WorldWideScience

Sample records for radioisotope color scan

  1. Findings of the radioisotope color scan of the hepatic metastases

    International Nuclear Information System (INIS)

    Choi, M. S.; Yoo, H. S.; Park, C. Y.; Choi, B. S.

    1975-01-01

    Recently, the space occupying lesions in the liver were well established and recognized by radioisotope color scan. In addition, the lesions were easily localized in the supine and the right lateral projections. The findings of hepatoma, abscess and cyst were seen as filling defects which were similar to the findings of the hepatic metastases. In this study, we analysis of 70 cases of the hepatic metastases, 80 cases of the hepatoma and 100 cases of the liver abscess which were obtained by radiogold color scan and confirmed by a needle biopsy or laparotomy. Summary of analysis as follows: 1. Primary site in 70 cases of hepatic metastases. Stomach 30 cases (42.8%) Biliary Tract 10 cases (12.3%) Colon 8 cases (11.4%) Lung 6 cases (8.5%) Ovary 6 cases (8.5%) Pancreas 3 case (4.3%) Thyroid 2 cases (3.5%) Breast 2 cases (3.5%) Kidney, Cervix, Esophagus 1 case. 2. Hepatomegaly were seen in 22 cases (32%) of the hepatic metastases and relatively small in percentage compare with the hepatoma and abscess. 3. Single space occupying lesion were demonstrated in 26 cases (35.7%) of the hepatic metastases, 55 cases (70.2%) of the hepatoma and 72 cases (72%) of the abscess. Two space occupying lesion were in the scan in 10 cases (12.3%) of the hepatic metastases, 8 cases (9.5%) of the hepatoma and 10 cases (10%) of the abscess. Multiple space occupying lesions were scan in 15 cases (21.4%) of the hepatic metastases, 14 cases (17.5%) of the hepatoma and 13 cases (13%) of the abscess. Compare with the hepatoma and abscess, the hepatic metastases tend to more than one space occupying lesions. 4. The appearance and location of the metastatic lesions showed somewhat significant. In 26 of 30 cases (81.6%) of the stomach carcinoma revealed the lesions mostly located in the porta hepatis and right lower lobe of the liver. Multiple and discrete metastatic lesions were usually from the colon carcinoma.

  2. Findings of the radioisotope color scan of the hepatic metastases

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M S; Yoo, H S; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1975-06-15

    Recently, the space occupying lesions in the liver were well established and recognized by radioisotope color scan. In addition, the lesions were easily localized in the supine and the right lateral projections. The findings of hepatoma, abscess and cyst were seen as filling defects which were similar to the findings of the hepatic metastases. In this study, we analysis of 70 cases of the hepatic metastases, 80 cases of the hepatoma and 100 cases of the liver abscess which were obtained by radiogold color scan and confirmed by a needle biopsy or laparotomy. Summary of analysis as follows: 1. Primary site in 70 cases of hepatic metastases. Stomach 30 cases (42.8%) Biliary Tract 10 cases (12.3%) Colon 8 cases (11.4%) Lung 6 cases (8.5%) Ovary 6 cases (8.5%) Pancreas 3 case (4.3%) Thyroid 2 cases (3.5%) Breast 2 cases (3.5%) Kidney, Cervix, Esophagus 1 case. 2. Hepatomegaly were seen in 22 cases (32%) of the hepatic metastases and relatively small in percentage compare with the hepatoma and abscess. 3. Single space occupying lesion were demonstrated in 26 cases (35.7%) of the hepatic metastases, 55 cases (70.2%) of the hepatoma and 72 cases (72%) of the abscess. Two space occupying lesion were in the scan in 10 cases (12.3%) of the hepatic metastases, 8 cases (9.5%) of the hepatoma and 10 cases (10%) of the abscess. Multiple space occupying lesions were scan in 15 cases (21.4%) of the hepatic metastases, 14 cases (17.5%) of the hepatoma and 13 cases (13%) of the abscess. Compare with the hepatoma and abscess, the hepatic metastases tend to more than one space occupying lesions. 4. The appearance and location of the metastatic lesions showed somewhat significant. In 26 of 30 cases (81.6%) of the stomach carcinoma revealed the lesions mostly located in the porta hepatis and right lower lobe of the liver. Multiple and discrete metastatic lesions were usually from the colon carcinoma.

  3. A storage and display method for radioisotope imaging using scan conversion memory

    International Nuclear Information System (INIS)

    Takizawa, Masaomi; Kobayashi, Toshio; Nakanishi, Fumiko; Suzuki, Shigeo; Miyabayashi, Hiroyasu

    1975-01-01

    The scan conversion memory (SCM) has been applied to a method for the storage and display of radioisotope images. Scan data were fed into SCM as pulse signals with X and Y axis from the scinti-scanner or the scinti-camera. The electric charge on the SCM target is directly proportional to the pulse density. A TV display was executed immediately after the recording of a radioisotope image. If necessary, a seven additive color display to the image density could be obtained by a simple color slicer, and the image could be hard-copied by a video hard-copy printer. Characteristics of the SCM were experimentally clarified as follows: the practical resolution was 700 line/TV; ten levels gray scale were discriminated on the video monitor, the uniformity, measured by an oscilloscope was less than 20%, and dead time of the pulse interval at full scale signal was 5 μ sec. In their representation, the SCM scintigrams were observed as closely resembling conventional film scintigrams. Superimposed imaging of an X-ray picture and a radioisotope image can be realized by using the SCM, for an increase in anatomical localization on reading images. The SCM scintigram can be applied rapidly and can be the viewer of radioisotope imaging. (auth.)

  4. Medical Radioisotope Scanning, Vol. II. Proceedings of the Symposium on Medical Radioisotope Scanning

    International Nuclear Information System (INIS)

    1964-01-01

    Medical applications of radioisotopes continue to grow in number and importance and medical centres in almost all countries of the world are now using radioactive materials both in the diagnosis and treatment of disease. An increasing proportion of these applications involves studies of the spatial distribution of radioactive material within the human body, for which purpose highly specialized scanning methods have been elaborated. By these methods it is possible to study the position, size and functional state of different organs, to detect tumours, cysts and other abnormalities and to obtain much useful information about regions of the body that are otherwise inaccessible, except by surgery. Progress in scanning methods in recent years has been very rapid and there have been many important advances in instrumentation and technique. The development of new forms of the gamma camera and of colour-scanning techniques are but two examples of recent improvements. The production of new radioisotopes and new labelled compounds has further extended the scope of these methods. To survey these new advances the International Atomic Energy Agency held a Symposium on Medical Radioisotope Scanning in Athens from 20-24 April 1964. The scientific programme of the meeting covered all aspects of scanning methods including theoretical principles, instrumentation, techniques and clinical applications. The World Health Organization assisted in the selection of papers by providing a consultant to the selection committee. The meeting followed the earlier IAEA/WHO Seminar on Medical Radioisotope Scanning in Vienna in 1959, which was attended by 36 participants and at which 14 papers were presented. Some idea of the growth of interest in the subject may be gained from the fact that the Symposium was attended by 160 participants from 26 countries and 4 international organizations, and that 58 papers were presented. The published proceedings, comprising two volumes, contain all the

  5. Evaluation of processing methods for static radioisotope scan images

    International Nuclear Information System (INIS)

    Oakberg, J.A.

    1976-12-01

    Radioisotope scanning in the field of nuclear medicine provides a method for the mapping of a radioactive drug in the human body to produce maps (images) which prove useful in detecting abnormalities in vital organs. At best, radioisotope scanning methods produce images with poor counting statistics. One solution to improving the body scan images is using dedicated small computers with appropriate software to process the scan data. Eleven methods for processing image data are compared

  6. Thyroiditis: Radioisotope Scan Findings and Clinical Significance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Chae; Han, Duck Sup; Park, Jung Suck; Kim, Se Jong; Park, Byung Lan; Kim, Byoung Geun [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    1991-07-15

    We analyzed Radioisotope scan findings of 46 patients of thyroiditis which were proven pathologically at K.C.H. The results were as follows 1) 45 patients were female, one was male and average age of patients was 37 years old. 2) The lesion site was predominant in both lobe (67%) Hashimoto's thyroiditis showed enlarged thyroid (85%) with cold nodule (20%), diffuse decreased activity (10%), while subacute thyroiditis was presented absent activity (53%), poor visualization (20%) or cold nodule (7%). 4) Radioisotope scan was valuable in evaluating function of thyroid gland and detection of lesion but there was a limit of pathological nature.

  7. Medical Radioisotope Scanning. Proceedings of a Seminar

    International Nuclear Information System (INIS)

    1959-01-01

    Of the many and varied uses of radioactive isotopes which have been developed in the past twenty years, their applications in medicine are among the most important. All over the world medical scientists have added radioisotopes to their armament in clinical research, diagnosis and radiotherapy. It is significant that the first scientific meeting organized by the International Atomic Energy Agency was devoted to a medical subject. It is not less significant as a symbol of the close co-operation which has been established between the Agency and other agencies of the United Nations family, that this first seminar was a joint undertaking with the World Health Organization. The determination of the distribution of a radioisotope within the human body - radioisotope scanning - is a technique which has made very rapid progress in the last few years in various medical centres throughout the world, and the necessity of providing an opportunity for an organized exchange of results, experience and opinions was clearly recognised. The value of such an exchange is demonstrated by the extensive discussions which took place and which are recorded in this volume, together with the original papers presented by those who have made such noteworthy contributions to progress in this field.

  8. Medical Radioisotope Scanning. Proceedings of a Seminar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1959-07-01

    Of the many and varied uses of radioactive isotopes which have been developed in the past twenty years, their applications in medicine are among the most important. All over the world medical scientists have added radioisotopes to their armament in clinical research, diagnosis and radiotherapy. It is significant that the first scientific meeting organized by the International Atomic Energy Agency was devoted to a medical subject. It is not less significant as a symbol of the close co-operation which has been established between the Agency and other agencies of the United Nations family, that this first seminar was a joint undertaking with the World Health Organization. The determination of the distribution of a radioisotope within the human body - radioisotope scanning - is a technique which has made very rapid progress in the last few years in various medical centres throughout the world, and the necessity of providing an opportunity for an organized exchange of results, experience and opinions was clearly recognised. The value of such an exchange is demonstrated by the extensive discussions which took place and which are recorded in this volume, together with the original papers presented by those who have made such noteworthy contributions to progress in this field.

  9. Scanning Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1988-01-01

    A confocal color laser microscope which utilizes a three color laser light source (Red: He-Ne, Green: Ar, Blue: Ar) has been developed and is finding useful applications in the semiconductor field. The color laser microscope, when compared to a conventional microscope, offers superior color separation, higher resolution, and sharper contrast. Recently some new functions including a Focus Scan Memory, a Surface Profile Measurement System, a Critical Dimension Measurement system (CD) and an Optical Beam Induced Current Function (OBIC) have been developed for the color laser microscope. This paper will discuss these new features.

  10. Radioisotope scans in the evaluation of metastatic bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Gutierrez, A.C.; Vincent, R.G.; Bakshi, S.; Takita, H.

    1975-01-01

    In this study, we evaluated the accuracy of radioisotope scans in detecting metastatic lesions in patients with bronchogenic carcinoma. To be included in the study, the patient had to have undergone liver, brain, and/or bone scanning within 10 weeks of autopsy. Other means of evaluating these organs for metastatic involvement were used as well. The liver was checked by palpation and by determination of enzyme levels. A history, physical examination, and neurologic examination were used to establish the possibility of brain metastases. For studying bones, a history, physical examination, and conventional x-ray films were employed. Results of the scans and other tests were compared with findings at autopsy, and accuracy rates for each method of study were determined

  11. Role of radioisotope scanning in the coordinated imaging of urinary tract disease

    International Nuclear Information System (INIS)

    Rosenfield, A.T.; Bird, K.I.; Zeman, R.K.

    1988-01-01

    In this chapter, the authors consider approaches to several commonly encountered urinary tract problems. Until recently, the safety and efficacy of a diagnostic study has been the major determinant of its role. Radioisotope imaging of the urinary tract, an extremely safe technique, was generally recommended for any situation in which it was applicable. There are now new factors, cost and speed, that have come to the forefront. Ultrasonagraphy is a technique that is rapid, safe, and for many indications less expensive than scintigraphy. Computed tomography, although less safe than radioisotope scanning, is extremely accurate, relatively rapid, and provides reliable guidance for interventional procedures. In an era of DRGs with extreme pressure on hospitals to make an exact diagnosis early in the patient's stay in order to limit hospitalization time, CT and sonography have become widely used for many applications for isotope scanning. Thus, economics rather than patient comfort and safety may restrict the role of isotope scanning in future patient management. Magnetic resonance imaging, with spectroscopy having the potential to evaluate physiologic parameters, will also compete with scintigraphy in many situations

  12. Glue-sniffing as a cause of a positive radio-isotope brain scan

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, C M; Adams, F G

    1982-08-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas of increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing.

  13. Glue-sniffing as a cause of a positive radio-isotope brain scan

    International Nuclear Information System (INIS)

    Lamont, C.M.; Adams, F.G.

    1982-01-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas if increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing. (orig.)

  14. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  15. A Study on Clinical Activity of Myositis by the Use of Radioisotope Bone Scan in the Patients with Dermatomyositis - polymyositis

    International Nuclear Information System (INIS)

    Choi, Sung Jae; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness of radioisotope bone scan and clinical activity of myositis, bone scan using 99m Tc-Methylene diphosphonate was serially done before and after treatment with prednisolone in 10 patients with well- documented dermatomyositis-polymyositis. The observed results were as follows. 1. In all 10 patients before treatment with prednisolone, the bone scans showed evidence of increased muscle uptake. Muscle uptake was markedly increased in 4 patients, moderately increased in 3 patients and minimally increased in 3 patients. 2. The site of increased muscle uptake was consistent with the site of clinically involved muscle which was weak and tender. 3. The degree of muscle uptake correlated with the severity of the muscle weakness and tenderness at the scan was done. In all 10 patients treated with high dose prednisolone, muscle uptake was decreased following therapy. Above results suggest the radioisotope bone scanning may be useful in the diagnosis and treatment of patient with dermatomyositis-polymyositis.

  16. Theory of Radioisotope Scanning; Theorie de l'Exploration au Moyen d'un Radioisotope; Matematicheskaya osnova radioizotopnogo skennirovaniya; Teoria de la Exploracion Radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G. L. [Massachusetts General Hospital, Boston, MA (United States)

    1964-10-15

    All scanning techniques, whether utilizing focusing collimators, positron detectors or the newer camera techniques, have certain basic problems. The success of these techniques depends in large measure upon the correct choice of various parameters of the collimating system, of which the most important is the resolution. In this paper the relationship of optimum resolution to radioisotope content and distribution are discussed. Radioisotope scanning may be considered as a process of information extraction and presentation. The primary information lies in the original radioisotope distribution. The collimator and detecting system provide the information transfer mechanism and the final scan presents the resultant information. As with all such techniques, only a small fraction of the information is retained in the final scan. It can be shown that for focusing collimator and scintillation camera systems, the number of counts per resolution area varies as the fourth power of the resolution distance. For certain radioisotope distributions it is possible to derive analytically an optimum value of resolution distance. However, for most systems the optimum resolution must be determined by trial and error. The problems here are similar to those of pattern recognition in other fields. A computer programme has been prepared to aid in determining the optimum resolution for various types of patterns. This computer is unique in having intermediate disc storage and CRT read-out. The results have general applicability to the design of many scanning systems. (author) [French] Toutes les methodes d'exploration au moyen d'un radioisotope, celles qui font appel aux collimateurs a focalisation, aux detecteurs de positons ou les techniques plus recentes utilisant des cameras a scintillation, posent certains problemes fondamentaux. Le succes de ces techniques depend beaucoup du choix des differents parametres du dispositif de collimation, dont le plus important est la resolution. L

  17. Storage and analysis of radioisotope scan data using a microcomputer

    Energy Technology Data Exchange (ETDEWEB)

    Crawshaw, I P; Diffey, B L [Dryburn Hospital, Durham (UK)

    1981-08-01

    A data storage system has been created for recording clinical radioisotope scan data on a microcomputer system, located and readily available for use in an imaging department. The input of patient data from the request cards and the results sheets is straightforward as menus and code numbers are used throughout a logical sequence of steps in the program. The questions fall into four categories; patient information, referring centre information, diagnosis and symptoms and results of the investigation. The main advantage of the analysis program is its flexibility in that it follows the same format as the input program and any combination of criteria required for analysis may be selected. The menus may readily be altered and the programs adapted for use in other hospital departments.

  18. Storage and analysis of radioisotope scan data using a microcomputer

    International Nuclear Information System (INIS)

    Crawshaw, I.P.; Diffey, B.L.

    1981-01-01

    A data storage system has been created for recording clinical radioisotope scan data on a microcomputer system, located and readily available for use in an imaging department. The input of patient data from the request cards and the results sheets is straightforward as menus and code numbers are used throughout a logical sequence of steps in the program. The questions fall into four categories; patient information, referring centre information, diagnosis and symptoms and results of the investigation. The main advantage of the analysis program is its flexibility in that it follows the same format as the input program and any combination of criteria required for analysis may be selected. The menus may readily be altered and the programs adapted for use in other hospital departments. (U.K.)

  19. Design of the scanning mode coated glass color difference online detection system

    Science.gov (United States)

    Bi, Weihong; Zhang, Yu; Wang, Dajiang; Zhang, Baojun; Fu, Guangwei

    2008-03-01

    A design of scanning mode coated glass color difference online detection system was introduced. The system consisted of color difference data acquirement part and orbit control part. The function of the color difference data acquirement part was to acquire glass spectral reflectance and then processed them to get the color difference value. Using fiber for light guiding, the reflected light from surface of glass was transmitted into light division part, and the dispersive light was imaged on linear CCD, and then the output signals from the CCD was sampled pixel by pixel, and the spectral reflectance of coated glass was obtained finally. Then, the acquired spectral reflectance signals was sent to industrial personal computer through USB interface, using standard color space and color difference formula nominated by International Commission on Illumination (CIE) in 1976 to process these signals, and the reflected color parameter and color difference of coated glass was gained in the end. The function of the orbit control part was to move the detection probe by way of transverse scanning mode above the glass strip, and control the measuring start-stop time of the color difference data acquirement part at the same time. The color difference data acquirement part of the system was put on the orbit which is after annealing area in coated glass production line, and the protected fiber probe was placed on slide of the orbit. Using single chip microcomputer to control transmission mechanism of the slide, which made the slide move by way of transverse scanning mode on the glass strip, meanwhile, the color difference data acquirement part of the system was also controlled by the single chip microcomputer, and it made the acquirement part measure color difference data when the probe reached the needed working speed and required place on the glass strip. The scanning mode coated glass color difference online detection system can measure color parameter and color difference of

  20. Integro-differential equation analysis and radioisotope imaging systems. Research proposal. [Testing of radioisotope imaging system in phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hart, H.

    1976-03-09

    Design modifications of a five-probe focusing collimator coincidence radioisotope scanning system are described. Clinical applications of the system were tested in phantoms using radioisotopes with short biological half-lives, including /sup 75/Se, /sup 192/Ir, /sup 43/K, /sup 130/I, and /sup 82/Br. Data processing methods are also described. (CH)

  1. Clinical Application of Colour Modulation of Gamma Energy and Depth by Dual-Channel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, E.; Ben-Porath, M. [Veterans Administration Hospital, Hines, IL (United States)

    1969-01-15

    A dual-channel scanning system has been described permitting the simultaneous imaging in individual color of the distribution of two gamma-emitting radioisotopes. In those cases where two organs are adjacent and concentrate the same isotope, they may be displayed in separate color if one of the organs concentrates another gamma-emitting isotope with a different energy. This is accomplished by individual color readout of this isotope and the display of the subtraction of this isotope from the common isotope in another color. By using two facing scintillation probes on either side of the individual being scanned, two overlapping organs at different depths concentrating the same isotope can be color differentiated by a dual-channel playout of each probe. The principal application of these dual-channel scanning methods to date has been the simultaneous display of the liver and pancreas in individual colors using {sup 198}Au and {sup 75}selenomethionine. Characteristic scans have been obtained which differentiate a number of disease states from the normal pancreas and liver. The pancreatic and liver diseases studied and characterized are carcinoma of the pancreas, pancreatic insufficiency, acute recurrent pancreatitis, pancreatic pseudocyst and Laennec's cirrhosis, hepatoma and metastatic malignancy in the liver. The uptake of {sup 75}selenomethionine in malignant lesions in many instances produces positive scans of these tumors in contrasting color to the liver. Depth discrimination in color with the two-probe system has permitted the lateralization of intracranial lesions, the color of the display being proportional to the depth of the lesion. The discrimination of depth and gamma-ray energy by dual-channel color scanning and its general application in visualizing other organs has been accomplished. (author)

  2. Integro-differential equation analysis and radioisotope imaging systems. Research proposal

    International Nuclear Information System (INIS)

    Hart, H.

    1976-01-01

    Design modifications of a five-probe focusing collimator coincidence radioisotope scanning system are described. Clinical applications of the system were tested in phantoms using radioisotopes with short biological half-lives, including 75 Se, 192 Ir, 43 K, 130 I, and 82 Br. Data processing methods are also described

  3. A simple methodology for obtaining X-ray color images in scanning electron microscopy

    International Nuclear Information System (INIS)

    Veiga, M.M. da; Pietroluongo, L.R.V.

    1985-01-01

    A simple methodology for obtaining at least 3 elements X-ray images in only one photography is described. The fluorescent X-ray image is obtained from scanning electron microscopy with energy dispersion analysis system. The change of detector analytic channels, color cellophane foils and color films are used sequentially. (M.C.K.) [pt

  4. Observation of Liver Color Scan

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Y K; Ahn, S B [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  5. Observation of Liver Color Scan

    International Nuclear Information System (INIS)

    Choe, Y. K.; Ahn, S. B.

    1969-01-01

    In the past few years, scintigraphy has become increasingly important in clinical practice, and the use of a color-printing technique has permitted a more accurate interpretation of the scan image. Our liver color scintigrams consist of 51 hepatomas, 35 liver cirrhosis, 22 liver abscesses, 10 hepatitis and other 13 cases of the liver diseases which were clinically and pathologically diagnosed at Severance Hospital, Yonsei Univ. since Feb. 1969 through Sept. 1969. These scintigrams have been analyzed in terms of various pathologic morphology, such as size, shape, margin of the liver, distribution of radioactivity, and shape of the space occupying lesions. The results are as follows: 1) Enlargement of the liver was the most common finding in the diseased livers. The Rt. lobe enlargement was particularly prominent in the liver abscess. 2) Irregular distribution of radioactivity in the liver (so called mottling) was present in 78% of hepatoma, while it was seen only in 31% of liver abscesses. 3) Liver cirrhosis tends to show perihilar accumulation of the isotope (57%). 4) The deformity of the lower most angle of the Rt. lobe, and the Lt. lateral margin of the Lt. lobe was also impressive throughout the cases (74-95% of all diseased livers). 5) The frequency of visualization of the spleen was influenced by the size of space occupying lesions and the amount of functioning liver. 6) Differentiation between the liver abscess and hepatoma seems to be possible on scintigram, when shape an margin of defect and patterns of distribution of radioactivity in the remaining liver are clearly demonstrated.

  6. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  7. RGB color coded images in scanning electron microscopy of biological surfaces

    Czech Academy of Sciences Publication Activity Database

    Kofroňová, Olga; Benada, Oldřich

    2017-01-01

    Roč. 61, č. 3 (2017), s. 349-352 ISSN 0001-723X R&D Projects: GA MŠk(CZ) LO1509; GA ČR(CZ) GA16-20229S Institutional support: RVO:61388971 Keywords : Biological surfaces * Color image s * Scanning electron microscopy Subject RIV: EE - Microbiology, Virology OBOR OECD: Microbiology Impact factor: 0.673, year: 2016

  8. Diagnostic value of radioisotopic cystography in evaluation of VUR in children with urinary tract infection

    International Nuclear Information System (INIS)

    Amiri, M.; Shabestani- Monfared, A.; Derazgisoo, M.

    2002-01-01

    Radioisotope scanning is very important in evaluation, diagnosis and proper treatment of urinary tract infection and vesico ureteral reflux because of high sensitivity of this technique and less radiation dose delivered to the patients. This is a descriptive cross-sectional study to determine the frequency vesico ureteral reflux in a group of children aged 28 days to 14 years referred to our department with diagnosis of urinary tract infection .The radioisotope scanning was conducted for all of patients (30 patients) and the results were analyzed. The results showed that urinary tract infection is seen in wide age group and is usually associated with vesico ureteral reflux . The above findings revealed the important role of radioisotope scanning in early diagnosis and subsequent treatment of urinary tract infection to detect vesico ureteral reflux and prevent subsequent side effects in these patients

  9. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning.

    Science.gov (United States)

    Deferm, Julie T; Schreurs, Ruud; Baan, Frank; Bruggink, Robin; Merkx, Matthijs A W; Xi, Tong; Bergé, Stefaan J; Maal, Thomas J J

    2018-04-01

    The purpose of this study was to assess the feasibility of 3D intraoral scanning for documentation of palatal soft tissue by evaluating the accuracy of shape, color, and curvature. Intraoral scans of ten participants' upper dentition and palate were acquired with the TRIOS® 3D intraoral scanner by two observers. Conventional impressions were taken and digitized as a gold standard. The resulting surface models were aligned using an Iterative Closest Point approach. The absolute distance measurements between the intraoral models and the digitized impression were used to quantify the trueness and precision of intraoral scanning. The mean color of the palatal soft tissue was extracted in HSV (hue, saturation, value) format to establish the color precision. Finally, the mean curvature of the surface models was calculated and used for surface irregularity. Mean average distance error between the conventional impression models and the intraoral models was 0.02 ± 0.07 mm (p = 0.30). Mean interobserver color difference was - 0.08 ± 1.49° (p = 0.864), 0.28 ± 0.78% (p = 0.286), and 0.30 ± 1.14% (p = 0.426) for respectively hue, saturation, and value. The interobserver differences for overall and maximum surface irregularity were 0.01 ± 0.03 and 0.00 ± 0.05 mm. This study supports the hypothesis that the intraoral scan can perform a 3D documentation of palatal soft tissue in terms of shape, color, and curvature. An intraoral scanner can be an objective tool, adjunctive to the clinical examination of the palatal tissue.

  10. Diagnosis of Stomach Carcinoma by Radioisotope Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Czerniak, P.; Meytes, E.; Sinkover, A.; Bank, H. [Tel-Hashomer Government Hospital, University of Tel Aviv School of Medicine (Israel)

    1969-05-15

    Scanning of the stomach after administration of {sup 131}I and {sup 99m}Tc is presented. Experiments on 20 dogs were performed and 105 patients were examined. The studies with {sup 131}I are only mentioned briefly as they have been summarized in a previous publication and we have concentrated on our experience with {sup 99m}Tc and on stomach carcinoma. The turnover of the nuclide in blood, urine, gastric juice and gastric mucosa was tested: in-vivo and post-operative scannings were performed. The scans are classified in four groups. Carcinoma of the stomach results in space-occupying lesions or foggy scans. A correlation of 85 - 90% between scan results and clinical findings is noted. A special group of 10 volunteers was examined to establish the possibility of a screening examination for the detection of stomach cancer using the technique presented. (author)

  11. Applications of radioisotopes in industry and healthcare in Vietnam

    International Nuclear Information System (INIS)

    Dien, N.N.; Quang, N.H.

    1997-01-01

    Nowadays, in Vietnam radioisotopes have been used very widely in various socio-economic branches, especially in industry and healthcare. Applications of radioisotopes have significant meaning in economic development, people health protection, as well as in scientific research. In this paper, the present status and main applications of radiation and radioactive isotopes in industry and healthcare in Vietnam are reported. In order to control and monitor industrial processes, nucleonic control systems and radioactive tracer techniques have been utilized. Actually, sealed source applications are popular in Vietnam industry. A number of nuclear control devices and gauges have been used in the various industrial factories, such as liquid level gauges in steel industry, cement and beverage factories; density and moisture gauges in paper industry, etc. Tracer technique and sealed source applications have also been utilized in industrial production plants and in trouble-shooting in the petroleum industry. For medicine purposes, two departments of nuclear medicine were primarily established at the beginning of the 1970s. At the present time, a number of nuclear medicine departments have been set up and they have been equipped with advanced equipment. Main activities are focused on thyroid function studies, nuclear cardiology, brain scans, gastrointestinal studies, bone scans, etc. Since march 1984 Dalat nuclear research reactor of nominal power of 500 kW has been reconstructed and put into operation. This reactor is unique in Vietnam and has become an important scientific tool for development of nuclear techniques and radioisotope applications for socio-economic progress. Thanks to this important scientific tool, a variety of radioisotopes for medicine and industry applications as well as for scientific research has been produced. Utilization of the Dalat research reactor for radioisotope production is also summarized in this paper

  12. Applications of radioisotopes in industry and healthcare in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Dien, N.N.; Quang, N.H. [Nucealr Research Institute, Dalat, (Viet Nam)

    1997-10-01

    Nowadays, in Vietnam radioisotopes have been used very widely in various socio-economic branches, especially in industry and healthcare. Applications of radioisotopes have significant meaning in economic development, people health protection, as well as in scientific research. In this paper, the present status and main applications of radiation and radioactive isotopes in industry and healthcare in Vietnam are reported. In order to control and monitor industrial processes, nucleonic control systems and radioactive tracer techniques have been utilized. Actually, sealed source applications are popular in Vietnam industry. A number of nuclear control devices and gauges have been used in the various industrial factories, such as liquid level gauges in steel industry, cement and beverage factories; density and moisture gauges in paper industry, etc. Tracer technique and sealed source applications have also been utilized in industrial production plants and in trouble-shooting in the petroleum industry. For medicine purposes, two departments of nuclear medicine were primarily established at the beginning of the 1970s. At the present time, a number of nuclear medicine departments have been set up and they have been equipped with advanced equipment. Main activities are focused on thyroid function studies, nuclear cardiology, brain scans, gastrointestinal studies, bone scans, etc. Since march 1984 Dalat nuclear research reactor of nominal power of 500 kW has been reconstructed and put into operation. This reactor is unique in Vietnam and has become an important scientific tool for development of nuclear techniques and radioisotope applications for socio-economic progress. Thanks to this important scientific tool, a variety of radioisotopes for medicine and industry applications as well as for scientific research has been produced. Utilization of the Dalat research reactor for radioisotope production is also summarized in this paper

  13. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning

    NARCIS (Netherlands)

    Deferm, Julie T.; Schreurs, Ruud; Baan, Frank; Bruggink, Robin; Merkx, Matthijs A. W.; Xi, Tong; Bergé, Stefaan J.; Maal, Thomas J. J.

    2017-01-01

    The purpose of this study was to assess the feasibility of 3D intraoral scanning for documentation of palatal soft tissue by evaluating the accuracy of shape, color, and curvature. Intraoral scans of ten participants' upper dentition and palate were acquired with the TRIOS® 3D intraoral scanner by

  14. Radioisotope applications for troubleshooting and optimizing industrial processes

    International Nuclear Information System (INIS)

    2002-03-01

    This brochure is intended to present the state-of -the-art in techniques for gamma scanning and neutron backscattering for troubleshooting inspection of columns, vessels, pipes, and tanks in many industrial processing sectors. It aims to provide not only an extensive description of what can be achieved by the application of radioisotope sealed sources but also sound experience-based guidance on all aspects of designing, carrying out and interpreting the results of industrial applications. Though it is written primarily for radioisotope practitioners, the brochure is also intended to function as an ambassador for the technology by promoting its benefits to governments, to the general public and to industrial end-users

  15. Transport of radioisotopes

    International Nuclear Information System (INIS)

    Aoki, Shigefumi

    1978-01-01

    Presently the amount of radioisotopes increased very much and the application spread to wide fields in Japan. Since facilities using radioisotopes are distributed to every place in the country, every transport means such as airplanes, automobiles, railways, ships and mail are employed. The problems in the transport of radioisotopes include too much difference in the recognition of criticality among the persons concerning the transportation and treatment, knowledges of shielding and energy difference in the types of radiation and handling of sealed and unsealed sources and the casks for transport. IAEA established the latest regulation on the package of radioisotopes in 1973, and in Japan, the related regulations will be revised according to the IAEA's regulation in near future. The present status in the inspection at the time of shipment, supervision, and the measures to the accidents are described for the transport means of airplanes, ships and automobiles. Finally, concerning the insurance for cargo, the objects of the insurance for radioisotopes include either the radioisotopes contained in casks for transportation or radioisotopes only. Generally, radioisotopes are accepted in all-risk condition including casks and limited to the useful radioisotopes for peaceful use. (Wakatsuki, Y

  16. US Department of Energy radioisotope customers with summary of radioisotope shipments, FY 1988

    International Nuclear Information System (INIS)

    Van Houten, N.C.

    1989-06-01

    Pacific Northwest Laboratory (PNL) prepared this edition of the radioisotope customer list at the request of the Office of Health and Environmental Research (ER-73), Office of Energy Research, US Department of Energy (DOE). This is the 25th report in a series dating from 1964. This report covers DOE radioisotope sales and distribution activities by its facilities to domestic, foreign and other DOE facilities for FY 1988. The report is divided into five sections: radioisotope suppliers, facility contacts, and radioisotopes or services supplied; a list of customers, suppliers, and radioisotopes purchased; a list of radioisotopes purchased cross-referenced to customer numbers; geographic locations of radioisotope customers; and radioisotope sales and transfers -- FY 1988. Radioisotopes not previously reported in this series of reports were argon-37, arsenic-72, arsenic-73, bismuth-207, gadolinium-151, rhenium-188, rhodium-101, selenium-72, xenon-123 and zirconium-88. The total value of DOE radioisotope sales for FY 1988 was $11.1 million, an increase of 3% from FY 1987

  17. US Department of Energy radioisotope customers with summary of radioisotope shipments, FY 1988

    Energy Technology Data Exchange (ETDEWEB)

    Van Houten, N.C.

    1989-06-01

    Pacific Northwest Laboratory (PNL) prepared this edition of the radioisotope customer list at the request of the Office of Health and Environmental Research (ER-73), Office of Energy Research, US Department of Energy (DOE). This is the 25th report in a series dating from 1964. This report covers DOE radioisotope sales and distribution activities by its facilities to domestic, foreign and other DOE facilities for FY 1988. The report is divided into five sections: radioisotope suppliers, facility contacts, and radioisotopes or services supplied; a list of customers, suppliers, and radioisotopes purchased; a list of radioisotopes purchased cross-referenced to customer numbers; geographic locations of radioisotope customers; and radioisotope sales and transfers -- FY 1988. Radioisotopes not previously reported in this series of reports were argon-37, arsenic-72, arsenic-73, bismuth-207, gadolinium-151, rhenium-188, rhodium-101, selenium-72, xenon-123 and zirconium-88. The total value of DOE radioisotope sales for FY 1988 was $11.1 million, an increase of 3% from FY 1987.

  18. Radioisotope spleen scan in patients with splenic injury

    International Nuclear Information System (INIS)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-01-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established

  19. Radioisotope spleen scan in patients with splenic injury

    Energy Technology Data Exchange (ETDEWEB)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-09-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established.

  20. CLASP Middle School/High School Boys of Color Policy Scan and Information Gathering

    Science.gov (United States)

    Toldson, Ivory A.; Crowell, Candice

    2012-01-01

    The purpose of this project is to provide an analysis of policy issues affecting middle school and high school-aged boys and young men of color in the areas of education, health, and pathways to employment. This policy scan and subsequent recommendations will provide valuable background knowledge to inform the future direction of policy efforts…

  1. Evaluation of the vascular state of hepatic tumor with radioisotope angiography and blood pool scintigraphies (early and delayed)

    International Nuclear Information System (INIS)

    Aburano, Tamio; Tonami, Norihisa; Hisada, Kinichi

    1976-01-01

    Combined radioisotope examinations of hepatic tumors have been performed using α 1 -fetoprotein radioimmunoassay, radioisotope angiography of the liver, and some tumor positive imaging scintigraphies. However, with these methods, it is frequently impossible to differentiate metastatic cancers from benign focal lesions. Radioisotope angiography of the liver, and both early (5 min later)- and delayed (4 hours later) blood pool scintigraphies of the liver were done continuously after 10mCi of sup(99m)Tc-albumin intravenous injection, in cases of clearcut focal lesions on sup(99m)Tc-colloid liver scan. The relationships among these findings were examined. Four of seven cases with hepatoma and two of nine cases with metastatic cancer which had showed hypervascular findings on radioisotope angiogram showed clear blood pool activities in the area of focal defects on sup(99m)Tc-colloid scan although less than liver. On the other hand, none of hypovascular tumors on radioisotope angiogram showed blood pool activities. However, four hours later, in most malignant lesions, the lesion to liver activity ratio calculated from data processing system showed a much higher value than the ratio obtained 5 min later after injection, although two cases with benign focal lesions did not show such sequential change. The sequential evaluation of the vascular state of a hepatic tumor using radioisotope angiography and early-and delayed blood pool scintigraphies was supposed to be extremely useful for the elucidation of the nature of focal hepatic lesions on sup(99m)Tc-colloid scan, especially in differentiating hypovascular malignant- and benign lesions. (auth.)

  2. Radioisotopes production and applications

    International Nuclear Information System (INIS)

    Dash, Ashutosh

    2015-01-01

    Application of radioisotopes for both medical and industrial applications constitutes one of the most important peaceful uses of atomic energy. The striking diffusion and the exciting perspective of radioisotope for a plethora of medical and industrial applications are mainly attributable to the penetrating and ionization properties of radiation emanating from radioisotopes. The revolutionary medical applications of radioisotopes for the diagnosis and treatment of a multitude of diseases are causing a rapid expansion of the nuclear medicine field. While the industrial uses of radioisotopes are not expanding as quickly, also require large amounts of radioisotopes. Production of radioisotopes is not only the first step, but also the most crucial for the success as well as sustainable growth of radioisotope applications. With the rapid growth and expanding areas of applications, the demands for isotopes have increased several folds. A number of radioisotopes of different physical half-life, energy of the particle or gamma emission, specific activity and chemistry are now regularly produced both at commercial centers as well as at selected nuclear science research institutes utilizing reactors and cyclotrons to meet the ever growing need

  3. Mathematical models for correction of images, obtained at radioisotope scan

    International Nuclear Information System (INIS)

    Glaz, A.; Lubans, A.

    2002-01-01

    The images, which obtained at radioisotope scintigraphy, contain distortions. Distortions appear as a result of absorption of radiation by patient's body's tissues. Two mathematical models for reducing of such distortions are proposed. Image obtained by only one gamma camera is used in the first mathematical model. Unfortunately, this model allows processing of the images only in case, when it can be assumed, that the investigated organ has a symmetric form. The images obtained by two gamma cameras are used in the second model. It gives possibility to assume that the investigated organ has non-symmetric form and to acquire more precise results. (authors)

  4. Study of acute renal insufficiency and chronic renal insufficiency using radioisotopes

    International Nuclear Information System (INIS)

    Raynaud, C.

    1976-01-01

    Radioisotopic renal function tests are of assistance to diagnose and follow-up the course of renal insufficiency. The radioisotopic renogram is useful in assessing the response to therapy of child obstructive uropathies and evaluating renal transplant function. The renal scan is helpful, in an emergency service, to differenciate chronic renal insufficiency from acute renal insufficiency. Hg renal uptake test provides informations on physiopathological problems. Among them, the following problems are emphasized: evolution of a nonfunctioning kidney, control of the success of a reparative surgery and of bilateral obstructive uropathies with unilateral symptoms [fr

  5. Nanocluster metal films as thermoelectric material for radioisotope mini battery unit

    International Nuclear Information System (INIS)

    Borisyuk, P.V.; Krasavin, A.V.; Tkalya, E.V.; Lebedinskii, Yu.Yu.; Vasiliev, O.S.; Yakovlev, V.P.; Kozlova, T.I.; Fetisov, V.V.

    2016-01-01

    The paper is devoted to studying the thermoelectric and structural properties of films based on metal nanoclusters (Au, Pd, Pt). The experimental results of the study of single nanoclusters’ tunneling conductance obtained with scanning tunneling spectroscopy are presented. The obtained data allowed us to evaluate the thermoelectric power of thin film consisting of densely packed individual nanoclusters. It is shown that such thin films can operate as highly efficient thermoelectric materials. A scheme of miniature thermoelectric radioisotope power source based on the thorium-228 isotope is proposed. The efficiency of the radioisotope battery using thermoelectric converters based on nanocluster metal films is shown to reach values up to 1.3%. The estimated characteristics of the device are comparable with the parameters of up-to-date radioisotope batteries based on nickel-63.

  6. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1986

    International Nuclear Information System (INIS)

    Lamar, D.A.

    1988-01-01

    Data were collected and compiled on radioisotopes produced and sold by Department of Energy (DOE) facilities, and on services rendered by DOE facilities. Compiled data were published and distributed in the document list of DOE Radioisotope Customers with Summary of Radioisotope Shipments, FY 1986, PNL-6361, October 1987. The DOE facilities that supplied information for the compilation were Argonne National Laboratory, Brookhaven National Laboratory, Hanford Engineering Development Laboratory, Idaho National Engineering Laboratory, Los Alamos National Laboratory, Oak Ridge National Laboratory, Pacific Northwest Laboratory, Savannah River Plant, and UNC Nuclear Industries, Inc. (Hanford). The data provided were reported in several different ways: (1) a list of radioisotopes and services provided by each facility; (2) a list of radioisotope customers, the supplying DOE facility, and the radioisotope or service provided to each customer; and (3) a list of the quantity and value of each radioisotope or service sold by each DOE facility. The sales information covered foreign customers, domestic private customers, and domestic DOE customers

  7. Simultaneous detection and removal of radioisotopes with modified alginate beads containing an azo-based probe using RGB coordinates

    International Nuclear Information System (INIS)

    Jo, Ara; Jang, Geunseok; Namgung, Ho; Kim, Choongho; Kim, Daigeun; Kim, Yujun; Kim, Jongho; Lee, Taek Seung

    2015-01-01

    Highlights: • Modified alginate with azo-based probe (ABO) was synthesized by a reaction between sodium alginate and azo-based probe (BO2). • BO2 was found to be a good probe molecule for radioisotopes using colorimetric analysis. • Detection of Co 2+ and Sr 2+ was mainly carried out via interaction between BO2 and metal ions. • Simultaneous removal of radioisotopes was assessed by the ion-exchange of carboxylate groups in sodium alginate. • The alginate beads with dual functions of detection and removal of metal ions are successfully accomplished. - Abstract: We prepared alginate beads that were modified with an azo-based probe molecule to monitor simultaneously the removal (by alginate) and probing (by the azo-probe molecule) of radioisotopes such as cobalt, strontium, and cesium ions. As an azo-probe molecule, Basic Orange 2 (BO2) was immobilized to the alginate bead. The BO2 in aqueous solution exhibited a slight red shift in absorption with a change in color from orange to dark orange upon addition of cobalt and strontium ions. In contrast, the color of BO2 did not change upon exposure to cesium ions. Thus, the covalently embedded BO2 in alginate beads could adsorb cobalt and strontium ions resulting in recognizable color change of the beads, which was induced by the formation of a complex between BO2 and metal ions. The color changes of the beads in the presence of metal ions were determined quantitatively using RGB color coordinate values. In addition to effectively removing metal ions, the colorimetric coordinate method provides a convenient and simple sensing technique for naked-eye metal ion detection.

  8. Quantitative assessment of salivary gland function by radioisotopic scanning in a randomized trial of pilocarpine for prevention of radiation Induced Xerostomia

    International Nuclear Information System (INIS)

    Fard-Esfahani, A.; Modarress-Mosalla, M.; Haddad, P.; Eftekhari, M.; Saghari, M.

    2001-01-01

    Radioisotope scanning is the best method for objective assessment of salivary gland function. Thus, it was used in a randomized trial of concomitant pilocarpine for assessment of radiation-induced xerostomia, in addition to subjective evaluation by an approved questionnaire and objective standard xerostomia grading. Patients randomized in a placebo-controlled trial of pilocarpine concurrent with irradiation for prevention of radiation-induced xerostomia were evaluated by salivary gland scintigraphy immediately before and 6 months after the end of head and neck radiotherapy. Salivary gland function was measured by ejection fraction (E F) of Technetium-99 m pertechnetate. The mean values for pre-and post-radiotherapy scans were calculated and compared. Also post-radiotherapy scan findings in the two groups of pilocarpine and placebo were compared using the Student's t-test. In addition, comparison was made between the scan results and the subjective findings and objective grading s.Twenty patients underwent the pre-radiotherapy salivary scintigraphy, and also 20 post-radiotherapy scans were performed . Mean parotid E F was 60.85% in the pre-radiotherapy and 9.08% in the post-radiotherapy scans (p<0.01). The means for submandibular glands in the pre-and post-radiotherapy scans were 41% and 11.2%, respectively (p<0.01). Also the mean E F was 14.5% in the pilocarpine group and 3.65 in the placebo group for parotid glands (p=0.07) and 18.3% and 4.1% respectively for submandibular glands (p<0.05). The salivary scans confirmed the subjective and objective xerostomia findings. Salivary gland scintigraphy is a valuable method for evaluation of xerostomia after head and neck radiotherapy, quantitatively demonstrating the protective effect of pilocarpine compared to placebo on salivary glands

  9. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  10. Effect of target color and scanning geometry on terrestrial LiDAR point-cloud noise and plane fitting

    Science.gov (United States)

    Bolkas, Dimitrios; Martinez, Aaron

    2018-01-01

    Point-cloud coordinate information derived from terrestrial Light Detection And Ranging (LiDAR) is important for several applications in surveying and civil engineering. Plane fitting and segmentation of target-surfaces is an important step in several applications such as in the monitoring of structures. Reliable parametric modeling and segmentation relies on the underlying quality of the point-cloud. Therefore, understanding how point-cloud errors affect fitting of planes and segmentation is important. Point-cloud intensity, which accompanies the point-cloud data, often goes hand-in-hand with point-cloud noise. This study uses industrial particle boards painted with eight different colors (black, white, grey, red, green, blue, brown, and yellow) and two different sheens (flat and semi-gloss) to explore how noise and plane residuals vary with scanning geometry (i.e., distance and incidence angle) and target-color. Results show that darker colors, such as black and brown, can produce point clouds that are several times noisier than bright targets, such as white. In addition, semi-gloss targets manage to reduce noise in dark targets by about 2-3 times. The study of plane residuals with scanning geometry reveals that, in many of the cases tested, residuals decrease with increasing incidence angles, which can assist in understanding the distribution of plane residuals in a dataset. Finally, a scheme is developed to derive survey guidelines based on the data collected in this experiment. Three examples demonstrate that users should consider instrument specification, required precision of plane residuals, required point-spacing, target-color, and target-sheen, when selecting scanning locations. Outcomes of this study can aid users to select appropriate instrumentation and improve planning of terrestrial LiDAR data-acquisition.

  11. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1984

    International Nuclear Information System (INIS)

    Baker, D.A.

    1985-08-01

    This edition of the radioisotope customer list was prepared at the request of the Office of Health and Environmental Research (ER-73), Office of Energy Research, Department of Energy (DOE). This document describes radioisotope distribution from DOE facilities to private firms including foreign and other DOE facilities. The information is divided into five sections: (1) isotope suppliers, facility contacts, and isotopes or services supplied; (2) customers, suppliers, and isotopes purchased; (3) isotopes purchased cross-referenced with customer numbers; (4) geographic locations of radioisotope customers; and (5) radioisotope sales and transfers - FY 1984

  12. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1984

    Energy Technology Data Exchange (ETDEWEB)

    Baker, D.A.

    1985-08-01

    This edition of the radioisotope customer list was prepared at the request of the Office of Health and Environmental Research (ER-73), Office of Energy Research, Department of Energy (DOE). This document describes radioisotope distribution from DOE facilities to private firms including foreign and other DOE facilities. The information is divided into five sections: (1) isotope suppliers, facility contacts, and isotopes or services supplied; (2) customers, suppliers, and isotopes purchased; (3) isotopes purchased cross-referenced with customer numbers; (4) geographic locations of radioisotope customers; and (5) radioisotope sales and transfers - FY 1984.

  13. Radioisotope detection with accelerators

    International Nuclear Information System (INIS)

    Mast, T.S.; Muller, R.A.; Tans, P.P.

    1979-12-01

    High energy mass spectrometry is a new and very sensitive technique of measuring rare radioisotopes. This paper describes the techniques used to select and identify the individual radioisotope atoms in a sample and the status of the radioisotope measurements and their applications

  14. Reactor-produced therapeutic radioisotopes

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.

    2002-01-01

    The significant worldwide increase in therapeutic radioisotope applications in nuclear medicine, oncology and interventional cardiology requires the dependable production of sufficient levels of radioisotopes for these applications (Reba, 2000; J. Nucl. Med., 1998; Nuclear News, 1999; Adelstein and Manning, 1994). The issues associated with both accelerator- and reactor-production of therapeutic radioisotopes is important. Clinical applications of therapeutic radioisotopes include the use of both sealed sources and unsealed radiopharmaceutical sources. Targeted radiopharmaceutical agents include those for cancer therapy and palliation of bone pain from metastatic disease, ablation of bone marrow prior to stem cell transplantation, treatment modalities for mono and oligo- and polyarthritis, for cancer therapy (including brachytherapy) and for the inhibition of the hyperplastic response following coronary angioplasty and other interventional procedures (For example, see Volkert and Hoffman, 1999). Sealed sources involve the use of radiolabeled devices for cancer therapy (brachytherapy) and also for the inhibition of the hyperplasia which is often encountered after angioplasty, especially with the exponential increase in the use of coronary stents and stents for the peripheral vasculature and other anatomical applications. Since neutron-rich radioisotopes often decay by beta decay or decay to beta-emitting daughter radioisotopes which serve as the basis for radionuclide generator systems, reactors are expected to play an increasingly important role for the production of a large variety of therapeutic radioisotopes required for these and other developing therapeutic applications. Because of the importance of the availability of reactor-produced radioisotopes for these applications, an understanding of the contribution of neutron spectra for radioisotope production and determination of those cross sections which have not yet been established is important. This

  15. Application state of radioisotopes for medical use

    International Nuclear Information System (INIS)

    Nakajima, Tomoyoshi

    1979-01-01

    Application of unsealed radioisotopes as radiopharmaceuticals has been increasing year by year with the development of nuclear medicine. As for the radioisotopes for in vivo use which are internally administered and are detected by external scanning, the consumption of Tc-99 m drugs has increased rapidly. The sales of radiopharmaceuticals for in vivo use including 131 I, etc. amounted to four billion Yen in 1977. The consumption of the isotopes used in vitro for radioimmunoassay has made more rapid increase, and the sales of radiopharmaceuticals for in vitro use amounted to seven billion Yen in 1977. Radiopharmaceuticals have been used in 1,134 institutes all over Japan in 1978. 534 among them have applied radiopharmaceuticals to both in vivo and in vitro uses. Radioactive wastes have been increasing with the application of these unsealed radiopharmaceuticals, and their disposal method should be examined as there is a limit in their storage. (Kobatake, H.)

  16. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1985

    Energy Technology Data Exchange (ETDEWEB)

    Baker, D.A.

    1986-08-01

    This document describes radioisotope distribution from DOE facilities to private firms including foreign and other DOE facilities. The information is divided into five sections: (1) isotope suppliers, facility contacts, and isotopes or services supplied; (2) customers, suppliers, and isotopes purchased; (3) isotopes purchased cross-referenced with customer numbers; (4) geographic locations of radioisotope customers; and (5) radioisotope sales and transfer - FY 1985.

  17. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1985

    International Nuclear Information System (INIS)

    Baker, D.A.

    1986-08-01

    This document describes radioisotope distribution from DOE facilities to private firms including foreign and other DOE facilities. The information is divided into five sections: (1) isotope suppliers, facility contacts, and isotopes or services supplied; (2) customers, suppliers, and isotopes purchased; (3) isotopes purchased cross-referenced with customer numbers; (4) geographic locations of radioisotope customers; and (5) radioisotope sales and transfer - FY 1985

  18. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  19. Production and utilization of radioisotopes

    International Nuclear Information System (INIS)

    Sekine, Toshiaki; Matsuoka, Hiromitsu

    1999-01-01

    A plan of developing radioisotopes with a high power proton accelerator of the Neutron Science Project is presented. The status of production and utilization of radioisotopes in Japan is briefly discussed. The radioisotopes to be produced for biomedical use are discussed together with the facility for production of those radioisotopes and for research with the products. (author)

  20. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  1. Application of radioisotopes in entomology

    International Nuclear Information System (INIS)

    Saour, G.

    1995-01-01

    Radioisotope techniques are effective in entomology and studies on insects physiology. The study presents the use of radioisotopes in pest control programs: Methods of insects irradiation and the concept of biological half-life of the radioisotopes in comparison with physical half-life are explained. Main radioisotopes used in entomology are: 3 H, 14 Ca, 32 P, 35 S, 38 Cl. Other radioisotopes contributing to studies on insects are: 198 Au, 134 Cs, 131 I, 86 Rb, 65 Zn, 59 Fe, 45 Ca, 24 Na, 22 Na. Radiation doses specific to each radioisotopes are given in tables. As an example of the application of radioisotopes in pest control: the determination of insects population density by means of releasing irradiated male insects than chasing them; studying of reproduction activity of Agrotis ipsilon; studying of egg laying of Heliocoverpa armigera moth. 15 refs. 2 figs. 2 tabs

  2. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1986

    International Nuclear Information System (INIS)

    Lamar, D.A.

    1987-10-01

    This document describes radioisotope distribution from DOE facilities to private firms including foreign and other DOE facilities. The information is divided into five sections: (1)isotope suppliers, facility contact, and isotopes or services supplied; (2) customers, suppliers, and isotopes purchased; (3) isotopes purchased cross-referenced with customer numbers; (4) geographic locations of radioisotope customers; and (5) radioisotope sales and transfers for fiscal year 1986

  3. Application of radioisotopes in entomology

    Energy Technology Data Exchange (ETDEWEB)

    Saour, G [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Agriculture

    1995-10-01

    Radioisotope techniques are effective in entomology and studies on insects physiology. The study presents the use of radioisotopes in pest control programs: Methods of insects irradiation and the concept of biological half-life of the radioisotopes in comparison with physical half-life are explained. Main radioisotopes used in entomology are:{sup 3}H, {sup 14}Ca, {sup 32}P, {sup 35}S, {sup 38}Cl. Other radioisotopes contributing to studies on insects are: {sup 198}Au, {sup 134}Cs, {sup 131}I, {sup 86}Rb, {sup 65}Zn, {sup 59}Fe, {sup 45}Ca, {sup 24}Na, {sup 22}Na. Radiation doses specific to each radioisotopes are given in tables. As an example of the application of radioisotopes in pest control: the determination of insects population density by means of releasing irradiated male insects than chasing them; studying of reproduction activity of Agrotis ipsilon; studying of egg laying of Heliocoverpa armigera moth. 15 refs. 2 figs. 2 tabs.

  4. Applications of radioisotopes in medicine

    International Nuclear Information System (INIS)

    Sivaprasad, N.

    2012-01-01

    The application of radioisotopes in medicine is many folds. They can be classified into two main groups. (a) The radioisotope tagged labeled compounds suitable for safe administration in the body for diagnosis of various diseases of vital organs such as brain, kidney, thyroid etc and for treatment known as radiotherapy (b) The sealed source of radioisotopes for utilizing the radiation emitted from the radioisotope for treatment, particularly for radiation therapy of cancer. The former application of radioisotope in the field of medicine has led to the formation of special branch of medicine termed Nuclear Medicine - the branch of medicine deals with the use of radioisotope in the from of radiopharmaceuticals for investigation, diagnosis and treatment of diseases. Radioisotopes in the form of radiolabelled compound and bio-chemicals that are pharmaceutically and radiologically safe for administration in the body for diagnosis and treatment are called radiopharmaceuticals. The radiopharmaceuticals are the results of world-wide effort to bring nuclear energy in a tangible form for diagnosis and treatment. Radioisotopes as radiopharmaceuticals thus constitute one of the key requirements for nuclear medicine investigation and radiotherapy. In the case of sealed radioisotope source the radiation emitted by the radioactive source is utilized for the treatment and this mode of treatment is called radiation therapy where no radioactive substance is administrated into the body. This does not form the part of nuclear medicine

  5. Radioisotope battery for particular application

    International Nuclear Information System (INIS)

    Shen Tianjian; Liang Daihua; Cai Jianhua; Dai Zhimin; Xia Huihao; Wang Jianhua; Sun Sen; Yu Guojun; Wang Xiao; Wang Dongxing; Liu Xin

    2010-01-01

    Radioisotope battery, as a new type of power source, was developed in 1960s. It is advantageous in terms of long working life, high reliability, flexibility to rugged environment, maintenance free, and high capacity rate, hence its unique applications in space, isolated terrestrial or ocean spots, deep waters, and medicine. In this paper, we analysz the primary performances and classification of radioisotope thermoelectric generator, as well as characteristic, basic principle,and structure of radioisotope thermoelectric generator (RTG), which is the most popular in application of radioisotope battery in space, undersea, terrestrial and medicine. A prospect for development and application of radioisotope battery in the 21 st century is given, too. (authors)

  6. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1979

    International Nuclear Information System (INIS)

    Burlison, J.S.

