WorldWideScience

Sample records for radioguided surgery system

  1. Radioguided surgery with MIBI in brain tumors: on the subject of a case

    International Nuclear Information System (INIS)

    Martín Escuela, Juan Miguel

    2016-01-01

    Many efforts are directed towards better intraoperative detection and delimitation of brain tumors, in order to achieve better resection. A recent technique, implemented is radioguided surgery in which the tumor tissue is marked with a radiotracer (MIBI) and through the use of a probe and / or gamma camera to differentiate it from healthy brain tissue, in vivo, in the surgery room. : Evaluate the feasibility of radioguided surgery and optimize the procedures with the purpose of developing a clinical protocol for the reception of brain tumors. MATERIALS AND METHODS: A patient with a high grade glioma was submitted to MIBI, confirming that gamma camera facilitated the intraoperative detection of the tumor and indicated a small piece of residual tumor that was subsequently resected, Achieving total resection of the lesion. Conclusion: Radio-guided surgery with MIBI, showed, in this case, that it is a safe and reliable technique, not only for the detection and delimitation of brain tumors, but also for confirmation of presence or absence of residual tumor, facilitating total resection of the lesion.

  2. Clinical applications of gamma-detection probes - radioguided surgery

    International Nuclear Information System (INIS)

    Schneebaum, S.; Stadler, J.; Skornick, Y.

    1999-01-01

    Radioguided surgery (RGS) is a surgical technique that enables the surgeon to identify tissue ''marked'' by a radionuclide before surgery, based on the tissue characteristics, the radioactive tracer and its carrying molecule, or the affinity of both. Thus, yet another tool has been added to the inspection and palpation traditionally used by the surgeon. Current clinical applications of radioguided surgery are: radioimmunoguided surgery (RIGS) for colon cancer, sentinel-node mapping for malignant melanoma (which has become state-of-the-art), sentinel-node mapping for breast, vulvar and penile cancer, and detection of parathyroid adenoma and bone tumour (such as osteid osteoma). Although the same gamma-detecting probe (GDP) may be used for all these applications, the carrier substance and the radionuclide differ. MoAb and peptides are used for RIGS, sulphur colloid for sentinel-node mapping, iodine-125 for RIGS, technetium-99m for sentinel node, parathyroid and bone. The mode of injection also differs, but there are some common principles of gamma-guided surgery. RIGS enables the surgeon to corroborate tumour existence, find occult metastases, and assess the margins of resection; this may result in a change on the surgical plan. Sentinel lymph-node (SLN) scintigraphy for melanoma guides the surgeon to find the involved lymph nodes for lymph-node dissection. SLN for breast cancer is being investigated with promising results. This procedure has also changed the outlook of lymph-node pathology by giving the pathologist designated tissue samples for more comprehensive examination. Gamma-guided surgery will result in more accurate and less unnecessary surgery, better pathology and, hopefully, in better patient survival. (orig.)

  3. Radioguided Surgery for Localization of Nonpalpable Breast Lesions A Mini-Review

    DEFF Research Database (Denmark)

    Langhans, Linnea; Klausen, Thomas Levin; Tvedskov, Tove Filtenborg

    2016-01-01

    by ultrasound a small titanium seed containing typically 1-10 MBq of radioactive iodine-125 is placed in the centre of the nonpalpable breast lesion. During the operation the seed is located with a hand-held gamma probe. To date, only few cohort studies exist on the feasibility of RSL, and the method has only...... of patients with insufficient resection margin. These patients require a reoperation. New methods in the field of radioguided surgery (RGS) have been developed including radioguided occult lesion localization (ROLL) and radioactive seed localization (RSL). Especially RSL is a very promising technique. Guided...

  4. Sentinel lymph node detection through radioguided surgery in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita Andrade Leal de; Santos, Adriana de Morais; Soares, Livia de Almeida; Santos, Antonio Ricardo dos; Barros, Idna de Carvalho; Abreu, Everardo Leal de; Cruz Filho, Alexandre Jorge Gomes da; Abreu, Joao Batista de; Vieira, Sabas Carlos [Universidade Estadual do Piaui, Teresina, PI (Brazil); Centro Federal de Educacao Tecnologica do Piaui (CEFET-PI), Teresina, PI (Brazil); Faculdade Sao Gabriel, PI (Brazil); Hospital Sao Marcos, PI (Brazil); Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2008-12-15

    Biopsy of the sentinel lymphnode (SLNB), the first lymphnode to receive lymphatic drainage from the primary tumor, accurately predicts the axillary lymph node status and, when negative, obviates the need for axillary lymphadenectomy (AL). The aim of this study was, to verify the SLN localization in breast cancer through preoperative lymphoscintigraphy and intraoperative gamma-probe, as well as to demonstrate the benefits of such techniques in preventing complications of AL. Medical records of 228 patients with breast carcinoma, who were underwent SLN localization and, radioguided surgery, from March 2005 to December 2007 were analyzed retrospectively. Data regarding age, tumor characteristic, breast involved, type of surgery, radiopharmaceutical drainage pattern, axillary assessment (SLNB or AL) and number of lymph nodes dissected were collected. It was ascertained that radioguided surgery is a selective method of axillary assessment in breast cancer, which makes this technique a safe alternative to radical assessment of total dissection of axillary lymph nodes and its subsequent complications. (author)

  5. Sentinel lymph node detection through radioguided surgery in patients with breast cancer

    International Nuclear Information System (INIS)

    Abreu, Benedita Andrade Leal de; Santos, Adriana de Morais; Soares, Livia de Almeida; Santos, Antonio Ricardo dos; Barros, Idna de Carvalho; Abreu, Everardo Leal de; Cruz Filho, Alexandre Jorge Gomes da; Abreu, Joao Batista de; Vieira, Sabas Carlos

    2008-01-01

    Biopsy of the sentinel lymphnode (SLNB), the first lymphnode to receive lymphatic drainage from the primary tumor, accurately predicts the axillary lymph node status and, when negative, obviates the need for axillary lymphadenectomy (AL). The aim of this study was, to verify the SLN localization in breast cancer through preoperative lymphoscintigraphy and intraoperative gamma-probe, as well as to demonstrate the benefits of such techniques in preventing complications of AL. Medical records of 228 patients with breast carcinoma, who were underwent SLN localization and, radioguided surgery, from March 2005 to December 2007 were analyzed retrospectively. Data regarding age, tumor characteristic, breast involved, type of surgery, radiopharmaceutical drainage pattern, axillary assessment (SLNB or AL) and number of lymph nodes dissected were collected. It was ascertained that radioguided surgery is a selective method of axillary assessment in breast cancer, which makes this technique a safe alternative to radical assessment of total dissection of axillary lymph nodes and its subsequent complications. (author)

  6. A γ detecting probe developed for radioguided surgery and its primary using for animal experiment

    International Nuclear Information System (INIS)

    Wei Haipeng, Lin Yingwu; Gong Peirong; Yang Zhirong; Qiu Shi

    2003-01-01

    A new γ detecting probe device was described, which was used in radioguided surgery (RGS) for detecting tumor and its micrometastasis. The concrete scheme for this system was given in this paper and its performance was also evaluate. The animal experimental results showed that the γ detecting probe has excellent location resolution, and its collimator is practical

  7. Surgery with radioguided location of a liver metastasis of melanoma choroid: case report

    International Nuclear Information System (INIS)

    Moreno, Marcelo; Miranda, Mario Henrique Furlanetto

    2015-01-01

    Introduction: The use of radioguided occult lesion localization prior to surgical excision is increasing, mainly due to the development of new probes and the use of PET-CT. Case report: A 70-year-old male who presented with a metastatic lesion in his liver from a choroidal melanoma. This was located using PET-CT and subsequently located with a low-energy intraoperative gamma probe during the laparotomy. Conclusion: The present case shows that it is possible to excise a hepatic metastasis utilizing the principles of radioguided surgery, even in centers without access to high energy probes. (author)

  8. Radio-guided surgery in differentiated thyroid cancer: report of four cases

    International Nuclear Information System (INIS)

    Kallel, F.; Hamza, F.; Charfeddine, S.; Guermazi, F.; Ghorbel, A.

    2009-01-01

    Radio-guided surgery is a technique using the ability of a tumour tissue to uptake a radiopharmaceutical, in order, to facilitate its location with an intraoperative gamma probe. This technique was first used in the detection of recurrent thyroid cancer. We present our experience in this indication in four cases which were followed in our department. (authors)

  9. Radio-guided thoracoscopic surgery (RGTS) of small pulmonary nodules.

    Science.gov (United States)

    Ambrogi, Marcello Carlo; Melfi, Franca; Zirafa, Carmelina; Lucchi, Marco; De Liperi, Annalisa; Mariani, Giuliano; Fanucchi, Olivia; Mussi, Alfredo

    2012-04-01

    The demand for adequate tissue sampling to determine individual tumor behavior is increasing the number of lung nodule resections, even when the diagnosis is already recognized. Video-assisted thoracic surgery (VATS) is the procedure of choice for diagnosis and treatment of small pulmonary nodules. Difficulties in localizing smaller and deeper nodules have been approached with different techniques. Herein we report our 13-years' experience with radio-guided thoracoscopic resection. Patients with pulmonary nodules smaller than 1 cm and/or deeper than 1 cm, below the visceral pleura, underwent computed tomography (CT)-guided injection of a solution, composed of 0.2 ml (99)Tc-labeled human serum albumin microspheres and 0.1 ml nonionic contrast, into the nodule. During the VATS procedure, an 11-mm-diameter collimated probe connected to a gamma ray detector was introduced to scan the lung surface. The area of major radioactivity, which matched with the area of the nodule, was resected. From 1997 to 2009, 573 patients underwent thoracoscopic resection of small pulmonary nodules, 211 with the radio-guided technique. There were 159 men and 52 women, with an average age of 60.6 years (range = 12-83). The mean duration of the surgical procedure was 41 min (range = 20-100). The procedure was successful in 208/211 cases. Three patients (0.5%) required conversion to a minithoracotomy. The mean length of pleural drainage and hospital stay was 2.3 and 3.7 days, respectively. Histological examination showed 98 benign lesions and 113 malignant lesions (61 metastases and 52 primary lung cancers). This study confirms that radio-guided localization of small pulmonary nodules is a feasible, safe, and quick procedure, with a high rate of success. The spread of the sentinel lymph node technique has increased the availability of technology required for RGTS.

  10. The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery

    International Nuclear Information System (INIS)

    Valdés Olmos, R. A.; Van Leeuwen, F. W. B.; Vidal-Sicart, S.; Giammarile, F.; Zaknun, J. J.; Mariani, G.

    2014-01-01

    The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In

  11. The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery.

    Science.gov (United States)

    Valdés Olmos, R A; Vidal-Sicart, S; Giammarile, F; Zaknun, J J; Van Leeuwen, F W; Mariani, G

    2014-06-01

    The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In

  12. Radioguided parathyroidectomy for tertiary hyperparathyroidism.

    Science.gov (United States)

    Somnay, Yash R; Weinlander, Eric; Alfhefdi, Amal; Schneider, David; Sippel, Rebecca S; Chen, Herbert

    2015-05-15

    Tertiary hyperparathyroidism (3HPT) is defined as the persistent hyperproduction of parathyroid hormone and resulting hypercalcemia after renal transplantation. Here, we examine the utility of radioguided parathyroidectomy (RGP) in patients with 3HPT. We reviewed a prospective surgery database containing 80 3HPT patients who underwent RGP from January 2001-July 2014 at our institution. We evaluated patient demographics, operative management, radioguided neoprobe utilization, and operative outcomes. Data are reported as mean ± standard error of the mean. The mean age of the patients was 52 ± 1 y, and 46% were male. A total of 69 patients had hyperplasia and received subtotal parathyroidectomy, whereas 5 patients had double adenomas and 6 patients had single adenomas. The average calcium level among 3HPT patients was 10.8 ± 0.1 mg/dL preoperatively and 8.7 ± 0.1 mg/dL postoperatively. In vivo radioguided counts normalized to background counts averaged 145 ± 4%, whereas ex vivo counts normalized to background counts averaged 69 ± 5%. All but one ex vivo count was >20%. Ectopically located glands were successfully localized in 38 patients using the gamma probe. Ex vivo percentage did not correlate with parathyroid gland weight, preoperative parathyroid hormone, or preoperative calcium. Our radioguided approach achieved normocalcemia in 96% of 3HPT patients undergoing RGP; two patients developed recurrent disease. In this series, all enlarged parathyroid glands were localized and resected using the gamma probe. Thus, RGP reliably localizes adenomatous, hyperplastic, and ectopically located glands in patients with 3HPT, resulting in high cure rate after resection. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications.

    Science.gov (United States)

    Tsuchimochi, Makoto; Sakahara, Harumi; Hayama, Kazuhide; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 mm. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (99mTc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56 +/- 0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  14. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimochi, Makoto; Hayama, Kazuhide [Department of Oral and Maxillofacial Radiology, The Nippon Dental University School of Dentistry at Niigata, 1-8 Hamaura-cho, 951-8580, Niigata (Japan); Sakahara, Harumi [Department of Radiology, Hamamatsu University School of Medicine, Hamamatsu (Japan); Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi [Acrorad Co. Ltd., Tokyo (Japan); Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar [Integrated Detector and Electronics A.S (IDE AS), Hovik (Norway)

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ({sup 99m}Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56{+-}0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and

  15. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    International Nuclear Information System (INIS)

    Tsuchimochi, Makoto; Hayama, Kazuhide; Sakahara, Harumi; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-01-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ( 99m Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56±0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  16. Comparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery.

    Science.gov (United States)

    Chapman, Gregg J; Povoski, Stephen P; Hall, Nathan C; Murrey, Douglas A; Lee, Robert; Martin, Edward W

    2014-09-13

    Intraoperative in situ identification of (18)F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal (18)F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal (18)F-FDG-avid tissue sites during (18)F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal (18)F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.

  17. Radioguided surgery of primary hyperparathyroidism in a population with a high prevalence of thyroid pathology

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Talavera, Paloma [University Hospital of Valladolid, Department of Nuclear Medicine, Valladolid (Spain); Gonzalez, Carmen; Gomez, Alberto [University Hospital of Salamanca, Department of Surgery, Salamanca (Spain); Garcia-Talavera, Jose Ramon; Martin, Esther; Martin, Mariano [University Hospital of Salamanca, Department of Nuclear Medicine, Salamanca (Spain)

    2010-11-15

    Patients with concomitant thyroid pathology are usually excluded from minimally invasive radioguided parathyroidectomy (MIRP). We assessed the value in these patients of the gamma probe, alone or in combination with other techniques, in MIRP and unilateral or bilateral approaches. We evaluated its performance in association with intraoperative determination of intact parathyroid hormone (ioPTHi) and preoperative {sup 99m}Tc-MIBI dual phase scintigraphy. Included in the study were 87 patients with a diagnosis of primary hyperparathyroidism who underwent radioguided surgery. They were divided into two groups depending on the presence of concomitant thyroid pathology (TP group, 33 patients) or absence of concomitant thyroid pathology (NTP group, 54 patients). In the TP group, ioPTHi achieved the highest accuracy (90.9%), followed by the gamma probe (81.8%) and scintigraphy (69.7%). In the NTP group, the probe (94.4%) performed better than ioPTH and scintigraphy (both 85.2%). In the TP group, scintigraphy in combination with the gamma probe had a success rate of 90.9%, and 94% in combination with ioPTHi. The three techniques are applied together had a success rate of 97%. For all patients undergoing MIRP, the probe alone worked well, irrespective of the presence or absence of concomitant thyroid pathology. Patients with concomitant thyroid pathology should not be a priori excluded from a MIRP, as long as other adjuvant techniques (scintigraphy or ioPTHi) are used in conjunction with the gamma probe. In these patients, the probe can also be helpful in unilateral or bilateral surgery. (orig.)

  18. Radioguided surgery of primary hyperparathyroidism in a population with a high prevalence of thyroid pathology

    International Nuclear Information System (INIS)

    Garcia-Talavera, Paloma; Gonzalez, Carmen; Gomez, Alberto; Garcia-Talavera, Jose Ramon; Martin, Esther; Martin, Mariano

    2010-01-01

    Patients with concomitant thyroid pathology are usually excluded from minimally invasive radioguided parathyroidectomy (MIRP). We assessed the value in these patients of the gamma probe, alone or in combination with other techniques, in MIRP and unilateral or bilateral approaches. We evaluated its performance in association with intraoperative determination of intact parathyroid hormone (ioPTHi) and preoperative 99m Tc-MIBI dual phase scintigraphy. Included in the study were 87 patients with a diagnosis of primary hyperparathyroidism who underwent radioguided surgery. They were divided into two groups depending on the presence of concomitant thyroid pathology (TP group, 33 patients) or absence of concomitant thyroid pathology (NTP group, 54 patients). In the TP group, ioPTHi achieved the highest accuracy (90.9%), followed by the gamma probe (81.8%) and scintigraphy (69.7%). In the NTP group, the probe (94.4%) performed better than ioPTH and scintigraphy (both 85.2%). In the TP group, scintigraphy in combination with the gamma probe had a success rate of 90.9%, and 94% in combination with ioPTHi. The three techniques are applied together had a success rate of 97%. For all patients undergoing MIRP, the probe alone worked well, irrespective of the presence or absence of concomitant thyroid pathology. Patients with concomitant thyroid pathology should not be a priori excluded from a MIRP, as long as other adjuvant techniques (scintigraphy or ioPTHi) are used in conjunction with the gamma probe. In these patients, the probe can also be helpful in unilateral or bilateral surgery. (orig.)

  19. Radioguided breast surgery for occult lesion localization – correlation between two methods

    Directory of Open Access Journals (Sweden)

    Gutfilen Bianca

    2008-08-01

    Full Text Available Abstract Background The detection of sub-clinical breast lesions has increased with screening mammography. Biopsy techniques can offer precision and agility in its execution, as well as patient comfort. This trial compares radioguided occult lesion localization (ROLL and wire-guided localization (WL of breast lesions. We investigate if a procedure at the ambulatorial level (ROLL could lead to a better aesthetic result and less postoperative pain. In addition, we intend to demonstrate the efficacy of radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions and correlate radiological and histopathological findings. Methods One hundred and twenty patients were randomized into two groups (59 WL and 61 ROLL. The patients were requested to score the cosmetic appearance of their breast after surgery, and a numerical rating scale was used to measure pain on the first postoperative day. Clearance margins were considered at ≥ 10 mm for invasive cancer, ≥ 5 mm for ductal carcinoma in situ, and ≥ 1 mm for benign disease. Patients were subsequently treated according to the definitive histological result. When appropriate, different statistical tests were used in order to test the significance between the two groups, considering a P value Results WL and ROLL located all the occult breast lesions successfully. In the ROLL group, the specimen volume was smaller and there were more cases with clear margins (P Conclusion ROLL is an effective method for the excision of non-palpable breast lesions. It enables more careful planning of the cutaneous incision, leading to better aesthetic results, less postoperative symptoms, and smaller volumes of excised tissue.

  20. Radio-guided surgery for removal of a giant parathyroid cyst related to hyperthyroidism

    International Nuclear Information System (INIS)

    Fuentes Valdes, Edelberto; Escarpanter Gonzalez, Julio C; Lopez Diaz, Adlin; Alfonso Trujillo, Yiovanni; Infante Amoros, Adalberto; Dominguez lvarez, Carlos A; Palau San Pedro, Aley

    2009-01-01

    Among present advances of surgical treatment of hyperthyroidism is the preoperative localization of hyper-functioning glands by preoperative and intraoperative scan, this later one by a special gamma probe. By the other hand, parathyroid cysts are rare; may be of functioning type or not, as well as the findings of 99mTc-MIBI, and the intraoperative use of gamma probe to assess all the possible sites where could be hyperproductive glands of parathyroid hormone. We describe features of management, safety, and administration of radiological agent during the immediate preoperative period, as well as use of gamma probe during intervention. Evolution over follow-up is reported. This case represents the third patient operated on from hyperthyroidism by radio-guided surgery in our center, which introduced this technique in our country. (Author)

  1. Surgery with radioguided location of a liver metastasis of melanoma choroid: case report; Cirurgia com localizacao radioguiada de uma metastase hepatica de melanoma de coroide: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Marcelo; Miranda, Mario Henrique Furlanetto, E-mail: mmoreno@unochapeco.edu.br, E-mail: mirandamario@unochapeco.edu.br [Universidade Comunitaria da Regiao de Chapeco (UNOCHAPECO), SC (Brazil)

    2015-04-15

    Introduction: The use of radioguided occult lesion localization prior to surgical excision is increasing, mainly due to the development of new probes and the use of PET-CT. Case report: A 70-year-old male who presented with a metastatic lesion in his liver from a choroidal melanoma. This was located using PET-CT and subsequently located with a low-energy intraoperative gamma probe during the laparotomy. Conclusion: The present case shows that it is possible to excise a hepatic metastasis utilizing the principles of radioguided surgery, even in centers without access to high energy probes. (author)

  2. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  3. New applications of radio guided surgery in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Chojniak, Rubens [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Image], e-mail: almirgvb@yahoo.com.br; Lima, Eduardo Nobrega Pereira [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Nuclear Medicine

    2009-07-01

    Objective: To report oncological cases (excluding those related to breast cancer) for which radioguided surgery has been used in combination with the Radioguided Occult Lesion Localization technique. Introduction: Radioguided surgery enables a surgeon to identify lesions or tissues that have been preoperatively marked with radioactive substances. The Radioguided Occult Lesion Localization technique has been widely used to identify the sentinel lymph node and occult lesions in patients with breast cancer. However, few studies have reported the use of this technique for non-breast cancer pathologies. Methodology: In all cases, injection of Technetium-99m sulfur colloid was performed, directly inside or near by the suspicious lesion, guided by ultrasound or computed tomography, up to 36 hours prior to the surgical procedure. Intraoperative lesion detection was carried out using a gamma-probe. Results: We report five oncology cases in which preoperative markings of the lesions were carried out using the Radioguided Occult Lesion Localization technique. The patients presented with the following: recurrence of renal cell carcinoma, cervical recurrence of papillary carcinoma of the thyroid, recurrence of retroperitoneal sarcoma, lesions of the popliteal fossa, and recurrence of rhabdomyosarcoma of a thigh. In each case, the lesions that were marked preoperatively were ultimately successfully excised. Conclusions: Radioguided surgery has proven to be a safe and effective alternative for the management of oncology patients. The Radioguided Occult Lesion Localization technique can be useful in selected cases where suspect lesions may be difficult to identify intraoperatively, due to their dimensions or anatomical location. The procedure allows for more conservative excisions and reduces the surgery-related morbidity. (author)

  4. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  5. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control.

    Science.gov (United States)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-09-18

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  6. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control

    International Nuclear Information System (INIS)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-01-01

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  7. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Kulig, J; Szybinski, P; Mikolajczak, R; Pach, D; Sowa-Staszczak, A; Fröss-Baron, K; Huszno, B

    2007-10-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.

  8. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Kulig, J.; Szybinski, P.; Mikolajczak, R.; Pach, D.; Sowa-Staszczak, A.; Froess-Baron, K.; Huszno, B.

    2007-01-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue ''marked'' by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [ 99m Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [ 99m Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [ 99m Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [ 99m Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology. (orig.)

  9. Association of Parathyroid Gland Biopsy Excision Technique With Ex Vivo Radiation Counts During Radioguided Parathyroid Surgery.

    Science.gov (United States)

    Hinson, Andrew M; Lawson, Bradley R; Franco, Aime T; Stack, Brendan C

    2017-06-01

    Parathyroid biopsy represents a means for normal and hyperfunctional glands to be distinguished intraoperatively. However, no data exist to guide surgeons regarding how much of a parathyroid gland must be biopsied to satisfy the 20% rule. To quantify the relative proportion of a hyperfunctional parathyroid gland that must be evaluated with the gamma probe to satisfy the 20% rule. A retrospective review of surgical data for 24 consecutive patients (16 women, 18 men; mean [SD] age, 66.6 [10] years; range, 51-83 years) who underwent surgery for primary hyperparathyroidism between May and October, 2015, in a tertieary academic medical center. Extirpated parathyroid glands were sectioned into parallel or pie-shaped biopsies and evaluated ex vivo with a gamma probe to determine what percentage of a hyperfunctional gland must be sampled to meet the Norman 20% rule. The hypothesis was formulated during data collection. In total, 253 ex vivo biopsy specimens were obtained from 33 surgically removed parathyroid glands. Parathyroid biopsies satisfied the 20% rule with an accuracy that depended on the relative proportion of the parent gland represented: half or more (96.6%; 95% CI, 91.7%-100.0%), a quarter to one-half (87.0%; 95% CI, 79.3%-94.7%), less than a quarter (63.6%; 95% CI, 54.5%-72.8%). When less than a quarter of the gland was removed, pie-shaped biopsies were more likely to satisfy the 20% rule compared with parallel biopsies of the same weight (78.4% vs 56.2%; absolute difference, 22.2%; 95% CI, 4.7%-39.7%). Unless half of a parathyroid gland is biopsied during radioguided parathyroidectomy, the 20% rule cannot reliably rule out the presence of a hyperfunctional parathyroid lesion. Pie-shaped biopsies originating from the center of the gland are associated with a lower rate of false-negative results compared with peripheral biopsies of similar size. Pie-shaped biopsies and biopsy of half or more of each nonexcised parathyroid gland for ex vivo counts may increase

  10. Use of {sup 99m}Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature

    Energy Technology Data Exchange (ETDEWEB)

    Denmeade, Kristie A [Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia); Constable, Chris [Brain and Mind Research Institute, University of Sydney, New South Wales (Australia); Reed, Warren M [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, New South Wales (Australia); Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia)

    2013-06-15

    The use of technetium-99m 2-methoxyisobutyl isonitrile ({sup 99m}Tc MIBI) for assistance in minimally invasive radioguided surgery (MIRS) is growing in popularity as a safe, effective, and proficient technique used for parathyroidectomy in primary hyperparathyroidism (PHPT) treatment. Previously, the preferred treatment for PHPT was bilateral neck exploration (BNE), a very invasive, costly, and lengthy procedure. However, as a large majority (80–85% of cases of PHPT) are attributed to a single parathyroid adenoma (PA), a simpler more direct technique such as MIRS is a far better option. The following article is an exploration of the current literature concerning varied protocols utilizing {sup 99m}Tc MIBI for assistance in MIRS for patients undergoing treatment of PHPT. This technique boasts many advantageous outcomes for patients suffering from PHPT. These include a reduction in cost, operating time, and patient recovery; less evidence of post-surgical hypocalcaemia, less pain, and complications; superior cosmetic results; same-day discharge; and the possibility of local anaesthesia which is particularly beneficial in elderly patients. Better outcomes for patients with deep or ectopic PAs, reduced intra-operative complications, and improved cosmetic outcomes for patients who have previously undergone thyroid and/or parathyroid surgery are also advantageous. Of the literature reviewed it was also found that no patients suffered any major surgical complications such as laryngeal nerve palsy or permanent hypoparathyroidism using {sup 99m}Tc MIBI for assistance in MIRS.

  11. Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    International Nuclear Information System (INIS)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia; Al-Nahhas, Adil; Boni, Giuseppe; Mariani, Giuliano; Pelizzo, Maria R.

    2006-01-01

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of 99m Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or 99m Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session 99m Tc-pertechnetate/ 99m Tc-sestamibi planar subtraction scintigraphy, followed by 99m Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of 99m Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) 99m Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p 99m Tc-sestamibi SPECT is more accurate in predicting the intraoperative measurements with the gamma probe. In this respect, a preoperative 99m Tc-sestamibi SPECT acquisition should be recommended for better selection of PHPT patients in whom

  12. Development of voltage sensitivity preamplifier to application in radioguided surgical probe

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da; Rela, Paulo Roberto; Hamada, Margarida Mizue

    2005-01-01

    The methods of nuclear medicine are increasing used to complement standard diagnostic examinations. Some of these are radioguided detection of the sentinel lymph node (SN) and the radioguided localization of occult lesions. The SN technique is used in a small-size breast carcinoma and involves the identification, removal and immediate histological examination. Specifically, particles of colloidal human serum albumin are labelled with low activities of 99m Tc and are inoculated into the breast lesion or close in the case of SN biopsy. Subsequently, a hand-held gamma-ray detecting probe with reduced dimensions is used to locate the lesion or the SN as a hot spot and guide its surgical removal. Many techniques can be used for gamma-ray probes development. Gamma photons can be either directly detected via high atomic numbers semiconductors detectors or indirect detection, as scintillator crystal converts gamma photons into light photons. In all of them, the preamplifier is used as close as possible to the detector for obtaining a good energy resolution and due to the necessary small probe dimension, the preamplifier must have reduced size. The commercial preamplifiers are not small enough to be assembled inside the probe. It was developed a not usually preamplifier configuration for high-resolution spectroscopy energy, adequate in size to be set up in gamma-ray probes. This tension preamplifier can be split between the gamma-ray probe and the read out unit. Due to this configuration the effective size required inside the probe was reduced. The results and the probe assembling are showed in this work. (author)

  13. Radioguided surgery for breast cancer- preliminary experience in Piaui, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita; Melo, Nayana; Vieira, Sabas; Abreu, Evandro; Abreu, Joao Batista de Abreu; Padua Filho, Antonio de [Centro Bionuclear de Diagnostico, Teresina, PI (Brazil); Universidade Estadual do Piaui, Teresina, PI (Brazil); Universidade Federal do Piaui, Teresina, PI (Brazil); Hospital Sao Marcos, Teresina, PI (Brazil); E-mail: bionuclear@uol.com.br

    2005-10-15

    Intraoperatory detection and excision of sentinel lymph node (SLN), radio guided occult lesion localization (ROLL) and lesional resection, or a combination of these two procedures at one time in a same patient (SNOLL), are techniques that represent, at the moment, a significant advance in breast cancer surgery, procedures in clinical practice being established, as can be seen from the medical literature, as well as in this institution. Thirty one patients with breast cancer were initially treated with the aid of radio guided surgery. Of those, 20 patients were submitted to sentinel lymph node biopsy, six have undergone only ROLL and five were submitted to a combination of the two techniques. (author)

  14. Radioguided surgery for breast cancer- preliminary experience in Piaui, Brazil

    International Nuclear Information System (INIS)

    Abreu, Benedita; Melo, Nayana; Vieira, Sabas; Abreu, Evandro; Abreu, Joao Batista de Abreu; Padua Filho, Antonio de

    2005-01-01

    Intraoperatory detection and excision of sentinel lymph node (SLN), radio guided occult lesion localization (ROLL) and lesional resection, or a combination of these two procedures at one time in a same patient (SNOLL), are techniques that represent, at the moment, a significant advance in breast cancer surgery, procedures in clinical practice being established, as can be seen from the medical literature, as well as in this institution. Thirty one patients with breast cancer were initially treated with the aid of radio guided surgery. Of those, 20 patients were submitted to sentinel lymph node biopsy, six have undergone only ROLL and five were submitted to a combination of the two techniques. (author)

  15. Clinical value of detection of intrathoracic metastatic lymph nodes with radioguided technique in patients with non-small cell lung carcinoma

    International Nuclear Information System (INIS)

    Lu Ming; Hu Yongxiao

    2008-01-01

    Objective: To study the possible clinical feasibility of intraoperative detection of metastatic lymph node with radioguided technique after labeling with 99m Tc-MIBI in patients with non-small cell lung carcinoma. Methods: Gamma-detecting probe was used intra-operatively to examine the radioactivity of lungs, regional and mediastinal nodes in 30 patients with non-small cell lung carcinoma after intravenous injection of 99m Tc-MIBI (740MBq) 30 minutes before operation for radio-labeling of the nodes. Postoperatively, the radiologically positive but conventionally pathologically negative as well as all the other nodes judged to be negative with conventional standard (altogether 201 groups) were all meticulously examined with serial sections and immunohistologic staining for detection of the presence of micro-metastasis. Results: Altogether 41 groups of nodes specimens were radiologically positive (over twofolds of normal radio-activity measured with γ probe), of which conventional pathological examination revealed metastasis in 32 groups. The remaining 9 groups of specimens were examined further with serial sections and IHC studies and micro-metastasis was found in 3 of them. Thus, the sensitivity of the radioguided technique was 100%, specificity 96.9% and accuracy rate 97.42%. In the remaining 192 radiologically negative groups of lymph nodes studied, no false negative cases (i. e. micrometastasis positive) were demonstrated. Conclusion: The radio-guided technique is very sensitive (100%), highly specific and accurate (98.9%), and 97.4% respectively), without false negativity demonstrated. Its practical clinical application seems to be feasible. (authors)

  16. Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures

    International Nuclear Information System (INIS)

    Povoski, Stephen P.; Martin, Edward W.; Sarikaya, Ismet; Hall, Nathan C.; Knopp, Michael V.; White, William C.; Marsh, Steven G.; Hinkle, George H.

    2008-01-01

    The purpose of the current study was to comprehensively evaluate occupational radiation exposure to all intraoperative and perioperative personnel involved in radioguided surgical procedures utilizing 18 F-fluorodeoxyglucose ( 18 F-FDG). Radiation exposure to surgeon, anesthetist, scrub technologist, circulating nurse, preoperative nurse, and postoperative nurse, using aluminum oxide dosimeters read by optically stimulated luminescence technology, was evaluated during ten actual radioguided surgical procedures involving administration of 18 F-FDG. Mean patient dosage of 18 F-FDG was 699 ± 181 MBq (range 451-984). Mean time from 18 F-FDG injection to initial exposure of personnel to the patient was shortest for the preoperative nurse (75 ± 63 min, range 0-182) followed by the circulating nurse, anesthetist, scrub technologist, surgeon, and postoperative nurse. Mean total time of exposure of the personnel to the patient was longest for the anesthetist (250 ± 128 min, range 69-492) followed by the circulating nurse, scrub technologist, surgeon, postoperative nurse, and preoperative nurse. Largest deep dose equivalent per case was received by the surgeon (164 ± 135 μSv, range 10-580) followed by the anesthetist, scrub technologist, postoperative nurse, circulating nurse, and preoperative nurse. Largest deep dose equivalent per hour of exposure was received by the preoperative nurse (83 ± 134 μSv/h, range 0-400) followed by the surgeon, anesthetist, postoperative nurse, scrub technologist, and circulating nurse. On a per case basis, occupational radiation exposure to intraoperative and perioperative personnel involved in 18 F-FDG radioguided surgical procedures is relatively small. Development of guidelines for monitoring occupational radiation exposure in 18 F-FDG cases will provide reassurance and afford a safe work environment for such personnel. (orig.)

  17. Incremental value of combined 99MTc tetrofosmin parathyroid scintigraphy, rapid intra operative PTH assays and minimally invasive radio-guided surgery (MIRS) in optimizing parathyroidectomies

    International Nuclear Information System (INIS)

    Padma, S.; Kumar, S.; Babu, T.; Kumar, H.; Nair, V.; Nair, G.K.

    2004-01-01

    Objective: Aim of our study was to evaluate incremental diagnostic value of 99mTc Tetrofosmin parathyroid SPECT (TPSPECT), rapid intra operative quick parathyroid hormone measurement (QPTH) combined with radio guidance provided by scintillation probe (Minimally Invasive Radio guided Surgery MIRS) in parathyroid surgeries. While TPSPECT is an established investigation in preoperative workup of hyperparathyroidism patients , MIRS is a relatively new concept in Indian subcontinent. Methods: 29 pts (M: F = 18: 11), age range 16- 65 yrs (mean 41+ 9 yrs) having clinical and biochemical hyperparathyroidism underwent TPSPECT between Jan 02 -04, using 20 mci IV 99mTc Tetrofosmin. Pts with familial hyperparathyroidism , previous nodular goiters and previous neck irradiation were excluded from study. Scintigraphy comprised of immediate, delayed planar and SPECT imaging of neck and chest. Imagewise abnormal, persistent tracer uptake was considered positive for adenoma and diffuse uptake for hyperplasia. 26 pts underwent exploration (22 adenomas and 4 hyperplasias).18 pts had benefit of intraoperative QPTH. A select group (after Dec 2003) i.e. 9 pts got the assistance of radioguided probing. Peroperatively NM physician used cordless handheld gamma probe (Gamma Finder, World of Medicine, Germany) in neck and mediastinum to detect parathyroid adenoma / hyperplasias. A five fold increase in radioactive counts perceived by probe when compared to background was considered positive for parathyroid adenoma / hyperplasia. If PTH levels fell from baseline by at least 50%, the surgery was concluded as complete. Results: In all 22 pts suspected to have primary hyperparathyroidism TPSPECT identified adenomas (100 % sensitivity). While planar imaging had a sensitivity of 90.1% (20/22 pts), SPECT identified the adenoma in all pts. Interestingly only 3/22 pts had ectopic glands while 5 had more than one adenomas. The most commonly involved gland was left inferior. In secondary

  18. Radio-fluoro guided surgery in high grade gliomas

    International Nuclear Information System (INIS)

    Lopez Piloto, Orestes; Salva Camano, Silvia; Gonzalez Gonzalez, Justo; Cruz Hernandez, Tania Margarita; Martinez Suarez, Eduardo; Lopez Arbolay, Omar; Ardisana Santana, Ernesto

    2015-01-01

    The MIBI (99mTc MIBI, methoxyisobutylisonitrile, MIBI, or sestamibi): is a wide readiness to the rich flow of photons, which improves the detection of pathological uptake with gamma probe, these physical properties make of this radiotracer the election to radioguided surgery. The sodium fluorescein is a water-soluble organic coloring substance used in the exam of the sanguine glasses of the eye. We carried out the report of five cases diagnosed with brain tumor of high grade of malignancy, with the objective to demonstrated that use of Radio-Fluro-guided Surgery (RFGS) we can achieve gross total resections without bigger deficit, completing the inclusion and exclusion criteria. The technique of RFGS demonstrated utility in the gross total resection, diminishing the residual tumor, without increasing surgery complexity and surgical times. In our study doesn't evidence of adverse effects for the administration of the radiopharmaceuticals and fluorescein

  19. Apport de la biopsie radioguidée dans le diagnostic histopathologique des tumeurs de l'enfant: expérience de l'Hôpital d'Enfant de Rabat

    Science.gov (United States)

    El Ochi, Mohamed Réda; Bellarbi, Salma; Rouas, Lamiae; Lamalmi, Najat; Malihy, Abderrahmane; Alhamany, Zaitouna; Cherradi, Nadia

    2015-01-01

    La biopsie radioguidée constitue une alternative à la biopsie chirurgicale invasive et à la cytologie pour le diagnostic des tumeurs pédiatriques. L'intérêt de notre étude est d’évaluer la valeur diagnostique des biopsies radioguidées examinées au laboratoire d'anatomopathologie de l'hôpital d'Enfants de Rabat (HER). L’étude a porté sur 78 biopsies radioguidées recueillies dans notre laboratoire entre janvier 2008 et décembre 2011. l’âge moyen des patients était de 5 ans et 10 mois avec une prédominance masculine (65,4%). La tumeur était abdominale dans 80% des cas, thoracique dans 15% cas, thoracique et abdominale dans 2,5% et sacrée dans 1,2%. Les biopsies étaient écho-guidées dans 90% des cas et scannoguidées dans 10% des cas. Le diagnostic histopathologique était posé dans 89% des cas. L'immuno-histochimie a été indiquée dans 35% des cas. Les diagnostics les plus fréquents étaient: tumeurs neuroblastiques (42 cas), lymphomes non hodgkiniens (10 cas), rhabdomyosarcomes (6 cas), autres (sarcome d'Ewing, néphroblastomes, tumeur myofibroblastique inflammatoire, maladies de Hodgkin, leucémie aiguë, hépatoblastome et ostéosarcome). Dans notre série, la biopsie radioguidée a permis un diagnostic histopathologique certain dans 89% des cas. Elle nécessite une étroite collaboration entre clinicien, radiologue et anatomopathologiste pour discuter son indication, afin de diminuer le nombre de biopsies peu ou non représentatives. PMID:26587165

  20. Role of {sup 99m}Tc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia [Istituto Oncologico Veneto (IOV), Nuclear Medicine Service - PET Unit, ' S. Maria della Misericordia' Hospital, Rovigo (Italy); Al-Nahhas, Adil [Hammersmith Hospital, Department of Nuclear Medicine, London (United Kingdom); Boni, Giuseppe; Mariani, Giuliano [University of Pisa Medical School, Regional Center of Nuclear Medicine, Pisa (Italy); Pelizzo, Maria R. [University of Padova Medical School, Department of Special Surgery, Padova (Italy)

    2006-09-15

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of {sup 99m}Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or {sup 99m}Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session {sup 99m}Tc-pertechnetate/{sup 99m}Tc-sestamibi planar subtraction scintigraphy, followed by {sup 99m}Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of {sup 99m}Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) {sup 99m}Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p<0.01) but no correlation was found with planar scintigraphic data. Our preliminary data suggest that measurement of the P/B ratio by means of {sup 99m}Tc-sestamibi SPECT is more accurate in predicting the

  1. iROLL: does 3-D radioguided occult lesion localization improve surgical management in early-stage breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Bluemel, Christina; Kajdi, Georg W.; Schmid, Jan; Buck, Andreas K.; Herrmann, Ken [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Cramer, Andreas; Grossmann, Christoph; Grimminger, Hanns-Joerg [Missionsaerztliches Klinikum Wuerzburg, Department of Obstetrics and Gynecology, Wuerzburg (Germany); Malzahn, Uwe [University of Wuerzburg, Institute of Clinical Epidemiology and Biometry, Wuerzburg (Germany); Lamp, Nora [University of Wuerzburg, Institute of Pathology, Wuerzburg (Germany); Langen, Heinz-Jakob [Missionsaerztliches Klinikum Wuerzburg, Department of Radiology, Wuerzburg (Germany)

    2015-10-15

    To prospectively evaluate the feasibility of 3-D radioguided occult lesion localization (iROLL) and to compare iROLL with wire-guided localization (WGL) in patients with early-stage breast cancer undergoing breast-conserving surgery and sentinel lymph node biopsy (SLNB). WGL (standard procedure) and iROLL in combination with SLNB were performed in 31 women (mean age 65.1 ± 11.2 years) with early-stage breast cancer and clinically negative axillae. Patient comfort in respect of both methods was assessed using a ten point scale. SLNB and iROLL were guided by freehand SPECT (fhSPECT). The results of the novel 3-D image-based method were compared with those of WGL, ultrasound-based lesion localization, and histopathology. iROLL successfully detected the malignant primary and at least one sentinel lymph node in 97 % of patients. In a single patient (3 %), only iROLL, and not WGL, enabled lesion localization. The variability between fhSPECT and ultrasound-based depth localization of breast lesions was low (1.2 ± 1.4 mm). Clear margins were achieved in 81 % of the patients; however, precise prediction of clear histopathological surgical margins was not feasible using iROLL. Patients rated iROLL as less painful than WGL with a pain score 0.8 ± 1.2 points (p < 0.01) lower than the score for iROLL. iROLL is a well-tolerated and feasible technique for localizing early-stage breast cancer in the course of breast-conserving surgery, and is a suitable replacement for WGL. As a single image-based procedure for localization of breast lesions and sentinel nodes, iROLL may improve the entire surgical procedure. However, no advantages of the image-guided procedure were found with regard to prediction of complete tumour resection. (orig.)

  2. iROLL: does 3-D radioguided occult lesion localization improve surgical management in early-stage breast cancer?

    Science.gov (United States)

    Bluemel, Christina; Cramer, Andreas; Grossmann, Christoph; Kajdi, Georg W; Malzahn, Uwe; Lamp, Nora; Langen, Heinz-Jakob; Schmid, Jan; Buck, Andreas K; Grimminger, Hanns-Jörg; Herrmann, Ken

    2015-10-01

    To prospectively evaluate the feasibility of 3-D radioguided occult lesion localization (iROLL) and to compare iROLL with wire-guided localization (WGL) in patients with early-stage breast cancer undergoing breast-conserving surgery and sentinel lymph node biopsy (SLNB). WGL (standard procedure) and iROLL in combination with SLNB were performed in 31 women (mean age 65.1 ± 11.2 years) with early-stage breast cancer and clinically negative axillae. Patient comfort in respect of both methods was assessed using a ten point scale. SLNB and iROLL were guided by freehand SPECT (fhSPECT). The results of the novel 3-D image-based method were compared with those of WGL, ultrasound-based lesion localization, and histopathology. iROLL successfully detected the malignant primary and at least one sentinel lymph node in 97% of patients. In a single patient (3%), only iROLL, and not WGL, enabled lesion localization. The variability between fhSPECT and ultrasound-based depth localization of breast lesions was low (1.2 ± 1.4 mm). Clear margins were achieved in 81% of the patients; however, precise prediction of clear histopathological surgical margins was not feasible using iROLL. Patients rated iROLL as less painful than WGL with a pain score 0.8 ± 1.2 points (p localizing early-stage breast cancer in the course of breast-conserving surgery, and is a suitable replacement for WGL. As a single image-based procedure for localization of breast lesions and sentinel nodes, iROLL may improve the entire surgical procedure. However, no advantages of the image-guided procedure were found with regard to prediction of complete tumour resection.

  3. Novel technology of molecular radio-guidance for lymph node dissection in recurrent prostate cancer by PSMA-ligands.

    Science.gov (United States)

    Rauscher, Isabel; Horn, Thomas; Eiber, Matthias; Gschwend, Jürgen E; Maurer, Tobias

    2018-04-01

    Recently, prostate-specific membrane antigen-radioguided surgery (PSMA-RGS) has been introduced as a promising new and individual treatment concept in patients with localised recurrent prostate cancer (PC). In the following, we want to review our experience with PSMA-RGS in patients with localised biochemical recurrent PC. A non-systematic review of the literature was carried out with focus on technical and logistical aspects of PSMA-RGS. Furthermore, published data on intraoperative detection of metastatic lesions compared to preoperative PSMA-PET and postoperative histopathology, postoperative complications as well as oncological follow-up data are summarized. Finally, relevant aspects on prerequisites for PSMA-RGS, patient selection, and the potential benefit of additional salvage radiotherapy or potential future applications of robotic PSMA-RGS with drop-in γ-probes are discussed. First results show that PSMA-RGS is very sensitive and specific in tracking suspicious lesions intraoperatively. Prerequisite for patient selection and localisation of tumour recurrence is a positive Ga-HBED-CC PSMA positron-emission tomography (PET) scan with preferably only singular soft tissue or lymph node recurrence after primary treatment. Furthermore, PSMA-RGS has the potential to positively influence oncological outcome. PSMA-RGS seems to be of high value in patients with localised PC recurrence for exact localisation and resection of oftentimes small metastatic lesions using intraoperative and ex vivo γ-probe measurements. However, patient identification on the basis of Ga-HBED-CC-PSMA PET imaging as well as clinical parameters is crucial to obtain satisfactory results.

  4. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  5. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  6. Probe-guided surgery: metastases of a papillary thyroid carcinoma. Surgical Excision

    International Nuclear Information System (INIS)

    Kowadlo, A.R.; Zund, S.; Perez Irigoyen, C.

    2008-01-01

    A male patient with papillary thyroid cancer -follicular variety- is chosen to be presented. After thyroidectomy, lymphadenectomy and therapeutic dose of radioiodine treatments, cancer relapse was observed. After thyrotrophin suppressive therapy with l-thyroxine, a high serum thyroglobulin concentration was observed. The Ultrasonography (US) and Magnetic Resonance (MR) images showed visible node structures in the neck. This node structures were probably going to concentrate I-131 as seen in the fi rst whole body scan after therapeutic dose. Therefore a radio-guided surgery was planned as the best choice. (Institute Gustave Roussy protocol). A therapeutic dose of radioiodine (I-131) was given and up to the 4th day a whole body scan was performed. In the 5th day a gamma- probe-guided surgery was performed as well, and localized metastatic foci in the pretracheal region and under right recurrent laryngeal nerve. No other foci were identified ed with the probe at surgery. Forty eight hours after surgery a new whole-body scan was made again. The procedure was successful. The metastatic lesions were completely dissected. The last whole body scan showed that radioiodine concentration had disappeared at all. Forty fi ve days and three months after surgery under levothyroxine treatment, the serum thyroglobulin level concentration decrease to very low values. (authors) [es

  7. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    International Nuclear Information System (INIS)

    Scopinaro, F.; Capriotti, G.; Di Santo, G.; Capotondi, C.; Micarelli, A.; Massari, R.; Trotta, C.; Soluri, A.

    2006-01-01

    The diagnosis of diabetic foot osteomyelitis is often difficult. 99m Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm 2 FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. 99m Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot

  8. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capriotti, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Di Santo, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capotondi, C. [Unit of Radiology, S. Andrea Hospital, Rome (Italy); Micarelli, A. [Nuclear Medicine, Sulmona Hospital, Sulmona (AQ) (Italy); Massari, R. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Trotta, C. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Soluri, A. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy)]. E-mail: soluri@isib.cnr.it

    2006-12-20

    The diagnosis of diabetic foot osteomyelitis is often difficult. {sup 99m}Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm{sup 2} FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. {sup 99m}Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot.

  9. Radioguided surgery: First experiences with surgical gamma probe

    International Nuclear Information System (INIS)

    Vereb, M.; Bakala, J.

    2004-01-01

    Full text: Thanks to the International Atomic Energy Agency and co-operation of the Nuclear Regulatory Authority of the Slovak Republic - International and Public Relations Division, sentinel lymph node detection has been introduced in one of the regional hospitals in Slovakia. Surgical Gamma Probe, the equipment needed for this has been made available. IAEA first of all helped in organizing a workshop on Scintimammography, Sentinel Lymph Node Detection and Intra-Operative Surgical Probe in Breast Cancer, in April 2002. Education of specialists - surgeons, oncologists, and pathologists and of course radiologists helped them to better understand the subject visa-vis nuclear medicine techniques. We also started the sentinel node detection following the two-days protocol. A 57 years old female with newly detected breast carcinoma in right breast, with positive mammography was investigated. Axillary lymph nodes were not palpable. Tc-99m Nanocoll, with particles size ranging 4-100 nm, was administered, 75 MBq peritumorally + 75 MBq subdermally and a dynamic lymphoscintigraphy was acquired which showed migration of the radiotracer. Static views (after 120 min.) demonstrated 4 sentinel lymph nodes in the right axilla. No lymph node was seen in the internal mammary or left axillary region. Next day before operation about 2 ml of patten blue dye was injected around the tumor and breast was compressed for about 10 min. Identification of sentinel lymph node was done with the help of surgical gamma probe and blue tinting. We found 6 nodes, first two were not really sentinel, but they were blue. A breast conservation surgery with standard axillary lymphadenectomy was performed. Pathology revealed invasive ductal carcinoma. We understand the need to establish an algorithm of examination and treatment of patients with newly diagnosed breast carcinoma. This technology requires teamwork of surgeon, nuclear medicine physician and pathologist. Regarding radiation exposure which every

  10. Cirugía radioguiada para la extirpación de un quiste paratiroideo gigante con hiperparatiroidismo Radio-guided surgery for removal of a giant parathyroid cyst related to hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Edelberto Fuentes Valdés

    2009-04-01

    Full Text Available Entre los avances actuales del tratamiento quirúrgico del hiperparatiroidismo se encuentra la localización preoperatoria de la(s glándula(s hiperfuncionante(s mediante gammagrafía preoperatoria e intraoperatoria, esta última a través de una sonda gamma especial. Por otro lado, los quistes paratiroideos son raros; pueden ser funcionantes o no. Se describe un nuevo caso de quiste paratiroideo hiperfuncionante, así como los hallazgos de la gammagrafía con 99mTc-MIBI y el uso intraoperatorio de la sonda gamma para evaluar todos los sitios probables donde pudieran existir glándulas hiperproductoras de hormona paratiroidea. Se describen aspectos de la manipulación, seguridad y administración del radiofármaco en el período preoperatorio inmediato, así como la utilización de la sonda gamma durante la intervención. Se informa la evolución durante el seguimiento. Este caso representa el tercer paciente intervenido por hiperparatiroidismo mediante cirugía radioguiada en nuestro centro, institución en la que se introdujo esta técnica en el paísAmong present advances of surgical treatment of hyperthyroidism is the preoperative localization of hyper-functioning glands by preoperative and intraoperative scan, this later one by a special gamma probe. By the other hand, parathyroid cysts are rare; may be of functioning type or not, as well as the findings of 99mTc-MIBI, and the intraoperative use of gamma probe to assess all the possible sites where could be hyperproductive glands of parathyroid hormone. We describe features of management, safety, and administration of radiological agent during the immediate preoperative period, as well as use of gamma probe during intervention. Evolution over follow-up is reported. This case represents the third patient operated on from hyperthyroidism by radio-guided surgery in our center, which introduced this technique in our country.

  11. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  12. Radioguided sentinel node biopsy with 99mTc colloidal (Re) sulphide: Our experience

    International Nuclear Information System (INIS)

    Lago, G.; Alonso, O.; Aizen, B.; Juri, C.

    2004-01-01

    Full text: It has been demonstrated that nodal metastases from different solid tumors are not random events. Tumour spread within the regional draining basin has been shown to progress in an orderly fashion with first draining basin (sentinel node) most likely to have metastatic involvement. Thus, the sentinel node examination accurately reflects the histology of the remainder of the lymphatic basin. Sentinel node biopsy (SLB) with previous lymphatic mapping by means of radiocolloid lymphoscintraphy has been proposed by many authors as a routine method for staging the regional lymph nodes in patients with cutaneous melanoma and breast cancer. A positive SLB is found to carry high prognostic significance and identifies those patients who might benefit from early therapeutic lymph node dissection and adjuvant treatment. The aim of this retrospective study was to evaluate our experience with radioguided SLB in patients with different tumours. We studied 154 patients between 1998-2003, with clinically localized breast cancer (n=45), melanoma (n=82), cervix carcinoma (n=22) and penis carcinoma (n=5). Lymphoscintigraphy was performed 6-18 hours before surgery using a LFOV gamma camera equipped with a LEHR collimator. A dose of 111-185 MBq of 99mTc colloidal sulphide (Nanocis, Cis bio international, Gif-Sur-Yvette, France) was injected around the primary lesion (melanoma, breast cancer, and penis carcinoma) and into the four quadrants of the cervix (cervix carcinoma). All basins identified by lymphoscintigraphy were explored through incisions directed by the use of a gamma probe. Radioactivity (counts /sec) of the sentinel node(s) and the adjacent tissues was measured in-vivo and verified ex-vivo after removal. A signal to background ratio higher than 2 to 3 in-vivo and higher than 10 ex-vivo was considered significant. Blue dye mapping was performed in all cases of breast cancer but left at discretion of the surgeon for the remaining tumours. Serial sections of the

  13. Robotic systems in spine surgery.

    Science.gov (United States)

    Onen, Mehmet Resid; Naderi, Sait

    2014-01-01

    Surgical robotic systems have been available for almost twenty years. The first surgical robotic systems were designed as supportive systems for laparoscopic approaches in general surgery (the first procedure was a cholecystectomy in 1987). The da Vinci Robotic System is the most common system used for robotic surgery today. This system is widely used in urology, gynecology and other surgical disciplines, and recently there have been initial reports of its use in spine surgery, for transoral access and anterior approaches for lumbar inter-body fusion interventions. SpineAssist, which is widely used in spine surgery, and Renaissance Robotic Systems, which are considered the next generation of robotic systems, are now FDA approved. These robotic systems are designed for use as guidance systems in spine instrumentation, cement augmentations and biopsies. The aim is to increase surgical accuracy while reducing the intra-operative exposure to harmful radiation to the patient and operating team personnel during the intervention. We offer a review of the published literature related to the use of robotic systems in spine surgery and provide information on using robotic systems.

  14. Radio-guided localization of clinically occult breast lesions (ROLL): a DGH experience

    International Nuclear Information System (INIS)

    Thind, C.R.; Desmond, S.; Harris, O.; Nadeem, R.; Chagla, L.S.; Audisio, R.A.

    2005-01-01

    AIM: Wire-guided localization (WGL) of clinically occult breast lesions is a well established technique. The aim of this study was to evaluate radio-guided localization (ROLL) within the breast screening service of a district general hospital. METHOD: The study group comprised 70 women who underwent ROLL under US and stereotaxis. This required an injection of Technetium-labelled colloidal albumen into the impalpable breast lesion. The women then proceeded to theatre, where localization was achieved with the use of a gamma probe. The lesion was identified by the presence of a high signal, caused by the injected isotope. The results of 70 consecutive cases in which a breast lesion was localized using ROLL were compared with the results of the latest 70 WGLs. RESULTS: All 140 lesions were successfully localized. However, the change in technique from WGL to ROLL offered significant benefits to patients. CONCLUSION: Our study demonstrated that ROLL is a practical and reliable localization technique. It can be implemented in hospital units without using valuable gamma camera time. The cost compares well with WGL. There is an improved cosmetic outcome for patients, and the very small quantity of radioactivity used is safe for both patients and staff

  15. Feasibility of a wireless gammar probe in radioguided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Min; Kim, Jeong Ho; Park, Chan Jong; Joo, Koan Sik [Dept. of Physics, University of Myongji, Seoul (Korea, Republic of)

    2016-04-15

    Nuclear medicine is divided into two major domains: diagnosis and therapy. Nuclear medicine diagnostic procedures are used for determining and evaluating the physiological, chemical, endocrinal, and metabolic conditions of organs or tissues. Tumors can be diagnosed based on the images provided by the associated machinery; after diagnosis, sometimes these tumors can be surgically removed. Currently, to help guide the surgeon to the exact location of the tumor site, the use of intraoperative probes has steadily gained popularity. These probes allow the physician to locate the tumor on the basis of the higher uptake of the preoperatively injected radio pharmaceutical within the site, as compared to the surrounding tissue. Direct detection offers very good energy resolution, but the detection efficiency is low; on the other hand, indirect detection presents high efficiency and low energy resolution. For this reason, the use of both detectors is recommended for obtaining an accurate localization of the diagnostic and therapeutic fields. In the literature, there are several works that aim to develop a suitable probe that presents such characteristics (i.e., good resolution, high detection efficiency, as well as the capacity for miniaturization). In this study, a wireless gamma probe is designed for the detection of tumors of the tissue surface using a silicon photomultiplier (SiPM) and a cerium-doped gadolinium aluminum gallium garnet (Ce:GAGG) scintillator. Our experiments demonstrate the feasibility of wireless diagnostics, as well as the suitable energy resolution and spatial resolution. The system developed based on the results of this study is expected to perform intraoperative or diagnostic evaluations of residual lesions (or the absence thereof) and its quantitative distribution in the affected area, thus contributing to wireless diagnostics and screening systems.

  16. Comparison of Different Computer–Aided Surgery Systems in Skull Base Surgery

    OpenAIRE

    Ecke, U.; Luebben, B.; Maurer, J.; Boor, S.; Mann, W. J.

