WorldWideScience

Sample records for radioguided surgery system

  1. A γ detecting probe developed for radioguided surgery and its primary using for animal experiment

    International Nuclear Information System (INIS)

    Wei Haipeng, Lin Yingwu; Gong Peirong; Yang Zhirong; Qiu Shi

    2003-01-01

    A new γ detecting probe device was described, which was used in radioguided surgery (RGS) for detecting tumor and its micrometastasis. The concrete scheme for this system was given in this paper and its performance was also evaluate. The animal experimental results showed that the γ detecting probe has excellent location resolution, and its collimator is practical

  2. Radio-guided thoracoscopic surgery (RGTS) of small pulmonary nodules.

    Science.gov (United States)

    Ambrogi, Marcello Carlo; Melfi, Franca; Zirafa, Carmelina; Lucchi, Marco; De Liperi, Annalisa; Mariani, Giuliano; Fanucchi, Olivia; Mussi, Alfredo

    2012-04-01

    The demand for adequate tissue sampling to determine individual tumor behavior is increasing the number of lung nodule resections, even when the diagnosis is already recognized. Video-assisted thoracic surgery (VATS) is the procedure of choice for diagnosis and treatment of small pulmonary nodules. Difficulties in localizing smaller and deeper nodules have been approached with different techniques. Herein we report our 13-years' experience with radio-guided thoracoscopic resection. Patients with pulmonary nodules smaller than 1 cm and/or deeper than 1 cm, below the visceral pleura, underwent computed tomography (CT)-guided injection of a solution, composed of 0.2 ml (99)Tc-labeled human serum albumin microspheres and 0.1 ml nonionic contrast, into the nodule. During the VATS procedure, an 11-mm-diameter collimated probe connected to a gamma ray detector was introduced to scan the lung surface. The area of major radioactivity, which matched with the area of the nodule, was resected. From 1997 to 2009, 573 patients underwent thoracoscopic resection of small pulmonary nodules, 211 with the radio-guided technique. There were 159 men and 52 women, with an average age of 60.6 years (range = 12-83). The mean duration of the surgical procedure was 41 min (range = 20-100). The procedure was successful in 208/211 cases. Three patients (0.5%) required conversion to a minithoracotomy. The mean length of pleural drainage and hospital stay was 2.3 and 3.7 days, respectively. Histological examination showed 98 benign lesions and 113 malignant lesions (61 metastases and 52 primary lung cancers). This study confirms that radio-guided localization of small pulmonary nodules is a feasible, safe, and quick procedure, with a high rate of success. The spread of the sentinel lymph node technique has increased the availability of technology required for RGTS.

  3. Clinical applications of gamma-detection probes - radioguided surgery

    International Nuclear Information System (INIS)

    Schneebaum, S.; Stadler, J.; Skornick, Y.

    1999-01-01

    Radioguided surgery (RGS) is a surgical technique that enables the surgeon to identify tissue ''marked'' by a radionuclide before surgery, based on the tissue characteristics, the radioactive tracer and its carrying molecule, or the affinity of both. Thus, yet another tool has been added to the inspection and palpation traditionally used by the surgeon. Current clinical applications of radioguided surgery are: radioimmunoguided surgery (RIGS) for colon cancer, sentinel-node mapping for malignant melanoma (which has become state-of-the-art), sentinel-node mapping for breast, vulvar and penile cancer, and detection of parathyroid adenoma and bone tumour (such as osteid osteoma). Although the same gamma-detecting probe (GDP) may be used for all these applications, the carrier substance and the radionuclide differ. MoAb and peptides are used for RIGS, sulphur colloid for sentinel-node mapping, iodine-125 for RIGS, technetium-99m for sentinel node, parathyroid and bone. The mode of injection also differs, but there are some common principles of gamma-guided surgery. RIGS enables the surgeon to corroborate tumour existence, find occult metastases, and assess the margins of resection; this may result in a change on the surgical plan. Sentinel lymph-node (SLN) scintigraphy for melanoma guides the surgeon to find the involved lymph nodes for lymph-node dissection. SLN for breast cancer is being investigated with promising results. This procedure has also changed the outlook of lymph-node pathology by giving the pathologist designated tissue samples for more comprehensive examination. Gamma-guided surgery will result in more accurate and less unnecessary surgery, better pathology and, hopefully, in better patient survival. (orig.)

  4. Radioguided Surgery for Localization of Nonpalpable Breast Lesions A Mini-Review

    DEFF Research Database (Denmark)

    Langhans, Linnea; Klausen, Thomas Levin; Tvedskov, Tove Filtenborg

    2016-01-01

    by ultrasound a small titanium seed containing typically 1-10 MBq of radioactive iodine-125 is placed in the centre of the nonpalpable breast lesion. During the operation the seed is located with a hand-held gamma probe. To date, only few cohort studies exist on the feasibility of RSL, and the method has only...... of patients with insufficient resection margin. These patients require a reoperation. New methods in the field of radioguided surgery (RGS) have been developed including radioguided occult lesion localization (ROLL) and radioactive seed localization (RSL). Especially RSL is a very promising technique. Guided...

  5. Surgery with radioguided location of a liver metastasis of melanoma choroid: case report

    International Nuclear Information System (INIS)

    Moreno, Marcelo; Miranda, Mario Henrique Furlanetto

    2015-01-01

    Introduction: The use of radioguided occult lesion localization prior to surgical excision is increasing, mainly due to the development of new probes and the use of PET-CT. Case report: A 70-year-old male who presented with a metastatic lesion in his liver from a choroidal melanoma. This was located using PET-CT and subsequently located with a low-energy intraoperative gamma probe during the laparotomy. Conclusion: The present case shows that it is possible to excise a hepatic metastasis utilizing the principles of radioguided surgery, even in centers without access to high energy probes. (author)

  6. Radio-guided surgery in differentiated thyroid cancer: report of four cases

    International Nuclear Information System (INIS)

    Kallel, F.; Hamza, F.; Charfeddine, S.; Guermazi, F.; Ghorbel, A.

    2009-01-01

    Radio-guided surgery is a technique using the ability of a tumour tissue to uptake a radiopharmaceutical, in order, to facilitate its location with an intraoperative gamma probe. This technique was first used in the detection of recurrent thyroid cancer. We present our experience in this indication in four cases which were followed in our department. (authors)

  7. Sentinel lymph node detection through radioguided surgery in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita Andrade Leal de; Santos, Adriana de Morais; Soares, Livia de Almeida; Santos, Antonio Ricardo dos; Barros, Idna de Carvalho; Abreu, Everardo Leal de; Cruz Filho, Alexandre Jorge Gomes da; Abreu, Joao Batista de; Vieira, Sabas Carlos [Universidade Estadual do Piaui, Teresina, PI (Brazil); Centro Federal de Educacao Tecnologica do Piaui (CEFET-PI), Teresina, PI (Brazil); Faculdade Sao Gabriel, PI (Brazil); Hospital Sao Marcos, PI (Brazil); Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2008-12-15

    Biopsy of the sentinel lymphnode (SLNB), the first lymphnode to receive lymphatic drainage from the primary tumor, accurately predicts the axillary lymph node status and, when negative, obviates the need for axillary lymphadenectomy (AL). The aim of this study was, to verify the SLN localization in breast cancer through preoperative lymphoscintigraphy and intraoperative gamma-probe, as well as to demonstrate the benefits of such techniques in preventing complications of AL. Medical records of 228 patients with breast carcinoma, who were underwent SLN localization and, radioguided surgery, from March 2005 to December 2007 were analyzed retrospectively. Data regarding age, tumor characteristic, breast involved, type of surgery, radiopharmaceutical drainage pattern, axillary assessment (SLNB or AL) and number of lymph nodes dissected were collected. It was ascertained that radioguided surgery is a selective method of axillary assessment in breast cancer, which makes this technique a safe alternative to radical assessment of total dissection of axillary lymph nodes and its subsequent complications. (author)

  8. Sentinel lymph node detection through radioguided surgery in patients with breast cancer

    International Nuclear Information System (INIS)

    Abreu, Benedita Andrade Leal de; Santos, Adriana de Morais; Soares, Livia de Almeida; Santos, Antonio Ricardo dos; Barros, Idna de Carvalho; Abreu, Everardo Leal de; Cruz Filho, Alexandre Jorge Gomes da; Abreu, Joao Batista de; Vieira, Sabas Carlos

    2008-01-01

    Biopsy of the sentinel lymphnode (SLNB), the first lymphnode to receive lymphatic drainage from the primary tumor, accurately predicts the axillary lymph node status and, when negative, obviates the need for axillary lymphadenectomy (AL). The aim of this study was, to verify the SLN localization in breast cancer through preoperative lymphoscintigraphy and intraoperative gamma-probe, as well as to demonstrate the benefits of such techniques in preventing complications of AL. Medical records of 228 patients with breast carcinoma, who were underwent SLN localization and, radioguided surgery, from March 2005 to December 2007 were analyzed retrospectively. Data regarding age, tumor characteristic, breast involved, type of surgery, radiopharmaceutical drainage pattern, axillary assessment (SLNB or AL) and number of lymph nodes dissected were collected. It was ascertained that radioguided surgery is a selective method of axillary assessment in breast cancer, which makes this technique a safe alternative to radical assessment of total dissection of axillary lymph nodes and its subsequent complications. (author)

  9. Radioguided surgery with MIBI in brain tumors: on the subject of a case

    International Nuclear Information System (INIS)

    Martín Escuela, Juan Miguel

    2016-01-01

    Many efforts are directed towards better intraoperative detection and delimitation of brain tumors, in order to achieve better resection. A recent technique, implemented is radioguided surgery in which the tumor tissue is marked with a radiotracer (MIBI) and through the use of a probe and / or gamma camera to differentiate it from healthy brain tissue, in vivo, in the surgery room. : Evaluate the feasibility of radioguided surgery and optimize the procedures with the purpose of developing a clinical protocol for the reception of brain tumors. MATERIALS AND METHODS: A patient with a high grade glioma was submitted to MIBI, confirming that gamma camera facilitated the intraoperative detection of the tumor and indicated a small piece of residual tumor that was subsequently resected, Achieving total resection of the lesion. Conclusion: Radio-guided surgery with MIBI, showed, in this case, that it is a safe and reliable technique, not only for the detection and delimitation of brain tumors, but also for confirmation of presence or absence of residual tumor, facilitating total resection of the lesion.

  10. The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery

    International Nuclear Information System (INIS)

    Valdés Olmos, R. A.; Van Leeuwen, F. W. B.; Vidal-Sicart, S.; Giammarile, F.; Zaknun, J. J.; Mariani, G.

    2014-01-01

    The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In

  11. The GOSTT concept and hybrid mixed/virtual/augmented reality environment radioguided surgery.

    Science.gov (United States)

    Valdés Olmos, R A; Vidal-Sicart, S; Giammarile, F; Zaknun, J J; Van Leeuwen, F W; Mariani, G

    2014-06-01

    The popularity gained by the sentinel lymph node (SLN) procedure in the last two decades did increase the interest of the surgical disciplines for other applications of radioguided surgery. An example is the gamma-probe guided localization of occult or difficult to locate neoplastic lesions. Such guidance can be achieved by intralesional delivery (ultrasound, stereotaxis or CT) of a radiolabelled agent that remains accumulated at the site of the injection. Another possibility rested on the use of systemic administration of a tumour-seeking radiopharmaceutical with favourable tumour accumulation and retention. On the other hand, new intraoperative imaging devices for radioguided surgery in complex anatomical areas became available. All this a few years ago led to the delineation of the concept Guided intraOperative Scintigraphic Tumour Targeting (GOSTT) to include the whole spectrum of basic and advanced nuclear medicine procedures required for providing a roadmap that would optimise surgery. The introduction of allied signatures using, e.g. hybrid tracers for simultaneous detection of the radioactive and fluorescent signals did amply the GOSTT concept. It was now possible to combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. This hybrid approach is currently in progress and probably will become an important model to follow in the coming years. A cornerstone in the GOSTT concept is constituted by diagnostic imaging technologies like SPECT/CT. SPECT/CT was introduced halfway the past decade and was immediately incorporated into the SLN procedure. Important reasons attributing to the success of SPECT/CT were its combination with lymphoscintigraphy, and the ability to display SLNs in an anatomical environment. This latter aspect has significantly been improved in the new generation of SPECT/CT cameras and provides the base for the novel mixed reality protocols of image-guided surgery. In

  12. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications.

    Science.gov (United States)

    Tsuchimochi, Makoto; Sakahara, Harumi; Hayama, Kazuhide; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 mm. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (99mTc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56 +/- 0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  13. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimochi, Makoto; Hayama, Kazuhide [Department of Oral and Maxillofacial Radiology, The Nippon Dental University School of Dentistry at Niigata, 1-8 Hamaura-cho, 951-8580, Niigata (Japan); Sakahara, Harumi [Department of Radiology, Hamamatsu University School of Medicine, Hamamatsu (Japan); Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi [Acrorad Co. Ltd., Tokyo (Japan); Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar [Integrated Detector and Electronics A.S (IDE AS), Hovik (Norway)

    2003-12-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ({sup 99m}Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56{+-}0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and

  14. A prototype small CdTe gamma camera for radioguided surgery and other imaging applications

    International Nuclear Information System (INIS)

    Tsuchimochi, Makoto; Hayama, Kazuhide; Sakahara, Harumi; Funaki, Minoru; Ohno, Ryoichi; Shirahata, Takashi; Orskaug, Terje; Maehlum, Gunnar; Yoshioka, Koki; Nygard, Einar

    2003-01-01

    Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mm x 166 mm x 65 mm. The effective visual field was 44.8 mm x 44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV ( 99m Tc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56±0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating

  15. Radioguided surgery for breast cancer- preliminary experience in Piaui, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Benedita; Melo, Nayana; Vieira, Sabas; Abreu, Evandro; Abreu, Joao Batista de Abreu; Padua Filho, Antonio de [Centro Bionuclear de Diagnostico, Teresina, PI (Brazil); Universidade Estadual do Piaui, Teresina, PI (Brazil); Universidade Federal do Piaui, Teresina, PI (Brazil); Hospital Sao Marcos, Teresina, PI (Brazil); E-mail: bionuclear@uol.com.br

    2005-10-15

    Intraoperatory detection and excision of sentinel lymph node (SLN), radio guided occult lesion localization (ROLL) and lesional resection, or a combination of these two procedures at one time in a same patient (SNOLL), are techniques that represent, at the moment, a significant advance in breast cancer surgery, procedures in clinical practice being established, as can be seen from the medical literature, as well as in this institution. Thirty one patients with breast cancer were initially treated with the aid of radio guided surgery. Of those, 20 patients were submitted to sentinel lymph node biopsy, six have undergone only ROLL and five were submitted to a combination of the two techniques. (author)

  16. Radioguided surgery for breast cancer- preliminary experience in Piaui, Brazil

    International Nuclear Information System (INIS)

    Abreu, Benedita; Melo, Nayana; Vieira, Sabas; Abreu, Evandro; Abreu, Joao Batista de Abreu; Padua Filho, Antonio de

    2005-01-01

    Intraoperatory detection and excision of sentinel lymph node (SLN), radio guided occult lesion localization (ROLL) and lesional resection, or a combination of these two procedures at one time in a same patient (SNOLL), are techniques that represent, at the moment, a significant advance in breast cancer surgery, procedures in clinical practice being established, as can be seen from the medical literature, as well as in this institution. Thirty one patients with breast cancer were initially treated with the aid of radio guided surgery. Of those, 20 patients were submitted to sentinel lymph node biopsy, six have undergone only ROLL and five were submitted to a combination of the two techniques. (author)

  17. Radio-guided surgery for removal of a giant parathyroid cyst related to hyperthyroidism

    International Nuclear Information System (INIS)

    Fuentes Valdes, Edelberto; Escarpanter Gonzalez, Julio C; Lopez Diaz, Adlin; Alfonso Trujillo, Yiovanni; Infante Amoros, Adalberto; Dominguez lvarez, Carlos A; Palau San Pedro, Aley

    2009-01-01

    Among present advances of surgical treatment of hyperthyroidism is the preoperative localization of hyper-functioning glands by preoperative and intraoperative scan, this later one by a special gamma probe. By the other hand, parathyroid cysts are rare; may be of functioning type or not, as well as the findings of 99mTc-MIBI, and the intraoperative use of gamma probe to assess all the possible sites where could be hyperproductive glands of parathyroid hormone. We describe features of management, safety, and administration of radiological agent during the immediate preoperative period, as well as use of gamma probe during intervention. Evolution over follow-up is reported. This case represents the third patient operated on from hyperthyroidism by radio-guided surgery in our center, which introduced this technique in our country. (Author)

  18. Radioguided surgery: First experiences with surgical gamma probe

    International Nuclear Information System (INIS)

    Vereb, M.; Bakala, J.

    2004-01-01

    Full text: Thanks to the International Atomic Energy Agency and co-operation of the Nuclear Regulatory Authority of the Slovak Republic - International and Public Relations Division, sentinel lymph node detection has been introduced in one of the regional hospitals in Slovakia. Surgical Gamma Probe, the equipment needed for this has been made available. IAEA first of all helped in organizing a workshop on Scintimammography, Sentinel Lymph Node Detection and Intra-Operative Surgical Probe in Breast Cancer, in April 2002. Education of specialists - surgeons, oncologists, and pathologists and of course radiologists helped them to better understand the subject visa-vis nuclear medicine techniques. We also started the sentinel node detection following the two-days protocol. A 57 years old female with newly detected breast carcinoma in right breast, with positive mammography was investigated. Axillary lymph nodes were not palpable. Tc-99m Nanocoll, with particles size ranging 4-100 nm, was administered, 75 MBq peritumorally + 75 MBq subdermally and a dynamic lymphoscintigraphy was acquired which showed migration of the radiotracer. Static views (after 120 min.) demonstrated 4 sentinel lymph nodes in the right axilla. No lymph node was seen in the internal mammary or left axillary region. Next day before operation about 2 ml of patten blue dye was injected around the tumor and breast was compressed for about 10 min. Identification of sentinel lymph node was done with the help of surgical gamma probe and blue tinting. We found 6 nodes, first two were not really sentinel, but they were blue. A breast conservation surgery with standard axillary lymphadenectomy was performed. Pathology revealed invasive ductal carcinoma. We understand the need to establish an algorithm of examination and treatment of patients with newly diagnosed breast carcinoma. This technology requires teamwork of surgeon, nuclear medicine physician and pathologist. Regarding radiation exposure which every

  19. Radioguided surgery of primary hyperparathyroidism in a population with a high prevalence of thyroid pathology

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Talavera, Paloma [University Hospital of Valladolid, Department of Nuclear Medicine, Valladolid (Spain); Gonzalez, Carmen; Gomez, Alberto [University Hospital of Salamanca, Department of Surgery, Salamanca (Spain); Garcia-Talavera, Jose Ramon; Martin, Esther; Martin, Mariano [University Hospital of Salamanca, Department of Nuclear Medicine, Salamanca (Spain)

    2010-11-15

    Patients with concomitant thyroid pathology are usually excluded from minimally invasive radioguided parathyroidectomy (MIRP). We assessed the value in these patients of the gamma probe, alone or in combination with other techniques, in MIRP and unilateral or bilateral approaches. We evaluated its performance in association with intraoperative determination of intact parathyroid hormone (ioPTHi) and preoperative {sup 99m}Tc-MIBI dual phase scintigraphy. Included in the study were 87 patients with a diagnosis of primary hyperparathyroidism who underwent radioguided surgery. They were divided into two groups depending on the presence of concomitant thyroid pathology (TP group, 33 patients) or absence of concomitant thyroid pathology (NTP group, 54 patients). In the TP group, ioPTHi achieved the highest accuracy (90.9%), followed by the gamma probe (81.8%) and scintigraphy (69.7%). In the NTP group, the probe (94.4%) performed better than ioPTH and scintigraphy (both 85.2%). In the TP group, scintigraphy in combination with the gamma probe had a success rate of 90.9%, and 94% in combination with ioPTHi. The three techniques are applied together had a success rate of 97%. For all patients undergoing MIRP, the probe alone worked well, irrespective of the presence or absence of concomitant thyroid pathology. Patients with concomitant thyroid pathology should not be a priori excluded from a MIRP, as long as other adjuvant techniques (scintigraphy or ioPTHi) are used in conjunction with the gamma probe. In these patients, the probe can also be helpful in unilateral or bilateral surgery. (orig.)

  20. Radioguided surgery of primary hyperparathyroidism in a population with a high prevalence of thyroid pathology

    International Nuclear Information System (INIS)

    Garcia-Talavera, Paloma; Gonzalez, Carmen; Gomez, Alberto; Garcia-Talavera, Jose Ramon; Martin, Esther; Martin, Mariano

    2010-01-01

    Patients with concomitant thyroid pathology are usually excluded from minimally invasive radioguided parathyroidectomy (MIRP). We assessed the value in these patients of the gamma probe, alone or in combination with other techniques, in MIRP and unilateral or bilateral approaches. We evaluated its performance in association with intraoperative determination of intact parathyroid hormone (ioPTHi) and preoperative 99m Tc-MIBI dual phase scintigraphy. Included in the study were 87 patients with a diagnosis of primary hyperparathyroidism who underwent radioguided surgery. They were divided into two groups depending on the presence of concomitant thyroid pathology (TP group, 33 patients) or absence of concomitant thyroid pathology (NTP group, 54 patients). In the TP group, ioPTHi achieved the highest accuracy (90.9%), followed by the gamma probe (81.8%) and scintigraphy (69.7%). In the NTP group, the probe (94.4%) performed better than ioPTH and scintigraphy (both 85.2%). In the TP group, scintigraphy in combination with the gamma probe had a success rate of 90.9%, and 94% in combination with ioPTHi. The three techniques are applied together had a success rate of 97%. For all patients undergoing MIRP, the probe alone worked well, irrespective of the presence or absence of concomitant thyroid pathology. Patients with concomitant thyroid pathology should not be a priori excluded from a MIRP, as long as other adjuvant techniques (scintigraphy or ioPTHi) are used in conjunction with the gamma probe. In these patients, the probe can also be helpful in unilateral or bilateral surgery. (orig.)

  1. Feasibility of a wireless gammar probe in radioguided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Min; Kim, Jeong Ho; Park, Chan Jong; Joo, Koan Sik [Dept. of Physics, University of Myongji, Seoul (Korea, Republic of)

    2016-04-15

    Nuclear medicine is divided into two major domains: diagnosis and therapy. Nuclear medicine diagnostic procedures are used for determining and evaluating the physiological, chemical, endocrinal, and metabolic conditions of organs or tissues. Tumors can be diagnosed based on the images provided by the associated machinery; after diagnosis, sometimes these tumors can be surgically removed. Currently, to help guide the surgeon to the exact location of the tumor site, the use of intraoperative probes has steadily gained popularity. These probes allow the physician to locate the tumor on the basis of the higher uptake of the preoperatively injected radio pharmaceutical within the site, as compared to the surrounding tissue. Direct detection offers very good energy resolution, but the detection efficiency is low; on the other hand, indirect detection presents high efficiency and low energy resolution. For this reason, the use of both detectors is recommended for obtaining an accurate localization of the diagnostic and therapeutic fields. In the literature, there are several works that aim to develop a suitable probe that presents such characteristics (i.e., good resolution, high detection efficiency, as well as the capacity for miniaturization). In this study, a wireless gamma probe is designed for the detection of tumors of the tissue surface using a silicon photomultiplier (SiPM) and a cerium-doped gadolinium aluminum gallium garnet (Ce:GAGG) scintillator. Our experiments demonstrate the feasibility of wireless diagnostics, as well as the suitable energy resolution and spatial resolution. The system developed based on the results of this study is expected to perform intraoperative or diagnostic evaluations of residual lesions (or the absence thereof) and its quantitative distribution in the affected area, thus contributing to wireless diagnostics and screening systems.

  2. Radioguided breast surgery for occult lesion localization – correlation between two methods

    Directory of Open Access Journals (Sweden)

    Gutfilen Bianca

    2008-08-01

    Full Text Available Abstract Background The detection of sub-clinical breast lesions has increased with screening mammography. Biopsy techniques can offer precision and agility in its execution, as well as patient comfort. This trial compares radioguided occult lesion localization (ROLL and wire-guided localization (WL of breast lesions. We investigate if a procedure at the ambulatorial level (ROLL could lead to a better aesthetic result and less postoperative pain. In addition, we intend to demonstrate the efficacy of radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions and correlate radiological and histopathological findings. Methods One hundred and twenty patients were randomized into two groups (59 WL and 61 ROLL. The patients were requested to score the cosmetic appearance of their breast after surgery, and a numerical rating scale was used to measure pain on the first postoperative day. Clearance margins were considered at ≥ 10 mm for invasive cancer, ≥ 5 mm for ductal carcinoma in situ, and ≥ 1 mm for benign disease. Patients were subsequently treated according to the definitive histological result. When appropriate, different statistical tests were used in order to test the significance between the two groups, considering a P value Results WL and ROLL located all the occult breast lesions successfully. In the ROLL group, the specimen volume was smaller and there were more cases with clear margins (P Conclusion ROLL is an effective method for the excision of non-palpable breast lesions. It enables more careful planning of the cutaneous incision, leading to better aesthetic results, less postoperative symptoms, and smaller volumes of excised tissue.

  3. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  4. Surgery with radioguided location of a liver metastasis of melanoma choroid: case report; Cirurgia com localizacao radioguiada de uma metastase hepatica de melanoma de coroide: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Marcelo; Miranda, Mario Henrique Furlanetto, E-mail: mmoreno@unochapeco.edu.br, E-mail: mirandamario@unochapeco.edu.br [Universidade Comunitaria da Regiao de Chapeco (UNOCHAPECO), SC (Brazil)

    2015-04-15

    Introduction: The use of radioguided occult lesion localization prior to surgical excision is increasing, mainly due to the development of new probes and the use of PET-CT. Case report: A 70-year-old male who presented with a metastatic lesion in his liver from a choroidal melanoma. This was located using PET-CT and subsequently located with a low-energy intraoperative gamma probe during the laparotomy. Conclusion: The present case shows that it is possible to excise a hepatic metastasis utilizing the principles of radioguided surgery, even in centers without access to high energy probes. (author)

  5. Association of Parathyroid Gland Biopsy Excision Technique With Ex Vivo Radiation Counts During Radioguided Parathyroid Surgery.

    Science.gov (United States)

    Hinson, Andrew M; Lawson, Bradley R; Franco, Aime T; Stack, Brendan C

    2017-06-01

    Parathyroid biopsy represents a means for normal and hyperfunctional glands to be distinguished intraoperatively. However, no data exist to guide surgeons regarding how much of a parathyroid gland must be biopsied to satisfy the 20% rule. To quantify the relative proportion of a hyperfunctional parathyroid gland that must be evaluated with the gamma probe to satisfy the 20% rule. A retrospective review of surgical data for 24 consecutive patients (16 women, 18 men; mean [SD] age, 66.6 [10] years; range, 51-83 years) who underwent surgery for primary hyperparathyroidism between May and October, 2015, in a tertieary academic medical center. Extirpated parathyroid glands were sectioned into parallel or pie-shaped biopsies and evaluated ex vivo with a gamma probe to determine what percentage of a hyperfunctional gland must be sampled to meet the Norman 20% rule. The hypothesis was formulated during data collection. In total, 253 ex vivo biopsy specimens were obtained from 33 surgically removed parathyroid glands. Parathyroid biopsies satisfied the 20% rule with an accuracy that depended on the relative proportion of the parent gland represented: half or more (96.6%; 95% CI, 91.7%-100.0%), a quarter to one-half (87.0%; 95% CI, 79.3%-94.7%), less than a quarter (63.6%; 95% CI, 54.5%-72.8%). When less than a quarter of the gland was removed, pie-shaped biopsies were more likely to satisfy the 20% rule compared with parallel biopsies of the same weight (78.4% vs 56.2%; absolute difference, 22.2%; 95% CI, 4.7%-39.7%). Unless half of a parathyroid gland is biopsied during radioguided parathyroidectomy, the 20% rule cannot reliably rule out the presence of a hyperfunctional parathyroid lesion. Pie-shaped biopsies originating from the center of the gland are associated with a lower rate of false-negative results compared with peripheral biopsies of similar size. Pie-shaped biopsies and biopsy of half or more of each nonexcised parathyroid gland for ex vivo counts may increase

  6. Comparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery.

    Science.gov (United States)

    Chapman, Gregg J; Povoski, Stephen P; Hall, Nathan C; Murrey, Douglas A; Lee, Robert; Martin, Edward W

    2014-09-13

    Intraoperative in situ identification of (18)F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal (18)F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal (18)F-FDG-avid tissue sites during (18)F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal (18)F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.

  7. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  8. Radioguided parathyroidectomy for tertiary hyperparathyroidism.

    Science.gov (United States)

    Somnay, Yash R; Weinlander, Eric; Alfhefdi, Amal; Schneider, David; Sippel, Rebecca S; Chen, Herbert

    2015-05-15

    Tertiary hyperparathyroidism (3HPT) is defined as the persistent hyperproduction of parathyroid hormone and resulting hypercalcemia after renal transplantation. Here, we examine the utility of radioguided parathyroidectomy (RGP) in patients with 3HPT. We reviewed a prospective surgery database containing 80 3HPT patients who underwent RGP from January 2001-July 2014 at our institution. We evaluated patient demographics, operative management, radioguided neoprobe utilization, and operative outcomes. Data are reported as mean ± standard error of the mean. The mean age of the patients was 52 ± 1 y, and 46% were male. A total of 69 patients had hyperplasia and received subtotal parathyroidectomy, whereas 5 patients had double adenomas and 6 patients had single adenomas. The average calcium level among 3HPT patients was 10.8 ± 0.1 mg/dL preoperatively and 8.7 ± 0.1 mg/dL postoperatively. In vivo radioguided counts normalized to background counts averaged 145 ± 4%, whereas ex vivo counts normalized to background counts averaged 69 ± 5%. All but one ex vivo count was >20%. Ectopically located glands were successfully localized in 38 patients using the gamma probe. Ex vivo percentage did not correlate with parathyroid gland weight, preoperative parathyroid hormone, or preoperative calcium. Our radioguided approach achieved normocalcemia in 96% of 3HPT patients undergoing RGP; two patients developed recurrent disease. In this series, all enlarged parathyroid glands were localized and resected using the gamma probe. Thus, RGP reliably localizes adenomatous, hyperplastic, and ectopically located glands in patients with 3HPT, resulting in high cure rate after resection. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Use of {sup 99m}Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature

    Energy Technology Data Exchange (ETDEWEB)

    Denmeade, Kristie A [Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia); Constable, Chris [Brain and Mind Research Institute, University of Sydney, New South Wales (Australia); Reed, Warren M [Discipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney, New South Wales (Australia); Nuclear Medicine and Ultrasound Department, Bankstown-Lidcombe Hospital, Bankstown, New South Wales (Australia)

    2013-06-15

    The use of technetium-99m 2-methoxyisobutyl isonitrile ({sup 99m}Tc MIBI) for assistance in minimally invasive radioguided surgery (MIRS) is growing in popularity as a safe, effective, and proficient technique used for parathyroidectomy in primary hyperparathyroidism (PHPT) treatment. Previously, the preferred treatment for PHPT was bilateral neck exploration (BNE), a very invasive, costly, and lengthy procedure. However, as a large majority (80–85% of cases of PHPT) are attributed to a single parathyroid adenoma (PA), a simpler more direct technique such as MIRS is a far better option. The following article is an exploration of the current literature concerning varied protocols utilizing {sup 99m}Tc MIBI for assistance in MIRS for patients undergoing treatment of PHPT. This technique boasts many advantageous outcomes for patients suffering from PHPT. These include a reduction in cost, operating time, and patient recovery; less evidence of post-surgical hypocalcaemia, less pain, and complications; superior cosmetic results; same-day discharge; and the possibility of local anaesthesia which is particularly beneficial in elderly patients. Better outcomes for patients with deep or ectopic PAs, reduced intra-operative complications, and improved cosmetic outcomes for patients who have previously undergone thyroid and/or parathyroid surgery are also advantageous. Of the literature reviewed it was also found that no patients suffered any major surgical complications such as laryngeal nerve palsy or permanent hypoparathyroidism using {sup 99m}Tc MIBI for assistance in MIRS.

  10. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract.

    Science.gov (United States)

    Hubalewska-Dydejczyk, A; Kulig, J; Szybinski, P; Mikolajczak, R; Pach, D; Sowa-Staszczak, A; Fröss-Baron, K; Huszno, B

    2007-10-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue "marked" by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [(99m)Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [(99m)Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [(99m)Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [(99m)Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology.

  11. Radio-guided surgery with the use of [99mTc-EDDA/HYNIC]octreotate in intra-operative detection of neuroendocrine tumours of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Hubalewska-Dydejczyk, A.; Kulig, J.; Szybinski, P.; Mikolajczak, R.; Pach, D.; Sowa-Staszczak, A.; Froess-Baron, K.; Huszno, B.

    2007-01-01

    Radio-guided surgery (RGS) is an intra-operative localising technique which enables identification of tissue ''marked'' by a specific radiotracer injected before surgery. It is mainly used for sentinel node mapping and for detection of parathyroid adenomas and other tumours, including neuroendocrine tumours of the gastrointestinal tract (GEP-NET). The aim of this study was to determine whether intra-operative radio-detection with the use of [ 99m Tc-EDDA/HYNIC]octreotate, a new somatostatin analogue, is able to reveal an unknown primary and secondary sites, thereby improving surgical treatment and the final outcome of GEP-NET. The study group included nine patients with suspected GEP-NET (four carcinoids, five pancreatic NET) localised with somatostatin receptor scintigraphy (with [ 99m Tc-EDDA/HYNIC]octreotate), who had negative results on other pre-operative imaging tests. At surgery, suspected tumours were measured in situ and ex vivo and precise exploration of the abdominal cavity was performed with the intra-operative scintillation detector (Navigator). Intra-operative gamma counting localised three carcinoids. In one patient SRS was false positive (owing to inflammatory infiltration). Compared with SRS, RGS revealed additional lymph node metastases in one case. RGS resulted in successful localisation of all pancreatic NET (the smallest lesion was 8 mm in diameter). [ 99m Tc-EDDA/HYNIC]octreotate SRS followed by RGS is a promising technique to improve the rate of detection and efficacy of treatment of GEP-NET, especially in the presence of occult endocrine tumours. The imaging properties of [ 99m Tc-EDDA/HYNIC]octreotate and the 1-day imaging protocol offer opportunities for more widespread application of this tracer followed by RGS in oncology. (orig.)

  12. Incremental value of combined 99MTc tetrofosmin parathyroid scintigraphy, rapid intra operative PTH assays and minimally invasive radio-guided surgery (MIRS) in optimizing parathyroidectomies

    International Nuclear Information System (INIS)

    Padma, S.; Kumar, S.; Babu, T.; Kumar, H.; Nair, V.; Nair, G.K.

    2004-01-01

    Objective: Aim of our study was to evaluate incremental diagnostic value of 99mTc Tetrofosmin parathyroid SPECT (TPSPECT), rapid intra operative quick parathyroid hormone measurement (QPTH) combined with radio guidance provided by scintillation probe (Minimally Invasive Radio guided Surgery MIRS) in parathyroid surgeries. While TPSPECT is an established investigation in preoperative workup of hyperparathyroidism patients , MIRS is a relatively new concept in Indian subcontinent. Methods: 29 pts (M: F = 18: 11), age range 16- 65 yrs (mean 41+ 9 yrs) having clinical and biochemical hyperparathyroidism underwent TPSPECT between Jan 02 -04, using 20 mci IV 99mTc Tetrofosmin. Pts with familial hyperparathyroidism , previous nodular goiters and previous neck irradiation were excluded from study. Scintigraphy comprised of immediate, delayed planar and SPECT imaging of neck and chest. Imagewise abnormal, persistent tracer uptake was considered positive for adenoma and diffuse uptake for hyperplasia. 26 pts underwent exploration (22 adenomas and 4 hyperplasias).18 pts had benefit of intraoperative QPTH. A select group (after Dec 2003) i.e. 9 pts got the assistance of radioguided probing. Peroperatively NM physician used cordless handheld gamma probe (Gamma Finder, World of Medicine, Germany) in neck and mediastinum to detect parathyroid adenoma / hyperplasias. A five fold increase in radioactive counts perceived by probe when compared to background was considered positive for parathyroid adenoma / hyperplasia. If PTH levels fell from baseline by at least 50%, the surgery was concluded as complete. Results: In all 22 pts suspected to have primary hyperparathyroidism TPSPECT identified adenomas (100 % sensitivity). While planar imaging had a sensitivity of 90.1% (20/22 pts), SPECT identified the adenoma in all pts. Interestingly only 3/22 pts had ectopic glands while 5 had more than one adenomas. The most commonly involved gland was left inferior. In secondary

  13. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    International Nuclear Information System (INIS)

    Scopinaro, F.; Capriotti, G.; Di Santo, G.; Capotondi, C.; Micarelli, A.; Massari, R.; Trotta, C.; Soluri, A.

    2006-01-01

    The diagnosis of diabetic foot osteomyelitis is often difficult. 99m Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm 2 FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. 99m Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot

  14. High-resolution mini gamma camera for diagnosis and radio-guided surgery in diabetic foot infection

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capriotti, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Di Santo, G. [Department of Radiological Sciences, University ' La Sapienza' Rome (Italy); Capotondi, C. [Unit of Radiology, S. Andrea Hospital, Rome (Italy); Micarelli, A. [Nuclear Medicine, Sulmona Hospital, Sulmona (AQ) (Italy); Massari, R. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Trotta, C. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy); Soluri, A. [Institute of Biomedical Engineering, ISIB-CNR, Rome-Li-tech srl, Lauzacco Pavia di Udine (UD) (Italy)]. E-mail: soluri@isib.cnr.it

    2006-12-20

    The diagnosis of diabetic foot osteomyelitis is often difficult. {sup 99m}Tc-WBC (White Blood Cell) scintigraphy plays a key role in the diagnosis of bone infections. Spatial resolution of Anger camera is not always able to differentiate soft tissue from bone infection. Aim of present study is to verify if HRD (High-Resolution Detector) is able to improve diagnosis and to help surgery. Patients were studied by HRD showing 25.7x25.7 mm{sup 2} FOV, 2 mm spatial resolution and 18% energy resolution. The patients were underwent to surgery and, when necessary, bone biopsy, both guided by HRD. Four patients were positive at Anger camera without specific signs of osteomyelitis. HRS (High-Resolution Scintigraphy) showed hot spots in the same patients. In two of them the hot spot was bar-shaped and it was localized in correspondence of the small phalanx. The presence of bone infection was confirmed at surgery, which was successfully guided by HRS. {sup 99m}Tc-WBC HRS was able to diagnose pedal infection and to guide the surgery of diabetic foot, opening a new way in the treatment of infected diabetic foot.

  15. Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    International Nuclear Information System (INIS)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia; Al-Nahhas, Adil; Boni, Giuseppe; Mariani, Giuliano; Pelizzo, Maria R.

    2006-01-01

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of 99m Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or 99m Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session 99m Tc-pertechnetate/ 99m Tc-sestamibi planar subtraction scintigraphy, followed by 99m Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of 99m Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) 99m Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p 99m Tc-sestamibi SPECT is more accurate in predicting the intraoperative measurements with the gamma probe. In this respect, a preoperative 99m Tc-sestamibi SPECT acquisition should be recommended for better selection of PHPT patients in whom

  16. Role of {sup 99m}Tc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia [Istituto Oncologico Veneto (IOV), Nuclear Medicine Service - PET Unit, ' S. Maria della Misericordia' Hospital, Rovigo (Italy); Al-Nahhas, Adil [Hammersmith Hospital, Department of Nuclear Medicine, London (United Kingdom); Boni, Giuseppe; Mariani, Giuliano [University of Pisa Medical School, Regional Center of Nuclear Medicine, Pisa (Italy); Pelizzo, Maria R. [University of Padova Medical School, Department of Special Surgery, Padova (Italy)

    2006-09-15

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of {sup 99m}Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or {sup 99m}Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session {sup 99m}Tc-pertechnetate/{sup 99m}Tc-sestamibi planar subtraction scintigraphy, followed by {sup 99m}Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of {sup 99m}Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) {sup 99m}Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p<0.01) but no correlation was found with planar scintigraphic data. Our preliminary data suggest that measurement of the P/B ratio by means of {sup 99m}Tc-sestamibi SPECT is more accurate in predicting the

  17. Cirugía radioguiada para la extirpación de un quiste paratiroideo gigante con hiperparatiroidismo Radio-guided surgery for removal of a giant parathyroid cyst related to hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Edelberto Fuentes Valdés

    2009-04-01

    Full Text Available Entre los avances actuales del tratamiento quirúrgico del hiperparatiroidismo se encuentra la localización preoperatoria de la(s glándula(s hiperfuncionante(s mediante gammagrafía preoperatoria e intraoperatoria, esta última a través de una sonda gamma especial. Por otro lado, los quistes paratiroideos son raros; pueden ser funcionantes o no. Se describe un nuevo caso de quiste paratiroideo hiperfuncionante, así como los hallazgos de la gammagrafía con 99mTc-MIBI y el uso intraoperatorio de la sonda gamma para evaluar todos los sitios probables donde pudieran existir glándulas hiperproductoras de hormona paratiroidea. Se describen aspectos de la manipulación, seguridad y administración del radiofármaco en el período preoperatorio inmediato, así como la utilización de la sonda gamma durante la intervención. Se informa la evolución durante el seguimiento. Este caso representa el tercer paciente intervenido por hiperparatiroidismo mediante cirugía radioguiada en nuestro centro, institución en la que se introdujo esta técnica en el paísAmong present advances of surgical treatment of hyperthyroidism is the preoperative localization of hyper-functioning glands by preoperative and intraoperative scan, this later one by a special gamma probe. By the other hand, parathyroid cysts are rare; may be of functioning type or not, as well as the findings of 99mTc-MIBI, and the intraoperative use of gamma probe to assess all the possible sites where could be hyperproductive glands of parathyroid hormone. We describe features of management, safety, and administration of radiological agent during the immediate preoperative period, as well as use of gamma probe during intervention. Evolution over follow-up is reported. This case represents the third patient operated on from hyperthyroidism by radio-guided surgery in our center, which introduced this technique in our country.

  18. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control.

    Science.gov (United States)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-09-18

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  19. Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control

    International Nuclear Information System (INIS)

    Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian

    2013-01-01

    Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a

  20. Robotic systems in spine surgery.

    Science.gov (United States)

    Onen, Mehmet Resid; Naderi, Sait

    2014-01-01

    Surgical robotic systems have been available for almost twenty years. The first surgical robotic systems were designed as supportive systems for laparoscopic approaches in general surgery (the first procedure was a cholecystectomy in 1987). The da Vinci Robotic System is the most common system used for robotic surgery today. This system is widely used in urology, gynecology and other surgical disciplines, and recently there have been initial reports of its use in spine surgery, for transoral access and anterior approaches for lumbar inter-body fusion interventions. SpineAssist, which is widely used in spine surgery, and Renaissance Robotic Systems, which are considered the next generation of robotic systems, are now FDA approved. These robotic systems are designed for use as guidance systems in spine instrumentation, cement augmentations and biopsies. The aim is to increase surgical accuracy while reducing the intra-operative exposure to harmful radiation to the patient and operating team personnel during the intervention. We offer a review of the published literature related to the use of robotic systems in spine surgery and provide information on using robotic systems.

  1. Sentinel nodes in complex areas: innovating radioguided surgery

    NARCIS (Netherlands)

    Vermeeren, L.

    2011-01-01

    De eerste lymfeklier die in contact staat met een tumor noemt men de schildwachtklier. Door middel van een biopsie onderzoekt men deze klier om te kijken of sprake is van uitzaaiingen. Lenka Vermeeren beschrijft beeldvormende technieken om identificatie van schildwachtklieren te optimaliseren.

  2. Lymphoscintigraphy and radioguided surgery in cervical and vulvar malignant tumours

    International Nuclear Information System (INIS)

    Morales Guzman-Barron, Rosanna E.

    2006-01-01

    Objective: To validate a combined technique in the detection of sentinel nodes in early cervix and vulvar cancer patients. Material and Methods: Seventy patients, 24 to 63 years old (average 40 years), with cervical cancer stages IA2, IB1 and IIA, and fourteen patients, 28 to 80 years old (median 68 years) with vulval neoplasm, stage I and II, had sentinel node (SN) detection using lymphoscintigraphy and a gamma probe in the surgical room, after injection of Tc 99m dextran and patent blue dye. Sentinel nodes were seen between 20 and 135 minutes after injection, in cervical cancer, and between one and sixty minutes in vulvar neoplasms. In patients with cervical tumors, 99 sentinel nodes were localized in the obturator region, 28 were interiliac, nine were located in the external iliac region, three in the common iliac region and one was found in perineum. In patients with a vulvar neoplasm, all sentinel nodes were located in the superficial inguinal region. The detection rate was 98,8% for cervical cancer and 100% for vulvar neoplasms, with bilateral drainage in 46% and 29% respectively. Metastases were found in 10,4% (7/65) of IB1 stage cervical cancer patients (6 squamous cell carcinomas - non keratinizing: 5, keratinizing: 1 and one adenocarcionoma) and none in four patients with IA2 stage (with non keratinizing squamous cell carcinoma). The patients with IIA stage cervical cancer (keratinizing squamous cell carcinoma) had metastases in the SN. Three out of 14 patients with vulvar cancer showed metastases in the sentinel node. Two of them had epidermoid carcinoma and one, malignant melanoma. There were no metastases in non-sentinel nodes when sentinel nodes were negative for metastases, both in cervical or vulvar cancer. Conclusion: It is feasible to localize sentinel nodes in cervical and vulvar cancer, using a combined technique with Tc 99m Dextran and 'patent blue'. (author)

  3. Systems workplace for endoscopic surgery.

    Science.gov (United States)

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  4. New applications of radio guided surgery in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Chojniak, Rubens [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Image], e-mail: almirgvb@yahoo.com.br; Lima, Eduardo Nobrega Pereira [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Nuclear Medicine

    2009-07-01

    Objective: To report oncological cases (excluding those related to breast cancer) for which radioguided surgery has been used in combination with the Radioguided Occult Lesion Localization technique. Introduction: Radioguided surgery enables a surgeon to identify lesions or tissues that have been preoperatively marked with radioactive substances. The Radioguided Occult Lesion Localization technique has been widely used to identify the sentinel lymph node and occult lesions in patients with breast cancer. However, few studies have reported the use of this technique for non-breast cancer pathologies. Methodology: In all cases, injection of Technetium-99m sulfur colloid was performed, directly inside or near by the suspicious lesion, guided by ultrasound or computed tomography, up to 36 hours prior to the surgical procedure. Intraoperative lesion detection was carried out using a gamma-probe. Results: We report five oncology cases in which preoperative markings of the lesions were carried out using the Radioguided Occult Lesion Localization technique. The patients presented with the following: recurrence of renal cell carcinoma, cervical recurrence of papillary carcinoma of the thyroid, recurrence of retroperitoneal sarcoma, lesions of the popliteal fossa, and recurrence of rhabdomyosarcoma of a thigh. In each case, the lesions that were marked preoperatively were ultimately successfully excised. Conclusions: Radioguided surgery has proven to be a safe and effective alternative for the management of oncology patients. The Radioguided Occult Lesion Localization technique can be useful in selected cases where suspect lesions may be difficult to identify intraoperatively, due to their dimensions or anatomical location. The procedure allows for more conservative excisions and reduces the surgery-related morbidity. (author)

  5. Radioguided sentinel node biopsy with 99mTc colloidal (Re) sulphide: Our experience

    International Nuclear Information System (INIS)

    Lago, G.; Alonso, O.; Aizen, B.; Juri, C.

    2004-01-01

    Full text: It has been demonstrated that nodal metastases from different solid tumors are not random events. Tumour spread within the regional draining basin has been shown to progress in an orderly fashion with first draining basin (sentinel node) most likely to have metastatic involvement. Thus, the sentinel node examination accurately reflects the histology of the remainder of the lymphatic basin. Sentinel node biopsy (SLB) with previous lymphatic mapping by means of radiocolloid lymphoscintraphy has been proposed by many authors as a routine method for staging the regional lymph nodes in patients with cutaneous melanoma and breast cancer. A positive SLB is found to carry high prognostic significance and identifies those patients who might benefit from early therapeutic lymph node dissection and adjuvant treatment. The aim of this retrospective study was to evaluate our experience with radioguided SLB in patients with different tumours. We studied 154 patients between 1998-2003, with clinically localized breast cancer (n=45), melanoma (n=82), cervix carcinoma (n=22) and penis carcinoma (n=5). Lymphoscintigraphy was performed 6-18 hours before surgery using a LFOV gamma camera equipped with a LEHR collimator. A dose of 111-185 MBq of 99mTc colloidal sulphide (Nanocis, Cis bio international, Gif-Sur-Yvette, France) was injected around the primary lesion (melanoma, breast cancer, and penis carcinoma) and into the four quadrants of the cervix (cervix carcinoma). All basins identified by lymphoscintigraphy were explored through incisions directed by the use of a gamma probe. Radioactivity (counts /sec) of the sentinel node(s) and the adjacent tissues was measured in-vivo and verified ex-vivo after removal. A signal to background ratio higher than 2 to 3 in-vivo and higher than 10 ex-vivo was considered significant. Blue dye mapping was performed in all cases of breast cancer but left at discretion of the surgeon for the remaining tumours. Serial sections of the

  6. Systemic hypertension and non-cardiac surgery.

    Science.gov (United States)

    Misra, Satyajeet

    2017-09-01

    Primary systemic hypertension affects 10%-25% of individuals presenting for surgery and anaesthesia and constitutes an important cause of cancellation of elective surgeries. Much of the fear stems from the fact that hypertension may lead to adverse perioperative outcomes. Although long-standing hypertension increases the risk of stroke, renal dysfunction or major adverse cardiovascular events, the same is usually not seen in the perioperative period if blood pressure is <180/110 mmHg and this has been the overriding theme in the recent guidelines on perioperative blood pressure management. Newer concepts include isolated systolic hypertension and pulse pressure hypertension that are increasingly used to stratify risk. The aim of this review is to focus on the adult patient with chronic primary systemic hypertension posted for elective non-cardiac surgery and outline the perioperative concerns.

  7. iROLL: does 3-D radioguided occult lesion localization improve surgical management in early-stage breast cancer?

    Science.gov (United States)

    Bluemel, Christina; Cramer, Andreas; Grossmann, Christoph; Kajdi, Georg W; Malzahn, Uwe; Lamp, Nora; Langen, Heinz-Jakob; Schmid, Jan; Buck, Andreas K; Grimminger, Hanns-Jörg; Herrmann, Ken

    2015-10-01

    To prospectively evaluate the feasibility of 3-D radioguided occult lesion localization (iROLL) and to compare iROLL with wire-guided localization (WGL) in patients with early-stage breast cancer undergoing breast-conserving surgery and sentinel lymph node biopsy (SLNB). WGL (standard procedure) and iROLL in combination with SLNB were performed in 31 women (mean age 65.1 ± 11.2 years) with early-stage breast cancer and clinically negative axillae. Patient comfort in respect of both methods was assessed using a ten point scale. SLNB and iROLL were guided by freehand SPECT (fhSPECT). The results of the novel 3-D image-based method were compared with those of WGL, ultrasound-based lesion localization, and histopathology. iROLL successfully detected the malignant primary and at least one sentinel lymph node in 97% of patients. In a single patient (3%), only iROLL, and not WGL, enabled lesion localization. The variability between fhSPECT and ultrasound-based depth localization of breast lesions was low (1.2 ± 1.4 mm). Clear margins were achieved in 81% of the patients; however, precise prediction of clear histopathological surgical margins was not feasible using iROLL. Patients rated iROLL as less painful than WGL with a pain score 0.8 ± 1.2 points (p localizing early-stage breast cancer in the course of breast-conserving surgery, and is a suitable replacement for WGL. As a single image-based procedure for localization of breast lesions and sentinel nodes, iROLL may improve the entire surgical procedure. However, no advantages of the image-guided procedure were found with regard to prediction of complete tumour resection.

  8. iROLL: does 3-D radioguided occult lesion localization improve surgical management in early-stage breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Bluemel, Christina; Kajdi, Georg W.; Schmid, Jan; Buck, Andreas K.; Herrmann, Ken [University Hospital of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Cramer, Andreas; Grossmann, Christoph; Grimminger, Hanns-Joerg [Missionsaerztliches Klinikum Wuerzburg, Department of Obstetrics and Gynecology, Wuerzburg (Germany); Malzahn, Uwe [University of Wuerzburg, Institute of Clinical Epidemiology and Biometry, Wuerzburg (Germany); Lamp, Nora [University of Wuerzburg, Institute of Pathology, Wuerzburg (Germany); Langen, Heinz-Jakob [Missionsaerztliches Klinikum Wuerzburg, Department of Radiology, Wuerzburg (Germany)

    2015-10-15

    To prospectively evaluate the feasibility of 3-D radioguided occult lesion localization (iROLL) and to compare iROLL with wire-guided localization (WGL) in patients with early-stage breast cancer undergoing breast-conserving surgery and sentinel lymph node biopsy (SLNB). WGL (standard procedure) and iROLL in combination with SLNB were performed in 31 women (mean age 65.1 ± 11.2 years) with early-stage breast cancer and clinically negative axillae. Patient comfort in respect of both methods was assessed using a ten point scale. SLNB and iROLL were guided by freehand SPECT (fhSPECT). The results of the novel 3-D image-based method were compared with those of WGL, ultrasound-based lesion localization, and histopathology. iROLL successfully detected the malignant primary and at least one sentinel lymph node in 97 % of patients. In a single patient (3 %), only iROLL, and not WGL, enabled lesion localization. The variability between fhSPECT and ultrasound-based depth localization of breast lesions was low (1.2 ± 1.4 mm). Clear margins were achieved in 81 % of the patients; however, precise prediction of clear histopathological surgical margins was not feasible using iROLL. Patients rated iROLL as less painful than WGL with a pain score 0.8 ± 1.2 points (p < 0.01) lower than the score for iROLL. iROLL is a well-tolerated and feasible technique for localizing early-stage breast cancer in the course of breast-conserving surgery, and is a suitable replacement for WGL. As a single image-based procedure for localization of breast lesions and sentinel nodes, iROLL may improve the entire surgical procedure. However, no advantages of the image-guided procedure were found with regard to prediction of complete tumour resection. (orig.)

  9. Novel technology of molecular radio-guidance for lymph node dissection in recurrent prostate cancer by PSMA-ligands.

    Science.gov (United States)

    Rauscher, Isabel; Horn, Thomas; Eiber, Matthias; Gschwend, Jürgen E; Maurer, Tobias

    2018-04-01

    Recently, prostate-specific membrane antigen-radioguided surgery (PSMA-RGS) has been introduced as a promising new and individual treatment concept in patients with localised recurrent prostate cancer (PC). In the following, we want to review our experience with PSMA-RGS in patients with localised biochemical recurrent PC. A non-systematic review of the literature was carried out with focus on technical and logistical aspects of PSMA-RGS. Furthermore, published data on intraoperative detection of metastatic lesions compared to preoperative PSMA-PET and postoperative histopathology, postoperative complications as well as oncological follow-up data are summarized. Finally, relevant aspects on prerequisites for PSMA-RGS, patient selection, and the potential benefit of additional salvage radiotherapy or potential future applications of robotic PSMA-RGS with drop-in γ-probes are discussed. First results show that PSMA-RGS is very sensitive and specific in tracking suspicious lesions intraoperatively. Prerequisite for patient selection and localisation of tumour recurrence is a positive Ga-HBED-CC PSMA positron-emission tomography (PET) scan with preferably only singular soft tissue or lymph node recurrence after primary treatment. Furthermore, PSMA-RGS has the potential to positively influence oncological outcome. PSMA-RGS seems to be of high value in patients with localised PC recurrence for exact localisation and resection of oftentimes small metastatic lesions using intraoperative and ex vivo γ-probe measurements. However, patient identification on the basis of Ga-HBED-CC-PSMA PET imaging as well as clinical parameters is crucial to obtain satisfactory results.

  10. Comparison of Different Computer–Aided Surgery Systems in Skull Base Surgery

    OpenAIRE

    Ecke, U.; Luebben, B.; Maurer, J.; Boor, S.; Mann, W. J.

    2003-01-01

    Computer–aided surgery (CAS) based on high–resolution imaging techniques represents an important adjunct to precise intraoperative orientation when anatomical landmarks are distorted or missing. Several commercial systems, mostly based on optical or electromagnetic navigation principles, are on the market. This study investigated the application of EasyGuide®, VectorVision®, and InstaTrak® CAS systems in ENT surgery under practical and laboratory conditions. System accuracy, time required, ha...

  11. Application of da Vinci surgical robotic system in hepatobiliary surgery

    Directory of Open Access Journals (Sweden)

    Chen Jiahai

    2018-01-01

    Full Text Available The development of minimally invasive surgery has brought a revolutionary change to surgery techniques, and endoscopic surgical robots, especially Da Vinci robotic surgical system, has further broaden the scope of minimally invasive surgery, which has been applied in a variety of surgical fields including hepatobiliary surgery. Today, the application of Da Vinci surgical robot can cover most of the operations in hepatobiliary surgery which has proved to be safe and practical. What’s more, many clinical studies in recent years have showed that Da Vinci surgical system is superior to traditional laparoscopy. This paper summarize the advantage and disadvantage of Da Vinci surgical system, and outlines the current status of and future perspectives on the robot-assisted hepatobiliary surgery based on the cases reports in recent years of the application of Da Vinci surgical robot.

  12. The lacrimal system: diagnosis, management, and surgery

    National Research Council Canada - National Science Library

    Cohen, Adam J; Mercandetti, Michael; Brazzo, Brian G

    2006-01-01

    ... and techniques presented represent the state of the art of lacrimal diagnosis and surgery. There is mention of lacrimal infection dating back to the Code of Hammurabi in 2250 BC, but it was not until the late 1800s that real progress began to be made. Toti, an ENT surgeon in Florence, Italy, described external dacryocystorhinostomy (DCR) with turb...

