden in a person's body, such as weapons, drugs, precious stones, cell phones, etc. This work shows the types of body inspection equipment, the radiation doses involved, and the radiation protection aspects that are critical to maintaining the safety of all users

  7. Student Perceptions of Educational Quality in Radiologic Technology Programs: A Comparative Analysis of Specialized and Institutional Accreditation

    Science.gov (United States)

    Vander Hoek, Nancy

    2012-01-01

    The purpose of this study was to determine if students' perceptions of quality differed between Joint Review Committee on Education in Radiologic Technology (JRCERT) accredited and non JRCERT-accredited radiography programs using the quality dimensions of curriculum, faculty, facilities and equipment, integrity, student outcomes, and overall…

  8. Doses to patients from dental radiology in France

    International Nuclear Information System (INIS)

    Benedittini, M.; Maccia, C.; Lefaure, C.; Fagnani, F.

    1989-01-01

    In France, a national study was undertaken to estimate both dental radiology practices (equipment and activity) and the associated population collective dose. This study was done in two steps: A nationwide survey was conducted on the practitioner categories involved in dental radiology, and dosimetric measurements were performed on patients and on an anthropomorphic phantom by using conventional dental x-ray machines and pantomographic units. A total of 27.5 x 10(6) films were estimated to have been performed in 1984; 6% of them were pantomographic and 94% were conventional. Most of the organ doses measured for one intra-oral film were lower than 1 mGy (100 mrad); pantomogram dose values were generally higher than intra-oral ones. The collective effective dose equivalent figure was 2,000 person-Sv (2 x 10(5) person rem) leading to a per head dose equivalent of 0.037 mSv (3.7 mrem). The study allowed authors to identify ways to reduce the patient dose in France (e.g., implementing the use of long cone devices and controlling darkroom practices)

  9. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  10. Spanish Radiology in the second half of the XX Century: A view from inside

    International Nuclear Information System (INIS)

    Bonmati, Jose

    2008-01-01

    Radiology was born in 1896 with the immediate recognition of the diagnostic value of X-rays in medicine and progressed throughout the XX Century with the increasing knowledge of its properties and clinical applications. By mid-century Radiology was a respected clinical specialty in advanced countries, the radiological report was a requirement in hospital practice and radiologists' opinions requested in scientific meetings. In the last decades of the century has had a spectacular expansion with the emergence of new imaging modalities and revolutionary technologies that have transformed the specialty worldwide. In Spain Radiology lagged behind needs and demand in 1950. Radiological practice was unregulated and performance of X-ray exams by non-radiologists was common. Teaching of Radiology was non-existent in Medical Schools or postgraduation. The diagnostic value of the specialty was unrecognized by physicians and the role of radiologists ignored. Most hospital radiology services were poorly equipped and functionally inadequate. The shadow of the Civil War (1936-39) was conditioning Radiology in the country. The point of inflexion in the development of Radiology in Spain was the inclusion of film reading sessions in the 1965 academic program of the Society of Radiology. It was in the presentation of cases at these conferences that Clinical Radiology found the finest demonstration ground and as a result was immediately adopted by radiologists and progressively applied in scientific meetings, clinical practices and training programs. Its influence was important in reforming hospital practice, legislation on specialization and education, as well as in national health care plans. At the end of the century radiology in Spain was at a par with the standards of other western nations. The author was a witness of the evolution of Radiology during his 50 years of professional life. This article does not pretend to be exhaustive in names or contributions. It is an overview of

  11. Saúde e desenvolvimento Healthcare and development

    Directory of Open Access Journals (Sweden)

    Ana Luiza D'Ávila Viana

    2007-11-01

    Full Text Available Considerando que os modernos sistemas de saúde são o resultado da complexa interação de processos econômicos, políticos e sociais, o objetivo do trabalho é discutir a relação entre saúde e desenvolvimento no Brasil, mostrando que o esgotamento do modelo liberal de política econômica abre nova perspectiva para a retomada do desenvolvimento, entendido como combinação entre crescimento da economia, mudanças na estrutura produtiva e melhora das condições de vida da população. O complexo produtivo da saúde joga papel decisivo nesse processo, pois constitui um campo em que inovação tecnológica e acumulação de capital geram oportunidades de investimento, trabalho e renda, além de produzir avanços importantes para melhorar o estado de saúde das pessoas. A recente adoção de políticas públicas voltadas para articular, de forma positiva, aspectos da política econômica e da política social revela que a questão do desenvolvimento nacional ganhou nova centralidade na agenda governamental, o que abre a perspectiva de maior integração entre a lógica econômica e a lógica sanitária. Entretanto, é preciso reconhecer que o Brasil ainda não logrou alcançar uma associação virtuosa entre saúde e desenvolvimento.As modern healthcare systems are the outcome of complex interactions among economic, political and social processes, the purpose of this paper is to discuss the links between health and development in Brazil, showing that the depletion of the liberal economic policy model paves the way for a return to development, understood as a blend of economic growth, changes in the production structure and better living standards. The healthcare production complex plays a crucial role in this process, as a field where technological innovation and capital build-up generate opportunities for investment, work and income, in addition to spurring major steps forward in terms of upgrading individual health. The recent adoption of

  12. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  13. Radiology and fine art.

    Science.gov (United States)

    Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver

    2012-07-01

    The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.

  14. Experience in industrial radiography equipment into carry out inspections in Brazil

    International Nuclear Information System (INIS)

    Lopes, Valdir Maciel; Silva, Joao

    2008-01-01

    The Nuclear and Energy Research Institute (IPEN), in accordance with the attributions given by the National Commission of Nuclear Energy (CNEN), has been supplying the market with radioactive sealed sources of Iridium 192 ( 192 Ir), for Brazil and some South America Countries, for more than 24 years. In this period, the experience acquired in the accompanied of the technological improvement in the industrial gammagraphy equipment; into Sealed Sources Production Laboratory (LPFS) will be show. Of the set of operations carry out in the LPFS, since the assemblies, tests of qualification of the sources also inspection at of the equipment for posterior applications in field, it is intended to demonstrate to the technological improvement associate to the radiological and operational security. In this work, the data base of the system of the LPFS will be used, as well as the professional experience of the laboratory team in the daily relationship with the companies responsible for the equipment operation. (author)

  15. Radiology and the mobile device: Radiology in motion

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2012-01-01

    Full Text Available The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available.