    1980-06-01

    The fifteenth edition of the radioisotope customer list was prepared at the request of the Division of Financial Services, Office of the Assistant Secretary for Environment, Department of Energy (DOE). This document lists DOE's radioisotope production and distribution activities by its facilities at Argonne National Laboratory; Pacific Northwest Laboratory; Brookhaven National Laboratory; Hanford Engineering Development Laboratory; Idaho Operations Office; Los Alamos Scientific Laboratory; Mound Facility; Oak Ridge National Laboratory; Rocky Flats Area Office; Savannah River Laboratory; and UNC Nuclear Industries, Inc. The information is divided into five sections: Isotope suppliers, facility, contracts and isotopes or services supplied; alphabetical list of customers, and isotopes purchased; alphabetical list of isotopes cross-referenced to customer numbers; geographical location of radioisotope customers; and radioisotope sales and transfers-FY 1979

  7. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1981

    International Nuclear Information System (INIS)

    Burlison, J.S.

    1982-09-01

    The seventeenth edition of the radioisotope customer list was prepared at the request of the Office of Health and Environmental Research, Office of Energy Research, Department of Energy (DOE). This document lists DOE's radioisotope production and distribution activities by its facilities at Argonne National Laboratory: Pacific Northwest Laboratory; Brookhaven National Laboratory; Hanford Engineering Development Laboratory; Idaho Operations Office; Los Alamos Scientific Laboratory; Mound Facility; Oak Ridge National Laboratory; Savannah River Laboratory; and UNC Nuclear Industries, Inc. The information is divided into five sections: (1) isotope suppliers, facility, contracts and isotopes or services supplied; (2) alphabetical list of customers, and isotopes purchased; (3) alphabetical list of isotopes cross-referenced to customer numbers; (4) geographical location of radioisotope customers; and (5) radioisotope sales and transfers-FY 1980

  8. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1980

    International Nuclear Information System (INIS)

    Burlison, J.S.

    1981-08-01

    The sixteenth edition of the radioisotope customer list was prepared at the request of the Office of Health and Environmental Research, Office of energy Research, Department of Energy (DOE). This document lists DOE's radioisotope production and distribution activities by its facilities at Argonne National Laboratory; Pacific Northwest Laboratory; Brookhaven National Laboraory; Hanford Engineering Development Laboratory; Idaho Operations Office; Los Alamos Scientific Laboratory; Mound Facility; Oak Ridge National Laboratory; Savannah River Laboratory; and UNC Nuclear Industries, Inc. The information is divided into five sections: (1) isotope suppliers, facility, contracts and isotopes or services supplied; (2) alphabetical list of customers, and isotopes purchased; (3) alphabetical list of isotopes cross-referenced to customer numbers; (4) geographical location of radioisotope customers; and (5) radioisotope sales and transfers-FY 1980

  9. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  10. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  11. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1983

    International Nuclear Information System (INIS)

    Baker, D.A.

    1984-08-01

    This document lists DOE's radioisotope production and distribution activities by its facilities at Argonne National Laboratory; Pacific Northwest Laboratory; Idaho Operations Office; Los Alamos National Laboratory; Oak Ridge National Laboratory; Savannah River Plant; and UNC Nuclear Industries, Inc. The information is divided into five sections: isotope suppliers, facility contacts, and isotopes or services supplied; lists of customers, suppliers and isotopes purchased; list of isotopes purchased cross-referenced to customer codes; geographic locations of radioisotope customers; and radioisotope sales and transfers - FY 1983

  12. List of DOE radioisotope customers with summary of radioisotope shipments, FY 1982

    International Nuclear Information System (INIS)

    Richards, M.P.

    1983-08-01

    The radioisotope production and distribution activities by facilities at Argonne National Laboratory, Pacific Northwest Laboratory, Brookhaven National Laboratory, Hanford Engineering Development Laboratory, Idaho Operations Office, Los Alamos Scientific Laboratory, Oak Ridge National Laboratory, Savannah River Laboratory, and UNC Nuclear Industries, Inc. are listed. The information is divided into five sections: isotope suppliers, facility, contacts, and isotopes or services supplied; alphabetical list of customers, and isotopes purchased; alphabetical list of isotopes cross-referenced to customs numbers; geographical location of radioisotope customers; and radioisotope sales and transfers-FY 1982

  13. Manual for reactor produced radioisotopes

    International Nuclear Information System (INIS)

    2003-01-01

    Radioisotopes find extensive applications in several fields including medicine, industry, agriculture and research. Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programmes. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. Specifications for final products and testing procedures for ensuring quality are also an essential part of a radioisotope production programme. The International Atomic Energy Agency (IAEA) has compiled and published such information before for the benefit of laboratories of Member States. The first compilation, entitled Manual of Radioisotope Production, was published in 1966 (Technical Reports Series No. 63). A more elaborate and comprehensive compilation, entitled Radioisotope Production and Quality Control, was published in 1971 (Technical Reports Series No. 128). Both served as useful reference sources for scientists working in radioisotope production worldwide. The 1971 publication has been out of print for quite some time. The IAEA convened a consultants meeting to consider the need for compiling an updated manual. The consultants recommended the publication of an updated manual taking the following into consideration: significant changes have taken place since 1971 in many aspects of radioisotope production; many radioisotopes have been newly introduced while many others have become gradually obsolete; considerable experience and knowledge have been gained in production of important radioisotopes over the years, which can be preserved through compilation of the manual; there is still a need for a comprehensive manual on radioisotope production methods for new entrants to the field, and as a reference. It was also felt that updating all the subjects covered in the 1971 manual at a time may not be practical considering the

  14. Scanning laser densitometry and color perimetry demonstrate reduced photopigment density and sensitivity in two patients with retinal degeneration.

    Science.gov (United States)

    Tornow, R P; Stilling, R; Zrenner, E

    1999-10-01

    To test the feasibility of scanning laser densitometry with a modified Rodenstock scanning laser ophthalmoscope (SLO) to measure the rod and cone photopigment distribution in patients with retinal diseases. Scanning laser densitometry was performed using a modified Rodenstock scanning laser ophthalmoscope. The distribution of the photopigments was calculated from dark adapted and bleached images taken with the 514 nm laser of the SLO. This wavelength is absorbed by rod and cone photopigments. Discrimination is possible due to their different spatial distribution. Additionally, to measure retinal sensitivity profiles, dark adapted two color static perimetry with a Tübinger manual perimeter was performed along the horizontal meridian with 1 degree spacing. A patient with retinitis pigmentosa had slightly reduced photopigment density within the central +/- 5 degrees but no detectable photopigment for eccentricities beyond 5 degrees. A patient with cone dystrophy had nearly normal pigment density beyond +/- 5 degrees, but considerably reduced photopigment density within the central +/- 5 degrees. Within the central +/- 5 degrees, the patient with retinitis pigmentosa had normal sensitivity for the red stimulus and reduced sensitivity for the green stimulus. There was no measurable function beyond 7 degrees. The patient with cone dystrophy had normal sensitivity for the green stimulus outside the foveal center and reduced sensitivity for the red stimulus at the foveal center. The results of color perimetry for this patient with a central scotoma were probably influenced by eccentric fixation. Scanning laser densitometry with a modified Rodenstock SLO is a useful method to assess the human photopigment distribution. Densitometry results were confirmed by dark adapted two color static perimetry. Photopigment distribution and retinal sensitivity profiles can be measured with high spatial resolution. This may help to measure exactly the temporal development of retinal

  15. Application and benefits to industry of radioisotope tracer techniques - an overview

    International Nuclear Information System (INIS)

    Hills, A.E.

    2002-01-01

    Radioisotopes continue to play an important role in better management of natural resources and industrial processes. The success of radioisotope applications is primarily to the ability, conferred by the unique properties of radioactive materials, to collect data, which cannot be obtained by other investigative techniques. Radioisotope-based industrial tracer techniques that have stood the test in their own right are described briefly and certain of the economic and process efficiency impacts are highlighted. The financial and other benefits of this technology, especially in Petrochemical sector have been amply demonstrated and accepted. Typical techniques employed are: Gamma ray scanning of distillation columns, leak testing of heat exchangers, deposit and blockage detection in pipe lines, homogeneous mixing, flow rate measurements and liquid interface measurements. The financial benefits by these techniques are widely accepted to exceed the cost of equipment and studies by several folds. Based on retrospective analysis of the data, it is found that an average cost-benefit ratio of 1:20 in many applications is reasonably representative. (Author)

  16. Radioisotope handling facilities and automation of radioisotope production

    International Nuclear Information System (INIS)

    2004-12-01

    If a survey is made of the advances in radioisotope handling facilities, as well as the technical conditions and equipment used for radioisotope production, it can be observed that no fundamental changes in the design principles and technical conditions of conventional manufacture have happened over the last several years. Recent developments are mainly based on previous experience aimed at providing safer and more reliable operations, more sophisticated maintenance technology and radioactive waste disposal. In addition to the above observation, significant improvements have been made in the production conditions of radioisotopes intended for medical use, by establishing aseptic conditions with clean areas and isolators, as well as by introducing quality assurance as governing principle in the production of pharmaceutical grade radioactive products. Requirements of the good manufacturing practice (GMP) are increasingly complied with by improving the technical and organizational conditions, as well as data registration and documentation. Technical conditions required for the aseptic production of pharmaceuticals and those required for radioactive materials conflicting in some aspects are because of the contrasting contamination mechanisms and due consideration of the radiation safety. These can be resolved by combining protection methods developed for pharmaceuticals and radioactive materials, with the necessary compromise in some cases. Automation serves to decrease the radiation dose to the operator and environment as well as to ensure more reliable and precise radiochemical processing. Automation has mainly been introduced in the production of sealed sources and PET radiopharmaceuticals. PC controlled technologies ensure high reliability for the production and product quality, whilst providing automatic data acquisition and registration required by quality assurance. PC control is also useful in the operation of measuring instruments and in devices used for

  17. Radioisotope Power Sources

    International Nuclear Information System (INIS)

    Culwell, J. P.

    1963-01-01

    The radioisotope power programme of the US Atomic Energy Commission has brought forth a whole new technology of the use of radioisotopes as energy sources in electric power generators. Radioisotope power systems are particularly suited for remote applications where long-lived, compact, reliable power is needed. Able to perform satisfactorily under extreme environmental conditions of temperature, sunlight and electromagnetic radiations, these ''atomic batteries'' are attractive power sources for remote data collecting devices, monitoring systems, satellites and other space missions. Radioisotopes used as fuels generally are either alpha or beta emitters. Alpha emitters are the preferable fuels but are more expensive and less available than beta fuels and are generally reserved for space applications. Beta fuels separated from reactor fission wastes are being used exclusively in land and sea applications at the present. It can be expected, however, that beta emitters such as stiontium-90 eventually will be used in space. Development work is being carried out on generators which will use mixed fission products as fuel. This fuel will be less expensive than the pure radioisotopes since the costs of isotope separation and purification are eliminated. Prototype thermoelectric generators, fuelled with strontium-90 and caesium-137, are now in operation or being developed for use in weather stations, marine navigation aids and deep sea monitoring devices. A plutonium-238 thermoelectric generator is in orbit operating as electric power source in a US Navy TRANSIT satellite. Generators are under development for use on US National Aeronautics and Space Administration missions. The large quantities of radioactivity involved in radioisotope power sources require that special attention be given to safety aspects of the units. Rigid safety requirements have been established and extensive tests have been conducted to insure that these systems can be employed without creating undue

  18. Present status of OAP radioisotope production

    International Nuclear Information System (INIS)

    Charoen, Sakda

    2006-01-01

    Radioisotope Production Program (RP), Office of Atoms for Peace (OAP) is a non-profit government organization which responsible for research development and service of radioisotopes. Several research works on radioisotope production have been carried on at OAP. The radioisotope products of successful R and D have been routinely produced to supply for medical, agriculture and research application. The main products are 131 I (solution and capsule), 131 I-MIBG, 131 I-Hippuran, 153 Sm-EDTMP, 153 Sm-HA, and 99m Tc-radiopharmaceutical kits to serve local users. Radioisotopes are very beneficial for science and human welfare so as almost of our products and services are mainly utilized for medical purpose for both diagnosis and therapy. OAP has a policy to serve and response to that community by providing radioisotopes and services with high quality but reasonable price. This policy will give the opportunity to the community to utilize these radioisotopes for their healthcare. (author)

  19. Bone radioisotope scanning: usefulness in the evaluation and observation of patients with breast cancer in clinical stage II, III, IV

    International Nuclear Information System (INIS)

    Cano P, R.A.

    1995-01-01

    The clinical records of 420 patients with diagnosis of breast cancer well documented by the pathological anatomy in clinical stage II, III and IV were reviewed. In each one of them has been done at least a bone scanning during the diagnosis. In 52 cases carried out sericeous dosages of CA 15-3 and in some cases it was necessary to administer Samarium-153 EDTMP as palliative therapy of bone pain. The presence of secondary gamma-graphic focuses was 0/84 cases (0%) in clinical stage II, 54/265 cases (20%) in III and 41/91 cases (45%) in IV. The one focus appeared in 6.7% of the cases. In 7 of the 52 cases that received sericeous dosages of CA 15-3 were detected secondary osseous lesions, and 5 of them presented a marker elevation. The bone scanning has shown in many cases the presence of getters focuses in singular places of skeleton, urinary excretory system or mammary tissue. The gamma rays from Sm-153 allowed us to get some appropriate basal views post-therapy of the secondary lesions. The results show that the great incidence of secondary lesions in the skeleton occurred in cases of stages III and IV unlike other countries. The serial repetition of the radioisotope scanning. The presence of one focus in the skeleton of a patient with a well-known neoplasia makes us to do a careful evaluation of the focus nature. The presence of tracer accumulation in the kidney, ureter and bladder allows us to infer the pathology of excretory system that is the first evidence of its presence in many cases. (author). 71 refs., 7 figs., 6 tabs

  20. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  1. Application of radioisotopes in pharmaceutical research

    International Nuclear Information System (INIS)

    Khujaev, S.

    2004-01-01

    Full text: To use of radioisotopes in the processes of receiving radiopharmaceutical diagnostic means it is widely know [1]. Radioactivity labeled chemical compounds, pharmacological kinetics of which allows one solving a concrete diagnostic problem in an organism are used in radio pharmaceutics. In spite of this choice of the radioisotope, possessing the most favorable nuclei-physical characteristics for it to be detected and minimization of beam loadings, be of great importance. Development of a method of introduction of a radioisotope also has important value, as it is included into chemical structure of a radiopharmaceutical preparation. One more way of use of radioisotopes in pharmaceutics is their use as a radioactive mark at a stage of creation of a new medical product. And in this case, all those moments, which are listed above, take place. Preparations labeling by radioisotopes are used basically for their studying pharmacological kinetics. In Institute of nuclear physics AS RU, in recent years, works are done on studying pharmacological kinetics of some new medical products, which have been synthesized in the Tashkent pharmaceutical institute. These preparations are on the basis of microelements with a complex set of properties possessing expressed biological activity and have great value in pharmaceutical science of Republic of Uzbekistan. Reception of labeled compounds of all preparations was carried out by a method of introduction of a radioisotope at a stage of their synthesis. The work presents the results of researches on synthesis and study of pharmacological kinetics of radioactively labeled preparations - PIRACIN, labeled by radioisotope 69m Zn; FERAMED, labeled by radioisotope 59 Fe; COBAVIT, labeled by radioisotope 57 Co; VUC, labeled by radioisotope 57 Co

  2. Production of radioisotopes using accelerators

    International Nuclear Information System (INIS)

    Qaim, S.M.

    1990-01-01

    Accelerator produced radioisotopes find applications in many fields. Most of them are ideally suited for in-vivo studies of physiological functions. A brief review of various types of accelerators used for radioisotope production is given. The 'state of art' technology relevant to the production of radioisotopes is briefly discussed. Some of the recent advances in nuclear data measurements, target development, chemical processing and quality control are described. There appears to be a definite shift from multipurpose accelerators to dedicated machines, and greater emphasis is placed now on the production of radioisotopes with high radionuclidic purity by choosing a suitable nuclear reaction in a proper energy range. (author)

  3. Activity calculation of radioisotopes in HFETR

    International Nuclear Information System (INIS)

    Liu Shuiqing

    1996-12-01

    The activity calculating method and formulas of seven kinds of radioisotopes for High Flux Engineering Test REactor (HFETR) are given. The perturbation of targets to neutron fluence rate is considered while targets are put into the neutron fluence rate field of reactor core. All perturbing factors of seven kinds of radioisotopes being used in HFETR are presented. After considering the perturbation, the calculating accuracy of radioisotope activity has been raised 10%. The given method and formulas have ended the history of all activities estimated by experiences, except for that of 60 Co, in the radioisotope production of HFETR. The conclusions are also useful and instructive for the production of radioisotopes in HFETR. (8 tabs.)

  4. Radiation induced color in topaz crystals

    International Nuclear Information System (INIS)

    Castagnet, A.C.; Rocca, H.C.C.; Rostilato, M.E.C.M.

    1989-08-01

    The presence of defects and impurities in the crystal lattice alters the eletric field distribution within the crystal, allowing the electrons to occupy energy levels in the forbbiden band. Ionizing radiation supply the required energy to permit the electrons originaly bound to lattice atoms, to occupy effectively those intermediate levels, forming color centers. Dependig upon the nature and energy of the radiation, it is possible to produce defects in regions of the crystal, generating color centers. Based on these premises, a technique to induce color in originally colorless topaz, by using the IEA-R1 nuclear reactor, was developed at Engineering and Industrial Application Department (TE). Samples were irradiated inside iron capsules coated with cadmium foils. The iron, and principaly the cadmium, absorb the thermal neutrons that could activate crystal impurities generating long-lived radioisotopes. The epithermal neutrons that overpass the iron and cadmium barriers interact with the crystal atoms, causing lattice defects which give rise to color center, by subsequent ionization processes. The procedure used at TE induces permanent blue color, in natural colorless topaz. (author) [pt

  5. Medical radioisotopes for the next century

    International Nuclear Information System (INIS)

    Carr, S.W.

    1999-01-01

    Radioisotopes are widely used in medicine (Nuclear Medicine) for diagnosis, palliation and therapy of heart disease, cancer, muscoskeletal and neurological conditions. The radioisotopes used are both reactor and cyclotron produced. The utilisation is currently growing and is expected to continue to grow over the next 10-20 years. The combination of radioisotope and delivery vehicle can be designed to meet the intended end use. This paper will deal with the main approaches to the use of radioisotopes for Nuclear medicine ad future prospects for the area

  6. Radioisotopes in industry

    International Nuclear Information System (INIS)

    Popple, B.N.

    1977-01-01

    The author explains clearly what is radiography, enumerates four major factors in considering a practical source to use namely half-life, penetrating power, half value layer and specific activity and also the advantages and disadvantages in using isotopes. Common radioisotopes used in industrial radiography are iridium, cesium, cobalt and thulium. Main uses of the radioisotopes are for radiographic testing like welding castings, forgoings etc.; thickness, level or density measurement and tracing. (RTD)

  7. Role of radioisotopes in the study of insect pests

    International Nuclear Information System (INIS)

    Mansour, M.

    2013-01-01

    Although the use of nuclear techniques, particularly radioisotopes, in entomological research is less than a century old, the contribution of radioisotopes to the science of studying insects (Entomology) is indispensable. In fact, radioisotopes provided a very important and sometimes a unique tool for solving many research problems in entomology. This article discusses the most important and widely used applications of radioisotopes in studying insect pests. In particular, it concentrates on the subject of radioisotopes used in entomological research, methods of labeling insect with radioisotopes, half life of radioisotopes, and the role of radioisotopes in physiological, ecological, biological and behavioral studies of insects. (author)

  8. Design of radioisotope power systems facility

    International Nuclear Information System (INIS)

    Eschenbaum, R.C.; Wiemers, M.J.

    1991-01-01

    Radioisotope power systems currently produced for the U.S. Department of Energy Office of Special Applications by the Mound Laboratory at Miamisburg, Ohio, have been used in a variety of configurations by the Department of Defense and the National Aeronautics and Space Administration. A forecast of fugure radioisotope power systems requirements showed a need for an increased production rate beyond the capability of the existing Mound Laboratory. Westinghouse Hanford Company is modifying the Fuels and Materials Examination Facility on the Hanford Site near Richland, Washington, to install the new Radioisotope Power Systems Facility for assembling future radioisotope power systems. The facility is currently being prepared to assemble the radioisotope thermoelectric generators required by the National Aeronautics and Space Administration missions for Comet Rendezvous Asteroid Flyby in 1995 and Cassini, an investigation of Saturn and its moons, in 1996

  9. Radioisotope Power Supply, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Between 1998 and 2003, Hi-Z Technology developed and built a 40 mW radioisotope power supply (RPS) that used a 1 watt radioisotope heater unit (RHU) as the energy...

  10. Value of venous color flow duplex scan as initial screening test for geriatric inpatients with clinically suspected pulmonary embolism

    Directory of Open Access Journals (Sweden)

    Kreidy R

    2011-09-01

    Full Text Available Raghid Kreidy1, Elias Stephan2, Pascale Salameh3, Mirna Waked4 1Department of Vascular Surgery, Saint George Hospital, University Medical Center, University of Balamand, Beirut, Lebanon; 2Department of Geriatrics, Saint George Hospital, University Medical Center, University of Balamand, Beirut, Lebanon; 3Laboratory of Clinical and Epidemiological Research, Faculty of Pharmacy, Lebanese University, 4Department of Pulmonary Medicine, Saint George Hospital, University Medical Center, University of Balamand, Beirut, Lebanon Aim: The contribution of lower extremity venous duplex scan to the diagnostic strategy for pulmonary embolism has been demonstrated by many authors. However, the positive diagnostic value of this noninvasive test in clinically suspected pulmonary embolism is not very high (10%–18%. Since thromboembolic risks increase considerably in hospitalized patients with advanced age, this study aims to determine the importance of lower extremity venous color flow duplex scan in this particular subgroup of patients with clinically suspected pulmonary embolism. The effects of clinical presentation and risk factors on the results of duplex scan have been also studied. Methods: Between July 2007 and January 2010, 95 consecutive Lebanese geriatric ($60 years of age inpatients with clinically suspected pulmonary embolism assessed in an academic tertiary-care center for complete lower extremity venous color flow duplex scan were retrospectively reviewed. Age varied between 60 and 96 years (mean, 79.9 years. Forty patients were males and 55 females. Absence of compressibility was the most important criteria for detecting acute venous thrombosis. Results: Out of 95 patients, 33 patients (34.7% were diagnosed with recent deep venous thrombosis of lower extremities (14 proximal and 19 distal using complete venous ultrasound. Nine of these 33 patients (27.2% had a history of venous thromboembolism and eleven (33.3% presented with edema of lower

  11. Radioisotope detection and dating with accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Mast, T S; Muller, R A [California Univ., Berkeley (USA). Lawrence Berkeley Lab.

    1980-07-01

    The status of the new technique of high energy mass spectrometry is reviewed. This sensitive method of measuring isotope concentrations has been applied to the detection of rare radioisotopes used for age estimation. The techniques used to select and identify the individual radioisotope atoms in a sample are described and then the status of the radioisotope measurements and their applications is reviewed.

  12. Support housing for radioisotope generation

    International Nuclear Information System (INIS)

    Fries, B.A.

    1976-01-01

    A support housing for on-site radioisotope generation is disclosed in which the formation of a short-lived daughter radioisotope from its longer-lived parent features countercurrent batch flow of the eluting reagent interior of the housing. 6 claims, 4 drawing figures

  13. List of ERDA radioisotope (customers with summary of radioisotope shipments FY 1975

    International Nuclear Information System (INIS)

    Simmons, J.L.; Gano, S.R.

    1976-01-01

    The twelfth edition of the ERDA radioisotope customer list has been prepared at the request of the Division of Biomedical and Environmental Research. The purpose of this document is to list the FY 1975 commercial radioisotope production and distribution activities of USERDA facilities at Argonne National Laboratory, Battelle, Pacific Northwest Laboratories, Brookhaven National Laboratory, United Nuclear Inc., Idaho Operations Office, Hanford Engineering Development Laboratory, Mound Laboratory, Oak Ridge National Laboratory, and Savannah River Plant

  14. Radioisotope conveyor ash meter

    International Nuclear Information System (INIS)

    Savelov, V.D.

    1994-01-01

    Radioisotope conveyor ash meter realizes persistent measuring of ashiness of coal and products of its enrichment on the belt conveyor without contact. The principle of ash meter acting is based on functional dependence of the gamma radiation flows backscattering intensity of radioisotope sources from the ash volume content in the controlled fuel. Facility consists from the ashiness transducer and the processing and control device

  15. Modular Stirling Radioisotope Generator

    Science.gov (United States)

    Schmitz, Paul C.; Mason, Lee S.; Schifer, Nicholas A.

    2016-01-01

    High-efficiency radioisotope power generators will play an important role in future NASA space exploration missions. Stirling Radioisotope Generators (SRGs) have been identified as a candidate generator technology capable of providing mission designers with an efficient, high-specific-power electrical generator. SRGs high conversion efficiency has the potential to extend the limited Pu-238 supply when compared with current Radioisotope Thermoelectric Generators (RTGs). Due to budgetary constraints, the Advanced Stirling Radioisotope Generator (ASRG) was canceled in the fall of 2013. Over the past year a joint study by NASA and the Department of Energy (DOE) called the Nuclear Power Assessment Study (NPAS) recommended that Stirling technologies continue to be explored. During the mission studies of the NPAS, spare SRGs were sometimes required to meet mission power system reliability requirements. This led to an additional mass penalty and increased isotope consumption levied on certain SRG-based missions. In an attempt to remove the spare power system, a new generator architecture is considered, which could increase the reliability of a Stirling generator and provide a more fault-tolerant power system. This new generator called the Modular Stirling Radioisotope Generator (MSRG) employs multiple parallel Stirling convertor/controller strings, all of which share the heat from the General Purpose Heat Source (GPHS) modules. For this design, generators utilizing one to eight GPHS modules were analyzed, which provided about 50 to 450 W of direct current (DC) to the spacecraft, respectively. Four Stirling convertors are arranged around each GPHS module resulting in from 4 to 32 Stirling/controller strings. The convertors are balanced either individually or in pairs, and are radiatively coupled to the GPHS modules. Heat is rejected through the housing/radiator, which is similar in construction to the ASRG. Mass and power analysis for these systems indicate that specific

  16. The efficient importation and distribution of radioisotopes. Suggestions for the most economic importation of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-08-01

    In the course of their work in many Member States, IAEA technical assistance experts have sometimes encountered difficulties in connection with the importation of radioactive isotopes. In some countries they have been consulted as to the possible improvement of import procedures. The purpose of this publication is to summarize the experience that has been gained in the hope that it may be useful both to scientists who wish to import radioisotopes for their work and to public officials who are concerned with the administrative and financial aspects of the problem. This question is of considerable importance because many countries have only limited resources of scientific man-power and foreign exchange and hence it is essential, if these resources are to be utilized fully, that efficient importing procedures be established. Furthermore, the success or failure of technical assistance activities may depend on whether radioisotopes needed for the project can be efficiently imported. Although the data summarized in this publication are based mainly on the experience of medical users of radioisotopes, they are equally applicable to their uses in other fields such as agriculture and hydrology. This publication covers the subject of importation and distribution of radioisotopes, and concludes with a brief section on the domestic production of short-lived radioisotopes in research reactors.

  17. The efficient importation and distribution of radioisotopes. Suggestions for the most economic importation of radioisotopes

    International Nuclear Information System (INIS)

    1963-01-01

    In the course of their work in many Member States, IAEA technical assistance experts have sometimes encountered difficulties in connection with the importation of radioactive isotopes. In some countries they have been consulted as to the possible improvement of import procedures. The purpose of this publication is to summarize the experience that has been gained in the hope that it may be useful both to scientists who wish to import radioisotopes for their work and to public officials who are concerned with the administrative and financial aspects of the problem. This question is of considerable importance because many countries have only limited resources of scientific man-power and foreign exchange and hence it is essential, if these resources are to be utilized fully, that efficient importing procedures be established. Furthermore, the success or failure of technical assistance activities may depend on whether radioisotopes needed for the project can be efficiently imported. Although the data summarized in this publication are based mainly on the experience of medical users of radioisotopes, they are equally applicable to their uses in other fields such as agriculture and hydrology. This publication covers the subject of importation and distribution of radioisotopes, and concludes with a brief section on the domestic production of short-lived radioisotopes in research reactors

  18. Notification determining details of technical standards concerning transport of radioisotopes or goods contaminated by radioisotopes outside works or enterprises

    International Nuclear Information System (INIS)

    1981-01-01

    This rule is established under the provisions of the regulation for the execution of the law on the prevention of radiation injuries by radioisotopes. Terms are used in this rule for the same meanings as in the regulation. The concentration of radioisotopes to which the technical standards for transport outside enterprises are not applied is 0.002 micro-curie per gram. The radioisotopes which can be transported as L type transported goods are defined in detail, excluding explosive or spontaneously igniting radioisotopes. The quantity limit of radioisotopes which can be transported as A type transported goods is the values A 1 and A 2 defined in this rule. The permissible surface density defined by the Director General of the Science and Technology Agency are 1/100,000 micro-curie per cm 2 for the radioisotopes emitting alpha-ray, and 1/10,000 micro-curie per cm 2 for the radioisotopes which do not emit alpha-ray. The leak quantity of radioisotopes specified by the Director General is 1/1,000,000 of A 2 value for BM type transported goods and 1/1,000 of A 2 value for BU type goods. The test conditions for each type of transported goods, dangerous goods, the limit of the number of transported goods and signs are stipulated, respectively. Permissible exposure dose is 1.5 rem a year for persons other than radiation workers. (Okada, K.)

  19. Radioisotopic neutron transmission spectrometry: Quantitative analysis by using partial least-squares method

    International Nuclear Information System (INIS)

    Kim, Jong-Yun; Choi, Yong Suk; Park, Yong Joon; Jung, Sung-Hee

    2009-01-01

    Neutron spectrometry, based on the scattering of high energy fast neutrons from a radioisotope and slowing-down by the light hydrogen atoms, is a useful technique for non-destructive, quantitative measurement of hydrogen content because it has a large measuring volume, and is not affected by temperature, pressure, pH value and color. The most common choice for radioisotope neutron source is 252 Cf or 241 Am-Be. In this study, 252 Cf with a neutron flux of 6.3x10 6 n/s has been used as an attractive neutron source because of its high flux neutron and weak radioactivity. Pulse-height neutron spectra have been obtained by using in-house built radioisotopic neutron spectrometric system equipped with 3 He detector and multi-channel analyzer, including a neutron shield. As a preliminary study, polyethylene block (density of ∼0.947 g/cc and area of 40 cmx25 cm) was used for the determination of hydrogen content by using multivariate calibration models, depending on the thickness of the block. Compared with the results obtained from a simple linear calibration model, partial least-squares regression (PLSR) method offered a better performance in a quantitative data analysis. It also revealed that the PLSR method in a neutron spectrometric system can be promising in the real-time, online monitoring of the powder process to determine the content of any type of molecules containing hydrogen nuclei.

  20. Medical Radioisotopes Production Without A Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Van der Keur, H.

    2010-05-15

    This report is answering the key question: Is it possible to ban the use of research reactors for the production of medical radioisotopes? Chapter 2 offers a summarized overview on the history of nuclear medicine. Chapter 3 gives an overview of the basic principles and understandings of nuclear medicine. The production of radioisotopes and its use in radiopharmaceuticals as a tracer for imaging particular parts of the inside of the human body (diagnosis) or as an agent in radiotherapy. Chapter 4 lists the use of popular medical radioisotopes used in nuclear imaging techniques and radiotherapy. Chapter 5 analyses reactor-based radioisotopes that can be produced by particle accelerators on commercial scale, other alternatives and the advantages of the cyclotron. Chapter 6 gives an overview of recent developments and prospects in worldwide radioisotopes production. Chapter 7 presents discussion, conclusions and recommendations, and is answering the abovementioned key question of this report: Is it possible to ban the use of a nuclear reactor for the production of radiopharmaceuticals? Is a safe and secure production of radioisotopes possible?.

  1. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  2. List of ERDA radioisotope customers with summary of radioisotope shipments, FY 1976

    International Nuclear Information System (INIS)

    Simmons, J.L.

    1977-03-01

    The thirteenth edition of the ERDA radioisotope customer list has been prepared at the request of the Office of Program Coordination, Office of the Assistant Administrator. The purpose of the document is to list the FY 1976 commercial radioisotope production and distribution activities of ERDA facilities at Argonne National Laboratory, Battelle, Pacific Northwest Laboratories, Brookhaven National Laboratory, Hanford Engineering Development Laboratory, Idaho Operations Office, Los Alamos Scientific Laboratory, Mound Laboratory, Oak Ridge National Laboratory, Savannah River Laboratory, and United Nuclear Industries, Inc

  3. The safe handling of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1964-12-31

    A narrative account of a minor contamination accident in a laboratory is used to demonstrate the important role of radiation protection measures in radioisotope work and the necessity of giving proper regard to such measures. It is primarily directed towards the research scientists and medical workers using radioisotopes on a relatively small scale

  4. Manual of radioisotope production

    International Nuclear Information System (INIS)

    1966-01-01

    The Manual of Radioisotope Production has been compiled primarily to help small reactor establishments which need a modest programme of radioisotope production for local requirements. It is not comprehensive, but gives guidance on essential preliminary considerations and problems that may be met in the early stages of production. References are included as an aid to the reader who wishes to seek further in the extensive literature on the subject. In preparing the Manual, which is in two parts, the Agency consulted several Member States which already have long experience in radioisotope production. An attempt has been made to condense this experience, firstly, by setting out the technical and economic considerations which govern the planning and execution of an isotope programme and, secondly, by providing experimental details of isotope production processes. Part I covers topics common to all radioisotope processing, namely, laboratory design, handling and dispensing of radioactive solutions, quality control, measurement and radiological safety. Part II contains information on the fifteen radioisotopes in most common use. These are bromine-82, cobalt-58, chromium-51, copper-64, fluorine-18, gold-198, iodine-131, iron-59, magnesium-28, potassium-42, sodium-24, phosphorus-32, sulphur-35, yttrium-90 and zinc-65. Their nuclear properties are described, references to typical applications are given and published methods of production are reviewed; also included are descriptions in detail of the production processes used at several national atomic energy organizations. No attempt has been made to distinguish the best values for nuclear data or to comment on the relative merits of production processes. Each process is presented essentially as it was described by the contributor on the understanding that critical comparisons are not necessary for processes which have been well tried in practical production for many years. The information is presented as a guide to enable

  5. Industrial radioisotope economics. Findings of the study group

    International Nuclear Information System (INIS)

    1965-01-01

    Within twenty years of the availability of radioisotopes in quantity the use of these as tracers has been widely applied in scientific research and in industrial process and product control. Industry spends millions of dollars on these new techniques. Since the overall attitude of industry is to favour methods that involve rapid financial returns the economic benefits must be considerable. In promoting the peaceful uses of atomic energy, the IAEA is actively interested in the international exchange of experience in all applications of radioisotopes. This has been demonstrated by a number of scientific conferences where new results of direct importance to the industrial use of radioisotopes have been presented. In 1963 the IAEA also published literature survey on radioisotope applications described in the scientific literature up to 1960, classified according to industry. However, the available scientific literature was found insufficient to determine the extent of the use of radioisotopes and the economic benefits derived from it. Therefore, further fact-finding efforts were necessary. The IAEA thus decided to carry out an International Survey on the Use of Radioisotopes in Industry. In 1962 the IAEA's highly industrialized Member States Were invited to participate in the Survey; 25 declared their willingness to do so and in due course submitted their national reports. These included information on how radioisotopes were used by industry in each country and indicated the size and form of the economic advantages, primarily in terms of savings made by industry. The findings from the Survey were discussed at a Study Group Meeting on Radioisotope Economics, held in Vienna in March 1964. Forty participants from 22 countries were nominated for this Study Group. The program of the meeting was divided in three parts: (1) experience of the International Survey on the use of radioisotopes in industry; (2) present use of radioisotopes, technical and economic aspects; (3

  6. Antibody-radioisotope conjugates for tumor localization and treatment

    International Nuclear Information System (INIS)

    Larson, S.M.; Carrasquillo, J.A.

    1985-01-01

    In principle, anti-tumor antibodies can be used to carry radioactivity to tumors for in-vivo diagnosis and treatment of cancer. First, for diagnostic purposes, an antibody that targets a specific antigen (for example, the p97 antigen of human melanoma tumor), is labeled with a tracer amount of radioactivity. When this antibody-radioisotope conjugate is injected into the blood stream, the antibody carries the radioactivity throughout the body and in time, percolates through all the tissues of the body. Because the tumor has specific antigens to which the antibody can bind, the antibody conjugate progressively accumulates in the tumor. Using conventional nuclear medicine imaging equipment, the body of the patient is scanned for radioactivity content, and a map of the distribution of the radioactivity is displayed on photographic film. The tumor shows up as a dense area of radio-activity. These same antibody-radioisotope conjugates may be used for therapy of tumors, except that in this case large amounts of radioactivity are loaded on the antibody. After localization of the conjugate there is sufficient radiation deposited in the tumor of radiotherapy. The success of this approach in the clinic is determined in large measure by the concentration gradient that can be achieved between tissue antibody conjugate in tumor versus normal tissue

  7. Markets for reactor-produced non-fission radioisotopes

    International Nuclear Information System (INIS)

    Bennett, R.G.

    1995-01-01

    Current market segments for reactor produced radioisotopes are developed and reported from a review of current literature. Specific radioisotopes studied in is report are the primarily selected from those with major medical or industrial markets, or those expected to have strongly emerging markets. Relative market sizes are indicated. Special emphasis is given to those radioisotopes that are best matched to production in high flux reactors such as the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory or the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory. A general bibliography of medical and industrial radioisotope applications, trends, and historical notes is included

  8. Research trends in radioisotopes: a scientometric analysis

    International Nuclear Information System (INIS)

    Sagar, Anil; Kademani, B.S.; Bhanumurthy, K.; Ramamoorthy, N.

    2014-01-01

    Radioisotopes or radionuclides are radioactive forms of elements and are usually produced in research reactors and accelerators. They have wide ranging applications in healthcare, industry, food and agriculture, and environmental monitoring. Following over five decades of vast experience accumulated, radioisotope technology has developed to a high degree of sophistication and it is estimated that about 200 radioisotopes are in regular use. This paper attempts to highlight the publication status and growth of radioisotope research across the world and make quantitative and qualitative assessment by way of analyzing the following features of research output based on Web of Science database during the period 1993-2012. (author)

  9. Radioisotope techniques for problem-solving on refineries

    International Nuclear Information System (INIS)

    Charlton, J.S.; Webb, M.

    1994-01-01

    Increasingly, refineries worldwide are recognizing the value of radioisotope technology in studying the operation of on-line plant. Using case studies, this paper illustrates the versatility of radioisotope techniques in a wide range of investigations: the density-profiling of distillation columns; the investigation of leaks on feed/effluent exchangers; on-line flowrate measurement; underground leakage detection. The economic benefits deriving from radioisotope applications are indicated

  10. Radioisotope applications in industry and environment: Indian scenario

    International Nuclear Information System (INIS)

    Pant, H.J.

    2016-01-01

    Applications of radioisotopes and radiation technology in industry, medicine and agriculture form an important part of India's programme of using nuclear technology for societal benefits. Radioisotope production in India started on a modest scale soon after 1 MW APSARA reactor at Trombay, Mumbai became critical in 1956. The scope of activities expanded thereafter. With the commissioning of 40 MW CIRUS reactor in 1960, the setting up of modern radioisotope processing laboratories in late sixties and the production of cobalt-60 in power reactors in megacurie quantities in late seventies made India self-sufficient in radioisotope production. The radioisotope production received a major boost in 1985 with the commissioning of high flux 100 MW DHRUVA reactor, which provided opportunity to extend the range of radioisotopes available in the country both in quantity as well in specific activity. The CIRUS reactor has been shutdown in year 2010 and 1 MW APSARA reactor is presently being upgraded to 5 MW. Today, The DHRUVA reactor operating at its full capacity is being used for production of 100 different radioisotopes those are used in industry, agriculture and medicine. (author)

  11. Advanced Radioisotope Power Conversion Technology Research and Development

    Science.gov (United States)

    Wong, Wayne A.

    2004-01-01

    NASA's Radioisotope Power Conversion Technology program is developing next generation power conversion technologies that will enable future missions that have requirements that cannot be met by either the ubiquitous photovoltaic systems or by current Radioisotope Power System (RPS) technology. Performance goals of advanced radioisotope power systems include improvement over the state-of-practice General Purpose Heat Source/Radioisotope Thermoelectric Generator by providing significantly higher efficiency to reduce the number of radioisotope fuel modules, and increase specific power (watts/kilogram). Other Advanced RPS goals include safety, long-life, reliability, scalability, multi-mission capability, resistance to radiation, and minimal interference with the scientific payload. NASA has awarded ten contracts in the technology areas of Brayton, Stirling, Thermoelectric, and Thermophotovoltaic power conversion including five development contracts that deal with more mature technologies and five research contracts. The Advanced RPS Systems Assessment Team includes members from NASA GRC, JPL, DOE and Orbital Sciences whose function is to review the technologies being developed under the ten Radioisotope Power Conversion Technology contracts and assess their relevance to NASA's future missions. Presented is an overview of the ten radioisotope power conversion technology contracts and NASA's Advanced RPS Systems Assessment Team.

  12. Analysis of River sediments from the Tigre river (Venezuela) by radioisotope excited x-ray fluorescence

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Rosales, P.A.; Schorin, H.

    1985-01-01

    This paper describes qualitative elemental scans by both energy dispersive (radioisotope excited) and conventional wavelength dispersive x-ray fluorescence of different grain size fractions of river sediments. An internal standard thin-film technique was used. The precision of Rb, Sr, Y and Zr determination for SY-3 standard reference rock and one real sample for five independently prepared samples is demonstrated

  13. Research and development for the application of radioisotope technology in SINR

    International Nuclear Information System (INIS)

    Zhang Jiahua

    1987-01-01

    A brief systematic account on the research and development for the application of radioisotope technology in Shanghai Institute of Nuclear Research (SINR) is presented. It comprehensively covers the following categories: 1. Radioisotopes produced by cyclotron; 2. Radioisotope-labelled compounds; 3. Radioisotope as source of energy converter; 4. Induced-radioisotope generation as a means for elemental analysis--the activation analysis; 5. Radioisotope equipped with electronic instrument for various application; and 6. Special usage of some radioisotopes

  14. Radioisotope clocks in archaeology

    Energy Technology Data Exchange (ETDEWEB)

    Hedges, R E.M. [Oxford Univ. (UK). Research Lab. for Archaeology

    1979-09-06

    Methods of absolute dating which use the rate of disintegration of a radioactive nucleus as the clock, are reviewed. The use of the abundant radioisotopes (/sup 40/K, Th and U) and of the rare radioisotopes (/sup 14/C, /sup 10/Be, /sup 26/Al, /sup 32/Si, /sup 36/Cl, /sup 41/Ca, /sup 53/Mn) is discussed and radiation integration techniques (fission track dating, thermoluminescence and related techniques) are considered. Specific fields of use of the various methods and their accuracy are examined.

  15. Packaging and transport of radioisotopes

    International Nuclear Information System (INIS)

    Taylor, C.B.G.

    1976-01-01

    The importance of radioisotope traffic is emphasized. More than a million packages are being transported each year, mostly for medical uses. The involvement of public transport services and the incidental dose to the public (which is very small) are appreciably greater than for movements connected with the nuclear fuel cycle. Modern isotope packages are described, and an outline given of the problems of a large radioisotope manufacturer who has to package many different types of product. Difficulties caused by recent uncoordinated restrictions on the use of passenger aircraft are mentioned. Some specific problems relating to radioisotope packaging are discussed. These include the crush resistance of Type A packages, the closure of steel drums, the design of secure closures for large containers, the Type A packaging of liquids, leak tightness criteria of Type B packages, and the use of 'unit load' overpacks to consign a group of individually approved packages together as a single shipment. Reference is made to recent studies of the impact of radioisotope shipments on the environment. Cost/benefit analysis is important in this field - an important public debate is only just beginning. (author)

  16. Uses of radioisotopes in Sudan

    International Nuclear Information System (INIS)

    Elradi, E. A. M.

    2013-07-01

    In this research project, an inventory for the different radioisotopes that were imported by public and private sectors of Sudan in the period between ( 2007-2011) has been set up. These organizations import the appropriates for different but in general we classify them into these applications: Medical, Industrial, Agricultural and Research. However, each broad discipline is subdivided into subgroups. This inventory will help those who are willing to establish research reactors in Sudan on the type and power of the reactors to be purchases according to the actual needs of Sudan with forecasting of the near and for future needs. Also the expenditure that has been spent by these organizations have been estimated for most of the radioisotopes. It was observed that almost 50% of the expenditure went for the fright charges as these radioisotopes need special handling and care by installing a research reactor in Sudan, the cost of purchasing will be cut down several folds. Also it will help in availability of the radioisotopes with very short half lives (hours to days). This will be reflected in the cut down the cost of tests and provision of new tests.(Author)

  17. Two-color pump-probe laser spectroscopy instrument with picosecond time-resolved electronic delay and extended scan range

    Science.gov (United States)

    Yu, Anchi; Ye, Xiong; Ionascu, Dan; Cao, Wenxiang; Champion, Paul M.

    2005-11-01

    An electronically delayed two-color pump-probe instrument was developed using two synchronized laser systems. The instrument has picosecond time resolution and can perform scans over hundreds of nanoseconds without the beam divergence and walk-off effects that occur using standard spatial delay systems. A unique picosecond Ti :sapphire regenerative amplifier was also constructed without the need for pulse stretching and compressing optics. The picosecond regenerative amplifier has a broad wavelength tuning range, which suggests that it will make a significant contribution to two-color pump-probe experiments. To test this instrument we studied the rotational correlation relaxation of myoglobin (τr=8.2±0.5ns) in water as well as the geminate rebinding kinetics of oxygen to myoglobin (kg1=1.7×1011s-1, kg2=3.4×107s-1). The results are consistent with, and improve upon, previous studies.

  18. Novel Radioisotope Applications in Industry Promoted by the IAEA

    International Nuclear Information System (INIS)

    Thereska, J.

    2001-01-01

    Presently, there is a lively activity in further development and use of radioisotope technology. Novel radioisotope applications in industry are promoted by the IAEA. Radioisotope technology is contributing significantly to improving and optimising process performance bringing an annual economic benefit to world-wide industry of several billion US$. Probably, an average benefit to cost ratio of 40:1 is reasonably representative of radioisotope applications in industry. There are few short-term investments, which will give a return of this magnitude. The cost effectiveness of radioisotope applications should be widely promulgated to encourage industrialists to take full advantage of the technology. (author)

  19. Developments in radioisotope production and labelling of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1998-01-01

    Recent developments in both reactor and accelerator production of radioisotopes finding applications in nuclear medicine and in biomedical research are summarised. The priorities for the production of 48 different cyclotron radioisotopes; and for 42 reactor produced radioisotopes finding biomedical applications are identified. Each includes 5 generator systems. The rapid expansion of cyclotron based radioisotope production and automated synthesis of short-lived radiopharmaceuticals with the position-emitting radionuclides continues to gain momentum. Recent feasibility studies of the cyclotron production of 186 Re, 99m Tc and of 99 Mo are cited as examples of motivation to develop accelerator alternatives to use of nuclear reactors for medical radioisotope production. Examples of SPET and PET radiopharmaceuticals labelled with 131 I, 123 I, 124 I, 18 F, and with therapeutic radionuclides are highlighted. (author)

  20. Radioisotopes in soil science

    International Nuclear Information System (INIS)

    Kotur, S.C.

    2004-01-01

    Soils form a thin veneer of the Earth that sustain the entire flora and fauna of the terra firma. To that extent the soil as a natural resource is very precious and needs to be managed in a sustainable manner. The fate of degradation of pesticides in soil and build-up of heavy metals in the overall biosafety scenario is also studied gainfully using radioisotopes. Radioisotopes are a very potent tool in the hands of the Soil Scientists, perhaps, the most important among the peaceful applications in service of the mankind

  1. Radioisotopes and their applications in highway testings

    International Nuclear Information System (INIS)

    Saxena, S.C.

    1974-01-01

    Applications of radioisotopes in highway testing are described. Radioisotopic methods have been used to determine : (1) moisture and density of soil and base materials for compaction control, (2) magnesium oxide content of cement, (3) permeability of bituminous coverings and (4) field density of freshly laid hot bituminous concrete surface. Possible uses of nuclear explosives for production of aggregates and of radioisotopes for determination of deflection in the design of flexible pavements are indicated. (M.G.B.)

  2. Economical Radioisotope Power

    Data.gov (United States)

    National Aeronautics and Space Administration — Almost all robotic space exploration missions and all Apollo missions to the moon used Radioisotopic Thermoelectric Generators (RTGs) to provide electrical power to...

  3. Radioisotope thermoelectric generators for implanted pacemakers

    Energy Technology Data Exchange (ETDEWEB)

    Pustovalov, A.A.; Bovin, A.V.; Fedorets, V.I.; Shapovalov, V.P.

    1986-08-01

    This paper discusses the development and application of long-life lithium batteries and the problems associated with miniature radioisotope thermoelectric generators (RITEG) with service lives of 10 years or longer. On eof the main problems encountered when devising a radioisotope heat source (RHS) for an RITEG is to obtain biomedical /sup 238/PuO/sub 2/ with a specific neutron yield of 3.10/sup 3/-4.10/sup 3/ (g /SUP ./ sec)/sup -1/, equivalent to metallic Pu 238, and with a content of gamma impurities sufficient to ensure a permissible exposure a permissible exposure does rate (EDR) of a mixture of neutron and gamma radiation. After carrying out the isotope exchange and purifying the initial sample of its gamma impurity elements, the authors obtain biomedical Pu 238 satisfying the indicated requirements king suitable for use in the power packs of medical devices. Taking the indicated specifications into account, the Ritm-1o and gamma radioisotope heat sources were designed, built, tested in models and under natural conditions, and then into production as radioisotope thermoelectric generators designed to power the electronic circuits of implanted pacemakers. The Ritm-MT and Gemma radioisotope thermoelectric generators described are basic units, which can be used as self-contained power supplies for electronic equipment with power requirements in the micromilliwatt range.

  4. Radioisotope production linac

    International Nuclear Information System (INIS)

    Stovall, J.E.; Hansborough, L.D.; O'Brien, H.A.

    1981-01-01

    A 70-MeV proton beam would open a new family of medical radioisotopes (including the important 123 I) to wide application. A 70-MeV, 500-μA linac is described, based on recent innovations in accelerator technology. It would be 27.3 m long, cost approx. $6 million, and the cost of power deposited in the radioisotope-production target is comparable to existing cyclotrons. By operating the rf-power system to its full capability, the same accelerator is capable of producing a 1140-μA beam, and the cost per beam watt on the target is less than half that of comparable cyclotrons. The technology to build such a linac is in a mature stage of developmnt, ready for use by industry

  5. Industrial applications of radioisotope tracers

    International Nuclear Information System (INIS)

    Easey, J.F.

    1985-01-01

    Radioisotope tracing techniques are powerful tools for analysing the behaviour of large systems and investigating industrially or economically important processes. The results of radioisotope experiments can yield important information, for example, on parameters such as flow rates, mixing phenomena, flow abnormalities and leaks. Some examples of current AAEC research are described, covering studies on hearth drainage in blast furnaces, flow behaviour in waste-water treatment ponds, and sediment transport in marine environments

  6. Assessment of radioisotope heaters for remote terrestrial applications

    International Nuclear Information System (INIS)

    Uherka, K.L.

    1987-05-01

    This paper examines the feasibility of using radioisotope byproducts for special heating applications at remote sites in Alaska and other cold regions. The investigation included assessment of candidate radioisotope materials for heater applications, identification of the most promising cold region applications, evaluation of key technical issues and implementation constraints, and development of conceptual heater designs for candidate applications. Strontium-90 (Sr-90) was selected as the most viable fuel for radioisotopic heaters used in terrestrial applications. Opportunities for the application of radioisotopic heaters were determined through site visits to representative Alaska installations. Candidate heater applications included water storage tanks, sludge digesters, sewage lagoons, water piping systems, well-head pumping stations, emergency shelters, and fuel storage tank deicers. Radioisotopic heaters for water storage tank freeze-up protection and for enhancement of biological waste treatment processes at remote sites were selected as the most promising applications

  7. A set of portable radioisotopic control and measuring instruments

    International Nuclear Information System (INIS)

    Pospeev, V.V.; Sidorov, V.N.; Tesnavs, Eh.R.; Uleksin, V.I.

    1979-01-01

    The problems and perspectives are examined of the portable radioisotope instruments application in agriculture, building industry, engeeniring and geological survay and in melioration. Principles are given of creation a series of radioisotopic instruments based on the principle of ganging. The series described consists of radioisotopic densimeters and moisture gages of the portable type, based on the ganging principle. The instruments differ in the measuring converters and have unified information processing and power supply devices. Criteria are stated for the ganging principle estimation, in particular, estimation of the technical means' compatibility. Four different types of compatibility are distinguished: an information compatibility; a metrological compatibility; structural and operational compatibility. Description is given of the unified information processing device - the unified pulse counter of the SIP-1M type and description of a row of radioisotopic measuring converters, which provides a possibility for completing the portable radioisotope densimeter of the RPP-2 type, intended for measuring densities of concrets and soils in the surface layer up to 30 cm and the density range from 1000 to 2500 kg/m 3 ; portable radioisotope densimeter of the RPP-1 type having measuring range from 600 to 1500 kg/m 3 ; surface-depth radioisotopic densimeter of the PPGR-1 type and surface-depth radioisotopic moisture gage of the VPGR-1 type [ru

  8. Radioisotopic indicators in microbiology

    International Nuclear Information System (INIS)

    Isamov, N.N.

    1976-01-01

    The book comprises data obtained by the laboratory of radiobiology (Uzbek Research Veterinary Institute) for 15 years and sums up data of domestic and foreign scientists; it discusses problems of the utilization of radioactive isotopes of sulphur, cadmium, phosphorus and other chemical elements by microorganisms; indicates the specificity of the utilization of radioisotopes in microbiology. The influence is considered of external factors on the inclusion of radioisotopes into microorganisms, methods are discussed of obtaining labelled microorganisms and their antigens, radioactivity of bacteria is considered as affected by the consistency and composition of the nutritive medium and other problems

  9. Abstracts of the third conference on radioisotopes and their applications

    International Nuclear Information System (INIS)

    2002-10-01

    The Third Uzbekistan Conference on radioisotopes and their applications was held on 8-10 October, 2002 in Tashkent, Uzbekistan. The specialists discussed various aspects of modern problems of radiochemistry, radioisotope production, technology of radioisotopes and compounds, activations analysis applications, radionuclides, radioimmunoassays, application of radioisotopes in industry, medicine, biology and agriculture. More than 80 talks were presented in the meeting

  10. Computerized control system for administration of the radioisotope use

    International Nuclear Information System (INIS)

    Sago, Tsutomu; Ito, Shin; Isozumi, Yasuhito; Kurihara, Norio

    1986-01-01

    An on-line computer system for administration of the radioisotope use has been developed. This system consists of a multi-job type host computer and two sets of personal computers with identification card-readers. The personal computers are employed as terminal devices for radioisotope users. By the use of an identification card, entrance and leaving times are recorded automatically. Furthermore, an easy operation of the personal computer permits users to access to the information of their resistered radioisotopes, such as nuclides, chemical forms, updated activities, storage locations, and history of usage. A recording sheet on which those data are printed is provided from the personal computer. After the use of radioisotopes, users can record their data on the recording sheets. These records are used as the input data to this system to update the data of the used radioisotopes. Owing to the concise format of the recording sheet and various sorting programs developed in present work, this system enables us to grasp the exact flow of the radioisotopes from purchase to disposal. Out-put data from high-speed kanji printer can provide many important books which are legally requested to be kept for administration of the radioisotope use. (author)

  11. The production and application of radioisotopes

    International Nuclear Information System (INIS)

    O'Neill, W.P.; Evans, D.J.R.

