  1. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  2. Radio-controlled automatic gas meter-reading system; Releve automatique de compteur par radio

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, M. [Osaka Gas Co., Ltd (Japan); Ishikawa, K.; Fujiwara, J. [Tokyo Gas Co., Ltd. (Japan); Ichihashi, T. [Toho Gas Co., Ltd. (Japan)

    2000-07-01

    In Japan, an automatic gas meter-reading system is in operation, also incorporating the functions of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff. This system has been realized by linking microcomputer-controlled gas meters(It's called 'Intelligent gas mater') equipped with automatic shutoff mechanism to the gas utility company operation center via communication lines. While the present system uses cable communication lines, we of Tokyo Gas Co., Ltd., Osaka Gas Co., Ltd. and Toho Gas Co., Ltd., have jointly developed a new system based on radio communication. This paper introduces this new system. While radio-controlled meter-reading systems are used in many countries around the world solely for automatic meter reading, our recently developed system is also capable of monitoring for abnormalities in gas use and remote-controlled emergency gas supply shutoff, thanks to its almost real-time two-way communication function. The new system can serve for a period of ten years without recharging. It is also characterized by its applicability as different systems according to purposes: 1) conventional automatic meter-reading system (terminal network control unit or T-NCU), 2) large-scale radio-controlled meter-reading system, and 3) portable terminal-type radio-controlled meter-reading system. (authors)

  3. Radiography of Spanish Radio

    Directory of Open Access Journals (Sweden)

    Dra. Emma Rodero Antón

    2007-01-01

    Full Text Available In its eighty years of existence, radio has been always characterized to adapt to the social, cultural and technological transformations. Thus it has been until this moment. Nevertheless, some years ago, the authors and professionals of this medium have been detecting a stagnation that affects to its structure. At a time in continuous technological evolution, radio demands a deep transformation. For that reason, from the conviction of which the future radio, public and commercial, will necessarily have to renew itself, in this paper we establish ten problems and their possible solutions to the radio crisis in order to draw an x-ray of radio in Spain. Radio has future, but it is necessary to work actively by it. That the radio continues being part of sound of our life, it will depend on the work of all: companies, advertisers, professionals, students, investigators and listeners.

  4. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  5. Performance evaluation of a 'dual-side read' dedicated mammography computed radiography system

    International Nuclear Information System (INIS)

    Fetterly, Kenneth A.; Schueler, Beth A.

    2003-01-01

    The image quality of a dedicated mammography computed radiography (CR) system was characterized. A unique feature of this system is that it collects image signals from both sides of the storage phosphor. Measurements of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were made. This work included improvements in our measurement methods to specifically account for the detrimental effects of system glare on the MTF and to accurately characterize the low-frequency NPS components. Image quality measurements were performed using a 25 kVp beam filtered with 2 mm Al and an exposure range of 1 to 100 mR (87 to 870 μGy). The DQE was found to decrease with increasing exposure due to an increased contribution of storage phosphor structure noise. The DQE of this system was compared to similar measurements made using a standard CR system. The dual-side read system demonstrated superior DQE compared to the standard system. The decrease in DQE with increasing exposure was more severe for the standard system than the dual-side read system. This finding suggests that the CR system noise was reduced for the dual-side read system compared to the standard system

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  7. An evaluation of automated chest radiography reading software for tuberculosis screening among public- and private-sector patients

    OpenAIRE

    Rahman, Md Toufiq; Codlin, Andrew J.; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera; Creswell, Jacob

    2017-01-01

    Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert). Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receive...

  8. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  9. Radiation exposure during equine radiography

    International Nuclear Information System (INIS)

    Ackerman, N.; Spencer, C.P.; Hager, D.A.; Poulos, P.W. Jr.

    1988-01-01

    All personnel present in the X-ray examination room during equine radiography were monitored using low energy direct reading ionization chambers (pockets dosimeters) worn outside the lead apron at neck level. The individuals' task and dosimeter readings were recorded after each examination. Average doses ranged from 0 to 6 mrad per study. The greatest exposures were associated with radiography of the shoulder and averaged less than 4 mrad. The individual extending the horse's limb was at greatest risk although the individual holding the horse's halter and the one making the X-ray exposure received similar exposures. A survey of the overhead tube assembly used for some of the X-ray examinations also was performed. Meter readings obtained indicated an asymetric dose distribution around the tube assembly, with the highest dose occurring on the side to which the exposure cord was attached. Although the exposures observed were within acceptable limits for occupational workers, we have altered our protocol and no longer radiograph the equine shoulder unless the horse is anesthetized. Continued use of the pocket dosimeters and maintenance of a case record of radiation exposure appears to make the technologists more aware of radiation hazards

  10. Finding-specific display presets for computed radiography soft-copy reading.

    Science.gov (United States)

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  11. Satisfaction of Search in Chest Radiography 2015.

    Science.gov (United States)

    Berbaum, Kevin S; Krupinski, Elizabeth A; Schartz, Kevin M; Caldwell, Robert T; Madsen, Mark T; Hur, Seung; Laroia, Archana T; Thompson, Brad H; Mullan, Brian F; Franken, Edmund A

    2015-11-01

    Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P chest radiography (P chest radiography has changed, but it is not clear why. SOS may be changing as a function of changes in radiology education and practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  12. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  13. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  14. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  15. Wireless radio a history

    CERN Document Server

    Coe, Lewis

    2006-01-01

    ""Informative...recommended""--Choice; ""interesting...a good read...well worth reading""--Contact Magazine. This history first looks at Marconi's wireless communications system and then explores its many applications, including marine radio, cellular telephones, police and military uses, television and radar. Radio collecting is also discussed, and brief biographies are provided for the major figures in the development and use of the wireless.

  16. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  17. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  18. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  19. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  20. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  1. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  2. A study of quantitative radiography for moisture content distributions in plant

    International Nuclear Information System (INIS)

    Kawabata, Y.; Hino, M.; Horie, T.

    2003-01-01

    Vacuum pre-cooling in cut flower or perishable vegetables industry are used for protecting from the deterioration of the perishables during transportation. Some improvements of the pre-cooling way, however, are required for a bruise in plant on the way of handling. Neutron radiography is suitable to detect and observe the bruise in plant, especially, moisture content distributions in leaves, flowers and stalks. Neutron spectrum in irradiation neutron beams is required for obtaining quantitative moisture contents in plant. The neutron spectrum measurements for determination of effective cross-section of water are carried out at CN-3 experimental hole of Kyoto University Reactor (KUR) by time of flight method. Moisture content distributions in leaves of chrysanthemum, before and after the vacuum pre-cooling are measured by cold neutron radiography at the experimental hole. The local decreases of moisture contents caused by a bruise on the surface of the leaves are measured quantitatively by the cold neutron radiography. The quantitative changes of the moisture content in the leaves are able to read out from the cold neutron radiography image. (M. Suetake)

  3. Radio-analysis. Definitions and techniques

    International Nuclear Information System (INIS)

    Bourrel, F.; Courriere, Ph.

    2003-01-01

    This paper presents the different steps of the radio-labelling of a molecule for two purposes: the radio-immuno-analysis and the auto-radiography: 1 - definitions, radiations and radioprotection: activity of a radioactive source; half-life; radioactivity (alpha-, beta- and gamma radioactivity, internal conversion); radioprotection (irradiation, contamination); 2 - radionuclides used in medical biology and obtention of labelled molecules: gamma emitters ( 125 I, 57 Co); beta emitters; obtention of labelled molecules (general principles, high specific activity and choice of the tracer, molecule to be labelled); main labelling techniques (iodation, tritium); purification of the labelled compound (dialysis, gel-filtering or molecular exclusion chromatography, high performance liquid chromatography); quality estimation of the labelled compound (labelling efficiency calculation, immuno-reactivity conservation, stability and preservation). (J.S.)

  4. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  5. The MU-RAY detector for muon radiography of volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Anastasio, A. [INFN-Napoli (Italy); Ambrosino, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Basta, D. [INFN-Napoli (Italy); Bonechi, L. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); Brianzi, M. [Università degli Studi di Firenze, Firenze (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Caputo, A. [INGV Osservatorio Vesuviano, Napoli (Italy); Ciaranfi, R. [INFN-Firenze (Italy); Cimmino, L. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); D' Alessandro, R. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); D' Auria, L. [INGV Osservatorio Vesuviano, Napoli (Italy); La Taille, C. de [LAL, Orsay (France); Energico, S. [CNR- SPIN, Napoli (Italy); INFN-Napoli (Italy); Garufi, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Giudicepietro, F. [INGV Osservatorio Vesuviano, Napoli (Italy); Lauria, A. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Macedonio, G.; Martini, M. [INGV Osservatorio Vesuviano, Napoli (Italy); Masone, V. [Università Federico II, Napoli (Italy); and others

    2013-12-21

    The MU-RAY detector has been designed to perform muon radiography of volcanoes. The possible use on the field introduces several constraints. First the electric power consumption must be reduced to the minimum, so that the detector can be solar-powered. Moreover it must be robust and transportable, for what concerns the front-end electronics and data acquisition. A 1 m{sup 2} prototype has been constructed and is taking data at Mt. Vesuvius. The detector consists of modules of 32 scintillator bars with wave length shifting fibers and silicon photomultiplier read-out. A dedicated front-end electronics has been developed, based on the SPIROC ASIC. An introduction to muon radiography principles, the MU-RAY detector description and results obtained in laboratory will be presented.

  6. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  7. Radiography – How do students understand the concept of radiography?

    International Nuclear Information System (INIS)

    Lundgren, S.M.; Lundén, M.; Andersson, B.T.

    2015-01-01

    Background: Radiography as a concept has mainly been associated with the functional role of the radiographer. The concept has been studied from a theoretical point of view. However, there is a lack of a theoretical foundation and research on the actual substance of the term radiography used in education. It is therefore important to undertake an investigation in order to determine how students after three years education understand the subject of radiography. Aim: The aim of this study was to analyse how students in the Swedish radiographers' degree program understand the concept of radiography. Method: A concept analysis was made according to the hybrid model, which combines theoretical, fieldwork and analytical phases. A summative content analysis was used to identify the number and content of statements. The empirical data were collected from questionnaires answered by radiography students at four universities in Sweden. Findings: All radiography students' exemplified radiography with statements related to the practical level although some of them also identified radiography at an abstract level, as a subject within a discipline. The attribute ‘An interdisciplinary area of knowledge’ emerged, which is an attribute on the abstract level. The practical level was described by four attributes: Mastering Medical Imaging’, ‘To accomplish images for diagnosis and interventions’, ‘Creating a caring environment’ and ‘Enabling fruitful encounters’. Conclusion: The hybrid model used was a versatile model of concept development. The results of this study have increased the understanding of what characterizes the concept of radiography in a Swedish context. - Highlights: • This concept analysis of radiography was undertaken according to a hybrid model. • In radiography humanistic aspects are emphasized, a shift from the technological perspective. • The attributes demonstrate the essence and interdisciplinary nature of radiography. • This

  8. Digital radiography: description and user's guide

    International Nuclear Information System (INIS)

    Berthel, A.; Bonin, Th.; Cadilhon, S.; Thiery, Ch.; Chatellier, L.; Kaftandjian, V.; Honorat, Ph.; Torrent, J.; Le Brun, A.; Maglaive, J.C.; Moreau, Ph.; Pettier, J.L.; Rebuffel, V.; Roenelle, P.; Roussilhe, J.; Staat, St.; Tahon, M.