  16. Radiology and the mobile device: Radiology in motion

    International Nuclear Information System (INIS)

    Panughpath, Sridhar G; Kalyanpur, Arjun

    2012-01-01

    The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available

  17. Comparison of time-oriented cost accounting catalogs to control a Departement of Radiology

    International Nuclear Information System (INIS)

    Hacklaender, T.; Mertens, H.; Cramer, B.M.

    2005-01-01

    Purpose: Within a hospital, the radiology department has taken over the role of a cost center. Cost accounting can be applied to analyze the cost for the performance of services. By assigning the expenditures of resources to the service, the cash value can directly be distributed to the costs of equipment, material and rooms. Time-oriented catalogs of services are predefined to calculate the number of the employees for a radiology department. Using our own survey of time data, we examined whether such catalogs correctly represent the time consumed in a radiology department. Only services relevant for the turnover were compared. Materials and Methods: For 96 primary radiological services defined by the score-oriented German fee catalog for physicians (Gebuehrenordnung fuer Aerzte), a ranking list was made for the annual procedures in descending frequency order. According to the Pareto principle, the 11 services with the highest frequency were chosen and the time consumed for the technical and medical services was collected over a period of 2 months. This survey was compared with the time-oriented catalogs TARMED and EBM 2000plus. Results: The included 11 relevant radiological services represented 80.3% of the annual procedures of our radiology department. When comparing the technical services between the time-oriented catalogs and our own survey, TARMED gives a better description of the time consumed in 7 of the 11 services and EMB 2000plus in 3 services. When comparing the medical services, TARMED gives a better description of the time consumed in 6 of the 11 services and EBM 2000plus in 4 services. When averaging all the radiological services, TARMED overestimates the current number of physicians necessary for primary reading by a factor of 10.0% and EBM 2000plus by a factor of 2.6%. Conclusion: As to the time spent on performing the relevant radiological services. TARMED is slightly superior to describe the radiology department of a hospital than EBM 2000plus

  18. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    International Nuclear Information System (INIS)

    Kim, Seon Chil

    2008-01-01

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  19. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Chil [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of)

    2008-12-15

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  20. Biopolítica e Desenvolvimento? Foucault e Agamben sobre Estado, Governo e Violência

    Directory of Open Access Journals (Sweden)

    Guilherme F. W. Radomsky

    2015-06-01

    Full Text Available Este artigo analisa as relações entre biopolítica e desenvolvimento sob o ângulo das noções de Estado, governo e violência. O objetivo consiste em examinar elementos analíticos que gravitam em torno de perspectivas críticas do desenvolvimento buscando um eixo interpretativo sobre a ambivalência das ações do Estado a partir de duas possibilidades teóricas que convergem no pensamento de Giorgio Agamben: a análise do biopoder e do governo em Foucault e as articulações entre violência e lei que remetem a Walter Benjamin. A reflexão sobre os argumentos teóricos é realizada examinando-se dados oriundos de pesquisa de abordagem qualitativa sobre políticas para a agricultura ecológica no sul do Brasil. As conclusões mostram que o desenvolvimento e seus benefícios podem ser problematizados pelo olhar do biopoder e da violência, que reconfiguram o que seja desenvolvimento, menos como expansão do bem-estar e mais como impulso modernizante de mudança que se ampara em administrar a vida.

  1. Clinical dosimetry in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Jovanovska, A.

    2012-01-01

    Full text: Introduction: Diagnostic and interventional procedures involving x-rays are the most significant contributor to total population dose form man made sources of ionizing radiation. Purpose and aim: X-ray imaging generally covers a diverse range of examination types, many of which are increasing in frequency and technical complexity. Materials and methods: The European Directives 96/29 and 97/43 EURATOM stress the importance of accurate dosimetry and require calibration of all measuring equipment related to application of ionizing radiation in medicine. Results: The paper gives and overview of current system of dosimetry of ionizing radiations that is relevant for metrology and clinical applications. It also reflects recently achieved international harmonization in the field promoted by International Atomic Energy Agency (IAEA). Discussion: Objectives of clinical dose measurements in diagnostic and interventional radiology are multiple, as assessment of equipment performance, or assessment of risk emerging from use of ionizing radiation Conclusion: Therefore, from the clinical point of view, the requirements for dosimeters and procedures to assess dose to standard dosimetry phantoms and patients in clinical diverse modalities, as computed tomography are presented

  2. Estudo longitudinal do desenvolvimento da comunicação em diversas economias mundiais.

    Directory of Open Access Journals (Sweden)

    Emílio José Montero Arruda Filho

    2012-08-01

    Full Text Available O desenvolvimento do setor de comunicação de um país possui relações com o seu desenvolvimento econômico e é possível demonstrar essa conexão estatisticamente, como tem sido feito por pesquisadores de instituições como a ITU (International Telecommunications Union. Como esses dados estão apenas apresentados na forma simples e não levam em conta fatores de interconexão, é importante desenvolver pesquisas que avaliem a conexão entre variáveis relevantes no campo. Este trabalho visa analisar os fatores de desenvolvimento tecnológico de comunicação que melhor descrevem o posicionamento econômico de um país, integrando a usabilidade dos serviços de comunicação com o status econômico. Foram utilizados dados de 56 países, escolhidos aleatoriamente. Uma pesquisa na forma de datamining foi realizada, a qual analisou os dados existentes já previamente coletados por instituições de pesquisa tais como ITU, World Bank, e outras. Cada fator de usabilidade, preferência e serviço analisado é apontado como um reflexo de outros serviços e usos anteriormente desenvolvidos. Parte da literatura sobre esse tópico (ARRUDA FILHO; CASSIA; MARINO, 2008; CHERRY, 2007; DAVIES; HARDT; KELLY, 2004 argument que o desenvolvimento econômico de certos países existe como resultado de um aumento do desenvolvimento tecnológico, porém outras demonstram ou informam o contrário. Este artigo apresenta essas relações em certos países, escolhidos pela quantidade de informação disponível considerando sua posição de desenvolvimento global, relacionando diretamente o comportamento de crescimento ou redução no uso das tecnologias, tais como telefone e internet. Este trabalho coletou dados de duas fontes mundiais de informação dos setores mencionados: a International Telecommunications Union (ITU e o World Bank. Utilizaram-se as técnicas estatísticas de regressão e análise de variância para a análise de dados de 56 países ao longo de