    1987-01-01

    This paper outlines the historical evolution of radioisotopes from first concepts and discoveries to significant milestones in their production and the development of applications throughout the world. Regarding production, it addresses the methods that have been used at various stages during this evolution outlining the important findings that have led to further developments. With respect to radioisotope applications, the paper addresses the development of markets in industry, medicine, and agriculture and comments on the size of these markets and their rate of growth. Throughout, the paper highlights the Canadian experience and it also presents a Canadian view of emerging prospects and a forecast of how the future for radioisotopes might develop. (author)

  12. Twenty years of Korea radioisotope association history

    International Nuclear Information System (INIS)

    2005-09-01

    This contents has two parts. The first part describes the present and post of Korea radioisotope association which are about the foundation of the association, organization, main projects and vision of the association. The second part is about the use and the prospect of radiation and radioisotope in Korea, which shows the plan of expansion of use of radiation and radioisotope, the prospect and present condition in fields such as medical, industry and farming, product and distribution, research and development of human resources, system and management of safety of radiation.

  13. Colored cool colorants based on rare earth metal ions

    Energy Technology Data Exchange (ETDEWEB)

    Sreeram, Kalarical Janardhanan; Aby, Cheruvathoor Poulose; Nair, Balachandran Unni; Ramasami, Thirumalachari [Chemical Laboratory, Central Leather Research Institute, Council of Scientific and Industrial Research, Adyar, Chennai 600 020 (India)

    2008-11-15

    Colored pigments with high near infrared reflectance and not based on toxic metal ions like cadmium, lead and cobalt are being sought as cool colorants. Through appropriate doping two pigments Ce-Pr-Mo and Ce-Pr-Fe have been developed to offer a reddish brown and reddish orange color, respectively. These pigments have been characterized and found to be highly crystalline with an average size of 300 nm. A shift in band gap energy from 2.21 to 2.18 eV has been observed when Li{sub 2}CO{sub 3} was used as a mineralizer. Scanning electron microscope-energy dispersive X-ray analysis (SEM-EDAX) measurement indicate a uniform grind shape and distribution of metal ion, with over 65% reflectance in the NIR region, these pigments can well serve as cool colorants. (author)

  14. Abstracts of the second conference on radioisotopes and their applications

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-10-01

    The Second Uzbekistan Conference on radioisotopes and their applications was held on 3-5 October, 2000 in Tashkent, Uzbekistan. The specialists discussed various aspects of modern problems of radiochemistry, radioisotope production, technology of radioisotopes and compounds, activations analysis applications, radionuclides, radioimmunoassays, application of radioisotopes in industry, medicine, biology and agriculture. More than 80 talks were presented in the meeting. (A.A.D.)

  15. Radioisotope methodology course radioprotection aspects

    International Nuclear Information System (INIS)

    Bergoc, R.M.; Caro, R.A.; Menossi, C.A.

    1996-01-01

    The advancement knowledge in molecular and cell biology, biochemistry, medicine and pharmacology, which has taken place during the last 50 years, after World War II finalization, is really outstanding. It can be safely said that this fact is principally due to the application of radioisotope techniques. The research on metabolisms, biodistribution of pharmaceuticals, pharmacodynamics, etc., is mostly carried out by means of techniques employing radioactive materials. Radioisotopes and radiation are frequently used in medicine both as diagnostic and therapeutic tools. The radioimmunoanalysis is today a routine method in endocrinology and in general clinical medicine. The receptor determination and characterization is a steadily growing methodology used in clinical biochemistry, pharmacology and medicine. The use of radiopharmaceuticals and radiation of different origins, for therapeutic purposes, should not be overlooked. For these reasons, the importance to teach radioisotope methodology is steadily growing. This is principally the case for specialization at the post-graduate level but at the pre graduate curriculum it is worthwhile to give some elementary theoretical and practical notions on this subject. These observations are justified by a more than 30 years teaching experience at both levels at the School of Pharmacy and Biochemistry of the University of Buenos Aires, Argentina. In 1960 we began to teach Physics III, an obligatory pregraduate course for biochemistry students, in which some elementary notions of radioactivity and measurement techniques were given. Successive modifications of the biochemistry pregraduate curriculum incorporated radiochemistry as an elective subject and since 1978, radioisotope methodology, as obligatory subject for biochemistry students. This subject is given at the radioisotope laboratory during the first semester of each year and its objective is to provide theoretical and practical knowledge to the biochemistry students, even

  16. Radioisotope production by reactors and cyclotrons in Japan

    International Nuclear Information System (INIS)

    Murakami, Yukio

    1978-01-01

    Present status of radioisotope production in Japan and the increasing demand from various fields are generally reviewed. Future problems associated with the shortage of economical supply are also discussed. The first half of this report is devoted to general review of the increasing demand for various radioisotopes from increasing number of users. The present status and future trends of the distribution of users of specific radioisotopes and their demands are shown. The remaining half of this report reviews the production with reactors and cyclotrons. The Japanese reactors producing radioisotopes are limited to low flux (10 13 ) research reactors at JAERI. Some problems associated with the improvement of availability and with the organizational structure are discussed. As for the production with cyclotrons, available facilities and the method of production are explained in detail. For clinical use, especially for the production of short lived radioisotopes, the advantage of a small special purpose cyclotron at each medical organization is emphasized. (Aoki, K.)

  17. Technical and economical availability of radioisotopes production in Brazil

    International Nuclear Information System (INIS)

    Lima, J.O.V.

    1981-10-01

    The technical and economical availability of radioisotopes production in Brazil by a low power research reactor, are done. The importance of radioisotope utilization and controled radiations, in areas such as medicine, industry and cost evaluation for the production in nuclear reactors. In the cost evaluation of a radioisotope production reactor, the studies developed by the Department of Nuclear Engineering of Universidade Federal de Minas Gerais - DEN/UFMG were used. The information analysis justify the technical and economical availability and the necessity of the radioisotopes production in Brazil. (E.G.) [pt

  18. Elementary concepts of the radioisotopes uses

    International Nuclear Information System (INIS)

    Pisarev, Mario A.

    2004-01-01

    Endocrinology has been one of the specialties earlier benefited for the radioisotopes uses in the diagnosis and treatment of different affections. These applications are based on the radioisotopes property of biochemical behaving as non- radioactive molecules, and at the same time, radiations emitting that can be detected by suitable means (diagnostic utility) or that have effects on biological systems (therapeutic action). (author) [es

  19. Development and application of industrial radioisotope instruments in China

    International Nuclear Information System (INIS)

    Lu Yanxiao

    1994-09-01

    Industrial radioisotope instruments are emerging as advanced monitoring, controlling and automation tools for industries in China. Especially the on-line analysis systems based on radioisotope instruments, referred to as nucleonic control systems (NCS), have more and more important role in the modernization and optimization of industrial processes. Over nearly four decades significant progress has been made in the development and application of radioisotope instruments in China. After a brief review of the history of radioisotope instruments, the state of the art of this kind of instruments and recent examples of their applications are given. Technical and economic benefits have resulted from the industrial applications of radioisotope instruments and the sales of products of their own in marketing. It is expected that along with the high speed growth of national economy, there will be greater demand for radioisotope instruments and nucleonic control systems in Chinese industry to promote the technological transformation and progress of traditional industries and to establish high-tech industries with technology-intensive products. Sustained efforts for the research and development of radioisotope instrument should be made to up-grade domestic instruments and to satisfy the needs of the smaller scale industries more common in China for low cost systems. (1 fig., 2 tabs.)

  20. Radioisotope-powered photovoltaic generator

    International Nuclear Information System (INIS)

    McKlveen, J.W.; Uselman, J.

    1979-01-01

    Disposing of radioactive wastes from nuclear power plants has become one of the most important issues facing the nuclear industry. In a new concept, called a radioisotope photovoltaic generator, a portion of this waste would be used in conjunction with a scintillation material to produce light, with subsequent conversion into electricity via photovoltaic cells. Three types of scintillators and two types of silicon cells were tested in six combinations using 32 P as the radioisotope. The highest system efficiency, determined to be 0.5% when the light intensity was normalized to 100 mW/cm 2 , was obtained using a CsI crystal scintillator and a Helios photovoltaic cell

  1. RADIOISOTOPE INVENTORY FOR TSPA-SR

    International Nuclear Information System (INIS)

    Leigh, C.; Rechard, R.

    2001-01-01

    The total system performance assessment for site recommendation (TSPA-SR), on Yucca Mountain, as a site (if suitable) for disposal of radioactive waste, consists of several models. The Waste Form Degradation Model (i.e, source term) of the TSPA-SR, in turn, consists of several components. The Inventory Component, discussed here, defines the inventory of 26 radioisotopes for three representative waste categories: (1) commercial spent nuclear fuel (CSNF), (2) US Department of Energy (DOE) spent nuclear fuel (DSNF), and (3) high-level waste (HLW). These three categories are contained and disposed of in two types of waste packages (WPs)--CSNF WPs and co-disposal WPs, with the latter containing both DSNF and HLW. Three topics are summarized in this paper: first, the transport of radioisotopes evaluated in the past; second, the development of the inventory for the two WP types; and third, the selection of the most important radioisotopes to track in TSPA-SR

  2. Aspects of radioisotopes utilization in clinical medicine

    International Nuclear Information System (INIS)

    Rocha, A.F.G.; Lima e Forti, C.A. de; Cunha, M. da C.; Souza Maciel, O. de

    1973-01-01

    A revision concerning radioisotope use in Medicine have been dow. Harmless and effeciency of radioisotopes are shown. Techniques and advantages of tracers used for brain scintiscanning, lung scintiscanning, liver scintinscanning, spleen scintiscanning, bone scintiscanning and thyroid scintiscanning are described and images of them are presented [pt

  3. Structure and manual of radioisotope-production data base, ISOP

    International Nuclear Information System (INIS)

    Hata, Kentaro; Terunuma, Kusuo

    1994-02-01

    We planned on collecting the information of radioisotope production which was obtained from research works and tasks at the Department of Radioisotopes in JAERI, and constructed a proto-type data base ISOP after discussion of the kinds and properties of the information available for radioisotope production. In this report the structure and the manual of ISOP are described. (author)

  4. Radioisotopes in non-destructive testing

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1976-12-01

    After defining nondestructive testing (NDT) and comparing this concept with destructive testing, a short description is given of NDT methods other than radiologic. The basic concepts of radiologic methods are discussed and the principles of radiography are explained. Radiation sources and gamma radiography machines are next reviewed and radiographic inspection of weldings and castings is described. A brief description is given of the radiographic darkroom and accessories. Other radioisotope methods, such as neutron radiography, are shortly reviewed. Cost estimations for radioisotopic equipment conclude the report. (author)

  5. Radioisotope production at PUSPATI - five year programme

    International Nuclear Information System (INIS)

    Yusof Azuddin Ali; Abdul Rahman Mohamad Ali.

    1983-01-01

    Most of the basic laboratory facilities for radioisotopes production at PUSPATI will be commissioned by September 1983. Work on setting up of production and dispensing facilities is in progress as the nuclides being worked on are those that are commonly used in medical applications, such as Tc-99m, I-131, P-32 and other nuclides such as Na-24 and K-42. Kits for compounds labelled with Tc-99m such as Stannous Pyrophosphate, Sulfur Colloid and Stannous Glucoheptonate are being prepared. The irradiation facilities available now for radioisotope production at the PUSPATI TRIGA Reactor include a central thimble (flux density 1 x 10 13 n.cm -2 S -1 ) and a rotary specimen rack (flux density 0.2 x 10 13 n.cm -1 S -1 ). Irradiation schedules and target handling techniqes are discussed. Plans for radioisotope production at PUSPATI over the period of 1983-1987, based on present demand for radioisotope, are also explained. (author)

  6. Radioisotopes: problems of responsibility arising from medicine

    International Nuclear Information System (INIS)

    Dupon, Michel.

    1978-09-01

    Radioisotopes have brought about great progress in the battle against illnesses of mainly tumoral origin, whether in diagnosis (nuclear medicine) or in treatment (medical radiotherapy). They are important enough therefore to warrant investigation. Such a study is attempted here, with special emphasis, at a time when medical responsibility proceedings are being taken more and more often on the medicolegal problems arising from their medical use. It is hoped that this study on medical responsibility in the use of radioisotopes will have shown: that the use of radioisotopes for either diagnosis or therapy constitutes a major banch of medicine; that this importance implies an awareness by the practitioner of a vast responsibility, especially in law where legislation to ensure protection as strict as in the field of ionizing radiations is lacking. The civil responsibility of doctors who use radioisotopes remains to be defined, since for want of adequate jurisprudence we are reduced to hypotheses based on general principles [fr

  7. Radioisotope Production for Medical and Physics Applications

    Science.gov (United States)

    Mausner, Leonard

    2012-10-01

    Radioisotopes are critical to the science and technology base of the US. Discoveries and applications made as a result of the availability of radioisotopes span widely from medicine, biology, physics, chemistry and homeland security. The clinical use of radioisotopes for medical diagnosis is the largest sector of use, with about 16 million procedures a year in the US. The use of ^99Mo/^99mTc generator and ^18F make up the majority, but ^201Tl, ^123I, ^111In, and ^67Ga are also used routinely to perform imaging of organ function. Application of radioisotopes for therapy is dominated by use of ^131I for thyroid malignancies, ^90Y for some solid tumors, and ^89Sr for bone cancer, but production of several more exotic species such as ^225Ac and ^211At are of significant current research interest. In physics ^225Ra is of interest for CP violation studies, and the actinides ^242Am, ^249Bk, and ^254Es are needed as targets for experiments to create superheavy elements. Large amounts of ^252Cf are needed as a fission source for the CARIBU experiment at ANL. The process of radioisotope production is multidisciplinary. Nuclear physics input based on nuclear reaction excitation function data is needed to choose an optimum target/projectile in order to maximize desired isotope production and minimize unwanted byproducts. Mechanical engineering is needed to address issues of target heating, induced mechanical stress and material compatibility of target and claddings. Radiochemists are involved as well since chemical separation to purify the desired final radioisotope product from the bulk target and impurities is also usually necessary. Most neutron rich species are produced at a few government and university reactors. Other radioisotopes are produced in cyclotrons in the commercial sector, university/hospital based facilities, and larger devices at the DOE labs. The landscape of US facilities, the techniques involved, and current supply challenges will be reviewed.

  8. Comparison of the production of medical radioisotopes on reactor and cyclotron

    International Nuclear Information System (INIS)

    Vucina, J.; Vuksanovic, Lj.; Dobrijevic, R.; Karanfilov, E.

    1997-01-01

    The production of radioisotopes for nuclear-medical applications can be performed either on nuclear reactor or on cyclotron. According to the nuclear reactions applied the radioisotopes of different physical characteristics can be produced. In the paper a comparison of the radioisotopes production given. Compared are the main steps in the production: choice of the nuclear reaction, targetry, irradiation and radiochemical separations performed on the irradiated target to isolate the desired radioisotope. The main characteristics of the produced radioisotopes are given and discussed. (author)

  9. Predictive efficacy of radioisotope voiding cystography for renal outcome

    International Nuclear Information System (INIS)

    Kim, Seok Ki; Lee, Dong Soo; Kim, Kwang Myeung; Choi, Whang; Chung, June Key; Lee, Myung Chul

    2000-01-01

    As vesicoureteral reflux (VUR) could lead to renal functional deterioration when combined with urinary tract infection, we need to decide whether operative anti-reflux treatment should be performed at the time of diagnosis of VUR. Predictive value of radioisotope voiding cystography (RIVCG) for renal outcome was tested. In 35 children (18 males, 17 females), radiologic voiding cystoure-thrography (VCU), RIVCG and DMSA scan were performed. Change in renal function was evaluated using the follow-up DMSA scan, ultrasonography, and clinical information. Discriminant analysis was performed using individual or integrated variables such as reflux amount and extent at each phase of voiding on RIVCG, in addition to age, gender and cortical defect on DMSA scan at the time of diagnosis. Discriminant function was composed and its performance was examined. Reflux extent at the filling phase and reflux amount and extent at postvoiding phase had a significant prognostic value. Total reflux amount was a composite variable to predict prognosis. Discriminant function composed of reflux extent at the filling phase and reflux amount and extent at postvoiding phase showed better positive predictive value and specificity than conventional reflux grading. RIVCG could predict renal outcome by disclosing characteristic reflux pattern during various voiding phases.=20

  10. Use of radioisotopes and nuclear methods in metallurgy

    International Nuclear Information System (INIS)

    Trehber, K.

    1976-01-01

    Some kinds of using radioisotope methods and instruments for regulation and control of metallurgical processes are reviewed. Computized data processing is described as well. The efficiency of industrial application of radioisotopes is remarked

  11. Radio-isotope generator

    International Nuclear Information System (INIS)

    Benjamins, H.M.

    1983-01-01

    A device is claimed for interrupting an elution process in a radioisotope generator before an elution vial is entirely filled. The generator is simultaneously exposed to sterile air both in the direction of the generator column and of the elution vial

  12. HAC and production of radioisotopes and labelled compounds

    International Nuclear Information System (INIS)

    Nozaki, T.

    1984-01-01

    In this paper, the author reviews different methods for the production of radioisotopes and labelled compounds that make use of hot atom reactions. Subsequently he discusses the production of radioisotopes for radiopharmaceuticals; enrichment of (n,γ) products, recoil labelling and related methods (neutron reaction products, cyclotron production, excitation labelling, radiation and discharge induced labelling). The final section offers a survey of radioisotope production using accelerators. Only a selection of the various conditions used in practical RI production is considered. (Auth.)

  13. Radioisotope laboratory in Turkey

    International Nuclear Information System (INIS)

    1961-01-01

    The Turkish Government formally requested that the Agency provide for one year the services of an expert in the agricultural applications of radioisotopes. Specifically, they wanted this expert first of all to assist in setting up and equipping a pioneer laboratory for the utilization of radioisotopes in agricultural research. Once the laboratory was in operation, the expert was to initiate various research projects using isotope techniques, and to train personnel to carry on this work. The Agency was also asked to supply various specialized equipment for the laboratory, including some radioisotopes. On 10 December 1960 the first phase was complete - the new laboratory was formally opened. It is foreseen that the research projects which will be initiated at the laboratory will include the following: determination of the effect of fertilizers upon yield and quality of field crops and fruit trees, soil fertility studies, studies of mineral element uptake and localization of nutrients in plant body, studies of the folar application of mineral nutrients, especially in fruit trees, investigation of microelements in field crops and fruit trees, investigation of pollination problems, study of the distribution of mineral elements in different fruit seedlings, study of the uptake of nutrients by fruit trees during the rest period, dispersal studies on insects, insecticide studies

  14. Radioisotope laboratory in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-04-15

    The Turkish Government formally requested that the Agency provide for one year the services of an expert in the agricultural applications of radioisotopes. Specifically, they wanted this expert first of all to assist in setting up and equipping a pioneer laboratory for the utilization of radioisotopes in agricultural research. Once the laboratory was in operation, the expert was to initiate various research projects using isotope techniques, and to train personnel to carry on this work. The Agency was also asked to supply various specialized equipment for the laboratory, including some radioisotopes. On 10 December 1960 the first phase was complete - the new laboratory was formally opened. It is foreseen that the research projects which will be initiated at the laboratory will include the following: determination of the effect of fertilizers upon yield and quality of field crops and fruit trees, soil fertility studies, studies of mineral element uptake and localization of nutrients in plant body, studies of the folar application of mineral nutrients, especially in fruit trees, investigation of microelements in field crops and fruit trees, investigation of pollination problems, study of the distribution of mineral elements in different fruit seedlings, study of the uptake of nutrients by fruit trees during the rest period, dispersal studies on insects, insecticide studies.

  15. Radioisotopes for medical applications

    International Nuclear Information System (INIS)

    Carr, S.

    1998-01-01

    For more than 3 decades, the Australian Nuclear Science and Technology Organisation has been the country's main supplier of radioisotopes for medical applications. The use of radioisotopes in medicine has revolutionised the diagnosis, management and treatment of many serious diseases such as cancer, heart disease and stroke. It is also beginning to play a key role in neurological disorders such as Parkinson and Alzheimers disease and epilepsy. More recently there has been considerable growth in the application of nuclear medicine to treat sport-related injuries - especially wrist, ankle and knees where more common techniques do not always enable accurate diagnosis. Australia is a recognised leader in nuclear medicine. This can be partially attributed to the close relationship between ANSTO and the medical community in providing opportunities to develop and evaluate new agents to support more effective patient care. A list of commercial isotopes produced in the reactor or the cyclotron and used in medical applications is given. Nuclear medicine plays an important role in the clinical environment and the timely supply of radioisotopes is a key element. ANSTO will continue to be the premier supplier of currently available and developing isotopes to support the health and well being of the Australian community

  16. Radioisotopes for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Carr, S. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia). Radiopharmaceuticals Division

    1998-03-01

    For more than 3 decades, the Australian Nuclear Science and Technology Organisation has been the country`s main supplier of radioisotopes for medical applications. The use of radioisotopes in medicine has revolutionised the diagnosis, management and treatment of many serious diseases such as cancer, heart disease and stroke. It is also beginning to play a key role in neurological disorders such as Parkinson and Alzheimers disease and epilepsy. More recently there has been considerable growth in the application of nuclear medicine to treat sport-related injuries - especially wrist, ankle and knees where more common techniques do not always enable accurate diagnosis. Australia is a recognised leader in nuclear medicine. This can be partially attributed to the close relationship between ANSTO and the medical community in providing opportunities to develop and evaluate new agents to support more effective patient care. A list of commercial isotopes produced in the reactor or the cyclotron and used in medical applications is given. Nuclear medicine plays an important role in the clinical environment and the timely supply of radioisotopes is a key element. ANSTO will continue to be the premier supplier of currently available and developing isotopes to support the health and well being of the Australian community 2 tabs., 1 fig.

  17. Vitrified chemically bonded phosphate ceramics for immobilization of radioisotopes

    Science.gov (United States)

    Wagh, Arun S.

    2016-04-05

    A method of immobilizing a radioisotope and vitrified chemically bonded phosphate ceramic (CBPC) articles formed by the method are described. The method comprises combining a radioisotope-containing material, MgO, a source of phosphate, and optionally, a reducing agent, in water at a temperature of less than 100.degree. C. to form a slurry; curing the slurry to form a solid intermediate CBPC article comprising the radioisotope therefrom; comminuting the intermediate CBPC article, mixing the comminuted material with glass frits, and heating the mixture at a temperature in the range of about 900 to about 1500.degree. C. to form a vitrified CBPC article comprising the radioisotope immobilized therein.

  18. Radioisotopes as Political Instruments, 1946-1953.

    Science.gov (United States)

    Creager, Angela N H

    2009-01-01

    The development of nuclear "piles," soon called reactors, in the Manhattan Project provided a new technology for manufacturing radioactive isotopes. Radioisotopes, unstable variants of chemical elements that give off detectable radiation upon decay, were available in small amounts for use in research and therapy before World War II. In 1946, the U.S. government began utilizing one of its first reactors, dubbed X-10 at Oak Ridge, as a production facility for radioisotopes available for purchase to civilian institutions. This program of the U.S. Atomic Energy Commission was meant to exemplify the peacetime dividends of atomic energy. The numerous requests from scientists outside the United States, however, sparked a political debate about whether the Commission should or even could export radioisotopes. This controversy manifested the tension in U.S. politics between scientific internationalism as a tool of diplomacy, associated with the aims of the Marshall Plan, and the desire to safeguard the country's atomic monopoly at all costs, linked to American anti-Communism. This essay examines the various ways in which radioisotopes were used as political instruments-both by the U.S. federal government in world affairs, and by critics of the civilian control of atomic energy-in the early Cold War.

  19. Notification determining details of technical standards concerning transport of radioisotopes or goods contaminated by radioisotopes in works or enterprises

    International Nuclear Information System (INIS)

    1981-01-01

    This rule is established under the provisions of the regulation for the execution of the law on the prevention of radiation injuries by radioisotopes. Terms are used in this rule for the same meanings as in the regulation. The limit of the concentration of radioisotopes in the goods contaminated by these isotopes which are not required to be sealed in containers defined by the Director General of the Science and Technology Agency is 1/10,000 of the value A 2 under the notification determining the details of technical standards concerning the transport of radioisotopes or the goods contaminated by radioisotopes outside works or enterprises. The application for the permission of transporting the goods which are highly difficult to be sealed in containers shall list names and addresses, the kinds, quantities, shapes and properties of the transported goods contaminated by radioisotopes, etc. The radiation dose rate of transported goods and vehicles under the regulation is 200 milli-rem an hour on the surfaces of these goods, vehicles and containers, and 10 milli-rem an hour at the distance of 1 meter from their surfaces. The permissible exposure dose of the persons engaging in transport is 1.5 rem a year. Dangerous goods, signs, and the application for the approval of special measures are specified, respectively. (Okada, K.)

  20. Seven Things to Know about Radioisotopes

    International Nuclear Information System (INIS)

    Henriques, Sasha

    2014-01-01

    Each atomic element knows exactly how many protons and neutrons it needs at its centre (nucleus) in order to be stable (stay in its elemental form). Radioisotopes are atomic elements that do not have the correct proton to neutron ratio to remain stable. With an unbalanced number of protons and neutrons, energy is given off by the atom in an attempt to become stable. For example, a stable carbon atom has six protons and six neutrons. Whereas its unstable (and therefore radioactive) isotope carbon-14, has six protons and eight neutrons. Carbon-14 and all other unstable elements are called radioisotopes. This movement towards stability, which involves emitting energy from the atom in the form of radiation, is known as radioactive decay. This radiation can be tracked and measured, making radioisotopes very useful in industry, agriculture and medicine

  1. Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1987-04-01

    A color laser microscope utilizing a new color laser imaging system has been developed for the visual inspection of semiconductors. The light source, produced by three lasers (Red; He-Ne, Green; Ar, Blue; He-Cd), is deflected horizontally by an AOD (Acoustic Optical Deflector) and vertically by a vibration mirror. The laser beam is focused in a small spot which is scanned over the sample at high speed. The light reflected back from the sample is reformed to contain linear information by returning to the original vibration mirror. The linear light is guided to the CCD image sensor where it is converted into a video signal. Individual CCD image sensors are used for each of the three R, G, or B color image signals. The confocal optical system with its laser light source yields a color TV monitor image with no flaring and a much sharper resolution than that of the conventional optical microscope. The AOD makes possible a high speed laser scan and a NTSC or PAL TV video signal is produced in real time without any video memory. Since the light source is composed of R, G, and B laser beams, color separation superior to that of white light illumination is achieved. Because of the photometric linearity of the image detector, the R, G, and B outputs of the system are most suitably used for hue analysis. The CCD linear image sensors in the optical system produce no geometrical distortion, and good color registration is available principally. The output signal can be used for high accuracy line width measuring. The many features of the color laser microscope make it ideally suited for the visual inspection of semiconductor processing. A number of these systems have already been installed in such a capacity. The Color Laser Microscope can also be a very useful tool for the fields of material engineering and biotechnology.

  2. Radioisotopes for therapy: an overview

    International Nuclear Information System (INIS)

    Venkatesh, Meera

    2006-01-01

    Radionuclides made great impact in the history of nuclear sciences both at the end of 19th century with the discoveries of Becquerel and madame Curie and later in 1934, when Frederic Joliet and Irene Curie demonstrated the production of the first artificial radioisotopes, 30 P, by bombardment of 27 Al by alpha particles. The subsequent invention of cyclotron and setting up of nuclear reactor opened the floodgate for production of artificial radionuclides. Currently, majority of radionuclides are made artificially by transforming a stable nuclide into an unstable state and thus far over 2500 radionuclides have been produced artificially. Use of radionuclides in various fields immediately followed their production and last century has witnessed tremendous growth in the applications of radiation and radioisotopes, in diverse fields such as medicine, industry, agriculture, food preservation, water resource management, environmental studies, etc. While radiation and radioisotopes are used both for diagnosis as well as for therapy in the field of medicine, therapeutic applications are among the earliest, which began as an empirical science in the beginning and developed into a well structured modality with time. (author)

  3. Radioisotopes in Industry

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Philip S. [Oak Ridge National Laboratory; Fuccillo, Jr., Domenic A. [Oak Ridge National Laboratory; Gerrard, Martha W. [Oak Ridge National Laboratory; Lafferty, Jr., Robert H. [Oak Ridge National Laboratory

    1967-05-01

    Radioisotopes, man-made radioactive elements, are used in industry primarily for measuring, testing and processing. How and why they are useful is the subject of this booklet. The booklet discusses their origin, their properties, their uses, and how they may be used in the future.

  4. Radiation protection programme for a radioisotope production facility

    International Nuclear Information System (INIS)

    Makgato, Thutu Nelson

    2015-02-01

    The present project reviews reactor based radioisotope production facilities. An overview of techniques and methodologies used as well as laboratory facilities necessary for the production process are discussed. Specific details of reactor based production and processing of more commonly used industrial and pharmaceutical radioisotopes are provided. Ultimately, based on facilities and techniques utilized as well as the associated hazard assessment, a proposed radiation protection programme is discussed. Elements of the radiation protection programme will also consider lessons from recent incidents and accidents encountered in radioisotope production facilities. (au)

  5. Radioisotope research and development at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Peterson, E.J.

    1993-01-01

    Throughout its fifty year history, Los Alamos National Laboratory has conducted research and development in the production, isolation, purification, and application of radioactive isotopes. Initially this work supported the weapons development mission of the Laboratory. Over the years the work has evolved to support basic and applied research in many diverse fields, including nuclear medicine, biomedical studies, materials science, environmental research and the physical sciences. In the early 1970s people in the Medical Radioisotope Research Program began irradiating targets at the Los Alamos Meson Physics Facility (LAMPF) to investigate the production and recovery of medically important radioisotopes. Since then spallation production using the high intensity beam at LAMPF has become a significant source of many important radioisotopes. Los Alamos posesses other facilities with isotope production capabilities. Examples are the Omega West Reactor (OWR) and the Van de Graaf Ion Beam Facility (IBF). Historically these facilities have had limited availability for radioisotope production, but recent developments portend a significant radioisotope production mission in the future

  6. Shielded radioisotope generator and method for using same

    International Nuclear Information System (INIS)

    Fries, B.A.

    1976-01-01

    A nuclide generator for on-site radioisotope generation is disclosed in which the formation of a short-lived daughter radioisotope from its longer-lived parent features batch flow of eluting reagent interior of the generator in a completely shielded environment

  7. Radioisotopes and radiopharmaceuticals catalogue

    International Nuclear Information System (INIS)

    2002-01-01

    The Chilean Nuclear Energy Commission (CCHEN) presents its radioisotopes and radiopharmaceuticals 2002 catalogue. In it we found physical characteristics of 9 different reactor produced radioisotopes ( Tc-99m, I-131, Sm-153, Ir-192, P-32, Na-24, K-42, Cu-64, Rb-86 ), 7 radiopharmaceuticals ( MDP, DTPA, DMSA, Disida, Phitate, S-Coloid, Red Blood Cells In-Vivo, Red Blood Cells In-Vitro) and 4 labelled compounds ( DMSA-Tc99m, DTPA-Tc99m, MIBG-I131, EDTMP-Sm153 ). In the near future the number of items will be increased with new reactor and cyclotron products. Our production system will be certified by ISO 9000 on March 2003. CCHEN is interested in being a national and an international supplier of these products (RS)

  8. NTP Radioisotopes SOC Ltd

    International Nuclear Information System (INIS)

    Letule, T.

    2017-01-01

    NTP Radioisotopes SOC Ltd, a wholly owned subsidiary of the South African Nuclear Energy Corporation (NECSA). Supplies around 20% of the world's medical radioisotopes used. NTP is a pioneer in the introduction and growth of nuclear medicine as in South Africa. Nuclear medicine is the medical specialty that involves the use of radioactive isotopes in the diagnosis and treatment of diseases. Nuclear medicine contributes to enhancing the lives of the society. There is a compelling need for nuclear medicine to be promoted and utilized in the rest of Africa, due to the increasing prevalence of cancer. Cancer is rapidly becoming a public health crisis in low-income and middle-income countries. In sub-Saharan Africa, patients often present with advanced disease

  9. The law concerning prevention from radiation hazards due to radioisotopes

    International Nuclear Information System (INIS)

    1984-01-01

    The law regulates uses, sales and disposal of radioisotopes, uses of radiation generating apparatuses, disposal of materials contaminated with radioisotopes, and so on, in accordance with the Atomic Energy Fundamental Act, for public safety. Covered are the following: permission for and notification of the uses and permission for businesses selling and disposing of radioisotopes, and approval of designs concerning radiation hazard prevention mechanisms, obligations of the users and business enterprises selling and disposing of radioisotopes, the licensed engineers of radiation, organs, etc. for confirmation of the mechanisms, punitive provisions, and so on. (Mori, K.)

  10. Radioisotope techniques in oil wells

    International Nuclear Information System (INIS)

    Jain, Prabuddha

    1998-01-01

    Radioisotope techniques are quite useful in oil exploration and exploitation. Nuclear logging offers a way of gathering information on porosity, permeability, fluid saturations, hydrocarbon types and lithology. Some of the interesting applications in well drilling are determining depth of filtrate invasion, detection of lost circulation, drill-bit erosion control; primary cement measurements and well completions such as permanent tubular markers, perforation position marking, detection of channeling behind casing and gravel pack operations. Radioisotopes have been successfully used in optimizing production processes such as production profiling injection profiling, corrosion measurements and well to well tracer tests. (author)

  11. Cost-benefit aspects of radioisotope methods

    International Nuclear Information System (INIS)

    Jankowski, L.

    1986-01-01

    The cost-benefit relations in the complex application of radioisotpe techniques increased in the last years to up to 1/10 to 1/15. The most essential cause of this trend is the increase of the capacity of production processes, controlled and automatized by means of radioisotopes, and the solution of qualitatively new technological problems of a high economic relevance. A collection of statistical data about the expediture and benefit of different radioisotopes techniques is presented. (author)

  12. Radioisotope tracers in industrial flow studies

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    The scope of radioisotope tracer work carried out by ANSTO has involved most sectors of Australian industry including iron and steel coal, chemical, petrochemical, natural gas, metallurgical, mineral, power generation, liquified air plant, as well as port authorities, water and sewerage instrumentalities, and environmental agencies. A major class of such studies concerns itself with flow and wear studies involving industrial equipment. Some examples are discussed which illustrate the utility of radioisotope tracer techniques in these applications

  13. Economic Contributions of Radioisotope Production Reactor in Korea

    International Nuclear Information System (INIS)

    Nam, Ji Hee; Kim, Seung Su; Moon, Kee Whan

    2010-01-01

    Radioisotopes (RIs) have been used extensively in the fields of industrial, the agricultural, and the medical applications. Especially the deficiency of radioisotopes such as Mo-99 and I-131 in the medical applications recently is becoming the main issue in our society. Radioisotope with the characteristics of public goods in some aspects is mainly playing as the intermediate inputs or goods in the process of the industrial production, with being expected to produce the economic benefits by creating the new demand in the market or enlarging the value added for the related goods and services. In this study, the contribution effects for Korean economy by the construction and operation of the reactor for radioisotope production would be evaluated the effects produced by the activities such as a RI supplies into domestic industry, the RI exports, the neutron transmutation doping services called NTD, and the exports of RI production reactors

  14. Over-all accuracy of sup(99m)Tc-pertechnetate brain scanning for brain tumours

    International Nuclear Information System (INIS)

    Bjoernsson, O.G.; Petursson, E.; Sigurbjoernsson, B.; Davidsson, D.

    1978-01-01

    A 3-year follow-up and re-evaluation of all scans on all patients referred for brain scanning in Iceland during 1 year was performed in order to assess the diagnostic reliability of radioisotope scanning for brain tumours. The study included 471 patients. Of these 25 had primary brain tumours and 7 brain metastases. Scans were positive and correctly interpreted in 68% of the patients with primary brain tumours and in 3 of the 7 patients with metastases. The over-all accuracy of brain scanning for brain tumours defined as the total number of correct positive scans and correct negative scans versus total number of scans examined was 96%, this figure being mainly influenced by the high number of true negative scans. (orig.) [de

  15. Trends in the development of radioisotope batteries

    International Nuclear Information System (INIS)

    Goeldner, R.; Leonhardt, J.W.; Radmaneche, R.; Schlegel, H.

    1978-01-01

    Improved methods for producing radioisotopes by nuclear fuel reprocessing and the rapid development of microelectronics offer new possibilities for utilizing radioisotope batteries. A review is given of the main principles of conversion of decay energy into electric power. The current state of such energy sources is evaluated. Finally, new fields of application and further trends in the development are indicated. (author)

  16. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  17. Organic synthesis with short-lived positron-emitting radioisotopes

    International Nuclear Information System (INIS)

    Pike, V.W.

    1988-01-01

    Chemistry with short-lived positron-emitting radioisotopes of the non-metals, principally 11 C, 13 N and 18 F, has burgeoned over the last decade. This has been almost entirely because of the emergence of positron emission tomography (PET) as a powerful non-invasive technique for investigating pathophysiology in living man. PET is essentially an external technique for the rapid serial reconstruction of the spatial distribution of any positron-emitting radioisotope that has been administered in vivo. Such a distribution is primarily governed by the chemical form in which the positron-emitting radioisotope is incorporated, and importantly for clinical research, is often perturbed by physical, biological or clinical factors. Judicious choice of the chemical form enables specific biological information to be obtained. For example, the labelling of glucose with a positron-emitting radioisotope could be expected to provide a radiopharmaceutical for the study of glucose utilisation in both health and disease. (author)

  18. Diffusion of Implanted Radioisotopes in Solids

    CERN Multimedia

    2002-01-01

    Implantation of radioisotopes into metal and semiconductor samples is performed. The implanted isotope or its decay-product should have a half-life long enough for radiotracer diffusion experiments. Such radioisotopes are utilized to investigate basic diffusion properties in semiconductors and metals and to improve our understanding of the atomic mechanisms of diffusion. For suitably chosen systems the combination of on-line production and clean implantation of radioisotopes at the ISOLDE facility opens new possibilities for diffusion studies in solids. \\\\ \\\\ The investigations are concentrated on diffusion studies of $^{195}$Au in amorphous materials. The isotope $^{195}$Au was obtained from the mass 195 of the mercury beam. $^{195}$Hg decays into $^{195}$Au which is a very convenient isotope for diffusion experiments. \\\\ \\\\ It was found that $^{195}$Au is a slow diffusor in amorphous Co-Zr alloys, whereas Co is a fast diffusor in the same matrix. The ``asymmetry'' in the diffusion behaviour is of considerab...

  19. Radioisotope production in fusion reactors

    International Nuclear Information System (INIS)

    Engholm, B.A.; Cheng, E.T.; Schultz, K.R.

    1986-01-01

    Radioisotope production in fusion reactors is being investigated as part of the Fusion Applications and Market Evaluation (FAME) study. /sup 60/Co is the most promising such product identified to date, since the /sup 60/Co demand for medical and food sterilization is strong and the potential output from a fusion reactor is high. Some of the other radioisotopes considered are /sup 99/Tc, /sup 131/l, several Eu isotopes, and /sup 210/Po. Among the stable isotopes of interest are /sup 197/Au, /sup 103/Rh and Os. In all cases, heat or electricity can be co-produced from the fusion reactor, with overall attractive economics

  20. Radioisotopes production for applications on the health

    International Nuclear Information System (INIS)

    Monroy G, F.; Alanis M, J.

    2010-01-01

    In the Radioactive Materials Department of the Instituto Nacional de Investigaciones Nucleares (ININ) processes have been studied and developed for the radioisotopes production of interest in the medicine, research, industry and agriculture. In particular five new processes have been developed in the last 10 years by the group of the Radioactive Materials Research Laboratory to produce: 99 Mo/ 99m Tc and 188 W/ 188 Re generators, the radio lanthanides: 151 Pm, 147 Pm, 161 Tb, 166 Ho, 177 Lu, 131 I and the 32 P. All these radioisotopes are artificial and they can be produced in nuclear reactors and some of them in particle accelerators. The radioisotope generators are of particular interest, as those of 99 Mo/ 99m Tc and 188 W/ 188 Re presented in this work, because they are systems that allow to produce an artificial radioisotope of interest continually, in these cases the 99m Tc and the 188 Re, without the necessity of having a nuclear reactor or an particle accelerator. They are compact systems armored and sure perfectly of manipulating that, once the radioactive material has decayed, they do not present radiological risk some for the environment and the population. These systems are therefore of supreme utility in places where it is not had nuclear reactors or with a continuous radioisotope supply, due to their time of decaying, for its cost or for logistical problems in their supply, like it is the case of many hospital centers, of research or industries in our country. (Author)

  1. Radioisotope applications in petroleum and gas industries

    International Nuclear Information System (INIS)

    Castagnet, A.C.; Agudo, E.G.; Duarte, U.

    1974-01-01

    The principal radioisotopic technique used for studying and /or controling the drilling, completion, treatment and oil well secondary recovery operations are described. In this cases the radioisotopes are employed almost exclusively as 'markers', in the form of localized and dispersed tracers. The growing acceptance of these techniques is essentially, a consequence of the confidence in the reliability of the data and conclusions derived from their application

  2. Production and application of radioisotopes - a Canadian perspective

    International Nuclear Information System (INIS)

    O'Neill, W.P.; Evans, D.J.R.

    1988-01-01

    This paper outlines the historical evolutions of radioisotopes from first concepts and discoveries to significant milestones in their production and the development of applications throughout the world. Regarding production, it addresses the methods that have been used at various stages during this evolution outlining the important findings that have led to further developments. With respect to radioisotope applications, the paper addresses the development of markets in industry, medicine, and agriculture and comments on the size of these markets and their rate of growth. Throughout, the paper highlights the Canadian experience and it also presents a Canadian view of emerging prospects and a forecast of how the future for radioisotopes might develop

  3. Future radioisotope power needs for missions to the solar system

    International Nuclear Information System (INIS)

    Mondt, J.F.; Underwood, M.L.; Nesmith, B.J.

    1997-01-01

    NASA and DOE plan a cooperative team effort with industry, government laboratories and universities to develop a near term, low cost, low power (100 watt electric class), low mass (<10 kg), advanced radioisotope space power source (ARPS) and in the process reduce the plutonium-related costs as well. The near term is focused on developing an advanced energy converter to use with the General Purpose Heat Source (GPHS). The GPHS was developed and used for the current radioisotope thermoelectric generators (RTGs). Advanced energy converter technologies are needed as a more efficient replacement for the existing thermoelectric converters so that the space radioisotope power source mass and cost can be reduced. a more advanced technology space radioisotope power system program is also planned that addresses a longer-term need. Twenty first century robotic scientific information missions to the outer planets and beyond are planned to be accomplished with microspacecraft which may demand safe, even more compact, lower-power, lower-mass radioisotope power sources than those which can be achieved as a result of the near term efforts. The longer-term program focuses not only on converter technology but also on lower power, more compact radioisotope heat source technology and smaller, lower mass radioisotope heater units for second generation microspacecraft. This more ambitious, longer time-horizon focus necessarily occurs at this time on the technology R and D level rather than at the system technology level

  4. Radiation safety practice in Sudan with respect to industrial radioisotope applications

    International Nuclear Information System (INIS)

    Ahmed, W.D.; Hassan, B.A.; Zeada, D.O.M.; Sirelkhatim, D.A.; Salih, S.A.; Hassan, M.S.

    2008-06-01

    The use of radioisotope technology in petrochemical industry in Sudan started in 2003, since then gamma scanning for distillation columns and tracer applications for leak detection was performed 6 times at a refinery 60 Km away from Khartoum, by Sudan Atomic Energy Commission II T group. This paper focuses on safety and radiation protection for this practice, also describes safety requirements, the emergency plan and evaluation of dose worker value which was done on these missions. The assessment of worker's doses performed showed that they are within an acceptable range. Recommendations are made to even bring them lower. The paper also sheds light on some problems raised and suggests remedial actions.(Author)

  5. Scanning technology selection impacts acceptability and usefulness of image-rich content

    Directory of Open Access Journals (Sweden)

    Kristine M. Alpi

    2016-01-01

    Full Text Available Objective: Clinical and research usefulness of articles can depend on image quality. This study addressed whether scans of figures in black and white (B&W, grayscale, or color, or portable document format (PDF to tagged image file format (TIFF conversions as provided by interlibrary loan or document delivery were viewed as acceptable or useful by radiologists or pathologists. Methods: Residency coordinators selected eighteen figures from studies from radiology, clinical pathology, and anatomic pathology journals.With original PDF controls, each figure was prepared in three or four experimental conditions: PDF conversion to TIFF, and scans from print in B&W, grayscale, and color. Twelve independent observers indicated whether they could identify the features and whether the image quality was acceptable. They also ranked all the experimental conditions of each figure in terms of usefulness. Results: Of 982 assessments of 87 anatomic pathology, 83 clinical pathology, and 77 radiology images, 471 (48% were unidentifiable. Unidentifiability of originals (4% and conversions (10% was low. For scans, unidentifiability ranged from 53% for color, to 74% for grayscale, to 97% for B&W. Of 987 responses about acceptability (n¼405, 41% were said to be unacceptable, 97% of B&W, 66% of grayscale, 41% of color, and 1% of conversions. Hypothesized order (original, conversion, color, grayscale, B&W matched 67% of rankings (n¼215. Conclusions: PDF to TIFF conversion provided acceptable content. Color images are rarely useful in grayscale (12% or B&W (less than 1%. Acceptability of grayscale scans of noncolor originals was 52%. Digital originals are needed for most images. Print images in color or grayscale should be scanned using those modalities.

  6. Scanning Capacitance Microscopy | Materials Science | NREL

    Science.gov (United States)

    obtained using scanning capacitance microscopy. Top Right: Image of p-type and n-type material, obtained 'fingers' of light-colored n-type material on a yellow and blue background representing p-type material material, obtained using scanning capacitance microscopy, in a sample semiconductor device; the image shows

  7. Random-process excursions in radioisotope instruments

    International Nuclear Information System (INIS)

    Galochkin, D.V.; Polovko, S.A.

    1984-01-01

    Approximate expressions are derived for the mathematical expectation, variance, and distribution of the durations of the excursions of the output signal from a ratemeter in a radioisotope relay instrument. The tabulated comparison of results from Monte Carlo simulation and analytical calculation shows good agreement over the mean value and the variance of the excursion duration for T 0.2 sec as calculated and as obtained by Monte Carlo simulation with a computer using 5000 realizations. It is suggested that the results should be used in choosing the optimum parameters of radioisotope relay instruments

  8. Ventilation-perfusion scans in neonatal regional pulmonary emphysema complicating ventilatory assistance

    International Nuclear Information System (INIS)

    Leonidas, J.C.; Moylan, F.M.B.; Kahn, P.C.; Ramenofsky, M.L.

    1978-01-01

    Two cases of ventilator-related neonatal lobar overexpansion with similar radiographic appearance, but probably different pathogenesis, are presented. In one infant, persistent interstitial lobar emphysema was confirmed by markedly decreased perfusion shown on scintigraphy; this information was of great value in predicting the beneficial effect of lobectomy. In the other case, ventilation and perfusion scans indicated functional value of the emphysematous lobe and correctly suggested conservative management. Radioisotope lung scans may provide valuable information regarding lung function in regional pulmonary emphysema associated with assisted ventilation in neonatal respiratory distress syndrome, and thus determine patient management

  9. Daily intakes of naturally occurring radioisotopes in typical Korean foods

    International Nuclear Information System (INIS)

    Choi, Min-Seok; Lin Xiujing; Lee, Sun Ah; Kim, Wan; Kang, Hee-Dong; Doh, Sih-Hong; Kim, Do-Sung; Lee, Dong-Myung

    2008-01-01

    The concentrations of naturally occurring radioisotopes ( 232 Th, 228 Th, 230 Th, 228 Ra, 226 Ra, and 40 K) in typical Korean foods were evaluated. The daily intakes of these radioisotopes were calculated by comparing concentrations in typical Korean foods and the daily consumption rates of these foods. Daily intakes were as follows: 232 Th, 0.00-0.23; 228 Th, 0.00-2.04; 230 Th, 0.00-0.26; 228 Ra, 0.02-2.73; 226 Ra, 0.01-4.37 mBq/day; and 40 K, 0.01-5.71 Bq/day. The total daily intake of the naturally occurring radioisotopes measured in this study from food was 39.46 Bq/day. The total annual internal dose resulting from ingestion of radioisotopes in food was 109.83 μSv/y, and the radioisotope with the highest daily intake was 40 K. These values were same level compiled in other countries

  10. Critical study of the diagnostic value of lung scans using 67 gallium in respiratory diseases

    International Nuclear Information System (INIS)

    Perrin-Fayolle, M.; Brun, J.; Moret, R.; Kofman, J.; Ortonne, J.P.; Petigny, C.

    1975-01-01

    70 lungs scans using gallium 67 were carried out. Among the 41 malignant lesions, an uptake of the radio-isotope by the tumour in 51% of cases was noted. Among the 29 benign lesions, there were also 34% of cases which took up gallium 67. Their lack of reliability and selectivity make gallium 67 lung scans unsuitable for the recognition of the malignant nature of lung diseases [fr

  11. Radioisotopes as Political Instruments, 1946–1953

    Science.gov (United States)

    Creager, Angela N. H.

    2009-01-01

    The development of nuclear “piles,” soon called reactors, in the Manhattan Project provided a new technology for manufacturing radioactive isotopes. Radioisotopes, unstable variants of chemical elements that give off detectable radiation upon decay, were available in small amounts for use in research and therapy before World War II. In 1946, the U.S. government began utilizing one of its first reactors, dubbed X-10 at Oak Ridge, as a production facility for radioisotopes available for purchase to civilian institutions. This program of the U.S. Atomic Energy Commission was meant to exemplify the peacetime dividends of atomic energy. The numerous requests from scientists outside the United States, however, sparked a political debate about whether the Commission should or even could export radioisotopes. This controversy manifested the tension in U.S. politics between scientific internationalism as a tool of diplomacy, associated with the aims of the Marshall Plan, and the desire to safeguard the country’s atomic monopoly at all costs, linked to American anti-Communism. This essay examines the various ways in which radioisotopes were used as political instruments—both by the U.S. federal government in world affairs, and by critics of the civilian control of atomic energy—in the early Cold War. PMID:20725612

  12. Application of radiation and radioisotopes in life science

    International Nuclear Information System (INIS)

    Nakanishi, Tomoko M.

    2005-01-01

    Radiation and Radioisotopes have been played an important role in the wide range of life science, from the field study, such as fertilizer or pesticide development or production of new species, to gene engineering researches. Many mutants through radiation have been provided to the market and the usage of radioactive tracers was an effective tool to study plant physiology. It has been granted that the contribution of radioisotopes has been accelerated the development of the gene engineering technology, which is now overwhelming all the other usages of radiation or radioisotopes. However, because of the difficulty to get social acceptance for gene modified plants, the orientation of the life science is now changing towards, so called ''post genome era''. Therefore, from the point of radiation or radioisotope usage, new application methods are needed to develop new type of researches. We present how (1) neutron activation analysis, (2) neutron radiography and (3) positron emission tomography are promising to study living plant physiology. Some of these techniques are not necessarily new methods but with a little modification, they show new aspects of plant activity. (author)

  13. Radioisotopes - where have we got to, where are we going ?

    International Nuclear Information System (INIS)

    Taylor, C.B.G.

    1986-01-01

    Rapid growth has been achieved and there are remarkable possibilities in various fields of radioisotopes and radiation. New applications in molecular biology, in nuclear medicine, and in biotechnology are opening further opportunities for the use of radioisotopes. In the industrial field too there is growth, as microprocessor techniques extend the usefulness of radioisotope methods. And radiation engineering is a success story of its own, as ever-increasing use is made of radiation processing and sterilization, and new horizons open for food irradiation. This paper begins by recalling how isotope technology developed from the research laboratory to become the industry-scale activity it is today. A section is devoted to describing the development of a new radioisotope industry during the period from the 1930s through 1960s, focusing on the growth in the areas of nuclear medicine, radiotherapy, isotope gauging and tracing, production control, industrial processing, and production of radioisotopes. After a brief review of the present it looks into the future to suggest the directions in which new developments may lie. In particular, remarkable growth is expected in such areas as molecular biology, biotechnology, radiography, gauging, process control, radiation processing, and radiation sterilization. A review is also made of the transport and disposal of radioisotopes. (Nogami, K.)

  14. Production of radioisotopes with BR2 facilities

    International Nuclear Information System (INIS)

    Fallais, C.J.; Morel de Westfaver, A.; Heeren, L.; Baugnet, J.M.; Gandolfo, J.M.; Boeykens, W.

    1978-01-01

    After a brief account on the isotopes production evolution in the industrialized countries the irradiation devices and the types of standardized capsules used in the BR2 reactor are described as well as the thermal neutron flux. Production of most important radioisotopes like 131 Iodine, 60 Cobalt, 192 Iridium and 99 Molybdenum and their main utilizations (uses)are described. The mean specific activities and the limit of use for different radioisotopes are reported. (A.F.)

  15. Advanced Radioisotope Power Systems Segmented Thermoelectric Research

    Science.gov (United States)

    Caillat, Thierry

    2004-01-01

    Flight times are long; - Need power systems with >15 years life. Mass is at an absolute premium; - Need power systems with high specific power and scalability. 3 orders of magnitude reduction in solar irradiance from Earth to Pluto. Nuclear power sources preferable. The Overall objective is to develop low mass, high efficiency, low-cost Advanced Radioisotope Power System with double the Specific Power and Efficiency over state-of-the-art Radioisotope Thermoelectric Generators (RTGs).

  16. Work Began on Contracts for Radioisotope Power Conversion Technology Research and Development

    Science.gov (United States)

    Wong, Wayne A.

    2005-01-01

    NASA has had a history of successful space flight missions that depended on radioisotope-fueled power systems. These Radioisotope Power Systems (RPSs) converted the heat generated from the decay of radioisotope material into useful electrical power. An RPS is most attractive in applications where photovoltaics are not optimal, such as deep-space applications where the solar flux is too low or extended applications on planets such as Mars where the day/night cycle, settling of dust, and life requirements limit the usefulness of photovoltaics. NASA s Radioisotope Power Conversion Technology (RPCT) Program is developing next-generation power-conversion technologies that will enable future missions that have requirements that cannot be met by the two RPS flight systems currently being developed by the Department of Energy for NASA: the Multi-Mission Radioisotope Thermoelectric Generator and the Stirling Radioisotope Generator (SRG).

  17. Reactor production and processing of radioisotopes for therapeutic applications in nuclear medicine

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Mirzadeh, S.; Beets, A.L.

    1995-01-01

    Nuclear reactors continue to play an important role in providing radioisotopes for nuclear medicine. Many reactor-produced radioisotopes are ''neutron rich'' and decay by beta-emission and are thus of interest for therapeutic applications. This talk discusses the production and processing of a variety of reactor-produced radioisotopes of current interest, including those produced by the single neutron capture process, double neutron capture and those available from beta-decay of reactorproduced radioisotopes. Generators prepared from reactorproduced radioisotopes are of particular interest since repeated elution inexpensively provides many patient doses. The development of the alumina-based W-188/Re-188 generator system is discussed in detail

  18. Control of radioisotopes and radiation sources in Indonesia

    International Nuclear Information System (INIS)

    Ridwan, M.

    2001-01-01

    Radioisotopes and radiation sources are extensively used in Indonesia in medicine, industry, mining, agriculture and research. These materials are controlled by the regulatory authority, according to established legal procedures. The Nuclear Energy Control Board of Indonesia (BAPETEN), which was established in 1998 through the Nuclear Energy Act No. 10/1997, is entrusted with the control of any application of nuclear energy, including the application of radioisotopes and radiation sources, through regulation, licensing and inspection. The control is aimed to assure welfare, security and peace, the safety and health of workers and the public, and environmental protection. The number of licences issued to date is around 2400, consisting of 1600 licences for radioisotopes and radiation sources used in hospitals, 347 in radiography, 256 in industry, 53 in mining, and the rest in many other areas such as research and agriculture. A licence can cover one or more radioisotopes or radiation sources, depending on the location of the user institution. These radioisotopes and radiation sources are Co-60, Cs-137, Ir-192, Ra-226, Am-241, Sr-90, Kr-85, Pm-147, linear accelerator and X-ray, and short half-life radioisotopes such as I-125, I-131 and Tc-99m. There are 10 LINACs, 27 X-ray medicines, 61 radioisotope devices for Co-60 and Cs-137, and 10 mHDR Ir-192 for therapeutic purposes currently used in Indonesia and some Ra-226 in storage. Any activity related to the application of nuclear energy is required to be conducted in a manner which observes safety and security. According to the legal requirements, each user has to employ at least one radiation safety officer. To improve the control of the application of radiation sources and radioactive material in the country, BAPETEN introduced some new approaches to the users, including regular dialogues with radiation safety officers and the management of the users, requalification for radiation protection officers twice in five

  19. New Directions In Radioisotope Spectrum Identification

    International Nuclear Information System (INIS)

    Salaymeh, S.; Jeffcoat, R.