    2007-01-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  9. Digital radiography of the chest in pediatric patients

    International Nuclear Information System (INIS)

    Puig, S.

    2003-01-01

    The hopes placed in digital radiography have been fulfilled only partly in pediatric radiology. Specifically, the option of gaining reduced radiation exposure in combination with a similar or even improved image quality was hard to realize. The only portable digital system available for a long time were storage phosphors which were disadvantaged by an extremely limited dose-quantum-efficiency (DQE) in comparison to digital flat panel detectors. New developments and the introduction of the dual-reading system led to image qualities comparable to film-screen-systems with high resolution and achievable without dose increase, sometimes even with dose reduction. A study using an animal model suggests that these systems can even be used in preterm infants with very low birth weights. A new portable flat panel detector by Canon may improve digital chest radiography in pediatric patients. (orig.) [de

  10. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  11. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  12. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    Energy Technology Data Exchange (ETDEWEB)

    Cowlam, S. [Sunderland Royal Hospital, Sunderland (United Kingdom); Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I. [University Hospital of North Durham, Durham (United Kingdom); Yiannakou, Y.J. [University Hospital of North Durham, Durham (United Kingdom)], E-mail: yan.yiannakou@cddft.nhs.uk

    2008-12-15

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically.

  13. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    International Nuclear Information System (INIS)

    Cowlam, S.; Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I.; Yiannakou, Y.J.

    2008-01-01

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically

  14. Filmless Radiography

    Science.gov (United States)

    1997-01-01

    Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

  15. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  16. Metaphyseal bone loss demonstrated with routine planar radiography

    International Nuclear Information System (INIS)

    Mintzer, C.M.; Robertson, D.D.; Weissman, B.; Ewald, F.; Spector, M.

    1989-01-01

    This paper reports on an vitro study performed to examine the ability of current-day radiography for detecting metaphyseal bone loss. A block was cut from the anterior aspect of a cadaveric distal femur, sequential sections (approximately 4% of the BMC of the block) were cut from the block, and a fat-equivalent material was substituted in to the void. Following removal of each bone section, the femur was placed in a water bath, a lateral radiography was taken, and the ash content of the section was determined. Five readers each evaluated over 100 combinations of two radiographs side by side, noting whether there was no difference or whether one femur's region of interest was denser. The readings were compared with bone mineral differences as determined by ashing. All readers identified losses of 25% or more, and 5%-10% losses were seen by four of five readers half of the time

  17. Plain abdominal radiography: A powerful tool to prognosticate outcome in patients with zinc phosphide poisoning

    International Nuclear Information System (INIS)

    Hassanian-Moghaddam, H.; Shahnazi, Makhtoom; Zamani, N.; Rahimi, M.; Bahrami-Motlagh, H.; Amiri, H.

    2014-01-01

    Aim: To evaluate the clinical features of zinc phosphide poisoning and to investigate whether outcome could be prognosticated based on abdominal radiography on presentation. Materials and methods: All zinc phosphide-poisoned patients who were referred to Loghman-Hakim Hospital between March 2011 and September 2013 were retrospectively reviewed. Data regarding patients' demographic characteristics, characteristics of the poisoning, abdominal radiography results, and patients' outcome were recorded. Results: In 102 patients, the most common presenting signs/symptoms were nausea and vomiting (60%). Four patients died and another seven had developed complications during their hospitalization (metabolic acidosis, liver abnormalities, or acute renal failure). Nineteen patients had radio-opaque abdominal radiographs, nine of whom had died or developed complications (p = 0.001). Plain abdominal radiography had a sensitivity and specificity of 81% and 89% in predicting the patients' death or further development of complications. The positive and negative predictive values were 47% and 97%, respectively. Conclusion: Plain abdominal radiography is a very good tool for prognostication in patients with zinc phosphide poisoning. Immediate abdominal radiography can help stratify patients into high- or low-risk groups and determine treatment strategies. - Highlights: • ZP poisoning may cause severe symptoms or death although less frequent compared to ALP. • ZP-poisoned patients may deteriorate within the first 72 hours post-ingestion. • Abdominal radiography is a good tool to predict death/complications in these patients

  18. Evaluation of chest tomosynthesis for the detection of pulmonary nodules: effect of clinical experience and comparison with chest radiography

    Science.gov (United States)

    Zachrisson, Sara; Vikgren, Jenny; Svalkvist, Angelica; Johnsson, Åse A.; Boijsen, Marianne; Flinck, Agneta; Månsson, Lars Gunnar; Kheddache, Susanne; Båth, Magnus

    2009-02-01

    Chest tomosynthesis refers to the technique of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest. In this study, a comparison of chest tomosynthesis and chest radiography in the detection of pulmonary nodules was performed and the effect of clinical experience of chest tomosynthesis was evaluated. Three senior thoracic radiologists, with more than ten years of experience of chest radiology and 6 months of clinical experience of chest tomosynthesis, acted as observers in a jackknife free-response receiver operating characteristics (JAFROC-1) study, performed on 42 patients with and 47 patients without pulmonary nodules examined with both chest tomosynthesis and chest radiography. MDCT was used as reference and the total number of nodules found using MDCT was 131. To investigate the effect of additional clinical experience of chest tomosynthesis, a second reading session of the tomosynthesis images was performed one year after the initial one. The JAFROC-1 figure of merit (FOM) was used as the principal measure of detectability. In comparison with chest radiography, chest tomosynthesis performed significantly better with regard to detectability. The observer-averaged JAFROC-1 FOM was 0.61 for tomosynthesis and 0.40 for radiography, giving a statistically significant difference between the techniques of 0.21 (p<0.0001). The observer-averaged JAFROC-1 FOM of the second reading of the tomosynthesis cases was not significantly higher than that of the first reading, indicating no improvement in detectability due to additional clinical experience of tomosynthesis.

  19. Wall Thickness Measurement Of Insulated Pipe By Tangential Radiography Technique Using Ir 192

    International Nuclear Information System (INIS)

    Soedarjo

    2000-01-01

    Insulation pipe wall thickness by tangential radiography technique has been carried out using 41 Curie Iridium 192 source has activity for two carbon steel pipes. The outer diameter of the first pipe is 90 mm, wall thickness is 75.0 mm, source film film distance is 609.5 mm, source tangential point of insulation is 489.5 mm and exposure time 3 minute and 25 second. From the calculation, the first pipe thickness is found to be 12.54 mm and for the second pipe is 8.42 mm. The thickness is due to inaccuracy in reading the pipe thickness on radiography film and the geometry distortion radiation path

  20. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  1. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.

  2. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  3. Application of X-ray radiography to archaeology

    International Nuclear Information System (INIS)

    Miura, Sadatoshi

    1994-01-01

    X-ray imaging techniques including radiography and scanning tomography are now often applied to archaeological and historical objects. In this report results of three imaging techniques are showed: radiography, X-ray scanning tomography and emissiography. X-ray radiography was applied to examine the technique used for a bronze object. The object was one of the national treasure from Horyuji-temple, Dragon-head Pitcher. The examination proved that the pitcher body was separated into three pieces and that the bronze was fairly homogeneous from 3 to 4 mm. The Pitcher was supposed to be made in Japan at the middle of the seventh century. A small gilt bronze statuette was investigated by an industrial X-ray scanner. The statuette about 30 cm high is supposed to be made in the seventh or eighth century. The head of the statuette was scanned by X-rays of 350kV. The computed tomograms revealed an inlaid metal and scraped hollow. It is supposed that the statuette was cast twice. The first casting might have failed causing the hollow and the missing part of the head. The hollow was scraped before the following casting so that the newly cast part would be tightly joined to the body. A piece of metal was inlaid to the missing part. A silver inlaid sword was excavated at a historic site called Etafunayama Kofun in Kumamoto in 1873. Seventy-five letters were discovered on the back of the sword, and they were regarded as important reference in studying Japanese history around the fifth century. However, the letters became illegible because of severe surface corrosion. So emissiography or electron radiography was used. All letters and even the details could be read. (author)

  4. Digital radiography: study of an alternative technique to conventional radiography

    International Nuclear Information System (INIS)

    Banchet, J.; Tisseur, D.; Thomas, A.

    2009-01-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  5. The MU-RAY project: Volcano radiography with cosmic-ray muons

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosi, G. [INFN sezione di Perugia (Italy); Ambrosino, F. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Battiston, R. [INFN sezione di Perugia (Italy); Universita di Perugia (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Cassese, F. [INFN sezione di Napoli (Italy); Castellini, G. [CNR-IFAC, Firenze (Italy); Ciaranfi, R. [INFN sezione Firenze (Italy); Cozzolino, F. [INFN sezione di Napoli (Italy); D' Alessandro, R. [INFN sezione Firenze (Italy); Universita di Firenze (Italy); La Taille, C. de [LAL, Orsay (France); Iacobucci, G. [INFN sezione di Napoli (Italy); Marotta, A. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Masone, V. [INFN sezione di Napoli (Italy); Martini, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Nishiyama, R. [Earthquake Research Institute, The University of Tokyo (Japan); Noli, P. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Orazi, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Parascandolo, L.; Parascandolo, P. [INFN sezione di Napoli (Italy)

    2011-02-01

    Cosmic-ray muon radiography is a technique for imaging the variation of density inside the top few 100 m of a volcanic cone. With resolutions up to 10s of meters in optimal detection conditions, muon radiography can provide images of the top region of a volcano edifice with a resolution that is considerably better than that typically achieved with conventional methods. Such precise measurements are expected to provide us with information on anomalies in the rock density distribution, like those expected from dense lava conduits, low density magma supply paths or the compression with depth of the overlying soil. The MU-RAY project aims at the construction of muon telescopes and the development of new analysis tools for muon radiography. The telescopes are required to be able to work in harsh environment and to have low power consumption, good angular and time resolutions, large active area and modularity. The telescope consists of two X-Y planes of 2x2 square meters area made by plastic scintillator strips of triangular shape. Each strip is read by a fast WLS fiber coupled to a silicon photomultiplier. The readout electronics is based on the SPIROC chip.