  3. Calibration of instrument and personnel monitoring in radiological protection

    International Nuclear Information System (INIS)

    Abdul Aziz Mohamad Ramli; Wan Saffiey Wan Abdullah

    1987-01-01

    It is difficult to choose radioprotection equipments that are not too expensive and suit the purpose. Some of the dosimetric characteristics of good dosemeters outlined by ISO 4071-1978 (E) namely scale linearity, energy dependence, radiation quality dependence and angular dependence for some of the commercially available dosemeters are discussed. The calibration procedures practised at the National Secondary Standard Dosimetry Laboratory (SSDL), of the Nuclear Energy Unit (NEU) is also explained. The radiological equipments for personnel monitoring such as film badge and TLD are widely used to estimate the radiation dose delivered to the whole or partial body of a personnel. Both of the personnel monitoring procedures have been established at the NEU. The objective, use and maintenance of the devices are also discussed in detail. The evaluation of the monthly dose received by a personnel from various establishments in the country are also presented. (author). 17 figs

  4. Portrayal of radiology in a major medical television series: How does it influence the perception of radiology among patients and radiology professionals?

    International Nuclear Information System (INIS)

    Heye, T.; Merkle, E.M.; Boll, D.T.; Leyendecker, J.R.; Gupta, R.T.

    2016-01-01

    To assess how the portrayal of Radiology on medical TV shows is perceived by patients and radiology professionals. In this IRB-approved study with patient consent waived, surveys were conducted among adult patients scheduled for radiological examinations and radiology professionals. The questionnaire investigated medical TV watching habits including interest in medical TV shows, appearance of radiological examination/staff, radiology's role in diagnosis-making, and rating of the shows' accuracy in portraying radiology relative to reality. One hundred and twenty-six patients and 240 professionals (133 technologists, 107 radiologists) participated. 63.5 % patients and 63.2 % technologists rated interest in medical TV shows ≥5 (scale 1-10) versus 38.3 % of radiologists. All groups noted regular (every 2nd/3rd show) to >1/show appearance of radiological examinations in 58.5-88.2 % compared to 21.0-46.2 % for radiological staff appearance. Radiology played a role in diagnosis-making regularly to >1/show in 45.3-52.6 %. There is a positive correlation for interest in medical TV and the perception that radiology is accurately portrayed for patients (r = 0.49; P = 0.001) and technologists (r = 0.38; P = 0.001) but not for radiologists (r = 0.01). The majority of patients perceive the portrayed content as accurate. Radiologists should be aware of this cultivation effect to understand their patients' behaviour which may create false expectations towards radiological examinations and potential safety hazards. (orig.)

  5. UM ESTUDO DA RELAÇÃO ENTRE O TRABALHO EM EQUIPE E A APRENDIZAGEM ORGANIZACIONAL

    Directory of Open Access Journals (Sweden)

    Julia Hosana Santos Franco

    2011-06-01

    Full Text Available O artigo apresenta os resultados de pesquisa realizada acerca do trabalho em equipe e aprendizagem organizacional. Na pesquisa, o objetivo geral foi o de analisar as estratégias utilizadas pela gestão com pessoas para incentivar o trabalho em equipe, visando alcançar êxito no processo de aprendizagem no contexto organizacional. O artigo busca responder ao seguinte problema: quais estratégias são utilizadas pela gestão com pessoas para incentivar o trabalho em equipe visando êxito na aprendizagem organizacional? Para o desenvolvimento da pesquisa, recorreu-se ao estudo do caso da empresa BETA S/A, do setor siderúrgico, que resolveu implantar o trabalho em equipe. Nesse sentido, houve a oportunidade de pesquisarmos os desdobramento da prática e suas decorrências sob a ótica dos empregados das diversas áreas. Dentro do estudo foram realizadas 39 entrevistas com líderes e subordinados. Quanto aos resultados, inicialmente, verificou-se que apesar da literatura defender um perfil inovador e estratégico para a área de RH, considerando suas transformações para a valorização do profissional como alternativa para alcançar melhores resultados organizacionais, identificamos que a prática do trabalho em equipe carece de aprofundamento no estudo de suas iniciativas e conseqüências, sendo inclusive de difícil aplicação em qualquer organização.

  6. TECNOLOGIAS DIGITAIS: PROMOVENDO O DESENVOLVIMENTO SUSTENTÁVEL PARA O JOVEM DO CAMPO

    OpenAIRE

    Zarpelon, Mirian Cátia; Kolcenti, Cassiane; Balestrin, Deisi; Tortelli, Luana; Blazszack, Vinicíus; Guedes, Anibal Lopes

    2015-01-01

    O desenvolvimento sustentável é hoje em dia, um dos principais desafios a ser enfrentado na atualidade. Inclui-se neste universo a agricultura, através da consolidação das atividades produtivas a fim de desenvolver de forma sustentável, a gestão da propriedade rural, bem como sua condição ambiental e social, sem degradar o capital natural e mantendo o bem estar da sociedade. Dentro desse processo, as novas tecnologias proporcionam o desenvolvimento de soluções criativas simples que visam melh...

  7. Economia e Desenvolvimento Social: A Possibilidade da Utilização de Indicadores Sociais na Avaliação do Desenvolvimento Paranaense

    Directory of Open Access Journals (Sweden)

    Daniel Vitor Vicente

    2013-12-01

    Full Text Available Este trabalho pretende analisar a progressão de indicadores sociais no Paraná a partir dos anos 1990, utilizando como base de dados os indicadores sociais de Educação, Emprego e Renda, Saúde e Saneamento, disponibilizados pelo Instituto Paranaense de Desenvolvimento Econômico e Social - IPARDES. Para o desdobramento de tal reflexão, será resgatado brevemente o desenvolvimento econômico Brasileiro, cujo projeto de Estado está embasado no que se conhece por novo desenvolvimentismo. Do mesmo modo, também será abordada a possibilidade de serem utilizados indicadores sociais públicos e gratuitos, a fim de que os mesmos auxiliem nos procedimentos de análise e problematização de questões sociais que interessam às Ciências Sociais, utilizando-se como exemplo os dados que serão apresentados.