    2003-01-01

    Computer–aided surgery (CAS) based on high–resolution imaging techniques represents an important adjunct to precise intraoperative orientation when anatomical landmarks are distorted or missing. Several commercial systems, mostly based on optical or electromagnetic navigation principles, are on the market. This study investigated the application of EasyGuide®, VectorVision®, and InstaTrak® CAS systems in ENT surgery under practical and laboratory conditions. System accuracy, time required, ha...

  17. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  18. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control

    International Nuclear Information System (INIS)

    Machado, Rafael Henrique Szymanski; Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da

    2005-01-01

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99m Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  19. Implementation of an interactive liver surgery planning system

    Science.gov (United States)

    Wang, Luyao; Liu, Jingjing; Yuan, Rong; Gu, Shuguo; Yu, Long; Li, Zhitao; Li, Yanzhao; Li, Zhen; Xie, Qingguo; Hu, Daoyu

    2011-03-01

    Liver tumor, one of the most wide-spread diseases, has a very high mortality in China. To improve success rates of liver surgeries and life qualities of such patients, we implement an interactive liver surgery planning system based on contrastenhanced liver CT images. The system consists of five modules: pre-processing, segmentation, modeling, quantitative analysis and surgery simulation. The Graph Cuts method is utilized to automatically segment the liver based on an anatomical prior knowledge that liver is the biggest organ and has almost homogeneous gray value. The system supports users to build patient-specific liver segment and sub-segment models using interactive portal vein branch labeling, and to perform anatomical resection simulation. It also provides several tools to simulate atypical resection, including resection plane, sphere and curved surface. To match actual surgery resections well and simulate the process flexibly, we extend our work to develop a virtual scalpel model and simulate the scalpel movement in the hepatic tissue using multi-plane continuous resection. In addition, the quantitative analysis module makes it possible to assess the risk of a liver surgery. The preliminary results show that the system has the potential to offer an accurate 3D delineation of the liver anatomy, as well as the tumors' location in relation to vessels, and to facilitate liver resection surgeries. Furthermore, we are testing the system in a full-scale clinical trial.

  20. Systemic hypertension and non-cardiac surgery.

    Science.gov (United States)

    Misra, Satyajeet

    2017-09-01

    Primary systemic hypertension affects 10%-25% of individuals presenting for surgery and anaesthesia and constitutes an important cause of cancellation of elective surgeries. Much of the fear stems from the fact that hypertension may lead to adverse perioperative outcomes. Although long-standing hypertension increases the risk of stroke, renal dysfunction or major adverse cardiovascular events, the same is usually not seen in the perioperative period if blood pressure is <180/110 mmHg and this has been the overriding theme in the recent guidelines on perioperative blood pressure management. Newer concepts include isolated systolic hypertension and pulse pressure hypertension that are increasingly used to stratify risk. The aim of this review is to focus on the adult patient with chronic primary systemic hypertension posted for elective non-cardiac surgery and outline the perioperative concerns.

  1. Towards ubiquitous access of computer-assisted surgery systems.

    Science.gov (United States)

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  2. Systems workplace for endoscopic surgery.

    Science.gov (United States)

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  3. Application of da Vinci surgical robotic system in hepatobiliary surgery

    Directory of Open Access Journals (Sweden)

    Chen Jiahai

    2018-01-01

    Full Text Available The development of minimally invasive surgery has brought a revolutionary change to surgery techniques, and endoscopic surgical robots, especially Da Vinci robotic surgical system, has further broaden the scope of minimally invasive surgery, which has been applied in a variety of surgical fields including hepatobiliary surgery. Today, the application of Da Vinci surgical robot can cover most of the operations in hepatobiliary surgery which has proved to be safe and practical. What’s more, many clinical studies in recent years have showed that Da Vinci surgical system is superior to traditional laparoscopy. This paper summarize the advantage and disadvantage of Da Vinci surgical system, and outlines the current status of and future perspectives on the robot-assisted hepatobiliary surgery based on the cases reports in recent years of the application of Da Vinci surgical robot.

  4. [Hand surgery in the German DRG System 2007].

    Science.gov (United States)

    Franz, D; Windolf, J; Kaufmann, M; Siebert, C H; Roeder, N

    2007-05-01

    Hand surgery often needs only a short length of stay in hospital. Patients' comorbidity is low. Many hand surgery procedures do not need inpatient structures. Up until 2006 special procedures of hand surgery could not be coded. The DRG structure did not separate very complex and less complex operations. Specialized hospitals needed a proper case allocation of their patients within the G-DRG system. The DRG structure concerning hand surgery increased in version 2007 of the G-DRG system. The main parameter of DRG splitting is the complexity of the operation. Furthermore additional criteria such as more than one significant OR procedure, the patients' age, or special diagnoses influence case allocation. A special OPS code for complex cases treated with hand surgery was implemented. The changes in the DRG structure and the implementation of the new OPS code for complex cases establish a strong basis for the identification of different patient costs. Different case allocation leads to different economic impacts on departments of hand surgery. Whether the new OPS code becomes a DRG splitting parameter has to be calculated by the German DRG Institute for further DRG versions.

  5. Sentinel nodes in complex areas: innovating radioguided surgery

    NARCIS (Netherlands)

    Vermeeren, L.

    2011-01-01

    De eerste lymfeklier die in contact staat met een tumor noemt men de schildwachtklier. Door middel van een biopsie onderzoekt men deze klier om te kijken of sprake is van uitzaaiingen. Lenka Vermeeren beschrijft beeldvormende technieken om identificatie van schildwachtklieren te optimaliseren.

  6. Sentinel node detection in pre-operative axillary staging.

    Science.gov (United States)

    Trifirò, Giuseppe; Viale, Giuseppe; Gentilini, Oreste; Travaini, Laura Lavinia; Paganelli, Giovanni

    2004-06-01

    The concept of sentinel lymph node biopsy in breast cancer surgery is based on the fact that the tumour drains in a logical way via the lymphatic system, from the first to upper levels. Since axillary node dissection does not improve the prognosis of patients with breast cancer, sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 patients. Sentinel lymph node biopsy would represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. Subdermal or peritumoural injection of small aliquots (and very low activity) of radiotracer is preferred to intratumoural administration, and (99m)Tc-labelled colloids with most of the particles in the 100-200 nm size range would be ideal for radioguided sentinel node biopsy in breast cancer. The success rate of radioguidance in localising the sentinel lymph node in breast cancer surgery is about 97% in institutions where a high number of procedures are performed, and the success rate of lymphoscintigraphy in sentinel node detection is about 100%. The sentinel lymph node should be processed for intraoperative frozen section examination in its entirety, based on conventional histopathology and, when necessary, immune staining with anti-cytokeratin antibody. Nowadays, lymphoscintigraphy is a useful procedure in patients with different clinical evidence of breast cancer.

  7. RADIONUCLIDE INDICATION OF SENTINEL LYMPH NODES IN LARYNX AND LARYNGOPHARYNX CANCER

    Directory of Open Access Journals (Sweden)

    I. G. Sinilkin

    2014-01-01

    Full Text Available Aim: to determine the possibility of radionuclide methods in the identification of "sentinel" lymph node (SLN in larynx and laryngopharynx cancer patients.Material and methods: 17 patients with larynx and laryngopharynx cancer were included in research. In all patients for SLN visualization nanocolloid radiopharmaceutical was injection around tumor into mucous coat with the subsequent SPECT and radioguided study.Results: Sensitivity and specificity of SPECT and radioguided study for SLN identification were 100%. We found 22 SLN in 17 patients (from 1 to 2 per patient, on average 1.3. Most often SLN were located in the III level of a neck (lymph nodes around of carotid arteries – 12 SLN (54.5% and IIA level (under lower jaw lymph nodes – 6 (27.2%. One SLN (4.5% was localized in IV level and 3 nodes (13.6% in VI level. In 2 patients (11.8% metastasis in SLN were found. In these patients within 2 years cancer progressing was revealed. Fifteen patients (88.2% had no metastatic in SLN and had no progressing of a cancer.Conclusions: Sensitivity and specificity of SPECT and radioguided study for SLN identification are 100%. In patients with metastatic SLN radical surgery with lymph node dissection is helpful.

  8. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach

    Science.gov (United States)

    ORSARIA, PAOLO; CHIARAVALLOTI, AGOSTINO; FIORENTINI, ALESSANDRO; PISTOLESE, CHIARA; VANNI, GIANLUCA; VITTORIA GRANAI, ALESSANDRA; VARVARAS, DIMITRIOS; DANIELI, ROBERTA; SCHILLACI, ORAZIO; PETRELLA, GIUSEPPE; CLAUDIO BUONOMO, ORESTE

    2017-01-01

    Background: Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Patients and Methods: Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. Results: In all three cases, perioperative 18F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. Conclusion: This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. PMID:28064227

  9. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    Science.gov (United States)

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  10. [Orthopedic and trauma surgery in the German DRG System 2007].

    Science.gov (United States)

    Franz, D; Kaufmann, M; Siebert, C H; Windolf, J; Roeder, N

    2007-03-01

    The German Diagnosis-Related Groups (DRG) System was further developed into its 2007 version. For orthopedic and trauma surgery, significant changes were made in terms of the coding of diagnoses and medical procedures, as well as in the DRG structure itself. The German Societies for Trauma Surgery and for Orthopedics and Orthopedic Surgery (Deutsch Gesellschaft für Unfallchirurgie, DGU; and Deutsche Gesellschaft für Orthopädie und Orthopädische Chirurgie, DGOOC) once again cooperated constructively with the German DRG Institute InEK. Among other innovations, new International Classification of Diseases (ICD) codes for second-degree burns were implemented. Procedure codes for joint operations, endoprosthetic-surgery and spine surgery were restructured. Furthermore, a specific code for septic surgery was introduced in 2007. In addition, the DRG structure was improved. Case allocation of patients with more than one significant operation was established. Further DRG subdivisions were established according to the patients age and the Patient Clinical Complexity Level (PCCL). DRG developments for 2007 have improved appropriate case allocation, but once again increased the system's complexity. Clinicians need an ever growing amount of specific coding know-how. Still, further adjustments to the German DRG system are required to allow for a correct allocation of cases and funds.

  11. 99mTc-MIBI radio-guided minimally invasive parathyroidectomy: experience with patients with normal thyroids and nodular goiters.

    Science.gov (United States)

    Casara, Dario; Rubello, Domenico; Cauzzo, Cristina; Pelizzo, Maria Rosa

    2002-01-01

    The surgical approach to primary hyperparathyroidism (HPT) is changing. In patients with a high probability to be affected by a solitary parathyroid adenoma (PA), a unilateral neck exploration (UNE) or a minimally invasive radio-guided surgery (MIRS) using the intraoperative gamma probe (IGP) technique have recently been proposed. We investigated the role of IGP in a group of 84 patients with primary HPT who were homogeneously evaluated before surgery by a single-day imaging protocol including 99mTcO4/MIBI subtraction scan and neck ultrasound (US) and then operated on by the same surgical team. Quick parathyroid hormone (QPTH) was intraoperatively measured in all cases to confirm successful parathyroidectomy. In 70 patients with scan/US evidence of a single enlarged parathyroid gland (EPG) and with a normal thyroid gland, MIRS was planned. In the other 14 patients, the IGP technique was utilized during a standard bilateral neck exploration (BNE) because of the presence of concomitant nodular goiter (11 cases) or multiglandular disease (MGD) (3 cases). The IGP technique consisted of the following: (1) in the operating room, a low 99mTc-MIBI dose (37 MBq) was injected intravenously during anesthesia induction; (2) subsequently, the patient's neck was scanned with the probe by the surgeon to localize the cutaneous projection of the EPG; (3) in patients who underwent MIRS, the EPG was detected intraoperatively with the probe and removed through a small, 2 to 2.5 cm skin incision; (4) radioactivity was measured on the EPG both in vivo and ex vivo, the thyroid, the background and the parathyroid bed after EPG removal. In patients with concomitant nodular goiter, the radioactivity was also measured on the thyroid nodules. Surgical and pathologic findings were consistent with a single PA in 78 patients, parathyroid carcinoma in 2, and MGD in 4. MIRS was successfully performed in 67 of the 70 patients (97.7%) in whom this approach was planned. It must be pointed out that

  12. [Orthopedic and trauma surgery in the German DRG system. Recent developments].

    Science.gov (United States)

    Franz, D; Schemmann, F; Selter, D D; Wirtz, D C; Roeder, N; Siebert, H; Mahlke, L

    2012-07-01

    Orthopedics and trauma surgery are subject to continuous medical advancement. The correct and performance-based case allocation by German diagnosis-related groups (G-DRG) is a major challenge. This article analyzes and assesses current developments in orthopedics and trauma surgery in the areas of coding of diagnoses and medical procedures and the development of the 2012 G-DRG system. The relevant diagnoses, medical procedures and G-DRGs in the versions 2011 and 2012 were analyzed based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes were made for the International Classification of Diseases (ICD) coding of complex cases with medical complications, the procedure coding for spinal surgery and for hand and foot surgery. The G-DRG structures were modified for endoprosthetic surgery on ankle, shoulder and elbow joints. The definition of modular structured endoprostheses was clarified. The G-DRG system for orthopedic and trauma surgery appears to be largely consolidated. The current phase of the evolution of the G-DRG system is primarily aimed at developing most exact descriptions and definitions of the content and mutual delimitation of operation and procedures coding (OPS). This is an essential prerequisite for a correct and performance-based case allocation in the G-DRG system.

  13. Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial

    International Nuclear Information System (INIS)

    Ocal, Koray; Dag, Ahmet; Turkmenoglu, Ozgur; Yucel, Erdem; Gunay, Emel Ceylan; Duce, Meltem Nass

    2011-01-01

    Aim: this prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. Methods: a total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n 56) and wire-guided localization group (n 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. Results: there were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant. Conclusions: the present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins. (author)

  14. Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Ocal, Koray; Dag, Ahmet; Turkmenoglu, Ozgur; Yucel, Erdem [Mersin University (Turkey). Medical Faculty. Dept. of General Surgery; Gunay, Emel Ceylan [Mersin University (Turkey). Medical Faculty. Dept. of Nuclear Medicine; Duce, Meltem Nass [Mersin University (Turkey). Medical Faculty. Dept. of Radiology

    2011-07-01

    Aim: this prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. Methods: a total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n 56) and wire-guided localization group (n 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. Results: there were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant. Conclusions: the present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins. (author)

  15. A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

    Science.gov (United States)

    Xu, Xinghua; Zheng, Yi; Yao, Shujing; Sun, Guochen; Xu, Bainan; Chen, Xiaolei

    2018-01-01

    With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. A multimodal HMD system, mainly consisted of a HMD with two built-in displays, an action camera, and a laptop computer displaying reconstructed medical images, was developed to assist neuroendoscopic surgery. With this intensively integrated system, the neurosurgeon could freely switch between endoscopic image, three-dimensional (3D) reconstructed virtual endoscopy images, and surrounding environment images. Using a leap motion controller, the neurosurgeon could adjust or rotate the 3D virtual endoscopic images at a distance to better understand the positional relation between lesions and normal tissues at will. A total of 21 consecutive patients with ventricular system diseases underwent neuroendoscopic surgery with the aid of this system. All operations were accomplished successfully, and no system-related complications occurred. The HMD was comfortable to wear and easy to operate. Screen resolution of the HMD was high enough for the neurosurgeon to operate carefully. With the system, the neurosurgeon might get a better comprehension on lesions by freely switching among images of different modalities. The system had a steep learning curve, which meant a quick increment of skill with it. Compared with commercially available surgical assistant instruments, this system was relatively low-cost. The multimodal HMD system is feasible, practical, helpful, and relatively cost efficient in neuroendoscopic surgery.

  16. The University Münster Model Surgery System for Orthognathic Surgery. Part II -- KD-MMS.

    Science.gov (United States)

    Ehmer, Ulrike; Joos, Ulrich; Ziebura, Thomas; Flieger, Stefanie; Wiechmann, Dirk

    2013-01-04

    Model surgery is an integral part of the planning procedure in orthognathic surgery. Most concepts comprise cutting the dental cast off its socket. The standardized spacer plates of the KD-MMS provide for a non-destructive, reversible and reproducible means of maxillary and/or mandibular plaster cast separation. In the course of development of the system various articulator types were evaluated with regard to their capability to provide a means of realizing the concepts comprised of the KD-MMS. Special attention was dedicated to the ability to perform three-dimensional displacements without cutting of plaster casts. Various utilities were developed to facilitate maxillary displacement in accordance to the planning. Objectives of this development comprised the ability to implement the values established in the course of two-dimensional ceph planning. The system - KD-MMS comprises a set of hardware components as well as a defined procedure. Essential hardware components are red spacer and blue mounting plates. The blue mounting plates replace the standard yellow SAM mounting elements. The red spacers provide for a defined leeway of 8 mm for three-dimensional movements. The non-destructive approach of the KD-MMS makes it possible to conduct different model surgeries with the same plaster casts as well as to restore the initial, pre-surgical situation at any time. Thereby, surgical protocol generation and gnathologic splint construction are facilitated. The KD-MMS hardware components in conjunction with the defined procedures are capable of increasing efficiency and accuracy of model surgery and splint construction. In cases where different surgical approaches need to be evaluated in the course of model surgery, a significant reduction of chair time may be achieved.

  17. Historical contributions from the Harvard system to adult spine surgery.

    Science.gov (United States)

    Schoenfeld, Andrew J

    2011-10-15

    Literature review. To document the historical contributions from the Harvard Medical School system to the field of adult spine surgery. Despite the fact that significant contributions to the discipline of spinal surgery have derived from the Harvard system, no prior study documents the history of the Harvard spine services in a cohesive narrative. This historical perspective reviews the history of adult spine surgery within the Harvard system and outlines the significant contributions made by orthopedic and neurosurgical practitioners to the field. Literature reviews were performed from historical works, as well as scientific publications to fashion a cohesive review covering the history of spine surgery at Harvard from the early 19th century to the present. The development of the spine surgical services at the three main Harvard hospitals, and significant spine surgical personalities within the system, are discussed, including W. Jason Mixter, MD, Joseph S. Barr Sr., MD, and Marius N. Smith-Petersen, MD. Substantial developments that have arisen from the Harvard teaching hospitals include the recognition of disc herniation as the cause of radicular symptoms in the lower extremities, the description of lumbar discectomy as a surgical treatment for radicular pain, osteotomy for the correction of spinal deformity, and the first attempt to create a systematic algorithm capable of informing treatment for cervical spine trauma. Despite humble beginnings, the surgeons and scientists at Harvard have influenced nearly every facet of spine surgery over the course of the last two centuries.

  18. Current use of navigation system in ACL surgery: a historical review.

    Science.gov (United States)

    Zaffagnini, S; Urrizola, F; Signorelli, C; Grassi, A; Di Sarsina, T Roberti; Lucidi, G A; Marcheggiani Muccioli, G M; Bonanzinga, T; Marcacci, M

    2016-11-01

    The present review aims to analyse the available literature regarding the use of navigation systems in ACL reconstructive surgery underling the evolution during the years. A research of indexed scientific papers was performed on PubMed and Cochrane Library database. The research was performed in December 2015 with no publication year restriction. Only English-written papers and related to the terms ACL, NAVIGATION, CAOS and CAS were considered. Two reviewers independently selected only those manuscripts that presented at least the application of navigation system for ACL reconstructive surgery. One hundred and forty-six of 394 articles were finally selected. In this analysis, it was possible to review the main uses of navigation system in ACL surgery including tunnel positioning for primary and revision surgery and kinematic assessment of knee laxity before and after different surgical procedures. In the early years, until 2006, navigation system was mainly used to improve tunnel positioning, but since the last decade, this tool has been principally used for kinematics evaluation. Increased accuracy of tunnel placement was observed using navigation surgery, especially, regarding femoral, 42 of 146 articles used navigation to guide tunnel positioning. During the following years, 82 of 146 articles have used navigation system to evaluate intraoperative knee kinematic. In particular, the importance of controlling rotatory laxity to achieve better surgical outcomes has been underlined. Several applications have been described and despite the contribution of navigation systems, its potential uses and theoretical advantages, there are still controversies about its clinical benefit. The present papers summarize the most relevant studies that have used navigation system in ACL reconstruction. In particular, the analysis identified four main applications of the navigation systems during ACL reconstructive surgery have been identified: (1) technical assistance for tunnel

  19. Preliminary development of augmented reality systems for spinal surgery

    Science.gov (United States)

    Nguyen, Nhu Q.; Ramjist, Joel M.; Jivraj, Jamil; Jakubovic, Raphael; Deorajh, Ryan; Yang, Victor X. D.

    2017-02-01

    Surgical navigation has been more actively deployed in open spinal surgeries due to the need for improved precision during procedures. This is increasingly difficult in minimally invasive surgeries due to the lack of visual cues caused by smaller exposure sites, and increases a surgeon's dependence on their knowledge of anatomical landmarks as well as the CT or MRI images. The use of augmented reality (AR) systems and registration technologies in spinal surgeries could allow for improvements to techniques by overlaying a 3D reconstruction of patient anatomy in the surgeon's field of view, creating a mixed reality visualization. The AR system will be capable of projecting the 3D reconstruction onto a field and preliminary object tracking on a phantom. Dimensional accuracy of the mixed media will also be quantified to account for distortions in tracking.

  20. Application and development of non contact angle-wide viewing system in vitreous retinal surgery

    Directory of Open Access Journals (Sweden)

    Rong-Hua He

    2016-07-01

    Full Text Available Wide-angle viewing system as an important auxiliary device can clearly observe the whole fundus field of vision in vitreous surgery, which enable vitreoretinal surgery more efficient, safer and more effective. So it has very high application value in ophthalmologic operation. In this paper, we studied the development and application of wide-angle viewing system in vitreoretinal surgery in recent years, from which we summed up the advantage of non-contact wide-angle viewing system in clinical field, and pointed out the shortcomings. The ultimate goal is to make the non-contact wide-angle viewing system better applied in vitreous surgery.

  1. Computer control versus manual control of systemic hypertension during cardiac surgery

    NARCIS (Netherlands)

    Hoeksel, S.A.A.P.; Blom, J.A.; Jansen, J.R.C.; Maessen, J.G.; Schreuder, J.J.

    2001-01-01

    Keywords:Cardiac surgery;hypertension;closed-loop controlBackground: We recently demonstrated the feasibility of computer controlled infusion of vasoactive drugs for the control of systemic hypertension during cardiac surgery. The objective of the current study was to investigate the effects of

  2. Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies

    International Nuclear Information System (INIS)

    Vermeeren, L.; Valdes Olmos, R.A.; Vogel, W.V.; Sivro, F.; Hoefnagel, C.A.; Meinhardt, W.; Bex, A.; Poel, H.G. van der; Horenblas, S.

    2009-01-01

    Our aim was to assess the feasibility of intraoperative radioguidance with a portable gamma camera during laparoscopic sentinel node (SN) procedures in urological malignancies. We evaluated the use of the intraoperative portable gamma camera in 20 patients: 16 patients with prostate carcinoma (PCC), 2 patients with renal cell carcinoma (RC) and 2 patients with testicular cancer (TC). Intra/peritumoural injection of 99m Tc-nanocolloid ( 99m Tc) was followed by planar lymphoscintigraphy, SPECT/CT and marking of SN levels. Before laparoscopy a 125 I seed was fixed on the laparoscopic gamma probe as a pointer of SN seeking. The portable gamma camera was set to display the 99m Tc signal for SN localisation and the 125 I signal for SN seeking. Matching of these signals on screen indicated exact SN localisation, and consequently this SN was removed. The mean injected dose was 218 MBq in PCC, 228 MBq in RC and 88 MBq in TC. Pelvic SN were visualised in all PCC patients, with uncommonly located SN in seven patients. SN metastases were found in seven patients (one in a uncommonly located SN). Both RC patients and TC patients had para-aortic SN, which were all tumour free. A total of 59 SN were removed. The portable gamma camera enabled real-time SN display/identification in 18 patients (90%). The use of a portable gamma camera in combination with a laparoscopic gamma probe incorporates intraoperative real-time imaging with improved SN identification in urological malignancies. This procedure might also be useful for SN identification of other deep draining malignancies. (orig.)

  3. Travel patterns of cancer surgery patients in a regionalized system.

    Science.gov (United States)

    Smith, Andrew K; Shara, Nawar M; Zeymo, Alexander; Harris, Katherine; Estes, Randy; Johnson, Lynt B; Al-Refaie, Waddah B

    2015-11-01

    Regionalization of complex surgeries has increased patient travel distances possibly leaving a substantial burden on those at risk for poorer surgical outcomes. To date, little is known about travel patterns of cancer surgery patients in regionalized settings. To inform this issue, we sought to assess travel patterns of those undergoing a major cancer surgery within a regionalized system. We identified 4733 patients who underwent lung, esophageal, gastric, liver, pancreatic, and colorectal resections from 2002-2014 within a multihospital system in the Mid-Atlantic region of the United States. Patient age, race and/or ethnicity, and insurance status were extracted from electronic health records. We used Geographical Information System capabilities in R software to estimate travel distance and map patient addresses based on cancer surgery type and these characteristics. We used visual inspection, analysis of variance, and interaction analyses to assess the distribution of travel distances between patient populations. A total of 48.2% of patients were non-white, 49.9% were aged >65 y, and 54.9% had private insurance. Increased travel distance was associated with decreasing age and those undergoing pancreatic and esophageal resections. Also, black patients tend to travel shorter distances than other racial and/or ethnic groups. These maps offer a preliminary understanding into variations of geospatial travel patterns among patients receiving major cancer surgery in a Mid-Atlantic regionalized setting. Future research should focus on the impact of regionalization on timely delivery of surgical care and other quality metrics. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control; Deteccao e exerese de lesoes mamarias nao palpaveis orientadas por cirurgia radioguiada com injecao de ar para controle radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Rafael Henrique Szymanski [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia]. E-mail: raffaszymanski@yahoo.com.br; Oliveira, Afranio Coelho de [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho; Rocha, Augusto Cesar Peixoto [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Ginecologia e Obstetricia; Souza, Sergio Augusto Lopes de; Martins, Flavia Paiva Proenca [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil); Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia]. E-mail: lmirian@globo.com

    2005-11-15

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with {sup 99m}Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  5. Mathematical model of bone drilling for virtual surgery system

    Science.gov (United States)

    Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.

    2018-04-01

    The bone drilling is an essential part of surgeries in ENT and Dentistry. A proper training of drilling machine handling skills is impossible without proper modelling of the drilling process. Utilization of high precision methods like FEM is limited due to the requirement of 1000 Hz update rate for haptic feedback. The study presents a mathematical model of the drilling process that accounts the properties of materials, the geometry and the rotation rate of a burr to compute the removed material volume. The simplicity of the model allows for integrating it in the high-frequency haptic thread. The precision of the model is enough for a virtual surgery system targeted on the training of the basic surgery skills.

  6. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  7. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-12-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... system (SEDASYS) submitted by Ethicon Endo-Surgery Inc. (EES), the sponsor for SEDASYS. This meeting has...

  8. Extending topological surgery to natural processes and dynamical systems.

    Directory of Open Access Journals (Sweden)

    Stathis Antoniou

    Full Text Available Topological surgery is a mathematical technique used for creating new manifolds out of known ones. We observe that it occurs in natural phenomena where a sphere of dimension 0 or 1 is selected, forces are applied and the manifold in which they occur changes type. For example, 1-dimensional surgery happens during chromosomal crossover, DNA recombination and when cosmic magnetic lines reconnect, while 2-dimensional surgery happens in the formation of tornadoes, in the phenomenon of Falaco solitons, in drop coalescence and in the cell mitosis. Inspired by such phenomena, we introduce new theoretical concepts which enhance topological surgery with the observed forces and dynamics. To do this, we first extend the formal definition to a continuous process caused by local forces. Next, for modeling phenomena which do not happen on arcs or surfaces but are 2-dimensional or 3-dimensional, we fill in the interior space by defining the notion of solid topological surgery. We further introduce the notion of embedded surgery in S3 for modeling phenomena which involve more intrinsically the ambient space, such as the appearance of knotting in DNA and phenomena where the causes and effect of the process lies beyond the initial manifold, such as the formation of black holes. Finally, we connect these new theoretical concepts with a dynamical system and we present it as a model for both 2-dimensional 0-surgery and natural phenomena exhibiting a 'hole drilling' behavior. We hope that through this study, topology and dynamics of many natural phenomena, as well as topological surgery itself, will be better understood.

  9. Profitability analysis of a femtosecond laser system for cataract surgery using a fuzzy logic approach.

    Science.gov (United States)

    Trigueros, José Antonio; Piñero, David P; Ismail, Mahmoud M

    2016-01-01

    To define the financial and management conditions required to introduce a femtosecond laser system for cataract surgery in a clinic using a fuzzy logic approach. In the simulation performed in the current study, the costs associated to the acquisition and use of a commercially available femtosecond laser platform for cataract surgery (VICTUS, TECHNOLAS Perfect Vision GmbH, Bausch & Lomb, Munich, Germany) during a period of 5y were considered. A sensitivity analysis was performed considering such costs and the countable amortization of the system during this 5y period. Furthermore, a fuzzy logic analysis was used to obtain an estimation of the money income associated to each femtosecond laser-assisted cataract surgery (G). According to the sensitivity analysis, the femtosecond laser system under evaluation can be profitable if 1400 cataract surgeries are performed per year and if each surgery can be invoiced more than $500. In contrast, the fuzzy logic analysis confirmed that the patient had to pay more per surgery, between $661.8 and $667.4 per surgery, without considering the cost of the intraocular lens (IOL). A profitability of femtosecond laser systems for cataract surgery can be obtained after a detailed financial analysis, especially in those centers with large volumes of patients. The cost of the surgery for patients should be adapted to the real flow of patients with the ability of paying a reasonable range of cost.

  10. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  11. The university münster model surgery system for orthognathic surgery. Part II – KD-MMS

    Directory of Open Access Journals (Sweden)

    Ehmer Ulrike

    2013-01-01

    Full Text Available Abstract Background Model surgery is an integral part of the planning procedure in orthognathic surgery. Most concepts comprise cutting the dental cast off its socket. The standardized spacer plates of the KD-MMS provide for a non-destructive, reversible and reproducible means of maxillary and/or mandibular plaster cast separation. Methods In the course of development of the system various articulator types were evaluated with regard to their capability to provide a means of realizing the concepts comprised of the KD-MMS. Special attention was dedicated to the ability to perform three-dimensional displacements without cutting of plaster casts. Various utilities were developed to facilitate maxillary displacement in accordance to the planning. Objectives of this development comprised the ability to implement the values established in the course of two-dimensional ceph planning. Results The system - KD-MMS comprises a set of hardware components as well as a defined procedure. Essential hardware components are red spacer and blue mounting plates. The blue mounting plates replace the standard yellow SAM mounting elements. The red spacers provide for a defined leeway of 8 mm for three-dimensional movements. The non-destructive approach of the KD-MMS makes it possible to conduct different model surgeries with the same plaster casts as well as to restore the initial, pre-surgical situation at any time. Thereby, surgical protocol generation and gnathologic splint construction are facilitated. Conclusions The KD-MMS hardware components in conjunction with the defined procedures are capable of increasing efficiency and accuracy of model surgery and splint construction. In cases where different surgical approaches need to be evaluated in the course of model surgery, a significant reduction of chair time may be achieved.

  12. Surgery of the eloquent area using neuronavigation system

    International Nuclear Information System (INIS)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira

    2001-01-01

    The efficacy of a neuronavigation system for surgery of lesions near Broca's area (6 patients), skull base (5 patients), or paracentral sulcus (10 patients) was evaluated in this study. Using the neuronavigation system, three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus obtained by MRI and CT. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm. 3D reconstructed images were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. The precentral gyri identified by 3D reconstructed brain images coincided well with that identified by fMRI. In lesions near Broca's area, skull base, and paracentral sulcus, 3D reconstructed brain images were very useful for both the preoperative surgical simulation and the intraoperative neuronavigation to preserve the postoperative neurological function and to perform less invasive surgery. (author)

  13. Lymphoscintigraphy and radioguided surgery in cervical and vulvar malignant tumours

    International Nuclear Information System (INIS)

    Morales Guzman-Barron, Rosanna E.

    2006-01-01

    Objective: To validate a combined technique in the detection of sentinel nodes in early cervix and vulvar cancer patients. Material and Methods: Seventy patients, 24 to 63 years old (average 40 years), with cervical cancer stages IA2, IB1 and IIA, and fourteen patients, 28 to 80 years old (median 68 years) with vulval neoplasm, stage I and II, had sentinel node (SN) detection using lymphoscintigraphy and a gamma probe in the surgical room, after injection of Tc 99m dextran and patent blue dye. Sentinel nodes were seen between 20 and 135 minutes after injection, in cervical cancer, and between one and sixty minutes in vulvar neoplasms. In patients with cervical tumors, 99 sentinel nodes were localized in the obturator region, 28 were interiliac, nine were located in the external iliac region, three in the common iliac region and one was found in perineum. In patients with a vulvar neoplasm, all sentinel nodes were located in the superficial inguinal region. The detection rate was 98,8% for cervical cancer and 100% for vulvar neoplasms, with bilateral drainage in 46% and 29% respectively. Metastases were found in 10,4% (7/65) of IB1 stage cervical cancer patients (6 squamous cell carcinomas - non keratinizing: 5, keratinizing: 1 and one adenocarcionoma) and none in four patients with IA2 stage (with non keratinizing squamous cell carcinoma). The patients with IIA stage cervical cancer (keratinizing squamous cell carcinoma) had metastases in the SN. Three out of 14 patients with vulvar cancer showed metastases in the sentinel node. Two of them had epidermoid carcinoma and one, malignant melanoma. There were no metastases in non-sentinel nodes when sentinel nodes were negative for metastases, both in cervical or vulvar cancer. Conclusion: It is feasible to localize sentinel nodes in cervical and vulvar cancer, using a combined technique with Tc 99m Dextran and 'patent blue'. (author)

  14. Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Vermeeren, L.; Valdes Olmos, R.A.; Vogel, W.V.; Sivro, F.; Hoefnagel, C.A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Meinhardt, W.; Bex, A.; Poel, H.G. van der; Horenblas, S. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands)

    2009-07-15

    Our aim was to assess the feasibility of intraoperative radioguidance with a portable gamma camera during laparoscopic sentinel node (SN) procedures in urological malignancies. We evaluated the use of the intraoperative portable gamma camera in 20 patients: 16 patients with prostate carcinoma (PCC), 2 patients with renal cell carcinoma (RC) and 2 patients with testicular cancer (TC). Intra/peritumoural injection of {sup 99m}Tc-nanocolloid ({sup 99m}Tc) was followed by planar lymphoscintigraphy, SPECT/CT and marking of SN levels. Before laparoscopy a {sup 125}I seed was fixed on the laparoscopic gamma probe as a pointer of SN seeking. The portable gamma camera was set to display the {sup 99m}Tc signal for SN localisation and the {sup 125}I signal for SN seeking. Matching of these signals on screen indicated exact SN localisation, and consequently this SN was removed. The mean injected dose was 218 MBq in PCC, 228 MBq in RC and 88 MBq in TC. Pelvic SN were visualised in all PCC patients, with uncommonly located SN in seven patients. SN metastases were found in seven patients (one in a uncommonly located SN). Both RC patients and TC patients had para-aortic SN, which were all tumour free. A total of 59 SN were removed. The portable gamma camera enabled real-time SN display/identification in 18 patients (90%). The use of a portable gamma camera in combination with a laparoscopic gamma probe incorporates intraoperative real-time imaging with improved SN identification in urological malignancies. This procedure might also be useful for SN identification of other deep draining malignancies. (orig.)

  15. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

    Science.gov (United States)

    Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo

    2016-01-01

    The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (Psystem also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.

  16. [Financing of inpatient orthopaedics and trauma surgery in the 2011 G-DRG System].

    Science.gov (United States)

    Franz, D; Schemmann, F; Roeder, N; Siebert, H; Mahlke, L

    2011-09-01

    The German DRG system forms the basis for billing inpatient hospital services. It includes not only the case groups (G-DRGs), but also copayments. This paper analyses and evaluates the relevant developments of the 2011 G-DRG system for orthopaedics and traumatology from the medical and classificatory perspective. An analysis was performed of relevant diagnoses, medical procedures and G-DRGs in the 2010 and 2011 versions based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). A number of codes for surgical measures have been newly established or modified - above all in foot surgery, arthroscopic surgery and wound surgery. Here, the identification and the correct and performance-based mapping of complex and elaborate scenarios was again the focus of the restructuring of the G-DRG system. The G-DRG structure in orthopaedics and traumatology is changed, especially for polytraumata. The allocation of common cases with a standardized treatment pattern appears to be appropriate and the reimbursement adequate. For the less common and more complex cases the 2011 G-DRG system still shows need for further modification (e.g. polytraumata, joint replacement, spine surgery). The proper integration of the modified OPS classification for foot surgery to the appropriate G-DRGs will be essential to maintain the high quality of the reimbursement structure for the future.

  17. Optical imaging as an expansion of nuclear medicine: Cerenkov-based luminescence vs fluorescence-based luminescence

    International Nuclear Information System (INIS)

    Chin, Patrick T.K.; Welling, Mick M.; Leeuwen, Fijs W.B. van; Meskers, Stefan C.J.; Valdes Olmos, Renato A.; Tanke, Hans

    2013-01-01

    Integration of optical imaging technologies can further strengthen the field of radioguided surgery. Rather than using two separate chemical entities to achieve this extension, hybrid imaging agents can be used that contain both radionuclear and optical properties. Two types of such hybrid imaging agents are available: (1) hybrid imaging agents generated by Cerenkov luminescence imaging (CLI) of β-emitters and (2) hybrid imaging agents that contain both a radioactive moiety and a fluorescent dye. One major challenge clinicians are now facing is to determine the potential value of these approaches. With this tutorial review we intend to clarify the differences between the two approaches and highlight the clinical potential of hybrid imaging during image-guided surgery applications. (orig.)

  18. Optical imaging as an expansion of nuclear medicine: Cerenkov-based luminescence vs fluorescence-based luminescence

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Patrick T.K.; Welling, Mick M.; Leeuwen, Fijs W.B. van [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology, P.O. Box 9600, Leiden (Netherlands); Meskers, Stefan C.J. [Eindhoven University of Technology, Molecular Materials and Nanosystems, P.O. Box 513, Eindhoven (Netherlands); Valdes Olmos, Renato A. [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology, P.O. Box 9600, Leiden (Netherlands); Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Tanke, Hans [Leiden University Medical Center, Department of Molecular Cell Biology, P.O. Box 9600, Leiden (Netherlands)

    2013-08-15

    Integration of optical imaging technologies can further strengthen the field of radioguided surgery. Rather than using two separate chemical entities to achieve this extension, hybrid imaging agents can be used that contain both radionuclear and optical properties. Two types of such hybrid imaging agents are available: (1) hybrid imaging agents generated by Cerenkov luminescence imaging (CLI) of {beta}-emitters and (2) hybrid imaging agents that contain both a radioactive moiety and a fluorescent dye. One major challenge clinicians are now facing is to determine the potential value of these approaches. With this tutorial review we intend to clarify the differences between the two approaches and highlight the clinical potential of hybrid imaging during image-guided surgery applications. (orig.)

  19. Full Scale 3D Preoperative Planning System of the Ankle Joint Replacement Surgery with Multimedia System

    Directory of Open Access Journals (Sweden)

    Shuh-Ping Sun

    2014-05-01

    Full Text Available This study is intended to develop a computer-aided pre-surgical planning and simulating system in a multimedia environment for ankle joint replacement surgery. This system uses full-scale 3D reverse engineering techniques in design and development of the pre-surgical planning modules for ankle joint replacement surgery. This planning system not only develops the real-scale 3D image of the artificial ankle joint but also provides a detailed interior measurement of the ankle joint from various cutting planes. In this study, we apply the multimedia user interface to integrate different software functions into a surgical planning system with integrated functions. The functions include 3D model image acquisition, cutting, horizontal shifting and rotation of related bones (tibia and talus of the ankle joint in the predetermined time. For related bones of the ankle joint, it can also be used to design artificial ankle joints for adults in Taiwan. Those planning procedures can be recorded in this system for further research and investigation. Furthermore, since this system is a multimedia user interface, surgeons can use this system to plan and find a better and more efficient surgical approach before surgery. A database is available for this system to update and expand, which can provide different users with clinical cases as per their experience and learning.

  20. The da Vinci telerobotic surgical system: the virtual operative field and telepresence surgery.

    Science.gov (United States)

    Ballantyne, Garth H; Moll, Fred

    2003-12-01

    The United States Department of Defense developed the telepresence surgery concept to meet battlefield demands. The da Vinci telerobotic surgery system evolved from these efforts. In this article, the authors describe the components of the da Vinci system and explain how the surgeon sits at a computer console, views a three-dimensional virtual operative field, and performs the operation by controlling robotic arms that hold the stereoscopic video telescope and surgical instruments that simulate hand motions with seven degrees of freedom. The three-dimensional imaging and handlike motions of the system facilitate advanced minimally invasive thoracic, cardiac, and abdominal procedures. da Vinci has recently released a second generation of telerobots with four arms and will continue to meet the evolving challenges of surgery.

  1. Acute systemic inflammatory response after cardiac surgery in ...

    African Journals Online (AJOL)

    2017-09-03

    Sep 3, 2017 ... valve(s) replacement were enrolled, from a single center hospital, after informed consent was obtained. C-reactive ... Cite as: Gojo MKE, Prakaschandra R. Acute systemic inflammatory response after cardiac surgery in patients infected with human im- ..... Arroyo-Espliguero R, Avanzas P, Cosín-Sales J, Al-.

  2. [Orthopedic and trauma surgery in the German-DRG-System 2009].

    Science.gov (United States)

    Franz, D; Windolf, J; Siebert, C H; Roeder, N

    2009-01-01

    The German DRG-System was advanced into version 2009. For orthopedic and trauma surgery significant changes concerning coding of diagnoses, medical procedures and concerning the DRG-structure were made. Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2008 and 2009 based on the publications of the German DRG-institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2009 focussed on the development of DRG-structure, DRG-validation and codes for medical procedures to be used for very complex cases. The outcome of these changes for German hospitals may vary depending in the range of activities. G-DRG-System gained complexity again. High demands are made on correct and complete coding of complex orthopedic and trauma surgery cases. Quality of case-allocation within the G-DRG-System was improved. Nevertheless, further adjustments of the G-DRG-System especially for cases with severe injuries are necessary.

  3. A spatial registration method for navigation system combining O-arm with spinal surgery robot

    Science.gov (United States)

    Bai, H.; Song, G. L.; Zhao, Y. W.; Liu, X. Z.; Jiang, Y. X.

    2018-05-01

    The minimally invasive surgery in spinal surgery has become increasingly popular in recent years as it reduces the chances of complications during post-operation. However, the procedure of spinal surgery is complicated and the surgical vision of minimally invasive surgery is limited. In order to increase the quality of percutaneous pedicle screw placement, the O-arm that is a mobile intraoperative imaging system is used to assist surgery. The robot navigation system combined with O-arm is also increasing, with the extensive use of O-arm. One of the major problems in the surgical navigation system is to associate the patient space with the intra-operation image space. This study proposes a spatial registration method of spinal surgical robot navigation system, which uses the O-arm to scan a calibration phantom with metal calibration spheres. First, the metal artifacts were reduced in the CT slices and then the circles in the images based on the moments invariant could be identified. Further, the position of the calibration sphere in the image space was obtained. Moreover, the registration matrix is obtained based on the ICP algorithm. Finally, the position error is calculated to verify the feasibility and accuracy of the registration method.

  4. [Severity of disease scoring systems and mortality after non-cardiac surgery].

    Science.gov (United States)

    Reis, Pedro Videira; Sousa, Gabriela; Lopes, Ana Martins; Costa, Ana Vera; Santos, Alice; Abelha, Fernando José

    2018-04-05

    Mortality after surgery is frequent and severity of disease scoring systems are used for prediction. Our aim was to evaluate predictors for mortality after non-cardiac surgery. Adult patients admitted at our surgical intensive care unit between January 2006 and July 2013 was included. Univariate analysis was carried using Mann-Whitney, Chi-square or Fisher's exact test. Logistic regression was performed to assess independent factors with calculation of odds ratio and 95% confidence interval (95% CI). 4398 patients were included. Mortality was 1.4% in surgical intensive care unit and 7.4% during hospital stay. Independent predictors of mortality in surgical intensive care unit were APACHE II (OR=1.24); emergent surgery (OR=4.10), serum sodium (OR=1.06) and FiO 2 at admission (OR=14.31). Serum bicarbonate at admission (OR=0.89) was considered a protective factor. Independent predictors of hospital mortality were age (OR=1.02), APACHE II (OR=1.09), emergency surgery (OR=1.82), high-risk surgery (OR=1.61), FiO 2 at admission (OR=1.02), postoperative acute renal failure (OR=1.96), heart rate (OR=1.01) and serum sodium (OR=1.04). Dying patients had higher scores in severity of disease scoring systems and longer surgical intensive care unit stay. Some factors influenced both surgical intensive care unit and hospital mortality. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. AN EFFICIENT SELF-UPDATING FACE RECOGNITION SYSTEM FOR PLASTIC SURGERY FACE

    Directory of Open Access Journals (Sweden)

    A. Devi

    2016-08-01

    Full Text Available Facial recognition system is fundamental a computer application for the automatic identification of a person through a digitized image or a video source. The major cause for the overall poor performance is related to the transformations in appearance of the user based on the aspects akin to ageing, beard growth, sun-tan etc. In order to overcome the above drawback, Self-update process has been developed in which, the system learns the biometric attributes of the user every time the user interacts with the system and the information gets updated automatically. The procedures of Plastic surgery yield a skilled and endurable means of enhancing the facial appearance by means of correcting the anomalies in the feature and then treating the facial skin with the aim of getting a youthful look. When plastic surgery is performed on an individual, the features of the face undergo reconstruction either locally or globally. But, the changes which are introduced new by plastic surgery remain hard to get modeled by the available face recognition systems and they deteriorate the performances of the face recognition algorithm. Hence the Facial plastic surgery produces changes in the facial features to larger extent and thereby creates a significant challenge to the face recognition system. This work introduces a fresh Multimodal Biometric approach making use of novel approaches to boost the rate of recognition and security. The proposed method consists of various processes like Face segmentation using Active Appearance Model (AAM, Face Normalization using Kernel Density Estimate/ Point Distribution Model (KDE-PDM, Feature extraction using Local Gabor XOR Patterns (LGXP and Classification using Independent Component Analysis (ICA. Efficient techniques have been used in each phase of the FRAS in order to obtain improved results.

  6. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Science.gov (United States)

    2011-03-21

    ...] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition for Review... an advisory committee Ethicon Endo- Surgery Inc.'s (EES's), petition for review of the Agency's... Foreman, FDA, CDRH, to Ken Charak, Ethicon Endo-Surgery, Inc., containing the order denying approval of...

  7. [First experience in the thyroid and parathyroid surgery using the da Vinci® system].

    Science.gov (United States)

    Al Kadah, B; Siemer, S; Schick, B

    2014-01-01

    Endoscopic surgery for the treatment of thyroid and parathyroid pathologies is gaining increasing attention. The da Vinci® system has been already widely used in different fields of medicine including recently thyroid and parathyroid surgery. Herein we report our first experiences in endoscopic surgery of thyroid and parathyroid pathologies using the da Vinci® system. 8 patients presenting with struma nodosa in 6 cases and parathyroid adenomas in 2 cases have been treated using the da Vinci® system at the ENT department of Homburg/Saar University. The skin incision to introduce the instruments with the da Vinci® system were axilar or at the lateral segment of the clavicle. The neurovascular structures like inferior laryngeal nerve as well as the pathologies were clearly 3-dimensional visualized in all 8 cases. No paralysis of the vocal cord was observed. All patients had in histological examination a benign pathology. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci® system and offers an excellent, intraoperative, 3-dimensional visualization of the neurovascular structures. Additionally the da Vinci® system enables skin incisions within considerable distance from the thyroid and parathyroid gland. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Systemic and Topical Use of Tranexamic Acid in Spinal Surgery: A Systematic Review

    Science.gov (United States)

    Winter, Sebastian F.; Santaguida, Carlo; Wong, Jean; Fehlings, Michael G.

    2015-01-01

    Study Design Combination of narrative and systematic literature reviews. Objectives Massive perioperative blood loss in complex spinal surgery often requires blood transfusions and can negatively affect patient outcome. Systemic use of the antifibrinolytic agent tranexamic acid (TXA) has become widely used in the management of surgical bleeding. We review the clinical evidence for the use of intravenous TXA as a hemostatic agent in spinal surgery and discuss the emerging role for its complementary use as a topical agent to reduce perioperative blood loss from the surgical site. Through a systematic review of published and ongoing investigations on topical TXA for spinal surgery, we wish to make spine practitioners aware of this option and to suggest opportunities for further investigation in the field. Methods A narrative review of systemic TXA in spinal surgery and topical TXA in surgery was conducted. Furthermore, a systematic search (using PRISMA guidelines) of PubMed (MEDLINE), EMBASE, and Cochrane CENTRAL databases as well as World Health Organization International Clinical Trials Registry Platform, ClinicalTrials.gov (National Institutes of Health), and International Standard Randomized Controlled Trial Number registries was conducted to identify both published literature and ongoing clinical trials on topical TXA in spinal surgery. Results Of 1,631 preliminary search results, 2 published studies were included in the systematic review. Out of 285 ongoing clinical trials matching the search criteria, a total of 4 relevant studies were included and reviewed. Conclusion Intravenous TXA is established as an efficacious hemostatic agent in spinal surgery. Use of topical TXA in surgery suggests similar hemostatic efficacy and potentially improved safety as compared with intravenous TXA. For spinal surgery, the literature on topical TXA is sparse but promising, warranting further clinical investigation and consideration as a clinical option in cases with

  9. Haptic feedback designs in teleoperation systems for minimal invasive surgery

    NARCIS (Netherlands)

    Font, I.; Weiland, S.; Franken, M.; Steinbuch, M.; Rovers, A.F.

    2004-01-01

    One of the major shortcomings of state-of-the-art robotic systems for minimal invasive surgery is the lack of haptic feedback for the surgeon. In order to provide haptic information, sensors and actuators have to be added to the master and slave device. A control system should process the data and

  10. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery

    Directory of Open Access Journals (Sweden)

    Jones JJ

    2016-06-01

    Full Text Available Jason J Jones,1 Jeffrey Chu,2 Jacob Graham,2 Serge Zaluski,3 Guillermo Rocha4 1Jones Eye Clinic, Sioux City, IA, 2Quorum Consulting Inc., San Francisco, CA, USA; 3VISIS, Perpignan, France; 4Ocular Microsurgery & Laser Centre, Brandon, MB, Canada Purpose: The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Methods: Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. Results: The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%–12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France. Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Conclusion: Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity. Keywords: time and motion, provider impact, surgical throughput, IOL

  11. Screening for sporadic or familial medullary thyroid carcinoma. Scintiscan s and radio-immunotherapy

    International Nuclear Information System (INIS)

    Rhmer, V.; Murat, A.

    2000-01-01

    The screening for sporadic medullary thyroid carcinoma relies upon calcitoninemia level, basal or during pentagastrine stimulation test. MEN2 are associated with nearly the third of medullary thyroid carcinoma. In these cases, prognosis of thyroid carcinoma is mainly driven by the tumor status at the time of surgery. Up to date, diagnosis relies upon the genetic screening. Prophylactic thyroidectomy indication may take account of calcitoninemia. Most of the molecules that have been suggested for scintiscan lack of accuracy and large use cannot be recommended. Promising results have been obtained with monoclonal antibodies anti-CEA, particularly with dual targeting antiCEA antiDTPA. This last technique may also be used for radio-guided surgery. Its use for radio-immunotherapy is under investigation. (authors)

  12. [ENT medicine and head and neck surgery in the G-DRG system 2008].

    Science.gov (United States)

    Franz, D; Roeder, N; Hörmann, K; Alberty, J

    2008-09-01

    Further developments in the German DRG system have been incorporated into the 2008 version. For ENT medicine and head and neck surgery significant changes concerning coding of diagnoses, medical procedures and concerning the DRG-structure were made. Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2007 and 2008 based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2008 focussed on the development of DRG structure, DRG validation and codes for medical procedures. The outcome of these changes for German hospitals may vary depending on the range of activities. The G-DRG system has gained in complexity again. High demands are made on correct and complete coding of complex ENT and head and neck surgery cases. Quality of case allocation within the G-DRG system has been improved. For standard cases quality of case allocation is adequate. Nevertheless, further adjustments of the G-DRG system especially for cases with complex neck surgery are necessary.

  13. Innovations in robotic surgery.

    Science.gov (United States)

    Gettman, Matthew; Rivera, Marcelino

    2016-05-01

    Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.

  14. [Orthopedic and trauma surgery in the German DRG system 2008].

    Science.gov (United States)

    Franz, D; Kaufmann, M; Siebert, C H; Windolf, J; Roeder, N

    2008-04-01

    The German DRG (diagnosis-related groups) system has been modified and updated into version 2008. For orthopedic and trauma surgery significant changes concerning coding of diagnoses, medical procedures and the DRG structure were made. The modified version has been analyzed in order to ascertain whether the DRG system is suitably qualified to fulfill the demands of the reimbursement system or whether further improvements are necessary. Analysis of the severity of relevant side-effect diagnoses, medical procedures and G-DRGs in the versions 2007 and 2008 was carried out based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2008 focused on the development of DRG structure, DRG validation and codes for medical procedures. The outcome of these changes for German hospitals may vary depending on the range of activities. G-DRG system has become even more complex and the new regulations have also resulted in new problems associated with complications.. High demands are made on correct and complete coding of complex orthopedic and trauma surgery cases. Quality of case allocation within the G-DRG system has been improved. Nevertheless, further improvements of the G-DRG system are necessary, especially for cases with severe injuries.

  15. Development and application of stent-based image guided navigation system for oral and maxillofacial surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woo Jin; Kim, Dae Seung [Interdisciplinary Program in Radiation Applied Life Science, Dental Research Institute and BK21, College of Medicine, Seoul National University, Seoul (Korea, Republic of); Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul; Heo, Min Suk; Huh, Kyung Hoe; Kim, Myung Jin; Lee, Jee Ho [Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2009-09-15

    The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. We devised a patient-specific stent for patient-to-image registration and navigation. Three dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. The accuracy over 8 anatomical landmarks showed an overall mean of 0.56 {+-} 0.16 mm. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  16. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    Science.gov (United States)

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  17. A goggle navigation system for cancer resection surgery

    Science.gov (United States)

    Xu, Junbin; Shao, Pengfei; Yue, Ting; Zhang, Shiwu; Ding, Houzhu; Wang, Jinkun; Xu, Ronald

    2014-02-01

    We describe a portable fluorescence goggle navigation system for cancer margin assessment during oncologic surgeries. The system consists of a computer, a head mount display (HMD) device, a near infrared (NIR) CCD camera, a miniature CMOS camera, and a 780 nm laser diode excitation light source. The fluorescence and the background images of the surgical scene are acquired by the CCD camera and the CMOS camera respectively, co-registered, and displayed on the HMD device in real-time. The spatial resolution and the co-registration deviation of the goggle navigation system are evaluated quantitatively. The technical feasibility of the proposed goggle system is tested in an ex vivo tumor model. Our experiments demonstrate the feasibility of using a goggle navigation system for intraoperative margin detection and surgical guidance.

  18. Simple Scoring System to Predict In-Hospital Mortality After Surgery for Infective Endocarditis.

    Science.gov (United States)

    Gatti, Giuseppe; Perrotti, Andrea; Obadia, Jean-François; Duval, Xavier; Iung, Bernard; Alla, François; Chirouze, Catherine; Selton-Suty, Christine; Hoen, Bruno; Sinagra, Gianfranco; Delahaye, François; Tattevin, Pierre; Le Moing, Vincent; Pappalardo, Aniello; Chocron, Sidney

    2017-07-20

    Aspecific scoring systems are used to predict the risk of death postsurgery in patients with infective endocarditis (IE). The purpose of the present study was both to analyze the risk factors for in-hospital death, which complicates surgery for IE, and to create a mortality risk score based on the results of this analysis. Outcomes of 361 consecutive patients (mean age, 59.1±15.4 years) who had undergone surgery for IE in 8 European centers of cardiac surgery were recorded prospectively, and a risk factor analysis (multivariable logistic regression) for in-hospital death was performed. The discriminatory power of a new predictive scoring system was assessed with the receiver operating characteristic curve analysis. Score validation procedures were carried out. Fifty-six (15.5%) patients died postsurgery. BMI >27 kg/m 2 (odds ratio [OR], 1.79; P =0.049), estimated glomerular filtration rate 55 mm Hg (OR, 1.78; P =0.032), and critical state (OR, 2.37; P =0.017) were independent predictors of in-hospital death. A scoring system was devised to predict in-hospital death postsurgery for IE (area under the receiver operating characteristic curve, 0.780; 95% CI, 0.734-0.822). The score performed better than 5 of 6 scoring systems for in-hospital death after cardiac surgery that were considered. A simple scoring system based on risk factors for in-hospital death was specifically created to predict mortality risk postsurgery in patients with IE. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  19. Effect of an 8K ultra-high-definition television system in a case of laparoscopic gynecologic surgery.

    Science.gov (United States)

    Aoki, Yoichi; Matsuura, Masahiko; Chiba, Toshio; Yamashita, Hiromasa

    2017-09-01

    Various endoscopic devices have been developed for advanced minimally invasive surgery. We recently applied a new 8K ultra-high-definition television system during laparoscopic treatment of endometriosis. The procedure, which is described in detail, stands as the first reported application of an 8K ultra-high-definition system for laparoscopic gynecologic surgery. Comparison is made between depiction of the lesion by the new system and depiction by a full high-definition system. Improved diagnostic accuracy resulted from the increased image resolution, and we believe that this and other advantages will lead to widespread acceptance and further application of 8K ultra-high-definition systems in the field of gynecologic surgery.