  13. Sentinel Node Detection in Head and Neck Malignancies: Innovations in Radioguided Surgery

    Directory of Open Access Journals (Sweden)

    L. Vermeeren

    2009-01-01

    Full Text Available Sentinel node mapping is becoming a routine procedure for staging of various malignancies, because it can determine lymph node status more precisely. Due to anatomical problems, localizing sentinel nodes in the head and neck region on the basis of conventional images can be difficult. New diagnostic tools can provide better visualization of sentinel nodes. In an attempt to keep up with possible scientific progress, this article reviews new and innovative tools for sentinel node localization in this specific area. The overview comprises a short introduction of the sentinel node procedure as well as indications in the head and neck region. Then the results of SPECT/CT for sentinel node detection are described. Finally, a portable gamma camera to enable intraoperative real-time imaging with improved sentinel node detection is described.

  14. Development of voltage sensitivity preamplifier to application in radioguided surgical probe

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da; Rela, Paulo Roberto; Hamada, Margarida Mizue

    2005-01-01

    The methods of nuclear medicine are increasing used to complement standard diagnostic examinations. Some of these are radioguided detection of the sentinel lymph node (SN) and the radioguided localization of occult lesions. The SN technique is used in a small-size breast carcinoma and involves the identification, removal and immediate histological examination. Specifically, particles of colloidal human serum albumin are labelled with low activities of 99m Tc and are inoculated into the breast lesion or close in the case of SN biopsy. Subsequently, a hand-held gamma-ray detecting probe with reduced dimensions is used to locate the lesion or the SN as a hot spot and guide its surgical removal. Many techniques can be used for gamma-ray probes development. Gamma photons can be either directly detected via high atomic numbers semiconductors detectors or indirect detection, as scintillator crystal converts gamma photons into light photons. In all of them, the preamplifier is used as close as possible to the detector for obtaining a good energy resolution and due to the necessary small probe dimension, the preamplifier must have reduced size. The commercial preamplifiers are not small enough to be assembled inside the probe. It was developed a not usually preamplifier configuration for high-resolution spectroscopy energy, adequate in size to be set up in gamma-ray probes. This tension preamplifier can be split between the gamma-ray probe and the read out unit. Due to this configuration the effective size required inside the probe was reduced. The results and the probe assembling are showed in this work. (author)

  15. Implementation of an interactive liver surgery planning system

    Science.gov (United States)

    Wang, Luyao; Liu, Jingjing; Yuan, Rong; Gu, Shuguo; Yu, Long; Li, Zhitao; Li, Yanzhao; Li, Zhen; Xie, Qingguo; Hu, Daoyu

    2011-03-01

    Liver tumor, one of the most wide-spread diseases, has a very high mortality in China. To improve success rates of liver surgeries and life qualities of such patients, we implement an interactive liver surgery planning system based on contrastenhanced liver CT images. The system consists of five modules: pre-processing, segmentation, modeling, quantitative analysis and surgery simulation. The Graph Cuts method is utilized to automatically segment the liver based on an anatomical prior knowledge that liver is the biggest organ and has almost homogeneous gray value. The system supports users to build patient-specific liver segment and sub-segment models using interactive portal vein branch labeling, and to perform anatomical resection simulation. It also provides several tools to simulate atypical resection, including resection plane, sphere and curved surface. To match actual surgery resections well and simulate the process flexibly, we extend our work to develop a virtual scalpel model and simulate the scalpel movement in the hepatic tissue using multi-plane continuous resection. In addition, the quantitative analysis module makes it possible to assess the risk of a liver surgery. The preliminary results show that the system has the potential to offer an accurate 3D delineation of the liver anatomy, as well as the tumors' location in relation to vessels, and to facilitate liver resection surgeries. Furthermore, we are testing the system in a full-scale clinical trial.

  16. [Orthopedic and trauma surgery in the German DRG System 2007].

    Science.gov (United States)

    Franz, D; Kaufmann, M; Siebert, C H; Windolf, J; Roeder, N

    2007-03-01

    The German Diagnosis-Related Groups (DRG) System was further developed into its 2007 version. For orthopedic and trauma surgery, significant changes were made in terms of the coding of diagnoses and medical procedures, as well as in the DRG structure itself. The German Societies for Trauma Surgery and for Orthopedics and Orthopedic Surgery (Deutsch Gesellschaft für Unfallchirurgie, DGU; and Deutsche Gesellschaft für Orthopädie und Orthopädische Chirurgie, DGOOC) once again cooperated constructively with the German DRG Institute InEK. Among other innovations, new International Classification of Diseases (ICD) codes for second-degree burns were implemented. Procedure codes for joint operations, endoprosthetic-surgery and spine surgery were restructured. Furthermore, a specific code for septic surgery was introduced in 2007. In addition, the DRG structure was improved. Case allocation of patients with more than one significant operation was established. Further DRG subdivisions were established according to the patients age and the Patient Clinical Complexity Level (PCCL). DRG developments for 2007 have improved appropriate case allocation, but once again increased the system's complexity. Clinicians need an ever growing amount of specific coding know-how. Still, further adjustments to the German DRG system are required to allow for a correct allocation of cases and funds.

  17. Towards ubiquitous access of computer-assisted surgery systems.

    Science.gov (United States)

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  18. [Hand surgery in the German DRG System 2007].

    Science.gov (United States)

    Franz, D; Windolf, J; Kaufmann, M; Siebert, C H; Roeder, N

    2007-05-01

    Hand surgery often needs only a short length of stay in hospital. Patients' comorbidity is low. Many hand surgery procedures do not need inpatient structures. Up until 2006 special procedures of hand surgery could not be coded. The DRG structure did not separate very complex and less complex operations. Specialized hospitals needed a proper case allocation of their patients within the G-DRG system. The DRG structure concerning hand surgery increased in version 2007 of the G-DRG system. The main parameter of DRG splitting is the complexity of the operation. Furthermore additional criteria such as more than one significant OR procedure, the patients' age, or special diagnoses influence case allocation. A special OPS code for complex cases treated with hand surgery was implemented. The changes in the DRG structure and the implementation of the new OPS code for complex cases establish a strong basis for the identification of different patient costs. Different case allocation leads to different economic impacts on departments of hand surgery. Whether the new OPS code becomes a DRG splitting parameter has to be calculated by the German DRG Institute for further DRG versions.

  19. Historical contributions from the Harvard system to adult spine surgery.

    Science.gov (United States)

    Schoenfeld, Andrew J

    2011-10-15

    Literature review. To document the historical contributions from the Harvard Medical School system to the field of adult spine surgery. Despite the fact that significant contributions to the discipline of spinal surgery have derived from the Harvard system, no prior study documents the history of the Harvard spine services in a cohesive narrative. This historical perspective reviews the history of adult spine surgery within the Harvard system and outlines the significant contributions made by orthopedic and neurosurgical practitioners to the field. Literature reviews were performed from historical works, as well as scientific publications to fashion a cohesive review covering the history of spine surgery at Harvard from the early 19th century to the present. The development of the spine surgical services at the three main Harvard hospitals, and significant spine surgical personalities within the system, are discussed, including W. Jason Mixter, MD, Joseph S. Barr Sr., MD, and Marius N. Smith-Petersen, MD. Substantial developments that have arisen from the Harvard teaching hospitals include the recognition of disc herniation as the cause of radicular symptoms in the lower extremities, the description of lumbar discectomy as a surgical treatment for radicular pain, osteotomy for the correction of spinal deformity, and the first attempt to create a systematic algorithm capable of informing treatment for cervical spine trauma. Despite humble beginnings, the surgeons and scientists at Harvard have influenced nearly every facet of spine surgery over the course of the last two centuries.

  20. Haptic feedback designs in teleoperation systems for minimal invasive surgery

    NARCIS (Netherlands)

    Font, I.; Weiland, S.; Franken, M.; Steinbuch, M.; Rovers, A.F.

    2004-01-01

    One of the major shortcomings of state-of-the-art robotic systems for minimal invasive surgery is the lack of haptic feedback for the surgeon. In order to provide haptic information, sensors and actuators have to be added to the master and slave device. A control system should process the data and

  1. Extending topological surgery to natural processes and dynamical systems.

    Directory of Open Access Journals (Sweden)

    Stathis Antoniou

    Full Text Available Topological surgery is a mathematical technique used for creating new manifolds out of known ones. We observe that it occurs in natural phenomena where a sphere of dimension 0 or 1 is selected, forces are applied and the manifold in which they occur changes type. For example, 1-dimensional surgery happens during chromosomal crossover, DNA recombination and when cosmic magnetic lines reconnect, while 2-dimensional surgery happens in the formation of tornadoes, in the phenomenon of Falaco solitons, in drop coalescence and in the cell mitosis. Inspired by such phenomena, we introduce new theoretical concepts which enhance topological surgery with the observed forces and dynamics. To do this, we first extend the formal definition to a continuous process caused by local forces. Next, for modeling phenomena which do not happen on arcs or surfaces but are 2-dimensional or 3-dimensional, we fill in the interior space by defining the notion of solid topological surgery. We further introduce the notion of embedded surgery in S3 for modeling phenomena which involve more intrinsically the ambient space, such as the appearance of knotting in DNA and phenomena where the causes and effect of the process lies beyond the initial manifold, such as the formation of black holes. Finally, we connect these new theoretical concepts with a dynamical system and we present it as a model for both 2-dimensional 0-surgery and natural phenomena exhibiting a 'hole drilling' behavior. We hope that through this study, topology and dynamics of many natural phenomena, as well as topological surgery itself, will be better understood.

  2. The University Münster Model Surgery System for Orthognathic Surgery. Part II -- KD-MMS.

    Science.gov (United States)

    Ehmer, Ulrike; Joos, Ulrich; Ziebura, Thomas; Flieger, Stefanie; Wiechmann, Dirk

    2013-01-04

    Model surgery is an integral part of the planning procedure in orthognathic surgery. Most concepts comprise cutting the dental cast off its socket. The standardized spacer plates of the KD-MMS provide for a non-destructive, reversible and reproducible means of maxillary and/or mandibular plaster cast separation. In the course of development of the system various articulator types were evaluated with regard to their capability to provide a means of realizing the concepts comprised of the KD-MMS. Special attention was dedicated to the ability to perform three-dimensional displacements without cutting of plaster casts. Various utilities were developed to facilitate maxillary displacement in accordance to the planning. Objectives of this development comprised the ability to implement the values established in the course of two-dimensional ceph planning. The system - KD-MMS comprises a set of hardware components as well as a defined procedure. Essential hardware components are red spacer and blue mounting plates. The blue mounting plates replace the standard yellow SAM mounting elements. The red spacers provide for a defined leeway of 8 mm for three-dimensional movements. The non-destructive approach of the KD-MMS makes it possible to conduct different model surgeries with the same plaster casts as well as to restore the initial, pre-surgical situation at any time. Thereby, surgical protocol generation and gnathologic splint construction are facilitated. The KD-MMS hardware components in conjunction with the defined procedures are capable of increasing efficiency and accuracy of model surgery and splint construction. In cases where different surgical approaches need to be evaluated in the course of model surgery, a significant reduction of chair time may be achieved.

  3. Preliminary development of augmented reality systems for spinal surgery

    Science.gov (United States)

    Nguyen, Nhu Q.; Ramjist, Joel M.; Jivraj, Jamil; Jakubovic, Raphael; Deorajh, Ryan; Yang, Victor X. D.

    2017-02-01

    Surgical navigation has been more actively deployed in open spinal surgeries due to the need for improved precision during procedures. This is increasingly difficult in minimally invasive surgeries due to the lack of visual cues caused by smaller exposure sites, and increases a surgeon's dependence on their knowledge of anatomical landmarks as well as the CT or MRI images. The use of augmented reality (AR) systems and registration technologies in spinal surgeries could allow for improvements to techniques by overlaying a 3D reconstruction of patient anatomy in the surgeon's field of view, creating a mixed reality visualization. The AR system will be capable of projecting the 3D reconstruction onto a field and preliminary object tracking on a phantom. Dimensional accuracy of the mixed media will also be quantified to account for distortions in tracking.

  4. Radio-guided localization of clinically occult breast lesions (ROLL): a DGH experience

    International Nuclear Information System (INIS)

    Thind, C.R.; Desmond, S.; Harris, O.; Nadeem, R.; Chagla, L.S.; Audisio, R.A.

    2005-01-01

    AIM: Wire-guided localization (WGL) of clinically occult breast lesions is a well established technique. The aim of this study was to evaluate radio-guided localization (ROLL) within the breast screening service of a district general hospital. METHOD: The study group comprised 70 women who underwent ROLL under US and stereotaxis. This required an injection of Technetium-labelled colloidal albumen into the impalpable breast lesion. The women then proceeded to theatre, where localization was achieved with the use of a gamma probe. The lesion was identified by the presence of a high signal, caused by the injected isotope. The results of 70 consecutive cases in which a breast lesion was localized using ROLL were compared with the results of the latest 70 WGLs. RESULTS: All 140 lesions were successfully localized. However, the change in technique from WGL to ROLL offered significant benefits to patients. CONCLUSION: Our study demonstrated that ROLL is a practical and reliable localization technique. It can be implemented in hospital units without using valuable gamma camera time. The cost compares well with WGL. There is an improved cosmetic outcome for patients, and the very small quantity of radioactivity used is safe for both patients and staff

  5. Acute systemic inflammatory response after cardiac surgery in ...

    African Journals Online (AJOL)

    2017-09-03

    Sep 3, 2017 ... valve(s) replacement were enrolled, from a single center hospital, after informed consent was obtained. C-reactive ... Cite as: Gojo MKE, Prakaschandra R. Acute systemic inflammatory response after cardiac surgery in patients infected with human im- ..... Arroyo-Espliguero R, Avanzas P, Cosín-Sales J, Al-.

  6. Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures

    International Nuclear Information System (INIS)

    Povoski, Stephen P.; Martin, Edward W.; Sarikaya, Ismet; Hall, Nathan C.; Knopp, Michael V.; White, William C.; Marsh, Steven G.; Hinkle, George H.

    2008-01-01

    The purpose of the current study was to comprehensively evaluate occupational radiation exposure to all intraoperative and perioperative personnel involved in radioguided surgical procedures utilizing 18 F-fluorodeoxyglucose ( 18 F-FDG). Radiation exposure to surgeon, anesthetist, scrub technologist, circulating nurse, preoperative nurse, and postoperative nurse, using aluminum oxide dosimeters read by optically stimulated luminescence technology, was evaluated during ten actual radioguided surgical procedures involving administration of 18 F-FDG. Mean patient dosage of 18 F-FDG was 699 ± 181 MBq (range 451-984). Mean time from 18 F-FDG injection to initial exposure of personnel to the patient was shortest for the preoperative nurse (75 ± 63 min, range 0-182) followed by the circulating nurse, anesthetist, scrub technologist, surgeon, and postoperative nurse. Mean total time of exposure of the personnel to the patient was longest for the anesthetist (250 ± 128 min, range 69-492) followed by the circulating nurse, scrub technologist, surgeon, postoperative nurse, and preoperative nurse. Largest deep dose equivalent per case was received by the surgeon (164 ± 135 μSv, range 10-580) followed by the anesthetist, scrub technologist, postoperative nurse, circulating nurse, and preoperative nurse. Largest deep dose equivalent per hour of exposure was received by the preoperative nurse (83 ± 134 μSv/h, range 0-400) followed by the surgeon, anesthetist, postoperative nurse, scrub technologist, and circulating nurse. On a per case basis, occupational radiation exposure to intraoperative and perioperative personnel involved in 18 F-FDG radioguided surgical procedures is relatively small. Development of guidelines for monitoring occupational radiation exposure in 18 F-FDG cases will provide reassurance and afford a safe work environment for such personnel. (orig.)

  7. Mathematical model of bone drilling for virtual surgery system

    Science.gov (United States)

    Alaytsev, Innokentiy K.; Danilova, Tatyana V.; Manturov, Alexey O.; Mareev, Gleb O.; Mareev, Oleg V.

    2018-04-01

    The bone drilling is an essential part of surgeries in ENT and Dentistry. A proper training of drilling machine handling skills is impossible without proper modelling of the drilling process. Utilization of high precision methods like FEM is limited due to the requirement of 1000 Hz update rate for haptic feedback. The study presents a mathematical model of the drilling process that accounts the properties of materials, the geometry and the rotation rate of a burr to compute the removed material volume. The simplicity of the model allows for integrating it in the high-frequency haptic thread. The precision of the model is enough for a virtual surgery system targeted on the training of the basic surgery skills.

  8. Travel patterns of cancer surgery patients in a regionalized system.

    Science.gov (United States)

    Smith, Andrew K; Shara, Nawar M; Zeymo, Alexander; Harris, Katherine; Estes, Randy; Johnson, Lynt B; Al-Refaie, Waddah B

    2015-11-01

    Regionalization of complex surgeries has increased patient travel distances possibly leaving a substantial burden on those at risk for poorer surgical outcomes. To date, little is known about travel patterns of cancer surgery patients in regionalized settings. To inform this issue, we sought to assess travel patterns of those undergoing a major cancer surgery within a regionalized system. We identified 4733 patients who underwent lung, esophageal, gastric, liver, pancreatic, and colorectal resections from 2002-2014 within a multihospital system in the Mid-Atlantic region of the United States. Patient age, race and/or ethnicity, and insurance status were extracted from electronic health records. We used Geographical Information System capabilities in R software to estimate travel distance and map patient addresses based on cancer surgery type and these characteristics. We used visual inspection, analysis of variance, and interaction analyses to assess the distribution of travel distances between patient populations. A total of 48.2% of patients were non-white, 49.9% were aged >65 y, and 54.9% had private insurance. Increased travel distance was associated with decreasing age and those undergoing pancreatic and esophageal resections. Also, black patients tend to travel shorter distances than other racial and/or ethnic groups. These maps offer a preliminary understanding into variations of geospatial travel patterns among patients receiving major cancer surgery in a Mid-Atlantic regionalized setting. Future research should focus on the impact of regionalization on timely delivery of surgical care and other quality metrics. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  10. Surgery of the eloquent area using neuronavigation system

    International Nuclear Information System (INIS)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira

    2001-01-01

    The efficacy of a neuronavigation system for surgery of lesions near Broca's area (6 patients), skull base (5 patients), or paracentral sulcus (10 patients) was evaluated in this study. Using the neuronavigation system, three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus obtained by MRI and CT. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm. 3D reconstructed images were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. The precentral gyri identified by 3D reconstructed brain images coincided well with that identified by fMRI. In lesions near Broca's area, skull base, and paracentral sulcus, 3D reconstructed brain images were very useful for both the preoperative surgical simulation and the intraoperative neuronavigation to preserve the postoperative neurological function and to perform less invasive surgery. (author)

  11. 99mTc-MIBI radio-guided minimally invasive parathyroidectomy: experience with patients with normal thyroids and nodular goiters.

    Science.gov (United States)

    Casara, Dario; Rubello, Domenico; Cauzzo, Cristina; Pelizzo, Maria Rosa

    2002-01-01

    The surgical approach to primary hyperparathyroidism (HPT) is changing. In patients with a high probability to be affected by a solitary parathyroid adenoma (PA), a unilateral neck exploration (UNE) or a minimally invasive radio-guided surgery (MIRS) using the intraoperative gamma probe (IGP) technique have recently been proposed. We investigated the role of IGP in a group of 84 patients with primary HPT who were homogeneously evaluated before surgery by a single-day imaging protocol including 99mTcO4/MIBI subtraction scan and neck ultrasound (US) and then operated on by the same surgical team. Quick parathyroid hormone (QPTH) was intraoperatively measured in all cases to confirm successful parathyroidectomy. In 70 patients with scan/US evidence of a single enlarged parathyroid gland (EPG) and with a normal thyroid gland, MIRS was planned. In the other 14 patients, the IGP technique was utilized during a standard bilateral neck exploration (BNE) because of the presence of concomitant nodular goiter (11 cases) or multiglandular disease (MGD) (3 cases). The IGP technique consisted of the following: (1) in the operating room, a low 99mTc-MIBI dose (37 MBq) was injected intravenously during anesthesia induction; (2) subsequently, the patient's neck was scanned with the probe by the surgeon to localize the cutaneous projection of the EPG; (3) in patients who underwent MIRS, the EPG was detected intraoperatively with the probe and removed through a small, 2 to 2.5 cm skin incision; (4) radioactivity was measured on the EPG both in vivo and ex vivo, the thyroid, the background and the parathyroid bed after EPG removal. In patients with concomitant nodular goiter, the radioactivity was also measured on the thyroid nodules. Surgical and pathologic findings were consistent with a single PA in 78 patients, parathyroid carcinoma in 2, and MGD in 4. MIRS was successfully performed in 67 of the 70 patients (97.7%) in whom this approach was planned. It must be pointed out that

  12. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    Science.gov (United States)

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  13. [Orthopedic and trauma surgery in the German DRG system 2008].

    Science.gov (United States)

    Franz, D; Kaufmann, M; Siebert, C H; Windolf, J; Roeder, N

    2008-04-01

    The German DRG (diagnosis-related groups) system has been modified and updated into version 2008. For orthopedic and trauma surgery significant changes concerning coding of diagnoses, medical procedures and the DRG structure were made. The modified version has been analyzed in order to ascertain whether the DRG system is suitably qualified to fulfill the demands of the reimbursement system or whether further improvements are necessary. Analysis of the severity of relevant side-effect diagnoses, medical procedures and G-DRGs in the versions 2007 and 2008 was carried out based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2008 focused on the development of DRG structure, DRG validation and codes for medical procedures. The outcome of these changes for German hospitals may vary depending on the range of activities. G-DRG system has become even more complex and the new regulations have also resulted in new problems associated with complications.. High demands are made on correct and complete coding of complex orthopedic and trauma surgery cases. Quality of case allocation within the G-DRG system has been improved. Nevertheless, further improvements of the G-DRG system are necessary, especially for cases with severe injuries.

  14. A goggle navigation system for cancer resection surgery

    Science.gov (United States)

    Xu, Junbin; Shao, Pengfei; Yue, Ting; Zhang, Shiwu; Ding, Houzhu; Wang, Jinkun; Xu, Ronald

    2014-02-01

    We describe a portable fluorescence goggle navigation system for cancer margin assessment during oncologic surgeries. The system consists of a computer, a head mount display (HMD) device, a near infrared (NIR) CCD camera, a miniature CMOS camera, and a 780 nm laser diode excitation light source. The fluorescence and the background images of the surgical scene are acquired by the CCD camera and the CMOS camera respectively, co-registered, and displayed on the HMD device in real-time. The spatial resolution and the co-registration deviation of the goggle navigation system are evaluated quantitatively. The technical feasibility of the proposed goggle system is tested in an ex vivo tumor model. Our experiments demonstrate the feasibility of using a goggle navigation system for intraoperative margin detection and surgical guidance.

  15. Assessment of the Mexican Board of Pediatric Surgery Certification System.

    Science.gov (United States)

    Porras-Hernandez, Juan D; Mora-Fol, Jose R; Lezama-Del Valle, Pablo; Yanowsky-Reyes, Guillermo; Perez-Lorenzana, Hector; Ortega-Salgado, Arturo; Aguirre-Jauregui, Oscar; Bracho-Blanchet, Eduardo; Sanchez-Mendiola, Melchor

    2015-01-01

    To evaluate the quality of the Mexican Board of Pediatric Surgery (MBPS) certifying system, using contemporary international guidelines. Retrospective assessment of evidence collected during the design and implementation processes of 2 consecutive applications of the MBPS certifying examination, using Cizek's checklist for evaluating credential-testing programs. It includes the relevant guidelines from the American Education Research Association, the American Psychological Association, the National Council on Measurement in Education, and the National Commission for Certifying Agencies. Four independent and previously trained raters used the checklist. They underwent a 2-week training using frame-of-reference and performance dimensions methodologies. Certification examinations of MBPS. The 2013 and 2014 MBPS certification examinations, with 111 evidence items of the processes, followed for the assessment of 86 examinees. The checklist internal consistency was 0.89. Absolute interrater agreement was 0.34 for the 2013 and 0.66 for the 2014 editions of the examination. The 2013 examination complied with 55 (64%) of the checklist 86 items, in 2014 with 72 (84%). In 2014, the certifying system reached a quality of 84%. For optimal fulfillment of its social responsibility, the MBPS is required to maintain its level of quality and attempt to improve its performance. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Risk-adjusted scoring systems in colorectal surgery.

    Science.gov (United States)

    Leung, Edmund; McArdle, Kirsten; Wong, Ling S

    2011-01-01

    Consequent to recent advances in surgical techniques and management, survival rate has increased substantially over the last 25 years, particularly in colorectal cancer patients. However, post-operative morbidity and mortality from colorectal cancer vary widely across the country. Therefore, standardised outcome measures are emphasised not only for professional accountability, but also for comparison between treatment units and regions. In a heterogeneous population, the use of crude mortality as an outcome measure for patients undergoing surgery is simply misleading. Meaningful comparisons, however, require accurate risk stratification of patients being analysed before conclusions can be reached regarding the outcomes recorded. Sub-specialised colorectal surgical units usually dedicated to more complex and high-risk operations. The need for accurate risk prediction is necessary in these units as both mortality and morbidity often are tools to justify the practice of high-risk surgery. The Acute Physiology And Chronic Health Evaluation (APACHE) is a system for classifying patients in the intensive care unit. However, APACHE score was considered too complex for general surgical use. The American Society of Anaesthesiologists (ASA) grade has been considered useful as an adjunct to informed consent and for monitoring surgical performance through time. ASA grade is simple but too subjective. The Physiological & Operative Severity Score for the enUmeration of Mortality and morbidity (POSSUM) and its variant Portsmouth POSSUM (P-POSSUM) were devised to predict outcomes in surgical patients in general, taking into account of the variables in the case-mix. POSSUM has two parts, which include assessment of physiological parameters and operative scores. There are 12 physiological parameters and 6 operative measures. The physiological parameters are taken at the time of surgery. Each physiological parameter or operative variable is sub-divided into three or four levels with

  17. Initial evaluation of a femtosecond laser system in cataract surgery.

    Science.gov (United States)

    Chang, John S M; Chen, Ivan N; Chan, Wai-Man; Ng, Jack C M; Chan, Vincent K C; Law, Antony K P

    2014-01-01

    To report the early experience and complications during cataract surgery with a noncontact femtosecond laser system. Hong Kong Sanatorium and Hospital, Hong Kong Special Administrative Region, China. Retrospective case series. All patients had anterior capsulotomy or combined anterior capsulotomy and lens fragmentation using a noncontact femtosecond laser system (Lensar) before phacoemulsification. Chart and video reviews were performed retrospectively to determine the intraoperative complication rate. Risk factors associated with the complications were also analyzed. One hundred seventy eyes were included. Free-floating capsule buttons were found in 151 eyes (88.8%). No suction break occurred in any case. Radial anterior capsule tears occurred in 9 eyes (5.3%); they did not extend to the equator or posterior capsule. One eye (0.6%) had a posterior capsule tear. No capsular block syndrome developed, and no nuclei were dropped during irrigation/aspiration (I/A). Anterior capsule tags and miosis occurred in 4 eyes (2.4%) and 17 eyes (10.0%), respectively. Different severities of subconjunctival hemorrhages developed in 71 (43.8%) of 162 eyes after the laser procedure. The mean surgical time from the beginning to the end of suction was 6.72 minutes ± 4.57 (SD) (range 2 to 28 minutes). Cataract surgery with the noncontact femtosecond laser system was safe. No eye lost vision because of complications. Caution should be taken during phacoemulsification and I/A to avoid radial anterior capsule tears and posterior capsule tears. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Robot-Assisted Fracture Surgery: Surgical Requirements and System Design.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2018-03-09

    The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.

  19. Application and development of non contact angle-wide viewing system in vitreous retinal surgery

    Directory of Open Access Journals (Sweden)

    Rong-Hua He

    2016-07-01

    Full Text Available Wide-angle viewing system as an important auxiliary device can clearly observe the whole fundus field of vision in vitreous surgery, which enable vitreoretinal surgery more efficient, safer and more effective. So it has very high application value in ophthalmologic operation. In this paper, we studied the development and application of wide-angle viewing system in vitreoretinal surgery in recent years, from which we summed up the advantage of non-contact wide-angle viewing system in clinical field, and pointed out the shortcomings. The ultimate goal is to make the non-contact wide-angle viewing system better applied in vitreous surgery.

  20. Development of a medical robot system for minimally invasive surgery.

    Science.gov (United States)

    Feng, Mei; Fu, Yili; Pan, Bo; Liu, Chang

    2012-03-01

    Robot-assisted systems have been widely used in minimally invasive surgery (MIS) practice, and with them the precision and accuracy of surgical procedures can be significantly improved. Promoting the development of robot technology in MIS will improve robot performance and help in tackling problems from complex surgical procedures. A medical robot system with a new mechanism for MIS was proposed to achieve a two-dimensional (2D) remote centre of motion (RCM). An improved surgical instrument was designed to enhance manipulability and eliminate the coupling motion between the wrist and the grippers. The control subsystem adopted a master-slave control mode, upon which a new method with error compensation of repetitive feedback can be based for the inverse kinematics solution. A unique solution with less computation and higher satisfactory accuracy was also obtained. Tremor filtration and trajectory planning were also addressed with regard to the smoothness of the surgical instrument movement. The robot system was tested on pigs weighing 30-45 kg. The experimental results show that the robot can successfully complete a cholecystectomy and meet the demands of MIS. The results of the animal experiments were excellent, indicating a promising clinical application of the robot with high manipulability. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Graphic and haptic simulation system for virtual laparoscopic rectum surgery.

    Science.gov (United States)

    Pan, Jun J; Chang, Jian; Yang, Xiaosong; Zhang, Jian J; Qureshi, Tahseen; Howell, Robert; Hickish, Tamas

    2011-09-01

    Medical simulators with vision and haptic feedback techniques offer a cost-effective and efficient alternative to the traditional medical trainings. They have been used to train doctors in many specialties of medicine, allowing tasks to be practised in a safe and repetitive manner. This paper describes a virtual-reality (VR) system which will help to influence surgeons' learning curves in the technically challenging field of laparoscopic surgery of the rectum. Data from MRI of the rectum and real operation videos are used to construct the virtual models. A haptic force filter based on radial basis functions is designed to offer realistic and smooth force feedback. To handle collision detection efficiently, a hybrid model is presented to compute the deformation of intestines. Finally, a real-time cutting technique based on mesh is employed to represent the incision operation. Despite numerous research efforts, fast and realistic solutions of soft tissues with large deformation, such as intestines, prove extremely challenging. This paper introduces our latest contribution to this endeavour. With this system, the user can haptically operate with the virtual rectum and simultaneously watch the soft tissue deformation. Our system has been tested by colorectal surgeons who believe that the simulated tactile and visual feedbacks are realistic. It could replace the traditional training process and effectively transfer surgical skills to novices. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Understanding how orthopaedic surgery practices generate value for healthcare systems.

    Science.gov (United States)

    Olson, Steven A; Mather, Richard C

    2013-06-01

    Orthopaedic surgery practices can provide substantial value to healthcare systems. Increasingly, healthcare administrators are speaking of the need for alignment between physicians and healthcare systems. However, physicians often do not understand what healthcare administrators value and therefore have difficulty articulating the value they create in discussions with their hospital or healthcare organization. Many health systems and hospitals use service lines as an organizational structure to track the relevant data and manage the resources associated with a particular type of care, such as musculoskeletal care. Understanding service lines and their management can be useful for orthopaedic surgeons interested in interacting with their hospital systems. We provide an overview of two basic types of value orthopaedic surgeons create for healthcare systems: financial or volume-driven benefits and nonfinancial quality or value-driven patient care benefits. We performed a search of PubMed from 1965 to 2012 using the term "service line." Of the 351 citations identified, 18 citations specifically involved the use of service lines to improve patient care in both nursing and medical journals. A service line is a structure used in healthcare organizations to enable management of a subset of activities or resources in a focused area of patient care delivery. There is not a consistent definition of what resources are managed within a service line from hospital to hospital. Physicians can positively impact patient care through engaging in service line management. There is increasing pressure for healthcare systems and hospitals to partner with orthopaedic surgeons. The peer-reviewed literature demonstrates there are limited resources for physicians to understand the value they create when attempting to negotiate with their hospital or healthcare organization. To effectively negotiate for resources to provide the best care for patients, orthopaedic surgeons need to claim and

  3. Surgery of the eloquent area using neuronavigation system

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira; Ono, Hidetoshi; Goto, Takumi; Aburano, Tamio [Asahikawa Medical Coll., Hokkaido (Japan)

    2001-03-01

    The purpose of this minimally invasive study was to evaluate the efficacy of a neuronavigation system for surgery of lesions near Broca's area, skull base, or paracentral sulcus. With regards to paracentral sulcus lesions, precise localization of the precentral gyrus was evaluated not only with preoperative 3D images of the brain but also confirmed by the combination of fMRI and intraoperative SEP. Using the neuronavigation system, Viewing Wand (ISG Technologies), three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus and skull representations obtained by MRI and CT. Six patients with lesions near Broca's area, 5 patients with skull base lesions, and 9 patients with lesions near the central sulcus were analyzed. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm, which was composed of repetition of rest-task every in 30 seconds for 150 seconds, in a 1.5-tesla echo-speed MR imager (Signa Horizon; General Electric Medical Systems, Milwaukee, WI). Statistical cross-correlation functional maps were generated and overlaid onto high-resolution anatomical MR images. Presurgical assessment of 3D reconstructed brain images were performed in all cases. They were analyzed in Broca's lesions, skull base lesions and paracentral sulcus lesions and were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. In fMRI, motor activation sites were obtained on both ipsilateral and contralateral hemispheres in all patients except for one patient with a hemorrhagic cyst. Locations of precentral gyri were predicted preoperatively. In all patients except for one case, fMRI was obtained even in tumor patient in whom intraoperative SEP was technically not feasible due to severe cortical brain damage from the paracentral tumor. The precentral gyri identified by 3D reconstructed brain images

  4. Surgery of the eloquent area using neuronavigation system

    International Nuclear Information System (INIS)

    Nakai, Hirofumi; Tanaka, Tatsuya; Hashizume, Kiyotaka; Hodozuka, Akira; Ono, Hidetoshi; Goto, Takumi; Aburano, Tamio

    2001-01-01

    The purpose of this minimally invasive study was to evaluate the efficacy of a neuronavigation system for surgery of lesions near Broca's area, skull base, or paracentral sulcus. With regards to paracentral sulcus lesions, precise localization of the precentral gyrus was evaluated not only with preoperative 3D images of the brain but also confirmed by the combination of fMRI and intraoperative SEP. Using the neuronavigation system, Viewing Wand (ISG Technologies), three-dimensional (3D) brain images were reconstructed by plotting cerebral sulcus and skull representations obtained by MRI and CT. Six patients with lesions near Broca's area, 5 patients with skull base lesions, and 9 patients with lesions near the central sulcus were analyzed. For paracentral sulcus lesions, patients underwent blood oxygen level-dependent fMRI while performing a finger-tapping motor paradigm, which was composed of repetition of rest-task every in 30 seconds for 150 seconds, in a 1.5-tesla echo-speed MR imager (Signa Horizon; General Electric Medical Systems, Milwaukee, WI). Statistical cross-correlation functional maps were generated and overlaid onto high-resolution anatomical MR images. Presurgical assessment of 3D reconstructed brain images were performed in all cases. They were analyzed in Broca's lesions, skull base lesions and paracentral sulcus lesions and were demonstrated to be useful for understanding the anatomical relationship between the lesions and the surrounding vital structures. In fMRI, motor activation sites were obtained on both ipsilateral and contralateral hemispheres in all patients except for one patient with a hemorrhagic cyst. Locations of precentral gyri were predicted preoperatively. In all patients except for one case, fMRI was obtained even in tumor patient in whom intraoperative SEP was technically not feasible due to severe cortical brain damage from the paracentral tumor. The precentral gyri identified by 3D reconstructed brain images coincided well

  5. Full Scale 3D Preoperative Planning System of the Ankle Joint Replacement Surgery with Multimedia System

    Directory of Open Access Journals (Sweden)

    Shuh-Ping Sun

    2014-05-01

    Full Text Available This study is intended to develop a computer-aided pre-surgical planning and simulating system in a multimedia environment for ankle joint replacement surgery. This system uses full-scale 3D reverse engineering techniques in design and development of the pre-surgical planning modules for ankle joint replacement surgery. This planning system not only develops the real-scale 3D image of the artificial ankle joint but also provides a detailed interior measurement of the ankle joint from various cutting planes. In this study, we apply the multimedia user interface to integrate different software functions into a surgical planning system with integrated functions. The functions include 3D model image acquisition, cutting, horizontal shifting and rotation of related bones (tibia and talus of the ankle joint in the predetermined time. For related bones of the ankle joint, it can also be used to design artificial ankle joints for adults in Taiwan. Those planning procedures can be recorded in this system for further research and investigation. Furthermore, since this system is a multimedia user interface, surgeons can use this system to plan and find a better and more efficient surgical approach before surgery. A database is available for this system to update and expand, which can provide different users with clinical cases as per their experience and learning.

  6. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  7. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-12-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... system (SEDASYS) submitted by Ethicon Endo-Surgery Inc. (EES), the sponsor for SEDASYS. This meeting has...

  8. Radio-fluoro guided surgery in high grade gliomas

    International Nuclear Information System (INIS)

    Lopez Piloto, Orestes; Salva Camano, Silvia; Gonzalez Gonzalez, Justo; Cruz Hernandez, Tania Margarita; Martinez Suarez, Eduardo; Lopez Arbolay, Omar; Ardisana Santana, Ernesto

    2015-01-01

    The MIBI (99mTc MIBI, methoxyisobutylisonitrile, MIBI, or sestamibi): is a wide readiness to the rich flow of photons, which improves the detection of pathological uptake with gamma probe, these physical properties make of this radiotracer the election to radioguided surgery. The sodium fluorescein is a water-soluble organic coloring substance used in the exam of the sanguine glasses of the eye. We carried out the report of five cases diagnosed with brain tumor of high grade of malignancy, with the objective to demonstrated that use of Radio-Fluro-guided Surgery (RFGS) we can achieve gross total resections without bigger deficit, completing the inclusion and exclusion criteria. The technique of RFGS demonstrated utility in the gross total resection, diminishing the residual tumor, without increasing surgery complexity and surgical times. In our study doesn't evidence of adverse effects for the administration of the radiopharmaceuticals and fluorescein

  9. Profitability analysis of a femtosecond laser system for cataract surgery using a fuzzy logic approach.

    Science.gov (United States)

    Trigueros, José Antonio; Piñero, David P; Ismail, Mahmoud M

    2016-01-01

    To define the financial and management conditions required to introduce a femtosecond laser system for cataract surgery in a clinic using a fuzzy logic approach. In the simulation performed in the current study, the costs associated to the acquisition and use of a commercially available femtosecond laser platform for cataract surgery (VICTUS, TECHNOLAS Perfect Vision GmbH, Bausch & Lomb, Munich, Germany) during a period of 5y were considered. A sensitivity analysis was performed considering such costs and the countable amortization of the system during this 5y period. Furthermore, a fuzzy logic analysis was used to obtain an estimation of the money income associated to each femtosecond laser-assisted cataract surgery (G). According to the sensitivity analysis, the femtosecond laser system under evaluation can be profitable if 1400 cataract surgeries are performed per year and if each surgery can be invoiced more than $500. In contrast, the fuzzy logic analysis confirmed that the patient had to pay more per surgery, between $661.8 and $667.4 per surgery, without considering the cost of the intraocular lens (IOL). A profitability of femtosecond laser systems for cataract surgery can be obtained after a detailed financial analysis, especially in those centers with large volumes of patients. The cost of the surgery for patients should be adapted to the real flow of patients with the ability of paying a reasonable range of cost.

  10. The university münster model surgery system for orthognathic surgery. Part II – KD-MMS

    Directory of Open Access Journals (Sweden)

    Ehmer Ulrike

    2013-01-01

    Full Text Available Abstract Background Model surgery is an integral part of the planning procedure in orthognathic surgery. Most concepts comprise cutting the dental cast off its socket. The standardized spacer plates of the KD-MMS provide for a non-destructive, reversible and reproducible means of maxillary and/or mandibular plaster cast separation. Methods In the course of development of the system various articulator types were evaluated with regard to their capability to provide a means of realizing the concepts comprised of the KD-MMS. Special attention was dedicated to the ability to perform three-dimensional displacements without cutting of plaster casts. Various utilities were developed to facilitate maxillary displacement in accordance to the planning. Objectives of this development comprised the ability to implement the values established in the course of two-dimensional ceph planning. Results The system - KD-MMS comprises a set of hardware components as well as a defined procedure. Essential hardware components are red spacer and blue mounting plates. The blue mounting plates replace the standard yellow SAM mounting elements. The red spacers provide for a defined leeway of 8 mm for three-dimensional movements. The non-destructive approach of the KD-MMS makes it possible to conduct different model surgeries with the same plaster casts as well as to restore the initial, pre-surgical situation at any time. Thereby, surgical protocol generation and gnathologic splint construction are facilitated. Conclusions The KD-MMS hardware components in conjunction with the defined procedures are capable of increasing efficiency and accuracy of model surgery and splint construction. In cases where different surgical approaches need to be evaluated in the course of model surgery, a significant reduction of chair time may be achieved.

  11. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    Science.gov (United States)

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  13. The Needs of Hybrid Systems Configuration for Real - Time Decision - Making Process in Surgery

    National Research Council Canada - National Science Library

    Tritto, G

    2001-01-01

    ...: sensors, actuators, mechatronic systems and tools in Minimally Invasive Surgery (MIS) and Microsurgery require nonlinear interpretation and control systems to interface with the computer-assisted decision making process of the surgeon at work...

  14. Clinical value of detection of intrathoracic metastatic lymph nodes with radioguided technique in patients with non-small cell lung carcinoma

    International Nuclear Information System (INIS)

    Lu Ming; Hu Yongxiao

    2008-01-01

    Objective: To study the possible clinical feasibility of intraoperative detection of metastatic lymph node with radioguided technique after labeling with 99m Tc-MIBI in patients with non-small cell lung carcinoma. Methods: Gamma-detecting probe was used intra-operatively to examine the radioactivity of lungs, regional and mediastinal nodes in 30 patients with non-small cell lung carcinoma after intravenous injection of 99m Tc-MIBI (740MBq) 30 minutes before operation for radio-labeling of the nodes. Postoperatively, the radiologically positive but conventionally pathologically negative as well as all the other nodes judged to be negative with conventional standard (altogether 201 groups) were all meticulously examined with serial sections and immunohistologic staining for detection of the presence of micro-metastasis. Results: Altogether 41 groups of nodes specimens were radiologically positive (over twofolds of normal radio-activity measured with γ probe), of which conventional pathological examination revealed metastasis in 32 groups. The remaining 9 groups of specimens were examined further with serial sections and IHC studies and micro-metastasis was found in 3 of them. Thus, the sensitivity of the radioguided technique was 100%, specificity 96.9% and accuracy rate 97.42%. In the remaining 192 radiologically negative groups of lymph nodes studied, no false negative cases (i. e. micrometastasis positive) were demonstrated. Conclusion: The radio-guided technique is very sensitive (100%), highly specific and accurate (98.9%), and 97.4% respectively), without false negativity demonstrated. Its practical clinical application seems to be feasible. (authors)

  15. Computer control versus manual control of systemic hypertension during cardiac surgery

    NARCIS (Netherlands)

    Hoeksel, S.A.A.P.; Blom, J.A.; Jansen, J.R.C.; Maessen, J.G.; Schreuder, J.J.

    2001-01-01

    Keywords:Cardiac surgery;hypertension;closed-loop controlBackground: We recently demonstrated the feasibility of computer controlled infusion of vasoactive drugs for the control of systemic hypertension during cardiac surgery. The objective of the current study was to investigate the effects of

  16. An Isolator System for minimally invasive surgery : The new design

    NARCIS (Netherlands)

    Horeman, T.; Jansen, F.W.; Dankelman, J.

    2010-01-01

    Background - The risk of obtaining a postsurgical infection depends highly on the air quality surrounding the exposed tissue, surgical instruments, and materials. Many isolators for open surgery have been invented to create a contained sterile volume around the exposed tissue. With the use of an

  17. Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies

    International Nuclear Information System (INIS)

    Vermeeren, L.; Valdes Olmos, R.A.; Vogel, W.V.; Sivro, F.; Hoefnagel, C.A.; Meinhardt, W.; Bex, A.; Poel, H.G. van der; Horenblas, S.

    2009-01-01

    Our aim was to assess the feasibility of intraoperative radioguidance with a portable gamma camera during laparoscopic sentinel node (SN) procedures in urological malignancies. We evaluated the use of the intraoperative portable gamma camera in 20 patients: 16 patients with prostate carcinoma (PCC), 2 patients with renal cell carcinoma (RC) and 2 patients with testicular cancer (TC). Intra/peritumoural injection of 99m Tc-nanocolloid ( 99m Tc) was followed by planar lymphoscintigraphy, SPECT/CT and marking of SN levels. Before laparoscopy a 125 I seed was fixed on the laparoscopic gamma probe as a pointer of SN seeking. The portable gamma camera was set to display the 99m Tc signal for SN localisation and the 125 I signal for SN seeking. Matching of these signals on screen indicated exact SN localisation, and consequently this SN was removed. The mean injected dose was 218 MBq in PCC, 228 MBq in RC and 88 MBq in TC. Pelvic SN were visualised in all PCC patients, with uncommonly located SN in seven patients. SN metastases were found in seven patients (one in a uncommonly located SN). Both RC patients and TC patients had para-aortic SN, which were all tumour free. A total of 59 SN were removed. The portable gamma camera enabled real-time SN display/identification in 18 patients (90%). The use of a portable gamma camera in combination with a laparoscopic gamma probe incorporates intraoperative real-time imaging with improved SN identification in urological malignancies. This procedure might also be useful for SN identification of other deep draining malignancies. (orig.)

  18. Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial

    International Nuclear Information System (INIS)

    Ocal, Koray; Dag, Ahmet; Turkmenoglu, Ozgur; Yucel, Erdem; Gunay, Emel Ceylan; Duce, Meltem Nass

    2011-01-01

    Aim: this prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. Methods: a total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n 56) and wire-guided localization group (n 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. Results: there were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant. Conclusions: the present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins. (author)

  19. Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Ocal, Koray; Dag, Ahmet; Turkmenoglu, Ozgur; Yucel, Erdem [Mersin University (Turkey). Medical Faculty. Dept. of General Surgery; Gunay, Emel Ceylan [Mersin University (Turkey). Medical Faculty. Dept. of Nuclear Medicine; Duce, Meltem Nass [Mersin University (Turkey). Medical Faculty. Dept. of Radiology

    2011-07-01

    Aim: this prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. Methods: a total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n 56) and wire-guided localization group (n 52). In the study, patients' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. Results: there were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of the lesions; for the wire-guided localization technique, 98%. Both localization time and operation time were significantly reduced with the ROLL technique (p = significant for all). The weight of the specimen was significantly lower in the ROLL group than in the wire-guided localization group (p = significant). The overall complication rate and pathological diagnosis were similar for both groups (p = non-significant for all). Clear margins were achieved in 91% of ROLL patients and in 53% of wire-guided localization patients, and the difference was significant. Conclusions: the present study indicated that the ROLL technique is as effective as wire-guided localization for the excision of non-palpable breast lesions. In addition, ROLL improved the outcomes by reducing localization and operation time, preventing healthy tissue excision and achieving clearer margins. (author)

  20. Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Vermeeren, L.; Valdes Olmos, R.A.; Vogel, W.V.; Sivro, F.; Hoefnagel, C.A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Meinhardt, W.; Bex, A.; Poel, H.G. van der; Horenblas, S. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands)

    2009-07-15

    Our aim was to assess the feasibility of intraoperative radioguidance with a portable gamma camera during laparoscopic sentinel node (SN) procedures in urological malignancies. We evaluated the use of the intraoperative portable gamma camera in 20 patients: 16 patients with prostate carcinoma (PCC), 2 patients with renal cell carcinoma (RC) and 2 patients with testicular cancer (TC). Intra/peritumoural injection of {sup 99m}Tc-nanocolloid ({sup 99m}Tc) was followed by planar lymphoscintigraphy, SPECT/CT and marking of SN levels. Before laparoscopy a {sup 125}I seed was fixed on the laparoscopic gamma probe as a pointer of SN seeking. The portable gamma camera was set to display the {sup 99m}Tc signal for SN localisation and the {sup 125}I signal for SN seeking. Matching of these signals on screen indicated exact SN localisation, and consequently this SN was removed. The mean injected dose was 218 MBq in PCC, 228 MBq in RC and 88 MBq in TC. Pelvic SN were visualised in all PCC patients, with uncommonly located SN in seven patients. SN metastases were found in seven patients (one in a uncommonly located SN). Both RC patients and TC patients had para-aortic SN, which were all tumour free. A total of 59 SN were removed. The portable gamma camera enabled real-time SN display/identification in 18 patients (90%). The use of a portable gamma camera in combination with a laparoscopic gamma probe incorporates intraoperative real-time imaging with improved SN identification in urological malignancies. This procedure might also be useful for SN identification of other deep draining malignancies. (orig.)

  1. [Orthopedic and trauma surgery in the German DRG system. Recent developments].

    Science.gov (United States)

    Franz, D; Schemmann, F; Selter, D D; Wirtz, D C; Roeder, N; Siebert, H; Mahlke, L

    2012-07-01

    Orthopedics and trauma surgery are subject to continuous medical advancement. The correct and performance-based case allocation by German diagnosis-related groups (G-DRG) is a major challenge. This article analyzes and assesses current developments in orthopedics and trauma surgery in the areas of coding of diagnoses and medical procedures and the development of the 2012 G-DRG system. The relevant diagnoses, medical procedures and G-DRGs in the versions 2011 and 2012 were analyzed based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes were made for the International Classification of Diseases (ICD) coding of complex cases with medical complications, the procedure coding for spinal surgery and for hand and foot surgery. The G-DRG structures were modified for endoprosthetic surgery on ankle, shoulder and elbow joints. The definition of modular structured endoprostheses was clarified. The G-DRG system for orthopedic and trauma surgery appears to be largely consolidated. The current phase of the evolution of the G-DRG system is primarily aimed at developing most exact descriptions and definitions of the content and mutual delimitation of operation and procedures coding (OPS). This is an essential prerequisite for a correct and performance-based case allocation in the G-DRG system.

  2. Systemic and Topical Use of Tranexamic Acid in Spinal Surgery: A Systematic Review

    Science.gov (United States)

    Winter, Sebastian F.; Santaguida, Carlo; Wong, Jean; Fehlings, Michael G.

    2015-01-01

    Study Design Combination of narrative and systematic literature reviews. Objectives Massive perioperative blood loss in complex spinal surgery often requires blood transfusions and can negatively affect patient outcome. Systemic use of the antifibrinolytic agent tranexamic acid (TXA) has become widely used in the management of surgical bleeding. We review the clinical evidence for the use of intravenous TXA as a hemostatic agent in spinal surgery and discuss the emerging role for its complementary use as a topical agent to reduce perioperative blood loss from the surgical site. Through a systematic review of published and ongoing investigations on topical TXA for spinal surgery, we wish to make spine practitioners aware of this option and to suggest opportunities for further investigation in the field. Methods A narrative review of systemic TXA in spinal surgery and topical TXA in surgery was conducted. Furthermore, a systematic search (using PRISMA guidelines) of PubMed (MEDLINE), EMBASE, and Cochrane CENTRAL databases as well as World Health Organization International Clinical Trials Registry Platform, ClinicalTrials.gov (National Institutes of Health), and International Standard Randomized Controlled Trial Number registries was conducted to identify both published literature and ongoing clinical trials on topical TXA in spinal surgery. Results Of 1,631 preliminary search results, 2 published studies were included in the systematic review. Out of 285 ongoing clinical trials matching the search criteria, a total of 4 relevant studies were included and reviewed. Conclusion Intravenous TXA is established as an efficacious hemostatic agent in spinal surgery. Use of topical TXA in surgery suggests similar hemostatic efficacy and potentially improved safety as compared with intravenous TXA. For spinal surgery, the literature on topical TXA is sparse but promising, warranting further clinical investigation and consideration as a clinical option in cases with

  3. Current use of navigation system in ACL surgery: a historical review.

    Science.gov (United States)

    Zaffagnini, S; Urrizola, F; Signorelli, C; Grassi, A; Di Sarsina, T Roberti; Lucidi, G A; Marcheggiani Muccioli, G M; Bonanzinga, T; Marcacci, M

    2016-11-01

    The present review aims to analyse the available literature regarding the use of navigation systems in ACL reconstructive surgery underling the evolution during the years. A research of indexed scientific papers was performed on PubMed and Cochrane Library database. The research was performed in December 2015 with no publication year restriction. Only English-written papers and related to the terms ACL, NAVIGATION, CAOS and CAS were considered. Two reviewers independently selected only those manuscripts that presented at least the application of navigation system for ACL reconstructive surgery. One hundred and forty-six of 394 articles were finally selected. In this analysis, it was possible to review the main uses of navigation system in ACL surgery including tunnel positioning for primary and revision surgery and kinematic assessment of knee laxity before and after different surgical procedures. In the early years, until 2006, navigation system was mainly used to improve tunnel positioning, but since the last decade, this tool has been principally used for kinematics evaluation. Increased accuracy of tunnel placement was observed using navigation surgery, especially, regarding femoral, 42 of 146 articles used navigation to guide tunnel positioning. During the following years, 82 of 146 articles have used navigation system to evaluate intraoperative knee kinematic. In particular, the importance of controlling rotatory laxity to achieve better surgical outcomes has been underlined. Several applications have been described and despite the contribution of navigation systems, its potential uses and theoretical advantages, there are still controversies about its clinical benefit. The present papers summarize the most relevant studies that have used navigation system in ACL reconstruction. In particular, the analysis identified four main applications of the navigation systems during ACL reconstructive surgery have been identified: (1) technical assistance for tunnel

  4. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Science.gov (United States)

    2011-03-21

    ...] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition for Review... an advisory committee Ethicon Endo- Surgery Inc.'s (EES's), petition for review of the Agency's... Foreman, FDA, CDRH, to Ken Charak, Ethicon Endo-Surgery, Inc., containing the order denying approval of...

  5. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study.

    Directory of Open Access Journals (Sweden)

    Liang Li

    Full Text Available To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery.In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems.The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons.The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.

  6. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study

    Science.gov (United States)

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365

  7. Bitot’s Spots following Bariatric Surgery: An Ocular Manifestation of a Systemic Disease

    Directory of Open Access Journals (Sweden)

    Amanda R. Crum

    2017-12-01

    Full Text Available Background: To present a case of ocular complications from vitamin A deficiency following bariatric surgery. Case Report: A 41-year-old woman presented with symptoms of dryness and diminished night vision. Examination revealed corneal punctate staining, keratinization of the conjunctiva, and multiple mid-peripheral white lesions at the level of the retinal pigment epithelium. Given the patient’s history of bariatric surgery, anemia, and vitamin D deficiency, further investigation into micronutrient levels was performed and indicated a severe vitamin A deficiency. Oral vitamin A supplementation resulted in the complete resolution of her symptoms within two months. Conclusions: Nutritional deficiencies following bariatric surgery are common and can be disruptive to normal systemic health and visual function. Given that the number of patients pursuing bariatric surgery for weight loss management has increased over the past 50 years, eye care professionals should be aware of the ophthalmic manifestations associated with micronutrient deficiency.

  8. Preoperative multidisciplinary program for bariatric surgery: a proposal for the Brazilian Public Health System

    Directory of Open Access Journals (Sweden)

    Elinton Adami CHAIM

    Full Text Available ABSTRACT BACKGROUND Bariatric surgery has become the gold standard treatment for morbid obesity, but access to surgery remains difficult and low compliance to postoperative follow-up is common. To improve outcomes, enable access and optimize follow-up, we developed a multidisciplinary preoperative approach for bariatric surgery. OBJECTIVE To determine the impact of this program in the outcomes of bariatric surgery in the Brazilian public health system. METHODS A prospective evaluation of the individuals who underwent a preoperative multidisciplinary program for bariatric surgery and comparison of their surgical outcomes with those observed in the prospectively collected historical database of the individuals who underwent surgery before the beginning of the program. RESULTS There were 176 individuals who underwent the multidisciplinary program and 226 who did not. Individuals who underwent the program had significantly lower occurrence of the following variables: hospital stay; wound dehiscence; wound infection; pulmonary complications; anastomotic leaks; pulmonary thromboembolism; sepsis; incisional hernias; eventrations; reoperations; and mortality. Both loss of follow-up and weight loss failure were also significantly lower in the program group. CONCLUSION The adoption of a comprehensive preoperative multidisciplinary approach led to significant improvements in the postoperative outcomes and also in the compliance to the postoperative follow-up. It represents a reproducible and potentially beneficial approach within the context of the Brazilian public health system.

  9. Impact of radioguided occult lesion localization on the correct excision of malignant breast lesions. Effect of histology and tumor size

    International Nuclear Information System (INIS)

    Woll, J.P.P.; Garcia Vicente, A.M.; Gonzalez Garcia, B.; Delgado Portela, M.; Cordero Garcia, J.M.; Pardo Garcia, R.; Molino Trinidad, C.; Soriano Castrejon, A.M.; Cortes Romera, M.

    2011-01-01

    The aim of this study was to evaluate the impact of radioguided occult lesion localization (ROLL) in the correct location and excision of malignant breast lesions, and analyze if these results are affected by the histology and tumor size. A total of 105 patients with occult breast lesions were studied. The mean age was 55 years. An intralesional dose of 18.5 MBq of 99mTc-labeled macroaggregated human albumin (AMA) was administered using stereotaxic mammography or ultrasound. Surgical resection was carried out with the help of a gammadetector probe. In the histological study, disease-free margin was defined by a distance between the tumor lesion and the surgical margin of more than 1 mm. The possible influence of tumor histology and lesion diameter with respect to free/affected margins was analyzed. Correct radiotracer placement was achieved in 100/105 of the cases (95.2%). In the remaining 5 cases (4.8%), radiotracer placement was incorrect, with 2 of them being malignant lesions that were found by macroscopic inspection, and the other 3 having benign pathology. Among the malignant lesions (44 cases), correct placement of the radiotracer was achieved in 42 cases (95.5%). Of these 42 malignant lesions, in which the ROLL was correctly performed, free surgical margins were obtained in 24 cases (57.1%), while the other 18 (42.9%) had infiltrated surgical margins. The most common histological type among the malignant lesions was invasive ductal carcinoma (71.4%). The histological types with an increased frequency of infiltration of surgical margins were invasive and microinvasive cancer (94.4%). All the affected margins were in lesions greater than 10 mm, and the highest incidence was in those between 20 and 30 mm (55.5%). In our experience, the advantages of the ROLL technique are a precise localization of malignant breast lesions (95.5%) and an increased probability of a complete excision with free margins in more than one half of them. Nevertheless, special

  10. [Financing of inpatient orthopaedics and trauma surgery in the 2011 G-DRG System].