  8. Picture archiving and communication in radiology.

    Science.gov (United States)

    Napoli, Marzia; Nanni, Marinella; Cimarra, Stefania; Crisafulli, Letizia; Campioni, Paolo; Marano, Pasquale

    2003-01-01

    After over 80 years of exclusive archiving of radiologic films, at present, in Radiology, digital archiving is increasingly gaining ground. Digital archiving allows a considerable reduction in costs and space saving, but most importantly, immediate or remote consultation of all examinations and reports in the hospital clinical wards, is feasible. The RIS system, in this case, is the starting point of the process of electronic archiving which however is the task of PACS. The latter can be used as radiologic archive in accordance with the law provided that it is in conformance with some specifications as the use of optical long-term storage media or with electronic track of change. PACS archives, in a hierarchical system, all digital images produced by each diagnostic imaging modality. Images and patient data can be retrieved and used for consultation or remote consultation by the reporting radiologist who requires images and reports of previous radiologic examinations or by the referring physician of the ward. Modern PACS owing to the WEB server allow remote access to extremely simplified images and data however ensuring the due regulations and access protections. Since the PACS enables a simpler data communication within the hospital, security and patient privacy should be protected. A secure and reliable PACS should be able to minimize the risk of accidental data destruction, and should prevent non authorized access to the archive with adequate security measures in relation to the acquired knowledge and based on the technological advances. Archiving of data produced by modern digital imaging is a problem now present also in small Radiology services. The technology is able to readily solve problems which were extremely complex up to some years ago as the connection between equipment and archiving system owing also to the universalization of the DICOM 3.0 standard. The evolution of communication networks and the use of standard protocols as TCP/IP can minimize

  9. Specialized consultant in radiological safety to the north central hospital of high speciality, PEMEX. I. - May-June of 2003

    International Nuclear Information System (INIS)

    Angeles C, A.; Camacho V, B.; Rodriguez A, F.

    2003-09-01

    The north central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  10. Specialized consultant in radiological safety to the clinical north central hospital of high speciality, PEMEX. IV. - December of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    The clinical north central hospital of high speciality, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  11. Specialized consultant in radiological safety to the Ciudad del Carmen general hospital, PEMEX. III.- September and October of 2002

    International Nuclear Information System (INIS)

    Angeles C, A.; Rodriguez A, F.; Garcia A, J.

    2003-02-01

    The Ciudad del Carmen general hospital, dependent of PEMEX, It request consultant of the ININ to be able to maintain their sanitary license for the use of X-ray equipment for the radiologic diagnostic.The proposal of the ININ was to be a program of technical attendance, schedule monthly to be able to solve the observations that are presented in the use of those equipment, and that the hospital can conserve its respective sanitary license.(Author)

  12. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  13. Medical Ethics in Radiology

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Park, Jae Hyung; Yoon, Soon Ho

    2010-01-01

    According to the recent developments in radiological techniques, the role of radiology in the clinical management of patients is ever increasing and in turn, so is the importance of radiology in patient management. Thus far, there have been few open discussions about medical ethics related to radiology in Korea. Hence, concern about medical ethics as an essential field of radiology should be part of an improved resident training program and patient management. The categories of medical ethics related with radiology are ethics in the radiological management of patient, the relationship of radiologists with other medical professionals or companies, the hazard level of radiation for patients and radiologists, quality assurance of image products and modalities, research ethics, and other ethics issues related to teleradiology and fusion imaging. In order to achieve the goal of respectful progress in radiology as well as minimizing any adverse reaction from other medical professions or society, we should establish a strong basis of medical ethics through the continuous concern and self education

  14. ATIVIDADES CORPORAIS AQUÁTICAS EM ESPECIAL O MERGULHO E O DESENVOLVIMENTO DO PSIQUISMO

    Directory of Open Access Journals (Sweden)

    Celi Taffarel

    2015-04-01

    Full Text Available O presente estudo situa-se entre os que investigam o desenvolvimento do psiquismo ressaltando o papel da educação escolar e o acesso ao conhecimento clássico sobre as atividades corporais aquáticas, e dentre elas o mergulho, no desenvolvimento dos processos funcionais, através do ensino e da aprendizagem de conteúdos nucleares na escola. Objetivo:Analisar o desenvolvimento do psiquismo à luz da psicologia histórico-cultural e propor o trato com o conhecimento clássico sobre atividades aquáticas, em especial o mergulho, a luz da pedagogia histórico-critica, defendendo este conhecimento como nuclear no currículo escolar, nos estudos sobre a relação “ser humano-água”, para a elevação da capacidade teórica dos estudantes, através da metodologia do ensino critico-suparadora.

  15. Assessment of nuclear medicine capabilities in responding to a radiological terrorism event. Technical memorandum

    Energy Technology Data Exchange (ETDEWEB)

    Stodilka, R.Z. [Univ. of Western Ontario, Schulich School of Medicine, London, Ontario (Canada); Wilkinson, D

    2006-09-15

    Substantial effort has been placed into enhancing federal capabilities for responding to a Chemical, Biological, Radiological, or Nuclear (CBRN) terrorist attack. However, little emphasis has been placed on including the local-level medical responders in these efforts. In effecting response to a radiological incident, potentially useful resources to access are health care professionals with training in matters of ionizing radiation, namely: nuclear medicine physicians, radiologists, radiation oncologists, medical physicists, and technologists. In this report, we focus on Nuclear Medicine expertise in Canada, and place this expertise into the context of assisting with a radiological terrorist incident. Nuclear Medicine expertise, along with its supporting infrastructure has already been deployed in proportion to the distribution of the civilian population. Given the expectations that the civilian population places in these health care professionals, their immediate access to specialized equipment, and the delay between a radiological terrorist incident and the arrival of federal expert capabilities, it is likely that these health care professionals will play important roles in emergency response. These roles will likely be: identifying the nature of the incident, triage, decontamination, coordinating with First Responders, and communicating with the media. Acknowledging the potential value of these professionals in responding to a radiological terrorist incident, steps should be taken to enlist their support and integrate them into a coherent national strategy. (author)

  16. Assessment of nuclear medicine capabilities in responding to a radiological terrorism event. Technical memorandum

    International Nuclear Information System (INIS)

    Stodilka, R.Z.; Wilkinson, D.