    2010-01-01

    Recent studies have found the performance of commercial handheld detectors with automatic RIID software to be less than acceptable. Previously, we have explored approaches rooted in speech processing such as cepstral features and information-theoretic measures. Scientific advances are often made when researchers identify mathematical or physical commonalities between different fields and are able to apply mature techniques or algorithms developed in one field to another field which shares some of the same challenges. The authors of this paper have identified similarities between the unsolved problems faced in gamma-spectroscopy for automated radioisotope identification and the challenges of the much larger body of research in speech processing. Our research has led to a probabilistic framework for describing and solving radioisotope identification problems. Many heuristic approaches to classification in current use, including for radioisotope classification, make implicit probabilistic assumptions which are not clear to the users and, if stated explicitly, might not be considered desirable. Our framework leads to a classification approach with demonstrable improvements using standard feature sets on proof-of-concept simulated and field-collected data.

  20. KAERI's challenge to steady production of radioisotopes and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Park, J.H.; Han, H.S.; Park, K.B.

    2000-01-01

    The Korea Atomic Energy Research Institute (KAERI) is a national organization in Korea, and has been doing many research and development works in radioisotope production and applications for more than 30 years. Now KAERI regularly produces radioisotopes (I-131, Tc-99m, Ho-166) for medical use and Ir-192 for industrial use. Various I-131 labeled compounds and more than 10 kinds of Tc-99m cold kits are also produced. Our multi-purpose reactor, named HANARO, has been operative since April of 1995. HANAKO is an open tank type reactor with 30 MW thermal capacity. This reactor was designed not only for research on neutron utilization but for production of radioisotopes. KAERI intended to maximize the radioisotope production capability. For this purpose, radioisotope production facilities (RIPF) have been constructed adjacent to the HANARO reactor building. There are four banks of hot cells equipped with manipulators and some of the hot cells were installed according to the KGMP standards and with clean rooms. In reviewing our RI production plan intensively, emphasis was placed on the development of new radiopharmaceuticals, development of new radiation sources for industrial and therapeutic use, and steady production of selected radioisotopes and radiopharmaceuticals. The selected items are Ho-166 based pharmaceuticals, fission Mo-99/Tc-99m generators. solution and capsules of I-131, and Ir-192 and Co-60 for industrial use. The status and future plan of KAERI's research and development program will be introduced, and will highlight programs for steady production. (author)

  1. Radioisotopes in Hydrology. Proceedings of a Symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-08-15

    The increasing emphasis on the development of water resources poses problems which are of interest to all countries, both developing and advanced, where the demand for water is continuously rising. There is no doubt that greater efforts must be made to evaluate, control and develop water resources using all scientific means available and during recent years increasing attention has been directed to the supplementation of hydrological methods with radioisotope techniques. These techniques have already been applied to a number of problems and their potential usefulness demonstrated. Radioisotopes can be used for stream discharge measurements with an accuracy as good as that obtainable with conventional methods. They are also finding increasing application in the measurement of groundwater direction and velocity, the study of suspected interconnections between different sources of water, and the investigation of mixing processes in rivers and lakes. Radioisotope techniques have been used in different parts of the world for studying the transport of silt in rivers and harbours. Present research is directed towards making these investigations on a quantitative basis which, if successful, would be of great importance in the design of hydraulic structures. The method of finding out the age of groundwater by measuring its natural tritium content can be applied to the determination of the recharge rate of groundwater bodies, so enabling a more rational use of the groundwater reserves without fear of overexploitation. Current research is aimed at using carbon-14 for groundwater-dating to extend the age measurable by tritium. A Symposium on the use of radioisotopes in hydrology was organized by the Agency and held in March 1963 in Tokyo in co-operation with the Japanese Government, for whose material and other assistance and generous hospitality the Agency wishes to record its grateful appreciation. The Symposium was attended by about 100 participants from 14 countries and 5

  2. The Use of Color-Coded Duplex Scanning in the Selection of Patients with Lower Extremity Arterial Disease for Percutaneous Transluminal Angioplasty: A Prospective Study

    International Nuclear Information System (INIS)

    Elsman, Bernard H.P.; Legemate, Dink A.; Heyden, Frank W.H.M. van der; Vos, Henk de; Mali, Willem P.T.M.; Eikelboom, Bert C.

    1996-01-01

    Purpose: To exploit the potential benefits of percutaneous transluminal angioplasty (PTA) in patients with short obstructive lesions in the lower extremity, it is preferable to select patients suitable for PTA before proceeding to hospital admission and angiography. The aim of this prospective study was to evaluate the role of color-coded duplex scanning in the correct selection of patients for PTA and its influence on planning the approach to the lesion. Methods: On the basis of clinical history, physical examination, pressure indices, and ultrasound duplex scanning, 109 patients were scheduled for PTA. Results: The indication for PTA was correct in 103 patients (94%), while the procedure was performed successfully in 98 patients (90%). The approach to the lesion was planned successfully in the majority of patients. Conclusion: This study shows that it is justifiable to plan PTA on the basis of information obtained by duplex scanning. Results of the duplex scan may guide the catheterization route

  3. Application of radioisotope technique for investigation of pumps seals

    International Nuclear Information System (INIS)

    Antoszewski, B.; Zorawska, A.

    1988-01-01

    Radioisotope method of measuring the wear of rings of the face mechanical seals, bush in soft seals, and leakage in double mechanical seals is described. The examples are given. It is found that radioisotope technique can be used for investigation of the seals. (author)

  4. Studies on application of radiation and radioisotopes

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Lee, Ji Bok; Lee, Yeong Iil; Jin, Joon Ha; Beon, Myeong Uh; Park, Kyeong Bae; Han, Heon Soo; Jeong, Yong Sam; Uh, Jong Seop; Kang, Kyeong Cheol; Cho, Han Ok; Song, Hui Seop; Yoon, Byeong Mok; Jeon, Byeong Jin; Park, Hong Sik; Kim, Jae Seong; Jeong, Un Soo; Baek, Sam Tae; Cho, Seong Won; Jeon, Yeong Keon; Kim, Joon Yeon; Kwon, Joong Ho; Kim, Ki Yeop; Yang, Jae Seung; No, Yeong Chang; Lee, Yeong Keun; Shin, Byeong Cheol; Park, Sang Joon; Hong, Kwang Pyo; Cho, Seung Yeon; Kang, Iil Joon; Cho, Seong Ki; Jeong, Yeong Joo; Park, Chun Deuk; Lee, Yeong Koo; Seo, Chun Ha; Han, Kwang Hui; Shin, Hyeon Young; Kim, Jong Kuk; Park, Soon Chul; Shin, In Cheol; Lee, Sang Jae; Lee, Ki Un; Lim, Yong Taek; Park, Eung Uh; Kim, Dong Soo; Jeon, Sang Soo

    1993-05-01

    With the completion of construction of KMRR, the facility and technology of radiation application will be greatly improved. This study was performed as follows; (1) Studies on the production and application of radioisotopes. (2) The development of radiation processing technology. (3) The application of Irradiation techniques for food preservation and process improvement. (4) Studies on the radiation application for the development of genetic resources (5) Development of the radioisotope (RI) production facilities for Korea Multipurpose Research Reactor (KMRR)

  5. Safety regulations for radioisotopes, etc. (interim report)

    International Nuclear Information System (INIS)

    1980-01-01

    An (interim) report by an ad hoc expert committee to the Nuclear Safety Commission, on the safety regulations for radioisotopes, etc., was presented. For the utilization of radioisotopes, etc., there is the Law Concerning Prevention of Radiation Injury Due to Radioisotopes, etc. with the advances in this field and the improvement in international standards, the regulations by the law have been examined. After explaining the basic ideas of the regulations, the problems and countermeasures in the current regulations are described: legal system, rationalization in permission procedures and others, inspection on RI management, the system of the persons in charge of radiation handling, RI transport, low-level radioactive wastes, consumer goods, definitions of RIs, radiation and sealed sources, regulations by group partitioning, RI facilities, system of personnel exposure registration, entrusting of inspection, etc. to private firms, and reduction in the works for permission among governmental offices. (author)

  6. Radioisotope Power Systems Technology Development

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the RPS's technology portfolio is to advance performance of radioisotope power systems through new and novel innovations being developed and transitioned...

  7. Multicolor Scanning Laser Imaging in Diabetic Retinopathy.

    Science.gov (United States)

    Ahmad, Mohammad S Z; Carrim, Zia Iqbal

    2017-11-01

    Diabetic retinopathy is a common cause of blindness in individuals younger than 60 years. Screening for retinopathy is undertaken using conventional color fundus photography and relies on the identification of hemorrhages, vascular abnormalities, exudates, and cotton-wool spots. These can sometimes be difficult to identify. Multicolor scanning laser imaging, a new imaging modality, may have a role in improving screening outcomes, as well as facilitating treatment decisions. Observational case series comprising two patients with known diabetes who were referred for further examination after color fundus photography revealed abnormal findings. Multicolor scanning laser imaging was undertaken. Features of retinal disease from each modality were compared. Multicolor scanning laser imaging provides superior visualization of retinal anatomy and pathology, thereby facilitating risk stratification and treatment decisions. Multicolor scanning laser imaging is a novel imaging technique offering the potential for improving the reliability of screening for diabetic retinopathy. Validation studies are warranted.

  8. RSG-Gas Based Radioisotopes And Sharing Program For Regional Back Up Supply

    International Nuclear Information System (INIS)

    Soenardjo, Sunarhadijoso; Tamat, Swasono R.; Suparman, Ibon; Purwadi, Bambang

    2003-01-01

    As the owner of the reactors used for radioisotope production, BATAN needs to increase the effectiveness of the reactor operation cost that can be achieved by simultaneously exploiting all the existing irradiation facility, supported by full utilization of the radioisotopes produced. On the other hand, the domestic demand of radioisotopes is much lower than the production capability but sometimes the request is compulsory to be suspended due to reactor operation schedule. As this condition is mostly similar to that of several countries of RCA Member States, a sharing program for regional back up supply seems to be a positive thought to support expectation on the effectiveness of reactor operation cost and the continuity of radioisotope product services as well as the utilization of radioisotopes produced. Based on radioactivity achieved in each production batch at the present, 131 I, 99 Mo, 153 Sm, 125 I and 32 p radioisotopes may be offered for back up supply program. Due to consideration on conformity of user demands with reactor operation and radiochemical processing costs, the concept of back up supply program should performed first by means of full utilization of the available products and not by increasing reactor operation frequency. An information and communication network system, therefore, is absolutely needed to support information exchange between the radioisotope producer, members of back up supply program and radioisotope customers

  9. Radioisotopic heat source

    Science.gov (United States)

    Jones, G.J.; Selle, J.E.; Teaney, P.E.

    1975-09-30

    Disclosed is a radioisotopic heat source and method for a long life electrical generator. The source includes plutonium dioxide shards and yttrium or hafnium in a container of tantalum-tungsten-hafnium alloy, all being in a nickel alloy outer container, and subjected to heat treatment of from about 1570$sup 0$F to about 1720$sup 0$F for about one h. (auth)

  10. Study on the status of radiation/radioisotope utilization during the last 5 years

    International Nuclear Information System (INIS)

    Lee, Yun Jong; Park, Tae Jin; Kuk, Il Hiun

    2007-01-01

    The objectives of this study is derivation of important indices for establishing government policy to promote radiation and radioisotope utilization and for setting up effective strategy o develop related industries, on the basis of utilization data, and deduction of economic scale induced by using radiation and radioisotope, through the analysis of economic contribution by multi-variate model. Uses of radiation and radioisotopes are increasing annually in Korea, and the effect of utilization to economy and industry is continuously enlarged in accordance with technology development and expansion of radiation and radioisotope uses. Indices related to radiation nd radioisotope uses, which are useful for the promotion of utilization and establishment of development strategy, have to be derived and updated every year. Important indices related to radiation and radioisotope utilization are derived through the study. The indices are useful for planning establishing, and revising policies to promote radiation and radioisotope utilization, and re furthermore valuable for public acceptance nuclear energy

  11. Hygienic efficiency of radioisotope instruments application in motor-car industry

    International Nuclear Information System (INIS)

    Tolokonnikov, M.I.; Lev, M.Ya.; Liberman, A.N.; Chictov, E.D.

    1978-01-01

    At the Moscow Automobile Works named after I.A. Likhachev, an analysis was made of the hygienic and technologic-economic benefits from use of radioisotope instruments. Radioisotopic sources of radiation are used for research and measuring purposes in various automatic control and monitoring systems, and in evaluating the effectiveness of cleaning facilities. The application of radioisotopic instruments contributes to achieving the maximum possible efficiency of the equipment, to the improvement of working conditions, and to the prevention of environmental pollution

  12. A report on the extent of radioisotope usage in Malaysia

    International Nuclear Information System (INIS)

    1983-04-01

    A market survey was carried out to study the extent of radioisotope usage in Malaysia. From the survey, the radioisotopes and their activities/quantities that are used in Industry, Medicine and Research were identified. The radioisotopes that are frequently needed or routinely used were also determined and this formed the basis of the recommendations put forward in this report. It is proposed that PUSPATI adopt the concept of a Distribution Centre in order to provide a service to the Malaysian community. (author)

  13. The Research and Development of the Radioisotope Energy Conversion System

    International Nuclear Information System (INIS)

    Steinfelds, E.V.; Ghosh, T.K.; Prelas, M.A.; Tompson, R.V.; Loyalka, S.K.

    2001-01-01

    The project of developing radioisotope energy conversion system (RECS) involves analytical computational assisted design and modeling and also laboratory research. The computational analysis consists of selecting various geometries and materials for the main RECS container and the internally located radioisotope, computing the fluxes of the beta (-) particles and of the visible (or ultraviolet) photons produced by the beta (-) s, computing the transport of these photons to the photovoltaic cells, and computing the overall efficiency of useful conversion of the radioisotope power

  14. Personal reflections on the highlights and changes in radiation and radioisotope measurement applications

    International Nuclear Information System (INIS)

    Gardner, Robin P.; Lee, Kyoung O.

    2015-01-01

    This paper describes the recent changes that the authors have perceived in the use of radiation and radioisotope measurement applications. The first change is that due to the increased use of Monte Carlo simulation which has occurred from a normal evolutionary process. This is due in large part to the increased accuracy that is being obtained by the use of detector response functions (DRFs) and the simultaneous increased computational efficiency that has become available with these DRFs, the availability of a greatly improved weight windows variance reduction method, and the availability of inexpensive computer clusters. This first change is a happy one. The other change that is occurring is in response to recent terrorist activities. That change is the replacement or major change in the use of long-lived radioisotopes in radioisotope measurement and other radioisotope source applications. In general this can be done by improving the security of these radioisotope sources or by replacing them altogether by using machine sources of radiation. In either case one would like to preclude altogether or at least minimize the possibility of terrorists being able to obtain radioisotopes and use them for clandestine purposes. - Highlights: • Recent changes in radioisotope measurement applications. • Improvements in Monte Carlo simulation for treating radioisotope measurement applications. • Replacement of radioisotope sources with machine sources of radiation.

  15. Normal variants and artifacts in bone scan: potential for errors in interpretation

    International Nuclear Information System (INIS)

    Sohn, Myung Hee

    2004-01-01

    Bone scan is one of the most frequently performed studies in nuclear medicine. In bone scan, the amount of radioisotope taken up by lesion depends primarily on the local rate of bone turnover rather than on the bone mass. Bone scan is extremely sensitive for detecting bony abnormalities. However, abnormalities that appear on bone scan may not always represent disease. The normal scan appearances may be affected not only by skeletal physiology and anatomy but also by a variety of technical factors which can influence image quality. Many normal variants and artifacts may appear on bone scan. They could simulate a pathologic process and could mislead into the wrong diagnostic interpretation. Therefore, their recognition is necessary to avoid misdiagnosis. A nuclear medicine physician should be aware of variable appearance of the normal variants and artifacts on bone scan. In this article, a variety of normal variants and artifacts mimicking real pathologic lesion in bone scan interpretation are discussed and illustrated

  16. Production of Radioisotopes in Pakistan Research Reactor: Past, Present and Future

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2013-01-01

    Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programs. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. The availability of short-lived radionuclides from radionuclide generators provides an inexpensive and convenient alternative to in-house radioisotope production facilities such as cyclotrons and reactors. The reactor offers large volume for irradiation, simultaneous irradiation of several samples, economy of production and possibility to produce a wide variety of radioisotopes. The accelerator-produced isotopes relatively constitute a smaller percentage of total use. (author)

  17. Technical diagnosis of industrial plants with radioisotopes

    International Nuclear Information System (INIS)

    Hartmann, G.

    1984-01-01

    A survey is given of the application of radioisotopes in technical diagnosis of industrial plants. Proceeding from the economic importance and the state of the art of radioisotope applications, the principles of tracer techniques are outlined including topical examples of application such as passage of coal through a steam generator, wear in impact crashing of coal, wear and corrosion in pipelines, testing the effective cross section of pipes, and investigations of microstructures. Limits and restrictions of applications are briefly discussed

  18. Studies on the production and application of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hyon Soo; Park, K. B.; Kim, J. R.; Yoon, B. M.; Bang, H. S.; Shin, B. C.; Cho, W. K.; Park, U. J.; Park, C. D.; Lee, Y. G.; Suh, C. H.; Shin, H. Y.; Kim, D. S.; Hong, S. B.; Jun, S. S.; Min, E. S.; Jang, K. D.; Kim, J. K.; Kim, S. J.; Yang, S. Y.; Yang, S. H.; Chun, K. J.; Kang, H. Y.; Suh, K. S.; Goo, J. H.; Chung, S. H.; Lee, J. C.; Choi, J. L.; Lee, H. Y.; Bang, K. S.

    1997-09-01

    To produce radioisotopes utilizing the research reactor `HANARO`, development of RI production process, target fabrication, preparation of devices and tools for RI process, preparation of production facility for radiopharmaceuticals, test production for the established process, etc. have been carried out, respectively. Production processes for various kinds of radionuclides were developed and the settled methods were applied to test production using `HANARO`. The results of developed process are as follows: (1) I-131 dry distillation method. (2) Large scale production of Ir-192 sources (3) P-32 production process by distillation under reduced pressure (4) Cr-51 production process using enriched target. To irradiate the target for RI production in `HANARO`, target for neutron irradiation, loading/unloading devices, working table in service pool, remote handling tools, shield cask for irradiated target transfer, etc. were designed and fabricated. The function test of prepared targets and the safety analysis of shielding casks were carried out. License for practical use of the prepared casks were obtained from Ministry of Science and Technology. For production of medical radioisotopes, their production facilities were designed in detail and were installed in RIPF (Radioisotope Production Facility), with full reflection of the basic concept of the good manufacturing practice for radiopharmaceuticals. The constructed GMP facilities have started to be operated after authorization since Jun., 1997. Results of this study will be applied to mass production of radioisotopes in `HANARO` and are to contribute the advance of domestic medicine and industry related to radioisotopes. (author). 7 refs., 7 tabs., 4 figs.

  19. Studies on the production and application of radioisotopes

    International Nuclear Information System (INIS)

    Han, Hyon Soo; Park, K. B.; Kim, J. R.; Yoon, B. M.; Bang, H. S.; Shin, B. C.; Cho, W. K.; Park, U. J.; Park, C. D.; Lee, Y. G.; Suh, C. H.; Shin, H. Y.; Kim, D. S.; Hong, S. B.; Jun, S. S.; Min, E. S.; Jang, K. D.; Kim, J. K.; Kim, S. J.; Yang, S. Y.; Yang, S. H.; Chun, K. J.; Kang, H. Y.; Suh, K. S.; Goo, J. H.; Chung, S. H.; Lee, J. C.; Choi, J. L.; Lee, H. Y.; Bang, K. S.

    1997-09-01

    To produce radioisotopes utilizing the research reactor 'HANARO', development of RI production process, target fabrication, preparation of devices and tools for RI process, preparation of production facility for radiopharmaceuticals, test production for the established process, etc. have been carried out, respectively. Production processes for various kinds of radionuclides were developed and the settled methods were applied to test production using 'HANARO'. The results of developed process are as follows: 1) I-131 dry distillation method. 2) Large scale production of Ir-192 sources 3) P-32 production process by distillation under reduced pressure 4) Cr-51 production process using enriched target. To irradiate the target for RI production in 'HANARO', target for neutron irradiation, loading/unloading devices, working table in service pool, remote handling tools, shield cask for irradiated target transfer, etc. were designed and fabricated. The function test of prepared targets and the safety analysis of shielding casks were carried out. License for practical use of the prepared casks were obtained from Ministry of Science and Technology. For production of medical radioisotopes, their production facilities were designed in detail and were installed in RIPF (Radioisotope Production Facility), with full reflection of the basic concept of the good manufacturing practice for radiopharmaceuticals. The constructed GMP facilities have started to be operated after authorization since Jun., 1997. Results of this study will be applied to mass production of radioisotopes in 'HANARO' and are to contribute the advance of domestic medicine and industry related to radioisotopes. (author). 7 refs., 7 tabs., 4 figs

  20. List of DOE radioisotope customers with summary of radioisotope shipments FY 1978

    International Nuclear Information System (INIS)

    Burlison, J.S.; Laidler, R.I.

    1979-05-01

    The purpose of the document is to list DOE's radioisotopes production and distribution activities by its facilities at Argonne National Laboratory; Pacific Northwest Laboratory; Brookhaven National Laboratory; Hanford Engineering Development Laboratory; Idaho Operations Office; Los Alamos Scientific Laboratory; Mound Facility; Oak Ridge National Laboratory; Savannah River Laboratory; and UNC Nuclear Industries, Inc

  1. Radioisotopes and radiation technology

    International Nuclear Information System (INIS)

    Ramamoorthy, N.

    2011-01-01

    The field of radioisotopes and radiation processing has grown enormously all over the world with India being no exception. The chemistry and radiochemistry related inputs to the overall technology development and achievements have been, and will continue to be, of considerable value and importance in this multi-disciplinary and multi-specialty field. Harnessing further benefits as well as sustaining proven applications should be the goal in planning for the future. An objective analysis of the socio-economic impact and benefits from this field to the society at large will undoubtedly justify assigning continued high priority, and providing adequate resources and support, to relevant new projects and programmes on the anvil in the area of radioisotopes and radiation technology. It is necessary to nurture and strengthen inter-disciplinary and multi-specialty collaborations and cooperation - at both national and international level as a rule (not as exception) - for greater efficiency, cost-effectiveness and success of ongoing endeavors and future developments in this important field

  2. Radioisotope labelling of several major insect pest

    International Nuclear Information System (INIS)

    Sutrisno, Singgih

    1981-01-01

    Radioisotope uptake by insects could take place through various parts i.e. mouth, cuticula, intersegmental, secretion and excretion organs. Usually insects are labelled internally by feeding them on an artificial diet containing radioisotope solution. Labelling of several insect pests of cabbage (Crocidolomia binotalis) Zell and Plutella maculipennis Curt and rice (Chilo suppressalis Walker) by dipping of the pupae in 32 P solution showed a promising result. Pupae of Crocidolomia binotalis Zell dipped in 3 ml solution of 32 P with specific activities of 1, 3, 5 and 7 μCi/ml had developed labelled adults of sufficiently high radioactivity levels for ecological studies. Similar results were also obtained with Plutella maculipennis Curt and Chilo suppressalis Walker with doses of 1, 3, 5, 7 and 9 μCi/ml 32 P solution. The best doses for radioisotope labelling by dipping of the insects Crocidolomia binotalis Zell, Plutella maculipennis Curt, and Chilo suppressalis Walker were 1, 9, and 7 μCi/ml respectivelly. (author)

  3. Utilization of radioisotopes and irradiation in crop protection research

    International Nuclear Information System (INIS)

    Ong, S.H.

    1981-01-01

    There is a growing realization of the benefits which may be derived from the application of radioisotopes and radiation sources in the different disciplines of crop protection research. Many investigations which might only be carried out with extreme difficulty or not all by conventional methods, could be pursued with relative ease. Radioisotopes and irradiation have been utilized in understanding the physiology and behaviour of pests and their biochemical processes and in consequence, have contributed beneficially to the development of better control techniques and more effective pesticides. On the environmental aspects, radioisotopic techniques have provided a useful tool in understanding the behaviour, metabolism and residues of pesticides in the environment. (author)

  4. The use of radioisotope tracers in the metallurgical industries

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    Radioisotope techniques have been widely used in the metallurgical industries for many years. They have been shown to be very suitable for studying large scale plant and, in many cases, they are the most suitable techniques for such investigations. Applications of radioisotope tracers to some specific metallurgical problems are discussed. (author)

  5. Survey of industrial radioisotope savings

    International Nuclear Information System (INIS)

    1965-01-01

    Only three decades after the discovery of artificial radioactivity and two after radioisotopes became available in quantity, methods employing these as sources or tracers have found widespread use, not only in scientific research, but also in industrial process and product control. The sums spent by industry on these new techniques amount to millions of dollars a year. Realizing the overall attitude of industry to scientific progress - to accept only methods that pay relatively quickly - one can assume that the economic benefits must be of a still larger order of magnitude. In order to determine the extent to which radioisotopes are in daily use and to evaluate the economic benefits derived from such use, IAEA decided to make an 'International Survey on the Use of Radioisotopes in Industry'. In 1962, the Agency invited a number of its highly industrialized Member States to participate in this Survey. Similar surveys had been performed in various countries in the 1950's. However, the approaches and also the definition of the economic benefits differed greatly from one survey to another. Hence, the Agency's approach was to try to persuade all countries to conduct surveys at the same time, concerning the same categories of industries and using the same terms of costs, savings, etc. In total, 24 Member States of the Agency agreed to participate in the survey and in due course they submitted contributions. The national reports were discussed at a 'Study Group Meeting on Radioisotope Economics', convened in Vienna in March 1964. Based upon these discussions, the national reports have been edited and summarized. A publication showing the administration of the Survey and providing all details is now published by the Agency. From the publication it is evident that in general the return of technical information was quite high, of the order of 90%, but, unfortunately the economic response was much lower. However, most of the reports had some bearing on the economic aspects

  6. Survey of bone pain in patients of infectious section of Labafinejad hospital using radioisotope scanning

    International Nuclear Information System (INIS)

    Ibrahimie, Farhad

    1996-01-01

    Skeletal scintigraphy is the first or second most frequently performed imaging procedure in most nuclear medicine departments. The uses of bone scan in orthopedic practice are multiple. Bone scans are often used to localize disease, to identify areas of focal increased physiological activity, and to evaluate pain. Bone scans are particularly useful in depicting and localizing small tumors. Bone scans may clarify the significance of radiographic abnormalities. When pain is poorly localized, a bone scan helps focus attention, particularly when it precisely corresponds to the questionable radiographic lesion. In order to do a survey about role of bone scan for the detection and localizing bone pain, a retrospective study was done about 37 patient who from 1373 to 1374 were admitted to the infectious department of Martyr Labafinejad having bone pain. The results of our studies showed that most common case of bone pain of this patients was due to brucellosis (brucella arthritis) with 19%, and other causes were cellulits with 13.15% osteomyelitis and D.J.D with 11%, septic arthritis, bone metastasis, bone abscesses, discopathy, infectious spondylitis, lymphoma, D.V.T. and reactive traumatic arthritis with 2.7%

  7. List of ERDA radioisotope customers with summary of radioisotope shipments, FY-1974

    International Nuclear Information System (INIS)

    Simmons, J.L.; Mandell, S.

    1974-01-01

    The eleventh edition of the AEC radioisotope customer list has been prepared at the request of the Division of Biomedical and Environmental Research. The purpose of this document is to list the FY 1974 commercial radioisotope production and distribution activities of USAEC facilities at Argonne National Laboratory, Battelle, Pacific Northwest Laboratories, Brookhaven National Laboratory, United Nuclear Inc., Idaho Operations Office, Hanford Engineering Development Laboratory, Mound Laboratory, Oak Ridge National Laboratory, and Savannah River Plant. The information is divided into four sections. Section I is an alphabetical list of domestic and foreign customers and their addresses. Each customer has been designated a number according to its alphabetical position which provides a means of cross-referencing in the following sections. The isotopes purchased are listed after the address of the customer and the laboratory supplying each isotope is indicated by a letter set off by parentheses. Section II is an alphabetical list of isotopes, cross-referenced to customer numbers and again divided into the domestic and foreign categories. This section provides a quick idea of the amount of companies purchasing a particular isotope. If more information is needed, the reader can locate the customer by number and determine the laboratory supplying the isotope. The third section is an alphabetical list of states and countries, also cross-referenced to customer numbers, indicating geographical concentrations of isotope users. Section IV summarizes the FY 1974 radioisotope shipment activities of USAEC laboratories in a comprehensive table providing an alphabetical listing of the isotopes and their suppliers. The shipments, quantities and dollars are broken down for each isotope under the Domestic, Foreign, and Project (AEC facilities) categories, and the total figures for each isotope are also provided. (U.S.)

  8. Industrial applications of radioisotope techniques in Poland

    International Nuclear Information System (INIS)

    Michalik, J.St.

    1985-01-01

    A general review of applications of radioisotope techniques in the Polish industry for about 25 years is given. The radiotracer methods used in metallurgy, hydrometallurgy, glass industry, oil and petroleum industries, in material testing and in other industries are described. Neutron activation analysis methods as well as nuclear gauges for industry (thickness meters, density meters, conveyer belt weigher, acid concentration meters and others) are also presented. The economic advantages of industrial applications of radioisotope techniques are described too. 42 refs., 43 figs., 11 tabs. (author)

  9. Clinical evaluation of radioisotope examination in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Yasukochi, H [National Konodai Hospital (Japan)

    1979-07-01

    Although many approaches are tried for the diagnoses of malignant tumor, radiological examinations act surely main parts. Among the radiological examinations, radioisotope techniques are not well evaluated instead of their usefulness in this field. The reason may depend on the complexity and difficulty in legal limitations, however, the lack of knowledge in this field is also a main reason. In this paper, the present status of the evaluation of radioisotope techniques is discussed in selected region of the body and some characteristic cases are demonstrated.

  10. Development of radioisotope tracer technology and nucleonic control system

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee and others

    1999-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and basic technology of nuclear control systems that are widely used for automation of industrial plants, and to build a strong tracer group to support the local industries. In relation to the tracer technology, the data acquisition system, the column scanning equipment and the detection pig for a leakage test have been developed. In order to use in analyzing data of tracer experiments, a computer program for the analysis of residence time distribution has been created as well. These results were utilized in developing the tracer technologies, such as the column scanning, the flow measurement using the dilution method, the simultaneous monitoring rotational movement of piston rings and the optimization of a waste water treatment facility, and the technologies were successfully demonstrated in the local industrial. The stripper of RFCC reactor has been examined to find an unwanted structure in it by imminent request from the industry. Related to the development of nucleonic control system, the state of art report on the technology has been written and an equipment for the analysis of asphalt content has been developed. (author)

  11. Radioisotopes preparation with GA Siwabessy for application in health/medical

    International Nuclear Information System (INIS)

    Sunarhadijoso-Soenarjo

    2003-01-01

    The Center for Development of Radioisotopes and Radiopharmaceuticals (CDRR) has to improve its role and potency to comply domestic demand in radioisotope preparations. The radioisotopes are used as both primary radioisotopes and labeled compounds, especially for medical diagnosis and therapy as radiopharmaceutical preparations. The implementation of capability in production of radioisotopes and radiopharmaceuticals is fully affected by the readiness of operational function of supporting facilities in regard to maintain safety system, process and personnel as well. For those reasons, activities program has been carried out with the aims of : (a). To faithful capability in production of GA Siwabessy reactor based radioisotopes, labeled compounds and radiopharmaceutical kits, (b). To optimize normal operational function of supporting facilities and utilities, and (c). To perform invention and modification of heater and temperature control units on the air handling unit (AHU) system. Some kinds of radioactive products are dominant during the year of 2002, i.e. 153 SmCl 3 , Na 2 99 MoO 4 and Na 186 ReO 4 primary radioisotopes and 153 Sm-EDTMP labeled compound. The main utilization of the products is for research and development of processing technology and medical application as diagnostic or therapeutic agent. The operational function of supporting facilities and utilities was well performed meeting the requirement of the users. Some units of the systems partially showed degradation of working performance but it did not cause trouble in security and safety of the system, process and personnel. A heater device completed with control system has been installed as a modified part of AHU system and has been tested successfully. The operation of the heater device is significantly influential to the air temperature and humidity in working area. The required air condition, e.g. 22 - 25 o C of temperature and 40 - 50 % of humidity, can be complied on the blower motor

  12. Radioisotope production with a medical cyclotron

    International Nuclear Information System (INIS)

    Silvester, D.J.

    1974-01-01

    The cyclotron of Hammersmith hospital in England was completed and started the operation in 1955. The feature is in its design operable at high beam current, reaching 500μA in internal beam and 300μA in external beam. In 1960's, twelve nuclides of radioactive pharmaceuticals were produced with the cyclotron. C-11, N-13 and O-15 have been used in the form of radioactive gases such as CO or H 2 O to test lung functions. F-18 has been used for bone scanning. K-43 is employed in the research of electrolyte balancing together with Na-24 and Br-77. Fe-52 is utilized in iron ion researches as a tracer. Cs-129 is highly evaluated as an isotope for imaging cardiac clogging part. Radioisotopes must be much more used in the examination of in vivo metabolic function. For this purpose, peculiarly labelled compounds should be further developed. It is welcome that the persons paying attention to the medical prospect of cyclotrons are increasing. The author hopes to continue his endeavour to find new products made with the cyclotron for human welfare. (Wakatsuki, Y.)

  13. Radioisotopes in Burmese agricultural research

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-07-15

    The Burmese authorities decided to start a laboratory for the use of radioisotope techniques in agricultural r e search. The laboratory was set up at the Agricultural Research Institute at Gyogon, on the outskirts of Rangoon. Under its technical assistance program, IAEA assigned an expert in the agricultural applications of radioisotopes for this project. Discussions were held with regional representatives of the Food and Agriculture Organization on the best lines of research to be adopted at the laboratory in its early stages. As the most important crop in Burma is rice, a series of experiments were planned for a study of the nutrition of rice, particularly its phosphorus uptake, with special reference to comparative responses on a range of typical paddy soils. The experiments began last year and are being continued.

  14. Use of radioisotopes in Japan

    International Nuclear Information System (INIS)

    Foeldiak, G.

    1974-01-01

    A survey of the following general data on the use of radioisotopes in Japan is given (from the material of the 11th Japan Conference on Radioisotopes): 1. number of the organizations using radioactive isotopes, grouped according to special working fields and instruments; 2. amount of the unsealed sources (Ci) used in the different special working fields in 1971, 4. amount of the sealed sources (Ci) used between 1966 and 1971. 5. number of the institutions using sealed sources, grouped according to special working fields (March, 1972), 6. number of the accelerators applied, grouped according to special working fields (March, 1972), 7. number of the nuclear instruments in the education and research institutes (March, 1972), 8. amount of the collected radioactive waste material between 1960 and 1971 (number of containers). (K.A.)

  15. Distinction between amorphous and healed planar deformation features in shocked quartz using composite color scanning electron microscope cathodoluminescence (SEM-CL) imaging

    Science.gov (United States)

    Hamers, Maartje F.; Pennock, Gill M.; Herwegh, Marco; Drury, Martyn R.

    2016-10-01

    Planar deformation features (PDFs) in quartz are one of the most reliable and most widely used forms of evidence for hypervelocity impact. PDFs can be identified in scanning electron microscope cathodoluminescence (SEM-CL) images, but not all PDFs show the same CL behavior: there are nonluminescent and red luminescent PDFs. This study aims to explain the origin of the different CL emissions in PDFs. Focused ion beam (FIB) thin foils were prepared of specific sample locations selected in composite color SEM-CL images and were analyzed in a transmission electron microscope (TEM). The FIB preparation technique allowed a direct, often one-to-one correlation between the CL images and the defect structure observed in TEM. This correlation shows that composite color SEM-CL imaging allows distinction between amorphous PDFs on one hand and healed PDFs and basal Brazil twins on the other: nonluminescent PDFs are amorphous, while healed PDFs and basal Brazil twins are red luminescent, with a dominant emission peak at 650 nm. We suggest that the red luminescence is the result of preferential beam damage along dislocations, fluid inclusions, and twin boundaries. Furthermore, a high-pressure phase (possibly stishovite) in PDFs can be detected in color SEM-CL images by its blue luminescence.

  16. Development of radioisotope production in the Philippines

    Energy Technology Data Exchange (ETDEWEB)

    Cabalfin, E G [Philippine Nuclear Research Institute, Quezon (Philippines)

    1998-10-01

    The Philippine Nuclear Research Institute (PNRI) started its activities on radioisotope production more than three decades ago, when the Philippine Research Reactor (PRR-1) started operating at its full rated power of 1 MW. Since then, several radionuclides in different chemical forms, were routinely produced and supplied for use in nuclear medicine, industry, agriculture, research and training, until the conversion of the PRR-1 to a 3 MW TRIGA type reactor. After the criticality test of the upgraded reactor, a leak was discovered in the pool liner. With the repair of the reactor still ongoing, routine radioisotope production activities have been reduced to dispensing of imported bulk {sup 131}I. In the Philippines, radioisotopes are widely used in nuclear medicine, with {sup 131}I and {sup 99m}Tc as the major radionuclides of interest. Thus the present radioisotope production program of PNRI is directed to meet this demand. With the technical assistance of the International Atomic Energy Agency (IAEA), PNRI is setting up a new {sup 131}I production facility. The in-cell equipment have been installed and tested using both inactive and active target, obtained from BATAN, Indonesia. In order to meet the need of producing {sup 99}Mo-{sup 99m}Tc generators, based on low specific activity reactor-produced {sup 99}Mo, research and development work on the preparation of {sup 99m}Tc gel generators is ongoing. (author)

  17. Calculation correlations for radioisotope level gages with relay tracing systems

    International Nuclear Information System (INIS)

    Krejndlin, I.I.; Pakhunkov, Yu.I.

    1978-01-01

    The interrelationship was examined between the operational and instrumental parameters of radioisotope tracking level indicators. The relationships were obtained permitting to check the reliability of the tracking regime, and also of the equilibrium state of the radioisotope tracking level indicator

  18. Fluorescence of ceramic color standards

    International Nuclear Information System (INIS)

    Koo, Annette; Clare, John F.; Nield, Kathryn M.; Deadman, Andrew; Usadi, Eric

    2010-01-01

    Fluorescence has been found in color standards available for use in calibration and verification of color measuring instruments. The fluorescence is excited at wavelengths below about 600 nm and emitted above 700 nm, within the response range of silicon photodiodes, but at the edge of the response of most photomultipliers and outside the range commonly scanned in commercial colorimeters. The degree of fluorescence on two of a set of 12 glossy ceramic tiles is enough to introduce significant error when those tiles have been calibrated in one mode of measurement and are used in another. We report the nature of the fluorescence and the implications for color measurement.

  19. Determination of the radiological impact of radioisotope waste disposal

    International Nuclear Information System (INIS)

    1986-09-01

    The Atomic Energy Control Board (AECB) controls the uses of radioisotopes and the management of wastes resulting from radioisotope use through licences. In most cases, wastes generated through the use of radioisotopes are required by licence condition to be sent to Chalk River Nuclear Laboratories for storage but if the amounts of radioisotope are very small, have a low activity or a very short half-life, the radioisotope is permitted to be released to regular waste management systems. The AECB commissioned this study to determine the doses to individuals working in municipal waste management systems and to populations of cities where small amounts of radioisotopes are disposed of through the municipal waste managment systems. The Hamilton-Burlington area surrounding Hamilton Harbour was selected as the study area. The pathways and dosimetry models were put into a computer spread sheet, to give the model flexibility so that it could be easily modified to model other cities. Within the occupational critical group, the maximum doses were calculated for the Hamilton sewage treatment plant aeration worker at 1.2E-6 Sv/a. If this individual were also a member of the critical group in the general population, the maximum dose would be 2.0E-6 Sv/a. Individual doses to the critical group within the general population were calculated as 7.7E-7 Sv/a for adults and 6.8E-8 Sv/a for infants. These compare to AECB regulatory limits of 5.0E-2 Sv/a per person for atomic radiation workers and 5.0E-3 Sv/a per person for the general public. The collective population dose for the study area was 1.37E-1 person-Sv/a or an average dose of 2.6E-7 Sv/a per person for the 525,000 population

  20. Actual and future situations of the use of radioisotopes

    International Nuclear Information System (INIS)

    Paredes G, L.C.

    2005-01-01

    It is anticipated to medium term, an increase in the demand of the radioisotopes for medicine, industry and research, as well as the application of new radioisotopes derived from the development of new radiopharmaceuticals products for diagnosis and therapy applications. The personal and clinical dosimetry will have to be prepared for the new challenges. (Author)

  1. SIDA - System for importation distribution and acquisition of radioisotope - User manual

    International Nuclear Information System (INIS)

    1991-01-01

    The SIDA manual (system for importation, distribution and acquisition of radioisotopes) is presented. The SIDA is a system of consult and update to control importation and distribution of radioisotopes in the country. It allows to accompany processes from importation requirement to distribution of radioisotopes, executing the accountancy of I-125, which is distributed for several interprises. The system was developed in CLIPPER87 using DBASE III PLUS data base management. (M.C.K.)

  2. Radioisotope camera

    International Nuclear Information System (INIS)

    Tausch, L.M.; Kump, R.J.

    1978-01-01

    The electronic ciruit corrects distortions caused by the distance between the individual photomultiplier tubes of the multiple radioisotope camera on one hand and between the tube configuration and the scintillator plate on the other. For this purpose the transmission characteristics of the nonlinear circuits are altered as a function of the energy of the incident radiation. By this means the threshold values between lower and higher amplification are adjusted to the energy level of each scintillation. The correcting circuit may be used for any number of isotopes to be measured. (DG) [de

  3. Radioisotope Production Plan and Strategy of Kijang Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kye Hong; Lee, Jun Sig [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This reactor will be located at Kijang, Busan, Korea and be dedicated to produce mainly medical radioisotopes. Tc-99m is very important isotope for diagnosis and more than 80% of radiation diagnostic procedures in nuclear medicine depend on this isotope. There were, however, several times of insecure production of Mo-99 due to the shutdown of major production reactors worldwide. OECD/NEA is leading member countries to resolve the shortage of this isotope and trying to secure the international market of Mo-99. The radioisotope plan and strategy of Kijang Research Reactor (KJRR) should be carefully established to fit not only the domestic but also international demand on Mo-99. The implementation strategy of 6 principles of HLG-MR should be established that is appropriate to national environments. Ministry of Science, ICT and Future Planning and Ministry of Health and welfare should cooperate well to organize the national radioisotope supply structure, to set up the reasonable and competitive pricing of radioisotopes, and to cope with the international supply strategy.

  4. Radiation protection at radioisotope processing facilities

    International Nuclear Information System (INIS)

    Hillier, L.R.; Decaire, R.

    2002-01-01

    MDS Inc. is Canada's largest diversified health and life sciences company and provides health care services and products to prevent, diagnose and treat disease. MDS Nordion Inc. is a subsidiary of MDS Inc. and is located in Ottawa, Ontario. It provides much of the world's supply of radioisotopes used in nuclear medicine primarily to diagnose, but also to treat disease. MDS Nordion is composed of three major production divisions at its Ottawa location and serves customers in three major markets. These are primarily: radioisotopes used in nuclear medicine (Nuclear Medicine Division), radiation processing for sterilization of medical equipment and supplies, and food (Ion Technologies Division), and teletherapy equipment used in cancer treatment (Therapy Systems Division). MDS Nordion supplies customers in over 100 countries, exporting more than 95 percent of its product processed in Canada. Every year, 15 to 20 million diagnostic imaging tests are carried out in hospitals around the world, using radioisotopes supplied by MDS Nordion. In addition, 150 to 200 million cubic feet (that's enough to cover an entire CFL field - including the end zones - stacked over half a kilometer high) of single use medical products are sterilized using MDS Nordion supplied equipment. MDS Nordion receives medical isotopes from AECL, Chalk River Laboratories and processes the material to purify and quantify the radioisotope product. Sealed sources, comprised of cobalt 60, are supplied from CANDU reactors. Production processes include ventilated shielded cells with remote manipulators, gloveboxes and fumehoods, to effectively control the safety of the workplace and the environment, and to prevent contamination of the products. The facilities are highly regulated by the Canadian Nuclear Safety Commission (CNSC) for safety and environmental protection. Products are also regulated by Health Canada and the US-Food and Drug Administration (FDA). (author)

  5. Development of design of a radioisotope switchable neutron source and new portable detector of smuggling

    International Nuclear Information System (INIS)

    Meskhi, L.; Kurdadze, L.

    2010-01-01

    Development of simple and cheap radioisotope switchable neutron source for application in the portable device of detecting of smuggling is presented. Detailed calculations (Monte-Carlo modeling) for the purpose of optimization of a design of the source and the detector module are carried out. The sufficient an yield of neutrons, about 2 o 105 n/s provides the source with the sizes of approx 25 x 25 x 60 mm 3. Results of simulation of scanning smuggling areas (polyethylene 10 x 10 x 5 cm 3) behind the thick steel wall (1.2 cm) gave the relation of signal/ background 7-8

  6. Americium-241 radioisotope thermoelectric generator development for space applications

    International Nuclear Information System (INIS)

    Ambrosi, Richard; Williams, Hugo; Samara-Ratna, Piyal

    2013-01-01

    Space nuclear power systems are under development in the UK in collaboration with European partners as part of a European Space Agency (ESA) programme. Radioisotope thermoelectric generators (RTG) are an important element of this new capability in Europe. RTG systems being developed in Europe are targeting the 10 W electric to 50 W electric power generation range adopting a modular scalable approach to the design. Radiogenic decay heat from radioisotopes can be converted to electrical power by using appropriate semiconductor based thermoelectric materials. The plan for Europe is to develop radioisotope space nuclear power systems based on both thermoelectric and Stirling power conversion systems. Although primarily focused on delivering up to 50 W of electrical power, the European radioisotope thermoelectric system development programme is targeting americium-241 as a fuel source and is maximizing the use of commercially available thermoelectric manufacturing processes in order to accelerate the development of power conversion systems. The use of americium provides an economic solution at high isotopic purity and is product of a separation process from stored plutonium produced during the reprocessing of civil nuclear fuel. A laboratory prototype that uses electrical heating as a substitute for the radioisotope was developed to validate the designs. This prototype has now been tested. This paper outlines the requirements for a European americium-241 fuelled RTG, describes the most recent updates in system design and provides further insight into recent laboratory prototype test campaigns. (author)

  7. Americium-241 radioisotope thermoelectric generator development for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosi, Richard; Williams, Hugo; Samara-Ratna, Piyal, E-mail: rma8@le.ac.uk [University of Leicester, (United Kingdom); and others

    2013-07-01

    Space nuclear power systems are under development in the UK in collaboration with European partners as part of a European Space Agency (ESA) programme. Radioisotope thermoelectric generators (RTG) are an important element of this new capability in Europe. RTG systems being developed in Europe are targeting the 10 W electric to 50 W electric power generation range adopting a modular scalable approach to the design. Radiogenic decay heat from radioisotopes can be converted to electrical power by using appropriate semiconductor based thermoelectric materials. The plan for Europe is to develop radioisotope space nuclear power systems based on both thermoelectric and Stirling power conversion systems. Although primarily focused on delivering up to 50 W of electrical power, the European radioisotope thermoelectric system development programme is targeting americium-241 as a fuel source and is maximizing the use of commercially available thermoelectric manufacturing processes in order to accelerate the development of power conversion systems. The use of americium provides an economic solution at high isotopic purity and is product of a separation process from stored plutonium produced during the reprocessing of civil nuclear fuel. A laboratory prototype that uses electrical heating as a substitute for the radioisotope was developed to validate the designs. This prototype has now been tested. This paper outlines the requirements for a European americium-241 fuelled RTG, describes the most recent updates in system design and provides further insight into recent laboratory prototype test campaigns. (author)

  8. The radioisotopes and radiations program

    International Nuclear Information System (INIS)

    1982-01-01

    This program of the National Atomic Energy Commission of Argentina refers to the application and production of radionuclides, their compounds and sealed sources. The applications are carried out in the medical, agricultural, cattle raising and industrial areas and in other engineering branches. The sub-program corresponding to the production of radioactive materials includes the production of radioisotopes and of sealed sources, and an engineering service for radioactive materials production and handling facilities. The sub-program of applications is performed through several groups or laboratories in charge of the biological and technological applications, intensive radiation sources, radiation dosimetry and training of personnel or of potential users of radioactive material. Furthermore, several aspects about technology transfer, technical assistance, manpower training courses and scholarships are analyzed. Finally, some legal aspects about the use of radioisotopes and radiations in Argentina are pointed out. (M.E.L.) [es

  9. Control of the technological processes at ''Azovstal'' plant using radioisotope devices

    Energy Technology Data Exchange (ETDEWEB)

    Nosochenko, O V; Overchenko, Z V; Karpov, O I; Deryabina, G N

    1980-05-01

    Considered is the state of radioisotope control of the technological process at 'Azovstal' plant which has permitted to increase the quality of metal and of metal production. With the help of radioisotope densimeter PR-1024 carried out is the control of the density of the lime solution used for hearth spraying at pig iron casting. A system of automatic correction of skip coke supply according to indications of moisture gauges ''Neutron 3-1'' is implemented at blast furnaces. A radioisotope thickness gauge of hot rolling is positioned on the section of finishing stand of thick-sheet plant, its operation is based on the ..gamma.. radiation weakening in dependence on sheet thickness. The introduction of thickness gauges in the automatized system of rolling control is planned. A radioisotope device ''Paza 2'' for measuring of continuous ingot skin thickness is tested successively at the plant. Gamma-relay devices are used to control the level of loose materials in bunkers. Noted is the prospects of using radioisotopic means of control and automatization of technological processes in ferrous matallurgy.

  10. Status of NASA's Advanced Radioisotope Power Conversion Technology Research and Development

    Science.gov (United States)

    Wong, Wayne A.; Anderson, David J.; Tuttle, Karen L.; Tew, Roy C.

    2006-01-01

    NASA s Advanced Radioisotope Power Systems (RPS) development program is funding the advancement of next generation power conversion technologies that will enable future missions that have requirements that can not be met by either the ubiquitous photovoltaic systems or by current Radioisotope Power Systems (RPS). Requirements of advanced radioisotope power systems include high efficiency and high specific power (watts/kilogram) in order to meet mission requirements with less radioisotope fuel and lower mass. Other Advanced RPS development goals include long-life, reliability, and scalability so that these systems can meet requirements for a variety of future space applications including continual operation surface missions, outer-planetary missions, and solar probe. This paper provides an update on the Radioisotope Power Conversion Technology Project which awarded ten Phase I contracts for research and development of a variety of power conversion technologies consisting of Brayton, Stirling, thermoelectrics, and thermophotovoltaics. Three of the contracts continue during the current Phase II in the areas of thermoelectric and Stirling power conversion. The accomplishments to date of the contractors, project plans, and status will be summarized.

  11. Status and prospects on radioisotope production in Korea

    International Nuclear Information System (INIS)

    Han, H. S.; Cho, W. K.; Park, U. J.; Hong, Y. D.; Park, K. B.

    2002-01-01

    In Korea, radioisotopes has been produced using small-sized research reactors (TRIGA Mark II, III) from 1961 to 1995. The Korea Atomic Energy Research Institute (KAERI) completed the High-flux Advanced Neutron Application Reactor (HANARO) in 1995 and a radioisotope production facilities (RIPF) in 1997. Medical and industrial radionuclides such as 131 I, 99m Tc, 166 Ho, 192 Ir and 60 Co, are routinely produced utilizing HANARO. Several hundreds kilo curies of these nuclides were supplied to domestic users in 2001. The Korea Cancer Center Hospital (KCCH) first installed a cyclotron (MC-50) for neutron therapy and RI production in 1984. At present, the cyclotron routinely produced radionuclides such as 201 TI, 67 Ga, 123 I and 18 F. Also, it is capable of producing several radionuclides, including 111 In, 51 Cr, 124 I, 54 Mn, 22 Na, etc. Baby cyclotrons were installed in Seoul National University Hospital, Sam sung Medical Center and Asan Medical Center. The main purpose of the introduction of baby cyclotrons was to produce short-lived positron emitters such as 18 F, 15 O and 11 C for PET. Radioisotope production facilities were imported and installed as subsidiaries of cyclotron. In Korea, more than 60 kinds of radioisotopes are currently used in the field of their applications and most of them are imported form foreign vendors. For the quality assurance of final products such as radiopharmaceuticals and industrial sources, facilities for production should be installed and maintained in accordance with regulation rules and also the production system should be operated under quality management system. Since 1992 the Korean government has been encouraging Mid and Long Term Nuclear R and D Programs to enhance capability in nuclear technology development. In order to actively promote the utilization, research and development of technology applying radiation and RI, the Korean government established 'a comprehensive promotion plan for utilization, research and development

  12. Accurate color measurement methods for medical displays.

    Science.gov (United States)

    Saha, Anindita; Kelley, Edward F; Badano, Aldo

    2010-01-01

    The necessity for standard instrumentation and measurements of color that are repeatable and reproducible is the major motivation behind this work. Currently, different instrumentation and methods can yield very different results when measuring the same feature such as color uniformity or color difference. As color increasingly comes into play in medical imaging diagnostics, display color will have to be quantified in order to assess whether the display should be used for imaging purposes. The authors report on the characterization of three novel probes for measuring display color with minimal contamination from screen areas outside the measurement spot or from off-normal emissions. They compare three probe designs: A modified small-spot luminance probe and two conic probe designs based on black frusta. To compare the three color probe designs, spectral and luminance measurements were taken with specialized instrumentation to determine the luminance changes and color separation abilities of the probes. The probes were characterized with a scanning slit method, veiling glare, and a moving laser and LED arrangement. The scanning slit measurement was done using a black slit plate over a white line on an LCD monitor. The luminance was measured in 1 mm increments from the center of the slit to +/- 15 mm above and below the slit at different distances between the probe and the slit. The veiling glare setup consisted of measurements of the luminance of a black spot pattern with a white disk of radius of 100 mm as the black spot increases in 1 mm radius increments. The moving LED and laser method consisted of a red and green light orthogonal to the probe tip for the light to directly shine into the probe. The green light source was moved away from the red source in 1 cm increments to measure color stray-light contamination at different probe distances. The results of the color testing using the LED and laser methods suggest a better performance of one of the frusta probes

  13. Radioisotope production in the I. Ph. P. E. cyclotron for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Krasnov, N.N.; Dmitriyev, P.P.; Konjakhin, N.A.; Ognev, A.A. (Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Obninsk. Fiziko-Ehnergeticheskij Inst.)

    1982-01-01

    The production methods for seven radioisotopes, Ga-67, Sr-85, Pd-103, In-111, Tm-167, Hg-197 and Pb-203, by using a classical 1.5m cyclotron in the Institute of Physics and Power Engineering, Obninsk, USSR, are described. At present, more than 50 cyclotrons in different countries are used for the production of radioisotopes applied to medicine. Radioisotopes are produced with the cyclotron in the I.Ph.P.E. in the form of irradiated targets, which are delivered to Moscow radiopharmaceutical factory, where radiopharmaceuticals are produced on the base of these targets. The cyclotron is operated in two regimes providing the acceleration of protons, deuterons and alpha -particles. Two types of target assemblies are used for irradiation, the one is intended for the internal beam, and the other is for the external beam. The reactions used for the production of seven radioisotopes described above, the types of targets, particle energy, respective irradiated materials, beam current, thick target yield and the amount of respective radioisotopes produced per year are reported. Metals have large heat conductivity, therefore the use of metal targets increases beam current, and increases the production rate of radioisotopes.

  14. Radioisotope indicator, type BETA 2

    International Nuclear Information System (INIS)

    Duszanski, M.; Pankow, A.; Skwarczynski, B.

    1975-01-01

    The authors describe a radioisotope indicator, type BETA 2, constructed in the ZKMPW Works to be employed in mines for counting, checking, signalling the presence and positioning of cars, as well as monitoring the state of some other equipment. (author)

  15. Radioisotopes point the way ahead

    International Nuclear Information System (INIS)

    Evans, E.A.; Oldham, K.G.