  6. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  7. Basic principles of industrial radiography

    International Nuclear Information System (INIS)

    Bestbier, P.

    1983-01-01

    X-ray radiography and gamma radiography are used in industrial radiography. X-rays and gamma rays have the ability to penetrate materials and be absorbed by different densities. This characteristic makes them useful tools in industrial and medical radiography. The sources used for the generation of x-rays, gamma rays and radioisotopes are discussed. Films are one of the recording methods of x-radiography. The article also deals with advantages and disadvantages of radiography. Factors governing radiation exposure includes: the type of radiation source, material to be radiographed, distance, film, and the method for development. International specifications are also responsible for strict control over the standard of workmanship in industrial radiography

  8. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M

    2016-01-01

    To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = radiography (P radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run.

  9. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  12. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  13. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  14. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  15. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  17. Digital radiography: description and user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Berthel, A. [Cryospace, 78 - Les Mureaux (France); Bonin, Th. [CEA Valduc, 21 - Is-sur-Tille (France); Cadilhon, S.; Thiery, Ch. [CEA Bruyeres-le-Chatel, 91 (France); Chatellier, L. [Electricite de France (EDF-RD), Recherche et Developpement, 78 - Chatou (France); Kaftandjian, V. [Lyon Univ., INSA Lab. Controle Non Destructif par Rayonnements Ionisants (CNDRI), 69 (France); Honorat, Ph.; Torrent, J. [SNECMA, 75 - Paris (France); Le Brun, A. [Electricite de France, 78 - Chatou (France); Maglaive, J.C. [Euromev, 78 - Buc (France); Moreau, Ph. [General Electric Industrial Inspection Technologies, 69 - Limonest (France); Pettier, J.L. [CEA Cadarach, Dir. de l' Energie Nucleaire, 13 - Saint Paul lez Durance (France); Rebuffel, V. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Roenelle, P. [Centre d' Etudes Techniques de l' Equipement, 69 - Bron Lyon (France); Roussilhe, J. [Carestream Health France SA, 71 - Chalon/Saone (France); Staat, St.; Tahon, M. [Cegelec, 91 - Bretigny sur Orge (France)

    2007-07-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  19. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    Science.gov (United States)

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  20. An evaluation of automated chest radiography reading software for tuberculosis screening among public- and private-sector patients.

    Science.gov (United States)

    Rahman, Md Toufiq; Codlin, Andrew J; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera; Creswell, Jacob

    2017-05-01

    Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert).Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receiver operating characteristic curve (AUC), and calculated the potential Xpert tests saved.A total of 18 036 individuals were enrolled. TB prevalence by Xpert was 15%. The radiologist graded 49% of CXRs as abnormal, resulting in 91% sensitivity and 58% specificity. At a similar sensitivity, CAR had a lower specificity (41%), saving fewer (36%) Xpert tests. The AUC for CAR was 0.74 (95% CI 0.73-0.75). CAR performance declined with increasing age. The radiologist grading was superior across all sub-analyses.Using CAR can save Xpert tests, but the radiologist's specificity was superior. Differentiated CAR thresholds may be required for different populations. Access to, and costs of, human readers must be considered when deciding to use CAR software. More studies are needed to evaluate CAR using different screening approaches. Copyright ©ERS 2017.

  1. Medical radiography examinations and carcinogenic effects

    International Nuclear Information System (INIS)

    Demina, Eh.A.

    2014-01-01

    The purpose of the review was the synthesis of the literature data and the results of our radiobiological (biodosimetric) research on the development of radiation-associated tumors as a result of medical radiography (X-ray) diagnostic. Medical X-ray examinations contribute the most to the excess of radiation exposure of the population, much of which is subject to examination to diagnose the underlying disease, the dynamic observation of the patient during treatment, the research of related diseases, and preventative examinations. The review provides arguments for the necessity of developing a more balanced indication for preventative radiological examination of the population in the aftermath of radio-ecological crisis caused by the Chornobyl accident, taking into account the likelihood of radiation carcinogenesis. The problems and tasks of biological (cytogenetic) dosimetry in radiology are formulated

  2. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  3. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  4. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  5. The “dirty chest”—correlations between chest radiography, multislice CT and tobacco burden

    Science.gov (United States)

    Kirchner, J; Goltz, J P; Lorenz, F; Obermann, A; Kirchner, E M; Kickuth, R

    2012-01-01

    Objectives Cigarette smoking-induced airway disease commonly results in an overall increase of non-specific lung markings on chest radiography. This has been described as “dirty chest”. As the morphological substrate of this condition is similar to the anthracosilicosis of coal workers, we hypothesised that it is possible to quantify the radiological changes using the International Labour Organization (ILO) classification of pneumoconiosis. The aims of this study were to evaluate whether there is a correlation between the extent of cigarette smoking and increased lung markings on chest radiography and to correlate the chest radiographic scores with findings on CT studies. Methods In a prospective analysis a cohort of 85 smokers was examined. The cigarette consumption was evaluated in pack years (defined as 20 cigarettes per day over 1 year). Film reading was performed by two board-certified radiologists. Chest radiographs were evaluated for the presence of thickening of bronchial walls, the presence of linear or nodular opacities, and emphysema. To correlate the smoking habits with the increase of overall lung markings in chest radiography, the ILO profusion score was converted to numbers ranging from zero to nine. Chest radiographs were rated according to the complete set of standard films of the revised ILO classification. Results 63/85 (74%) of the smokers showed an increase in overall lung markings on chest radiography; 32 (37%) had an ILO profusion score of chest radiography and the cigarette consumption quantified as pack years (r=0.68). The majority of the heavy smokers (>40 pack years) showed emphysema; there was no significant difference between the prevalence of emphysema as diagnosed by CT (62%) or chest radiography (71%) (pchest radiography. PMID:21937617

  6. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  7. Neutron radiography using neutron imaging plate

    International Nuclear Information System (INIS)

    Chankow, Nares; Wonglee, Sarinrat

    2008-01-01

    Full text: The aims of this research are to study properties of neutron imaging plate, to obtain a suitable condition for neutron radiography and to use the neutron imaging plate for testing of materials nondestructively. The experiments were carried out by using a neutron beam from the Thai Research Reactor TRR-1/M1 at a power of 1.2 MW. A BAS-ND 2040 FUJI neutron imaging plate and a MX125 Kodak X-ray film/Gadolinium neutron converter screen combination were tested for comparison. It was found that the photostimulated light (PSL) read out of the imaging plate was directly proportional to the exposure time. It was also found that radiography with neutron using the imaging plate was approximately 40 times faster than the conventional neutron radiography using x-ray film/Gd converter screen combination. The sensitivity of the imaging plate to gamma-rays was investigated by using gamma-rays from an 192 Ir and a 60 Co radiographic sources. The imaging plate was found to be 5-6 times less sensitive to gamma-rays than a FUJI BAS-MS 2040 gamma-ray imaging plate. Finally, some specimens were selected to be radiographed with neutrons using the imaging plate and the x-ray film/Gd converter screen combination in comparison to x-rays. Parts containing light elements could be clearly observed by the two neutron radiographic techniques. It could be concluded that the image quality from the neutron imaging plate was comparable to the conventional x-ray film/Gd converter screen combination but the exposure time could be approximately reduced by a factor of 40

  8. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition); Surete radiologique en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-05-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in Horizontal-Ellipsis shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  9. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  10. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  11. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  12. Evaluation of occupational exposure in intraoral radiography

    International Nuclear Information System (INIS)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C.; Tilly Junior, Joao G.

    2014-01-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  13. MASER: Measuring, Analysing, Simulating low frequency Radio Emissions.

    Science.gov (United States)

    Cecconi, B.; Le Sidaner, P.; Savalle, R.; Bonnin, X.; Zarka, P. M.; Louis, C.; Coffre, A.; Lamy, L.; Denis, L.; Griessmeier, J. M.; Faden, J.; Piker, C.; André, N.; Genot, V. N.; Erard, S.; King, T. A.; Mafi, J. N.; Sharlow, M.; Sky, J.; Demleitner, M.

    2017-12-01

    The MASER (Measuring, Analysing and Simulating Radio Emissions) project provides a comprehensive infrastructure dedicated to low frequency radio emissions (typically Radioastronomie de Nançay and the CDPP deep archive. These datasets include Cassini/RPWS, STEREO/Waves, WIND/Waves, Ulysses/URAP, ISEE3/SBH, Voyager/PRA, Nançay Decameter Array (Routine, NewRoutine, JunoN), RadioJove archive, swedish Viking mission, Interball/POLRAD... MASER also includes a Python software library for reading raw data.

  14. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography

    International Nuclear Information System (INIS)

    Kirchner, J.; Stueckle, C.A.; Schilling, E.M.; Peters, J.

    2001-01-01

    To determine the diagnostic impact of daily bedside chest radiography in comparison with digital luminescence technique (DLR; storage phosphor radiography) and conventional film screen radiography, a prospective randomized study was completed in 210 mechanically ventilated patients with a total of 420 analysed radiographs. The patients were allocated to two groups: 150 patients underwent DLR, and 60 patients underwent conventional film screen radiography. Radiological analysis was performed consensually and therapeutic efficacy was assessed by the clinicians. There was no statistical significant difference between the frequency of abnormal findings seen on DLR and conventional film screen radiography. In total, 448 abnormal findings were present in 249 of 300 DLR and 97 of 120 conventional film screen radiographs. The most common findings were signs of overhydration (41 %), pleural effusion (31%), partial collapse of the lung (11%) and pneumothorax (2%). One hundred and twenty-three of 448 (27%) of these abnormal findings were thought to have a considerable impact on patient management. The high rate of abnormal findings with significant impact on patient management suggests that the use of daily bedside chest radiography may be reasonable. Copyright (2001) Blackwell Science Pty Ltd

  15. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  16. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  17. Computer radiography-X-ray with vision

    International Nuclear Information System (INIS)

    Waitiki, C.