  20. A Panoramic Wireless Endoscope System Design for the Application of Minimally Invasive Surgery

    Directory of Open Access Journals (Sweden)

    Chun-Hsiang Peng

    2014-05-01

    Full Text Available Minimally Invasive Surgery (MIS is the current trend in surgery. Compared to traditional surgery, MIS can substantially decrease recovery time and expenses needed by patients after surgeries, reduce pain during surgical procedures, and is highly regarded by physicians and patients. An endoscope is widely used in the diagnosis and treatments of various medical disciplines, such as hysteroscopy, laparoscopy, and colonoscopy, and have been adopted by many branches of medicine. However, the limited image field of MIS is often the most difficult obstacles faced by surgeons and medical students, especially to less experienced physicians and difficult surgical procedures; the limited field of view of endoscopic imaging does not provide a whole picture of the surgery area, making the procedures difficult and full of uncertainty. In light of this problem, we proposed a "Panoramic Wireless Endoscope System design", hoping to provide physicians with a wide field of view of the endoscopic image. We combine images captured from two parallel-mounted endoscope lenses into a single, wide-angle image, giving physicians a wider field of view and easier access to the surgical area. In addition, we developed a wireless transmission system so the image can be transmitted to various display platforms, eliminating the needs for excessive cabling on surgical tools and enable physicians to better operate on the patient. Finally, our system allows surgical assistants a better view of the operation process, and enables other physicians and nurses to remotely observe the process. Our experiment results have shown that we can increase the image to 152% of its original size. We used the PandaBoard ES platform with an ARM9 processor and 1G of onboard RAM, and continuously implementing animal trials to verify the reliability of our system.

  1. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  2. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study

    Science.gov (United States)

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365

  3. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study.

    Directory of Open Access Journals (Sweden)

    Liang Li

    Full Text Available To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery.In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems.The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons.The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.

  4. A computer-supported management of photographic documentation in plastic surgery - System development and its clinical application.

    Science.gov (United States)

    Korczak, Karol; Kasielska-Trojan, Anna; Niedźwiedziński, Marian; Antoszewski, Bogusław

    2017-07-01

    Photographic documentation is very important for plastic, reconstructive, and especially aesthetic surgery procedures. It can be used to improve patient care as well as to carry out scientific research. The results of our previous studies confirmed a strong demand for Information Technology (IT) systems dedicated to plastic surgery. Unfortunately, most of the solutions of this type are not suited to the actual needs. For this reason we decided to develop a reliable system for photographic documentation storage. The Plastic Reconstructive Esthetic Surgery Photo System (PRESsPhoto) was developed and finally deployed in the Plastic, Reconstructive and Aesthetic Surgery Clinic of the Medical University in Łódź (Poland). Preliminary single-center performance tests proved that the PRESsPhoto system is easy to use and provides, inter alia, rapid data search and data entry as well as data security. In the future the PRESsPhoto system should be able to cooperate with Hospital Information Systems (HIS). The process of development and deployment of the PRESsPhoto system is an example of good cooperation between health care providers and the informatics, which resulted in a system that meets the expectations of plastic surgeons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Development of the robot system to assist CT-guided brain surgery

    International Nuclear Information System (INIS)

    Koyama, H.; Funakubo, H.; Komeda, T.; Uchida, T.; Takakura, K.

    1999-01-01

    The robot technology was introduced into the stereotactic neurosurgery for application to biopsy, blind surgery, and functional neurosurgery. The authors have developed a newly designed the robot system to assist CT-guided brain surgery, designed to allow a biopsy needle to reach the targget such as a cerebral tumor within a brain automatically on the basis of the X,Y, and Z coordinates obtained by CT scanner. In this paper we describe construction of the robot, the control of the robot by CT image, robot simulation, and investigated a phantom experiment using CT image. (author)

  6. Preoperative multidisciplinary program for bariatric surgery: a proposal for the Brazilian Public Health System

    Directory of Open Access Journals (Sweden)

    Elinton Adami CHAIM

    Full Text Available ABSTRACT BACKGROUND Bariatric surgery has become the gold standard treatment for morbid obesity, but access to surgery remains difficult and low compliance to postoperative follow-up is common. To improve outcomes, enable access and optimize follow-up, we developed a multidisciplinary preoperative approach for bariatric surgery. OBJECTIVE To determine the impact of this program in the outcomes of bariatric surgery in the Brazilian public health system. METHODS A prospective evaluation of the individuals who underwent a preoperative multidisciplinary program for bariatric surgery and comparison of their surgical outcomes with those observed in the prospectively collected historical database of the individuals who underwent surgery before the beginning of the program. RESULTS There were 176 individuals who underwent the multidisciplinary program and 226 who did not. Individuals who underwent the program had significantly lower occurrence of the following variables: hospital stay; wound dehiscence; wound infection; pulmonary complications; anastomotic leaks; pulmonary thromboembolism; sepsis; incisional hernias; eventrations; reoperations; and mortality. Both loss of follow-up and weight loss failure were also significantly lower in the program group. CONCLUSION The adoption of a comprehensive preoperative multidisciplinary approach led to significant improvements in the postoperative outcomes and also in the compliance to the postoperative follow-up. It represents a reproducible and potentially beneficial approach within the context of the Brazilian public health system.

  7. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

    Science.gov (United States)

    López-Mir, F.; Naranjo, V.; Fuertes, J. J.; Alcañiz, M.; Bueno, J.; Pareja, E.

    2013-01-01

    Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery. PMID:24236293

  8. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

    Directory of Open Access Journals (Sweden)

    F. López-Mir

    2013-01-01

    Full Text Available Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery.

  9. Development and application of stent-based image guided navigation system for oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Lee, Woo Jin; Kim, Dae Seung; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul; Heo, Min Suk; Huh, Kyung Hoe; Kim, Myung Jin; Lee, Jee Ho

    2009-01-01

    The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. We devised a patient-specific stent for patient-to-image registration and navigation. Three dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. The accuracy over 8 anatomical landmarks showed an overall mean of 0.56 ± 0.16 mm. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  10. Indication for cataract surgery. Do we have evidence of who will benefit from surgery?

    DEFF Research Database (Denmark)

    Kessel, Line; Andresen, Jens; Erngaard, Ditte

    2015-01-01

    . To overcome this shortage of evidence, many systems have been developed internationally to prioritize patients on waiting lists for cataract surgery, but the Swedish NIKE (Nationell Indikationsmodell för Katarakt Ekstraktion) is the only system where an association to the preoperative scoring of a patient has...... been related to outcome of cataract surgery. We advise that clinicians are inspired by the NIKE system when they decide which patients to operate to ensure that surgery is only offered to patients who are expected to benefit from cataract surgery....

  11. Image-guided stereotactic surgery using ultrasonography and reconstructive three-dimensional CT-imaging system

    International Nuclear Information System (INIS)

    Kawamura, Hirotsune; Iseki, Hiroshi; Umezawa, Yoshihiro

    1991-01-01

    A new simulation and navigation system utilizing three-dimensional CT images has been developed for image-guided stereotactic surgery. Preoperative CT images are not always useful in predicting the intraoperative location of lesions, for cerebral lesions are easily displaced or distorted by gravity, brain retraction, and/or CSF aspiration during operative procedure. This new system, however, has the advantage that the intraoperative locations of intracranial lesions or the anatomical structures of the brain can be precisely confirmed during stereotactic surgery. Serial CT images were obtained from a patient whose head had been fixed to the ISEKI CT-guided stereotactic frame. The data of serial CT images were saved on a floppy disc and then transferred to the work station (IRIS) using the off line. In order to find the best approach angle for ultrasound-guided stereotactic surgery, three-dimenstional CT images were reconstructed using the work station. The site of the craniotomy or the angle of the trajectory of the ultrasound probe was measured preoperatively based on the three-dimensional CT images. Then, in the operating room, the patient's head was fixed to the ISEKI frame with the subframe at the same position as before according to the measurement of the CT images. In a case of cystic glioma, the predicable ultrasonograms from three-dimensional reconstructive CT images were ascertained to correspond well to the actual ultrasound images during ultrasound-guided stereotactic surgery. Therefore, the new simulation and navigation system can be judged to be a powerful operative supporting modality for correcting the locations of cerebral lesions; it allows one to perform stereotactic surgery more accurately and less invasively. (author)

  12. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs.

    Science.gov (United States)

    Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus

    2016-03-02

    A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs

  14. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    Science.gov (United States)

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  15. A VidEo-Based Intelligent Recognition and Decision System for the Phacoemulsification Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Shu Tian

    2015-01-01

    Full Text Available The phacoemulsification surgery is one of the most advanced surgeries to treat cataract. However, the conventional surgeries are always with low automatic level of operation and over reliance on the ability of surgeons. Alternatively, one imaginative scene is to use video processing and pattern recognition technologies to automatically detect the cataract grade and intelligently control the release of the ultrasonic energy while operating. Unlike cataract grading in the diagnosis system with static images, complicated background, unexpected noise, and varied information are always introduced in dynamic videos of the surgery. Here we develop a VidEo-Based Intelligent Recognitionand Decision (VEBIRD system, which breaks new ground by providing a generic framework for automatically tracking the operation process and classifying the cataract grade in microscope videos of the phacoemulsification cataract surgery. VEBIRD comprises a robust eye (iris detector with randomized Hough transform to precisely locate the eye in the noise background, an effective probe tracker with Tracking-Learning-Detection to thereafter track the operation probe in the dynamic process, and an intelligent decider with discriminative learning to finally recognize the cataract grade in the complicated video. Experiments with a variety of real microscope videos of phacoemulsification verify VEBIRD’s effectiveness.

  16. Risk-adjusted scoring systems in colorectal surgery.

    Science.gov (United States)

    Leung, Edmund; McArdle, Kirsten; Wong, Ling S

    2011-01-01

    Consequent to recent advances in surgical techniques and management, survival rate has increased substantially over the last 25 years, particularly in colorectal cancer patients. However, post-operative morbidity and mortality from colorectal cancer vary widely across the country. Therefore, standardised outcome measures are emphasised not only for professional accountability, but also for comparison between treatment units and regions. In a heterogeneous population, the use of crude mortality as an outcome measure for patients undergoing surgery is simply misleading. Meaningful comparisons, however, require accurate risk stratification of patients being analysed before conclusions can be reached regarding the outcomes recorded. Sub-specialised colorectal surgical units usually dedicated to more complex and high-risk operations. The need for accurate risk prediction is necessary in these units as both mortality and morbidity often are tools to justify the practice of high-risk surgery. The Acute Physiology And Chronic Health Evaluation (APACHE) is a system for classifying patients in the intensive care unit. However, APACHE score was considered too complex for general surgical use. The American Society of Anaesthesiologists (ASA) grade has been considered useful as an adjunct to informed consent and for monitoring surgical performance through time. ASA grade is simple but too subjective. The Physiological & Operative Severity Score for the enUmeration of Mortality and morbidity (POSSUM) and its variant Portsmouth POSSUM (P-POSSUM) were devised to predict outcomes in surgical patients in general, taking into account of the variables in the case-mix. POSSUM has two parts, which include assessment of physiological parameters and operative scores. There are 12 physiological parameters and 6 operative measures. The physiological parameters are taken at the time of surgery. Each physiological parameter or operative variable is sub-divided into three or four levels with

  17. Cost-Benefit Performance of Robotic Surgery Compared with Video-Assisted Thoracoscopic Surgery under the Japanese National Health Insurance System.

    Science.gov (United States)

    Kajiwara, Naohiro; Patrick Barron, James; Kato, Yasufumi; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    Medical economics have significant impact on the entire country. The explosion in surgical techniques has been accompanied by questions regarding actual improvements in outcome and cost-effectiveness, such as the da Vinci(®) Surgical System (dVS) compared with conventional video-assisted thoracic surgery (VATS). To establish a medical fee system for robot-assisted thoracic surgery (RATS), which is a system not yet firmly established in Japan. This study examines the cost benefit performance (CBP) based on medical fees compared with VATS and RATS under the Japanese National Health Insurance System (JNHIS) introduced in 2012. The projected (but as yet undecided) price in the JNHIS would be insufficient if institutions have less than even 200 dVS cases per year. Only institutions which perform more than 300 dVS operations per year would obtain a positive CBP with the projected JNHIS reimbursement. Thus, under the present conditions, it is necessary to perform at least 300 dVS operations per year in each institution with a dVS system to avoid financial deficit with current robotic surgical management. This may hopefully encourage a downward price revision of the dVS equipment by the manufacture which would result in a decrease in the cost per procedure.

  18. [ENT and head and neck surgery in the German DRG system 2007].

    Science.gov (United States)

    Franz, D; Roeder, N; Hörmann, K; Alberty, J

    2007-07-01

    The German DRG system has been further developed into version 2007. For ENT and head and neck surgery, significant changes in the coding of diagnoses and medical operations as well as in the the DRG structure have been made. New ICD codes for sleep apnoea and acquired tracheal stenosis have been implemented. Surgery on the acoustic meatus, removal of auricle hyaline cartilage for transplantation (e. g. rhinosurgery) and tonsillotomy have been coded in the 2007 version. In addition, the DRG structure has been improved. Case allocation of more than one significant operation has been established. The G-DRG system has gained in complexity. High demands are made on the coding of complex cases, whereas standard cases require mostly only one specific diagnosis and one specific OPS code. The quality of case allocation for ENT patients within the G-DRG system has been improved. Nevertheless, further adjustments of the G-DRG system are necessary.

  19. A novel augmented reality system for displaying inferior alveolar nerve bundles in maxillofacial surgery.

    Science.gov (United States)

    Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng

    2017-02-15

    Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the "integrated image" on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications.

  20. The Application of Three-Dimensional Surface Imaging System in Plastic and Reconstructive Surgery.

    Science.gov (United States)

    Li, Yanqi; Yang, Xin; Li, Dong

    2016-02-01

    Three-dimensional (3D) surface imaging system has gained popularity worldwide in clinical application. Unlike computed tomography and magnetic resonance imaging, it has the ability to capture 3D images with both shape and texture information. This feature has made it quite useful for plastic surgeons. This review article is mainly focusing on demonstrating the current status and analyzing the future of the application of 3D surface imaging systems in plastic and reconstructive surgery.Currently, 3D surface imaging system is mainly used in plastic and reconstructive surgery to help improve the reliability of surgical planning and assessing surgical outcome objectively. There have already been reports of its using on plastic and reconstructive surgery from head to toe. Studies on facial aging process, online applications development, and so on, have also been done through the use of 3D surface imaging system.Because different types of 3D surface imaging devices have their own advantages and disadvantages, a basic knowledge of their features is required and careful thought should be taken to choose the one that best fits a surgeon's demand.In the future, by integrating with other imaging tools and the 3D printing technology, 3D surface imaging system will play an important role in individualized surgical planning, implants production, meticulous surgical simulation, operative techniques training, and patient education.

  1. Ostomy Surgery of the Bowel

    Science.gov (United States)

    ... Digestive System & How it Works Zollinger-Ellison Syndrome Ostomy Surgery of the Bowel What is ostomy surgery of the bowel? Ostomy surgery of the ... of the body. Why does a person need ostomy surgery of the bowel? A person may need ...

  2. The Needs of Hybrid Systems Configuration for Real - Time Decision - Making Process in Surgery

    National Research Council Canada - National Science Library

    Tritto, G

    2001-01-01

    ...: sensors, actuators, mechatronic systems and tools in Minimally Invasive Surgery (MIS) and Microsurgery require nonlinear interpretation and control systems to interface with the computer-assisted decision making process of the surgeon at work...

  3. Bitot’s Spots following Bariatric Surgery: An Ocular Manifestation of a Systemic Disease

    Directory of Open Access Journals (Sweden)

    Amanda R. Crum

    2017-12-01

    Full Text Available Background: To present a case of ocular complications from vitamin A deficiency following bariatric surgery. Case Report: A 41-year-old woman presented with symptoms of dryness and diminished night vision. Examination revealed corneal punctate staining, keratinization of the conjunctiva, and multiple mid-peripheral white lesions at the level of the retinal pigment epithelium. Given the patient’s history of bariatric surgery, anemia, and vitamin D deficiency, further investigation into micronutrient levels was performed and indicated a severe vitamin A deficiency. Oral vitamin A supplementation resulted in the complete resolution of her symptoms within two months. Conclusions: Nutritional deficiencies following bariatric surgery are common and can be disruptive to normal systemic health and visual function. Given that the number of patients pursuing bariatric surgery for weight loss management has increased over the past 50 years, eye care professionals should be aware of the ophthalmic manifestations associated with micronutrient deficiency.

  4. Fungal endophthalmitis caused by Paecilomyces variotii following cataract surgery: a presumed operating room air-conditioning system contamination.

    Science.gov (United States)

    Tarkkanen, Ahti; Raivio, Virpi; Anttila, Veli-Jukka; Tommila, Petri; Ralli, Reijo; Merenmies, Lauri; Immonen, Ilkka

    2004-04-01

    To report a case of delayed fungal endophthalmitis by Paecilomyces variotii following uncomplicated cataract surgery. To our knowledge this is the first reported case of postoperative endophthalmitis by this species. We report the longterm clinical follow-up of an 83-year-old female who underwent uncomplicated sutureless, small-incision cataract surgery. She developed recurring uveitis 4 months after surgery. Vitreous tap and finally complete vitrectomy with removal of the capsular bag including the intraocular lens were performed. Fungi were studied by histopathology and culture. At histopathological examination, the fungi were found to be closely related with the capsular bag. A few mononuclear inflammatory cells were encountered. At culture, Paecilomyces variotii, a common ubiquitous non-pathogenic saprophyte, was identified. Despite systemic, intravitreal and topical antifungal therapy after vitrectomy the uveitis recurred several times, but no fungal organisms were isolated from the repeat intraocular specimen. At 18 months postoperatively the subject's visual acuity was finger counting at 2 metres. At the time of surgery the operating room air-conditioning system was undergoing repairs. Cases of fungal endophthalmitis after contamination from air-conditioning ventilation systems have been reported before, but none of the cases reported have been caused by P. variotii. P. variotii, a non-pathogenic environmental saprophyte, may be disastrous if introduced into the eye. International recommendations on the environmental control of the operating room air-conditioning ventilation system should be strictly followed. No intraoperative surgery should be undertaken while the air-conditioning system is undergoing repairs or service.

  5. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    Science.gov (United States)

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  6. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    Science.gov (United States)

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2017-09-01

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  7. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    Energy Technology Data Exchange (ETDEWEB)

    Landman, Joanne [Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia); Kulawansa, Sagarika [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia (Australia); McCarthy, Michael; Troedson, Russell [Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia); Phillips, Michael [Western Australian Institute for Medical Research, University of Western Australia, Perth, Western Australia (Australia); Tinning, Jill [The Multidisciplinary Breast Service, Royal Perth Hospital, Perth, Western Australia (Australia); Taylor, Donna, E-mail: Donna.Taylor@health.wa.gov.au [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia (Australia); School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia)

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphy and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.

  8. An overview of surgery-first approach: Recent advances in orthognathic surgery.

    Science.gov (United States)

    Sharma, Vipul Kumar; Yadav, Kirti; Tandon, Pradeep

    2015-01-01

    The disadvantages of having orthodontic interventions both before and after orthognathic surgery include a long treatment time of 7-47 months and temporary worsening of facial appearance. Nowadays, the concept of surgery-first, followed by orthodontic treatment is applied to orthognathic surgery cases in different orthodontic centers in the world. This concept and technique is called "surgery-first-orthognathic-approach" or "surgery-first approach" (SFA) rigid fixation (skeletal anchorage system) of the bony segments and regional acceleratory phenomenon were keys to broad implementation of the SFA. This article is intended to provide an overview of SFA including indications, general and specific guidelines, different protocol variations, success rate and potential problems.

  9. Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system.

    Science.gov (United States)

    Lee, Kyung-Min; Kwon, Hyung-Goo; Joo, Choun-Ki

    2009-05-01

    To compare clinical outcomes of a 1.8 mm and a 2.2 mm microcoaxial cataract surgery system. Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. In a prospective study, eyes were randomly selected to have phacoemulsification using a Stellaris system or an Intrepid Infiniti system. The initial incision size was 1.8 mm and 2.2 mm, respectively. Measured intraoperative parameters included phacoemulsification time, mean cumulative dissipated ultrasound energy (CDE), change in incision size at each step of surgery, and total volume of balanced salt solution (BSS) used. The best corrected visual acuity (BCVA), corneal astigmatism, corneal thickness, and endothelial cell count were evaluated preoperatively and postoperatively. The study evaluated 86 eyes of 78 patients (43 eyes in each group). There were no significant differences in postoperative BCVA, surgically induced astigmatism, or amount of BSS used between the 2 systems (P >.05). However, for high-density cataracts, the 1.8 mm group had a greater change between the initial incision size and the incision size after phacoemulsification (P = .019, nuclear opalescence [NO] NO3; P = .001, NO4), a longer phacoemulsification time (P = .013, NO3), greater mean CDE (P = .005, NO3; P = .001, NO4), and greater corneal endothelial cell loss (P = .003, NO4). Both systems were safe and effective in microcoaxial phacoemulsification. The 1.8 mm system performed better with cortical-type cataract and the 2.2 mm system, with high-density nuclear-type cataract.

  10. Impact of an Event Reporting System on Resident Complication Reporting in Plastic Surgery Training: Addressing an ACGME and Plastic Surgery Milestone Project Core Competency.

    Science.gov (United States)

    Parikh, Rajiv P; Snyder-Warwick, Alison; Naidoo, Sybill; Skolnick, Gary B; Patel, Kamlesh B

    2017-11-01

    The Accreditation Council for Graduate Medical Education and Plastic Surgery Milestone Project has identified practice-based learning and improvement, which involves systematically analyzing current practices and implementing changes, as a core competency in residency education. In surgical care, complication reporting is an essential component of practice-based learning and improvement as complications are analyzed in morbidity and mortality conference for quality improvement. Unfortunately, current methods for capturing a comprehensive profile of complications may significantly underestimate the true occurrence of complications. Therefore, the objectives of this study are to evaluate an intervention for complication reporting and compare this to current practice, in a plastic surgery training program. This is a preintervention and postintervention study evaluating resident reporting of complications on a plastic surgery service. The intervention was an online event reporting system developed by department leadership and patient safety experts. The cohorts consisted of all patients undergoing surgery during two separate 3-month blocks bridged by an implementation period. A trained reviewer recorded complications, and this served as the reference standard. Fisher's exact test was used for binary comparisons. There were 32 complications detected in 219 patients from June to August of 2015 and 35 complications in 202 patients from October to December of 2015. The proportion of complications reported in the preintervention group was nine of 32 (28.1 percent). After the intervention, this significantly increased to 32 of 35 (91.4 percent) (p < 0.001). An intervention using an event reporting system, supported by departmental leadership, led to significant improvements in complication reporting by plastic surgery residents.

  11. Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    Directory of Open Access Journals (Sweden)

    L. Vermeeren

    2009-01-01

    Full Text Available Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described.

  12. Effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA1c.

    Science.gov (United States)

    Chadburn, Andrew J; Garman, Elizabeth; Abbas, Raad; Modupe, Anu; Ford, Clare; Thomas, Osmond L; Chugh, Sanjiv; Deshpande, Shreeram; Gama, Rousseau

    2017-07-01

    Background In acutely ill patients with new onset hyperglycaemia, plasma glucose cannot reliably distinguish between stress hyperglycaemia and undiagnosed diabetes mellitus. We, therefore, investigated the diagnostic reliability of glycated haemoglobin (HbA1c) in acute illness by prospectively evaluating the effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA 1c . Methods HbA 1c and serum C-reactive protein concentrations were compared before and two days after elective knee or hip surgery in 30 patients without diabetes. C-reactive protein was used to assess the systemic inflammatory response. Results The mean (standard deviation) serum C-reactive protein increased following surgery (4.8 [7.5] vs. 179.7 [61.9] mg/L; P<0.0001). HbA 1c was similar before and after surgery (39.2 [5.4] vs. 38.1 [5.1] mmol/moL, respectively; P = 0.4363). Conclusions HbA 1c is unaffected within two days of a systemic inflammatory response as provoked by elective orthopaedic surgery. This suggests that HbA 1c may be able to differentiate newly presenting type 2 diabetes mellitus from stress hyperglycaemia in acutely ill patients with new onset hyperglycaemia.

  13. Implementation of Enhanced Recovery After Surgery: a strategy to transform surgical care across a health system.

    Science.gov (United States)

    Gramlich, Leah M; Sheppard, Caroline E; Wasylak, Tracy; Gilmour, Loreen E; Ljungqvist, Olle; Basualdo-Hammond, Carlota; Nelson, Gregg

    2017-05-19

    Enhanced Recovery After Surgery (ERAS) programs have been shown to have a positive impact on outcome. The ERAS care system includes an evidence-based guideline, an implementation program, and an interactive audit system to support practice change. The purpose of this study is to describe the use of the Theoretic Domains Framework (TDF) in changing surgical care and application of the Quality Enhancement Research Initiative (QUERI) model to analyze end-to-end implementation of ERAS in colorectal surgery across multiple sites within a single health system. The ultimate intent of this work is to allow for the development of a model for spread, scale, and sustainability of ERAS in Alberta Health Services (AHS). ERAS for colorectal surgery was implemented at two sites and then spread to four additional sites. The ERAS Interactive Audit System (EIAS) was used to assess compliance with the guidelines, length of stay, readmissions, and complications. Data sources informing knowledge translation included surveys, focus groups, interviews, and other qualitative data sources such as minutes and status updates. The QUERI model and TDF were used to thematically analyze 189 documents with 2188 quotes meeting the inclusion criteria. Data sources were analyzed for barriers or enablers, organized into a framework that included individual to organization impact, and areas of focus for guideline implementation. Compliance with the evidence-based guidelines for ERAS in colorectal surgery at baseline was 40%. Post implementation compliance, consistent with adoption of best practice, improved to 65%. Barriers and enablers were categorized as clinical practice (22%), individual provider (26%), organization (19%), external environment (7%), and patients (25%). In the Alberta context, 26% of barriers and enablers to ERAS implementation occurred at the site and unit levels, with a provider focus 26% of the time, a patient focus 26% of the time, and a system focus 22% of the time. Using the

  14. Tailored patient information using a database system: Increasing patient compliance in a day surgery setting

    DEFF Research Database (Denmark)

    Grode, Jesper Nicolai Riis; Grode, Louise; Steinsøe, Ulla

    rehabilitation. The hospital is responsible of providing the patients with accurate information enabling the patient to prepare for surgery. Often patients are overloaded with uncoordinated information, letters and leaflets. The contribution of this project is a database system enabling health professionals...... to empower patients through tailored individualized information. Performing 6500 operations per year at our Day Surgery Centre, health professionals need a computer based system to create individualized information material. Health professionals must be able to adapt the information material quickly...... was established to support these requirements. A relational database system holds all information pieces in a granular, structured form. Each individual piece of information can be joined with other pieces thus supporting the tailoring of information. A web service layer caters for integration with output systems...

  15. Gastrointestinal robot-assisted surgery. A current perspective.

    Science.gov (United States)

    Lunca, Sorinel; Bouras, George; Stanescu, Alexandru Calin

    2005-12-01

    Minimally invasive techniques have revolutionized operative surgery. Computer aided surgery and robotic surgical systems strive to improve further on currently available minimally invasive surgery and open new horizons. Only several centers are currently using surgical robots and publishing data. In gastrointestinal surgery, robotic surgery is applied to a wide range of procedures, but is still in its infancy. Cholecystectomy, Nissen fundoplication and Heller myotomy are among the most frequently performed operations. The ZEUS (Computer Motion, Goleta, CA) and the da Vinci (Intuitive Surgical, Mountain View, CA) surgical systems are today the most advanced robotic systems used in gastrointestinal surgery. Most studies reported that robotic gastrointestinal surgery is feasible and safe, provides improved dexterity, better visualization, reduced fatigue and high levels of precision when compared to conventional laparoscopic surgery. Its main drawbacks are the absence of force feedback and extremely high costs. At this moment there are no reports to clearly demonstrate the superiority of robotics over conventional laparoscopic surgery. Further research and more prospective randomized trials are needed to better define the optimal application of this new technology in gastrointestinal surgery.

  16. Robotic assisted minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Palep Jaydeep

    2009-01-01

    Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.

  17. Feasibility of real-time location systems in monitoring recovery after major abdominal surgery.

    Science.gov (United States)

    Dorrell, Robert D; Vermillion, Sarah A; Clark, Clancy J

    2017-12-01

    Early mobilization after major abdominal surgery decreases postoperative complications and length of stay, and has become a key component of enhanced recovery pathways. However, objective measures of patient movement after surgery are limited. Real-time location systems (RTLS), typically used for asset tracking, provide a novel approach to monitoring in-hospital patient activity. The current study investigates the feasibility of using RTLS to objectively track postoperative patient mobilization. The real-time location system employs a meshed network of infrared and RFID sensors and detectors that sample device locations every 3 s resulting in over 1 million data points per day. RTLS tracking was evaluated systematically in three phases: (1) sensitivity and specificity of the tracking device using simulated patient scenarios, (2) retrospective passive movement analysis of patient-linked equipment, and (3) prospective observational analysis of a patient-attached tracking device. RTLS tracking detected a simulated movement out of a room with sensitivity of 91% and specificity 100%. Specificity decreased to 75% if time out of room was less than 3 min. All RTLS-tagged patient-linked equipment was identified for 18 patients, but measurable patient movement associated with equipment was detected for only 2 patients (11%) with 1-8 out-of-room walks per day. Ten patients were prospectively monitored using RTLS badges following major abdominal surgery. Patient movement was recorded using patient diaries, direct observation, and an accelerometer. Sensitivity and specificity of RTLS patient tracking were both 100% in detecting out-of-room ambulation and correlated well with direct observation and patient-reported ambulation. Real-time location systems are a novel technology capable of objectively and accurately monitoring patient movement and provide an innovative approach to promoting early mobilization after surgery.

  18. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Guillermo M.; Elizondo, Maria L. [CORE Dental Clinic, Resistencia (Argentina)

    2014-06-15

    The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

  19. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    International Nuclear Information System (INIS)

    Rosa, Guillermo M.; Elizondo, Maria L.

    2014-01-01

    The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

  20. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  1. [Computer assisted orthognathic surgery: Condyle repositioning.

    Science.gov (United States)

    Bettega, G; Leitner, F

    2013-07-17

    Computer aided surgery has become a standard in many fields. It is rarely used in orthognathic surgery. Twenty years ago, we developed a navigation system adapted to this surgery, especially for mandibular condyle repositioning. The system has been improved along with technological progress. The authors of several clinical studies have validated this system. It is now routinely used in our department, because of its educational virtues among other assets. Copyright © 2013. Published by Elsevier Masson SAS.

  2. Assessment of the Mexican Board of Pediatric Surgery Certification System.

    Science.gov (United States)

    Porras-Hernandez, Juan D; Mora-Fol, Jose R; Lezama-Del Valle, Pablo; Yanowsky-Reyes, Guillermo; Perez-Lorenzana, Hector; Ortega-Salgado, Arturo; Aguirre-Jauregui, Oscar; Bracho-Blanchet, Eduardo; Sanchez-Mendiola, Melchor

    2015-01-01

    To evaluate the quality of the Mexican Board of Pediatric Surgery (MBPS) certifying system, using contemporary international guidelines. Retrospective assessment of evidence collected during the design and implementation processes of 2 consecutive applications of the MBPS certifying examination, using Cizek's checklist for evaluating credential-testing programs. It includes the relevant guidelines from the American Education Research Association, the American Psychological Association, the National Council on Measurement in Education, and the National Commission for Certifying Agencies. Four independent and previously trained raters used the checklist. They underwent a 2-week training using frame-of-reference and performance dimensions methodologies. Certification examinations of MBPS. The 2013 and 2014 MBPS certification examinations, with 111 evidence items of the processes, followed for the assessment of 86 examinees. The checklist internal consistency was 0.89. Absolute interrater agreement was 0.34 for the 2013 and 0.66 for the 2014 editions of the examination. The 2013 examination complied with 55 (64%) of the checklist 86 items, in 2014 with 72 (84%). In 2014, the certifying system reached a quality of 84%. For optimal fulfillment of its social responsibility, the MBPS is required to maintain its level of quality and attempt to improve its performance. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. Cloud-Based Service Information System for Evaluating Quality of Life after Breast Cancer Surgery.

    Directory of Open Access Journals (Sweden)

    Hao-Yun Kao

    Full Text Available Although recent studies have improved understanding of quality of life (QOL outcomes of breast conserving surgery, few have used longitudinal data for more than two time points, and few have examined predictors of QOL over two years. Additionally, the longitudinal data analyses in such studies rarely apply the appropriate statistical methodology to control for censoring and inter-correlations arising from repeated measures obtained from the same patient pool. This study evaluated an internet-based system for measuring longitudinal changes in QOL and developed a cloud-based system for managing patients after breast conserving surgery.This prospective study analyzed 657 breast cancer patients treated at three tertiary academic hospitals. Related hospital personnel such as surgeons and other healthcare professionals were also interviewed to determine the requirements for an effective cloud-based system for surveying QOL in breast cancer patients. All patients completed the SF-36, Quality of Life Questionnaire (QLQ-C30 and its supplementary breast cancer measure (QLQ-BR23 at baseline, 6 months, 1 year, and 2 years postoperatively. The 95% confidence intervals for differences in responsiveness estimates were derived by bootstrap estimation. Scores derived by these instruments were interpreted by generalized estimating equation before and after surgery.All breast cancer surgery patients had significantly improved QLQ-C30 and QLQ-BR23 subscale scores throughout the 2-year follow-up period (p<0.05. During the study period, QOL generally had a negative association with advanced age, high Charlson comorbidity index score, tumor stage III or IV, previous chemotherapy, and long post-operative LOS. Conversely, QOL was positively associated with previous radiotherapy and hormone therapy. Additionally, patients with high scores for preoperative QOL tended to have high scores for QLQ-C30, QLQ-BR23 and SF-36 subscales. Based on the results of usability testing

  4. Real-Time Augmented Reality for Robotic-Assisted Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2015-01-01

    Training in robotic-assisted minimally invasive surgery is crucial, but the training with actual surgery robots is relatively expensive. Therefore, improving the efficiency of this training is of great interest in robotic surgical education. One of the current limitations of this training is the ......-dimensional computer graphics in real time. Our system makes it possible to easily deploy new user interfaces for robotic-assisted surgery training. The system has been positively evaluated by two experienced instructors in robot-assisted surgery....... is the limited visual communication between the instructor and the trainee. As the trainee's view is limited to that of the surgery robot's camera, even a simple task such as pointing is difficult. We present a compact system to overlay the video streams of the da Vinci surgery systems with interactive three...

  5. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    Science.gov (United States)

    Elizondo, María L.

    2014-01-01

    Purpose The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties. PMID:24944966

  6. [Financing of inpatient orthopedics and trauma surgery in the G-DRG system 2010].

    Science.gov (United States)

    Franz, D; Schemmann, F; Roeder, N; Mahlke, L

    2010-08-01

    The German DRG (diagnosis-related groups) system forms the basis for billing inpatient hospital services. It includes not only the case groups (G-DRGs), but also additional and innovation payments. This paper analyzes and evaluates the relevant developments of the G-DRG System 2010 for orthopedics and traumatology from the medical and classification perspectives. Analyses of relevant diagnoses, medical procedures and G-DRGs in the versions 2009 and 2010 based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI) were carried out. The DRG catalog is has grown from 8 to 1,200 G-DRGs. A number of codes for surgical measures have been newly established or modified. Here, the identification and the correct and performance-based mapping of complex and elaborate scenarios was again the focus of the restructuring of the G-DRG system. The G-DRG structure in orthopedics and traumatology has been changed, especially in the areas of spinal surgery and surgery of the upper and lower extremities. The actual impact of the changes may vary depending on the individual hospital services. For the first time since the introduction of the G-DRG system, the pure numerical changes at the level of DRGs themselves are so marginal that only part of the DRG users in the hospitals will register them. The changes implemented not only a high selectivity between complex and less complex scenarios, but partly also unintended and unjustified revaluation of less complex measures. The G-DRG system has gained complexity again. Especially the G-DRG allocation of spinal surgery and multiple surgical interventions of the upper and/or lower extremities have reached such a complexity that only a few DRG users can follow them.

  7. Robotic-assisted surgery in ophthalmology.

    Science.gov (United States)

    de Smet, Marc D; Naus, Gerrit J L; Faridpooya, Koorosh; Mura, Marco

    2018-05-01

    Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.

  8. Surgery of the eloquent area using neuronavigation system

    International Nuclear Information System (INIS)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira; Ono, Hidetoshi; Goto, Takumi; Aburano, Tamio

    2001-01-01

    The purpose of this minimally invasive study was to evaluate the efficacy of a neuronavigation system for surgery of lesions near Broca's area, skull base, or paracentral sulcus. With regards to paracentral sulcus lesions, precise localization of the precentral gyrus was evaluated not only with preoperative 3D images of the brain but also confirmed by the combination of fMRI and intraoperative SEP. Using the neuronavigation system, Viewing Wand (ISG Technologies), three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus and skull representations obtained by MRI and CT. Six patients with lesions near Broca's area, 5 patients with skull base lesions, and 9 patients with lesions near the central sulcus were analyzed. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm, which was composed of repetition of rest-task every in 30 seconds for 150 seconds, in a 1.5-tesla echo-speed MR imager (Signa Horizon; General Electric Medical Systems, Milwaukee, WI). Statistical cross-correlation functional maps were generated and overlaid onto high-resolution anatomical MR images. Presurgical assessment of 3D reconstructed brain images were performed in all cases. They were analyzed in Broca's lesions, skull base lesions and paracentral sulcus lesions and were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. In fMRI, motor activation sites were obtained on both ipsilateral and contralateral hemispheres in all patients except for one patient with a hemorrhagic cyst. Locations of precentral gyri were predicted preoperatively. In all patients except for one case, fMRI was obtained even in tumor patient in whom intraoperative SEP was technically not feasible due to severe cortical brain damage from the paracentral tumor. The precentral gyri identified by 3D reconstructed brain images coincided well

  9. A novel navigation system for maxillary positioning in orthognathic surgery: Preclinical evaluation.

    Science.gov (United States)

    Lutz, Jean-Christophe; Nicolau, Stéphane; Agnus, Vincent; Bodin, Frédéric; Wilk, Astrid; Bruant-Rodier, Catherine; Rémond, Yves; Soler, Luc

    2015-11-01

    Appropriate positioning of the maxilla is critical in orthognathic surgery. As opposed to splint-based positioning, navigation systems are versatile and appropriate in assessing the vertical dimension. Bulk and disruption to the line of sight are drawbacks of optical navigation systems. Our aim was to develop and assess a novel navigation system based on electromagnetic tracking of the maxilla, including real-time registration of head movements. Since the software interface has proved to greatly influence the accuracy of the procedure, we purposely designed and evaluated an original, user-friendly interface. A sample of 12 surgeons had to navigate the phantom osteotomized maxilla to eight given target positions using the software we have developed. Time and accuracy (translational error and angular error) were compared between a conventional and a navigated session. A questionnaire provided qualitative evaluation. Our system definitely allows a reduction in variability of time and accuracy among different operators. Accuracy was improved in all surgeons (mean terror difference = 1.11 mm, mean aerror difference = 1.32°). Operative time was decreased in trainees. Therefore, they would benefit from such a system that could also serve for educational purposes. The majority of surgeons who strongly agreed that such a navigation system would prove very helpful in complex deformities, also stated that it would be helpful in everyday orthognathic procedures. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. SiPM arrays and miniaturized readout electronics for compact gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N., E-mail: dinu@lal.in2p3.fr [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Imando, T. Ait; Nagai, A. [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Pinot, L. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France); Puill, V. [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Callier, S. [Omega Microelectronics Group, CNRS, Palaiseau (France); Janvier, B.; Esnault, C.; Verdier, M.-A. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France); Raux, L. [Omega Microelectronics Group, CNRS, Palaiseau (France); Vandenbussche, V.; Charon, Y.; Menard, L. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France)

    2015-07-01

    This article reports on the design and features of a very compact and light gamma camera based on SiPM arrays and miniaturized readout electronics dedicated to tumor localization during radio-guided cancer surgery. This gamma camera, called MAGICS, is composed of four (2×2) photo-detection elementary modules coupled to an inorganic scintillator. The 256 channels photo-detection system covers a sensitive area of 54×53 m{sup 2}. Each elementary module is based on four (2×2) SiPM monolithic arrays, each array consisting of 16 SiPM photo-sensors (4×4) with 3×3 mm{sup 2} sensitive area, coupled to a miniaturized readout electronics and a dedicated ASIC. The overall dimensions of the electronics fit the size of the detector, enabling to assemble side-by-side several elementary modules in a close-packed arrangement. The preliminary performances of the system are very encouraging, showing an energy resolution of 9.8% and a spatial resolution of less than 1 mm at 122 keV.

  11. Clinical Application of Different Surgical Navigation Systems in Complex Craniomaxillofacial Surgery: The Use of Multisurface 3-Dimensional Images and a 2-Plane Reference System.

    Science.gov (United States)

    Liu, Tom J; Ko, An-Ta; Tang, Yueh-Bih; Lai, Hong-Shiee; Chien, Hsiung-Fei; Hsieh, Thomas Mon-Hsian

    2016-04-01

    Intraoperative navigation is a tool that provides surgeons with real-time guidance based on patients' preoperative imaging studies. The application of intraoperative navigation to neurosurgery and otolaryngology has been well documented; however, only isolated reports have analyzed its potential in the field of craniomaxillofacial surgery. From November 2010 to July 2014, 15 patients were operated on for complex craniomaxillofacial surgery with assistance by 3 different navigation systems, which used either infrared or electromagnetic technologies. We imported fine-cut (0.625-mm) computed tomographic scan images of the patients to the navigation systems whose software processed them into multisurface 3-dimentional models used as guiding material for the surgical navigation. We also developed a simple "2-plane reference system" to ensure that the final results were symmetric to the normal half of the face. Appearance outcome was evaluated by questionnaire. Of these 15 cases, 3 cases were performed with infrared-based navigation, and the remaining 12 cases were accomplished by electromagnetic technology. Most of these cases resulted in satisfactory outcomes after tumor resection, posttraumatic reconstruction, and postablative reconstruction. Navigation systems offer highly valuable intraoperative assistance in complex craniomaxillofacial surgery. Not only can these systems pinpoint deep-seated lesions as neurosurgeons or otolaryngologists do, but they can also use a simple 2-plane reference system for accurate bone alignment. Moreover, advancements in multisurface 3-D models provide us more reliable intuitive image guidance. The application of electromagnetic technology, with its smaller reference obviation of the line-of-sight problem, makes the manipulation of craniomaxillofacial surgery more comfortable.

  12. Initial evaluation of a femtosecond laser system in cataract surgery.

    Science.gov (United States)

    Chang, John S M; Chen, Ivan N; Chan, Wai-Man; Ng, Jack C M; Chan, Vincent K C; Law, Antony K P

    2014-01-01

    To report the early experience and complications during cataract surgery with a noncontact femtosecond laser system. Hong Kong Sanatorium and Hospital, Hong Kong Special Administrative Region, China. Retrospective case series. All patients had anterior capsulotomy or combined anterior capsulotomy and lens fragmentation using a noncontact femtosecond laser system (Lensar) before phacoemulsification. Chart and video reviews were performed retrospectively to determine the intraoperative complication rate. Risk factors associated with the complications were also analyzed. One hundred seventy eyes were included. Free-floating capsule buttons were found in 151 eyes (88.8%). No suction break occurred in any case. Radial anterior capsule tears occurred in 9 eyes (5.3%); they did not extend to the equator or posterior capsule. One eye (0.6%) had a posterior capsule tear. No capsular block syndrome developed, and no nuclei were dropped during irrigation/aspiration (I/A). Anterior capsule tags and miosis occurred in 4 eyes (2.4%) and 17 eyes (10.0%), respectively. Different severities of subconjunctival hemorrhages developed in 71 (43.8%) of 162 eyes after the laser procedure. The mean surgical time from the beginning to the end of suction was 6.72 minutes ± 4.57 (SD) (range 2 to 28 minutes). Cataract surgery with the noncontact femtosecond laser system was safe. No eye lost vision because of complications. Caution should be taken during phacoemulsification and I/A to avoid radial anterior capsule tears and posterior capsule tears. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. A clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery

    Science.gov (United States)

    Liu, Wen P.; Mirota, Daniel J.; Uneri, Ali; Otake, Yoshito; Hager, Gregory; Reh, Douglas D.; Ishii, Masaru; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2012-02-01

    Augmentation of endoscopic video with preoperative or intraoperative image data [e.g., planning data and/or anatomical segmentations defined in computed tomography (CT) and magnetic resonance (MR)], can improve navigation, spatial orientation, confidence, and tissue resection in skull base surgery, especially with respect to critical neurovascular structures that may be difficult to visualize in the video scene. This paper presents the engineering and evaluation of a video augmentation system for endoscopic skull base surgery translated to use in a clinical study. Extension of previous research yielded a practical system with a modular design that can be applied to other endoscopic surgeries, including orthopedic, abdominal, and thoracic procedures. A clinical pilot study is underway to assess feasibility and benefit to surgical performance by overlaying CT or MR planning data in realtime, high-definition endoscopic video. Preoperative planning included segmentation of the carotid arteries, optic nerves, and surgical target volume (e.g., tumor). An automated camera calibration process was developed that demonstrates mean re-projection accuracy (0.7+/-0.3) pixels and mean target registration error of (2.3+/-1.5) mm. An IRB-approved clinical study involving fifteen patients undergoing skull base tumor surgery is underway in which each surgery includes the experimental video-CT system deployed in parallel to the standard-of-care (unaugmented) video display. Questionnaires distributed to one neurosurgeon and two otolaryngologists are used to assess primary outcome measures regarding the benefit to surgical confidence in localizing critical structures and targets by means of video overlay during surgical approach, resection, and reconstruction.

  14. Robotics in General Surgery

    OpenAIRE

    Wall, James; Chandra, Venita; Krummel, Thomas

    2008-01-01

    In summary, robotics has made a significant contribution to General Surgery in the past 20 years. In its infancy, surgical robotics has seen a shift from early systems that assisted the surgeon to current teleoperator systems that can enhance surgical skills. Telepresence and augmented reality surgery are being realized, while research and development into miniaturization and automation is rapidly moving forward. The future of surgical robotics is bright. Researchers are working to address th...

  15. Minimally invasive single-site surgery for the digestive system: A technological review

    Directory of Open Access Journals (Sweden)

    Dhumane Parag

    2011-01-01

    Full Text Available Minimally Invasive Single Site (MISS surgery is a better terminology to explain the novel concept of scarless surgery, which is increasingly making its way into clinical practice. But, there are some difficulties. We review the existing technologies for MISS surgery with regards to single-port devices, endoscope and camera, instruments, retractors and also the future perspectives for the evolution of MISS surgery. While we need to move ahead cautiously and wait for the development of appropriate technology, we believe that the "Ultimate form of Minimally Invasive Surgery" will be a hybrid form of MISS surgery and Natural Orifice Transluminal Endoscopic Surgery, complimented by technological innovations from the fields of robotics and computer-assisted surgery.

  16. Preoperative renin-angiotensin system inhibitors protect renal function in aging patients undergoing cardiac surgery.

    Science.gov (United States)

    Barodka, Viachaslau; Silvestry, Scott; Zhao, Ning; Jiao, Xiangyin; Whellan, David J; Diehl, James; Sun, Jian-Zhong

    2011-05-15

    Renal failure (RF) represents a major postoperative complication for elderly patients undergoing cardiac surgery. This observational cohort study examines effects of preoperative use of renin-angiotensin system (RAS) inhibitors on postoperative renal failure in aging patients undergoing cardiac surgery. We retrospectively analyzed a cohort of 1287 patients who underwent cardiac surgery at this institution (2003-2007). The patients included were ≥65 years old, scheduled for elective cardiac surgery, and without preexisting RF (defined by the criteria of the Society of Thoracic Surgeons as described in Method). Of all patients evaluated, 346 patients met the inclusion criteria and were divided into two groups: using (n = 122) or not using (n = 224) preoperative RAS inhibitors. A comparison of the two groups showed no significant differences in baseline parameters, including creatinine clearance, body mass index, history of diabetes and smoking, preoperative medicines (except that more patients with RAS inhibitors had a history of hypertension or congestive heart failure, fewer RAS inhibitor patients had chronic lung disease), in intraoperative perfusion and aortic cross-clamp time, and in postoperative complications and 30-d mortality. Multivariate logistic regression analysis demonstrated, however, that preoperative RAS inhibitors significantly and independently reduced the incidence of postoperative RF in the patients undergoing cardiac surgery compared with those not taking RAS inhibitors: 1.6% versus 7.6%, yielding an odds ratio of 0.19 (95 % CI 0.04-0.84, P = 0.029). Preoperative RAS inhibitors may have significant renoprotective effects for aging patients undergoing elective cardiac surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Emprego de sistemas robóticos na cirurgia cardiovascular Robotic systems in cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Roberto T. Sant'Anna

    2004-06-01

    Full Text Available O desenvolvimento de sistemas robóticos para cirurgia teve início na década de 80, por solicitação do exército norte-americano, que antevia a possibilidade de realizar operações em teatros de guerra, distantes do local onde estava o cirurgião. Entretanto, o primeiro uso em humanos só ocorreu anos mais tarde, numa ressecção transuretral de hiperplasia benigna de próstata. Cirurgiões cardíacos foram logo atraídos pela técnica robótica devido a possível aplicação com reduzido caráter invasivo; esperava-se menor trauma cirúrgico e redução da dor, morbidade, tempo de internação e custo do procedimento. Atualmente, de forma restrita e em casos selecionados, robôs são usados para revascularização do miocárdio e implante de marcapasso em cirurgias cardíacas totalmente endoscópicas; podendo também constituir apoio visual na retirada de artéria torácica interna, reconstrução valvar mitral e correção de defeitos congênitos. Utilizando o robô auxiliar AESOP® para controle do videotoracoscópio, com controle vocal por meio do sistema HERMES®, temos realizado dissecção da artéria torácica interna, implante de eletrodo ventricular esquerdo e abordagem de defeitos congênitos na cirurgia de correção. Apesar do entusiasmo científico inicial com a cirurgia robótica, ainda não existe evidência clara de superioridade desta técnica em relação à operação convencional, em termos de resultado. Isto se aplica também ao custo, pois o investimento inicial na aquisição de sistema cirúrgico completo (console, controle de vídeo, instrumental provavelmente é compensado após muitos procedimentos e longo intervalo. Mas é certo que a cirurgia robótica terá um lugar no futuro, possibilitando aprendizagem, telepresença e realização de procedimentos pouco invasivos, embora complexos.The development of robotic systems for surgery started in the 80's, motivated by the US army's need for surgical procedure in

  18. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  19. Comparison of the cable pin system with conventional open surgery for transverse patella fractures.

    Science.gov (United States)

    Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin

    2013-07-01

    The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  20. Postoperative cognitive dysfunction and neuroinflammation; Cardiac surgery and abdominal surgery are not the same

    NARCIS (Netherlands)

    Hovens, Iris B.; van Leeuwen, Barbara L.; Mariani, Massimo A.; Kraneveld, Aletta D.; Schoemaker, Regien G.

    Postoperative cognitive dysfunction (POCD) is a debilitating surgical complication, with cardiac surgery patients at particular risk. To gain insight in the mechanisms underlying the higher incidence of POCD after cardiac versus non-cardiac surgery, systemic and central inflammatory changes,

  1. A benefit-risk review of systemic haemostatic agents - Part 1 : In major surgery

    NARCIS (Netherlands)

    Fraser, Ian S.; Porte, Robert J.; Kouides, Peter A.; Lukes, Andrea S.

    2008-01-01

    Systemic haemostatic agents play an important role in the management of blood loss during major surgery where significant blood loss is likely and their use has increased in recent times as a consequence of demand for blood products outstripping supply and the risks associated with transfusions.

  2. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    Science.gov (United States)

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small

  3. Validation of risk assessment scoring systems for an audit of elective surgery for gastrointestinal cancer in elderly patients: an audit.

    Science.gov (United States)

    Wakabayashi, Hisao; Sano, Takanori; Yachida, Shinichi; Okano, Keiichi; Izuishi, Kunihiko; Suzuki, Yasuyuki

    2007-10-01

    The goal of this study was to validate the usefulness of risk assessment scoring systems for a surgical audit in elective digestive surgery for elderly patients. The validated scoring systems used were the Physiological and Operative Severity Score for enUmeration of Mortality and morbidity (POSSUM) and the Portsmouth predictor equation for mortality (P-POSSUM). This study involved 153 consecutive patients aged 75 years and older who underwent elective gastric or colorectal surgery between July 2004 and June 2006. A retrospective analysis was performed on data collected prior to each surgery. The predicted mortality and morbidity risks were calculated using each of the scoring systems and were used to obtain the observed/predicted (O/E) mortality and morbidity ratios. New logistic regression equations for morbidity and mortality were then calculated using the scores from the POSSUM system and applied retrospectively. The O/E ratio for morbidity obtained from POSSUM score was 0.23. The O/E ratios for mortality from the POSSUM score and the P-POSSUM were 0.15 and 0.38, respectively. Utilizing the new equations using scores from the POSSUM, the O/E ratio increased to 0.88. Both the POSSUM and P-POSSUM over-predicted the morbidity and mortality in elective gastrointestinal surgery for malignant tumors in elderly patients. However, if a surgical unit makes appropriate calculations using its own patient series and updates these equations, the POSSUM system can be useful in the risk assessment for surgery in elderly patients.

  4. Experiences from the Architectural Migration of a Joint Replacement Surgery Information System

    Directory of Open Access Journals (Sweden)

    Samuli Niiranen

    2008-01-01

    Full Text Available The goal of this study is to present the experiences gathered from the migration of an existing and deployed joint replacement surgery information system from a classical 2-tier architecture to a 4-tier architecture. These include discussion on the motivation for the migration and on the technical benefits of the chosen technical migration path and an evaluation of user experiences. The results from the analysis of clinical end-user and administrator experiences show an increase in the perceived performance and maintainability of the system and a high level of acceptance for the new system version.

  5. Surgery of the eloquent area using neuronavigation system

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira; Ono, Hidetoshi; Goto, Takumi; Aburano, Tamio [Asahikawa Medical Coll., Hokkaido (Japan)

    2001-03-01

    The purpose of this minimally invasive study was to evaluate the efficacy of a neuronavigation system for surgery of lesions near Broca's area, skull base, or paracentral sulcus. With regards to paracentral sulcus lesions, precise localization of the precentral gyrus was evaluated not only with preoperative 3D images of the brain but also confirmed by the combination of fMRI and intraoperative SEP. Using the neuronavigation system, Viewing Wand (ISG Technologies), three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus and skull representations obtained by MRI and CT. Six patients with lesions near Broca's area, 5 patients with skull base lesions, and 9 patients with lesions near the central sulcus were analyzed. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm, which was composed of repetition of rest-task every in 30 seconds for 150 seconds, in a 1.5-tesla echo-speed MR imager (Signa Horizon; General Electric Medical Systems, Milwaukee, WI). Statistical cross-correlation functional maps were generated and overlaid onto high-resolution anatomical MR images. Presurgical assessment of 3D reconstructed brain images were performed in all cases. They were analyzed in Broca's lesions, skull base lesions and paracentral sulcus lesions and were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. In fMRI, motor activation sites were obtained on both ipsilateral and contralateral hemispheres in all patients except for one patient with a hemorrhagic cyst. Locations of precentral gyri were predicted preoperatively. In all patients except for one case, fMRI was obtained even in tumor patient in whom intraoperative SEP was technically not feasible due to severe cortical brain damage from the paracentral tumor. The precentral gyri identified by 3D reconstructed brain images

  6. Does Prior Laparoscopic and Open Surgery Experience Have Any Impact on Learning Curve in Transition to Robotic Surgery?

    Directory of Open Access Journals (Sweden)

    Cüneyt Adayener

    2016-12-01

    Full Text Available It has been 15 years since the Food And Drug Administration approved the Da Vinci® robotic surgery system. Robotic applications are being used extensively in urology, particularly in radical prostatectomy. Like all high-tech products, this system also has a high cost and a steep learning curve, therefore, preventing it from becoming widespread. There are various studies on the effect of open surgery or laparoscopy experience on the learning curve of robotic surgery. Analyzing these interactions well will provide valuable information on making the training period of robotic system more efficient.

  7. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  8. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  9. Impact of radioguided occult lesion localization on the correct excision of malignant breast lesions. Effect of histology and tumor size

    International Nuclear Information System (INIS)

    Woll, J.P.P.; Garcia Vicente, A.M.; Gonzalez Garcia, B.; Delgado Portela, M.; Cordero Garcia, J.M.; Pardo Garcia, R.; Molino Trinidad, C.; Soriano Castrejon, A.M.; Cortes Romera, M.

    2011-01-01

    The aim of this study was to evaluate the impact of radioguided occult lesion localization (ROLL) in the correct location and excision of malignant breast lesions, and analyze if these results are affected by the histology and tumor size. A total of 105 patients with occult breast lesions were studied. The mean age was 55 years. An intralesional dose of 18.5 MBq of 99mTc-labeled macroaggregated human albumin (AMA) was administered using stereotaxic mammography or ultrasound. Surgical resection was carried out with the help of a gammadetector probe. In the histological study, disease-free margin was defined by a distance between the tumor lesion and the surgical margin of more than 1 mm. The possible influence of tumor histology and lesion diameter with respect to free/affected margins was analyzed. Correct radiotracer placement was achieved in 100/105 of the cases (95.2%). In the remaining 5 cases (4.8%), radiotracer placement was incorrect, with 2 of them being malignant lesions that were found by macroscopic inspection, and the other 3 having benign pathology. Among the malignant lesions (44 cases), correct placement of the radiotracer was achieved in 42 cases (95.5%). Of these 42 malignant lesions, in which the ROLL was correctly performed, free surgical margins were obtained in 24 cases (57.1%), while the other 18 (42.9%) had infiltrated surgical margins. The most common histological type among the malignant lesions was invasive ductal carcinoma (71.4%). The histological types with an increased frequency of infiltration of surgical margins were invasive and microinvasive cancer (94.4%). All the affected margins were in lesions greater than 10 mm, and the highest incidence was in those between 20 and 30 mm (55.5%). In our experience, the advantages of the ROLL technique are a precise localization of malignant breast lesions (95.5%) and an increased probability of a complete excision with free margins in more than one half of them. Nevertheless, special

  10. Comparative Study of 2D and 3D Optical Imaging Systems: Laparoendoscopic Single-Site Surgery in an Ex Vivo Model.

    Science.gov (United States)

    Vilaça, Jaime; Pinto, José Pedro; Fernandes, Sandra; Costa, Patrício; Pinto, Jorge Correia; Leão, Pedro

    2017-12-01

    Usually laparoscopy is performed by means of a 2-dimensional (2D) image system and multiport approach. To overcome the lack of depth perception, new 3-dimensional (3D) systems are arising with the added advantage of providing stereoscopic vision. To further reduce surgery-related trauma, there are new minimally invasive surgical techniques being developed, such as LESS (laparoendoscopic single-site) surgery. The aim of this study was to compare 2D and 3D laparoscopic systems in LESS surgical procedures. All participants were selected from different levels of experience in laparoscopic surgery-10 novices, 7 intermediates, and 10 experts were included. None of the participants had had previous experience in LESS surgery. Participants were chosen randomly to begin their experience with either the 2D or 3D laparoscopic system. The exercise consisted of performing an ex vivo pork cholecystectomy through a SILS port with the assistance of a fixed distance laparoscope. Errors, time, and participants' preference were recorded. Statistical analysis of time and errors between groups was conducted with a Student's t test (using independent samples) and the Mann-Whitney test. In all 3 groups, the average time with the 2D system was significantly reduced after having used the 3D system ( P 3D system. This study suggests that the 3D system may improve the learning curve and that learning from the 3D system is transferable to the 2D environment. Additionally, the majority of participants prefer 3D equipment.