    1988-01-01

    The use of radiochemicals as tracers in medicine is discussed, with particular reference to the choice of radioisotope to be used, its properties, quality control and its detection and measurement in tracer experiments. The development of autoradiography is discussed. (U.K.)

  16. Hair radioactivity as a measure of exposure to radioisotopes

    Science.gov (United States)

    Strain, W. H.; Pories, W. J.; Fratianne, R. B.; Flynn, A.

    1972-01-01

    Since many radioisotopes accumulate in hair, this tropism was investigated by comparing the radioactivity of shaved with plucked hair collected from rats at various time intervals up to 24 hrs after intravenous injection of the ecologically important radioisotopes, iodine-131, manganese-54, strontium-85, and zinc-65. The plucked hair includes the hair follicles where biochemical transformations are taking place. The data indicate a slight surge of each radioisotpe into the hair immediately after injection, a variation of content of each radionuclide in the hair, and a greater accumulation of radioactivity in plucked than in shaved hair. These results have application not only to hair as a measure of exposure to radioisotopes, but also to tissue damage and repair at the hair follicle.

  17. Charged particle cross-section database for medical radioisotope production: diagnostic radioisotopes and monitor reactions. Final report of a co-ordinated research project

    International Nuclear Information System (INIS)

    2001-05-01

    Medical applications of nuclear radiation are of considerable interest to the IAEA. Cyclotrons and accelerators, available in recent years in an increasing number of countries, are being used for the production of radioisotopes for both diagnostic and therapeutic purposes. The physical basis of this production is described through interaction of charged particles, such as protons, deuterons and alphas, with matter. These processes have to be well understood in order to produce radioisotopes in an efficient and clean manner. In addition to medical radioisotope production, reactions with low energy charged particles are of primary importance for two major applications. Techniques of ion beam analysis use many specific reactions to identify material properties, and in nuclear astrophysics there is interest in numerous reaction rates to understand nucleosynthesis in the Universe. A large number of medically oriented cyclotrons have been running in North America, western Europe and Japan for more than two decades. In recent years, 30-40 MeV cyclotrons and smaller cyclotrons (E p < 20 MeV) have been installed in several countries. Although the production methods are well established, there are no evaluated and recommended nuclear data sets available. The need for standardization was thus imminent. This was pointed out at three IAEA meetings. Based on the recommendations made at these meetings, the IAEA decided to undertake and organize the Co-ordinated Research Project (CRP) on Development of Reference Charged Particle Cross-Section Database for Medical Radioisotope Production. The project was initiated in 1995. It focused on radioisotopes for diagnostic purposes and on the related beam monitor reactions in order to meet current needs. It constituted the first major international effort dedicated to standardization of nuclear data for radioisotope production. It covered the following areas: Compilation of data on the most important reactions for monitoring light ion

  18. A facility to remotely assemble radioisotope thermoelectric generators

    International Nuclear Information System (INIS)

    Engstrom, J.W.; Goldmann, L.H.; Truitt, R.W.

    1992-07-01

    Radioisotope Thermoelectric Generators (RTGs) are electrical power sources that use heat from decaying radioisotopes to directly generate electrical power. The RTG assembly process is performed in an inert atmosphere inside a large glovebox, which is surrounded by radiation shielding to reduce exposure to neutron and gamma radiation from the radioisotope heat source. In the past, allowable dose rate limits have allowed direct, manual assembly methods; however, current dose rate limits require a thicker radiation shielding that makes direct, manual assembly infeasible. To minimize RTG assembly process modifications, telerobotic systems are being investigated to perform remote assembly tasks. Telerobotic systems duplicate human arm motion and incorporate force feedback sensitivity to handle objects and tools in a human-like manner. A telerobotic system with two arms and a three-dimensional (3-D) vision system can be used to perform remote RTG assembly tasks inside gloveboxes and cells using unmodified, normal hand tools

  19. Current utilization of research reactor on radioisotopes production in China

    International Nuclear Information System (INIS)

    Liu Yishu

    2000-01-01

    The main technical parameters of the four research reactors and their current utilization status in radioisotope manufacture and labeling compounds preparation are described. The radioisotopes, such as Co-60 sealed source, Ir-192 sealed source, γ-knife source, I-131, I-125, Sm-153, P-32 series products, In-113m generator, Tc-99m gel generator, Re-188 gel generator, C-14, Ba-131, Sr-89, 90 Y, etc., and their labeling compounds prepared from the reactor produced radionuclides, such as I-131-MIBG, I-131-Hippure, I-131-capsul, Sm-153-EDTMP, Re-186-HEDP, Re-186-HA, C-14-urea, and radioimmunoassay kits etc. are presented as well. Future development plan of radioisotopes and labeling compounds in China is also given. Simultaneously, the possibility and methods of bilateral or multilateral co-operation in utilization of research reactor, personnel and technology exchange of radioisotope production and labeling compounds is also discussed. (author)

  20. Current utilization of research reactor on radioisotopes production in China

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yishu [Nuclear Power Institute of China, Chengdu (China)

    2000-10-01

    The main technical parameters of the four research reactors and their current utilization status in radioisotope manufacture and labeling compounds preparation are described. The radioisotopes, such as Co-60 sealed source, Ir-192 sealed source, {gamma}-knife source, I-131, I-125, Sm-153, P-32 series products, In-113m generator, Tc-99m gel generator, Re-188 gel generator, C-14, Ba-131, Sr-89, {sup 90}Y, etc., and their labeling compounds prepared from the reactor produced radionuclides, such as I-131-MIBG, I-131-Hippure, I-131-capsul, Sm-153-EDTMP, Re-186-HEDP, Re-186-HA, C-14-urea, and radioimmunoassay kits etc. are presented as well. Future development plan of radioisotopes and labeling compounds in China is also given. Simultaneously, the possibility and methods of bilateral or multilateral co-operation in utilization of research reactor, personnel and technology exchange of radioisotope production and labeling compounds is also discussed. (author)

  1. Radioisotope programme in India: past, present and future

    International Nuclear Information System (INIS)

    Kohli, A.K.

    2012-01-01

    One of the major discoveries of the 20th century is the discovery of artificial radioactivity. This distinctive discovery in human history transformed atoms of one element to another. Until then, chemical reactions used to be concerned only with changes occurring outside the nucleus. The field of nuclear science came into existence with discovery of X-rays by Wilhelm Roentgen in 1895, radioactivity emitted by Uranium salt by Henri Becquerel in 1896 and pioneering work carried out by Madame Curie and Pierre Curie. India's atomic energy programme was envisaged, founded and developed by the great visionary Dr. Homi Jehangir Bhabha. Since then Department of Atomic Energy (DAE) of Government of India has been engaged in developing technologies for use of radiation in all possible fields for the benefit of society. The most common sources of radiation are radioisotopes. Radioisotopes are produced by nuclear reactors either by utilizing available excess neutrons for activation of stable elements or by separating useful fission products from the spent fuel. In India, the production of radioisotopes started with the commissioning of APSARA reactor in 1956. Initially, APSARA was operated at low power, and radioisotopes could be produced only on a small scale. All these operations had to be called out with remote handling or in the safe glove boxes keeping in view the radiation levels associated with the samples. In due course, the reactor reached full power and remotely operated processing equipment required for handling the radioisotopes were set up. Isotopes such as Iodine-131, Phosphorous-32, Gold-198 and Sodium-24 were produced and extracted in purified form in small quantities. These were given to KEM Hospital and Bombay Hospital at Mumbai, Vallabhbhai Patel Chest Institute and Safdarjung Hospital in Delhi, mainly for exploratory experiments

  2. Radioisotopic control and automation of food mills

    International Nuclear Information System (INIS)

    Pertsovskij, E.S.; Sakharov, Eh.V.; Dolinin, V.A.

    1980-01-01

    Domestic and foreign experience in application of radioisotope devices to process control in fool industry, is described. The diagrams of devices to block and account the production in systems of process monitoring and control are considered. The methods of determining chemical composition of substances are discussed, as sell as the devices used for those purposes and based on recording β-and γ-radiation absorption by substance. The methods for determining dust and smoke content in premises using radioisotope devices. Level indicators, moisture gages and densitimeters usedf ctol level humidity, density and concentration of food products in the process of production are described [ru

  3. Ordinance of the Prime Minister's Office concerning reports on transport of radioisotopes

    International Nuclear Information System (INIS)

    1981-01-01

    This rule is established under the provisions of the law on the prevention of radiation injuries by radioisotopes and the enforcement ordinance for this law, and to execute the law. Radioisotopes or the goods contaminated by radioisotopes which require reports are the same as those defined in the enforcement regulation for the law. Persons who intend to report on the transport of radioisotopes under the law shall submit two copies of reports in the form specified in this rule to the public safety commissions of prefectures which exercise jurisdiction over the dispatching places of these radioisotopes. The indication matters defined in this rule include speed of the vehicles loaded with radioisotopes, the disposition of escort cars, the formation of these vehicles, cars and other vehicles which accompany to transport, parking areas, the places of loading and unloading, etc. When the transport reported is related to the areas which are under the jurisdiction of other public safety commissions, those commissions which have received the reports shall inform without delay to the commissions concerned the date of transport, course, the kinds and quantities of radioisotopes and other necessary matters. The examinations of transport are made according to the contents of the reports submitted as to whether the transport was made as notified. Reports may be collected on the circumstances of transport outside works or enterprises and the personal injuries by the transport concerned, etc. (Okada, K.)

  4. Some activities of the IAEA on the use of radioisotopes and radiation

    International Nuclear Information System (INIS)

    Shalnov, A.V.

    1976-01-01

    The use of radioisotopes and radiation will continue to expand. There is an immediate and obvious use for radioisotopes in industry, medicine, agriculture and other branches of science. Working with isotopes and radiation is on the other hand an effective way of acquainting a large number of people with radiation and radioactivity, including radiation protection. One of the advantages of radioisotope technology is that it can be used in small laboratories such as those in universities, enhancing nuclear training. Owing to the extreme sensitivity and detectability of isotopes they are also advantageous in studies of the distribution of many materials, e.g. dust, air, water and soil. he programme of the IAEA in respect to the use of radioisotopes and radiation is concentrated mainly in the Department of Research and Isotopes. Some examples of IAEA activities in the application of radioisotopes will be mentioned in more detail, including isotope hydrology, physics, industrial applications, medicine and agriculture. (author)

  5. Stantardization problems in radioisotopic techniques for measuring rock density and humidity

    International Nuclear Information System (INIS)

    Golubin, O.V.; Pavlov, L.S.

    1977-01-01

    A description of the main technical characteristics is given of radioisotope densimeters and hydrometers taken as a base for the State Standard design for field radioisotope instruments for measuring density and moisture of the soil and rocks

  6. Development of radioisotope production in JAERI

    International Nuclear Information System (INIS)

    Yamabayashi, H.; Kato, H.; Umezawa, H.

    1992-01-01

    Since 1962, we have been developing methods and technology for producing a wide variety of processed radioisotopes and sealed radiation sources by using the JAERI's reactors, JRR-2, JRR-3, JRR-4 and JMTR, and providing the products to domestic users. At present, 29 nuclides and 31 products are on our list of processed radioisotopes. Some of those isotopes such as P-32, S-35, Cr-51 and short-lived nuclides are being produced regularly for distribution, but most of the rest are produced upon request. The radiation sources of Co-60 needles and Ir-192 pellets for industrial use and Gd-153 pellet, 7 kinds of Ir-192 and Au-198 grain for medical applications are produced and distributed routinely. (author)

  7. [Constructing 3-dimensional colorized digital dental model assisted by digital photography].

    Science.gov (United States)

    Ye, Hong-qiang; Liu, Yu-shu; Liu, Yun-song; Ning, Jing; Zhao, Yi-jiao; Zhou, Yong-sheng

    2016-02-18

    To explore a method of constructing universal 3-dimensional (3D) colorized digital dental model which can be displayed and edited in common 3D software (such as Geomagic series), in order to improve the visual effect of digital dental model in 3D software. The morphological data of teeth and gingivae were obtained by intra-oral scanning system (3Shape TRIOS), constructing 3D digital dental models. The 3D digital dental models were exported as STL files. Meanwhile, referring to the accredited photography guide of American Academy of Cosmetic Dentistry (AACD), five selected digital photographs of patients'teeth and gingivae were taken by digital single lens reflex camera (DSLR) with the same exposure parameters (except occlusal views) to capture the color data. In Geomagic Studio 2013, after STL file of 3D digital dental model being imported, digital photographs were projected on 3D digital dental model with corresponding position and angle. The junctions of different photos were carefully trimmed to get continuous and natural color transitions. Then the 3D colorized digital dental model was constructed, which was exported as OBJ file or WRP file which was a special file for software of Geomagic series. For the purpose of evaluating the visual effect of the 3D colorized digital model, a rating scale on color simulation effect in views of patients'evaluation was used. Sixteen patients were recruited and their scores on colored and non-colored digital dental models were recorded. The data were analyzed using McNemar-Bowker test in SPSS 20. Universal 3D colorized digital dental model with better color simulation was constructed based on intra-oral scanning and digital photography. For clinical application, the 3D colorized digital dental models, combined with 3D face images, were introduced into 3D smile design of aesthetic rehabilitation, which could improve the patients' cognition for the esthetic digital design and virtual prosthetic effect. Universal 3D colorized

  8. On clinical use of radioisotopes in the hospital and the commercial radioassay center

    International Nuclear Information System (INIS)

    Nukazawa, Atsushi

    1978-01-01

    The present status of the clinical use of radioisotopes in Tokyo district is reviewed. The increase from 1970 to 1974 in the quantity of radioisotopes used for radiotherapy is tabulated for each radioisotope. sup(99m)Tc has recorded remarkable increase. The in vitro use of 125 I has been also increasing. The number of 3 H kits used during 1974 was 573, which is 6.5 times as many as that in 1970. The increase in the number of organizations using radioisotopes, both in vitro and in vivo, is also presented in another table. The quantity (number of kits and curie) of each isotope used at various clinical organizations is tabulated for consecutive three years from 1974 to 1976. Other lists in this report provide the number of radioisotope suppliers and the examples if the registration format for the registered clinics. It is finally emphasized that urgent measures should be taken to establish the pertinent regulating laws for the treatment of radioisotopes in clinical organizations. (Aoki, K.)

  9. Investigation of process equipment in petrochemical industry using radioisotope technology

    International Nuclear Information System (INIS)

    Mohammed, M. S.

    2007-04-01

    Applications of radioisotope technology have proved it self to be an effective techniques for troubleshooting and optimizing industrial process in petrochemical industry. In this study, Khartoum refinery was investigated by gamma scanning technique for better understanding of malfunctions, the scanning were carried out using 60 C gamma radiation source with activity of 50 mCi on fractionator and stripper columns, obtained results showed that all trays of the fractionator column were in place but weeping was evident due to fouling or partial tray damage. For the stripper column, results obtained showed that all trays were on their positions and no process anomalies taking place. Heat exchanger was also examined using radiotracer technique with respect to leak detection and residence time distribution. The investigations were carried out using 82 Br in the form of di-bromo-para-bensene (C 6 H 4 Br 2 ) as a radiotracer. No leak was recorded and the residence time distribution results showed that the process functions were quite normal. Leak was examined using 99m Tc as a radiotracer detection to demonstrate the potentials of the technique. The testing was conducted using reflux condenser. Obtained results proved that the technique is sensitive, reliable and can be adopted to investigate heat exchangers in industrial systems.(Author)

  10. Use of radioisotopes in agriculture: DNA based molecular markers in crop improvement

    International Nuclear Information System (INIS)

    Sivaramakrishnan, S.; Seetharama, N.; Kannan, Seetha

    2001-01-01

    Agriculture has always benefited from the use of radioisotopes in many ways. In the beginning radioisotopes were mostly used for physiological studies to measure photosynthetic efficiency, nutrient uptake, and for mutation breeding. Radioisotopes have now become a part of the biotechnological tools that are being increasingly used in improving crops and production systems. The tools of biotechnology are being increasingly used to hasten breeding and address problems of biotic and abiotic stresses. Some of the non-radioactive methods have replaced radiotracer techniques and thus led to automation often at high cost. However, still there remain many applications where radioisotopes seem almost indispensable. For some of the applications like comparative genome mapping, the confirmation of transgenics, and establishment of gene copy number, use of RFLP with radioisotopes is essential. The following research areas at ICRISAT use radioisotopes: (1) physiological basis of adaptation to abiotic stresses (ii) development and use of appropriate DNA markers crop improvement; (iii) characterization of cytoplasmic male sterile systems and genetic diversity of breeding materials, land races and the wild relatives and (iv) molecular basis of disease resistance; (v) comparative genome mapping across cereals, (vi) isolation and characterization of genes of potential value to genetic improvement and (vii) verification of genetic transformation events. (author)

  11. Characterization of front-end electronics for CZT based handheld radioisotope identifier

    Energy Technology Data Exchange (ETDEWEB)

    Lombigit, L., E-mail: lojius@nm.gov.my [Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia); Rahman, Nur Aira Abd; Mohamad, Glam Hadzir Patai; Ibrahim, Maslina Mohd; Yussup, Nolida; Yazid, Khairiah; Jaafar, Zainudin

    2016-01-22

    A radioisotope identifier device based on large volume Co-planar grid CZT detector is current under development at Malaysian Nuclear Agency. This device is planned to be used for in-situ identification of radioisotopes based on their unique energies. This work reports on electronics testing performed on the front-end electronics (FEE) analog section comprising charge sensitive preamplifier-pulse shaping amplifier chain. This test involves measurement of charge sensitivity, pulse parameters and electronics noise. This report also present some preliminary results on the spectral measurement obtained from gamma emitting radioisotopes.

  12. Color standardization and optimization in Whole Slide Imaging

    Directory of Open Access Journals (Sweden)

    Yagi Yukako

    2011-03-01

    Full Text Available Abstract Introduction Standardization and validation of the color displayed by digital slides is an important aspect of digital pathology implementation. While the most common reason for color variation is the variance in the protocols and practices in the histology lab, the color displayed can also be affected by variation in capture parameters (for example, illumination and filters, image processing and display factors in the digital systems themselves. Method We have been developing techniques for color validation and optimization along two paths. The first was based on two standard slides that are scanned and displayed by the imaging system in question. In this approach, one slide is embedded with nine filters with colors selected especially for H&E stained slides (looking like tiny Macbeth color chart; the specific color of the nine filters were determined in our previous study and modified for whole slide imaging (WSI. The other slide is an H&E stained mouse embryo. Both of these slides were scanned and the displayed images were compared to a standard. The second approach was based on our previous multispectral imaging research. Discussion As a first step, the two slide method (above was used to identify inaccurate display of color and its cause, and to understand the importance of accurate color in digital pathology. We have also improved the multispectral-based algorithm for more consistent results in stain standardization. In near future, the results of the two slide and multispectral techniques can be combined and will be widely available. We have been conducting a series of researches and developing projects to improve image quality to establish Image Quality Standardization. This paper discusses one of most important aspects of image quality – color.

  13. Nuclear data for the production of radioisotopes in fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Cheng, E.T.; Schenter, R.E.; Mann, F.M.; Ikeda, Y.

    1991-01-01

    The fusion materials irradiation facility (FMIF) is a neutron source generator that will produce a high-intensity 14-MeV neutron field for testing candidate fusion materials under reactor irradiation conditions. The construction of such a facility is one of the very important development stages toward realization of fusion energy as a practical energy source for electricity production. As a result of the high-intensity neutron field, 10 MW/m 2 or more equivalent neutron wall loading, and the relatively high-energy (10- to 20-MeV) neutrons, the FMIF, as future fusion reactors, also bears the potential capability of producing a significant quantity of radioisotopes. A study is being conducted to identify the potential capability of the FMIF to produce radioisotopes for medical and industrial applications. Two types of radioisotopes are involved: one is already available; the second might not be readily available using conventional production methods. For those radioisotopes that are not readily available, the FMIF could develop significant benefits for future generations as a result of the availability of such radioisotopes for medical or industrial applications. The current production of radioisotopes could help finance the operation of the FMIF for irradiating the candidate fusion materials; thus this concept is attractive. In any case, nuclear data are needed for calculating the neutron flux and spectrum in the FMIF and the potential production rates of these isotopes. In this paper, the authors report the result of a preliminary investigation on the production of 99 Mo, the parent radioisotope for 99m Tc

  14. Current status of production and research of radioisotopes and radiopharmaceuticals in Indonesia

    International Nuclear Information System (INIS)

    Soenarjo, Sunarhadijoso; Tamat, Swasono R.

    2000-01-01

    The use of radioactive preparation in Indonesia has sharply increased during the past years, indicated by increase of the number of companies utilizing radioisotopes during 1985 to 1999. It has been clearly stressed in the BATAN's Strategic Plan for 1994-2014 that the production of radioisotopes and radiopharmaceuticals is one of five main industrial fields within the platform of the Indonesian nuclear industry. Research programs supporting the production of radioisotopes and radiopharmaceuticals as well as development of production technology are undertaken by the Research Center for Nuclear Techniques (RCNT) in Bandung and by the Radioisotope Production Center (RPC) in Serpong, involving cooperation with other research center within BATAN, universities and hospitals as well as overseas nuclear research institution. The presented paper describes production and research status of radioisotopes and radiopharmaceuticals in Indonesia after the establishment of P.T. Batan Teknologi in 1996, a government company assigned for activities related to the commercial application of nuclear technology. The reviewed status is divided into two short periods, i.e. before and after the Chairman Decree No. 73/KA/IV/1999 declaring new BATAN organizational structure. Subsequent to the Decree, all commercial requests for radioisotopes and radiopharmaceuticals are fulfilled by P.T. Batan Teknologi, while demands on novel radioactive preparations or new processing technology, as well as research and development activities should be fulfilled by the Center for the Development of Radioisotopes and Radiopharmaceuticals (CDRR) through non-commercial arrangement. The near-future strategic research programs to response to dynamic public demand are also discussed. The status of research cooperation with JAERI (Japan) is also reported. (author)

  15. U.S. Space Radioisotope Power Systems and Applications: Past, Present and Future

    Science.gov (United States)

    Cataldo, Robert L.; Bennett, Gary L.

    2011-01-01

    Radioisotope power systems (RPS) have been essential to the U.S. exploration of outer space. RPS have two primary uses: electrical power and thermal power. To provide electrical power, the RPS uses the heat produced by the natural decay of a radioisotope (e.g., plutonium-238 in U.S. RPS) to drive a converter (e.g., thermoelectric elements or Stirling linear alternator). As a thermal power source the heat is conducted to whatever component on the spacecraft needs to be kept warm; this heat can be produced by a radioisotope heater unit (RHU) or by using the excess heat of a radioisotope thermoelectric generator (RTG). As of 2010, the U.S. has launched 41 RTGs on 26 space systems. These space systems have ranged from navigational satellites to challenging outer planet missions such as Pioneer 10/11, Voyager 1/2, Galileo, Ulysses, Cassini and the New Horizons mission to Pluto. In the fall of 2011, NASA plans to launch the Mars Science Laboratory (MSL) that will employ the new Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) as the principal power source. Hundreds of radioisotope heater units (RHUs) have been launched to provide warmth to Apollo 11, used to provide heating of critical components in a seismic experiment package, Pioneer 10/11, Voyager 1/2, Galileo, Cassini, Mars Pathfinder, MER rovers, etc. to provide temperature control to critical spacecraft electronics and other mechanical devices such as propulsion system propellant valves. A radioisotope (electrical) power source or system (RPS) consists of three basic elements: (1) the radioisotope heat source that provides the thermal power, (2) the converter that transforms the thermal power into electrical power and (3) the heat rejection radiator. Figure 1 illustrates the basic features of an RPS. The idea of a radioisotope power source follows closely after the early investigations of radioactivity by researchers such as Henri Becquerel (1852-1908), Marie Curie (1867-1935), Pierre Curie (1859

  16. Analysis of status of radiation/radioisotopes utilization

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Lee, Seung Hyun; Kim, Na Kyung; Kim, Kon Wuk [Business Innovation Office, Korean Association for Radiation Application, Seoul (Korea, Republic of)

    2017-03-15

    The use of radiation and radioisotopes in Korea has been increasing each year, and its impact on economy and industry is expected to be increasing progressively following the development of industrial technology and the expansion of their usage. To establish and supporting policies for industries using radiation and radioisotopes, it is necessary to check the status of related industries accurately, as well as to gather data required to establish plans for industrial development by studying both revenues and economic scale (contributing to revenue). o analyze the status of utilization, surveys were carried out on 6,621 organizations engaged in nuclear operations handling radiation and radioisotopes pursuant to the Nuclear Safety Act as of end 2014, on 33,471 medical institutions using radiation generators for medical and diagnostic purposes pursuant to the Medical Service Act, and on 2,218 organizations using radiation generators for animal diagnostics pursuant to the Veterinary License Act. he overall status of the domestic radiation market including the number of user organizations, that of employees, and the size of distributions (imports, productions, and exports) with which the scale of domestic radiation market can be judged showed a growth trend compared to the previous year, though the number of employees for radiation operation in industrial sector, research sector, education sector, military sector, and power plants (nuclear power plants) and the size of imports was reduced somewhat. t is expected that data acquired through periodic surveys on the status of utilization would be utilized practically in establishing governmental policies related to the promotion of usage of radiation and radioisotopes, and also be utilized widely in cultivating and developing the industry efficiently to invigorate the related industries.

  17. Analysis of status of radiation/radioisotopes utilization

    International Nuclear Information System (INIS)

    Park, Chan Hee; Lee, Seung Hyun; Kim, Na Kyung; Kim, Kon Wuk

    2017-01-01

    The use of radiation and radioisotopes in Korea has been increasing each year, and its impact on economy and industry is expected to be increasing progressively following the development of industrial technology and the expansion of their usage. To establish and supporting policies for industries using radiation and radioisotopes, it is necessary to check the status of related industries accurately, as well as to gather data required to establish plans for industrial development by studying both revenues and economic scale (contributing to revenue). o analyze the status of utilization, surveys were carried out on 6,621 organizations engaged in nuclear operations handling radiation and radioisotopes pursuant to the Nuclear Safety Act as of end 2014, on 33,471 medical institutions using radiation generators for medical and diagnostic purposes pursuant to the Medical Service Act, and on 2,218 organizations using radiation generators for animal diagnostics pursuant to the Veterinary License Act. he overall status of the domestic radiation market including the number of user organizations, that of employees, and the size of distributions (imports, productions, and exports) with which the scale of domestic radiation market can be judged showed a growth trend compared to the previous year, though the number of employees for radiation operation in industrial sector, research sector, education sector, military sector, and power plants (nuclear power plants) and the size of imports was reduced somewhat. t is expected that data acquired through periodic surveys on the status of utilization would be utilized practically in establishing governmental policies related to the promotion of usage of radiation and radioisotopes, and also be utilized widely in cultivating and developing the industry efficiently to invigorate the related industries

  18. Radioisotope applications on fluidized catalytic cracking units

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1997-01-01

    Radioisotopes are used to trace the flow of all the phases of Fluidized Catalytic Cracking process in oil refineries. The gaseous phases, steam, hydrocarbon vapour and air, are generally traced using a noble-gas isotope, 41 Ar, 79 Kr or 85 Kr. An appropriate tracer for the catalyst is produced by irradiating a catalyst sample in a nuclear reactor. The activation products, 140 La and 24 Na provide appropriate radioactive 'labels' for the catalyst, which is reinjected into the FCC. An advantage of this approach is that it facilitates the study of the behaviour of different particle size fractions. Radioisotopes as sealed sources of gamma radiation are used to measure catalyst density variations and density distributions in critical parts of the unit. An important trend in radioisotope applications is the increasing use of the information they produce as inputs to or as validation of, mathematical process models. In line with the increasing sophistication of the models, the technology is undergoing continuous refinement. Developments include the investigation of more efficient, more convenient tracers, the introduction of systems to facilitate more rapid and comprehensive data acquisition and software refinements for enhanced data analysis

  19. Radioisotopes in engineering and industry

    International Nuclear Information System (INIS)

    Castagnet, A.C.G.

    1986-01-01

    The applications of radioisotope techniques in engineering and materials quality control are shown. The inventory of mercury in electrolytical cells, the transit and residence time measurements in several processes and radiotracer control are studied. The radioactive tracers in hydrologycal problems is evaluated. (M.J.C.) [pt

  20. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    International Nuclear Information System (INIS)

    Joh, Eunha; Park, Jang Guen

    2014-01-01

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future

  1. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Joh, Eunha; Park, Jang Guen [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future.

  2. Some results of radioisotope studies

    Energy Technology Data Exchange (ETDEWEB)

    Isamov, N.N.

    1974-10-01

    The accumulation of radioisotopes by brucellae depends on the consistency of the feed medium on which they are grown. The uptake of P-32 is a factor of 5 to 16 greater, and that of sulfur-35 in the form of sodium sulfate is a factor of 30 to 100 greater when grown on a complex solid agar than in a bouillion solution of the same ingredients. Brucellae are readily tagged with /sup 32/P and /sup 35/S simultaneously. These tagged brucellae were used to study in vitro storage under various temperature regimes. Brucellae actively incorporate iron. The uptake of methionine and cystine tagged with sulfur-35 by brucellae was investigated. Methionine is absorbed directly for the most part by brucellae, while the sulfur-35 in sodium sulfate is primarily transformed to cystine and cysteine. The uptake of various radioisotopes can be used to type various strains of brucellae. Isotopes are used to trace the course of various diseases in animals. (SJR)

  3. Safe Handling of Radioisotopes

    International Nuclear Information System (INIS)

    1958-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it has been considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. Such a manual is presented here and represents the first of a series of manuals and codes to be issued by the Agency. It has been prepared after careful consideration of existing national and international codes of radiation safety, by a group of international experts and in consultation with other international bodies. At the same time it is recommended that the manual be taken into account as a basic reference document by Member States of the Agency in the preparation of national health and safety documents covering the use of radioisotopes.

  4. Modern radioisotope production technologies for medicine

    International Nuclear Information System (INIS)

    Bechtold, V.; Schweickert, H.

    1989-01-01

    The advantages of the accelerator production of radioisotopes for medical purposes, are, above all, the high specific activity attainable as well as the possibility of the generation of nuclei with only a few neutrons which disintegrate due to β + emission or electron capture. It is, for example, possible to diagnostically utilize the developing long-range γ quanta by means of computerized tomography. The production of I-123 at the cyclotron of Karlsruhe (nuclear reaction, target, irradiation arrangement) as well as of ultra-pure I-123 with the help of compact cyclotrons, and the plant developed for this are described in brief. As another radioisotope which can be produced with the help of the compact cyclotron, Rb-81 is mentioned, the disintegration product Kr-81m of which is used in pulmonary diagnostics. (RB) [de

  5. Cosmogenic radioisotopes in Gebel Kamil meteorite

    Science.gov (United States)

    Taricco, C.; Colombetti, P.; Bhandari, N.; Sinha, N.; Di Martino, M.; Vivaldo, G.

    2012-04-01

    Recently a small (45 m in diameter) and very young (radioisotope activity generated by cosmic rays in the meteoroids as they travel through the interplanetary space before falling on the Earth. From the 26Al activity measurement and its depth production profiles, we infer (i) that the radius of the meteoroid should be about 1 m, constraining to 30-40 ton the range of pre-atmospheric mass previously proposed and (ii) that the fragment should have been located deeply inside the meteoroid, at a depth > 0.7 m. The 44Ti activity is under the detection threshold of the apparatus; using the depth production profiles of this radioisotope and its half-life T1/2 = 59.2 y, we deduce an upper limit to the date of fall.

  6. Medical radioisotope production - the Australian experience

    Energy Technology Data Exchange (ETDEWEB)

    Druce, M. [Australian Nuclear Science and Technology Organisation, Menai (Australia)

    1996-12-31

    The Australian government, through its instrumentality, the Australian Nuclear Science and Technology Organization (ANSTO), owns and operates a 10-MW Dido-class research reactor at Lucas Heights on the southern outskirts of Sydney. This is the only operating nuclear reactor in Australia. It was built in 1958 and has a maximum flux of 1 x 10{sup 14} n/cm{sup 2}{center_dot}s. ANSTO also jointly owns and operates a 30-MeV IBA negative ion cyclotron at Camperdown in central Sydney, which began operation in 1992. ANSTO is predominantly a research organization; however, radioisotopes are commercially produced through Australian Radioisotopes (ARI), an ANSTO business entity. Seventy-four people are employed by ARI, which is a vertically integrated organization, i.e., everything from target preparation to sale of products is undertaken.

  7. Radioisotope thermionic converters for space applications

    International Nuclear Information System (INIS)

    Miskolczy, G.; Lieb, D.P.

    1990-01-01

    The recent history of radioisotope thermionics is reviewed, with emphasis on the U.S. programs, and the prospects for the future are assessed. In radioisotope thermionic converters the emitter heat is generated by the decay of a radioactive isotope. The thermionic converter emitter is mounted directly on a capsule containing the isotope. The rest of the capsule is generally insulated to reduce thermal loss. The development of isotope-fueled thermionic power systems for space application has been pursued since the late 1950's. The U.S. effort was concentrated on modular systems with alpha emitters as the isotope heat source. In the SNAP-13 program, the heat sources were Cerium isotopes and each module produced about 100 watts. The converters were planar diodes and the capsule was insulated with multi-foil insulation

  8. Radioisotope 45Ca labeling four calcium chemical compounds and tracing calcium bioavailability

    International Nuclear Information System (INIS)

    Zheng Hui; Zhen Rong; Niu Huisheng; Li Huaifen

    2004-01-01

    Objective: To build up a new method of the radioisotope 45 Ca labeling four calcium chemical compounds, observe and tracing bioavailability change of calcium labeled with radioisotope 45 Ca. Methods: The calcium gluconate (Ca-Glu), calcium citrate (Ca-Cit), calcium carbonate (Ca-Car) and calcium L-threonate (Ca-Thr)were labeled by radioisotope 45 Ca. Four calcium chemical compounds of 45 Ca labeling were used of calcium content 200 mg/kg in the rats and measure the absorption content and bioavailability of calcium in tissue of heart, lever spleen, stomach, kidney, brain, intestine, whole blood, urine, faeces. Results: 1) Radioisotope 45 Ca labeling calcium chemical compound has high radio intensity, more steady standard curve and recover rate. 2) The absorption of organic calcium chemical compounds is higher than the inorganic calcium chemical compound in the study of calcium bioavailability. Conclusion: The method of tracing with radioisotope 45 Ca labeling calcium chemical compounds has the characteristic of the sensitive, objective, accurate and steady in the study of calcium bioavailability

  9. Facilities for the production and processing of radioisotopes

    International Nuclear Information System (INIS)

    Fourie, P.J.

    1980-01-01

    Radioisotopes which are used in South Africa are produced in the nuclear reactor SAFARI 1 of the AEB and the CSIR cyclotron in Pretoria or are being imported from various overseas manufactures. The safe and efficient production and use of radioisotopes is possible when being handled by sufficiently trained personnel using special designed equipment and facilities. The Isotope Production Centre is situated next to the reactor and waste treatment buildings. New production facilities shielded with lead and equipped with remote handling equipment are being erected and will be commissioned early during 1980 [af

  10. Solid targets for production of radioisotopes with cyclotron

    International Nuclear Information System (INIS)

    Paredes G, L.; Balcazar G, M.

    1999-01-01

    The design of targets for production of radioisotopes and radiopharmaceuticals of cyclotron to medical applications requires a detailed analysis of several variables such as: cyclotron operation conditions, choice of used materials as target and their physicochemical characteristics, activity calculation, the yielding of each radioisotope by irradiation, the competition of nuclear reactions in function of the projectiles energy and the collision processes amongst others. The objective of this work is to determine the equations for the calculation for yielding of solid targets at the end of the proton irradiation. (Author)

  11. Practical applications of short-lived radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-01-15

    The advantages of the use of short-lived radioisotopes in agriculture, food industry and medicine as well as some industrial uses are discussed. Methods for isotope production in small research reactors and laboratories are presented

  12. Present status and future trends of industrial radioisotopes application in Sudan

    International Nuclear Information System (INIS)

    Salih, A.S.

    2008-06-01

    Radioisotopes continue to play an important role in better management of natural resources, industrial growth and environmental preservation. The success of radioisotope applications is due primarily to the ability, conferred by the unique properties of radioactive materials, to collect data, where conventional methods fail or become uneconomical. These are prompt, on-line, in-situ and do not disturb the main industrial process in any way. In Sudan, the application of these nuclear techniques has considerable economic and environmental impact. This paper casts light on the present application of radioisotopes and future trends in the country.(Author)

  13. The brain, a choice subject for radioisotopic functional imaging

    International Nuclear Information System (INIS)

    Maziere, B.

    1996-01-01

    Progresses realized in the use of radioisotopes and in tomographic imaging techniques have permitted to access to the visualization of the human body functions. The application of this radioisotopic functional imaging (or emission tomography functional imaging) has been particularly fruitful in the study of brain functioning. This method is the only exploratory method for the biochemical aspects of the cerebral functioning and is used both by the physiologist and the therapist. (J.S.)

  14. Development of Kabila rocket: A radioisotope heated thermionic plasma rocket engine

    Directory of Open Access Journals (Sweden)

    Kalomba Mboyi

    2015-04-01

    Full Text Available A new type of plasma rocket engine, the Kabila rocket, using a radioisotope heated thermionic heating chamber instead of a conventional combustion chamber or catalyst bed is introduced and it achieves specific impulses similar to the ones of conventional solid and bipropellant rockets. Curium-244 is chosen as a radioisotope heat source and a thermal reductive layer is also used to obtain precise thermionic emissions. The self-sufficiency principle is applied by simultaneously heating up the emitting material with the radioisotope decay heat and by powering the different valves of the plasma rocket engine with the same radioisotope decay heat using a radioisotope thermoelectric generator. This rocket engine is then benchmarked against a 1 N hydrazine thruster configuration operated on one of the Pleiades-HR-1 constellation spacecraft. A maximal specific impulse and power saving of respectively 529 s and 32% are achieved with helium as propellant. Its advantages are its power saving capability, high specific impulses and simultaneous ease of storage and restart. It can however be extremely voluminous and potentially hazardous. The Kabila rocket is found to bring great benefits to the existing spacecraft and further research should optimize its geometric characteristics and investigate the physical principals of its operation.

  15. Current status of production and research of radioisotopes and radiopharmaceuticals in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Soenarjo, Sunarhadijoso; Tamat, Swasono R. [Center for Development of Radioisotopes and Radiopharmaceuticals, National Nuclear Energy Agency (BATAN), Kawasan Puspiptek, Serpong, Tangerang (Indonesia)

    2000-10-01

    The use of radioactive preparation in Indonesia has sharply increased during the past years, indicated by increase of the number of companies utilizing radioisotopes during 1985 to 1999. It has been clearly stressed in the BATAN's Strategic Plan for 1994-2014 that the production of radioisotopes and radiopharmaceuticals is one of five main industrial fields within the platform of the Indonesian nuclear industry. Research programs supporting the production of radioisotopes and radiopharmaceuticals as well as development of production technology are undertaken by the Research Center for Nuclear Techniques (RCNT) in Bandung and by the Radioisotope Production Center (RPC) in Serpong, involving cooperation with other research center within BATAN, universities and hospitals as well as overseas nuclear research institution. The presented paper describes production and research status of radioisotopes and radiopharmaceuticals in Indonesia after the establishment of P.T. Batan Teknologi in 1996, a government company assigned for activities related to the commercial application of nuclear technology. The reviewed status is divided into two short periods, i.e. before and after the Chairman Decree No. 73/KA/IV/1999 declaring new BATAN organizational structure. Subsequent to the Decree, all commercial requests for radioisotopes and radiopharmaceuticals are fulfilled by P.T. Batan Teknologi, while demands on novel radioactive preparations or new processing technology, as well as research and development activities should be fulfilled by the Center for the Development of Radioisotopes and Radiopharmaceuticals (CDRR) through non-commercial arrangement. The near-future strategic research programs to response to dynamic public demand are also discussed. The status of research cooperation with JAERI (Japan) is also reported. (author)

  16. Radioisotopic flow scanning for portal blood flow and portal hypertension

    International Nuclear Information System (INIS)

    Hesdorffer, C.S.; Bezwoda, W.R.; Danilewitz, M.D.; Esser, J.D.; Tobias, M.

    1987-01-01

    The use of a simple, noninvasive, isotope scanning technique for the determination of relative portal blood flow and detection of portal hypertension is described. Using this technique the presence of portal hypertension was demonstrated in seven of nine patients known to have elevated portal venous pressure. By contrast, esophageal varices were demonstrated in only five of these patients, illustrating the potential value of the method. Furthermore, this technique has been adapted to the study of portal blood flow in patients with myeloproliferative disorders with splenomegaly but without disturbances in hepatic architecture. Results demonstrate that the high relative splenic flow resulting from the presence of splenomegaly may in turn be associated with elevated relative portal blood flow and portal hypertension. The theoretic reasons for the development of flow-related portal hypertension and its relationship to splenic blood flow are discussed

  17. Failure analysis of radioisotopic heat source capsules tested under multi-axial conditions

    International Nuclear Information System (INIS)

    Zielinski, R.E.; Stacy, E.; Burgan, C.E.

    In order to qualify small radioisotopic heat sources for a 25-yr design life, multi-axial mechanical tests were performed on the structural components of the heat source. The results of these tests indicated that failure predominantly occurred in the middle of the weld ramp-down zone. Examination of the failure zone by standard metallographic techniques failed to indicate the true cause of failure. A modified technique utilizing chemical etching, scanning electron microscopy, and energy dispersive x-ray analysis was employed and dramatically indicated the true cause of failure, impurity concentration in the ramp-down zone. As a result of the initial investigation, weld parameters for the heat sources were altered. Example welds made with a pulse arc technique did not have this impurity buildup in the ramp-down zone

  18. Scanning with a Total Information Storage and Controlled Data Presentation System

    Energy Technology Data Exchange (ETDEWEB)

    Rejali, A. M.; Gregg, E. C.; Voelker, W. H.; Friedell, H. L. [Case Western Reserve University, Cleveland, OH (United States)

    1969-01-15

    This presentation demonstrates improved clinical results obtained from storing all available information received by the detector or detectors without prior modifications in a permanent memory. Permanently stored information is modified later with a special electronic imaging system with kinescope presentation in black and white or colour. Under carefully controlled circumstances this system permits immediate and innumerable degrees of erase and contrast enhancement or colour coding in fractions of a second. A profile representing the count-rate through any slice in the scanned area may be performed to determine relative distribution of radioisotopes. The advantage of this system and various clinical results in scans of myocardiums, pancreas, cardiac blood pool, placenta, etc. will be presented. (author)

  19. The regulations for enforcing the law concerning prevention from radiation hazards due to radioisotopes

    International Nuclear Information System (INIS)

    1978-01-01

    These provisions are established on the basis of and to enforce the ''Law for the prevention of radiation hazards due to radioisotopes'' and the Enforcement Order for the ''Law concerning the prevention of radiation hazards due to radioisotopes''. The Regulation includes the definitions of terms, applications for the permission of the use of radioisotopes, standards on usage, obligation of measurement, persons in charge of radiation, etc. Terms are explained, such as persons engaging in radiation works, persons who enter at any time the control areas, radiation facilities, maximum permissible exposure dose, cumulative dose, maximum permissible cumulative dose, maximum permissible concentration in the air, maximum permissible concentration in water and maximum permissible surface density. The applications for permission in written forms are required for the use, sale and abandonment of radioisotopes. Radioisotopes or the apparatuses for generating radiation shall be used in the using facilities. The measurement of radiation dose rate, particle flux density and contamination due to radioisotopes shall be made with radiation-measuring instruments. At least one person shall be chosen as the chief radiation-handling person in each factory, establishment, selling office or abandoning establishment by a user, a trademan or a person engaged in abandonment of radioisotopes. The forms for the application for permission, etc. are attached. (Okada, K.)

  20. Tracer experiment by using radioisotope in surface water environment

    International Nuclear Information System (INIS)

    Suh, K.S.; Kim, K.C.; Chun, I.Y.; Jung, S.H.; Lee, C.W.

    2007-01-01

    Complete text of publication follows. 1. Objective An expansion of industrial activities and urbanization result in still increasing amount of pollutants discharged into surface water. Discharged pollutants in surface water have harmful effects on the ecology of a river system and human beings. Pollutants discharged into surface water is transported and dispersed under conditions characteristic to particular natural water receiver. Radiotracer method is a useful tool for monitoring the pollutant dispersion and description of mixing process taking place in natural streams. A tracer experiment using radioisotope was carried out to investigate the characteristics of a pollutant transport and a determination of the diffusion coefficients in a river system. 2. Methods The upper area of the Keum river was selected for the tracer experiment, which is located in a mid west of Korea. The measurements of the velocity and bathymetry before a tracer experiment were performed to select the sampling lines for a detection of the radioisotope. The radioisotope was instantaneously injected into a flow as a point source by an underwater glass-vial crusher. The detection was made with 60 2inch NaI(Tl) scintillation detectors at 3 transverse lines at a downstream position. The multi-channel data acquisition systems were used to collect and process the signals transmitted from the detectors. Two-dimensional numerical models were used to simulate the hydraulic parameters and the concentration distributions of the radioisotope injected into the river. 3. Results and Conclusion The calculated results such as velocity and concentrations were compared with the measured ones. The dispersion characteristics of the radioisotope were analyzed according to a variation of the flow rate, water level and diffusion coefficients. Also, the diffusion coefficients were calculated by using the measured concentrations and the coefficients obtained from the field experiment were compared with the ones

  1. Steps of radioisotope separation in Japan

    International Nuclear Information System (INIS)

    Nakane, Ryohei; Kitamoto, Asashi; Shimizu, Masami

    1998-03-01

    The Extraordinary Specialist Committee on Radioisotope Separation of the Atomic Energy Society of Japan has supported various actions on foundation, application and industrialization of the radioisotope separation over past 30 years to continue wide range of actions at a standpoint of specialist, since established in Showa 44 (1969). On June 1993 (Heisei 5), a memorial lecture meeting, as the 100th committee was held at the Institute of Physical and Chemical Research (RIKEN) of Wako-city in Saitama prefecture. At that time, a planning to publish an impressive memorial issue, to prepare orbits and episodes of actions, painful stories and fault examples of developments, and so forth like novels and to use for a future foundation, was determined. For its writing principle, it was settled to the base not to use mathematical equation as possible, to collect the essence like a tale, to collect actual and historical reports, and so on. And, for its writing content, it was determined to report on actual, painful and fault experiences in research and development, on data, topics and human relation, and on what to be remained for references. This book can be used not only for data collected on traces from fundamental to applied studies, technical development for industrialization, and so forth on radioisotope concentration, but also for a knowledge bag to give some hints to a man aiming to overcome a new problem. (G.K.)

  2. Production capabilities in US nuclear reactors for medical radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mirzadeh, S.; Callahan, A.P.; Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Schenter, R.E. (Westinghouse Hanford Co., Richland, WA (United States))

    1992-11-01

    The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at the Brookhaven National Laboratory (BNL) High Flux Beam Reactor (HFBR). In March 1988, however, the HFBR was temporarily shut down which forced investigators to look at other reactors for production of the radioisotopes. During this period the Missouri University Research Reactor (MURR) played an important role in providing these services. The HFIR resumed routine operation in July 1990 at 85 MW power, and the HFBR resumed operation in June 1991, at 30 MW power. At the time of the HFBR shutdown, there was no available comprehensive overview which could provide information on status of the reactors operating in the US and their capabilities for radioisotope production. The obvious need for a useful overview was thus the impetus for preparing this survey, which would provide an up-to-date summary of those reactors available in the US at both the DOE-funded national laboratories and at US universities where service irradiations are currently or expected to be conducted.

  3. Production capabilities in US nuclear reactors for medical radioisotopes

    International Nuclear Information System (INIS)

    Mirzadeh, S.; Callahan, A.P.; Knapp, F.F. Jr.; Schenter, R.E.

    1992-11-01

    The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at the Brookhaven National Laboratory (BNL) High Flux Beam Reactor (HFBR). In March 1988, however, the HFBR was temporarily shut down which forced investigators to look at other reactors for production of the radioisotopes. During this period the Missouri University Research Reactor (MURR) played an important role in providing these services. The HFIR resumed routine operation in July 1990 at 85 MW power, and the HFBR resumed operation in June 1991, at 30 MW power. At the time of the HFBR shutdown, there was no available comprehensive overview which could provide information on status of the reactors operating in the US and their capabilities for radioisotope production. The obvious need for a useful overview was thus the impetus for preparing this survey, which would provide an up-to-date summary of those reactors available in the US at both the DOE-funded national laboratories and at US universities where service irradiations are currently or expected to be conducted

  4. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  5. Procedures for determining stream flowrate using radioisotope method in Pesanggrahan River, Indonesia. Prosedur untuk mengukur kadar-alir sungai menggunakan kaedah radioisotop di Sungai Pesanggrahan, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    1983-08-01

    River flow measurements either by a current meter or a tracer dilution are established elsewhere. This report describes the experimental method, calibrations of NaI detector, preparation of radioisotopes and equipment, and safety aspect considerations as well as results interpretation in determining stream flowrate of Pesanggrahan River, Indonesia in which radioisotopes /sup 82/Br and /sup 51/Cr complexed with EDTA were used as tracers. The total count technique of stream flow D=AF/N, developed by Hull, was simplified for the ease of field work purposes and adopted in this study. Discharge results at different water levels during low flows gauged using both radioisotope tracers are comparable. The relationship between water level and discharge value is also plotted although the available data is insufficient.

  6. Present status of radioisotope production in JAERI

    International Nuclear Information System (INIS)

    Yamabayashi, Hisamichi

    1994-01-01

    Since 1962, the technology for producing a wide variety of processed radioisotopes and sealed radiation sources has been developed by using the reactors, JRR-1, JRR-2, JRR-3, JRR-4 and JMTR, and the products have been offered to domestic users. At present, 31 products of 29 nuclides are on the list of processed radioisotopes. Some of those isotopes such as P-32, S-35, Cr-51 and short lived nuclides are produced for regular distribution, but the rest are produced upon request. The radiation sources of Co-60 needles for industrial use, Ir-192 pellets for the nondestructive inspection of pipelines, Gd-153 pellets for the diagnosis of born mineral and seven kinds of brachy therapy Ir-192 and Au-198 grains are produced and distributed regularly. The organic compounds labeled with H-3 and C-14 are widely used. In fiscal year 1992, 34 batches and total amount 12 TBq of processed radioisotopes and 100 batches, 1.2 PBq of radiation sources were produced as scheduled. The development of the techniques for producing the sources emitting high energy β ray used for the diagnosis and treatment of cancer is in progress. The method of producing new isotopes is developed. (K.I.)

  7. Clustering of color map pixels: an interactive approach

    Science.gov (United States)

    Moon, Yiu Sang; Luk, Franklin T.; Yuen, K. N.; Yeung, Hoi Wo

    2003-12-01

    The demand for digital maps continues to arise as mobile electronic devices become more popular nowadays. Instead of creating the entire map from void, we may convert a scanned paper map into a digital one. Color clustering is the very first step of the conversion process. Currently, most of the existing clustering algorithms are fully automatic. They are fast and efficient but may not work well in map conversion because of the numerous ambiguous issues associated with printed maps. Here we introduce two interactive approaches for color clustering on the map: color clustering with pre-calculated index colors (PCIC) and color clustering with pre-calculated color ranges (PCCR). We also introduce a memory model that could enhance and integrate different image processing techniques for fine-tuning the clustering results. Problems and examples of the algorithms are discussed in the paper.

  8. Radioisotope Power System Delivery, Ground Support and Nuclear Safety Implementation: Use of the Multi-Mission Radioisotope Thermoelectric Generator for the NASA's Mars Science Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    S.G. Johnson; K.L. Lively; C.C. Dwight

    2014-07-01

    Radioisotope power systems have been used for over 50 years to enable missions in remote or hostile environments. They are a convenient means of supplying a few milliwatts up to a few hundred watts of useable, long-term electrical power. With regard to use of a radioisotope power system, the transportation, ground support and implementation of nuclear safety protocols in the field is a complex process that requires clear identification of needed technical and regulatory requirements. The appropriate care must be taken to provide high quality treatment of the item to be moved so it arrives in a condition to fulfill its missions in space. Similarly it must be transported and managed in a manner compliant with requirements for shipment and handling of special nuclear material. This presentation describes transportation, ground support operations and implementation of nuclear safety and security protocols for a radioisotope power system using recent experience involving the Multi-Mission Radioisotope Thermoelectric Generator for National Aeronautics and Space Administration’s Mars Science Laboratory, which launched in November of 2011.

  9. Spallation production of neutron deficient radioisotopes in North America

    International Nuclear Information System (INIS)

    Jamriska, D.J.; Peterson, E.J.; Carty, J.

    1997-01-01

    The United States Department of Energy produces a number of neutron deficient radioisotopes by high energy proton induced spallation reactions in accelerators at Los Alamos National Laboratory in New Mexico and Brookhaven National Laboratory in New York. Research isotopes are also recovered from targets irradiated at TRIUMF in British Columbia, Canada. The radioisotopes recovered are distributed for use in nuclear medicine, environmental research, physics research, and industry worldwide. In addition to the main product line of Sr-82 from either Mo or Rb targets, Cu-67 from ZnO targets, and Ge-68 from RbBr targets, these irradiation facilities also produce some unique isotopes in quantities not available from any other source such as Be-10, Al-26, Mg-28, Si-32, El-44, Fe-52, Gd-248, and Hg-194. We will describe the accelerator irradiation facilities at the Los Alamos and Brookhaven National Laboratories. The high level radiochemical processing facilities at Los Alamos and brief chemical processes from Los Alamos and Brookhaven will be described. Chemical separation techniques have been developed to recover the radioisotopes of interest in both high radiochemical purity and yield and at the same time trying to reduce or eliminate the generation of mixed waste. nearly 75 neutron deficient radioisotopes produced in spallation targets have been produced and distributed to researchers around the world since the inception of the program in 1974

  10. The application of radioisotopes in the Argentine technology

    International Nuclear Information System (INIS)

    Baro, G.B.; Lazor, C.J.

    1976-10-01

    The different applications of radioisotopes: as sealed sources or tracers, as well as activation analysis have cast a new light on Argentine engineering and industry. The Argentine Atomic Energy Commission is carrying out an active plan for the developement and promotion of these techniques since the 60's. This report describes and analyzes the most outstanding applications, and brings up to date other previous papers on the same subject. It suggests some ideas for achieving a complete penetration of radioisotope techniques into Argentine technology. It also outlines some future perspectives, based on present statistical data. (author) [es

  11. Radiation risk assessment for the transport of radioisotopes using KRI-BGM B(U) type container

    International Nuclear Information System (INIS)

    Cho, Woon-Kap

    2008-01-01

    The radiation risks were estimated for the transportation of radioisotopes using KRI-BGM transport container. KRI-BGM container was specially designed for transportation of large amount of radioisotopes for industrial or medical applications. The container can carry maximum 370 TBq of solid Ir-192, 29.6 TBq of liquid Mo-99 and 37 TBq of liquid I-131 respectively. For the radiation risk assessment, it was assumed that maximum design activity of those radioisotopes was transported. Transportation route is from Daejeon where radioisotopes are produced to Seoul where radioisotopes are consumed. Transport distance is 200 km including highway and downtown area from Daejeon to Seoul. As the transportation conveyance, an ordinary cargo truck is used exclusively. Radiation risks were estimated for incident free and accident condition of transportation and RADTRAN 5.6 was used as the risk assessment tool. For the risk assessment of radioisotopes transportation, various parameters such as population density around transport route, weather condition, probability of specific accidents such as impact, fire, etc. were considered. From the results of this study, the exclusive transportation of radioisotopes using KRI-BGM transport container by truck showed low radiological risks with manageable safety and health consequences. This paper discusses the methods and results of the radiation risks assessment for the radioisotopes transportation by an ordinary truck and presents the expected radiation risks in person-Sv and latent cancer fatalities. (author)

  12. Determination of details of regulations concerning transportation of radioisotopes by vehicles

    International Nuclear Information System (INIS)

    1979-01-01

    The determination is defined under the regulation concerning transportation of radioactive materials by vehicles. Permissible surface density shall be 1/100,000 micro-curie per centi-meter 2 for radioisotopes emitting alpha rays and 1/10,000 micro-curie per centi-meter 2 for radioisotopes not emitting alpha rays. Radioisotope loads are classified to types of L, A, BM and BU. Quantity of radioactivity or radioisotope is stipulated for each type of loads respectively with tables attached. Radioactivity quantity of solid L load is 1/1,000 of Al value in the appendix table. For tritium water of fluid L load radioactivity quantity is 1,000 curie, 100 curie and 1 curie respectively according to the water radioactivity per litre of less than 0.1 curie, less than 1 curie and more than 0.1 curie, and more than 1 curie. Conditions concerning A, BM and BU loads are provided for in detail in the bylaw annexed. Quantity of leaking specified for BM load is 1/1,000,000 of A2 value and in other particular cases A2 value, etc. Leaking quantity for BU load is 1/1,000 of A2 value. Radioactive concentration of radioisotopes to be transferred not as radioactive goods is 1/10,000 of A2 value per gram. (Okada, K.)