    2006-01-01

    Computer radiography describes an entire process of creating a digital image including acquiring, processing, presenting and managing the image data. the cassettes are special in that they use an imaging plate instead of films. the imaging plate is coated with storage phosphors which captures x-ray as they pass through the patient. the imaging plate is read with a bar code reader and the imaging plate number recorded in the computer. The cassette is then loaded in the reader unit where it is read using infra-red light which excites the particles on the plate which in turn illuminates and picked by photo-sensors which converts the signal into digital pulses. the pulses then run through a board which converts it into an image which is then displayed on the control console. The plate then runs through the erasure section where it is exposed to yellow light, which erases the plate. The IP is then put back in the cassette and locked and can be reused for the next episode

  18. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  19. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  20. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  1. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  2. Dual-sided reading versus single-sided reading: comparison of image quality and radiation dose between the two computed radiography system

    International Nuclear Information System (INIS)

    Song Shaojuan; Qi Hengtao; Zhao Yongxia; Jiao Fanglian

    2007-01-01

    Objective: To assess and compare the difference in image quality and exposure dose between single-sided reading image plate (IP) and dual-sided reading IP. Methods: A contrast-detail phantom CDRAD 2.0 was exposed by single-sided and dual-sided reading IP with different mAs sets. The entrance surface doses were recorded for all images. Images were then presented to two radiologists on a high resolution monitor of diagnosis workstation. The image quality figure (IQF) was measured for each image. Statistical analysis was performed using Spearman's correlation test and Wilcoxon signed-rank test to compare the difference in image quality and exposure dose between single-sided IP and dual-sided reading IP. Results: With different tube current dosage of 5.6, 12.0, 20.0, 25.0, and 40.0 mAs, IQF values of single-sided reading IP were 47.95, 37.68, 34.31, 28.61, and 24.65, respectively, while those of dual- sided reading IP were 38.83, 29.81, 29.65, 25.16, and 21.43, respectively. The IQF difference between them showed statistical significance (P<0.05). Conclusion: Image quality of dual-sided reading IP has been proved to be far superior to that of single-sided reading IP, in particular for low contrast detail. The image quality of single-sided reading IP is similar to that of dual-sided reading IP only at high dose levels. The clinical application of dual-sided reading IP will reduce the exposure dose by about 25% compared with single-sided reading IP. (authors)

  3. Industrial Radiography Safety in Australia

    International Nuclear Information System (INIS)

    Hockings, Colin

    2006-01-01

    cumbersome and often exceeds the prescribed OH and S single person lifting limits. The role of industrial radiography has expanded to inspect not only welds and castings, so that it now includes inspection of assembled and processed goods ranging from automotive air-bags to canned food. It is also used in security systems at airports and other facilities. Almost all these applications use cabinet systems which are rarely the subject of serious radiation incidents or accidents. Gamma ray inspection no longer uses radium. The most common radio-isotopes in use now are Cobalt 60 and Iridium 192. Their freedom from the need for an electrical power supply; their high radiation energy and the ability to place a source in positions of limited physical access, ensures the ongoing attraction of the method. The useful activity ranges of typical sources vary according to their application and the effect on total inspection costs. Common source activities in Australia range between 185 and 370 GBq for Cobalt 60; and between 1500 and 3700 GBq for Iridium 192. Outside Australia however there are recent reports of routine industrial radiography using more than 5500 GBq of Iridium 192. Thus it can be appreciated that any radiation accidents involving these high activity sources have the potential for significant radiation doses. Personal Dose Data: ARPANSA and its predecessor, the Australian Radiation Laboratory, has been providing a personal radiation monitoring service for some time, and releases a summary report every few years (ARPANSA/TR 139, ARL/TR 121, ARL/TR 107). The selected data shown in Table 2 indicate a downward trend in occupational doses received by industrial radiographers working in open site situations, which are potentially the most hazardous. This trend is encouraging, especially when the number of industrial radiographers is increasing. A comparison of the ARPANSA data indicate that whilst the average Australian industrial radiographer's annual dose is higher than the

  4. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  5. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  6. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  7. Computed radiography versus mobile direct radiography for bedside chest radiographs: Impact of dose on image quality and reader agreement

    International Nuclear Information System (INIS)

    De Boo, D.W.; Weber, M.; Deurloo, E.E.; Streekstra, G.J.; Freling, N.J.; Dongelmans, D.A.; Schaefer-Prokop, C.M.

    2011-01-01

    Aim: To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Methods and materials: Three groups of age-, weight- and disease-matched ICU patients (n = 114 patients; 50 CXR per acquisition technique) underwent clinically indicated bedside CXR obtained with either CR (single read-out powder plates) or mobile DR (GOS-TFT detectors) at identical or 50% reduced dose (DR 50% ). Delineation of anatomic structures and devices used for patient monitoring, overall image quality and disease were scored by four readers. In 12 patients pairs of follow-up CR and DR images were available, and in 15 patients pairs of CR and DR 50% images were available. In these pairs the overall image quality was also compared side-by-side. Results: Delineation of anatomy in the mediastinum was scored better with DR or DR 50% than with CR. Devices used for patient monitoring were seen best with DR, with DR 50% being superior to CR. In the side-by-side comparison, the overall image quality of DR and DR 50% was rated better than CR in 96% (46/48) and 87% (52/60), respectively. Inter-observer agreement for the assessment of pathology was fair for CR and DR 50% (κ = 0.33 and κ = 0.39, respectively) and moderate for DR (κ = 0.48). Conclusion: Mobile DR units offer better image quality than CR for bedside chest radiography and allow for 50% dose reduction. Inter-observer agreement increases with image quality and is superior with DR, while DR 50% and CR are comparable.

  8. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  9. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  10. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  11. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  12. Simultaneous neutron radiography and infrared thermography measurement of boiling processes

    International Nuclear Information System (INIS)

    Murphy, J.H.; Glickstein, S.S.

    1997-01-01

    Boiling of water at 1 to 15 bar flowing upward within a narrow duct and a round test section was observed using both neutron radiography and infrared (IR) thermography. The IR readings of the test section outer wall temperatures show the effects of both fluid temperature and wall heat transfer coefficient variations, producing a difference between liquid and two phase regions. The IR images, in fact, appear very similar to the neutron images; both show clear indications of spatial and temporal variations in the internal fluid conditions during the boiling process

  13. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  14. LANL12-RS-107J PYTHON Radiography Analysis Tool (PyRAT). Mid-Year Deliverable Report for FY15

    International Nuclear Information System (INIS)

    Temple, Brian Allen; Armstrong, Jerawan Chudoung

    2015-01-01

    This document is a mid-year report on a deliverable for the PYTHON Radiography Analysis Tool (PyRAT) for project LANL12-RS-107J in FY15. The deliverable is deliverable number 2 in the work package and is titled ''Add the ability to read in more types of image file formats in PyRAT''. Right now PyRAT can only read in uncompressed TIF files (tiff files). It is planned to expand the file formats that can be read by PyRAT, making it easier to use in more situations. A summary of the file formats added include jpeg, jpg, png and formatted ASCII files.

  15. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  16. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  17. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  18. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  20. Case study: limitations of panoramic radiography in the anterior mandible.

    LENUS (Irish Health Repository)

    Walker, Cameron

    2009-12-01

    Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible. Clinical Relevance: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.

  1. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  2. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  3. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  4. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  5. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  6. Comparison of Radiography, Laser Fluorescence, and Visual Examination in Diagnosing Incipient OcclusalCaries of Permanent First Molars

    Directory of Open Access Journals (Sweden)

    Zahra Bahrololoomi

    2015-10-01

    Full Text Available Objectives: Early diagnosis of incipient and non cavitated carious lesions is crucial for performing preventive treatments. The aim of this study was to compare the effi- ciency of three diagnostic methods of bite-wing radiography, DIAGNOdent, and visu- al examination in diagnosing the incipient occlusal caries of permanent first molars.Materials and Methods:  In this diagnostic cross-sectional study, 109 premanent first molar teeth of 31 patients aged 7-13 years were examined visually by bite-wing radi- ograghy, and DIAGNOdent. Scoring of visual and radiography examinations were based on the Ekstrand classification. Visual examination after pit and fissure opening was used as the gold standard. ROC curve (Receiver Operating Characteristics was used to define the best cut-off point for DIAGNodent compareing with gold standard and inter-examiner reproductibility of visual, radiography were assessed using Kappa test and ICC (Intraclass Correlation wase used for DIAGNOdent values.Results: The sensitivity of detecting caries that had extended into the enamel was 81.4%, 86.3%, and 81.4% for visual examination, DIAGNOdent, and radiography, respectively. Moreover, the specificity was 100%, 71.4%, and 100% for visual obser- vation, DIAGNOdent, and radiography, respectively in the enamel. The Kappa index for inter-examiner correlation was 0.7 and 0.8 for visual examination and radiog- raphy, respectively. The ICC (Intraclass Correlation was 0.98 for the values read by DIAGNOdent.Conclusion: Visual examination is rendered as the first choice in the diagnosis of in- cipient caries. In suspicious cases, radiography and laser DIAGNOdent can be used as adjunct procedures.

  7. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  8. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  9. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  10. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  11. First experience with digital radiography

    International Nuclear Information System (INIS)

    Buchmann, F.

    1987-01-01

    The digital radiogram is explained, its advantages being the various possibilities of image processing, loss-free transmission, recording and storage capabilities, and in special cases, prompt availability of processed images. Digital subtraction angiography (DSA) and the high-resolution method of digital, luminescent radiography, which replaced the conventional film-foil radiography, are explained as the first developments for the introduction of digital radiography, which today already is an applicable technique. (orig./MG) [de

  12. Problems associated with digital luminescence radiography in the neonate and young infant. Problems with digital radiography.

    Science.gov (United States)

    Arthur, R J; Pease, J N

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted.

  13. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  14. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  15. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  16. Proton radiography using highpower femtosecond laser

    International Nuclear Information System (INIS)

    Choi, Chang Il

    2010-08-01

    A femtosecond laser emits pulses whose width is between few and few hundreds femtoseconds (10 -15 s). The production mechanism of the high energy protons generated by the femtosecond laser is not clear so far, but the technologies have been improving. The applications using the generated protons are the proton therapy, proton radiography, nuclear physics, security inspection, and so on. Especially in the radiography, the laser-generated protons are very useful to obtain high quality images of thin objects, because protons are able to penetrate an object following an almost straight path and give a depth distribution information of various elements in a subject. Since the laser-driven protons require lower cost and smaller facility than accelerator-based protons, the radiography using laser-driven protons have been of interest. In this research, we have performed the radiography experiments by using protons generated by the 100 TW titanium sapphire femtosecond laser facility of Advanced Photonics Research Institute (APRI) of Gwangju Institute of Science Technology (GIST). A CR-39 Solid State Nuclear Track Detector (SSNTD) has been used as radiography screen. The radiography digital images have been obtained by using an optical microscope and a CCD camera. Modulation Transfer Function (MTF) has been derived from analyzing the obtained images, and the spatial resolution of the images have been evaluated. And, we have performed the radiography experiments of monoenergetic proton from the Tandem Van de Graaff accelerator of Korea Institute of Geoscience and Mineral Resources (KIGAM). We have obtained and compared the radiography images from other proton production methods which are the laser and the accelerator, respectively. And also, we have found out the optimized chemical etching condition, in order to improve the spatial resolution of the radiography images. Finally, the evaluated maximum spatial resolution of the images are 2.09 μm

  17. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  18. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  19. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  20. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  1. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  2. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  3. Diagnostic utility of magnetic resonance imaging and radiography in juvenile spondyloarthritis: evaluation of the sacroiliac joints in controls and affected subjects.