    Science.gov (United States)

    Franz, D; Schemmann, F; Roeder, N; Siebert, H; Mahlke, L

    2011-09-01

    The German DRG system forms the basis for billing inpatient hospital services. It includes not only the case groups (G-DRGs), but also copayments. This paper analyses and evaluates the relevant developments of the 2011 G-DRG system for orthopaedics and traumatology from the medical and classificatory perspective. An analysis was performed of relevant diagnoses, medical procedures and G-DRGs in the 2010 and 2011 versions based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). A number of codes for surgical measures have been newly established or modified - above all in foot surgery, arthroscopic surgery and wound surgery. Here, the identification and the correct and performance-based mapping of complex and elaborate scenarios was again the focus of the restructuring of the G-DRG system. The G-DRG structure in orthopaedics and traumatology is changed, especially for polytraumata. The allocation of common cases with a standardized treatment pattern appears to be appropriate and the reimbursement adequate. For the less common and more complex cases the 2011 G-DRG system still shows need for further modification (e.g. polytraumata, joint replacement, spine surgery). The proper integration of the modified OPS classification for foot surgery to the appropriate G-DRGs will be essential to maintain the high quality of the reimbursement structure for the future.

  11. A spatial registration method for navigation system combining O-arm with spinal surgery robot

    Science.gov (United States)

    Bai, H.; Song, G. L.; Zhao, Y. W.; Liu, X. Z.; Jiang, Y. X.

    2018-05-01

    The minimally invasive surgery in spinal surgery has become increasingly popular in recent years as it reduces the chances of complications during post-operation. However, the procedure of spinal surgery is complicated and the surgical vision of minimally invasive surgery is limited. In order to increase the quality of percutaneous pedicle screw placement, the O-arm that is a mobile intraoperative imaging system is used to assist surgery. The robot navigation system combined with O-arm is also increasing, with the extensive use of O-arm. One of the major problems in the surgical navigation system is to associate the patient space with the intra-operation image space. This study proposes a spatial registration method of spinal surgical robot navigation system, which uses the O-arm to scan a calibration phantom with metal calibration spheres. First, the metal artifacts were reduced in the CT slices and then the circles in the images based on the moments invariant could be identified. Further, the position of the calibration sphere in the image space was obtained. Moreover, the registration matrix is obtained based on the ICP algorithm. Finally, the position error is calculated to verify the feasibility and accuracy of the registration method.

  12. The da Vinci telerobotic surgical system: the virtual operative field and telepresence surgery.

    Science.gov (United States)

    Ballantyne, Garth H; Moll, Fred

    2003-12-01

    The United States Department of Defense developed the telepresence surgery concept to meet battlefield demands. The da Vinci telerobotic surgery system evolved from these efforts. In this article, the authors describe the components of the da Vinci system and explain how the surgeon sits at a computer console, views a three-dimensional virtual operative field, and performs the operation by controlling robotic arms that hold the stereoscopic video telescope and surgical instruments that simulate hand motions with seven degrees of freedom. The three-dimensional imaging and handlike motions of the system facilitate advanced minimally invasive thoracic, cardiac, and abdominal procedures. da Vinci has recently released a second generation of telerobots with four arms and will continue to meet the evolving challenges of surgery.

  13. A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

    Science.gov (United States)

    Xu, Xinghua; Zheng, Yi; Yao, Shujing; Sun, Guochen; Xu, Bainan; Chen, Xiaolei

    2018-01-01

    With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. A multimodal HMD system, mainly consisted of a HMD with two built-in displays, an action camera, and a laptop computer displaying reconstructed medical images, was developed to assist neuroendoscopic surgery. With this intensively integrated system, the neurosurgeon could freely switch between endoscopic image, three-dimensional (3D) reconstructed virtual endoscopy images, and surrounding environment images. Using a leap motion controller, the neurosurgeon could adjust or rotate the 3D virtual endoscopic images at a distance to better understand the positional relation between lesions and normal tissues at will. A total of 21 consecutive patients with ventricular system diseases underwent neuroendoscopic surgery with the aid of this system. All operations were accomplished successfully, and no system-related complications occurred. The HMD was comfortable to wear and easy to operate. Screen resolution of the HMD was high enough for the neurosurgeon to operate carefully. With the system, the neurosurgeon might get a better comprehension on lesions by freely switching among images of different modalities. The system had a steep learning curve, which meant a quick increment of skill with it. Compared with commercially available surgical assistant instruments, this system was relatively low-cost. The multimodal HMD system is feasible, practical, helpful, and relatively cost efficient in neuroendoscopic surgery.

  14. [First experience in the thyroid and parathyroid surgery using the da Vinci® system].

    Science.gov (United States)

    Al Kadah, B; Siemer, S; Schick, B

    2014-01-01

    Endoscopic surgery for the treatment of thyroid and parathyroid pathologies is gaining increasing attention. The da Vinci® system has been already widely used in different fields of medicine including recently thyroid and parathyroid surgery. Herein we report our first experiences in endoscopic surgery of thyroid and parathyroid pathologies using the da Vinci® system. 8 patients presenting with struma nodosa in 6 cases and parathyroid adenomas in 2 cases have been treated using the da Vinci® system at the ENT department of Homburg/Saar University. The skin incision to introduce the instruments with the da Vinci® system were axilar or at the lateral segment of the clavicle. The neurovascular structures like inferior laryngeal nerve as well as the pathologies were clearly 3-dimensional visualized in all 8 cases. No paralysis of the vocal cord was observed. All patients had in histological examination a benign pathology. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci® system and offers an excellent, intraoperative, 3-dimensional visualization of the neurovascular structures. Additionally the da Vinci® system enables skin incisions within considerable distance from the thyroid and parathyroid gland. © Georg Thieme Verlag KG Stuttgart · New York.

  15. A VidEo-Based Intelligent Recognition and Decision System for the Phacoemulsification Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Shu Tian

    2015-01-01

    Full Text Available The phacoemulsification surgery is one of the most advanced surgeries to treat cataract. However, the conventional surgeries are always with low automatic level of operation and over reliance on the ability of surgeons. Alternatively, one imaginative scene is to use video processing and pattern recognition technologies to automatically detect the cataract grade and intelligently control the release of the ultrasonic energy while operating. Unlike cataract grading in the diagnosis system with static images, complicated background, unexpected noise, and varied information are always introduced in dynamic videos of the surgery. Here we develop a VidEo-Based Intelligent Recognitionand Decision (VEBIRD system, which breaks new ground by providing a generic framework for automatically tracking the operation process and classifying the cataract grade in microscope videos of the phacoemulsification cataract surgery. VEBIRD comprises a robust eye (iris detector with randomized Hough transform to precisely locate the eye in the noise background, an effective probe tracker with Tracking-Learning-Detection to thereafter track the operation probe in the dynamic process, and an intelligent decider with discriminative learning to finally recognize the cataract grade in the complicated video. Experiments with a variety of real microscope videos of phacoemulsification verify VEBIRD’s effectiveness.

  16. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

    Science.gov (United States)

    López-Mir, F.; Naranjo, V.; Fuertes, J. J.; Alcañiz, M.; Bueno, J.; Pareja, E.

    2013-01-01

    Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment) were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery. PMID:24236293

  17. Development and application of stent-based image guided navigation system for oral and maxillofacial surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woo Jin; Kim, Dae Seung [Interdisciplinary Program in Radiation Applied Life Science, Dental Research Institute and BK21, College of Medicine, Seoul National University, Seoul (Korea, Republic of); Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul; Heo, Min Suk; Huh, Kyung Hoe; Kim, Myung Jin; Lee, Jee Ho [Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2009-09-15

    The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. We devised a patient-specific stent for patient-to-image registration and navigation. Three dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. The accuracy over 8 anatomical landmarks showed an overall mean of 0.56 {+-} 0.16 mm. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  18. Design and Validation of an Augmented Reality System for Laparoscopic Surgery in a Real Environment

    Directory of Open Access Journals (Sweden)

    F. López-Mir

    2013-01-01

    Full Text Available Purpose. This work presents the protocol carried out in the development and validation of an augmented reality system which was installed in an operating theatre to help surgeons with trocar placement during laparoscopic surgery. The purpose of this validation is to demonstrate the improvements that this system can provide to the field of medicine, particularly surgery. Method. Two experiments that were noninvasive for both the patient and the surgeon were designed. In one of these experiments the augmented reality system was used, the other one was the control experiment, and the system was not used. The type of operation selected for all cases was a cholecystectomy due to the low degree of complexity and complications before, during, and after the surgery. The technique used in the placement of trocars was the French technique, but the results can be extrapolated to any other technique and operation. Results and Conclusion. Four clinicians and ninety-six measurements obtained of twenty-four patients (randomly assigned in each experiment were involved in these experiments. The final results show an improvement in accuracy and variability of 33% and 63%, respectively, in comparison to traditional methods, demonstrating that the use of an augmented reality system offers advantages for trocar placement in laparoscopic surgery.

  19. Development and application of stent-based image guided navigation system for oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Lee, Woo Jin; Kim, Dae Seung; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul; Heo, Min Suk; Huh, Kyung Hoe; Kim, Myung Jin; Lee, Jee Ho

    2009-01-01

    The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. We devised a patient-specific stent for patient-to-image registration and navigation. Three dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. The accuracy over 8 anatomical landmarks showed an overall mean of 0.56 ± 0.16 mm. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  20. Evaluation on usefulness of stereotactic radio surgery using Fraxion system

    International Nuclear Information System (INIS)

    Kim, Tae Won; Park, Kwang Woo; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoon Jin; Kim, Sei Joon; Kim, Jong Dae; Shin, Dong Bong

    2014-01-01

    We evaluated the usefulness of Fraxion system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while Fraxion system was used for the other 3 patients (group 2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when Fraxion system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using Fraxion system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when sthermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using Fraxion system showed only 1.9%. All percentage were calculated with respect to average value. Using Fraxion system including mouthpiece, Fraxion frame, front piece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system

  1. Evaluation on usefulness of stereotactic radio surgery using Fraxion system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Won; Park, Kwang Woo; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoon Jin; Kim, Sei Joon; Kim, Jong Dae; Shin, Dong Bong [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2014-12-15

    We evaluated the usefulness of Fraxion system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while Fraxion system was used for the other 3 patients (group 2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when Fraxion system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using Fraxion system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when sthermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using Fraxion system showed only 1.9%. All percentage were calculated with respect to average value. Using Fraxion system including mouthpiece, Fraxion frame, front piece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

  2. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

    Science.gov (United States)

    Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo

    2016-01-01

    The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (Psystem also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.

  3. Apport de la biopsie radioguidée dans le diagnostic histopathologique des tumeurs de l'enfant: expérience de l'Hôpital d'Enfant de Rabat

    Science.gov (United States)

    El Ochi, Mohamed Réda; Bellarbi, Salma; Rouas, Lamiae; Lamalmi, Najat; Malihy, Abderrahmane; Alhamany, Zaitouna; Cherradi, Nadia

    2015-01-01

    La biopsie radioguidée constitue une alternative à la biopsie chirurgicale invasive et à la cytologie pour le diagnostic des tumeurs pédiatriques. L'intérêt de notre étude est d’évaluer la valeur diagnostique des biopsies radioguidées examinées au laboratoire d'anatomopathologie de l'hôpital d'Enfants de Rabat (HER). L’étude a porté sur 78 biopsies radioguidées recueillies dans notre laboratoire entre janvier 2008 et décembre 2011. l’âge moyen des patients était de 5 ans et 10 mois avec une prédominance masculine (65,4%). La tumeur était abdominale dans 80% des cas, thoracique dans 15% cas, thoracique et abdominale dans 2,5% et sacrée dans 1,2%. Les biopsies étaient écho-guidées dans 90% des cas et scannoguidées dans 10% des cas. Le diagnostic histopathologique était posé dans 89% des cas. L'immuno-histochimie a été indiquée dans 35% des cas. Les diagnostics les plus fréquents étaient: tumeurs neuroblastiques (42 cas), lymphomes non hodgkiniens (10 cas), rhabdomyosarcomes (6 cas), autres (sarcome d'Ewing, néphroblastomes, tumeur myofibroblastique inflammatoire, maladies de Hodgkin, leucémie aiguë, hépatoblastome et ostéosarcome). Dans notre série, la biopsie radioguidée a permis un diagnostic histopathologique certain dans 89% des cas. Elle nécessite une étroite collaboration entre clinicien, radiologue et anatomopathologiste pour discuter son indication, afin de diminuer le nombre de biopsies peu ou non représentatives. PMID:26587165

  4. Important issues for perioperative systemic antimicrobial prophylaxis in surgery

    NARCIS (Netherlands)

    Sinha, Bhanu; van Assen, Sander; Friedrich, Alexander W.

    PURPOSE OF REVIEW: Prevention of surgical site infections is a key issue to patient safety and the success of surgical interventions. Systemic antimicrobial prophylaxis is one important component of a perioperative infection prevention bundle. This review focuses on selected recent developments and

  5. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    Science.gov (United States)

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  6. Age and other perioperative risk factors for postoperative systemic inflammatory response syndrome after cardiac surgery

    NARCIS (Netherlands)

    Dieleman, J. M.; Peelen, L. M.; Coulson, T. G.; Tran, L.; Reid, C. M.; Smith, Jennifer A.; Myles, P. S.; Pilcher, C.D.

    2017-01-01

    Background The inflammatory response to surgery varies considerably between individual patients. Age might be a substantial factor in this variability. Our objective was to examine the association of patient age and other potential risk factors with the occurrence of a postoperative systemic

  7. A benefit-risk review of systemic haemostatic agents - Part 1 : In major surgery

    NARCIS (Netherlands)

    Fraser, Ian S.; Porte, Robert J.; Kouides, Peter A.; Lukes, Andrea S.

    2008-01-01

    Systemic haemostatic agents play an important role in the management of blood loss during major surgery where significant blood loss is likely and their use has increased in recent times as a consequence of demand for blood products outstripping supply and the risks associated with transfusions.

  8. Comparison of the cable pin system with conventional open surgery for transverse patella fractures.

    Science.gov (United States)

    Mao, Ningfang; Liu, Deding; Ni, Haijian; Tang, Hao; Zhang, Qiulin

    2013-07-01

    The cable pin system is an effective device for fixation of transverse patella fractures. However, whether this device provides superior results using a minimally invasive technique instead of conventional open surgery using the K wire tension band method is unclear. We asked whether a minimally invasive technique would be associated with (1) increased operative time; (2) reduced postoperative pain; (3) faster recovery of ROM; (4) higher knee scores; and (5) reduced complications. Forty patients with displaced transverse fractures of the patella participated in this prospective, randomized, controlled trial. Twenty of these patients underwent a minimally invasive technique and the others had conventional open surgery using K wires. Some data for six of the 20 patients who underwent the minimally invasive technique were published in an earlier prospective, observational trial. At postoperative intervals of 1, 3, 6, 12, and 24 months, pain was measured by VAS scores, active flexion and extension of the knee were measured in degrees by goniometry, and knee function was evaluated using the Böstman clinical grading scale. Operative time was longer in the minimally invasive surgery group (54.3 ± 9.8 minutes versus 48.5 ± 6.1 minutes). Pain scores were better (lower) in the minimally invasive surgery group at 1 and 3 months but not at 6 months. Early flexion, ultimate flexion, and knee scores from 3 to 24 months, likewise, were better in the minimally invasive surgery group. Complications mostly related to symptomatic hardware were less common in the minimally invasive surgery group. The minimally invasive technique is superior to conventional open surgery using K wires in terms of less early postoperative pain, better mobility angles of the injured knee, higher functional score of the injured knee, and decreased incidence of complications. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  9. Development of the robot system to assist CT-guided brain surgery

    International Nuclear Information System (INIS)

    Koyama, H.; Funakubo, H.; Komeda, T.; Uchida, T.; Takakura, K.

    1999-01-01

    The robot technology was introduced into the stereotactic neurosurgery for application to biopsy, blind surgery, and functional neurosurgery. The authors have developed a newly designed the robot system to assist CT-guided brain surgery, designed to allow a biopsy needle to reach the targget such as a cerebral tumor within a brain automatically on the basis of the X,Y, and Z coordinates obtained by CT scanner. In this paper we describe construction of the robot, the control of the robot by CT image, robot simulation, and investigated a phantom experiment using CT image. (author)

  10. The role of surgery in primary central nervous system lymphomas

    Directory of Open Access Journals (Sweden)

    Juan Francisco Villalonga

    Full Text Available ABSTRACT Background Primary central nervous system lymphomas (PCNSL are infrequent. The traditional treatment of choice is chemotherapy. Complete resections have generally not been recommended, because of the risk of permanent central nervous system deficits with no proven improvement in survival. The aim of the current study was to compare survival among patients with PCNSL who underwent biopsy versus surgical resection. Methods A retrospective study was conducted on 50 patients with a confirmed diagnosis of PCNSL treated at our center from January 1994 to July 2015. Results Patients in the resection group exhibited significantly longer median survival time, relative to the biopsy group, surviving a median 31 months versus 14.5 months; p = 0.016. Conclusions In our series, patients who had surgical resection of their tumor survived a median 16.5 months longer than patients who underwent biopsy alone.

  11. Using HFACS-Healthcare to Identify Systemic Vulnerabilities During Surgery.

    Science.gov (United States)

    Cohen, Tara N; Francis, Sarah E; Wiegmann, Douglas A; Shappell, Scott A; Gewertz, Bruce L

    2018-03-01

    The Human Factors Analysis and Classification System for Healthcare (HFACS-Healthcare) was used to classify surgical near miss events reported via a hospital's event reporting system over the course of 1 year. Two trained analysts identified causal factors within each event narrative and subsequently categorized the events using HFACS-Healthcare. Of 910 original events, 592 could be analyzed further using HFACS-Healthcare, resulting in the identification of 726 causal factors. Most issues (n = 436, 60.00%) involved preconditions for unsafe acts, followed by unsafe acts (n = 257, 35.39%), organizational influences (n = 27, 3.72%), and supervisory factors (n = 6, 0.82%). These findings go beyond the traditional methods of trending incident data that typically focus on documenting the frequency of their occurrence. Analyzing near misses based on their underlying contributing human factors affords a greater opportunity to develop process improvements to reduce reoccurrence and better provide patient safety approaches.

  12. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  13. A highly articulated robotic surgical system for minimally invasive surgery.

    Science.gov (United States)

    Ota, Takeyoshi; Degani, Amir; Schwartzman, David; Zubiate, Brett; McGarvey, Jeremy; Choset, Howie; Zenati, Marco A

    2009-04-01

    We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

  14. [ENT and head and neck surgery in the German DRG system 2007].

    Science.gov (United States)

    Franz, D; Roeder, N; Hörmann, K; Alberty, J

    2007-07-01

    The German DRG system has been further developed into version 2007. For ENT and head and neck surgery, significant changes in the coding of diagnoses and medical operations as well as in the the DRG structure have been made. New ICD codes for sleep apnoea and acquired tracheal stenosis have been implemented. Surgery on the acoustic meatus, removal of auricle hyaline cartilage for transplantation (e. g. rhinosurgery) and tonsillotomy have been coded in the 2007 version. In addition, the DRG structure has been improved. Case allocation of more than one significant operation has been established. The G-DRG system has gained in complexity. High demands are made on the coding of complex cases, whereas standard cases require mostly only one specific diagnosis and one specific OPS code. The quality of case allocation for ENT patients within the G-DRG system has been improved. Nevertheless, further adjustments of the G-DRG system are necessary.

  15. Tailored patient information using a database system: Increasing patient compliance in a day surgery setting

    DEFF Research Database (Denmark)

    Grode, Jesper Nicolai Riis; Grode, Louise; Steinsøe, Ulla

    rehabilitation. The hospital is responsible of providing the patients with accurate information enabling the patient to prepare for surgery. Often patients are overloaded with uncoordinated information, letters and leaflets. The contribution of this project is a database system enabling health professionals...... to empower patients through tailored individualized information. Performing 6500 operations per year at our Day Surgery Centre, health professionals need a computer based system to create individualized information material. Health professionals must be able to adapt the information material quickly...... was established to support these requirements. A relational database system holds all information pieces in a granular, structured form. Each individual piece of information can be joined with other pieces thus supporting the tailoring of information. A web service layer caters for integration with output systems...

  16. A Panoramic Wireless Endoscope System Design for the Application of Minimally Invasive Surgery

    Directory of Open Access Journals (Sweden)

    Chun-Hsiang Peng

    2014-05-01

    Full Text Available Minimally Invasive Surgery (MIS is the current trend in surgery. Compared to traditional surgery, MIS can substantially decrease recovery time and expenses needed by patients after surgeries, reduce pain during surgical procedures, and is highly regarded by physicians and patients. An endoscope is widely used in the diagnosis and treatments of various medical disciplines, such as hysteroscopy, laparoscopy, and colonoscopy, and have been adopted by many branches of medicine. However, the limited image field of MIS is often the most difficult obstacles faced by surgeons and medical students, especially to less experienced physicians and difficult surgical procedures; the limited field of view of endoscopic imaging does not provide a whole picture of the surgery area, making the procedures difficult and full of uncertainty. In light of this problem, we proposed a "Panoramic Wireless Endoscope System design", hoping to provide physicians with a wide field of view of the endoscopic image. We combine images captured from two parallel-mounted endoscope lenses into a single, wide-angle image, giving physicians a wider field of view and easier access to the surgical area. In addition, we developed a wireless transmission system so the image can be transmitted to various display platforms, eliminating the needs for excessive cabling on surgical tools and enable physicians to better operate on the patient. Finally, our system allows surgical assistants a better view of the operation process, and enables other physicians and nurses to remotely observe the process. Our experiment results have shown that we can increase the image to 152% of its original size. We used the PandaBoard ES platform with an ARM9 processor and 1G of onboard RAM, and continuously implementing animal trials to verify the reliability of our system.

  17. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  18. Tourniquet-induced systemic inflammatory response in extremity surgery.

    LENUS (Irish Health Repository)

    Wakai, A

    2012-02-03

    BACKGROUND: Tourniquet-induced reperfusion injury in animals produces significant systemic inflammatory effects. This study investigated whether a biologic response occurs in a clinically relevant model of tourniquet-induced reperfusion injury. METHODS: Patients undergoing elective knee arthroscopy were prospectively randomized into controls (no tourniquet) and subjects (tourniquet-controlled). The effects of tourniquet-induced reperfusion on monocyte activation state, neutrophil activation state, and transendothelial migration (TEM) were studied. Changes in the cytokines implicated in reperfusion injury, tumor necrosis factor-alpha, interleukin (IL)-1beta, and IL-10 were also determined. RESULTS: After 15 minutes of reperfusion, neutrophil and monocyte activation were significantly increased. Pretreatment of neutrophils with pooled subject (ischemia-primed) plasma significantly increased TEM. In contrast, TEM was not significantly altered by ischemia-primed plasma pretreatment of the endothelial monolayer. Significant elevation of tumor necrosis factor-alpha and IL-1beta were observed in subjects compared with controls after 15 minutes of reperfusion. There was no significant difference in serum IL-10 levels between the groups at all the time points studied. CONCLUSION: These results indicate a transient neutrophil and monocyte activation after tourniquet-ischemia that translates into enhanced neutrophil transendothelial migration with potential for tissue injury.

  19. A novel augmented reality system for displaying inferior alveolar nerve bundles in maxillofacial surgery.

    Science.gov (United States)

    Zhu, Ming; Liu, Fei; Chai, Gang; Pan, Jun J; Jiang, Taoran; Lin, Li; Xin, Yu; Zhang, Yan; Li, Qingfeng

    2017-02-15

    Augmented reality systems can combine virtual images with a real environment to ensure accurate surgery with lower risk. This study aimed to develop a novel registration and tracking technique to establish a navigation system based on augmented reality for maxillofacial surgery. Specifically, a virtual image is reconstructed from CT data using 3D software. The real environment is tracked by the augmented reality (AR) software. The novel registration strategy that we created uses an occlusal splint compounded with a fiducial marker (OSM) to establish a relationship between the virtual image and the real object. After the fiducial marker is recognized, the virtual image is superimposed onto the real environment, forming the "integrated image" on semi-transparent glass. Via the registration process, the integral image, which combines the virtual image with the real scene, is successfully presented on the semi-transparent helmet. The position error of this navigation system is 0.96 ± 0.51 mm. This augmented reality system was applied in the clinic and good surgical outcomes were obtained. The augmented reality system that we established for maxillofacial surgery has the advantages of easy manipulation and high accuracy, which can improve surgical outcomes. Thus, this system exhibits significant potential in clinical applications.

  20. Preoperative renin-angiotensin system inhibitors protect renal function in aging patients undergoing cardiac surgery.

    Science.gov (United States)

    Barodka, Viachaslau; Silvestry, Scott; Zhao, Ning; Jiao, Xiangyin; Whellan, David J; Diehl, James; Sun, Jian-Zhong

    2011-05-15

    Renal failure (RF) represents a major postoperative complication for elderly patients undergoing cardiac surgery. This observational cohort study examines effects of preoperative use of renin-angiotensin system (RAS) inhibitors on postoperative renal failure in aging patients undergoing cardiac surgery. We retrospectively analyzed a cohort of 1287 patients who underwent cardiac surgery at this institution (2003-2007). The patients included were ≥65 years old, scheduled for elective cardiac surgery, and without preexisting RF (defined by the criteria of the Society of Thoracic Surgeons as described in Method). Of all patients evaluated, 346 patients met the inclusion criteria and were divided into two groups: using (n = 122) or not using (n = 224) preoperative RAS inhibitors. A comparison of the two groups showed no significant differences in baseline parameters, including creatinine clearance, body mass index, history of diabetes and smoking, preoperative medicines (except that more patients with RAS inhibitors had a history of hypertension or congestive heart failure, fewer RAS inhibitor patients had chronic lung disease), in intraoperative perfusion and aortic cross-clamp time, and in postoperative complications and 30-d mortality. Multivariate logistic regression analysis demonstrated, however, that preoperative RAS inhibitors significantly and independently reduced the incidence of postoperative RF in the patients undergoing cardiac surgery compared with those not taking RAS inhibitors: 1.6% versus 7.6%, yielding an odds ratio of 0.19 (95 % CI 0.04-0.84, P = 0.029). Preoperative RAS inhibitors may have significant renoprotective effects for aging patients undergoing elective cardiac surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Image-guided stereotactic surgery using ultrasonography and reconstructive three-dimensional CT-imaging system

    International Nuclear Information System (INIS)

    Kawamura, Hirotsune; Iseki, Hiroshi; Umezawa, Yoshihiro

    1991-01-01

    A new simulation and navigation system utilizing three-dimensional CT images has been developed for image-guided stereotactic surgery. Preoperative CT images are not always useful in predicting the intraoperative location of lesions, for cerebral lesions are easily displaced or distorted by gravity, brain retraction, and/or CSF aspiration during operative procedure. This new system, however, has the advantage that the intraoperative locations of intracranial lesions or the anatomical structures of the brain can be precisely confirmed during stereotactic surgery. Serial CT images were obtained from a patient whose head had been fixed to the ISEKI CT-guided stereotactic frame. The data of serial CT images were saved on a floppy disc and then transferred to the work station (IRIS) using the off line. In order to find the best approach angle for ultrasound-guided stereotactic surgery, three-dimenstional CT images were reconstructed using the work station. The site of the craniotomy or the angle of the trajectory of the ultrasound probe was measured preoperatively based on the three-dimensional CT images. Then, in the operating room, the patient's head was fixed to the ISEKI frame with the subframe at the same position as before according to the measurement of the CT images. In a case of cystic glioma, the predicable ultrasonograms from three-dimensional reconstructive CT images were ascertained to correspond well to the actual ultrasound images during ultrasound-guided stereotactic surgery. Therefore, the new simulation and navigation system can be judged to be a powerful operative supporting modality for correcting the locations of cerebral lesions; it allows one to perform stereotactic surgery more accurately and less invasively. (author)

  2. The Application of Three-Dimensional Surface Imaging System in Plastic and Reconstructive Surgery.

    Science.gov (United States)

    Li, Yanqi; Yang, Xin; Li, Dong

    2016-02-01

    Three-dimensional (3D) surface imaging system has gained popularity worldwide in clinical application. Unlike computed tomography and magnetic resonance imaging, it has the ability to capture 3D images with both shape and texture information. This feature has made it quite useful for plastic surgeons. This review article is mainly focusing on demonstrating the current status and analyzing the future of the application of 3D surface imaging systems in plastic and reconstructive surgery.Currently, 3D surface imaging system is mainly used in plastic and reconstructive surgery to help improve the reliability of surgical planning and assessing surgical outcome objectively. There have already been reports of its using on plastic and reconstructive surgery from head to toe. Studies on facial aging process, online applications development, and so on, have also been done through the use of 3D surface imaging system.Because different types of 3D surface imaging devices have their own advantages and disadvantages, a basic knowledge of their features is required and careful thought should be taken to choose the one that best fits a surgeon's demand.In the future, by integrating with other imaging tools and the 3D printing technology, 3D surface imaging system will play an important role in individualized surgical planning, implants production, meticulous surgical simulation, operative techniques training, and patient education.

  3. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...... affect the overall latency. To measure the photon-to-photon latency, we used a microcontroller to determine the time between the activation of a lightemitting diode in front of the endoscopic camera and the corresponding increase in intensity of the surgeon's display as measured by a phototransistor...

  4. [Severity of disease scoring systems and mortality after non-cardiac surgery].

    Science.gov (United States)

    Reis, Pedro Videira; Sousa, Gabriela; Lopes, Ana Martins; Costa, Ana Vera; Santos, Alice; Abelha, Fernando José

    2018-04-05

    Mortality after surgery is frequent and severity of disease scoring systems are used for prediction. Our aim was to evaluate predictors for mortality after non-cardiac surgery. Adult patients admitted at our surgical intensive care unit between January 2006 and July 2013 was included. Univariate analysis was carried using Mann-Whitney, Chi-square or Fisher's exact test. Logistic regression was performed to assess independent factors with calculation of odds ratio and 95% confidence interval (95% CI). 4398 patients were included. Mortality was 1.4% in surgical intensive care unit and 7.4% during hospital stay. Independent predictors of mortality in surgical intensive care unit were APACHE II (OR=1.24); emergent surgery (OR=4.10), serum sodium (OR=1.06) and FiO 2 at admission (OR=14.31). Serum bicarbonate at admission (OR=0.89) was considered a protective factor. Independent predictors of hospital mortality were age (OR=1.02), APACHE II (OR=1.09), emergency surgery (OR=1.82), high-risk surgery (OR=1.61), FiO 2 at admission (OR=1.02), postoperative acute renal failure (OR=1.96), heart rate (OR=1.01) and serum sodium (OR=1.04). Dying patients had higher scores in severity of disease scoring systems and longer surgical intensive care unit stay. Some factors influenced both surgical intensive care unit and hospital mortality. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. Robotic Gastric Bypass Surgery in the Swiss Health Care System: Analysis of Hospital Costs and Reimbursement.

    Science.gov (United States)

    Hagen, Monika E; Rohner, Peter; Jung, Minoa K; Amirghasemi, Nicolas; Buchs, Nicolas C; Fakhro, Jassim; Buehler, Leo; Morel, Philippe

    2017-08-01

    Robotic technology shows some promising early outcomes indicating potentially improved outcomes particularly for challenging bariatric procedures. Still, health care providers face significant clinical and economic challenges when introducing innovations. Prospectively derived administrative cost data of patients who were coded with a primary diagnosis of obesity (ICD-10 code E.66.X), a procedure of gastric bypass surgery (CHOP code 44.3), and a robotic identifier (CHOP codes 00.90.50 or 00.39) during the years 2012 to 2015 was analyzed and compared to the triggered reimbursement for this patient cohort. A total of 348 patients were identified. The mean number of diagnoses was 2.7 and the mean length of stay was 5.9 days. The overall mean cost per patients was Swiss Francs (CHF) from 2012 to 2014 that was 21,527, with a mean reimbursement of CHF 24,917. Cost of the surgery in 2015 was comparable to the previous years with CHF 22,550.0 (p = 0.6618), but reimbursement decreased significantly to CHF 20,499.0 (0.0001). The average cost for robotic gastric bypass surgery fell well below the average reimbursement within the Swiss DRG system between 2012 and 2014, and this robotic procedure was a DRG winner for that period. However, the Swiss DRG system has matured over the years with a significant decrease resulting in a deficit for robotic gastric bypass surgery in 2015. This stipulates a discussion as to how health care providers should continue offering robotic gastric bypass surgery, particularly in the light of developing clinical evidence.

  6. AN EFFICIENT SELF-UPDATING FACE RECOGNITION SYSTEM FOR PLASTIC SURGERY FACE

    Directory of Open Access Journals (Sweden)

    A. Devi

    2016-08-01

    Full Text Available Facial recognition system is fundamental a computer application for the automatic identification of a person through a digitized image or a video source. The major cause for the overall poor performance is related to the transformations in appearance of the user based on the aspects akin to ageing, beard growth, sun-tan etc. In order to overcome the above drawback, Self-update process has been developed in which, the system learns the biometric attributes of the user every time the user interacts with the system and the information gets updated automatically. The procedures of Plastic surgery yield a skilled and endurable means of enhancing the facial appearance by means of correcting the anomalies in the feature and then treating the facial skin with the aim of getting a youthful look. When plastic surgery is performed on an individual, the features of the face undergo reconstruction either locally or globally. But, the changes which are introduced new by plastic surgery remain hard to get modeled by the available face recognition systems and they deteriorate the performances of the face recognition algorithm. Hence the Facial plastic surgery produces changes in the facial features to larger extent and thereby creates a significant challenge to the face recognition system. This work introduces a fresh Multimodal Biometric approach making use of novel approaches to boost the rate of recognition and security. The proposed method consists of various processes like Face segmentation using Active Appearance Model (AAM, Face Normalization using Kernel Density Estimate/ Point Distribution Model (KDE-PDM, Feature extraction using Local Gabor XOR Patterns (LGXP and Classification using Independent Component Analysis (ICA. Efficient techniques have been used in each phase of the FRAS in order to obtain improved results.

  7. Simple Scoring System to Predict In-Hospital Mortality After Surgery for Infective Endocarditis.

    Science.gov (United States)

    Gatti, Giuseppe; Perrotti, Andrea; Obadia, Jean-François; Duval, Xavier; Iung, Bernard; Alla, François; Chirouze, Catherine; Selton-Suty, Christine; Hoen, Bruno; Sinagra, Gianfranco; Delahaye, François; Tattevin, Pierre; Le Moing, Vincent; Pappalardo, Aniello; Chocron, Sidney

    2017-07-20

    Aspecific scoring systems are used to predict the risk of death postsurgery in patients with infective endocarditis (IE). The purpose of the present study was both to analyze the risk factors for in-hospital death, which complicates surgery for IE, and to create a mortality risk score based on the results of this analysis. Outcomes of 361 consecutive patients (mean age, 59.1±15.4 years) who had undergone surgery for IE in 8 European centers of cardiac surgery were recorded prospectively, and a risk factor analysis (multivariable logistic regression) for in-hospital death was performed. The discriminatory power of a new predictive scoring system was assessed with the receiver operating characteristic curve analysis. Score validation procedures were carried out. Fifty-six (15.5%) patients died postsurgery. BMI >27 kg/m 2 (odds ratio [OR], 1.79; P =0.049), estimated glomerular filtration rate 55 mm Hg (OR, 1.78; P =0.032), and critical state (OR, 2.37; P =0.017) were independent predictors of in-hospital death. A scoring system was devised to predict in-hospital death postsurgery for IE (area under the receiver operating characteristic curve, 0.780; 95% CI, 0.734-0.822). The score performed better than 5 of 6 scoring systems for in-hospital death after cardiac surgery that were considered. A simple scoring system based on risk factors for in-hospital death was specifically created to predict mortality risk postsurgery in patients with IE. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. [ENT medicine and head and neck surgery in the G-DRG system 2008].

    Science.gov (United States)

    Franz, D; Roeder, N; Hörmann, K; Alberty, J

    2008-09-01

    Further developments in the German DRG system have been incorporated into the 2008 version. For ENT medicine and head and neck surgery significant changes concerning coding of diagnoses, medical procedures and concerning the DRG-structure were made. Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2007 and 2008 based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2008 focussed on the development of DRG structure, DRG validation and codes for medical procedures. The outcome of these changes for German hospitals may vary depending on the range of activities. The G-DRG system has gained in complexity again. High demands are made on correct and complete coding of complex ENT and head and neck surgery cases. Quality of case allocation within the G-DRG system has been improved. For standard cases quality of case allocation is adequate. Nevertheless, further adjustments of the G-DRG system especially for cases with complex neck surgery are necessary.

  9. Efficacy of an Intra-Operative Imaging Software System for Anatomic Anterior Cruciate Ligament Reconstruction Surgery

    Directory of Open Access Journals (Sweden)

    Xudong Zhang

    2012-01-01

    Full Text Available An imaging software system was studied for improving the performance of anatomic anterior cruciate ligament (ACL reconstruction which requires identifying ACL insertion sites for bone tunnel placement. This software predicts and displays the insertion sites based on the literature data and patient-specific bony landmarks. Twenty orthopaedic surgeons performed simulated arthroscopic ACL surgeries on 20 knee specimens, first without and then with the visual guidance by fluoroscopic imaging, and their tunnel entry positions were recorded. The native ACL insertion morphologies of individual specimens were quantified in relation to CT-based bone models and then used to evaluate the software-generated insertion locations. Results suggested that the system was effective in leading surgeons to predetermined locations while the application of averaged insertion morphological information in individual surgeries can be susceptible to inaccuracy and uncertainty. Implications on challenges associated with developing engineering solutions to aid in re-creating or recognizing anatomy in surgical care delivery are discussed.

  10. Cloud-Based Service Information System for Evaluating Quality of Life after Breast Cancer Surgery.

    Directory of Open Access Journals (Sweden)

    Hao-Yun Kao

    Full Text Available Although recent studies have improved understanding of quality of life (QOL outcomes of breast conserving surgery, few have used longitudinal data for more than two time points, and few have examined predictors of QOL over two years. Additionally, the longitudinal data analyses in such studies rarely apply the appropriate statistical methodology to control for censoring and inter-correlations arising from repeated measures obtained from the same patient pool. This study evaluated an internet-based system for measuring longitudinal changes in QOL and developed a cloud-based system for managing patients after breast conserving surgery.This prospective study analyzed 657 breast cancer patients treated at three tertiary academic hospitals. Related hospital personnel such as surgeons and other healthcare professionals were also interviewed to determine the requirements for an effective cloud-based system for surveying QOL in breast cancer patients. All patients completed the SF-36, Quality of Life Questionnaire (QLQ-C30 and its supplementary breast cancer measure (QLQ-BR23 at baseline, 6 months, 1 year, and 2 years postoperatively. The 95% confidence intervals for differences in responsiveness estimates were derived by bootstrap estimation. Scores derived by these instruments were interpreted by generalized estimating equation before and after surgery.All breast cancer surgery patients had significantly improved QLQ-C30 and QLQ-BR23 subscale scores throughout the 2-year follow-up period (p<0.05. During the study period, QOL generally had a negative association with advanced age, high Charlson comorbidity index score, tumor stage III or IV, previous chemotherapy, and long post-operative LOS. Conversely, QOL was positively associated with previous radiotherapy and hormone therapy. Additionally, patients with high scores for preoperative QOL tended to have high scores for QLQ-C30, QLQ-BR23 and SF-36 subscales. Based on the results of usability testing

  11. Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery

    DEFF Research Database (Denmark)

    Jørgensen, Martin Kibsgaard; Kraus, Martin

    2017-01-01

    Minimal latency is important for augmented reality systems and teleoperation interfaces as even small increases in latency can affect user performance. Previously, we have developed an augmented reality system that can overlay stereoscopic video streams with computer graphics in order to improve....... The latency of the da Vinci S surgical system was on average 62 ms. None of the components of our overlay system (separately or combined) significantly affected the latency. However, the latency of the assistant's monitor increased by 14 ms. Passing the video streams through CPU or GPU memory increased...... visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...

  12. Neuronavigation in brain tumor surgery:clinical beta-phase of the Oulu Neuronavigator System

    OpenAIRE

    Schiffbauer, H. (Hagen)

    1999-01-01

    Abstract Interactive image-guided neurosurgery for the resection of brain tumors was developed within the last 10 years at different neurosurgical centers around the world to improve the safety of the surgery and the functional outcome of the patients. Since 1987, the Oulu Neuronavigator System, consisting mainly of a mechanical arm, visualization software, an ultrasound transducer and a computer, was developed at the Neurosurgical Research Unit, University of Oulu, Finland. It was the fir...

  13. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  14. Implementation of Enhanced Recovery After Surgery: a strategy to transform surgical care across a health system.

    Science.gov (United States)

    Gramlich, Leah M; Sheppard, Caroline E; Wasylak, Tracy; Gilmour, Loreen E; Ljungqvist, Olle; Basualdo-Hammond, Carlota; Nelson, Gregg

    2017-05-19

    Enhanced Recovery After Surgery (ERAS) programs have been shown to have a positive impact on outcome. The ERAS care system includes an evidence-based guideline, an implementation program, and an interactive audit system to support practice change. The purpose of this study is to describe the use of the Theoretic Domains Framework (TDF) in changing surgical care and application of the Quality Enhancement Research Initiative (QUERI) model to analyze end-to-end implementation of ERAS in colorectal surgery across multiple sites within a single health system. The ultimate intent of this work is to allow for the development of a model for spread, scale, and sustainability of ERAS in Alberta Health Services (AHS). ERAS for colorectal surgery was implemented at two sites and then spread to four additional sites. The ERAS Interactive Audit System (EIAS) was used to assess compliance with the guidelines, length of stay, readmissions, and complications. Data sources informing knowledge translation included surveys, focus groups, interviews, and other qualitative data sources such as minutes and status updates. The QUERI model and TDF were used to thematically analyze 189 documents with 2188 quotes meeting the inclusion criteria. Data sources were analyzed for barriers or enablers, organized into a framework that included individual to organization impact, and areas of focus for guideline implementation. Compliance with the evidence-based guidelines for ERAS in colorectal surgery at baseline was 40%. Post implementation compliance, consistent with adoption of best practice, improved to 65%. Barriers and enablers were categorized as clinical practice (22%), individual provider (26%), organization (19%), external environment (7%), and patients (25%). In the Alberta context, 26% of barriers and enablers to ERAS implementation occurred at the site and unit levels, with a provider focus 26% of the time, a patient focus 26% of the time, and a system focus 22% of the time. Using the

  15. Experiences from the Architectural Migration of a Joint Replacement Surgery Information System

    Directory of Open Access Journals (Sweden)

    Samuli Niiranen

    2008-01-01

    Full Text Available The goal of this study is to present the experiences gathered from the migration of an existing and deployed joint replacement surgery information system from a classical 2-tier architecture to a 4-tier architecture. These include discussion on the motivation for the migration and on the technical benefits of the chosen technical migration path and an evaluation of user experiences. The results from the analysis of clinical end-user and administrator experiences show an increase in the perceived performance and maintainability of the system and a high level of acceptance for the new system version.

  16. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery

    Directory of Open Access Journals (Sweden)

    Jones JJ

    2016-06-01

    Full Text Available Jason J Jones,1 Jeffrey Chu,2 Jacob Graham,2 Serge Zaluski,3 Guillermo Rocha4 1Jones Eye Clinic, Sioux City, IA, 2Quorum Consulting Inc., San Francisco, CA, USA; 3VISIS, Perpignan, France; 4Ocular Microsurgery & Laser Centre, Brandon, MB, Canada Purpose: The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Methods: Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. Results: The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%–12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France. Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Conclusion: Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity. Keywords: time and motion, provider impact, surgical throughput, IOL

  17. Feasibility of real-time location systems in monitoring recovery after major abdominal surgery.

    Science.gov (United States)

    Dorrell, Robert D; Vermillion, Sarah A; Clark, Clancy J

    2017-12-01

    Early mobilization after major abdominal surgery decreases postoperative complications and length of stay, and has become a key component of enhanced recovery pathways. However, objective measures of patient movement after surgery are limited. Real-time location systems (RTLS), typically used for asset tracking, provide a novel approach to monitoring in-hospital patient activity. The current study investigates the feasibility of using RTLS to objectively track postoperative patient mobilization. The real-time location system employs a meshed network of infrared and RFID sensors and detectors that sample device locations every 3 s resulting in over 1 million data points per day. RTLS tracking was evaluated systematically in three phases: (1) sensitivity and specificity of the tracking device using simulated patient scenarios, (2) retrospective passive movement analysis of patient-linked equipment, and (3) prospective observational analysis of a patient-attached tracking device. RTLS tracking detected a simulated movement out of a room with sensitivity of 91% and specificity 100%. Specificity decreased to 75% if time out of room was less than 3 min. All RTLS-tagged patient-linked equipment was identified for 18 patients, but measurable patient movement associated with equipment was detected for only 2 patients (11%) with 1-8 out-of-room walks per day. Ten patients were prospectively monitored using RTLS badges following major abdominal surgery. Patient movement was recorded using patient diaries, direct observation, and an accelerometer. Sensitivity and specificity of RTLS patient tracking were both 100% in detecting out-of-room ambulation and correlated well with direct observation and patient-reported ambulation. Real-time location systems are a novel technology capable of objectively and accurately monitoring patient movement and provide an innovative approach to promoting early mobilization after surgery.

  18. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    Science.gov (United States)

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  19. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    Science.gov (United States)

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2017-09-01

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  20. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  1. Effects of Topical Phenylephrine HCl 2.5% used before Cataract Surgery on Systemic Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emre Ayıntap

    2011-06-01

    Full Text Available Purpose: To evaluate the effect of topical phenylephrine HCl 2.5% (Mydfrin, used as a fast and effective mydriatic before cataract surgery, on systemic blood pressure. Material and Method: Topical phenylephrine HCl 2.5% was administered 3 times with 5-minute intervals before cataract surgery to 44 eyes of 44 patients. The systemic blood pressure was measured preoperatively and at 15 and 30 minutes. Results: The mean systolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 119.7mmHg, while 15 and 30 minutes later, it was 125.3 mmHg and 121.2 mmHg, respectively. The mean diastolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 75.9 mmHg; 15 and 30 minutes later, it was 76.9 mmHg and 75.3 mmHg, respectively. The increase in systolic blood pressure at 15 and 30 minutes was statistically significant (p=0.003 and p=0.042. The change in diastolic blood pressure was not statistically significant. Discussion: Phenylephrine HCl 2.5%, which is used preoperatively as a fast and effective mydriatic for cataract surgery, can increase the systolic blood pressure. This effect is most significant at 15 minutes and lasts at least 30 minutes. This agent should be used with care in hypertensive patients. (Turk J Ophthalmol 2011; 41: 164-6

  2. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  3. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  4. A novel navigation system for maxillary positioning in orthognathic surgery: Preclinical evaluation.

    Science.gov (United States)

    Lutz, Jean-Christophe; Nicolau, Stéphane; Agnus, Vincent; Bodin, Frédéric; Wilk, Astrid; Bruant-Rodier, Catherine; Rémond, Yves; Soler, Luc

    2015-11-01

    Appropriate positioning of the maxilla is critical in orthognathic surgery. As opposed to splint-based positioning, navigation systems are versatile and appropriate in assessing the vertical dimension. Bulk and disruption to the line of sight are drawbacks of optical navigation systems. Our aim was to develop and assess a novel navigation system based on electromagnetic tracking of the maxilla, including real-time registration of head movements. Since the software interface has proved to greatly influence the accuracy of the procedure, we purposely designed and evaluated an original, user-friendly interface. A sample of 12 surgeons had to navigate the phantom osteotomized maxilla to eight given target positions using the software we have developed. Time and accuracy (translational error and angular error) were compared between a conventional and a navigated session. A questionnaire provided qualitative evaluation. Our system definitely allows a reduction in variability of time and accuracy among different operators. Accuracy was improved in all surgeons (mean terror difference = 1.11 mm, mean aerror difference = 1.32°). Operative time was decreased in trainees. Therefore, they would benefit from such a system that could also serve for educational purposes. The majority of surgeons who strongly agreed that such a navigation system would prove very helpful in complex deformities, also stated that it would be helpful in everyday orthognathic procedures. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs.

    Science.gov (United States)

    Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus

    2016-03-02

    A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs

  6. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  7. [Financing of inpatient orthopedics and trauma surgery in the G-DRG system 2010].

    Science.gov (United States)

    Franz, D; Schemmann, F; Roeder, N; Mahlke, L

    2010-08-01

    The German DRG (diagnosis-related groups) system forms the basis for billing inpatient hospital services. It includes not only the case groups (G-DRGs), but also additional and innovation payments. This paper analyzes and evaluates the relevant developments of the G-DRG System 2010 for orthopedics and traumatology from the medical and classification perspectives. Analyses of relevant diagnoses, medical procedures and G-DRGs in the versions 2009 and 2010 based on the publications of the German DRG institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI) were carried out. The DRG catalog is has grown from 8 to 1,200 G-DRGs. A number of codes for surgical measures have been newly established or modified. Here, the identification and the correct and performance-based mapping of complex and elaborate scenarios was again the focus of the restructuring of the G-DRG system. The G-DRG structure in orthopedics and traumatology has been changed, especially in the areas of spinal surgery and surgery of the upper and lower extremities. The actual impact of the changes may vary depending on the individual hospital services. For the first time since the introduction of the G-DRG system, the pure numerical changes at the level of DRGs themselves are so marginal that only part of the DRG users in the hospitals will register them. The changes implemented not only a high selectivity between complex and less complex scenarios, but partly also unintended and unjustified revaluation of less complex measures. The G-DRG system has gained complexity again. Especially the G-DRG allocation of spinal surgery and multiple surgical interventions of the upper and/or lower extremities have reached such a complexity that only a few DRG users can follow them.

  8. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for ambulatory surgical centers - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of ambulatory surgical center ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey....

  9. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for hospital outpatient departments - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of hospital outpatient department ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS)...

  10. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    Energy Technology Data Exchange (ETDEWEB)

    Landman, Joanne [Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia); Kulawansa, Sagarika [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia (Australia); McCarthy, Michael; Troedson, Russell [Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia); Phillips, Michael [Western Australian Institute for Medical Research, University of Western Australia, Perth, Western Australia (Australia); Tinning, Jill [The Multidisciplinary Breast Service, Royal Perth Hospital, Perth, Western Australia (Australia); Taylor, Donna, E-mail: Donna.Taylor@health.wa.gov.au [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia (Australia); School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Department of Nuclear Medicine, Royal Perth Hospital, Perth, Western Australia (Australia)

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphy and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.

  11. An early validation of the Society for Vascular Surgery lower extremity threatened limb classification system.

    Science.gov (United States)

    Cull, David L; Manos, Ginger; Hartley, Michael C; Taylor, Spence M; Langan, Eugene M; Eidt, John F; Johnson, Brent L

    2014-12-01

    The Society for Vascular Surgery (SVS) recently established the Lower Extremity Threatened Limb Classification System, a staging system using Wound characteristic, Ischemia, and foot Infection (WIfI) to stratify the risk for limb amputation at 1 year. Although intuitive in nature, this new system has not been validated. The purpose of the following study was to determine whether the WIfI system is predictive of limb amputation and wound healing. Between 2007 and 2010, we prospectively obtained data related to wound characteristics, extent of infection, and degree of postrevascularization ischemia in 139 patients with foot wounds who presented for lower extremity revascularization (158 revascularization procedures). After adapting those data to the WIfI classifications, we analyzed the influence of wound characteristics, extent of infection, and degree of ischemia on time to wound healing; empirical Kaplan-Meier survival curves were compared with theoretical outcomes predicted by WIfI expert consensus opinion. Of the 158 foot wounds, 125 (79%) healed. The median time to wound healing was 2.7 months (range, 1-18 months). Factors associated with wound healing included presence of diabetes mellitus (P = .013), wound location (P = .049), wound size (P = .007), wound depth (P = .004), and degree of ischemia (P valid. Further validation of the WIfI classification system with multicenter data is justified. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery.

    Science.gov (United States)

    Shinkawa, Takeshi; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2017-05-01

    A ferromagnetic surgical system (FMwand®) is a new type of dissection device expected to reduce the risk of adjacent tissue damage. We reviewed 426 congenital cardiac operations with cardiopulmonary bypass through redo sternotomy to assess if this device prevented phrenic nerve injury. The ferromagnetic surgical system was used in 203 operations (47.7%) with regular electrocautery and scissors. The preoperative and operative details were similar between the operations with or without the ferromagnetic surgical system. The incidence of phrenic nerve injury was significantly lower with the ferromagnetic surgical system (0% vs 2.7%, P = 0.031). A logistic regression model showed that the use of the ferromagnetic surgical system was significantly associated with reduced odds of phrenic nerve injury (P < 0.001). © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Impact of an Event Reporting System on Resident Complication Reporting in Plastic Surgery Training: Addressing an ACGME and Plastic Surgery Milestone Project Core Competency.

    Science.gov (United States)

    Parikh, Rajiv P; Snyder-Warwick, Alison; Naidoo, Sybill; Skolnick, Gary B; Patel, Kamlesh B

    2017-11-01

    The Accreditation Council for Graduate Medical Education and Plastic Surgery Milestone Project has identified practice-based learning and improvement, which involves systematically analyzing current practices and implementing changes, as a core competency in residency education. In surgical care, complication reporting is an essential component of practice-based learning and improvement as complications are analyzed in morbidity and mortality conference for quality improvement. Unfortunately, current methods for capturing a comprehensive profile of complications may significantly underestimate the true occurrence of complications. Therefore, the objectives of this study are to evaluate an intervention for complication reporting and compare this to current practice, in a plastic surgery training program. This is a preintervention and postintervention study evaluating resident reporting of complications on a plastic surgery service. The intervention was an online event reporting system developed by department leadership and patient safety experts. The cohorts consisted of all patients undergoing surgery during two separate 3-month blocks bridged by an implementation period. A trained reviewer recorded complications, and this served as the reference standard. Fisher's exact test was used for binary comparisons. There were 32 complications detected in 219 patients from June to August of 2015 and 35 complications in 202 patients from October to December of 2015. The proportion of complications reported in the preintervention group was nine of 32 (28.1 percent). After the intervention, this significantly increased to 32 of 35 (91.4 percent) (p < 0.001). An intervention using an event reporting system, supported by departmental leadership, led to significant improvements in complication reporting by plastic surgery residents.

  14. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  15. [Orthopedic and trauma surgery in the German-DRG-System 2009].

    Science.gov (United States)

    Franz, D; Windolf, J; Siebert, C H; Roeder, N

    2009-01-01

    The German DRG-System was advanced into version 2009. For orthopedic and trauma surgery significant changes concerning coding of diagnoses, medical procedures and concerning the DRG-structure were made. Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2008 and 2009 based on the publications of the German DRG-institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). Changes for 2009 focussed on the development of DRG-structure, DRG-validation and codes for medical procedures to be used for very complex cases. The outcome of these changes for German hospitals may vary depending in the range of activities. G-DRG-System gained complexity again. High demands are made on correct and complete coding of complex orthopedic and trauma surgery cases. Quality of case-allocation within the G-DRG-System was improved. Nevertheless, further adjustments of the G-DRG-System especially for cases with severe injuries are necessary.

  16. Intra-abdominal recurrence of colorectal cancer detected by radioimmunoguided surgery (RIGS system)

    International Nuclear Information System (INIS)

    Sardi, A.; Workman, M.; Mojzisik, C.; Hinkle, G.; Nieroda, C.; Martin, E.W. Jr.

    1989-01-01

    Since 1986, 32 patients with metastatic colorectal cancer have undergone second-look radioimmunoguided surgery (RIGS system). The primary tumor was located in the right and transverse colon in 11 patients, left and sigmoid colon in 16, and rectum in five. The carcinoembryonic antigen level was elevated in 30 patients (94%); all patients underwent a computed tomographic scan of the abdomen and pelvis. The overall sensitivity of the computed tomographic scan was 41% (abdomen other than liver, 27%; liver, 58%; and pelvis, 22%). The RIGS system identified recurrent tumor in 81% of the patients. The most common site of metastasis was the liver (41%), independent of the primary location. Local/regional recurrences alone accounted for 40% of all recurrences. In six patients (18%), recurrent tumor was found only with the RIGS system. The RIGS system is more dependable in localizing clinically obscure metastases than other methods, and carcinoembryonic antigen testing remains the most accurate preoperative method to indicate suspected recurrences

  17. Error analysis for determination of accuracy of an ultrasound navigation system for head and neck surgery.

    Science.gov (United States)

    Kozak, J; Krysztoforski, K; Kroll, T; Helbig, S; Helbig, M

    2009-01-01

    The use of conventional CT- or MRI-based navigation systems for head and neck surgery is unsatisfactory due to tissue shift. Moreover, changes occurring during surgical procedures cannot be visualized. To overcome these drawbacks, we developed a novel ultrasound-guided navigation system for head and neck surgery. A comprehensive error analysis was undertaken to determine the accuracy of this new system. The evaluation of the system accuracy was essentially based on the method of error definition for well-established fiducial marker registration methods (point-pair matching) as used in, for example, CT- or MRI-based navigation. This method was modified in accordance with the specific requirements of ultrasound-guided navigation. The Fiducial Localization Error (FLE), Fiducial Registration Error (FRE) and Target Registration Error (TRE) were determined. In our navigation system, the real error (the TRE actually measured) did not exceed a volume of 1.58 mm(3) with a probability of 0.9. A mean value of 0.8 mm (standard deviation: 0.25 mm) was found for the FRE. The quality of the coordinate tracking system (Polaris localizer) could be defined with an FLE of 0.4 +/- 0.11 mm (mean +/- standard deviation). The quality of the coordinates of the crosshairs of the phantom was determined with a deviation of 0.5 mm (standard deviation: 0.07 mm). The results demonstrate that our newly developed ultrasound-guided navigation system shows only very small system deviations and therefore provides very accurate data for practical applications.