  13. Efficient thermo-mechanical generation of electricity from the heat of radioisotopes

    International Nuclear Information System (INIS)

    Cooke-Yarborough, E.H.; Yeats, F.W.

    1975-01-01

    The thermomechanical generator uses a thermomechanical oscillator to convert heat efficiently into a mechanical oscillation which in turn excites a suitable transducer to generate alternating electricity. The thermomechanical oscillator used is based on the Stirling cycle, but avoids the need for rotary motion and for sliding pistons by having a mechanically-resonant, spring-suspended displacer, and by using an oscillating metal diaphragm to provide the mechanical output. The diaphragm drives an alternator consisting of a spring-suspended permanent magnet oscillating between fixed pole pieces which carry the electrical power output windings. Because a thermomechanical generator is much more efficient than a thermo-electric generator at comparable temperatures, it is particularly suitable for use with a radioisotope heat source. The amounts of radioisotope and of shielding required are both greatly reduced. A machine heated by radioisotopes and delivering 10.7W ac at 80Hz began operating in October, 1974. Operating experience with this machine is reported, and these results, together with those obtained with higher-powered machines heated by other means, are used to calculate characteristics and performance of thermo-mechanical radioisotope generators capable of using heat sources such as the waste-management 90 Sr radioisotope sources becoming available from the US nuclear waste management programme. A design to use one of these heat sources in a 52-W underwater generator is described

  14. Liver scanning using indium-113m at the University Teaching Hospital, Lusaka, Zambia

    Energy Technology Data Exchange (ETDEWEB)

    Mulaisho, C [Nuclear Medicine Unit, Department of Medicine, University of Zambia, Lusaka, Zambia; Mumba, K N [Radio-isotope Research Unit, National Council for Scientific Research, Lusaka, Zambia

    1981-11-21

    Liver scanning using the radio-isotope indium-113m, can now be routinely perfomed at the University Teaching Hospital, Lusaka, Zambia. The dose used is 1 - 4 mCi. Liver scans have been performed on 48 subjects, including 10 healthy individuals 16 patients with histologically proven hepatocellular carcinoma, 11 with clinical and laboratory evidence of portal hypertension and 11 with miscellaneous illnesses. Seven representative scans are illustrated. The procedure is easy, and gives a fairly accurate functional estimate of Kupffer cell mass. In hepatoma the scan may be either larger than or smaller than normal and reflects more accurately the residual function of the Kupffer cells. In cirrhosis of the liver with portal hypertention, residual Kupffer cell mass is small. Consequently, most of the indium-113m is taken up by the splenic reticulo-endothelial system, resulting in a large spleen scan. This technique, although fraught with major limitations, is a useful additional diagnostic tool in the management of chronic liver disease.

  15. Radioisotope production at the cyclotron in Rio de Janeiro, Brazil

    International Nuclear Information System (INIS)

    Silva, A.G. da; Lemos, O.F.; Britto, J.L.O. de; Osso, J.A.; Bastos, M.A.V.; Braghirolli, A.M.S.; Chamma, D.F.S.; Newton, G.W.A.; Weinreich, R.

    1982-01-01

    A radioisotope production laboratory has been installed at Instituto de Engenharia Nuclear in Rio de Janeiro. It is intended primarily for processing short-lived radioisotopes produced by a multiparticle, variable energy, isochronous, compact CV-28 Cyclotron and for preparation of radiopharmaceuticals and labelled molecules. Carrier-free iodine-123, indium-111, thalium-201, bromine-77 and gallium-67 with high purity have been produced. An irradiated target transport system has been built. Special targets that can dissipate high surface power densities are being developed. Each radioisotope is processed in a remotely controlled cell equiped with electric and pneumatic systems as well as manipulators ans tongs. Quality control is achieved by atomic absorption spectrophotometry, spot tests, gamma-ray spectroscopy and thin-layer chromatography. Biological tests in mice have confirmed the good quality of the radiopharmaceuticals. (Author) [pt

  16. Development of Radioisotope Tracer Technology

    International Nuclear Information System (INIS)

    Jung, Sung Hee; Jin, Joon Ha; Kim, Jong Bum; Kim, Jin Seop; Kim, Jae Jo; Park, Soon Chul; Lim, Don Soon; Choi, Byung Jong; Jang, Dong Soon; Kim, Hye Sook

    2007-06-01

    The project is aimed to develop the radiotracer technology for process optimization and trouble-shooting to establish the environmental and industrial application of radiation and radioisotopes. The advanced equipment and software such as high speed data acquisition system, RTD model and high pressure injection tool have developed. Based on the various field application to the refinery/petrochemical industries, the developed technology was transfer to NDT company for commercial service. For the environmental application of radiotracer technology, injector, detector sled, core sampler, RI and GPS data logging system are developed and field tests were implemented successfully at Wolsung and Haeundae beach. Additionally tracer technology were also used for the performance test of the clarifier in a wastewater treatment plant and for the leak detection in reservoirs. From the experience of case studies on radiotracer experiment in waste water treatment facilities, 'The New Excellent Technology' is granted from the ministry of environment. For future technology, preliminary research for industrial gamma transmission and emission tomography which are new technology combined with radioisotope and image reconstruction are carried out

  17. Finding of region of interest in radioisotope scintigraphy's images

    International Nuclear Information System (INIS)

    Glazs, A.; Lubans, A.

    2003-01-01

    The paper is about some problems, which arise, when physicians try to make diagnosis, using information from pictures, which are obtained at radioisotope scintigraphy. The algorithm of obtaining pictures' sets (called GFR) is described in this paper. The possible mistakes in diagnosis are also described. One reason of the mistakes is wrong detection the investigated organ's location. The new method is suggested for detection of organ's location in radioisotope scintigraphy's images' sets. Using of dynamic curves of pixels' intensities is suggested for solving of this problem. It is shown, why using of maximums of such curves is impossible for finding of the investigated organ's location in radioisotope scintigraphy's images sets. The using of integral expression is suggested to solve the problem. The suggested method allows finding and selecting of investigated organ's location in image's sequences (correction is not available in the existing methods). The results of using this method are present. The method can work fully automatically or with manual setting of threshold. (authors)

  18. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  19. Activities of the IAEA on the use of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Shalnov, A V [International Atomic Energy Agency, Vienna (Austria). Div. of Research and Lab.

    1976-06-01

    The program of the IAEA related to the use of radioisotopes and radiation is concentrated in the Department of Research and Isotopes, which includes the Joint FAO/IAEA of Atomic Energy in Food and Agriculture, the Life Sciences Division, and the Division of Research and Laboratories. The following matters are described: hydrology of water systems using stable isotopes, research on CPXE (charged-particle X-ray emission), Regional Cooperative Agreements, Nuclear Methods in Environmental Research, and guidance to developing countries in the medical applications of radioisotopes.

  20. A Review of the Production of ''Special'' Radioisotopes

    International Nuclear Information System (INIS)

    Stang, L.G. Jr.

    1963-01-01

    Six useful characteristics of radioisotopes and advantages which may be taken of them are cited briefly, with examples. The Information Sheet announcing this Seminar listed four advantages of short-lived over long-lived isotopes. Two other reasons why owners of small research reactors should concern themselves with short half- life isotopes are economy and particular suitability for production, the latter being due to the pronounced effect of half-life on the net rate of production. Besides short half-life, type and energy of emitted radiation should be of concern to producers of isotopes. Nine advantages of a nuclear reactor over a particle accelerator for radioisotope production are outlined. Following this general orientation, a survey of unusual or less frequently used production techniques is presented. These include: (n, p) reactions and secondary reactions such as (t, n) and (t, p) induced by thermal neutrons, various techniques for obtaining useful fluxes of fast neutrons with which to effect other reactions, recoil techniques including classic Szilard-Chalmers reactions, use of charged wires to collect short-lived daughters of gaseous parents, parent-daughter milking system, parasitic irradiations, possible use of ''knocked- on'' protons or deuterons (from the moderator) as a means of effecting reactions such as (p,n), (d,n), etc. and the possible use of circulating ''loops'' in reactors with which to utilize the radiation from ultra-short-lived radioisotopes such as Ag 110 , In 114 , 116 , Dy 155m , etc. Although not a production technique, the possibility of using certain stable isotopes (e. g. of silver) as tracers which can be readily detected via subsequent activation is mentioned. Production figures for Brookhaven's ''special'' radioisotopes are cited to show differences in long- and short-term fluctuations among these isotopes, which are also compared as a class to those in heavier demand supplied by Oak Ridge. Present production methods of all

  1. Historical sketch of the discovery, production, and application of radioisotopes

    International Nuclear Information System (INIS)

    Williams, C.

    1975-01-01

    The Joliot-Curies made the first artificial radioisotope ( 30 P) by bombarding aluminum with alpha particles. The development of the cyclotron and other high-energy particle accelerators in the early 1930's led to the production of numerous radioisotopes in measurable quantities. By the beginning of the 1950's, with the abundant neutron fluxes available at the U. S. Atomic Commission reactors, radioisotopes of many species really became abundant. Naturally occurring radioactive lead had been used very sparingly as tracers as far back as 1918 in determining chemical solubility and in 1923 in plant uptake from lead solutions. Now many new uses were developed and tested as tracers in medical diagnosis, agricultural, and industrial chemical and metallurigical processes. Many therapeutic applications were tested. The industrial labs developed thickness and level gauges for control of various manufacturing processes. Cobalt gamma-ray irradiators were developed for medical therapy and have also been used for sterilization of surgical instruments and materials, for food preservation, and for initiation of certain chemical reactions. The most significant development in the 1960's was the rapidly increasing role of private industry in taking over the development, production, sales, as well as research, into new methods of production and applications of radioisotopes

  2. The control of radioisotopes in Canada

    International Nuclear Information System (INIS)

    Hamel, P.E.

    1980-01-01

    The Regulations applicable to the control of radioisotopes in Canada are reviewed. The administrative procedures are described, the definition of atomic radiation workers clarified and the means for inspections and compliance indicated. An outline is provided of the main revisions currently under consideration. (author) [fr

  3. Chemical coloring on stainless steel by ultrasonic irradiation.

    Science.gov (United States)

    Cheng, Zuohui; Xue, Yongqiang; Ju, Hongbin

    2018-01-01

    To solve the problems of high temperature and non-uniformity of coloring on stainless steel, a new chemical coloring process, applying ultrasonic irradiation to the traditional chemical coloring process, was developed in this paper. The effects of ultrasonic frequency and power density (sound intensity) on chemical coloring on stainless steel were studied. The uniformity of morphology and colors was observed with the help of polarizing microscope and scanning electron microscopy (SEM), and the surface compositions were characterized by X-ray photoelectric spectroscopy (XPS), meanwhile, the wear resistance and the corrosion resistance were investigated, and the effect mechanism of ultrasonic irradiation on chemical coloring was discussed. These results show that in the process of chemical coloring on stainless steel by ultrasonic irradiation, the film composition is the same as the traditional chemical coloring, and this method can significantly enhance the uniformity, the wear and corrosion resistances of the color film and accelerate the coloring rate which makes the coloring temperature reduced to 40°C. The effects of ultrasonic irradiation on the chemical coloring can be attributed to the coloring rate accelerated and the coloring temperature reduced by thermal-effect, the uniformity of coloring film improved by dispersion-effect, and the wear and corrosion resistances of coloring film enhanced by cavitation-effect. Ultrasonic irradiation not only has an extensive application prospect for chemical coloring on stainless steel but also provides an valuable reference for other chemical coloring. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Standardization and improvement of safety for radioisotope equipped instruments

    International Nuclear Information System (INIS)

    Sumi, Tetsuo

    1980-01-01

    The safety for radioisotope-equipped instruments is considered. The one is the safety for the source assembly. The radioisotopes employed for radioisotope-equipped instruments are sealed sources which are used in the state of being contained in the enclosures. Many of the enclosures are provided with shutter mechanism for the purpose of emitting radiation only during the period required. If the possible troubles that might lead to the accidents are sampled out of the results of field operation of radiation instruments, and the safety measures for source enclosures are considered in connection with these troubles, it is no exaggeration to say that the safety for source enclosures has been maintained by preventing the critical accidents by the management of users and the cooperation of manufactures though there were the chance for investigating the safety in the common field and the establishment of JIS Z 4614 standard. Another consideration is concerned with the measures to improve the safety. No accident in the past never guarantees no accident in the future. Accumulation of experience is most effective for those measures, and the more experiences the better. It may be most effective that the manufacturers disclose their experiences each other from the wide outlook overcoming the barrier of trade secret. Fortunately, such consciousness has risen since a few years ago, and the investigation group is doing the works in the Japan Radioisotope Association. On the other hand, the reasonable revision of the radiation injury prevention law is desired. (Wakatsuki, Y.)

  5. Planning For Multiple NASA Missions With Use Of Enabling Radioisotope Power

    Energy Technology Data Exchange (ETDEWEB)

    S.G. Johnson; K.L. Lively; C.C. Dwight

    2013-02-01

    Since the early 1960’s the Department of Energy (DOE) and its predecessor agencies have provided radioisotope power systems (RPS) to NASA as an enabling technology for deep space and various planetary missions. They provide reliable power in situations where solar and/or battery power sources are either untenable or would place an undue mass burden on the mission. In the modern era of the past twenty years there has been no time that multiple missions have been considered for launching from Kennedy Space Center (KSC) during the same year. The closest proximity of missions that involved radioisotope power systems would be that of Galileo (October 1989) and Ulysses (October 1990). The closest that involved radioisotope heater units would be the small rovers Spirit and Opportunity (May and July 2003) used in the Mars Exploration Rovers (MER) mission. It can be argued that the rovers sent to Mars in 2003 were essentially a special case since they staged in the same facility and used a pair of small launch vehicles (Delta II). This paper examines constraints on the frequency of use of radioisotope power systems with regard to launching them from Kennedy Space Center using currently available launch vehicles. This knowledge may be useful as NASA plans for its future deep space or planetary missions where radioisotope power systems are used as an enabling technology. Previous descriptions have focused on single mission chronologies and not analyzed the timelines with an emphasis on multiple missions.

  6. Radioisotope application to studies of copper electrolytic refining

    International Nuclear Information System (INIS)

    Shul'ts, U.; Lange, Kh.; Gajdel', B.

    1976-01-01

    Silver and selenium behaviour was studied using sup(110m)Ag and 75 Se radioisotopes in the copper electrolysis process. sup(110m)Ag and 75 Se distribution in the electrorefining products was also studied. It was found that Ag/Se mass ratio affected greatly the silver content in the copper cathode. It was found that the tracer technique made it possible to determine 0,1gSe/tCu and 1gAg/t Cu simultaneously and accurately with small material and time expenses. Using sup(110m)Ag radioisotope, the reduction in electrolyte silver content dependent on time may be determined quickly and accurately

  7. Radiation surveillance procedure during veterinary application of radioisotope

    International Nuclear Information System (INIS)

    Kamaldeep; Bhaktivinayagam, A.; Singh, Sanjay Kumar

    2012-01-01

    Radioisotopes have found wide applications in the field of biomedical veterinary nuclear medicine and research. Radiation safety issues during internal administration of radioisotopes to laboratory animals, unlike human use, are far more challenging and requires stringent, well planned and an organized system of radiation protection in the animal house facility. In this paper, we discuss our experience during veterinary research experiments involving use, handling and administration of liquid sources of 131 I. With extensive radiation protection surveillance and application of practical and essential radiation safety and hygiene practices, the radiation exposure and contamination levels during the veterinary application of isotopes can be kept ALARA

  8. Radioisotope techniques for problem solving in the offshore oil and gas industry

    International Nuclear Information System (INIS)

    Charlton, J.S.; Hurst, J.A.

    1994-01-01

    Radioisotope technology has been used for almost half a century by the oil and gas industry to solve problems and to help optimize process operations. The use of radioactive isotopes to investigate the effectiveness of well stimulation procedures and to measure the sweep-out patterns of oil and gas in secondary recovery process is well known. The applications of radioisotopes to study features of plant and process operation has been less widely reported though the economic benefits deriving from such applications are very great. Nevertheless, there has been continuous development in the range of application and in the design of equipment to facilitate the use of the technology at remote environments such as an oil or gas platform. Some indication of the current usage of radioisotope techniques may be obtained from examination of Table I, which lists projects carried out in the UK's North Sea fields by ICI Tracerco, which is the world's largest radioisotope applications service group

  9. Results with radioisotope techniques in veterinary science in Hungary

    International Nuclear Information System (INIS)

    Pethes, Gyoergy

    1983-01-01

    Radioisotopes have been applied to veterinary science in Hungary since the fifties. A short chronologic review on the development of isotope technology is given emphasizing the possibilities offered by the application of closed and open radiation sources, of instrumental neutron activation analysis and atomic absorption spectroscopy, and in vitro nuclear procedures which include competitive protein-binding analysis and radioimmunoassay. The progesterone test, applicable to diagnose the pregnancy of cattles, is carried out generally by RIA. Radioisotopic methods are applied also to determine the thyroid function of cattles, swines and domestic fowls. (V.N.)

  10. Radioisotope relay instrument

    International Nuclear Information System (INIS)

    Pozdnyakov, V.N.; Sazonov, O.L.; Taksar, I.M.; Tesnavs, Eh.R.; Yanushkovskij, V.A.

    1974-01-01

    The paper describes a radioisotope relay device containing a radiation source, a detector, an electronic relay block with a comparative threshold mechanism. The device differs from previously known ones in that, for the purpose of increasing stability and speed of action, the electronic relay block is a separate unit and contains two threshold pulse generators which are joined up, across series-connected ''and'' and ''or'' elements, with one of the inputs of the comparative threshold mechanism, whose second input is connected with a detector and whose outputs are connected with a relay element connected by feedback with the above-mentioned ''and'' elements. (author)

  11. Theory of Scanning and Imaging of Radioisotope Distributions; Theorie de la Scintigraphoe a Balayage ou Fixe; Teoriya skennirovaniya i izobrazhenie raspredeleniya radioizotopov; Teoria de la Exploracion y de la Obtencion de Imagenes de Distribuciones Radioisotopicas

    Energy Technology Data Exchange (ETDEWEB)

    Cassen, B. [Department of Biophysics and Nuclear Medicine, University of California, Los Angeles, CA (United States)

    1964-10-15

    In a published paper, the author has presented a simplified basic theory of the quantitative performance characteristics of radioisotope imaging and scanning systems. A ''figure of merit'' is derived, depending partly on the instrument characteristics and partly on the methodology utilized. The factors involved in the figure of merit are: the count-rate sensitivity of the detector per unit solid angle, subtended from a resolution element, the solid angle subtended from a resolution element, the number of resolution elements viewed simultaneously, the number of resolution elements in the total field scanned or imaged, the dose concentration, the total time taken to produce an image or scan and the background count-rate. In the present presentation the basic theory is further refined and discussed to take into account factors such as ''depth-of-focus'' resolution, variable speed or variable dwell scanning, possibilities of variable or automatically variable resolution, relative resolvability of ''cold'' and ''hot'' nodules, field size and use of special radioisotopes and types of detectors. Also, a discussion is presented on the handling and processing of data arising from scanning and imaging techniques. The relative merits of background eliminators and contrast enhancement procedures such as photoscanning and colour scanning are analysed. The advantages and possible disadvantages of tape recording original data and the repeated playback through contrast and background processing circuits is discussed. Some experimentally determined figure-of-merit data are presented on a widely used commercialscanner and on some new developments, especially a new high quantum utilization scanner, which is briefly described in the above-mentioned article and has since undergone further development, improvement and testing. (author) [French] Dans une publication, l'auteur a expose une theorie fondamentale simplifiee des caracteristiques quantitatives de rendement des divers systemes

  12. Radioisotope study of Eustachian tube

    International Nuclear Information System (INIS)

    De Rossi, G.; Campioni, P.; Vaccaro, A.

    1988-01-01

    Radioisotope studies of Eustachian tube are suggested in the preoperative phase of tympanoplasty, in order to assess tubal drainage and secretion. The use of gamma camera fitted to a computer allowed the AA, to calculate some semi-quantitative parameters for an exact assessment of the radioactivity transit from the tympanic cass up to the pharyngeal cavity, throughout the Eustachian tube. (orig.) [de

  13. Mathematical models and accuracy of radioisotope gauges

    International Nuclear Information System (INIS)

    Urbanski, P.

    1989-01-01

    Mathematical expressions relating the variance and mean value of the intrinsic error with the parameters of one and multi-dimensional mathematical models of radioisotope gauges are given. Variance of the intrinsic error at the model's output is considered as a sum of the variances of the random error which is created in the first stages of the measuring chain and the random error of calibration procedure. The mean value of the intrinsic error (systematic error) appears always for nonlinear models. It was found that the optimal model of calibration procedure not always corresponds to the minimal value of the intrinsic error. The derived expressions are applied for the assessment of the mathematical models of some of the existing gauges (radioisotope belt weigher, XRF analyzer and coating thickness gauge). 7 refs., 5 figs., 1 tab. (author)

  14. Health problems of industrial applications of radioisotopes

    International Nuclear Information System (INIS)

    Kudrna, J.

    1976-01-01

    Radiation hygiene problems of industrial radioisotope applications are discussed. The observance of regulations is emphasised. Radiation protection is based on the principle of preventing early radiation damage and limiting late radiation damage to an acceptable level. The basic requirement is that the cumulated dose should be as low as possible, i.e., as low as is practically feasible in considering economic and social aspects. Notices 59/72 and 65/72, Collection of Laws, rule that if the limit of 3/10 of the maximum permissible dose is likely to be reached, control zones should be defined and marked at places of work where radioisotopes are handled. The characteristics of such a control zone are listed and the measures to be taken in case of accident are outlined. (B.S.)

  15. A radioisotope-powered surface acoustic wave transponder

    International Nuclear Information System (INIS)

    Tin, S; Lal, A

    2009-01-01

    We demonstrate a 63 Ni radioisotope-powered pulse transponder that has a SAW (surface acoustic wave) device as the frequency transmission frequency selector. Because the frequency is determined by a SAW device, narrowband detection with an identical SAW device enables the possibility for a long-distance RF-link. The SAW transponders can be buried deep into structural constructs such as steel and concrete, where changing batteries or harvesting vibration or EM energy is not a reliable option. RF-released power to radioisotope- released power amplification is 10 8 , even when regulatory safe amounts of 63 Ni are used. Here we have achieved an 800 µW pulse (315 MHz, 10 µs pause) across a 50 Ω load every 3 min, using a 1.5 milli-Ci 63 Ni source

  16. The future of medical radioisotope supply

    International Nuclear Information System (INIS)

    Peykov, Pavel

    2014-01-01

    The NEA and its High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) have been actively examining the causes of supply shortages of the most widely used isotope in medical diagnostic imaging, technetium-99m ( 99m Tc), and its parent isotope molybdenum-99 ( 99 Mo). As a result of this examination, the HLG-MR has developed a policy approach that includes principles and supporting recommendations to address the causes of these supply shortages. Six policy principles were agreed by the HLG-MR in March 2011. These are implementation of full-cost recovery and outage reserve capacity (ORC) for 99 Mo production, a government role in the market, conversion to low-enriched uranium targets, international collaboration and periodic reviews of the supply chain. This article describes progress made in the implementation of the six principles and examines the projected global capacity for medical radioisotope production in the near future. (author)

  17. Radioisotopes for nuclear medicine: the future

    International Nuclear Information System (INIS)

    Carr, S.W.

    1998-01-01

    Full text: Nuclear medicine occupies an important niche in the spectrum of medical capability. Since its initial application on a routine basis over 30 years ago its importance has continued to grow. For example, it is expected that over 430,000 Australians will have a nuclear medicine procedure in 1998. Current procedures using nuclear medicine are mainly concerned with diagnosis of oncology, cardiology and neurology. The main radioisotope used in nuclear medicine is Tc 99m, which is produced by a 'so called' Mo-Tc 99m generator. Other isotopes which currently find routine use are Ga-67, Th-201 and I-131. The selective uptakes by particular organs or structures is facilitated by the use of 'cold kits' which after the chemistry of the radioisotope many of the recent advances have been concerned with increasing the selectivity for a particular organ structure. Several of these new agents show increased selectivity using antibody a peptide recognition units

  18. [Diagnoses of rice nitrogen status based on characteristics of scanning leaf].

    Science.gov (United States)

    Zhu, Jin-Xia; Deng, Jin-Song; Shi, Yuan-Yuan; Chen, Zhu-Lu; Han, Ning; Wang, Ke

    2009-08-01

    In the present research, the scanner was adopted as the digital image sensor, and a new method to diagnose the status of rice based on image processing technology was established. The main results are as follows: (1) According to the analysis of relations between leaf percentage nitrogen contents and color parameter, the sensitive color parameters were abstracted as B, b, b/(r+g), b/r and b/g. The leaf position (vertical spatial variation) effects on leaf chlorophyll contents were investigated, and the third fully expanded leaf was selected as the diagnosis leaf. (2) Field ground data such as ASD were collected simultaneously. Then study on the relationships between scanned leaf color characteristics and hyperspectral was carried out. The results indicated that the diagnosis of nitrogen status based on the scanned color characteristic is able to partly reflect the hyperspectral properties. (3) The leaf color and shape features were intergrated and the model of diagnosing the status of rice was established with calculated at YIQ color system. The distinct accuracy of nitrogen status was as follows: N0: 74.9%; N1 : 52%; N2 : 84.7%; N3 : 75%. The preliminary study showed that the methodology has been proved successful in this study and provides the potential to monitor nitrogen status in a cost-effective and accurate way based on the scanned digital image. Although, some confusion exists, with rapidly increasing resolution of digital platform and development of digital image technology, it will be more convenient for larger farms that can afford to use mechanized systems for site-specific nutrient management. Moreover, deeper theory research and practice experiment should be needed in the future.

  19. Risk of internal contamination of workers employed in radioisotope laboratories in Poland

    Energy Technology Data Exchange (ETDEWEB)

    Adamiak-Ziemba, J.; Domanski, T.; Doniec, J.

    1981-01-01

    It was established that in Poland 247 radioisotope laboratories use open radiation sources. These laboratories have not yet been covered by the internal system of control of inner contamination. The number of workers having contact with radioisotopes amounts to 1987. Frequently this is work in contact with several radioisotopes (from 1 to 17). Most workers are exposed to tritium (over 500 workers), /sup 14/C (over 500), /sup 125/I and /sup 131/I, /sup 32/P, /sup 51/Cr, 99mTc (over 100), isotopes belonging to radiotoxicity groups 2, 3 and 4. In the radiotoxicity group 1 the most workers were exposed to /sup 226/Ra (52).

  20. Regulations concerning the radionuclides uses in France; Reglementation de l'utilisation des radioisotopes en France

    Energy Technology Data Exchange (ETDEWEB)

    Vergne, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Bugnard, L [Institut national d' Hygiene (France)

    1955-07-01

    The progress in the uses of radioisotopes has been conditioned by increasing the number of trained workers and researchers and developing theoretical teaching in universities since 1950 in France as well as developing a national control of the distribution and uses of radioisotopes. With the large diffusion and development of radioisotopes uses and applications, new rules and regulations came to control the importation, exportation, transport and utilization of radioisotopes. In the first part, it described the different French laws since 1934 and their successive modifications which ruled on the production, manipulation and utilization of radioisotopes. An inter-ministerial committee was created in 1952 to advise and inform of all the questions related to the preparation, importation, exportation, possession and distribution of radioisotopes. The transport regulations are in constant evolution and has got to meet with international recommendations. It distinguished three different type of transport: road, river and railway transport, postal transport and finally air transport. All the different transports have their specific packaging, maximum transportable quantity, maximum material intensity and labelling requirements. The regulations about customs duties are specified as well as the administrative formalities for non natural radioisotopes importation. Since 1950, diseases caused by irradiation to natural or artificial radioactive materials are recognised as professional diseases and a table of the actual regulations is presented. (M.P.)

  1. Radioisotope electric propulsion of sciencecraft to the outer Solar System and near-interstellar space

    International Nuclear Information System (INIS)

    Noble, R.J.

    1999-01-01

    Radioisotopes have been used successfully for more than 25 years to supply the heat for thermoelectric generators on various deep-space probes. Radioisotope electric propulsion (REP) systems have been proposed as low-thrust ion propulsion units based on radioisotope electric generators and ion thrusters. The perceived liability of radioisotope electric generators for ion propulsion is their high mass. Conventional radioisotope thermoelectric generators have a specific mass of about 200 kg/kW of electric power. Many development efforts have been undertaken with the aim of reducing the specific mass of radioisotope electric systems. Recent performance estimates suggest that specific masses of 50 kg/kW may be achievable with thermophotovoltaic and alkali metal thermal-to-electric conversion generators. Powerplants constructed from these near-term radioisotope electric generators and long-life ion thrusters will likely have specific masses in the range of 100 to 200 kg/kW of thrust power if development continues over the next decade. In earlier studies, it was concluded that flight times within the Solar System are indeed insensitive to reductions in the powerplant specific mass, and that a timely scientific program of robotic planetary rendezvous and near-interstellar space missions is enabled by primary electric propulsion once the powerplant specific mass is in the range of 100 to 200 kg/kW. Flight times can be substantially reduced by using hybrid propulsion schemes that combine chemical propulsion, gravity assist, and electric propulsion. Hybrid schemes are further explored in this article to illustrate how the performance of REP is enhanced for Pluto rendezvous, heliopause orbiter, and gravitational lens missions

  2. Production of Radioisotopes and Radiopharmaceuticals at the Dalat Nuclear Research Reactor

    International Nuclear Information System (INIS)

    Duong Van Dong; Pham Ngoc Dien; Bui Van Cuong; Mai Phuoc Tho; Nguyen Thi Thu; Vo Thi Cam Hoa

    2014-01-01

    After reconstruction, the Dalat Nuclear Research Reactor (DNRR) was inaugurated on March 20th, 1984 with the nominal power of 500 kW. Since then the production of radioisotopes and labelled compounds for medical use was started. Up to now, DNRR is still the unique one in Vietnam. The reactor has been operated safely and effectively with the total of about 37,800 hrs (approximately 1,300 hours per year). More than 90% of its operation time and over 80% of its irradiation capacity have been exploited for research and production of radioisotopes. This paper gives an outline of the radioisotope production programme using the DNRR. The production laboratory and facilities including the nuclear reactor with its irradiation positions and characteristics, hot cells, production lines and equipment for the production of Kits for labelling with 99m Tc and for quality control, as well as the production rate are mentioned. The methods used for production of 131 I, 99m Tc, 51 Cr, 32 P, etc. and the procedures for preparation of radiopharmaceuticals are described briefly. Status of utilization of domestic radioisotopes and radiopharmaceuticals in Vietnam is also reported. (author)

  3. Trace element deficiency and its diagnosis by radioisotope injection

    International Nuclear Information System (INIS)

    Kirchgessner, M.; Schwarz, F.J.

    1976-01-01

    The metabolism of trace elements is subject to certain mechanisms of homeostatic regulation. The supply status of the trace elements, iron, copper, zinc and manganese has definite effects on their respective extent of intestinal absorption, retention and intestinal excretion. Experimental studies show that there is an increase in intestinal absorption and retention, and a decrease in turnover rate and endogenous excretion of these trace elements in response to deficient dietary intake. On the basis of these results, three models are discussed for the use of radioisotopes in the diagnosis of situations of trace element deficiency: (1) Determination of the intestinal absorption of an orally administered radioisotope dose by measuring the activity of blood; (2) Determination of the retention of a parenterally administered dose in blood or plasma; and (3) Determination of the endogenous faecal excretion of a parenterally administered dose. The advantages and disadvantages of these models are discussed. Determination of the endogenous secretion of the trace element after intravenous injection of its radioisotope may be considered as the simplest and most informative method. (author)

  4. Present status and prospect of radiation and radioisotopes in China

    International Nuclear Information System (INIS)

    Zhou, Yong-Tian

    1986-01-01

    Production and application of radioisotopes in China started almost thirty years ago. At present there are 20 units producing more than 700 radioisotope products. This report outlines the present status and prospect of radiation and radioisotopes in some major areas. Remarkable achievements have been made in agriculture using nuclear technology. More than 70 new varieties or strains of cultivated plants have been bred by inducing mutation through irradiation. A new variety of silkworm bred by irradiation has unique characteristics such as high and stable yield. Application of radioisotopes in medical research and clinical practice began in 1956 and radionuclides have been progressively used in diagnosis and treatment of diseases. The most common radionuclide used in therapy is iodine-131 for hyperthyroidism. Isotope-tracer technique and activation analysis play an important role in the study of traditional Chinese medicine. Isotope methods in China have been used in many industrial branches, such as textile, plastic and printing, but not very widely now. The nation has produced more than 2,000 sets of nuclear radiation measuring instruments, which become important parts of industrial automation control. The radiation processing research started in the end of 1950's. Food irradiation research has been going on in a good cooperation of different branches. Now China is planning to set up some plants to produce gamma irradiated disposal syringes and other medical devices. (Nogami, K.)

  5. Efficient, Long-Lived Radioisotope Power Generator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Radiation Monitoring Devices, Inc., (RMD) proposes to develop an alternative very long term, radioisotope power source with thermoelectric power conversion with...

  6. Radioisotope measurement system; Sistema de medicion de radioisotopos

    Energy Technology Data Exchange (ETDEWEB)

    Villanueva Ruibal, Jose [Comision Nacional de Energia Atomica, Ezeiza (Argentina).Centro Atomico Ezeiza

    2007-07-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [Spanish] Un sistema de instrumentacion instalado en el L.M.R. (Centro Atomico Ezeiza de la CNEA) mide en amplio rango la actividad del decaimiento nuclear de radioisotopos. Permite caracterizar una amplia gama de radioistopos de variados niveles de actividad. Tanto el hardware de medicion como el software de operacion han sido desarrollados y construidos en el Dept. Instrumentacion y Control. El trabajo esboza la conformacion del sistema y su concepto de operacion, describe caracteristicas de disenio, construccion y del tratamiento del error, comenta resultados de ensayos y provee recomendaciones de uso. Pruebas de medicion realizadas empleando diversos nucleidos comprobaron que el sistema funciona en forma satisfactoria y su operacion es amigable. (autor)

  7. Improvement of radioisotope production technology

    International Nuclear Information System (INIS)

    Li Yongjian

    1987-01-01

    The widespreading and deepgoing applications of radioisotopes results the increasing demands on both quality and quantity. This in turn stimulating the production technology to be improved unceasingly to meet the different requirements on availability, variety, facility, purity, specific activity and specificity. The major approaches of achieving these improvements including: optimizing mode of production; enhancing irradiation conditions; amelioration target arrangement; adapting nuclear process and inventing chemical processing. (author)

  8. Advanced Stirling Radioisotope Generator Life Certification Plan

    Science.gov (United States)

    Rusick, Jeffrey J.; Zampino, Edward J.

    2013-01-01

    An Advanced Stirling Radioisotope Generator (ASRG) power supply is being developed by the Department of Energy (DOE) in partnership with NASA for potential future deep space science missions. Unlike previous radioisotope power supplies for space exploration, such as the passive MMRTG used recently on the Mars Curiosity rover, the ASRG is an active dynamic power supply with moving Stirling engine mechanical components. Due to the long life requirement of 17 years and the dynamic nature of the Stirling engine, the ASRG project faced some unique challenges trying to establish full confidence that the power supply will function reliably over the mission life. These unique challenges resulted in the development of an overall life certification plan that emphasizes long-term Stirling engine test and inspection when analysis is not practical. The ASRG life certification plan developed is described.

  9. Production and application of radioisotopes in Asian Countries

    International Nuclear Information System (INIS)

    He Youfeng

    1997-01-01

    Production and application of radioisotopes in some Asian countries including Bangladesh, India, Indonesia, Iran, Japan, Republic of Korea, Malaysia, Pakistan, Philippines, Thailand, Uzbekistan, and Viet Nam are introduced

  10. The use of radioisotopes in medicine and medical research, Australia 1947-73

    Energy Technology Data Exchange (ETDEWEB)

    Korszniak, N

    1994-12-01

    On March 31, 1994, an article appeared in the Melbourne Age claiming that after the Second World War `hundreds of people were injected with radioactive materials in medical experiments that continued in Australian hospitals until the 1960s. Similar reports subsequently appeared in other newspapers and on the television and radio news. The archival records held at the Australian Radiation Laboratory (ARL) pertaining to the medical uses of radioisotopes during the period 1947-1973 have been examined to ascertain the nature of radioisotope use, and in the case of experimental procedures, any ethical considerations. The material examined indicates that the distribution and medical use of radioactive isotopes was stringently controlled by the Radio-isotope Standing Committee (established by the National Health and Medical Research Council (NHMRC) in 1947 to oversee this area) until its disbandment in 1973, when the responsibility for regulation of the use of radioactive isotopes for medical purposes in Australia passed to the Therapeutic Goods Administration. A database, showing details of over 500 radioisotope use in Australia between 1947-1973 is given in Appendix III . (author) refs., tabs.

  11. The use of radioisotopes in medicine and medical research, Australia 1947-73

    International Nuclear Information System (INIS)

    Korszniak, N.

    1994-12-01

    On March 31, 1994, an article appeared in the Melbourne Age claiming that after the Second World War 'hundreds of people were injected with radioactive materials in medical experiments that continued in Australian hospitals until the 1960s. Similar reports subsequently appeared in other newspapers and on the television and radio news. The archival records held at the Australian Radiation Laboratory (ARL) pertaining to the medical uses of radioisotopes during the period 1947-1973 have been examined to ascertain the nature of radioisotope use, and in the case of experimental procedures, any ethical considerations. The material examined indicates that the distribution and medical use of radioactive isotopes was stringently controlled by the Radio-isotope Standing Committee (established by the National Health and Medical Research Council (NHMRC) in 1947 to oversee this area) until its disbandment in 1973, when the responsibility for regulation of the use of radioactive isotopes for medical purposes in Australia passed to the Therapeutic Goods Administration. A database, showing details of over 500 radioisotope use in Australia between 1947-1973 is given in Appendix III . (author)

  12. Development of a segmented gamma ray scanning system

    International Nuclear Information System (INIS)

    Zhu Rongbao; Tan Yajun; Yuan Xiaoxin

    1994-01-01

    A segmented gamma ray scanning system is developed for the purposes of non-destructive assay of the contents of uranium, plutonium or fission products existing in packed low density or medium density nuclear residuals, scrapes or wastes. The near field three-dimensional model for computing CF(AT) is used for cylindrical sample and container, the system developed consists of a transmission source wheel, a rotatable scanning plate, a beam shutter, and annular shielding body, stepping motors and control system, HPGe detector, nuclear electronics and computer. The full scale scanning of samples, spectrum accumulation and data reduction could be fulfilled automatically according to preset standard procedures. The radioisotopes of 169 Yb and 75 Se and used as the transmission sources for assaying 235 U and potential 239 Pu respectively. The calibration experiments using 1 liter solution sample of 192 Ir and 235 U is performed. The standard deviations were obtained for 192 Ir γ rays of 295 keV, 308 keV and 316 keV are +- 0.41%, +- 0.29% and +-0.42% respectively. The standard divination for 235 U 185 keV γ ray is +- 0.62%

  13. A Survey on the Usage and Demand of Medical Radioisotope and Radiopharmaceuticals in Malaysia

    International Nuclear Information System (INIS)

    Muhammad Fakhrurazi Ahmad Fadzil; Siti Selina Abdul Hamid; Siti Najila Mohd Janib; Azahari Kasbollah; Syed Asraf Fahlawi Wafa

    2016-01-01

    Medical radioisotope is a small quantity of radioactive substance used for the purpose of diagnostic and therapy of various diseases. In Malaysia, the emerging of new nuclear medicine centers or institutions in both government and private sectors rose abruptly for the past few years. Currently, there are no data available on the usage and demand of these medical radioisotope or radiopharmaceuticals. The aim of this study is to assess current medical radioisotopes and radiopharmaceuticals usage and also to provide data on current medical radioisotope and radiopharmaceuticals demand for both private and government hospitals or institutions in Malaysia. A survey for a period of 3 months was conducted across Malaysia. The survey was divided into five (5) main parts and it was distributed among health care professionals involved working with medical radioisotope and radiopharmaceuticals in private, government and university based hospitals or institutions and was distributed manually either by hand, mail or e-mail. Data is presented in either pie chart or bar chart. Survey results found out that the highest demand and the highest usage among all radioisotopes are Technetium-99m and radioiodine isotopes such as the iodine-131, iodine-131 MIBG, iodine-123 and iodine-123 MIBG. Technetium-99m is the backbone of nuclear medicine whereby more than 80 % of Nuclear Medicine services utilize this radioisotope. Technetium-99m supply chain is unstable globally and in coming future, two main reactors that produce 60 % of world Molybdenum-99 will shut down and the supply of molybdenum-99 will be disrupted. In radioiodine services, currently, Iodine-123 cannot be obtained in Malaysia and neighboring countries due to its short half-life. Iodine-123 is useful in diagnostic of thyroid related diseases. As for PET services, the highest demands are F-18 FDG and gallium-68 Generator. It is important for Malaysia to self-produced medical radioisotope and radiopharmaceuticals to meet the

  14. Radioisotope licence application: Fixed nuclear gauges

    International Nuclear Information System (INIS)

    1995-09-01

    This guide will assist you in completing and filing an application for a new licence or licence renewal for fixed nuclear gauges in accordance with the Atomic Energy Control Regulations and radioisotope licensing policies. It also provides some of the background information that you will require in order to safely use radioactive materials

  15. Economical and technical feasibility study of some radioisotopes production for medical application

    International Nuclear Information System (INIS)

    Souza, A.L.A.B. de.

    1985-01-01

    The economical and technical feasibility study of the production in reactors of some radioisotopes most used in medicine, are presented. The clinical applications of each radioisotope as well as its radioactive concentrations and specific activities are related. Irradiation procedures based in the foregoing data are given. Part of the study is dedicated to quality control. (M.A.C.) [pt

  16. Radioisotopes in sedimentology

    International Nuclear Information System (INIS)

    Courtois, G.

    1967-01-01

    Radioisotopes have two main uses in sedimentology: they are used for the study of sediment movements in rivers and seas, and for continuous measurements of the amount of sediment suspended in a given medium. These two uses are considered in detail, and brief accounts given of some other uses. Study of sediment movements. After describing the basic technique used in sediment movement studies (injection of a labelled sediment or a simulator into the current, followed by tracking the radioactivity), the author enumerates as fully as possible the problems that can be solved with the help of this technique. Essentially, these problems fall into two groups: 1. Problems related to civil engineering works in coastal areas: the siltation of harbour channels and docks, the formation of banks and bars, the choice of sites for disposing of dredged sediment, the siting of ports, coastline protection, etc. Problems associated with civil engineering works in and near rivers; siting of the water intakes of hydroelectric and nuclear power stations, the effects of construction work on the transport of solids, the construction of dams, the protection of river banks, the construction of jetties, the siltation of lakes, etc. Problems common to these include the transport of effluent and the calibration of hydraulic models. The bibliography is based mainly on fairly recent references and on current research work. 2. Problems related to basic or applied research conducted mainly by universities and research centres: the study of the Quarternary of a particular region, pure sedimentology, the investigation of major sediment transport currents, the confirmation or refutation of transport theories, research into fundamental transport phenomena associated with channel experiments. After referring to the possible exploitation of natural tracers (contained in radioactive waste and fallout), the author discusses the technical aspects of using artificial tracers: the choice of radioisotope

  17. Radioisotopic methods for quality control of works and studies while constructing foundations and underground structures

    International Nuclear Information System (INIS)

    Smorodinov, M.I.

    1980-01-01

    The data on the use of radioisotope methods of quality control of various kinds of construction works when building foundations and underground constructions and when carrying out scientific research, are presented. Devices and equipment are described, their block diagrams are presented. The experience in using radioisotope devices to control the quality of construction works, is presented. The problems of economic effectivenes of works using radioisotope devices are solved

  18. Dose estimate of exposure to radioisotopes in molecular and cellular biology

    International Nuclear Information System (INIS)

    Onado, C.; Faretta, M.; Ubezio, P.

    1999-01-01

    A method for prospectively evaluating the annual equivalent doses and effective dose to biomedical researchers working with unsealed radioisotopes, and their classification, is presented here. Simplified formulae relate occupational data to a reasonable overestimate of the annual effective dose, and the equivalent doses to the hands and to the skin. The procedure, up to the classification of personnel and laboratories, can be made fully automatic, using a common spreadsheet on a personal computer. The method is based on occupational data, accounting for the amounts of each radioisotope used by a researcher, the time of exposure and the overall amounts employed in the laboratories where experiments are performed. The former data serve to forecast a contribution to the dose arising from a researcher's own work, the latter to a forecast of an 'environmental' contribution deriving simply from the presence in a laboratory where other people are working with radioisotopes. The estimates of the doses due to one's own radioisotope handling and to 'environment' were corrected for accidental exposure, considered as a linear function of the manipulated activity or of the time spent in the laboratories respectively, and summed up to give the effective dose. The effective dose associated with some common experiments in molecular and cellular biology is pre-evaluated by this method. (author)

  19. Background current of radioisotope manometer

    International Nuclear Information System (INIS)

    Vydrik, A.A.

    1987-01-01

    The technique for calculating the main component of the background current of radioisotopic monometers, current from direct collision of ionizing particles and a collector, is described. The reasons for appearance of background photoelectron current are clarified. The most effective way of eliminating background current components is collector protection from the source by a screen made of material with a high gamma-quanta absorption coefficient, such as lead, for example

  20. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  1. Management of radioactive wastes arising from the use of Australian radioisotopes

    International Nuclear Information System (INIS)

    Costello, J.M.

    1986-01-01

    The medical, industrial and research use of radioisotopes in Australia has given rise to approximately 30 m 3 of solid radioactive waste containing about 5 TBq of radioactivity. This waste is stored at State hospitals, universities and research centres. A further 10 m 3 of waste containing 300 GBq of radioactivity is stored by the Commonwealth at the St Mary's Munitions Filling factory. About 700 m 3 of waste containing 1.5 PBq of radioactivity resulting from operation of the HIFAR nuclear reactor and the production of radioisotopes is in storage at the Lucas Heights Research Establishment. The source, nature and rate of arising of these wastes is reviewed, together with national developments in waste classification, storage procedures and eventual disposal. Some research at Lucas Heights on the conditioning of radioisotope waste to facilitate disposal is briefly noted

  2. Contributions and future of radioisotopes in medical industrial, and space applications

    International Nuclear Information System (INIS)

    Tingey, G.L.; Wahlquist, E.J.

    1991-01-01

    Of the over 2300 isotopes identified to data, more than 1700 are short-lived with half-lives less than one day, 283 are stable, and 333 have a half-life between 1 day and 100,000 years. It is on this last group that the authors focus for the isotopes with useable radioactivity. Radioisotopes are used in a wide variety of applications including public health, medicine, industrial technology, food technology and packaging, agriculture, energy supply, and national security. The purpose of this paper is to provide an overview of some of the most extensive applications of radioisotopes including some observations of future uses. As for the future, we expect radioisotopes to contribute to a myriad of diverse applications to improve technological, scientific, and industrial endeavors, which include improving the length and quality of life through improved diagnosis and treatment of the human ills

  3. A new radioisotope facility for Thailand

    International Nuclear Information System (INIS)

    Horlock, K.

    1997-01-01

    The Thai Office of Atomic Energy for Peace (OAEP) is planning a new Nuclear Research Centre which will be located at Ongkharak, a greenfield site some 100 km North of Bangkok. General Atomics (GA) has submitted a bid for a turnkey contract for the core facilities comprising a Reactor to be supplied by GA, an Isotope Production Facility supplied by ANSTO and a Waste Processing and Storage Facility to be supplied by Hitachi through Marubeni. The buildings for these facilities will be provided by Raytheon, the largest constructor of nuclear facilities in the USA. The proposed Isotope Facility will consist of a 3000 m 2 building adjacent to the reactor with a pneumatic radioisotope transfer system. Hot cells, process equipment and clean rooms will be provided, as well as the usual maintenance and support services required for processing radiopharmaceutical and industrial products. To ensure the highest standards of product purity the processing areas will be supplied with clean air and operated at slightly positive pressure. The radioisotopes to be manufactured include Phosphorus 32 (S-32 [n,p]P-32), I-131(Te-130 [n,g]Te-131[p]I-131) for bulk, diagnostic capsules and therapeutic capsules, Iridium 192 (Ir-191[n,g]Ir-192) wire for radiotherapy and discs for industrial radiography sources and bulk Iodine 125 (Xe-124[n,g]Xe-125[β]I-125 for radioimmunoassay. The bid includes proposals for training OAEP staff during design and development at ANSTO's radioisotope facilities, and during construction and commissioning in Thailand. The entire project is planned to take four years with commencement anticipated in early 1997. The paper will describe the development of the design of the hot-cells, process equipment, building layout and ventilation and other services

  4. Miniaturized radioisotope solid state power sources

    Science.gov (United States)

    Fleurial, J.-P.; Snyder, G. J.; Patel, J.; Herman, J. A.; Caillat, T.; Nesmith, B.; Kolawa, E. A.

    2000-01-01

    Electrical power requirements for the next generation of deep space missions cover a wide range from the kilowatt to the milliwatt. Several of these missions call for the development of compact, low weight, long life, rugged power sources capable of delivering a few milliwatts up to a couple of watts while operating in harsh environments. Advanced solid state thermoelectric microdevices combined with radioisotope heat sources and energy storage devices such as capacitors are ideally suited for these applications. By making use of macroscopic film technology, microgenrators operating across relatively small temperature differences can be conceptualized for a variety of high heat flux or low heat flux heat source configurations. Moreover, by shrinking the size of the thermoelements and increasing their number to several thousands in a single structure, these devices can generate high voltages even at low power outputs that are more compatible with electronic components. Because the miniaturization of state-of-the-art thermoelectric module technology based on Bi2Te3 alloys is limited due to mechanical and manufacturing constraints, we are developing novel microdevices using integrated-circuit type fabrication processes, electrochemical deposition techniques and high thermal conductivity substrate materials. One power source concept is based on several thermoelectric microgenerator modules that are tightly integrated with a 1.1W Radioisotope Heater Unit. Such a system could deliver up to 50mW of electrical power in a small lightweight package of approximately 50 to 60g and 30cm3. An even higher degree of miniaturization and high specific power values (mW/mm3) can be obtained when considering the potential use of radioisotope materials for an alpha-voltaic or a hybrid thermoelectric/alpha-voltaic power source. Some of the technical challenges associated with these concepts are discussed in this paper. .

  5. An overview of computer models for pollutant transfer through the atmosphere, with special consideration for radioisotopes

    International Nuclear Information System (INIS)

    Zivanovic, M.; Djukanovic, J.; Davidovic, M.; Cekerevac, D.; Stankovic, S.

    2011-01-01

    Modern society is intrinsically connected with usage and production of radioisotopes, both for military and civilian applications. During the march of 2007, there were 443 active nuclear plants, unknown quantity of nuclear weapons and a huge number of industrial, medical and other facilities that possess and use radioisotopes for various purposes. With the widespread usage of radioisotopes, there comes a danger of accidental or planed release into the biosphere. This paper gives an overview of the models that can be used for prognosis or reconstruction of radioisotope transfer through the atmosphere in case of accidental or planned release [sr

  6. The Radioisotopes production in tunisia, presentation of the CNSTN project

    International Nuclear Information System (INIS)

    Ounalli, Leila

    2013-01-01

    Radio-isotopes required in medicine (nuclear medicine, neurology, cardiology, orthopedics) need a deep reflection and a scientific analysis of the problems related to the human health. The utilisation of radioisotopes in other fields such as chemistry, agriculture, industry, safety, earth sciences and environmental physics is also of great importance. In pharmaceutical companies, radioisotopes used in a laboratory of imaging for small animal to check the efficiency of drugs in vivo is touched upon in this presentation. Radioisotopes are also needed for different activities in platform dedicated to the training of radio pharmacist and radio biologist. The availability of radioisotopes in a research center such as the National Center of Nuclear Sciences and Technologies (NCNST) will improve the activity of existing skills and serve the country's development in the field of biomedical research. Tunisia has two projects of cyclotrons facilities: the first one is in the private sector and the second one is proposed by the NCNST. The realization of these projects requires a period of time estimated to two years for the feasibility study and two years more for constitution. In the meantime, it is necessary to establish a master's degree in radio-pharmacy / radio-biology to provide skills that may activate cyclotron facilities. One last test phase lasts 6 months to a year. The work within a cyclotron facility requires a rigorous and a lot of discipline (a little bit military) ordered by the risk of the isotope radioactive half-life and its radiation activity. Thus, it is necessary to provide to the staff, various training required for the functioning of the cyclotron. It is useful to insist on the importance of scientist's team which is going to put on the cyclotron and which consists of: radio-pharmacists, radio physicists experts in radiation protection, and engineer's operators of cyclotrons. It is useful to attract the attention that the specialties in the field of the

  7. Radioisotopes and food preservation against insects

    International Nuclear Information System (INIS)

    Hachem Ahmad, M.S.

    1998-01-01

    The book describes how to preserve food from harmful insects by using radioisotopes. It focusses on the impact of ionized radiation on the different stages of insect growth and on its metabolism and immunity. It also discusses the relationship between radiation doses and insect reproduction. It explains the various methods to detect the irradiated foods

  8. Energy-Recovery Linacs for Commercial Radioisotope Production

    International Nuclear Information System (INIS)

    Johnson, Rolland Paul

    2016-01-01

    Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently, a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities

  9. Energy-Recovery Linacs for Commercial Radioisotope Production

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Muplus, Inc., Newport News, VA (United States)

    2016-11-19

    Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently, a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities

  10. Radioisotope thermoelectric generator licensed hardware package and certification tests

    International Nuclear Information System (INIS)

    Goldmann, L.H.; Averette, H.S.

    1994-01-01

    This paper presents the Licensed Hardware package and the Certification Test portions of the Radioisotope Thermoelectric Generator Transportation System. This package has been designed to meet those portions of the Code of Federal Regulations (10 CFR 71) relating to ''Type B'' shipments of radioactive materials. The detailed information for the anticipated license is presented in the safety analysis report for packaging, which is now in process and undergoing necessary reviews. As part of the licensing process, a full-size Certification Test Article unit, which has modifications slightly different than the Licensed Hardware or production shipping units, is used for testing. Dimensional checks of the Certification Test Article were made at the manufacturing facility. Leak testing and drop testing were done at the 300 Area of the US Department of Energy's Hanford Site near Richland, Washington. The hardware includes independent double containments to prevent the environmental spread of 238 Pu, impact limiting devices to protect portions of the package from impacts, and thermal insulation to protect the seal areas from excess heat during accident conditions. The package also features electronic feed-throughs to monitor the Radioisotope Thermoelectric Generator's temperature inside the containment during the shipment cycle. This package is designed to safely dissipate the typical 4500 thermal watts produced in the largest Radioisotope Thermoelectric Generators. The package also contains provisions to ensure leak tightness when radioactive materials, such as a Radioisotope Thermoelectric Generator for the Cassini Mission, planned for 1997 by the National Aeronautics and Space Administration, are being prepared for shipment. These provisions include test ports used in conjunction with helium mass spectrometers to determine seal leakage rates of each containment during the assembly process

  11. Preparation of an annual report for a consolidated radioisotope licence

    International Nuclear Information System (INIS)

    1985-01-01

    A consolidated radioisotope licence is a single license issued by the Atomic Energy Control Board (AECB) to an institution having many users of radioactive materials. The licence is issued when the institution has fulfilled the requirements set by the AECB and has implemented policies and procedures which will ensure the maintenance of an effective radiation safety program. The consolidated licence is retained only if the results of AECB inspections are satisfactory -- or remedial action is taken promptly -- and if the institution reports regularly about the status of its radiation safety program. One aspect of this reporting procedure is an annual report. This guide describes the information that the AECB requires in the annual report. The guide applies primarily to universities and research institutions where a wide variety of radioisotope uses take place. The guide does not affect most other institutions or facilities, either because the nature and extent of their operations with radioactive materials do not lend themselves to consolidated licensing or because they are not licensed by the Radioisotopes and Transportation Division. (For example, this guide does not apply to reactors, to accelerators, or to waste management or uranium mining or refining facilities.) The information in the annual report should be specific to the consolidated radioisotope licence. Incidents, staff exposures, and waste associated with accelerators, research reactors, and waste management facilities should be excluded from this report unless they affected activities under the consolidated licence

  12. Safe Handling of Radioisotopes. Medical Addendum

    International Nuclear Information System (INIS)

    Hercik, F.; Jammet, H.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains information necessary to medical officers concerned with the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the medical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  13. Rhenium radioisotopes for therapeutic radiopharmaceutical development

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Pinkert, J.; Kropp, J.; Lin, W.Y.; Wang, S.Y.