  11. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  12. Robotic Gastric Bypass Surgery in the Swiss Health Care System: Analysis of Hospital Costs and Reimbursement.

    Science.gov (United States)

    Hagen, Monika E; Rohner, Peter; Jung, Minoa K; Amirghasemi, Nicolas; Buchs, Nicolas C; Fakhro, Jassim; Buehler, Leo; Morel, Philippe

    2017-08-01

    Robotic technology shows some promising early outcomes indicating potentially improved outcomes particularly for challenging bariatric procedures. Still, health care providers face significant clinical and economic challenges when introducing innovations. Prospectively derived administrative cost data of patients who were coded with a primary diagnosis of obesity (ICD-10 code E.66.X), a procedure of gastric bypass surgery (CHOP code 44.3), and a robotic identifier (CHOP codes 00.90.50 or 00.39) during the years 2012 to 2015 was analyzed and compared to the triggered reimbursement for this patient cohort. A total of 348 patients were identified. The mean number of diagnoses was 2.7 and the mean length of stay was 5.9 days. The overall mean cost per patients was Swiss Francs (CHF) from 2012 to 2014 that was 21,527, with a mean reimbursement of CHF 24,917. Cost of the surgery in 2015 was comparable to the previous years with CHF 22,550.0 (p = 0.6618), but reimbursement decreased significantly to CHF 20,499.0 (0.0001). The average cost for robotic gastric bypass surgery fell well below the average reimbursement within the Swiss DRG system between 2012 and 2014, and this robotic procedure was a DRG winner for that period. However, the Swiss DRG system has matured over the years with a significant decrease resulting in a deficit for robotic gastric bypass surgery in 2015. This stipulates a discussion as to how health care providers should continue offering robotic gastric bypass surgery, particularly in the light of developing clinical evidence.

  13. Urologic robotic surgery in Korea: past and present.

    Science.gov (United States)

    Seo, Ill Young

    2015-08-01

    Since 2005 when the da Vinci surgical system was approved as a medical device by the Korean Ministry of Health and Welfare, 51 systems have been installed in 40 institutions as of May 2015. Although robotic surgery is not covered by the national health insurance service in Korea, it has been used in several urologic fields as a less invasive surgery. Since the first robotic-assisted laparoscopic radical prostatectomy in 2005, partial nephrectomy, radical cystectomy, pyeloplasty, and other urologic surgeries have been performed. The following should be considered to extend the indications for robotic surgery: training systems including accreditation, operative outcomes from follow-up results, and cost-effectiveness. In this review, the history and current status of robotic surgeries in Korea are presented.

  14. Reconciliation of international administrative coding systems for comparison of colorectal surgery outcome.

    Science.gov (United States)

    Munasinghe, A; Chang, D; Mamidanna, R; Middleton, S; Joy, M; Penninckx, F; Darzi, A; Livingston, E; Faiz, O

    2014-07-01

    Significant variation in colorectal surgery outcomes exists between different countries. Better understanding of the sources of variable outcomes using administrative data requires alignment of differing clinical coding systems. We aimed to map similar diagnoses and procedures across administrative coding systems used in different countries. Administrative data were collected in a central database as part of the Global Comparators (GC) Project. In order to unify these data, a systematic translation of diagnostic and procedural codes was undertaken. Codes for colorectal diagnoses, resections, operative complications and reoperative interventions were mapped across the respective national healthcare administrative coding systems. Discharge data from January 2006 to June 2011 for patients who had undergone colorectal surgical resections were analysed to generate risk-adjusted models for mortality, length of stay, readmissions and reoperations. In all, 52 544 case records were collated from 31 institutions in five countries. Mapping of all the coding systems was achieved so that diagnosis and procedures from the participant countries could be compared. Using the aligned coding systems to develop risk-adjusted models, the 30-day mortality rate for colorectal surgery was 3.95% (95% CI 0.86-7.54), the 30-day readmission rate was 11.05% (5.67-17.61), the 28-day reoperation rate was 6.13% (3.68-9.66) and the mean length of stay was 14 (7.65-46.76) days. The linkage of international hospital administrative data that we developed enabled comparison of documented surgical outcomes between countries. This methodology may facilitate international benchmarking. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  15. Surgery with cooperative robots.

    Science.gov (United States)

    Lehman, Amy C; Berg, Kyle A; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Rentschler, Mark E; Platt, Stephen R; Farritor, Shane M; Oleynikov, Dmitry

    2008-03-01

    Advances in endoscopic techniques for abdominal procedures continue to reduce the invasiveness of surgery. Gaining access to the peritoneal cavity through small incisions prompted the first significant shift in general surgery. The complete elimination of external incisions through natural orifice access is potentially the next step in reducing patient trauma. While minimally invasive techniques offer significant patient advantages, the procedures are surgically challenging. Robotic surgical systems are being developed that address the visualization and manipulation limitations, but many of these systems remain constrained by the entry incisions. Alternatively, miniature in vivo robots are being developed that are completely inserted into the peritoneal cavity for laparoscopic and natural orifice procedures. These robots can provide vision and task assistance without the constraints of the entry incision, and can reduce the number of incisions required for laparoscopic procedures. In this study, a series of minimally invasive animal-model surgeries were performed using multiple miniature in vivo robots in cooperation with existing laparoscopy and endoscopy tools as well as the da Vinci Surgical System. These procedures demonstrate that miniature in vivo robots can address the visualization constraints of minimally invasive surgery by providing video feedback and task assistance from arbitrary orientations within the peritoneal cavity.

  16. Improving Quality in Colorectal Surgery

    NARCIS (Netherlands)

    J.C. Slieker (Juliette)

    2014-01-01

    markdownabstract__Abstract__ Colorectal surgery is an important aspect of our current health system, due to the high incidence of colorectal cancer combined with an ageing population, improved long-term outcomes after colorectal surgery, and the perfectioning of the operative and postoperative

  17. Robotics in Colorectal Surgery

    Science.gov (United States)

    Weaver, Allison; Steele, Scott

    2016-01-01

    Over the past few decades, robotic surgery has developed from a futuristic dream to a real, widely used technology. Today, robotic platforms are used for a range of procedures and have added a new facet to the development and implementation of minimally invasive surgeries. The potential advantages are enormous, but the current progress is impeded by high costs and limited technology. However, recent advances in haptic feedback systems and single-port surgical techniques demonstrate a clear role for robotics and are likely to improve surgical outcomes. Although robotic surgeries have become the gold standard for a number of procedures, the research in colorectal surgery is not definitive and more work needs to be done to prove its safety and efficacy to both surgeons and patients. PMID:27746895

  18. Vitreoretinal complications and vitreoretinal surgery in osteo-odonto-keratoprosthesis surgery.

    Science.gov (United States)

    Lim, Laurence S; Ang, Chong Lye; Wong, Edmund; Wong, Doric W K; Tan, Donald T H

    2014-02-01

    To describe the indications for and approaches to vitreoretinal surgery in patients with osteo-odonto-keratoprosthesis (OOKP). Retrospective case series. This was a retrospective review of all patients who had undergone OOKP surgery between 2003 and 2012 at our center. OOKP procedures were performed for severe ocular surface disease according to the indications and techniques described in the patient demographics of the Rome-Vienna Protocol. Indications for retinal surgery, surgical outcomes, and intraoperative and postoperative complications were documented. Operative techniques were reviewed from the surgical records, and any subsequent surgeries were also recorded. Thirty-six patients underwent OOKP, and retinal surgery was indicated in 13 (36%). The indications for and approaches to surgery were retinal detachment repair using an Eckardt temporary keratoprosthesis; assessment of retina and optic nerve health prior to OOKP surgery, using either a temporary keratoprosthesis or an endoscope; endoscopic cyclophotocoagulation for intractable glaucoma; endoscopic trimming of a retroprosthetic membrane; or vitrectomy for endophthalmitis with visualization through the OOKP optic using the binocular indirect viewing system. In all cases, retinal surgical aims were achieved with a single procedure. Postoperative vitreous hemorrhage occurred in 16 patients (44%), but all resolved spontaneously. OOKPs represent the last hope for restoration of vision in severe ocular surface disease, and the retinal surgeon is frequently called upon in the assessment and management of these patients. Temporary keratoprostheses and endoscopic vitrectomies are valuable surgical tools in these challenging cases, improving functional outcomes without compromising OOKP success. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Operation and force analysis of the guide wire in a minimally invasive vascular interventional surgery robot system

    Science.gov (United States)

    Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian

    2015-03-01

    To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.

  20. [Thromboelastography and its use in cardiac surgery].

    Science.gov (United States)

    Ak, Koray; Atalan, Nazan; Tekeli, Atike; Işbir, Selim; Civelek, Ali; Emekli, Nesrin; Arsan, Sinan

    2008-04-01

    Thromboelastography is an alternative method to conventional coagulation tests for the general evaluation of hemostatic system. Cardiac surgery with cardiopulmonary bypass is accomplished by complex alterations of hemostasis, including acquired dysfunction of platelets, consumption coagulopathy and increased fibrinolysis. Despite major advances in blood conservation methods and perioperative care of the patients, transfusion rates in cardiac surgery remain high. Thromboelastography has an ability to assess almost all components of haemostatic system globally. Currently, thromboelastography is used with standard coagulation tests to decrease the microvascular bleeding and homologous blood transfusion in cardiac surgery with cardiopulmonary bypass. In this review, we aimed to discuss thromboelastography technology and its usage in cardiac surgery.

  1. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...... affect the overall latency. To measure the photon-to-photon latency, we used a microcontroller to determine the time between the activation of a lightemitting diode in front of the endoscopic camera and the corresponding increase in intensity of the surgeon's display as measured by a phototransistor...

  2. Effect of Roux-en-Y Bariatric Surgery on Lipoproteins, Insulin Resistance, and Systemic and Vascular Inflammation in Obesity and Diabetes

    Directory of Open Access Journals (Sweden)

    Rahul Yadav

    2017-11-01

    Full Text Available PurposeObesity is a major modifiable risk factor for cardiovascular disease. Bariatric surgery is considered to be the most effective treatment option for weight reduction in obese patients with and without type 2 diabetes (T2DM.ObjectiveTo evaluate changes in lipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction following Roux-en-Y bariatric surgery in obese patients with and without diabetes.Materials and methodsLipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction were measured in 37 obese patients with (n = 17 and without (n = 20 T2DM, before and 6 and 12 months after Roux-en-Y bariatric surgery. Two way between subject ANOVA was carried out to study the interaction between independent variables (time since surgery and presence of diabetes and all dependent variables.ResultsThere was a significant effect of time since surgery on (large effect size weight, body mass index (BMI, waist circumference, triglycerides (TG, small-dense LDL apolipoprotein B (sdLDL ApoB, HOMA-IR, CRP, MCP-1, ICAM-1, E-selectin, P-selectin, leptin, and adiponectin. BMI and waist circumference had the largest impact of time since surgery. The effect of time since surgery was noticed mostly in the first 6 months. Absence of diabetes led to a significantly greater reduction in total cholesterol, low-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol although the effect size was small to medium. There was a greater reduction in TG and HOMA-IR in patients with diabetes with a small effect size. No patients were lost to follow up.ConclusionLipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction improve mostly 6 months after bariatric surgery in obese patients with and without diabetes.Clinical Trial Registrationwww.ClinicalTrials.gov, identifier: NCT02169518. https

  3. Technological advances in robotic-assisted laparoscopic surgery.

    Science.gov (United States)

    Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K

    2009-05-01

    In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.

  4. [Gases in vitreoretinal surgery].

    Science.gov (United States)

    Janco, L; Vida, R; Bartos, M; Villémová, K; Izák, M

    2012-02-01

    To evaluate the importance and benefits of using gases in vitreoretinal surgery. The gases represent a wide group of substances used in eye surgery for more than 100 years. The role of intraocular gases in vitreoretinal surgery is irreplaceable. Their use is still considered to be the "gold standard". An important step in eye surgery was the introduction of expanding gases--sulfur hexafluoride and perfluorocarbons into routine clinical practice. The most common indications for the use of intraocular gases are: retinal detachment, idiopathic macular hole, complications of vitreoretinal surgery and others. The introduction of intraocular gases into routine clinical practice, along with other modern surgical techniques resulted in significant improvement of postoperative outcomes in a wide range of eye diseases. Understanding the principles of intraocular gases use brings the benefits to the patient and physician as well. Due to their physical and chemical properties they pose far the best and most appropriate variant of intraocular tamponade. Gases also bring some disadvantages, such as difficulties in detailed fundus examination, visual acuity testing, ultrasonographic examination, difficulties in application of intravitreal drugs or reduced possibility of retina laser treatment. The gases significantly change optical system properties of the eye. The use of gases in vitreoretinal surgery has significantly increased success rate of retinal detachment surgery, complicated posterior segment cases, trauma, surgery of the macula and other diseases.

  5. Development and validation of a tool for non-technical skills evaluation in robotic surgery-the ICARS system.

    Science.gov (United States)

    Raison, Nicholas; Wood, Thomas; Brunckhorst, Oliver; Abe, Takashige; Ross, Talisa; Challacombe, Ben; Khan, Mohammed Shamim; Novara, Giacomo; Buffi, Nicolo; Van Der Poel, Henk; McIlhenny, Craig; Dasgupta, Prokar; Ahmed, Kamran

    2017-12-01

    Non-technical skills (NTS) are being increasingly recognised as vital for safe surgical practice. Numerous NTS rating systems have been developed to support effective training and assessment. Yet despite the additional challenges posed by robotic surgery, no NTS rating systems have been developed for this unique surgical environment. This study reports the development and validation of the first NTS behavioural rating system for robotic surgery. A comprehensive index of all relevant NTS behaviours in robotic surgery was developed through observation of robotic theatre and interviews with robotic surgeons. Using a Delphi methodology, a panel of 16 expert surgeons was consulted to identify behaviours important to NTS assessment. These behaviours were organised into an appropriate assessment template. Experts were consulted on the feasibility, applicability and educational impact of ICARS. An observational trial was used to validate ICARS. 73 novice, intermediate and expert robotic surgeons completed a urethrovesical anastomosis within a simulated operating room. NTS were tested using four scripted scenarios of increasing difficulty. Performances were video recorded. Robotic and NTS experts assessed the videos post hoc using ICARS and the standard behavioural rating system, NOn-Technical Skills for Surgeons (NOTSS). 28 key non-technical behaviours were identified by the expert panel. The finalised behavioural rating system was organised into four principle domains and seven categories. Expert opinion strongly supported its implementation. ICARS was found to be equivalent to NOTSS on Bland-Altman analysis and accurately differentiated between novice, intermediate and expert participants, p = 0.01. Moderate agreement was found between raters, Krippendorff's alpha = 0.4. The internal structure of ICARS was shown to be consistent and reliable (median Cronbach alpha = 0.92, range 0.85-0.94). ICARS is the first NTS behavioural rating system developed for robotic

  6. A comparative cost analysis of robotic-assisted surgery versus laparoscopic surgery and open surgery: the necessity of investing knowledgeably.

    Science.gov (United States)

    Tedesco, Giorgia; Faggiano, Francesco C; Leo, Erica; Derrico, Pietro; Ritrovato, Matteo

    2016-11-01

    Robotic surgery has been proposed as a minimally invasive surgical technique with advantages for both surgeons and patients, but is associated with high costs (installation, use and maintenance). The Health Technology Assessment Unit of the Bambino Gesù Children's Hospital sought to investigate the economic sustainability of robotic surgery, having foreseen its impact on the hospital budget METHODS: Break-even and cost-minimization analyses were performed. A deterministic approach for sensitivity analysis was applied by varying the values of parameters between pre-defined ranges in different scenarios to see how the outcomes might differ. The break-even analysis indicated that at least 349 annual interventions would need to be carried out to reach the break-even point. The cost-minimization analysis showed that robotic surgery was the most expensive procedure among the considered alternatives (in terms of the contribution margin). Robotic surgery is a good clinical alternative to laparoscopic and open surgery (for many pediatric operations). However, the costs of robotic procedures are higher than the equivalent laparoscopic and open surgical interventions. Therefore, in the short run, these findings do not seem to support the decision to introduce a robotic system in our hospital.

  7. Laser assisted robotic surgery in cornea transplantation

    Science.gov (United States)

    Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo

    2017-03-01

    Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.

  8. The R.I.R.S. scoring system: An innovative scoring system for predicting stone-free rate following retrograde intrarenal surgery.

    Science.gov (United States)

    Xiao, Yinglong; Li, Deng; Chen, Lei; Xu, Yaoting; Zhang, Dingguo; Shao, Yi; Lu, Jun

    2017-11-21

    To establish and internally validate an innovative R.I.R.S. scoring system that allows urologists to preoperatively estimate the stone-free rate (SFR) after retrograde intrarenal surgery (RIRS). This study included 382 eligible samples from a total 573 patients who underwent RIRS from January 2014 to December 2016. Four reproducible factors in the R.I.R.S. scoring system, including renal stone density, inferior pole stone, renal infundibular length and stone burden, were measured based on preoperative computed tomography of urography to evaluate the possibility of stone clearance after RIRS. The median cumulative diameter of the stones was 14 mm, and the interquartile range was 10 to 21. The SFR on postoperative day 1 in the present cohort was 61.5% (235 of 382), and the final SFR after 1 month was 73.6% (281 of 382). We established an innovative scoring system to evaluate SFR after RIRS using four preoperative characteristics. The range of the R.I.R.S. scoring system was 4 to 10. The overall score showed a great significance of stone-free status (p R.I.R.S. scoring system was 0.904. The R.I.R.S. scoring system is associated with SFR after RIRS. This innovative scoring system can preoperatively assess treatment success after intrarenal surgery and can be used for preoperative surgical arrangement and comparisons of outcomes among different centers and within a center over time.

  9. Age and other perioperative risk factors for postoperative systemic inflammatory response syndrome after cardiac surgery

    NARCIS (Netherlands)

    Dieleman, J. M.; Peelen, L. M.; Coulson, T. G.; Tran, L.; Reid, C. M.; Smith, Jennifer A.; Myles, P. S.; Pilcher, C.D.

    2017-01-01

    Background The inflammatory response to surgery varies considerably between individual patients. Age might be a substantial factor in this variability. Our objective was to examine the association of patient age and other potential risk factors with the occurrence of a postoperative systemic

  10. Mortality after surgery in Europe

    DEFF Research Database (Denmark)

    Pearse, Rupert M; Moreno, Rui P; Bauer, Peter

    2012-01-01

    Clinical outcomes after major surgery are poorly described at the national level. Evidence of heterogeneity between hospitals and health-care systems suggests potential to improve care for patients but this potential remains unconfirmed. The European Surgical Outcomes Study was an international...... study designed to assess outcomes after non-cardiac surgery in Europe....

  11. Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2016-03-01

    Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.

  12. [Advantages and disadvantages of minimally invasive surgery in colorectal cancer surgery].

    Science.gov (United States)

    Zheng, Minhua; Ma, Junjun

    2017-06-25

    Since the emergence of minimally invasive technology twenty years ago, as a surgical concept and surgical technique for colorectal cancer surgery, its obvious advantages have been recognized. Laparoscopic technology, as one of the most important technology platform, has got a lot of evidence-based support for the oncological safety and effectiveness in colorectal cancer surgery Laparoscopic technique has advantages in terms of identification of anatomic plane and autonomic nerve, protection of pelvic structure, and fine dissection of vessels. But because of the limitation of laparoscopic technology there are still some deficiencies and shortcomings, including lack of touch and lack of stereo vision problems, in addition to the low rectal cancer, especially male, obese, narrow pelvis, larger tumors, it is difficult to get better view and manipulating triangle in laparoscopy. However, the emergence of a series of new minimally invasive technology platform is to make up for the defects and deficiencies. The robotic surgical system possesses advantages, such as stereo vision, higher magnification, manipulator wrist with high freedom degree, filtering of tremor and higher stability, but still has disadvantages, such as lack of haptic feedback, longer operation time, high operation cost and expensive price. 3D system of laparoscopic surgery has similar visual experience and feelings as robotic surgery in the 3D view, the same operating skills as 2D laparoscopy and a short learning curve. The price of 3D laparoscopy is also moderate, which makes the 3D laparoscopy more popular in China. Transanal total mesorectal excision (taTME) by changing the traditional laparoscopic pelvic surgery approach, may have certain advantages for male cases with narrow pelvic and patients with large tumor, and it is in accordance with the technical concept of natural orifice, with less minimally invasive and better cosmetics, which can be regarded as a supplemental technique of the

  13. Surgery applications of virtual reality

    Science.gov (United States)

    Rosen, Joseph

    1994-01-01

    Virtual reality is a computer-generated technology which allows information to be displayed in a simulated, bus lifelike, environment. In this simulated 'world', users can move and interact as if they were actually a part of that world. This new technology will be useful in many different fields, including the field of surgery. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations, simulate and perform surgical procedures (telesurgery), and predict the outcomes of surgery. The authors of this paper describe the basic components of a virtual reality surgical system. These components include: the virtual world, the virtual tools, the anatomical model, the software platform, the host computer, the interface, and the head-coupled display. In the chapter they also review the progress towards using virtual reality for surgical training, planning, telesurgery, and predicting outcomes. Finally, the authors present a training system being developed for the practice of new procedures in abdominal surgery.

  14. Bariatric surgery and the changing current scope of general surgery practice: implications for general surgery residency training.

    Science.gov (United States)

    Mostaedi, Rouzbeh; Ali, Mohamed R; Pierce, Jonathan L; Scherer, Lynette A; Galante, Joseph M

    2015-02-01

    The scope of general surgery practice has evolved tremendously in the last 20 years. However, clinical experience in general surgery residency training has undergone relatively little change. To evaluate the current scope of academic general surgery and its implications on surgical residency. The University HealthSystem Consortium and Association of American Medical Colleges established the Faculty Practice Solution Center (FPSC) to characterize physician productivity. The FPSC is a benchmarking tool for academic medical centers created from revenue data collected from more than 90,000 physicians who practice at 95 institutions across the United States. The FPSC database was queried to evaluate the annual mean procedure frequency per surgeon (PFS) in each calendar year from 2006 through 2011. The associated work relative value units (wRVUs) were also examined to measure physician effort and skill. During the 6-year period, 146 distinct Current Procedural Terminology codes were among the top 100 procedures, and 16 of these procedures ranked in the top 10 procedures in at least 1 year. The top 10 procedures accounted for more than half (range, 52.5%-57.2%) of the total 100 PFS evaluated for each year. Laparoscopic Roux-en-Y gastric bypass was consistently among the top 10 procedures in each year (PFS, 18.2-24.6). The other most frequently performed procedures included laparoscopic cholecystectomy (PFS, 30.3-43.5), upper gastrointestinal tract endoscopy (PFS, 26.5-34.3), mastectomy (PFS, 16.5-35.0), inguinal hernia repair (PFS, 15.5-22.1), and abdominal wall hernia repair (PFS, 21.6-26.1). In all years, laparoscopic Roux-en-Y gastric bypass generated the highest number of wRVUs (wRVUs, 491.0-618.2), and laparoscopic cholecystectomy was regularly the next highest (wRVUs, 335.8-498.7). A significant proportion of academic general surgery is composed of bariatric surgery, yet surgical training does not sufficiently emphasize the necessary exposure to technical expertise

  15. Critical differences between elective and emergency surgery: identifying domains for quality improvement in emergency general surgery.

    Science.gov (United States)

    Columbus, Alexandra B; Morris, Megan A; Lilley, Elizabeth J; Harlow, Alyssa F; Haider, Adil H; Salim, Ali; Havens, Joaquim M

    2018-04-01

    The objective of our study was to characterize providers' impressions of factors contributing to disproportionate rates of morbidity and mortality in emergency general surgery to identify targets for care quality improvement. Emergency general surgery is characterized by a high-cost burden and disproportionate morbidity and mortality. Factors contributing to these observed disparities are not comprehensively understood and targets for quality improvement have not been formally developed. Using a grounded theory approach, emergency general surgery providers were recruited through purposive-criterion-based sampling to participate in semi-structured interviews and focus groups. Participants were asked to identify contributors to emergency general surgery outcomes, to define effective care for EGS patients, and to describe operating room team structure. Interviews were performed to thematic saturation. Transcripts were iteratively coded and analyzed within and across cases to identify emergent themes. Member checking was performed to establish credibility of the findings. A total of 40 participants from 5 academic hospitals participated in either individual interviews (n = 25 [9 anesthesia, 12 surgery, 4 nursing]) or focus groups (n = 2 [15 nursing]). Emergency general surgery was characterized by an exceptionally high level of variability, which can be subcategorized as patient-variability (acute physiology and comorbidities) and system-variability (operating room resources and workforce). Multidisciplinary communication is identified as a modifier to variability in emergency general surgery; however, nursing is often left out of early communication exchanges. Critical variability in emergency general surgery may impact outcomes. Patient-variability and system-variability, with focus on multidisciplinary communication, represent potential domains for quality improvement in this field. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: A systemic review.

    Science.gov (United States)

    Fiani, Brian; Quadri, Syed A; Farooqui, Mudassir; Cathel, Alessandra; Berman, Blake; Noel, Jerry; Siddiqi, Javed

    2018-04-03

    Whenever any new technology is introduced into the healthcare system, it should satisfy all three pillars of the iron triangle of health care, which are quality, cost-effectiveness, and accessibility. There has been quite advancement in the field of spine surgery in the last two decades with introduction of new technological modalities such as CAN and surgical robotic devices. MAZOR SpineAssist/Renaissance was the first robotic system to be approved for the use in spine surgeries in the USA in 2004. In this review, the authors sought to determine if the current literature supports this technology to be cost-effective, accessible, and improve the quality of care for individuals and populations by increasing the likelihood of desired health outcomes. Robotic-assisted surgery seems to provide perfection in surgical ergonomics and surgical dexterity, consequently improving patient outcomes. A lot of data is present on the accuracy, effectiveness, and safety of the robotic-guided technology which reflects remarkable improvements in quality of care, making its utility convincingly undisputable. The technology has been claimed to be cost-effective but there seems to be lack of data in the literature on this topic to validate this claim. Apart from just the outcome parameters, there is an immense need of studies on real-time cost-efficacy, patient perspective, surgeon and resident learning curve, and their experience with this new technology. Furthermore, new studies looking into increased utilities of this technology, such as brain and spine tumor resection, deep brain stimulation procedures, and osteotomies in deformity surgery, might authenticate the cost of the equipment.

  17. Effects of Topical Phenylephrine HCl 2.5% used before Cataract Surgery on Systemic Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emre Ayıntap

    2011-06-01

    Full Text Available Purpose: To evaluate the effect of topical phenylephrine HCl 2.5% (Mydfrin, used as a fast and effective mydriatic before cataract surgery, on systemic blood pressure. Material and Method: Topical phenylephrine HCl 2.5% was administered 3 times with 5-minute intervals before cataract surgery to 44 eyes of 44 patients. The systemic blood pressure was measured preoperatively and at 15 and 30 minutes. Results: The mean systolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 119.7mmHg, while 15 and 30 minutes later, it was 125.3 mmHg and 121.2 mmHg, respectively. The mean diastolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 75.9 mmHg; 15 and 30 minutes later, it was 76.9 mmHg and 75.3 mmHg, respectively. The increase in systolic blood pressure at 15 and 30 minutes was statistically significant (p=0.003 and p=0.042. The change in diastolic blood pressure was not statistically significant. Discussion: Phenylephrine HCl 2.5%, which is used preoperatively as a fast and effective mydriatic for cataract surgery, can increase the systolic blood pressure. This effect is most significant at 15 minutes and lasts at least 30 minutes. This agent should be used with care in hypertensive patients. (Turk J Ophthalmol 2011; 41: 164-6

  18. Virtual skeletal complex model- and landmark-guided orthognathic surgery system.

    Science.gov (United States)

    Lee, Sang-Jeong; Woo, Sang-Yoon; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Han, Jeong Joon; Yang, Hoon Joo; Hwang, Soon Jung; Yi, Won-Jin

    2016-05-01

    In this study, correction of the maxillofacial deformities was performed by repositioning bone segments to an appropriate location according to the preoperative planning in orthognathic surgery. The surgery was planned using the patient's virtual skeletal models fused with optically scanned three-dimensional dentition. The virtual maxillomandibular complex (MMC) model of the patient's final occlusal relationship was generated by fusion of the maxillary and mandibular models with scanned occlusion. The final position of the MMC was simulated preoperatively by planning and was used as a goal model for guidance. During surgery, the intraoperative registration was finished immediately using only software processing. For accurate repositioning, the intraoperative MMC model was visualized on the monitor with respect to the simulated MMC model, and the intraoperative positions of multiple landmarks were also visualized on the MMC surface model. The deviation errors between the intraoperative and the final positions of each landmark were visualized quantitatively. As a result, the surgeon could easily recognize the three-dimensional deviation of the intraoperative MMC state from the final goal model without manually applying a pointing tool, and could also quickly determine the amount and direction of further MMC movements needed to reach the goal position. The surgeon could also perform various osteotomies and remove bone interference conveniently, as the maxillary tracking tool could be separated from the MMC. The root mean square (RMS) difference between the preoperative planning and the intraoperative guidance was 1.16 ± 0.34 mm immediately after repositioning. After surgery, the RMS differences between the planning and the postoperative computed tomographic model were 1.31 ± 0.28 mm and 1.74 ± 0.73 mm for the maxillary and mandibular landmarks, respectively. Our method provides accurate and flexible guidance for bimaxillary orthognathic surgery based on

  19. Robotic general surgery: current practice, evidence, and perspective.

    Science.gov (United States)

    Jung, M; Morel, P; Buehler, L; Buchs, N C; Hagen, M E

    2015-04-01

    Robotic technology commenced to be adopted for the field of general surgery in the 1990s. Since then, the da Vinci surgical system (Intuitive Surgical Inc, Sunnyvale, CA, USA) has remained by far the most commonly used system in this domain. The da Vinci surgical system is a master-slave machine that offers three-dimensional vision, articulated instruments with seven degrees of freedom, and additional software features such as motion scaling and tremor filtration. The specific design allows hand-eye alignment with intuitive control of the minimally invasive instruments. As such, robotic surgery appears technologically superior when compared with laparoscopy by overcoming some of the technical limitations that are imposed on the surgeon by the conventional approach. This article reviews the current literature and the perspective of robotic general surgery. While robotics has been applied to a wide range of general surgery procedures, its precise role in this field remains a subject of further research. Until now, only limited clinical evidence that could establish the use of robotics as the gold standard for procedures of general surgery has been created. While surgical robotics is still in its infancy with multiple novel systems currently under development and clinical trials in progress, the opportunities for this technology appear endless, and robotics should have a lasting impact to the field of general surgery.

  20. Efficacy of an Intra-Operative Imaging Software System for Anatomic Anterior Cruciate Ligament Reconstruction Surgery

    Directory of Open Access Journals (Sweden)

    Xudong Zhang

    2012-01-01

    Full Text Available An imaging software system was studied for improving the performance of anatomic anterior cruciate ligament (ACL reconstruction which requires identifying ACL insertion sites for bone tunnel placement. This software predicts and displays the insertion sites based on the literature data and patient-specific bony landmarks. Twenty orthopaedic surgeons performed simulated arthroscopic ACL surgeries on 20 knee specimens, first without and then with the visual guidance by fluoroscopic imaging, and their tunnel entry positions were recorded. The native ACL insertion morphologies of individual specimens were quantified in relation to CT-based bone models and then used to evaluate the software-generated insertion locations. Results suggested that the system was effective in leading surgeons to predetermined locations while the application of averaged insertion morphological information in individual surgeries can be susceptible to inaccuracy and uncertainty. Implications on challenges associated with developing engineering solutions to aid in re-creating or recognizing anatomy in surgical care delivery are discussed.

  1. Robotic Applications in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alan P. Kypson

    2008-11-01

    Full Text Available Traditionally, cardiac surgery has been performed through a median sternotomy, which allows the surgeon generous access to the heart and surrounding great vessels. As a paradigm shift in the size and location of incisions occurs in cardiac surgery, new methods have been developed to allow the surgeon the same amount of dexterity and accessibility to the heart in confined spaces and in a less invasive manner. Initially, long instruments without pivot points were used, however, more recent robotic telemanipulation systems have been applied that allow for improved dexterity, enabling the surgeon to perform cardiac surgery from a distance not previously possible. In this rapidly evolving field, we review the recent history and clinical results of using robotics in cardiac surgery.

  2. Information technology in the strategy of digestive surgery. (2) Advances of CAD system using OsiriX

    International Nuclear Information System (INIS)

    Sugimoto, Maki; Yasuda, Hideki; Koda, Keiji; Yamazaki, Masato; Tezuka, Tohru; Kosugi, Chihiro; Watayo, Yoshihisa; Naka, Shuji

    2007-01-01

    OsiriX, one of information technology (IT) product in medicine, is an image processing system developed by surgeons and its software for Mac OS can be installed free of charge (http://homepage.mac.com/rossetantoine/osrix/). The present review describes the practical application of this computer-aided diagnostic (CAD) tool mainly in the field of surgery of hepato-biliary-pancreatic system. Authors are successfully utilizing the OsiriX for pre-operative diagnosis by modalities of multidetector-row CT (MDCT), MRI and PET images, for simulation of surgery by volume rendering, carbon dioxide MDCT cholangiopancreatography (CMCP), 3D vascular construction MDCT angiography and virtual reality, and for navigation during the actual operation. The machine they use is 16-row MDCT LightSpeed Ultra 16 (GE Healthcare), and their data are processed through the Digital Imaging and Communications in Medicine (DICOM) viewer OsiriX 2.6, Power Mac G5, MacBook Pro (Apple Computer, Inc.) and 3D image processing engine (TeraRecon, Inc.). Presented are details of decision of region of interest (ROI), 3D ROI extraction by region-growing, MacBook Pro and iPod, and IT surgery by OsiriX, which are still being improved day by day. (T.I.)

  3. Robotic technology in surgery: current status in 2008.

    Science.gov (United States)

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  4. Metabolic phenotype-microRNA data fusion analysis of the systemic consequences of Roux-en-Y gastric bypass surgery.

    OpenAIRE

    Wu, Q; Li, JV; Seyfried, F; le Roux, CW; Ashrafian, H; Athanasiou, T; Fenske, W; Darzi, A; Nicholson, JK; Holmes, E; Gooderham, NJ

    2015-01-01

    Background/Objectives: Bariatric surgery offers sustained marked weight loss and often remission of type 2 diabetes, yet the mechanisms of establishment of these health benefits are not clear. Subjects/Methods: We mapped the coordinated systemic responses of gut hormones, the circulating miRNAome and the metabolome in a rat model of Roux-en-Y gastric bypass (RYGB) surgery. Results: The response of circulating microRNAs (miRNAs) to RYGB was striking and selective. Analysis of 14 significantly ...

  5. Robot-Assisted Fracture Surgery: Surgical Requirements and System Design.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2018-03-09

    The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.

  6. Surgical outcomes of robot-assisted rectal cancer surgery using the da Vinci Surgical System: a multi-center pilot Phase II study.

    Science.gov (United States)

    Tsukamoto, Shunsuke; Nishizawa, Yuji; Ochiai, Hiroki; Tsukada, Yuichiro; Sasaki, Takeshi; Shida, Dai; Ito, Masaaki; Kanemitsu, Yukihide

    2017-12-01

    We conducted a multi-center pilot Phase II study to examine the safety of robotic rectal cancer surgery performed using the da Vinci Surgical System during the introduction period of robotic rectal surgery at two institutes based on surgical outcomes. This study was conducted with a prospective, multi-center, single-arm, open-label design to assess the safety and feasibility of robotic surgery for rectal cancer (da Vinci Surgical System). The primary endpoint was the rate of adverse events during and after robotic surgery. The secondary endpoint was the completion rate of robotic surgery. Between April 2014 and July 2016, 50 patients were enrolled in this study. Of these, 10 (20%) had rectosigmoid cancer, 17 (34%) had upper rectal cancer, and 23 (46%) had lower rectal cancer; six underwent high anterior resection, 32 underwent low anterior resection, 11 underwent intersphincteric resection, and one underwent abdominoperineal resection. Pathological stages were Stage 0 in 1 patient, Stage I in 28 patients, Stage II in 7 patients and Stage III in 14 patients. Pathologically complete resection was achieved in all patients. There was no intraoperative organ damage or postoperative mortality. Eight (16%) patients developed complications of all grades, of which 2 (4%) were Grade 3 or higher, including anastomotic leakage (2%) and conversion to open surgery (2%). The present study demonstrates the feasibility and safety of robotic rectal cancer surgery, as reflected by low morbidity and low conversion rates, during the introduction period. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. An early validation of the Society for Vascular Surgery lower extremity threatened limb classification system.

    Science.gov (United States)

    Cull, David L; Manos, Ginger; Hartley, Michael C; Taylor, Spence M; Langan, Eugene M; Eidt, John F; Johnson, Brent L

    2014-12-01

    The Society for Vascular Surgery (SVS) recently established the Lower Extremity Threatened Limb Classification System, a staging system using Wound characteristic, Ischemia, and foot Infection (WIfI) to stratify the risk for limb amputation at 1 year. Although intuitive in nature, this new system has not been validated. The purpose of the following study was to determine whether the WIfI system is predictive of limb amputation and wound healing. Between 2007 and 2010, we prospectively obtained data related to wound characteristics, extent of infection, and degree of postrevascularization ischemia in 139 patients with foot wounds who presented for lower extremity revascularization (158 revascularization procedures). After adapting those data to the WIfI classifications, we analyzed the influence of wound characteristics, extent of infection, and degree of ischemia on time to wound healing; empirical Kaplan-Meier survival curves were compared with theoretical outcomes predicted by WIfI expert consensus opinion. Of the 158 foot wounds, 125 (79%) healed. The median time to wound healing was 2.7 months (range, 1-18 months). Factors associated with wound healing included presence of diabetes mellitus (P = .013), wound location (P = .049), wound size (P = .007), wound depth (P = .004), and degree of ischemia (P valid. Further validation of the WIfI classification system with multicenter data is justified. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. A novel risk classification system for 30-day mortality in children undergoing surgery

    Science.gov (United States)

    Walter, Arianne I.; Jones, Tamekia L.; Huang, Eunice Y.; Davis, Robert L.

    2018-01-01

    A simple, objective and accurate way of grouping children undergoing surgery into clinically relevant risk groups is needed. The purpose of this study, is to develop and validate a preoperative risk classification system for postsurgical 30-day mortality for children undergoing a wide variety of operations. The National Surgical Quality Improvement Project-Pediatric participant use file data for calendar years 2012–2014 was analyzed to determine preoperative variables most associated with death within 30 days of operation (D30). Risk groups were created using classification tree analysis based on these preoperative variables. The resulting risk groups were validated using 2015 data, and applied to neonates and higher risk CPT codes to determine validity in high-risk subpopulations. A five-level risk classification was found to be most accurate. The preoperative need for ventilation, oxygen support, inotropic support, sepsis, the need for emergent surgery and a do not resuscitate order defined non-overlapping groups with observed rates of D30 that vary from 0.075% (Very Low Risk) to 38.6% (Very High Risk). When CPT codes where death was never observed are eliminated or when the system is applied to neonates, the groupings remained predictive of death in an ordinal manner. PMID:29351327

  9. En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?

    International Nuclear Information System (INIS)

    Lifrange, E.; Colin, C.; Dondelinger, R.F.; Fridman, V.

    2001-01-01

    This study was prospectively conducted to evaluate the clinical potential of the advanced breast biopsy instrumentation (ABBI) system as an alternative to needle localization and open surgery in the management of nonpalpable breast lesions (NPBL). One hundred and eighty-six consecutive patients were referred for management of NPBL. Thirty-six underwent an ABBI procedure, offered as a first step before possible surgery for lesions which would in any case have required complete excision. The 18 patients with a malignant ABBI biopsy underwent re-excision of the biopsy site and axillary dissection was carried out in cases of infiltrating carcinoma. The other 150 patients underwent image-guided needle biopsy. Following these procedures, 60/150 (40 %) patients underwent needle-guided surgery. Finally, 96/186 (51 %) patients required complete excision. A total of 43 benign lesions and 53 carcinomas were confirmed. Thirty-six out of 96 (38 %) excisions were obtained with the ABBI system; 17/43 (40 %) benign lesions and 11/53 (21 %) carcinomas were completely removed with the ABBI system. Out of 9 malignant specimens with a pathological size less than 10 mm, 5/9 (55 %) had tumor-free margins and in 8/9 (89 %) no residual disease was found at re-excision. The preliminary results of this study suggest that, in selected cases, en bloc excision using the ABBI procedure could be an alternative to conventional surgery. (orig.)

  10. [Vitreoretinal outpatient surgery: clinical and financial considerations].

    Science.gov (United States)

    Creuzot-Garcher, C; Aubé, H; Candé, F; Dupont, G; Guillaubey, A; Malvitte, L; Arnavielle, S; Bron, A

    2008-11-01

    Vitreoretinal surgery has benefited from great advances opening the opportunity for outpatient management. We report on the 6-month experience of outpatient surgery for vitreoretinal diseases. From November 2007 to April 2008, 270 patients benefited from a vitreoretinal surgery, with 173 retinal detachments, 63 epiretinal membranes, and 34 other procedures. Only 8.5% (n=23) of the patients had to stay at the hospital one or two nights. The main reasons were the distance from the hospital and surgery on a single-eye patient. The questionnaire given after the surgery showed that almost all the patients were satisfied with the outpatient setting. In contrast, the financial results showed a loss of income of around 400,000 euros due to the low level of payment of outpatient surgery in France by the national health insurance system. Vitreoretinal surgery can be achieved in outpatient surgery with an improvement in the information given to the patients and the overall organization of the hospitalization. However, the current income provided with vitreoretinal outpatient surgery is highly disadvantageous in France, preventing this method from being generalized.

  11. Legal and ethical issues in robotic surgery.

    Science.gov (United States)

    Mavroforou, A; Michalodimitrakis, E; Hatzitheo-Filou, C; Giannoukas, A

    2010-02-01

    With the rapid introduction of revolutionary technologies in surgical practice, such as computer-enhanced robotic surgery, the complexity in various aspects, including medical, legal and ethical, will increase exponentially. Our aim was to highlight important legal and ethical implications emerged from the application of robotic surgery. Search of the pertinent medical and legal literature. Robotic surgery may open new avenues in the near future in surgical practice. However, in robotic surgery, special training and experience along with high quality assessment are required in order to provide normal conscientious care and state-of-the-art treatment. While the legal basis for professional liability remains exactly the same, litigation with the use of robotic surgery may be complex. In case of an undesirable outcome, in addition to physician and hospital, the manufacturer of the robotic system may be sued. In respect to ethical issues in robotic surgery, equipment safety and reliability, provision of adequate information, and maintenance of confidentiality are all of paramount importance. Also, the cost of robotic surgery and the lack of such systems in most of the public hospitals may restrict the majority from the benefits offered by the new technology. While surgical robotics will have a significant impact on surgical practice, it presents challenges so much in the realm of law and ethics as of medicine and health care.

  12. Patients' perceptions of waiting for bariatric surgery: a qualitative study.

    Science.gov (United States)

    Gregory, Deborah M; Temple Newhook, Julia; Twells, Laurie K

    2013-10-18

    In Canada waiting lists for bariatric surgery are common, with wait times on average > 5 years. The meaning of waiting for bariatric surgery from the patients' perspective must be understood if health care providers are to act as facilitators in promoting satisfaction with care and quality care outcomes. The aims of this study were to explore patients' perceptions of waiting for bariatric surgery, the meaning and experience of waiting, the psychosocial and behavioral impact of waiting for treatment and identify health care provider and health system supportive measures that could potentially improve the waiting experience. Twenty-one women and six men engaged in in-depth interviews that were digitally recorded, transcribed verbatim and analysed using a grounded theory approach to data collection and analysis between June 2011 and April 2012. The data were subjected to re-analysis to identify perceived health care provider and health system barriers to accessing bariatric surgery. Thematic analysis identified inequity as a barrier to accessing bariatric surgery. Three areas of perceived inequity were identified from participants' accounts: socioeconomic inequity, regional inequity, and inequity related to waitlist prioritization. Although excited about their acceptance as candidates for surgery, the waiting period was described as stressful, anxiety provoking, and frustrating. Anger was expressed towards the health care system for the long waiting times. Participants identified the importance of health care provider and health system supports during the waiting period. Recommendations on how to improve the waiting experience included periodic updates from the surgeon's office about their position on the wait list; a counselor who specializes in helping people going through this surgery, dietitian support and further information on what to expect after surgery, among others. Patients' perceptions of accessing and waiting for bariatric surgery are shaped by perceived

  13. Neuronavigation in brain tumor surgery:clinical beta-phase of the Oulu Neuronavigator System

    OpenAIRE

    Schiffbauer, H. (Hagen)

    1999-01-01

    Abstract Interactive image-guided neurosurgery for the resection of brain tumors was developed within the last 10 years at different neurosurgical centers around the world to improve the safety of the surgery and the functional outcome of the patients. Since 1987, the Oulu Neuronavigator System, consisting mainly of a mechanical arm, visualization software, an ultrasound transducer and a computer, was developed at the Neurosurgical Research Unit, University of Oulu, Finland. It was the fir...

  14. Robotics in reproductive surgery: strengths and limitations.

    Science.gov (United States)

    Catenacci, M; Flyckt, R L; Falcone, T

    2011-09-01

    Minimally invasive surgical techniques are becoming increasingly common in gynecologic surgery. However, traditional laparoscopy can be challenging. A robotic surgical system gives several advantages over traditional laparoscopy and has been incorporated into reproductive gynecological surgeries. The objective of this article is to review recent publications on robotically-assisted laparoscopy for reproductive surgery. Recent clinical research supports robotic surgery as resulting in less post-operative pain, shorter hospital stays, faster return to normal activities, and decreased blood loss. Reproductive outcomes appear similar to alternative approaches. Drawbacks of robotic surgery include longer operating room times, the need for specialized training, and increased cost. Larger prospective studies comparing robotic approaches with laparoscopy and conventional open surgery have been initiated and information regarding long-term outcomes after robotic surgery will be important in determining the ultimate utility of these procedures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Error analysis for determination of accuracy of an ultrasound navigation system for head and neck surgery.

    Science.gov (United States)

    Kozak, J; Krysztoforski, K; Kroll, T; Helbig, S; Helbig, M

    2009-01-01

    The use of conventional CT- or MRI-based navigation systems for head and neck surgery is unsatisfactory due to tissue shift. Moreover, changes occurring during surgical procedures cannot be visualized. To overcome these drawbacks, we developed a novel ultrasound-guided navigation system for head and neck surgery. A comprehensive error analysis was undertaken to determine the accuracy of this new system. The evaluation of the system accuracy was essentially based on the method of error definition for well-established fiducial marker registration methods (point-pair matching) as used in, for example, CT- or MRI-based navigation. This method was modified in accordance with the specific requirements of ultrasound-guided navigation. The Fiducial Localization Error (FLE), Fiducial Registration Error (FRE) and Target Registration Error (TRE) were determined. In our navigation system, the real error (the TRE actually measured) did not exceed a volume of 1.58 mm(3) with a probability of 0.9. A mean value of 0.8 mm (standard deviation: 0.25 mm) was found for the FRE. The quality of the coordinate tracking system (Polaris localizer) could be defined with an FLE of 0.4 +/- 0.11 mm (mean +/- standard deviation). The quality of the coordinates of the crosshairs of the phantom was determined with a deviation of 0.5 mm (standard deviation: 0.07 mm). The results demonstrate that our newly developed ultrasound-guided navigation system shows only very small system deviations and therefore provides very accurate data for practical applications.

  16. Landmark-based augmented reality system for paranasal and transnasal endoscopic surgeries.

    Science.gov (United States)

    Thoranaghatte, Ramesh; Garcia, Jaime; Caversaccio, Marco; Widmer, Daniel; Gonzalez Ballester, Miguel A; Nolte, Lutz-P; Zheng, Guoyan

    2009-12-01

    In this paper we present a landmark-based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope. Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set-up. Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set-up (metallic grid) and was 2.25 mm during cadaver studies. A novel landmark-based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future. Copyright (c) 2009 John Wiley & Sons, Ltd.

  17. THE N.I. PIROGOV'S CONTRIBUTION TO THE SURGERY OF MUSCULOSKELETAL SYSTEM (ON THE OCCASION OF THE 200-th ANNIVERSARY OF THE BIRTH

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2010-01-01

    Full Text Available Based on the analysis of the scientific heritage the authors presented the contribution of the great Russian surgeon N.I. Pirogov in the development of surgery of the locomotor system. Discussed in detail next lines of activity of N.I. Pirogov being of interest of trauma and orthopedic surgeons, in particular the: anatomical and physiological approach to studying the issues of surgery of extremities, development of scientific and organizational bases in the domestic military-field surgery, the Pirogov's ideas in the field of reconstructive surgery of the extremities, as well as its contribution to the reforming of surgical education in Russia and improvement of the domestic surgical instruments.

  18. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    Minimal latency is important for augmented reality systems and teleoperation interfaces as even small increases in latency can affect user performance. Previously, we have developed an augmented reality system that can overlay stereoscopic video streams with computer graphics in order to improve....... The latency of the da Vinci S surgical system was on average 62 ms. None of the components of our overlay system (separately or combined) significantly affected the latency. However, the latency of the assistant's monitor increased by 14 ms. Passing the video streams through CPU or GPU memory increased...... visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...

  19. The lacrimal system: diagnosis, management, and surgery

    National Research Council Canada - National Science Library

    Cohen, Adam J; Mercandetti, Michael; Brazzo, Brian G

    2006-01-01

    ... and techniques presented represent the state of the art of lacrimal diagnosis and surgery. There is mention of lacrimal infection dating back to the Code of Hammurabi in 2250 BC, but it was not until the late 1800s that real progress began to be made. Toti, an ENT surgeon in Florence, Italy, described external dacryocystorhinostomy (DCR) with turb...

  20. Gender and socioeconomic status as determinants of waiting time for inpatient surgery in a system with implicit queue management.

    Science.gov (United States)

    Arnesen, Kjell E; Erikssen, Jan; Stavem, Knut

    2002-12-01

    In a system with implicit queue management, to examine gender and socioeconomic status as determinants of waiting time for inpatient surgery, after adjusting for other potential predictors. A cohort of 452 subjects was examined in outpatient clinics of a general hospital and referred to inpatient surgery. They were followed until scheduled hospital admission (n=396) or until the requested procedure no longer was relevant (n=56). We compared waiting time between groups from referral date until hospital admission, using Kaplan-Meier estimates of waiting times and log rank test. A Cox proportional hazards model was used for assessing the risk ratio (RR) of hospital admission for scheduled surgery. Gender and socioeconomic status could not explain variations in waiting time. However, patients with suspected/verified neoplastic disease or a risk of serious deterioration without treatment had markedly shorter waiting times than the reference groups, with adjusted RR (95% confidence intervals (95%CI)) of time to receiving in-patient surgery of 2.3 (1.7-3.0) and 2.0 (1.3-3.0), respectively. Being on sick leave was associated with shorter waiting time, adjusted RR of 1.7 (1.2-2.5). Referrals from within the hospital or other hospitals had also shorter waiting times than referrals from primary health care physicians, adjusted RR=1.4 (1.1-1.8). There was no evidence of bias against women or people in lower socioeconomic classes in this implicit queue management system. However, patients' access to inpatient surgery was associated with malignancy, prognosis, sick leave status, physician experience, referral pattern and the major diagnosis category.

  1. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  2. Cardiovascular and respiratory changes and convalescence in laparoscopic colonic surgery

    DEFF Research Database (Denmark)

    Schulze, S; Lyng, K M; Bugge, K

    1999-01-01

    Gasless laparoscopy produces smaller cardiopulmonary and systemic changes than carbon dioxide (CO2) laparoscopy during colonic surgery.......Gasless laparoscopy produces smaller cardiopulmonary and systemic changes than carbon dioxide (CO2) laparoscopy during colonic surgery....

  3. ROBOTIC SURGERY FOR GIANT PRESACRAL DUMBBELL-SHAPE SCHWANNOMA

    Directory of Open Access Journals (Sweden)

    Farid Yudoyono

    2015-03-01

    Full Text Available Objective: To demonstrate the feasibility of using da Vinci robotic surgical system to perform spinal surgery. Methods: Magnetic resonance imaging (MRI of a 29-year-old female patient complaining right pelvic pain for 1 month revealed a 17x8x10 cm non-homogeneous dumbbell shape encapsulated mass with cystic change located in the pelvic cavity and caused an anterior displacement of urinary bladder and colon. Results: There was no systemic complication and pain decrease 24 hours after surgery and during 2 years of follow up. The patient started a diet 6 hours after the surgery and was discharged 72 hours after the surgery. The pathological diagnosis of the tumor was schwannoma. Conclusions: Giant dumbbell shape presacral schwannomas are rare tumours and their surgical treatment is challenging because of the complex anatomy of the presacral. Clinical application of da Vinci robotic surgical system in the spinal surgical field is currently confined to the treatment of some specific diseases or procedures. However, robotic surgery is expected to play a practical future role as it is minimally invasive. The advent of robotic technology will prove to be a boon to the neurosurgeon.

  4. New technologies in robotic surgery: the Korean experience.

    Science.gov (United States)

    Tuliao, Patrick H; Kim, Sang W; Rha, Koon H

    2014-01-01

    The development of the robotic systems has made surgery an increasingly technology-driven field. Since the introduction of the first robotic platform in 2005, surgical practice in South Korea has also been caught up in the global robotic revolution. Consequently, a market focused on improving the robotic systems was created and Korea has emerged as one of its frontrunners. This article reviews the Korean experience in developing various robotic technologies and then Korea's most recent contributions to the development of new technologies in robotic surgery. The goal of new technologies in the field of robotic surgery has been to improve on the current platforms by eliminating their disadvantages. The pressing goal is to develop a platform that is less bulky, more ergonomic, and capable of providing force feedback to the surgeon. In Korea, the Lapabot and two new robotic systems for single-port laparoscopic surgery are the most recent advances that have been reported. Robotic surgery is rapidly evolving and Korea has stayed in the forefront of its development. These new advancements in technology will eventually produce better robotic platforms that will greatly improve the manner in which surgical care is delivered.

  5. An Innovative Streaming Video System With a Point-of-View Head Camera Transmission of Surgeries to Smartphones and Tablets: An Educational Utility.

    Science.gov (United States)

    Chaves, Rafael Oliveira; de Oliveira, Pedro Armando Valente; Rocha, Luciano Chaves; David, Joacy Pedro Franco; Ferreira, Sanmari Costa; Santos, Alex de Assis Santos Dos; Melo, Rômulo Müller Dos Santos; Yasojima, Edson Yuzur; Brito, Marcus Vinicius Henriques

    2017-10-01

    In order to engage medical students and residents from public health centers to utilize the telemedicine features of surgery on their own smartphones and tablets as an educational tool, an innovative streaming system was developed with the purpose of streaming live footage from open surgeries to smartphones and tablets, allowing the visualization of the surgical field from the surgeon's perspective. The current study aims to describe the results of an evaluation on level 1 of Kirkpatrick's Model for Evaluation of the streaming system usage during gynecological surgeries, based on the perception of medical students and gynecology residents. Consisted of a live video streaming (from the surgeon's point of view) of gynecological surgeries for smartphones and tablets, one for each volunteer. The volunteers were able to connect to the local wireless network, created by the streaming system, through an access password and watch the video transmission on a web browser on their smartphones. Then, they answered a Likert-type questionnaire containing 14 items about the educational applicability of the streaming system, as well as comparing it to watching an in loco procedure. This study is formally approved by the local ethics commission (Certificate No. 53175915.7.0000.5171/2016). Twenty-one volunteers participated, totalizing 294 items answered, in which 94.2% were in agreement with the items affirmative, 4.1% were neutral, and only 1.7% answers corresponded to negative impressions. Cronbach's α was .82, which represents a good reliability level. Spearman's coefficients were highly significant in 4 comparisons and moderately significant in the other 20 comparisons. This study presents a local streaming video system of live surgeries to smartphones and tablets and shows its educational utility, low cost, and simple usage, which offers convenience and satisfactory image resolution, thus being potentially applicable in surgical teaching.

  6. The effect of three different doses of tranexamic acid on blood loss after cardiac surgery with mild systemic hypothermia (32 degrees C).

    Science.gov (United States)

    Karski, J M; Dowd, N P; Joiner, R; Carroll, J; Peniston, C; Bailey, K; Glynn, M F; Teasdale, S J; Cheng, D C

    1998-12-01

    Prophylactic administration of tranexamic acid (TA), an antifibrinolytic agent, decreases bleeding after cardiac surgery with systemic hypothermia (25 degrees C to 29 degrees C). Warmer systemic temperatures during cardiopulmonary bypass (CPB) may reduce bleeding and thus alter the requirement for TA. The effect of three different doses of TA on bleeding after cardiac surgery with mild systemic hypothermia (32 degrees C) is evaluated. Double-blind, prospective, randomized study. University hospital. One hundred fifty adult patients undergoing aortocoronary bypass or valvular cardiac surgery. Patients received TA, 50 (n = 50), 100 (n = 50), or 150 (n = 50) mg/kg intravenously before CPB with mild systemic hypothermia. Blood loss through chest drains over 6, 12, and 24 hours after surgery and total hemoglobin loss were measured. Autotransfused blood, transfused banked blood and blood products, and coagulation profiles were measured. Analysis of variance on log-transformed data for blood loss and confidence intervals (CIs) of 0.95 were calculated and transformed to milliliters of blood. No patient was re-explored for bleeding. Blood loss at 6 hours was statistically greater in the 50-mg/kg group compared with the other two groups (p = 0.03; p = 0.02). Total hemoglobin loss was statistically greater in the 50-mg/kg group compared with the 150-mg/kg group (p = 0.04). There was no statistical difference in blood tranfusion rate or coagulation profiles among the three groups. However, preoperative hemoglobin level was statistically lower in the 150-mg/kg group compared with the other two groups (p = 0.01). Of the three doses of TA studied, the most efficacious and cost-effective dose to reduce bleeding after cardiac surgery with mild hypothermic systemic perfusion is 100 mg/kg.