  18. Metabolic phenotype-microRNA data fusion analysis of the systemic consequences of Roux-en-Y gastric bypass surgery.

    OpenAIRE

    Wu, Q; Li, JV; Seyfried, F; le Roux, CW; Ashrafian, H; Athanasiou, T; Fenske, W; Darzi, A; Nicholson, JK; Holmes, E; Gooderham, NJ

    2015-01-01

    Background/Objectives: Bariatric surgery offers sustained marked weight loss and often remission of type 2 diabetes, yet the mechanisms of establishment of these health benefits are not clear. Subjects/Methods: We mapped the coordinated systemic responses of gut hormones, the circulating miRNAome and the metabolome in a rat model of Roux-en-Y gastric bypass (RYGB) surgery. Results: The response of circulating microRNAs (miRNAs) to RYGB was striking and selective. Analysis of 14 significantly ...

  19. A novel risk classification system for 30-day mortality in children undergoing surgery

    Science.gov (United States)

    Walter, Arianne I.; Jones, Tamekia L.; Huang, Eunice Y.; Davis, Robert L.

    2018-01-01

    A simple, objective and accurate way of grouping children undergoing surgery into clinically relevant risk groups is needed. The purpose of this study, is to develop and validate a preoperative risk classification system for postsurgical 30-day mortality for children undergoing a wide variety of operations. The National Surgical Quality Improvement Project-Pediatric participant use file data for calendar years 2012–2014 was analyzed to determine preoperative variables most associated with death within 30 days of operation (D30). Risk groups were created using classification tree analysis based on these preoperative variables. The resulting risk groups were validated using 2015 data, and applied to neonates and higher risk CPT codes to determine validity in high-risk subpopulations. A five-level risk classification was found to be most accurate. The preoperative need for ventilation, oxygen support, inotropic support, sepsis, the need for emergent surgery and a do not resuscitate order defined non-overlapping groups with observed rates of D30 that vary from 0.075% (Very Low Risk) to 38.6% (Very High Risk). When CPT codes where death was never observed are eliminated or when the system is applied to neonates, the groupings remained predictive of death in an ordinal manner. PMID:29351327

  20. Making Safe Surgery Affordable: Design of a Surgical Drill Cover System for Scale.

    Science.gov (United States)

    Buchan, Lawrence L; Black, Marianne S; Cancilla, Michael A; Huisman, Elise S; Kooyman, Jeremy J R; Nelson, Scott C; OʼHara, Nathan N; OʼBrien, Peter J; Blachut, Piotr A

    2015-10-01

    Many surgeons in low-resource settings do not have access to safe, affordable, or reliable surgical drilling tools. Surgeons often resort to nonsterile hardware drills because they are affordable, robust, and efficient, but they are impossible to sterilize using steam. A promising alternative is to use a Drill Cover system (a sterilizable fabric bag plus surgical chuck adapter) so that a nonsterile hardware drill can be used safely for surgical bone drilling. Our objective was to design a safe, effective, affordable Drill Cover system for scale in low-resource settings. We designed our device based on feedback from users at Mulago Hospital (Kampala, Uganda) and focused on 3 main aspects. First, the design included a sealed barrier between the surgical field and hardware drill that withstands pressurized fluid. Second, the selected hardware drill had a maximum speed of 1050 rpm to match common surgical drills and reduce risk of necrosis. Third, the fabric cover was optimized for ease of assembly while maintaining a sterile technique. Furthermore, with the Drill Cover approach, multiple Drill Covers can be provided with a single battery-powered drill in a "kit," so that the drill can be used in back-to-back surgeries without requiring immediate sterilization. The Drill Cover design presented here provides a proof-of-concept for a product that can be commercialized, produced at scale, and used in low-resource settings globally to improve access to safe surgery.

  1. Do Scoring Systems Help in Predicting Survival Following Ruptured Abdominal Aortic Aneurysm Surgery?

    Science.gov (United States)

    Gatt, Marcel; Goldsmith, Paul; Martinez, Marcos; Barandiaran, Jesus; Grover, Kartikae; El-Barghouti, Naif; Perry, Eugene P

    2009-01-01

    INTRODUCTION The aim of this study was to assess the value of the Hardman Index and the Glasgow Aneurysm Score in predicting postoperative mortality in patients with ruptured abdominal aortic aneurysm (rAAA), and to assess the correlation between the two. PATIENTS AND METHODS Patients admitted with rAAA were identified from a hospital database. Hospital records were reviewed and a retrospective Hardman Index and Glasgow Aneurysm Score was calculated. Poor postoperative prognosis was considered at a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3. RESULTS A total of 96 patients with a median age of 77.5 years (interquartile range, 71–83 years) and a male:female ratio of 2:1 were identified. Of these, 37 patients were not offered surgery and this was associated with 100% mortality. Of the 59 operated patients, 36 (61%) patients died postoperatively. Operated patients had a median Glasgow Aneurysm Score of 91 (interquartile range, 77–101) and a Hardman Index of 2 (interquartile range, 1–2). In this group, a Glasgow Aneurysm Score > 95 or a Hardman Index ≥ 3 was not associated with mortality (P = 0.10 and P = 0.79, respectively). Correlation between the scoring systems was poor (+0.42 τb). CONCLUSIONS The scoring systems assessed did not help predict the outcome of rAAA surgery, and correlated poorly with each other. They do not aid clinical judgement. PMID:19102824

  2. Effect of an 8K ultra-high-definition television system in a case of laparoscopic gynecologic surgery.

    Science.gov (United States)

    Aoki, Yoichi; Matsuura, Masahiko; Chiba, Toshio; Yamashita, Hiromasa

    2017-09-01

    Various endoscopic devices have been developed for advanced minimally invasive surgery. We recently applied a new 8K ultra-high-definition television system during laparoscopic treatment of endometriosis. The procedure, which is described in detail, stands as the first reported application of an 8K ultra-high-definition system for laparoscopic gynecologic surgery. Comparison is made between depiction of the lesion by the new system and depiction by a full high-definition system. Improved diagnostic accuracy resulted from the increased image resolution, and we believe that this and other advantages will lead to widespread acceptance and further application of 8K ultra-high-definition systems in the field of gynecologic surgery.

  3. Designing a wearable navigation system for image-guided cancer resection surgery.

    Science.gov (United States)

    Shao, Pengfei; Ding, Houzhu; Wang, Jinkun; Liu, Peng; Ling, Qiang; Chen, Jiayu; Xu, Junbin; Zhang, Shiwu; Xu, Ronald

    2014-11-01

    A wearable surgical navigation system is developed for intraoperative imaging of surgical margin in cancer resection surgery. The system consists of an excitation light source, a monochromatic CCD camera, a host computer, and a wearable headset unit in either of the following two modes: head-mounted display (HMD) and Google glass. In the HMD mode, a CMOS camera is installed on a personal cinema system to capture the surgical scene in real-time and transmit the image to the host computer through a USB port. In the Google glass mode, a wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A software program is written in Python to call OpenCV functions for image calibration, co-registration, fusion, and display with augmented reality. The imaging performance of the surgical navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex vivo tissue model. Surgical margins identified by the wearable navigation system are co-incident with those acquired by a standard small animal imaging system, indicating the technical feasibility for intraoperative surgical margin detection. The proposed surgical navigation system combines the sensitivity and specificity of a fluorescence imaging system and the mobility of a wearable goggle. It can be potentially used by a surgeon to identify the residual tumor foci and reduce the risk of recurrent diseases without interfering with the regular resection procedure.

  4. Reconciliation of international administrative coding systems for comparison of colorectal surgery outcome.

    Science.gov (United States)

    Munasinghe, A; Chang, D; Mamidanna, R; Middleton, S; Joy, M; Penninckx, F; Darzi, A; Livingston, E; Faiz, O

    2014-07-01

    Significant variation in colorectal surgery outcomes exists between different countries. Better understanding of the sources of variable outcomes using administrative data requires alignment of differing clinical coding systems. We aimed to map similar diagnoses and procedures across administrative coding systems used in different countries. Administrative data were collected in a central database as part of the Global Comparators (GC) Project. In order to unify these data, a systematic translation of diagnostic and procedural codes was undertaken. Codes for colorectal diagnoses, resections, operative complications and reoperative interventions were mapped across the respective national healthcare administrative coding systems. Discharge data from January 2006 to June 2011 for patients who had undergone colorectal surgical resections were analysed to generate risk-adjusted models for mortality, length of stay, readmissions and reoperations. In all, 52 544 case records were collated from 31 institutions in five countries. Mapping of all the coding systems was achieved so that diagnosis and procedures from the participant countries could be compared. Using the aligned coding systems to develop risk-adjusted models, the 30-day mortality rate for colorectal surgery was 3.95% (95% CI 0.86-7.54), the 30-day readmission rate was 11.05% (5.67-17.61), the 28-day reoperation rate was 6.13% (3.68-9.66) and the mean length of stay was 14 (7.65-46.76) days. The linkage of international hospital administrative data that we developed enabled comparison of documented surgical outcomes between countries. This methodology may facilitate international benchmarking. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  5. Cost-Benefit Performance of Robotic Surgery Compared with Video-Assisted Thoracoscopic Surgery under the Japanese National Health Insurance System.

    Science.gov (United States)

    Kajiwara, Naohiro; Patrick Barron, James; Kato, Yasufumi; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    Medical economics have significant impact on the entire country. The explosion in surgical techniques has been accompanied by questions regarding actual improvements in outcome and cost-effectiveness, such as the da Vinci(®) Surgical System (dVS) compared with conventional video-assisted thoracic surgery (VATS). To establish a medical fee system for robot-assisted thoracic surgery (RATS), which is a system not yet firmly established in Japan. This study examines the cost benefit performance (CBP) based on medical fees compared with VATS and RATS under the Japanese National Health Insurance System (JNHIS) introduced in 2012. The projected (but as yet undecided) price in the JNHIS would be insufficient if institutions have less than even 200 dVS cases per year. Only institutions which perform more than 300 dVS operations per year would obtain a positive CBP with the projected JNHIS reimbursement. Thus, under the present conditions, it is necessary to perform at least 300 dVS operations per year in each institution with a dVS system to avoid financial deficit with current robotic surgical management. This may hopefully encourage a downward price revision of the dVS equipment by the manufacture which would result in a decrease in the cost per procedure.

  6. Minimally invasive single-site surgery for the digestive system: A technological review

    Directory of Open Access Journals (Sweden)

    Dhumane Parag

    2011-01-01

    Full Text Available Minimally Invasive Single Site (MISS surgery is a better terminology to explain the novel concept of scarless surgery, which is increasingly making its way into clinical practice. But, there are some difficulties. We review the existing technologies for MISS surgery with regards to single-port devices, endoscope and camera, instruments, retractors and also the future perspectives for the evolution of MISS surgery. While we need to move ahead cautiously and wait for the development of appropriate technology, we believe that the "Ultimate form of Minimally Invasive Surgery" will be a hybrid form of MISS surgery and Natural Orifice Transluminal Endoscopic Surgery, complimented by technological innovations from the fields of robotics and computer-assisted surgery.

  7. Chronic Renin-Angiotensin System (RAS) Blockade May Not Induce Hypotension During Anaesthesia for Bariatric Surgery.

    Science.gov (United States)

    Salvetti, Guido; Di Salvo, Claudio; Ceccarini, Giovanni; Abramo, Antonio; Fierabracci, Paola; Magno, Silvia; Piaggi, Paolo; Vitti, Paolo; Santini, Ferruccio

    2016-06-01

    The use of angiotensin-converting enzyme inhibitors (ACE-I) and angiotensin II receptor blockers (ARB) for the treatment of hypertensive obese patients is steadily increasing. Some studies have reported that the use of these drugs was associated with an increased risk of hypotensive episodes, during general anaesthesia. The number of bariatric procedures is also increasing worldwide, but there is a lack of studies investigating the hypotensive effect of renin-angiotensin system (RAS) blockers in severely obese patients during general anaesthesia for bariatric surgery. The aim of this pilot study was to evaluate hemodynamic changes induced by general anaesthesia in obese patients chronically treated with ACE-I or ARB compared to a control group not treated with antihypertensive therapy. Fourteen obese subjects (mean body mass index (BMI) 47.5 kg/m(2)) treated with ACE-I or ARB and twelve obese (mean BMI 45.7 kg/m2) controls not treated with antihypertensive therapy underwent general anaesthesia to perform laparoscopic bariatric surgery. Systolic blood pressure, diastolic blood pressure, and heart rate were monitored continuously and registered at different time points: T0 before induction, then at 2, 5, 7, 10, 15, 20, 30, 60, 90, 120, and 150 min after induction, and the last time point taken following recovery from anaesthesia. A progressive reduction of both systolic and diastolic blood pressure values was observed without significant differences between the two groups. A similar trend of heart rate values was observed. In conclusion, our pilot study suggests that RAS blockers may be continued during the perioperative period in patients undergoing bariatric surgery, without increasing the risk of hypotensive episodes.

  8. Attitudes, beliefs, and practices regarding electronic nicotine delivery systems in patients scheduled for elective surgery.

    Science.gov (United States)

    Kadimpati, Sandeep; Nolan, Margaret; Warner, David O

    2015-01-01

    Smokers are at increased risk of postoperative complications. Electronic nicotine delivery systems (ENDS; or electronic cigarettes) could be a useful tool to reduce harm in the perioperative period. This pilot study examined the attitudes, beliefs, and practices of smokers scheduled for elective surgery regarding ENDS. This was a cross-sectional survey of current cigarette smokers who were evaluated in a preoperative clinic before elective surgery at Mayo Clinic. Measures included demographic characteristics, smoking history, 2 indices assessing the perception of how smoking affected health risks, ENDS use history, and 3 indices assessing interest in, perceived benefits of, and barriers to using ENDS in the perioperative period. Of the 112 smokers who completed the survey, 62 (55%) had tried ENDS and 24 (21%) reported current use. The most commonly stated reason for using ENDS was to quit smoking. Approximately 2 in 3 participants would be willing to use ENDS to help them reduce or eliminate perioperative cigarette use, and similar proportions perceived health benefits of doing so. Of the factors studied, only attempted to quit within the last year was significantly associated with increased interest in the perioperative use of ENDS (P=.03). Compared with participants who had tried ENDS (n=62), those who had never tried ENDS (n=50) had a significantly increased interest in the perioperative use of ENDS. A substantial proportion of patients scheduled for elective surgery had tried ENDS and would consider using ENDS to reduce perioperative use of cigarettes. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  9. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    Science.gov (United States)

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. The Auckland Cataract Study: Assessing Preoperative Risk Stratification Systems for Phacoemulsification Surgery in a Teaching Hospital.

    Science.gov (United States)

    Kim, Bia Z; Patel, Dipika V; Sherwin, Trevor; McGhee, Charles N J

    2016-11-01

    To evaluate 2 preoperative risk stratification systems for assessing the risk of complications in phacoemulsification cataract surgery, performed by residents, fellows, and attending physicians in a public teaching hospital. Cohort study. One observer assessed the clinical data of 500 consecutive cases, prior to phacoemulsification cataract surgery performed between April and June 2015 at Greenlane Clinical Centre, Auckland, New Zealand. Preoperatively 2 risk scores were calculated for each case using the Muhtaseb and Buckinghamshire risk stratification systems. Complications, intraoperative and postoperative, and visual outcomes were analyzed in relation to these risk scores. Intraoperative complication rates increased with higher risk scores using the Muhtaseb or Buckinghamshire stratification system (P = .001 and P = .003, respectively, n = 500). The odds ratios for residents and fellows were not significantly different from attending physicians after case-mix adjustment according to risk scores (P > .05). Postoperative complication rates increased with higher Buckinghamshire risk scores but not with Muhtaseb scores (P = .014 and P = .094, respectively, n = 476). Postoperative corrected-distance visual acuity was poorer with higher risk scores (P < .001 for both, n = 476). This study confirms that the risk of intraoperative complications increases with higher preoperative risk scores. Furthermore, higher risk scores correlate with poorer postoperative visual acuity and the Buckinghamshire risk score also correlates with postoperative complications. Therefore, preoperative assessment using such risk stratification systems could assist individual informed consent, preoperative surgical planning, safe allocation of cases to trainees, and more meaningful analyses of outcomes for individual surgeons and institutions. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Emprego de sistemas robóticos na cirurgia cardiovascular Robotic systems in cardiovascular surgery

    Directory of Open Access Journals (Sweden)

    Roberto T. Sant'Anna

    2004-06-01

    Full Text Available O desenvolvimento de sistemas robóticos para cirurgia teve início na década de 80, por solicitação do exército norte-americano, que antevia a possibilidade de realizar operações em teatros de guerra, distantes do local onde estava o cirurgião. Entretanto, o primeiro uso em humanos só ocorreu anos mais tarde, numa ressecção transuretral de hiperplasia benigna de próstata. Cirurgiões cardíacos foram logo atraídos pela técnica robótica devido a possível aplicação com reduzido caráter invasivo; esperava-se menor trauma cirúrgico e redução da dor, morbidade, tempo de internação e custo do procedimento. Atualmente, de forma restrita e em casos selecionados, robôs são usados para revascularização do miocárdio e implante de marcapasso em cirurgias cardíacas totalmente endoscópicas; podendo também constituir apoio visual na retirada de artéria torácica interna, reconstrução valvar mitral e correção de defeitos congênitos. Utilizando o robô auxiliar AESOP® para controle do videotoracoscópio, com controle vocal por meio do sistema HERMES®, temos realizado dissecção da artéria torácica interna, implante de eletrodo ventricular esquerdo e abordagem de defeitos congênitos na cirurgia de correção. Apesar do entusiasmo científico inicial com a cirurgia robótica, ainda não existe evidência clara de superioridade desta técnica em relação à operação convencional, em termos de resultado. Isto se aplica também ao custo, pois o investimento inicial na aquisição de sistema cirúrgico completo (console, controle de vídeo, instrumental provavelmente é compensado após muitos procedimentos e longo intervalo. Mas é certo que a cirurgia robótica terá um lugar no futuro, possibilitando aprendizagem, telepresença e realização de procedimentos pouco invasivos, embora complexos.The development of robotic systems for surgery started in the 80's, motivated by the US army's need for surgical procedure in

  12. Fungal endophthalmitis caused by Paecilomyces variotii following cataract surgery: a presumed operating room air-conditioning system contamination.

    Science.gov (United States)

    Tarkkanen, Ahti; Raivio, Virpi; Anttila, Veli-Jukka; Tommila, Petri; Ralli, Reijo; Merenmies, Lauri; Immonen, Ilkka

    2004-04-01

    To report a case of delayed fungal endophthalmitis by Paecilomyces variotii following uncomplicated cataract surgery. To our knowledge this is the first reported case of postoperative endophthalmitis by this species. We report the longterm clinical follow-up of an 83-year-old female who underwent uncomplicated sutureless, small-incision cataract surgery. She developed recurring uveitis 4 months after surgery. Vitreous tap and finally complete vitrectomy with removal of the capsular bag including the intraocular lens were performed. Fungi were studied by histopathology and culture. At histopathological examination, the fungi were found to be closely related with the capsular bag. A few mononuclear inflammatory cells were encountered. At culture, Paecilomyces variotii, a common ubiquitous non-pathogenic saprophyte, was identified. Despite systemic, intravitreal and topical antifungal therapy after vitrectomy the uveitis recurred several times, but no fungal organisms were isolated from the repeat intraocular specimen. At 18 months postoperatively the subject's visual acuity was finger counting at 2 metres. At the time of surgery the operating room air-conditioning system was undergoing repairs. Cases of fungal endophthalmitis after contamination from air-conditioning ventilation systems have been reported before, but none of the cases reported have been caused by P. variotii. P. variotii, a non-pathogenic environmental saprophyte, may be disastrous if introduced into the eye. International recommendations on the environmental control of the operating room air-conditioning ventilation system should be strictly followed. No intraoperative surgery should be undertaken while the air-conditioning system is undergoing repairs or service.

  13. Microcoaxial cataract surgery outcomes: comparison of 1.8 mm system and 2.2 mm system.

    Science.gov (United States)

    Lee, Kyung-Min; Kwon, Hyung-Goo; Joo, Choun-Ki

    2009-05-01

    To compare clinical outcomes of a 1.8 mm and a 2.2 mm microcoaxial cataract surgery system. Department of Ophthalmology and Visual Science, Kangnam St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. In a prospective study, eyes were randomly selected to have phacoemulsification using a Stellaris system or an Intrepid Infiniti system. The initial incision size was 1.8 mm and 2.2 mm, respectively. Measured intraoperative parameters included phacoemulsification time, mean cumulative dissipated ultrasound energy (CDE), change in incision size at each step of surgery, and total volume of balanced salt solution (BSS) used. The best corrected visual acuity (BCVA), corneal astigmatism, corneal thickness, and endothelial cell count were evaluated preoperatively and postoperatively. The study evaluated 86 eyes of 78 patients (43 eyes in each group). There were no significant differences in postoperative BCVA, surgically induced astigmatism, or amount of BSS used between the 2 systems (P >.05). However, for high-density cataracts, the 1.8 mm group had a greater change between the initial incision size and the incision size after phacoemulsification (P = .019, nuclear opalescence [NO] NO3; P = .001, NO4), a longer phacoemulsification time (P = .013, NO3), greater mean CDE (P = .005, NO3; P = .001, NO4), and greater corneal endothelial cell loss (P = .003, NO4). Both systems were safe and effective in microcoaxial phacoemulsification. The 1.8 mm system performed better with cortical-type cataract and the 2.2 mm system, with high-density nuclear-type cataract.

  14. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  15. Follow the light: projector-based augmented reality intracorporeal system for laparoscopic surgery.

    Science.gov (United States)

    Edgcumbe, Philip; Singla, Rohit; Pratt, Philip; Schneider, Caitlin; Nguan, Christopher; Rohling, Robert

    2018-04-01

    A projector-based augmented reality intracorporeal system (PARIS) is presented that includes a miniature tracked projector, tracked marker, and laparoscopic ultrasound (LUS) transducer. PARIS was developed to improve the efficacy and safety of laparoscopic partial nephrectomy (LPN). In particular, it has been demonstrated to effectively assist in the identification of tumor boundaries during surgery and to improve the surgeon's understanding of the underlying anatomy. PARIS achieves this by displaying the orthographic projection of the cancerous tumor on the kidney's surface. The performance of PARIS was evaluated in a user study with two surgeons who performed 32 simulated robot-assisted partial nephrectomies. They performed 16 simulated partial nephrectomies with PARIS for guidance and 16 simulated partial nephrectomies with only an LUS transducer for guidance. With PARIS, there was a significant reduction [30% ([Formula: see text])] in the amount of healthy tissue excised and a trend toward a more accurate dissection around the tumor and more negative margins. The combined point tracking and reprojection root-mean-square error of PARIS was 0.8 mm. PARIS' proven ability to improve key metrics of LPN surgery and qualitative feedback from surgeons about PARIS supports the hypothesis that it is an effective surgical navigation tool.

  16. Investigation of objective evaluation system of anatomical knowledge and operative techniques in education for rhinologic surgery

    International Nuclear Information System (INIS)

    Ishimasa, Hiroshi; Murata, Hideyuki

    2006-01-01

    Operative technique and approach method for the nasal and paranasal sinuses, areas of anatomical complexity and high individual variation, have been transformed dramatically in recent years with the introduction of the endoscope. However, due to surgeons' unfamiliarity with the technique and anatomical misidentification, medical errors show no sign of significant decline. As endoscopic sinus surgery (ESS) is an indirect operating procedure, conducted while watching a video monitor, it is necessary for the surgeon to become accustomed to the special properties of the endoscope, namely, the lack of perspective projection. Until now, surgical training has made repetitive use of video material and donated cadavers for skill practice, and a system of one-to-one instruction whereby instruction is received from a lead surgeon while the learner joins the actual procedure as an assistant. That is to say, there has been no objective method of evaluating individual proficiency until now. In our study, evaluation of individual anatomical knowledge and thought process until task completion, objective evaluation of surgical instrument handling and technique, and evaluation of knowledge required in actual surgeries are discussed Then an individually responsive method of surgical instruction with self-evaluation and self-cognition will be sought. (author)

  17. Quality management system of a university cardiac surgery department according to DIN EN ISO 9001 : 2000.

    Science.gov (United States)

    Beholz, S; Koch, C; Konertz, W

    2003-06-01

    A quality management system (QMS) will improve quality in health care units. This report describes the introduction of a QMS according to ISO 9001:2000 in a university cardiovascular surgery department. First, a thorough analysis of all processes of patient treatment and clinical research was obtained. Multiple interfaces were defined to different departments as well as to administration units. We evaluated and optimized all necessary resources, evaluating customer satisfaction using patients' and referring physicians' surveys. We started quality rounds including surgeons, nurses and technicians. Based on this preparation, we redefined and explained all processes including their responsibilities and necessary resources in the quality manual. After a process of 18 months, an independent, accredited organization recommended that our QMS be given certification according to ISO 9001:2000. Certification of a university cardiovascular surgery department according to ISO 9001:2000 is possible, and may represent the first step towards total quality management (TQM). In complex health care units, certification of separate departments may help generate a consciousness of quality on the way to TQM.

  18. A novel smart navigation system for intramedullary nailing in orthopedic surgery.

    Directory of Open Access Journals (Sweden)

    Jaesuk Choi

    Full Text Available This paper proposes a novel smart surgical navigation system for intramedullary nailing in orthopedic surgery. Using a handle-integrated laser guidance module, the system can target a drill insertion point onto skin, indicating an accurate target position to perpendicularly access an invisible distal hole. The proposed handle-integration-based fixation of the laser guidance module precisely defines the relative position of the module with respect to the distal hole. Consequently, unlike conventional systems, the proposed system can indicate the target insertion point without any help from bulky and costly external position-tracking equipment that is usually required for compensating disturbances generated by external impacts. After insertion, a correct drilling direction toward the distal hole is guided by real-time drilling angle measurement modules-one integrated with the nail handle and the other with the drill body. Each module contains a 9-axis inertial sensor and a Bluetooth communication device. These two modules work together to provide real-time drilling angle data, allowing calculation of the directional error toward the center of the distal hole in real time. The proposed system removes the need for fluoroscopy and provides a compact and cost-effective solution compared with conventional systems.

  19. A novel optimal coordinated control strategy for the updated robot system for single port surgery.

    Science.gov (United States)

    Bai, Weibang; Cao, Qixin; Leng, Chuntao; Cao, Yang; Fujie, Masakatsu G; Pan, Tiewen

    2017-09-01

    Research into robotic systems for single port surgery (SPS) has become widespread around the world in recent years. A new robot arm system for SPS was developed, but its positioning platform and other hardware components were not efficient. Special features of the developed surgical robot system make good teleoperation with safety and efficiency difficult. A robot arm is combined and used as new positioning platform, and the remote center motion is realized by a new method using active motion control. A new mapping strategy based on kinematics computation and a novel optimal coordinated control strategy based on real-time approaching to a defined anthropopathic criterion configuration that is referred to the customary ease state of human arms and especially the configuration of boxers' habitual preparation posture are developed. The hardware components, control architecture, control system, and mapping strategy of the robotic system has been updated. A novel optimal coordinated control strategy is proposed and tested. The new robot system can be more dexterous, intelligent, convenient and safer for preoperative positioning and intraoperative adjustment. The mapping strategy can achieve good following and representation for the slave manipulator arms. And the proposed novel control strategy can enable them to complete tasks with higher maneuverability, lower possibility of self-interference and singularity free while teleoperating. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Cost-Effectiveness of Surgery, Stereotactic Body Radiation Therapy, and Systemic Therapy for Pulmonary Oligometastases

    Energy Technology Data Exchange (ETDEWEB)

    Lester-Coll, Nataniel H., E-mail: nataniel.lester-coll@yale.edu [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Rutter, Charles E.; Bledsoe, Trevor J. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Goldberg, Sarah B. [Department of Medicine (Medical Oncology), Yale University School of Medicine, New Haven, Connecticut (United States); Decker, Roy H.; Yu, James B. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States)

    2016-06-01

    Introduction: Pulmonary oligometastases have conventionally been managed with surgery and/or systemic therapy. However, given concerns about the high cost of systemic therapy and improvements in local treatment of metastatic cancer, the optimal cost-effective management of these patients is unclear. Therefore, we sought to assess the cost-effectiveness of initial management strategies for pulmonary oligometastases. Methods and Materials: A cost-effectiveness analysis using a Markov modeling approach was used to compare average cumulative costs, quality adjusted life years (QALYs), and incremental cost-effectiveness ratios (ICERs) among 3 initial disease management strategies: video-assisted thoracic surgery (VATS) wedge resection, stereotactic body radiation therapy (SBRT), and systemic therapy among 5 different cohorts of patient disease: (1) melanoma; (2) non-small cell lung cancer adenocarcinoma without an EGFR mutation (NSCLC AC); (3) NSCLC with an EGFR mutation (NSCLC EGFRm AC); (4) NSCLC squamous cell carcinoma (NSCLC SCC); and (5) colon cancer. One-way sensitivity analyses and probabilistic sensitivity analyses were performed to analyze uncertainty with regard to model parameters. Results: In the base case, SBRT was cost effective for melanoma, with costs/net QALYs of $467,787/0.85. In patients with NSCLC, the most cost-effective strategies were SBRT for AC ($156,725/0.80), paclitaxel/carboplatin for SCC ($123,799/0.48), and erlotinib for EGFRm AC ($147,091/1.90). Stereotactic body radiation therapy was marginally cost-effective for EGFRm AC compared to erlotinib with an incremental cost-effectiveness ratio of $126,303/QALY. For colon cancer, VATS wedge resection ($147,730/2.14) was the most cost-effective strategy. Variables with the greatest influence in the model were erlotinib-associated progression-free survival (EGFRm AC), toxicity (EGFRm AC), cost of SBRT (NSCLC SCC), and patient utilities (all histologies). Conclusions: Video-assisted thoracic

  1. PACS for surgery and interventional radiology: Features of a Therapy Imaging and Model Management System (TIMMS)

    International Nuclear Information System (INIS)

    Lemke, Heinz U.; Berliner, Leonard

    2011-01-01

    Appropriate use of information and communication technology (ICT) and mechatronic (MT) systems is viewed by many experts as a means to improve workflow and quality of care in the operating room (OR). This will require a suitable information technology (IT) infrastructure, as well as communication and interface standards, such as specialized extensions of DICOM, to allow data interchange between surgical system components in the OR. A design of such an infrastructure, sometimes referred to as surgical PACS, but better defined as a Therapy Imaging and Model Management System (TIMMS), will be introduced in this article. A TIMMS should support the essential functions that enable and advance image guided therapy, and in the future, a more comprehensive form of patient-model guided therapy. Within this concept, the 'image-centric world view' of the classical PACS technology is complemented by an IT 'model-centric world view'. Such a view is founded in the special patient modelling needs of an increasing number of modern surgical interventions as compared to the imaging intensive working mode of diagnostic radiology, for which PACS was originally conceptualised and developed. The modelling aspects refer to both patient information and workflow modelling. Standards for creating and integrating information about patients, equipment, and procedures are vitally needed when planning for an efficient OR. The DICOM Working Group 24 (WG-24) has been established to develop DICOM objects and services related to image and model guided surgery. To determine these standards, it is important to define step-by-step surgical workflow practices and create interventional workflow models per procedures or per variable cases. As the boundaries between radiation therapy, surgery and interventional radiology are becoming less well-defined, precise patient models will become the greatest common denominator for all therapeutic disciplines. In addition to imaging, the focus of WG-24 is to serve

  2. PACS for surgery and interventional radiology: features of a Therapy Imaging and Model Management System (TIMMS).

    Science.gov (United States)

    Lemke, Heinz U; Berliner, Leonard

    2011-05-01

    Appropriate use of information and communication technology (ICT) and mechatronic (MT) systems is viewed by many experts as a means to improve workflow and quality of care in the operating room (OR). This will require a suitable information technology (IT) infrastructure, as well as communication and interface standards, such as specialized extensions of DICOM, to allow data interchange between surgical system components in the OR. A design of such an infrastructure, sometimes referred to as surgical PACS, but better defined as a Therapy Imaging and Model Management System (TIMMS), will be introduced in this article. A TIMMS should support the essential functions that enable and advance image guided therapy, and in the future, a more comprehensive form of patient-model guided therapy. Within this concept, the "image-centric world view" of the classical PACS technology is complemented by an IT "model-centric world view". Such a view is founded in the special patient modelling needs of an increasing number of modern surgical interventions as compared to the imaging intensive working mode of diagnostic radiology, for which PACS was originally conceptualised and developed. The modelling aspects refer to both patient information and workflow modelling. Standards for creating and integrating information about patients, equipment, and procedures are vitally needed when planning for an efficient OR. The DICOM Working Group 24 (WG-24) has been established to develop DICOM objects and services related to image and model guided surgery. To determine these standards, it is important to define step-by-step surgical workflow practices and create interventional workflow models per procedures or per variable cases. As the boundaries between radiation therapy, surgery and interventional radiology are becoming less well-defined, precise patient models will become the greatest common denominator for all therapeutic disciplines. In addition to imaging, the focus of WG-24 is to serve

  3. A computer-supported management of photographic documentation in plastic surgery - System development and its clinical application.

    Science.gov (United States)

    Korczak, Karol; Kasielska-Trojan, Anna; Niedźwiedziński, Marian; Antoszewski, Bogusław

    2017-07-01

    Photographic documentation is very important for plastic, reconstructive, and especially aesthetic surgery procedures. It can be used to improve patient care as well as to carry out scientific research. The results of our previous studies confirmed a strong demand for Information Technology (IT) systems dedicated to plastic surgery. Unfortunately, most of the solutions of this type are not suited to the actual needs. For this reason we decided to develop a reliable system for photographic documentation storage. The Plastic Reconstructive Esthetic Surgery Photo System (PRESsPhoto) was developed and finally deployed in the Plastic, Reconstructive and Aesthetic Surgery Clinic of the Medical University in Łódź (Poland). Preliminary single-center performance tests proved that the PRESsPhoto system is easy to use and provides, inter alia, rapid data search and data entry as well as data security. In the future the PRESsPhoto system should be able to cooperate with Hospital Information Systems (HIS). The process of development and deployment of the PRESsPhoto system is an example of good cooperation between health care providers and the informatics, which resulted in a system that meets the expectations of plastic surgeons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Augmented reality as an aid in maxillofacial surgery: validation of a wearable system allowing maxillary repositioning.

    Science.gov (United States)

    Badiali, Giovanni; Ferrari, Vincenzo; Cutolo, Fabrizio; Freschi, Cinzia; Caramella, Davide; Bianchi, Alberto; Marchetti, Claudio

    2014-12-01

    We present a newly designed, localiser-free, head-mounted system featuring augmented reality as an aid to maxillofacial bone surgery, and assess the potential utility of the device by conducting a feasibility study and validation. Our head-mounted wearable system facilitating augmented surgery was developed as a stand-alone, video-based, see-through device in which the visual features were adapted to facilitate maxillofacial bone surgery. We implement a strategy designed to present augmented reality information to the operating surgeon. LeFort1 osteotomy was chosen as the test procedure. The system is designed to exhibit virtual planning overlaying the details of a real patient. We implemented a method allowing performance of waferless, augmented-reality assisted bone repositioning. In vitro testing was conducted on a physical replica of a human skull, and the augmented reality system was used to perform LeFort1 maxillary repositioning. Surgical accuracy was measured with the aid of an optical navigation system that recorded the coordinates of three reference points (located in anterior, posterior right, and posterior left positions) on the repositioned maxilla. The outcomes were compared with those expected to be achievable in a three-dimensional environment. Data were derived using three levels of surgical planning, of increasing complexity, and for nine different operators with varying levels of surgical skill. The mean error was 1.70 ± 0.51 mm. The axial errors were 0.89 ± 0.54 mm on the sagittal axis, 0.60 ± 0.20 mm on the frontal axis, and 1.06 ± 0.40 mm on the craniocaudal axis. The simplest plan was associated with a slightly lower mean error (1.58 ± 0.37 mm) compared with the more complex plans (medium: 1.82 ± 0.71 mm; difficult: 1.70 ± 0.45 mm). The mean error for the anterior reference point was lower (1.33 ± 0.58 mm) than those for both the posterior right (1.72 ± 0.24 mm) and posterior left points (2.05 ± 0.47 mm). No significant difference

  5. Landmark-based augmented reality system for paranasal and transnasal endoscopic surgeries.

    Science.gov (United States)

    Thoranaghatte, Ramesh; Garcia, Jaime; Caversaccio, Marco; Widmer, Daniel; Gonzalez Ballester, Miguel A; Nolte, Lutz-P; Zheng, Guoyan

    2009-12-01

    In this paper we present a landmark-based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope. Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set-up. Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set-up (metallic grid) and was 2.25 mm during cadaver studies. A novel landmark-based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future. Copyright (c) 2009 John Wiley & Sons, Ltd.

  6. [Comparison between the Austrian and German DRG systems in hand surgery].

    Science.gov (United States)

    Lotter, O; Jaminet, P; Schwarzach, S; Schaller, H E

    2013-02-01

    Diagnosis-Related Groups (DRG) are a patient classification system grouping related types of patients treated to the resources they consumed. In this analysis, we compared the Austrian and the German DRG systems. The 15 most common hand surgical diagnoses and their corresponding operative treatment were transferred into the Austrian system. Thus, the length of stay and the reimbursement of both countries could be obtained and compared. The mean values and the median values of the upper and lower thresholds of length of stay as well as the average length of stay were all lower in Austria compared to Germany. Reimbursement in Germany was higher in 13 of 19 cases. Total proceeds amounted to 1.67 million in the German and 1.70 million in the Austrian health care system. Considering the purchasing power applying consumer prize parities, the difference of reimbursement between the countries rose to 130,000 which equals a difference of almost 8%. Reimbursement of the top 15 diagnoses in hand surgery in Austria is 8% higher than in Germany. Except for one case, mean values as well as upper and lower thresholds of length of stay are considerably shorter in Austria. Comparison of international data to refine a national compensation system is advocated.

  7. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Guillermo M.; Elizondo, Maria L. [CORE Dental Clinic, Resistencia (Argentina)

    2014-06-15

    The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

  8. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    Science.gov (United States)

    Elizondo, María L.

    2014-01-01

    Purpose The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties. PMID:24944966

  9. Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

    International Nuclear Information System (INIS)

    Rosa, Guillermo M.; Elizondo, Maria L.

    2014-01-01

    The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

  10. Effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA1c.

    Science.gov (United States)

    Chadburn, Andrew J; Garman, Elizabeth; Abbas, Raad; Modupe, Anu; Ford, Clare; Thomas, Osmond L; Chugh, Sanjiv; Deshpande, Shreeram; Gama, Rousseau

    2017-07-01

    Background In acutely ill patients with new onset hyperglycaemia, plasma glucose cannot reliably distinguish between stress hyperglycaemia and undiagnosed diabetes mellitus. We, therefore, investigated the diagnostic reliability of glycated haemoglobin (HbA1c) in acute illness by prospectively evaluating the effect of the systemic inflammatory response, as provoked by elective orthopaedic surgery, on HbA 1c . Methods HbA 1c and serum C-reactive protein concentrations were compared before and two days after elective knee or hip surgery in 30 patients without diabetes. C-reactive protein was used to assess the systemic inflammatory response. Results The mean (standard deviation) serum C-reactive protein increased following surgery (4.8 [7.5] vs. 179.7 [61.9] mg/L; P<0.0001). HbA 1c was similar before and after surgery (39.2 [5.4] vs. 38.1 [5.1] mmol/moL, respectively; P = 0.4363). Conclusions HbA 1c is unaffected within two days of a systemic inflammatory response as provoked by elective orthopaedic surgery. This suggests that HbA 1c may be able to differentiate newly presenting type 2 diabetes mellitus from stress hyperglycaemia in acutely ill patients with new onset hyperglycaemia.

  11. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  12. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  13. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  14. Probe-guided surgery: metastases of a papillary thyroid carcinoma. Surgical Excision

    International Nuclear Information System (INIS)

    Kowadlo, A.R.; Zund, S.; Perez Irigoyen, C.

    2008-01-01

    A male patient with papillary thyroid cancer -follicular variety- is chosen to be presented. After thyroidectomy, lymphadenectomy and therapeutic dose of radioiodine treatments, cancer relapse was observed. After thyrotrophin suppressive therapy with l-thyroxine, a high serum thyroglobulin concentration was observed. The Ultrasonography (US) and Magnetic Resonance (MR) images showed visible node structures in the neck. This node structures were probably going to concentrate I-131 as seen in the fi rst whole body scan after therapeutic dose. Therefore a radio-guided surgery was planned as the best choice. (Institute Gustave Roussy protocol). A therapeutic dose of radioiodine (I-131) was given and up to the 4th day a whole body scan was performed. In the 5th day a gamma- probe-guided surgery was performed as well, and localized metastatic foci in the pretracheal region and under right recurrent laryngeal nerve. No other foci were identified ed with the probe at surgery. Forty eight hours after surgery a new whole-body scan was made again. The procedure was successful. The metastatic lesions were completely dissected. The last whole body scan showed that radioiodine concentration had disappeared at all. Forty fi ve days and three months after surgery under levothyroxine treatment, the serum thyroglobulin level concentration decrease to very low values. (authors) [es

  15. A novel robotic system for single-port urologic surgery: first clinical investigation.

    Science.gov (United States)

    Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld

    2014-12-01

    The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all

  16. A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery

    Science.gov (United States)

    Zhang, Zeshu; Pei, Jing; Wang, Dong; Hu, Chuanzhen; Ye, Jian; Gan, Qi; Liu, Peng; Yue, Jian; Wang, Benzhong; Shao, Pengfei; Povoski, Stephen P.; Martin, Edward W.; Yilmaz, Alper; Tweedle, Michael F.; Xu, Ronald X.

    2016-03-01

    Surgical resection remains the primary curative intervention for cancer treatment. However, the occurrence of a residual tumor after resection is very common, leading to the recurrence of the disease and the need for re-resection. We develop a surgical Google Glass navigation system that combines near infrared fluorescent imaging and ultrasonography for intraoperative detection of sites of tumor and assessment of surgical resection boundaries, well as for guiding sentinel lymph node (SLN) mapping and biopsy. The system consists of a monochromatic CCD camera, a computer, a Google Glass wearable headset, an ultrasonic machine and an array of LED light sources. All the above components, except the Google Glass, are connected to a host computer by a USB or HDMI port. Wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A control program is written in C++ to call OpenCV functions for image calibration, processing and display. The technical feasibility of the system is tested in both tumor simulating phantoms and in a human subject. When the system is used for simulated phantom resection tasks, the tumor boundaries, invisible to the naked eye, can be clearly visualized with the surgical Google Glass navigation system. This system has also been used in an IRB approved protocol in a single patient during SLN mapping and biopsy in the First Affiliated Hospital of Anhui Medical University, demonstrating the ability to successfully localize and resect all apparent SLNs. In summary, our tumor simulating phantom and human subject studies have demonstrated the technical feasibility of successfully using the proposed goggle navigation system during cancer surgery.

  17. Augmented reality system for oral surgery using 3D auto stereoscopic visualization.

    Science.gov (United States)

    Tran, Huy Hoang; Suenaga, Hideyuki; Kuwana, Kenta; Masamune, Ken; Dohi, Takeyoshi; Nakajima, Susumu; Liao, Hongen

    2011-01-01

    We present an augmented reality system for oral and maxillofacial surgery in this paper. Instead of being displayed on a separated screen, three-dimensional (3D) virtual presentations of osseous structures and soft tissues are projected onto the patient's body, providing surgeons with exact knowledge of depth information of high risk tissues inside the bone. We employ a 3D integral imaging technique which produce motion parallax in both horizontal and vertical direction over a wide viewing area in this study. In addition, surgeons are able to check the progress of the operation in real-time through an intuitive 3D based interface which is content-rich, hardware accelerated. These features prevent surgeons from penetrating into high risk areas and thus help improve the quality of the operation. Operational tasks such as hole drilling, screw fixation were performed using our system and showed an overall positional error of less than 1 mm. Feasibility of our system was also verified with a human volunteer experiment.

  18. Design and control of MR haptic master/slave robot system for minimally invasive surgery

    Science.gov (United States)

    Uhm, Chang-Ho; Nguyen, Phoung Bac; Choi, Seung-Bok

    2013-04-01

    In this work, magnetorheological (MR) haptic master and slave robot for minimally invasive surgery (MIS) have been designed and tested. The proposed haptic master consists of four actuators; three MR brakes featuring gimbal structure for 3-DOF rotation motion(X, Y and Z axes) and one MR linear actuator for 1-DOF translational motion. The proposed slave robot which is connected with the haptic master has vertically multi- joints, and it consists of four DC servomotors; three for positioning endoscope and one for spinning motion. We added a fixed bar with a ball joint on the base of the slave for the endoscope position at the patient's abdomen to maintain safety. A gimbal structure at the end of the slave robotic arm for the last joint rotates freely with respect to the pivot point of the fixed bar. This master-slave system runs as if a teleoperation system through TCP/IP connection, programmed by LabVIEW. In order to achieve the desired position trajectory, a proportional-integral-derivative (PID) controller is designed and implemented. It has been demonstrated that the effective tracking control performances for the desired motion are well achieved and presented in time domain. At last, an experiment in virtual environments is undertaken to investigate the effectiveness of the MR haptic master device for MIS system.

  19. Accuracy of the all patient refined diagnosis related groups classification system in congenital heart surgery.

    Science.gov (United States)

    Parnell, Aimee S; Shults, Justine; Gaynor, J William; Leonard, Mary B; Dai, Dingwei; Feudtner, Chris

    2014-02-01

    Administrative data are increasingly used to evaluate clinical outcomes and quality of care in pediatric congenital heart surgery (CHS) programs. Several published analyses of large pediatric administrative data sets have relied on the All Patient Refined Diagnosis Related Groups (APR-DRG, version 24) diagnostic classification system. The accuracy of this classification system for patients undergoing CHS is unclear. We performed a retrospective cohort study of all 14,098 patients 0 to 5 years of age undergoing any of six selected congenital heart operations, ranging in complexity from isolated closure of a ventricular septal defect to single-ventricle palliation, at 40 tertiary-care pediatric centers in the Pediatric Health Information Systems database between 2007 and 2010. Assigned APR-DRGs (cardiac versus noncardiac) were compared using χ2 or Fisher's exact tests between those patients admitted during the first day of life versus later and between those receiving extracorporeal membrane oxygenation support versus those not. Recursive partitioning was used to assess the greatest determinants of APR-DRG type in the model. Every patient admitted on day 1 of life was assigned to a noncardiac APR-DRG (pDRG (pDRG experienced a significantly increased mortality (pDRG coding has systematic misclassifications, which may result in inaccurate reporting of CHS case volumes and mortality. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Improving patient care in cardiac surgery using Toyota production system based methodology.

    Science.gov (United States)

    Culig, Michael H; Kunkle, Richard F; Frndak, Diane C; Grunden, Naida; Maher, Thomas D; Magovern, George J

    2011-02-01

    A new cardiac surgery program was developed in a community hospital setting using the operational excellence (OE) method, which is based on the principles of the Toyota production system. The initial results of the first 409 heart operations, performed over the 28 months between March 1, 2008, and June 30, 2010, are presented. Operational excellence methodology was taught to the cardiac surgery team. Coaching started 2 months before the opening of the program and continued for 24 months. Of the 409 cases presented, 253 were isolated coronary artery bypass graft operations. One operative death occurred. According to the database maintained by The Society of Thoracic Surgeons, the risk-adjusted operative mortality rate was 61% lower than the regional rate. Likewise, the risk-adjusted rate of major complications was 57% lower than The Society of Thoracic Surgeons regional rate. Daily solution to determine cause was attempted on 923 distinct perioperative problems by all team members. Using the cost of complications as described by Speir and coworkers, avoiding predicted complications resulted in a savings of at least $884,900 as compared with the regional average. By the systematic use of a real time, highly formatted problem-solving methodology, processes of care improved daily. Using carefully disciplined teamwork, reliable implementation of evidence-based protocols was realized by empowering the front line to make improvements. Low rates of complications were observed, and a cost savings of $3,497 per each case of isolated coronary artery bypass graft was realized. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. The systemic inflammome of severe obesity before and after bariatric surgery.

    Directory of Open Access Journals (Sweden)

    Ebymar Arismendi

    Full Text Available Obesity is associated with low-grade systemic inflammation. The "inflammome" is a network layout of the inflammatory pattern. The systemic inflammome of obesity has not been described as yet. We hypothesized that it can be significantly worsened by smoking and other comorbidities frequently associated with obesity, and ameliorated by bariatric surgery (BS. Besides, whether or not these changes are mirrored in the lungs is unknown, but obesity is often associated with pulmonary inflammation and bronchial hyperresponsiveness.We sought to: (1 describe the systemic inflammome of morbid obesity; (2 investigate the effects of sex, smoking, sleep apnea syndrome, metabolic syndrome and BS upon this systemic inflammome; and, (3 determine their interplay with pulmonary inflammation.We studied 129 morbidly obese patients (96 females; age 46 ± 12 years; body mass index [BMI], 46 ± 6 kg/m2 before and one year after BS, and 20 healthy, never-smokers, (43 ± 7 years, with normal BMI and spirometry.Before BS, compared with controls, all obese subjects displayed a strong and coordinated (inflammome systemic inflammatory response (adiponectin, C-reactive protein, interleukin (IL-8, IL-10, leptin, soluble tumor necrosis factor-receptor 1(sTNF-R1, and 8-isoprostane. This inflammome was not modified by sex, smoking, or coexistence of obstructive sleep apnea and/or metabolic syndrome. By contrast, it was significantly ameliorated, albeit not completely abolished, after BS. Finally, obese subjects had evidence of pulmonary inflammation (exhaled condensate that also decreased after BS.The systemic inflammome of morbid obesity is independent of sex, smoking status and/or comorbidities, it is significantly reduced by BS and mirrored in the lungs.

  2. [Complex surgical procedures in orthopedics and trauma surgery. A contribution to the proposal procedure for the DRG system in 2009].

    Science.gov (United States)

    Flohé, S; Nabring, J; Luetkes, P; Nast-Kolb, D; Windolf, J

    2008-10-01

    Since the DRG system was introduced in 2003/2004 the system for remuneration has been continually modified in conjunction with input from specialized medical associations. As part of this development of the payment system, the criteria for classification of a diagnosis-related group were further expanded and new functions were added. This contribution addresses the importance of the complex surgical procedures as criteria for subdivision of the DRG case-based lump sums in orthopedics and trauma surgery.

  3. Attitudes of surgeons to the use of postoperative markers of the systemic inflammatory response following elective surgery

    Directory of Open Access Journals (Sweden)

    Ross D. Dolan

    2017-09-01

    Conclusion: Although there was a limited response the majority of surgeons surveyed measure the systemic inflammatory response following elective surgery and use CRP measurements together with clinical findings to guide postoperative care. The present results provide a baseline against which future surveys can be compared.

  4. Hepatic Steatosis in Morbidly Obese Patients Undergoing Gastric Bypass Surgery: Assessment With Open-System 1H-MR Spectroscopy

    NARCIS (Netherlands)

    van Werven, Jochem R.; Schreuder, Tim C. M. A.; Aarts, Edo O.; Nederveen, Aart J.; Meijer, Jos W. R.; Berends, Frits J.; Janssen, Ignace M. C.; Mulder, Chris J.; Jansen, Peter L. M.; Stoker, Jaap

    2011-01-01

    The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis

  5. New CO2 laser waveguide systems: advances in surgery of tracheal stenosis

    Science.gov (United States)

    Stasche, Norbert; Bernecker, Frank; Hoermann, Karl

    1996-01-01

    The carbon dioxide laser is a well established tool in the surgical treatment of laryngeal and tracheal stenosis. Usually the laser beam is applied by a microscope/micromanipulator device. Different types of rigid laryngoscopes and bronchoscopes provide access to nearly every area of larynx, trachea and main bronchi. In order to be treated with this equipment the target tissue has to be in a straight optical axis with the laser beam output at the micromanipulator. We report about one patient who presented with severe dyspnea due to granulation tissue directly below his left vocal cord. He was suffering from tracheomalacia for several years and was successfully treated by tracheostomy and a Montgomery's silicone T-tube as a stent. Then granulation tissue blocked the upper orifice of the Montgomery's T-tube. First removal by a carbon dioxide laser beam through the laryngoscope would have required sacrificing his intact left vocal cord. We removed the obstructing tissue by using the ArthroLaseTM System: the carbon dioxide laser beam was conducted through a 90 degree bent rigid probe, using the tracheostomy as an access. This ArthroLaseTM System was originally designed for arthroscopic surgery. In this special case however it successfully extends the use of the carbon dioxide laser in otolaryngology.

  6. Single-incision laparoscopic surgery in a survival animal model using a transabdominal magnetic anchoring system.

    Science.gov (United States)

    Cho, Yong Beom; Park, Chan Ho; Kim, Hee Cheol; Yun, Seong Hyeon; Lee, Woo Yong; Chun, Ho-Kyung

    2011-12-01

    Though single-incision laparoscopic surgery (SILS) can reduce operative scarring and facilitates postoperative recovery, it does have some limitations, such as reduction in instrument working, difficulty in triangulation, and collision of instruments. To overcome these limitations, development of new instruments is needed. The aim of this study is to evaluate the feasibility and safety of a magnetic anchoring system in performing SILS ileocecectomy. Experiments were performed in a living dog model. Five dogs (26.3-29.2 kg) underwent ileocecectomy using a multichannel single port (OCTO port; Darim, Seoul, Korea). The port was inserted at the umbilicus and maintained a CO(2) pneumoperitoneum. Two magnet-fixated vascular clips were attached to the colon using an endoclip applicator, and it was held together across the abdominal wall by using an external handheld magnet. The cecum was then retracted in an upward direction by moving the external handheld magnet, and the mesocolon was dissected with Ultracision(®). Extracorporeal functional end-to-end anastomosis was done using a linear stapler. All animals survived during the observational period of 2 weeks, and then re-exploration was performed under general anesthesia for evaluation of intra-abdominal healing and complications. Mean operation time was 70 min (range 55-100 min), with each subsequent case taking less time. The magnetic anchoring system was effective in achieving adequate exposure in all cases. All animals survived and convalesced normally without evidence of clinical complication during the observation period. At re-exploration, all anastomoses were completely healed and there were no complications such as abscess, bleeding or organ injury. SILS ileocecectomy using a magnetic anchoring system was safe and effective in a dog model. The development of magnetic anchoring systems may be beneficial for overcoming the limitations of SILS.

  7. Robotic Laparoendoscopic Single-site Retroperitioneal Renal Surgery: Initial Investigation of a Purpose-built Single-port Surgical System.

    Science.gov (United States)

    Maurice, Matthew J; Ramirez, Daniel; Kaouk, Jihad H

    2017-04-01

    Robotic single-site retroperitoneal renal surgery has the potential to minimize the morbidity of standard transperitoneal and multiport approaches. Traditionally, technological limitations of non-purpose-built robotic platforms have hindered the application of this approach. To assess the feasibility of retroperitoneal renal surgery using a new purpose-built robotic single-port surgical system. This was a preclinical study using three male cadavers to assess the feasibility of the da Vinci SP1098 surgical system for robotic laparoendoscopic single-site (R-LESS) retroperitoneal renal surgery. We used the SP1098 to perform retroperitoneal R-LESS radical nephrectomy (n=1) and bilateral partial nephrectomy (n=4) on the anterior and posterior surfaces of the kidney. Improvements unique to this system include enhanced optics and intelligent instrument arm control. Access was obtained 2cm anterior and inferior to the tip of the 12th rib using a novel 2.5-cm robotic single-port system that accommodates three double-jointed articulating robotic instruments, an articulating camera, and an assistant port. The primary outcome was the technical feasibility of the procedures, as measured by the need for conversion to standard techniques, intraoperative complications, and operative times. All cases were completed without the need for conversion. There were no intraoperative complications. The operative time was 100min for radical nephrectomy, and the mean operative time was 91.8±18.5min for partial nephrectomy. Limitations include the preclinical model, the small sample size, and the lack of a control group. Single-site retroperitoneal renal surgery is feasible using the latest-generation SP1098 robotic platform. While the potential of the SP1098 appears promising, further study is needed for clinical evaluation of this investigational technology. In an experimental model, we used a new robotic system to successfully perform major surgery on the kidney through a single small

  8. Validation of risk assessment scoring systems for an audit of elective surgery for gastrointestinal cancer in elderly patients: an audit.

    Science.gov (United States)

    Wakabayashi, Hisao; Sano, Takanori; Yachida, Shinichi; Okano, Keiichi; Izuishi, Kunihiko; Suzuki, Yasuyuki

    2007-10-01

    The goal of this study was to validate the usefulness of risk assessment scoring systems for a surgical audit in elective digestive surgery for elderly patients. The validated scoring systems used were the Physiological and Operative Severity Score for enUmeration of Mortality and morbidity (POSSUM) and the Portsmouth predictor equation for mortality (P-POSSUM). This study involved 153 consecutive patients aged 75 years and older who underwent elective gastric or colorectal surgery between July 2004 and June 2006. A retrospective analysis was performed on data collected prior to each surgery. The predicted mortality and morbidity risks were calculated using each of the scoring systems and were used to obtain the observed/predicted (O/E) mortality and morbidity ratios. New logistic regression equations for morbidity and mortality were then calculated using the scores from the POSSUM system and applied retrospectively. The O/E ratio for morbidity obtained from POSSUM score was 0.23. The O/E ratios for mortality from the POSSUM score and the P-POSSUM were 0.15 and 0.38, respectively. Utilizing the new equations using scores from the POSSUM, the O/E ratio increased to 0.88. Both the POSSUM and P-POSSUM over-predicted the morbidity and mortality in elective gastrointestinal surgery for malignant tumors in elderly patients. However, if a surgical unit makes appropriate calculations using its own patient series and updates these equations, the POSSUM system can be useful in the risk assessment for surgery in elderly patients.

  9. En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?

    International Nuclear Information System (INIS)

    Lifrange, E.; Colin, C.; Dondelinger, R.F.; Fridman, V.