    2001-01-01

    Rhenium-186 and rhenium-188 represent two important radioisotopes which are of interest for a variety of therapeutic applications in oncology, nuclear medicine and interventional cardiology. Rhenium-186 is directly produced in a nuclear reactor and the 90 hour half-life allows distribution to distant sites. The relatively low specific activity of rhenium-186 produced in most reactors, however, permits use of phosphonates, but limits use for labelled peptides and antibodies. Rhenium-188 has a much shorter 16.9 hour half-life which makes distribution from direct reactor production difficult. However, rhenium-188 can be obtained carrier-free from a tungsten-188/rhenium-188 generator, which has a long useful shelf-life of several months which is cost-effective, especially for developing regions. In this paper we discuss the issues associated with the production of rhenium-186- and rhenium-188 and the development and use of various radiopharmaceuticals and devices labelled with these radioisotopes for bone pain palliation, endoradiotherapy of tumours by selective catheterization and tumour therapy using radiolabelled peptides and antibodies, radionuclide synovectomy and the new field of vascular radiation therapy. (author)

  14. True-color 3D surface metrology for additive manufacturing using interference microscopy

    OpenAIRE

    DiSciacca, Jack; Gomez, Carlos; Thompson, Adam; Lawes, Simon; Leach, Richard; Colonna de Lega, Xavier; de Groot, Peter

    2017-01-01

    Coherence scanning interferometry (CSI) is widely used for surface topography characterisation. With the ability to measure both rough surfaces with the high slopes and optical finishes, CSI has made contibutions in fields from industrial machining to optical fabrication and polishing [1,2]. While the low coherence sources for CSI are typically broadband and suitable for color imaging, the metrology is usually performed without regards for the color information [3]. We present color surface t...

  15. Regulations concerning the radionuclides uses in France; Reglementation de l'utilisation des radioisotopes en France

    Energy Technology Data Exchange (ETDEWEB)

    Vergne, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Bugnard, L. [Institut national d' Hygiene (France)

    1955-07-01

    The progress in the uses of radioisotopes has been conditioned by increasing the number of trained workers and researchers and developing theoretical teaching in universities since 1950 in France as well as developing a national control of the distribution and uses of radioisotopes. With the large diffusion and development of radioisotopes uses and applications, new rules and regulations came to control the importation, exportation, transport and utilization of radioisotopes. In the first part, it described the different French laws since 1934 and their successive modifications which ruled on the production, manipulation and utilization of radioisotopes. An inter-ministerial committee was created in 1952 to advise and inform of all the questions related to the preparation, importation, exportation, possession and distribution of radioisotopes. The transport regulations are in constant evolution and has got to meet with international recommendations. It distinguished three different type of transport: road, river and railway transport, postal transport and finally air transport. All the different transports have their specific packaging, maximum transportable quantity, maximum material intensity and labelling requirements. The regulations about customs duties are specified as well as the administrative formalities for non natural radioisotopes importation. Since 1950, diseases caused by irradiation to natural or artificial radioactive materials are recognised as professional diseases and a table of the actual regulations is presented. (M.P.)

  16. Modeling human color categorization: Color discrimination and color memory

    OpenAIRE

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The experiments conducted prove the difference between color categorization by the cognitive processes color discrimination and color memory. In addition, they yield a Color Look-Up Table, which can improve c...

  17. Stirling Radioisotope Power System as an Alternative for NASAs Deep Space Missions

    Science.gov (United States)

    Shaltens, R. K.; Mason, L. S.; Schreiber, J. G.

    2001-01-01

    The NASA Glenn Research Center (GRC) and the Department of Energy (DOE) are developing a free-piston Stirling convertor for a Stirling Radioisotope Power System (SRPS) to provide on-board electric power for future NASA deep space missions. The SRPS currently being developed provides about 100 watts and reduces the amount of radioisotope fuel by a factor of four over conventional Radioisotope Thermoelectric Generators (RTG). The present SRPS design has a specific power of approximately 4 W/kg which is comparable to an RTG. GRC estimates for advanced versions of the SRPS with improved heat source integration, lightweight Stirling convertors, composite radiators, and chip-packaged controllers improves the specific mass to about 8 W/kg. Additional information is contained in the original extended abstract.

  18. Short-lived cyclotron-produced radioisotopes: Medi-Physics, Inc.'s commitment

    International Nuclear Information System (INIS)

    Kramer, H.H.

    1985-01-01

    Medi-Physics, Inc., is a major US supplier of short-lived cyclotron-produced radioisotopes for radiopharmaceuticals, as well as routinely producing and distributing the greatest number of 123 I radiopharmaceuticals. The present commercial production capacity for 123 I is more than ten times the theoretical need for existing procedures and is more than adequate for the research and development of new radiopharmaceuticals. However, production capacity is only one component of many that are required to supply a radioisotope for human use. These components are summarized in this paper

  19. Small radioisotope powered batteries

    International Nuclear Information System (INIS)

    Myatt, J.

    1975-06-01

    Various methods of converting the large amounts of energy stored in radioisotopes are described. These are based on:- (a) the Seebeck effect; (b) thermionic emission of electrons from a hot body; (c) the Stirling Cycle; and (d) radiovoltaic charge separation in 'p-n' junctions. Small generators in the range 0 to 100 W(e) developed using these effects are described and typical applications for each of these systems are given. These include data collection and transmission from remote sites, implantable medical devices, lighthouses, radio beacons, and space power supplies. (author)

  20. High temperature radioisotope capsule

    International Nuclear Information System (INIS)

    Bradshaw, G.B.

    1976-01-01

    A high temperature radioisotope capsule made up of three concentric cylinders, with the isotope fuel located within the innermost cylinder is described. The innermost cylinder has hemispherical ends and is constructed of a tantalum alloy. The intermediate cylinder is made of a molybdenum alloy and is capable of withstanding the pressure generated by the alpha particle decay of the fuel. The outer cylinder is made of a platinum alloy of high resistance to corrosion. A gas separates the innermost cylinder from the intermediate cylinder and the intermediate cylinder from the outer cylinder

  1. Decontamination of radioisotope production facility

    International Nuclear Information System (INIS)

    Daryoko, M.; Yatim, S.; Suseno, H.; Wiratmo, M.

    1998-01-01

    The strippable coating method use phosphoric glycerol and irradiated latex as supporting agents have been investigated. The investigation used some decontaminating agents: EDTA, citric acid, oxalic acid and potassium permanganate were combined with phosphoric glycerol supporting agent, then EDTA Na 2 , sodium citric, sodium oxalic and potassium permanganate were combined with irradiated latex supporting agent. The study was needed to obtain the representative operating data, will be implemented to decontamination the Hot Cell for radioisotope production. The experiment used 50x50x1 mm stainless steel samples and contaminated by Cs-137 about 1.1x10 -3 μCi/cm 2 . This samples according to inner cover of Hot Cell material, and Hot Cell activities. The decontamination factor results of the investigation were: phosphoric glycerol as supporting agent, about 20 (EDTA as decontaminating agent) to 47 (oxalic acid as decontaminating agent), and irradiated latex as supporting agent, about 11.5 (without decontamination agent) to 27 (KMnO 4 as decontaminating agent). All composition of the investigation have been obtained the good results, and can be implemented for decontamination of Hot Cell for radioisotope production. The irradiated latex could be recommended as supporting agent without decontaminating agent, because it is very easy to operate and very cheap cost. (author)

  2. The search for new radioisotopes; La recherche de nouveaux noyaux et de nouveaux elements

    Energy Technology Data Exchange (ETDEWEB)

    Bernas, M [Institut de Physique Nucleaire, IN2P3/CNRS, 91 - Orsay (France); Armbruster, P [GSI, Max-Planck-Str., Darmstadt (Germany)

    2000-07-01

    Phosphorus-30 was the first artificial radioisotope, it was produced by F. and I. Joliot-Curie in 1934, since then 2460 new nuclei have been discovered. This document reviews the radioisotopes known and the methods used to separate them. The authors describe the discovery of new radioisotopes such as Nickel-78 produced in the fission of high energy uranium ions impinging on a lead target (IPN-GSI collaboration) and the discovery of Nickel-48 by a team CENBG-Ganil. All this experience is useful for the processing of nuclear wastes by using transmutation. (A.C.)

  3. COMPARISON OF RETINAL PATHOLOGY VISUALIZATION IN MULTISPECTRAL SCANNING LASER IMAGING.

    Science.gov (United States)

    Meshi, Amit; Lin, Tiezhu; Dans, Kunny; Chen, Kevin C; Amador, Manuel; Hasenstab, Kyle; Muftuoglu, Ilkay Kilic; Nudleman, Eric; Chao, Daniel; Bartsch, Dirk-Uwe; Freeman, William R

    2018-03-16

    To compare retinal pathology visualization in multispectral scanning laser ophthalmoscope imaging between the Spectralis and Optos devices. This retrospective cross-sectional study included 42 eyes from 30 patients with age-related macular degeneration (19 eyes), diabetic retinopathy (10 eyes), and epiretinal membrane (13 eyes). All patients underwent retinal imaging with a color fundus camera (broad-spectrum white light), the Spectralis HRA-2 system (3-color monochromatic lasers), and the Optos P200 system (2-color monochromatic lasers). The Optos image was cropped to a similar size as the Spectralis image. Seven masked graders marked retinal pathologies in each image within a 5 × 5 grid that included the macula. The average area with detected retinal pathology in all eyes was larger in the Spectralis images compared with Optos images (32.4% larger, P < 0.0001), mainly because of better visualization of epiretinal membrane and retinal hemorrhage. The average detection rate of age-related macular degeneration and diabetic retinopathy pathologies was similar across the three modalities, whereas epiretinal membrane detection rate was significantly higher in the Spectralis images. Spectralis tricolor multispectral scanning laser ophthalmoscope imaging had higher rate of pathology detection primarily because of better epiretinal membrane and retinal hemorrhage visualization compared with Optos bicolor multispectral scanning laser ophthalmoscope imaging.

  4. Advanced radioisotope power source options for Pluto Express

    International Nuclear Information System (INIS)

    Underwood, M.L.

    1995-01-01

    In the drive to reduce mass and cost, Pluto Express is investigating using an advanced power conversion technology in a small Radioisotope Power Source (RPS) to deliver the required mission power of 74 W(electric) at end of mission. Until this year the baseline power source under consideration has been a Radioisotope Thermoelectric Generator (RTG). This RTG would be a scaled down GPHS RTG with an inventory of 6 General Purpose Heat Sources (GPHS) and a mass of 17.8 kg. High efficiency, advanced technology conversion options are being examined to lower the power source mass and to reduce the amount of radioisotope needed. Three technologies are being considered as the advanced converter technology: the Alkali Metal Thermal-to-Electric Converter (AMTEC), Thermophotovoltaic (TPV) converters, and Stirling Engines. Conceptual designs for each of these options have been prepared. Each converter would require only 2 GPHSs to provide the mission power and would have a mass of 6.1, 7.2, and 12.4 kg for AMTEC, TPV, and Stirling Engines respectively. This paper reviews the status of each technology and the projected performance of an advanced RPS based on each technology. Based on the projected performance and spacecraft integration issues, Pluto Express would prefer to use the AMTEC based RPS. However, in addition to technical performance, selection of a power technology will be based on many other factors

  5. A survey of images of a phantom produced by radioisotope scanners and cameras

    International Nuclear Information System (INIS)

    1976-01-01

    A working party of the Department of Health and Social Security (DHSS) concerned with the assessment of performance of radioisotope-imaging equipment designed a test pattern called the Williams Phantom. The criteria and design are discussed. It consists of four 'cold' and four 'hot' areas. One Williams Phantom was sent to each radioisotope-imaging centre in Great Britain: the images produced were sent to the DHSS. The variation in image quality was large. A comprehensive sample of the images of the phantom produced on a variety of radioisotope scanners and γ cameras is presented to illustrate a number of general observations made by the working party. (U.K.)

  6. The risk of internal contamination of workers employed in radioisotope laboratories in Poland

    International Nuclear Information System (INIS)

    Adamiak-Ziemba, J.; Domanski, T.; Doniec, J.

    1981-01-01

    It was established that in Poland 247 radioisotope laboratories use open radiation sources. These laboratories have not yet been covered by the internal system of control of inner contamination. The number of workers having contact with radioisotopes amounts to 1987. Frequently this is work in contact with several radioisotopes (from 1 to 17). Most workers are exposed to tritium (over 500 workers), 14 C (over 500), 125 I and 131 I, 32 P, 51 Cr, 99mTc (over 100), isotopes belonging to radiotoxicity groups 2, 3 and 4. In the radiotoxicity group 1 the most workers were exposed to 226 Ra (52). (author)

  7. Reflections on the juridical implications of the medical use of radiations and radioisotope

    International Nuclear Information System (INIS)

    Campos, Ana Celia P.P.; Cuperschmid, Ethel Mizrahy; Campos, Tarcisio P. Ribeiro de

    2007-01-01

    The pacific use of radiation and radioisotopes for the society presents radiological risks, due its capacity to produce damage to environmental and human being, contrasting with its high economic and social benefits. In the face of the risk, juridical system leans over to reach the required regulations that implies in the balance between human and environmental security and the expected improvements of the medical nuclear techniques. The Brazilian Constitution of 1988 tries to provide the normalization for the application of the nuclear energy and its radioisotopes. However, target as a strategically technology and due to its expansion, its regulations still deserves analyses and reflections. The present paper starts from the Constitution presenting the references about the theme and analyzing it. It is addressed the principle of the objective civil responsibility making analyses on the use of radiations and radioisotope on the medicine. It addresses the role of federal autonomy related to the 'MCT - Ministerio de Ciencia e Tecnologia' with its accumulative functions in society, such as scientific and technologic development, education, and its own focalization. The recent opening of the monopoly for the production of radioisotopes for very short half-lives is also discussed. It makes a comparison between juridical aspects of Brazil with international system. The present article contributes to open same topics of discussions on the Brazilian juridical aspects involving radiations and radioisotopes application on medicine. (author)

  8. Reflections on the juridical implications of the medical use of radiations and radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Ana Celia P.P. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Direito]. E-mails: anaceu2000@yahoo.com.br; Cuperschmid, Ethel Mizrahy [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Centro de Memoria da Medicina - CEMMOR]. E-mail: ethel.mizrahy@yahoo.com; Campos, Tarcisio P. Ribeiro de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg.br

    2007-07-01

    The pacific use of radiation and radioisotopes for the society presents radiological risks, due its capacity to produce damage to environmental and human being, contrasting with its high economic and social benefits. In the face of the risk, juridical system leans over to reach the required regulations that implies in the balance between human and environmental security and the expected improvements of the medical nuclear techniques. The Brazilian Constitution of 1988 tries to provide the normalization for the application of the nuclear energy and its radioisotopes. However, target as a strategically technology and due to its expansion, its regulations still deserves analyses and reflections. The present paper starts from the Constitution presenting the references about the theme and analyzing it. It is addressed the principle of the objective civil responsibility making analyses on the use of radiations and radioisotope on the medicine. It addresses the role of federal autonomy related to the 'MCT - Ministerio de Ciencia e Tecnologia' with its accumulative functions in society, such as scientific and technologic development, education, and its own focalization. The recent opening of the monopoly for the production of radioisotopes for very short half-lives is also discussed. It makes a comparison between juridical aspects of Brazil with international system. The present article contributes to open same topics of discussions on the Brazilian juridical aspects involving radiations and radioisotopes application on medicine. (author)

  9. Survey of literature on dispersion ratio and collection ratio of radioisotopes in animal study using radioisotopes

    International Nuclear Information System (INIS)

    Tozuka, Zenzaburo; Doi, Masahiro; Miyazawa, Eiji; Kawakami, Takeo

    1998-01-01

    A survey of literature in the title was performed to know the actual status of the dispersion from excretion and expiration studies of radioisotopes since, at present, the probable dispersion ratio is assumed to be 100% in calculation for legally permitted use of radioisotopes which conceivably being far from the real status and being incompatible with the guideline for pharmacokinetic studies requiring the recovery of >95% of dosed radioactivity in balance study. There are two interpretations for the dispersion; it is the expiration ratio and it is the fraction unrecovered. Survey was done on 11 Japanese and foreign journals in 1985-1996 publishing most of pharmacokinetic studies and on 650 compounds in 358 facilities with 1,975 experiments in total. In those experiments, the total recovery of radioactivity was 95% in average, unrecovered fraction, 5% and expiration ratio, 2%. As for unclide, 14 C, 3 H, 125 I and 35 S were surveyed since they occupied 99.4% of the experiments and their dispersion was <5%. Rats were used in 70% of the experiments and the dispersion in all animal experiments was about 5%. Administration route was regardless of the dispersion. (K.H.)

  10. Production of radioisotopes by 1.5 m cyclotron and their utilization

    International Nuclear Information System (INIS)

    Niu Fang

    1987-01-01

    Radioisotopes characterized by nuclear property and uses can be produced on the accelerator, especially those playing an important role in scientific researches and biomedical uses. The status of Radioisotopes produced by 1.5 m cyclotron and their applications in our institute are summarized in this paper. The details of preparation and the results of use for radioactive sources, radiochemicals, radiopharmaceuticals of 57 Co, 109 Cd, 68 Ge- 68 Ga, and 167 Tm are given respectively. (author)

  11. Research with radioisotopes in clinical and laboratory medicine: a bibliographic review

    International Nuclear Information System (INIS)

    Metz, J.; Van der Walt, L.A.; Malan, J.M.

    1985-01-01

    This bibliography is restricted mainly to AEC-supported projects which are considered to amply reflect the widespread use of radioisotopes in clinical and laboratory medicine in South Africa and which describe research with radioisotopes of some direct relevance to diagnostic-clinical or laboratory medicine, or both, but excluding therapy with isotopes. General information is given in this review on oncology, endocrinology, metabolism and nutrition, haematology, neurology, angiocardiology, pulmonology, gastroenterology, gynaecology and obstetrics, nephrology, immunology and transplantation, microbiology and parasitology

  12. Color-coded volume rendering for three-dimensional reconstructions of CT data

    International Nuclear Information System (INIS)

    Rieker, O.; Mildenberger, P.; Thelen, M.

    1999-01-01

    Purpose: To evaluate a technique of colored three-dimensional reconstructions without segmentation. Material and methods: Color-coded volume rendered images were reconstructed from the volume data of 25 thoracic, abdominal, musculoskeletal, and vascular helical CT scans using commercial software. The CT volume rendered voxels were encoded with color in the following manner. Opacity, hue, lightness, and chroma were assigned to each of four classes defined by CT number. Color-coded reconstructions were compared to the corresponding grey-scale coded reconstructions. Results: Color-coded volume rendering enabled realistic visualization of pathologic findings when there was sufficient difference in CT density. Segmentation was necessary in some cases to demonstrate small details in a complex volume. Conclusion: Color-coded volume rendering allowed lifelike visualisation of CT volumes without the need of segmentation in most cases. (orig.) [de

  13. The use of radioisotopes in the developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1963-04-15

    Some of the more important isotope applications, especially those which are or can be profitably introduced in the developing countries, are reviewed. The use of radioisotopes in industry, medicine, agriculture, and hydrology is discussed

  14. Production of radioisotopes within a plasma focus device

    International Nuclear Information System (INIS)

    Angeli, E.; Tartari, A.; Frignani, M.; Molinari, V.; Mostacci, D.; Rocchi, F.; Sumini, M. . E-mail address of corresponding author: domiziano.mostacci@mail.ing.unibo.it

    2005-01-01

    In recent years, research conducted in the US and in Italy has demonstrated production of radioisotopes in Plasma Focus (PF) devices, and particularly, on what could be termed 'endogenous' production, to wit, production within the plasma itself, as opposed to irradiation of targets. This technique relies on the formation of localized small plasma zones characterized by very high densities and fairly high temperatures. The conditions prevailing in these zones lead to high nuclear reaction rates, as pointed out in previous work by several authors. Further investigation of the cross sections involved has proven necessary to model the phenomena involved. In this paper, the present status of research in this field is reviewed, both with regards to cross section models and to experimental production of radioisotopes. Possible outcomes and further development are discussed. (author)

  15. Recovery of hafnium radioisotopes from a proton irradiated tantalum target

    International Nuclear Information System (INIS)

    Taylor, W.A.; Garcia, J.G.; Hamilton, V.T.; Heaton, R.C.; Jamriska, D.J.; Ott, M.A.; Philips, D.R.; Radzinski, S.D.

    1998-01-01

    The 178m2 Hf nucleus, with its long half-life (31 y) and high-spin isomeric state (16 + ) is desired for new and exotic nuclear physics studies. The Los Alamos Radioisotope Program irradiated a kilogram of natural tantalum at the Los Alamos Meson Physics Facility in early 1981. After fifteen years of decay, this target was ideal for the recovery of 178m2 Hf. There was more than a millicurie of 178m2 Hf produced during this irradiation and there has been a sufficient period of time for most of the other hafnium radioisotopes to decayed away. Traditionally, separation techniques for recovering hafnium isotopes from tantalum targets employ solvent extractions with reagents that are considered hazardous. These techniques are no longer condoned because they generate a mixed-waste (radioactive and hazardous components) that can not be treated for disposal. In this paper we describe a new and unique procedure for the recovery of hafnium radioisotopes from a highly radioactive, proton irradiated, tantalum target using reagents that do not contribute a hazardous waste component. (author)

  16. A summary of waste disposal operator and office abolition of the Radioisotope Center in the University of Tokyo

    International Nuclear Information System (INIS)

    Higaki, Shogo; Kosaka, Naoki; Nogawa, Norio

    2014-01-01

    Radioisotope center in the University of Tokyo had approval of waste disposal operator only in the universities of Japan since 1983. However, the radioisotope center abolished the waste disposal office in December 2013. In this paper, we summarize the history of the waste disposal operator in the radioisotope center, and report the procedure of office abolition under the Japanese law and regulations concerning prevention from radiation hazards due to radio-isotopes, etc. revised after April 2012. (author)

  17. Study on application of radiation and radioisotopes -Development of the radioisotope production facilities for the HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Bok; Woo, Jong Sub; Kang, Byung Woi; Baek, Sam Tae; Jeong, Un Soo; Park, Yong Chul; Jeon, Young Keon; Chang, Chun Ik; Lee, Bong Jae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-08-01

    Development and construction of the lead hot cell for radioisotope production and related facility. 1. Fabrication and installation of the lead H/C system. 2. Development and installation of the hydraulic transfer system. 3. Development of the radiation monitoring system. 4. Fabrication and installation of the fire extinguishing system in the H/C. 5. Fabrication and installation of the fume hood. 4 tabs.,10 figs. (Author).

  18. Radioisotope electric propulsion for robotic science missions to near-interstellar space

    International Nuclear Information System (INIS)

    Noble, R.J.

    1994-10-01

    The use of radioisotope electric propulsion for sending small robotic probes on fast science missions several hundred astronomical units (AU) from the Sun is investigated. Such missions would address a large variety of solar, interstellar, galactic and cosmological science themes from unique vantage points at 100 to 600 AU, including parallax distance measurements for the entire Milky Way Galaxy, sampling of the interstellar medium and imaging of cosmological objects at the gravitational lens foci of the Sun (≥ 550 AU). Radioisotope electric propulsion (REP) systems are low-thrust, ion propulsion units based on multi-hundred watt, radioisotope electric generators and ion thrusters. In a previous work, the flight times for rendezvous missions to the outer planets (< 30 AU) using REP were found to be less than fifteen years. However fast prestellar missions to several hundred AU are not possible unless the probe's energy can be substantially increased in the inner Solar System so as to boost the final hyperbolic excess velocity. In this paper an economical hybrid propulsion scheme combining chemical propulsion and gravity assist in the inner Solar System and radioisotope electric propulsion in the outer Solar System is studied which enables fast prestellar missions. Total hyperbolic excess velocities of 15 AU/year and flight times to 550 AU of about 40 years are possible using REP technology that may be available in the next decade

  19. Clouds, airplanes, trucks and people: carrying radioisotopes to and across Mexico.

    Science.gov (United States)

    Mateos, Gisela; Suárez-Díaz, Edna

    2015-01-01

    The aim of this paper is to describe the early stages of Mexican nuclearization that took place in contact with radioisotopes. This history requires a multilayered narrative with an emphasis in North-South asymmetric relations, and in the value of education and training in the creation of international asymmetrical networks. Radioisotopes were involved in exchanges with the United States since the late 1940s, but also with Canada. We also describe the context of implementation of Eisenhower's Atoms for Peace initiative in Mexico that opened the door to training programs at both the Comisión Nacional de Energía Nuclear and the Universidad Nacional Autónoma de México. Radioisotopes became the best example of the peaceful applications of atomic energy, and as such they fitted the Mexican nuclearization process that was and still is defined by its commitment to pacifism. In 1955 Mexico became one of the 16 members of the atomic fallout network established by the United Nations. As part of this network, the first generation of Mexican (women) radio-chemists was trained. By the end of the 1960s, radioisotopes and biological markers were being produced in a research reactor, prepared and distributed by the CNEN within Mexico. We end up this paper with a brief reflection on North-South nuclear exchanges and the particularities of the Mexican case.

  20. Comparison between Radioisotopic and Non-radioisotopic Polymerase Chain Reaction-Single Strand Conformation Polymorphism (PCR-SSCP) Procedures in the Detection of Mutations at the rpoB Gene Associated with Rifampicin Resistance in Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Lee, H.; Bang, H.E.; Johnson, R.; Jordaan, A.M.; Victor, T.C. . E-mail : tv@sun.ac.za; Dar, L.; Khan, B.K.; Cho, S.N. . E-mail : raycho@yonsei.ac.kr

    2006-01-01

    Rapid and sensitive detection of mutations at the rpoB gene of Mycobacterium tuberculosis would be of great importance for proper management of tuberculosis (TB) patients and control of multi-drug resistant TB. Polymerase chain reaction-single strand conformation polymorphism (PCR-SSCP) using both radioisotopic and non-radioisotopic methods have been widely used for detecting such mutations. However, the silver staining method, which is the most frequently employed in PCR-SSCP, has been reported to be producing results of varying sensitivity. Radioisotope-based methods have shown greater sensitivity in detecting the rpoB mutations than the silver staining method. The primary objective of this study was therefore to compare the radioisotopic method with the silver staining method detection of mutations of rpoB gene by PCR-SSCP in the same laboratory. Purified DNAs from M. tuberculosis H37Rv were serially diluted and used for PCR amplification with and without radionuclides. The PCR products were then detected by silver staining and autoradiography methods. In addition, clinical isolates were analyzed by PCR-SSCP. The radioisotopic method showed about four-fold increase in the detection of PCR products over ethidium bromide staining in agarose gel. When compared with silver staining, the radioisotopic method gave a sensitivity of more than 10-fold in detecting PCR products and about 8-fold in PCR-SSCP. Radioisotope-based detection methods provided a clearer resolution in PCR-SSCP than the silver staining method when applied to clinical isolates of M. tuberculosis. Radioisotope-based detection method was shown to be more sensitive than non-isotope-based method in detecting PCR products and mutations at the rpoB gene of M. tuberculosis by PCR-SSCP. It may be noted that mutations in the rpoB gene as a marker have significant clinical importance because of the increasing number of MDR-TB cases in the world. It is especially relevant to MDR and Extreme Drug Resistance TB

  1. Discrete radioisotopic relays of a cyclic action

    International Nuclear Information System (INIS)

    Klempner, K.S.; Vasil'ev, A.G.

    1975-01-01

    A functional diagram of discrete radioisotopic relay equipment (RRP) with cyclic action was examined. An analysis of its rapid action and reliability under stationary conditions and transition regimes is presented. A structural diagram of radioisotopic relay equipment shows three radiation detectors, a pulse standardizer, an integrator and a power amplifier with a threshold cut-off device. It was established that the basic properties of the RRP - rapid action and reliability - are determined entirely by the counting rate of the average frequency of pulses from the radiation detector, n 0 and n 1 , in the 0 and 1 states (absence of current in the electromagnetic relay winding and activation of the winding of the output relay), capacities N 1 and N 2 of the dual counters, and the frequency of the transition threshold, f, of the generator. Formulas are presented which allow making engineering calculations for determining the optimum RRP parameters. High speed and reliability are shown, which are determined by the production purposes of the relay

  2. Real time recording system of radioisotopes by local area network (LAN) computer system and user input processing

    International Nuclear Information System (INIS)

    Shinohara, Kunio; Ito, Atsushi; Kawaguchi, Hajime; Yanase, Makoto; Uno, Kiyoshi.

    1991-01-01

    A computer-assisted real time recording system was developed for management of radioisotopes. The system composed of two personal computers forming LAN, identification-card (ID-card) reader, and electricity-operating door-lock. One computer is operated by radiation safety staffs and stores the records of radioisotopes. The users of radioisotopes are registered in this computer. Another computer is installed in front of the storage room for radioisotopes. This computer is ready for operation by a registered ID-card and is input data by the user. After the completion of data input, the door to the storage room is unlocked. The present system enables us the following merits: Radiation safety staffs can easily keep up with the present states of radioisotopes in the storage room and save much labor. Radioactivity is always corrected. The upper limit of radioactivities in use per day is automatically checked and users are regulated when they input the amounts to be used. Users can obtain storage records of radioisotopes any time. In addition, the system is applicable to facilities which have more than two storage rooms. (author)

  3. Industrial applications of radioisotopes: techniques and procedures of (NTIS) Nuclear Techniques Industrial Service

    International Nuclear Information System (INIS)

    Smith, S.W.; Kruger, J.

    1985-06-01

    Radioisotope handling procedures followed by personnel of the Nuclear Techniques Industrial Service (NTIS) during the conduction of investigations in industry are described. Possible radiological implications as a result of the various measuring techniques and different types of plants are discussed. Conditions under which permanent authorization has been granted for the use of radioisotopes are mentioned

  4. Prospective production of radioisotopes and radiopharmaceuticals in divisions of IPPE

    International Nuclear Information System (INIS)

    Terentyev, G.O.

    2001-01-01

    The first reason to commence the work on production of radioisotope production in IPPE, was the requirement of Russia medicine for original generators of technetium. The essential extension of their production in conditions of Moscow city has met the declaiming of the Moscow urban authorities. The important moment was that, in IPPE were objective possibilities to deployment the production of radioisotope production. Nowadays, nomenclature of the radioisotopes which have been produced in IPPE, constitutes 29 positions. The profile of production of radioisotope production was generated also. Restricted possibilities of the ray base, from one side, and the needs(requirement) of domestic medicine with other, in main have spotted this profile. The raw isotopes constitute a minority - on sales volumes ∼ 20 % (in main abroad), the defining part is constituted the form ready for the use by ∼ 80 % (in main in Russia). All 'know-how' is conditionally possible to divide into 3 categories: Base. It is technologies provided with an operating production sector, guaranteeing stable on quality production having a rather wide seller's market; Perspective. It is those technologies, in which the main stages of RESEARCH and DEVELOPMENT are fulfilled with positive result, but the working sites yet are not generated, and on the market are delivered only some samples of production. Are guessed RESEARCH AND DEVELOPMENT on perfecting the technology; Preparative. The technology, on which there are no regular orders, is not required of an individual working site. Sometimes it is rather precision operations, bound with usage of unique raw material, with a very stiff price of production. (authors)

  5. Multispectral colour analysis for quantitative evaluation of pseudoisochromatic color deficiency tests

    Science.gov (United States)

    Ozolinsh, Maris; Fomins, Sergejs

    2010-11-01

    Multispectral color analysis was used for spectral scanning of Ishihara and Rabkin color deficiency test book images. It was done using tunable liquid-crystal LC filters built in the Nuance II analyzer. Multispectral analysis keeps both, information on spatial content of tests and on spectral content. Images were taken in the range of 420-720nm with a 10nm step. We calculated retina neural activity charts taking into account cone sensitivity functions, and processed charts in order to find the visibility of latent symbols in color deficiency plates using cross-correlation technique. In such way the quantitative measure is found for each of diagnostics plate for three different color deficiency carrier types - protanopes, deutanopes and tritanopes. Multispectral color analysis allows to determine the CIE xyz color coordinates of pseudoisochromatic plate design elements and to perform statistical analysis of these data to compare the color quality of available color deficiency test books.

  6. Fuel selection for radioisotope thermoelectric generators

    International Nuclear Information System (INIS)

    Menezes, A.

    1988-06-01

    The availability of Radioisotope Thermoeletric Generator fuels is evaluated based on the amount of fuel discharged from selected power reactors. In general, the best alternatives are either to use Plutonium-238 produced by irradiation of Neptunium-237 generated in typical thermal reactors or to use Curium-244 directly separated from the discharged fuels of fast or thermal reactors. (author) [pt

  7. Radioisotope techniques used in breast cancer

    International Nuclear Information System (INIS)

    Au-Yong Ting Kun

    2001-01-01

    Breast cancer is one of the commonest cancer in women. Treatment and prognosis of breast cancer depend very much on accurate diagnosis, staging and follow-up of patients. Recently, there are several radioisotope techniques developed and have great impact on management of breast cancer. These include scintimammography, sentinel lymph node detection and positron emission tomography. This article is to review these important techniques

  8. Investigation of Insulation Materials for Future Radioisotope Power Systems

    Science.gov (United States)

    Cornell, Peggy A.; Hurwitz, Frances I.; Ellis, David L.; Schmitz, Paul C.

    2013-01-01

    NASA's Radioisotope Power Systems (RPS) Technology Advancement Project is developing next generation high-temperature insulation materials that directly benefit thermal management and improve performance of RPS for future science missions. Preliminary studies on the use of multilayer insulation (MLI) for Stirling convertors used on the Advanced Stirling Radioisotope Generator (ASRG) have shown the potential benefits of MLI for space vacuum applications in reducing generator size and increasing specific power (W/kg) as compared to the baseline Microtherm HT (Microtherm, Inc.) insulation. Further studies are currently being conducted at NASA Glenn Research Center on candidate MLI foils and aerogel composite spacers. This paper presents the method of testing of foils and spacers and experimental results to date.

  9. Radioisotope techniques for process optimisation and control in the offshore oil and gas industries

    International Nuclear Information System (INIS)

    Charlton, J.S.

    2002-01-01

    For over fifty years, radioisotope technology has been used by the oil industry to solve problems and to help optimise process operations. The widespread development of offshore oil and gas fields has brought, and continues to bring, new challenges and, in response, new or modified applications of radioisotope technology have been introduced. This paper presents case studies, which illustrate the use of radioisotopes, both in the sub-sea environment and on the offshore production platforms. On the platform, radioisotope techniques applied singly or in combination, have been applied to the performance assessment of oil/gas separation and gas dehydration units. Novel nucleonic instrumentation has been developed for the control of three-phase separators. Sub-sea, radioactive tracers and/or sealed sources have been used to investigate the integrity of submerged structures and to troubleshoot pipeline problems. The continuing expansion in the use of this technology stems from industry increasing awareness of its versatility and from the fact that the benefits it confers can be obtained at a relatively modest cost. Examples of economic benefit described in the paper are associated with production enhancements derived from the ability of radioisotope technology to measure performance and diagnose problems on line, without disrupting process operations in any way. (Author)

  10. Coastal Zone Color Scanner

    Science.gov (United States)

    Johnson, B.

    1988-01-01

    The Coastal Zone Color Scanner (CZCS) spacecraft ocean color instrument is capable of measuring and mapping global ocean surface chlorophyll concentration. It is a scanning radiometer with multiband capability. With new electronics and some mechanical, and optical re-work, it probably can be made flight worthy. Some additional components of a second flight model are also available. An engineering study and further tests are necessary to determine exactly what effort is required to properly prepare the instrument for spaceflight and the nature of interfaces to prospective spacecraft. The CZCS provides operational instrument capability for monitoring of ocean productivity and currents. It could be a simple, low cost alternative to developing new instruments for ocean color imaging. Researchers have determined that with global ocean color data they can: specify quantitatively the role of oceans in the global carbon cycle and other major biogeochemical cycles; determine the magnitude and variability of annual primary production by marine phytoplankton on a global scale; understand the fate of fluvial nutrients and their possible affect on carbon budgets; elucidate the coupling mechanism between upwelling and large scale patterns in ocean basins; answer questions concerning the large scale distribution and timing of spring blooms in the global ocean; acquire a better understanding of the processes associated with mixing along the edge of eddies, coastal currents, western boundary currents, etc., and acquire global data on marine optical properties.

  11. RisoeScan 1.0 - User manual and toolset for retrospective validation

    Energy Technology Data Exchange (ETDEWEB)

    Helt-Hansen, J

    2004-12-01

    The RisoeScan software is used for dose measurements with radiochromic films that color visibly. This report consists of two documents for use with the RisoeScan software. The User Manual tells how to use the program and the Toolset for Retrospective Validation describes how to perform a retrospective validation of the software. (au)

  12. Radioisotope Sources of Electric Power

    Science.gov (United States)

    1973-09-20

    u) watt/cm-3 O) specific activity f) curia/watt (curie/a) a) half-life c) specific power output h) years (capacity) 1) days d) watt/p Polonium - 210 ...AD/A-001 210 RADIOISOTOPE SOURCES OF ELECTRIC POWER G. M. Fradkin, et al Army Foreign Science and Technology Center Charlottesville, Virginia 20...narticularlv for nurninn and irocess~ino of wastg.Sheatinc food , conversion of liruld oxtoner to des, and also for removal of imnurities and reula:tion

  13. Electron Beam Scanning in Industrial Applications

    Science.gov (United States)

    Jongen, Yves; Herer, Arnold

    1996-05-01

    Scanned electron beams are used within many industries for applications such as sterilization of medical disposables, crosslinking of wire and cables insulating jackets, polymerization and degradation of resins and biomaterials, modification of semiconductors, coloration of gemstones and glasses, removal of oxides from coal plant flue gasses, and the curing of advanced composites and other molded forms. X-rays generated from scanned electron beams make yet other applications, such as food irradiation, viable. Typical accelerators for these applications range in beam energy from 0.5MeV to 10 MeV, with beam powers between 5 to 500kW and scanning widths between 20 and 300 cm. Since precise control of dose delivery is required in many of these applications, the integration of beam characteristics, product conveyance, and beam scanning mechanisms must be well understood and optimized. Fundamental issues and some case examples are presented.

  14. Present situation of the production and use of radioisotopes in France

    International Nuclear Information System (INIS)

    Fisher, Charlie

    1974-01-01

    As the sole large scale producer of radioisotopes in France, the Commissariat a l'Energie Atomique is keeping up pace with all developments in medical, biological and industrial areas. This production will reach the turnover close to 40 million F in 1973. About 65% of the products will go to medical market, 10% to biology and the remaining 25% to industry. As medical products, many radioisotopes are used for in-vivo diagnosis, while radioimmunology techniques are well known in in-vitro diagnosis. There has been very few noticeable development in therapeutics. Also there is steadily increasing demand for 14 C, 3 H and 13 C-labelled materials which are used to study metabolism of natural substances and drugs. The industrial utilization of radioisotopes in France is developed by CEA as well as several industrial companies. Trend must be analyzed for the different segments of the market which includes tracer utilization, instrumentation, large source technology such as sterilization of medical supplies, activation analysis and isotopic generators. (Wakatsuki, Y.)

  15. Radioisotopes in the Physical Sciences and Industry. Proceedings of the Conference on the Use of Radioisotopes in the Physical Sciences and Industry. V. III

    International Nuclear Information System (INIS)

    1962-01-01

    The Conference on the Use of Radioisotopes in the Physical Sciences and Industry, which took place in Copenhagen in September 1960, was the latest of a series of isotope conferences which began in 1951 at Oxford and continued with those held in 1954, again at Oxford, and in 1957 in Paris. The development of the uses of radioisotopes had been so rapid and many-sided that this Copenhagen Conference, organized by the IAEA with the co-operation of UNESCO, had to be restricted to applications in the physical sciences and industry. Applications of radioisotopes in animal biology and the medical sciences were discussed at the Conference held in Mexico City in November 1961. Even so, more than 500 scientists attended the Conference in Copenhagen and over 140 contributions were presented and discussed by this international gathering. Many more papers of great interest were submitted but could not be fitted into the programme. The proceedings of this Conference demonstrate the advances which had taken place since the earlier meetings in Oxford and Paris. It is hoped that this publication will contribute towards the stimulation of further research in the application of radioactive techniques.

  16. Development of radioisotope preparation and application technology

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hyon Soo; Park, K. B.; Bang, H. S. [and others

    2000-04-01

    The purpose of this project is to develop RI production technology utility 'HANARO' and to construct a sound infra-structure for mass production and supply to domestic users. The developed contents and results are as follows: two types of rig for irradiation in reactor core were designed and manufactured. The safety of OR rig during irradiation was identified through various test and it is used for RI production. The prepared IR rig will be used to performance tests for safety. We prepared two welders and welding jigs for production of sealed sources, and equipments for quality control of the welded materials. Production processes and apparatus Cr-51, P-32, I-125 and Sr-89, were developed. Developed results would be used for routine production and supply of radioisotopes. The automatic Tc-99m extraction apparatus was supplied to Libya under IAEA support. For approval on special form radioactive material of the developed Ir-192 source assembly and projector documents were prepared and submitted to MOST. The high dose rate Ir-192 source(diameter 1.1 mm, length 5.2 mm) for RALS and the laser welding system for its fabrication were developed. Production technologies of Ir-192 sources for destructive test and medical therapy were transferred to private company for commercial supply. The chemical immobilization method based on the self-assemble monolayer of {omega}-functionalized thiol and the sensing scheme based on the beta-emitter labeling method were developed for the fabrication radioimmuno-sensors. Results of this study will be applied to mass production of radioisotopes 'HANARO' and are to contribute the advance of domestic medicine and industry related to radioisotopes.

  17. Development of radioisotope preparation and application technology

    International Nuclear Information System (INIS)

    Han, Hyon Soo; Park, K. B.; Bang, H. S. and others

    2000-04-01

    The purpose of this project is to develop RI production technology utility 'HANARO' and to construct a sound infra-structure for mass production and supply to domestic users. The developed contents and results are as follows: two types of rig for irradiation in reactor core were designed and manufactured. The safety of OR rig during irradiation was identified through various test and it is used for RI production. The prepared IR rig will be used to performance tests for safety. We prepared two welders and welding jigs for production of sealed sources, and equipments for quality control of the welded materials. Production processes and apparatus Cr-51, P-32, I-125 and Sr-89, were developed. Developed results would be used for routine production and supply of radioisotopes. The automatic Tc-99m extraction apparatus was supplied to Libya under IAEA support. For approval on special form radioactive material of the developed Ir-192 source assembly and projector documents were prepared and submitted to MOST. The high dose rate Ir-192 source(diameter 1.1 mm, length 5.2 mm) for RALS and the laser welding system for its fabrication were developed. Production technologies of Ir-192 sources for destructive test and medical therapy were transferred to private company for commercial supply. The chemical immobilization method based on the self-assemble monolayer of ω-functionalized thiol and the sensing scheme based on the beta-emitter labeling method were developed for the fabrication radioimmuno-sensors. Results of this study will be applied to mass production of radioisotopes 'HANARO' and are to contribute the advance of domestic medicine and industry related to radioisotopes

  18. Administration of radioisotope production

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1964-01-15

    Current developments in atomic energy, and the administrative problems to which they give rise, were surveyed in a seminar on 'Atomic Energy for Atomic Energy Administrators' held at IAEA headquarters from 30 September to 4 October 1963. The ground covered included protection against radiation, isotopes and radiation sources, research reactors, nuclear power, legal matters, technical and scientific administration, the role of the universities, and the Agency's part in assistance to developing countries. The possibilities and limitations of radioisotope production from research reactors were discussed by Dr. G. B. Cook, of the Division of Research and Laboratories, IAEA in this paper.

  19. Administration of radioisotope production

    International Nuclear Information System (INIS)

    1964-01-01

    Current developments in atomic energy, and the administrative problems to which they give rise, were surveyed in a seminar on 'Atomic Energy for Atomic Energy Administrators' held at IAEA headquarters from 30 September to 4 October 1963. The ground covered included protection against radiation, isotopes and radiation sources, research reactors, nuclear power, legal matters, technical and scientific administration, the role of the universities, and the Agency's part in assistance to developing countries. The possibilities and limitations of radioisotope production from research reactors were discussed by Dr. G. B. Cook, of the Division of Research and Laboratories, IAEA in this paper.

  20. Cardiovascular: radioisotopic angiocardiography

    International Nuclear Information System (INIS)

    Kriss, J.P.

    1975-01-01

    Radioisotopic angiocardiography, performed after the intravenous injection of 99 /sup m/Tc-labeled pertechnetate or albumin, is a simple, rapid, and safe procedure which permits identification and physiologic assessment of a wide variety of congenital and acquired cardiovascular lesions in infants and children. These include atrial and ventricular septal defect, tetralogy of Fallot, pulmonic stenosis, aortopulmonary window, transposition of the great vessels, valvular stenosis and/or insufficiency, myocardial lesions, and lesions of the great vessels. The simplicity of the procedure lends itself to repeated measurements to assess the effects of therapy or to follow the course of the disease. A wide spectrum of congenital and acquired cardiovascular diseases have been studied which have particular application to the pediatric age group. (auth)

  1. Generation of radioisotopes

    International Nuclear Information System (INIS)

    Panek-Finda, H.

    1984-01-01

    A method of producing radioisotopes for radiopharmaceutical applications is claimed. A physiological solution is used to elute a radioactive daughter isotope from a fission-produced parent isotope adsorbed on an adsorbent. The eluate containing the daughter isotope is purified with a cation-exchange material. In separate claims: the parent isotope is molybdenum-99; aluminium oxide which contains fully or partly hydrated manganese dioxide is used as the adsorbent for the parent isotope; a resin is used as the cation-exchange material; a strongly acid cation-exchange resin which has been neutralized is used as a resin; and a strongly acid cation-exchange resin which has been converted into the Na + , K + or NH 4 + form is used as a resin; an isotope generator system is also claimed

  2. RisøScan 1.0 - User manual and toolset for retrospective validation

    DEFF Research Database (Denmark)

    Helt-Hansen, Jakob

    2004-01-01

    The RisøScan software is used for dose measurements with radiochromic films that color visibly. This report consists of two documents for use with the RisøScan software. The User Manual tells how to use the program and the Toolset for RetrospectiveValidation describes how to perform a retrospective...

  3. Modeling human color categorization: Color discrimination and color memory

    NARCIS (Netherlands)

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The

  4. Physical aspects of radioisotope brachytherapy

    International Nuclear Information System (INIS)

    1967-01-01

    The present report represents an attempt to provide, within a necessarily limited compass, an authoritative guide to all important physical aspects of the use of sealed gamma sources in radiotherapy. Within the report, reference is made wherever necessary to the more extensive but scattered literature on this subject. While this report attempts to cover all the physical aspects of radioisotope 'brachytherapy' it does not, of course, deal exhaustively with any one part of the subject. 384 refs, 3 figs, 6 tabs

  5. Twenty years of radioisotope production from Institute of Atomic Energy reactors

    International Nuclear Information System (INIS)

    Lun, Xiao

    1980-01-01

    The heavy water reactor in People's Republic of China went critical in November, 1958, and the radioisotope development work began since then. The thermal power of the reactor was 7 MW, and the maximum thermal neutron flux was 1.2 x 10 14 n/cm 2 /sec. Since 1967, it was operated at 10 MW. The first radioisotope product was 24 Na, using Na 2 CO 3 as a target, while the first chemically processed product was an electroplated reference source of 60 Co. The first processed radiochemical was the carrier-free H 2 SO 4 of 35 S. Since then, 131 I and 32 P for medical uses, colloidal 198 Au, colloidal Cr 32 PO 4 , chemicals containing 203 Hg, organic compounds labelled with 125 I, 131 I, 3 H and 14 C and smoke detectors have been produced to date. In addition, 22 Na, 54 Mn, 57 Co, 88 Y, 109 Cd have been prepared from a cyclotron. Now about 140 kinds of products can be supplied, and 60% of the users are the hospitals with nuclear medicine department. The present status of the kinds and production figures of nuclear medicines, radiopharmaceuticals, labelled compounds, radiation sources, and some works in progress are reported. General aspects of the application of radioisotopes in China are also described. Radioisotopes have been applied to agriculture, industry, medicine, and sciences such as physics, chemistry, biology and geography. (Wakatsuki, Y.)

  6. Experimental investigations on fiber laser color marking of steels

    Energy Technology Data Exchange (ETDEWEB)

    Amara, E.H., E-mail: amara@cdta.dz; Haïd, F.; Noukaz, A.

    2015-10-01

    Highlights: • We develop an experimental approach with the aim to bring a contribution to the comprehension of the occurring phenomena during laser color marking of steels. • We have used a home-made marking device composed of a pulsed fiber laser and galvanometric mirrors. • Both commercial and elaborated in laboratory steels have been used as samples. • The experiments have been performed for different laser beam operating parameters, under normal atmospheric conditions. • The treated samples were analyzed either by optical and scanning electronic microscopy, as well as by energy dispersion spectroscopy. - Abstract: We develop an experimental approach with the aim to bring a contribution to the comprehension of the occurring phenomena during laser color marking of steels. A home-made marking device using a pulsed fiber laser has been used to treat steel samples under different laser beam operating parameters, for different compositions of the processed steel, and at normal atmospheric conditions. The treated samples were analyzed either by optical and scanning electronic microscopy, as well as by energy dispersion spectroscopy. The results show the influence of the operating parameters on the obtained colors.

  7. Experimental investigations on fiber laser color marking of steels

    International Nuclear Information System (INIS)

    Amara, E.H.; Haïd, F.; Noukaz, A.

    2015-01-01

    Highlights: • We develop an experimental approach with the aim to bring a contribution to the comprehension of the occurring phenomena during laser color marking of steels. • We have used a home-made marking device composed of a pulsed fiber laser and galvanometric mirrors. • Both commercial and elaborated in laboratory steels have been used as samples. • The experiments have been performed for different laser beam operating parameters, under normal atmospheric conditions. • The treated samples were analyzed either by optical and scanning electronic microscopy, as well as by energy dispersion spectroscopy. - Abstract: We develop an experimental approach with the aim to bring a contribution to the comprehension of the occurring phenomena during laser color marking of steels. A home-made marking device using a pulsed fiber laser has been used to treat steel samples under different laser beam operating parameters, for different compositions of the processed steel, and at normal atmospheric conditions. The treated samples were analyzed either by optical and scanning electronic microscopy, as well as by energy dispersion spectroscopy. The results show the influence of the operating parameters on the obtained colors

  8. Radioisotope electric propulsion of sciencecraft to the outer solar system and near-interstellar space

    International Nuclear Information System (INIS)

    Noble, R.J.

    1998-08-01

    Recent results are presented in the study of radioisotope electric propulsion as a near-term technology for sending small robotic sciencecraft to the outer Solar System and near-interstellar space. Radioisotope electric propulsion (REP) systems are low-thrust, ion propulsion units based on radioisotope electric generators and ion thrusters. Powerplant specific masses are expected to be in the range of 100 to 200 kg/kW of thrust power. Planetary rendezvous missions to Pluto, fast missions to the heliopause (100 AU) with the capability to decelerate an orbiter for an extended science program and prestellar missions to the first gravitational lens focus of the Sun (550 AU) are investigated

  9. Radioisotope techniques in studies on the metabolism of calcium, iodine and iron in ruminants

    International Nuclear Information System (INIS)

    Lengemann, F.W.

    1984-01-01

    A short review is presented of radioisotopic procedures useful in research on calcium, iodine and iron studies with tropical ruminants. The procedures discussed can be useful in determining the availability of the mineral from feedstuffs, the faecal endogenous losses by the animal, detection of deficiency states, and responses to physiological and environmental stress. Methods that entail the use of radioisotopes in the laboratory or the use of stable isotopes in the animal are mentioned as alternatives to the administration of radioisotopes to the animal. While the review focuses on calcium, iodine and iron, the principles of the methods presented can be employed in the study of many other trace minerals. (author)

  10. Operation status and prospect of radioisotope production facility in HANARO

    International Nuclear Information System (INIS)

    Kim, Minjin; Jung, H.S.

    2012-01-01

    At the RIPF at HANARO, Radioisotopes for industrial and medical purpose are produced and research and development for various radioisotopes are carried out. Major products include Ir-192 for NDT, I-131 for treatment and diagnosis of thyroid cancer, Mo-99/Tc-99m Generator for imaging diagnosis of cancer. Production of radioisotope and radiopharmaceutical is being increased every year. Due to world-wide unstableness in the supply of Mo-99, a technology to produce (n,γ)Mo-99 generator at HANARO had been developed as a short term countermeasure. It will be available by the end of 2012. As a long term countermeasure, we are trying to build a new fully dedicated isotope reactor that will produce Fission Mo-99. At present, utilization of RIPF at HANARO is being increased. However when the construction of a new dedicated isotope reactor is completed in 2016, the role of the existing facility and new facility should be established accordingly so that none of the facilities are idling. In the near future, when the prospect of a utilization plan is completed, we expect an opportunity to present the result. (author)

  11. Image color reduction method for color-defective observers using a color palette composed of 20 particular colors

    Science.gov (United States)

    Sakamoto, Takashi

    2015-01-01

    This study describes a color enhancement method that uses a color palette especially designed for protan and deutan defects, commonly known as red-green color blindness. The proposed color reduction method is based on a simple color mapping. Complicated computation and image processing are not required by using the proposed method, and the method can replace protan and deutan confusion (p/d-confusion) colors with protan and deutan safe (p/d-safe) colors. Color palettes for protan and deutan defects proposed by previous studies are composed of few p/d-safe colors. Thus, the colors contained in these palettes are insufficient for replacing colors in photographs. Recently, Ito et al. proposed a p/dsafe color palette composed of 20 particular colors. The author demonstrated that their p/d-safe color palette could be applied to image color reduction in photographs as a means to replace p/d-confusion colors. This study describes the results of the proposed color reduction in photographs that include typical p/d-confusion colors, which can be replaced. After the reduction process is completed, color-defective observers can distinguish these confusion colors.

  12. Contributions and Future of Radioisotopes in Medical, Industrial and Space Applications

    Science.gov (United States)

    Tingey, G. L.; Dix, G. P.; Wahlquist, E. J.

    1990-11-01

    There are 333 isotopes that have a half-life between 1 day and 100,000 years that have a wide variety of applications including public health, medicine,industrial technology, food technology and packaging, agriculture, energy supply, and national security. This paper provides an overview of some of the most extensive applications of radioisotopes including some observations of future uses. Examples are discussed that indicate that the use of radioisotopes is almost unlimited and will continue to grow. There is a growing need for future applications development and production. 12 refs., 1 tab. (BM)

  13. Contributions and future of radioisotopes in medical, industrial and space applications

    International Nuclear Information System (INIS)

    Tingey, G.L.; Dix, G.P.; Wahlquist, E.J.

    1990-11-01

    There are 333 isotopes that have a half-life between 1 day and 100,000 years that have a wide variety of applications including public health, medicine,industrial technology, food technology and packaging, agriculture, energy supply, and national security. This paper provides an overview of some of the most extensive applications of radioisotopes including some observations of future uses. Examples are discussed that indicate that the use of radioisotopes is almost unlimited and will continue to grow. There is a growing need for future applications development and production. 12 refs., 1 tab. (BM)

  14. Contributions and future of radioisotopes in medical, industrial, and space applications

    Science.gov (United States)

    Tingey, G. L.; Dix, G. P.; Wahlquist, E. J.

    1990-11-01

    There are 333 isotopes that have a half-life between 1 day and 100,000 years that have a wide variety of applications including public health, medicine, industrial technology, food technology and packaging, agriculture, energy supply, and national security. This paper provides an overview of some of the most extensive applications of radioisotopes including some observations of future uses. Examples are discussed that indicate that the use of radioisotopes is almost unlimited and will continue to grow. There is a growing need for future applications development and production.

  15. Carrying away and redistribution of radioisotopes on the Peyne catchment basin. Preliminary report

    International Nuclear Information System (INIS)

    Duffa, C.; Danic, F.