    2006-09-01

    Substantial effort has been placed into enhancing federal capabilities for responding to a Chemical, Biological, Radiological, or Nuclear (CBRN) terrorist attack. However, little emphasis has been placed on including the local-level medical responders in these efforts. In effecting response to a radiological incident, potentially useful resources to access are health care professionals with training in matters of ionizing radiation, namely: nuclear medicine physicians, radiologists, radiation oncologists, medical physicists, and technologists. In this report, we focus on Nuclear Medicine expertise in Canada, and place this expertise into the context of assisting with a radiological terrorist incident. Nuclear Medicine expertise, along with its supporting infrastructure has already been deployed in proportion to the distribution of the civilian population. Given the expectations that the civilian population places in these health care professionals, their immediate access to specialized equipment, and the delay between a radiological terrorist incident and the arrival of federal expert capabilities, it is likely that these health care professionals will play important roles in emergency response. These roles will likely be: identifying the nature of the incident, triage, decontamination, coordinating with First Responders, and communicating with the media. Acknowledging the potential value of these professionals in responding to a radiological terrorist incident, steps should be taken to enlist their support and integrate them into a coherent national strategy. (author)

  17. Analysis of papers in radiological journals in recent years: a comparison of journal of Korean radiologic society and radiology

    International Nuclear Information System (INIS)

    Kim, Jin Suh; Kim, Jae Kyun; Han, Dong Bok; Lim, Tae Hwan

    1997-01-01

    The purpose of this study was to determine current trends and the mode of future development in the field of medical radiology and to promote research among the nation's radiologists by analyzing the contents of the Journal of the Korean Radiologic Society(JKRS) and Radiology. The number of articles published in JKRS each year between 1990 and 1994 was counted. The research articles in JKRS(n=740) and in Radiology(n=1748) between 1992 and 1994 were categorized according to the objective, type, topic, materials, and radiologic techniques of their contents on the basis of predetermined criteria. Domestic Masters theses(n=126) and doctoral dissertations(n=75) accepted between 1990 and 1994, and domestic materials published in international journals (n=416) between 1986 and 1994 were also categorized using the same criteria. The greatest increase in the number of articles published in JKRS was seen during 1994. The majority of these aimed to retrospectively analyse the findings of diseases while the majority of articles published in Radiology dealt prospectively with the development and/or evaluation of diagnostic methods. More variety of topics and issues was seen in Radiology than in JKRS. The number of articles of domestic materials published in international journals increased from 1986 to 1994, while the number of articles of foreign materials published in Korea was relatively stationary : A significant number of theses and dissertations dealt, mostly prospectively, with studies of pathophysiologic and/or pharmacologic mechanisms using animal models. In order to understand both current trends and the direction and mode of future developments in the field of radiology, and to be able to actively deal with challenges at the forefront of radiologic development, it is essential to review research articles published in radiology-related journals

  18. A taxa de câmbio no centro da teoria do desenvolvimento

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Bresser-Pereira

    2012-08-01

    Full Text Available Este artigo apresenta as principais ideias da macroeconomia estruturalista do desenvolvimento - a teoria por trás de novo-desenvolvimentismo. Seu foco é a taxa de câmbio que é pela primeira vez colocada no centro da economia do desenvolvimento. A teoria econômica geralmente vê a taxa de câmbio como um problema de curto prazo a ser discutido na macroeconomia. A macroeconomia estruturalista do desenvolvimento mostra que há, nos países em desenvolvimento, a tendência à sobreapreciação cíclica da taxa de câmbio causada pela falta de neutralização da doença holandesa e por entradas de capital excessivas. Em consequência, considera a taxa de câmbio cronicamente sobreapreciada e, por isso, um grande obstáculo ao crescimento econômico. No processo de desenvolvimento, a taxa de câmbio tem a função de um interruptor de luz que conecta ou desconecta as empresas nacionais que utilizam a tecnologia no estado da arte mundial dos mercados mundiais.This paper presents the main ideas of structuralist development macroeconomics - the theory behind new developmentalism. Its focus is on the exchange rate that is positioned for the first time in the core of development economics. Economic theory usually views the exchange rate as a short term problem to be discussed in open macroeconomics. Structuralist development macroeconomics argues that there is in developing countries a tendency to the cyclical overvaluation of the exchange rate caused by the lack of neutralization of the Dutch disease and by excessive capital inflows. In consequence it views the exchange rate as chronically overvalued, and, for that reason, a major obstacle to economic growth. In the development process, the exchange rate has the role of light switch that connects or disconnects the national business enterprises utilizing technology in the world state of the art from world markets.

  19. A Cooperação Triangular e as Transformações da Cooperação Internacional para o Desenvolvimento

    OpenAIRE

    Bruno Ayllón Pino

    2013-01-01

    Nas últimas décadas, a Cooperação Internacional para o Desenvolvimento (CID) tem experimentado modalidades alternativas de execução, integrando países desenvolvidos, países em desenvolvimento e organismos multilaterais em formatos triangulares. Em um contexto de crise econômica, as limitações da CID para promover o desenvolvimento, somadas às dúvidas sobre o cumprimento dos compromissos financeiros dos doadores da Organização para a Cooperação e Desenvolvimento Econômico (OCDE), propiciaram o...