    2001-01-01

    This study was prospectively conducted to evaluate the clinical potential of the advanced breast biopsy instrumentation (ABBI) system as an alternative to needle localization and open surgery in the management of nonpalpable breast lesions (NPBL). One hundred and eighty-six consecutive patients were referred for management of NPBL. Thirty-six underwent an ABBI procedure, offered as a first step before possible surgery for lesions which would in any case have required complete excision. The 18 patients with a malignant ABBI biopsy underwent re-excision of the biopsy site and axillary dissection was carried out in cases of infiltrating carcinoma. The other 150 patients underwent image-guided needle biopsy. Following these procedures, 60/150 (40 %) patients underwent needle-guided surgery. Finally, 96/186 (51 %) patients required complete excision. A total of 43 benign lesions and 53 carcinomas were confirmed. Thirty-six out of 96 (38 %) excisions were obtained with the ABBI system; 17/43 (40 %) benign lesions and 11/53 (21 %) carcinomas were completely removed with the ABBI system. Out of 9 malignant specimens with a pathological size less than 10 mm, 5/9 (55 %) had tumor-free margins and in 8/9 (89 %) no residual disease was found at re-excision. The preliminary results of this study suggest that, in selected cases, en bloc excision using the ABBI procedure could be an alternative to conventional surgery. (orig.)

  10. [Comparison of hand surgery in the German and Italian DRG systems].

    Science.gov (United States)

    Lotter, O; Dolderer, J; Stahl, S; Atzei, A; Haerle, M; Schaller, H E

    2011-12-01

    Diagnosis-related groups (DRGs) are a patient classification system grouping related types of patients treated to the resources they consumed. In this analysis we compared the Italian and the German DRG systems regarding hand surgery with an emphasis on reimbursement of clinical cases. The 15 most common hand surgical diagnoses and their corresponding operative treatment in our clinic in 2009 were processed using a DRG grouper. The underlying data were transferred to the Italian system. Thus, the length of stay and the reimbursement of both countries could be obtained and compared. The latter was adjusted and corrected by the purchasing power of each country. The mean of the upper threshold of length of stay was 10 days in the German as well as the Italian system whereas the median was 2 times higher in Italy (6 vs. 12 days). Fifteen out of 19 cases showed higher reimbursement in Germany. The case mix index (CMI) of 0.917 in Germany represents a mean payment of 2,676 € per case. In Italy the hypothetical CMI of 0.635 resulted in a mean reimbursement of 1,853 € per case. The biggest difference in remuneration could be found for replantation of multiple fingers. For this service the German health-care system pays 12,320 € more than the Italian. Total proceeds of the top 15 diagnoses applying the number of cases treated in our clinic revealed 1.7 million € in the German and 1.2 million € in the Italian DRG system. Considering the purchasing power utilizing consumer prize parities, the difference of reimbursement between the countries decreased to 300,000 €. There is no mean length of stay per DRG in Italy, only the upper threshold of length of stay is determined. In most cases the latter is higher in Italy compared to Germany. The consumption of resources for finger replantation is not adequately represented in the Italian DRG system compared to finger amputation. Reimbursement of inpatient care is influenced by multiple factors not being subject

  11. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    Science.gov (United States)

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  12. Implementation of an Anesthesia Information Management System in an Ambulatory Surgery Center.

    Science.gov (United States)

    Mudumbai, Seshadri C

    2016-01-01

    Anesthesia information management systems (AIMS) are increasingly being implemented throughout the United States. However, little information exists on the implementation process for AIMS within ambulatory surgery centers (ASC). The objectives of this descriptive study are to document: 1) the phases of implementation of an AIMS at an ASC; and 2) lessons learnt from a socio-technical perspective. The ASC, within the Veterans Health Administration (VHA), has hosted an AIMS since 2008. As a quality improvement effort, we implemented a new version of the AIMS. This new version involved fundamental software changes to enhance clinical care such as real-time importing of laboratory data and total hardware exchange. The pre-implementation phase involved coordinated preparation over six months between multiple informatics teams along with local leadership. During this time, we conducted component, integration, and validation testing to ensure correct data flow from medical devices to AIMS and centralized databases. The implementation phase occurred in September 2014 over three days and was successful. Over the next several months, during post-implementation phase, we addressed residual items like latency of the application. Important lessons learnt from the implementation included the utility of partnering early with executive leadership; ensuring end user acceptance of new clinical workflow; continuous testing of data flow; use of a staged rollout; and providing additional personnel throughout implementation. Implementation of an AIMS at an ASC can utilize methods developed for large hospitals. However, issues unique to an ASC such as limited number of support personnel and distinctive workflows must be considered.

  13. Short Hospitalization system: a new way of interpreting day surgery care.

    Science.gov (United States)

    Rago, Rocco; Franceschini, Francesca; Tomassini, Carlo R

    2016-01-01

    Today's poorer income on the one hand and the more and more unbearable costs on the other, call for solutions to maintain public health through proper and collective care. We need to think of a new dimension of health, to found a modern and innovative approach, which can combine the respect of healthcare rights with the optimization of resources. Worldwide, franchises serving millions of people every year succeed in limiting operating costs and still offer a service and a quality equal to single businesses. Let's imagine every single Day Surgery Unit (DSU), within its own hospital, as a single trade: starting a process of centralized management and subsequent affiliation with other DSUs, they would increase their healthcare offer by means of solid organization, efficiency and foresight that with a strong focus on innovation and continuous updating, thus increasing its range of consumers and containing management costs. The Short Hospitalization System (SHS) is the proposed project, which is not only a type of hospitalization which is different from the ordinary, but also an innovative clinical-organizational model, with an important economic impact, where the management and maximization of the different hospital flows (care, professional, logistical, information), as well as the ability to implement strategies to anticipate them are crucial. The expected benefits are both clinically and socially relevant. Among them: 1) best practice build up; 2) lower impact on daily habits and increased patient satisfaction; 3) reduction of social and health expenditure.

  14. [How does the German DRG system differentiate and reimburse vitreoretinal surgery in diabetic patients?].

    Science.gov (United States)

    Krause, M; Goldschmidt, A J; Berg, M; Kropf, S; Sachs, A; Gatzioufas, Z; Brückner, K; Seitz, B

    2008-10-01

    The German DRG system (G-DRG system) is required to assign medical cases with similar costs correctly into a particular group, each case within the group receiving the same amount of reimbursement. At the same time the system should allow all-inclusive reimbursement, not necessarily reflecting the exact costs of each case. These opposite goals and the so far limited calculation basis raise the question of how the G-DRG system actually processes and reimburses empirically collected in-hospital treatment data. In 2005, 112 patients were admitted to the University Eye Hospital, University of the Saarland. All patients had diabetic retinopathy and required at least one vitreoretinal procedure. Demographic and clinical data were collected by using the hospital information system and the coding software KODIP. For statistic evaluation, principal diagnoses, ancillary diagnoses and procedures were each reassigned to particular groups. Reimbursement was calculated based on the case data of the year 2005. Also, the case data were reassigned with respect to calculation of reimbursement for the years 2006 and 2007. The results were compared with federal G-DRG calculation data. Mean age of the patients was 65.8 +/- 11.1 years, length of stay in-hospital was 9.3 +/- 3.2 days. In the 66 patients requiring general anaesthesia the cumulative length of stay in the operation room was 148.4 +/- 39.5 minutes, the cumulative duration of surgery was 86.3 +/- 34.1 minutes. In the 50 patients requiring local anaesthesia the cumulative length of stay in the operation room was 137.8 +/- 51.8 minutes, the cumulative duration of surgery was 81.6 +/- 43.6 minutes. The patients had 1.9 +/- 0.8 principal diagnoses, 14.4 +/- 5.8 ancillary diagnoses and 3.4 +/- 1.6 procedures. Twenty-five of 112 patients (22.3 %) were assigned to DRG C 03Z (1), 82 of 112 patients (73.2 %) were assigned to DRG C 17Z (2). Five patients were assigned to other DRG. Compared with the federal calculation data, our own

  15. Cardiac Surgery Costs According to the Preoperative Risk in the Brazilian Public Health System

    Directory of Open Access Journals (Sweden)

    David Provenzale Titinger

    2015-01-01

    Full Text Available Abstract Background: Heart surgery has developed with increasing patient complexity. Objective: To assess the use of resources and real costs stratified by risk factors of patients submitted to surgical cardiac procedures and to compare them with the values reimbursed by the Brazilian Unified Health System (SUS. Method: All cardiac surgery procedures performed between January and July 2013 in a tertiary referral center were analyzed. Demographic and clinical data allowed the calculation of the value reimbursed by the Brazilian SUS. Patients were stratified as low, intermediate and high-risk categories according to the EuroSCORE. Clinical outcomes, use of resources and costs (real costs versus SUS were compared between established risk groups. Results: Postoperative mortality rates of low, intermediate and high-risk EuroSCORE risk strata showed a significant linear positive correlation (EuroSCORE: 3.8%, 10%, and 25%; p < 0.0001, as well as occurrence of any postoperative complication EuroSCORE: 13.7%, 20.7%, and 30.8%, respectively; p = 0.006. Accordingly, length-of-stay increased from 20.9 days to 24.8 and 29.2 days (p < 0.001. The real cost was parallel to increased resource use according to EuroSCORE risk strata (R$ 27.116,00 ± R$ 13.928,00 versus R$ 34.854,00 ± R$ 27.814,00 versus R$ 43.234,00 ± R$ 26.009,00, respectively; p < 0.001. SUS reimbursement also increased (R$ 14.306,00 ± R$ 4.571,00 versus R$ 16.217,00 ± R$ 7.298,00 versus R$ 19.548,00 ± R$935,00; p < 0.001. However, as the EuroSCORE increased, there was significant difference (p < 0.0001 between the real cost increasing slope and the SUS reimbursement elevation per EuroSCORE risk strata. Conclusion: Higher EuroSCORE was related to higher postoperative mortality, complications, length of stay, and costs. Although SUS reimbursement increased according to risk, it was not proportional to real costs.

  16. Precision in robotic rectal surgery using the da Vinci Xi system and integrated table motion, a technical note.

    Science.gov (United States)

    Panteleimonitis, Sofoklis; Harper, Mick; Hall, Stuart; Figueiredo, Nuno; Qureshi, Tahseen; Parvaiz, Amjad

    2017-09-15

    Robotic rectal surgery is becoming increasingly more popular among colorectal surgeons. However, time spent on robotic platform docking, arm clashing and undocking of the platform during the procedure are factors that surgeons often find cumbersome and time consuming. The newest surgical platform, the da Vinci Xi, coupled with integrated table motion can help to overcome these problems. This technical note aims to describe a standardised operative technique of single docking robotic rectal surgery using the da Vinci Xi system and integrated table motion. A stepwise approach of the da Vinci docking process and surgical technique is described accompanied by an intra-operative video that demonstrates this technique. We also present data collected from a prospectively maintained database. 33 consecutive rectal cancer patients (24 male, 9 female) received robotic rectal surgery with the da Vinci Xi during the preparation of this technical note. 29 (88%) patients had anterior resections, and four (12%) had abdominoperineal excisions. There were no conversions, no anastomotic leaks and no mortality. Median operation time was 331 (249-372) min, blood loss 20 (20-45) mls and length of stay 6.5 (4-8) days. 30-day readmission rate and re-operation rates were 3% (n = 1). This standardised technique of single docking robotic rectal surgery with the da Vinci Xi is safe, feasible and reproducible. The technological advances of the new robotic system facilitate the totally robotic single docking approach.

  17. Operation and force analysis of the guide wire in a minimally invasive vascular interventional surgery robot system

    Science.gov (United States)

    Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian

    2015-03-01

    To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.

  18. Antimicrobial delivery systems for local infection prophylaxis in orthopedic- and trauma surgery

    NARCIS (Netherlands)

    ter Boo, Gert-Jan A.; Grijpma, Dirk W.; Moriarty, Thomas E.; Richards, Robert G.; Eglin, David

    Infectious complications occur in a minor but significant portion of the patients undergoing joint replacement surgery or fracture fixation, particularly those with severe open fractures, those undergoing revision arthroplasty or those at elevated risk because of poor health status. Once

  19. Antimicrobial delivery systems for local infection prophylaxis in orthopedic- and trauma surgery

    NARCIS (Netherlands)

    ter Boo, G.A.; Grijpma, Dirk W.; Moriarty, T.F.; Richards, R.G.; Eglin, D.

    2015-01-01

    Infectious complications occur in a minor but significant portion of the patients undergoing joint replacement surgery or fracture fixation, particularly those with severe open fractures, those undergoing revision arthroplasty or those at elevated risk because of poor health status. Once

  20. A clinical pilot study of a modular video-CT augmentation system for image-guided skull base surgery

    Science.gov (United States)

    Liu, Wen P.; Mirota, Daniel J.; Uneri, Ali; Otake, Yoshito; Hager, Gregory; Reh, Douglas D.; Ishii, Masaru; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2012-02-01

    Augmentation of endoscopic video with preoperative or intraoperative image data [e.g., planning data and/or anatomical segmentations defined in computed tomography (CT) and magnetic resonance (MR)], can improve navigation, spatial orientation, confidence, and tissue resection in skull base surgery, especially with respect to critical neurovascular structures that may be difficult to visualize in the video scene. This paper presents the engineering and evaluation of a video augmentation system for endoscopic skull base surgery translated to use in a clinical study. Extension of previous research yielded a practical system with a modular design that can be applied to other endoscopic surgeries, including orthopedic, abdominal, and thoracic procedures. A clinical pilot study is underway to assess feasibility and benefit to surgical performance by overlaying CT or MR planning data in realtime, high-definition endoscopic video. Preoperative planning included segmentation of the carotid arteries, optic nerves, and surgical target volume (e.g., tumor). An automated camera calibration process was developed that demonstrates mean re-projection accuracy (0.7+/-0.3) pixels and mean target registration error of (2.3+/-1.5) mm. An IRB-approved clinical study involving fifteen patients undergoing skull base tumor surgery is underway in which each surgery includes the experimental video-CT system deployed in parallel to the standard-of-care (unaugmented) video display. Questionnaires distributed to one neurosurgeon and two otolaryngologists are used to assess primary outcome measures regarding the benefit to surgical confidence in localizing critical structures and targets by means of video overlay during surgical approach, resection, and reconstruction.

  1. Establishing a portfolio of quality-improvement projects in pediatric surgery through advanced improvement leadership systems.

    Science.gov (United States)

    Gerrein, Betsy T; Williams, Christina E; Von Allmen, Daniel

    2013-01-01

    Formal quality-improvement (QI) projects require that participants are educated in QI methods to provide them with the capability to carry out successful, meaningful work. However, orchestrating a portfolio of projects that addresses the strategic mission of the institution requires an extension of basic QI training to provide the division or business unit with the capacity to successfully develop and manage the portfolio. Advanced Improvement Leadership Systems is a program to help units create a meaningful portfolio. This program, used by the Division of Pediatric General and Thoracic Surgery at Cincinnati Children's Hospital Medical Center, helped establish a portfolio of targeted QI projects designed to achieve outstanding outcomes at competitive costs in multiple clinical areas aligned with the institution's strategic goals (improve disease-based outcomes, patient safety, flow, and patient and family experience). These objectives are addressed in an institutional strategic plan built around 5 core areas: Safety, Productivity, Care Coordination and Outcomes, Patient and Family Experience, and Value. By combining the portfolio of QI projects with improvements in the divisional infrastructure, effective improvement efforts were realized throughout the division. In the 9 months following the program, divisional capability resulted in a 16.5% increase (5.7% to 22.2%) of formally trained staff working on 10 QI teams. Concurrently, a leadership team, designed to coordinate projects, remove barriers, and provide technical support, provided the capacity to pursue this ongoing effort. The Advanced Improvement Leadership Systems program increased the Division's efficiency and effectiveness in pursing the QI mission that is integral at our hospital.

  2. Establishing a Portfolio of Quality-Improvement Projects in Pediatric Surgery through Advanced Improvement Leadership Systems

    Science.gov (United States)

    Gerrein, Betsy T; Williams, Christina E; von Allmen, Daniel

    2013-01-01

    Formal quality-improvement (QI) projects require that participants are educated in QI methods to provide them with the capability to carry out successful, meaningful work. However, orchestrating a portfolio of projects that addresses the strategic mission of the institution requires an extension of basic QI training to provide the division or business unit with the capacity to successfully develop and manage the portfolio. Advanced Improvement Leadership Systems is a program to help units create a meaningful portfolio. This program, used by the Division of Pediatric General and Thoracic Surgery at Cincinnati Children’s Hospital Medical Center, helped establish a portfolio of targeted QI projects designed to achieve outstanding outcomes at competitive costs in multiple clinical areas aligned with the institution’s strategic goals (improve disease-based outcomes, patient safety, flow, and patient and family experience). These objectives are addressed in an institutional strategic plan built around 5 core areas: Safety, Productivity, Care Coordination and Outcomes, Patient and Family Experience, and Value. By combining the portfolio of QI projects with improvements in the divisional infrastructure, effective improvement efforts were realized throughout the division. In the 9 months following the program, divisional capability resulted in a 16.5% increase (5.7% to 22.2%) of formally trained staff working on 10 QI teams. Concurrently, a leadership team, designed to coordinate projects, remove barriers, and provide technical support, provided the capacity to pursue this ongoing effort. The Advanced Improvement Leadership Systems program increased the Division’s efficiency and effectiveness in pursing the QI mission that is integral at our hospital. PMID:24361020

  3. Development and validation of a tool for non-technical skills evaluation in robotic surgery-the ICARS system.

    Science.gov (United States)

    Raison, Nicholas; Wood, Thomas; Brunckhorst, Oliver; Abe, Takashige; Ross, Talisa; Challacombe, Ben; Khan, Mohammed Shamim; Novara, Giacomo; Buffi, Nicolo; Van Der Poel, Henk; McIlhenny, Craig; Dasgupta, Prokar; Ahmed, Kamran

    2017-12-01

    Non-technical skills (NTS) are being increasingly recognised as vital for safe surgical practice. Numerous NTS rating systems have been developed to support effective training and assessment. Yet despite the additional challenges posed by robotic surgery, no NTS rating systems have been developed for this unique surgical environment. This study reports the development and validation of the first NTS behavioural rating system for robotic surgery. A comprehensive index of all relevant NTS behaviours in robotic surgery was developed through observation of robotic theatre and interviews with robotic surgeons. Using a Delphi methodology, a panel of 16 expert surgeons was consulted to identify behaviours important to NTS assessment. These behaviours were organised into an appropriate assessment template. Experts were consulted on the feasibility, applicability and educational impact of ICARS. An observational trial was used to validate ICARS. 73 novice, intermediate and expert robotic surgeons completed a urethrovesical anastomosis within a simulated operating room. NTS were tested using four scripted scenarios of increasing difficulty. Performances were video recorded. Robotic and NTS experts assessed the videos post hoc using ICARS and the standard behavioural rating system, NOn-Technical Skills for Surgeons (NOTSS). 28 key non-technical behaviours were identified by the expert panel. The finalised behavioural rating system was organised into four principle domains and seven categories. Expert opinion strongly supported its implementation. ICARS was found to be equivalent to NOTSS on Bland-Altman analysis and accurately differentiated between novice, intermediate and expert participants, p = 0.01. Moderate agreement was found between raters, Krippendorff's alpha = 0.4. The internal structure of ICARS was shown to be consistent and reliable (median Cronbach alpha = 0.92, range 0.85-0.94). ICARS is the first NTS behavioural rating system developed for robotic

  4. Intraoperative computed tomography with an integrated navigation system in stabilization surgery for complex craniovertebral junction malformation.

    Science.gov (United States)

    Yu, Xinguang; Li, Lianfeng; Wang, Peng; Yin, Yiheng; Bu, Bo; Zhou, Dingbiao

    2014-07-01

    This study was designed to report our preliminary experience with stabilization procedures for complex craniovertebral junction malformation (CVJM) using intraoperative computed tomography (iCT) with an integrated neuronavigation system (NNS). To evaluate the workflow, feasibility and clinical outcome of stabilization procedures using iCT image-guided navigation for complex CVJM. The stabilization procedures in CVJM are complex because of the area's intricate geometry and bony structures, its critical relationship to neurovascular structures and the intricate biomechanical issues involved. A sliding gantry 40-slice computed tomography scanner was installed in a preexisting operating room. The images were transferred directly from the scanner to the NNS using an automated registration system. On the basis of the analysis of intraoperative computed tomographic images, 23 cases (11 males, 12 females) with complicated CVJM underwent navigated stabilization procedures to allow more control over screw placement. The age of these patients were 19-52 years (mean: 33.5 y). We performed C1-C2 transarticular screw fixation in 6 patients to produce atlantoaxial arthrodesis with better reliability. Because of a high-riding transverse foramen on at least 1 side of the C2 vertebra and an anomalous vertebral artery position, 7 patients underwent C1 lateral mass and C2 pedicle screw fixation. Ten additional patients were treated with individualized occipitocervical fixation surgery from the hypoplasia of C1 or constraints due to C2 bone structure. In total, 108 screws were inserted into 23 patients using navigational assistance. The screws comprised 20 C1 lateral mass screws, 26 C2, 14 C3, or 4 C4 pedicle screws, 32 occipital screws, and 12 C1-C2 transarticular screws. There were no vascular or neural complications except for pedicle perforations that were detected in 2 (1.9%) patients and were corrected intraoperatively without any persistent nerves or vessel damage. The overall

  5. Gender and socioeconomic status as determinants of waiting time for inpatient surgery in a system with implicit queue management.

    Science.gov (United States)

    Arnesen, Kjell E; Erikssen, Jan; Stavem, Knut

    2002-12-01

    In a system with implicit queue management, to examine gender and socioeconomic status as determinants of waiting time for inpatient surgery, after adjusting for other potential predictors. A cohort of 452 subjects was examined in outpatient clinics of a general hospital and referred to inpatient surgery. They were followed until scheduled hospital admission (n=396) or until the requested procedure no longer was relevant (n=56). We compared waiting time between groups from referral date until hospital admission, using Kaplan-Meier estimates of waiting times and log rank test. A Cox proportional hazards model was used for assessing the risk ratio (RR) of hospital admission for scheduled surgery. Gender and socioeconomic status could not explain variations in waiting time. However, patients with suspected/verified neoplastic disease or a risk of serious deterioration without treatment had markedly shorter waiting times than the reference groups, with adjusted RR (95% confidence intervals (95%CI)) of time to receiving in-patient surgery of 2.3 (1.7-3.0) and 2.0 (1.3-3.0), respectively. Being on sick leave was associated with shorter waiting time, adjusted RR of 1.7 (1.2-2.5). Referrals from within the hospital or other hospitals had also shorter waiting times than referrals from primary health care physicians, adjusted RR=1.4 (1.1-1.8). There was no evidence of bias against women or people in lower socioeconomic classes in this implicit queue management system. However, patients' access to inpatient surgery was associated with malignancy, prognosis, sick leave status, physician experience, referral pattern and the major diagnosis category.

  6. Comparison of corneal power obtained from VERION image-guided surgery system and four other devices

    Directory of Open Access Journals (Sweden)

    Lin HY

    2017-07-01

    Full Text Available Hung-Yuan Lin,1,* Hsin-Yang Chen,1,2,* Han Bor Fam,3 Ya-Jung Chuang,1 Ronald Yeoh,4 Pi-Jung Lin5 1Universal Eye Center, Zhongli Branch, Zhongli County, TaoYuan City, Taiwan, Republic of China; 2Ophthalmology Department, Ningbo First Hospital, Ningbo, Zhejiang Province, People’s Republic of China; 3Ophthalmology Department, Tan Tock Seng Hospital, Jalan Tan Tock Seng, 4Ophthalmology Department, Eye and Retina Surgeons, Camden Medical Centre, Singapore; 5Universal Eye Center, Xinnan Branch, Taipei City, Taiwan, Republic of China *These authors contributed equally to this work Purpose: To assess the corneal keratometric values obtained using the VERION image-guided surgery system and other devices.Methods: This study evaluated the right eyes of 115 cataract patients before intraocular lens (IOL implantation through consecutive tests using 5 devices: VERION Reference Unit , Placido-based corneal topography (OPD-Scan III, monochromatic light-emitting diodes (LenStar LS900 and AL-Scan, and rotary prism technology (auto kerato-refractometer KR-8800. Analyzed parameters were corneal steep and flat keratometric values (Ks and Kf and corneal astigmatism and axis. These parameters were evaluated using the one-sample two-tailed t-test and the 95% limits of agreement (95% LOAs between the devices.Results: The mean corneal cylinder value measurements were -0.97±0.63 D, -0.88± 0.60 D, -0.90±0.69 D, -0.90±0.67 D, and -0.83±0.60 D with VERION, LenStar, AL-Scan (2.4 mm, OPD III, and KR-8800, respectively. Only KR-8800 showed a significant difference from VERION in the corneal cylinder value (P<0.05. The mean differences in the Kf and Ks of VERION compared to those of OPD III were 0.18±0.45 D and 0.17±0.38 D (P<0.05, respectively. The 95% LOAs of Bland–Altman analysis for the corneal astigmatism axis of the VERION with LenStar, AL-Scan (2.4 mm, OPD III, and KR-8800 were -26.25° to 58.71°, -20.61° to 47.44°, -25.03° to 58.98°, and -27.85

  7. Turbinate surgery

    Science.gov (United States)

    Turbinectomy; Turbinoplasty; Turbinate reduction; Nasal airway surgery; Nasal obstruction - turbinate surgery ... There are several types of turbinate surgery: Turbinectomy: All or ... This can be done in several different ways, but sometimes a ...

  8. Bariatric Surgery

    Science.gov (United States)

    ... often. Each type of surgery has advantages and disadvantages. Bariatric Surgery Benefits Bariatric surgery can improve many ... Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  9. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  10. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  11. Laparoscopic surgery for benign and malign diseases of the digestive system: indications, limitations, and evidence.

    Science.gov (United States)

    Küper, Markus Alexander; Eisner, Friederike; Königsrainer, Alfred; Glatzle, Jörg

    2014-05-07

    The laparoscopic technique was introduced in gastrointestinal surgery in the mid 1980s. Since then, the development of this technique has been extraordinary. Triggered by technical innovations (stapling devices or coagulation/dissecting devices), nowadays any type of gastrointestinal resection has been successfully performed laparoscopically and can be performed laparoscopically dependent on the patient's condition. This summary gives an overview over 30 years of laparoscopic surgery with focus on today's indications and evidence. Main indications remain the more common procedures, e.g., appendectomy, cholecystectomy, bariatric procedures or colorectal resections. For all these indications, the laparoscopic approach has become the gold standard with less perioperative morbidity. Regarding oncological outcome there have been several high-quality randomized controlled trials which demonstrated equivalency between laparoscopic and open colorectal resections. Less common procedures like esophagectomy, oncological gastrectomy, liver and pancreatic resections can be performed successfully as well by an experienced surgeon. However, the evidence for these special indications is poor and a general recommendation cannot be given. In conclusion, laparoscopic surgery has revolutionized the field of gastrointestinal surgery by reducing perioperative morbidity without disregarding surgical principles especially in oncological surgery.

  12. Ostomy Surgery of the Bowel

    Science.gov (United States)

    ... Digestive System & How it Works Zollinger-Ellison Syndrome Ostomy Surgery of the Bowel What is ostomy surgery of the bowel? Ostomy surgery of the ... of the body. Why does a person need ostomy surgery of the bowel? A person may need ...

  13. Telerobotic Surgery: An Intelligent Systems Approach to Mitigate the Adverse Effects of Communication Delay. Chapter 4

    Science.gov (United States)

    Cardullo, Frank M.; Lewis, Harold W., III; Panfilov, Peter B.

    2007-01-01

    An extremely innovative approach has been presented, which is to have the surgeon operate through a simulator running in real-time enhanced with an intelligent controller component to enhance the safety and efficiency of a remotely conducted operation. The use of a simulator enables the surgeon to operate in a virtual environment free from the impediments of telecommunication delay. The simulator functions as a predictor and periodically the simulator state is corrected with truth data. Three major research areas must be explored in order to ensure achieving the objectives. They are: simulator as predictor, image processing, and intelligent control. Each is equally necessary for success of the project and each of these involves a significant intelligent component in it. These are diverse, interdisciplinary areas of investigation, thereby requiring a highly coordinated effort by all the members of our team, to ensure an integrated system. The following is a brief discussion of those areas. Simulator as a predictor: The delays encountered in remote robotic surgery will be greater than any encountered in human-machine systems analysis, with the possible exception of remote operations in space. Therefore, novel compensation techniques will be developed. Included will be the development of the real-time simulator, which is at the heart of our approach. The simulator will present real-time, stereoscopic images and artificial haptic stimuli to the surgeon. Image processing: Because of the delay and the possibility of insufficient bandwidth a high level of novel image processing is necessary. This image processing will include several innovative aspects, including image interpretation, video to graphical conversion, texture extraction, geometric processing, image compression and image generation at the surgeon station. Intelligent control: Since the approach we propose is in a sense predictor based, albeit a very sophisticated predictor, a controller, which not only

  14. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control

    International Nuclear Information System (INIS)

    Machado, Rafael Henrique Szymanski; Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da

    2005-01-01

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99m Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  15. Systemic Lidocaine Does Not Attenuate Hepatic Dysfunction After Liver Surgery in Rats

    NARCIS (Netherlands)

    de Graaf, Wilmar; Diepenhorst, Gwen M. P.; Herroeder, Susanne; Erdogan, Deha; Hollmann, Markus W.; van Gulik, Thomas M.

    2012-01-01

    BACKGROUND: Lidocaine has been shown to attenuate ischemia-reperfusion (I/R) injury in the heart, lung, and brain, potentially due to modulation of inflammatory responses and apoptotic signaling pathways. Because hepatic I/R injury after liver surgery still poses a significant risk for postoperative

  16. Laparoscopic Upper Urinary System Surgery After Specialty Training: Presentation of 50 Cases

    Directory of Open Access Journals (Sweden)

    Alper Gok

    2014-03-01

    Full Text Available Aim: Results of first 50 laparoscopic upper urinary tractus surgeries which were performed in Adiyaman State Hospital during compulsory duty after specialty training are presented. Material and Method: Fifty patients who underwent laparoscopic upper urinary tractus surgeries in our clinic between February 2012 and January 2013 were retrospectively evaluated. All of the laparoscopic procedures were performed using transperitoneal method. Results: Mean age of the patients was 42,6±13,6 (17-74, and mean operation duration was 96,8±12,4 minutes (28-165. Thirty two patients were males and 18 were females. Intraoperative complications were not seen in any of the patients and operations didn%u2019t proceed to open surgeries. All patients were mobilized at first day after the operation. No patient needed opioids as painkillers at postoperative period. Decrease in hematocrit level was obseved in a patient at early postoperative period and this patient was followed conservatively with 6 units of erythrocyte suspension. Herniation from the port area was observed in a patient who had cortical cyst excision at postoperative 3rd month. No major complication was observed. Discussion: Laparoscopic surgery which is becoming more commonly used nowadays can be safely applied in state hospitals if appropriate infrastructure is provided.

  17. The spring balance: a simple monitoring system for fluid overload during hysteroscopic surgery

    NARCIS (Netherlands)

    Ankum, W. M.; Vonk, J.

    1994-01-01

    Fluid overload may arise during hysteroscopic surgery, caused by absorption of fluid used to distend the uterus. Continuous monitoring of the fluid balance is required to prevent this serious complication. Commercial equipment does not serve this purpose adequately. We describe a simple solution. We

  18. Virtual skeletal complex model- and landmark-guided orthognathic surgery system.

    Science.gov (United States)

    Lee, Sang-Jeong; Woo, Sang-Yoon; Huh, Kyung-Hoe; Lee, Sam-Sun; Heo, Min-Suk; Choi, Soon-Chul; Han, Jeong Joon; Yang, Hoon Joo; Hwang, Soon Jung; Yi, Won-Jin

    2016-05-01

    In this study, correction of the maxillofacial deformities was performed by repositioning bone segments to an appropriate location according to the preoperative planning in orthognathic surgery. The surgery was planned using the patient's virtual skeletal models fused with optically scanned three-dimensional dentition. The virtual maxillomandibular complex (MMC) model of the patient's final occlusal relationship was generated by fusion of the maxillary and mandibular models with scanned occlusion. The final position of the MMC was simulated preoperatively by planning and was used as a goal model for guidance. During surgery, the intraoperative registration was finished immediately using only software processing. For accurate repositioning, the intraoperative MMC model was visualized on the monitor with respect to the simulated MMC model, and the intraoperative positions of multiple landmarks were also visualized on the MMC surface model. The deviation errors between the intraoperative and the final positions of each landmark were visualized quantitatively. As a result, the surgeon could easily recognize the three-dimensional deviation of the intraoperative MMC state from the final goal model without manually applying a pointing tool, and could also quickly determine the amount and direction of further MMC movements needed to reach the goal position. The surgeon could also perform various osteotomies and remove bone interference conveniently, as the maxillary tracking tool could be separated from the MMC. The root mean square (RMS) difference between the preoperative planning and the intraoperative guidance was 1.16 ± 0.34 mm immediately after repositioning. After surgery, the RMS differences between the planning and the postoperative computed tomographic model were 1.31 ± 0.28 mm and 1.74 ± 0.73 mm for the maxillary and mandibular landmarks, respectively. Our method provides accurate and flexible guidance for bimaxillary orthognathic surgery based on

  19. Information technology in the strategy of digestive surgery. (2) Advances of CAD system using OsiriX

    International Nuclear Information System (INIS)

    Sugimoto, Maki; Yasuda, Hideki; Koda, Keiji; Yamazaki, Masato; Tezuka, Tohru; Kosugi, Chihiro; Watayo, Yoshihisa; Naka, Shuji

    2007-01-01

    OsiriX, one of information technology (IT) product in medicine, is an image processing system developed by surgeons and its software for Mac OS can be installed free of charge (http://homepage.mac.com/rossetantoine/osrix/). The present review describes the practical application of this computer-aided diagnostic (CAD) tool mainly in the field of surgery of hepato-biliary-pancreatic system. Authors are successfully utilizing the OsiriX for pre-operative diagnosis by modalities of multidetector-row CT (MDCT), MRI and PET images, for simulation of surgery by volume rendering, carbon dioxide MDCT cholangiopancreatography (CMCP), 3D vascular construction MDCT angiography and virtual reality, and for navigation during the actual operation. The machine they use is 16-row MDCT LightSpeed Ultra 16 (GE Healthcare), and their data are processed through the Digital Imaging and Communications in Medicine (DICOM) viewer OsiriX 2.6, Power Mac G5, MacBook Pro (Apple Computer, Inc.) and 3D image processing engine (TeraRecon, Inc.). Presented are details of decision of region of interest (ROI), 3D ROI extraction by region-growing, MacBook Pro and iPod, and IT surgery by OsiriX, which are still being improved day by day. (T.I.)

  20. Fiber optical sensor system for shape and haptics for flexible instruments in minimally invasive surgery: overview and status quo

    Science.gov (United States)

    Ledermann, Christoph; Pauer, Hendrikje; Woern, Heinz

    2014-05-01

    In minimally invasive surgery, exible mechatronic instruments promise to improve the overall performance of surgical interventions. However, those instruments require highly developed sensors in order to provide haptic feedback to the surgeon or to enable (semi-)autonomous tasks. Precisely, haptic sensors and a shape sensor are required. In this paper, we present our ber optical sensor system of Fiber Bragg Gratings, which consists of a shape sensor, a kinesthetic sensor and a tactile sensor. The status quo of each of the three sensors is described, as well as the concept to integrate them into one ber optical sensor system.

  1. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: A systemic review.

    Science.gov (United States)

    Fiani, Brian; Quadri, Syed A; Farooqui, Mudassir; Cathel, Alessandra; Berman, Blake; Noel, Jerry; Siddiqi, Javed

    2018-04-03

    Whenever any new technology is introduced into the healthcare system, it should satisfy all three pillars of the iron triangle of health care, which are quality, cost-effectiveness, and accessibility. There has been quite advancement in the field of spine surgery in the last two decades with introduction of new technological modalities such as CAN and surgical robotic devices. MAZOR SpineAssist/Renaissance was the first robotic system to be approved for the use in spine surgeries in the USA in 2004. In this review, the authors sought to determine if the current literature supports this technology to be cost-effective, accessible, and improve the quality of care for individuals and populations by increasing the likelihood of desired health outcomes. Robotic-assisted surgery seems to provide perfection in surgical ergonomics and surgical dexterity, consequently improving patient outcomes. A lot of data is present on the accuracy, effectiveness, and safety of the robotic-guided technology which reflects remarkable improvements in quality of care, making its utility convincingly undisputable. The technology has been claimed to be cost-effective but there seems to be lack of data in the literature on this topic to validate this claim. Apart from just the outcome parameters, there is an immense need of studies on real-time cost-efficacy, patient perspective, surgeon and resident learning curve, and their experience with this new technology. Furthermore, new studies looking into increased utilities of this technology, such as brain and spine tumor resection, deep brain stimulation procedures, and osteotomies in deformity surgery, might authenticate the cost of the equipment.

  2. Metabolic phenotype-microRNA data fusion analysis of the systemic consequences of Roux-en-Y gastric bypass surgery.

    Science.gov (United States)

    Wu, Q; Li, J V; Seyfried, F; le Roux, C W; Ashrafian, H; Athanasiou, T; Fenske, W; Darzi, A; Nicholson, J K; Holmes, E; Gooderham, N J

    2015-07-01

    Bariatric surgery offers sustained marked weight loss and often remission of type 2 diabetes, yet the mechanisms of establishment of these health benefits are not clear. We mapped the coordinated systemic responses of gut hormones, the circulating miRNAome and the metabolome in a rat model of Roux-en-Y gastric bypass (RYGB) surgery. The response of circulating microRNAs (miRNAs) to RYGB was striking and selective. Analysis of 14 significantly altered circulating miRNAs within a pathway context was suggestive of modulation of signaling pathways including G protein signaling, neurodegeneration, inflammation, and growth and apoptosis responses. Concomitant alterations in the metabolome indicated increased glucose transport, accelerated glycolysis and inhibited gluconeogenesis in the liver. Of particular significance, we show significantly decreased circulating miRNA-122 levels and a more modest decline in hepatic levels, following surgery. In mechanistic studies, manipulation of miRNA-122 levels in a cell model induced changes in the activity of key enzymes involved in hepatic energy metabolism, glucose transport, glycolysis, tricarboxylic acid cycle, pentose phosphate shunt, fatty-acid oxidation and gluconeogenesis, consistent with the findings of the in vivo surgery-mediated responses, indicating the powerful homeostatic activity of the miRNAs. The close association between energy metabolism, neuronal signaling and gut microbial metabolites derived from the circulating miRNA, plasma, urine and liver metabolite and gut hormone correlations further supports an enhanced gut-brain signaling, which we suggest is hormonally mediated by both traditional gut hormones and miRNAs. This transomic approach to map the crosstalk between the circulating miRNAome and metabolome offers opportunities to understand complex systems biology within a disease and interventional treatment setting.

  3. Clinical Application of Different Surgical Navigation Systems in Complex Craniomaxillofacial Surgery: The Use of Multisurface 3-Dimensional Images and a 2-Plane Reference System.

    Science.gov (United States)

    Liu, Tom J; Ko, An-Ta; Tang, Yueh-Bih; Lai, Hong-Shiee; Chien, Hsiung-Fei; Hsieh, Thomas Mon-Hsian

    2016-04-01

    Intraoperative navigation is a tool that provides surgeons with real-time guidance based on patients' preoperative imaging studies. The application of intraoperative navigation to neurosurgery and otolaryngology has been well documented; however, only isolated reports have analyzed its potential in the field of craniomaxillofacial surgery. From November 2010 to July 2014, 15 patients were operated on for complex craniomaxillofacial surgery with assistance by 3 different navigation systems, which used either infrared or electromagnetic technologies. We imported fine-cut (0.625-mm) computed tomographic scan images of the patients to the navigation systems whose software processed them into multisurface 3-dimentional models used as guiding material for the surgical navigation. We also developed a simple "2-plane reference system" to ensure that the final results were symmetric to the normal half of the face. Appearance outcome was evaluated by questionnaire. Of these 15 cases, 3 cases were performed with infrared-based navigation, and the remaining 12 cases were accomplished by electromagnetic technology. Most of these cases resulted in satisfactory outcomes after tumor resection, posttraumatic reconstruction, and postablative reconstruction. Navigation systems offer highly valuable intraoperative assistance in complex craniomaxillofacial surgery. Not only can these systems pinpoint deep-seated lesions as neurosurgeons or otolaryngologists do, but they can also use a simple 2-plane reference system for accurate bone alignment. Moreover, advancements in multisurface 3-D models provide us more reliable intuitive image guidance. The application of electromagnetic technology, with its smaller reference obviation of the line-of-sight problem, makes the manipulation of craniomaxillofacial surgery more comfortable.

  4. A Comparison of Different Operating Systems for Femtosecond Lasers in Cataract Surgery.

    Science.gov (United States)

    Wu, B M; Williams, G P; Tan, A; Mehta, J S

    2015-01-01

    The introduction of femtosecond lasers is potentially a major shift in the way we approach cataract surgery. The development of increasingly sophisticated intraocular lenses (IOLs), coupled with heightened patient expectation of high quality postsurgical visual outcomes, has generated the need for a more precise, highly reproducible and standardized method to carry out cataract operations. As femtosecond laser-assisted cataract surgery (FLACS) becomes more commonplace in surgical centers, further evaluation of the potential risks and benefits needs to be established, particularly in the medium/long term effects. Healthcare administrators will also have to weigh and balance out the financial costs of these lasers relative to the advantages they put forth. In this review, we provide an operational overview of three of five femtosecond laser platforms that are currently commercially available: the Catalys (USA), the Victus (USA), and the LDV Z8 (Switzerland).

  5. Performance of European system for cardiac operative risk evaluation in Veterans General Hospital Kaohsiung cardiac surgery

    Directory of Open Access Journals (Sweden)

    Hsin-Hung Shih

    2011-03-01

    Conclusion: EuroSCORE is simple and easy to use. In the present study, the model demonstrated excellent accuracy in all and various surgical subgroups in VGHKS cardiovascular surgery populations. Good calibration ability in all and different risk categories was identified except for isolated CABG group. Recalibration factors of 0.55 and 0.85 were suggested for the various operative subgroups and risk categories.

  6. Strengthening Health Systems of Developing Countries: Inclusion of Surgery in Universal Health Coverage.

    Science.gov (United States)

    Okoroh, Juliet S; Chia, Victoria; Oliver, Emily A; Dharmawardene, Marisa; Riviello, Robert

    2015-08-01

    Universal health coverage (UHC) has its roots in the Universal Declaration of Human Rights and has recently gained momentum. Out-of-pocket payments (OPP) remain a significant barrier to care. There is an increasing global prevalence of non-communicable diseases, many of which are surgically treatable. We sought to provide a comparative analysis of the inclusion of surgical care in operating plans for UHC in low- and middle-income countries (LMIC). We systematically searched PubMed and Google Scholar using pre-defined criteria for articles published in English, Spanish, or French between January 1991 and November 2013. Keywords included "insurance," "OPP," "surgery," "trauma," "cancer," and "congenital anomalies." World Health Organization (WHO), World Bank, and Joint Learning Network for UHC websites were searched for supporting documents. Ministries of Health were contacted to provide further information on the inclusion of surgery. We found 696 articles and selected 265 for full-text review based on our criteria. Some countries enumerated surgical conditions in detail (India, 947 conditions). Other countries mentioned surgery broadly. Obstetric care was most commonly covered (19 countries). Solid organ transplantation was least covered. Cancer care was mentioned broadly, often without specifying the therapeutic modality. No countries were identified where hospitals are required to provide emergency care regardless of insurance coverage. OPP varied greatly between countries. Eighty percent of countries had OPP of 60% or more, making these services, even if partially covered, largely inaccessible. While OPP, delivery, and utilization continue to represent challenges to health care access in many LMICs, the inclusion of surgery in many UHC policies sets an important precedent in addressing a growing global prevalence of surgically treatable conditions. Barriers to access, including inequalities in financial protection in the form of high OPP, remain a fundamental

  7. Global Surgery System Strengthening: It Is All About the Right Metrics.

    Science.gov (United States)

    Watters, David A; Guest, Glenn D; Tangi, Viliami; Shrime, Mark G; Meara, John G

    2018-04-01

    Progress in achieving "universal access to safe, affordable surgery, and anesthesia care when needed" is dependent on consensus not only about the key messages but also on what metrics should be used to set goals and measure progress. The Lancet Commission on Global Surgery not only achieved consensus on key messages but also recommended 6 key metrics to inform national surgical plans and monitor scale-up toward 2030. These metrics measure access to surgery, as well as its timeliness, safety, and affordability: (1) Two-hour access to the 3 Bellwether procedures (cesarean delivery, emergency laparotomy, and management of an open fracture); (2) Surgeon, Anesthetist, and Obstetrician workforce >20/100,000; (3) Surgical volume of 5000 procedures/100,000; (4) Reporting of perioperative mortality rate; and (5 and 6) Risk rates of catastrophic expenditure and impoverishment when requiring surgery. This article discusses the definition, validity, feasibility, relevance, and progress with each of these metrics. The authors share their experience of introducing the metrics in the Pacific and sub-Saharan Africa. We identify appropriate messages for each potential stakeholder-the patients, practitioners, providers (health services and hospitals), public (community), politicians, policymakers, and payers. We discuss progress toward the metrics being included in core indicator lists by the World Health Organization and the World Bank and how they have been, or may be, used to inform National Surgical Plans in low- and middle-income countries to scale-up the delivery of safe, affordable, and timely surgical and anesthesia care to all who need it.

  8. Outcomes of cataract surgery with residents as primary surgeons in the Veterans Affairs Healthcare System.

    Science.gov (United States)

    Payal, Abhishek R; Gonzalez-Gonzalez, Luis A; Chen, Xi; Cakiner-Egilmez, Tulay; Chomsky, Amy; Baze, Elizabeth; Vollman, David; Lawrence, Mary G; Daly, Mary K

    2016-03-01

    To explore visual outcomes, functional visual improvement, and events in resident-operated cataract surgery cases. Veterans Affairs Ophthalmic Surgery Outcomes Database Project across 5 Veterans Affairs Medical Centers. Retrospective data analysis of deidentified data. Cataract surgery cases with residents as primary surgeons were analyzed for logMAR corrected distance visual acuity (CDVA) and vision-related quality of life (VRQL) measured by the modified National Eye Institute Vision Function Questionnaire and 30 intraoperative and postoperative events. In some analyses, cases without events (Group A) were compared with cases with events (Group B). The study included 4221 cataract surgery cases. Preoperative to postoperative CDVA improved significantly in both groups (P < .0001), although the level of improvement was less in Group B (P = .03). A CDVA of 20/40 or better was achieved in 96.64% in Group A and 88.25% in Group B (P < .0001); however, Group B had a higher prevalence of preoperative ocular comorbidities (P < .0001). Cases with 1 or more events were associated with a higher likelihood of a postoperative CDVA worse than 20/40 (odds ratio, 3.82; 95% confidence interval, 2.92-5.05; P < .0001) than those who did not experience an event. Both groups had a significant increase in VRQL from preoperative levels (both P < .0001); however, the level of preoperative to postoperative VRQL improvement was significantly less in Group B (P < .0001). Resident-operated cases with and without events had an overall significant improvement in visual acuity and visual function compared with preoperatively, although this improvement was less marked in those that had an event. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  9. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  10. Analysis of Surgical Site Infection after Musculoskeletal Tumor Surgery: Risk Assessment Using a New Scoring System

    Directory of Open Access Journals (Sweden)

    Satoshi Nagano

    2014-01-01

    Full Text Available Surgical site infection (SSI has not been extensively studied in musculoskeletal tumors (MST owing to the rarity of the disease. We analyzed incidence and risk factors of SSI in MST. SSI incidence was evaluated in consecutive 457 MST cases (benign, 310 cases and malignant, 147 cases treated at our institution. A detailed analysis of the clinical background of the patients, pre- and postoperative hematological data, and other factors that might be associated with SSI incidence was performed for malignant MST cases. SSI occurred in 0.32% and 12.2% of benign and malignant MST cases, respectively. The duration of the surgery (P=0.0002 and intraoperative blood loss (P=0.0005 was significantly more in the SSI group than in the non-SSI group. We established the musculoskeletal oncological surgery invasiveness (MOSI index by combining 4 risk factors (blood loss, operation duration, preoperative chemotherapy, and the use of artificial materials. The MOSI index (0–4 points score significantly correlated with the risk of SSI, as demonstrated by an SSI incidence of 38.5% in the group with a high score (3-4 points. The MOSI index score and laboratory data at 1 week after surgery could facilitate risk evaluation and prompt diagnosis of SSI.

  11. Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system.

    Science.gov (United States)

    Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro

    2018-05-01

    The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.

  12. Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract surgery.

    Science.gov (United States)

    Peng, Jie; Zhang, Qi; Jin, Hai-Ying; Lu, Wu-Yi; Zhao, Pei-Quan

    2016-01-01

    To compare the results of non-mydriatic ultra-wide field imaging system, mydriatic slit-lamp lens (Volk +90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery. Non-mydriatic images were obtained with an Optomap panoramic 200Tx (Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist. A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day. A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens. In total, 160 patients (184 eyes) were examined, and 66, 69, and 75 cases of retinal lesion(s) were identified using the Optomap 200Tx, slit-lamp lens, and Goldmann three-mirror contact lens, respectively. In 13 cases, fundus changes were sight-threatening. The results obtained by Optomap 200Tx examination and by mydriatic slit-lamp lens examination have good consistency (P=0.375, Kappa=0.942). The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx (P=0.004, Kappa=0.897) and mydriatic slit-lamp lens examination (P=0.031, Kappa=0.932). Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss. Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.

  13. Early experience with the da Vinci® surgical system robot in gynecological surgery at King Abdulaziz University Hospital

    Directory of Open Access Journals (Sweden)

    Sait KH

    2011-07-01

    Full Text Available Khalid H SaitObstetrics and Gynecology Department, Faculty of Medicine, Gynecology Oncology Unit, King Abdulaziz University Hospital, Jeddah, Saudi ArabiaBackground: The purpose of this study was to review our experience and the challenges of using the da Vinci® surgical system robot during gynecological surgery at King Abdulaziz University Hospital.Methods: A retrospective study was conducted to review all cases of robot-assisted gynecologic surgery performed at our institution between January 2008 and December 2010. The patients were reviewed for indications, complications, length of hospital stay, and conversion rate, as well as console and docking times.Results: Over the three-year period, we operated on 35 patients with benign or malignant conditions using the robot for a total of 62 surgical procedures. The docking times averaged seven minutes. The mean console times for simple hysterectomy, bilateral salpingo-oophorectomy, and bilateral pelvic lymphadenectomy were 125, 47, and 62 minutes, respectively. In four patients, laparoscopic procedures were converted to open procedures, giving a conversion rate of 6.5%. All of the conversions were among the first 15 procedures performed. The average hospital stay was 3 days. Complications occurred in five patients (14%, and none were directly related to the robotic system.Conclusion: Our early experience with the robot show that with proper training of the robotic team, technical difficulty with the robotic system is limited. There is definitely a learning curve that requires performance of gynecological surgical procedures using the robot.Keywords: da Vinci robot, gynecological surgery, laparoscopy

  14. Error reporting from the da Vinci surgical system in robotic surgery: A Canadian multispecialty experience at a single academic centre.

    Science.gov (United States)

    Rajih, Emad; Tholomier, Côme; Cormier, Beatrice; Samouëlian, Vanessa; Warkus, Thomas; Liberman, Moishe; Widmer, Hugues; Lattouf, Jean-Baptiste; Alenizi, Abdullah M; Meskawi, Malek; Valdivieso, Roger; Hueber, Pierre-Alain; Karakewicz, Pierre I; El-Hakim, Assaad; Zorn, Kevin C

    2017-05-01

    The goal of the study is to evaluate and report on the third-generation da Vinci surgical (Si) system malfunctions. A total of 1228 robotic surgeries were performed between January 2012 and December 2015 at our academic centre. All cases were performed by using a single, dual console, four-arm, da Vinci Si robot system. The three specialties included urology, gynecology, and thoracic surgery. Studied outcomes included the robotic surgical error types, immediate consequences, and operative side effects. Error rate trend with time was also examined. Overall robotic malfunctions were documented on the da Vinci Si systems event log in 4.97% (61/1228) of the cases. The most common error was related to pressure sensors in the robotic arms indicating out of limit output. This recoverable fault was noted in 2.04% (25/1228) of cases. Other errors included unrecoverable electronic communication-related in 1.06% (13/1228) of cases, failed encoder error in 0.57% (7/1228), illuminator-related in 0.33% (4/1228), faulty switch in 0.24% (3/1228), battery-related failures in 0.24% (3/1228), and software/hardware error in 0.08% (1/1228) of cases. Surgical delay was reported only in one patient. No conversion to either open or laparoscopic occurred secondary to robotic malfunctions. In 2015, the incidence of robotic error rose to 1.71% (21/1228) from 0.81% (10/1228) in 2014. Robotic malfunction is not infrequent in the current era of robotic surgery in various surgical subspecialties, but rarely consequential. Their seldom occurrence does not seem to affect patient safety or surgical outcome.

  15. Qualitative and quantitative outcomes of audience response systems as an educational tool in a plastic surgery residency program.

    Science.gov (United States)

    Arneja, Jugpal S; Narasimhan, Kailash; Bouwman, David; Bridge, Patrick D

    2009-12-01

    In-training evaluations in graduate medical education have typically been challenging. Although the majority of standardized examination delivery methods have become computer-based, in-training examinations generally remain pencil-paper-based, if they are performed at all. Audience response systems present a novel way to stimulate and evaluate the resident-learner. The purpose of this study was to assess the outcomes of audience response systems testing as compared with traditional testing in a plastic surgery residency program. A prospective 1-year pilot study of 10 plastic surgery residents was performed using audience response systems-delivered testing for the first half of the academic year and traditional pencil-paper testing for the second half. Examination content was based on monthly "Core Quest" curriculum conferences. Quantitative outcome measures included comparison of pretest and posttest and cumulative test scores of both formats. Qualitative outcomes from the individual participants were obtained by questionnaire. When using the audience response systems format, pretest and posttest mean scores were 67.5 and 82.5 percent, respectively; using traditional pencil-paper format, scores were 56.5 percent and 79.5 percent. A comparison of the cumulative mean audience response systems score (85.0 percent) and traditional pencil-paper score (75.0 percent) revealed statistically significantly higher scores with audience response systems (p = 0.01). Qualitative outcomes revealed increased conference enthusiasm, greater enjoyment of testing, and no user difficulties with the audience response systems technology. The audience response systems modality of in-training evaluation captures participant interest and reinforces material more effectively than traditional pencil-paper testing does. The advantages include a more interactive learning environment, stimulation of class participation, immediate feedback to residents, and immediate tabulation of results for the

  16. Systemic Chemotherapy using FLOT - Regimen Combined with Cytoreductive Surgery plus HIPEC for Treatment of Peritoneal Metastasized Gastric Cancer. .

    Science.gov (United States)

    Müller, H; Hotopp, Th; Tofeili, A; Wutke, K

    2014-05-01

    The aim was to evaluate the feasibility and the effectiveness of neoadjuvant systemic chemotherapy using FLOT - protocol followed by cytoreductive surgery (CRS), hyperthermic intraperitoneal chemotherapy (HIPEC) followed by systemic chemotherapyand in patients with peritoneal carciriomatosis (PC) from gastric cancer. Twenty six (median age 53 years, range 39 - 71) were scheduled for three cycles of neoadjuvant systemic chemotherapy using bi-weekly FLOT - protocol followed by CRS + HIPEC. Thereafter 3 additional cycles of FLOT were given. During HIPEC in Colliseum technique Oxaliplatin was given in a dosage of 200 mg/m2 and Docetaxel in a dosage of 80 mg/m2. All patients underwent cytoreductive surgery plus HIPEC. Peritoneal Cancer index was > 15 in 3 cases only. Complete resection could be carried out in all cases (CC-O 18, CC-18). Postoperative complication rate was 23% with no mortality within 30 days. Anastomotic leakage rate was 3.2%. Overall survival was 19.0 months with a 2-year survival rate 38%. Regression analysis demonstrated a Peritoneal Cancer Index PCI > 12 as negative factor for survival. Neoadju- vant chemotherapy using FLOT - protocol followed by CRS + HIPEC seems to be associated with prolonged OS in patients with peritoneal carcinomatosis from gastric cancer. This treatment is not recommended for patients with extensive peritoneal involvement and PCI > 12.

  17. [Quality of service provided to heart surgery patients of the Unified Health System-SUS].

    Science.gov (United States)

    Borges, Juliana Bassalobre Carvalho; Carvalho, Sebastião Marcos Ribeiro de; Silva, Marcos Augusto de Moraes

    2010-01-01

    To evaluate the service quality provided to heart surgery patients during their hospital stay, identifying the patient's expectations and perceptions. To associate service quality with: gender, age and the use of extracorporeal circulation. We studied 82 elective heart surgery patients (52.4% females and 47.6% males), operated by midsternal thoracotomy, age: 31 to 83 years (60.4 +/- 13.2 years); period: March to September 2006. Service quality was evaluated in two instances: the expectations at pre-operative and the perceptions of the service received on the 6th post-operative; through the application of the modified SERVQUAL scale (SERVQUAL-Card). The result was obtained by the difference of the sum of the scores on perception minus those of the expectations, and through statistical analysis. The SERVQUAL-Card scale was statistically validated, showing adequate level of internal consistency. We found a higher frequency of myocardial revascularization 55 (67.0%); first heart surgery 72 (87.8%) and the use of ECC 69 (84.1%). We noticed high mean values for expectations and perceptions with significant results (Pquality of service with: gender, in empathy (P= 0.04) and age, in reliability (P = 0.02). There was no significant association between ECC and quality of service. Service quality was satisfactory. The patient demonstrated a high expectation to hospital medical service. Women present a higher perception of quality in empathy and younger people in reliability. The use of ECC is not related to service quality in this sample. The data obtained in this study suggest that the quality of this health service can be monitored through the periodical application of the SERVQUAL scale.

  18. S3 guidelines for intensive care in cardiac surgery patients: hemodynamic monitoring and cardiocirculary system

    Directory of Open Access Journals (Sweden)

    Schmitt, D. V.