    Science.gov (United States)

    Jaremko, Jacob L; Liu, Lei; Winn, Naomi J; Ellsworth, Janet E; Lambert, Robert G W

    2014-05-01

    To compare the utility of radiography and magnetic resonance imaging (MRI) for the diagnosis of juvenile-onset spondyloarthritis in pediatric patients presenting with low back and/or sacroiliac (SI) pain of potentially inflammatory etiology. Radiographs and MRI studies of the SI joints in 26 patients with juvenile spondyloarthritis (JSpA) and 35 controls were assessed independently by 2 radiologists, with discrepancies arbitrated by a third. Radiographs and MRI were blinded and read in separate batches in random order. Erosion was common and was the most useful diagnostic feature on radiography [positive likelihood ratio (LR) = 3.5] and was especially diagnostic of SpA on MRI (LR = 6.7). Subchondral sclerosis was common but was the least specific feature for both modalities. Joint space narrowing had some utility on radiography (LR = 2.0) and MRI (LR = 2.7) but was uncommon and had poor reader reliability. Bone marrow edema (LR = 3.1) and subarticular fat infiltration (LR = 4.5), detectable only on MRI, were both useful features. Global diagnostic impression of MRI (LR = 9.4) had very high utility for the diagnosis of JSpA, exceeding radiography (LR = 4.4) because of superior specificity. In addition, global diagnosis of SpA is much more reliably made on MRI (κ = 0.80) compared to radiography (κ = 0.30). Specificity and reliability of MRI of the SI joints are superior to radiography for the diagnosis of juvenile-onset SpA and, where available, MRI should replace radiography as the first line of investigation.

  4. New medical application: nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1977-01-01

    Nuclear scattering of 1 GeV protons is used to obtain three dimensional radiographies with a volume resolution of about 1 mm 3 . The information is different from the one given by X-ray radiographies and in particular one may get radiographies of the hydrogen included in objects. Results on a vertebral column and a 'sella turcica' are presented [fr

  5. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  6. Workshop on industrial isotope radiography: Programme and lectures

    International Nuclear Information System (INIS)

    1979-01-01

    The booklet contains the texts of lectures delivered in the Workshop on Industrial Radiography held at Bombay during 24-25 July 1979. The lectures cover some topics of relevance to industrial radiography. The topics are radiation protection and legislative aspects in industrial radiography; problems in field radiography in fertilizer industry, petrochemical industry and heavy engineering industry; occupational exposures in industrial radiography; and a review of the progress and recent trends in industrial radiographic techniques and equipment. (M.G.B.)

  7. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  8. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  9. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  10. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  11. An investigation into dental digital radiography in dental practices in West Kent following the introduction of the 2006 NHS General Dental Services contract.

    Science.gov (United States)

    Mauthe, Peter W; Eaton, Kenneth A

    2011-04-01

    The primary aims of the study were to investigate the use of digital radiography within primary dental care practices in the West Kent Primary Care Trust (PCT) area and general dental practitioners' (GDPs) self-reported change in radiographic prescribing patterns following the introduction of the nGDS contract in 2006. Data were gathered via a piloted, self-completed questionnaire, and circulated to all GDPs listed on the National Health Service (NHS) Choices website as practising in the West Kent PCT area. There were three mailings and follow-up telephone calls. The resulting data were entered into a statistical software database and, where relevant, statistically tested, using the chi-square test and Pearson correlation coefficient. Of 223 GDPs, 168 (75%) responded. There were 163 usable questionnaires. The respondents represented 85% of the general dental practices in West Kent. Eighty (49%) respondents were using digital intra-oral radiography. Of those who used digital radiography, 44 (55%) reported that they used phosphor plate systems and 36 (45%) that they used direct digital sensors. Eighty-three (51%) had a panoramic machine in their practice, 46 of whom (55%) were using digital systems; of these, 32 (67%) were using a direct digital system. Seventy-one GDPs reported that they worked exclusively or mainly in private practice. Forty (56%) of these 'mainly private' GDPs reported that they used digital radiographic systems, whereas only 40 (44%) of the 89 'mainly NHS' GDPs reported using digital radio-graphic systems. On average, mainly private GDPs made the transition to a digital radiographic system six months before mainly NHS GDPs. Of those who provided NHS dentistry before and after April 2006, only 18 (14%) reported taking fewer radiographs and seven (6%) taking more. In February 2010, of the West Kent GDPs who responded to the questionnaire, just under 50% used digital radio graphy. Mainly private GDPs were more likely to use digital radiography than

  12. Functioning of industrial radiography services

    International Nuclear Information System (INIS)

    Alves, R.N.; Costa, H.M. da; Bianchini, F.G.; Arrieta, L.A.I.

    1988-12-01

    The objective of this norm is establish the necessary requirements for the functioning of industrial radiography services, as well as the procedures for acquisition and transfer of radioactive sources and/or X-ray equipments used in industrial radiography [pt

  13. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  14. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  15. Industrial radiography techniques and their applications

    International Nuclear Information System (INIS)

    Wamorkar, R.R.

    1981-01-01

    Various aspects of industrial radiography are discussed. These include: radiation sources, geometrical unsharpness of image, radiation attenuation in the specimen, radiation effect of film, types of film, intensifying screens, exposure time calculations, source to film distance and sensivitity. Radiography techniques for examination of welded joints on flat plate and pipes or cylindrical objects, and castings are indicated. Applications of radiography in various industries are mentioned. (M.G.B.)

  16. Central axis dose verification in patients treated with total body irradiation of photons using a Computed Radiography system

    International Nuclear Information System (INIS)

    Rubio Rivero, A.; Caballero Pinelo, R.; Gonzalez Perez, Y.

    2015-01-01

    To propose and evaluate a method for the central axis dose verification in patients treated with total body irradiation (TBI) of photons using images obtained through a Computed Radiography (CR) system. It was used the Computed Radiography (Fuji) portal imaging cassette readings and correlate with measured of absorbed dose in water using 10 x 10 irradiation fields with ionization chamber in the 60 Co equipment. The analytical and graphic expression is obtained through software 'Origin8', the TBI patient portal verification images were processed using software ImageJ, to obtain the patient dose. To validate the results, the absorbed dose in RW3 models was measured with ionization chamber with different thickness, simulating TBI real conditions. Finally it was performed a retrospective study over the last 4 years obtaining the patients absorbed dose based on the reading in the image and comparing with the planned dose. The analytical equation obtained permits estimate the absorbed dose using image pixel value and the dose measured with ionization chamber and correlated with patient clinical records. Those results are compared with reported evidence obtaining a difference less than 02%, the 3 methods were compared and the results are within 10%. (Author)

  17. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  18. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  19. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  20. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  1. Musculoskeletal magnetic resonance imaging: importance of radiography

    International Nuclear Information System (INIS)

    Taljanovic, Mihra S.; Hunter, Tim B.; Fitzpatrick, Kimberly A.; Krupinski, Elizabeth A.; Pope, Thomas L.

    2003-01-01

    To determine the usefulness of radiography for interpretation of musculoskeletal (MSK) magnetic resonance imaging (MRI) studies. In a 1-year period, 1,030 MSK MRI studies were performed in 1,002 patients in our institution. For each study, the interpreting radiologist completed a questionnaire regarding the availability and utility of radiographs, radiological reports and clinical information for the interpretation of the MRI study. Radiographs were essential, very important or added information in 61-75% of all MSK MRI cases. Radiographs were judged as essential for reading of MRI studies more often for trauma, infection/inflammation and tumors than for degenerative and miscellaneous/normal diagnoses (χ 2 =60.95, df=16, P 2 =93.07, df=16, P<0.0001). The clinical and MRI diagnoses were the same or partially concordant significantly more often for tumors than for trauma, infection/inflammation and degenerative conditions, while in the miscellaneous/normal group they were different in 64% of cases. When the diagnoses were different, there were more instances in which radiographs were not available. Radiographs are an important, and sometimes essential, initial complementary study for reading of MSK MRI examinations. It is highly recommended that radiographs are available when MSK MRI studies are interpreted. (orig.)

  2. Effect of External Quality Assurance Evaluation for Chest Radiography: 3-Year Follow-Up in the Medical Institution for Pneumoconiosis

    International Nuclear Information System (INIS)

    Lee, Won Jeong; Choi, Soon Byung

    2012-01-01

    The aim of this study was to determine the effect of external quality assurance (QA) evaluation for chest radiography in the medical institution for pneumoconiosis (MIP). The chest radiography of the MIPs were evaluated for a radiological technique (RT), image quality (IQ), and reading environment (RE), during a 3-year follow up according to the Korean guidelines. Same methods were implemented each year to ensure that the results are reliable. RT, IQ, and RE were compared between examination and medical care (EMP), and only medical care (MCP) for pneumoconiosis, film-screen (FSR) and digital (DR) radiography. Uneducated and educated for QA during a 3-year follow up referencing with 2008 were realized. RT and IQ of the MIPs showed a significantly higher score in 2009 and 2010 compared with 2008 (p < 0.01). However, RE was not significantly improved. The score of RT, IQ, and RE of the EMPs were higher than those of MCPs every year, and FSR showed a lower score in all evaluations, although, more improvement was seen than the DR. The chest radiography of the MIPs showed a significant effect as a result of a repeated external QA evaluation. However, the MIPs need to transfer from FSR to DR, and maintain a continuous QA evaluation for the MCPs.

  3. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  4. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  5. WE-G-209-01: Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  6. Compact, open-architecture computed radiography system

    International Nuclear Information System (INIS)

    Huang, H.K.; Lim, A.; Kangarloo, H.; Eldredge, S.; Loloyan, M.; Chuang, K.S.

    1990-01-01

    Computed radiography (CR) was introduced in 1982, and its basic system design has not changed. Current CR systems have certain limitations: spatial resolution and signal-to-noise ratios are lower than those of screen-film systems, they are complicated and expensive to build, and they have a closed architecture. The authors of this paper designed and implemented a simpler, lower-cost, compact, open-architecture CR system to overcome some of these limitations. The open-architecture system is a manual-load-single-plate reader that can fit on a desk top. Phosphor images are stored in a local disk and can be sent to any other computer through standard interfaces. Any manufacturer's plate can be read with a scanning time of 90 second for a 35 x 43-cm plate. The standard pixel size is 174 μm and can be adjusted for higher spatial resolution. The data resolution is 12 bits/pixel over an x-ray exposure range of 0.01-100 mR

  7. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  8. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  9. Imaging of bone tumors: evaluation of direct magnification radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Hillmann, A.; Erlemann, R.; Groenefeld, A.; Haeussler, M.; Heppe, A.E.; Vestring, T.; Peters, P.E.