  20. Desenvolvimento inicial de mudas de Butia odorata (Barb. Rodr. Noblick cultivadas em recipientes

    Directory of Open Access Journals (Sweden)

    Claudimar Sidnei Fior

    2014-10-01

    Full Text Available Butia odorata (Barb.Rodr. Noblick (butiazeiro é uma palmeira nativa do sul do Brasil, com grande demanda para usos ornamental e agroindustrial. O objetivo deste estudo foi avaliar o desenvolvimento inicial de mudas de butiazeiro, em recipientes com diferentes composições de substratos. O experimento foi desenvolvido em casa de vegetação sem controle de temperatura e umidade. Foram utilizadas mudas com 60 dias após a germinação, e avaliados os substratos, em cinco proporções, dos componentes casca de arroz carbonizada e casca de pinus. Em etapa posterior, monitorou-se o efeito do pH do substrato no desenvolvimento das mudas mantidas nos mesmos recipientes e tratamentos. Para tanto, as plantas foram distribuídas em igual número e representação dos tratamentos, em quatro grupos, com quatro níveis de pH do substrato (4,0; 4,9; 5,8 e 6,7. Noventa dias após o início da primeira etapa, e 161 dias após o início da segunda, foram avaliados o desenvolvimento das plantas, a condutividade elétrica e o pH dos substratos. Na primeira etapa, constatou-se diferença entre os tratamentos somente para altura das plantas e pH do substrato, ambas relacionadas diretamente com a proporção de casca de pinus na formulação. Na segunda etapa, a composição do substrato foi determinante para o maior desenvolvimento das mudas. Somente o número de folhas não apresentou diferença significativa entre os tratamentos. Contudo, para todas as variáveis, a presença de casca de pinus, mesmo em baixa proporção, foi suficiente para favorecer o desenvolvimento vegetativo.

  1. Radiological protection challenges at B.N.G. Sellafield

    International Nuclear Information System (INIS)

    Hallard, R.; Anderson, B.; Hutton, E.

    2006-01-01

    The UK Nuclear Industry is in the midst of a period of intense change with the formation of a national body to manage the clean up of Nuclear facilities. Previous owners of nuclear sites have become contractors and the emphasis has switched from production facilities for power or reprocessing to decommissioning and clean up. Many of the older facilities were not designed for decommissioning and now require attention to reduce risks. Sellafield represents a microcosm of the industry with operating and production facilities, waste storage facilities and plants awaiting or undergoing decommissioning. The experience already gained in decommissioning of redundant facilities over the last decade is being used to develop an accelerated response to clean up of the past. The major challenge is to accommodate the changes whilst monitoring and improving Radiological standards and performance. This paper describes a number of issues to which the site must be managed to ensure that the current Radiological performance is maintained and improved. The dose control arrangements for some 6000 radiation workers on the site requires a change in approach as we move towards localised project based systems with an increasingly mobile workforce. Work is proceeding to introduce a new generation of short term dose control equipment with an emphasis on safety culture and management responsibilities for dose control. The achievement and demonstration of ALARP in these circumstances, is being reviewed in situations where timescale, overall risk to public and workforce and exposure to non radiological hazards are factors. Clean up requires more attention to clearance of materials and this aspect has an increasing profile to recognize the need to balance risk and expenditure. The paper will review the current Radiological Protection challenges to the changing Nuclear Industry using the Sellafield site as the prime example and will discuss achievements and areas where further work is necessary

  2. State-of-the-art of dentistry radiological services

    International Nuclear Information System (INIS)

    Yacovenco, Alejandro; Tauhata, Luiz; Infantosi, Antonio F.C.

    2001-01-01

    There are estimated that the dental X-ray participates today with about 20% of the total number of radiological exams accomplished at the country. According to data of the National Commission of Nuclear Energy (CNEN) more than 80% of the radiological exams are accomplished internationally with superior doses to the limits accepted. That picture, ally to an inefficient acting of X-ray apparels and the obtaining of radiological images of low diagnose quality did not suffer alterations for more than 20 years, in spite of a series of initiatives and attempts of the part of CNEN. Before this problematic one the work of implementation of the Quality Assurance System it was in evidence for the reached results. In an unpublished work, counting with the participation of the private initiative, begun with an understanding work and the surgeon's dentist's motivation, to give support for the procedures be it accomplished and basing on the control of the equipment and in the measure of the radiations in correct metrological way, it was gotten to modify the distribution of the dose absorbed in the entrance of the skin. As more important results stand out the improvement in the processing of the film in more than 46% of the dental clinics, reduction of the time of exhibition in more than 70% of the apparels of X-rays and a reduction of the dose of the order of 76%. (author)

  3. Patients Radiation Load Caused by Digitalised X-Ray Equipment

    International Nuclear Information System (INIS)

    Nikodemova, D.; Prikazska, M.; Horvathova, M.

    2001-01-01

    Full text: The radiation load of population all over the world from medical examinations clearly demonstrate the importance of implementation of quality assurance and quality control programmes into the activities of radiological departments. The basic aim of quality assurance programme is to ensure that the radiation dose is kept as low as reasonably practicable consistent with adequate image quality. As many other fields, the rapid development of techniques brought change-over from the conventional analogue technique to the digital technique. In this connection conventional X-ray film is being abandoned and images are being viewed on either laser film or monitor. The main advantages of using digital equipment lay in improved image quality and diagnostic accuracy through digital image processing, reduction in patient exposure, cost reduction by reduction film usage, more efficient storage and retrieval of radiographic images through picture archiving. Several studies that have been conducted for comparison of various diagnostic examinations performed on digital and analogue X-ray equipment have shown that in barium meal examinations, there is potential for dose saving in the digital image intensifier technique. The aim of this study was to compare measured values of dose-area product for colon investigations using different X-ray equipment types, on digital and one analogue. Our material consisted of 60 randomly selected patients, 24 of them were examined with digital equipment and 36 patients with the analogue equipment. (author)

  4. Automated system for the management of the radiological safety in a radiopharmaceutical and labelled compounds production center

    International Nuclear Information System (INIS)

    Amador B, Z.H.; Alvarez Builla de Sologuren, E.

    2006-01-01

    The establishment in the Center of Isotopes of Cuba of a managerial quality system in matter of radiological safety Y the accumulated operational experience, its constitute the foundations for the development of a system of management of the radiological safety organically structured, with the application of evaluative techniques of it management Y it integration in an automated system. The Visual Basic 5 platform for the programming of the 'SASR' system is used. The functions of each one of the 11 modules that integrate it are described. With this it can be carried out the registration of the data of the training Y the personnel's authorization, the checkup of the radioactive inventory of the installation, the annual upgrade of the registrations of the individual doses of those workers, the analysis of the state of the available equipment for magnitude to control, the radiological situation of the work positions, the public exposure by the gassy discharges, the experiences of the radiological events, the annual consolidation of the costs of the safety Y the evaluation of indicators Y of tendencies. A computer tool that facilitates the effective management of the radiological safety in a radioactive installation is obtained. (Author)

  5. Charles Darwin: um observador do desenvolvimento humano

    Directory of Open Access Journals (Sweden)