  7. Robotic cardiac surgery: an anaesthetic challenge.

    Science.gov (United States)

    Wang, Gang; Gao, Changqing

    2014-08-01

    Robotic cardiac surgery with the da Vinci robotic surgical system offers the benefits of a minimally invasive procedure, including a smaller incision and scar, reduced risk of infection, less pain and trauma, less bleeding and blood transfusion requirements, shorter hospital stay and decreased recovery time. Robotic cardiac surgery includes extracardiac and intracardiac procedures. Extracardiac procedures are often performed on a beating heart. Intracardiac procedures require the aid of peripheral cardiopulmonary bypass via a minithoracotomy. Robotic cardiac surgery, however, poses challenges to the anaesthetist, as the obligatory one-lung ventilation (OLV) and CO2 insufflation may reduce cardiac output and increase pulmonary vascular resistance, potentially resulting in hypoxaemia and haemodynamic compromise. In addition, surgery requires appropriate positioning of specialised cannulae such as an endopulmonary vent, endocoronary sinus catheter, and endoaortic clamp catheter under the guidance of transoesophageal echocardiography. Therefore, cardiac anaesthetists should have a working knowledge of these systems, OLV and haemodynamic support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Intra-abdominal recurrence of colorectal cancer detected by radioimmunoguided surgery (RIGS system)

    International Nuclear Information System (INIS)

    Sardi, A.; Workman, M.; Mojzisik, C.; Hinkle, G.; Nieroda, C.; Martin, E.W. Jr.

    1989-01-01

    Since 1986, 32 patients with metastatic colorectal cancer have undergone second-look radioimmunoguided surgery (RIGS system). The primary tumor was located in the right and transverse colon in 11 patients, left and sigmoid colon in 16, and rectum in five. The carcinoembryonic antigen level was elevated in 30 patients (94%); all patients underwent a computed tomographic scan of the abdomen and pelvis. The overall sensitivity of the computed tomographic scan was 41% (abdomen other than liver, 27%; liver, 58%; and pelvis, 22%). The RIGS system identified recurrent tumor in 81% of the patients. The most common site of metastasis was the liver (41%), independent of the primary location. Local/regional recurrences alone accounted for 40% of all recurrences. In six patients (18%), recurrent tumor was found only with the RIGS system. The RIGS system is more dependable in localizing clinically obscure metastases than other methods, and carcinoembryonic antigen testing remains the most accurate preoperative method to indicate suspected recurrences

  9. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  10. Cost-Effectiveness of Surgery, Stereotactic Body Radiation Therapy, and Systemic Therapy for Pulmonary Oligometastases

    Energy Technology Data Exchange (ETDEWEB)

    Lester-Coll, Nataniel H., E-mail: nataniel.lester-coll@yale.edu [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Rutter, Charles E.; Bledsoe, Trevor J. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Goldberg, Sarah B. [Department of Medicine (Medical Oncology), Yale University School of Medicine, New Haven, Connecticut (United States); Decker, Roy H.; Yu, James B. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States)

    2016-06-01

    Introduction: Pulmonary oligometastases have conventionally been managed with surgery and/or systemic therapy. However, given concerns about the high cost of systemic therapy and improvements in local treatment of metastatic cancer, the optimal cost-effective management of these patients is unclear. Therefore, we sought to assess the cost-effectiveness of initial management strategies for pulmonary oligometastases. Methods and Materials: A cost-effectiveness analysis using a Markov modeling approach was used to compare average cumulative costs, quality adjusted life years (QALYs), and incremental cost-effectiveness ratios (ICERs) among 3 initial disease management strategies: video-assisted thoracic surgery (VATS) wedge resection, stereotactic body radiation therapy (SBRT), and systemic therapy among 5 different cohorts of patient disease: (1) melanoma; (2) non-small cell lung cancer adenocarcinoma without an EGFR mutation (NSCLC AC); (3) NSCLC with an EGFR mutation (NSCLC EGFRm AC); (4) NSCLC squamous cell carcinoma (NSCLC SCC); and (5) colon cancer. One-way sensitivity analyses and probabilistic sensitivity analyses were performed to analyze uncertainty with regard to model parameters. Results: In the base case, SBRT was cost effective for melanoma, with costs/net QALYs of $467,787/0.85. In patients with NSCLC, the most cost-effective strategies were SBRT for AC ($156,725/0.80), paclitaxel/carboplatin for SCC ($123,799/0.48), and erlotinib for EGFRm AC ($147,091/1.90). Stereotactic body radiation therapy was marginally cost-effective for EGFRm AC compared to erlotinib with an incremental cost-effectiveness ratio of $126,303/QALY. For colon cancer, VATS wedge resection ($147,730/2.14) was the most cost-effective strategy. Variables with the greatest influence in the model were erlotinib-associated progression-free survival (EGFRm AC), toxicity (EGFRm AC), cost of SBRT (NSCLC SCC), and patient utilities (all histologies). Conclusions: Video-assisted thoracic

  11. New trends in minimally invasive urological surgery

    Directory of Open Access Journals (Sweden)

    Prabhakar Rajan

    2009-10-01

    Full Text Available Purpose: The perceived benefits of minimally-invasive surgery include less postoperative pain, shorter hospitalization, reduced morbidity and better cosmesis while maintaining diagnostic accuracy and therapeutic outcome. We review the new trends in minimally-invasive urological surgery. Materials and method: We reviewed the English language literature using the National Library of Medicine database to identify the latest technological advances in minimally-invasive surgery with particular reference to urology. Results: Amongst other advances, studies incorporating needlescopic surgery, laparoendoscopic single-site surgery , magnetic anchoring and guidance systems, natural orifice transluminal endoscopic surgery and flexible robots were considered of interest. The results from initial animal and human studies are also outlined. Conclusion: Minimally-invasive surgery continues to evolve to meet the demands of the operators and patients. Many novel technologies are still in the testing phase, whilst others have entered clinical practice. Further evaluation is required to confirm the safety and efficacy of these techniques and validate the published reports.

  12. KinoHaptics: An Automated, Wearable, Haptic Assisted, Physio-therapeutic System for Post-surgery Rehabilitation and Self-care.

    Science.gov (United States)

    Rajanna, Vijay; Vo, Patrick; Barth, Jerry; Mjelde, Matthew; Grey, Trevor; Oduola, Cassandra; Hammond, Tracy

    2016-03-01

    A carefully planned, structured, and supervised physiotherapy program, following a surgery, is crucial for the successful diagnosis of physical injuries. Nearly 50 % of the surgeries fail due to unsupervised, and erroneous physiotherapy. The demand for a physiotherapist for an extended period is expensive to afford, and sometimes inaccessible. Researchers have tried to leverage the advancements in wearable sensors and motion tracking by building affordable, automated, physio-therapeutic systems that direct a physiotherapy session by providing audio-visual feedback on patient's performance. There are many aspects of automated physiotherapy program which are yet to be addressed by the existing systems: a wide classification of patients' physiological conditions to be diagnosed, multiple demographics of the patients (blind, deaf, etc.), and the need to pursue patients to adopt the system for an extended period for self-care. In our research, we have tried to address these aspects by building a health behavior change support system called KinoHaptics, for post-surgery rehabilitation. KinoHaptics is an automated, wearable, haptic assisted, physio-therapeutic system that can be used by a wide variety of demographics and for various physiological conditions of the patients. The system provides rich and accurate vibro-haptic feedback that can be felt by the user, irrespective of the physiological limitations. KinoHaptics is built to ensure that no injuries are induced during the rehabilitation period. The persuasive nature of the system allows for personal goal-setting, progress tracking, and most importantly life-style compatibility. The system was evaluated under laboratory conditions, involving 14 users. Results show that KinoHaptics is highly convenient to use, and the vibro-haptic feedback is intuitive, accurate, and has shown to prevent accidental injuries. Also, results show that KinoHaptics is persuasive in nature as it supports behavior change and habit building

  13. Precision in robotic rectal surgery using the da Vinci Xi system and integrated table motion, a technical note.

    Science.gov (United States)

    Panteleimonitis, Sofoklis; Harper, Mick; Hall, Stuart; Figueiredo, Nuno; Qureshi, Tahseen; Parvaiz, Amjad

    2017-09-15

    Robotic rectal surgery is becoming increasingly more popular among colorectal surgeons. However, time spent on robotic platform docking, arm clashing and undocking of the platform during the procedure are factors that surgeons often find cumbersome and time consuming. The newest surgical platform, the da Vinci Xi, coupled with integrated table motion can help to overcome these problems. This technical note aims to describe a standardised operative technique of single docking robotic rectal surgery using the da Vinci Xi system and integrated table motion. A stepwise approach of the da Vinci docking process and surgical technique is described accompanied by an intra-operative video that demonstrates this technique. We also present data collected from a prospectively maintained database. 33 consecutive rectal cancer patients (24 male, 9 female) received robotic rectal surgery with the da Vinci Xi during the preparation of this technical note. 29 (88%) patients had anterior resections, and four (12%) had abdominoperineal excisions. There were no conversions, no anastomotic leaks and no mortality. Median operation time was 331 (249-372) min, blood loss 20 (20-45) mls and length of stay 6.5 (4-8) days. 30-day readmission rate and re-operation rates were 3% (n = 1). This standardised technique of single docking robotic rectal surgery with the da Vinci Xi is safe, feasible and reproducible. The technological advances of the new robotic system facilitate the totally robotic single docking approach.

  14. [Laparoscopic colorectal surgery - SILS, robots, and NOTES.

    NARCIS (Netherlands)

    D'Hoore, André; Wolthuis, Albert M.; Mizrahi, Hagar; Parker, Mike; Bemelman, Willem A.; Wara, Pål

    2011-01-01

    Single incision laparoscopic surgery resection of colon is feasible, but so far evidence of benefit compared to standard laparoscopic technique is lacking. In addition to robot-controlled camera, there is only one robot system on the market capable of performing laparoscopic surgery. The da Vinci

  15. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery.

    Science.gov (United States)

    Shinkawa, Takeshi; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2017-05-01

    A ferromagnetic surgical system (FMwand®) is a new type of dissection device expected to reduce the risk of adjacent tissue damage. We reviewed 426 congenital cardiac operations with cardiopulmonary bypass through redo sternotomy to assess if this device prevented phrenic nerve injury. The ferromagnetic surgical system was used in 203 operations (47.7%) with regular electrocautery and scissors. The preoperative and operative details were similar between the operations with or without the ferromagnetic surgical system. The incidence of phrenic nerve injury was significantly lower with the ferromagnetic surgical system (0% vs 2.7%, P = 0.031). A logistic regression model showed that the use of the ferromagnetic surgical system was significantly associated with reduced odds of phrenic nerve injury (P < 0.001). © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. A novel smart navigation system for intramedullary nailing in orthopedic surgery.

    Directory of Open Access Journals (Sweden)

    Jaesuk Choi

    Full Text Available This paper proposes a novel smart surgical navigation system for intramedullary nailing in orthopedic surgery. Using a handle-integrated laser guidance module, the system can target a drill insertion point onto skin, indicating an accurate target position to perpendicularly access an invisible distal hole. The proposed handle-integration-based fixation of the laser guidance module precisely defines the relative position of the module with respect to the distal hole. Consequently, unlike conventional systems, the proposed system can indicate the target insertion point without any help from bulky and costly external position-tracking equipment that is usually required for compensating disturbances generated by external impacts. After insertion, a correct drilling direction toward the distal hole is guided by real-time drilling angle measurement modules-one integrated with the nail handle and the other with the drill body. Each module contains a 9-axis inertial sensor and a Bluetooth communication device. These two modules work together to provide real-time drilling angle data, allowing calculation of the directional error toward the center of the distal hole in real time. The proposed system removes the need for fluoroscopy and provides a compact and cost-effective solution compared with conventional systems.

  17. [History of cranial surgery, cerebral tumor surgery and epilepsy surgery in Mexico].

    Science.gov (United States)

    Chico-Ponce de León, F

    2009-08-01

    The first report of intra-cerebral tumor surgery was provided by Bennett & Goodle, in London, 1884. Worldwide this kind of surgery was performed in France by Chipault, in Italy by Durante, in the United States by Keen and in Deutchland by Krause & Oppenheim. Lavista in Mexico City operated on intra-cerebral tumor in 1891, and the report was printed in 1892. In the same publication, Lavista exhibited the first cases of epilepsy surgery. Since now, it is the first report of this kind of surgery in the Spanish-speaking world.

  18. Complications After Cosmetic Surgery Tourism.

    Science.gov (United States)

    Klein, Holger J; Simic, Dario; Fuchs, Nina; Schweizer, Riccardo; Mehra, Tarun; Giovanoli, Pietro; Plock, Jan A

    2017-04-01

    Cosmetic surgery tourism characterizes a phenomenon of people traveling abroad for aesthetic surgery treatment. Problems arise when patients return with complications or need of follow-up care. To investigate the complications of cosmetic surgery tourism treated at our hospital as well as to analyze arising costs for the health system. Between 2010 and 2014, we retrospectively included all patients presenting with complications arising from cosmetic surgery abroad. We reviewed medical records for patients' characteristics including performed operations, complications, and treatment. Associated cost expenditure and Diagnose Related Groups (DRG)-related reimbursement were analyzed. In total 109 patients were identified. All patients were female with a mean age of 38.5 ± 11.3 years. Most procedures were performed in South America (43%) and Southeast (29.4%) or central Europe (24.8%), respectively. Favored procedures were breast augmentation (39.4%), abdominoplasty (11%), and breast reduction (7.3%). Median time between the initial procedure abroad and presentation was 15 days (interquartile range [IQR], 9) for early, 81.5 days (IQR, 69.5) for midterm, and 4.9 years (IQR, 9.4) for late complications. Main complications were infections (25.7%), wound breakdown (19.3%), and pain/discomfort (14.7%). The majority of patients (63.3%) were treated conservatively; 34.8% became inpatients with a mean hospital stay of 5.2 ± 3.8 days. Overall DRG-related reimbursement premiums approximately covered the total costs. Despite warnings regarding associated risks, cosmetic surgery tourism has become increasingly popular. Efficient patients' referral to secondary/tertiary care centers with standardized evaluation and treatment can limit arising costs without imposing a too large burden on the social healthcare system. 4. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  19. Robotics in general surgery: an evidence-based review.

    Science.gov (United States)

    Baek, Se-Jin; Kim, Seon-Hahn

    2014-05-01

    Since its introduction, robotic surgery has been rapidly adopted to the extent that it has already assumed an important position in the field of general surgery. This rapid progress is quantitative as well as qualitative. In this review, we focus on the relatively common procedures to which robotic surgery has been applied in several fields of general surgery, including gastric, colorectal, hepato-biliary-pancreatic, and endocrine surgery, and we discuss the results to date and future possibilities. In addition, the advantages and limitations of the current robotic system are reviewed, and the advanced technologies and instruments to be applied in the near future are introduced. Such progress is expected to facilitate the widespread introduction of robotic surgery in additional fields and to solve existing problems.

  20. Future of robotic surgery in urology.

    Science.gov (United States)

    Rassweiler, Jens J; Autorino, Riccardo; Klein, Jan; Mottrie, Alex; Goezen, Ali Serdar; Stolzenburg, Jens-Uwe; Rha, Koon H; Schurr, Marc; Kaouk, Jihad; Patel, Vipul; Dasgupta, Prokar; Liatsikos, Evangelos

    2017-12-01

    To provide a comprehensive overview of the current status of the field of robotic systems for urological surgery and discuss future perspectives. A non-systematic literature review was performed using PubMed/Medline search electronic engines. Existing patents for robotic devices were researched using the Google search engine. Findings were also critically analysed taking into account the personal experience of the authors. The relevant patents for the first generation of the da Vinci platform will expire in 2019. New robotic systems are coming onto the stage. These can be classified according to type of console, arrangement of robotic arms, handles and instruments, and other specific features (haptic feedback, eye-tracking). The Telelap ALF-X robot uses an open console with eye-tracking, laparoscopy-like handles with haptic feedback, and arms mounted on separate carts; first clinical trials with this system were reported in 2016. The Medtronic robot provides an open console using three-dimensional high-definition video technology and three arms. The Avatera robot features a closed console with microscope-like oculars, four arms arranged on one cart, and 5-mm instruments with six degrees of freedom. The REVO-I consists of an open console and a four-arm arrangement on one cart; the first experiments with this system were published in 2016. Medicaroid uses a semi-open console and three robot arms attached to the operating table. Clinical trials of the SP 1098-platform using the da Vinci Xi for console-based single-port surgery were reported in 2015. The SPORT robot has been tested in animal experiments for single-port surgery. The SurgiBot represents a bedside solution for single-port surgery providing flexible tube-guided instruments. The Avicenna Roboflex has been developed for robotic flexible ureteroscopy, with promising early clinical results. Several console-based robots for laparoscopic multi- and single-port surgery are expected to come to market within the

  1. [Immunological status of the pediatric patient who has undergone heart surgery].

    Science.gov (United States)

    Valenzuela Flores, A; Wakida, G; Limón Rojas, A; Obregón, C; Orihuela, O; Romero, C

    1995-01-01

    Communication of results a study the effect of open and closed-heart surgery in the immune system of infants and children. Data collected 24 hrs before anesthesia and surgery and five days after surgery. Operating room and pediatric intensive care of Hospital Central de Petróleos Mexicanos (PEMEX) in the South, Mexico City. Children undergoing surgery for correction of congenital heart disease (age 16 months to 14 years). A total of 16 patients. increased neutrophil counts with luymphopenia in both groups (p < 0.05), serum levels of the complement components C3 and C4 were higher after surgery, serum immunoglobulin IgG, IgA and IgM were higher after surgery, serum immunoglobulin IgG, IgA and IgM were decreased form preoperative levels (p < 0.01). Two patients had infection in the surgical wound. The effect of open and closed-heart surgery produced transitory immunodeficiency with recuperation of his immune systems and 5th day after surgery.

  2. Bariatric surgery insurance requirements independently predict surgery dropout.

    Science.gov (United States)

    Love, Kaitlin M; Mehaffey, J Hunter; Safavian, Dana; Schirmer, Bruce; Malin, Steven K; Hallowell, Peter T; Kirby, Jennifer L

    2017-05-01

    Many insurance companies have considerable prebariatric surgery requirements despite a lack of evidence for improved clinical outcomes. The hypothesis of this study is that insurance-specific requirements will be associated with a decreased progression to surgery and increased delay in time to surgery. Retrospective data collection was performed for patients undergoing bariatric surgery evaluation from 2010-2015. Patients who underwent surgery (SGY; n = 827; mean body mass index [BMI] 49.1) were compared with those who did not (no-SGY; n = 648; mean BMI: 49.4). Univariate and multivariate analysis were performed to identify specific co-morbidity and insurance specific predictors of surgical dropout and time to surgery. A total of 1475 patients using 12 major insurance payors were included. Univariate analysis found insurance requirements associated with surgical drop out included longer median diet duration (no-SGY = 6 mo; SGY = 3 mo; Psurgery dropout. Additionally, surgical patients had an average interval between initial visit and surgery of 5.8±4.6 months with significant weight gain (2.1 kg, Psurgery insurance requirements were associated with lack of patient progression to surgery in this study. In addition, delays in surgery were associated with preoperative weight gain. Although prospective and multicenter studies are needed, these findings have major policy implications suggesting insurance requirements may need to be reconsidered to improve medical care. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  3. Cost-Benefit Performance Simulation of Robot-Assisted Thoracic Surgery As Required for Financial Viability under the 2016 Revised Reimbursement Paradigm of the Japanese National Health Insurance System.

    Science.gov (United States)

    Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-04-20

    To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.

  4. [Robotics in general surgery: personal experience, critical analysis and prospectives].

    Science.gov (United States)

    Fracastoro, Gerolamo; Borzellino, Giuseppe; Castelli, Annalisa; Fiorini, Paolo

    2005-01-01

    Today mini invasive surgery has the chance to be enhanced with sophisticated informative systems (Computer Assisted Surgery, CAS) like robotics, tele-mentoring and tele-presence. ZEUS and da Vinci, present in more than 120 Centres in the world, have been used in many fields of surgery and have been tested in some general surgical procedures. Since the end of 2003, we have performed 70 experimental procedures and 24 operations of general surgery with ZEUS robotic system, after having properly trained 3 surgeons and the operating room staff. Apart from the robot set-up, the mean operative time of the robotic operations was similar to the laparoscopic ones; no complications due to robotic technique occurred. The Authors report benefits and disadvantages related to robots' utilization, problems still to be solved and the possibility to make use of them with tele-surgery, training and virtual surgery.

  5. [Comparison between the Austrian and German DRG systems in hand surgery].

    Science.gov (United States)

    Lotter, O; Jaminet, P; Schwarzach, S; Schaller, H E

    2013-02-01

    Diagnosis-Related Groups (DRG) are a patient classification system grouping related types of patients treated to the resources they consumed. In this analysis, we compared the Austrian and the German DRG systems. The 15 most common hand surgical diagnoses and their corresponding operative treatment were transferred into the Austrian system. Thus, the length of stay and the reimbursement of both countries could be obtained and compared. The mean values and the median values of the upper and lower thresholds of length of stay as well as the average length of stay were all lower in Austria compared to Germany. Reimbursement in Germany was higher in 13 of 19 cases. Total proceeds amounted to 1.67 million in the German and 1.70 million in the Austrian health care system. Considering the purchasing power applying consumer prize parities, the difference of reimbursement between the countries rose to 130,000 which equals a difference of almost 8%. Reimbursement of the top 15 diagnoses in hand surgery in Austria is 8% higher than in Germany. Except for one case, mean values as well as upper and lower thresholds of length of stay are considerably shorter in Austria. Comparison of international data to refine a national compensation system is advocated.

  6. Robot-assisted surgery: the future is here.

    Science.gov (United States)

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  7. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for hospital outpatient departments - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of hospital outpatient department ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS)...

  8. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ...

  9. Attitudes of surgeons to the use of postoperative markers of the systemic inflammatory response following elective surgery

    Directory of Open Access Journals (Sweden)

    Ross D. Dolan

    2017-09-01

    Conclusion: Although there was a limited response the majority of surgeons surveyed measure the systemic inflammatory response following elective surgery and use CRP measurements together with clinical findings to guide postoperative care. The present results provide a baseline against which future surveys can be compared.

  10. Reproductive Endocrinology: Pregnancy and fertility after bariatric surgery.

    Science.gov (United States)

    Ginsburg, Elizabeth S

    2009-05-01

    Increases in rates of bariatric surgery are staggering, and many obese individuals who undergo such procedures are women of reproductive age. So, how does the surgery affect women's fertility and pregnancy outcomes thereafter? A new systemic review aimed to find out.

  11. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  12. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for ambulatory surgical centers - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of ambulatory surgical center ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey....

  13. Cell response to surgery.

    LENUS (Irish Health Repository)

    Ni Choileain, Niamh

    2012-02-03

    OBJECTIVES: To describe the profound alterations in host immunity that are produced by major surgery as demonstrated by experimental and clinical studies, and to evaluate the benefits of therapeutic strategies aimed at attenuating perioperative immune dysfunction. DATA SOURCES: A review of the English-language literature was conducted, incorporating searches of the MEDLINE, EMBASE, and Cochrane collaboration databases to identify laboratory and clinical studies investigating the cellular response to surgery. STUDY SELECTION: Original articles and case reports describing immune dysfunction secondary to surgical trauma were included. DATA EXTRACTION: The results were compiled to show outcomes of different studies and were compared. DATA SYNTHESIS: Current evidence indicates that the early systemic inflammatory response syndrome observed after major surgery that is characterized by proinflammatory cytokine release, microcirculatory disturbance, and cell-mediated immune dysfunction is followed by a compensatory anti-inflammatory response syndrome, which predisposes the patient to opportunistic infection, multiple organ dysfunction syndrome, and death. Because there are currently no effective treatment options for multiple organ dysfunction syndrome, measures to prevent its onset should be initiated at an early stage. Accumulating experimental evidence suggests that targeted therapeutic strategies involving immunomodulatory agents such as interferon gamma, granulocyte colony-stimulating factor, the prostaglandin E(2) antagonist, indomethacin, and pentoxifylline may be used for the treatment of systemic inflammatory response syndrome to prevent the onset of multiple organ dysfunction syndrome. CONCLUSIONS: Surgical trauma produces profound immunological dysfunction. Therapeutic strategies directed at restoring immune homeostasis should aim to redress the physiological proinflammatory-anti-inflammatory cell imbalance associated with major surgery.

  14. Augmented reality system for oral surgery using 3D auto stereoscopic visualization.

    Science.gov (United States)

    Tran, Huy Hoang; Suenaga, Hideyuki; Kuwana, Kenta; Masamune, Ken; Dohi, Takeyoshi; Nakajima, Susumu; Liao, Hongen

    2011-01-01

    We present an augmented reality system for oral and maxillofacial surgery in this paper. Instead of being displayed on a separated screen, three-dimensional (3D) virtual presentations of osseous structures and soft tissues are projected onto the patient's body, providing surgeons with exact knowledge of depth information of high risk tissues inside the bone. We employ a 3D integral imaging technique which produce motion parallax in both horizontal and vertical direction over a wide viewing area in this study. In addition, surgeons are able to check the progress of the operation in real-time through an intuitive 3D based interface which is content-rich, hardware accelerated. These features prevent surgeons from penetrating into high risk areas and thus help improve the quality of the operation. Operational tasks such as hole drilling, screw fixation were performed using our system and showed an overall positional error of less than 1 mm. Feasibility of our system was also verified with a human volunteer experiment.

  15. Medical tourism and bariatric surgery: who pays?

    Science.gov (United States)

    Sheppard, Caroline E; Lester, Erica L W; Chuck, Anderson W; Kim, David H; Karmali, Shahzeer; de Gara, Christopher J; Birch, Daniel W

    2014-12-01

    The objective of this study was to determine the short-term cost impact that medical tourism for bariatric surgery has on a public healthcare system. Due to long wait times for bariatric surgery services, Canadians are venturing to private clinics in other provinces/countries. Postoperative care in this population not only burdens the provincial health system with intervention costs required for complicated patients, but may also impact resources allotted to patients in the public clinic. A chart review was performed from January 2009 to June 2013, which identified 62 medical tourists requiring costly interventions related to bariatric surgery. Secondarily, a survey was conducted to estimate the frequency of bariatric medical tourists presenting to general surgeons in Alberta, necessary interventions, and associated costs. A threshold analysis was used to compare costs of medical tourism to those from our institution. A conservative cost estimate of $1.8 million CAD was calculated for all interventions in 62 medical tourists. The survey established that 25 Albertan general surgeons consulted 59 medical tourists per year: a cost of approximately $1 million CAD. Medical tourism was calculated to require a complication rate ≤ 28% (average intervention cost of $37,000 per patient) to equate the cost of locally conducted surgery: a rate less than the current supported evidence. Conducting 250 primary bariatric surgeries in Alberta is approximately $1.9 million less than the modeled cost of treating 250 medical tourists returning to Alberta. Medical tourism has a substantial impact on healthcare costs in Alberta. When compared to bariatric medical tourists, the complication rate for locally conducted surgery is less, and the cost of managing the complications is also much less. Therefore, we conclude that it is a better use of resources to conduct bariatric surgery for Albertan residents in Alberta than to fund patients to seek surgery out of province/country.

  16. Development of a medical robot system for minimally invasive surgery.

    Science.gov (United States)

    Feng, Mei; Fu, Yili; Pan, Bo; Liu, Chang

    2012-03-01

    Robot-assisted systems have been widely used in minimally invasive surgery (MIS) practice, and with them the precision and accuracy of surgical procedures can be significantly improved. Promoting the development of robot technology in MIS will improve robot performance and help in tackling problems from complex surgical procedures. A medical robot system with a new mechanism for MIS was proposed to achieve a two-dimensional (2D) remote centre of motion (RCM). An improved surgical instrument was designed to enhance manipulability and eliminate the coupling motion between the wrist and the grippers. The control subsystem adopted a master-slave control mode, upon which a new method with error compensation of repetitive feedback can be based for the inverse kinematics solution. A unique solution with less computation and higher satisfactory accuracy was also obtained. Tremor filtration and trajectory planning were also addressed with regard to the smoothness of the surgical instrument movement. The robot system was tested on pigs weighing 30-45 kg. The experimental results show that the robot can successfully complete a cholecystectomy and meet the demands of MIS. The results of the animal experiments were excellent, indicating a promising clinical application of the robot with high manipulability. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Designing a wearable navigation system for image-guided cancer resection surgery.

    Science.gov (United States)

    Shao, Pengfei; Ding, Houzhu; Wang, Jinkun; Liu, Peng; Ling, Qiang; Chen, Jiayu; Xu, Junbin; Zhang, Shiwu; Xu, Ronald

    2014-11-01

    A wearable surgical navigation system is developed for intraoperative imaging of surgical margin in cancer resection surgery. The system consists of an excitation light source, a monochromatic CCD camera, a host computer, and a wearable headset unit in either of the following two modes: head-mounted display (HMD) and Google glass. In the HMD mode, a CMOS camera is installed on a personal cinema system to capture the surgical scene in real-time and transmit the image to the host computer through a USB port. In the Google glass mode, a wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A software program is written in Python to call OpenCV functions for image calibration, co-registration, fusion, and display with augmented reality. The imaging performance of the surgical navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex vivo tissue model. Surgical margins identified by the wearable navigation system are co-incident with those acquired by a standard small animal imaging system, indicating the technical feasibility for intraoperative surgical margin detection. The proposed surgical navigation system combines the sensitivity and specificity of a fluorescence imaging system and the mobility of a wearable goggle. It can be potentially used by a surgeon to identify the residual tumor foci and reduce the risk of recurrent diseases without interfering with the regular resection procedure.

  18. OSAS Surgery and Postoperative Discomfort: Phase I Surgery versus Phase II Surgery

    Directory of Open Access Journals (Sweden)

    Giulio Gasparini

    2015-01-01

    Full Text Available Introduction. This study aims to investigate the reasons that discourage the patients affected by OSAS to undergo orthognathic surgery and compares the postoperative discomfort of phase I (soft tissue surgery and phase II (orthognathic surgery procedures for treatment of OSAS. Material and Methods. A pool of 46 patients affected by OSAS was divided into two groups: “surgery patients” who accepted surgical treatments of their condition and “no surgery patients” who refused surgical procedures. The “surgery patients” group was further subdivided into two arms: patients who accepted phase I procedures (IP and those who accepted phase II (IIP. To better understand the motivations behind the refusal of II phase procedures, we asked the patients belonging to both the IP group and “no surgery” group to indicate the main reason that influenced their decision to avoid II phase procedures. We also monitored and compared five parameters of postoperative discomfort: pain, painkiller assumption, length of hospitalization, foreign body sensation, and diet assumption following IP and IIP procedures. Results. The main reason to avoid IIP procedures was the concern of a more severe postoperative discomfort. Comparison of the postoperative discomfort following IP versus IIP procedures showed that the former scored worse in 4 out of 5 parameters analyzed. Conclusion. IIP procedures produce less postoperative discomfort. IIP procedures, namely, orthognathic surgery, should be the first choice intervention in patients affected by OSAS and dentoskeletal malformation.

  19. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  20. Skill qualifications in pediatric minimally invasive surgery.

    Science.gov (United States)

    Iwanaka, Tadashi; Morikawa, Yasuhide; Yamataka, Atsuyuki; Nio, Masaki; Segawa, Osamu; Kawashima, Hiroshi; Sato, Masahito; Terakura, Hirotsugu; Take, Hiroshi; Hirose, Ryuichiro; Yagi, Makoto

    2011-07-01

    In 2006, The Japanese Society of Pediatric Endoscopic Surgeons devised a plan to develop a pediatric endoscopic surgical skill qualification (ESSQ) system. This system is controlled by The Japan Society for Endoscopic Surgery. The standard requirement for skills qualification is the ability of each applicant to complete common types of laparoscopic surgery. The main goal of the system is to decrease complications of laparoscopic surgery by evaluating the surgical skills of each applicant and subsequently certify surgeons with adequate skills to perform laparoscopic operations safely. A committee of pediatric ESSQ created a checklist to assess the applicant's laparoscopic surgical skills. Skills are assessed in a double-blinded fashion by evaluating an unedited video recording of a fundoplication for pediatric gastroesophageal reflux disease. The initial pediatric ESSQ system was started in 2008. In 2008 and 2009, respectively, 9 out of 17 (53%) and 6 out of 12 (50%) applicants were certified as expert pediatric laparoscopic surgeons. Our ultimate goal is to provide safe and appropriate pediatric minimally invasive procedures and to avoid severe complications. To prove the predictive validity of this system, a survey of the outcomes of operations performed by certified pediatric surgeons is required.

  1. A review of medical robotics for minimally invasive soft tissue surgery.

    Science.gov (United States)

    Dogangil, G; Davies, B L; Rodriguez y Baena, F

    2010-01-01

    This paper provides an overview of recent trends and developments in medical robotics for minimally invasive soft tissue surgery, with a view to highlight some of the issues posed and solutions proposed in the literature. The paper includes a thorough review of the literature, which focuses on soft tissue surgical robots developed and published in the last five years (between 2004 and 2008) in indexed journals and conference proceedings. Only surgical systems were considered; imaging and diagnostic devices were excluded from the review. The systems included in this paper are classified according to the following surgical specialties: neurosurgery; eye surgery and ear, nose, and throat (ENT); general, thoracic, and cardiac surgery; gastrointestinal and colorectal surgery; and urologic surgery. The systems are also cross-classified according to their engineering design and robotics technology, which is included in tabular form at the end of the paper. The review concludes with an overview of the field, along with some statistical considerations about the size, geographical spread, and impact of medical robotics for soft tissue surgery today.

  2. Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract surgery.

    Science.gov (United States)

    Peng, Jie; Zhang, Qi; Jin, Hai-Ying; Lu, Wu-Yi; Zhao, Pei-Quan

    2016-01-01

    To compare the results of non-mydriatic ultra-wide field imaging system, mydriatic slit-lamp lens (Volk +90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery. Non-mydriatic images were obtained with an Optomap panoramic 200Tx (Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist. A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day. A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens. In total, 160 patients (184 eyes) were examined, and 66, 69, and 75 cases of retinal lesion(s) were identified using the Optomap 200Tx, slit-lamp lens, and Goldmann three-mirror contact lens, respectively. In 13 cases, fundus changes were sight-threatening. The results obtained by Optomap 200Tx examination and by mydriatic slit-lamp lens examination have good consistency (P=0.375, Kappa=0.942). The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx (P=0.004, Kappa=0.897) and mydriatic slit-lamp lens examination (P=0.031, Kappa=0.932). Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss. Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.

  3. Impact of robotic general surgery course on participants' surgical practice.

    Science.gov (United States)

    Buchs, Nicolas C; Pugin, François; Volonté, Francesco; Hagen, Monika E; Morel, Philippe

    2013-06-01

    Courses, including lectures, live surgery, and hands-on session, are part of the recommended curriculum for robotic surgery. However, for general surgery, this approach is poorly reported. The study purpose was to evaluate the impact of robotic general surgery course on the practice of participants. Between 2007 and 2011, 101 participants attended the Geneva International Robotic Surgery Course, held at the University Hospital of Geneva, Switzerland. This 2-day course included theory lectures, dry lab, live surgery, and hands-on session on cadavers. After a mean of 30.1 months (range, 2-48), a retrospective review of the participants' surgical practice was performed using online research and surveys. Among the 101 participants, there was a majority of general (58.4 %) and colorectal surgeons (10.9 %). Other specialties included urologists (7.9 %), gynecologists (6.9 %), pediatric surgeons (2 %), surgical oncologists (1 %), engineers (6.9 %), and others (5.9 %). Data were fully recorded in 99 % of cases; 46 % of participants started to perform robotic procedures after the course, whereas only 6.9 % were already familiar with the system before the course. In addition, 53 % of the attendees worked at an institution where a robotic system was already available. All (100 %) of participants who started a robotic program after the course had an available robotic system at their institution. A course that includes lectures, live surgery, and hands-on session with cadavers is an effective educational method for spreading robotic skills. However, this is especially true for participants whose institution already has a robotic system available.

  4. Tennis elbow surgery

    Science.gov (United States)

    Lateral epicondylitis - surgery; Lateral tendinosis - surgery; Lateral tennis elbow - surgery ... Surgery to repair tennis elbow is often an outpatient surgery. This means you will not stay in the hospital overnight. You will be given ...

  5. Do Scoring Systems Help in Predicting Survival Following Ruptured Abdominal Aortic Aneurysm Surgery?

    Science.gov (United States)

    Gatt, Marcel; Goldsmith, Paul; Martinez, Marcos; Barandiaran, Jesus; Grover, Kartikae; El-Barghouti, Naif; Perry, Eugene P

    2009-01-01

    INTRODUCTION The aim of this study was to assess the value of the Hardman Index and the Glasgow Aneurysm Score in predicting postoperative mortality in patients with ruptured abdominal aortic aneurysm (rAAA), and to assess the correlation between the two. PATIENTS AND METHODS Patients admitted with rAAA were identified from a hospital database. Hospital records were reviewed and a retrospective Hardman Index and Glasgow Aneurysm Score was calculated. Poor postoperative prognosis was considered at a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3. RESULTS A total of 96 patients with a median age of 77.5 years (interquartile range, 71–83 years) and a male:female ratio of 2:1 were identified. Of these, 37 patients were not offered surgery and this was associated with 100% mortality. Of the 59 operated patients, 36 (61%) patients died postoperatively. Operated patients had a median Glasgow Aneurysm Score of 91 (interquartile range, 77–101) and a Hardman Index of 2 (interquartile range, 1–2). In this group, a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3 was not associated with mortality (P = 0.10 and P = 0.79, respectively). Correlation between the scoring systems was poor (+0.42 τb). CONCLUSIONS The scoring systems assessed did not help predict the outcome of rAAA surgery, and correlated poorly with each other. They do not aid clinical judgement. PMID:19102824

  6. Making Safe Surgery Affordable: Design of a Surgical Drill Cover System for Scale.

    Science.gov (United States)

    Buchan, Lawrence L; Black, Marianne S; Cancilla, Michael A; Huisman, Elise S; Kooyman, Jeremy J R; Nelson, Scott C; OʼHara, Nathan N; OʼBrien, Peter J; Blachut, Piotr A

    2015-10-01

    Many surgeons in low-resource settings do not have access to safe, affordable, or reliable surgical drilling tools. Surgeons often resort to nonsterile hardware drills because they are affordable, robust, and efficient, but they are impossible to sterilize using steam. A promising alternative is to use a Drill Cover system (a sterilizable fabric bag plus surgical chuck adapter) so that a nonsterile hardware drill can be used safely for surgical bone drilling. Our objective was to design a safe, effective, affordable Drill Cover system for scale in low-resource settings. We designed our device based on feedback from users at Mulago Hospital (Kampala, Uganda) and focused on 3 main aspects. First, the design included a sealed barrier between the surgical field and hardware drill that withstands pressurized fluid. Second, the selected hardware drill had a maximum speed of 1050 rpm to match common surgical drills and reduce risk of necrosis. Third, the fabric cover was optimized for ease of assembly while maintaining a sterile technique. Furthermore, with the Drill Cover approach, multiple Drill Covers can be provided with a single battery-powered drill in a "kit," so that the drill can be used in back-to-back surgeries without requiring immediate sterilization. The Drill Cover design presented here provides a proof-of-concept for a product that can be commercialized, produced at scale, and used in low-resource settings globally to improve access to safe surgery.

  7. Mohs micrographic surgery

    Science.gov (United States)

    Skin cancer - Mohs surgery; Basal cell skin cancer - Mohs surgery; Squamous cell skin cancer - Mohs surgery ... Mohs surgery usually takes place in the doctor's office. The surgery is started early in the morning and is ...

  8. [Thymus surgery in a general surgery department].

    Science.gov (United States)

    Mega, Raquel; Coelho, Fátima; Pimentel, Teresa; Ribero, Rui; Matos, Novo de; Araújo, António

    2005-01-01

    Evaluation of thymectomy cases between 1990-2003, in a General Surgery Department. Evaluation of the therapeutic efficacy in Miastenia Gravis patients. Retrospective study based on evaluation of data from Serviço de Cirurgia, Neurologia and Consult de Neurology processes, between 1990-2003, of 15 patients submitted to total thymectomy. 15 patients, aged 17 to 72, 11 female and 4 male. Miastenia Gravis was the main indication for surgery, for uncontrollable symptoms or suspicion of thymoma. In patients with myasthenia, surgery was accomplish after compensation of symptoms. There weren't post-surgery complications. Pathology were divided in thymic hyperplasia and thymoma. Miastenia patients have there symptoms diminished or stable with reduction or cessation of medical therapy. Miastenia was the most frequent indication for thymectomy. Surgery was good results, with low morbimortality, as long as the protocols are respected.

  9. [Comparison of robotic surgery documentary in gynecological cancer].

    Science.gov (United States)

    Vargas-Hernández, Víctor Manuel

    2012-01-01

    Robotic surgery is a surgical technique recently introduced, with major expansion and acceptance among the medical community is currently performed in over 1,000 hospitals around the world and in the management of gynecological cancer are being developed comprehensive programs for implementation. The objectives of this paper are to review the scientific literature on robotic surgery and its application in gynecological cancer to verify its safety, feasibility and efficacy when compared with laparoscopic surgery or surgery classical major surgical complications, infections are more common in traditional radical surgery compared with laparoscopic or robotic surgery and with these new techniques surgical and staying hospital are lesser than the former however, the disadvantages are the limited number of robot systems, their high cost and applies only in specialized centers that have with equipment and skilled surgeons. In conclusion robotic surgery represents a major scientific breakthrough and surgical management of gynecological cancer with better results to other types of conventional surgery and is likely in the coming years is become its worldwide.

  10. Follow the light: projector-based augmented reality intracorporeal system for laparoscopic surgery.

    Science.gov (United States)

    Edgcumbe, Philip; Singla, Rohit; Pratt, Philip; Schneider, Caitlin; Nguan, Christopher; Rohling, Robert

    2018-04-01

    A projector-based augmented reality intracorporeal system (PARIS) is presented that includes a miniature tracked projector, tracked marker, and laparoscopic ultrasound (LUS) transducer. PARIS was developed to improve the efficacy and safety of laparoscopic partial nephrectomy (LPN). In particular, it has been demonstrated to effectively assist in the identification of tumor boundaries during surgery and to improve the surgeon's understanding of the underlying anatomy. PARIS achieves this by displaying the orthographic projection of the cancerous tumor on the kidney's surface. The performance of PARIS was evaluated in a user study with two surgeons who performed 32 simulated robot-assisted partial nephrectomies. They performed 16 simulated partial nephrectomies with PARIS for guidance and 16 simulated partial nephrectomies with only an LUS transducer for guidance. With PARIS, there was a significant reduction [30% ([Formula: see text])] in the amount of healthy tissue excised and a trend toward a more accurate dissection around the tumor and more negative margins. The combined point tracking and reprojection root-mean-square error of PARIS was 0.8 mm. PARIS' proven ability to improve key metrics of LPN surgery and qualitative feedback from surgeons about PARIS supports the hypothesis that it is an effective surgical navigation tool.

  11. Cataract Surgery Outcomes in Uveitis: The Multicenter Uveitis Steroid Treatment Trial.

    Science.gov (United States)

    Sen, H Nida; Abreu, Francis M; Louis, Thomas A; Sugar, Elizabeth A; Altaweel, Michael M; Elner, Susan G; Holbrook, Janet T; Jabs, Douglas A; Kim, Rosa Y; Kempen, John H

    2016-01-01

    To assess the visual outcomes of cataract surgery in eyes that received fluocinolone acetonide implant or systemic therapy with oral corticosteroids and immunosuppression during the Multicenter Uveitis Steroid Treatment (MUST) Trial. Nested prospective cohort study of patients enrolled in a randomized clinical trial. Patients that underwent cataract surgery during the first 2 years of follow-up in the MUST Trial. Visual outcomes of cataract surgery were evaluated 3, 6, and 9 months after surgery using logarithmic visual acuity charts. Change in visual acuity over time was assessed using a mixed-effects model. Best-corrected visual acuity. After excluding eyes that underwent cataract surgery simultaneously with implant surgery, among the 479 eyes in the MUST Trial, 117 eyes (28 eyes in the systemic, 89 in the implant group) in 82 patients underwent cataract surgery during the first 2 years of follow-up. Overall, visual acuity increased by 23 letters from the preoperative visit to the 3-month visit (95% confidence interval [CI], 17-29 letters; P uveitis onset, and hypotony were associated with worse preoperative visual acuity (P 0.05, test of interaction). After adjusting for other risk factors, there was no significant difference in the improvement in visual acuity between the 2 treatment groups (implant vs. systemic therapy, 2 letters; 95% CI, -10 to 15 letters; P = 0.70). Cataract surgery resulted in substantial, sustained, and similar visual acuity improvement in the eyes of patients with uveitis treated with the fluocinolone acetonide implant or standard systemic therapy. Published by Elsevier Inc.

  12. Morbidity and mortality of complex spine surgery

    DEFF Research Database (Denmark)

    Karstensen, Sven; Bari, Tanvir; Gehrchen, Martin

    2016-01-01

    requiring revision. METHODS: All patients undergoing spinal surgery at an academic tertiary referral center in the study period were prospectively included. The newest version of SAVES system was used, and a research coordinator collected all intraoperative and perioperative data prospectively. Once a week...... adverse events (AEs). PURPOSE: This study aimed to determine the mortality and examine the incidence of morbidity in patients undergoing complex spinal surgery, including pediatric patients, and to validate the SAVES system in a European population. STUDY DESIGN: A prospective, consecutive cohort study...

  13. Use of robotics in colon and rectal surgery.

    Science.gov (United States)

    Pucci, Michael J; Beekley, Alec C

    2013-03-01

    The pace of innovation in the field of surgery continues to accelerate. As new technologies are developed in combination with industry and clinicians, specialized patient care improves. In the field of colon and rectal surgery, robotic systems offer clinicians many alternative ways to care for patients. From having the ability to round remotely to improved visualization and dissection in the operating room, robotic assistance can greatly benefit clinical outcomes. Although the field of robotics in surgery is still in its infancy, many groups are actively investigating technologies that will assist clinicians in caring for their patients. As these technologies evolve, surgeons will continue to find new and innovative ways to utilize the systems for improved patient care and comfort.

  14. [The advancement of robotic surgery--successes, failures, challenges].

    Science.gov (United States)

    Haidegger, Tamás

    2010-10-10

    Computer-integrated robotic surgery systems appeared more than twenty years ago and since then hundreds of different prototypes have been developed. Only a fraction of them have been commercialized, mostly to support neurosurgical and orthopaedic procedures.Unquestionably, the most successful one is the da Vinci surgical system, primarily deployed in urology and general laparoscopic surgery. It is developed and marketed by Intuitive Surgical Inc. (Sunnyvale, CA, USA), the only profitable company of the segment. The da Vinci made robotic surgery is known and acknowledged throughout the world, and the great results delivered convinced most of the former critics of the technology. Success derived from the well chosen business development strategy, proficiency of the developers, appropriate timing and a huge pot of luck. This article presents the most important features of the da Vinci system, the history of development along with its medical, economical and financial aspects, and seeks the answer why this particular system became successful.

  15. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require one or more ... find out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment ...

  16. [Thoracic surgery for patients with bronchial asthma].

    Science.gov (United States)

    Iyoda, A; Satoh, Y

    2012-07-01

    Thoracic surgery poses a risk for complications in the respiratory system. In particular, for patients with bronchial asthma, we need to care for perioperative complications because it is well known that these patients frequently have respiratory complications after surgery, and they may have bronchial spasms during surgery. If we can get good control of their bronchial asthma, we can usually perform surgery for these patients without limitations. For safe postoperative care, it is desirable that these patients have stable asthma conditions that are well-controlled before surgery, as thoracic surgery requires intrabronchial intubation for anesthesia and sometimes bronchial resection. These stimulations to the bronchus do not provide for good conditions because of the risk of bronchial spasm. Therefore, we should use the same agents that are used to control bronchial asthma if it is already well controlled. If it is not, we have to administer a β₂ stimulator, aminophylline, or steroidal agents for good control. Isoflurane or sevoflurane are effective for the safe control of anesthesia during surgery, and we should use a β₂ stimulator, with or without inhalation, or steroidal agents after surgery. It is important to understand that we can perform thoracic surgery for asthma patients if we can provide perioperative control of bronchial asthma, although these patients still have severe risks.

  17. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  18. Microscope-integrated optical coherence tomography for image-aided positioning of glaucoma surgery.

    Science.gov (United States)

    Li, Xiqi; Wei, Ling; Dong, Xuechuan; Huang, Ping; Zhang, Chun; He, Yi; Shi, Guohua; Zhang, Yudong

    2015-07-01

    Most glaucoma surgeries involve creating new aqueous outflow pathways with the use of a small surgical instrument. This article reported a microscope-integrated, real-time, high-speed, swept-source optical coherence tomography system (SS-OCT) with a 1310-nm light source for glaucoma surgery. A special mechanism was designed to produce an adjustable system suitable for use in surgery. A two-graphic processing unit architecture was used to speed up the data processing and real-time volumetric rendering. The position of the surgical instrument can be monitored and measured using the microscope and a grid-inserted image of the SS-OCT. Finally, experiments were simulated to assess the effectiveness of this integrated system. Experimental results show that this system is a suitable positioning tool for glaucoma surgery.

  19. Metabolic phenotype-microRNA data fusion analysis of the systemic consequences of Roux-en-Y gastric bypass surgery.

    Science.gov (United States)

    Wu, Q; Li, J V; Seyfried, F; le Roux, C W; Ashrafian, H; Athanasiou, T; Fenske, W; Darzi, A; Nicholson, J K; Holmes, E; Gooderham, N J

    2015-07-01

    Bariatric surgery offers sustained marked weight loss and often remission of type 2 diabetes, yet the mechanisms of establishment of these health benefits are not clear. We mapped the coordinated systemic responses of gut hormones, the circulating miRNAome and the metabolome in a rat model of Roux-en-Y gastric bypass (RYGB) surgery. The response of circulating microRNAs (miRNAs) to RYGB was striking and selective. Analysis of 14 significantly altered circulating miRNAs within a pathway context was suggestive of modulation of signaling pathways including G protein signaling, neurodegeneration, inflammation, and growth and apoptosis responses. Concomitant alterations in the metabolome indicated increased glucose transport, accelerated glycolysis and inhibited gluconeogenesis in the liver. Of particular significance, we show significantly decreased circulating miRNA-122 levels and a more modest decline in hepatic levels, following surgery. In mechanistic studies, manipulation of miRNA-122 levels in a cell model induced changes in the activity of key enzymes involved in hepatic energy metabolism, glucose transport, glycolysis, tricarboxylic acid cycle, pentose phosphate shunt, fatty-acid oxidation and gluconeogenesis, consistent with the findings of the in vivo surgery-mediated responses, indicating the powerful homeostatic activity of the miRNAs. The close association between energy metabolism, neuronal signaling and gut microbial metabolites derived from the circulating miRNA, plasma, urine and liver metabolite and gut hormone correlations further supports an enhanced gut-brain signaling, which we suggest is hormonally mediated by both traditional gut hormones and miRNAs. This transomic approach to map the crosstalk between the circulating miRNAome and metabolome offers opportunities to understand complex systems biology within a disease and interventional treatment setting.

  20. Systematic review of the surgery-first approach in orthognathic surgery

    Directory of Open Access Journals (Sweden)

    Chiung Shing Huang

    2014-08-01

    Full Text Available The surgery-first approach in orthognathic surgery has recently created a broader interest in completely eliminating time-consuming preoperative orthodontic treatment. Available evidence on the surgery-first approach should be appraised to support its use in orthognathic surgery. A MEDLINE search using the keywords "surgery first" and "orthognathic surgery" was conducted to select studies using the surgery-first approach. We also manually searched the reference list of the selected keywords to include articles not selected by the MEDLINE search. The search identified 18 articles related to the surgery-first approach. There was no randomized controlled clinical trial. Four papers were excluded as the content was only personal opinion or basic scientific research. Three studies were retrospective cohort studies in nature. The other 11 studies were case reports. For skeletal Class III surgical correction, the final long-term outcomes for maxillofacial and dental relationship were not significantly different between the surgery-first approach and the orthodontics-first approach in transverse (e.g., intercanine or intermolar width dimension, vertical (e.g., anterior open bite, lower anterior facial height dimension, and sagittal (e.g., anterior-posterior position of pogonion and lower incisors dimension. Total treatment duration was substantially shorter in cases of surgery-first approach use. In conclusion, most published studies related to the surgery-first approach were mainly on orthognathic correction of skeletal Class III malocclusion. Both the surgery-first approach and orthodontics-first approach had similar long-term outcomes in dentofacial relationship. However, the surgery-first approach had shorter treatment time.

  1. Corneal polarimetry after LASIK refractive surgery

    Science.gov (United States)

    Bueno, Juan M.; Berrio, Esther; Artal, Pablo

    2006-01-01

    Imaging polarimetry provides spatially resolved information on the polarization properties of a system. In the case of the living human eye, polarization could be related to the corneal biomechanical properties, which vary from the normal state as a result of surgery or pathologies. We have used an aberro-polariscope, which we recently developed, to determine and to compare the spatially resolved maps of polarization parameters across the pupil between normal healthy and post-LASIK eyes. The depolarization distribution is not uniform across the pupil, with post-surgery eyes presenting larger levels of depolarization. While retardation increases along the radius in normal eyes, this pattern becomes irregular after LASIK refractive surgery. The maps of slow axis also differ in normal and post-surgery eyes, with a larger disorder in post-LASIK eyes. Since these changes in polarization indicate subtle structural modifications of the cornea, this approach can be useful in a clinical environment to follow the biomechanical and optical changes of the cornea after refractive surgery or for the early diagnosis of different corneal pathologies.

  2. Incisional Recurrences After Endometrial Cancer Surgery.

    Science.gov (United States)

    Bogani, Giorgio; Dowdy, Sean C; Cliby, William A; Gostout, Bobbie S; Kumar, Sanjeev; Ghezzi, Fabio; Multinu, Francesco; Mariani, Andrea

    2015-11-01

    The aim of the present study was to estimate the incisional recurrence (IR) rate after endometrial cancer (EC) staging surgery and analyze characteristics of affected patients. We retrospectively searched for patients with EC at 2 institutions and analyzed the occurrence of IR after open, laparoscopic, or robotic surgery. Additionally, a review of the literature was performed. Out of 2,636 patients with EC, 1,732 (65.7%), 461 (17.5%), and 443 (16.8%) had open, laparoscopic, and robotic surgery, respectively. Only 3 patients (0.11%) had IR, all after open surgery. Additionally, 38 cases of IR were identified from the literature. Patients with non-isolated IR had worse overall survival than patients with isolated IR (p=0.04). Among this latter group, combined treatments may be associated with improved survival outcome. IR after EC surgery is rare and may occur after minimally-invasive or open operations. Combination of local and systemic treatments may provide favorable outcomes for patients with isolated IR. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  3. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  4. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  5. Turbinate surgery

    Science.gov (United States)

    Turbinectomy; Turbinoplasty; Turbinate reduction; Nasal airway surgery; Nasal obstruction - turbinate surgery ... There are several types of turbinate surgery: Turbinectomy: All or ... This can be done in several different ways, but sometimes a ...

  6. Pre-operative evaluation for thorax surgery

    International Nuclear Information System (INIS)

    Silva Luis, Saenz; Morales, Oscar Alberto

    2002-01-01

    A pre-operative analysis of the function of the breathing system is made in the patient that will be taken to thorax surgery. The paper includes risk factors, pre-operative clinical evaluation and of breathing and cardiovascular system

  7. Future robotic platforms in urologic surgery: Recent Developments

    Science.gov (United States)

    Herrell, S. Duke; Webster, Robert; Simaan, Nabil

    2014-01-01

    Purpose of review To review recent developments at Vanderbilt University of new robotic technologies and platforms designed for minimally invasive urologic surgery and their design rationale and potential roles in advancing current urologic surgical practice. Recent findings Emerging robotic platforms are being developed to improve performance of a wider variety of urologic interventions beyond the standard minimally invasive robotic urologic surgeries conducted presently with the da Vinci platform. These newer platforms are designed to incorporate significant advantages of robotics to improve the safety and outcomes of transurethral bladder surgery and surveillance, further decrease the invasiveness of interventions by advancing LESS surgery, and allow for previously impossible needle access and ablation delivery. Summary Three new robotic surgical technologies that have been developed at Vanderbilt University are reviewed, including a robotic transurethral system to enhance bladder surveillance and TURBT, a purpose-specific robotic system for LESS, and a needle sized robot that can be used as either a steerable needle or small surgeon-controlled micro-laparoscopic manipulator. PMID:24253803

  8. Variable Operative Experience in Hand Surgery for Plastic Surgery Residents.

    Science.gov (United States)

    Silvestre, Jason; Lin, Ines C; Levin, Lawrence Scott; Chang, Benjamin

    Efforts to standardize hand surgery training during plastic surgery residency remain challenging. We analyze the variability of operative hand experience at U.S. plastic surgery residency programs. Operative case logs of chief residents in accredited U.S. plastic surgery residency programs were analyzed (2011-2015). Trends in fold differences of hand surgery case volume between the 10th and 90th percentiles of residents were assessed graphically. Percentile data were used to calculate the number of residents achieving case minimums in hand surgery for 2015. Case logs from 818 plastic surgery residents were analyzed of which a minority were from integrated (35.7%) versus independent/combined (64.3%) residents. Trend analysis of fold differences in case volume demonstrated decreasing variability among procedure categories over time. By 2015, fold differences for hand reconstruction, tendon cases, nerve cases, arthroplasty/arthrodesis, amputation, arterial repair, Dupuytren release, and neoplasm cases were below 10-fold. Congenital deformity cases among independent/combined residents was the sole category that exceeded 10-fold by 2015. Percentile data suggested that approximately 10% of independent/combined residents did not meet case minimums for arterial repair and congenital deformity in 2015. Variable operative experience during plastic surgery residency may limit adequate exposure to hand surgery for certain residents. Future studies should establish empiric case minimums for plastic surgery residents to ensure hand surgery competency upon graduation. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Adverse Effects of Smoking on Outcomes of Orthopaedic Surgery

    OpenAIRE

    Sheung-tung Ho

    2017-01-01

    Smoking has many adverse effects on the musculoskeletal system, particularly on the outcomes after orthopaedic surgery. Smoking is associated with surgical site infection and postoperative wound complications after spine surgery, total joint arthroplasty, and fracture fixation; nonunion after spinal fusion, ankle fusion, osteotomy, and internal fixation and bone grafting for scaphoid nonunion; worse outcomes after lumbar disc prolapse, spinal stenosis, and cervical myelopathy surgery; peripro...