    1996-01-01

    Objective. To evaluate the potentials of magnification radiography as compared with conventional radiography in diagnosing bone tumors. Design and patients. Sixty-two patients with primary bone tumors and tumorlike lesions underwent radiography with both conventional (non-magnified) and magnification (fivefold) techniques. All radiographs were analyzed by four radiologists and the findings correlated with the histopathology findings. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. Digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Results. The diagnosis of benign and malignant lesions as well as the individual tumor diagnosis were determined with higher accuracy using magnification compared with conventional radiography (88% vs 75% and 71% vs 52%, p<0.01). Margins of destruction, periosteal reactions and matrix patterns were evaluated with higher certainty by all of the radiologists (p<0.01). Conclusion. Magnification radiography may improve the evaluation and diagnosis of bone tumors. (orig.). With 6 tabs

  10. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  11. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  12. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  13. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  14. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  15. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  16. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  17. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  18. Process waste assessment for the Radiography Laboratory

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie (μCi) activity. The photochemical processes generate most of the Radiography Laboratory's routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance

  19. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  20. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  1. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  2. Interprofessional working in diagnostic radiography

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.; Day, Jane

    2014-01-01

    This paper considers interprofessional working within one diagnostic imaging department. The literature is still divided about the long-term impact of interprofessional learning in pre-registration health and social care education, and its impact on the quality of care provided. When reading the literature about interprofessional working the main topics considered by other authors are team working, communication between professionals, stereotyping and tribalism. The results presented are from an ethnographic study in one department with participant observation and semi-structured interviews. The three main aspects discussed in this paper are; tribalism and culture within the diagnostic radiography profession, communication between different professional groups, and a lack of understanding of the roles of other professional groups. It was evident from the results of this study that tribalism and culture, and a lack of understanding were significant barriers to interprofessional working. It was felt by the authors that pre-registration and post-registration interprofessional education could be significant in changing the culture of the NHS in the future as more professionals learn from and about one another

  3. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  4. Radiography of pressure ulcers

    International Nuclear Information System (INIS)

    Borgstroem, P.S.; Ekberg, O.; Lasson, A.

    1988-01-01

    In patients with longstanding and/or deep pressure ulcers radiology is usually consulted. Survey radiography and sinography in 14 patients with pressure ulcers (6 over the tuber ischii and 8 over the femoral trochanter) were evaluated. Osteomyelitic involvement of adjacent bone was revealed in 9 patients on survey radiography. However, it was usually impossible to assess whether or not bony involvement represents healed or active osteomyelitis. Sinography did not contribute to the assessment of whether or not adjacent cortical bone was involved. However, when a fistulation to an adjacent joint was revealed this contributed substantially to the preoperative planning of resection. We therefore recommend that survey radiography and sinography should be included in the evaluation of these patients but that the results from such examinations are critically evaluated. Joint involvement should be taken seriously as progression of septic arthritis usually occurs rapidly. (orig.)

  5. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  6. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed. (author)

  7. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Full text: Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed

  8. Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

    Science.gov (United States)

    Hashim, Marina; Abidin, Diana Atiqah Zainal; Das, Simon K.; Ghaffar, Mazlan Abd.

    2014-09-01

    The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (Smax) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W2.93. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO4) paste injected in the wet shrimp in proportion to the body weight. The BaSO4 was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

  9. Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Hashim, Marina; Abidin, Diana Atiqah Zainal [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Das, Simon K. [Marine Ecosystem Research Centre, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi (Malaysia); Ghaffar, Mazlan Abd. [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Marine Ecosystem Research Centre, Faculty of Science and Technology, Universiti Kebangsaan M (Malaysia)

    2014-09-03

    The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (S{sub max}) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W{sup 2.93}. Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO{sub 4}) paste injected in the wet shrimp in proportion to the body weight. The BaSO{sub 4} was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity.

  10. Food consumption and digestion time estimation of spotted scat, Scatophagus argus, using X-radiography technique

    International Nuclear Information System (INIS)

    Hashim, Marina; Abidin, Diana Atiqah Zainal; Das, Simon K.; Ghaffar, Mazlan Abd.

    2014-01-01

    The present study was conducted to investigate the food consumption pattern and gastric emptying time using x-radiography technique in scats fish, Scatophagus argus feeding to satiation in laboratory conditions. Prior to feeding experiment, fish of various sizes were examined their stomach volume, using freshly prepared stomachs ligatured at the tips of the burret, where the maximum amount of distilled water collected in the stomach were measured (ml). Stomach volume is correlated with maximum food intake (S max ) and it can estimate the maximum stomach distension by allometric model i.e volume=0.0000089W 2.93 . Gastric emptying time was estimated using a qualitative X-radiography technique, where the fish of various sizes were fed to satiation at different time since feeding. All the experimental fish was feed into satiation using radio-opaque barium sulphate (BaSO 4 ) paste injected in the wet shrimp in proportion to the body weight. The BaSO 4 was found suitable to track the movement of feed/prey in the stomach over time and gastric emptying time of scats fish can be estimated. The results of qualitative X-Radiography observation of gastric motility, showed the fish (200 gm) that fed to maximum satiation meal (circa 11 gm) completely emptied their stomach within 30 - 36 hrs. The results of the present study will provide the first baseline information on the stomach volume, gastric emptying of scats fish in captivity

  11. Development of tungsten collimators for industrial radiography

    International Nuclear Information System (INIS)

    Varkey, P.A.; Verma, P.B.; Jayakumar, T.K.; Mammachan, M.K.

    2001-01-01

    Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)

  12. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  13. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  14. Digital and analogue industrial radiography, application fields

    International Nuclear Information System (INIS)

    Willems, Peter; Millord, Erik Yardin

    2000-01-01

    Full text: Reusable phosphor screens for computer radiography (CR), amorphous selenium screens for direct radiography (DR), film digitalisation (FD) constitute imaging methods accepted by industry and are used for non-destructive radiographic testing (RT). Economic pressures are involving and affecting digital RT technology. Standards and codes for film radiography and radioscopy qualification do no longer cover the wide range of digital RT applications. It will be our task to optimise the performance of digital RT characterisation and to create appropriate examination methods to use all these new and existent technologies. In the meantime, an increasing automation and control of manual methods of analogue radiography can as well be expected. (author)

  15. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  16. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  17. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  18. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  19. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  20. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  1. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  2. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  3. Information extraction from muon radiography data

    International Nuclear Information System (INIS)

    Borozdin, K.N.; Asaki, T.J.; Chartrand, R.; Hengartner, N.W.; Hogan, G.E.; Morris, C.L.; Priedhorsky, W.C.; Schirato, R.C.; Schultz, L.J.; Sottile, M.J.; Vixie, K.R.; Wohlberg, B.E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  4. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.

    Science.gov (United States)

    Reznik, Nikita; Komljenovic, Philip T; Germann, Stephen; Rowlands, John A

    2008-03-01

    A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cm x 40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.

  5. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

    International Nuclear Information System (INIS)

    Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico

    2011-01-01

    Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

  6. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  7. SIMPLE for industrial radiography

    International Nuclear Information System (INIS)

    Azhar Azmi; Abd Nassir Ibrahim; Siti Madiha Muhammad Amir; Glam Hadzir Patai Mohamad; Saidi Rajab

    2004-01-01

    The first thing industrial radiographers have to do before commencing radiography works is to determine manually the amount of correct exposure that the film need to be exposed in order to obtain the right density. The amount of exposure depends on many variables such as type of radioisotope, type of film, nature of test-object and its orientation, and specific arrangement related to object location and configuration. In many cases radiography works are rejected because of radiographs fail to meet certain reference criteria as defined in the applicable standard. One of the main reasons of radiograph rejection is due to inadequate exposure received by the films. SIMPLE is a software specially developed to facilitate the calculation of gamma-radiography exposure. By using this software and knowing radiographic parameters to be encountered during the work, it is expected that human error will be minimized, thus enhancing the quality and productivity of NDT jobs. (Author)

  8. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  9. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  10. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  11. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  12. Industrial Radiography: Principle and Practical

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The successful and effectiveness of radiography method as a tool to increase quality level and safety of the engineering system and processing plants depend with the level of radiographer knowledge as service provider and also as supervisor. This book was published as effort several local experts to give their knowledge, theory and practical related to radiography technique to the involved public directly or indirectly. This book started with basic physic knowledge that becomes a root to radiography technology. Then, followed by discussion on tools and device that used in radiography work including x-ray machine, gamma projector, film, dark room, and others. Each aspect of radiograph quality also mentioned here to guide the reader on how to produce good radiograph that filled the specification wanted. The good radiograph does not mean anything if it failed to be interpreted correctly. Because of that, this book also explain how to choose good radiograph that qualified to be interpreted and after that how interpretation and evaluation process of object quality inspected was implemented based on image digestion that showed in radiograph. Several code and standard that usually applied in this country also will be referred as well for this work.

  13. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  14. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in … shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  15. Radiation Safety in Industrial Radiography. Specific Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  16. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  17. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  18. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  19. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  20. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  1. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  2. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  3. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  4. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  5. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  6. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  7. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  8. Need for New Optimisation Strategies in CR and Direct Digital Radiography

    International Nuclear Information System (INIS)

    Busch, H.P.

    2000-01-01

    Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference values for the dose and the image quality. This has to be done first for single exposures and fluoroscopic mode and secondly for diagnostic and interventional procedures. (author)

  9. Collaboration in radiography: A bibliometric analysis

    International Nuclear Information System (INIS)

    Snaith, Beverly

    2012-01-01

    Introduction: Increasing research activity is an aim of the radiography profession, but there is a lack of knowledge of how this can be achieved. Collaboration between clinical and academic centres as well as between individuals has increased productivity in other professions and has been suggested as a strategy for radiography. This bibliometric study maps the current contribution to the radiography evidence base through a single journal. Method: All articles published in Radiography from 1997 to 2011 were reviewed to identify collaboration trends together with article type and subject. Analysis also enabled comparison of research and publication patterns. Results: 706 articles were published by 1205 individual authors. 63.0% were written by UK based authors, although this varied over time. Over 80% of authors published only single article. Two thirds of articles were collaborative with an increase in clinical-academic co-authorship over the 15 years of the study. Although the majority of articles were diagnostic imaging based, the pattern mirrors the UK workforce profile. Clinicians, including clinical-academic co-authors, tend to write about clinical practice and roles, whereas academics write about a broader range of topics. Conclusions: There has been a growth in research and scholarship within the UK radiography journal and both clinical and academic radiographers are contributing to the evidence base through increased collaboration.