    Eloisa Helena Rubello Valler Celeri

    2010-12-01

    Full Text Available Os autores traduzem, pela primeira vez para o português, o artigo de Charles Darwin "A Biographical Sketch of an Infant", publicado no periódico Mind em julho de 1877. Utilizando anotações de observações do desenvolvimento de seus filhos, especialmente de seu filho mais velho William Erasmus (Doddy, Darwin descreve e estuda, a partir de seu enfoque naturalista, o filhote humano, narrando os primeiros indicativos comportamentais de emoções tais como raiva e medo, curiosidade e senso moral, o brincar e o prazer envolvido nesta atividade, a capacidade de imitação e os primeiros indícios daquilo que hoje conhecemos como "teoria da mente". Colocando-se questões sobre as capacidades do bebê, como eles aprendem e como se comunicam e levantando hipóteses sobre possíveis significados de certos comportamentos, questões ainda hoje fundamentais para o estudo do desenvolvimento humano, Darwin mostra-se também um pioneiro no estudo do bebê e da criança pequena, numa época na qual as capacidades dos bebês eram extremamente subestimadas e desconsideradas.

  6. Radiological control criteria for materials considered for recycle and reuse

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Hill, R.L.; Aaberg, R.L.; Wallo, A. III

    1994-11-01

    Pacific Northwest Laboratory (PNL) is conducting technical analyses to support the US Department of Energy (DOE), Office of Environmental Guidance, Air, Water, and Radiation Division (DOE/EH-232) in developing radiological control criteria for recycling or reuse of metals or equipment containing residual radioactive contamination from DOE operations. The criteria, framed as acceptable concentrations for release of materials for recycling or reuse, are risk-based and were developed through analysis of generic radiation exposure scenarios and pathways. The analysis includes evaluation of relevant radionuclides, potential mechanisms of exposure, and non-health-related impacts of residual radioactivity on electronics and film. The analysis considers 42 key radionuclides that DOE operations are known to generate and that may be contained in recycled or reused metals or equipment. Preliminary results are compared with similar results reported by the International Atomic Energy Agency, by radionuclide grouping

  7. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  8. O Estado (de Bem-Estar Social como Ator do Desenvolvimento: Uma História das Ideias

    Directory of Open Access Journals (Sweden)

    Celia Lessa Kerstenetzky

    2015-09-01

    Full Text Available Reconstruímos neste artigo uma história das ideias, abstratas ou incorporadas em práticas concretas, da ação estatal voltada ao desenvolvimento, da concepção de "Estados-poder" a "Estados de Bem-Estar", seguindo o fluxo e o refluxo de argumentos em favor da intervenção. Justificativas de intervenção baseadas na necessidade de superar descontinuidades econômicas são contrapostas a argumentos que apontam os riscos e antídotos da captura do Estado por interesses privados, bem como à abordagem mais ampla ao desenvolvimento de Amartya Sen. Experiências nacionais de desenvolvimento e de Estado de Bem-Estar Social são também rastreadas, como "ideias incorporadas". Identificamos uma defesa da intervenção do Estado que integra os campos econômico, político e social e aponta a democracia e o Estado de Bem-Estar como temas emergentes no discurso do desenvolvimento.

  9. SU-E-E-01: ABR Diagnostic Radiology Core Exam: Was Our Redesigned Physics Course Successful in Teaching Physics to Radiology Residents?

    International Nuclear Information System (INIS)

    Kanal, K; Hoff, M; Dickinson, R; Zamora, D; Stewart, B

    2014-01-01

    Purpose: Our purpose is to evaluate the effectiveness of our two year physics course in preparing radiology residents for the American Board of Radiology (ABR) diagnostic radiology exam. Methods: We designed a new two-year physics course that integrates radiology clinical content and practice and is primarily based on the AAPM curriculum and RSNA/AAPM physics modules. Biweekly classes focus on relevant concepts from assigned reading and use audience response systems to encourage participation. Teaching efficiency is optimized through lecturer rotations of physicists, radiologists, and guest speakers. An emphasis is placed on clinical relevance by requiring lab work and providing equipment demonstrations. Periodic quiz were given during the course. The course website was also redesigned for usability, and physics review lectures were conducted two weeks before the board exam to refresh key concepts. At the completion of our first two-year course, we conducted a confidential evaluation of the faculty and course. The evaluation assessed metrics such as overall organization, clinical relevance of content, and level of difficulty, with a rating scale from poor to excellent. Results: Our evaluation indicated that the redesigned course provided effective board exam preparation, with most responses between good and excellent. There was some criticism on the course length and on chronological discontinuity, but the review lectures were appreciated by the residents. All of our residents passed the physics component of the ABR exam with scores exceeding the minimum passing score by a significant margin. Conclusion: The course evaluation and board exam results indicate that our new two-year course format provides valuable board exam preparation. This is possible thanks to the time and effort taken by the physics faculty on ensuring the residents get quality physics education

  10. Resiliência e Justiça Organizacional como Antecedentes da Percepção de Desenvolvimento Profissional

    Directory of Open Access Journals (Sweden)

    Ana Claudia Monteiro

    Full Text Available RESUMO O mercado competitivo da atualidade tem exigido mais qualificação dos trabalhadores, o que aumenta a relevância do construto desenvolvimento profissional. O objetivo deste estudo foi testar um modelo de predição da percepção do desenvolvimento profissional. Participaram da pesquisa 320 trabalhadores de diferentes categorias profissionais de organizações públicas e privadas. O questionário continha três escalas, todas com bons indicadores psicométricos. Os resultados apontados a partir da regressão múltipla confirmaram que percepção de justiça organizacional e resiliência predizem positivamente a percepção de desenvolvimento profissional, sendo que esta demonstra maior poder preditivo. Os resultados foram discutidos de acordo com a teoria do desenvolvimento profissional.