    2010-01-01

    Full Text Available Hemodynamic monitoring and adequate volume-therapy, as well as the treatment with positive inotropic drugs and vasopressors are the basic principles of the postoperative intensive care treatment of patient after cardiothoracic surgery. The goal of these S3 guidelines is to evaluate the recommendations in regard to evidence based medicine and to define therapy goals for monitoring and therapy. In context with the clinical situation the evaluation of the different hemodynamic parameters allows the development of a therapeutic concept and the definition of goal criteria to evaluate the effect of treatment. Up to now there are only guidelines for subareas of postoperative treatment of cardiothoracic surgical patients, like the use of a pulmonary artery catheter or the transesophageal echocardiography. The German Society for Thoracic and Cardiovascular Surgery (Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie, DGTHG and the German Society for Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin, DGAI made an approach to ensure and improve the quality of the postoperative intensive care medicine after cardiothoracic surgery by the development of S3 consensus-based treatment guidelines. Goal of this guideline is to assess the available monitoring methods with regard to indication, procedures, predication, limits, contraindications and risks for use. The differentiated therapy of volume-replacement, positive inotropic support and vasoactive drugs, the therapy with vasodilatators, inodilatators and calcium sensitizers and the use of intra-aortic balloon pumps will also be addressed. The guideline has been developed following the recommendations for the development of guidelines by the Association of the Scientific Medical Societies in Germany (AWMF. The presented key messages of the guidelines were approved after two consensus meetings under the moderation of the Association of the

  19. Method, apparatus, and system for utilizing augmented reality to improve surgery

    KAUST Repository

    Cali, Corrado

    2016-10-13

    A method, apparatus, and computer readable medium are provided for utilizing augmented reality visualization to assist surgery. An example method includes generating a three dimensional reconstruction of an image stack representing a target area of a patient, and superimposing, by a head-mounted display, a projection of the three dimensional reconstruction onto a field of view of a user. The method further includes maintaining alignment between the projection and the user\\'s actual view of the target area using a plurality of fiducial markers associated with the target area. In some embodiments, the method further includes scanning the target area to generate the image stack.

  20. Support for total hip replacement surgery: Structures modeling, Gait Data Analysis and Report system

    Directory of Open Access Journals (Sweden)

    Gianluca Mario Izzo

    2012-03-01

    Full Text Available For the treatment of advanced damages of hip joints, Total Hip Arthroplasty is well proven. Due to the different mechanical properties of the prosthesis material and the bone tissue, a partial unloading of the periprosthetic bone occurs. The bone cement causes reduction in bone density as a result of removal of normal stress from the bone, leading to weakening of the bone in that area and the fracture risk increases. Bone loss is identified as one of the main reasons for loosening of the stem. Otherwise, thanks to the press-fit of the non-cemented stem achieved by surgery, the bone layers immediately adjacent to the stem are preloaded, thus encouraged growing, and the bone getting stronger. The non-cemented stem would be the better choice for every patient, but the question remains if the femur can handle the press- fitting surgery. This studies aim to develop a monitoring techniques based on Gait analysis and bone density changes to assess patient recovery after Total Hip Arthroplasty. Furthermore, to validate computational processes based on 3D modeling and Finite Element Methods for optimizing decision making in the operation process and selecting the suited surgical procedure. A vision could be minimizing risk of periprosthetic fracture during and after surgery. Patients: The sample presents 11 patients receiving cemented implant and 13 for the uncemented. Patients are grouped by type of implant. Three checkpoints were considered: before, after operation and one year later. CT scans, gaitrite and kinepro measurements have been realized. Main outcome measures: Fracture risk probability is higher in bone with low bone mineral density; therefore bones are more fragile in elderly people. BMD is indeed one parameter considered among all the observations. Periprosthetic fracture of the femur is a rare but complex complication of THA, and requires demanding surgery. As such, they result in considerable morbidity and dysfunction. Thus, tests of

  1. Enhanced Recovery After Surgery Program Implementation in 2 Surgical Populations in an Integrated Health Care Delivery System.

    Science.gov (United States)

    Liu, Vincent X; Rosas, Efren; Hwang, Judith; Cain, Eric; Foss-Durant, Anne; Clopp, Molly; Huang, Mengfei; Lee, Derrick C; Mustille, Alex; Kipnis, Patricia; Parodi, Stephen

    2017-07-19

    Novel approaches to perioperative surgical care focus on optimizing nutrition, mobility, and pain management to minimize adverse events after surgical procedures. To evaluate the outcomes of an enhanced recovery after surgery (ERAS) program among 2 target populations: patients undergoing elective colorectal resection and patients undergoing emergency hip fracture repair. A pre-post difference-in-differences study before and after ERAS implementation in the target populations compared with contemporaneous surgical comparator groups (patients undergoing elective gastrointestinal surgery and emergency orthopedic surgery). Implementation began in February and March 2014 and concluded by the end of 2014 at 20 medical centers within the Kaiser Permanente Northern California integrated health care delivery system. A multifaceted ERAS program designed with a particular focus on perioperative pain management, mobility, nutrition, and patient engagement. The primary outcome was hospital length of stay. Secondary outcomes included hospital mortality, home discharge, 30-day readmission rates, and complication rates. The study included a total of 3768 patients undergoing elective colorectal resection (mean [SD] age, 62.7 [14.1] years; 1812 [48.1%] male) and 5002 patients undergoing emergency hip fracture repair (mean [SD] age, 79.5 [11.8] years; 1586 [31.7%] male). Comparator surgical patients included 5556 patients undergoing elective gastrointestinal surgery and 1523 patients undergoing emergency orthopedic surgery. Most process metrics had significantly greater changes in the ERAS target populations after implementation compared with comparator surgical populations, including those for ambulation, nutrition, and opioid use. Hospital length of stay and postoperative complication rates were also significantly lower among ERAS target populations after implementation. The rate ratios for postoperative complications were 0.68 (95% CI, 0.46-0.99; P = .04) for patients

  2. Robotic surgery

    Science.gov (United States)

    ... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...

  3. Nose Surgery

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  4. After Surgery

    Science.gov (United States)

    ... side effects. There is usually some pain with surgery. There may also be swelling and soreness around ... the first few days, weeks, or months after surgery. Some other questions to ask are How long ...

  5. Does adjuvant systemic therapy contribute to decrease of breast recurrence after breast-conserving surgery?

    International Nuclear Information System (INIS)

    Nishimura, Reiki; Matsuda, Masakazu; Okazaki, Shinji; Kai, K.; Hiyoshi, Y.

    2005-01-01

    Preventing breast recurrence after breast-conserving surgery is an important issue. The main factors contributing to breast recurrences are positive margins and absence of radiotherapy. In late years a standard adjuvant treatment is widely used in Japan. We examined whether these standard treatments contributed to reduction of a breast recurrence. By March 2003, 845 patients were treated by breast-conserving surgery, and the cases were divided into two groups by operation period; 426 cases until 1998 (the first half group) and 202 patients with follow-up periods more than 2 years (the latter group). There were much positive margins and patients with radiotherapy in a latter group in background factor. An endocrine therapy for estrogen receptor (ER) positive was performed in 68.1% in first half period, and in contrast 94.2% in the latter period, and chemotherapy was performed in 87% (mainly Epirubicin) for ER negative in the latter period, and 77% (mainly oral agent) in the first half period. There was a significant difference of breast recurrence-free survival between 2 groups; an early recurrence was seen in 19 cases (4.5%) in the first half period and 2 cases (1.0%) in the latter group. In particular the difference was significant in patients with absence of radiotherapy or negative ER. Multivariate analysis revealed that the operation time was a significant factor for breast recurrence. In conclusion, an apparent reduction of breast recurrence may be brought by a standard adjuvant therapy. (authors)

  6. Scalar position in cochlear implant surgery and outcome in residual hearing and the vestibular system.

    Science.gov (United States)

    Nordfalk, Karl Fredrik; Rasmussen, Kjell; Hopp, Einar; Greisiger, Ralf; Jablonski, Greg Eigner

    2014-02-01

    To evaluate the effect of the intracochlear electrode position on the residual hearing and VNG- and cVEMP responses. Prospective pilot study. Thirteen adult patients who underwent unilateral cochlear implant surgery were examined with high-resolution rotational tomography after cochlear implantation. All subjects were also tested with VNG, and 12 of the subjects were tested with cVEMP and audiometry before and after surgery. We found that although the electrode was originally planned to be positioned inside the scala tympani, only 8 of 13 had full insertion into the scala tympani. Loss of cVEMP response occurred to the same extent in the group with full scala tympani positioning and the group with scala vestibuli involvement. There was a non-significant difference in the loss of caloric response and residual hearing between the two groups. Interscalar dislocation of the electrode inside the cochlea was observed in two patients. A higher loss of residual hearing could be seen in the group with electrode dislocation between the scalae. Our findings indicate that intracochlear electrode dislocation is a possible cause to loss of residual hearing during cochlear implantation but cannot be the sole cause of postoperative vestibular loss.

  7. Pro con debate: the use of regional vs systemic analgesia for neonatal surgery.

    Science.gov (United States)

    Bösenberg, Adrian T; Jöhr, Martin; Wolf, Andrew R

    2011-12-01

    In recent years the inclusion of regional techniques to pediatric anesthesia has transformed practice. Simple procedures such as caudal anesthesia with local anaesthetics can reduce the amounts of general anesthesia required and provide complete analgesia in the postoperative period while avoiding large amounts of opioid analgesia with potential side effects that can impair recovery. However, the application of central blocks (epidural and spinal local anesthesia) via catheters in the younger infant, neonate and even preterm neonate remains more controversial. The potential for such invasive maneuvers themselves to augment risk, can be argued to outweigh the benefits, others would argue that epidural analgesia can reduce the need for postoperative ventilation and that this not only facilitates surgery when intensive care facilities are limited, but also reduces cost in terms of PICU stay and recovery profile. Currently, opinions are divided and strongly held with some major units adopting this approach widely and others maintaining a more conservative stance to anesthesia for major neonatal surgery. In this pro-con debate the evidence base is examined, supplemented with expert opinion to try to provide a balanced overall view. © 2011 Blackwell Publishing Ltd.

  8. The R.I.R.S. scoring system: An innovative scoring system for predicting stone-free rate following retrograde intrarenal surgery.

    Science.gov (United States)

    Xiao, Yinglong; Li, Deng; Chen, Lei; Xu, Yaoting; Zhang, Dingguo; Shao, Yi; Lu, Jun

    2017-11-21

    To establish and internally validate an innovative R.I.R.S. scoring system that allows urologists to preoperatively estimate the stone-free rate (SFR) after retrograde intrarenal surgery (RIRS). This study included 382 eligible samples from a total 573 patients who underwent RIRS from January 2014 to December 2016. Four reproducible factors in the R.I.R.S. scoring system, including renal stone density, inferior pole stone, renal infundibular length and stone burden, were measured based on preoperative computed tomography of urography to evaluate the possibility of stone clearance after RIRS. The median cumulative diameter of the stones was 14 mm, and the interquartile range was 10 to 21. The SFR on postoperative day 1 in the present cohort was 61.5% (235 of 382), and the final SFR after 1 month was 73.6% (281 of 382). We established an innovative scoring system to evaluate SFR after RIRS using four preoperative characteristics. The range of the R.I.R.S. scoring system was 4 to 10. The overall score showed a great significance of stone-free status (p R.I.R.S. scoring system was 0.904. The R.I.R.S. scoring system is associated with SFR after RIRS. This innovative scoring system can preoperatively assess treatment success after intrarenal surgery and can be used for preoperative surgical arrangement and comparisons of outcomes among different centers and within a center over time.

  9. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  10. The pedicle screw-rod system is an acceptable method of reconstructive surgery after resection of sacroiliac joint tumours

    Directory of Open Access Journals (Sweden)

    Yi-Jun Zhou

    2016-03-01

    Full Text Available Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two, sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study.

  11. Investigations on the potential of a low power diode pumped Er:YAG laser system for oral surgery

    Science.gov (United States)

    Stock, Karl; Wurm, Holger; Hausladen, Florian; Wagner, Sophia; Hibst, Raimund

    2015-02-01

    Flash lamp pumped Er:YAG-lasers are used in clinical practice for dental applications successfully. As an alternative, several diode pumped Er:YAG laser systems (Pantec Engineering AG) become available, with mean laser power of 2W, 15W, and 30W. The aim of the presented study is to investigate the potential of the 2W Er:YAG laser system for oral surgery. At first an appropriate experimental set-up was realized with a beam delivery and both, a focusing unit for non-contact tissue cutting and a fiber tip for tissue cutting in contact mode. In order to produce reproducible cuts, the samples (porcine gingiva) were moved by a computer controlled translation stage. On the fresh samples cutting depth and quality were determined by light microscopy. Afterwards histological sections were prepared and microscopically analyzed regarding cutting depth and thermal damage zone. The experiments show that low laser power ≤ 2W is sufficient to perform efficient oral soft tissue cutting with cut depth up to 2mm (sample movement 2mm/s). The width of the thermal damage zone can be controlled by the irradiation parameters within a range of about 50μm to 110μm. In general, thermal injury is more pronounced using fiber tips in contact mode compared to the focused laser beam. In conclusion the results reveal that even the low power diode pumped Er:YAG laser is an appropriate tool for oral surgery.

  12. Identifying Natural Alignments Between Ambulatory Surgery Centers and Local Health Systems: Building Broader Communities of Surgical Care.

    Science.gov (United States)

    Funk, Russell J; Owen-Smith, Jason; Landon, Bruce E; Birkmeyer, John D; Hollingsworth, John M

    2017-02-01

    To develop and compare methods for identifying natural alignments between ambulatory surgery centers (ASCs) and hospitals that anchor local health systems. Using all-payer data from Florida's State Ambulatory Surgery and Inpatient Databases (2005-2009), we developed 3 methods for identifying alignments between ASCS and hospitals. The first, a geographic proximity approach, used spatial data to assign an ASC to its nearest hospital neighbor. The second, a predominant affiliation approach, assigned an ASC to the hospital with which it shared a plurality of surgeons. The third, a network community approach, linked an ASC with a larger group of hospitals held together by naturally occurring physician networks. We compared each method in terms of its ability to capture meaningful and stable affiliations and its administrative simplicity. Although the proximity approach was simplest to implement and produced the most durable alignments, ASC surgeon's loyalty to the assigned hospital was low with this method. The predominant affiliation and network community approaches performed better and nearly equivalently on these metrics, capturing more meaningful affiliations between ASCs and hospitals. However, the latter's alignments were least durable, and it was complex to administer. We describe 3 methods for identifying natural alignments between ASCs and hospitals, each with strengths and weaknesses. These methods will help health system managers identify ASCs with which to partner. Moreover, health services researchers and policy analysts can use them to study broader communities of surgical care.

  13. External validation of the endometriosis fertility index (EFI) staging system for predicting non-ART pregnancy after endometriosis surgery.

    Science.gov (United States)

    Tomassetti, C; Geysenbergh, B; Meuleman, C; Timmerman, D; Fieuws, S; D'Hooghe, T

    2013-05-01

    Can the ability of the endometriosis fertility index (EFI) to predict non-assisted reproductive technology (ART) pregnancy after endometriosis surgery be confirmed by an external validation study? The significant relationship between the EFI score and the time to non-ART pregnancy observed in our study represents an external validation of this scoring system. The EFI was previously developed and tested prospectively in a single center, but up to now no external validation has been published. Our data provide validation of the EFI in an external fertility unit on a robust scientific basis, to identify couples with a good prognosis for spontaneous conception who can therefore defer ART treatment, regardless of their revised American Fertility Society (rAFS) endometriosis staging. Retrospective cohort study where the EFI was calculated based on history and detailed surgical findings, and related to pregnancy outcome in 233 women attempting non-ART conception immediately after surgery; all data used for EFI calculation and analysis of reproductive outcome had been collected prospectively as part of another study. The EFI score was calculated (score 0-10) for 233 women with all rAFS endometriosis stages (minimal-mild, n = 75; moderate-severe, n = 158) after endometriosis surgery (1 September 2006-30 September 2010) in a university hospital-based reproductive medicine unit with combined expertise in reproductive surgery and medically assisted reproduction. All participants attempted non-ART conception immediately after surgery by natural intercourse, ovulation induction with timed intercourse or intrauterine insemination (with or without ovulation induction or controlled ovarian stimulation). All analyses were performed for three different definitions of pregnancy [overall (any HCG >25 IU/l), clinical and ongoing >20 weeks]. Six groups were distinguished (EFI scores 1-3, 4, 5, 6, 7+8, 9+10), and Kaplan-Meier (K-M) estimates for cumulative pregnancy rate were calculated

  14. Shape memory alloy fixator system for suturing tissue in minimal access surgery.

    Science.gov (United States)

    Xu, W; Frank, T G; Stockham, G; Cuschieri, A

    1999-01-01

    A new technique for suturing human tissue is described in which tissue closure is achieved by means of small fixators made from shape memory alloy. The aim of the development is to provide an alternative to thread suturing in minimal access surgery, which is quicker and requires less skill to achieve the required suturing quality. The design of the fixators is described in terms of the thermal shape recovery of shape memory alloy and a novel form of finite element analysis, which uses a nonlinear elastic element for the material property. Thermal analysis of the fixators and surrounding tissue is used to predict the temperature distribution during and after the application of electric current heating. This was checked in an in vitro experiment, which confirmed that deployment caused no detectable collateral damage to surrounding tissue. In vivo animal studies on the use of the shape memory alloy fixator for suturing tissue are ongoing to establish safety and healing effects.

  15. Clinical audit in gynecological cancer surgery: development of a risk scoring system to predict adverse events.

    Science.gov (United States)

    Kondalsamy-Chennakesavan, Srinivas; Bouman, Chantal; De Jong, Suzanne; Sanday, Karen; Nicklin, Jim; Land, Russell; Obermair, Andreas

    2009-12-01

    Advanced gynecological surgery undertaken in a specialized gynecologic oncology unit may be associated with significant perioperative morbidity. Validated risk prediction models are available for general surgical specialties but currently not for gynecological cancer surgery. The objective of this study was to evaluate risk factors for adverse events (AEs) of patients treated for suspected or proven gynecological cancer and to develop a clinical risk score (RS) to predict such AEs. AEs were prospectively recorded and matched with demographical, clinical and histopathological data on 369 patients who had an abdominal or laparoscopic procedure for proven or suspected gynecological cancer at a tertiary gynecological cancer center. Stepwise multiple logistic regression was used to determine the best predictors of AEs. For the risk score (RS), the coefficients from the model were scaled using a factor of 2 and rounded to the nearest integer to derive the risk points. Sum of all the risk points form the RS. Ninety-five patients (25.8%) had at least one AE. Twenty-nine (7.9%) and 77 (20.9%) patients experienced intra- and postoperative AEs respectively with 11 patients (3.0%) experiencing both. The independent predictors for any AE were complexity of the surgical procedure, elevated SGOT (serum glutamic oxaloacetic transaminase, > or /=35 U/L), higher ASA scores and overweight. The risk score can vary from 0 to 14. The risk for developing any AE is described by the formula 100 / (1 + e((3.697 - (RS /2)))). RS allows for quantification of the risk for AEs. Risk factors are generally not modifiable with the possible exception of obesity.

  16. Time-motion analysis of clinical nursing documentation during implementation of an electronic operating room management system for ophthalmic surgery.

    Science.gov (United States)

    Read-Brown, Sarah; Sanders, David S; Brown, Anna S; Yackel, Thomas R; Choi, Dongseok; Tu, Daniel C; Chiang, Michael F

    2013-01-01

    Efficiency and quality of documentation are critical in surgical settings because operating rooms are a major source of revenue, and because adverse events may have enormous consequences. Electronic health records (EHRs) have potential to impact surgical volume, quality, and documentation time. Ophthalmology is an ideal domain to examine these issues because procedures are high-throughput and demand efficient documentation. This time-motion study examines nursing documentation during implementation of an EHR operating room management system in an ophthalmology department. Key findings are: (1) EHR nursing documentation time was significantly worse during early implementation, but improved to a level near but slightly worse than paper baseline, (2) Mean documentation time varied significantly among nurses during early implementation, and (3) There was no decrease in operating room turnover time or surgical volume after implementation. These findings have important implications for ambulatory surgery departments planning EHR implementation, and for research in system design.

  17. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  18. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  19. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  20. THE N.I. PIROGOV'S CONTRIBUTION TO THE SURGERY OF MUSCULOSKELETAL SYSTEM (ON THE OCCASION OF THE 200-th ANNIVERSARY OF THE BIRTH

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2010-01-01

    Full Text Available Based on the analysis of the scientific heritage the authors presented the contribution of the great Russian surgeon N.I. Pirogov in the development of surgery of the locomotor system. Discussed in detail next lines of activity of N.I. Pirogov being of interest of trauma and orthopedic surgeons, in particular the: anatomical and physiological approach to studying the issues of surgery of extremities, development of scientific and organizational bases in the domestic military-field surgery, the Pirogov's ideas in the field of reconstructive surgery of the extremities, as well as its contribution to the reforming of surgical education in Russia and improvement of the domestic surgical instruments.

  1. Comparative Study of 2D and 3D Optical Imaging Systems: Laparoendoscopic Single-Site Surgery in an Ex Vivo Model.

    Science.gov (United States)

    Vilaça, Jaime; Pinto, José Pedro; Fernandes, Sandra; Costa, Patrício; Pinto, Jorge Correia; Leão, Pedro

    2017-12-01

    Usually laparoscopy is performed by means of a 2-dimensional (2D) image system and multiport approach. To overcome the lack of depth perception, new 3-dimensional (3D) systems are arising with the added advantage of providing stereoscopic vision. To further reduce surgery-related trauma, there are new minimally invasive surgical techniques being developed, such as LESS (laparoendoscopic single-site) surgery. The aim of this study was to compare 2D and 3D laparoscopic systems in LESS surgical procedures. All participants were selected from different levels of experience in laparoscopic surgery-10 novices, 7 intermediates, and 10 experts were included. None of the participants had had previous experience in LESS surgery. Participants were chosen randomly to begin their experience with either the 2D or 3D laparoscopic system. The exercise consisted of performing an ex vivo pork cholecystectomy through a SILS port with the assistance of a fixed distance laparoscope. Errors, time, and participants' preference were recorded. Statistical analysis of time and errors between groups was conducted with a Student's t test (using independent samples) and the Mann-Whitney test. In all 3 groups, the average time with the 2D system was significantly reduced after having used the 3D system ( P 3D system. This study suggests that the 3D system may improve the learning curve and that learning from the 3D system is transferable to the 2D environment. Additionally, the majority of participants prefer 3D equipment.

  2. Grid-enabled SEE++, A Grid-Based Medical Decision Support System for Eye Muscle Surgery Conference

    CERN Document Server

    Schreiner, W.; Buchberger, M.; Kaltofen, T.

    2006-01-01

    JKU/RISC currently develops in cooperation with Upper Austrian Research (UAR) the SEE-GRID software system. SEE-GRID is based on the SEE++ software for the biomechanical 3D simulation of the human eye and its muscles. SEE++ simulates the common eye muscle surgery techniques in a graphic interactive way that is familiar to an experienced surgeon. SEE++ is world-wide the most advanced software for this purpose; it is used by various hospitals and medical doctors for surgery training and planning, SEE++ deals with the support of diagnosis and treatment of strabismus, which is the common name given to usually persistent or regularly occuring misalignment of the eyes. Strabismus is a visual defect in which eyes point in different directions. A person suffering from it may see double images due to misaligned eyes. SEE++ is able to simulate the result of the Hess-Lancaster test, from which the pathological reason of strabismus can be estimated. The outcome of such an examination is two gaze patterns of blue points a...

  3. Increasing safety of a robotic system for inner ear surgery using probabilistic error modeling near vital anatomy

    Science.gov (United States)

    Dillon, Neal P.; Siebold, Michael A.; Mitchell, Jason E.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Webster, Robert J.

    2016-03-01

    Safe and effective planning for robotic surgery that involves cutting or ablation of tissue must consider all potential sources of error when determining how close the tool may come to vital anatomy. A pre-operative plan that does not adequately consider potential deviations from ideal system behavior may lead to patient injury. Conversely, a plan that is overly conservative may result in ineffective or incomplete performance of the task. Thus, enforcing simple, uniform-thickness safety margins around vital anatomy is insufficient in the presence of spatially varying, anisotropic error. Prior work has used registration error to determine a variable-thickness safety margin around vital structures that must be approached during mastoidectomy but ultimately preserved. In this paper, these methods are extended to incorporate image distortion and physical robot errors, including kinematic errors and deflections of the robot. These additional sources of error are discussed and stochastic models for a bone-attached robot for otologic surgery are developed. An algorithm for generating appropriate safety margins based on a desired probability of preserving the underlying anatomical structure is presented. Simulations are performed on a CT scan of a cadaver head and safety margins are calculated around several critical structures for planning of a robotic mastoidectomy.

  4. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  5. Solo surgeon single-port laparoscopic surgery with a homemade laparoscope-anchored instrument system in benign gynecologic diseases.

    Science.gov (United States)

    Yang, Yun Seok; Kim, Seung Hyun; Jin, Chan Hee; Oh, Kwoan Young; Hur, Myung Haeng; Kim, Soo Young; Yim, Hyun Soon

    2014-01-01

    The objective of this study was to present the initial operative experience of solo surgeon single-port laparoscopic surgery (SPLS) in the laparoscopic treatment of benign gynecologic diseases and to investigate its feasibility and surgical outcomes. Using a novel homemade laparoscope-anchored instrument system that consisted of a laparoscopic instrument attached to a laparoscope and a glove-wound retractor umbilical port, we performed solo surgeon SPLS in 13 patients between March 2011 and June 2012. Intraoperative complications and postoperative surgical outcomes were determined. The primary operative procedures performed were unilateral salpingo-oophorectomy (n = 5), unilateral salpingectomy (n = 2), adhesiolysis (n = 1), and laparoscopically assisted vaginal hysterectomy (n = 5). Additional surgical procedures included additional adhesiolysis (n = 4) and ovarian drilling (n = 1).The primary indications for surgery were benign ovarian tumors (n = 5), ectopic pregnancy (n = 2), pelvic adhesion (infertility) (n = 1), and benign uterine tumors (n = 5). Solo surgeon SPLS was successfully accomplished in all procedures without a laparoscopic assistant. There were no intraoperative or postoperative complications. Our laparoscope-anchored instrument system obviates the need for an additional laparoscopic assistant and enables SPLS to be performed by a solo surgeon. The findings show that with our system, solo surgeon SPLS is a feasible and safe alternative technique for the treatment of benign gynecologic diseases in properly selected patients. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  6. The Settings, Pros and Cons of the New Surgical Robot da Vinci Xi System for Transoral Robotic Surgery (TORS): A Comparison With the Popular da Vinci Si System.

    Science.gov (United States)

    Kim, Da Hee; Kim, Hwan; Kwak, Sanghyun; Baek, Kwangha; Na, Gina; Kim, Ji Hoon; Kim, Se Heon

    2016-10-01

    The da Vinci system (da Vinci Surgical System; Intuitive Surgical Inc.) has rapidly developed in several years from the S system to the Si system and now the Xi System. To investigate the surgical feasibility and to provide workflow guidance for the newly released system, we used the new da Vinci Xi system for transoral robotic surgery (TORS) on a cadaveric specimen. Bilateral supraglottic partial laryngectomy, hypopharyngectomy, lateral oropharyngectomy, and base of the tongue resection were serially performed in search of the optimal procedures with the new system. The new surgical robotic system has been upgraded in all respects. The telescope and camera were incorporated into one system, with a digital end-mounted camera. Overhead boom rotation allows multiquadrant access without axis limitation, the arms are now thinner and longer with grabbing movements for easy adjustments. The patient clearance button dramatically reduces external collisions. The new surgical robotic system has been optimized for improved anatomic access, with better-equipped appurtenances. This cadaveric study of TORS offers guidance on the best protocol for surgical workflow with the new Xi system leading to improvements in the functional results of TORS.

  7. Robotics in General Surgery

    OpenAIRE

    Wall, James; Chandra, Venita; Krummel, Thomas

    2008-01-01

    In summary, robotics has made a significant contribution to General Surgery in the past 20 years. In its infancy, surgical robotics has seen a shift from early systems that assisted the surgeon to current teleoperator systems that can enhance surgical skills. Telepresence and augmented reality surgery are being realized, while research and development into miniaturization and automation is rapidly moving forward. The future of surgical robotics is bright. Researchers are working to address th...

  8. Rapid learning curve assessment in an ex vivo training system for microincisional glaucoma surgery.

    Science.gov (United States)

    Dang, Yalong; Waxman, Susannah; Wang, Chao; Parikh, Hardik A; Bussel, Igor I; Loewen, Ralitsa T; Xia, Xiaobo; Lathrop, Kira L; Bilonick, Richard A; Loewen, Nils A

    2017-05-09

    Increasing prevalence and cost of glaucoma have increased the demand for surgeons well trained in newer, microincisional surgery. These procedures occur in a highly confined space, making them difficult to learn by observation or assistance alone as is currently done. We hypothesized that our ex vivo outflow model is sensitive enough to allow computing individual learning curves to quantify progress and refine techniques. Seven trainees performed nine trabectome-mediated ab interno trabeculectomies in pig eyes (n = 63). An expert surgeon rated the procedure using an Operating Room Score (ORS). The extent of outflow beds accessed was measured with canalograms. Data was fitted using mixed effect models. ORS reached a half-maximum on an asymptote after only 2.5 eyes. Surgical time decreased by 1.4 minutes per eye in a linear fashion. The ablation arc followed an asymptotic function with a half-maximum inflection point after 5.3 eyes. Canalograms revealed that this progress did not correlate well with improvement in outflow, suggesting instead that about 30 eyes are needed for true mastery. This inexpensive pig eye model provides a safe and effective microsurgical training model and allows objective quantification of outcomes for the first time.

  9. Design of a multifiber light delivery system for photoacoustic-guided surgery

    Science.gov (United States)

    Eddins, Blackberrie; Bell, Muyinatu A. Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1/e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  10. Comparison of three facebow/semi-adjustable articulator systems for planning orthognathic surgery.

    Science.gov (United States)

    O'Malley, A M; Milosevic, A

    2000-06-01

    Our aim was to measure the steepness of the occlusal plane produced by three different semi-adjustable articulators: the Dentatus Type ARL, Denar MkII, and the Whipmix Quickmount 8800, and to assess the influence of possible systematic errors in positioning of study casts on articulators that are used to plan orthognathic surgery. Twenty patients (10 skeletal class II, and 10 skeletal class III) who were having pre-surgical orthodontics at Liverpool University Dental Hospital were studied. The measurement of the steepness of the occlusal plane was taken as the angle between the facebow bite-fork and the horizontal arm of the articulator. This was compared with the angle of the maxillary occlusal plane to the Frankfort plane as measured on lateral cephalometry (the gold standard). The Whipmix was closest to the gold standard as it flattened the occlusal plane by only 2 degrees (P<0.05). The results of the Denar and Dentatus differed significantly from those of the cephalogram as they flattened the occlusal plane by 5 degrees and 6. 5 degrees (P<0.01), respectively. Clinicians are encouraged to verify the steepness of the occlusal plane on mounted study casts before the technician makes the model. Copyright 2000 The British Association of Oral and Maxillofacial Surgeons.

  11. [Can Topical Negative Pressure Therapy be Performed as a Cost-Effective General Surgery Procedure in the German DRG System?].

    Science.gov (United States)

    Hirche, Z; Xiong, L; Hirche, C; Willis, S

    2016-04-01

    Topical negative pressure therapy (TNPT) has been established for surgical wound therapy with different indications. Nevertheless, there is only sparse evidence regarding its therapeutic superiority or cost-effectiveness in the German DRG system (G-DRG). This study was designed to analyse the cost-effectiveness of TNPT in the G-DRG system with a focus on daily treatment costs and reimbursement in a general surgery care setting. In this retrospective study, we included 176 patients, who underwent TNPT between 2007 and 2011 for general surgery indications. Analysis of the cost-effectiveness involved 149 patients who underwent a simulation to calculate the reimbursement with or without TNPT by a virtual control group in which the TNP procedure was withdrawn for DRG calculation. This was followed by a calculation of costs for wound dressings and TNPT rent and material costs. Comparison between the "true" and the virtual group enabled calculation of the effective remaining surplus per case. Total reimbursement by included TNPT cases was 2,323 ,70.04 €. Costs for wound dressings and TNPT rent were 102,669.20 €. In 41 cases there was a cost-effectiveness (27.5%) with 607,422.03 € with TNP treatment, while the control group without TNP generated revenues of 442,015.10 €. Costs for wound dressings and TNPT rent were 47,376.68 €. In the final account we could generate a cost-effectiveness of 6759 € in 5 years per 149 patients by TNPT. In 108 cases there was no cost-effectiveness (72.5%). TNPT applied in a representative general surgery setting allows for wound therapy without a major financial burden. Based on the costs for wound dressings and TNPT rent, a primarily medically based decision when to use TNPT can be performed in a balanced product cost accounting. This study does not analyse the superiority of TNPT in wound care, so further prospective studies are required which focus on therapeutic superiority and cost-effectiveness. Georg Thieme

  12. [Gases in vitreoretinal surgery].

    Science.gov (United States)

    Janco, L; Vida, R; Bartos, M; Villémová, K; Izák, M

    2012-02-01

    To evaluate the importance and benefits of using gases in vitreoretinal surgery. The gases represent a wide group of substances used in eye surgery for more than 100 years. The role of intraocular gases in vitreoretinal surgery is irreplaceable. Their use is still considered to be the "gold standard". An important step in eye surgery was the introduction of expanding gases--sulfur hexafluoride and perfluorocarbons into routine clinical practice. The most common indications for the use of intraocular gases are: retinal detachment, idiopathic macular hole, complications of vitreoretinal surgery and others. The introduction of intraocular gases into routine clinical practice, along with other modern surgical techniques resulted in significant improvement of postoperative outcomes in a wide range of eye diseases. Understanding the principles of intraocular gases use brings the benefits to the patient and physician as well. Due to their physical and chemical properties they pose far the best and most appropriate variant of intraocular tamponade. Gases also bring some disadvantages, such as difficulties in detailed fundus examination, visual acuity testing, ultrasonographic examination, difficulties in application of intravitreal drugs or reduced possibility of retina laser treatment. The gases significantly change optical system properties of the eye. The use of gases in vitreoretinal surgery has significantly increased success rate of retinal detachment surgery, complicated posterior segment cases, trauma, surgery of the macula and other diseases.

  13. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  14. The Effect of Systemic and Regional Use of Magnesium Sulfate on Postoperative Tramadol Consumption in Lumbar Disc Surgery

    Directory of Open Access Journals (Sweden)

    Melek Demiroglu

    2016-01-01

    Full Text Available Aim. To investigate the effect of magnesium administered to the operative region muscle and administered systemically on postoperative analgesia consumption after lumbar disc surgery. Material and Method. The study included a total of 75 ASA I-II patients aged 18–65 years. The patients were randomly allocated into 1 of 3 groups of 25: the Intravenous (IV Group, the Intramuscular (IM Group, and the Control (C Group. At the stage of suturing the surgical incision site, the IV Group received 50 mg/kg MgSO4 intravenously in 150 mL saline within 30 mins. In the IM Group, 50 mg/kg MgSO4 in 30 mL saline was injected intramuscularly into the paraspinal muscles. In Group C, 30 mL saline was injected intramuscularly into the paraspinal muscles. After operation patients in all 3 groups were given 100 mg tramadol and 10 mg metoclopramide and tramadol solution was started intravenously through a patient-controlled analgesia device. Hemodynamic changes, demographic data, duration of anesthesia and surgery, pain scores (NRS, the Ramsay sedation score (RSS, the amount of analgesia consumed, nausea- vomiting, and potential side effects were recorded. Results. No difference was observed between the groups. Nausea and vomiting side effects occurred at a rate of 36% in Group C, which was a significantly higher rate compared to the other groups (p<0.05. Tramadol consumption in the IM Group was found to be significantly lower than in the other groups (p<0.05. Conclusion. Magnesium applied to the operative region was found to be more effective on postoperative analgesia than systemically administered magnesium.

  15. Intraoperative direct electrical stimulations of central nervous system during surgery of gliomas near eloquent areas

    Directory of Open Access Journals (Sweden)

    WANG Wei-min

    2012-12-01

    Full Text Available Objective To report our experiences of direct cortical stimulation in surgery of gliomas located in eloquent areas. Methods Clinical data of 157 patients with gliomas underwent awake craniotomy with the direct electrical stimulation for functional mapping of the eloquent areas were analysed retrospectively. Results Negative cortical stimulation was found in 4 patients, and positive cortical stimulation was achieved in 153 patients (97.45% . Four hundred and ninty -six cortical sites in 139 patients were detected for motor response by direct electrical stimulation, 70 sites in 21 patients for sensory, 112 sites in 91 patients for language (such as counting and naming. The positive areas of counting disturbance were mainly seen at the lower part of left precentral gyri operculum of left inferior frontal gyri, triangular part of left inferior frontal gyri, posterior part of left middle frontal gyri, and posterior part of left superior frontal gyri. Postoperative MRI showed 92 patients (58.60% achieved total resection, 55 cases (35.03% subtotal and 10 cases (6.37% partial. One hundred and ten patients (70.06% were diagnosed as having low grade glimas, including 71 cases of astrocytoma, 26 cases of oligodendroglioma, and 13 cases of mixed astro ? oligodendroglioma, 47 patients (29.94% were high grade gliomas, including 19 cases of glioblastoma, 15 cases of anaplastic astrocytoma, and 13 cases of anaplastic oligodendroglioma. After operation 53 patients (33.76% occurred transient postoperative paralysis, 39 patients (24.84% transient language disturbance and 4 patients (2.55% permanent neurological deficits. Conclusion Intraoperative direct electrical stimulation is a reliable, precise and safety method for functional mapping of the eloquent areas. This technique allows us to achieve 'maximal safety resection' in glioma surgery.

  16. Does prophylactic administration of systemic antibiotics prevent postoperative inflammatory complications after third molar surgery?

    Science.gov (United States)

    Halpern, Leslie R; Dodson, Thomas B

    2007-02-01

    To estimate and compare the frequencies of inflammatory complications after third molar (M3) surgery in subjects receiving intravenous prophylactic antibiotics or saline placebo. Using a placebo-controlled, double-blind, randomized clinical trial, the investigators enrolled a sample composed of subjects who required extraction of at least 1 impacted M3 and requested intravenous sedation or general anesthesia. The predictor variable was treatment group classified as active treatment (penicillin or clindamycin for penicillin-allergic subjects) or placebo (0.9% saline). Study medications were randomly assigned. Both surgeon and subject were blinded to treatment assignment. The medication was administered intravenously prior to any incision. The outcome variable was postoperative inflammatory complication classified as present or absent and included alveolar osteitis (AO) or surgical site infection (SSI). Other variables were demographic, anatomic, or operative. Descriptive and bivariate statistics were computed. Statistical significance was set at P < or = .05, single-tailed test of hypothesis. The sample was composed of 118 subjects (n = 59 per study group). In the active treatment group, there were no postoperative inflammatory complications. In the placebo group, 5 subjects (8.5%) were diagnosed with SSI, (P = .03). No subject met the case definition for AO. All SSIs were associated with the removal of partial bony or full bony impacted mandibular M3s. In the setting of third molar removal, these results suggest that the use of intravenous antibiotics administered prophylactically decrease the frequency of SSIs. The authors cannot comment on the efficacy of intravenous antibiotics in comparison to other antibacterial treatment regimens, eg chlorhexidine mouthrinse or intrasocket antibiotics.

  17. A Cost-Effective, In-House, Positioning and Cutting Guide System for Orthognathic Surgery.

    Science.gov (United States)

    McAllister, Peter; Watson, Melanie; Burke, Ezra

    2018-03-01

    Technological advances in 3D printing can dramatically improve orthognathic surgical planning workflow. Custom positioning and cutting guides enable intraoperative reproduction of pre-planned osteotomy cuts and can result in greater surgical accuracy and patient safety. This short paper describes the use of freeware (some with open-source) combined with in-house 3D printing facilities to produce reliable, affordable osteotomy cutting guides. Open-source software (3D Slicer) is used to visualise and segment three-dimensional planning models from imported conventional computed tomography (CT) scans. Freeware (Autodesk Meshmixer ©) allows digital manipulation of maxillary and mandibular components to plan precise osteotomy cuts. Bespoke cutting guides allow exact intraoperative positioning. These are printed in polylactic acid (PLA) using a fused-filament fabrication 3D printer. Fixation of the osteotomised segments is achieved using plating templates and four pre-adapted plates with planned screw holes over the thickest bone. We print maxilla/ mandible models with desired movements incorporated to use as a plating template. A 3D printer capable of reproducing a complete skull can be procured for £1000, with material costs in the region of £10 per case. Our production of models and guides typically takes less than 24 hours of total print time. The entire production process is frequently less than three days. Externally sourced models and guides cost significantly more, frequently encountering costs totalling £1500-£2000 for models and guides for a bimaxillary osteotomy. Three-dimensional guided surgical planning utilising custom cutting guides enables the surgeon to determine optimal orientation of osteotomy cuts and better predict the skeletal maxilla/mandible relationship following surgery. The learning curve to develop proficiency using planning software and printer settings is offset by increased surgical predictability and reduced theatre time, making this

  18. Real-time 3-dimensional virtual reality navigation system with open MRI for breast-conserving surgery

    International Nuclear Information System (INIS)

    Tomikawa, Morimasa; Konishi, Kozo; Ieiri, Satoshi; Hong, Jaesung; Uemura, Munenori; Hashizume, Makoto; Shiotani, Satoko; Tokunaga, Eriko; Maehara, Yoshihiko

    2011-01-01

    We report here the early experiences using a real-time three-dimensional (3D) virtual reality navigation system with open magnetic resonance imaging (MRI) for breast-conserving surgery (BCS). Two patients with a non-palpable MRI-detected breast tumor underwent BCS under the guidance of the navigation system. An initial MRI for the breast tumor using skin-affixed markers was performed immediately prior to excision. A percutaneous intramammary dye marker was applied to delineate an excision line, and the computer software '3D Slicer' generated a real-time 3D virtual reality model of the tumor and the puncture needle in the breast. Under guidance by the navigation system, marking procedures were performed without any difficulties. Fiducial registration errors were 3.00 mm for patient no.1, and 4.07 mm for patient no.2. The real-time 3D virtual reality navigation system with open MRI is feasible for safe and accurate excision of non-palpable MRI-detected breast tumors. (author)

  19. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ...

  20. Ranking sources of hospital quality information for orthopedic surgery patients: consequences for the system of managed competition.

    Science.gov (United States)

    Bes, Romy Evelien; van den Berg, Bernard

    2013-01-01

    Healthcare quality information is crucial for the system of managed competition. Within a system of managed competition, health insurers can selectively contract care providers and are allowed to channel patients towards contracted providers. The idea is that insurers have a stronger bargaining position compared to care providers when they are able to channel patients. In the Dutch system of managed competition that was implemented in 2006, channelling patients to preferred providers has not yet been very successful. Empirical knowledge of which sources of hospital quality information they find important may help us to understand how to channel patients to preferred providers. The objective of this survey was to measure how patients rank various sources of information when they compare hospital quality in a system of managed competition. A written survey was conducted among clients of a large Dutch health insurance company. These clients underwent orthopedic surgery on the hip or knee no longer than 12 months ago. Two major players within a system of managed competition-health insurers and the government-were not seen as important sources of hospital quality information. In contrast, own experience and general practitioners (GPs) were seen as the most important sources of hospital quality information within the Dutch system of managed competition. Health insurers should take the main finding-that GPs are the most important source of hospital quality information-into account when they contract care providers and develop strategies for channeling patients towards preferred providers. A well-functioning system of managed competition will benefit patients, as it involves incentives for care providers to increase healthcare quality and to produce at the lowest cost per unit of quality.

  1. Surgical outcomes of robot-assisted rectal cancer surgery using the da Vinci Surgical System: a multi-center pilot Phase II study.

    Science.gov (United States)

    Tsukamoto, Shunsuke; Nishizawa, Yuji; Ochiai, Hiroki; Tsukada, Yuichiro; Sasaki, Takeshi; Shida, Dai; Ito, Masaaki; Kanemitsu, Yukihide

    2017-12-01

    We conducted a multi-center pilot Phase II study to examine the safety of robotic rectal cancer surgery performed using the da Vinci Surgical System during the introduction period of robotic rectal surgery at two institutes based on surgical outcomes. This study was conducted with a prospective, multi-center, single-arm, open-label design to assess the safety and feasibility of robotic surgery for rectal cancer (da Vinci Surgical System). The primary endpoint was the rate of adverse events during and after robotic surgery. The secondary endpoint was the completion rate of robotic surgery. Between April 2014 and July 2016, 50 patients were enrolled in this study. Of these, 10 (20%) had rectosigmoid cancer, 17 (34%) had upper rectal cancer, and 23 (46%) had lower rectal cancer; six underwent high anterior resection, 32 underwent low anterior resection, 11 underwent intersphincteric resection, and one underwent abdominoperineal resection. Pathological stages were Stage 0 in 1 patient, Stage I in 28 patients, Stage II in 7 patients and Stage III in 14 patients. Pathologically complete resection was achieved in all patients. There was no intraoperative organ damage or postoperative mortality. Eight (16%) patients developed complications of all grades, of which 2 (4%) were Grade 3 or higher, including anastomotic leakage (2%) and conversion to open surgery (2%). The present study demonstrates the feasibility and safety of robotic rectal cancer surgery, as reflected by low morbidity and low conversion rates, during the introduction period. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. GENERAL SURGERY

    African Journals Online (AJOL)

    in the endoscopy room. GENERAL SURGERY. T du Toit, O C Buchel, S J A Smit. Department of Surgery, University of the Free State, Bloemfontein, ... The lack of video instrumentation in developing countries: Redundant fibre-optic instruments (the old. “eye scope”) are still being used. This instrument brings endoscopists ...

  3. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  4. Choosing surgery

    DEFF Research Database (Denmark)

    Thorstensson, Carina; Lohmander, L; Frobell, Richard

    2009-01-01

    -depth qualitative interviews were conducted with young (aged 18-35), physically active individuals with ACL rupture who were participating in a RCT comparing training and surgical reconstruction with training only. 22/34 were randomised to training only but crossed over to surgery. Of these, 11 were interviewed......ABSTRACT: BACKGROUND: The objective was to understand patients' views of treatment after acute anterior cruciate ligament (ACL) injury, and their reasons for deciding to request surgery despite consenting to participate in a randomised controlled trial (to 'cross-over'). METHODS: Thirty-four in...... before surgery, and 11 were interviewed at least 6 months after surgery. To provide additional information, 12 patients were interviewed before randomisation. Interviews were audio-recorded, transcribed and analysed using the Framework approach. RESULTS: Strong preference for surgery was commonplace...

  5. Reconstructive surgery for male stress urinary incontinence: Experiences using the ATOMS system at a single center

    Directory of Open Access Journals (Sweden)

    Krause, Jens

    2014-12-01

    Full Text Available Objective: To propose possible success-driven solutions for problem and complication rates encountered with the ATOMS sling system, based on first-hand experience; and to provide possible actual alternative scenarios for the treatment of male . Patients and methods: During the defined period (between 4/2010 and 04/2014, 36 patients received ATOMS system implants at our clinic. We collected pre- and post-operative evaluation data using the International Consultation on Incontinence Questionnaire Short Form (ICIQ SF. As an expansion of the questionnaire, we added questions about post-operative perineal pain, the general satisfaction with the results of the intervention and willingness to recommend the operation to a best friend. Results: Our data shows a relatively high explantation rate, but a surprisingly high patient satisfaction rate. Explantation was required mainly due to late onset infections or other symptomatic factors. Compared to other studies early onset infections were rare. Conclusion: A non-invasive, uncomplicated adjustable system to alleviate male stress urinary incontinence remains a challenge. Although there are various systems available for the treatment of male stress urinary incontinence, it seems that despite the advantages of the ATOMS system, an artificial sphincter system may pose more advantages based on our experience, understanding and knowledge of its well-documented long-term solutions and problems.

  6. Innovations in robotic surgery.

    Science.gov (United States)

    Gettman, Matthew; Rivera, Marcelino

    2016-05-01

    Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.

  7. IMU-based Real-time Pose Measurement system for Anterior Pelvic Plane in Total Hip Replacement Surgeries.

    Science.gov (United States)

    Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen

    2017-07-01

    With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.

  8. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  9. Outpatient follow-up system using a personal computer for patients with hepatocellular carcinoma after surgery.

    Science.gov (United States)

    Itasaka, H; Matsumata, T; Taketomi, A; Yamamoto, K; Yanaga, K; Takenaka, K; Akazawa, K; Sugimachi, K

    1994-12-01

    A simple outpatient follow-up system was developed with a laptop personal computer to assist management of patients with hepatocellular carcinoma after hepatic resections. Since it is based on a non-relational database program and the graphical user interface of Macintosh operating system, those who are not a specialist of the computer operation can use it. It is helpful to promptly recognize current status and problems of the patients, to diagnose recurrences of the disease and to prevent lost from follow-up cases. A portability of the computer also facilitates utilization of these data everywhere, such as in clinical conferences and laboratories.

  10. Lapabot: a compact telesurgical robot system for minimally invasive surgery: part II. Telesurgery evaluation.

    Science.gov (United States)

    Park, Jun Woo; Lee, Duck Hee; Kim, Young Woo; Lee, Byeong Han; Jo, Yung Ho

    2012-05-01

    As described in Part I, the Lapabot was developed considering telesurgery from the initial design stage. The robot configuration is based on the master-slave structure in which the operator can be separated spatially from the patient. The distributed control architecture communicating through high-speed network enables remote control of surgical robot manipulators. In this work, we added network communication modules using user datagram protocol/internet protocol for implementation of the telesurgical system. For a stable network environment, a dedicated research network was adopted. To characterize the network environment, a data packet sender and a repeater whose packet length and packet structure are similar to those of the real data packet were developed. The developed system was evaluated through in-vitro and in-vivo experiments. With the developed system, we have successfully performed remote control of the Lapabot. The roundtrip time delay for the control signal ranged from 1.4 to 4.1 ms. The total time delay for the operator including image signal acquisition and transmission delays was under 333 ms. It did not impede surgical procedures. Initial evaluation results demonstrate the feasibility of the developed telesurgical system.

  11. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery

    NARCIS (Netherlands)

    Webers, V.S.C.; Bauer, N.J.C.; Visser, N.; Berendschot, T.T.J.M.; van den Biggelaar, F.J.H.M.; Nuijts, R.M.M.A.

    2017-01-01

    Purpose To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. Setting University Eye Clinic Maastricht, Maastricht, the Netherlands. Design Prospective randomized clinical trial. Methods Eyes with

  12. Improving breast cancer outcome by preoperative systemic therapy and image-guided surgery

    NARCIS (Netherlands)

    Mieog, Jan Sven David

    2011-01-01

    This thesis consists of two parts. In part I, we have demonstrated that preoperatively administrated systemic (neoadjuvant) therapy is a feasible treatment strategy in early stage breast cancer to achieve improved surgical options and to assess tumor response. We also demonstrated that

  13. Ex vivo evaluation of super pulse diode laser system with smart temperature feedback for contact soft-tissue surgery

    Science.gov (United States)

    Yaroslavsky, Ilya; Boutoussov, Dmitri; Vybornov, Alexander; Perchuk, Igor; Meleshkevich, Val; Altshuler, Gregory

    2018-02-01

    Until recently, Laser Diodes (LD) have been limited in their ability to deliver high peak power levels, which, in turn, limited their clinical capabilities. New technological developments made possible advent of "super pulse" LD (SPLD). Moreover, advanced means of smart thermal feedback enable precise control of laser power, thus ensuring safe and optimally efficacious application. In this work, we have evaluated a prototype SPLD system ex vivo. The device provided up to 25 W average and up to 150 W pulse power at 940 nm wavelength. The laser was operated in the thermal feedback-controlled mode, where power of the laser was varied automatically as a function of real-time thermal feedback to maintain constant tip temperature. The system was also equipped with a fiber tip initiated with advanced TiO2 /tungsten technique. Evaluation methods were designed to assess: 1) Speed and depth of cutting; 2) Dimensions of coagulative margin. The SPLD system was compared with industry-leading conventional diode and CO2 devices. The results indicate that the SPLD system provides increase in speed of controlled cutting by a factor of >2 in comparison with the conventional diode laser and approaching that of CO2 device. The produced ratio of the depth of cut to the thermal damage margin was significantly higher than conventional diodes and close to that of the CO2 system, suggesting optimal hemostasis conditions. SPLD technology with real-time temperature control has a potential for creating a new standard of care in the field of precision soft tissue surgery.

  14. Predictive ability of the Society for Vascular Surgery Wound, Ischemia, and foot Infection (WIfI) classification system following infrapopliteal endovascular interventions for critical limb ischemia

    NARCIS (Netherlands)

    J. Darling (Jeremy); J.C. McCallum (John C.); P.A. Soden (Peter A.); Meng, Y. (Yifan); Wyers, M.C. (Mark C.); Hamdan, A.D. (Allen D.); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2016-01-01

    textabstractObjective The Society for Vascular Surgery (SVS) Lower Extremity Guidelines Committee has composed a new threatened lower extremity classification system that reflects the three major factors that impact amputation risk and clinical management: Wound, Ischemia, and foot Infection (WIfI).

  15. Predictive ability of the Society for Vascular Surgery Wound, Ischemia, and foot Infection (WIfI) classification system after first-time lower extremity revascularizations

    NARCIS (Netherlands)

    J. Darling (Jeremy); J.C. McCallum (John C.); P.A. Soden (Peter A.); Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Hamdan, A.D. (Allen D.); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2017-01-01

    markdownabstract__Objective:__ The Society for Vascular Surgery (SVS) Wound, Ischemia and foot Infection (WIfI) classification system was proposed to predict 1-year amputation risk and potential benefit from revascularization. Our goal was to evaluate the predictive ability of this scale in a

  16. Impact of a national system for waitlist prioritization: the experience with NIKE and cataract surgery in Sweden.

    Science.gov (United States)

    Ng, Jonathon Q; Lundström, Mats

    2014-06-01

      To evaluate waiting times for first-eye cataract surgery in Sweden following widespread adoption of the Nationell Indikationsmodell for Kataraktextraktion (NIKE) tool for prioritizing patients for cataract surgery.   Waiting times for all first-eye cataract surgeries in Sweden in 2009-2011 were identified from the Swedish National Cataract Register. Waiting times were compared according to demographic, clinical and NIKE indication group for surgery. Multivariate logistic regression modelling was used to determine factors associated with waiting times less than the 3-month Government guarantee period.   There were 141,070 first-eye cataract surgeries in 2009 to 2011; an annual increase of around 6%. Over the study period, mean waiting times decreased across all NIKE groups. The proportion waiting NIKE groups. Surgery within 3 months of waitlisting was more likely for patients with a NIKE 1 indication classification (most need for surgery), in later years, male patients, younger patients and patients with a preoperative visual acuity in the better eye worse than 6/24.   Prioritizing patients for cataract surgery using NIKE reduces waiting times for those with the greatest need. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. [Introduction of computerized anesthesia-recording systems and construction of comprehensive medical information network for patients undergoing surgery in the University of Tokyo Hospital].

    Science.gov (United States)

    Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu

    2009-10-01

    The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.

  18. Voltage controlled nano-injection system for single-cell surgery

    Science.gov (United States)

    Seger, R. Adam; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2015-01-01

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes. PMID:22899383

  19. Coronary Artery Bypass Graft Surgery Cost Coverage by the Brazilian Unified Health System (SUS

    Directory of Open Access Journals (Sweden)

    Gilmara Silveira da Silva

    Full Text Available Abstract Introduction: Cost management has been identified as an essential tool for the general control and evaluation of health organizations. Objectives: To identify the coverage percentage of transferred funds from the Unified Health System for coronary artery bypass grafts in a philanthropic hospital having a consolidated costing system in the municipality of São Paulo. Methods: A quantitative, descriptive and cross-sectional research with information provided from a database composed of 1913 patients undergoing coronary artery bypass graft from March 13 to September 30, 2012, including isolated elective coronary artery bypass graft with the use of extracorporeal circulation. It excluded 551 (28.8% patients, among them 76 (4.0% deaths and 8 hospitalized patients, since the cost was compared according to the length of hospital stay. Therefore, the sample consisted of 1362 patients. Results: The average total cost per patient was $7,992.55. The average fund transfer by the Unified Health System was $3,450.73 (48.66%, resulting in a deficit of $4,541.82 (51.34%. Conclusion: The Unified Health System transfers covered 48.66% of the average total cost of hospitalization. Although the amount transferred increased with increasing costs, it was not proportional to the total cost, resulting in a percentage difference in revenue that was increasingly negative for each increase in cost and hospital stay. Those hospitalized for longer than seven days presented higher costs, older age, higher percentage of diabetics and chronic kidney disease patients and more postoperative complications.

  20. The Role of the Distal Runoff Vessel of the Descending Branch of the Lateral Circumflex Femoral System in Anterolateral Thigh Flap Surgery: A Case Series and Literature Review.

    Science.gov (United States)

    He, Xiao-Qing; Zhu, Yue-Liang; Wang, Yi; Mei, Liang-Bin; Jin, Tao; Xu, Yong-Qing

    2016-01-01

    As a distal portion of the descending branch of the lateral circumflex femoral system (LCFS), the role of the distal runoff vessel in anterolateral thigh (ALT) flap surgery has long been overlooked. Recently, however, the distal runoff vessel has been increasingly used in many aspects of ALT flap surgery, and it has exhibited superior properties in solving some difficult problems. Fourteen ALT flaps using the distal runoff vessel of the descending branch of the LCFS for extremity defects were retrospectively reviewed, and recent reports on using the distal runoff vessel were reviewed to determine the role of this vessel in ALT flap surgery. In our series, the distal runoff vessel was used as a flow-through pattern in 10 cases, as a recombined chimeric flap in 2 cases, and as a backup vessel for flap salvage in 2 cases. All of the ALT flaps completely survived. None of the donor sites presented with additional morbidity as a result of harvesting the distal runoff vessel. In the literature review, the following are 5 other options for using the distal runoff vessel: in interposition artery and vein grafts, as the pedicle of the reverse-flow ALT flap, as the recipient vessel, to avoid twisting, and as a monitoring method. The distal runoff vessel of the descending branch of the LCFS could be used for many aspects of the ALT flap surgery, and this vessel plays an irreplaceable role in some difficult reconstruction surgeries.

  1. Effect of bariatric surgery-induced weight loss on renal and systemic inflammation and blood pressure: a 12-month prospective study.