  10. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  11. Radiography of steel castings by radioisotopes

    International Nuclear Information System (INIS)

    Agrawal, D.K.

    1977-01-01

    The salient features of isotope radiography techniques in the inspections of alloy castings are described. Some of the typical radiographic tests conducted in the Bharat Heavy Electricals Ltd., Bhopal and the problems encountered are described in detail. Specific examples are cited to enlighten the benefits of isotope radiography in heavy industries. (author)

  12. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  13. Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography

    International Nuclear Information System (INIS)

    Grunert, J.H.; Borchert, B.; Farber, A.; Gmelin, E.

    1999-01-01

    Aims of the study: The purpose of this study was to investigate the efficacy of 4-fold magnification breast specimen radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography in evaluating the presence of absence of carcinoma at the surgical margins by detection of microcalcification. Results: In 50 specimen 2821 (1305 within 3 mm distance to the margins) microcalcifications were detected with the DIMA mammography technique compared to 1608 (446) microcalcifications with the conventional technique. This increased detection rate by DIMA-magnetification radiography was accompanied by a decreased specificity in comparison to the conventional magnification radiography (33,3% DIMA versus 83,3% conventional) regarding the evaluation of presence or absence of carcinoma at the surgical margins. Differentiating the microcalcifications into calcifications belonging to the suspicious cluster and those that are located outside the cluster led to an increase in specificity (83,3% DIMA versus 100% conventional). Conclusions: The efficacy of breast specimens radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification is not improved by 4-fold magnification radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography due to an increase in false-positive results. Analysis of the attachement of the microcalcifications to the cluster can improve the specificity. (orig.) [de

  14. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... industrial radiography. An application for a specific license for the use of licensed material in industrial...

  15. Lateral radiography of the knee with single-leg standing

    International Nuclear Information System (INIS)

    Ohmori, Kan; Sugawara, Tsuyoshi; Murakami, Katsuyoshi; Kirinai, Mikio; Fujiwara, Junichi; Oikawa, Takumi; Matsumura, Yutaka; Sugawara, Tsukasa

    2002-01-01

    The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography. (author)

  16. Fundamental of neutron radiography and the present of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Sekita, Junichiro

    1988-01-01

    Neutron radiography refers to the application of transmitted neutrons to analysis. In general, thermal neutron is used for neutron radiography. Thermal neutron is easily absorbed by light atoms, including hydrogen, boron and lithium, while it is not easily absorbed by such heavy atoms as tungsten, lead and uranium, permitting detection of impurities in heavy metals. Other neutrons than thermal neutron can also be applied. Cold neutron is produced from fast neutron using a moderator to reduce its energy down to below that of thermal neutron. Cold neutron is usefull for analysis of thick material. Epithermal neutron can induce resonance characteristic of each substance. With a relatively small reaction area, fast neutron permits observation of thick samples. Being electrically neutral, neutrons are difficult to detect by direct means. Thus a substance that releases charged particles is put in the path of neutrons for indirect measurement. X-ray film combined with converter screen for conversion of neutrons to charge particles is placed behind the sample. Photographing is carried out by a procedure similar to X-ray photography. Major institues and laboratories in Japan provided with neutron radiography facilities are listed. (Nogami, K.)

  17. Industrial radiography

    International Nuclear Information System (INIS)

    Aloni, A.; Magal, O.

    1992-02-01

    This publication is meant to be a manual for industrial radiography. As such the manual concentrates on the practical aspects, presenting existing radiographic system and techniques of operation to satisfy specified quality requirements. The manual also reviews the safety aspect of performing radiographic work. (author) systems

  18. Skull Radiography

    Science.gov (United States)

    What you need to know about… Skull Radiography X-ray images of the skull are taken when it is necessary to see the cranium, facial bones or jaw bones. ... Among other things, x-ray exams of the skull can show fractures. Patient Preparation Before the examination, ...

  19. Radiography and bone scintigraphy in multiple myeloma: a comparative analysis

    International Nuclear Information System (INIS)

    Ludwig, H.; Kumpan, W.; Sinzinger, H.

    1982-01-01

    The sensitivity of radionuclide imaging for detecting skeletal lesions was compared with that of radiography by evaluating 573 different anatomical sites in 41 patients with multiple myeloma. Radiography revealed a significantly greater number of myeloma-related bone lesions than did radionuclide imaging. Of the 179 myeloma-related bone lesions detected when both techniques were applied, 163 were seen by radiography and 82 by radionuclide imaging. Ninety-seven lesions were detected by radiography alone and 16 lesions seen by scintiscanning only, yielding a sensitivity of 91% for the former and of 46% for the latter technique. Radionuclide imaging proved superior to radiography only occasionally in the rib cage, and rarely in other anatomical sites. These findings suggest that radiography is the method of first choice in obtaining a skeletal survey in patients with multiple myeloma. In cases with continued pain, unexplained by standard radiography, the skeletal survey should be supplemented by tomography and radionuclide imaging. (author)

  20. Security of radioactive sources in industrial radiography

    International Nuclear Information System (INIS)

    Popp, Andrew; Murray, Allan

    2010-01-01

    This paper describes the need and new requirements to ensure the security of radioactive sources used in the practice of industrial radiography. We describe the discussions and issues arising during the september 2010 regional workshop held in Sydney on the application of security measures to industrial radiography practices. The workshop provided the perspectives of both radiation regulators and industry practitioners, including those from the Philippines. We describe the outputs of the workshop, and how they were developed, and make suggestions for further consideration and applications of security measures in the practice of industrial radiography. (author)

  1. Charter of good practices in industrial radiography

    International Nuclear Information System (INIS)

    2010-01-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  2. Corrosion Surveillance In Pipe By Computed Radiography

    International Nuclear Information System (INIS)

    Nguyen The Man; Dao Duy Dung; Dang Thu Hong; Le Duc Thinh; Ha Hong Thu; Nguyen Trong Nghia

    2014-01-01

    Computed Radiography (CR) is a technique of digital industrial radiology which is developed to replace conventional radiography. With a CR system, the detection of the outer and inner wall surface of the pipe is done usually by edge detection and filter algorithms of the profile line at the position under investigation. Applying in industries, radiographic examination shall be performed in accordance with a written procedure. This paper summarizes collected knowledge and experimental results to establish a procedure for radiography applications in monitoring corrosion in small bore pipes. (author)

  3. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  4. Application of computed radiography to ERCP

    International Nuclear Information System (INIS)

    Lee, Shigeki; Mochizuki, Fukuji; Fujita, Naotaka; Itoh, Shoichiro; Ikeda, Takashi; Toyohara, Tokiaki; Matsumoto, Kyoichi

    1984-01-01

    Computed radiography technic was applied to ERCP. Fuji Computed Radiography System was used. The pancreatogram obtained by this method was compared with that of conventional screen-film radiograph. The much finer changes of the pancreatogram can be delineated by the new method. The diagnostic ability of ERCP is thus enhanced by the introduction of FCR. (author)

  5. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  6. Radiography of X-ray in coral reefs

    International Nuclear Information System (INIS)

    Djoli Soembogo

    2016-01-01

    The application of X-ray radiography has been developed and it is already widely used in metal materials such as metal steel and carbon steel. This radiography using a source of radiation from X-ray machines. This research attempts to use the application of digital radiography X-ray source and use scanner Epson V700 positive films media for digitization results of conventional radiographic films on coral reefs. It has been testing radiography using Fuji film 100 to get the contrast medium, the sensitivity of the medium and image quality is good, Single Wall Single Image method , and using the media scanner films positive and X-ray sources, observation parameter are density radiographic film and the defect shape. Radiography uses Fuji film 100 to obtain a good contrast medium, good medium sensitivity and good quality image. Radiography of X-ray on coral reefs aims to find defects or discontinuities coral reefs such as porosity which would interfere with the determination of the age of the coral reefs. X-ray exposure time is 1 seconds for a thickness of 5.45 mm and 5.60 mm coral reefs by using a high voltage X-ray machine Rigaku of 130 kV. The result of the positive film scanner in the form of digital radiography that allows for the transfer of digital data or digital computerized data storage. The test results of radiographic on coral reefs with Single Wall Single Image method obtained radiographic film density parameter for Fuji film 100 on coral reefs No. 2 are 2.55; 2.53; 2.59 and on coral reefs No. 4 are 2.62; 2.65; 2.66, unsharpness geometric of radiographic results obtained 0.022 mm and 0.023 mm, sensitivity radiography are 1.648% and 1.604%. No defect found of Porosity that is significant. Status is acceptable for Fuji film 100, because the density of the film is in conformity with the standards referred to. Status of coral reefs No. 2 and No. 4 can be accepted, because it has conformed with the standards referred. (author)

  7. Feasibility study of gamma-ray medical radiography

    International Nuclear Information System (INIS)

    Alyassin, Abdalmajeid M.; Maqsoud, Hamza A.; Mashat, Ahmad M.; Al-Mohr, Al-Sayed; Abdulwajid, Subhan

    2013-01-01

    This research explores the feasibility of using gamma-ray radiography in medical imaging. We will show that gamma-ray medical radiography has the potential to provide alternative diagnostic medical information to X-ray radiography. Approximately one Ci Am-241 radioactive source which emits mono-energetic 59.5 keV gamma rays was used. Several factors that influence the feasibility of this study were tested. They were the radiation source uniformity, image uniformity, and image quality parameters such as contrast, noise, and spatial resolution. In addition, several gamma-ray and X-ray images were acquired using humanoid phantoms. These images were recorded on computed radiography image receptors and displayed on a standard monitor. Visual assessments of these images were then conducted. The Am-241 radioactive source provided relatively uniform radiation exposure and images. Image noise and image contrast were mainly dependent on the exposure time and source size, whereas spatial resolution was dependent on source size and magnification factor. The gamma-ray humanoid phantom images were of lower quality than the X-ray images mainly due to the low radioactivity used and not enough exposure time. Nevertheless, the gamma-ray images displayed most of the main structures contained in the humanoid phantoms. Higher exposure rates and thus lower exposure times were estimated for different pure Am-241 source sizes that are hypothesized to provide high quality images similar to X-ray images. For instance, a 10 mm source size of pure Am-241 with 7 s exposure time should produce images similar in contrast and noise to X-ray images. This research paves the way for the production and usage of a highly radioactive Am-241 source with the potential to lead to the feasibility of acceptable quality medical gamma-ray radiography. - Highlights: ► Characterized the performance of gamma-ray radiography. ► Displayed medical images of humanoid phantoms using gamma radiography. ► Am-241