  11. Conventional radiology: fixed installations in medical environment

    International Nuclear Information System (INIS)

    2010-01-01

    This document presents the different procedures, the different types of specific hazards, the analysis of risks, their assessment and the preventive methods with regard to radioprotection in the case of fixed conventional radiology equipment in medical environment. It indicates and describes the concerned personnel, the course of procedures, the hazards, the identification of the risk associated with ionizing radiation, the risk assessment and the determination of exposure levels (definition of regulated areas, personnel categories), the strategy aimed at controlling the risk (risk reduction, technical measures concerning the installation or the personnel, teaching and information, prevention, incident), the different measures of medical monitoring, the assessment of risk control, and other risks. An appendix proposes an example of workstation assessment

  12. Processo de desenvolvimento e coordenação de projetos na construção civil: um estudo multi-caso em empresas de Belém (PA)

    OpenAIRE

    NEDER, Cláudia Regina Bastos

    2010-01-01

    Este trabalho faz uma reflexão sobre a coordenação de projetos na indústria da construção de edifícios, identifica as etapas do processo de projeto, aponta a participação da equipe de projeto, durante as atividades de coordenação, apresenta a atuação do coordenador de projetos e sistematiza os procedimentos de controle e retroalimentação. Para desenvolver a pesquisa, foram realizados estudos bibliográficos sobre a Gestão e Coordenação de Projetos, no desenvolvimento do processo de proje...

  13. Specialized consulting in radiological safety to the North Central Hospital of high specialty, PEMEX. V. November of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J. A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    It is a report of a specialized consulting in radiological safety that to be carried the ININ to PEMEX for the North Central Hospital of High Specialty, to maintain the sanitary license for the use of X ray equipment of medical diagnostic, and guarantee these services with a program of quality assurance. To give fulfilment to that requests it is programmed a technical assistance monthly, with reports of results during the development of the service. In this document it is carried a report of the advances and results in the month of November of the 2001, where the following documents are analyzed: Manual of radiological safety, program of quality assurance, operation procedures, procedure of maintenance team, procedure of medical radiological control of the specialized personnel; also are annotate the obtained results and their observations. (Author)

  14. Specialized consulting in radiological safety to the south central hospital of high specialty, PEMEX. VI. December of 2001

    International Nuclear Information System (INIS)

    Angeles C, A.; Vizuet G, J.; Benitez S, J.A.; Garcia A, J.; Rodriguez A, F.

    2002-01-01

    It is a report of a specialized consulting in radiological safety that to be carried the ININ to PEMEX for the South Central Hospital of High Specialty, to maintain the sanitary license for the use of X-ray equipment of medical diagnostic, and guarantee these services with a program of quality assurance. To give fulfilment to that requests it is programmed a technical assistance monthly, with reports of results during the development of the service. In this document it is carried a report of the advances and results in the month of december of the 2001, where the following documents are analyzed: Manual of radiological safety, program of quality assurance, operation procedures, procedure of maintenance team, procedure of medical radiological control of the specialized personnel; also are annotate the obtained results and their observations. (Author)

  15. Mesorregião Grande Fronteira do Mercosul: perfil locacional do desenvolvimento regional

    Directory of Open Access Journals (Sweden)

    Jandir Ferrera de Lima

    2010-05-01

    Full Text Available O objetivo deste artigo é analisar o perfil das desigualdades regionais na área de abrangência na região Grande Fronteira do Mercosul (GFM, através da mensuração do coeficiente de desenvolvimento regional e do padrão de localização do emprego formal. No âmbito dessa análise ficaram demonstrados dois fenômenos espaciais: um processo de reestruturação espacial e a forte desigualdade das mesorregiões Sudoeste PR, Noroeste RS e Fronteira Oeste RS em relação às outras mesorregiões do Sul do Brasil. Esse resultado fortalece a identificação de particularidades espaciais capazes de esclarecer um padrão de desenvolvimento econômico regional diferenciado nas fronteiras, em particular na Região Sul do Brasil. Os resultados deste estudo forneceram elementos para a intervenção regional, pois é possível, via políticas públicas adequadas, buscar a retomada do dinamismo econômico e o desenvolvimento socioeconômico na GFM.

  16. Radiological protection of patients

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.

    2003-01-01

    The benefits of ionizing radiation in the diagnosis and treatment of cancer, as well as other conditions such as cardiac ablation, are well established. However determination, monitoring, and evaluation of patient doses is not as easy task. Furthermore, radiation doses for individual patients may vary greatly from one radiological procedure to another. Attention is needed to reduce unnecessary radiation exposure to patients from All types of radiation producing machines and equipment. The patient risk from radiation injury-stochastic and/or deterministic must be weighted against the benefits of a proper medical examination or treatment as well as the risk of depriving the patient from the necessary medical care. Arbitrary reduction of radiological patient doses without regard to final outcome is determined to proper medical care provided to the patient. Sacrificing image quality in order to reduce patient dose is potentially harmful to the patient as well. Furthermore, the role of radiation exposure incurred from screening procedures such as mammography, needs to be properly considered and differentiated from medically indicated procedures. A known radiation induced risk needs to be balanced against diagnostic efficacy of a screening procedure. In these cases, regulations on standards and guidelines for determination, monitoring, and evaluation of patient doses may be appropriate. In this paper, the technical data collected in the United States have been compared with the corresponding data in Canada. However, even here, it has been recognized that we can not assume that one dose limit fits all. It is advisable to consider individual patient specifics if it means the difference between detection and miss

  17. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal A.; Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dwyer, Kathy; Yu-Moe, Winnie [CRICO Risk Management Foundation, Boston, MA (United States)

    2017-06-15

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality

  18. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    International Nuclear Information System (INIS)

    Breen, Micheal A.; Taylor, George A.; Dwyer, Kathy; Yu-Moe, Winnie

    2017-01-01

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality implicated in

  19. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims.

    Science.gov (United States)

    Breen, Micheál A; Dwyer, Kathy; Yu-Moe, Winnie; Taylor, George A

    2017-06-01

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality implicated in

  20. Estilos parentais e personalidade: competências sociais e o desenvolvimento do processo resiliente

    OpenAIRE

    Ferreira, Sara Patrícia Duarte

    2016-01-01

    Dissertação de Mestrado em Psicologia Clínica De acordo com a literatura, as vivências afetivas e relacionais experienciadas no seio familiar, nomeadamente na relação entre pais-filhos, têm um papel privilegiado no desenvolvimento dos jovens. Nesta medida, postula-se que um estilo parental baseado na assertividade e responsividade assuma um papel significativo e protetor face ao desenvolvimento de características e competências adaptativas dos adolescentes e jovens adultos. A presente inve...