    Science.gov (United States)

    Fenske, Wiebke K; Dubb, Sukhpreet; Bueter, Marco; Seyfried, Florian; Patel, Karishma; Tam, Frederick W K; Frankel, Andrew H; le Roux, Carel W

    2013-01-01

    Bariatric surgery improves arterial hypertension and renal function; however, the underlying mechanisms and effect of different surgical procedures are unknown. In the present prospective study, we compared the 12-month follow-up results after Roux-en-Y gastric bypass, laparoscopic adjustable gastric banding, and laparoscopic sleeve gastrectomy on weight loss, hypertension, renal function, and inflammatory status. A total of 34 morbidly obese patients were investigated before, one and 12 months after Roux-en-Y gastric bypass (n = 10), laparoscopic adjustable gastric banding (n = 13), and laparoscopic sleeve gastrectomy (n = 11) for hypertension, kidney function, urinary and serum cytokine levels of macrophage migration inhibitory factor, monocyte chemotactic protein-1, and chemokine ligand-18. At 12 months after surgery, the patients in all 3 treatment arms showed a significant decrease in the mean body mass index, mean arterial pressure, and urinary and serum inflammatory markers (all P .8 mg/L) had a marked improvement in renal function 12 months after surgery (P < .05). Surgically induced weight loss is associated with a marked decrease in renal and systemic inflammation and arterial hypertension and improvement in renal function in patients with pre-existing renal impairment. These effects appear to be independent of surgical procedure. The improvement in renal inflammation could be 1 of the mechanisms contributing to the beneficial effects of bariatric surgery on arterial blood pressure, proteinuria, and renal function. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  2. [Evaluation of selected parameters of blood coagulation and fibrinolysis system in patients undergoing total hip replacement surgery with normovolemic hemodilution procedure and standard enoxaparine prophylaxis].

    Science.gov (United States)

    Piecuch, Wiesław; Sokołowska, Bozena; Dmoszyńska, Anna; Furmanik, Franciszek

    2003-01-01

    The aim of the study was to evaluate selected blood coagulation and fibrinolysis parameters in patients undergoing total hip replacement surgery with normovolemic hemodilution and standard enoksaparine profilaxis. The study included 66 patients undergoing hip replacement surgery. The group consisted of 51 women and 15 men, within the age range of 47-78, the mean age was 64. In 32 (subgroup II) patients the surgery was performed with the use of normovolemic hemodilution, in 34 (subgroup I) the hemodilution procedure was not applied. The enoksaparine as prophylaxis started 12 hours prior to surgery and continued during hospitalisation. The examination of the coagulation system was performed: on the day of the operation in the morning, on the day of the operation in the evening and on the first day after operation. We determined the concentrations of TAT and PAP complexes, prothrombin fragments 1 + 2 (F1 + 2) and d-dimers (DD). 1) during total hip replacement surgery and particularly in the period of the first 12 hours after the procedure marked activation of coagulation and fibrinolysis occurRed; 2) the application of the hemodilution procedure does not influence significantly the degree of coagulation and fibrinolysis disorders in the perioperative period, but could reduced incidence of thromboembolic complications in the postoperative period.

  3. An Innovative Streaming Video System With a Point-of-View Head Camera Transmission of Surgeries to Smartphones and Tablets: An Educational Utility.

    Science.gov (United States)

    Chaves, Rafael Oliveira; de Oliveira, Pedro Armando Valente; Rocha, Luciano Chaves; David, Joacy Pedro Franco; Ferreira, Sanmari Costa; Santos, Alex de Assis Santos Dos; Melo, Rômulo Müller Dos Santos; Yasojima, Edson Yuzur; Brito, Marcus Vinicius Henriques

    2017-10-01

    In order to engage medical students and residents from public health centers to utilize the telemedicine features of surgery on their own smartphones and tablets as an educational tool, an innovative streaming system was developed with the purpose of streaming live footage from open surgeries to smartphones and tablets, allowing the visualization of the surgical field from the surgeon's perspective. The current study aims to describe the results of an evaluation on level 1 of Kirkpatrick's Model for Evaluation of the streaming system usage during gynecological surgeries, based on the perception of medical students and gynecology residents. Consisted of a live video streaming (from the surgeon's point of view) of gynecological surgeries for smartphones and tablets, one for each volunteer. The volunteers were able to connect to the local wireless network, created by the streaming system, through an access password and watch the video transmission on a web browser on their smartphones. Then, they answered a Likert-type questionnaire containing 14 items about the educational applicability of the streaming system, as well as comparing it to watching an in loco procedure. This study is formally approved by the local ethics commission (Certificate No. 53175915.7.0000.5171/2016). Twenty-one volunteers participated, totalizing 294 items answered, in which 94.2% were in agreement with the items affirmative, 4.1% were neutral, and only 1.7% answers corresponded to negative impressions. Cronbach's α was .82, which represents a good reliability level. Spearman's coefficients were highly significant in 4 comparisons and moderately significant in the other 20 comparisons. This study presents a local streaming video system of live surgeries to smartphones and tablets and shows its educational utility, low cost, and simple usage, which offers convenience and satisfactory image resolution, thus being potentially applicable in surgical teaching.

  4. The effect of three different doses of tranexamic acid on blood loss after cardiac surgery with mild systemic hypothermia (32 degrees C).

    Science.gov (United States)

    Karski, J M; Dowd, N P; Joiner, R; Carroll, J; Peniston, C; Bailey, K; Glynn, M F; Teasdale, S J; Cheng, D C

    1998-12-01

    Prophylactic administration of tranexamic acid (TA), an antifibrinolytic agent, decreases bleeding after cardiac surgery with systemic hypothermia (25 degrees C to 29 degrees C). Warmer systemic temperatures during cardiopulmonary bypass (CPB) may reduce bleeding and thus alter the requirement for TA. The effect of three different doses of TA on bleeding after cardiac surgery with mild systemic hypothermia (32 degrees C) is evaluated. Double-blind, prospective, randomized study. University hospital. One hundred fifty adult patients undergoing aortocoronary bypass or valvular cardiac surgery. Patients received TA, 50 (n = 50), 100 (n = 50), or 150 (n = 50) mg/kg intravenously before CPB with mild systemic hypothermia. Blood loss through chest drains over 6, 12, and 24 hours after surgery and total hemoglobin loss were measured. Autotransfused blood, transfused banked blood and blood products, and coagulation profiles were measured. Analysis of variance on log-transformed data for blood loss and confidence intervals (CIs) of 0.95 were calculated and transformed to milliliters of blood. No patient was re-explored for bleeding. Blood loss at 6 hours was statistically greater in the 50-mg/kg group compared with the other two groups (p = 0.03; p = 0.02). Total hemoglobin loss was statistically greater in the 50-mg/kg group compared with the 150-mg/kg group (p = 0.04). There was no statistical difference in blood tranfusion rate or coagulation profiles among the three groups. However, preoperative hemoglobin level was statistically lower in the 150-mg/kg group compared with the other two groups (p = 0.01). Of the three doses of TA studied, the most efficacious and cost-effective dose to reduce bleeding after cardiac surgery with mild hypothermic systemic perfusion is 100 mg/kg.

  5. Distinguishing infected from noninfected abdominal fluid collections after surgery: an imaging, clinical, and laboratory-based scoring system.

    Science.gov (United States)

    Gnannt, Ralph; Fischer, Michael A; Baechler, Thomas; Clavien, Pierre-Alain; Karlo, Christoph; Seifert, Burkhardt; Lesurtel, Mickael; Alkadhi, Hatem

    2015-01-01

    Mortality from abdominal abscesses ranges from 30% in treated cases up to 80% to 100% in patients with undrained or nonoperated abscesses. Various computed tomographic (CT) imaging features have been suggested to indicate infection of postoperative abdominal fluid collections; however, features are nonspecific and substantial overlap between infected and noninfected collections exists. The purpose of this study was to develop and validate a scoring system on the basis of CT imaging findings as well as laboratory and clinical parameters for distinguishing infected from noninfected abdominal fluid collections after surgery. The score developmental cohort included 100 consecutive patients (69 men, 31 women; mean age, 58 ± 17 years) who underwent portal-venous phase CT within 24 hours before CT-guided intervention of postoperative abdominal fluid collections. Imaging features included attenuation (Hounsfield unit [HU]), volume, wall enhancement and thickness, fat stranding, as well as entrapped gas of fluid collections. Laboratory and clinical parameters included diabetes, intake of immunosuppressive drugs, body temperature, C-reactive protein, and leukocyte blood cell count. The score was validated in a separate cohort of 30 consecutive patients (17 men, 13 women; mean age, 51 ± 15 years) with postoperative abdominal fluid collections. Microbiologic analysis from fluid samples served as the standard of reference. Diabetes, body temperature, C-reactive protein, attenuation of the fluid collection (in HUs), wall enhancement and thickness of the wall, adjacent fat stranding, as well as entrapped gas within the fluid collection were significantly different between infected and noninfected collections (P collection (in HUs), as well as entrapped gas as significant independent predictors of infection (P collection, ≥ 20 HU: 4 points; entrapped gas: 3 points). The model was well calibrated (Hosmer-Lemeshow test, P = 0.36). In the validation cohort, scores of 2 or lower

  6. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control; Deteccao e exerese de lesoes mamarias nao palpaveis orientadas por cirurgia radioguiada com injecao de ar para controle radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Rafael Henrique Szymanski [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia]. E-mail: raffaszymanski@yahoo.com.br; Oliveira, Afranio Coelho de [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Hospital Universitario Clementino Fraga Filho; Rocha, Augusto Cesar Peixoto [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Ginecologia e Obstetricia; Souza, Sergio Augusto Lopes de; Martins, Flavia Paiva Proenca [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil); Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da [Universidade Federal (UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia]. E-mail: lmirian@globo.com

    2005-11-15

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with {sup 99m}Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  7. Cataract Surgery

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  8. Brain surgery

    Science.gov (United States)

    Craniotomy; Surgery - brain; Neurosurgery; Craniectomy; Stereotactic craniotomy; Stereotactic brain biopsy; Endoscopic craniotomy ... cut depends on where the problem in the brain is located. The surgeon creates a hole in ...

  9. Foot Surgery

    Science.gov (United States)

    ... coding trends along with compliance guidelines and practice marketing materials, APMA has you covered whether you are ... crutches after the surgery or in a cast. Fusions: Fusions are usually performed to treat arthritic or ...

  10. Hemorrhoid surgery

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002939.htm Hemorrhoid surgery To use the sharing features on this page, please enable JavaScript. Hemorrhoids are swollen veins around the anus. They may ...

  11. PLASTIC SURGERY

    African Journals Online (AJOL)

    Department of Plastic and Reconstructive Surgery Sefako Makgatho Health Science University, ... We report on a pilot study on the use of a circumareolar excision and the use of .... and 1 gynecomastia patient) requested reduction in NAC size.

  12. GENERAL SURGERY

    African Journals Online (AJOL)

    influence medical students in pursuing a career in surgery. ... training, females reported significantly higher levels of agreement that surgical training would be better overseas when ..... mentoring surgical research or educational lectures and.

  13. GENERAL SURGERY

    African Journals Online (AJOL)

    1 Department of Surgery, Nelson R Mandela School of Medicine, University of ... in 51 reports. Four reports were illegible; one was conducted by a junior consultant, two by a fourth year trainee specialist ... The study period was 12 months from.

  14. Sinus Surgery

    Science.gov (United States)

    ... sinus computed tomography (CT) scan (without contrast), nasal physiology (rhinomanometry and nasal cytology), smell testing, and selected ... altered anatomical landmarks, or where a patient’s sinus anatomy is very unusual, making typical surgery difficult. Image ...

  15. In vivo stimulus presentation to the mouse vomeronasal system: Surgery, experiment, setup, and software.

    Science.gov (United States)

    Yoles-Frenkel, Michal; Cohen, Oksana; Bansal, Rohini; Horesh, Noa; Ben-Shaul, Yoram

    2017-06-15

    Achieving controlled stimulus delivery is a major challenge in the physiological analysis of the vomeronasal system (VNS). We provide a comprehensive description of a setup allowing controlled stimulus delivery into the vomeronasal organ (VNO) of anesthetized mice. VNO suction is achieved via electrical stimulation of the sympathetic nerve trunk (SNT) using cuff electrodes, followed by flushing of the nasal cavity. Successful application of this methodology depends on several aspects including the surgical preparation, fabrication of cuff electrodes, experimental setup modifications, and the stimulus delivery and flushing. Here, we describe all these aspects in sufficient detail to allow other researchers to readily adopt it. We also present a custom written MATLAB based software with a graphical user interface that controls all aspects of the actual experiment, including trial sequencing, hardware control, and data logging. The method allows measurement of stimulus evoked sensory responses in brain regions that receive vomeronasal inputs. An experienced investigator can complete the entire surgical procedure within thirty minutes. This is the only approach that allows repeated and controlled stimulus delivery to the intact VNO, employing the natural mode of stimulus uptake. The approach is economical with respect to stimuli, requiring stimulus volumes as low as 1-2μl. This comprehensive description will allow other investigators to adapt this setup to their own experimental needs and can thus promote our physiological understanding of this fascinating chemosensory system. With minor changes it can also be adapted for other rodent species. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Effect of Roux-en-Y Bariatric Surgery on Lipoproteins, Insulin Resistance, and Systemic and Vascular Inflammation in Obesity and Diabetes

    Directory of Open Access Journals (Sweden)

    Rahul Yadav

    2017-11-01

    Full Text Available PurposeObesity is a major modifiable risk factor for cardiovascular disease. Bariatric surgery is considered to be the most effective treatment option for weight reduction in obese patients with and without type 2 diabetes (T2DM.ObjectiveTo evaluate changes in lipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction following Roux-en-Y bariatric surgery in obese patients with and without diabetes.Materials and methodsLipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction were measured in 37 obese patients with (n = 17 and without (n = 20 T2DM, before and 6 and 12 months after Roux-en-Y bariatric surgery. Two way between subject ANOVA was carried out to study the interaction between independent variables (time since surgery and presence of diabetes and all dependent variables.ResultsThere was a significant effect of time since surgery on (large effect size weight, body mass index (BMI, waist circumference, triglycerides (TG, small-dense LDL apolipoprotein B (sdLDL ApoB, HOMA-IR, CRP, MCP-1, ICAM-1, E-selectin, P-selectin, leptin, and adiponectin. BMI and waist circumference had the largest impact of time since surgery. The effect of time since surgery was noticed mostly in the first 6 months. Absence of diabetes led to a significantly greater reduction in total cholesterol, low-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol although the effect size was small to medium. There was a greater reduction in TG and HOMA-IR in patients with diabetes with a small effect size. No patients were lost to follow up.ConclusionLipoproteins, insulin resistance, mediators of systemic and vascular inflammation, and endothelial dysfunction improve mostly 6 months after bariatric surgery in obese patients with and without diabetes.Clinical Trial Registrationwww.ClinicalTrials.gov, identifier: NCT02169518. https

  17. Emergency surgery

    DEFF Research Database (Denmark)

    Stoneham, M; Murray, D; Foss, N

    2014-01-01

    National reports recommended that peri-operative care should be improved for elderly patients undergoing emergency surgery. Postoperative mortality and morbidity rates remain high, and indicate that emergency ruptured aneurysm repair, laparotomy and hip fracture fixation are high-risk procedures...... undertaken on elderly patients with limited physiological reserve. National audits have reported variations in care quality, data that are increasingly being used to drive quality improvement through professional guidance. Given that the number of elderly patients presenting for emergency surgery is likely...

  18. Robotics in Colorectal Surgery

    Science.gov (United States)

    Weaver, Allison; Steele, Scott

    2016-01-01

    Over the past few decades, robotic surgery has developed from a futuristic dream to a real, widely used technology. Today, robotic platforms are used for a range of procedures and have added a new facet to the development and implementation of minimally invasive surgeries. The potential advantages are enormous, but the current progress is impeded by high costs and limited technology. However, recent advances in haptic feedback systems and single-port surgical techniques demonstrate a clear role for robotics and are likely to improve surgical outcomes. Although robotic surgeries have become the gold standard for a number of procedures, the research in colorectal surgery is not definitive and more work needs to be done to prove its safety and efficacy to both surgeons and patients. PMID:27746895

  19. Systemic aspergilloma post aortic root surgery following coronary artery stenting: diagnostic and management dilemma

    Science.gov (United States)

    Hussein, Nabil; Qamar, Sombul; Abid, Qamar

    2015-01-01

    Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972

  20. Stereoscopic Augmented Reality System for Supervised Training on Minimal Invasive Surgery Robots

    DEFF Research Database (Denmark)

    Matu, Florin-Octavian; Thøgersen, Mikkel; Galsgaard, Bo

    2014-01-01

    the need for efficient training. When training with the robot, the communication between the trainer and the trainee is limited, since the trainee often cannot see the trainer. To overcome this issue, this paper proposes an Augmented Reality (AR) system where the trainer is controlling two virtual robotic...... arms. These arms are virtually superimposed on the video feed to the trainee, and can therefore be used to demonstrate and perform various tasks for the trainee. Furthermore, the trainer is presented with a 3D image through a stereoscopic display. Because of the added depth perception, this enables...... the procedure, and thereby enhances the training experience. The virtual overlay was also found to work as a good and illustrative approach for enhanced communication. However, the delay of the prototype made it difficult to use for actual training....

  1. Evaluation of diffusion-tensor imaging-based global search and tractography for tumor surgery close to the language system.

    Directory of Open Access Journals (Sweden)

    Mirco Richter

    Full Text Available Pre-operative planning and intra-operative guidance in neurosurgery require detailed information about the location of functional areas and their anatomo-functional connectivity. In particular, regarding the language system, post-operative deficits such as aphasia can be avoided. By combining functional magnetic resonance imaging and diffusion tensor imaging, the connectivity between functional areas can be reconstructed by tractography techniques that need to cope with limitations such as limited resolution and low anisotropic diffusion close to functional areas. Tumors pose particular challenges because of edema, displacement effects on brain tissue and infiltration of white matter. Under these conditions, standard fiber tracking methods reconstruct pathways of insufficient quality. Therefore, robust global or probabilistic approaches are required. In this study, two commonly used standard fiber tracking algorithms, streamline propagation and tensor deflection, were compared with a previously published global search, Gibbs tracking and a connection-oriented probabilistic tractography approach. All methods were applied to reconstruct neuronal pathways of the language system of patients undergoing brain tumor surgery, and control subjects. Connections between Broca and Wernicke areas via the arcuate fasciculus (AF and the inferior fronto-occipital fasciculus (IFOF were validated by a clinical expert to ensure anatomical feasibility, and compared using distance- and diffusion-based similarity metrics to evaluate their agreement on pathway locations. For both patients and controls, a strong agreement between all methods was observed regarding the location of the AF. In case of the IFOF however, standard fiber tracking and Gibbs tracking predominantly identified the inferior longitudinal fasciculus that plays a secondary role in semantic language processing. In contrast, global search resolved connections in almost every case via the IFOF which

  2. Fatal postoperative systemic pulmonary hypertension in benfluorex-induced valvular heart disease surgery: A case report.

    Science.gov (United States)

    Baufreton, Christophe; Bruneval, Patrick; Rousselet, Marie-Christine; Ennezat, Pierre-Vladimir; Fouquet, Olivier; Giraud, Raphael; Banfi, Carlo

    2017-01-01

    Drug-induced valvular heart disease (DI-VHD) remains an under-recognized entity. This report describes a heart valve replacement which was complicated by intractable systemic pulmonary arterial hypertension in a 61-year-old female with severe restrictive mitral and aortic disease. The diagnosis of valvular disease was preceded by a history of unexplained respiratory distress. The patient had been exposed to benfluorex for 6.5 years. The diagnostic procedure documented specific drug-induced valvular fibrosis. Surgical mitral and aortic valve replacement was performed. Heart valve replacement was postoperatively complicated by unanticipated disproportionate pulmonary hypertension. This issue was fatal despite intensive care including prolonged extracorporeal life support. Benfluorex is a fenfluramine derivative which has been marketed between 1976 and 2009. Although norfenfluramine is the common active and toxic metabolite of all fenfluramine derivatives, the valvular and pulmonary arterial toxicity of benfluorex was much less known than that of fenfluramine and dexfenfluramine. The vast majority of benfluorex-induced valvular heart disease remains misdiagnosed as hypothetical rheumatic fever due to similarities between both etiologies. Better recognition of DI-VHD is likely to improve patient outcome.

  3. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System.

    Science.gov (United States)

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-05-25

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction ( p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant ( p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.

  4. Smart Sensor-Based Motion Detection System for Hand Movement Training in Open Surgery.

    Science.gov (United States)

    Sun, Xinyao; Byrns, Simon; Cheng, Irene; Zheng, Bin; Basu, Anup

    2017-02-01

    We introduce a smart sensor-based motion detection technique for objective measurement and assessment of surgical dexterity among users at different experience levels. The goal is to allow trainees to evaluate their performance based on a reference model shared through communication technology, e.g., the Internet, without the physical presence of an evaluating surgeon. While in the current implementation we used a Leap Motion Controller to obtain motion data for analysis, our technique can be applied to motion data captured by other smart sensors, e.g., OptiTrack. To differentiate motions captured from different participants, measurement and assessment in our approach are achieved using two strategies: (1) low level descriptive statistical analysis, and (2) Hidden Markov Model (HMM) classification. Based on our surgical knot tying task experiment, we can conclude that finger motions generated from users with different surgical dexterity, e.g., expert and novice performers, display differences in path length, number of movements and task completion time. In order to validate the discriminatory ability of HMM for classifying different movement patterns, a non-surgical task was included in our analysis. Experimental results demonstrate that our approach had 100 % accuracy in discriminating between expert and novice performances. Our proposed motion analysis technique applied to open surgical procedures is a promising step towards the development of objective computer-assisted assessment and training systems.

  5. The Zhongshan score: a novel and simple anatomic classification system to predict perioperative outcomes of nephron-sparing surgery.

    Science.gov (United States)

    Zhou, Lin; Guo, Jianming; Wang, Hang; Wang, Guomin

    2015-02-01

    In the zero ischemia era of nephron-sparing surgery (NSS), a new anatomic classification system (ACS) is needed to adjust to these new surgical techniques. We devised a novel and simple ACS, and compared it with the RENAL and PADUA scores to predict the risk of NSS outcomes. We retrospectively evaluated 789 patients who underwent NSS with available imaging between January 2007 and July 2014. Demographic and clinical data were assessed. The Zhongshan (ZS) score consisted of three parameters. RENAL, PADUA, and ZS scores are divided into three groups, that is, high, moderate, and low scores. For operative time (OT), significant differences were seen between any two groups of ZS score and PADUA score (all P RENAL showed no significant difference between moderate and high complexity in OT, WIT, estimated blood loss, and increase in SCr. Compared with patients with a low score of ZS, those with a high or moderate score had 8.1-fold or 3.3-fold higher risk of surgical complications, respectively (all P RENAL score, patients with a high or moderate score had 5.7-fold or 1.9-fold higher risk of surgical complications, respectively (all P RENAL and PADUA scores. ZS score could be used to reflect the surgical complexity and predict the risk of surgical complications in patients undergoing NSS.

  6. Validation of Patient-Reported Outcomes Measurement Information System (PROMIS) computerized adaptive tests in cervical spine surgery.

    Science.gov (United States)

    Boody, Barrett S; Bhatt, Surabhi; Mazmudar, Aditya S; Hsu, Wellington K; Rothrock, Nan E; Patel, Alpesh A

    2018-03-01

    OBJECTIVE The Patient-Reported Outcomes Measurement Information System (PROMIS), which is funded by the National Institutes of Health, is a set of adaptive, responsive assessment tools that measures patient-reported health status. PROMIS measures have not been validated for surgical patients with cervical spine disorders. The objective of this project is to evaluate the validity (e.g., convergent validity, known-groups validity, responsiveness to change) of PROMIS computer adaptive tests (CATs) for pain behavior, pain interference, and physical function in patients undergoing cervical spine surgery. METHODS The legacy outcome measures Neck Disability Index (NDI) and SF-12 were used as comparisons with PROMIS measures. PROMIS CATs, NDI-10, and SF-12 measures were administered prospectively to 59 consecutive tertiary hospital patients who were treated surgically for degenerative cervical spine disorders. A subscore of NDI-5 was calculated from NDI-10 by eliminating the lifting, headaches, pain intensity, reading, and driving sections and multiplying the final score by 4. Assessments were administered preoperatively (baseline) and postoperatively at 6 weeks and 3 months. Patients presenting for revision surgery, tumor, infection, or trauma were excluded. Participants completed the measures in Assessment Center, an online data collection tool accessed by using a secure login and password on a tablet computer. Subgroup analysis was also performed based on a primary diagnosis of either cervical radiculopathy or cervical myelopathy. RESULTS Convergent validity for PROMIS CATs was supported with multiple statistically significant correlations with the existing legacy measures, NDI and SF-12, at baseline. Furthermore, PROMIS CATs demonstrated known-group validity and identified clinically significant improvements in all measures after surgical intervention. In the cervical radiculopathy and myelopathic cohorts, the PROMIS measures demonstrated similar responsiveness to the

  7. Tennis elbow surgery

    Science.gov (United States)

    Lateral epicondylitis - surgery; Lateral tendinosis - surgery; Lateral tennis elbow - surgery ... Surgery to repair tennis elbow is often an outpatient surgery. This means you will not stay in the hospital overnight. You will be given ...

  8. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require one or more ... find out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment ...

  9. Mohs micrographic surgery

    Science.gov (United States)

    Skin cancer - Mohs surgery; Basal cell skin cancer - Mohs surgery; Squamous cell skin cancer - Mohs surgery ... Mohs surgery usually takes place in the doctor's office. The surgery is started early in the morning and is ...

  10. Timing of surgery for hip fracture and in-hospital mortality: a retrospective population-based cohort study in the Spanish National Health System

    Directory of Open Access Journals (Sweden)

    Librero Julián

    2012-01-01

    Full Text Available Abstract Background While the benefits or otherwise of early hip fracture repair is a long-running controversy with studies showing contradictory results, this practice is being adopted as a quality indicator in several health care organizations. The aim of this study is to analyze the association between early hip fracture repair and in-hospital mortality in elderly people attending public hospitals in the Spanish National Health System and, additionally, to explore factors associated with the decision to perform early hip fracture repair. Methods A cohort of 56,500 patients of 60-years-old and over, hospitalized for hip fracture during the period 2002 to 2005 in all the public hospitals in 8 Spanish regions, were followed up using administrative databases to identify the time to surgical repair and in-hospital mortality. We used a multivariate logistic regression model to analyze the relationship between the timing of surgery ( Results Early surgery was performed on 25% of the patients. In the unadjusted analysis early surgery showed an absolute difference in risk of mortality of 0.57 (from 4.42% to 3.85%. However, patients undergoing delayed surgery were older and had higher comorbidity and severity of illness. Timeliness for surgery was not found to be related to in-hospital mortality once confounding factors such as age, sex, chronic comorbidities as well as the severity of illness were controlled for in the multivariate analysis. Conclusions Older age, male gender, higher chronic comorbidity and higher severity measured by the Risk Mortality Index were associated with higher mortality, but the time to surgery was not.

  11. Canadians leaving the Canadian health care system to seek bariatric surgery abroad: Examining patient experience with international bariatric tourism

    OpenAIRE

    Hohm, Carly Desiree

    2017-01-01

    Globally, bariatric surgery, commonly known as weight loss surgery, has grown in popularity among obese individuals as a means to addressing their weight-related negative health when more traditional weight loss programs, such as diet and exercise, fail to elicit long term sustained weight loss. In Canada, however, complex barriers related to social, administrative, and other structural factors restrict access to care domestically, leaving some patients turning to surgical options abroad thro...

  12. Minimized extracorporeal circulation system in coronary artery bypass surgery: a 10-year single-center experience with 2243 patients.

    Science.gov (United States)

    Puehler, Thomas; Haneya, Assad; Philipp, Alois; Zausig, York A; Kobuch, Reinhard; Diez, Claudius; Birnbaum, Dietrich E; Schmid, Christof

    2011-04-01

    Coronary artery bypass grafting (CABG) is the gold standard for the surgical therapy of multivessel coronary artery disease. To reduce the side effects, associated with standard extracorporeal circulation (ECC), a concept of minimal extracorporeal circulation (MECC) was devised in our center. We report on our 10-year experience with the MECC for coronary revascularization. From January 1998 to August 2009, 2243 patients underwent CABG with MECC in our center. In a retrospective observational study, we analyzed indication, preoperative patient co-morbidity, postoperative clinical course, and perioperative outcome of all patients operated on with MECC. Furthermore, the risk factors for mortality in the MECC group were assessed. Patients showed a mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) of 4.5±0.1%. The mean age of the patients was 66.8±9.1 years. The overall 30-day mortality after CABG with MECC was 2.3%, ranging from 1.1% for elective to 13.0% for emergent patients and was significantly better than standard ECC. Only 15.3% (n=344) of patients with MECC required intra-operative blood transfusion. Postoperative catecholamine support, red blood cell transfusion, need for hemodialysis, release of creatinine kinase, incidence of stroke, and postoperative delirium were low after MECC revascularization. Ejection fraction below 30% (odds ratio (OR): 5.1), emergent operation (OR: 9.4), and high-dose catecholamine therapy (OR: 2.6) were associated predictors for mortality. MECC until now is an established concept and has become an alternative for ECC in routine CABG in our center. The use of the MECC system is associated with low mortality and conversion rate. Excellent survival rates and low transfusion requirements in the perioperative course were achieved. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  13. Timing of Surgery for Spinal Fractures Associated with Systemic Trauma: A Need for a Strategic and Systemic Approach.

    Science.gov (United States)

    Koksal, Ismet; Alagoz, Fatih; Celik, Haydar; Yildirim, Ali Erdem; Akin, Tezcan; Guvenc, Yahya; Karatay, Mete; Erdem, Yavuz

    An underestimated evaluation of systemic organs in cases with spinal fractures might jeopardize the intervention for treatment and future complications with an increased morbidity and mortality are almost warranted. In the present study, a retrospective analysis of spinal fracture cases associated with systemic trauma was performed to assess surgical success. A retrospective analysis of patients with thoracolumbar fractures who were admitted to the emergency unit between September 2012 and September 2014 was used for the study. The cases were categorized according to age, sex, reason of trauma, associated trauma, neurological condition and treatment details and results were analysed using SPSS 14.0 for Windows. The most common reason of trauma is detected as falls in 101 cases (64.3%). Radiological evaluation of spinal fractures revealed a compression fracture in 106 cases (67.5%) and other fractures in 51 cases (32.5%). Surgical treatment for spinal fracture was performed in 60.5% of the cases and conservative approach was preferred in 39.5% cases. In non-compressive spinal fractures, an associated pathology like head trauma, lower extremity fracture or neurological deficit was found to be higher in incidence (p systemic condition which might be associated with decreased morbidity and mortality.

  14. Orthognathic Surgery

    DEFF Research Database (Denmark)

    Kjærgaard Larsen, Marie; Thygesen, Torben Henrik

    2016-01-01

    The literature shows that the indications for orthognathic surgery (OS) are often functional problems and unsatisfactory facial esthetics. This study investigated the esthetic outcomes and overall satisfaction following OS. Somatosensory change is a relatively common complication and its influence...... on the level of satisfaction was studied. The social-networking web site Facebook was used to identify the study population. An online questionnaire was performed using the website SurveyMonkey. In all, 105 (9%) respondents from the Danish Facebook group about OS, called Kaebeoperation (jaw surgery), were...... in beauty than women (P = 0.030). Sixty-four percent replied that their attractiveness had been increased after OS. Eighty-six percent were happy with the results and 89% would recommend the surgery to others in need. No significant differences in esthetic results and satisfaction were seen with regard...

  15. Improving esthetic results in benign parotid surgery: statistical evaluation of facelift approach, sternocleidomastoid flap, and superficial musculoaponeurotic system flap application.

    Science.gov (United States)

    Bianchi, Bernardo; Ferri, Andrea; Ferrari, Silvano; Copelli, Chiara; Sesenna, Enrico

    2011-04-01

    The purpose of this article was to analyze the efficacy of facelift incision, sternocleidomastoid muscle flap, and superficial musculoaponeurotic system flap for improving the esthetic results in patients undergoing partial parotidectomy for benign parotid tumor resection. The usefulness of partial parotidectomy is discussed, and a statistical evaluation of the esthetic results was performed. From January 1, 1996, to January 1, 2007, 274 patients treated for benign parotid tumors were studied. Of these, 172 underwent partial parotidectomy. The 172 patients were divided into 4 groups: partial parotidectomy with classic or modified Blair incision without reconstruction (group 1), partial parotidectomy with facelift incision and without reconstruction (group 2), partial parotidectomy with facelift incision associated with sternocleidomastoid muscle flap (group 3), and partial parotidectomy with facelift incision associated with superficial musculoaponeurotic system flap (group 4). Patients were considered, after a follow-up of at least 18 months, for functional and esthetic evaluation. The functional outcome was assessed considering the facial nerve function, Frey syndrome, and recurrence. The esthetic evaluation was performed by inviting the patients and a blind panel of 1 surgeon and 2 secretaries of the department to give a score of 1 to 10 to assess the final cosmetic outcome. The statistical analysis was finally performed using the Mann-Whitney U test for nonparametric data to compare the different group results. P less than .05 was considered significant. No recurrence developed in any of the 4 groups or in any of the 274 patients during the follow-up period. The statistical analysis, comparing group 1 and the other groups, revealed a highly significant statistical difference (P esthetic results in benign parotid surgery. The evaluation of functional complications and the recurrence rate in this series of patients has confirmed that this technique can be safely

  16. Systems innovation model: an integrated interdisciplinary team approach pre- and post-bariatric surgery at a veterans affairs (VA) medical center.

    Science.gov (United States)

    Eisenberg, Dan; Lohnberg, Jessica A; Kubat, Eric P; Bates, Cheryl C; Greenberg, Lauren M; Frayne, Susan M

    2017-04-01

    Provision of bariatric surgery in the Veterans Health Administration must account for obese veterans' co-morbidity burden and the geographically dispersed location of patients relative to Veterans Affairs (VA) bariatric centers. To evaluate a collaborative, integrated, interdisciplinary bariatric team of surgeons, bariatricians, psychologists, dieticians, and physical therapists working in a hub-and-spokes care model, for pre- and post-bariatric surgery assessment and management. This is a description of an interdisciplinary clinic and bariatric program at a VA healthcare system and a report on program evaluation findings. Retrospective data of a prospective database was abstracted. For program evaluation, we abstracted charts to characterize patient data and conducted a patient survey. Since 2009, 181 veterans have undergone bariatric surgery. Referrals came from 7 western U.S. states. Mean preoperative body mass index was 46 kg/m 2 (maximum 71). Mean age was 53 years, with 33% aged>60 years; 79% were male. Medical co-morbidity included diabetes (70%), hypertension (85%), and lower back or extremity joint pain (84%). A psychiatric diagnosis was present in 58%. At 12 months, follow-up was 81% and percent excess body mass index loss was 50.5%. Among 54 sequential clinic patients completing anonymous surveys, overall satisfaction with the interdisciplinary team approach and improved quality of life were high (98% and 94%, respectively). The integrated, interdisciplinary team approach using a hub-and-spokes model is well suited to the VA bariatric surgery population, with its heavy burden of medical and mental health co-morbidity and its system of geographically dispersed patients receiving treatment at specialty centers. As the VA seeks to expand the use of bariatric surgery as an option for obese veterans, interdisciplinary models crafted to address case complexity, care coordination, and long-term outcomes should be part of policy planning efforts. Published by

  17. Intestinal Surgery.

    Science.gov (United States)

    Desrochers, André; Anderson, David E

    2016-11-01

    A wide variety of disorders affecting the intestinal tract in cattle may require surgery. Among those disorders the more common are: intestinal volvulus, jejunal hemorrhage syndrome and more recently the duodenal sigmoid flexure volvulus. Although general principles of intestinal surgery can be applied, cattle has anatomical and behavior particularities that must be known before invading the abdomen. This article focuses on surgical techniques used to optimize outcomes and discusses specific disorders of small intestine. Diagnoses and surgical techniques presented can be applied in field conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  19. Anti-Mullerian hormone trend evaluation after laparoscopic surgery of monolateral endometrioma using a new dual wavelengths laser system (DWLS) for hemostasis.

    Science.gov (United States)

    Nappi, Luigi; Angioni, Stefano; Sorrentino, Felice; Cinnella, Gilda; Lombardi, Michela; Greco, Pantaleo

    2016-01-01

    Operative laparoscopy is the gold standard in the treatment of endometriotic ovarian cysts. Excisional surgery is the best technique to prevent recurrences and improve symptoms but it may result in ovarian reserve damage due to the removal of healthy ovarian cortex. The aim of this study was to assess the impact on ovarian reserve of the use of dual wavelengths laser system (DWLS) hemostasis after stripping technique of monolateral endometrioma, by dosing the anti-Mullerian hormone (AMH). This prospective study was conducted at the Institute of Obstetrics and Gynecology, University of Foggia, from December 2013 to January 2015. Forty-five women underwent excision of monolateral endometriotic ovarian cyst by stripping without using a bipolar coagulation and performing hemostasis with a DWLS. The AMH serum levels were estimated before the surgery (T0), 4-6 weeks (T1) and 6-9 months (T2) after surgery. Our results suggest that an appropriate surgical technique with the use of laser hemostasis does not determine a significant reduction of ovarian reserve. Laser hemostasis could prevent follicular reserve loss after ovarian endometrioma surgery.

  20. Update and validation of the Society for Vascular Surgery wound, ischemia, and foot infection threatened limb classification system.

    Science.gov (United States)

    Mills, Joseph L

    2014-03-01

    The diagnosis of critical limb ischemia, first defined in 1982, was intended to delineate a patient cohort with a threatened limb and at risk for amputation due to severe peripheral arterial disease. The influence of diabetes and its associated neuropathy on the pathogenesis-threatened limb was an excluded comorbidity, despite its known contribution to amputation risk. The Fontaine and Rutherford classifications of limb ischemia severity have also been used to predict amputation risk and the likelihood of tissue healing. The dramatic increase in the prevalence of diabetes mellitus and the expanding techniques of arterial revascularization has prompted modification of peripheral arterial disease classification schemes to improve outcomes analysis for patients with threatened limbs. The diabetic patient with foot ulceration and infection is at risk for limb loss, with abnormal arterial perfusion as only one determinant of outcome. The wound extent and severity of infection also impact the likelihood of limb loss. To better predict amputation risk, the Society for Vascular Surgery Lower Extremity Guidelines Committee developed a classification of the threatened lower extremity that reflects these important clinical considerations. Risk stratification is based on three major factors that impact amputation risk and clinical management: wound, ischemia, and foot infection. This classification scheme is relevant to the patient with critical limb ischemia because many are also diabetic. Implementation of the wound, ischemia, and foot infection classification system in critical limb ischemia patients is recommended and should assist the clinician in more meaningful analysis of outcomes for various forms of wound and arterial revascularizations procedures required in this challenging, patient population. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Is the Venner-PneuX Endotracheal Tube System A Cost-Effective Option For Post Cardiac Surgery Care?

    Science.gov (United States)

    Andronis, Lazaros; Oppong, Raymond A; Manga, Na'ngono; Senanayake, Eshan; Gopal, Shameer; Charman, Susan; Giri, Ramesh; Luckraz, Heyman

    2018-04-27

    Ventilator-associated pneumonia (VAP) is common and costly. In a recent randomized controlled trial, the Venner-PneuX (VPX) endotracheal tube system was found to be superior to standard endotracheal tubes (SET) in preventing VAP. However, VPX is considerably more expensive. We evaluated the costs and benefits of VPX to determine whether replacing SET with VPX is a cost-effective option for intensive care units. We developed a decision analytic model to compare intubation with VPX or SET for patients requiring mechanical ventilation post cardiac surgery. The model was populated with existing evidence on costs, effectiveness and quality of life. Cost-effectiveness and cost-utility analyses were conducted from an NHS hospital perspective. Uncertainty was assessed through deterministic and probabilistic sensitivity analyses. Compared to SET, VPX is associated with an expected cost saving of £738 per patient. VPX led to a small increase in quality-adjusted life years (QALYs), indicating that the device is overall less costly and more effective than SET. The probability of VPX being cost-effective at £30,000 per QALY is 97%. VPX would cease to be cost-effective if (i) it led to a risk reduction smaller than 0.02 compared to SET, (ii) the acquisition cost of VPX was as high as £890 or, (iii) the cost of treating a case of VAP was lower than £1,450. VPX resulted in improved outcomes and savings which far offset the cost of the device, suggesting that replacing SET with VPX is overall beneficial. Findings were robust to extreme values of key parameters. Copyright © 2018. Published by Elsevier Inc.

  2. GENERAL SURGERY

    African Journals Online (AJOL)

    surgery. Since the first laparoscopic treatment of hydatid disease was described in 1992,14 there has been a steady growth in reports of the laparoscopic treatment of hydatid cysts of liver. Although early reported laparoscopic treatment of liver hydatid disease was confined to simple drainage, more advanced laparoscopic ...

  3. GENERAL SURGERY

    African Journals Online (AJOL)

    Department of Surgery, University of Cape Town Health Sciences Faculty, Groote Schuur Hospital, Observatory, Cape Town,. South Africa ... included all district, regional and tertiary hospitals in the nine provinces. Clinics and so-called ..... large contingency of senior general surgeons from countries such as Cuba, who have ...

  4. TRAUMA SURGERY

    African Journals Online (AJOL)

    meet the criteria for damage control surgery, and ligation of the AVC is a .... There were two vertebral body fractures, one penetrating brain injury from a gunshot wound to the head, one ... two hand fractures, three haemothoraces, one pelvic fracture, .... One patient with an intimal flap injury to his left common iliac artery ...

  5. GENERAL SURGERY

    African Journals Online (AJOL)

    Schwab , using a three-phase approach.5 In 1998, Moore et al. extended the concept and described the five-stage approach.6. The aim of damage control surgery is to prevent severely injured patients from developing the “lethal triad” of hypothermia, coagulopathy and worsening acidosis, as this confers a dismal prognosis ...

  6. Rodding Surgery

    Science.gov (United States)

    ... Physical activity prior to surgery,  Length of the operation; anesthesia issues,  Reason for the choice of rod,  Time in the hospital,  Length of recovery time at home,  Pain management including control of muscle spasms,  The rehabilitation plan. ...

  7. Predictive ability of the Society for Vascular Surgery Wound, Ischemia, and foot Infection (WIfI) classification system after first-time lower extremity revascularizations

    OpenAIRE

    Darling, Jeremy; McCallum, John C.; Soden, Peter A.; Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Hamdan, A.D. (Allen D.); Verhagen, Hence; Schermerhorn, Marc

    2017-01-01

    markdownabstract__Objective:__ The Society for Vascular Surgery (SVS) Wound, Ischemia and foot Infection (WIfI) classification system was proposed to predict 1-year amputation risk and potential benefit from revascularization. Our goal was to evaluate the predictive ability of this scale in a real-world selection of patients undergoing a first-time lower extremity revascularization for chronic limb-threatening ischemia (CLTI). __Methods:__ From 2005 to 2014, 1336 limbs underwent a first-time ...

  8. Minimally invasive surgery using the open magnetic resonance imaging system combined with video-assisted thoracoscopic surgery for synchronous hepatic and pulmonary metastases from colorectal cancer: report of four cases.

    Science.gov (United States)

    Sonoda, Hiromichi; Shimizu, Tomoharu; Takebayashi, Katsushi; Ohta, Hiroyuki; Murakami, Koichiro; Shiomi, Hisanori; Naka, Shigeyuki; Hanaoka, Jun; Tani, Tohru

    2015-05-01

    Simultaneous resection of hepatic and pulmonary metastases (HPM) from colorectal cancer (CRC) has been reported to be effective, but it is also considered invasive. We report the preliminary results of performing minimally invasive surgery using the open magnetic resonance (MR) imaging system to resect synchronous HPM from CRC in four patients. All four patients were referred for thoracoscopy-assisted interventional MR-guided microwave coagulation therapy (T-IVMR-MCT) combined with video-assisted thoracoscopic surgery (VATS). The median diameters of the HPM were 18.2 and 23.2 mm, respectively. The median duration of VATS and T-IVMR-MCT was 82.5 and 139 min, respectively. All patients were discharged without any major postoperative complications. One patient was still free of disease at 24 months and the others died of disease progression 13, 36, and 47 months without evidence of recurrence in the treated area. Thus, simultaneous VATS + T-IVMR-MCT appears to be an effective option as a minimally invasive treatment for synchronous HPM from CRC.

  9. A novel remote center of motion mechanism for the force-reflective master robot of haptic tele-surgery systems.

    Science.gov (United States)

    Hadavand, Mostafa; Mirbagheri, Alireza; Behzadipour, Saeed; Farahmand, Farzam

    2014-06-01

    An effective master robot for haptic tele-surgery applications needs to provide a solution for the inversed movements of the surgical tool, in addition to sufficient workspace and manipulability, with minimal moving inertia. A novel 4 + 1-DOF mechanism was proposed, based on a triple parallelogram linkage, which provided a Remote Center of Motion (RCM) at the back of the user's hand. The kinematics of the robot was analyzed and a prototype was fabricated and evaluated by experimental tests. With a RCM at the back of the user's hand the actuators far from the end effector, the robot could produce the sensation of hand-inside surgery with minimal moving inertia. The target workspace was achieved with an acceptable manipulability. The trajectory tracking experiments revealed small errors, due to backlash at the joints. The proposed mechanism meets the basic requirements of an effective master robot for haptic tele-surgery applications. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Radio-guided occult lesion localisation using iodine-125 seeds ('ROLLIS') for removal of impalpable breast lesions: first Australian experience

    International Nuclear Information System (INIS)

    Taylor, Donna B.; Bourke, Anita G.; Westcott, Eliza

    2015-01-01

    Approximately one-third of breast cancers are impalpable and require pre-operative image-guided localisation. Hook-wire localisation (HWL) is commonly used but has several disadvantages. Use of a low-activity radioactive iodine-125 seed is a promising alternative technique used in the USA and the Netherlands. This pilot study describes the first use of this in Australia. In this prospective pilot study, 21 participants with biopsy-proven breast cancer underwent radio guided occult lesion localisation using iodine-125 seed(s) (ROLLIS) with insertion of a hook-wire for back up. Sentinel node biopsy was performed where indicated. Ease of hook-wire and seed insertion, duration of the procedure, dependence on the seed versus hook-wire during surgery, lesion location within the specimen, histopathology including size of radial margins, the ease of seed retrieval in pathology, and safe return of seeds for disposal were documented. Radiation dosimetry of staff was performed. All seeds were placed within 3.5 mm of the lesion. All lesions and seeds were removed. One participant needed re-excision for involved margins. Radiologists and surgeons both preferred ROLLIS. Surgeons were able to depend on the seed for localisation in all but one case. Sentinel node biopsy was successfully performed when required. Pathologists found seed retrieval quick and easy, with no detrimental effect on tissue processing. No radiation doses measurably above background were received by staff. ROLLIS is an easily learnt, safe and effective alternative technique to standard HWL.

  11. Effects of Addition of Systemic Tramadol or Adjunct Tramadol to Lidocaine Used for Intravenous Regional Anesthesia in Patients Undergoing Hand Surgery

    Directory of Open Access Journals (Sweden)

    Abdulkadir Yektaş

    2016-01-01

    Full Text Available Intravenous regional anesthesia (IVRA is used in outpatient hand surgery as an easily applicable and cost-effective technique with clinical advantages. The present study aimed to investigate the effects of addition of systemic tramadol or adjunct tramadol to lidocaine for IVRA in patients undergoing hand surgery. American Society of Anesthesiologists (ASA I-II patients (n=60 who underwent hand surgery were included. For this purpose, only lidocaine (LDC, lidocaine+adjunct tramadol (LDC+TRA group, or lidocaine+systemic tramadol (LDC+SysTRA group was administered to the patients for IVRA and the groups were compared in terms of onset and recovery time of sensory and motor blocks, quality of anesthesia, and the degree of intraoperative and postoperative pain. The onset time of sensorial block was significantly shorter in the LDC+TRA group than that in the LDC+SysTRA group. The motor block recovery time was significantly shorter in the LDC+SysTRA group than that in the LDC+TRA and LDC groups. Administration of tramadol as an adjunct showed some clinical benefits by providing a shorter onset time of sensory and motor block, decreasing pain and analgesic requirement, and improving intraoperative conditions during IVRA. It was determined that systemic tramadol administration had no superiority.

  12. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  13. Mortality after surgery in Europe

    DEFF Research Database (Denmark)

    Pearse, Rupert M; Moreno, Rui P; Bauer, Peter

    2012-01-01

    Clinical outcomes after major surgery are poorly described at the national level. Evidence of heterogeneity between hospitals and health-care systems suggests potential to improve care for patients but this potential remains unconfirmed. The European Surgical Outcomes Study was an international...... study designed to assess outcomes after non-cardiac surgery in Europe....

  14. Improving Quality in Colorectal Surgery

    NARCIS (Netherlands)

    J.C. Slieker (Juliette)

    2014-01-01

    markdownabstract__Abstract__ Colorectal surgery is an important aspect of our current health system, due to the high incidence of colorectal cancer combined with an ageing population, improved long-term outcomes after colorectal surgery, and the perfectioning of the operative and postoperative

  15. Robotic assisted minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Palep Jaydeep

    2009-01-01

    Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.

  16. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach

    Science.gov (United States)

    ORSARIA, PAOLO; CHIARAVALLOTI, AGOSTINO; FIORENTINI, ALESSANDRO; PISTOLESE, CHIARA; VANNI, GIANLUCA; VITTORIA GRANAI, ALESSANDRA; VARVARAS, DIMITRIOS; DANIELI, ROBERTA; SCHILLACI, ORAZIO; PETRELLA, GIUSEPPE; CLAUDIO BUONOMO, ORESTE

    2017-01-01

    Background: Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Patients and Methods: Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. Results: In all three cases, perioperative 18F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. Conclusion: This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. PMID:28064227

  17. Integrated HTA-FMEA/FMECA methodology for the evaluation of robotic system in urology and general surgery.

    Science.gov (United States)

    Frosini, Francesco; Miniati, Roberto; Grillone, Saverio; Dori, Fabrizio; Gentili, Guido Biffi; Belardinelli, Andrea

    2016-11-14

    The following study proposes and tests an integrated methodology involving Health Technology Assessment (HTA) and Failure Modes, Effects and Criticality Analysis (FMECA) for the assessment of specific aspects related to robotic surgery involving safety, process and technology. The integrated methodology consists of the application of specific techniques coming from the HTA joined to the aid of the most typical models from reliability engineering such as FMEA/FMECA. The study has also included in-site data collection and interviews to medical personnel. The total number of robotic procedures included in the analysis was 44: 28 for urology and 16 for general surgery. The main outcomes refer to the comparative evaluation between robotic, laparoscopic and open surgery. Risk analysis and mitigation interventions come from FMECA application. The small sample size available for the study represents an important bias, especially for the clinical outcomes reliability. Despite this, the study seems to confirm the better trend for robotics' surgical times with comparison to the open technique as well as confirming the robotics' clinical benefits in urology. More complex situation is observed for general surgery, where robotics' clinical benefits directly measured are the lowest blood transfusion rate.

  18. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery

    Directory of Open Access Journals (Sweden)

    Wujun Geng

    2015-01-01

    Full Text Available Objective. Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Methods. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA pump, (2 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Results. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL- 6 levels at 24 and 48 h after the operation. Conclusion. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  19. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery.

    Science.gov (United States)

    Geng, Wujun; Hong, Wandong; Wang, Junlu; Dai, Qinxue; Mo, Yunchang; Shi, Kejian; Sun, Jiehao; Qin, Jinling; Li, Mei; Tang, Hongli

    2015-01-01

    Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA) pump, (2) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3) 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL-) 6 levels at 24 and 48 h after the operation. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  20. Metabolic Surgery

    DEFF Research Database (Denmark)

    Pareek, Manan; Schauer, Philip R; Kaplan, Lee M

    2018-01-01

    The alarming rise in the worldwide prevalence of obesity is paralleled by an increasing burden of type 2 diabetes mellitus. Metabolic surgery is the most effective means of obtaining substantial and durable weight loss in individuals with obesity. Randomized trials have recently shown...... the superiority of surgery over medical treatment alone in achieving improved glycemic control, as well as a reduction in cardiovascular risk factors. The mechanisms seem to extend beyond the magnitude of weight loss alone and include improvements in incretin profiles, insulin secretion, and insulin sensitivity....... Moreover, observational data suggest that the reduction in cardiovascular risk factors translates to better patient outcomes. This review describes commonly used metabolic surgical procedures and their current indications and summarizes the evidence related to weight loss and glycemic outcomes. It further...

  1. Preparing for Surgery

    Science.gov (United States)

    ... Events Advocacy For Patients About ACOG Preparing for Surgery Home For Patients Search FAQs Preparing for Surgery ... Surgery FAQ080, August 2011 PDF Format Preparing for Surgery Gynecologic Problems What is the difference between outpatient ...

  2. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  3. Corrective Jaw Surgery

    Science.gov (United States)

    ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  4. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  5. Facial Cosmetic Surgery

    Science.gov (United States)

    ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  6. Heart bypass surgery

    Science.gov (United States)

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  7. Surgery with cooperative robots.

    Science.gov (United States)

    Lehman, Amy C; Berg, Kyle A; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Rentschler, Mark E; Platt, Stephen R; Farritor, Shane M; Oleynikov, Dmitry

    2008-03-01

    Advances in endoscopic techniques for abdominal procedures continue to reduce the invasiveness of surgery. Gaining access to the peritoneal cavity through small incisions prompted the first significant shift in general surgery. The complete elimination of external incisions through natural orifice access is potentially the next step in reducing patient trauma. While minimally invasive techniques offer significant patient advantages, the procedures are surgically challenging. Robotic surgical systems are being developed that address the visualization and manipulation limitations, but many of these systems remain constrained by the entry incisions. Alternatively, miniature in vivo robots are being developed that are completely inserted into the peritoneal cavity for laparoscopic and natural orifice procedures. These robots can provide vision and task assistance without the constraints of the entry incision, and can reduce the number of incisions required for laparoscopic procedures. In this study, a series of minimally invasive animal-model surgeries were performed using multiple miniature in vivo robots in cooperation with existing laparoscopy and endoscopy tools as well as the da Vinci Surgical System. These procedures demonstrate that miniature in vivo robots can address the visualization constraints of minimally invasive surgery by providing video feedback and task assistance from arbitrary orientations within the peritoneal cavity.

  8. The impact of surgery on global climate: a carbon footprinting study of operating theatres in three health systems.

    Science.gov (United States)

    MacNeill, Andrea J; Lillywhite, Robert; Brown, Carl J

    2017-12-01

    Climate change is a major global public health priority. The delivery of health-care services generates considerable greenhouse gas emissions. Operating theatres are a resource-intensive subsector of health care, with high energy demands, consumable throughput, and waste volumes. The environmental impacts of these activities are generally accepted as necessary for the provision of quality care, but have not been examined in detail. In this study, we estimate the carbon footprint of operating theatres in hospitals in three health systems. Surgical suites at three academic quaternary-care hospitals were studied over a 1-year period in Canada (Vancouver General Hospital, VGH), the USA (University of Minnesota Medical Center, UMMC), and the UK (John Radcliffe Hospital, JRH). Greenhouse gas emissions were estimated using primary activity data and applicable emissions factors, and reported according to the Greenhouse Gas Protocol. Site greenhouse gas evaluations were done between Jan 1 and Dec 31, 2011. The surgical suites studied were found to have annual carbon footprints of 5 187 936 kg of CO 2 equivalents (CO 2 e) at JRH, 4 181 864 kg of CO 2 e at UMMC, and 3 218 907 kg of CO 2 e at VGH. On a per unit area basis, JRH had the lowest carbon intensity at 1702 kg CO 2 e/m 2 , compared with 1951 kg CO 2 e/m 2 at VGH and 2284 kg CO 2 e/m 2 at UMMC. Based on case volumes at all three sites, VGH had the lowest carbon intensity per operation at 146 kg CO 2 e per case compared with 173 kg CO 2 e per case at JRH and 232 kg CO 2 e per case at UMMC. Anaesthetic gases and energy consumption were the largest sources of greenhouse gas emissions. Preferential use of desflurane resulted in a ten-fold difference in anaesthetic gas emissions between hospitals. Theatres were found to be three to six times more energy-intense than the hospital as a whole, primarily due to heating, ventilation, and air conditioning requirements. Overall, the carbon footprint of surgery in the

  9. Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2016-03-01

    Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model. The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09 mm (translations) and of [Formula: see text] (rotations), maximum observed errors in the order of 0.12 mm (translations) and of [Formula: see text] (rotations), and a reduction repeatability of 0.02 mm and [Formula: see text]. The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality.

  10. A CT-ultrasound-coregistered augmented reality enhanced image-guided surgery system and its preliminary study on brain-shift estimation

    International Nuclear Information System (INIS)

    Huang, C H; Hsieh, C H; Lee, J D; Huang, W C; Lee, S T; Wu, C T; Sun, Y N; Wu, Y T

    2012-01-01

    With the combined view on the physical space and the medical imaging data, augmented reality (AR) visualization can provide perceptive advantages during image-guided surgery (IGS). However, the imaging data are usually captured before surgery and might be different from the up-to-date one due to natural shift of soft tissues. This study presents an AR-enhanced IGS system which is capable to correct the movement of soft tissues from the pre-operative CT images by using intra-operative ultrasound images. First, with reconstructing 2-D free-hand ultrasound images to 3-D volume data, the system applies a Mutual-Information based registration algorithm to estimate the deformation between pre-operative and intra-operative ultrasound images. The estimated deformation transform describes the movement of soft tissues and is then applied to the pre-operative CT images which provide high-resolution anatomical information. As a result, the system thus displays the fusion of the corrected CT images or the real-time 2-D ultrasound images with the patient in the physical space through a head mounted display device, providing an immersive augmented-reality environment. For the performance validation of the proposed system, a brain phantom was utilized to simulate brain-shift scenario. Experimental results reveal that when the shift of an artificial tumor is from 5mm ∼ 12mm, the correction rates can be improved from 32% ∼ 45% to 87% ∼ 95% by using the proposed system.

  11. Comparison of the 7(th) and proposed 8(th) editions of the AJCC/UICC TNM staging system for non-small cell lung cancer undergoing radical surgery.