  10. Bariatric Surgery

    Science.gov (United States)

    ... often. Each type of surgery has advantages and disadvantages. Bariatric Surgery Benefits Bariatric surgery can improve many ... Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  11. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  12. Early experience with the da Vinci® surgical system robot in gynecological surgery at King Abdulaziz University Hospital

    Directory of Open Access Journals (Sweden)

    Sait KH

    2011-07-01

    Full Text Available Khalid H SaitObstetrics and Gynecology Department, Faculty of Medicine, Gynecology Oncology Unit, King Abdulaziz University Hospital, Jeddah, Saudi ArabiaBackground: The purpose of this study was to review our experience and the challenges of using the da Vinci® surgical system robot during gynecological surgery at King Abdulaziz University Hospital.Methods: A retrospective study was conducted to review all cases of robot-assisted gynecologic surgery performed at our institution between January 2008 and December 2010. The patients were reviewed for indications, complications, length of hospital stay, and conversion rate, as well as console and docking times.Results: Over the three-year period, we operated on 35 patients with benign or malignant conditions using the robot for a total of 62 surgical procedures. The docking times averaged seven minutes. The mean console times for simple hysterectomy, bilateral salpingo-oophorectomy, and bilateral pelvic lymphadenectomy were 125, 47, and 62 minutes, respectively. In four patients, laparoscopic procedures were converted to open procedures, giving a conversion rate of 6.5%. All of the conversions were among the first 15 procedures performed. The average hospital stay was 3 days. Complications occurred in five patients (14%, and none were directly related to the robotic system.Conclusion: Our early experience with the robot show that with proper training of the robotic team, technical difficulty with the robotic system is limited. There is definitely a learning curve that requires performance of gynecological surgical procedures using the robot.Keywords: da Vinci robot, gynecological surgery, laparoscopy

  13. Acute leukaemoid reaction following cardiac surgery

    Directory of Open Access Journals (Sweden)

    Webb Stephen T

    2007-01-01

    Full Text Available Abstract Chronic myelomonocytic leukaemia is an atypical myeloproliferative disorder with a natural history of progression to acute myeloid leukaemia, a complex and poorly understood response by the bone marrow to stress. Cardiac surgery activates many inflammatory cascades and may precipitate a systemic inflammatory response syndrome. We present a case of undiagnosed chronic myelomonocytic leukaemia who developed rapidly fatal multi-organ dysfunction following cardiac surgery due to an acute leukaemoid reaction.

  14. Repetitive endoscopic sinus surgery failure: a role for radical surgery?

    NARCIS (Netherlands)

    Videler, Ward J. M.; Wreesmann, Volkert B.; van der Meulen, Freerk W.; Knegt, Paul P.; Fokkens, Wytske J.

    2006-01-01

    OBJECTIVES: Endoscopic sinus surgery (ESS) is considered to be the golden standard for surgery in patients with chronic rhinosinusitis and nasal polyposis. However, there is still a small group of patients unresponsive despite repetitive surgery. Radical surgery aimed at reduction of the

  15. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  16. TMJ surgery following orthognathic surgery: A case series

    Directory of Open Access Journals (Sweden)

    C. Politis

    2018-06-01

    Full Text Available Orthognathic surgery may affect or cause temporomandibular joint (TMJ complaints. This study evaluated the need for TMJ surgery after orthognathic surgery.A retrospective cohort study was carried out on 630 consecutive patients undergoing at least a Le Fort I or bilateral sagittal split osteotomy (BSSO. The mean follow-up time was 2,3 years. Clinical, surgical and radiographic findings were collected.Ten of the 630 patients (1.6% had additional arthroscopic TMJ-surgery in one (9 or in both (1 joints because of internal derangement, resistant to conventional therapy. Only 4/10 patients had successful outcomes following arthroscopic surgery. One patient with unsuccessful outcome required multiple additional open TMJ-surgeries, all remaining ineffective to relieve pain and restricted mouth opening. If arthroscopy failed to relieve symptoms (5/10 patients, further conservative management was opted. Arthroscopy seemed effective mainly in patients without pre-existing TMJ complaints.A further five of the 630 patients (0.8% required more treatment because of bilateral postoperative condylar resorption, but none of them required TMJ-surgery.In contrast to patients with bilateral condylar resorption where the skeletal relapse remained the issue of concern, patients with internal derangement/osteoarthrosis exhibited major occlusal changes in one patient only (1/10, leaving the TMJ complaints as the main concern. Keywords: Sagittal split osteotomy, Le Fort I osteotomy, Orthognathic surgery, Condylar remodelling, Condylar resorption, Osteoarthrosis, Internal derangement, Relapse, Arthroscopy

  17. Computational surgery and dual training computing, robotics and imaging

    CERN Document Server

    Bass, Barbara; Berceli, Scott; Collet, Christophe; Cerveri, Pietro

    2014-01-01

    This critical volume focuses on the use of medical imaging, medical robotics, simulation, and information technology in surgery. It offers a road map for computational surgery success,  discusses the computer-assisted management of disease and surgery, and provides a rational for image processing and diagnostic. This book also presents some advances on image-driven intervention and robotics, as well as evaluates models and simulations for a broad spectrum of cancers as well as cardiovascular, neurological, and bone diseases. Training and performance analysis in surgery assisted by robotic systems is also covered. This book also: ·         Provides a comprehensive overview of the use of computational surgery and disease management ·         Discusses the design and use of medical robotic tools for orthopedic surgery, endoscopic surgery, and prostate surgery ·         Provides practical examples and case studies in the areas of image processing, virtual surgery, and simulation traini...

  18. Hemodilution, kidney dysfunction and cardiac surgery

    Directory of Open Access Journals (Sweden)

    Fabio Papa Taniguchi

    2009-03-01

    Full Text Available Hemodilution has been used in cardiac surgery to reduce blood viscosity and peripheral vascular resistance, decrease the need for blood transfusions, attenuate the risk of transfusions and diminish systemic inflammatory response syndrome and hospital costs. The lowest hematocrit level during cardiopulmonary bypass has been stated as 20%. However, severe hemodilution in cardiopulmonary bypass for patients undergoing cardiac surgery has been recognized as a risk factor for hospital deaths and reduced long-term survival. The introduction of normothermia restarted the debate about the lowest acceptable hematocrit during cardiopulmonary bypass. The objective of this review is to evaluate hemodilution during cardiac surgery as a risk factor for the development of post-operative acute renal failure.

  19. Graphic and haptic simulation system for virtual laparoscopic rectum surgery.

    Science.gov (United States)

    Pan, Jun J; Chang, Jian; Yang, Xiaosong; Zhang, Jian J; Qureshi, Tahseen; Howell, Robert; Hickish, Tamas

    2011-09-01

    Medical simulators with vision and haptic feedback techniques offer a cost-effective and efficient alternative to the traditional medical trainings. They have been used to train doctors in many specialties of medicine, allowing tasks to be practised in a safe and repetitive manner. This paper describes a virtual-reality (VR) system which will help to influence surgeons' learning curves in the technically challenging field of laparoscopic surgery of the rectum. Data from MRI of the rectum and real operation videos are used to construct the virtual models. A haptic force filter based on radial basis functions is designed to offer realistic and smooth force feedback. To handle collision detection efficiently, a hybrid model is presented to compute the deformation of intestines. Finally, a real-time cutting technique based on mesh is employed to represent the incision operation. Despite numerous research efforts, fast and realistic solutions of soft tissues with large deformation, such as intestines, prove extremely challenging. This paper introduces our latest contribution to this endeavour. With this system, the user can haptically operate with the virtual rectum and simultaneously watch the soft tissue deformation. Our system has been tested by colorectal surgeons who believe that the simulated tactile and visual feedbacks are realistic. It could replace the traditional training process and effectively transfer surgical skills to novices. Copyright © 2011 John Wiley & Sons, Ltd.

  20. Heart bypass surgery

    Science.gov (United States)

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  1. Approach to intraoperative electromagnetic navigation in orthognathic surgery: A phantom skull based trial.

    Science.gov (United States)

    Berger, Moritz; Kallus, Sebastian; Nova, Igor; Ristow, Oliver; Eisenmann, Urs; Dickhaus, Hartmut; Kuhle, Reinald; Hoffmann, Jürgen; Seeberger, Robin

    2015-11-01

    Intraoperative guidance using electromagnetic navigation is an upcoming method in maxillofacial surgery. However, due to their unwieldy structures, especially the line-of-sight problem, optical navigation devices are not used for daily orthognathic surgery. Therefore, orthognathic surgery was simulated on study phantom skulls, evaluating the accuracy and handling of a new electromagnetic tracking system. Le-Fort I osteotomies were performed on 10 plastic skulls. Orthognathic surgical planning was done in the conventional way using plaster models. Accuracy of the gold standard, splint-based model surgery versus an electromagnetic tracking system was evaluated by measuring the actual maxillary deviation using bimaxillary splints and preoperative and postoperative cone beam computer tomography imaging. The distance of five anatomical marker points were compared pre- and postoperatively. The electromagnetic tracking system was significantly more accurate in all measured parameters compared with the gold standard using bimaxillary splints (p orthognathic surgery to 0.3 mm on average. The data of this preliminary study shows a high level of accuracy in surgical orthognathic performance using electromagnetic navigation, and may offer greater precision than the conventional plaster model surgery with bimaxillary splints. This preliminary work shows great potential for the establishment of an intraoperative electromagnetic navigation system for maxillofacial surgery. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Systems innovation model: an integrated interdisciplinary team approach pre- and post-bariatric surgery at a veterans affairs (VA) medical center.

    Science.gov (United States)

    Eisenberg, Dan; Lohnberg, Jessica A; Kubat, Eric P; Bates, Cheryl C; Greenberg, Lauren M; Frayne, Susan M

    2017-04-01

    Provision of bariatric surgery in the Veterans Health Administration must account for obese veterans' co-morbidity burden and the geographically dispersed location of patients relative to Veterans Affairs (VA) bariatric centers. To evaluate a collaborative, integrated, interdisciplinary bariatric team of surgeons, bariatricians, psychologists, dieticians, and physical therapists working in a hub-and-spokes care model, for pre- and post-bariatric surgery assessment and management. This is a description of an interdisciplinary clinic and bariatric program at a VA healthcare system and a report on program evaluation findings. Retrospective data of a prospective database was abstracted. For program evaluation, we abstracted charts to characterize patient data and conducted a patient survey. Since 2009, 181 veterans have undergone bariatric surgery. Referrals came from 7 western U.S. states. Mean preoperative body mass index was 46 kg/m 2 (maximum 71). Mean age was 53 years, with 33% aged>60 years; 79% were male. Medical co-morbidity included diabetes (70%), hypertension (85%), and lower back or extremity joint pain (84%). A psychiatric diagnosis was present in 58%. At 12 months, follow-up was 81% and percent excess body mass index loss was 50.5%. Among 54 sequential clinic patients completing anonymous surveys, overall satisfaction with the interdisciplinary team approach and improved quality of life were high (98% and 94%, respectively). The integrated, interdisciplinary team approach using a hub-and-spokes model is well suited to the VA bariatric surgery population, with its heavy burden of medical and mental health co-morbidity and its system of geographically dispersed patients receiving treatment at specialty centers. As the VA seeks to expand the use of bariatric surgery as an option for obese veterans, interdisciplinary models crafted to address case complexity, care coordination, and long-term outcomes should be part of policy planning efforts. Published by

  3. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  4. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  5. Facial Cosmetic Surgery

    Science.gov (United States)

    ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  6. Fast finite elements for surgery simulation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1997-01-01

    This paper discusses volumetric deformable models for modeling human body parts and organs in surgery simulation systems. These models are built using finite element models for linear elastic materials. To achieve real-time response condensation has been applied to the system stiffness matrix...

  7. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  8. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  9. The immune response of the human brain to abdominal surgery

    DEFF Research Database (Denmark)

    Forsberg, Anton; Cervenka, Simon; Jonsson Fagerlund, Malin

    2017-01-01

    OBJECTIVE: Surgery launches a systemic inflammatory reaction that reaches the brain and associates with immune activation and cognitive decline. Although preclinical studies have in part described this systemic-to-brain signaling pathway, we lack information on how these changes appear in humans....... This study examines the short- and long-term impact of abdominal surgery on the human brain immune system by positron emission tomography (PET) in relation to blood immune reactivity, plasma inflammatory biomarkers, and cognitive function. METHODS: Eight males undergoing prostatectomy under general...... anesthesia were included. Prior to surgery (baseline), at postoperative days 3 to 4, and after 3 months, patients were examined using [11C]PBR28 brain PET imaging to assess brain immune cell activation. Concurrently, systemic inflammatory biomarkers, ex vivo blood tests on immunoreactivity...

  10. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  11. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  12. Preparing for Surgery

    Science.gov (United States)

    ... Events Advocacy For Patients About ACOG Preparing for Surgery Home For Patients Search FAQs Preparing for Surgery ... Surgery FAQ080, August 2011 PDF Format Preparing for Surgery Gynecologic Problems What is the difference between outpatient ...

  13. Effects of Addition of Systemic Tramadol or Adjunct Tramadol to Lidocaine Used for Intravenous Regional Anesthesia in Patients Undergoing Hand Surgery

    Directory of Open Access Journals (Sweden)

    Abdulkadir Yektaş

    2016-01-01

    Full Text Available Intravenous regional anesthesia (IVRA is used in outpatient hand surgery as an easily applicable and cost-effective technique with clinical advantages. The present study aimed to investigate the effects of addition of systemic tramadol or adjunct tramadol to lidocaine for IVRA in patients undergoing hand surgery. American Society of Anesthesiologists (ASA I-II patients (n=60 who underwent hand surgery were included. For this purpose, only lidocaine (LDC, lidocaine+adjunct tramadol (LDC+TRA group, or lidocaine+systemic tramadol (LDC+SysTRA group was administered to the patients for IVRA and the groups were compared in terms of onset and recovery time of sensory and motor blocks, quality of anesthesia, and the degree of intraoperative and postoperative pain. The onset time of sensorial block was significantly shorter in the LDC+TRA group than that in the LDC+SysTRA group. The motor block recovery time was significantly shorter in the LDC+SysTRA group than that in the LDC+TRA and LDC groups. Administration of tramadol as an adjunct showed some clinical benefits by providing a shorter onset time of sensory and motor block, decreasing pain and analgesic requirement, and improving intraoperative conditions during IVRA. It was determined that systemic tramadol administration had no superiority.

  14. Corrective Jaw Surgery

    Science.gov (United States)

    ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  15. Does a robotic surgery approach offer optimal ergonomics to gynecologic surgeons?: a comprehensive ergonomics survey study in gynecologic robotic surgery.

    Science.gov (United States)

    Lee, Mija Ruth; Lee, Gyusung Isaiah

    2017-09-01

    To better understand the ergonomics associated with robotic surgery including physical discomfort and symptoms, factors influencing symptom reporting, and robotic surgery systems components recommended to be improved. The anonymous survey included 20 questions regarding demographics, systems, ergonomics, and physical symptoms and was completed by experienced robotic surgeons online through American Association of Gynecologic Laparoscopists (AAGL) and Society of Robotic Surgery (SRS). There were 289 (260 gynecology, 22 gynecology-oncology, and 7 urogynecology) gynecologic surgeon respondents regularly practicing robotic surgery. Statistical data analysis was performed using the t-test, χ² test, and logistic regression. One hundred fifty-six surgeons (54.0%) reported experiencing physical symptoms or discomfort. Participants with higher robotic case volume reported significantly lower physical symptom report rates (pergonomic settings not only acknowledged that the adjustments were helpful for better ergonomics but also reported a lower physical symptom rate (pergonomic settings (32.7%), took a break (33.3%) or simply ignored the problem (34%). Fingers and neck were the most common body parts with symptoms. Eye symptom complaints were significantly decreased with the Si robot (pergonomics were microphone/speaker, pedal design, and finger clutch. More than half of participants reported physical symptoms which were found to be primarily associated with confidence in managing ergonomic settings and familiarity with the system depending on the volume of robotic cases. Optimal guidelines and education on managing ergonomic settings should be implemented to maximize the ergonomic benefits of robotic surgery. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology

  16. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  17. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  18. [Computer-assisted navigation in orthognathic surgery. Application to Le Fort I osteotomy.

    Science.gov (United States)

    Benassarou, M; Benassarou, A; Meyer, C

    2013-08-05

    Computer-assisted navigation is a tool that allows the surgeon to reach intraoperatively a previously defined target. This technique can be applied to the positioning of bone fragments in orthognathic surgery. It is not used routinely yet because there are no specifically dedicated systems available on the market for this kind of surgery. The goal of our study was to describe the various systems that could be used in orthognathic surgery and to report our experience of computer-assisted surgery in the positioning of the maxilla during maxillomandibular osteotomies. Copyright © 2013. Published by Elsevier Masson SAS.

  19. Understanding how orthopaedic surgery practices generate value for healthcare systems.

    Science.gov (United States)

    Olson, Steven A; Mather, Richard C

    2013-06-01

    Orthopaedic surgery practices can provide substantial value to healthcare systems. Increasingly, healthcare administrators are speaking of the need for alignment between physicians and healthcare systems. However, physicians often do not understand what healthcare administrators value and therefore have difficulty articulating the value they create in discussions with their hospital or healthcare organization. Many health systems and hospitals use service lines as an organizational structure to track the relevant data and manage the resources associated with a particular type of care, such as musculoskeletal care. Understanding service lines and their management can be useful for orthopaedic surgeons interested in interacting with their hospital systems. We provide an overview of two basic types of value orthopaedic surgeons create for healthcare systems: financial or volume-driven benefits and nonfinancial quality or value-driven patient care benefits. We performed a search of PubMed from 1965 to 2012 using the term "service line." Of the 351 citations identified, 18 citations specifically involved the use of service lines to improve patient care in both nursing and medical journals. A service line is a structure used in healthcare organizations to enable management of a subset of activities or resources in a focused area of patient care delivery. There is not a consistent definition of what resources are managed within a service line from hospital to hospital. Physicians can positively impact patient care through engaging in service line management. There is increasing pressure for healthcare systems and hospitals to partner with orthopaedic surgeons. The peer-reviewed literature demonstrates there are limited resources for physicians to understand the value they create when attempting to negotiate with their hospital or healthcare organization. To effectively negotiate for resources to provide the best care for patients, orthopaedic surgeons need to claim and

  20. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ...

  1. Hepatic Steatosis in Morbidly Obese Patients Undergoing Gastric Bypass Surgery: Assessment With Open-System 1H-MR Spectroscopy

    NARCIS (Netherlands)

    van Werven, Jochem R.; Schreuder, Tim C. M. A.; Aarts, Edo O.; Nederveen, Aart J.; Meijer, Jos W. R.; Berends, Frits J.; Janssen, Ignace M. C.; Mulder, Chris J.; Jansen, Peter L. M.; Stoker, Jaap

    2011-01-01

    The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis

  2. Secrets of safe laparoscopic surgery: Anaesthetic and surgical considerations

    Directory of Open Access Journals (Sweden)

    Srivastava Arati

    2010-01-01

    Full Text Available In recent years, laparoscopic surgery has gained popularity in clinical practice. The key element in laparoscopic surgery is creation of pneumoperitoneum and carbon dioxide is commonly used for insufflation. This pneumoperitoneum perils the normal cardiopulmonary system to a considerable extent. Every laparoscopic surgeon should understand the consequences of pneumoperitoneum; so that its untoward effects can be averted. Pneumoperitoneum increases pressure on diaphragm, leading to its cephalic displacement and thereby decreasing venous return, which can be aggravated by the position of patient during surgery. There is no absolute contraindication of laparoscopic surgery, though we can anticipate some problems in conditions like obesity, pregnancy and previous abdominal surgery. This review discusses some aspects of the pathophysiology of carbon dioxide induced pneumoperitoneum, its consequences as well as strategies to counteract them. Also, we propose certain guidelines for safe laparoscopic surgery.

  3. Lean and Green Hand Surgery.

    Science.gov (United States)

    Van Demark, Robert E; Smith, Vanessa J S; Fiegen, Anthony

    2018-02-01

    Health care in the United States is both expensive and wasteful. The cost of health care in the United States continues to increase every year. Health care spending for 2016 is estimated at $3.35 trillion. Per capita spending ($10,345 per person) is more than twice the average of other developed countries. The United States also leads the world in solid waste production (624,700 metric tons of waste in 2011). The health care industry is second only to the food industry in annual waste production. Each year, health care facilities in the United States produce 4 billion pounds of waste (660 tons per day), with as much as 70%, or around 2.8 billion pounds, produced directly by operating rooms. Waste disposal also accounts for up to 20% of a hospital's annual environmental services budget. Since 1992, waste production by hospitals has increased annually by a rate of at least 15%, due in part to the increased usage of disposables. Reduction in operating room waste would decrease both health care costs and potential environmental hazards. In 2015, the American Association for Hand Surgery along with the American Society for Surgery of the Hand, American Society for Peripheral Nerve Surgery, and the American Society of Reconstructive Microsurgery began the "Lean and Green" surgery project to reduce the amount of waste generated by hand surgery. We recently began our own "Lean and Green" project in our institution. Using "minor field sterility" surgical principles and Wide Awake Local Anesthesia No Tourniquet (WALANT), both surgical costs and surgical waste were decreased while maintaining patient safety and satisfaction. As the current reimbursement model changes from quantity to quality, "Lean and Green" surgery will play a role in the future health care system. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. [Present situation and prospect of enhanced recovery after surgery in pancreatic surgery].

    Science.gov (United States)

    Feng, Mengyu; Zhang, Taiping; Zhao, Yupei

    2017-05-25

    Enhanced recovery after surgery is a multimodal perioperative strategy according to the evidence-based medicine and multidisciplinary collaboration, aiming to improve the restoration of functional capacity after surgery by reducing surgical stress, optimal control of pain, early oral diet and early mobilization. Compared with other sub-specialty in general surgery, pancreatic surgery is characterized by complex disease, highly difficult procedure and more postoperative complications. Accordingly, pancreatic surgery shares a slow development in enhanced recovery after surgery. In this review, the feasibility, safety, application progress, prospect and controversy of enhanced recovery after surgery in pancreatic surgery are discussed.

  5. Augmented reality as an aid in maxillofacial surgery: validation of a wearable system allowing maxillary repositioning.

    Science.gov (United States)

    Badiali, Giovanni; Ferrari, Vincenzo; Cutolo, Fabrizio; Freschi, Cinzia; Caramella, Davide; Bianchi, Alberto; Marchetti, Claudio

    2014-12-01

    We present a newly designed, localiser-free, head-mounted system featuring augmented reality as an aid to maxillofacial bone surgery, and assess the potential utility of the device by conducting a feasibility study and validation. Our head-mounted wearable system facilitating augmented surgery was developed as a stand-alone, video-based, see-through device in which the visual features were adapted to facilitate maxillofacial bone surgery. We implement a strategy designed to present augmented reality information to the operating surgeon. LeFort1 osteotomy was chosen as the test procedure. The system is designed to exhibit virtual planning overlaying the details of a real patient. We implemented a method allowing performance of waferless, augmented-reality assisted bone repositioning. In vitro testing was conducted on a physical replica of a human skull, and the augmented reality system was used to perform LeFort1 maxillary repositioning. Surgical accuracy was measured with the aid of an optical navigation system that recorded the coordinates of three reference points (located in anterior, posterior right, and posterior left positions) on the repositioned maxilla. The outcomes were compared with those expected to be achievable in a three-dimensional environment. Data were derived using three levels of surgical planning, of increasing complexity, and for nine different operators with varying levels of surgical skill. The mean error was 1.70 ± 0.51 mm. The axial errors were 0.89 ± 0.54 mm on the sagittal axis, 0.60 ± 0.20 mm on the frontal axis, and 1.06 ± 0.40 mm on the craniocaudal axis. The simplest plan was associated with a slightly lower mean error (1.58 ± 0.37 mm) compared with the more complex plans (medium: 1.82 ± 0.71 mm; difficult: 1.70 ± 0.45 mm). The mean error for the anterior reference point was lower (1.33 ± 0.58 mm) than those for both the posterior right (1.72 ± 0.24 mm) and posterior left points (2.05 ± 0.47 mm). No significant difference

  6. Computer assisted radiology and surgery. CARS 2010

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  7. Computer assisted radiology and surgery. CARS 2010

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-06-15

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  8. PET scanning in plastic and reconstructive surgery.

    Science.gov (United States)

    Liodaki, Eirini; Eirini, Liodaki; Liodakis, Emmanouil; Emmanouil, Liodakis; Papadopoulos, Othonas; Othonas, Papadopoulos; Machens, Hans-Günther; Hans-Günther, Machens; Papadopulos, Nikolaos A; Nikolaos, Papadopulos A

    2012-02-01

    In this report we highlight the use of PET scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge.

  9. Planning Strabismus Surgery: How to Avoid Pitfalls and Complications.

    Science.gov (United States)

    Aroichane, Maryam

    2016-01-01

    Good surgical results following strabismus surgery depend on several factors. In this article, detailed steps for planning strabismus surgery will be reviewed for basic horizontal strabismus surgery, vertical, and oblique muscle surgeries. The thought process behind each case will be presented to help in selecting the best surgical approach to optimize postoperative results. The surgical planning for strabismus will be developed with clinical examples from easy cases to more complex ones. Preoperative pictures of the ocular alignment are an integral part of planning surgery and help in documenting the strabismus before and after surgery. Three cases of strabismus cases will be reviewed with several key factors for planning surgery, including visual acuity, refractive error, potential for stereovision, and risk of postoperative diplopia. The most important factor is accurate orthoptic measurements. The surgical planning for each patient is detailed along with preoperative pictures. Strabismus surgery results can be improved by careful preoperative planning. The surgeon has the ability to discern potential pitfalls that can alter the surgical outcome. Surgical planning allows a dedicated time of reflection before surgery, foreseeing potential problems, and avoiding them during the surgery. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  10. Advances in endoscopic surgery for small animal reproduction.

    Science.gov (United States)

    Katic, N; Dupré, G

    2016-09-01

    Although endoscopic surgery entered its "golden era" in the mid-1980s, it is still advancing at a tremendous pace. Novel surgical techniques and devices are continuously developed and applied, and new indications (and/or contraindications) for the use of endoscopic surgery are routinely reported in the literature and subjected to systematic assessments. Although endoscopic surgery (laparoscopy in particular) has already become established as the gold standard in human medicine, it has yet to be proven as a viable alternative to open surgery in the field of veterinary medicine. The advantages of minimally invasive surgery include better intra-operative visualization, reduced postoperative pain, reduced scar formation and increased postoperative mobility. Therefore, it is reasonable to expect that the application of this will continue to expand. Small animal reproduction, a field within the broad discipline of veterinary medicine, has already recognized and begun to reap the benefits of endoscopic surgery. Herein, we retrospectively review the most recent successful novel applications of endoscopic surgery in the small animal reproduction system to provide small animal reproductive surgeons with important knowledge to help improve their own veterinarian medical practice. © 2016 Blackwell Verlag GmbH.

  11. European Association of Endoscopic Surgeons (EAES) consensus statement on the use of robotics in general surgery.

    Science.gov (United States)

    Szold, Amir; Bergamaschi, Roberto; Broeders, Ivo; Dankelman, Jenny; Forgione, Antonello; Langø, Thomas; Melzer, Andreas; Mintz, Yoav; Morales-Conde, Salvador; Rhodes, Michael; Satava, Richard; Tang, Chung-Ngai; Vilallonga, Ramon

    2015-02-01

    Following an extensive literature search and a consensus conference with subject matter experts the following conclusions can be drawn: 1. Robotic surgery is still at its infancy, and there is a great potential in sophisticated electromechanical systems to perform complex surgical tasks when these systems evolve. 2. To date, in the vast majority of clinical settings, there is little or no advantage in using robotic systems in general surgery in terms of clinical outcome. Dedicated parameters should be addressed, and high quality research should focus on quality of care instead of routine parameters, where a clear advantage is not to be expected. 3. Preliminary data demonstrates that robotic system have a clinical benefit in performing complex procedures in confined spaces, especially in those that are located in unfavorable anatomical locations. 4. There is a severe lack of high quality data on robotic surgery, and there is a great need for rigorously controlled, unbiased clinical trials. These trials should be urged to address the cost-effectiveness issues as well. 5. Specific areas of research should include complex hepatobiliary surgery, surgery for gastric and esophageal cancer, revisional surgery in bariatric and upper GI surgery, surgery for large adrenal masses, and rectal surgery. All these fields show some potential for a true benefit of using current robotic systems. 6. Robotic surgery requires a specific set of skills, and needs to be trained using a dedicated, structured training program that addresses the specific knowledge, safety issues and skills essential to perform this type of surgery safely and with good outcomes. It is the responsibility of the corresponding professional organizations, not the industry, to define the training and credentialing of robotic basic skills and specific procedures. 7. Due to the special economic environment in which robotic surgery is currently employed special care should be taken in the decision making process when

  12. Choosing surgery

    DEFF Research Database (Denmark)

    Thorstensson, Carina; Lohmander, L; Frobell, Richard

    2009-01-01

    -depth qualitative interviews were conducted with young (aged 18-35), physically active individuals with ACL rupture who were participating in a RCT comparing training and surgical reconstruction with training only. 22/34 were randomised to training only but crossed over to surgery. Of these, 11 were interviewed......ABSTRACT: BACKGROUND: The objective was to understand patients' views of treatment after acute anterior cruciate ligament (ACL) injury, and their reasons for deciding to request surgery despite consenting to participate in a randomised controlled trial (to 'cross-over'). METHODS: Thirty-four in...... before surgery, and 11 were interviewed at least 6 months after surgery. To provide additional information, 12 patients were interviewed before randomisation. Interviews were audio-recorded, transcribed and analysed using the Framework approach. RESULTS: Strong preference for surgery was commonplace...

  13. Real-time three-dimensional soft tissue reconstruction for laparoscopic surgery.

    Science.gov (United States)

    Kowalczuk, Jędrzej; Meyer, Avishai; Carlson, Jay; Psota, Eric T; Buettner, Shelby; Pérez, Lance C; Farritor, Shane M; Oleynikov, Dmitry

    2012-12-01

    Accurate real-time 3D models of the operating field have the potential to enable augmented reality for endoscopic surgery. A new system is proposed to create real-time 3D models of the operating field that uses a custom miniaturized stereoscopic video camera attached to a laparoscope and an image-based reconstruction algorithm implemented on a graphics processing unit (GPU). The proposed system was evaluated in a porcine model that approximates the viewing conditions of in vivo surgery. To assess the quality of the models, a synthetic view of the operating field was produced by overlaying a color image on the reconstructed 3D model, and an image rendered from the 3D model was compared with a 2D image captured from the same view. Experiments conducted with an object of known geometry demonstrate that the system produces 3D models accurate to within 1.5 mm. The ability to produce accurate real-time 3D models of the operating field is a significant advancement toward augmented reality in minimally invasive surgery. An imaging system with this capability will potentially transform surgery by helping novice and expert surgeons alike to delineate variance in internal anatomy accurately.

  14. Laparoscopic Upper Urinary System Surgery After Specialty Training: Presentation of 50 Cases

    Directory of Open Access Journals (Sweden)

    Alper Gok

    2014-03-01

    Full Text Available Aim: Results of first 50 laparoscopic upper urinary tractus surgeries which were performed in Adiyaman State Hospital during compulsory duty after specialty training are presented. Material and Method: Fifty patients who underwent laparoscopic upper urinary tractus surgeries in our clinic between February 2012 and January 2013 were retrospectively evaluated. All of the laparoscopic procedures were performed using transperitoneal method. Results: Mean age of the patients was 42,6±13,6 (17-74, and mean operation duration was 96,8±12,4 minutes (28-165. Thirty two patients were males and 18 were females. Intraoperative complications were not seen in any of the patients and operations didn%u2019t proceed to open surgeries. All patients were mobilized at first day after the operation. No patient needed opioids as painkillers at postoperative period. Decrease in hematocrit level was obseved in a patient at early postoperative period and this patient was followed conservatively with 6 units of erythrocyte suspension. Herniation from the port area was observed in a patient who had cortical cyst excision at postoperative 3rd month. No major complication was observed. Discussion: Laparoscopic surgery which is becoming more commonly used nowadays can be safely applied in state hospitals if appropriate infrastructure is provided.

  15. The Auckland Cataract Study: Assessing Preoperative Risk Stratification Systems for Phacoemulsification Surgery in a Teaching Hospital.

    Science.gov (United States)

    Kim, Bia Z; Patel, Dipika V; Sherwin, Trevor; McGhee, Charles N J

    2016-11-01

    To evaluate 2 preoperative risk stratification systems for assessing the risk of complications in phacoemulsification cataract surgery, performed by residents, fellows, and attending physicians in a public teaching hospital. Cohort study. One observer assessed the clinical data of 500 consecutive cases, prior to phacoemulsification cataract surgery performed between April and June 2015 at Greenlane Clinical Centre, Auckland, New Zealand. Preoperatively 2 risk scores were calculated for each case using the Muhtaseb and Buckinghamshire risk stratification systems. Complications, intraoperative and postoperative, and visual outcomes were analyzed in relation to these risk scores. Intraoperative complication rates increased with higher risk scores using the Muhtaseb or Buckinghamshire stratification system (P = .001 and P = .003, respectively, n = 500). The odds ratios for residents and fellows were not significantly different from attending physicians after case-mix adjustment according to risk scores (P > .05). Postoperative complication rates increased with higher Buckinghamshire risk scores but not with Muhtaseb scores (P = .014 and P = .094, respectively, n = 476). Postoperative corrected-distance visual acuity was poorer with higher risk scores (P < .001 for both, n = 476). This study confirms that the risk of intraoperative complications increases with higher preoperative risk scores. Furthermore, higher risk scores correlate with poorer postoperative visual acuity and the Buckinghamshire risk score also correlates with postoperative complications. Therefore, preoperative assessment using such risk stratification systems could assist individual informed consent, preoperative surgical planning, safe allocation of cases to trainees, and more meaningful analyses of outcomes for individual surgeons and institutions. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Global Surgery System Strengthening: It Is All About the Right Metrics.

    Science.gov (United States)

    Watters, David A; Guest, Glenn D; Tangi, Viliami; Shrime, Mark G; Meara, John G

    2018-04-01

    Progress in achieving "universal access to safe, affordable surgery, and anesthesia care when needed" is dependent on consensus not only about the key messages but also on what metrics should be used to set goals and measure progress. The Lancet Commission on Global Surgery not only achieved consensus on key messages but also recommended 6 key metrics to inform national surgical plans and monitor scale-up toward 2030. These metrics measure access to surgery, as well as its timeliness, safety, and affordability: (1) Two-hour access to the 3 Bellwether procedures (cesarean delivery, emergency laparotomy, and management of an open fracture); (2) Surgeon, Anesthetist, and Obstetrician workforce >20/100,000; (3) Surgical volume of 5000 procedures/100,000; (4) Reporting of perioperative mortality rate; and (5 and 6) Risk rates of catastrophic expenditure and impoverishment when requiring surgery. This article discusses the definition, validity, feasibility, relevance, and progress with each of these metrics. The authors share their experience of introducing the metrics in the Pacific and sub-Saharan Africa. We identify appropriate messages for each potential stakeholder-the patients, practitioners, providers (health services and hospitals), public (community), politicians, policymakers, and payers. We discuss progress toward the metrics being included in core indicator lists by the World Health Organization and the World Bank and how they have been, or may be, used to inform National Surgical Plans in low- and middle-income countries to scale-up the delivery of safe, affordable, and timely surgical and anesthesia care to all who need it.

  17. Interactive navigation-guided ophthalmic plastic surgery: navigation enabling of telescopes and their use in endoscopic lacrimal surgeries

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2016-11-01

    Full Text Available Mohammad Javed Ali,1 Swati Singh,1 Milind N Naik,1 Swathi Kaliki,2 Tarjani Vivek Dave1 1The Institute of Dacryology, 2The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India Purpose: The aims of this study were to report the preliminary experience of using telescopes, which were enabled for navigation guidance, and their utility in complex endoscopic lacrimal surgeries. Methods: Navigation enabling of the telescope was achieved by using the AxiEM™ malleable neuronavigation shunt stylet. Image-guided dacryolocalization was performed in five patients using the intraoperative image-guided StealthStation™ system in the electromagnetic mode. The “look ahead” protocol software was used to assist the surgeon in assessing the intraoperative geometric location of the endoscope and what lies ahead in real time. All patients underwent navigation-guided powered endoscopic dacryocystorhinostomy. The utility of uninterrupted navigation guidance throughout the surgery with the endoscope as the navigating tool was noted. Results: Intraoperative geometric localization of the lacrimal sac and the nasolacrimal duct could be easily deciphered. Constant orientation of the lacrimal drainage system and the peri-lacrimal anatomy was possible without the need for repeated point localizations throughout the surgery. The “look ahead” features could accurately alert the surgeon of anatomical structures that exists at 5, 10 and 15 mm in front of the endoscope. Good securing of the shunt stylet with the telescope was found to be essential for constant and accurate navigation. Conclusion: Navigation-enabled endoscopes provide the surgeon with the advantage of sustained stereotactic anatomical awareness at all times during the surgery. Keywords: telescope, endoscope, image guidance, navigation, lacrimal surgery, powered endoscopic DCR

  18. Concept design of robotic modules for needlescopic surgery.

    Science.gov (United States)

    Sen, Shin; Harada, Kanako; Hewitt, Zackary; Susilo, Ekawahyu; Kobayashi, Etsuko; Sakuma, Ichiro

    2017-08-01

    Many minimally invasive surgical procedures and assisting robotic systems have been developed to further minimize the number and size of incisions in the body surface. This paper presents a new idea combining the advantages of modular robotic surgery, single incision laparoscopic surgery and needlescopic surgery. In the proposed concept, modules carrying therapeutic or diagnostic tools are inserted in the abdominal cavity from the navel as in single incision laparoscopic surgery and assembled to 3-mm needle shafts penetrating the abdominal wall. A three degree-of-freedom robotic module measuring 16 mm in diameter and 51 mm in length was designed and prototyped. The performance of the three connected robotic modules was evaluated. A new idea of modular robotic surgery was proposed, and demonstrated by prototyping a 3-DOF robotic module. The performance of the connected robotic modules was evaluated, and the challenges and future work were summarized.

  19. PIEZOELECTRIC BONE SURGERY: A REVIEW OF THE LITERATURE AND POTENTIAL APPLICATIONS IN VETERINARY OROMAXILLOFACIAL SURGERY

    Directory of Open Access Journals (Sweden)

    Philippe eHENNET

    2015-05-01

    Full Text Available Piezoelectric bone surgery is a recent and innovative technology permitting a selective cut of mineralized tissue while sparing soft tissue. Similar to a dental scaler, a high frequency vibration, in the range of 25-35kHz, is transmitted to a metallic tip. However, the power of the piezosurgical instrument is 3 to 6 times higher than that of a dental scaler. The major advantages of this technology include high precision, a design that increases ease of curvilinear osteotomy, less trauma to soft tissue, preservation of neurological and vascular structures, reduced hemorrhage, minimal thermal damage to the bone as well as overall improvement of healing. The handpiece of the instrument is equipped with a sterile irrigation system and light-emitting diode (LED light, which improves visibility and overall safety. Piezoelectric surgery is particularly useful when performing delicate bone procedures such as periodontal or endodontic surgery. It is also indicated when performing more invasive bone surgery such as maxillectomy, mandibulectomy, and condylectomy, where preservation of neurovascular structures is important. Piezoelectric instruments are different from rotary instrumentation or oscillating saws, they require light pressure with constant motion of the tip. Training is required to master the technique.

  20. Image-guided cancer surgery using near-infrared fluorescence

    Science.gov (United States)

    Vahrmeijer, Alexander L.; Hutteman, Merlijn; van der Vorst, Joost R.; van de Velde, C.J.H.; Frangioni, John V.

    2013-01-01

    Paradigm shifts in surgery arise when surgeons are empowered to perform surgery faster, better, and/or less expensively. Optical imaging that exploits invisible near-infrared fluorescent light has the potential to improve cancer surgery outcomes while minimizing anesthesia time and lowering healthcare costs. Because of this, the last few years have witnessed an explosion of proof-of-concept clinical trials in the field. In this review, we introduce the concept of near-infrared fluorescence imaging for cancer surgery, review the clinical trial literature to date, outline the key issues pertaining to imaging system and contrast agent optimization, discuss limitations and leverage, and provide a framework for making the technology available for the routine care of cancer patients in the near future. PMID:23881033

  1. Anti-Mullerian hormone trend evaluation after laparoscopic surgery of monolateral endometrioma using a new dual wavelengths laser system (DWLS) for hemostasis.

    Science.gov (United States)

    Nappi, Luigi; Angioni, Stefano; Sorrentino, Felice; Cinnella, Gilda; Lombardi, Michela; Greco, Pantaleo

    2016-01-01

    Operative laparoscopy is the gold standard in the treatment of endometriotic ovarian cysts. Excisional surgery is the best technique to prevent recurrences and improve symptoms but it may result in ovarian reserve damage due to the removal of healthy ovarian cortex. The aim of this study was to assess the impact on ovarian reserve of the use of dual wavelengths laser system (DWLS) hemostasis after stripping technique of monolateral endometrioma, by dosing the anti-Mullerian hormone (AMH). This prospective study was conducted at the Institute of Obstetrics and Gynecology, University of Foggia, from December 2013 to January 2015. Forty-five women underwent excision of monolateral endometriotic ovarian cyst by stripping without using a bipolar coagulation and performing hemostasis with a DWLS. The AMH serum levels were estimated before the surgery (T0), 4-6 weeks (T1) and 6-9 months (T2) after surgery. Our results suggest that an appropriate surgical technique with the use of laser hemostasis does not determine a significant reduction of ovarian reserve. Laser hemostasis could prevent follicular reserve loss after ovarian endometrioma surgery.

  2. Minimally Invasive Cardiac Surgery: Transapical Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Ming Li

    2012-01-01

    Full Text Available Minimally invasive cardiac surgery is less traumatic and therefore leads to quicker recovery. With the assistance of engineering technologies on devices, imaging, and robotics, in conjunction with surgical technique, minimally invasive cardiac surgery will improve clinical outcomes and expand the cohort of patients that can be treated. We used transapical aortic valve implantation as an example to demonstrate that minimally invasive cardiac surgery can be implemented with the integration of surgical techniques and engineering technologies. Feasibility studies and long-term evaluation results prove that transapical aortic valve implantation under MRI guidance is feasible and practical. We are investigating an MRI compatible robotic surgical system to further assist the surgeon to precisely deliver aortic valve prostheses via a transapical approach. Ex vivo experimentation results indicate that a robotic system can also be employed in in vivo models.

  3. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  4. The peritoneal fibrinolytic response to conventional and laparoscopic colonic surgery

    NARCIS (Netherlands)

    Brokelman, Walter; Holmdahl, Lena; Falk, Peter; Klinkenbijl, Jean; Reijnen, Michel

    2009-01-01

    Laparoscopic surgery is considered to induce less peritoneal trauma than conventional surgery. The peritoneal plasmin system is important in the processes of peritoneal healing and adhesion formation. The present study assessed the peritoneal fibrinolytic response to laparoscopic and conventional

  5. Failed epilepsy surgery deserves a second chance.

    Science.gov (United States)

    Reed, Chrystal M; Dewar, Sandra; Fried, Itzhak; Engel, Jerome; Eliashiv, Dawn

    2017-12-01

    Resective epilepsy surgery has been shown to have up to 70-80% success rates in patients with intractable seizure disorder. Around 20-30% of patients with Engel Classification III and IV will require reevaluation for further surgery. Common reasons for first surgery failures include incomplete resection of seizure focus, incorrect identification of seizure focus and recurrence of tumor. Clinical chart review of seventeen patients from a single adult comprehensive epilepsy program who underwent reoperation from 2007 to 2014 was performed. High resolution Brain MRI, FDG-PET, Neuropsychometric testing were completed in all cases in both the original surgery and the second procedure. Postoperative outcomes were confirmed by prospective telephone follow up and verified by review of the patient's electronic medical records. Outcomes were classified according to the modified Engel classification system: Engel classes I and II are considered good outcomes. A total of seventeen patients (involving 10 females) were included in the study. The average age of patients at second surgery was 42 (range 23-64 years). Reasons for reoperation included: incomplete first resection (n=13) and recurrence of tumor (n=4). Median time between the first and second surgery was 60 months. After the second surgery, ten of the seventeen patients (58.8%) achieved seizure freedom (Engel Class I), in agreement with other published reports. Of the ten patients who were Engel Class I, seven required extension of the previous resection margins, while three had surgery for recurrence of previously partially resected tumor. We conclude that since the risk of complications from reoperation is low and the outcome, for some, is excellent, consideration of repeat surgery is justified. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Clinical applications of robotic technology in vascular and endovascular surgery.

    Science.gov (United States)

    Antoniou, George A; Riga, Celia V; Mayer, Erik K; Cheshire, Nicholas J W; Bicknell, Colin D

    2011-02-01

    Emerging robotic technologies are increasingly being used by surgical disciplines to facilitate and improve performance of minimally invasive surgery. Robot-assisted intervention has recently been introduced into the field of vascular surgery to potentially enhance laparoscopic vascular and endovascular capabilities. The objective of this study was to review the current status of clinical robotic applications in vascular surgery. A systematic literature search was performed in order to identify all published clinical studies related to robotic implementation in vascular intervention. Web-based search engines were searched using the keywords "surgical robotics," "robotic surgery," "robotics," "computer assisted surgery," and "vascular surgery" or "endovascular" for articles published between January 1990 and November 2009. An evaluation and critical overview of these studies is reported. In addition, an analysis and discussion of supporting evidence for robotic computer-enhanced telemanipulation systems in relation to their applications in laparoscopic vascular and endovascular surgery was undertaken. Seventeen articles reporting on clinical applications of robotics in laparoscopic vascular and endovascular surgery were detected. They were either case reports or retrospective patient series and prospective studies reporting laparoscopic vascular and endovascular treatments for patients using robotic technology. Minimal comparative clinical evidence to evaluate the advantages of robot-assisted vascular procedures was identified. Robot-assisted laparoscopic aortic procedures have been reported by several studies with satisfactory results. Furthermore, the use of robotic technology as a sole modality for abdominal aortic aneurysm repair and expansion of its applications to splenic and renal artery aneurysm reconstruction have been described. Robotically steerable endovascular catheter systems have potential advantages over conventional catheterization systems

  7. Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system.

    Science.gov (United States)

    Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro

    2018-05-01

    The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.

  8. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    Science.gov (United States)

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Robotic-assisted laparoscopic surgery: recent advances in urology.

    Science.gov (United States)

    Autorino, Riccardo; Zargar, Homayoun; Kaouk, Jihad H

    2014-10-01

    The aim of the present review is to summarize recent developments in the field of urologic robotic surgery. A nonsystematic literature review was performed to retrieve publications related to robotic surgery in urology and evidence-based critical analysis was conducted by focusing on the literature of the past 5 years. The use of the da Vinci Surgical System, a robotic surgical system, has been implemented for the entire spectrum of extirpative and reconstructive laparoscopic kidney procedures. The robotic approach can be applied for a range of adrenal indications as well as for ureteral diseases, including benign and malignant conditions affecting the proximal, mid, and distal ureter. Current evidence suggests that robotic prostatectomy is associated with less blood loss compared with the open surgery. Besides prostate cancer, robotics has been used for simple prostatectomy in patients with symptomatic benign prostatic hyperplasia. Recent studies suggest that minimally invasive radical cystectomy provides encouraging oncologic outcomes mirroring those reported for open surgery. In recent years, the evolution of robotic surgery has enabled urologic surgeons to perform urinary diversions intracorporeally. Robotic vasectomy reversal and several other robotic andrological applications are being explored. In summary, robotic-assisted surgery is an emerging and safe technology for most urologic operations. The acceptance of robotic prostatectomy during the past decade has paved the way for urologists to explore the entire spectrum of extirpative and reconstructive urologic procedures. Cost remains a significant issue that could be solved by wider dissemination of the technology. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Exposure of Surgeons to Magnetic Fields during Laparoscopic and Robotic Gynecologic Surgeries.

    Science.gov (United States)

    Park, Jee Soo; Chung, Jai Won; Choi, Soo Beom; Kim, Deok Won; Kim, Young Tae; Kim, Sang Wun; Nam, Eun Ji; Cho, Hee Young

    2015-01-01

    To measure and compare levels of extremely-low-frequency magnetic field (ELF-MF) exposure to surgeons during laparoscopic and robotic gynecologic surgeries. Prospective case-control study. Canadian Task Force I. Gynecologic surgeries at the Yonsei University Health System in Seoul, Korea from July to October in 2014. Ten laparoscopic gynecologic surgeries and 10 robotic gynecologic surgeries. The intensity of ELF-MF exposure to surgeons was measured every 4 seconds during 10 laparoscopic gynecologic surgeries and 10 robotic gynecologic surgeries using portable ELF-MF measuring devices with logging capability. The mean ELF-MF exposures were .1 ± .1 mG for laparoscopic gynecologic surgeries and .3 ± .1 mG for robotic gynecologic surgeries. ELF-MF exposure levels to surgeons during robotic gynecologic surgery were significantly higher than those during laparoscopic gynecologic surgery (p gynecologic surgery and conventional laparoscopic surgery, hoping to alleviate concerns regarding the hazards of MF exposure posed to surgeons and hospital staff. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  11. Telemedicine and robotics: paving the way to the globalization of surgery.

    Science.gov (United States)

    Senapati, S; Advincula, A P

    2005-12-01

    The concept of delivering health services at a distance, or telemedicine is becoming an emerging tool for the field of surgery. For the surgical services, telepresence surgery through robotics is gradually being incorporated into health care practices. This article will provide a brief overview of the principles surrounding telemedicine and telepresence surgery as they specifically relate to robotics. Where limitations have been reached in laparoscopy, robotics has allowed further steps forward. The development of robotics in medicine has been a progression from passive to immersive technology. In gynecology, the utilization of robotics has evolved from the use of Aesop, a robotic arm for camera manipulation, to full robotic systems such as Zeus, and the daVinci surgical system. These systems have not only been used directly for a variety of procedures but have also become a useful tool for conferencing and the mentoring of surgeons from afar. As this mode of technology becomes assimilated into the culture of surgery and medicine globally, caution must be taken to carefully navigate the economic, legal and ethical implications of telemedicine. Despite the challenges faced, telepresence surgery holds promise for more widespread applications.

  12. Sentinel lymph node detection in canine oncological patients

    International Nuclear Information System (INIS)

    Balogh, L.; Andocs, G.; Mathe, D.

    2002-01-01

    Sentinel lymph node detection was investigated in dogs with spontaneously occurring tumours. In this pilot study, 24 client-owned spontaneously tumorous dogs presented for sentinel lymph node detection. A multiple method was used with a nuclear medicine technique (injection of 99mT c human serum albumin colloid) with scintigraphy and intraoperative guidance, and blue dye injection. Of the 35 lymph nodes histologically demonstrated to contain metastases, 34 (97%) were found by radioguided surgery, which means that one would have been missed in the intraoperative localisation process; 31 nodes (89%) were clearly visualised in the gamma camera images; only 27 (77%) were blue-stained by vital dye; a mere 8 lymph nodes (23%) were enlarged and therefore easily detectable by palpation. Data obtained from the harmless application of the sentinel node concept are useful for the radiopharmaceutist. The sentinel lymph node concept is well applicable in the veterinary clinic. (author)

  13. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  14. Financial impact of hand surgery programs on academic medical centers.

    Science.gov (United States)

    Hasan, Jafar S; Chung, Kevin C; Storey, Amy F; Bolg, Mary L; Taheri, Paul A

    2007-02-01

    This study analyzes the financial performance of hand surgery in the Department of Surgery at the University of Michigan. This analysis can serve as a reference for other medical centers in the financial evaluation of a hand surgery program. Fiscal year 2004 billing records for all patients (n = 671) who underwent hand surgery procedures were examined. The financial data were separated into professional revenues and costs (relating to the hand surgery program in the Section of Plastic Surgery) and into facility revenues and costs (relating to the overall University of Michigan Health System). Professional net revenue was calculated by applying historical collection rates to procedural and clinic charges. Facility revenue was calculated by applying historical collection rates to the following charge categories: inpatient/operating room, clinic facility, neurology/electromyography, radiology facilities, and occupational therapy. Total professional costs were calculated by adding direct costs and allocated overhead costs. Facility costs were obtained from the hospital's cost accounting system. Professional and facility incomes were calculated by subtracting costs from revenues. The net professional revenue and total costs were 1,069,836 and 1,027,421 dollars, respectively. Professional operating income was 42,415 dollars, or 3.96 percent of net professional revenue. Net facility revenue and total costs were 5,500,606 and 4,592,534 dollars, respectively. Facility operating income was 908,071 dollars, or 16.51 percent of net facility revenues. While contributing to the academic mission of the institution, hand surgery is financially rewarding for the Department of Surgery. In addition, hand surgery activity contributes substantially to the financial well-being of the academic medical center.

  15. Computer-assisted oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Hassfeld, S.; Brief, J.; Muehling, J.; Krempien, R.; Mende, U.; Raczkowsky, J.; Muenchenberg, J.; Woern, H.; Giess, H.; Meinzer, H.P.

    2000-01-01

    Background: Methods from the area of virtual reality are used in oral and maxillofacial surgery for the planning and three-dimensional individual simulation of surgeries. Simulation: In order to simulate complex surgeries with the aid of a computer, the diagnostic image data and especially various imaging modalities (CT, MRT, US) must be arranged in relation to each other, thus enabling rapid switching between the various modalities as well as the viewing of mixed images. Segmenting techniques for the reconstruction of three-dimensional representations of soft-tissue and osseous areas are required. We must develop ergonomic and intuitively useable interaction methods for the surgeon, thus allowing for precise and fast entry of the planned surgical intervention in the planning and simulation phase. Surgery: During the surgical phase, instrument navigation tools offer the surgeon interactive support through operation guidance and control of potential dangers. This feature is already available today. Future intraoperative assistance will take the form of such passive tools for the support of intraoperative orientation as well as so-called tracking systems (semi-active systems) which accompany and support the surgeons' work. The final form are robots which execute specific steps completely autonomously. Discussion: The techniques of virtual reality keep gaining in importance for medical applications. Many applications are still being developed or are still in the form of a prototype. However, it is already clear that developments in this area will have a considerable effect on the surgeon's routine work. (orig.) [de

  16. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  17. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  18. Grid-enabled SEE++, A Grid-Based Medical Decision Support System for Eye Muscle Surgery Conference

    CERN Document Server

    Schreiner, W.; Buchberger, M.; Kaltofen, T.

    2006-01-01

    JKU/RISC currently develops in cooperation with Upper Austrian Research (UAR) the SEE-GRID software system. SEE-GRID is based on the SEE++ software for the biomechanical 3D simulation of the human eye and its muscles. SEE++ simulates the common eye muscle surgery techniques in a graphic interactive way that is familiar to an experienced surgeon. SEE++ is world-wide the most advanced software for this purpose; it is used by various hospitals and medical doctors for surgery training and planning, SEE++ deals with the support of diagnosis and treatment of strabismus, which is the common name given to usually persistent or regularly occuring misalignment of the eyes. Strabismus is a visual defect in which eyes point in different directions. A person suffering from it may see double images due to misaligned eyes. SEE++ is able to simulate the result of the Hess-Lancaster test, from which the pathological reason of strabismus can be estimated. The outcome of such an examination is two gaze patterns of blue points a...

  19. The systemic inflammome of severe obesity before and after bariatric surgery.

    Directory of Open Access Journals (Sweden)

    Ebymar Arismendi

    Full Text Available Obesity is associated with low-grade systemic inflammation. The "inflammome" is a network layout of the inflammatory pattern. The systemic inflammome of obesity has not been described as yet. We hypothesized that it can be significantly worsened by smoking and other comorbidities frequently associated with obesity, and ameliorated by bariatric surgery (BS. Besides, whether or not these changes are mirrored in the lungs is unknown, but obesity is often associated with pulmonary inflammation and bronchial hyperresponsiveness.We sought to: (1 describe the systemic inflammome of morbid obesity; (2 investigate the effects of sex, smoking, sleep apnea syndrome, metabolic syndrome and BS upon this systemic inflammome; and, (3 determine their interplay with pulmonary inflammation.We studied 129 morbidly obese patients (96 females; age 46 ± 12 years; body mass index [BMI], 46 ± 6 kg/m2 before and one year after BS, and 20 healthy, never-smokers, (43 ± 7 years, with normal BMI and spirometry.Before BS, compared with controls, all obese subjects displayed a strong and coordinated (inflammome systemic inflammatory response (adiponectin, C-reactive protein, interleukin (IL-8, IL-10, leptin, soluble tumor necrosis factor-receptor 1(sTNF-R1, and 8-isoprostane. This inflammome was not modified by sex, smoking, or coexistence of obstructive sleep apnea and/or metabolic syndrome. By contrast, it was significantly ameliorated, albeit not completely abolished, after BS. Finally, obese subjects had evidence of pulmonary inflammation (exhaled condensate that also decreased after BS.The systemic inflammome of morbid obesity is independent of sex, smoking status and/or comorbidities, it is significantly reduced by BS and mirrored in the lungs.

  20. Application of image guidance in pituitary surgery

    Science.gov (United States)

    de Lara, Danielle; Filho, Leo F. S. Ditzel; Prevedello, Daniel M.; Otto, Bradley A.; Carrau, Ricardo L.