    2006-01-01

    The transfers of radioisotopes present in soils and sediments are essentially conditioned by the mobilities of the physical vectors which constitute their supports. The water is the main vector of natural transfer, radioisotopes being associated with it under dissolved or particulate shape. The rainout and the hydrous erosion are responsible in particular for the carrying away and for the redistribution of contaminants following an atmospheric deposit on a catchment basin. However their effect is not the same in any point of the catchment basin. The work begun here aims at elaborating a classification of the grounds sensitivity towards this phenomenon of radioisotopes carrying away. The different factors of sensitivity have been identified: pluviometry, slope, soils occupation and soils nature. The Peyne catchment basin, that presents an important variability of these four parameters, constitutes the experimental site for this study. On this catchment basin, we search to identify the areas the most sensitive to the carrying away of radioisotopes, by combining a theoretical predictive approach based on the cartography and a descriptive approach basing on the sampling and the analysis of soils samples. (N.C.)

  16. A Study on Liver Scan using 113mIn Colloid

    International Nuclear Information System (INIS)

    Koh, Chang Soon; Rhee, Chong Hoen; Chang, Kochang; Hong, Chang Gi

    1969-01-01

    There have been reported numberous cases of liver scanning in use of 198 Au colloid by many investigators, however, one in use of 113m In colloid has not been reported as yet in this country. The dose of 113 mIn for high diagnostic value in examination of each organ was determined and the diagnostic interpretability of liver scanning with the use of 113m In was carefully evaluated in comparison with the results of the liver scanning by the conventionally applied radioisotope. The comparative study of both figures of liver scanning with the use of 113m In colloid and 198 Au colloid delivered following results:1) The liver uptake rate and clearance into peripheral blood were accentuated more in case of 113m In colloid than in case of 198 Au colloid. 2) The interpretability of space occupying lesion in liver scanning with 113m In was also superior to one with 198 Au. 3) The figure of liver scanning with 113m In colloid corresponds not always to the figure with 198 Au. This difference can be explained by difference of phagocytic ability of reticuloendothelial system within liver. 4) In the liver scanning with 113m In colloid, the spleen is also visualized even in normal examine. 5) In the cases of disturbed liver function, uptake is more decreased in use of 113m In colloid than in 198 Au, in the spleen, however, the way is contrary. 6) With use of 113m In colloid, the time required for scanning could be shortened in comparison with 198 Au. 7) The filtration of 113m In colloid for scanning prior to human administration gives an expectation for better scanning figure.

  17. Applications of radioisotopes for studying refractory wear-out in Bhilai Steel Plant

    International Nuclear Information System (INIS)

    Dubey, R.S.; Bose, U.P.; Shipstone, A.J.

    1979-01-01

    In Bhilai Steel Plant, investigations were carried out to study the refractory wear-out of (i) hearth bottom of blast furnaces, (ii) roof of open hearth furnaces, and (iii) hot metal mixer lining, by using radioisotope tracer techniques with a view to evaluate the life of the refractory lining at various locations and to help in planning its timely hot and cold repairs. The life of the refractory lining has the effective bearing on the overall production and hence on the economy of the plant. The two radiometric methods employed for studying the erosion of the refractory lining, by using isotope inserted bricks at various positions without damaging the lining are (i) based on recording the penetration of gamma rays emitting from the radioactive isotopes inserted at definite points of the brick lining and, (ii) by detecting the radioactivity of the pig iron or steel arising due to washing away of the respective radioactive isotopes previously inserted in the lining. In hot mixers also radioisotope sources were placed in the critical location of refractory lining and the washing out of radioisotope due to refractory brick wear out was detected by radiogauging at site. It has been found that radiotracer technique with periodic radiogauging is very useful method for tracing the radioisotope source if more than one refractory brick with isotope is placed, as in the case of open hearth furnaces. The results of radioanalysis revealed that radioactivity coming alongwith hot metal steel has been far below the permissible limit of concentration i.e. 20 micro-curie per ton of metal. Further, during dismantling of the residual refractory lining of open hearth furnaces or hot metal mixers, bricks containing radioisotopes have been successfully retrieved for safe disposal. (auth.)

  18. Clinical evaluation of Proscillaridin-A with radioisotopes

    International Nuclear Information System (INIS)

    Franco, P.D.A.; Cordovil, I.L.; Rocha, A.F.G.

    1976-01-01

    Thirty patients with cardiac insufficiency were evaluated under the use of Proscillaridin-A. The analysis was based on classic clinical parameters and 11 patients through the circulation time with the radioisotopic technique. The results obtained are analysed and discussed about the absence of side effects, considering as well the therapeutic use of the drug [pt

  19. Safe Handling of Radioisotopes. Health Physics Addendum

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, G J; Krishnamoorthy, P N

    1960-07-15

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  20. Safe Handling of Radioisotopes. Health Physics Addendum

    International Nuclear Information System (INIS)

    Appleton, G.J.; Krishnamoorthy, P.N.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  1. Digital radioisotope moisture-density meter

    International Nuclear Information System (INIS)

    Bychvarov, N.; Vankov, I.; Dimitrov, L.

    1982-01-01

    The primary information from the detectors of a combined radioisotope moisture-density meter is obtained as pulses, their counting rate being functionally dependent on the humidity per unit volume and the wet density. However, most practical cases demand information on the moisture per unit weight and the mass density of the dry skeleton. The paper describes how the proposed electronic circuit processes the input primary information to obtain the moisture in weight % and the mass density of the dry skeleton in g/cm 3 . (authors)

  2. Radioisotope studies on coconut nutrition

    International Nuclear Information System (INIS)

    Ray, P.K.

    1979-01-01

    Studies on coconut nutrition using radioisotopes are reviewed. Methods of soil placement and plant injection techniques for feeding nutrients to coconut have been studied, and irrigation practices for efficient uptake and utilization of nutrients are suggested. The absorption, distribution and translocation pattern of radioactive phosphorus and its incorporation into the nucleic acid fraction in healthy and root (wilt) diseased coconut palms have been studied. Carbon assimilation rates (using carbon-14) in spherical, semispherical and erect canopied coconut palms having different yield characteristics are reviewed and discussed. (author)

  3. A Survey on the Usage and Demand of Medical Radioisotope and Radiopharmaceuticals in Malaysia

    International Nuclear Information System (INIS)

    Muhammad Fakhrurazi Ahmad Fadzil; Siti Selina Abdul Hamid; Siti Najila Mohd Janib; Azahari Kasbollah; Syed Asraf Fahlawi Wafa

    2015-01-01

    Medical radioisotope is a small quantity of radioactive substance used in safe, cost effective, for the purpose of diagnostic and therapy of various diseases. In Malaysia, the emerging of new nuclear medicine centers or institutions in both government and private sectors rose abruptly for the past few years. Currently, there are no data available on the usage and demand of medical radioisotope or radiopharmaceuticals. Understanding the usage trending and demand of radiopharmaceuticals and medical radioisotope is essential when related to technology changes in order to meet the market size of these radiopharmaceuticals. Survey result found out that the highest demand and the highest usage among all radioisotopes are Technetium-99m and Radioiodine isotopes such as the Iodine-1331, Iodine131 MIBG, Iodine-123 and Iodine-123 MIBG. Currently, most of the medical isotopes and radiopharmaceuticals are currently imported. Technetium-99m is the backbone of nuclear medicine whereby more than 80 % of Nuclear Medicine services utilize this radioisotope. Technetium-99m supply chain is unstable globally and in coming future, two main reactors (Canada and Holland) that produces 60 % of world Molybdenum-99 will shut down the operation and supply of Molybdenum-99 will be disrupted. As for radioiodine services, currently, Iodine-123 can't be obtained in Malaysia and neighboring countries due to its short half-life, Iodine-123 is useful in diagnostic of thyroid related diseases. As for PET services, the highest demands are F-18 FDG and Gallium-68 Generator for the moment. However the survey data still did not include most of the PET centers in the Klang Valley, northern area (Penang) and the new upcoming PET center in Southern Region (Malacca and Johor). It is important for Malaysia to self-produced medical radioisotope and radiopharmaceuticals to meet the market and local demand of these medical isotopes. (author)

  4. Application of radioisotopic techniques in elucidation of the effect of nutrition on reproductive functions

    International Nuclear Information System (INIS)

    Arora, S.P.; Kaur, Harjit

    1996-01-01

    Radiotracers are an important tool in investigation of several functions and anomalies which occur in the body as a result of disturbed metabolism. Radioisotopes techniques are useful in understanding the insight which pertains to the endocrine functions in livestock reproduction. In this paper various applications of radioisotopic techniques in livestock reproduction are described. 104 refs

  5. High purity materials as targets for radioisotope production: Needs ...

    Indian Academy of Sciences (India)

    Unknown

    lity of high purity target materials, natural or enriched, are crucial for any successful radioisotope pro- gramme. Selection ... and blockages detection in buried pipelines are rendered ..... from reputed international suppliers with analysis report.

  6. Design and application of the MARK IV scanning system for radionuclide computed tomography of the brain

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Hoffman, E.J.; Phelps, M.E.; Ricci, A.; Reivich, M.

    1976-01-01

    The MARK IV radioisotope scanning system was built to provide fast and accurate radionuclide computed tomography (RCT). It is designed primarily for detecting commonly available radioactive labels such as /sup 99m/Tc, but it is also adapted to detecting positron emitters such as 18 F. The system has interlaced convergent collimation in a 4-sided arrangement of 32-independent detectors which continuously rotate as a unit, detecting, processing, and displaying the reconstructed data while the study progresses

  7. Influence of Surrounding Colors in the Illuminant-Color Mode on Color Constancy

    Directory of Open Access Journals (Sweden)

    Kazuho Fukuda

    2011-05-01

    Full Text Available On color constancy, we showed that brighter surrounding colors had greater influence than dim colors (Uchikawa, Kitazawa, MacLeod, Fukuda, 2010 APCV. Increasing luminance of a stimulus causes the change in appearance from the surface-color to the illuminant-color mode. However it is unknown whether the visual system considers such color appearance mode of surrounding colors to achieve color constancy. We investigated the influence of surrounding colors that appeared illuminant on color constancy. The stimulus was composed of a central test stimulus and surrounding six colors: bright and dim red, green and blue. The observers adjusted the chromaticity of the test stimulus to be appeared as an achromatic surface. The luminance balance of three bright surrounding colors was equalized with that of the optimal colors in three illuminant conditions, then, the luminance of one of the three bright colors was varied in the range beyond the critical luminance of color appearance mode transition. The results showed that increasing luminance of a bright surrounding color shifted the observers' achromatic setting toward its chromaticity, but this effect diminished for the surrounding color in the illuminant-color mode. These results suggest that the visual system considers color appearance mode of surrounding colors to accomplish color constancy.

  8. Radioisotope techniques in water resources research and management with special reference to India

    International Nuclear Information System (INIS)

    Banerji, S.

    1977-01-01

    Nuclear techniques using radioisotopes finding applications in research and management of water resources are described briefly with special reference to and representative illustrations of their applications in hydrologic studies in India. As environmental isotopes including the man-made ones i.e. those released in nuclear explosions are intimately tied with the moisture and water in circulation pattern in nature, measurement of their variation provides diagnostic information about the hydrologic parameters of three phases, namely, atmospheric, surface and subsurface, of the hydrologic cycle. Artificial radioisotopes are used for measurement of water flow, sediment transport and seepage. Sealed radioisotope sources are employed in snow gauging, suspended sediment gauging and hydrologic logging. Areas for further research are suggested and need for emphasis on their use in India is indicated. (M.G.B.)

  9. Study of surface potential contamination in radioisotope and radiopharmaceutical production facilities and alternative solutions

    International Nuclear Information System (INIS)

    Suhaedi Muhammad; Rimin Sumantri; Farida Tusafariah; Djarwanti Rahayu Pipin Soedjarwo

    2013-01-01

    Radioisotope and radiopharmaceutical production facilities that exist in their operations around the world in the form of radiological impacts of radiation exposure, contamination of surface and air contamination. Given the number of existing open source in radioisotope and radiopharmaceutical production facility, then the possibility of surface contamination in the work area is quite high. For that to protect the safety and health of both workers, the public and the environment, then the licensee must conduct an inventory of some of the potential that could result in contamination of surfaces in radioisotope and radiopharmaceutical production facilities. Several potential to cause surface contamination in radioisotope and radiopharmaceutical production facilities consist of loss of resources, the VAC system disorders, impaired production facilities, limited resources and lack of work discipline and radioactive waste handling activities. From the study of some potential, there are several alternative solutions that can be implemented by the licensee to address the contamination of the surface so as not to cause adverse radiological impacts for both radiation workers, the public or the environment. (author)

  10. Radioisotope requirements and usage in the radiopharmaceutical industry

    International Nuclear Information System (INIS)

    Langton, M.A.

    1995-01-01

    Radioisotopes are used extensively in many different productive and beneficial human endeavors. Amersham International, a U.K.-based company originating in the British Scientific Civil Service during World War II, has been actively involved in many of these activities for more than 50 yr. Today they are one of the world's largest suppliers of radioactive compounds and scaled radiation sources for use in industrial quality and safety assurance, life science research, and medicine. This paper outlines one of these applications: the use of radioisotopes as radiopharmaceuticals. Radiopharmaceuticals are radioactive nuclides and labeled compounds that have been developed for the diagnosis and treatment of (human) disease. They are manufactured via highly controlled processes and have gone through regulatory scrutiny and approval far in excess of other radioisotopes used in other applications. Radiopharmaceuticals can be conveniently split into two categories. One type is simply an active analog that mimics the physiological behavior of its inactive counterpart in the body. The other involves an actual pharmacological compound that exhibits the desired physiological behavior, which is then labeled with a radionuclide suitable for either imaging or the delivery of a therapeutic radiation dose as appropriate but which plays no part in the mechanism of action of the drug. The latter type, which is the more common of the two, can be supplied either as an active compounded product or as a open-quotes cold kit,close quotes which is then labeled with the appropriate radiopharmaceutical-grade radionuclide to yield the final product

  11. The production of cyclotron radioisotopes and radiopharmaceuticals at the national accelerator centre in South Africa

    International Nuclear Information System (INIS)

    Walt, T.N. van der

    1998-01-01

    Accelerator radioisotopes have been manufactured in South Africa since 1965 with the 30 MeV cyclotron at the Council for Scientific and Industrial Research (CSIR) in Pretoria. After its closure in 1988, the radioisotope production programme was continued at the National Accelerator Centre (NAC) with the 200 MeV separated sector cyclotron (SCC) utilizing the 66 MeV proton beam, which is shared with the neutron therapy programme during part of the week. A variety of radiopharmaceuticals, such as 18 F-FDG, 67 Ga-citrate, a 67 Ga-labelled resin. 111 In-chloride, 111 In-oxine and 111 In-labelled resin. 123 I-sodium iodide and 123 I-labelled compounds, 201 Tl-chloride, as well as the 81 Rb/ 81m Kr gas generator, are prepared for use in the nuclear medicine departments of 12 State hospitals and about 28 private nuclear medicine clinics in South Africa. A few longer-lived radioisotopes, such as 22 Na, 55 Fe and 139 Ce, are also produced for research or industrial use. A research and development programme is running to develop new production procedures to produce radioisotopes and radiopharmaceuticals, or to improve existing production procedures. As part of a programme to utilize the beam time optimally, the production of some other radioisotopes is investigated. (author)

  12. Real-time three-dimensional surface measurement by color encoded light projection

    International Nuclear Information System (INIS)

    Chen, S. Y.; Li, Y. F.; Guan, Q.; Xiao, G.

    2006-01-01

    Existing noncontact methods for surface measurement suffer from the disadvantages of poor reliability, low scanning speed, or high cost. The authors present a method for real-time three-dimensional data acquisition by a color-coded vision sensor composed of common components. The authors use a digital projector controlled by computer to generate desired color light patterns. The unique indexing of the light codes is a key problem and is solved in this study so that surface perception can be performed with only local pattern analysis of the neighbor color codes in a single image. Experimental examples and performance analysis are provided

  13. Potential medical applications of the plasma focus in the radioisotope production for PET imaging

    International Nuclear Information System (INIS)

    Roshan, M.V.; Razaghi, S.; Asghari, F.; Rawat, R.S.; Springham, S.V.; Lee, P.; Lee, S.; Tan, T.L.

    2014-01-01

    Devices other than the accelerators are desired to be investigated for generating high energy particles to induce nuclear reaction and positron emission tomography (PET) producing radioisotopes. The experimental data of plasma focus devices (PF) are studied and the activity scaling law for External Solid Target (EST) activation is established. Based on the scaling law and the techniques to enhance the radioisotopes production, the feasibility of generating the required activity for PET imaging is studied. - Highlights: • Short lived radioisotopes for PET imaging are produced in plasma focus device. • The scaling law of the activity induced with plasma focus energy is established. • The potential medical applications of plasma focus are studied

  14. High radio-isotope uptakes in patients with hypothyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Wing, J.; Kalk, W.J.; Ganda, C. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Medicine)

    1982-12-04

    Hypothyroidism is usually associated with a low radio-isotope uptake by the thyriod gland. We report 8 cases of Hashimoto's thyroiditis with clinical and biochemical hypothyroidism and with borderline high or overtly increased technetium-99m pertechnetate and/or iodine-131 uptakes.

  15. Preparing for Harvesting Radioisotopes from FRIB

    Energy Technology Data Exchange (ETDEWEB)

    Peaslee, Graham F. [Hope College, Holland, MI (United States); Lapi, Suzanne E. [Washington Univ., St. Louis, MO (United States)

    2015-02-02

    The Facility for Rare Isotope Beams (FRIB) is the next generation accelerator facility under construction at Michigan State University. FRIB will produce a wide variety of rare isotopes by a process called projectile fragmentation for a broad range of new experiments when it comes online in 2020. The accelerated rare isotope beams produced in this facility will be more intense than any current facility in the world - in many cases by more than 1000-fold. These beams will be available to the primary users of FRIB in order to do exciting new fundamental research with accelerated heavy ions. In the standard mode of operation, this will mean one radioisotope will be selected at a time for the user. However, the projectile fragmentation process also yields hundreds of other radioisotopes at these bombarding energies, and many of these rare isotopes are long-lived and could have practical applications in medicine, national security or the environment. This project developed new methods to collect these long-lived rare isotopes that are by-products of the standard FRIB operation. These isotopes are important to many areas of research, thus this project will have a broad impact in several scientific areas including medicine, environment and homeland security.

  16. Drying equipment for radioisotope-treated animals

    International Nuclear Information System (INIS)

    Fujikake, Toshio; Ohmori, Akira; Takada, Yukio; Nakano, Shozoh; Tamai, Shinsuke.

    1978-01-01

    The animal experiments using radioisotopes have been carried out over wide fields, accordingly, the number of radioisotope-contaminated animal cadavers has been increasing rapidly. It was decided that each establishment employing radioiosotopes dries those cadavers to such state as to be able to burn up with the device in Japan Atomic Energy Research Institute. The animal waste-drying device meeting the above mentioned purpose was developed by the joint work of Fuji Electric General Devices Co. and Fuji Electric Co. It is known as the micro-wave drying device for animals (its nickname is Microdry). This device dehydrates at high speed by micro-wave drying method. By using along with a moisture detector, it gives the drying state as requested regardless of the water content of each animal. The animal wastes after perfect dehydration are reduced to the weight of about one-third, and the dried animal cadavers can be preserved for a long time at room temperature because of the sterilizing effect of the micro-wave heating. This device is noted for its excellent safeness, simple operation, and low treatment cost. It is anticipated that it can be further applied to other fields such as excreta, breeding materials, etc. (Kobatake, H.)

  17. Report of Radioisotope Inspection Technical Committee

    International Nuclear Information System (INIS)

    Otani, H.

    1980-01-01

    For the purpose of unifying the method of performance test for the routine management of the performance of RI equipments, the check-up of performance at the time of purchasing the equipments or research works, the Committee has continued the investigation on the method of performance test on RI equipments. Now, the definite plans have been decided regarding the method of performance test on radioisotope monitoring instruments and the measuring instruments for RI samples, therefore they are reported hereinafter. As for the radioisotope monitoring instruments, Curie meter, area monitor, water monitor, gas monitor and hand, foot and cloth monitor were taken up, and the items of inspection, the purposes, the testing methods, the expression of measured results and their evaluation were discussed. The accuracy of measurement of absolute radio-activity is important in Curie meter, the stability of continuous monitoring is important in general monitors, and the limit of measurement is important in the hand, foot and cloth monitor. As for the measuring instruments for radioactive materials, the efficiency of counting, linearity and stability were taken up as the items of performance test, and other matters to which attention should be paid were added. These were described, dividing into well type scintillation counter and liquid scintillation counter. (Kako, I.)

  18. Radioisotope bone scanning in horses

    International Nuclear Information System (INIS)

    Attenburrow, D.P.; Bowring, C.S.; Vennart, W.

    1984-01-01

    The detection of radionuclide activity in the living equine skeleton, using bone seeking radiopharmaceuticals and a hand-held radiation detector, is reported. Pathological changes in bone can be detected and subsequent development monitored. The availability and use of this diagnostic technique in equine practice is discussed

  19. Radioisotope implantation with a new facility at the Australian Defence Force Academy

    International Nuclear Information System (INIS)

    Shrestha, S.K.; Chaplin, D.H.; Edge, A.V.J.; Hutchison, W.D.; Timmers, H.; Byrne, A.P.

    2003-01-01

    A 50 - 155 keV ion implanter is being developed on the campus of the University of New South Wales at the Australian Defence Force Academy for the implantation of radioisotopes as part of a UNSW/ANU collaboration. The facility employs a versatile SNICS II negative ion source. Commissioning tests have shown the facility to efficiently produce, mass-select, and transport negative ion beams of various stable isotopes. The mass resolution has been demonstrated to be better than 1 amu and the implantation of stable isotopes was verified with Elastic Recoil Detection (ERD) analysis. Recently, the first implantation of radioactive 111 In has been performed successfully. The routine implantation of this and other radioisotopes is envisaged to support analytical techniques in the material sciences, such as Perturbed Angular Correlation (PAC) spectroscopy and Nuclear Magnetic Resonance of Oriented Nuclei (NMRON), and to possibly study the controlled activation of medical implants and the diffusion of radioisotopes in materials

  20. The Current Utilization and Future Demand of Radiopharmaceutical and Radioisotopes in Malaysia

    International Nuclear Information System (INIS)

    Ibrahim Ijang; Zakaria Ibrahim; Bohari Yaacob

    2013-01-01

    Radioisotope and pharmaceutical kits play an important role in nuclear medicine for non-invasive diagnosis and treatment of various cancers and cardiovascular disease. Our aim was to survey the current utilization and future demand of radiopharmaceuticals and radioisotopes in Malaysia. The survey methodology technique was done using questionnaire administration modes. The survey was done for four month duration from government hospitals that have nuclear medicine department. The most frequent pharmaceutical kits used in hospitals were Methylene Diphosphonic acid (MDP) for bone imaging and Diethylene Triamine Pantacetic acid (DTPA). Similarly radioisotopes widely used were Tc-99m and Iodine 131.Therefore if produced of Tc-99m by Nuclear Malaysia can improved in term of high quality products, Nuclear Malaysia could be the sole supplier of this product to hospitals in Malaysia. Similarly pharmaceutical kits especially MDP and DTPA, Nuclear Malaysia has the expertise and knowledge to supply these kits to the hospital. (author)

  1. Current status of utilization of radioisotopes and radiation technology in Malaysia

    International Nuclear Information System (INIS)

    Ahmad Tajuddin Ali

    1985-01-01

    The utilization of isotope and radiation technology in Malaysia dates back to the early sixties. However it was confined to the field of medicine. Today, the use of this technology has widen up, covering the agricultural and industrial areas. The increasing use of the technology has prompted the government to establish the Nuclear Energy Unit whose one of its main functions is to ensure the safe application of radioisotopes and radiations. For this purpose, facilities for training, calibration, waste treatment, etc. were provided by this unit to cater the need of radioisotope and radiation users throughout the country. (author)

  2. Current status and recent developments of industrial radioisotope applications in Japan

    International Nuclear Information System (INIS)

    Tominaga, Hiroshi

    1985-01-01

    The current status of application of radioisotopes to industry in Japan is briefly reviewed. Radioisotope gauges are widely used in industry, but most of the radioactive tracer applications are performed in laboratories. as for the recent developments, it is noted that the majority of them are related to high technologies in industry. Some typical examples are described. They include: high accuracy coke moisture guage--dual channel gauging on-line analyzers based on 252 Cf, simultaneous neutron and gamma radiography; tracer techniques in civil engineering field, electronics industry, automobile industry and iron and steel industry.(M.G.B.)

  3. Investigation of Insulation Materials for Future Radioisotope Power Systems (RPS)

    Science.gov (United States)

    Cornell, Peggy A.; Hurwitz, Frances I.; Ellis, David L.; Schmitz, Paul C.

    2013-01-01

    NASA's Radioisotope Power System (RPS) Technology Advancement Project is developing next generation high temperature insulation materials that directly benefit thermal management and improve performance of RPS for future science missions. Preliminary studies on the use of multilayer insulation (MLI) for Stirling convertors used on the Advanced Stirling Radioisotope Generator (ASRG) have shown the potential benefits of MLI for space vacuum applications in reducing generator size and increasing specific power (W/kg) as compared to the baseline Microtherm HT (Microtherm, Inc.) insulation. Further studies are currently being conducted at NASA Glenn Research Center (GRC) on candidate MLI foils and aerogel composite spacers. This paper presents the method of testing of foils and spacers and experimental results to date.

  4. Present status of application of radiation and radioisotopes in Bangladesh

    International Nuclear Information System (INIS)

    Hossain, Anwar

    1984-01-01

    Bangladesh has proceeded with the atomic energy programme in three phases: (1) research and development using radiation and radioisotopes and application of the results, (2) building the infrastructure in nuclear technology and (3) production of electricity from nuclear sources and development of associated facilities. It has entered the second phase of the programme. The following main areas of research and application were referred to: agriculture, food preservation, medical sterilization and radiation biology, medicine, non-destructive testing, isotope hydrology, elemental analysis, particle-induced x-ray emission (PIXE) methods, radioisotope-induced x-ray fluorescence (RIXFA) methods, flame atomic absorption spectrophotometric (AAS) methods, molecular absorption and fluorescence spectroscopy, health physics, and future programme with research reactor. (Namekawa, K.)

  5. Environmental assessment for radioisotope heat source fuel processing and fabrication

    International Nuclear Information System (INIS)

    1991-07-01

    DOE has prepared an Environmental Assessment (EA) for radioisotope heat source fuel processing and fabrication involving existing facilities at the Savannah River Site (SRS) near Aiken, South Carolina and the Los Alamos National Laboratory (LANL) near Los Alamos, New Mexico. The proposed action is needed to provide Radioisotope Thermoelectric Generators (RTG) to support the National Aeronautics and Space Administration's (NASA) CRAF and Cassini Missions. Based on the analysis in the EA, DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, an Environmental Impact Statement is not required. 30 refs., 5 figs

  6. The analogy research study on gamma radiation dose rate of radioisotopes 131Ba and 131I

    International Nuclear Information System (INIS)

    Hu Youhua; Feng Guangwen

    2013-01-01

    Analogy is a inference method ,according some properties of a class of things to inferring the similar things should also have the similar properties. The analogy of same radionuclides is widely used in radioisotope logging environment impact assessment so far. This paper is to provide fFor future providing a theoretical calculation method and analogy method between different radionuclides in radioisotope logging environment impact assessment. In this paper, using the latest decay scheme, through theoretical modeling, the aim is the the establishment of 131 Ba and 131 I radioisotopes gamma radiation dose rate calculation method, and try to carry out analogy research on gamma radiation dose rate of different radioisotopes with the same activity. The results show that the analogy of different radionuclides is feasible, which provides the new method reference for carrying out such radiation environmental impact assessment in future. (authors)

  7. The industrial application of radioisotopes

    International Nuclear Information System (INIS)

    Frevert, E.

    1991-01-01

    In this paper the two main fields of the industrial application of radioisotopes are introduced. In the field of process controlling device and control first about the transmission and the backscattering methods is reported. Then the x-ray fluorescence method and the moisture gauging with neutrons are mentioned. Also the measuring of depth of charge. In the field of tracer investigations about all kinds of flow and intermixture measurements is reported. And investigations of corrosion, wear and lubrication and precise location of nonmetallic pipe lines are mentioned. (Author)

  8. Artificial radioisotopes in hydrological investigation

    International Nuclear Information System (INIS)

    Plata-Bedmar, A.

    1988-01-01

    Radioisotope techniques have an important part in hydrological investigations. Sealed radiation sources have been used for measurements of sediments transported by river water, of thickness and density of sediment layers. X-ray fluorescence analysis and well-logging are widely applied in hydrological research. Tracer techniques have been useful in flow rate and river dynamics research, sediments tracing, irrigation and ground water problems, infiltration rate evaluation etc. The IAEA is supporting several projects involving the use of radioactive tracers in hydrological investigations p.e. in Guatemala, Romania, South East Asia, Brazil, Chile and Nicaragua

  9. Optimal scanning and image processing with the STEM

    International Nuclear Information System (INIS)

    Crewe, A.V.; Ohtsuki, M.

    1981-01-01

    We have recently published a theory of an optimal scanning system which is particularly suited for the STEM. One concludes from the theory that the diffraction limit of the electron probe should be a fixed fraction of the full-scale deflection in order to avoid scanning artifacts. More recently, we have confirmed the value of this technique by direct experiments. Our program now is to combine the use of optimal scanning with the use of a programmable digital refresh memory for image analysis. Limited experience to date indicates that false color conversion is probably more useful than histogram equalization in black and white and that this system is particularly valuable for rotational averaging and selected area Fourier transforms. (orig.)

  10. Radioisotopes in the treatment of cancer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1962-01-15

    Radiation treatment of malignant growths is not, of course, a novel procedure; both radium implants and X-rays generated at medium voltages (up to 250 kV) have been used all over the world for many years. However, large scale production of radioisotopes in atomic reactors has made radiotherapy available for the first time in less developed areas of the world. Moreover, the treatment has been simplified and, in many cases, made more effective

  11. Visualization of Radioisotope Detectability Over Time.

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, Brady [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-02-01

    A radioactive isotope is an atom that has an unstable nucleus. The isotope can undergo radioactive decay, the process in which excessive nuclear energy is emitted from the nucleus in many different forms, such as gamma radiation, alpha particles, or beta particles. The important thing to note is that these emissions act as a signature for the isotope. Each radioisotope has a particular emission spectrum, emitting radiation at different energies and at different rates.

  12. Industrial radiation and radioisotope gauging techniques and applications

    International Nuclear Information System (INIS)

    Gardner, R.P.

    1997-01-01

    The radiation and radioisotope gauging industry in the United States has primarily followed a path of development solely by the private sector. It has remained highly proprietary in nature, which is opposite to the path taken by many other countries. In other countries radiation gauge development has been controlled in large part by government-sponsored research and development, which has spawned many more publications in the open literature. Historically, some of the leaders have been Great Britain, Poland, France, Russia, and Australia. This has possibly led to the misconception that the development of this technology is being dominated by countries outside the United States. This is not a healthy situation-it would be good to see our industry begin to publish more in the open literature and to sponsor more research at universities. In efforts to promote more open-literature publication, the American Nuclear Society (ANS) sponsored a topical meeting on Industrial Radiation and Radioisotope Measurement Applications (IRRMA) in 1988 that was held again in 1992

  13. Hydrological model for the transport of radioisotope in surface water

    International Nuclear Information System (INIS)

    Adoboah, E.K.

    2011-01-01

    The use of radioisotopes has gained grounds in Ghana as a result of the numerous benefits that could be derived from it. In Ghana, radioisotope materials are used for various purposes in a number of institutions. However, improper disposal of the waste poses threat to the environment. To evaluate the environmental impact of radioisotope pollution, mathematical models play a major role in predicting the pollution level in any medium. This study is concerned with the hydrological model for the transport of radioactive material in the river. The model was composed by employing partial differential equations, describing relevant physical processes evolution (water level, velocities and dissolved substances concentrations) that occurs in water bodies. The mass conservation and momentum laws, state equation and state transport equations are equation system basis. The explicit central difference scheme in space and a forward difference method in time were used for the evaluation of the generalized transport equation, the Advection-Dispersion Equation. A Matlab code was developed to predict the concentration of the radioactive contaminant at any particular time along the river and in a reservoir. The model was able to simulate accurately the various levels of radionuclide concentration changes in the flowing rivers as the flows are augmented by tributary inflows. (au)

  14. IRAS Colors of the Pleiades

    Science.gov (United States)

    Carey, Sean J.; Shipman, R. F.; Clark, F. O.

    1996-01-01

    We present large scale images of the infrared emission of the region around the Pleiades using the ISSA data product from the IRAS mission. Residual Zodiacal background and a discontinuity in the image due to the scanning strategy of the satellite necessitated special background subtraction methods. The 60/100 color image clearly shows the heating of the ambient interstellar medium by the cluster. The 12/100 and 25/100 images peak on the cluster as expected for exposure of small dust grains to an enhanced UV radiation field; however, the 25/100 color declines to below the average interstellar value at the periphery of the cluster. Potential causes of the color deficit are discussed. A new method of identifying dense molecular material through infrared emission properties is presented. The difference between the 100 micron flux density and the 60 micron flux density scaled by the average interstellar 60/100 color ratio (Delta I(sub 100) is a sensitive diagnostic of material with embedded heating sources (Delta I(sub 100) less than 0) and cold, dense cores (Delta I(sub 100) greater than 0). The dense cores of the Taurus cloud complex as well as Lynds 1457 are clearly identified by this method, while the IR bright but diffuse Pleiades molecular cloud is virtually indistinguishable from the nearby infrared cirrus.

  15. How to find out in radioisotope methodology

    International Nuclear Information System (INIS)

    Evers, C.

    1976-01-01

    The subject is dealt with in sections entitled: tracing books by topic; radioisotope methodology cross reference structure; finding a review; journals and how to trace journal articles; abstract; theses and dissertations; research and development reports; critical reviews and information summaries; data books; dictionaries and encyclopedias; guides to the literature; whom to contact; expert advice, research in progress, institutions. (U.K.)

  16. The industrial application of radioisotopes in Australia

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    Over the past 10 years, the Australian Atomic Energy Commission has conducted a wide-ranging program of radioisotope applications to solve industrial problems of local, regional or national importance. Most of the investigations have been concerned with the behaviour of large complex systems. Broadly, the work covers such economically important fields as flow studies, environmental studies and coastal engineering studies. (author)

  17. Lethality of radioisotopes in early mouse embryos

    International Nuclear Information System (INIS)

    Macqueen, H.A.

    1979-01-01

    The development of pre-implantation mouse embryos was found to be prevented by exposure of the embryos to [ 35 S]methionine, but not to [ 3 H]methionine. Such embryos have also been shown to be highly sensitive to [ 3 H]thymidine. These observations are discussed with reference to the path lengths and energies of electrons emitted from the different radioisotopes. (author)

  18. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  19. Thermal Model Predictions of Advanced Stirling Radioisotope Generator Performance

    Science.gov (United States)

    Wang, Xiao-Yen J.; Fabanich, William Anthony; Schmitz, Paul C.

    2014-01-01

    This presentation describes the capabilities of three-dimensional thermal power model of advanced stirling radioisotope generator (ASRG). The performance of the ASRG is presented for different scenario, such as Venus flyby with or without the auxiliary cooling system.

  20. Utilization of radioisotopes in France, present and future

    International Nuclear Information System (INIS)

    Gauvenet, A.J.

    1976-01-01

    France is one of the countries having used radioisotopes very early. The first research reactor went critical in 1948, and has been used right from the start mainly to produce the radioisotopes for research and medicine. The growth in production was extremely fast, and the net receipts (excluding tax) amounted to F.52.3 million during 1974, of which F.20.9 million from export. The increase as compared with 1973 is 33%. The research and production facilities, which are concerned with medical applications, are in full expansion, Finally, the increasing use of trans-uranic elements, particularly of Pu-238 pacemakers, is noted. The uses of Cm-244 and Cf-252 are also growing. The problem at user level that undoubtedly requires the greatest attention is the regulations. The regulations on radioelements in France are reviewed in details on the following matters; poisonous substances, radioactive transport, waste, license for using artificial radioactive substances, etc. As the conclusion, the extremely ripid growth in the use of radioisotopes - mainly artificial ones - brought about the problems of adaptation with respect to the control and training regulations. One of the problems is obviously due to the fact that the personnel using such substances does not possess the specialization, training and managerial staff which marks the nuclear industry proper. It is therefore of prime significance to give unfailing attention to this use which is becoming the matter of major importance in France. The stress now placed on everything that concerns radiation has the great interest of forcing renewed awareness, thereby avoiding the degradation that the routine might bring. (Kobatake, H.)

  1. A Study on the Effects of Position Change on the Liver Shape on Radioisotope Scan

    International Nuclear Information System (INIS)

    Hong, Kee Suk; Choi, Du Hyok; Yang, Young Tae; Koh, Chang Soon

    1982-01-01

    For this study, the authors obtained and examined anterior views of the liver and spleen in two different positions, upright and supine, of 39 normal subjects and 20 patients with hepatic pathology by means of 99m Tc-colloid and gamma camera. This examination confirms the following findings. In general, it is shown, left lobe of the liver in upright position becomes longer in height than in supine position, while the distance between lateral margin of the liver and that of spleen becomes father in with in supine position than in upright position. The upper margin of liver moves more downward in upright position than in supine. It is noticeable that as for 5 cases with severe chronic liver disease, there is minimal alteration of the liver shape between in two positions. The comparison of the both positions for the better liver scan shows the following findings. Prominent caudate and/or left lobe are marked in the upright position in 16 cases out of the total 59, while none is found in the supine. The false cold area in lower part of the liver disappears in 7 cases in the upright position, while only one shows the disappearance of the false cold area in the supine. Left liver margin due to close contact of spleen is blurred in 3 cases in the upright position. In total 23 cases out of 59 support that the upright position is better for the liver scan, while only 4 cases support the supine position is better. These findings support two assumptions. One is that upright view can be expected more improved resolution than supine view for liver scan. Second is that minimal change of the liver shape in both views indicate the serious abnormality in the liver.

  2. Advanced Radiative Emitters for Radioisotope Thermophotovoltaic Power Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Radioisotope Power Systems (RPS) are critical for future flagship exploration missions in space and on planetary surfaces. Small improvements in the RPS performance,...

  3. Preparation of the Nanostructured Radioisotope Metallic Oxide by Neutron Irradiation for Use as Radiotracers

    Directory of Open Access Journals (Sweden)

    Sang-Ei Seo

    2017-10-01

    Full Text Available Metallic oxides manganese dioxide (MnO2, samarium oxide (Sm2O3, and dysprosium oxide (Dy2O3 with nanorod-like structures were synthesized by the hydrothermal synthesis method, respectively. Subsequently, the nanostructured radioisotopes MnO2 with Mn-56, Sm2O3 with Sm-153, and Dy2O3 with Dy-165 were prepared by neutron irradiation from the HANARO research reactor, respectively. The three different elements, Mn, Sm, and Dy, were selected as radiotracers because these elements can be easily gamma-activated from neutrons (activation limits: 1 picogram (Dy, 1–10 picogram (Mn, 10–100 picogram (Sm. Furthermore, the synthesized radioisotopes can be used as radiotracers in Prompt Gamma Neutron Activation Analysis as the rare earth metals Dy and Sm were not present in the Korean environment. The successful synthesis of the radioisotope metallic oxides was confirmed by Transmission Electron Microscopy (TEM, Energy Dispersive X-ray Spectrometry (EDS, X-ray Diffraction (XRD analysis, and gamma spectroscopy analysis. The synthesized nanostructured radioisotope metallic oxides may be used as radiotracers in scientific, environmental, engineering, and industrial fields.

  4. Safety management of radioisotopes and others in educational institutions

    International Nuclear Information System (INIS)

    1981-01-01

    Radioisotopes are extensively used in the fields of research in various educational institutions. While considerable progress has been seen in the safety management of RI utilization, such accidents as the loss of radioisotopes and radioactive contamination occurred. Under the situation, the safety management of RIs and others in RI-using facilities provided by the law has been examined by the ad hoc committee. A report by the committee is described as follows: need for a RI safety management organization, defining the responsibility of the chief technicians handling radiation, need for the practices of using RIs, etc. in education and traininng, planned RI-handling facilities, cautions for the loss of RIs and the contamination, centralization in RI safety management, improvement of remuneration for the chief technicians handling radiation, occasional restudy on the safety management of RIs, etc. (J.P.N.)

  5. Process for radioisotope recovery and system for implementing same

    Science.gov (United States)

    Meikrantz, David H [Idaho Falls, ID; Todd, Terry A [Aberdeen, ID; Tranter, Troy J [Idaho Falls, ID; Horwitz, E Philip [Naperville, IL

    2009-10-06

    A method of recovering daughter isotopes from a radioisotope mixture. The method comprises providing a radioisotope mixture solution comprising at least one parent isotope. The at least one parent isotope is extracted into an organic phase, which comprises an extractant and a solvent. The organic phase is substantially continuously contacted with an aqueous phase to extract at least one daughter isotope into the aqueous phase. The aqueous phase is separated from the organic phase, such as by using an annular centrifugal contactor. The at least one daughter isotope is purified from the aqueous phase, such as by ion exchange chromatography or extraction chromatography. The at least one daughter isotope may include actinium-225, radium-225, bismuth-213, or mixtures thereof. A liquid-liquid extraction system for recovering at least one daughter isotope from a source material is also disclosed.

  6. Processing of Color Words Activates Color Representations

    Science.gov (United States)

    Richter, Tobias; Zwaan, Rolf A.

    2009-01-01

    Two experiments were conducted to investigate whether color representations are routinely activated when color words are processed. Congruency effects of colors and color words were observed in both directions. Lexical decisions on color words were faster when preceding colors matched the color named by the word. Color-discrimination responses…

  7. Theory of isotope scanning; Theorie de l'Exploration par les Radioisotopes; Teoriya meditsinskikh issledovanij s primeneniem izotopov; Teoria de la exploracion mediante radioisotopos

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G L [Physics Research Laboratory, Massachusetts General Hospital, Boston, MA (United States)

    1959-07-01

    The visualization of isotope distributions is an important aspect of the medical use of radioisotopes. The sensitivity patterns of various collimating systems are compared and their efficiency and resolution calculated. The collimating systems considered consist of cylindrical and tapered apertures, focusing collimators, and coincidence detection of annihilation radiation. A general theory is derived to give the optimum isotope concentration for each of the systems. A similar theory is derived to cover the scintillation camera and a comparison is made of the optimum isotope concentration of this device in relation to scanning methods. A modification of the camera concept for use with annihilation radiation is discussed. Various recording systems are compared as to efficiency and information presentation. (author) [French] La representation visuelle de la repartition des isotopes est un aspect important de l'utilisation des radioisotopes en medecine. L'auteur compare les types de sensibilite de divers systemes de collimation et calcule leur efficacite et leur pouvoir de resolution. Les systemes consideres se composent d'orifices cylindriques ou coniques, de collimateurs a focalisation et des dispositifs permettant de detecter par coincidences les rayonnements d'annihilation. Il en tire une theorie generale en vue de donner la concentration optimum d'isotopes pour chacun de ces systemes. L'auteur expose une theorie analogue pour la chambre a scintillations et procede a une comparaison de la concentration optimum d'isotopes dans le cas de cet appareil, par rapport aux resultats obtenus au moyen des methodes d'exploration. Il etudie la possibilite de modifier le principe de la chambre pour l'appliquer a la detection des rayonnements d'annihilation. Il compare divers systemes d'enregistrement du point de vue de leur efficacite et de la presentation des renseignements. (author) [Spanish] La representacion visual de la distribucion de los isotopos constituye un importante

  8. Color categories and color appearance

    Science.gov (United States)

    Webster, Michael A.; Kay, Paul

    2011-01-01

    We examined categorical effects in color appearance in two tasks, which in part differed in the extent to which color naming was explicitly required for the response. In one, we measured the effects of color differences on perceptual grouping for hues that spanned the blue–green boundary, to test whether chromatic differences across the boundary were perceptually exaggerated. This task did not require overt judgments of the perceived colors, and the tendency to group showed only a weak and inconsistent categorical bias. In a second case, we analyzed results from two prior studies of hue scaling of chromatic stimuli (De Valois, De Valois, Switkes, & Mahon, 1997; Malkoc, Kay, & Webster, 2005), to test whether color appearance changed more rapidly around the blue–green boundary. In this task observers directly judge the perceived color of the stimuli and these judgments tended to show much stronger categorical effects. The differences between these tasks could arise either because different signals mediate color grouping and color appearance, or because linguistic categories might differentially intrude on the response to color and/or on the perception of color. Our results suggest that the interaction between language and color processing may be highly dependent on the specific task and cognitive demands and strategies of the observer, and also highlight pronounced individual differences in the tendency to exhibit categorical responses. PMID:22176751

  9. Dynamic Studies with Radioisotopes in Medicine. Proceedings of the Symposium on Dynamics Studies with Radioisotopes in Clinical Medicine and Research

    International Nuclear Information System (INIS)

    1971-01-01

    Observations on the temporal patterns of uptake, metabolism, clearance or excretion of administered radioactive materials form the basis of many important applications of radioisotopes in clinical medicine and research. Such applications include studies of organ function, of regional blood flow and of the turnover of various substances in the human body. Newly available radioisotopes, new instruments such as gamma came ras, new techniques and new methods of data analysis based on the use of analogue and digital computers are continually enlarging the scope of the applications. Progress in these matters was discussed at the Symposium on Dynamic Studies with Radioisotopes in Clinical Medicine and Research, organized by the lnternational Atomic Energy Agency and held in Rotterdam, The Netherlands, from 31 August to 4 September 1970. A total of 315 participants nominated by 39 countries and 4 international organizations attended, and the 70 papers presented cove r the theoretical aspects of dynamic studies, the development of techniques and instruments for such studies, and specific applications in studies of thyroid, renal, hepatic and splenic function, mineral metabolism, regional blood flow, and cardiac and pulmonary function. The proceedings include the full texts of all the papers presented together with the edited discussions. Invited review papers deal with the general aspects of the various main groups of applications covered. Many of the applications described have already reached the stage of routine use; others are still in the developmental stage. Of particular note in the latter connection are applications based on the quantitative analysis of scintillation camera data. The many papers presented on these topics and the ensuing discussions indicate the great interest now shown in this promising area of development. It is hoped that the proceedings will provide a valuable guide to the present status of the subject

  10. Utilization of radioisotopes in the agriculture

    International Nuclear Information System (INIS)

    Cerri, C.C.

    1987-01-01

    Some aspects of radioisotopes utilization in the agriculture, such as, the use of gamma radiation for genetic improvement of plants; the use of C 14 as tracer for comprehension of the vegetable physiology; the use of nitrogen and phosphorus isotopes in soil fertilization and plant nutrition; the use of radiation for inset sterelization and, measurement of the humidity and density of soils by neutron moderation and attenuation of gamma radiation, are presented. (M.C.K.) [pt

  11. A radioisotope production cyclotron designed to minimize dose

    International Nuclear Information System (INIS)

    Szlavik, F.F.; Moritz, L.E.

    1992-01-01

    This paper describes a radioisotope production cyclotron which has been designed to minimize the dose to personnel during operation and maintenance. The design incorporates lessons learned from the operation of a CP42 cyclotron and has resulted in a reduction of the dose by a factor of more than 10. (author)

  12. Radioisotopic monitoring of esophageal motility in patients with achalasia cardiae after surgical treatment

    International Nuclear Information System (INIS)

    Tran Dinh Ha; Szilvasi, J.

    1994-01-01

    Results of the radioisotope esophageal motility studies in patients after surgical treatment of achalasia are presented. 28 patients were studied. In both group of the patients (after Belsey-Mark and modified Nissen antireflux surgical techniques) slightly delayed esophageal transit time was found. Mean transit time of the esophagus proved to be a useful practical parameter. This simple, noninvasive, physiological radioisotope technique is recommended for follow-up studies of patients after gastroesophageal surgery. (N.T.). 10 refs., 2 figs

  13. Particle-beam accelerators for radiotherapy and radioisotopes

    International Nuclear Information System (INIS)

    Boyd, T.J.; Crandall, K.R.; Hamm, R.W.

    1981-01-01

    The philosophy used in developing the new PIGMI technology was that the parameters chosen for physics research machines are not necessarily the right ones for a dedicated therapy or radioisotope machine. In particular, the beam current and energy can be optimized, and the design should emphasize minimum size, simplicity and reliability of operation, and economy in capital and operating costs. A major part of achieving these goals lay in raising the operating frequency and voltage gradient of the accelerator, which shrinks the diameter and length of the components. Several other technical innovations resulted in major system improvements. One of these is a radically new type of accelerator structure named the radio-frequency quadrupole (RFQ) accelerator. This allowed us to eliminate the large, complicated ion source used in previous ion accelerators, and to achieve a very high quality accelerated beam. Also, by using advanced permanent magnet materials to make the focusing elements, the system becomes much simpler. Other improvements have been made in all of the accelerator components and in the methods for operating them. These will be described, and design and costing information examples given for several possible therapy and radioisotope production machines

  14. Radioisotopes produced by neutron irradiation of food

    International Nuclear Information System (INIS)

    Albright, S.; Seviour, R.

    2016-01-01

    The use of neutrons for cargo interrogation has the potential to drastically improve threat detection. Previous research has focussed on the production of "2"4Na, based on the isotopes produced in pharmaceuticals and medical devices. For both the total activity and the ingestion dose we show that a variety of isotopes contribute and that "2"4Na is only dominant under certain conditions. The composition of the foods has a strong influence on the resulting activity and ingestion dose suggesting that the pharmaceuticals and medical devices considered initially are not a viable analogue for foodstuffs. There is an energy dependence to the isotopes produced due to the cross-sections of different reactions varying with neutron energy. We show that this results in different isotopes dominating the ingestion dose at different energies, which has not been considered in the previous literature. - Highlights: • We show that neutron interrogation of food can produce many radioisotopes. • We show a strong dependance between food and certain radioisotopes. • Some isotopes are shown to have an energy dependence. • Previous claims that 24Na is the main threat is shown to only apply in special cases.

  15. Reliability Issues in Stirling Radioisotope Power Systems

    Science.gov (United States)

    Schreiber, Jeffrey; Shah, Ashwin

    2005-01-01

    Stirling power conversion is a potential candidate for use in a Radioisotope Power System (RPS) for space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced requirement of radioactive material. Reliability of an RPS that utilizes Stirling power conversion technology is important in order to ascertain long term successful performance. Owing to long life time requirement (14 years), it is difficult to perform long-term tests that encompass all the uncertainties involved in the design variables of components and subsystems comprising the RPS. The requirement for uninterrupted performance reliability and related issues are discussed, and some of the critical areas of concern are identified. An overview of the current on-going efforts to understand component life, design variables at the component and system levels, and related sources and nature of uncertainties are also discussed. Current status of the 110 watt Stirling Radioisotope Generator (SRG110) reliability efforts is described. Additionally, an approach showing the use of past experience on other successfully used power systems to develop a reliability plan for the SRG110 design is outlined.

  16. Color doppler energy (CDE) : initial ten-months experience

    International Nuclear Information System (INIS)

    Ro, Young Jin; Son, Hyun Ju; Lee, Suck Hong; Kim, Byung Soo; Han, Kook Sang; Nam, SAng Hwa; Lee, Keum Seob; Shin Se Kwon

    1996-01-01

    Color Doppler imaging(CDI) has shortcomings, including random noise, aliasing, and angle dependence. To overcome these, a method using CD US, termed power doppler or Color Doppler Energy(CDE), has recently been introduced. The purpose of this study was to show the clinical usefulness of CDE. We retrospectively analyzed the CDI and CDE of 61 cases(20 renal pseudotumors, 8 musculoskeletal inflammations, 17 epididymitis or epididymo-orchitis, 3 varicoceles, 1 normal testis, 1 hepatocellualr carcinoma, 7 renal cell carcinoma, 1 renal angiomyolipoma, and 3 splenic varices). CDI and CDE scans were obtained at the same region with constant scan plane. The color gain was increased until noise first became perceptible, and scans were always obtained in such a way that the maximum amount of vascularity was shown. Thereafter, the vascularity, vascular displacement, and the vascular relationship between CDI and CDE were compared. In 17 of 20 cases of pseudotumor in the kidney, normal vascularity was identified in CDI and CDE, but was more cleary visible in CDE. In three cases, there was no visible vascularity in CDI, but normal vascularity in CDE. In eight cases of musculoskeletal inflammation and 17 cases of epididymitis with or without orchitis, the vascularity was increased due to hyperemia, which was more prominently seen in CDE than in CDI. In three varicoceles, CDE appeared to be better in demonstrating low velocity flow. In one patient who was suspected of having acute testicular torsion, CDE was helpful in excluding this suspicion. In one case of hepatocellualr carcinoma, seven cases of renal cell carcinoma, one case of renal angiomyolipoma, and three cases of splenic varices, CDE was better than CDI in showing the vascularity, vascular relationship, and vascular displacement

  17. Preferred skin color enhancement for photographic color reproduction

    Science.gov (United States)

    Zeng, Huanzhao; Luo, Ronnier

    2011-01-01

    Skin tones are the most important colors among the memory color category. Reproducing skin colors pleasingly is an important factor in photographic color reproduction. Moving skin colors toward their preferred skin color center improves the color preference of skin color reproduction. Several methods to morph skin colors to a smaller preferred skin color region has been reported in the past. In this paper, a new approach is proposed to further improve the result of skin color enhancement. An ellipsoid skin color model is applied to compute skin color probabilities for skin color detection and to determine a weight for skin color adjustment. Preferred skin color centers determined through psychophysical experiments were applied for color adjustment. Preferred skin color centers for dark, medium, and light skin colors are applied to adjust skin colors differently. Skin colors are morphed toward their preferred color centers. A special processing is applied to avoid contrast loss in highlight. A 3-D interpolation method is applied to fix a potential contouring problem and to improve color processing efficiency. An psychophysical experiment validates that the method of preferred skin color enhancement effectively identifies skin colors, improves the skin color preference, and does not objectionably affect preferred skin colors in original images.

  18. Color 3D electronic imaging of the surface of the human body

    Science.gov (United States)

    Rioux, Marc

    1994-10-01

    The NRC laboratories have developed a laser scanning technique to digitize shapes and colors in registration. The technique, known as synchronized scanning, is capable of digitizing topography as small as the relief of a bare finger tip, showing a clear picture of the skin structure (essentially a clean fingerprint without distortion), as well as the shape and size of body components such as hands, face, and feet, and the full body of one or more subjects simultaneously. The laser scanner uses a RGB laser, coupled to an optical fiber, which is projected in the field of view. The 3D color measurements are made by optical triangulation to a resolution of 10 micrometers for finger tip scans and a resolution of 1 mm for whole body scans. Experimental results are presented and discussed. Potential applications of this technology in the field of identification and inspection of humans include face recognition, finger, foot and teeth print identification, and 3D mugshots that can be rapidly broadcast through satellite communication. One of the unique properties of this technology is that absolute measurements, not only appearance and relative position of features, can be used for identification purposes.

  19. Nimbus 7 Coastal Zone Color Scanner (CZCS). Level 1 data product users' guide

    Science.gov (United States)

    Williams, S. P.; Szajna, E. F.; Hovis, W. A.

    1985-01-01

    The coastal zone color scanner (CZCS) is a scanning multispectral radiometer designed specifically for the remote sensing of Ocean Color parameters from an Earth orbiting space platform. A technical manual which is intended for users of NIMBUS 7 CZCS Level 1 data products is presented. It contains information needed by investigators and data processing personnel to operate on the data using digital computers and related equipment.

  20. Medical research with radioisotopes in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Belcher, E H [Post-graduate Medical School, Hammersmith, London (United Kingdom)

    1961-07-15

    An important program of research into the nature and causes of congenital haemolytic anaemias, notably the disease known as Mediterranean anaemia or Thalassaemia, which is a serious medical problem in the Mediterranean countries, is at present being carried out in the Department of Clinical Therapeutics of the University of Athens under a research contract awarded by the International Atomic Energy Agency. This program is concerned with diseases in which there is an inherited defect or abnormality in the production of haemoglobin, the iron-containing pigment of the red blood cells which is responsible for the carriage of oxygen in the blood. Two techniques have been widely used in the studies at the University of Athens. In the first of these, a radioisotope of iron, iron-59, is used to follow iron metabolism and haemoglobin production. Iron metabolism in the body is concerned largely with the synthesis and breakdown of haemoglobin, which consists of a protein, globin, linked to an iron containing substance, haeme. The second technique makes use of a radioisotope of chromium, chromium-51, to study the fate of the red cells in the blood. By performing simultaneous studies with iron- 59 and chromium-51, a detailed picture of haemoglobin synthesis and red cell production and destruction can be built up. Such investigations have been invaluable in establishing the characteristic patterns of different congenital haemolytic anaemias.