    Science.gov (United States)

    Jin, Ying; Chen, Ming; Yu, Xinmin

    2016-09-19

    The present study aims to compare the 7(th) and the proposed 8(th) edition of the AJCC/UICC TNM staging system for NSCLC in a cohort of patients from a single institution. A total of 408 patients with NSCLC who underwent radical surgery were analyzed retrospectively. Survivals were analyzed using the Kaplan -Meier method and were compared using the log-rank test. Multivariate analysis was performed by the Cox proportional hazard model. The Akaike information criterion (AIC) and C-index were applied to compare the two prognostic systems with different numbers of stages. The 7(th) AJCC T categories, the proposed 8(th) AJCC T categories, N categories, visceral pleural invasion, and vessel invasion were found to have statistically significant associations with disease-free survival (DFS) on univariate analysis. In the 7(th) edition staging system as well as in the proposed 8(th) edition, T categories, N categories, and pleural invasion were independent factors for DFS on multivariate analysis. The AIC value was smaller for the 8(th) edition compared to the 7(th) edition staging system. The C-index value was larger for the 8(th) edition compared to the 7(th) edition staging system. Based on the data from our single center, the proposed 8(th) AJCC T classification seems to be superior to the 7(th) AJCC T classification in terms of DFS for patients with NSCLC underwent radical surgery.

  12. Port positioning and docking for single-stage totally robotic dissection for rectal cancer surgery with the Si and Xi Da Vinci Surgical System.

    Science.gov (United States)

    Toh, James Wei Tatt; Kim, Seon-Hahn

    2017-11-04

    We have previously reported our technique of single-docking totally robotic dissection for rectal cancer surgery using the Da Vinci ® Si Surgical System in 2009. However, we have since optimised our port placement for the Si system and have developed a novel configuration of port placement and docking for the Da Vinci ® Xi Surgical System. We have performed over 700 cases using this technique with the Si system and have used our Xi technique since 2016 for totally robotic dissection for rectal cancer. We have kept the configuration of port placements for both the Xi and Si system as similar as possible, with the priorities to avoid arm collisions as well as to provide a workable port configuration of two left-handed instruments and one right-handed instrument. To date, there have had no major complications or arm collisions related to this technique of docking, port positioning and instrument placement.

  13. Success and spontaneous pregnancy rates following systemic methotrexate versus laparoscopic surgery for tubal pregnancies: A randomized trial

    DEFF Research Database (Denmark)

    Krag Moeller, Lars Bo; Moeller, Charlotte; Thomsen, Sten Grove

    2009-01-01

    . A total of 106 women diagnosed with ectopic pregnancy (EP). Methods. Between March 1997 and September 2000, 1,265 women were diagnosed with EP, 395 (31%) were eligible, 109 (9%) were randomized of whom 106 had an EP. The study was originally powered to a sample size of 422 patients. The women were......Objective. To determine which treatment should be offered to women with a non-ruptured tubal pregnancy: a single dose of methotrexate (MTX) or laparoscopic surgery. Design. Prospective, randomized, open multicenter study. Setting. Seven Danish departments of obstetrics and gynecology. Sample...... (n.s.). Conclusions. In women with an EP, who are hemodynamically stable and wishing to preserve their fertility, medical treatment with single dose MTX tends to be equal to treatment with laparoscopic surgery regarding success rate, complications, and subsequent fertility. Although the two treatment...

  14. Early mortality after neonatal surgery: analysis of risk factors in an optimized health care system for the surgical newborn

    Directory of Open Access Journals (Sweden)

    Dora Catré

    2013-12-01

    Full Text Available OBJECTIVE: Anesthetic and operative interventions in neonates remain hazardous procedures, given the vulnerability of the patients in this pediatric population. The aim was to determine the preoperative and intraoperative factors associated with 30-day post-operative mortality and describe mortality outcomes following neonatal surgery under general anesthesia in our center. METHODS: Infants less than 28 days of age who underwent general anesthesia for surgery during an 11-year period (2000 - 2010 in our tertiary care pediatric center were retrospectively identified using the pediatric intensive care unit database. Multiple logistic regression was used to identify independent preoperative and intraoperative factors associated with 30-day post-operative mortality. RESULTS: Of the 437 infants in the study (median gestational age at birth 37 weeks, median birth weight 2,760 grams, 28 (6.4% patients died before hospital discharge. Of these, 22 patients died within the first post-operative month. Logistic regression analysis showed increased odds of 30-day post-operative mortality among patients who presented American Society of Anesthesiologists physical status (ASA score 3 or above (odds ratio 19.268; 95%CI 2.523 - 147.132 and surgery for necrotizing enterocolitis/gastrointestinal perforation (OR 5.291; 95%CI 1.962 - 14.266, compared to those who did not. CONCLUSION: The overall in-hospital mortality of 6.4% is within the prevalence reported for developed countries. Establishing ASA score 3 or above and necrotizing enterocolitis/gastrointestinal perforation as independent risk factors for early mortality in neonatal surgery may help clinicians to more adequately manage this high risk population.

  15. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    Science.gov (United States)

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Corneal endothelial cell changes after cataract surgery in patients on systemic sympathetic α-1a antagonist medication (tamsulosin).

    Science.gov (United States)

    Storr-Paulsen, Allan; Jørgensen, Jesper Skovlund; Norregaard, Jens Christian; Thulesen, Jesper

    2014-06-01

      The purpose of this study was to assess the incidence of intraoperative floppy iris syndrome (IFIS) and the morphology of the corneal endothelium after cataract extraction in Caucasian male patients exposed to the α-1a adrenergic receptor antagonist tamsulosin.   In a clinical prospective study, 23 male patients (23 eyes) treated with tamsulosin due to benign prostatic hyperplasia and 25 male patients (25 eyes) with no tamsulosin treatment had cataract surgery. The divide-and-conquer technique was used with the Infinity OZil(®) machine. A combination of Healon and Healon5 was used in all patients, but the use of additional Vision Blue, iris retractors or intracameral phenylephrine in the tamsulosin group was at the discretion of the surgeon. The endothelial cell density, variation in endothelial cell size (CV), percentage of hexagonal cells and central corneal thickness (CCT) were recorded at baseline and at 3 months postoperatively.   In the tamsulosin-treated group, 19 of 23 eyes (83%) developed IFIS, compared with no IFIS in the control group. Compared with the control group, the tamsulosin group showed significantly less dilatation at the start of the operation, significant miosis during surgery and significantly greater corneal endothelial cell loss 3 months postoperatively (12% versus 3%; ptamsulosin-treated male patients. Patients on tamsulosin showed less preoperative dilatation, significant miosis during surgery, and had significantly greater postoperative endothelial cell loss compared with nontreated patients despite recommended precautions. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by Blackwell Publishing Ltd.

  17. I-gel Laryngeal Mask Airway Combined with Tracheal Intubation Attenuate Systemic Stress Response in Patients Undergoing Posterior Fossa Surgery

    Directory of Open Access Journals (Sweden)

    Chaoliang Tang

    2015-01-01

    patients. In this study, we proposed that I-gel combined with tracheal intubation could reduce the stress response of posterior fossa surgery patients. Methods. Sixty-six posterior fossa surgery patients were randomly allocated to receive either tracheal tube intubation (Group TT or I-gel facilitated endotracheal tube intubation (Group TI. Hemodynamic and respiratory variables, stress and inflammatory response, oxidative stress, anesthesia recovery parameters, and adverse events during emergence were compared. Results. Mean arterial pressure and heart rate were lower in Group TI during intubation and extubation (P<0.05 versus Group TT. Respiratory variables including peak airway pressure and end-tidal carbon dioxide tension were similar intraoperative, while plasma β-endorphin, cortisol, interleukin-6, tumor necrosis factor-alpha, malondialdehyde concentrations, and blood glucose were significantly lower in Group TI during emergence relative to Group TT. Postoperative bucking and serious hypertensions were seen in Group TT but not in Group TI. Conclusion. Utilization of I-gel combined with endotracheal tube in posterior fossa surgery patients is safe which can yield more stable hemodynamic profile during intubation and emergence and lower inflammatory and oxidative response, leading to uneventful recovery.

  18. KinoHaptics: An Automated, Wearable, Haptic Assisted, Physio-therapeutic System for Post-surgery Rehabilitation and Self-care.

    Science.gov (United States)

    Rajanna, Vijay; Vo, Patrick; Barth, Jerry; Mjelde, Matthew; Grey, Trevor; Oduola, Cassandra; Hammond, Tracy

    2016-03-01

    A carefully planned, structured, and supervised physiotherapy program, following a surgery, is crucial for the successful diagnosis of physical injuries. Nearly 50 % of the surgeries fail due to unsupervised, and erroneous physiotherapy. The demand for a physiotherapist for an extended period is expensive to afford, and sometimes inaccessible. Researchers have tried to leverage the advancements in wearable sensors and motion tracking by building affordable, automated, physio-therapeutic systems that direct a physiotherapy session by providing audio-visual feedback on patient's performance. There are many aspects of automated physiotherapy program which are yet to be addressed by the existing systems: a wide classification of patients' physiological conditions to be diagnosed, multiple demographics of the patients (blind, deaf, etc.), and the need to pursue patients to adopt the system for an extended period for self-care. In our research, we have tried to address these aspects by building a health behavior change support system called KinoHaptics, for post-surgery rehabilitation. KinoHaptics is an automated, wearable, haptic assisted, physio-therapeutic system that can be used by a wide variety of demographics and for various physiological conditions of the patients. The system provides rich and accurate vibro-haptic feedback that can be felt by the user, irrespective of the physiological limitations. KinoHaptics is built to ensure that no injuries are induced during the rehabilitation period. The persuasive nature of the system allows for personal goal-setting, progress tracking, and most importantly life-style compatibility. The system was evaluated under laboratory conditions, involving 14 users. Results show that KinoHaptics is highly convenient to use, and the vibro-haptic feedback is intuitive, accurate, and has shown to prevent accidental injuries. Also, results show that KinoHaptics is persuasive in nature as it supports behavior change and habit building

  19. Cost feasibility of a pre-checking medical tourism system for U.S. patients undertaking joint replacement surgery in Taiwan.

    Science.gov (United States)

    Haung, Ching-Ying; Wang, Sheng-Pen; Chiang, Chih-Wei

    2010-01-01

    Medical tourism is a relatively recent global economic and political phenomenon that has assumed increasing importance for developing countries, particularly in Asia. In fact, Taiwan possesses a niche for developing medical tourism because many hospitals provide state-of-the-art medicine in all disciplines and many doctors are trained in the United States (US). Among the most common medical procedures outsourced, joint replacements such as total knee replacement (TKR) and total hip replacement (THR) are two surgeries offered to US patients at a lower cost and shorter waiting time than in the US. This paper proposed a pre-checking medical tourism system (PCMTS) and evaluated the cost feasibility of recruiting American clients traveling to Taiwan for joint replacement surgery. Cost analysis was used to estimate the prime costs for each stage in the proposed PCMTS. Sensitivity analysis was implemented to examine how different pricings for medical checking and a surgical operation (MC&SO) and recovery, can influence the surplus per patient considering the PCMTS. Finally, the break-even method was adopted to test the tradeoff between the sunk costs of investment in the PCMTS and the annual surplus for participating hospitals. A novel business plan was built showing that pre-checking stations in medical tourism can provide post-operative care and recovery follow-up. Adjustable pricing for hospital administrators engaged in the PCMTS consisted of two main costs: US$3,700 for MC&SO and US$120 for the hospital stay. Guidelines for pricing were provided to maximize the annual surplus from this plan with different number of patients participating in PCMTS. The maximal profit margin from each American patient undertaking joint surgery is about US$24,315. Using cost analysis, this article might be the first to evaluate the feasibility of PCMTS for joint replacement surgeries. The research framework in this article is applicable when hospital administrators evaluate the

  20. Experience with FreeStyle Libre Flash glucose monitoring system in management of refractory dumping syndrome in pregnancy shortly after bariatric surgery

    Directory of Open Access Journals (Sweden)

    Peter Novodvorsky

    2017-12-01

    Full Text Available Bariatric surgery is an effective therapy for obesity but is associated with long-term complications such as dumping syndromes and nutritional deficiencies. We report a case of a 26-year-old caucasian female, with history of morbid obesity and gestational diabetes (GDM, who became pregnant 4 months after Roux-en-Y bypass surgery. She developed GDM during subsequent pregnancy, which was initially managed with metformin and insulin. Nocturnal hypoglycaemia causing sleep disturbance and daytime somnolence occured at 19 weeks of pregnancy (19/40. Treatment with rapid-acting carbohydrates precipitated further hypoglycaemia. Laboratory investigations confirmed hypoglycaemia at 2.2 mmol/L with appropriately low insulin and C-peptide, intact HPA axis and negative IgG insulin antibodies. The patient was seen regularly by the bariatric dietetic team but concerns about compliance persisted. A FreeStyle Libre system was used from 21/40 enabling the patient a real-time feedback of changes in interstitial glucose following high or low GI index food intake. The patient declined a trial of acarbose but consented to an intraveneous dextrose infusion overnight resulting in improvement but not complete abolishment of nocturnal hypoglycaemia. Hypoglycaemias subsided at 34/40 and metformin and insulin had to be re-introduced due to high post-prandial blood glucose readings. An emergency C-section was indicated at 35 + 1/40 and a small-for-gestational-age female was delivered. There have been no further episodes of hypoglycaemia following delivery. This case illustrates challenges in the management of pregnancy following bariatric surgery. To our knowledge, this is the first use of FreeStyle Libre in dumping syndrome in pregnancy following bariatric surgery with troublesome nocturnal hypoglycaemia.

  1. Robotic Transnasal Endoscopic Skull Base Surgery: Systematic Review of the Literature and Report of a Novel Prototype for a Hybrid System (Brescia Endoscope Assistant Robotic Holder).

    Science.gov (United States)

    Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo

    2017-09-01

    Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Self-nanoemulsifying drug delivery systems ameliorate the oral delivery of silymarin in rats with Roux-en-Y gastric bypass surgery

    Directory of Open Access Journals (Sweden)

    Chen CH

    2015-03-01

    Full Text Available Chun-Han Chen,1,2 Cheng-Chih Chang,1 Tsung-Hsien Shih,2 Ibrahim A Aljuffali,3 Ta-Sen Yeh,4,5 Jia-You Fang6–8 1Division of General Surgery, Department of Surgery, Chang Gung Memorial Hospital, Chiayi, 2Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Kweishan, Taoyuan, Taiwan; 3Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia; 4Department of Surgery, Chang Gung Memorial Hospital, 5School of Medicine, College of Medicine, 6Pharmaceutics Laboratory, Graduate Institute of Natural Products, 7Chinese Herbal Medicine Research Team, Healthy Aging Research Center, Chang Gung University, 8Research Center for Industry of Human Ecology, Chang Gung University of Science and Technology, Kweishan, Taoyuan, Taiwan Abstract: Roux-en-Y gastric bypass (RYGB is a popular surgery to reduce the body weight of obese patients. Although food intake is restricted by RYGB, drug absorption is also decreased. The purpose of this study was to develop novel self-nanoemulsifying drug delivery systems (SNEDDS for enhancing the oral delivery of silymarin, which has poor water solubility. The SNEDDS were characterized by size, zeta potential, droplet number, and morphology. A technique of RYGB was performed in Sprague-Dawley rats. SNEDDS were administered at a silymarin dose of 600 mg/kg in normal and RYGB rats for comparison with silymarin aqueous suspension and polyethylene glycol (PEG 400 solution. Plasma silibinin, the main active ingredient in silymarin, was chosen for estimating the pharmacokinetic parameters. SNEDDS diluted in simulated gastric fluid exhibited a droplet size of 190 nm with a spherical shape. The nanocarriers promoted silibinin availability via oral ingestion in RYGB rats by 2.5-fold and 1.5-fold compared to the suspension and PEG 400 solution, respectively. A significant double-peak concentration of silibinin was detected for RYGB rats receiving SNEDDS. Fluorescence

  3. [Quality of case allocation of orthopedics and trauma surgery in the 2004 and 2014 versions of the German DRG system. An interim assessment of the development process].

    Science.gov (United States)

    Franz, D; Schemmann, F; Selter, D D; Auhuber, T; Gehweiler, D; Roeder, N; Siebert, H; Mahlke, L

    2014-10-01

    Since 2004 the German diagnosis-related groups (DRG) system has been applied nationwide in all German somatic hospitals. The G-DRG system is updated annually in order to increase the quality of case allocation. What developments have occurred since 2004 from the perspective of orthopedics and trauma surgery? This article takes stock of the developments between 2004 and 2014. Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2004 and 2014 based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). The number of G-DRGs in the whole system increased by 45.1 % between 2004 and 2014. The number of G-DRGs in the major diagnostic category (MDC) 08 that contains the majority of orthopedic and trauma surgery categories increased in the same period by 61.6 %. The reduction of variance of inlier costs in the MDC 08 category, a statistical measure of the performance of the G-DRG system, was below the corresponding value of the total system in 2004 as well in 2014. However, the reduction of variance of inlier costs in MDC 08 (+ 30.0 %) rose more from 2004 to 2014 than the corresponding value of the overall system (+ 21.5 %). Many modifications of the classification systems of diagnoses (ICD-10-GM) and medical procedures (OPS) and the structures of the G-DRG system could significantly improve the quality of case allocation from the perspective of orthopedics and trauma surgery between 2004 and 2014. Th assignment of cases could be differentiated so that complex cases with more utilization of resources were allocated to higher rated G-DRGs and vice versa. However, further improvements of the G-DRG system are necessary. Only correct and complete documentation and coding can provide a high quality of calculation of costs as a basis for a correct case allocation in future G-DRG systems.

  4. Postoperative cognitive dysfunction and neuroinflammation; Cardiac surgery and abdominal surgery are not the same

    NARCIS (Netherlands)

    Hovens, Iris B.; van Leeuwen, Barbara L.; Mariani, Massimo A.; Kraneveld, Aletta D.; Schoemaker, Regien G.

    Postoperative cognitive dysfunction (POCD) is a debilitating surgical complication, with cardiac surgery patients at particular risk. To gain insight in the mechanisms underlying the higher incidence of POCD after cardiac versus non-cardiac surgery, systemic and central inflammatory changes,

  5. FY1995 development of highly qualified less invasive surgery system; 1995 nendo higly qualified LIS (teishinshu geka shujutsu) system no sogoteki kaihatsu kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The risk of complications related to high pressure pneumo-peritoneum as well as the restrictions applied to the maneuvering limit further development of laparoscope surgery in various fields. To eliminate such restrictions, we developed the original method of gasless laparoscopic surgery, namely the abdominal wall lifting with double subcutaneous wiring and adjustable plate lifting. These include (1) the ceiling and the lateral wall is much higher and wider than the pneumoperitoneal method (2) less post-operative pain due to non-injury of nerves and muscle layers, and (3) the shape of lifting area and the lifting direction can be adjusted for different cases, and (4) ability to perform extremely difficult cases of severe intraabdominal adhesions. The ultimate goal of this research project is the achievement of truly safe and secure operative method of minimally invasive surgery. Some of the new laparoscopic instruments we invented include the 'Ojigi' rotatable spatula, several motor forceps and sensory forceps. In gasless laparoscopic surgery, the effective intraabdominal space creation is done by the abdominal wall lifting with double subcutaneous wiring and adjustable plate lifting. In addition, the newly developed rotatable operating table is extremely effective in maximizing the intraabdominal space. To improve the visual quality of laparoscope surgery, we developed several advanced cameras which take advantages of high definition TV and three dimensional display. (NEDO)

  6. Is hospital information system relevant to detect surgical site infection? Findings from a prospective surveillance study in posterior instrumented spinal surgery.

    Science.gov (United States)

    Boetto, J; Chan-Seng, E; Lonjon, G; Pech, J; Lotthé, A; Lonjon, N

    2015-11-01

    Spinal instrumentation has a high rate of surgical site infection (SSI), but results greatly vary depending on surveillance methodology, surgical procedures, or quality of follow-up. Our aim was to study true incidence of SSI in spinal surgery by significant data collection, and to compare it with the results obtained through the hospital information system. This work is a single center prospective cohort study that included all patients consecutively operated on for spinal instrumentation by posterior approach over a six-month period regardless the etiology. For all patients, a "high definition" prospective method of surveillance was performed by the infection control (IC) department during at least 12 months after surgery. Results were then compared with findings from automatic surveillance though the hospital information system (HIS). One hundred and fifty-four patients were included. We found no hardly difference between "high definition" and automatic surveillance through the HIS, even if HIS tended to under-estimate the infection rate: rate of surgical site infection was 2.60% and gross SSI incidence rate via the hospital information system was 1.95%. Smoking and alcohol consumption were significantly related to a SSI. Our SSI rates to reflect the true incidence of infectious complications in posterior instrumented adult spinal surgery in our hospital and these results were consistent with the lower levels of published infection rate. In-house surveillance by surgeons only is insufficiently sensitive. Further studies with more patients and a longer inclusion time are needed to conclude if SSI case detection through the HIS could be a relevant and effective alternative method. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. [Computer assisted orthognathic surgery: Condyle repositioning.

    Science.gov (United States)

    Bettega, G; Leitner, F

    2013-07-17

    Computer aided surgery has become a standard in many fields. It is rarely used in orthognathic surgery. Twenty years ago, we developed a navigation system adapted to this surgery, especially for mandibular condyle repositioning. The system has been improved along with technological progress. The authors of several clinical studies have validated this system. It is now routinely used in our department, because of its educational virtues among other assets. Copyright © 2013. Published by Elsevier Masson SAS.

  8. Introspection into institutional database allows for focused quality improvement plan in cardiac surgery: example for a new global healthcare system.

    Science.gov (United States)

    Lancaster, Elizabeth; Postel, Mackenzie; Satou, Nancy; Shemin, Richard; Benharash, Peyman

    2013-10-01

    Reducing readmission rates is vital to improving quality of care and reducing healthcare costs. In accordance with the Patient Protection and Affordable Care Act, Medicare will cut payments to hospitals with high 30-day readmission rates. We retrospectively reviewed an institutional database to identify risk factors predisposing adult cardiac surgery patients to rehospitalization within 30 days of discharge. Of 2302 adult cardiac surgery patients within the study period from 2008 to 2011, a total of 218 patients (9.5%) were readmitted within 30 days. Factors found to be significant predictors of readmission were nonwhite race (P = 0.003), government health insurance (P = 0.02), ejection fraction less than 40 per cent (P = 0.001), chronic lung disease (P improving patient care. Our data suggest that optimizing cardiopulmonary status in patients with comorbidities such as heart failure and chronic obstructive pulmonary disease, increasing directed pneumonia prophylaxis, patient education tailored to specific patient social needs, earlier patient follow-up, and better communication between inpatient and outpatient physicians may reduce readmission rates.

  9. Comparison between magnetic anchoring and guidance system camera-assisted laparoendoscopic single-site surgery nephrectomy and conventional laparoendoscopic single-site surgery nephrectomy in a porcine model: focus on ergonomics and workload profiles.

    Science.gov (United States)

    Han, Woong Kyu; Tan, Yung K; Olweny, Ephrem O; Yin, Gang; Liu, Zhuo-Wei; Faddegon, Stephen; Scott, Daniel J; Cadeddu, Jeffrey A

    2013-04-01

    To compare surgeon-assessed ergonomic and workload demands of magnetic anchoring and guidance system (MAGS) laparoendoscopic single-site surgery (LESS) nephrectomy with conventional LESS nephrectomy in a porcine model. Participants included two expert and five novice surgeons who each performed bilateral LESS nephrectomy in two nonsurvival animals using either the MAGS camera or conventional laparoscope. Task difficulty and workload demands of the surgeon and camera driver were assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Surgeons were also asked to score 6 parameters on a Likert scale (range 1=low/easy to 5=high/hard): procedure-associated workload, ergonomics, technical challenge, visualization, accidental events, and instrument handling. Each step of the nephrectomy was also timed and instrument clashing was quantified. Scores for each parameter on the Likert scale were significantly lower for MAGS-LESS nephrectomy. Mean number of internal and external clashes were significantly lower for the MAGS camera (pNASA-TLX workload ratings by the surgeon and camera driver showed that MAGS resulted in a significantly lower workload than the conventional laparoscope during LESS nephrectomy (p<0.05). The use of the MAGS camera during LESS nephrectomy lowers the task workload for both the surgeon and camera driver when compared to conventional laparoscope use. Subjectively, it appears to also improve surgeons' impressions of ergonomics and technical challenge. Pending approval for clinical use, further evaluation in the clinical setting is warranted.

  10. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  11. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  12. Gastric Sleeve Surgery

    Science.gov (United States)

    ... Videos for Educators Search English Español Gastric Sleeve Surgery KidsHealth / For Teens / Gastric Sleeve Surgery What's in ... or buying healthy food ) Preparing for Gastric Sleeve Surgery Preparing for this major operation takes months of ...

  13. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  14. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  15. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  16. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Oral Surgeries Facial Cosmetic Surgery Facial Injury / Trauma Surgery Obstructive Sleep Apnea (OSA) Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ...

  17. EnViSoRS: Enhanced Vision System for Robotic Surgery. A User-Defined Safety Volume Tracking to Minimize the Risk of Intraoperative Bleeding

    Directory of Open Access Journals (Sweden)

    Veronica Penza

    2017-05-01

    Full Text Available In abdominal surgery, intraoperative bleeding is one of the major complications that affect the outcome of minimally invasive surgical procedures. One of the causes is attributed to accidental damages to arteries or veins, and one of the possible risk factors falls on the surgeon’s skills. This paper presents the development and application of an Enhanced Vision System for Robotic Surgery (EnViSoRS, based on a user-defined Safety Volume (SV tracking to minimize the risk of intraoperative bleeding. It aims at enhancing the surgeon’s capabilities by providing Augmented Reality (AR assistance toward the protection of vessels from injury during the execution of surgical procedures with a robot. The core of the framework consists in (i a hybrid tracking algorithm (LT-SAT tracker that robustly follows a user-defined Safety Area (SA in long term; (ii a dense soft tissue 3D reconstruction algorithm, necessary for the computation of the SV; (iii AR features for visualization of the SV to be protected and of a graphical gage indicating the current distance between the instruments and the reconstructed surface. EnViSoRS was integrated with a commercial robotic surgical system (the dVRK system for testing and validation. The experiments aimed at demonstrating the accuracy, robustness, performance, and usability of EnViSoRS during the execution of a simulated surgical task on a liver phantom. Results show an overall accuracy in accordance with surgical requirements (<5 mm, and high robustness in the computation of the SV in terms of precision and recall of its identification. The optimization strategy implemented to speed up the computational time is also described and evaluated, providing AR features update rate up to 4 fps, without impacting the real-time visualization of the stereo endoscopic video. Finally, qualitative results regarding the system usability indicate that the proposed system integrates well with the commercial surgical robot and

  18. Family systems ideas in the 10-minute consultation: using a reflecting partner or observing team in a surgery.

    Science.gov (United States)

    Mayer, R; Graham, H; Schuberth, C; Launer, J; Tomson, D; Czauderna, J

    1996-04-01

    Family therapy and the ideas that underlie it have not had much impact on general practice, although there is good reason to think this could be a useful approach. As a group of general practitioners (and a practice nurse) with experience of family therapy, we were interested in demonstrating whether family therapy methods could usefully inform general practice consultations. Two surgeries were observed by the general practitioner's colleagues. Selected cases are discussed to illustrate the impact of the use of family therapy ideas and a reflecting colleague or team. Family therapy ideas can be a helpful framework within which to think about both demanding and ordinary consultations. Inviting a colleague to contribute respectfully could be useful both as a method of teaching, and in resolving difficult or faltering consultations.

  19. Differences in energy expenditure for conventional and femtosecond-assisted cataract surgery using 2 different phacoemulsification systems.

    Science.gov (United States)

    Yesilirmak, Nilufer; Diakonis, Vasilios F; Sise, Adam; Waren, Daniel P; Yoo, Sonia H; Donaldson, Kendall E

    2017-01-01

    To compare the mean cumulative dissipated energy (CDE) in patients having femtosecond laser-assisted or conventional phacoemulsification cataract surgery using 2 different phacoemulsification platforms. Bascom Palmer Eye Institute, Miami, Florida, USA. Prospective comparative nonrandomized clinical study. Consecutive patients were scheduled to have femtosecond laser-assisted cataract surgery with the Lensx laser or conventional phacoemulsification using an active-fluidics torsional platform (Centurion) or torsional platform (Infiniti). The mean CDE and cataract grade were recorded. The study comprised 570 eyes (570 patients). There was no statistically significant difference in mean age (P = .41, femtosecond group; P = .33, conventional group) or cataract grade (P = .78 and P = .45, respectively) between the active-fluidics and gravity-fluidics platforms. In femtosecond cases (145 eyes), the mean CDE (percent-seconds) was 5.18 ± 4.58 (SD) with active fluidics and 7.00 ± 6.85 with gravity fluidics; in conventional cases (425 eyes), the mean CDE was 7.77 ± 6.97 and 11.43 ± 9.12, respectively. In both femtosecond cases and conventional cases, the CDE was lower with the active-fluidics platform than with the gravity-fluidics platform (P = .029, femtosecond group; P < .001 conventional group). With both fluidics platforms, the mean CDE was significantly lower in the femtosecond group than in the conventional group (both P < .001). The active-fluidics phacoemulsification platform achieved lower CDE values than the gravity-fluidics platform for conventional cataract extraction. Femtosecond laser pretreatment with the active-fluidics platform further reduced CDE. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Breast Reduction Surgery

    Science.gov (United States)

    ... considering breast reduction surgery, consult a board-certified plastic surgeon. It's important to understand what breast reduction surgery entails — including possible risks and complications — as ...

  1. The Role of Radio Frequency Detection System Embedded Surgical Sponges in Preventing Retained Surgical Sponges: A Prospective Evaluation in Patients Undergoing Emergency Surgery.

    Science.gov (United States)

    Inaba, Kenji; Okoye, Obi; Aksoy, Hande; Skiada, Dimitra; Ault, Glenn; Sener, Stephen; Lam, Lydia; Benjamin, Elizabeth; Demetriades, Demetrios

    2016-10-01

    To prospectively evaluate the ability of radio frequency detection (RFD) system-embedded sponges to mitigate the incidence of retained surgical sponges (RSS) after emergency surgery. Emergency surgery patients are at high risk for retained foreign bodies. All emergent trauma and nontrauma cavitary operations over a 5-year period (January 2010-December 2014) were prospectively enrolled. For damage-control procedures, only the definitive closure was included. RFD sponges were used exclusively throughout the study period. Before closure, the sponge and instrument count was followed by RFD scanning and x-ray evaluation for retained sponges. RSS and near-misses averted using the RFD system were analyzed. In all, 2051 patients [median (range)], aged 41 (1-101) years, 72.2% male, 46.8% trauma patients, underwent 2148 operations (1824 laparotomy, 100 thoracotomy, 30 sternotomy, and 97 combined). RFD detected retained sponges in 11 (0.5%) patients (81.8%laparotomy, 18.2% sternotomy) before cavitary closure. All postclosure x-rays were negative. No retained sponges were missed by the RFD system. Body mass index was 29 (23-43), estimated blood loss 1.0 L (0-23), and operating room time 160 minutes (71-869). Procedures started after 18:00 to 06:00 hours in 45.5% of the patients. The sponge count was incorrect in 36.4%, not performed due to time constraints in 45.5%, and correct in 18.2%. The additional cost of using RFD-embedded disposables was $0.17 for a 4X18 laparotomy sponge and $0.46 for a 10 pack of 12ply, 4X8. Emergent surgical procedures are high-risk for retained sponges, even when sponge counts are performed and found to be correct. Implementation of a RFD system was effective in preventing this complication and should be considered for emergent operations in an effort to improve patient safety.

  2. Cell response to surgery.

    LENUS (Irish Health Repository)

    Ni Choileain, Niamh

    2012-02-03

    OBJECTIVES: To describe the profound alterations in host immunity that are produced by major surgery as demonstrated by experimental and clinical studies, and to evaluate the benefits of therapeutic strategies aimed at attenuating perioperative immune dysfunction. DATA SOURCES: A review of the English-language literature was conducted, incorporating searches of the MEDLINE, EMBASE, and Cochrane collaboration databases to identify laboratory and clinical studies investigating the cellular response to surgery. STUDY SELECTION: Original articles and case reports describing immune dysfunction secondary to surgical trauma were included. DATA EXTRACTION: The results were compiled to show outcomes of different studies and were compared. DATA SYNTHESIS: Current evidence indicates that the early systemic inflammatory response syndrome observed after major surgery that is characterized by proinflammatory cytokine release, microcirculatory disturbance, and cell-mediated immune dysfunction is followed by a compensatory anti-inflammatory response syndrome, which predisposes the patient to opportunistic infection, multiple organ dysfunction syndrome, and death. Because there are currently no effective treatment options for multiple organ dysfunction syndrome, measures to prevent its onset should be initiated at an early stage. Accumulating experimental evidence suggests that targeted therapeutic strategies involving immunomodulatory agents such as interferon gamma, granulocyte colony-stimulating factor, the prostaglandin E(2) antagonist, indomethacin, and pentoxifylline may be used for the treatment of systemic inflammatory response syndrome to prevent the onset of multiple organ dysfunction syndrome. CONCLUSIONS: Surgical trauma produces profound immunological dysfunction. Therapeutic strategies directed at restoring immune homeostasis should aim to redress the physiological proinflammatory-anti-inflammatory cell imbalance associated with major surgery.

  3. Cardiovascular and respiratory changes and convalescence in laparoscopic colonic surgery

    DEFF Research Database (Denmark)

    Schulze, S; Lyng, K M; Bugge, K

    1999-01-01

    Gasless laparoscopy produces smaller cardiopulmonary and systemic changes than carbon dioxide (CO2) laparoscopy during colonic surgery.......Gasless laparoscopy produces smaller cardiopulmonary and systemic changes than carbon dioxide (CO2) laparoscopy during colonic surgery....

  4. Performance of the European System for Cardiac Operative Risk Evaluation II: a meta-analysis of 22 studies involving 145,592 cardiac surgery procedures.

    Science.gov (United States)

    Guida, Pietro; Mastro, Florinda; Scrascia, Giuseppe; Whitlock, Richard; Paparella, Domenico

    2014-12-01

    A systematic review of the European System for Cardiac Operative Risk Evaluation (euroSCORE) II performance for prediction of operative mortality after cardiac surgery has not been performed. We conducted a meta-analysis of studies based on the predictive accuracy of the euroSCORE II. We searched the Embase and PubMed databases for all English-only articles reporting performance characteristics of the euroSCORE II. The area under the receiver operating characteristic curve, the observed/expected mortality ratio, and observed-expected mortality difference with their 95% confidence intervals were analyzed. Twenty-two articles were selected, including 145,592 procedures. Operative mortality occurred in 4293 (2.95%), whereas the expected events according to euroSCORE II were 4802 (3.30%). Meta-analysis of these studies provided an area under the receiver operating characteristic curve of 0.792 (95% confidence interval, 0.773-0.811), an estimated observed/expected ratio of 1.019 (95% confidence interval, 0.899-1.139), and observed-expected difference of 0.125 (95% confidence interval, -0.269 to 0.519). Statistical heterogeneity was detected among retrospective studies including less recent procedures. Subgroups analysis confirmed the robustness of combined estimates for isolated valve procedures and those combined with revascularization surgery. A significant overestimation of the euroSCORE II with an observed/expected ratio of 0.829 (95% confidence interval, 0.677-0.982) was observed in isolated coronary artery bypass grafting and a slight underestimation of predictions in high-risk patients (observed/expected ratio 1.253 and observed-expected difference 1.859). Despite the heterogeneity, the results from this meta-analysis show a good overall performance of the euroSCORE II in terms of discrimination and accuracy of model predictions for operative mortality. Validation of the euroSCORE II in prospective populations needs to be further studied for a continuous

  5. A Fast-Track Referral System for Skin Lesions Suspicious of Melanoma: Population-Based Cross-Sectional Study from a Plastic Surgery Center

    Directory of Open Access Journals (Sweden)

    Reem Dina Jarjis

    2016-01-01

    Full Text Available Introduction. To minimize delay between presentation, diagnosis, and treatment of cutaneous melanoma (CM, a national fast-track referral system (FTRS was implemented in Denmark. The aim of this study was to analyze the referral patterns to our department of skin lesions suspicious of melanoma in the FTRS. Methods. Patients referred to the Department of Plastic Surgery and Breast Surgery in Zealand University Hospital were registered prospectively over a 1-year period in 2014. A cross-sectional study was performed analyzing referral patterns, including patient and tumor characteristics. Results. A total of 556 patients were registered as referred to the center in the FTRS for skin lesions suspicious of melanoma. Among these, a total of 312 patients (56.1% were diagnosed with CM. Additionally, 41 (7.4% of the referred patients were diagnosed with in situ melanoma. Conclusion. In total, 353 (63.5% patients had a malignant or premalignant melanocytic skin lesion. When only considering patients who where referred without a biopsy, the diagnostic accuracy for GPs and dermatologists was 29% and 45%, respectively. We suggest that efforts of adequate training for the referring physicians in diagnosing melanocytic skin lesions will increase diagnostic accuracy, leading to larger capacity in secondary care for the required treatment of malignant skin lesions.

  6. [Systemic Antimicrobials Consumption and Expenditures in Departments of Surgery of Multi-Profile Hospitals in the Russian Federation and the Republic of Belarus: Results of Multicentre Pharmacoepidemiological Study].

    Science.gov (United States)

    Belkova, Yu A; Rachina, S A; Kozlov, R S; Mishchenko, V M; Pavlukov, R A; Abubakirova, A I; Berezhanskiy, B V; Eliseeva, E V; Zubareva, N A; Karpov, I A; Kopylova, I A; Palyutin, Sh Kh; Portnyagina, U S; Pribytkova, O V; Samuylo, E K

    2016-01-01

    The results of the systemic antimicrobials (AM) consumption and expenditures assessment in the departments of surgery of multi-profile hospitals in different regions of the Russian Federation and the Republic of Belarus in 2009-2010 based on retrospective collection and analysis of the data from the hospital expenditure notes using ATC/DDD methodology are presented. The average AM consumption and expenditure rates in the above mentioned departments varied from 24.9 DDD/100 bed-days to 61.7 DDD/100 bed-days depending on the department profile, with beta-lactams (cephalosporins and penicillins) share in the consumption being as high as 70-90%, followed by fluoroquinolones and aminoglycosides. Only 55-70% of the consumed AM belonged to the drugs of choice, whereas the improper AM consumption and expenditure rates amounted up to 10-18%. The study outputs can be used for the budget allocation and AM distribution improvement in the departments of surgery, as well as for the development and efficacy control of the local antimicrobial stewardship programs.

  7. [Financial analysis of a department of general surgery in a French hospital. The new "fee-for-service" reimbursement system results in a high deficit for emergency care].

    Science.gov (United States)

    Burdy, G; Dalban-Sillas, B; Leclerc, C; Bonnaventure, F; Roullet Audy, J-C; Frileux, P

    2009-10-01

    The aim of this study was to perform a detailed analysis of income and expense in a department of general surgery in a French hospital under the new system of funding based on a "fee-for-service" principle. All hospital stays of year 2006 were analysed retrospectively. The conditions of admission (elective vs. emergency), the principal diagnosis, and surgical procedures were examined. We determined hospital costs and the reimbursement for every admission. One thousand nine hundred and eighty-five hospitalizations generated an income of 8Meuros with a deficit of 1.3Meuros. The 775 elective admissions generated 50% of the income and 13% of the deficit (178,562euros). Seven hundred and forty-nine emergency admissions generated 45% of the income and 82% of deficit (1.1Meuros). Four hundred and sixty-one admissions for endoscopy generated 5% of the income and 5% of the deficit (67,249euros). Hospital stays of less than two days (the minimum duration of stay for total reimbursement) caused a loss of 122,624euros. Length of hospital stay below the lower limit caused a loss of 42,850euros. Elective surgical activity in digestive surgery can generate a balanced budget provided the length of hospital stay is reduced to the minimum, sometimes to the detriment of patient comfort. Emergency admissions result in a large deficit between cost and reimbursement; this fact may lead hospitals to avoid emergency activity in the future unless appropriate remedial measures are taken.

  8. Development of an in vivo visual robot system with a magnetic anchoring mechanism and a lens cleaning mechanism for laparoendoscopic single-site surgery (LESS).

    Science.gov (United States)

    Feng, Haibo; Dong, Dinghui; Ma, Tengfei; Zhuang, Jinlei; Fu, Yili; Lv, Yi; Li, Liyi

    2017-12-01

    Surgical robot systems which can significantly improve surgical procedures have been widely used in laparoendoscopic single-site surgery (LESS). For a relative complex surgical procedure, the development of an in vivo visual robot system for LESS can effectively improve the visualization for surgical robot systems. In this work, an in vivo visual robot system with a new mechanism for LESS was investigated. A finite element method (FEM) analysis was carried out to ensure the safety of the in vivo visual robot during the movement, which was the most important concern for surgical purposes. A master-slave control strategy was adopted, in which the control model was established by off-line experiments. The in vivo visual robot system was verified by using a phantom box. The experiment results show that the robot system can successfully realize the expected functionalities and meet the demands of LESS. The experiment results indicate that the in vivo visual robot with high manipulability has great potential in clinical application. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Prevention of hypothermia in patients undergoing orthotopic liver transplantation using the humigard® open surgery humidification system: a prospective randomized pilot and feasibility clinical trial.

    Science.gov (United States)

    Weinberg, Laurence; Huang, Andrew; Alban, Daniel; Jones, Robert; Story, David; McNicol, Larry; Pearce, Brett

    2017-01-23

    Perioperative thermal disturbances during orthotopic liver transplantation (OLT) are common. We hypothesized that in patients undergoing OLT the use of a humidified high flow CO 2 warming system maintains higher intraoperative temperatures when compared to standardized multimodal strategies to maintain thermoregulatory homeostasis. We performed a randomized pilot study in adult patients undergoing primary OLT. Participants were randomized to receive either open wound humidification with a high flow CO 2 warming system in addition to standard care (Humidification group) or to standard care alone (Control group). The primary end point was nasopharyngeal core temperature measured 5 min immediately prior to reperfusion of the donor liver (Stage 3 - 5 min). Secondary endpoints included intraoperative PaCO 2 , minute ventilation and the use of vasoconstrictors. Eleven patients were randomized to each group. Both groups were similar for age, body mass index, MELD, SOFA and APACHE II scores, baseline temperature, and duration of surgery. Immediately prior to reperfusion (Stage 3 - 5 min) the mean (SD) core temperature was higher in the Humidification Group compared to the Control Group: 36.0 °C (0.13) vs. 35.4 °C (0.22), p = 0.028. Repeated measured ANOVA showed that core temperatures over time during the stages of the transplant were higher in the Humidification Group compared to the Control Group (p < 0.0001). There were no significant differences in the ETCO 2 , PaCO 2 , minute ventilation, or inotropic support. The humidified high flow CO 2 warming system was superior to standardized multimodal strategies in maintaining normothermia in patients undergoing OLT. Use of the device was feasible and did not interfere with any aspects of surgery. A larger study is needed to investigate if the improved thermoregulation observed is associated with improved patient outcomes. ACTRN12616001631493 . Retrospectively registered 25 November 2016.

  10. Development and evaluation of a training module for the clinical introduction of the da Vinci robotic system in visceral and vascular surgery.

    Science.gov (United States)

    Mehrabi, A; Yetimoglu, C L; Nickkholgh, A; Kashfi, A; Kienle, P; Konstantinides, L; Ahmadi, M R; Fonouni, H; Schemmer, P; Friess, H; Gebhard, M M; Büchler, M W; Schmidt, J; Gutt, C N

    2006-09-01

    With the increasing use of the surgical robotic system in the clinical arena, appropriate training programs and assessment systems need to be established for mastery of this new technology. The authors aimed to design and evaluate a clinic-like training program for the clinical introduction of the da Vinci robotic system in visceral and vascular surgery. Four trainees with different surgical levels of experience participated in this study using the da Vinci telemanipulator. Each participant started with an initial evaluation stage composed of standardized visceral and vascular operations (cholecystectomy, gastrotomy, anastomosis of the small intestine, and anastomosis of the aorta) in a porcine model. Then the participants went on to the training stage with the rat model, performing standardized visceral and vascular operations (gastrotomy, anastomosis of the large and small intestines, and anastomosis of the aorta) four times in four rats. The final evaluation stage was again identical to the initial stage. The operative times, the number of complications, and the performance quality of the participants were compared between the two evaluation stages to assess the impact of the training stage on the results. The operative times in the final evaluation stage were considerably shorter than in the initial evaluation stage and, except for cholecystectomies, all the differences reached statistical significance. Also, significantly fewer complications and improved quality for each operation in the final evaluation stage were documented, as compared with their counterparts in the initial evaluation stage. These improvements were recorded at each level of experience. The presented experimental small and large animal model is a standardized and reproducible training method for robotic surgery that allows evaluation of the surgical performance while shortening and optimizing the learning-curve.

  11. Robotic Applications in Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Alan P. Kypson

    2008-11-01

    Full Text Available Traditionally, cardiac surgery has been performed through a median sternotomy, which allows the surgeon generous access to the heart and surrounding great vessels. As a paradigm shift in the size and location of incisions occurs in cardiac surgery, new methods have been developed to allow the surgeon the same amount of dexterity and accessibility to the heart in confined spaces and in a less invasive manner. Initially, long instruments without pivot points were used, however, more recent robotic telemanipulation systems have been applied that allow for improved dexterity, enabling the surgeon to perform cardiac surgery from a distance not previously possible. In this rapidly evolving field, we review the recent history and clinical results of using robotics in cardiac surgery.

  12. Robotics in reproductive surgery: strengths and limitations.

    Science.gov (United States)

    Catenacci, M; Flyckt, R L; Falcone, T

    2011-09-01

    Minimally invasive surgical techniques are becoming increasingly common in gynecologic surgery. However, traditional laparoscopy can be challenging. A robotic surgical system gives several advantages over traditional laparoscopy and has been incorporated into reproductive gynecological surgeries. The objective of this article is to review recent publications on robotically-assisted laparoscopy for reproductive surgery. Recent clinical research supports robotic surgery as resulting in less post-operative pain, shorter hospital stays, faster return to normal activities, and decreased blood loss. Reproductive outcomes appear similar to alternative approaches. Drawbacks of robotic surgery include longer operating room times, the need for specialized training, and increased cost. Larger prospective studies comparing robotic approaches with laparoscopy and conventional open surgery have been initiated and information regarding long-term outcomes after robotic surgery will be important in determining the ultimate utility of these procedures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Cost-Benefit Performance Simulation of Robot-Assisted Thoracic Surgery As Required for Financial Viability under the 2016 Revised Reimbursement Paradigm of the Japanese National Health Insurance System.

    Science.gov (United States)

    Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-04-20

    To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.

  14. Robotic Surgery

    Science.gov (United States)

    Childress, Vincent W.

    2007-01-01

    The medical field has many uses for automated and remote-controlled technology. For example, if a tissue sample is only handled in the laboratory by a robotic handling system, then it will never come into contact with a human. Such a system not only helps to automate the medical testing process, but it also helps to reduce the chances of…

  15. Combining Systems and Teamwork Approaches to Enhance the Effectiveness of Safety Improvement Interventions in Surgery: The Safer Delivery of Surgical Services (S3) Program.

    Science.gov (United States)

    McCulloch, Peter; Morgan, Lauren; New, Steve; Catchpole, Ken; Roberston, Eleanor; Hadi, Mohammed; Pickering, Sharon; Collins, Gary; Griffin, Damian

    2017-01-01

    Patient safety improvement interventions usually address either work systems or team culture. We do not know which is more effective, or whether combining approaches is beneficial. To compare improvement in surgical team performance after interventions addressing teamwork culture, work systems, or both. Suite of 5 identical controlled before-after intervention studies, with preplanned analysis of pooled data for indirect comparisons of strategies. Operating theatres in 5 UK hospitals performing elective orthopedic, plastic, or vascular surgery PARTICIPANTS:: All operating theatres staff, including surgeons, nurses, anaesthetists, and others INTERVENTIONS:: 4-month safety improvement interventions, using teamwork training (TT), systems redesign and standardization (SOP), Lean quality improvement, SOP + TT combination, or Lean + TT combination. Team technical and nontechnical performance and World Health Organization (WHO) checklist compliance, measured for 3 months before and after intervention using validated scales. Pooled data analysis of before-after change in active and control groups, comparing combined versus single and systems versus teamwork interventions, using 2-way ANOVA. We studied 453 operations, (255 intervention, 198 control). TT improved nontechnical skills and WHO compliance (P teamwork training and systems rationalization are more effective than those adopting either approach alone. This has important implications for safety improvement strategies in hospitals.

  16. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ...

  17. TRAUMA SURGERY

    African Journals Online (AJOL)

    interest in developing an appropriate and sustainable trauma system in South ... trauma evolved with the social instability which accompanied political change in the ... increased use of military style assault weapons resulted in severe injuries ...

  18. [Thromboelastography and its use in cardiac surgery].

    Science.gov (United States)

    Ak, Koray; Atalan, Nazan; Tekeli, Atike; Işbir, Selim; Civelek, Ali; Emekli, Nesrin; Arsan, Sinan

    2008-04-01

    Thromboelastography is an alternative method to conventional coagulation tests for the general evaluation of hemostatic system. Cardiac surgery with cardiopulmonary bypass is accomplished by complex alterations of hemostasis, including acquired dysfunction of platelets, consumption coagulopathy and increased fibrinolysis. Despite major advances in blood conservation methods and perioperative care of the patients, transfusion rates in cardiac surgery remain high. Thromboelastography has an ability to assess almost all components of haemostatic system globally. Currently, thromboelastography is used with standard coagulation tests to decrease the microvascular bleeding and homologous blood transfusion in cardiac surgery with cardiopulmonary bypass. In this review, we aimed to discuss thromboelastography technology and its usage in cardiac surgery.

  19. SURGERY AND CARDIOVASCULAR SURGERY JOURNALS ANALYSIS.

    Science.gov (United States)

    Schanaider, Alberto

    2015-01-01

    To analyze critically the effectiveness and value of bibliometric indicators in journals of Surgery or Cardiovacular Surgery in the context of the postgraduate programs of CAPES Medicine III. A sampling with 16 academic programs and one professional master of Medicine III, encompassing the General and Digestive System Surgery, Cardiovascular Surgery and Multidisciplinary courses with such contents, was evaluated. Thomson Reuters/ISI (JCR), Elsevier/Scopus (SJR), and also Scielo databases were used. Only in seven programs, the teachers had an average of Qualis A1 articles greater than the others strata. Eleven journals in the surgical area are in stratum A1 (5%) and it reaches 25% in Cardiovascular Surgery. Among the six journals with the largest number of publications Qualis A1 in area Medicine III, five are from non-specific areas. The Acta Cirúrgica Brasileira represented 58% of the publications in the stratum A2. There are some obstacles in the Qualis classification with little uniformity among the Medicine areas I, II and III. A permanent committee should be set to update the Qualis, composed by the three medical areas. It should be considered using other index databases and the unification of the Qualis criteria for journals in medicine. Rating criteria of multi and transdisciplinary journals need to be reviewed. It is essential an institutional financial support for national journals chosen by peers aiming to provide a full computerization process and a professional reviewer of the English language, in order to increase the impact factor. Analisar criticamente a eficácia e valor de indicadores bibliométricos dos periódicos da Cirurgia e Cirurgia Cardiovascular no contexto dos Programas de Pós-Graduação da área Medicina III da CAPES. Foi avaliada uma amostragem com 16 programas acadêmicos e um mestrado profissional da área de Medicina III, compreendendo a Cirurgia Geral e do Aparelho Digestivo, a Cirurgia Cardiovascular e Cursos Multidisciplinares

  20. Surgery applications of virtual reality

    Science.gov (United States)

    Rosen, Joseph

    1994-01-01

    Virtual reality is a computer-generated technology which allows information to be displayed in a simulated, bus lifelike, environment. In this simulated 'world', users can move and interact as if they were actually a part of that world. This new technology will be useful in many different fields, including the field of surgery. Virtual reality systems can be used to teach surgical anatomy, diagnose surgical problems, plan operations, simulate and perform surgical procedures (telesurgery), and predict the outcomes of surgery. The authors of this paper describe the basic components of a virtual reality surgical system. These components include: the virtual world, the virtual tools, the anatomical model, the software platform, the host computer, the interface, and the head-coupled display. In the chapter they also review the progress towards using virtual reality for surgical training, planning, telesurgery, and predicting outcomes. Finally, the authors present a training system being developed for the practice of new procedures in abdominal surgery.

  1. Comparison of acoustic shock waves generated by micro and nanosecond lasers for a smart laser surgery system

    Science.gov (United States)

    Nguendon Kenhagho, Hervé K.; Rauter, Georg; Guzman, Raphael; C. Cattin, Philippe; Zam, Azhar

    2018-02-01

    Characterization of acoustic shock wave will guarantee efficient tissue differentiation as feedback to reduce the probability of undesirable damaging (i.e. cutting) of tissues in laser surgery applications. We ablated hard (bone) and soft (muscle) tissues using a nanosecond pulsed Nd:YAG laser at 532 nm and a microsecond pulsed Er:YAG laser at 2.94 μm. When the intense short ns-pulsed laser is applied to material, the energy gain causes locally a plasma at the ablated spot that expands and propagates as an acoustic shock wave with a rarefaction wave behind the shock front. However, when using a μs-pulsed Er:YAG laser for material ablation, the acoustic shock wave is generated during the explosion of the ablated material. We measured and compared the emitted acoustic shock wave generated by a ns-pulsed Nd:YAG laser and a μs-pulsed Er:YAG laser measured by a calibrated microphone. As the acoustic shock wave attenuates as it propagates through air, the distance between ablation spots and a calibrated microphone was at 5 cm. We present the measurements on the propagation characteristics of the laser generated acoustic shock wave by measuring the arrival time-of-flight with a calibrated microphone and the energy-dependent evolution of acoustic parameters such as peak-topeak pressure, the ratio of the peak-to-peak pressures for the laser induced breakdown in air, the ablated muscle and the bone, and the spectral energy.

  2. Apparatus for stereotactic surgery

    International Nuclear Information System (INIS)

    Koslow, M.A.M.

    1982-01-01

    Apparatus for stereotactic surgery consisting of a probe and a computerized tomographic scanning system is described. The scanning system comprises a display and means for reconstructing cross-sectional images on the display using data from partial circumferential scans of source and detectors. It operates on the data with an algorithm that provides the difference between the local values of the linear attenuation coefficient and average of these values within a circle centered at each reconstruction point. The scanning system includes a means of maintaining the frames of reference of the probe and scanning system rigid with respect to one another. The position of the probe, which may be a cryogenic probe, with respect to the actual anatomical structure of the body, particularly a human head, may thus be viewed by the surgeon. (author)

  3. Major morbidity after video-assisted thoracic surgery lung resections: a comparison between the European Society of Thoracic Surgeons definition and the Thoracic Morbidity and Mortality system.

    Science.gov (United States)

    Sandri, Alberto; Papagiannopoulos, Kostas; Milton, Richard; Kefaloyannis, Emmanuel; Chaudhuri, Nilanjan; Poyser, Emily; Spencer, Nicholas; Brunelli, Alessandro

    2015-07-01

    The thoracic morbidity and mortality (TM&M) classification system univocally encodes the postoperative adverse events by their management complexity. This study aims to compare the distribution of the severity of complications according to the TM&M system versus the distribution according to the classification proposed by European Society of Thoracic Surgeons (ESTS) Database in a population of patients submitted to video assisted thoracoscopic surgery (VATS) lung resection. A total of 227 consecutive patients submitted to VATS lobectomy for lung cancer were analyzed. Any complication developed postoperatively was graded from I to V according to the TM&M system, reflecting the increasing severity of its management. We verified the distribution of the different grades of complications and analyzed their frequency among those defined as "major cardiopulmonary complications" by the ESTS Database. Following the ESTS definitions, 20 were the major cardiopulmonary complications [atrial fibrillation (AF): 10, 50%; adult respiratory distress syndrome (ARDS): 1, 5%; pulmonary embolism: 2, 10%; mechanical ventilation >24 h: 1, 5%; pneumonia: 3, 15%; myocardial infarct: 1, 5%; atelectasis requiring bronchoscopy: 2, 10%] of which 9 (45%) were reclassified as minor complications (grade II) by the TM&M classification system. According to the TM&M system, 10/34 (29.4%) of all complications were considered minor (grade I or II) while 21/34 (71.4%) as major (IIIa: 8, 23.5%; IIIb: 4, 11.7%; IVa: 8, 23.5%; IVb: 1, 2.9%; V: 3, 8.8%). Other 14 surgical complications occurred and were classified as major complications according to the TM&M system. The distribution of postoperative complications differs between the two classification systems. The TM&M grading system questions the traditional classification of major complications following VATS lung resection and may be used as an additional endpoint for outcome analyses.

  4. Ranking sources of hospital quality information for orthopedic surgery patients: consequences for the system of managed competition.

    NARCIS (Netherlands)

    Bes, R.E.; Berg, B. van den

    2013-01-01

    Background: Healthcare quality information is crucial for the system of managed competition. Within a system of managed competition, health insurers can selectively contract care providers and are allowed to channel patients towards contracted providers. The idea is that insurers have a stronger

  5. GENERAL SURGERY

    African Journals Online (AJOL)

    2017-11-04

    Nov 4, 2017 ... One of the principles integrated into the South African state healthcare system is the ... care. Similarly, the types and severity of surgical conditions which should be ... Emergency admissions constituted 62.4% and elective admissions ... development of information technology (IT) has allowed the creation of ...

  6. GENERAL SURGERY

    African Journals Online (AJOL)

    programme based in university hospitals.6,7 A paucity of literature focuses specifically on the career paths of IMGs currently serving in the South African healthcare system. The objective of this study was to review the demographic profiles and career intentions of IMGs currently working in a university hospital, in the hope of ...

  7. Pre-operative evaluation for thorax surgery

    International Nuclear Information System (INIS)

    Silva Luis, Saenz; Morales, Oscar Alberto

    2002-01-01

    A pre-operative analysis of the function of the breathing system is made in the patient that will be taken to thorax surgery. The paper includes risk factors, pre-operative clinical evaluation and of breathing and cardiovascular system