    2012-01-01

    Background: Surgical treatment of pituitary pathologies has evolved along the years, adding safety and decreasing morbidity related to the procedure. Advances in the field of radiology, coupled with stereotactic technology and computer modeling, have culminated in the contemporary and widespread use of image guidance systems, as we know them today. Image guidance navigation has become a frequently used technology that provides continuous three-dimensional information for the accurate performance of neurosurgical procedures. We present a discussion about the application of image guidance in pituitary surgeries. Methods: Major indications for image guidance neuronavigation application in pituitary surgery are presented and demonstrated with illustrative cases. Limitations of this technology are also presented. Results: Patients presenting a history of previous transsphenoidal surgeries, anatomical variances of the sphenoid sinus, tumors with a close relation to the internal carotid arteries, and extrasellar tumors are the most important indications for image guidance in pituitary surgeries. The high cost of the equipment, increased time of surgery due to setup time, and registration and the need of specific training for the operating room personnel could be pointed as limitations of this technology. Conclusion: Intraoperative image guidance systems provide real-time images, increasing surgical accuracy and enabling safe, minimally invasive interventions. However, the use of intraoperative navigation is not a replacement for surgical experience and a systematic knowledge of regional anatomy. It must be recognized as a tool by which the neurosurgeon can reduce the risk associated with surgical approach and treatment of pituitary pathologies. PMID:22826819

  1. Enhanced Recovery After Surgery Protocols in Major Urologic Surgery

    Directory of Open Access Journals (Sweden)

    Natalija Vukovic

    2018-04-01

    Full Text Available The purpose of the reviewThe analysis of the components of enhanced recovery after surgery (ERAS protocols in urologic surgery.Recent findingsERAS protocols has been studied for over 20 years in different surgical procedures, mostly in colorectal surgery. The concept of improving patient care and reducing postoperative complications was also applied to major urologic surgery and especially procedure of radical cystectomy. This procedure is technically challenging, due to a major surgical resection and high postoperative complication rate that may reach 65%. Several clinical pathways were introduced to improve perioperative course and reduce the length of hospital stay. These protocols differ from ERAS modalities in other surgeries. The reasons for this are longer operative time, increased risk of perioperative transfusion and infection, and urinary diversion achieved using transposed intestinal segments. Previous studies in this area analyzed the need for mechanical bowel preparation, postoperative nasogastric tube decompression, as well as the duration of urinary drainage. Furthermore, the attention has also been drawn to perioperative fluid optimization, pain management, and bowel function.SummaryNotwithstanding partial resemblance between the pathways in major urologic surgery and other pelvic surgeries, there are still scarce guidelines for ERAS protocols in urology, which is why further studies should assess the importance of preoperative medical optimization, implementation of thoracic epidural anesthesia and analgesia, and perioperative nutritional management.

  2. Applications of piezoelectric surgery in endodontic surgery: a literature review.

    Science.gov (United States)

    Abella, Francesc; de Ribot, Joan; Doria, Guillermo; Duran-Sindreu, Fernando; Roig, Miguel

    2014-03-01

    Piezosurgery (piezoelectric bone surgery) devices were developed to cut bone atraumatically using ultrasonic vibrations and to provide an alternative to the mechanical and electrical instruments used in conventional oral surgery. Indications for piezosurgery are increasing in oral and maxillofacial surgery, as in other disciplines, such as endodontic surgery. Key features of piezosurgery instruments include their ability to selectively cut bone without damaging adjacent soft tissue, to provide a clear operative field, and to cut without generating heat. Although piezosurgery instruments can be used at most stages of endodontic surgery (osteotomy, root-end resection, and root-end preparation), no published data are available on the effect of piezosurgery on the outcomes of endodontic surgery. To our knowledge, no study has evaluated the effect of piezosurgery on root-end resection, and only 1 has investigated root-end morphology after retrograde cavity preparation using piezosurgery. We conducted a search of the PubMed and Cochrane databases using appropriate terms and keywords related to the use and applications of piezoelectric surgery in endodontic surgery. A hand search also was conducted of issues published in the preceding 2 years of several journals. Two independent reviewers obtained and analyzed the full texts of the selected articles. A total of 121 articles published between January 2000 and December 2013 were identified. This review summarizes the operating principles of piezoelectric devices and outlines the applications of piezosurgery in endodontic surgery using clinical examples. Piezosurgery is a promising technical modality with applications in several aspects of endodontic surgery, but further studies are necessary to determine the influence of piezosurgery on root-end resection and root-end preparation. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Surgical packages for laparoscopic surgery

    Directory of Open Access Journals (Sweden)

    Bhattacharya K

    2005-01-01

    Full Text Available ′Packages′ are in fashion today for most surgical procedures in various corporate hospitals and this has included laparoscopic procedures too. A package system enables the hospitals to get cost settlements done more easily. Also, it is more convenient for the patients who are aware upfront of the charges. The principal disadvantages seems to be for the surgeon, who may face displeasure of the patient, hospital or insurance agencies apart from forfeiting his personal charges if (a he is a novice in laparoscopic surgery and takes extra time to complete a procedure, (b unforeseen problems occur during surgery, or (c new pathologies are discovered on exploration.

  4. Organizational Factors and Long-Term Mortality after Hip Fracture Surgery. A Cohort Study of 6143 Consecutive Patients Undergoing Hip Fracture Surgery

    DEFF Research Database (Denmark)

    Lund, Caterina A; Møller, Ann M; Wetterslev, Jørn

    2014-01-01

    OBJECTIVE: In hospital and health care organizational factors may be changed to reduce postoperative mortality. The aim of this study is to evaluate a possible association between mortality and 'length of hospital stay', 'priority of surgery', 'time of surgery', or 'surgical delay' in hip fracture...... surgery. DESIGN: Observational cohort study. SETTING: Prospectively and consecutively reported data from the Danish Anaesthesia Database were linked to The Danish National Registry of Patients and The Civil Registration System. Records on vital status, admittance, discharges, codes of diagnosis......; therefore cluster randomized clinical trials comparing different clinical set ups may be warranted evaluating health care organizational factors....

  5. Effect of bariatric surgery-induced weight loss on renal and systemic inflammation and blood pressure: a 12-month prospective study.

    Science.gov (United States)

    Fenske, Wiebke K; Dubb, Sukhpreet; Bueter, Marco; Seyfried, Florian; Patel, Karishma; Tam, Frederick W K; Frankel, Andrew H; le Roux, Carel W

    2013-01-01

    Bariatric surgery improves arterial hypertension and renal function; however, the underlying mechanisms and effect of different surgical procedures are unknown. In the present prospective study, we compared the 12-month follow-up results after Roux-en-Y gastric bypass, laparoscopic adjustable gastric banding, and laparoscopic sleeve gastrectomy on weight loss, hypertension, renal function, and inflammatory status. A total of 34 morbidly obese patients were investigated before, one and 12 months after Roux-en-Y gastric bypass (n = 10), laparoscopic adjustable gastric banding (n = 13), and laparoscopic sleeve gastrectomy (n = 11) for hypertension, kidney function, urinary and serum cytokine levels of macrophage migration inhibitory factor, monocyte chemotactic protein-1, and chemokine ligand-18. At 12 months after surgery, the patients in all 3 treatment arms showed a significant decrease in the mean body mass index, mean arterial pressure, and urinary and serum inflammatory markers (all P .8 mg/L) had a marked improvement in renal function 12 months after surgery (P < .05). Surgically induced weight loss is associated with a marked decrease in renal and systemic inflammation and arterial hypertension and improvement in renal function in patients with pre-existing renal impairment. These effects appear to be independent of surgical procedure. The improvement in renal inflammation could be 1 of the mechanisms contributing to the beneficial effects of bariatric surgery on arterial blood pressure, proteinuria, and renal function. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  6. [Introduction of computerized anesthesia-recording systems and construction of comprehensive medical information network for patients undergoing surgery in the University of Tokyo Hospital].

    Science.gov (United States)

    Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu

    2009-10-01

    The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.

  7. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    Science.gov (United States)

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  8. Patient Safety in Spine Surgery: Regarding the Wrong-Site Surgery

    OpenAIRE

    Lee, Seung-Hwan; Kim, Ji-Sup; Jeong, Yoo-Chul; Kwak, Dae-Kyung; Chun, Ja-Hae; Lee, Hwan-Mo

    2013-01-01

    Patient safety regarding wrong site surgery has been one of the priority issues in surgical fields including that of spine care. Since the wrong-side surgery in the DM foot patient was reported on a public mass media in 1996, the wrong-site surgery issue has attracted wide public interest as regarding patient safety. Despite the many wrong-site surgery prevention campaigns in spine care such as the operate through your initial program by the Canadian Orthopaedic Association, the sign your sit...

  9. Virtual reality training and assessment in laparoscopic rectum surgery.

    Science.gov (United States)

    Pan, Jun J; Chang, Jian; Yang, Xiaosong; Liang, Hui; Zhang, Jian J; Qureshi, Tahseen; Howell, Robert; Hickish, Tamas

    2015-06-01

    Virtual-reality (VR) based simulation techniques offer an efficient and low cost alternative to conventional surgery training. This article describes a VR training and assessment system in laparoscopic rectum surgery. To give a realistic visual performance of interaction between membrane tissue and surgery tools, a generalized cylinder based collision detection and a multi-layer mass-spring model are presented. A dynamic assessment model is also designed for hierarchy training evaluation. With this simulator, trainees can operate on the virtual rectum with both visual and haptic sensation feedback simultaneously. The system also offers surgeons instructions in real time when improper manipulation happens. The simulator has been tested and evaluated by ten subjects. This prototype system has been verified by colorectal surgeons through a pilot study. They believe the visual performance and the tactile feedback are realistic. It exhibits the potential to effectively improve the surgical skills of trainee surgeons and significantly shorten their learning curve. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Design of a haptic master interface for robotically assisted vitreo-retinal eye surgery

    NARCIS (Netherlands)

    Hendrix, R.; Rosielle, P.C.J.N.; Nijmeijer, H.

    2009-01-01

    Reduced dexterity and an unergonomic body posture are two of the shortcomings for the surgeon while performing conventional minimally invasive surgery or vitreoretinal eye surgery. With a master-µslave system these inconveniences during ophthalmic surgery can be overcome. To gain insight in the

  11. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  12. Bariatric surgery in hypothalamic obesity

    Directory of Open Access Journals (Sweden)

    Nathan eBingham

    2012-02-01

    Full Text Available Craniopharyngiomas (CP are epithelial neoplasms generally found in the area of the pituitary and hypothalamus. Despite benign histology, these tumors and/or their treatment often result in significant, debilitating disorders of endocrine, neurological, behavioral, and metabolic systems. Severe obesity is observed in a high percentage of patients with CP resulting in significant comorbidities and negatively impacting quality of life. Obesity occurs as a result of hypothalamic damage and disruption of normal homeostatic mechanisms regulating energy balance. Such pathological weight gain, termed hypothalamic obesity (HyOb, is often severe and refractory to therapy.Unfortunately, neither lifestyle intervention nor pharmacotherapy has proven truly effective in the treatment of CP-HyOb. Given the limited choices and poor results of these treatments, several groups have examined bariatric surgery as a treatment alternative for patients with CP-HyOb. While a large body of evidence exists supporting the use of bariatric surgery in the treatment of exogenous obesity and its comorbidities, its role in the treatment of HyOb has yet to be well defined. To date, the existing literature on bariatric surgery in CP-HyOb is largely limited to case reports and series with short term follow-up. Here we review the current reports on the use of bariatric surgery in the treatment of CP-HyOb. We also compare these results to those reported for other populations of HyOb, including Prader-Willi Syndrome and patients with melanocortin signaling defects. While initial reports of bariatric surgery in CP-HyOb are promising, their limited scope makes it difficult to draw any substantial conclusions as to the long term safety and efficacy of bariatric surgery in CP-HyOb. There continues to be a need for more robust, controlled, prospective trials with long term follow-up in order to better define the role of bariatric surgery in the treatment of all types of hypothalamic

  13. [Is the morbid obesity surgery profitable in times of crisis? A cost-benefit analysis of bariatric surgery].

    Science.gov (United States)

    Sánchez-Santos, Raquel; Sabench Pereferrer, Fátima; Estévez Fernandez, Sergio; del Castillo Dejardin, Daniel; Vilarrasa, Nuria; Frutos Bernal, Dolores; Ruiz de Adana, Juan Carlos; Masdevall Noguera, Carlos; Torres García, Antonio

    2013-10-01

    Morbid obesity is a serious health problem whose prevalence is increasing. Expensive co-morbidities are associated to these patients, as well as a reduction in the survival. Bariatric surgery resolves the co-morbidities (type 2 diabetes mellitus, 86.6%; cardiovascular risk, 79.0%; obstructive sleep apnea syndrome, 83.6%; hypertension, 61.7%), reduces the mortality rate (among 31-40%), and increases the morbid obese patients survival over a 10-years period. It provides significant savings for the National Health System. The obese patients consume a 20% plus of health resources and 68% plus of drugs than general population. Bariatric surgery requires an initial investment (diagnosis-related group cost: 7,468 €), but it is recovered in a cost-effectiveness ratio of 2.5 years. Significant savings are obtained from the third year. To the direct economic benefits associated with reduced health expenditures it should be added an increase in tax collection (sick leave and unemployment reduction is estimated in 18%, with a productivity increase of 57% for self-employed people). Bariatric surgery is one of the most cost-effective procedures in the healthcare system. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  14. Systemic Chemotherapy using FLOT - Regimen Combined with Cytoreductive Surgery plus HIPEC for Treatment of Peritoneal Metastasized Gastric Cancer. .

    Science.gov (United States)

    Müller, H; Hotopp, Th; Tofeili, A; Wutke, K

    2014-05-01

    The aim was to evaluate the feasibility and the effectiveness of neoadjuvant systemic chemotherapy using FLOT - protocol followed by cytoreductive surgery (CRS), hyperthermic intraperitoneal chemotherapy (HIPEC) followed by systemic chemotherapyand in patients with peritoneal carciriomatosis (PC) from gastric cancer. Twenty six (median age 53 years, range 39 - 71) were scheduled for three cycles of neoadjuvant systemic chemotherapy using bi-weekly FLOT - protocol followed by CRS + HIPEC. Thereafter 3 additional cycles of FLOT were given. During HIPEC in Colliseum technique Oxaliplatin was given in a dosage of 200 mg/m2 and Docetaxel in a dosage of 80 mg/m2. All patients underwent cytoreductive surgery plus HIPEC. Peritoneal Cancer index was > 15 in 3 cases only. Complete resection could be carried out in all cases (CC-O 18, CC-18). Postoperative complication rate was 23% with no mortality within 30 days. Anastomotic leakage rate was 3.2%. Overall survival was 19.0 months with a 2-year survival rate 38%. Regression analysis demonstrated a Peritoneal Cancer Index PCI > 12 as negative factor for survival. Neoadju- vant chemotherapy using FLOT - protocol followed by CRS + HIPEC seems to be associated with prolonged OS in patients with peritoneal carcinomatosis from gastric cancer. This treatment is not recommended for patients with extensive peritoneal involvement and PCI > 12.

  15. Attitudes, beliefs, and practices regarding electronic nicotine delivery systems in patients scheduled for elective surgery.

    Science.gov (United States)

    Kadimpati, Sandeep; Nolan, Margaret; Warner, David O

    2015-01-01

    Smokers are at increased risk of postoperative complications. Electronic nicotine delivery systems (ENDS; or electronic cigarettes) could be a useful tool to reduce harm in the perioperative period. This pilot study examined the attitudes, beliefs, and practices of smokers scheduled for elective surgery regarding ENDS. This was a cross-sectional survey of current cigarette smokers who were evaluated in a preoperative clinic before elective surgery at Mayo Clinic. Measures included demographic characteristics, smoking history, 2 indices assessing the perception of how smoking affected health risks, ENDS use history, and 3 indices assessing interest in, perceived benefits of, and barriers to using ENDS in the perioperative period. Of the 112 smokers who completed the survey, 62 (55%) had tried ENDS and 24 (21%) reported current use. The most commonly stated reason for using ENDS was to quit smoking. Approximately 2 in 3 participants would be willing to use ENDS to help them reduce or eliminate perioperative cigarette use, and similar proportions perceived health benefits of doing so. Of the factors studied, only attempted to quit within the last year was significantly associated with increased interest in the perioperative use of ENDS (P=.03). Compared with participants who had tried ENDS (n=62), those who had never tried ENDS (n=50) had a significantly increased interest in the perioperative use of ENDS. A substantial proportion of patients scheduled for elective surgery had tried ENDS and would consider using ENDS to reduce perioperative use of cigarettes. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  16. Real-time image guidance in laparoscopic liver surgery

    DEFF Research Database (Denmark)

    Kenngott, Hannes G.; Wagner, Martin; Gondan, Matthias

    2014-01-01

    Background: Laparoscopic liver surgery is particularly challenging owing to restricted access, risk of bleeding and lack of haptic feedback. Navigation systems have the potential to improve information on the exact position of intrahepatic tumors, and thus facilitate oncological resection....... This study aims to evaluate the feasibility of a commercially available augmented reality (AR) guidance system employing intraoperative robotic C-arm cone-beam computed tomography (CBCT) for laparoscopic liver surgery. Methods: A human liver-like phantom with sixteen target fiducials was used to evaluate...... the Syngo iPilot® AR system. Subsequently, the system was used for the laparoscopic resection of a hepatocellular carcinoma in segment 7 of a 50-year-old male patient. Results: In the phantom experiment the AR system showed a mean target registration error of 0.96 mm ± 0.52 mm with a maximum error of 2...

  17. A comparison of microdebrider assisted endoscopic sinus surgery and conventional endoscopic sinus surgery for nasal polypi.

    Science.gov (United States)

    Singh, Rohit; Hazarika, Produl; Nayak, Dipak Ranjan; Balakrishnan, R; Gangwar, Navneeta; Hazarika, Manali

    2013-07-01

    Nasal polyposis is often encountered in rhinology practice. Those who fail conservative management, a definitive surgery is essential to achieve sufficient ventilation and drainage of the affected sinuses by using either microdebrider or conventional instruments for functional endoscopic sinus surgery (FESS). A prospective study was conducted on 40 cases of nasal polypi in a tertiary care hospital. 20 cases were operated by conventional endoscopic instruments and 20 using the microdebrider. The study aimed at comparing the intra operative (blood loss, duration of surgery) and post operative results (crusting, scarring, discharge, symptoms, recurrence) between the two groups using Lund-Mackay scoring system and the data was statistically analysed. There was no statistically significant difference in surgical outcome for patients when either conventional endoscopic instruments or microdebrider was used. However, there was a significant symptomatic improvement in cases undergoing microdebrider FESS. Microdebrider assisted polypectomy is precise, relatively bloodless surgery though the precision depends on the surgeon's anatomical knowledge and operative skills. Study substantiates that these instruments are helpful but not a prerequisite for successful outcomes in FESS. The study re-emphasises the utility of the microdebrider to young learning FESS surgeons.

  18. 9th Asian Conference on Computer-Aided Surgery

    CERN Document Server

    2016-01-01

    This book presents the latest research advances in the theory, design, control, and application of robot systems intended for a variety of purposes such as manipulation, manufacturing, automation, surgery, locomotion, and biomechanics. Several chapters deal with fundamental kinematics in nature, including synthesis, calibration, redundancy, force control, dexterity, inverse and forward kinematics, kinematic singularities, and over-constrained systems. This book is a compilation of the extended versions of the very best papers selected from the many that were presented at the Asian Conference on Computer-Aided Surgery held September 16–18, 2013, in Tokyo, Japan (ACCAS 2013).

  19. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Oral Surgeries Facial Cosmetic Surgery Facial Injury / Trauma Surgery Obstructive Sleep Apnea (OSA) Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ...

  20. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  1. A comparison of revisional and primary bariatric surgery.

    Science.gov (United States)

    Fulton, Courtney; Sheppard, Caroline; Birch, Daniel; Karmali, Shazeer; de Gara, Christopher

    2017-06-01

    Revisional surgery is an important component of addressing weight regain and complications following primary bariatric surgery. Owing to provincial need and the complexity of this patient population, a specialized multidisciplinary revision clinic was developed. We sought to characterize patients who undergo revision surgery and compare their outcomes with primary bariatric surgery clinic data. We completed a retrospective chart review of bariatric revision clinic patients compared with primary bariatric surgery patients from December 2009 to June 2014. We reviewed the charts of 2769 primary bariatric clinic patients, 886 of whom had bariatric surgery, and 534 revision bariatric clinic patients, 83 of whom had revision surgery. Fewer revision clinic patients underwent surgery than primary clinic patients (22% v. 32%). The mean preoperative body mass index (BMI) was 44.7 ± 9.5 in revision patients compared with 45.7 ± 7.6 in primary bariatric surgery patients. Most revision patients had a prior vertical banded gastroplasty (VBG; 48%) or a laparoscopic adjustable gastric band (LAGB; 24%). Bands were removed in 36% of all LAGB patients presenting to clinic. Of the 134 procedures performed in the revision clinic, 83 were bariatric weight loss surgeries, and 51 were band removals. Revision clinic patients experienced a significant decrease in BMI (from 44.7 ± 9.5 to 33.8 ± 7.5, p bariatric revision clinic manages a wide variety of complex patients distinct from those seen in a primary clinic. Operative candidates at the revision clinic are chosen based on favourable medical, anatomic and psychosocial factors, keeping in mind the resource constraints of a public health care system.

  2. Angled telescopic surgery, an approach for laryngeal diagnosis and surgery without suspension

    Directory of Open Access Journals (Sweden)

    Plínio Ferreira Morgado

    1999-09-01

    Full Text Available CONTEXT: Many methods have been used successfully for the diagnosis and treatment of laryngeal diseases. Microscopic and, recently, telescopic surgery represent the state of the art in endoscopic laryngeal surgery but drawbacks are possible during their application. To keep the suspension apparatus adequately positioned, excessive force is sometimes placed on the upper teeth and tongue with the laryngoscope tube causing damage. Complications in relation to the pharynx, larynx and cardiovascular system have also been reported. OBJECTIVE: In order to reduce complications resulting from the manipulation or stimulation of the upper aerodigestive tract and from torque forces on the upper teeth. We present a method of larynx surgery in which laryngeal suspension is not required. DESIGN: Technical report. TECHNIQUES: We have devised a fiber-optic telescope with its 40mm distal portion deviated 60 degrees from the direction of the proximal portion. This angle was taken by measuring patients immediately before standard microlaryngeal surgery was performed. The surgical instruments have the same angle as the telescope, in order to work on the larynx. This technique provides an image that is not limited by the distal aperture of the laryngoscope and has an advantage in that magnification and illumination may be provided by changing the distance of the lesion from the tip of the instrument. we have operated on four patients with laryngeal diseases and have had no complications as a result of this approach. We feel that this technique gives us the freedom to view the lesions better and helps to minimize the drawbacks caused by laryngeal suspension.

  3. Enhanced Recovery After Surgery: The Plastic Surgery Paradigm Shift.

    Science.gov (United States)

    Bartlett, Erica L; Zavlin, Dmitry; Friedman, Jeffrey D; Abdollahi, Aariane; Rappaport, Norman H

    2017-12-14

    With a focus on providing high quality care and reducing facility based expenses there has been an evolution in perioperative care by way of enhanced recovery after surgery (ERAS). ERAS allows for a multidisciplinary and multimodal approach to perioperative care which not only expedites recovery but maximizes patient outcomes. This paradigm shift has been generally accepted by most surgical specialties, including plastic surgery. The goal of this study was to evaluate the impact of ERAS on outcomes in cosmetic plastic surgery. A prospective study consisting of phone call questionnaires was designed where patients from two senior plastic surgeons (N.H.R. and J.D.F.) were followed. The treatment group (n = 10) followed an ERAS protocol while the control group (n = 12) followed the traditional recovery after surgery which included narcotic usage. Patients were contacted on postoperative days (POD) 0 through 7+ and surveyed about a number of outcomes measures. The ERAS group demonstrated a significant reduction in postoperative pain on POD 0, 1, 2, and 3 (all P plastic surgery. The utility lies in the ability to expedite patient's recovery while still providing quality care. This study showed a reduction in postoperative complaints by avoiding narcotics without an increase in complications. Our findings signify the importance of ERAS protocols within cosmetic plastic surgery. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  4. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  5. Gastric Sleeve Surgery

    Science.gov (United States)

    ... Videos for Educators Search English Español Gastric Sleeve Surgery KidsHealth / For Teens / Gastric Sleeve Surgery What's in ... or buying healthy food ) Preparing for Gastric Sleeve Surgery Preparing for this major operation takes months of ...

  6. Recent Advances and History of Vitreous Surgery

    Directory of Open Access Journals (Sweden)

    Tatsuya Mimura

    2011-01-01

    Full Text Available There have been tremendous advances in the small-gauge pars plana vitrectomy (PPV systems. This review provides an overview of the recent advances and state of the art of vitreous surgery. The two most innovative advancements that have been developed in this area are the small-gauge cutter and the new illuminating systems. Compared to the traditional 20-gauge PPV, transconjunctival sutureless small-gauge PPV is a safe and effective strategy to treat a variety of vitreoretinal diseases. Chandelier illumination allows better visualisation of vitreous for bimanual surgery. The small-gauge PPV provides benefits in terms of less inflammation, less patient discomfort, and faster recovery of the visual acuity.

  7. [Complex surgical procedures in orthopedics and trauma surgery. A contribution to the proposal procedure for the DRG system in 2009].

    Science.gov (United States)

    Flohé, S; Nabring, J; Luetkes, P; Nast-Kolb, D; Windolf, J

    2008-10-01

    Since the DRG system was introduced in 2003/2004 the system for remuneration has been continually modified in conjunction with input from specialized medical associations. As part of this development of the payment system, the criteria for classification of a diagnosis-related group were further expanded and new functions were added. This contribution addresses the importance of the complex surgical procedures as criteria for subdivision of the DRG case-based lump sums in orthopedics and trauma surgery.

  8. Does bariatric surgery improve adipose tissue function?

    Science.gov (United States)

    Frikke-Schmidt, H.; O’Rourke, R. W.; Lumeng, C. N.; Sandoval, D. A.; Seeley, R. J.

    2017-01-01

    Summary Bariatric surgery is currently the most effective treatment for obesity. Not only do these types of surgeries produce significant weight loss but also they improve insulin sensitivity and whole body metabolic function. The aim of this review is to explore how altered physiology of adipose tissue may contribute to the potent metabolic effects of some of these procedures. This includes specific effects on various fat depots, the function of individual adipocytes and the interaction between adipose tissue and other key metabolic tissues. Besides a dramatic loss of fat mass, bariatric surgery shifts the distribution of fat from visceral to the subcutaneous compartment favoring metabolic improvement. The sensitivity towards lipolysis controlled by insulin and catecholamines is improved, adipokine secretion is altered and local adipose inflammation as well as systemic inflammatory markers decreases. Some of these changes have been shown to be weight loss independent, and novel hypothesis for these effects includes include changes in bile acid metabolism, gut microbiota and central regulation of metabolism. In conclusion bariatric surgery is capable of improving aspects of adipose tissue function and do so in some cases in ways that are not entirely explained by the potent effect of surgery. PMID:27272117

  9. How to prevent endophthalmitis in cataract surgeries?

    Directory of Open Access Journals (Sweden)

    Kelkar Aditya

    2008-01-01

    Full Text Available Postoperative endophthalmitis is a very devastating complication and every step should be taken to reduce its occurrence. Unattended air conditioning filter systems are often the culprits and regular maintenance of the filters is of paramount importance. Shedders of pathogenic organisms amongst the theater personnel should be identified by regular screening and should be promptly treated. In addition to the use of Povidone iodine 5% solution in the conjunctival sac few minutes prior to surgery, proper construction of wound, injectable intraocular lenses, use of prophylactic intracameral antibiotics or prophylactic subconjunctival antibiotic injection at the conclusion of cataract surgery, placing a patch after the surgery for at least 4 h and initiating topical antibiotics from the same day of surgery helps to lower the frequency of postoperative endophthalmitis. Intraoperative posterior capsule rupture and anterior vitrectomy are risk factors for acute endophthalmitis, and utmost care to prevent posterior capsular rent should be taken while performing cataract surgery. Also, in case of such complication, these patients should be closely monitored for early signs of endophthalmitis in the postoperative period. In the unfortunate event of endophthalmitis the diagnosis should be prompt and treatment must be initiated as early as possible.

  10. Warm-up before laparoscopic surgery is not essential.

    Science.gov (United States)

    Weston, Maree K; Stephens, Jacqueline H; Schafer, Amy; Hewett, Peter J

    2014-03-01

    Several recent studies have suggested that warming up prior to surgery may improve surgical performance. The purpose of this study was to investigate whether warming up prior to laparoscopic surgery improves surgical performance or reduces surgery duration. Between August 2011 and January 2012, a randomized controlled trial was conducted to compare two warm-up modalities to no warm-up. The study was conducted at a single site, with nine surgeons performing 72 laparoscopic cholecystectomies and 37 laparoscopic appendicectomies. Prior to surgery, surgeons were randomized to either laparoscopic trainer box warm-up, PlayStation 2 warm-up or no warm-up. The activity was performed within 30 min of surgery commencing. Patients provided informed consent for the surgery to be digitally recorded. Digital videodiscs (DVDs) were reviewed by an independent and blinded assessor. Data were collected on duration of surgery, level of training and perceived surgical difficulty. Surgical performance was graded using a validated scoring system. From the 109 operations performed, there were 75 usable DVDs. Overall, there were no statistical differences in the demographics of patients and surgeons in the three treatment groups, nor in the subset that had useable DVDs. There were no statistical differences in the duration of surgery or surgeon's perceived surgical difficulty. There was no statistical difference in surgical performance. This study suggests that warm-up prior to laparoscopic cholecystectomy or appendicectomy is not essential, acknowledging that there are several study limitations that preclude definitive conclusion. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  11. Epiretinal membrane surgery

    DEFF Research Database (Denmark)

    Hamoudi, Hassan; Correll Christensen, Ulrik; La Cour, Morten

    2017-01-01

    Purpose: To assess the impact of combined phacoemulsification-vitrectomy and sequential surgery for idiopathic epiretinal membrane (ERM) on refractive error (RE) and macular morphology. Methods: In this prospective clinical trial, we allocated phakic eyes with ERM to (1) cataract surgery and subs......Purpose: To assess the impact of combined phacoemulsification-vitrectomy and sequential surgery for idiopathic epiretinal membrane (ERM) on refractive error (RE) and macular morphology. Methods: In this prospective clinical trial, we allocated phakic eyes with ERM to (1) cataract surgery...... and achieved spherical equivalent); secondary outcomes were best-corrected visual acuity (BCVA), and incidence of cystoid macular oedema (CME) defined as >10% increment of central subfield macular thickness (CSMT). Results: Sixty-two eyes were enrolled. The mean RE showed a small myopic shift of -0.36D in all...... between the groups. Four cases (17%) in the CAT group had resolved visual complaints and improved BCVA after cataract surgery resulting in no need for PPV within the follow-up period. Conclusion: Surgery for idiopathic ERM in phakic eyes with either phaco-vitrectomy or sequential surgery are equal...

  12. Assessment of skills using a virtual reality temporal bone surgery simulator.

    Science.gov (United States)

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  13. Robotic liver surgery

    Science.gov (United States)

    Leung, Universe

    2014-01-01

    Robotic surgery is an evolving technology that has been successfully applied to a number of surgical specialties, but its use in liver surgery has so far been limited. In this review article we discuss the challenges of minimally invasive liver surgery, the pros and cons of robotics, the evolution of medical robots, and the potentials in applying this technology to liver surgery. The current data in the literature are also presented. PMID:25392840

  14. First year experience of robotic-assisted laparoscopic surgery with 153 cases in a general surgery department: indications, technique and results.

    Science.gov (United States)

    Tomulescu, V; Stănciulea, O; Bălescu, I; Vasile, S; Tudor, St; Gheorghe, C; Vasilescu, C; Popescu, I

    2009-01-01

    Robotic surgery was developed in response to the limitations and drawbacks of laparoscopic surgery. Since 1997 when the first robotic procedure was performed various papers pointed the advantages of robotic-assisted laparoscopic surgery, this technique is now a reality and it will probably become the surgery of the future. The aim of this paper is to present our preliminary experience with the three-arms "da Vinci S surgical system", to assess the feasibility of this technique in various abdominal and thoracic procedures and to point out the advantages of the robotic approach for each type of procedure. Between 18 January 2008 and 18 January 2009 153 patients (66 men and 87 women; mean age 48,02 years, range 6 to 84 years) underwent robotic-assisted surgical procedures in our institution; we performed 129 abdominal and 24 thoracic procedures, as follows: one cholecystectomy, 14 myotomies with Dor fundoplication, one gastroenteroanastomosis for unresectable antral gastric cancer, one transthoracic esophagectomy, 14 gastrectomies, one polypectomy through gastrotomy, 22 splenectomies,7 partial spleen resections, 22 thymectomy, 6 Nissen fundoplications, one Toupet fundoplication, one choledocho-duodeno-anastomosis, one drainage for pancreatic abscess, one distal pancreatectomy, one hepatic cyst fenestration, 7 hepatic resections, 29 colonic and rectal resections, 5 adrenalectomies, 12 total radical hysterectomies and pelvic lymphadenectomy, 3 hysterectomies with bilateral adnexectomy for uterine fibroma, one unilateral adnexectomy, and 2 cases of cervico-mediastinal goitre resection. 147 procedures were robotics completed , whereas 6 procedures were converted to open surgery due to the extent of the lesion. Average operating room time was 171 minutes (range 60 to 600 minutes, Median length of stay was 8,6 days (range 2 to 48 days). One system malfunctions was registered. Post-operatory complications occurred in 14 cases. There were no deaths. Our preliminary experience

  15. Risk Factors For Wound Infections After Implant Surgery | Onche ...

    African Journals Online (AJOL)

    OBJECTIVE: Post-operative wound infection (POWI) rates for implant surgery are in the range of 0.08 to 13% in spite of the many advances in surgery in the past decades. It is therefore imperative that we develop a system of predicting the occurrence of POWI as a key to effective prevention. One approach is for each ...

  16. Anaphylaxis and allergic reactions during surgery and medical procedures

    Directory of Open Access Journals (Sweden)

    Blas J Larrauri

    2017-10-01

    Full Text Available Anaphylaxis during anesthesia is an unpredictable, severe, and rare reaction. It has an incidence of 1/10 000 to 1/20 000 surgeries. In most series, the responsible drugs include neuromuscular blocking agents, latex, or antibiotics. The frequency and etiology of systemic allergic reactions in other medical procedures are largely unknown. The identification of responsible drugs of anaphylaxis is a complex task, requiring testing of all medications and substances used during surgery. We describe our experience in a retrospective study of 15 patients. Ten subjects developed anaphylaxis during surgery, two in endoscopic studies and one in a trans-vaginal ultrasound. The remaining two subjects, one in a trans-vaginal ultrasound and another during a dental procedure had a systemic allergic reaction. We studied all patients with all medications administered during the procedures, including latex and detergents and disinfectants. Three surgeries had to be suspended at induction of anesthesia, five were stopped incomplete and two were completed. Both patients that presented a reaction during endoscopy required intensive care unit admission and the rest were observed in a Hospital. The responsible drugs during surgery anaphylaxis were neuromuscular blocking agents, latex, patent blue, and ranitidine. Ortho-phthalaldehyde (OPA was identified during endoscopic studies; latex was responsible in transvaginal ultrasounds; and amoxicillin in the dental procedure. The aim of the present article is to review our experience studying allergic systemic reactions and anaphylaxis during general anesthesia and medical procedures, emphasizing the severity of these reactions and the need for causative drug identification.

  17. Impact of a national system for waitlist prioritization: the experience with NIKE and cataract surgery in Sweden.

    Science.gov (United States)

    Ng, Jonathon Q; Lundström, Mats

    2014-06-01

      To evaluate waiting times for first-eye cataract surgery in Sweden following widespread adoption of the Nationell Indikationsmodell for Kataraktextraktion (NIKE) tool for prioritizing patients for cataract surgery.   Waiting times for all first-eye cataract surgeries in Sweden in 2009-2011 were identified from the Swedish National Cataract Register. Waiting times were compared according to demographic, clinical and NIKE indication group for surgery. Multivariate logistic regression modelling was used to determine factors associated with waiting times less than the 3-month Government guarantee period.   There were 141,070 first-eye cataract surgeries in 2009 to 2011; an annual increase of around 6%. Over the study period, mean waiting times decreased across all NIKE groups. The proportion waiting NIKE groups. Surgery within 3 months of waitlisting was more likely for patients with a NIKE 1 indication classification (most need for surgery), in later years, male patients, younger patients and patients with a preoperative visual acuity in the better eye worse than 6/24.   Prioritizing patients for cataract surgery using NIKE reduces waiting times for those with the greatest need. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Pediatric heart surgery

    Science.gov (United States)

    Heart surgery - pediatric; Heart surgery for children; Acquired heart disease; Heart valve surgery - children ... There are many kinds of heart defects. Some are minor, and others are more serious. Defects can occur inside the heart or in the large blood vessels ...

  19. Surgical specialty procedures in rural surgery practices: implications for rural surgery training.

    Science.gov (United States)

    Sticca, Robert P; Mullin, Brady C; Harris, Joel D; Hosford, Clint C

    2012-12-01

    Specialty procedures constitute one eighth of rural surgery practice. Currently, general surgeons intending to practice in rural hospitals may not get adequate training for specialty procedures, which they will be expected to perform. Better definition of these procedures will help guide rural surgery training. Current Procedural Terminology codes for all surgical procedures for 81% of North Dakota and South Dakota rural surgeons were entered into the Dakota Database for Rural Surgery. Specialty procedures were analyzed and compared with the Surgical Council on Resident Education curriculum to determine whether general surgery training is adequate preparation for rural surgery practice. The Dakota Database for Rural Surgery included 46,052 procedures, of which 5,666 (12.3%) were specialty procedures. Highest volume specialty categories included vascular, obstetrics and gynecology, orthopedics, cardiothoracic, urology, and otolaryngology. Common procedures in cardiothoracic and vascular surgery are taught in general surgical residency, while common procedures in obstetrics and gynecology, orthopedics, urology, and otolaryngology are usually not taught in general surgery training. Optimal training for rural surgery practice should include experience in specialty procedures in obstetrics and gynecology, orthopedics, urology, and otolaryngology. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Diode Laser Application in Soft Tissue Oral Surgery

    Science.gov (United States)

    Azma, Ehsan; Safavi, Nassimeh

    2013-01-01

    Introduction: Diode laser with wavelengths ranging from 810 to 980 nm in a continuous or pulsed mode was used as a possible instrument for soft tissue surgery in the oral cavity. Discussion: Diode laser is one of laser systems in which photons are produced by electric current with wavelengths of 810, 940 and 980nm. The application of diode laser in soft tissue oral surgery has been evaluated from a safety point of view, for facial pigmentation and vascular lesions and in oral surgery excision; for example frenectomy, epulis fissuratum and fibroma. The advantages of laser application are that it provides relatively bloodless surgical and post surgical courses with minimal swelling and scarring. We used diode laser for excisional biopsy of pyogenic granuloma and gingival pigmentation. Conclusion: The diode laser can be used as a modality for oral soft tissue surgery PMID:25606331

  1. Real-time 3-dimensional virtual reality navigation system with open MRI for breast-conserving surgery

    International Nuclear Information System (INIS)

    Tomikawa, Morimasa; Konishi, Kozo; Ieiri, Satoshi; Hong, Jaesung; Uemura, Munenori; Hashizume, Makoto; Shiotani, Satoko; Tokunaga, Eriko; Maehara, Yoshihiko

    2011-01-01

    We report here the early experiences using a real-time three-dimensional (3D) virtual reality navigation system with open magnetic resonance imaging (MRI) for breast-conserving surgery (BCS). Two patients with a non-palpable MRI-detected breast tumor underwent BCS under the guidance of the navigation system. An initial MRI for the breast tumor using skin-affixed markers was performed immediately prior to excision. A percutaneous intramammary dye marker was applied to delineate an excision line, and the computer software '3D Slicer' generated a real-time 3D virtual reality model of the tumor and the puncture needle in the breast. Under guidance by the navigation system, marking procedures were performed without any difficulties. Fiducial registration errors were 3.00 mm for patient no.1, and 4.07 mm for patient no.2. The real-time 3D virtual reality navigation system with open MRI is feasible for safe and accurate excision of non-palpable MRI-detected breast tumors. (author)

  2. Cosmetic Surgery Training in Plastic Surgery Residency Programs

    Directory of Open Access Journals (Sweden)

    Colton H. L. McNichols, MD

    2017-09-01

    Conclusions:. There is an increase in dedicated cosmetic surgery rotations and fewer residents believe they need a fellowship to practice cosmetic surgery. However, the comfort level of performing facial aesthetic and body contouring procedures remains low particularly among independent residents.

  3. Breast Cancer Surgery

    Science.gov (United States)

    FACTS FOR LIFE Breast Cancer Surgery The goal of breast cancer surgery is to remove the whole tumor from the breast. Some lymph nodes ... might still be in the body. Types of breast cancer surgery There are two types of breast cancer ...

  4. Improving patient care in cardiac surgery using Toyota production system based methodology.

    Science.gov (United States)

    Culig, Michael H; Kunkle, Richard F; Frndak, Diane C; Grunden, Naida; Maher, Thomas D; Magovern, George J

    2011-02-01

    A new cardiac surgery program was developed in a community hospital setting using the operational excellence (OE) method, which is based on the principles of the Toyota production system. The initial results of the first 409 heart operations, performed over the 28 months between March 1, 2008, and June 30, 2010, are presented. Operational excellence methodology was taught to the cardiac surgery team. Coaching started 2 months before the opening of the program and continued for 24 months. Of the 409 cases presented, 253 were isolated coronary artery bypass graft operations. One operative death occurred. According to the database maintained by The Society of Thoracic Surgeons, the risk-adjusted operative mortality rate was 61% lower than the regional rate. Likewise, the risk-adjusted rate of major complications was 57% lower than The Society of Thoracic Surgeons regional rate. Daily solution to determine cause was attempted on 923 distinct perioperative problems by all team members. Using the cost of complications as described by Speir and coworkers, avoiding predicted complications resulted in a savings of at least $884,900 as compared with the regional average. By the systematic use of a real time, highly formatted problem-solving methodology, processes of care improved daily. Using carefully disciplined teamwork, reliable implementation of evidence-based protocols was realized by empowering the front line to make improvements. Low rates of complications were observed, and a cost savings of $3,497 per each case of isolated coronary artery bypass graft was realized. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  6. Risk model of thoracic aortic surgery in 4707 cases from a nationwide single-race population through a web-based data entry system: the first report of 30-day and 30-day operative outcome risk models for thoracic aortic surgery.

    Science.gov (United States)

    Motomura, Noboru; Miyata, Hiroaki; Tsukihara, Hiroyuki; Takamoto, Shinichi

    2008-09-30

    The objective of this study was to collect integrated data from nationwide hospitals using a web-based national database system to build up our own risk model for the outcome from thoracic aortic surgery. The Japan Adult Cardiovascular Surgery Database was used; this involved approximately 180 hospitals throughout Japan through a web-based data entry system. Variables and definitions are almost identical to the STS National Database. After data cleanup, 4707 records were analyzed from 97 hospitals (between January 1, 2000, and December 31, 2005). Mean age was 66.5 years. Preoperatively, the incidence of chronic lung disease was 11%, renal failure was 9%, and rupture or malperfusion was 10%. The incidence of the location along the aorta requiring replacement surgery (including overlapping areas) was: aortic root, 10%; ascending aorta, 47%; aortic arch, 44%; distal arch, 21%; descending aorta, 27%; and thoracoabdominal aorta, 8%. Raw 30-day and 30-day operative mortality rates were 6.7% and 8.6%, respectively. Postoperative incidence of permanent stroke was 6.1%, and renal failure requiring dialysis was 6.7%. OR for 30-day operative mortality was as follows: emergency or salvage, 3.7; creatinine >3.0 mg/dL, 3.0; and unexpected coronary artery bypass graft, 2.6. As a performance metric of the risk model, C-index of 30-day and 30-day operative mortality was 0.79 and 0.78, respectively. This is the first report of risk stratification on thoracic aortic surgery using a nationwide surgical database. Although condition of these patients undergoing thoracic aortic surgery was much more serious than other procedures, the result of this series was excellent.

  7. Follow-Up After Cardiac Surgery Should be Extended to at Least 120 Days When Benchmarking Cardiac Surgery Centers.

    Science.gov (United States)

    Hansen, Laura S; Sloth, Erik; Hjortdal, Vibeke E; Jakobsen, Carl-Johan

    2015-08-01

    Short-term (30 days) mortality frequently is used as an outcome measure after cardiac surgery, although it has been proposed that the follow-up period should be extended to 120 days to allow for more accurate benchmarking. The authors aimed to evaluate whether mortality rates 120 days after surgery were comparable to general mortality and to compare causes of death between the cohort and the general population. A multicenter descriptive cohort study using prospectively entered registry data. University hospital. The cohort was obtained from the Western Denmark Heart Registry and matched to the Danish National Hospital Register as well as the Danish Register of Causes of Death. A weighted, age-matched general population consisting of all Danish patients who died within the study period was identified through the central authority on Danish statistics. A total of 11,988 patients (>15 years) who underwent cardiac-surgery at Aarhus, Aalborg and Odense University Hospitals from April 1, 2006 to December 31, 2012 were included. Coronary artery bypass grafting, valve surgery and combinations. Mortality after cardiac surgery matches with mortality in the general population after 140 days. Mortality curves run almost parallel from this point onwards, regardless of The European system for cardiac operative risk evaluation (EuroSCORE) and intervention. The causes of death in the cohort differed statistically significantly from the background population (pbenchmarking cardiac surgery centers. Regardless of preoperative heart function, heart failure was the consistent leading cause of death. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... their surgery, orthognathic surgery is performed to correct functional problems. Jaw Surgery can have a dramatic effect on many aspects of life. Following are some of the conditions that may ... front, or side Facial injury Birth defects Receding lower jaw and ...

  9. Qualitative and quantitative outcomes of audience response systems as an educational tool in a plastic surgery residency program.

    Science.gov (United States)

    Arneja, Jugpal S; Narasimhan, Kailash; Bouwman, David; Bridge, Patrick D

    2009-12-01

    In-training evaluations in graduate medical education have typically been challenging. Although the majority of standardized examination delivery methods have become computer-based, in-training examinations generally remain pencil-paper-based, if they are performed at all. Audience response systems present a novel way to stimulate and evaluate the resident-learner. The purpose of this study was to assess the outcomes of audience response systems testing as compared with traditional testing in a plastic surgery residency program. A prospective 1-year pilot study of 10 plastic surgery residents was performed using audience response systems-delivered testing for the first half of the academic year and traditional pencil-paper testing for the second half. Examination content was based on monthly "Core Quest" curriculum conferences. Quantitative outcome measures included comparison of pretest and posttest and cumulative test scores of both formats. Qualitative outcomes from the individual participants were obtained by questionnaire. When using the audience response systems format, pretest and posttest mean scores were 67.5 and 82.5 percent, respectively; using traditional pencil-paper format, scores were 56.5 percent and 79.5 percent. A comparison of the cumulative mean audience response systems score (85.0 percent) and traditional pencil-paper score (75.0 percent) revealed statistically significantly higher scores with audience response systems (p = 0.01). Qualitative outcomes revealed increased conference enthusiasm, greater enjoyment of testing, and no user difficulties with the audience response systems technology. The audience response systems modality of in-training evaluation captures participant interest and reinforces material more effectively than traditional pencil-paper testing does. The advantages include a more interactive learning environment, stimulation of class participation, immediate feedback to residents, and immediate tabulation of results for the

  10. Minimally invasive spine surgery: Hurdles to be crossed

    Directory of Open Access Journals (Sweden)

    Mahesh Bijjawara

    2014-01-01

    Full Text Available MISS as a concept is noble and all surgeons need to address and minimize the surgical morbidity for better results. However, we need to be cautions and not fall prey into accepting that minimally invasive spine surgery can be done only when certain metal access systems are used. Minimally invasive spine surgery (MISS has come a long way since the description of endoscopic discectomy in 1997 and minimally invasive TLIF (mTLIF in 2003. Today there is credible evidence (though not level-I that MISS has comparable results to open spine surgery with the advantage of early postoperative recovery and decreased blood loss and infection rates. However, apart from decreasing the muscle trauma and decreasing the muscle dissection during multilevel open spinal instrumentation, there has been little contribution to address the other morbidity parameters like operative time , blood loss , access to decompression and atraumatic neural tissue handling with the existing MISS technologies. Since all these parameters contribute to a greater degree than posterior muscle trauma for the overall surgical morbidity, we as surgeons need to introspect before we accept the concept of minimally invasive spine surgery being reduced to surgeries performed with a few tubular retractors. A spine surgeon needs to constantly improve his skills and techniques so that he can minimize blood loss, minimize traumatic neural tissue handling and minimizing operative time without compromising on the surgical goals. These measures actually contribute far more, to decrease the morbidity than approach related muscle damage alone. Minimally invasine spine surgery , though has come a long way, needs to provide technical solutions to minimize all the morbidity parameters involved in spine surgery, before it can replace most of the open spine surgeries, as in the case of laparoscopic surgery or arthroscopic surgery.

  11. An Isolator System for minimally invasive surgery : The new design

    NARCIS (Netherlands)

    Horeman, T.; Jansen, F.W.; Dankelman, J.

    2010-01-01

    Background - The risk of obtaining a postsurgical infection depends highly on the air quality surrounding the exposed tissue, surgical instruments, and materials. Many isolators for open surgery have been invented to create a contained sterile volume around the exposed tissue. With the use of an

  12. Clonidine in patients undergoing noncardiac surgery

    DEFF Research Database (Denmark)

    Devereaux, P J; Sessler, Daniel I; Leslie, Kate

    2014-01-01

    BACKGROUND: Marked activation of the sympathetic nervous system occurs during and after noncardiac surgery. Low-dose clonidine, which blunts central sympathetic outflow, may prevent perioperative myocardial infarction and death without inducing hemodynamic instability. METHODS: We performed a bli...

  13. Minimally invasive surgery using the open magnetic resonance imaging system combined with video-assisted thoracoscopic surgery for synchronous hepatic and pulmonary metastases from colorectal cancer: report of four cases.

    Science.gov (United States)

    Sonoda, Hiromichi; Shimizu, Tomoharu; Takebayashi, Katsushi; Ohta, Hiroyuki; Murakami, Koichiro; Shiomi, Hisanori; Naka, Shigeyuki; Hanaoka, Jun; Tani, Tohru

    2015-05-01

    Simultaneous resection of hepatic and pulmonary metastases (HPM) from colorectal cancer (CRC) has been reported to be effective, but it is also considered invasive. We report the preliminary results of performing minimally invasive surgery using the open magnetic resonance (MR) imaging system to resect synchronous HPM from CRC in four patients. All four patients were referred for thoracoscopy-assisted interventional MR-guided microwave coagulation therapy (T-IVMR-MCT) combined with video-assisted thoracoscopic surgery (VATS). The median diameters of the HPM were 18.2 and 23.2 mm, respectively. The median duration of VATS and T-IVMR-MCT was 82.5 and 139 min, respectively. All patients were discharged without any major postoperative complications. One patient was still free of disease at 24 months and the others died of disease progression 13, 36, and 47 months without evidence of recurrence in the treated area. Thus, simultaneous VATS + T-IVMR-MCT appears to be an effective option as a minimally invasive treatment for synchronous HPM from CRC.

  14. Image-guided surgery and therapy: current status and future directions

    Science.gov (United States)

    Peters, Terence M.

    2001-05-01

    Image-guided surgery and therapy is assuming an increasingly important role, particularly considering the current emphasis on minimally-invasive surgical procedures. Volumetric CT and MR images have been used now for some time in conjunction with stereotactic frames, to guide many neurosurgical procedures. With the development of systems that permit surgical instruments to be tracked in space, image-guided surgery now includes the use of frame-less procedures, and the application of the technology has spread beyond neurosurgery to include orthopedic applications and therapy of various soft-tissue organs such as the breast, prostate and heart. Since tracking systems allow image- guided surgery to be undertaken without frames, a great deal of effort has been spent on image-to-image and image-to- patient registration techniques, and upon the means of combining real-time intra-operative images with images acquired pre-operatively. As image-guided surgery systems have become increasingly sophisticated, the greatest challenges to their successful adoption in the operating room of the future relate to the interface between the user and the system. To date, little effort has been expended to ensure that the human factors issues relating to the use of such equipment in the operating room have been adequately addressed. Such systems will only be employed routinely in the OR when they are designed to be intuitive, unobtrusive, and provide simple access to the source of the images.

  15. Computer aided surgery. Current status and future directions

    International Nuclear Information System (INIS)

    Sato, Yoshinobu

    2006-01-01

    This review describes topics in the title in the order of 3D model reconstruction and therapeutic planning based on images before surgery; registration of the actual images in virtual physical space of the patient who is under surgical operation, to the preoperative ones with use of 3D-position sensor, ultrasonics, endoscopy and X-diaphanoscopy; and their accuracy analysis. Images before surgery usually obtained with CT and MR are reconstructed in 3D for the purpose of therapeutic planning by segmentation of the target organ/site, surrounding organs, bones and blood vessels. Navigation system at the surgery functions to make the images obtained before and during operation to be integrated for their registration and displaying. Usually, the optical marker and camera both equipped in the endoscope, and position sensor (tracker) are used for integration in the operation coordinate system. For this, the actual pictures at liver operation are given. For accuracy analysis there is a theory of target registration error, which has been established on FDA demands. In future, development of technology concerned in this field like that of robot, bio-dynamics, biomaterials, sensor and high performance computing together with 4D document of surgery for feed-back to technology are desirable for the systematic growing of this surgical technology. (T.I.)

  16. Robotic surgery

    Science.gov (United States)

    ... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...

  17. After Surgery

    Science.gov (United States)

    ... side effects. There is usually some pain with surgery. There may also be swelling and soreness around ... the first few days, weeks, or months after surgery. Some other questions to ask are How long ...

  18. Ambulatory cleft lip surgery: A value analysis.

    Science.gov (United States)

    Arneja, Jugpal S; Mitton, Craig

    2013-01-01

    Socialized health systems face fiscal constraints due to a limited supply of resources and few reliable ways to control patient demand. Some form of prioritization must occur as to what services to offer and which programs to fund. A data-driven approach to decision making that incorporates outcomes, including safety and quality, in the setting of fiscal prudence is required. A value model championed by Michael Porter encompasses these parameters, in which value is defined as outcomes divided by cost. To assess ambulatory cleft lip surgery from a quality and safety perspective, and to assess the costs associated with ambulatory cleft lip surgery in North America. Conclusions will be drawn as to how the overall value of cleft lip surgery may be enhanced. A value analysis of published articles related to ambulatory cleft lip repair over the past 30 years was performed to determine what percentage of patients would be candidates for ambulatory cleft lip repair from a quality and safety perspective. An economic model was constructed based on costs associated with the inpatient stay related to cleft lip repair. On analysis of the published reports in the literature, a minority (28%) of patients are currently discharged in an ambulatory fashion following cleft lip repair. Further analysis suggests that 88.9% of patients would be safe candidates for same-day discharge. From an economic perspective, the mean cost per patient for the overnight admission component of ambulatory cleft surgery to the health care system in the United States was USD$2,390 and $1,800 in Canada. The present analysis reviewed germane publications over a 30-year period, ultimately suggesting that ambulatory cleft lip surgery results in preservation of quality and safety metrics for most patients. The financial model illustrates a potential cost saving through the adoption of such a practice change. For appropriately selected patients, ambulatory cleft surgery enhances overall health care value.

  19. External validation of the endometriosis fertility index (EFI) staging system for predicting non-ART pregnancy after endometriosis surgery.

    Science.gov (United States)

    Tomassetti, C; Geysenbergh, B; Meuleman, C; Timmerman, D; Fieuws, S; D'Hooghe, T

    2013-05-01

    Can the ability of the endometriosis fertility index (EFI) to predict non-assisted reproductive technology (ART) pregnancy after endometriosis surgery be confirmed by an external validation study? The significant relationship between the EFI score and the time to non-ART pregnancy observed in our study represents an external validation of this scoring system. The EFI was previously developed and tested prospectively in a single center, but up to now no external validation has been published. Our data provide validation of the EFI in an external fertility unit on a robust scientific basis, to identify couples with a good prognosis for spontaneous conception who can therefore defer ART treatment, regardless of their revised American Fertility Society (rAFS) endometriosis staging. Retrospective cohort study where the EFI was calculated based on history and detailed surgical findings, and related to pregnancy outcome in 233 women attempting non-ART conception immediately after surgery; all data used for EFI calculation and analysis of reproductive outcome had been collected prospectively as part of another study. The EFI score was calculated (score 0-10) for 233 women with all rAFS endometriosis stages (minimal-mild, n = 75; moderate-severe, n = 158) after endometriosis surgery (1 September 2006-30 September 2010) in a university hospital-based reproductive medicine unit with combined expertise in reproductive surgery and medically assisted reproduction. All participants attempted non-ART conception immediately after surgery by natural intercourse, ovulation induction with timed intercourse or intrauterine insemination (with or without ovulation induction or controlled ovarian stimulation). All analyses were performed for three different definitions of pregnancy [overall (any HCG >25 IU/l), clinical and ongoing >20 weeks]. Six groups were distinguished (EFI scores 1-3, 4, 5, 6, 7+8, 9+10), and Kaplan-Meier (K-M) estimates for cumulative pregnancy rate were calculated

  20. DEVELOPMENT OF PLASTIC SURGERY.

    Science.gov (United States)

    Pećanac, Marija Đ

    2015-01-01

    Plastic surgery is a medical specialty dealing with corrections of defects, improvements in appearance and restoration of lost function. Ancient times. The first recorded account of reconstructive plastic surgery was found in ancient Indian Sanskrit texts, which described reconstructive surgeries of the nose and ears. In ancient Greece and Rome, many medicine men performed simple plastic cosmetic surgeries to repair damaged parts of the body caused by war mutilation, punishment or humiliation. In the Middle Ages, the development of all medical braches, including plastic surgery was hindered. New age. The interest in surgical reconstruction of mutilated body parts was renewed in the XVIII century by a great number of enthusiastic and charismatic surgeons, who mastered surgical disciplines and became true artists that created new forms. Modern era. In the XX century, plastic surgery developed as a modern branch in medicine including many types of reconstructive surgery, hand, head and neck surgery, microsurgery and replantation, treatment of burns and their sequelae, and esthetic surgery. Contemporary and future plastic surgery will continue to evolve and improve with regenerative medicine and tissue engineering resulting in a lot of benefits to be gained by patients in reconstruction after body trauma, oncology amputation, and for congenital disfigurement and dysfunction.

  1. Chronic Renin-Angiotensin System (RAS) Blockade May Not Induce Hypotension During Anaesthesia for Bariatric Surgery.

    Science.gov (United States)

    Salvetti, Guido; Di Salvo, Claudio; Ceccarini, Giovanni; Abramo, Antonio; Fierabracci, Paola; Magno, Silvia; Piaggi, Paolo; Vitti, Paolo; Santini, Ferruccio

    2016-06-01

    The use of angiotensin-converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (ARB) for the treatment of hypertensive obese patients is steadily increasing. Some studies have reported that the use of these drugs was associated with an increased risk of hypotensive episodes, during general anaesthesia. The number of bariatric procedures is also increasing worldwide, but there is a lack of studies investigating the hypotensive effect of renin-angiotensin system (RAS) blockers in severely obese patients during general anaesthesia for bariatric surgery. The aim of this pilot study was to evaluate hemodynamic changes induced by general anaesthesia in obese patients chronically treated with ACE-I or ARB compared to a control group not treated with antihypertensive therapy. Fourteen obese subjects (mean body mass index (BMI) 47.5 kg/m(2)) treated with ACE-I or ARB and twelve obese (mean BMI 45.7 kg/m2) controls not treated with antihypertensive therapy underwent general anaesthesia to perform laparoscopic bariatric surgery. Systolic blood pressure, diastolic blood pressure, and heart rate were monitored continuously and registered at different time points: T0 before induction, then at 2, 5, 7, 10, 15, 20, 30, 60, 90, 120, and 150 min after induction, and the last time point taken following recovery from anaesthesia. A progressive reduction of both systolic and diastolic blood pressure values was observed without significant differences between the two groups. A similar trend of heart rate values was observed. In conclusion, our pilot study suggests that RAS blockers may be continued during the perioperative period in patients undergoing bariatric surgery, without increasing the risk of hypotensive episodes.

  2. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  3. A CT-ultrasound-coregistered augmented reality enhanced image-guided surgery system and its preliminary study on brain-shift estimation

    International Nuclear Information System (INIS)

    Huang, C H; Hsieh, C H; Lee, J D; Huang, W C; Lee, S T; Wu, C T; Sun, Y N; Wu, Y T

    2012-01-01

    With the combined view on the physical space and the medical imaging data, augmented reality (AR) visualization can provide perceptive advantages during image-guided surgery (IGS). However, the imaging data are usually captured before surgery and might be different from the up-to-date one due to natural shift of soft tissues. This study presents an AR-enhanced IGS system which is capable to correct the movement of soft tissues from the pre-operative CT images by using intra-operative ultrasound images. First, with reconstructing 2-D free-hand ultrasound images to 3-D volume data, the system applies a Mutual-Information based registration algorithm to estimate the deformation between pre-operative and intra-operative ultrasound images. The estimated deformation transform describes the movement of soft tissues and is then applied to the pre-operative CT images which provide high-resolution anatomical information. As a result, the system thus displays the fusion of the corrected CT images or the real-time 2-D ultrasound images with the patient in the physical space through a head mounted display device, providing an immersive augmented-reality environment. For the performance validation of the proposed system, a brain phantom was utilized to simulate brain-shift scenario. Experimental results reveal that when the shift of an artificial tumor is from 5mm ∼ 12mm, the correction rates can be improved from 32% ∼ 45% to 87% ∼ 95% by using the proposed system.

  4. Additional Surgery after Breast-Conserving Surgery Varies Widely

    Science.gov (United States)

    A study published in the Feb. 1, 2012, issue of JAMA found that the number of women who have one or more additional surgeries to remove suspected residual tumor tissue (re-excisions) following breast-conserving surgery (BCS) for breast cancer varies widely across surgeons and hospitals.

  5. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  6. Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery.

    Science.gov (United States)

    Karaguzel, Hande; Karalezli, Aylin; Aslan, Bekir Sitki

    2009-12-01

    Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.

  7. Anesthesia for off-pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Thomas M Hemmerling

    2013-01-01

    Full Text Available The evolution of techniques and knowledge of beating heart surgery has led anesthesia toward the development of new procedures and innovations to promote patient safety and ensure high standards of care. Off-pump coronary artery bypass (OPCAB surgery has shown to have some advantages compared to on-pump cardiac surgery, particularly the reduction of postoperative complications including systemic inflammation, myocardial injury, and cerebral injury. Minimally invasive surgery for single vessel OPCAB through a limited thoracotomy incision can offer the advantage of further reduction of complications. The anesthesiologist has to deal with different issues, including hemodynamic instability and myocardial ischemia during aorto-coronary bypass grafting. The anesthesiologist and surgeon should collaborate and plan the best perioperative strategy to provide optimal care and ensure a rapid and complete recovery. The use of high thoracic epidural analgesia and fast-track anesthesia offers particular benefits in beating heart surgery. The excellent analgesia, the ability to reduce myocardial oxygen consumption, and the good hemodynamic stability make high thoracic epidural analgesia an interesting technique. New scenarios are entering in cardiac anesthesia: ultra-fast-track anesthesia with extubation in the operating room and awake surgery tend to be less invasive, but can only be performed on selected patients.

  8. Quality management system of a university cardiac surgery department according to DIN EN ISO 9001 : 2000.

    Science.gov (United States)

    Beholz, S; Koch, C; Konertz, W

    2003-06-01

    A quality management system (QMS) will improve quality in health care units. This report describes the introduction of a QMS according to ISO 9001:2000 in a university cardiovascular surgery department. First, a thorough analysis of all processes of patient treatment and clinical research was obtained. Multiple interfaces were defined to different departments as well as to administration units. We evaluated and optimized all necessary resources, evaluating customer satisfaction using patients' and referring physicians' surveys. We started quality rounds including surgeons, nurses and technicians. Based on this preparation, we redefined and explained all processes including their responsibilities and necessary resources in the quality manual. After a process of 18 months, an independent, accredited organization recommended that our QMS be given certification according to ISO 9001:2000. Certification of a university cardiovascular surgery department according to ISO 9001:2000 is possible, and may represent the first step towards total quality management (TQM). In complex health care units, certification of separate departments may help generate a consciousness of quality on the way to TQM.

  9. Timing of surgery for hip fracture and in-hospital mortality: a retrospective population-based cohort study in the Spanish National Health System

    Directory of Open Access Journals (Sweden)

    Librero Julián

    2012-01-01

    Full Text Available Abstract Background While the benefits or otherwise of early hip fracture repair is a long-running controversy with studies showing contradictory results, this practice is being adopted as a quality indicator in several health care organizations. The aim of this study is to analyze the association between early hip fracture repair and in-hospital mortality in elderly people attending public hospitals in the Spanish National Health System and, additionally, to explore factors associated with the decision to perform early hip fracture repair. Methods A cohort of 56,500 patients of 60-years-old and over, hospitalized for hip fracture during the period 2002 to 2005 in all the public hospitals in 8 Spanish regions, were followed up using administrative databases to identify the time to surgical repair and in-hospital mortality. We used a multivariate logistic regression model to analyze the relationship between the timing of surgery ( Results Early surgery was performed on 25% of the patients. In the unadjusted analysis early surgery showed an absolute difference in risk of mortality of 0.57 (from 4.42% to 3.85%. However, patients undergoing delayed surgery were older and had higher comorbidity and severity of illness. Timeliness for surgery was not found to be related to in-hospital mortality once confounding factors such as age, sex, chronic comorbidities as well as the severity of illness were controlled for in the multivariate analysis. Conclusions Older age, male gender, higher chronic comorbidity and higher severity measured by the Risk Mortality Index were associated with higher mortality, but the time to surgery was not.

  10. Nose Surgery

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  11. Error reporting from the da Vinci surgical system in robotic surgery: A Canadian multispecialty experience at a single academic centre.

    Science.gov (United States)

    Rajih, Emad; Tholomier, Côme; Cormier, Beatrice; Samouëlian, Vanessa; Warkus, Thomas; Liberman, Moishe; Widmer, Hugues; Lattouf, Jean-Baptiste; Alenizi, Abdullah M; Meskawi, Malek; Valdivieso, Roger; Hueber, Pierre-Alain; Karakewicz, Pierre I; El-Hakim, Assaad; Zorn, Kevin C

    2017-05-01

    The goal of the study is to evaluate and report on the third-generation da Vinci surgical (Si) system malfunctions. A total of 1228 robotic surgeries were performed between January 2012 and December 2015 at our academic centre. All cases were performed by using a single, dual console, four-arm, da Vinci Si robot system. The three specialties included urology, gynecology, and thoracic surgery. Studied outcomes included the robotic surgical error types, immediate consequences, and operative side effects. Error rate trend with time was also examined. Overall robotic malfunctions were documented on the da Vinci Si systems event log in 4.97% (61/1228) of the cases. The most common error was related to pressure sensors in the robotic arms indicating out of limit output. This recoverable fault was noted in 2.04% (25/1228) of cases. Other errors included unrecoverable electronic communication-related in 1.06% (13/1228) of cases, failed encoder error in 0.57% (7/1228), illuminator-related in 0.33% (4/1228), faulty switch in 0.24% (3/1228), battery-related failures in 0.24% (3/1228), and software/hardware error in 0.08% (1/1228) of cases. Surgical delay was reported only in one patient. No conversion to either open or laparoscopic occurred secondary to robotic malfunctions. In 2015, the incidence of robotic error rose to 1.71% (21/1228) from 0.81% (10/1228) in 2014. Robotic malfunction is not infrequent in the current era of robotic surgery in various surgical subspecialties, but rarely consequential. Their seldom occurrence does not seem to affect patient safety or surgical outcome.

  12. Factors affecting interest in cardiothoracic surgery: Survey of North American general surgery residents.

    Science.gov (United States)

    Vaporciyan, Ara A; Reed, Carolyn E; Erikson, Clese; Dill, Michael J; Carpenter, Andrea J; Guleserian, Kristine J; Merrill, Walter

    2009-05-01

    Applications to cardiothoracic surgery (CTS) training programs have declined precipitously. The viewpoints of potential applicants, general surgery residents, have not yet been assessed. Their perceptions are crucial to understanding the cause and formulating appropriate changes in our educational system. An initial survey instrument was content-validated, and the final instrument was distributed electronically between March 24 and May 2, 2008 through 251 general surgery program directors to all Accreditation Council for Graduate Medical Education-accredited general surgery residents (7508). The response rate was 29% (2153 residents; 89% programs). Respondent's demographics matched existing data; 6% were committed to CTS, and 26% reported prior or current interest in CTS. Interest waned after postgraduate year 3. Interest correlated with CTS rotation duration. Of the respondents committed to CTS, 76% had mentors (71% were cardiothoracic surgeons). CTS had the most shortcomings among 9 subspecialties. Job security and availability accounted for 46% of reported shortcomings (3 to 14 times higher than other subspecialties). Work schedule accounted for 25%. Length of training was not a very important factor, although it was identified as an option to increase interest in CTS. Residents who were undecided or uninterested in CTS were twice as likely to cite the ability to balance work and personal life as important than residents who chose CTS. The dominant concern documented in the survey is job security and availability. The importance of mentorship and exposure to CTS faculty in promoting interest was also evident. Decision makers should consider these findings when planning changes in education and the specialty.

  13. Laparoscopic surgery for benign and malign diseases of the digestive system: indications, limitations, and evidence.

    Science.gov (United States)

    Küper, Markus Alexander; Eisner, Friederike; Königsrainer, Alfred; Glatzle, Jörg

    2014-05-07

    The laparoscopic technique was introduced in gastrointestinal surgery in the mid 1980s. Since then, the development of this technique has been extraordinary. Triggered by technical innovations (stapling devices or coagulation/dissecting devices), nowadays any type of gastrointestinal resection has been successfully performed laparoscopically and can be performed laparoscopically dependent on the patient's condition. This summary gives an overview over 30 years of laparoscopic surgery with focus on today's indications and evidence. Main indications remain the more common procedures, e.g., appendectomy, cholecystectomy, bariatric procedures or colorectal resections. For all these indications, the laparoscopic approach has become the gold standard with less perioperative morbidity. Regarding oncological outcome there have been several high-quality randomized controlled trials which demonstrated equivalency between laparoscopic and open colorectal resections. Less common procedures like esophagectomy, oncological gastrectomy, liver and pancreatic resections can be performed successfully as well by an experienced surgeon. However, the evidence for these special indications is poor and a general recommendation cannot be given. In conclusion, laparoscopic surgery has revolutionized the field of gastrointestinal surgery by reducing perioperative morbidity without disregarding surgical principles especially in oncological surgery.

  14. Future of robotic surgery.

    Science.gov (United States)

    Lendvay, Thomas Sean; Hannaford, Blake; Satava, Richard M

    2013-01-01

    In just over a decade, robotic surgery has penetrated almost every surgical subspecialty and has even replaced some of the most commonly performed open oncologic procedures. The initial reports on patient outcomes yielded mixed results, but as more medical centers develop high-volume robotics programs, outcomes appear comparable if not improved for some applications. There are limitations to the current commercially available system, and new robotic platforms, some designed to compete in the current market and some to address niche surgical considerations, are being developed that will change the robotic landscape in the next decade. Adoption of these new systems will be dependent on overcoming barriers to true telesurgery that range from legal to logistical. As additional surgical disciplines embrace robotics and open surgery continues to be replaced by robotic approaches, it will be imperative that adequate education and training keep pace with technology. Methods to enhance surgical performance in robotics through the use of simulation and telementoring promise to accelerate learning curves and perhaps even improve surgical readiness through brief virtual-reality warm-ups and presurgical rehearsal. All these advances will need to be carefully and rigorously validated through not only patient outcomes, but also cost efficiency.

  15. Concomitant atrial fibrillation surgery for people undergoing cardiac surgery

    Science.gov (United States)

    Huffman, Mark D; Karmali, Kunal N; Berendsen, Mark A; Andrei, Adin-Cristian; Kruse, Jane; McCarthy, Patrick M; Malaisrie, S C

    2016-01-01

    Background People with atrial fibrillation (AF) often undergo cardiac surgery for other underlying reasons and are frequently offered concomitant AF surgery to reduce the frequency of short- and long-term AF and improve short- and long-term outcomes. Objectives To assess the effects of concomitant AF surgery among people with AF who are undergoing cardiac surgery on short-term and long-term (12 months or greater) health-related outcomes, health-related quality of life, and costs. Search methods Starting from the year when the first “maze” AF surgery was reported (1987), we searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library (March 2016), MEDLINE Ovid (March 2016), Embase Ovid (March 2016), Web of Science (March 2016), the Database of Abstracts of Reviews of Effects (DARE, April 2015), and Health Technology Assessment Database (HTA, March 2016). We searched trial registers in April 2016. We used no language restrictions. Selection criteria We included randomised controlled trials evaluating the effect of any concomitant AF surgery compared with no AF surgery among adults with preoperative AF, regardless of symptoms, who were undergoing cardiac surgery for another indication. Data collection and analysis Two review authors independently selected studies and extracted data. We evaluated the risk of bias using the Cochrane ‘Risk of bias’ tool. We included outcome data on all-cause and cardiovascular-specific mortality, freedom from atrial fibrillation, flutter, or tachycardia off antiarrhythmic medications, as measured by patient electrocardiographic monitoring greater than three months after the procedure, procedural safety, 30-day rehospitalisation, need for post-discharge direct current cardioversion, health-related quality of life, and direct costs. We calculated risk ratios (RR) for dichotomous data with 95% confidence intervals (CI) using a fixed-effect model when heterogeneity was low (I2 ≤ 50%) and random

  16. Robotics in Colorectal Surgery [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Allison Weaver

    2016-09-01

    Full Text Available Over the past few decades, robotic surgery has developed from a futuristic dream to a real, widely used technology. Today, robotic platforms are used for a range of procedures and have added a new facet to the development and implementation of minimally invasive surgeries. The potential advantages are enormous, but the current progress is impeded by high costs and limited technology. However, recent advances in haptic feedback systems and single-port surgical techniques demonstrate a clear role for robotics and are likely to improve surgical outcomes. Although robotic surgeries have become the gold standard for a number of procedures, the research in colorectal surgery is not definitive and more work needs to be done to prove its safety and efficacy to both surgeons and patients.

  17. Predictors of mortality within 1 year after primary ovarian cancer surgery

    DEFF Research Database (Denmark)

    Sjøland, Mette Ørskov; Iachina, Maria; Sørensen, Rikke Guldberg

    2016-01-01

    System. PARTICIPANTS: 2654 women who underwent surgery due to a diagnosis of primary ovarian cancer. OUTCOME MEASURES: Overall survival and predictors of mortality within 0-180 and 181-360 days after the primary surgery. Examined predictors were age, preoperative American Society of Anesthesiologists...

  18. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  19. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  20. 3D laparoscopic surgery: a prospective clinical trial.

    Science.gov (United States)

    Agrusa, Antonino; Di Buono, Giuseppe; Buscemi, Salvatore; Cucinella, Gaspare; Romano, Giorgio; Gulotta, Gaspare

    2018-04-03

    Since it's introduction, laparoscopic surgery represented a real revolution in clinical practice. The use of a new generation three-dimensional (3D) HD laparoscopic system can be considered a favorable "hybrid" made by combining two different elements: feasibility and diffusion of laparoscopy and improved quality of vision. In this study we report our clinical experience with use of three-dimensional (3D) HD vision system for laparoscopic surgery. Between 2013 and 2017 a prospective cohort study was conducted at the University Hospital of Palermo. We considered 163 patients underwent to laparoscopic three-dimensional (3D) HD surgery for various indications. This 3D-group was compared to a retrospective-prospective control group of patients who underwent the same surgical procedures. Considerating specific surgical procedures there is no significant difference in term of age and gender. The analysis of all the groups of diseases shows that the laparoscopic procedures performed with 3D technology have a shorter mean operative time than comparable 2D procedures when we consider surgery that require complex tasks. The use of 3D laparoscopic technology is an extraordinary innovation in clinical practice, but the instrumentation is still not widespread. Precisely for this reason the studies in literature are few and mainly limited to the evaluation of the surgical skills to the simulator. This study aims to evaluate the actual benefits of the 3D laparoscopic system integrating it in clinical practice. The three-dimensional view allows advanced performance in particular conditions, such as small and deep spaces and promotes performing complex surgical laparoscopic procedures.

  1. Image guided surgery for petrous apex lesions

    International Nuclear Information System (INIS)

    Van Havenbergh, T.; De Ridder, D.; Verlooy, J.; Koekelkoren, E.; Van De Heyning, P.

    2003-01-01

    To evaluate whether computer-assisted frameless stereotactic navigation in the temporal bone provides sufficient clinical application accuracy and thus a useful tool in temporal bone surgery. Two patients with petrous apex cholesterol granuloma were operated on by an epidural middle fossa approach using a Stealth/MedtronicTM neuronavigation system. Based an literature data optimal skin fiducial placement and registration methods were used. Intra-operative accuracy was checked using three precise anatomical landmarks. Drilling of the petrotis apex bone was guided by neuronavigation. Postoperative Computed Tomography (CT) images were fused with the preoperative CT and planning. The application of image-guidance in temporal bone surgery causes no additional burden to the patient nor prolongs the operating time. The accuracy measured at the anatomical landmarks was under 2,0 mm. This is confirmed by evaluation of bone removal through image fusion of pre- and postoperative CT scan. The clinical application of a neuronavigation system during petrous apex surgery can be regarded as useful. Using all available data on registration methods it seems possible to obtain intra-operative application accuracies of < 2,0 mm. Additional cadaver work is being performed to support these data. (author)

  2. Femtosecond laser-assisted compared with standard cataract surgery for removal of advanced cataracts.

    Science.gov (United States)

    Hatch, Kathryn M; Schultz, Tim; Talamo, Jonathan H; Dick, H Burkhard

    2015-09-01

    To compare effective phacoemulsification time (EPT) for the removal of brunescent cataracts treated with femtosecond laser-assisted cataract surgery with standard cataract phacoemulsification techniques. Ruhr University Eye Hospital, Bochum, Germany. Comparative prospective case study. The Lens Opacities Classification System III (LOCS III) grading system was used to measure eyes divided into 4 groups having cataract surgery. Groups 1 and 2 contained eyes with LOCS III grade nuclear opalescence (NO) 3 cataracts treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. Groups 3 and 4 contained brunescent cataracts, LOCS III grades NO5, treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. There were 240 eyes, with 60 eyes in each group. The EPT in Group 1 ranged from 0.46 to 3.10 (mean 1.38); the EPT in all eyes in Group 2 was 0 (P Talamo, and Dick are consultants to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  4. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  5. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  6. Benign prostatic hyperplasia: clinical treatment can complicate cataract surgery

    Directory of Open Access Journals (Sweden)

    Fernando Facio

    2010-10-01

    Full Text Available PURPOSE: To investigate the effects of alpha-1 adrenergic receptor antagonists for the treatment of benign prostatic hyperplasia (BPH regarding potential risks of complications in the setting of cataract surgery. AIM: To address recommendations, optimal control therapy, voiding symptoms and safety within the setting of cataract surgery. MATERIALS AND METHODS: A comprehensive literature review was performed using MEDLINE with MeSH terms and keywords "benign prostatic hyperplasia", "intraoperative floppy iris syndrome", "adrenergic alpha-antagonist" and "cataract surgery". In addition, reference lists from identified publications were reviewed to identify reports and studies of interest from 2001 to 2009. RESULTS: The first report of intraoperative floppy iris syndrome (IFIS was observed during cataract surgery in patients taking systemic alpha-1 AR antagonists in 2005. It has been most commonly seen related to use of tamsulosin. Changes of medication and washout periods of up to 2 weeks have been attempted to reduce the risk of complications in the setting of cataract surgery. CONCLUSION: Patients under clinical treatment for BPH should be informed about potential risks of this drug class so that it can be discuss with their healthcare providers, in particular urologist and ophthalmologist, prior to cataract surgery.

  7. Developing effective automated feedback in temporal bone surgery simulation.

    Science.gov (United States)

    Wijewickrema, Sudanthi; Piromchai, Patorn; Zhou, Yun; Ioannou, Ioanna; Bailey, James; Kennedy, Gregor; O'Leary, Stephen

    2015-06-01

    We aim to test the effectiveness, accuracy, and usefulness of an automated feedback system in facilitating skill acquisition in virtual reality surgery. We evaluate the performance of the feedback system through a randomized controlled trial of 24 students allocated to feedback and nonfeedback groups. The feedback system was based on the Melbourne University temporal bone surgery simulator. The study was conducted at the simulation laboratory of the Royal Victorian Eye and Ear Hospital, Melbourne. The study participants were medical students from the University of Melbourne, who were asked to perform virtual cortical mastoidectomy on the simulator. The extent to which the drilling behavior of the feedback and nonfeedback groups differed was used to evaluate the effectiveness of the system. Its accuracy was determined through a postexperiment observational assessment of recordings made during the experiment by an expert surgeon. Its usability was evaluated using students' self-reports of their impressions of the system. A Friedman's test showed that there was a significant improvement in the drilling performance of the feedback group, χ(2)(1) = 14.450, P feedback (when trainee behavior was detected) 88.6% of the time and appropriate feedback (accurate advice) 84.2% of the time. Participants' opinions about the usefulness of the system were highly positive. The automated feedback system was observed to be effective in improving surgical technique, and the provided feedback was found to be accurate and useful. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  8. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery

    Directory of Open Access Journals (Sweden)

    Wujun Geng

    2015-01-01

    Full Text Available Objective. Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Methods. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA pump, (2 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Results. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL- 6 levels at 24 and 48 h after the operation. Conclusion. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  9. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery.

    Science.gov (United States)

    Geng, Wujun; Hong, Wandong; Wang, Junlu; Dai, Qinxue; Mo, Yunchang; Shi, Kejian; Sun, Jiehao; Qin, Jinling; Li, Mei; Tang, Hongli

    2015-01-01

    Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA) pump, (2) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3) 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL-) 6 levels at 24 and 48 h after the operation. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  10. Combined surgery versus cataract surgery alone for eyes with cataract and glaucoma.

    Science.gov (United States)

    Zhang, Mingjuan Lisa; Hirunyachote, Phenpan; Jampel, Henry

    2015-07-14

    Cataract and glaucoma are leading causes of blindness worldwide, and their co-existence is common in elderly people. Glaucoma surgery can accelerate cataract progression, and performing both surgeries may increase the rate of postoperative complications and compromise the success of either surgery. However, cataract surgery may independently lower intraocular pressure (IOP), which may allow for greater IOP control among patients with co-existing cataract and glaucoma. The decision between undergoing combined glaucoma and cataract surgery versus cataract surgery alone is complex. Therefore, it is important to compare the effectiveness of these two interventions to aid clinicians and patients in choosing the better treatment approach. To assess the relative effectiveness and safety of combined surgery versus cataract surgery (phacoemulsification) alone for co-existing cataract and glaucoma. The secondary objectives include cost analyses for different surgical techniques for co-existing cataract and glaucoma. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 10), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2014), EMBASE (January 1980 to October 2014), PubMed (January 1948 to October 2014), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 3 October 2014.We checked the reference lists of the included trials to identify further relevant trials. We used the Science Citation Index to search for references to

  11. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  12. Application of robotics in general surgery: initial experience.

    Science.gov (United States)

    Nguyen, Ninh T; Hinojosa, Marcelo W; Finley, David; Stevens, Melinda; Paya, Mahbod

    2004-10-01

    Robotic surgery was recently approved for clinical use in general abdominal surgery. The aim of this study was to review our experience with the da Vinci surgical system during laparoscopic general surgical procedures. Eighteen patients underwent robotically assisted laparoscopic abdominal surgery between June 2002 and March 2003. Main outcome measures were operative time, room setup time, robotic arm-positioning and surgical time, blood loss, conversion to laparoscopy, length of stay, and morbidity. The types of robotically assisted laparoscopic procedures were excision of gastric leiomyoma (n = 1), Heller myotomy (n = 1), cholecystectomy (n = 2), gastric banding (n = 2), Nissen fundoplication (n = 4), and gastric bypass (n = 8). The mean room setup time was 63 +/- 14 minutes, and the mean robotic arm-positioning time was 16 +/- 7 minutes. Conversion to laparoscopy occurred in two (11%) of 18 cases because of equipment difficulty (n = 1) and technical difficulty (n = 1). Estimated blood loss was 91 +/- 71 mL. The mean operative time was 156 +/- 42 minutes, and the robotic operative time was 27% of the total operative time. The mean length of hospital stay was 2.2 +/- 1.5 days. There was one postoperative wound infection and one anastomotic stricture. Robotically assisted laparoscopic abdominal surgery is feasible and safe; however, the theoretical advantages of the da Vinci surgical system were not clinically apparent.

  13. Reduction Mammoplasty: A Comparison Between Operations Performed by Plastic Surgery and General Surgery.

    Science.gov (United States)

    Kordahi, Anthony M; Hoppe, Ian C; Lee, Edward S

    2015-01-01

    Reduction mammoplasty is an often-performed procedure by plastic surgeons and increasingly by general surgeons. The question has been posed in both general surgical literature and plastic surgical literature as to whether this procedure should remain the domain of surgical specialists. Some general surgeons are trained in breast reductions, whereas all plastic surgeons receive training in this procedure. The National Surgical Quality Improvement Project provides a unique opportunity to compare the 2 surgical specialties in an unbiased manner in terms of preoperative comorbidities and 30-day postoperative complications. The National Surgical Quality Improvement Project database was queried for the years 2005-2012. Patients were identified as having undergone a reduction mammoplasty by Current Procedural Terminology codes. RESULTS were refined to include only females with an International Classification of Diseases, Ninth Revision, code of 611.1 (hypertrophy of breasts). Information was collected regarding age, surgical specialty performing procedure, body mass index, and other preoperative variables. The outcomes utilized were presence of superficial surgical site infection, presence of deep surgical site infection, presence of wound dehiscence, postoperative respiratory compromise, pulmonary embolism, deep vein thrombosis, perioperative transfusion, operative time, reintubation, reoperation, and length of hospital stay. During this time period, there were 6239 reduction mammaplasties performed within the National Surgical Quality Improvement Project database: 339 by general surgery and 5900 by plastic surgery. No statistical differences were detected between the 2 groups with regard to superficial wound infections, deep wound infections, organ space infections, or wound dehiscence. There were no significant differences noted between within groups with regard to systemic postoperative complications. Patients undergoing a procedure by general surgery were more likely

  14. Simplified Model Surgery Technique for Segmental Maxillary Surgeries

    Directory of Open Access Journals (Sweden)

    Namit Nagar

    2011-01-01

    Full Text Available Model surgery is the dental cast version of cephalometric prediction of surgical results. Patients having vertical maxillary excess with prognathism invariably require Lefort I osteotomy with maxillary segmentation and maxillary first premolar extractions during surgery. Traditionally, model surgeries in these cases have been done by sawing the model through the first premolar interproximal area and removing that segment. This clinical innovation employed the use of X-ray film strips as separators in maxillary first premolar interproximal area. The method advocated is a time-saving procedure where no special clinical or laboratory tools, such as plaster saw (with accompanying plaster dust, were required and reusable separators were made from old and discarded X-ray films.

  15. Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.

    Science.gov (United States)

    Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke

    2015-12-01

    Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.

  16. Clinical Outcome of Sacral Chordoma With Carbon Ion Radiotherapy Compared With Surgery

    International Nuclear Information System (INIS)

    Nishida, Yoshihiro; Kamada, Tadashi; Imai, Reiko; Tsukushi, Satoshi; Yamada, Yoshihisa; Sugiura, Hideshi; Shido, Yoji; Wasa, Junji; Ishiguro, Naoki

    2011-01-01

    Purpose: To evaluate the efficacy, post-treatment function, toxicity, and complications of carbon ion radiotherapy (RT) for sacral chordoma compared with surgery. Methods and Materials: The records of 17 primary sacral chordoma patients treated since 1990 with surgery (n = 10) or carbon ion RT (n = 7) were retrospectively analyzed for disease-specific survival, local recurrence-free survival, complications, and functional outcome. The applied carbon ion dose ranged from 54.0 Gray equivalent (GyE) to 73.6 GyE (median 70.4). Results: The mean age at treatment was 55 years for the surgery group and 65 years for the carbon ion RT group. The median duration of follow-up was 76 months for the surgery group and 49 months for the carbon ion RT group. The local recurrence-free survival rate at 5 years was 62.5% for the surgery and 100% for the carbon ion RT group, and the disease-specific survival rate at 5 years was 85.7% and 53.3%, respectively. Urinary-anorectal function worsened in 6 patients (60%) in the surgery group, but it was unchanged in all the patients who had undergone carbon ion RT. Postoperative wound complications requiring reoperation occurred in 3 patients (30%) after surgery and in 1 patient (14%) after carbon ion RT. The functional outcome evaluated using the Musculoskeletal Tumor Society scoring system revealed 55% in the surgery group and 75% in the carbon ion RT group. Of the six factors in this scoring system, the carbon ion RT group had significantly greater scores in emotional acceptance than did the surgery group. Conclusion: Carbon ion RT results in a high local control rate and preservation of urinary-anorectal function compared with surgery.

  17. [The advantages of implementing an e-learning platform for laparoscopic liver surgery].

    Science.gov (United States)

    Furcea, L; Graur, F; Scurtu, L; Plitea, N; Pîslă, D; Vaida, C; Deteşan, O; Szilaghy, A; Neagoş, H; Mureşan, A; Vlad, L

    2011-01-01

    The rapid expansion of laparoscopic surgery has led to the development of training methods for acquiring technical skills. The importance and complexity of laparoscopic liver surgery are arguments for developing a new integrated system of teaching, learning and evaluation, based on modern educational principles, on flexibility allowing wide accessibility among surgeons. This paper presents the development of e-learning platform designed for training in laparoscopic liver surgery and pre-planning of the operation in a virtual environment. E-learning platform makes it possible to simulate laparoscopic liver surgery remotely via internet connection. The addressability of this e-learning platform is large, being represented by young surgeons who are mainly preoccupied by laparoscopic liver surgery, as well as experienced surgeons interested in obtaining a competence in the hepatic minimally invasive surgery.

  18. Femtosecond laser cataract surgery: technology and clinical practice.

    Science.gov (United States)

    Roberts, Timothy V; Lawless, Michael; Chan, Colin Ck; Jacobs, Mark; Ng, David; Bali, Shveta J; Hodge, Chris; Sutton, Gerard

    2013-03-01

    The recent introduction of femtosecond lasers to cataract surgery has generated much interest among ophthalmologists around the world. Laser cataract surgery integrates high-resolution anterior segment imaging systems with a femtosecond laser, allowing key steps of the procedure, including the primary and side-port corneal incisions, the anterior capsulotomy and fragmentation of the lens nucleus, to be performed with computer-guided laser precision. There is emerging evidence of reduced phacoemulsification time, better wound architecture and a more stable refractive result with femtosecond cataract surgery, as well as reports documenting an initial learning curve. This article will review the current state of technology and discuss our clinical experience. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  19. Step-based cognitive virtual surgery simulation: an innovative approach to surgical education.

    Science.gov (United States)

    Oliker, Aaron; Napier, Zachary; Deluccia, Nicolette; Qualter, John; Sculli, Frank; Smith, Brandon; Stern, Carrie; Flores, Roberto; Hazen, Alexes; McCarthy, Joseph

    2012-01-01

    BioDigital Systems, LLC in collaboration with New York University Langone Medical Center Department of Reconstructive Plastic Surgery has created a complex, real-time, step-based simulation platform for plastic surgery education. These simulators combine live surgical footage, interactive 3D visualization, text labels, and voiceover as well as a high-yield, expert-approved testing mode to create a comprehensive virtual educational environment for the plastic surgery resident or physician.

  20. Robotic surgery, video-assisted thoracic surgery, and open surgery for early stage lung cancer: comparison of costs and outcomes at a single institute.

    Science.gov (United States)

    Novellis, Pierluigi; Bottoni, Edoardo; Voulaz, Emanuele; Cariboni, Umberto; Testori, Alberto; Bertolaccini, Luca; Giordano, Laura; Dieci, Elisa; Granato, Lorenzo; Vanni, Elena; Montorsi, Marco; Alloisio, Marco; Veronesi, Giulia

    2018-02-01

    Robotic surgery is increasingly used to resect lung cancer. However costs are high. We compared costs and outcomes for robotic surgery, video-assisted thoracic surgery (VATS), and open surgery, to treat non-small cell lung cancer (NSCLC). We retrospectively assessed 103 consecutive patients given lobectomy or segmentectomy for clinical stage I or II NSCLC. Three surgeons could choose VATS or open, the fourth could choose between all three techniques. Between-group differences were assessed by Fisher's exact, two-way analysis of variance (ANOVA), and Wilcoxon-Mann-Whitney test. P values open surgery. Age, physical status, pulmonary function, comorbidities, stage, and perioperative complications did not differ between the groups. Pathological tumor size was greater in the open than VATS and robotic groups (P=0.025). Duration of surgery was 150, 191 and 116 minutes, by robotic, VATS and open approaches, respectively (Popen groups. Estimated costs were 82%, 68% and 69%, respectively, of the regional health service reimbursement for robotic, VATS and open approaches. Robotic surgery for early lung cancer was associated with shorter stay and more extensive lymph node dissection than VATS and open surgery. Duration of surgery was shorter for robotic than VATS. Although the cost of robotic thoracic surgery is high, the hospital makes a profit.

  1. Nerve-Highlighting Fluorescent Contrast Agents for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Summer L. Gibbs-Strauss

    2011-03-01

    Full Text Available Nerve damage is the major morbidity of many surgeries, resulting in chronic pain, loss of function, or both. The sparing of nerves during surgical procedures is a vexing problem because surrounding tissue often obscures them. To date, systemically administered nerve-highlighting contrast agents that can be used for nerve-sparing image-guided surgery have not been reported. In the current study, physicochemical and optical properties of 4,4‘-[(2-methoxy-1,4-phenylenedi-(1E-2,1-ethenediyl]bis-benzenamine (BMB and a newly synthesized, red-shifted derivative 4-[(1E-2-[4-[(1E-2-[4-aminophenyl]ethenyl]-3-methoxyphenyl]ethenyl]-benzonitrile (GE3082 were characterized in vitro and in vivo. Both agents crossed the blood-nerve barrier and blood-brain barrier and rendered myelinated nerves fluorescent after a single systemic injection. Although both BMB and GE3082 also exhibited significant uptake in white adipose tissue, GE3082 underwent a hypsochromic shift in adipose tissue that provided a means to eliminate the unwanted signal using hyperspectral deconvolution. Dose and kinetic studies were performed in mice to determine the optimal dose and drug-imaging interval. The results were confirmed in rat and pig, with the latter used to demonstrate, for the first time, simultaneous fluorescence imaging of blood vessels and nerves during surgery using the FLARE™ (Fluorescence-Assisted Resection and Exploration imaging system. These results lay the foundation for the development of ideal nerve-highlighting fluorophores for image-guided surgery.

  2. Hallux valgus surgery affects kinematic parameters during gait.

    Science.gov (United States)

    Klugarova, Jitka; Janura, Miroslav; Svoboda, Zdenek; Sos, Zdenek; Stergiou, Nicholas; Klugar, Miloslav

    2016-12-01

    The aim of our study was to compare spatiotemporal parameters and lower limb and pelvis kinematics during the walking in patients with hallux valgus before and after surgery and in relation to a control group. Seventeen females with hallux valgus, who underwent first metatarsal osteotomy, constituted our experimental group. The control group consisted of thirteen females. Kinematic data during walking were obtained using the Vicon MX system. Our results showed that hallux valgus before surgery affects spatiotemporal parameters and lower limb and pelvis kinematics during walking. Hallux valgus surgery further increased the differences that were present before surgery. Specifically after hallux valgus surgery, the walking speed decreased even more (p=0.09, η 2 =0.19) while step time increased (p=0.002, η 2 =0.44) on both legs. The maximum ankle plantar flexion of the operated leg during toe-off decreased to a greater extend (p=0.03, η 2 =0.26). The asymmetry in the hip and the pelvis movements in the frontal plane (present preoperatively) persisted after surgery. Hallux valgus is not an isolated problem of the first ray, which could be just surgically addressed by correcting the foot's alignment. It is a long-term progressive malfunction of the foot affecting the entire kinematic chain of the lower extremity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Large Intracranial Aneurysm after Transsphenoidal Surgery for Pituitary Macroadenoma

    OpenAIRE

    Yoon, Kyeong-Wook; Cho, Chun-Sung; Lee, Sang-Koo

    2014-01-01

    Uncontrolled cerebrospinal fluid (CSF) leakage after transsphenoidal surgery (TSS) for pituitary adenoma can lead to meningitis. Intracranial mycotic pseudoaneurysm is a rare complication in central nervous system infection. Large single pseudoaneurysm is more uncommon. Most mycotic aneurysms occur due to endocarditis. The present patient had no heart problem and was infected by CSF leakage after transsphenoidal surgery. We present a case of large ruptured mycotic pseudoaneurysm as a complica...

  4. Solo surgeon single-port laparoscopic surgery with a homemade laparoscope-anchored instrument system in benign gynecologic diseases.

    Science.gov (United States)

    Yang, Yun Seok; Kim, Seung Hyun; Jin, Chan Hee; Oh, Kwoan Young; Hur, Myung Haeng; Kim, Soo Young; Yim, Hyun Soon

    2014-01-01

    The objective of this study was to present the initial operative experience of solo surgeon single-port laparoscopic surgery (SPLS) in the laparoscopic treatment of benign gynecologic diseases and to investigate its feasibility and surgical outcomes. Using a novel homemade laparoscope-anchored instrument system that consisted of a laparoscopic instrument attached to a laparoscope and a glove-wound retractor umbilical port, we performed solo surgeon SPLS in 13 patients between March 2011 and June 2012. Intraoperative complications and postoperative surgical outcomes were determined. The primary operative procedures performed were unilateral salpingo-oophorectomy (n = 5), unilateral salpingectomy (n = 2), adhesiolysis (n = 1), and laparoscopically assisted vaginal hysterectomy (n = 5). Additional surgical procedures included additional adhesiolysis (n = 4) and ovarian drilling (n = 1).The primary indications for surgery were benign ovarian tumors (n = 5), ectopic pregnancy (n = 2), pelvic adhesion (infertility) (n = 1), and benign uterine tumors (n = 5). Solo surgeon SPLS was successfully accomplished in all procedures without a laparoscopic assistant. There were no intraoperative or postoperative complications. Our laparoscope-anchored instrument system obviates the need for an additional laparoscopic assistant and enables SPLS to be performed by a solo surgeon. The findings show that with our system, solo surgeon SPLS is a feasible and safe alternative technique for the treatment of benign gynecologic diseases in properly selected patients. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  5. SURGERY AND CARDIOVASCULAR SURGERY JOURNALS ANALYSIS.

    Science.gov (United States)

    Schanaider, Alberto

    2015-01-01

    To analyze critically the effectiveness and value of bibliometric indicators in journals of Surgery or Cardiovacular Surgery in the context of the postgraduate programs of CAPES Medicine III. A sampling with 16 academic programs and one professional master of Medicine III, encompassing the General and Digestive System Surgery, Cardiovascular Surgery and Multidisciplinary courses with such contents, was evaluated. Thomson Reuters/ISI (JCR), Elsevier/Scopus (SJR), and also Scielo databases were used. Only in seven programs, the teachers had an average of Qualis A1 articles greater than the others strata. Eleven journals in the surgical area are in stratum A1 (5%) and it reaches 25% in Cardiovascular Surgery. Among the six journals with the largest number of publications Qualis A1 in area Medicine III, five are from non-specific areas. The Acta Cirúrgica Brasileira represented 58% of the publications in the stratum A2. There are some obstacles in the Qualis classification with little uniformity among the Medicine areas I, II and III. A permanent committee should be set to update the Qualis, composed by the three medical areas. It should be considered using other index databases and the unification of the Qualis criteria for journals in medicine. Rating criteria of multi and transdisciplinary journals need to be reviewed. It is essential an institutional financial support for national journals chosen by peers aiming to provide a full computerization process and a professional reviewer of the English language, in order to increase the impact factor. Analisar criticamente a eficácia e valor de indicadores bibliométricos dos periódicos da Cirurgia e Cirurgia Cardiovascular no contexto dos Programas de Pós-Graduação da área Medicina III da CAPES. Foi avaliada uma amostragem com 16 programas acadêmicos e um mestrado profissional da área de Medicina III, compreendendo a Cirurgia Geral e do Aparelho Digestivo, a Cirurgia Cardiovascular e Cursos Multidisciplinares

  6. Ontology-based prediction of surgical events in laparoscopic surgery

    Science.gov (United States)

    Katić, Darko; Wekerle, Anna-Laura; Gärtner, Fabian; Kenngott, Hannes; Müller-Stich, Beat Peter; Dillmann, Rüdiger; Speidel, Stefanie

    2013-03-01

    Context-aware technologies have great potential to help surgeons during laparoscopic interventions. Their underlying idea is to create systems which can adapt their assistance functions automatically to the situation in the OR, thus relieving surgeons from the burden of managing computer assisted surgery devices manually. To this purpose, a certain kind of understanding of the current situation in the OR is essential. Beyond that, anticipatory knowledge of incoming events is beneficial, e.g. for early warnings of imminent risk situations. To achieve the goal of predicting surgical events based on previously observed ones, we developed a language to describe surgeries and surgical events using Description Logics and integrated it with methods from computational linguistics. Using n-Grams to compute probabilities of followup events, we are able to make sensible predictions of upcoming events in real-time. The system was evaluated on professionally recorded and labeled surgeries and showed an average prediction rate of 80%.

  7. Advanced laparoscopic bariatric surgery Is safe in general surgery training.

    Science.gov (United States)

    Kuckelman, John; Bingham, Jason; Barron, Morgan; Lallemand, Michael; Martin, Matthew; Sohn, Vance

    2017-05-01

    Bariatric surgery makes up an increasing percentage of general surgery training. The safety of resident involvement in these complex cases has been questioned. We evaluated patient outcomes in resident performed laparoscopic bariatric procedures. Retrospective review of patients undergoing a laparoscopic bariatric procedure over seven years at a tertiary care single center. Procedures were primarily performed by a general surgery resident and proctored by an attending surgeon. Primary outcomes included operative volume, operative time and leak rate with perioperative outcomes evaluated as secondary outcomes. A total of 1649 bariatric procedures were evaluated. Operations included laparoscopic bypass (690) and laparoscopic sleeve gastrectomy (959). Average operating time was 136 min. Eighteen leaks (0.67%) were identified. Graduating residents performed an average of 89 laparoscopic bariatric cases during their training. There were no significant differences between resident levels with concern to operative time or leak rate (p 0.97 and p = 0.54). General surgery residents can safely perform laparoscopic bariatric surgery. When proctored by a staff surgeon, a resident's level of training does not significantly impact leak rate. Published by Elsevier Inc.

  8. Metabolic Surgery in Korea: What to Consider before Surgery

    Directory of Open Access Journals (Sweden)

    Mi-Kyung Kim

    2017-09-01

    Full Text Available Obesity is increasing globally and represents a significant global health problem because it predisposes towards various diseases, such as type 2 diabetes mellitus, cardiovascular disease, degenerative joint disease, and certain types of cancer. Numerous studies have shown that bariatric surgery reduces body mass and ameliorates obesity-related complications, such as hypertension and hyperglycemia, suggesting that surgery is the most effective therapeutic option for severely obese and obese diabetic patients. Recent international guidelines recommend surgical treatment for diabetic patients with class III obesity (body mass index [BMI] >40 kg/m2, regardless of their level of glycemic control or the complexity of their glucose-lowering regimens, and for patients with class II obesity (BMI 35.0 to 39.9 kg/m2 and hyperglycemia that is poorly controlled despite appropriate lifestyle and pharmacological therapy. The most popular procedures are Roux-en-Y gastric bypass and sleeve gastrectomy, but new procedures with better outcomes have been reported. For optimal surgical outcome, comprehensive management including assessments of a medical condition, nutrition, mental health, and social support is needed before and after surgery. However, there is still a lack of understanding regarding metabolic surgery in Korea. Therefore, this article reviews indications for metabolic surgery in patients with a specific focus on the situation in Korea.

  9. Journey to top performance: a multipronged quality improvement approach to reducing cardiac surgery mortality.

    Science.gov (United States)

    Scheinerman, S Jacob; Dlugacz, Yosef D; Hartman, Alan R; Moravick, Donna; Nelson, Karen L; Scanlon, Kerri Anne; Stier, Lori

    2015-02-01

    In 2006, leadership at Long Island Jewish Medical Center (New Hyde Park, New York) noted significantly higher cardiac surgery mortality rates for isolated valve and valve/coronary artery bypass graft procedures compared to the New York State Department of Health's Cardiac Surgery Reporting System statewide average. Long Island Jewish Medical Center, a 583-bed nonprofit, tertiary care teaching hospital, is one of the clinical and academic hubs of North Shore-LIJ Health System. Senior leadership launched an evaluation of the cardiac surgery program to determine why cardiac surgery mortality rates were higher than expected. As a result, the cardiac surgery program was redesigned, and interventions were implemented related to preoperative care, intraoperative monitoring, postoperative care, and the cardiac surgery quality management program. According to the most recent New York State Department of Health reporting period (2009-2011), Long Island Jewish Medical Center had the lowest risk-adjusted mortality rate in New York State for adult patients undergoing surgeries to repair or replace heart valves and for adult patients in need of valve/coronary artery bypass graft surgery. The medical center has sustained significantly lower mortality rates compared to the statewide average for the past three cardiac surgery reporting periods. Cardiac surgery mortality rates can be significantly reduced and sustained below comparative norms when the organization is committed to clinical excellence and quality and is involved in continuously assessing organizational performance. The evaluation launched at Long Island Jewish Medical Center led to the redesign of the cardiac surgery program and prompted widespread improvement efforts and cultural change across the entire organization.

  10. Current status of cardiovascular surgery in Japan, 2013 and 2014: A report based on the Japan Cardiovascular Surgery Database (JCVSD). 1: Mission and history of JCVSD.

    Science.gov (United States)

    Takamoto, Shinichi; Motomura, Noboru; Miyata, Hiroaki; Tsukihara, Hiroyuki

    2018-01-01

    The Japan Cardiovascular Surgery Database (JCVSD) was created in 2000 with the support of the Society of Thoracic Surgeons (STS). The STS database content was translated to Japanese using the same disease criteria and in 2001, data entry for adult cardiac surgeries was initiated online using the University Hospital Medical Information Network (UMIN). In 2008, data entry for congenital heart surgeries was initiated in the congenital section of JCVSD and preoperative expected mortality (JapanSCORE) in adult cardiovascular surgeries was first calculated using the risk model of JCVSD. The Japan Surgical Board system merged with JCVSD in 2011, and all cardiovascular surgical data were registered in the JCVSD from 2012 onward. The reports resulting from the data analyses of the JCVSD will encourage further improvements in the quality of cardiovascular surgeries, patient safety, and medical care in Japan.

  11. The economic impact of revision otologic surgery.

    Science.gov (United States)

    Nadimi, Sahar; Leonetti, John P; Pontikis, George

    2016-03-01

    Revision otologic surgery places a significant economic burden on patients and the healthcare system. We conducted a retrospective chart analysis to estimate the economic impact of revision canal-wall-down (CWD) mastoidectomy. We reviewed the medical records of all 189 adults who had undergone CWD mastoidectomy performed by the senior author between June 2006 and August 2011 at Loyola University Medical Center in Maywood, Ill. Institutional charges and collections for all patients were extrapolated to estimate the overall healthcare cost of revision surgery in Illinois and at the national level. Of the 189 CWD mastoidectomies, 89 were primary and 100 were revision procedures. The total charge for the revision cases was $2,783,700, and the net reimbursement (collections) was $846,289 (30.4%). Using Illinois Hospital Association data, we estimated that reimbursement for 387 revision CWD mastoidectomies that had been performed in fiscal year 2011 was nearly $3.3 million. By extrapolating our data to the national level, we estimated that 9,214 patients underwent revision CWD mastoidectomy in the United States during 2011, which cost the national healthcare system roughly $76 million, not including lost wages and productivity. Known causes of failed CWD mastoidectomies that often result in revision surgery include an inadequate meatoplasty, a facial ridge that is too high, residual diseased air cells, and recurrent cholesteatoma. A better understanding of these factors can reduce the need for revision surgery, which could have a positive impact on the economic strain related to this procedure at the local, state, and national levels.

  12. Cataract surgery among Medicare beneficiaries.

    Science.gov (United States)

    Schein, Oliver D; Cassard, Sandra D; Tielsch, James M; Gower, Emily W

    2012-10-01

    To present descriptive epidemiology of cataract surgery among Medicare recipients in the United States. Cataract surgery performed on Medicare beneficiaries in 2003 and 2004. Medicare claims data were used to identify all cataract surgery claims for procedures performed in the United States in 2003-2004. Standard assumptions were used to limit the claims to actual cataract surgery procedures performed. Summary statistics were created to determine the number of procedures performed for each outcome of interest: cataract surgery rates by age, sex, race and state; surgical volume by facility type and surgeon characteristics; time interval between first- and second-eye cataract surgery. The national cataract surgery rate for 2003-2004 was 61.8 per 1000 Medicare beneficiary person-years. The rate was significantly higher for females and for those aged 75-84 years. After adjustment for age and sex, blacks had approximately a 30% lower rate of surgery than whites. While only 5% of cataract surgeons performed more than 500 cataract surgeries annually, these surgeons performed 26% of the total cataract surgeries. Increasing surgical volume was found to be highly correlated with use of ambulatory surgical centers and reduced time interval between first- and second-eye surgery in the same patient. The epidemiology of cataract surgery in the United States Medicare population documents substantial variation in surgical rates by race, sex, age, and by certain provider characteristics.

  13. Realignment Surgery for Malunited Ankle Fracture.

    Science.gov (United States)

    Guo, Chang-Jun; Li, Xing-Cheng; Hu, Mu; Xu, Yang; Xu, Xiang-Yang

    2017-02-01

    To investigate the characteristics and the results of realignment surgery for the treatment of malunited ankle fracture. Thirty-three patients with malunited fractures of the ankle who underwent reconstructive surgery at our hospital from January 2010 to January 2014 were reviewed. The tibial anterior surface angle (TAS), the tibiotalar tilt angle (TTA), the malleolar angle (MA), and the tibial lateral surface angle (TLS) were measured. Clinical assessment was performed with use of the American Orthopaedic Foot and Ankle Society (AOFAS) scale and visual analogue scale (VAS) scores, and the osteoarthritis stage was determined radiographically with the modified Takakura classification system. The Wilcoxon matched-pairs test was used to analyze the difference between the preoperative and the postoperative data. The mean follow-up was 36 months (range, 20-60 months). The mean age at the time of realignment surgery was 37.1 years (range, 18-62 years). Compared with preoperation, the TAS at the last follow-up showed a significant increase (88.50° ± 4.47° vs. 90.80° ± 3.49°, P = 0.0035); similar results were observed in TTA (1.62° ± 1.66° vs. 0.83° ± 0.90°, P ankle osteoarthritis, and was treated by ankle joint distraction. Realignment surgery for a malunited ankle fracture can reduce pain, improve function, and delay ankle arthrodesis or total ankle replacement. Postoperative large talar tilt and advanced stages of ankle arthritis are the risk factors for the surgery. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  14. Fast-track surgery: Toward comprehensive peri-operative care.

    Science.gov (United States)

    Nanavati, Aditya J; Prabhakar, S

    2014-01-01

    Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.

  15. Using your shoulder after surgery

    Science.gov (United States)

    Shoulder surgery - using your shoulder; Shoulder surgery - after ... rotator cuff surgery or other ligament or labral surgery, you need to be careful with your shoulder. Ask the surgeon what arm movements are safe ...

  16. Elective surgery cancelation on day of surgery: An endless dilemma

    Directory of Open Access Journals (Sweden)

    A Fayed

    2016-01-01

    Full Text Available Background: Cancelation of surgery is a constant agonizing dilemma for nearly all healthcare services that has been intensively investigated to find out its roots, consequences, and possible solutions. The rates of cancelation of surgery vary between centers and more so among surgical specialties with numerous reasons standing behind this phenomenon. Patients and Methods: In the current study, analysis of monthly cancelation rates from January 2009 to December 2012, and assessment of establishing new operating rooms (ORs using statistical process control charts was conducted. A detailed review of a total of 1813 cases canceled on the day of surgery from January to December 2012, to examine the various reasons of cancelation among surgical specialties. Results: The average cancelation rate was 11.1%, which dropped to 9.0% after launching of new theaters. Four reasons explained about 80% of cancelations; Patients "no show" was the leading cause of cancelation (27%. One-fourth of cancelations (24.3% were due to the need for further optimization, and the third most prominent cause of cancelation was a lack of OR time (19.5%. Unavailability of staff/equipment/implants accounted for only 0.7% of cancelations. The "no show" was the most common cause of cancelation among all surgical specialties ranging from 21% for plastic surgery to 32% in ophthalmic surgeries. Conclusion: It was confirmed that there is a unique profile of cancelation of surgery problem for every institute, an extension of infrastructure may not be the only solution. Control charts helped to enhance the general picture and are functional in monitoring and evaluating changes in the cancelation of surgery.

  17. Laparoendoscopic single-site surgery in gynaecology: A new frontier in minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Fader Amanda

    2011-01-01

    Full Text Available Review Objective: To review the recent developments and published literature on laparoendoscopic single-site (LESS surgery in gynaecology. Recent Findings: Minimally invasive surgery has become a standard of care for the treatment of many benign and malignant gynaecological conditions. Recent advances in conventional laparoscopy and robotic-assisted surgery have favorably impacted the entire spectrum of gynaecological surgery. With the goal of improving morbidity and cosmesis, continued efforts towards refinement of laparoscopic techniques have lead to minimization of size and number of ports required for these procedures. LESS surgery is a recently proposed surgical term used to describe various techniques that aim at performing laparoscopic surgery through a single, small-skin incision concealed within the umbilicus. In the last 5 years, there has been a surge in the developments in surgical technology and techniques for LESS surgery, which have resulted in a significant increase in utilisation of LESS across many surgical subspecialties. Recently published outcomes data demonstrate feasibility, safety and reproducibility for LESS in gynaecology. The contemporary LESS literature, extent of gynaecological procedures utilising these techniques and limitations of current technology will be reviewed in this manuscript. Conclusions: LESS surgery represents the newest frontier in minimally invasive surgery. Comparative data and prospective trials are necessary in order to determine the clinical impact of LESS in treatment of gynaecological conditions.

  18. Biological research in the evolution of cancer surgery: a personal perspective.

    Science.gov (United States)

    Fisher, Bernard

    2008-12-15

    During the 19th, and for most of the 20th century, malignant tumors were removed by mutilating radical anatomic dissection. Advances such as anesthesia, asepsis, and blood transfusion made possible increasingly more radical operations. There was no scientific rationale for the operations being performed. Surgery in the 20th century was dominated by the principles of William S. Halsted, who contended that the bloodstream was of little significance as a route of tumor cell dissemination; a tumor was autonomous of its host; and cancer was a local-regional disease that spread in an orderly fashion based on mechanical considerations. Halsted believed that both the extent and nuances of an operation influenced patient outcome and that inadequate surgical skill was responsible for the failure to cure. A new surgical era arose in 1957, when cancer surgery began to be influenced by laboratory and clinical research, with results contrary to Halstedian principles. A new hypothesis resulted in a scientific basis for cancer surgery. Clinical trials supported the thesis that operable cancer is a systemic disease and that variations in local-regional therapy are unlikely to substantially affect survival. Complex host-tumor relationships were shown to affect every aspect of cancer and, contrary to Halsted's thesis, the bloodstream is of considerable importance in tumor dissemination. Clinical trials also have shown that less radical surgery is justified. Studies have shown that improved survival can be achieved with systemic therapy after surgery. Such therapy can reduce both the incidence of distant disease and the tumor recurrence at the tumor site after minimal surgery. The use of systemic therapy in patients who have no identifiable metastatic disease is a drastic departure from previous strategies. New technological innovations resulting from engineering research have improved the quality of life of patients by eliminating the need for some surgical procedures. Because cancer

  19. How to get the best from robotic thoracic surgery.

    Science.gov (United States)

    Ricciardi, Sara; Zirafa, Carmelina Cristina; Davini, Federico; Melfi, Franca

    2018-04-01

    The application of Robotic technology in thoracic surgery has become widespread in the last decades. Thanks to its advanced features, the robotic system allows to perform a broad range of complex operations safely and in a comfortable way, with valuable advantages related to low invasiveness. Regarding lung tumours, several studies have shown the benefits of robotic surgery including lower blood loss and improved lymph node removal when compared with other minimally invasive techniques. Moreover, the robotic instruments allow to reach deep and narrow spaces permitting safe and precise removal of tumours located in remote areas, such as retrosternal and posterior mediastinal spaces with outstanding postoperative and oncological results. One controversial finding about the application of robotic system is its high capital and running costs. For this reason, a limited number of centres worldwide are able to employ this groundbreaking technology and there are limited possibilities for the trainees to acquire the necessary skills in robotic surgery. Therefore, a training programme based on three steps of learning, associated with a solid surgical background and a consistent operating activity, are required to obtain effective results. Putting this highest technological innovation in the hand of expert surgeons we can assure safe and effective procedures getting the best from robotic thoracic surgery.

  20. Iris recognition as a biometric method after cataract surgery.

    Science.gov (United States)

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.