  8. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  9. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  10. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  11. Gravity sag view of lateral radiography of the knee

    International Nuclear Information System (INIS)

    Hidaka, Kuniyuki; Yanagawa, Yasuhiro; Kawamoto, Kiyosumi; Maeda, Daisuke; Komizu, Mitsuru

    2007-01-01

    The gravity sag view (GSV) is a lateral radiograph taken in the same position when the posterior sag sign is observed. The purpose of this study was to standardize the radiography technique for GSV by adjusting lateral rotation. To confirm the benchmark and correction angle (CA) for the GSV position, we assessed three-dimensional (3D) CT of the GSV position of the knee using normal volunteers. The benchmark is established at the 3-point of the leg and adjusting the CA of the knee is established by estimating from Rosenberg technique radiography. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate in adjusting lateral radiography of the knee. (author)

  12. A Political Radio Poetics: Ouyang Yu’s Poetry and its Adaptation on ABC Radio National’s Poetica

    Directory of Open Access Journals (Sweden)

    Prithvi Varatharajan

    2017-11-01

    Full Text Available ‘Ouyang Yu’ was an episode that aired on ABC Radio National’s 'Poetica', a weekly program broadcast across Australia from 1997 to 2014. The episode featured readings of poetry by the contemporary Chinese-Australian poet Ouyang Yu, read by the poet and by the actor Brant Eustace. These readings were embedded in rich soundscapes, and framed by interviews with the poet on the thematic contexts for the poems. In this article I treat ‘Ouyang Yu’ as an adaptation of Ouyang’s work, in Linda Hutcheon’s sense of the term. I examine how Ouyang’s poetry has been adapted for a national audience, and pay particular attention to how contemporary political discourses of nationhood have influenced the episode’s adaptations. For Poetica existed within an institution—the ABC—whose culture had a bearing on its programming, and the ABC was in turn influenced by, and sought to influence, the wider social and political culture in Australia.

  13. Comparison of sputum acid-fast culture and chest radiography in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Lim, G.M.

    1991-01-01

    While it is still a common practice of some clinicians to rely on chest radiography examination alone for the diagnosis of pulmonary tuberculosis, others still claim that absolute diagnosis of tuberculosis can firmly be established by bacteriological examination from secretions or tissues of the infected host. This study will evaluate the relationship between radiographic findings (CXR) and the likelihood of finding tubercle bacilli on sputum acid-fast bacilli (AFB) culture in pulmonary tuberculosis at Lung Center of the Philippines. Of 41 individuals who submitted their sputum for AFB culture, tubercle bacilli in the sputum was shown in 25 (60%) of cases and no growth of tubercle bacilli in 16 (40%) of cases. Chest radiography reading revealed tuberculosis in 100% of cases, of which when classified further, 22 (54%) has fibrohazed or hazy infiltrates on their CXR, 7 (17%) has cavitations or interpreted as moderate or far advanced TB, 12 (29%) has fibroid, nodular infiltrates or densities. In patients radiologically diagnosed as PTB minimal, sputum culture revealed tubercle bacilli in 15 (57%) among moderate, far advanced tuberculosis, and 6 (50%) among those with inactive or old tuberculosis. Therefore, the probability of detecting tubercle bacilli in pulmonary tuberculosis is not greatly influenced by radiographic findings. (auth.). 11 refs.; 2 figs.; 2 tabs

  14. Opportunities for TRIGA reactors in neutron radiography

    International Nuclear Information System (INIS)

    Barton, John P.

    1978-01-01

    In this country the two most recent installations of TRIGA reactors have both been for neutron radiography, one at HEDL and the other at ANL. Meanwhile, a major portion of the commercial neutron radiography is performed on a TRIGA fueled reactor at Aerotest. Each of these installations has different primary objectives and some comparative observations can be drawn. Another interesting comparison is between the TRIGA reactors for neutron radiography and other small reactors that are being installed for this purpose such as the MIRENE slow pulse reactors in France, a U-233 fueled reactor for neutron radiography in India and the L88 solution reactor in Denmark. At Monsanto Laboratory, in Ohio, a subcritical reactor based on MTR-type fuel has recently been purchased for neutron radiography. Such systems, when driven by a Van de Graaff neutron source, will be compared with the standard TRIGA reactor. Future demands on TRIGA or competitive systems for neutron radiography are likely to include the pulsing capability of the reactor, and also the extraction of cold neutron beams and resonance energy beams. Experiments recently performed on the Oregon State TRIGA Reactor provide information in each of these categories. A point of particular current concern is a comparison made between the resonance energy beam intensity extracted from the edge of the TRIGA core and from a slot which penetrated to the center of the TREAT reactor. These results indicate that by using such slots on a TRIGA, resonance energy intensities could be extracted that are much higher than previously predicted. (author)

  15. Digital radiography: a survey of pediatric dentists.

    Science.gov (United States)

    Russo, Julie M; Russo, James A; Guelmann, Marcio

    2006-01-01

    The purpose of this study was to: (1) determine the popularity of digital radiography among members of the American Academy of Pediatric Dentistry (AAPD); and (2) report the most common systems in use. An AAPD-approved, voluntary, and anonymous electronic survey was developed and sent to 923 board certified pediatric dentists. Years in practice and in-office x-ray technology (digital or conventional) were inquired about initially. If negative for the use of digital radiography, future consideration for converting to digital radiography was ascertained. For positive responses, more in-depth information was requested. Information on type of system (sensor or phosphor plate), user friendliness, diagnostic ability, patient's comfort, general costs, durability, and parental and overall satisfaction was collected. For most of the questions, a 5-point assessment scale was used. Opportunity for additional comments was provided upon survey completion. Data was analyzed using descriptive statistics. A 32% (296/923) response rate was obtained. Twenty-six percent of practitioners (78/296) implemented digital radiography in their practices, whereas 71% considered future acquisition. Similar distribution for sensor and phosphor plate users was found. Sensor technology was reported to produce faster images, but was less tolerable by young children due to size and thickness. Phosphor plates were considered more children friendly, less expensive, and less durable. Parental satisfaction was very high with great marketing value. Picture quality was comparable to conventional film. Overall, digital radiography users would recommend it to other pediatric dentists. Digital radiography is not yet popular among pediatric dentists. Cost reduction and technology advancement may enhance utilization.

  16. Application of proton radiography to medical imaging

    International Nuclear Information System (INIS)

    Kramer, S.L.; Martin, R.L.; Moffett, D.R.; Colton, E.

    1977-12-01

    The use of charged particles for radiographic applications has been considered for some time, but progress has been impeded by the cost and availability of suitable accelerators. However, recent developments in technology could overcome these problems. A review is presented of the physical principles leading to an improvement in mass resolution per unit of absorbed dose for charged particle radiography relative to x-ray radiography. The quantitative comparisons between x-ray and proton radiographs presented here confirm this advantage. The implications of proton radiography on cancer detection, as well as future plans for developing a proton tomographic system, are discussed

  17. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  18. The industrial radiography of defects inside the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt; Kaempf, B.

    1976-03-01

    The concept of the industrial radiography applied to defect invesigation is defined. The following topics are successively discussed: the development of the industrial 'defect radiography', apparatus and auxiliary equipments used in the field, the market, the constructors, trade currents in 'defect radiography' inside the Community and in the outer market; prognostics on future requirements in the fields

  19. Diagnostic value of digital radiography compared to conventional screen-film system combinations

    International Nuclear Information System (INIS)

    Krug, B.; Zaehringer, M.; Lackner, K.

    1997-01-01

    Digital projection radiography provides digital data in X-ray examinations, which used to be carried out by examinations screen-film system combinations. The technological basis and clinical performances of digital luminescent radiography (DLR) and digital radiography are reviewed. Digital projection radiography does not allow to reduce selenium exposure significantly, compared to screen-film system combinations. Digital luminescent radiography can be used for the entire spectrum of analogous projection radiography the only exception being extremely subtile structural changes. The clinical experiences with digital selenium radiography achieved so far in chest X-rays are promising and the technique is expected to be increasing used in other anatomic regions as well. (orig.) [de

  20. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  1. Code of practice in industrial radiography

    International Nuclear Information System (INIS)

    Karma, S. E. M.

    2010-12-01

    The aim of this research is to developing a draft for a new radiation protection code of practice in industrial radiography without ignoring that one issued in 1998 and meet the current international recommendation. Another aim of this study was to assess the current situation of radiation protection in some of the industrial radiography department in Sudan. To achieve the aims of this study, a draft of a code of practice has been developed which is based on international and local relevant recommendations. The developed code includes the following main issues: regulatory responsibilities, radiation protection program and design of radiation installation. The practical part of this study includes scientific visits to two of industrial radiography departments in Sudan so as to assess the degree of compliance of that department with what state in the developed code. The result of each scientific visits revealed that most of the department do not have an effective radiation protection program and that could lead to exposure workers and public to unnecessary dose. Some recommendations were stated that, if implemented could improve the status of radiation protection in industrial radiography department. (Author)

  2. Safety culture in industrial radiography facility

    International Nuclear Information System (INIS)

    Vincent-Furo, Evelyn

    2015-02-01

    This project reviewed published IAEA materials and other documents on safety culture with specific references to industrial radiography. Safety culture requires all duties important to safety to be carried out correctly, with alertness, due thought and full knowledge, sound judgment and a proper sense of accountability. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements. The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve a high degree of safety culture appropriate national and international infrastructure should exist to ensure effective training of workers and management system that supports commitment to safety culture at all level of the organization; management, managers and workforce. The result of the review revealed that all accidents in industrial radiography facilities were due to poor safety culture practices including inadequate regulatory control oversight. Some recommendations are provided and if implemented could improve safety culture leading to good safety performance which will significantly reduce accidents and their consequences in industrial radiography. These examples call for a review of safety culture in Industrial radiography. (au)

  3. Portable radiography using linear accelerators

    International Nuclear Information System (INIS)

    Reid, D.W.

    1984-01-01

    There are numerous instances where the availability of a portable high-energy radiography machine that could be transported to the inspection site with relative ease would save time, money, and make radiography of permanent installations, such as bridges, possible. One such machine, the Minac built by Schoenberg Radiation Inc., is commercially available. It operates at 9.3 GHz, has an electron energy on target of 3.5 MeV, and an output dose rate of 100 R/min. A second portable accelerator, recently completed at the Los Alamos National Laboratory, operates at 2.998 GHz, has electron energies on target of 6, 8, and 10 MeV, and an output dose rate of 800 R/min at 8 MeV. This paper discusses the need for and applications of portable accelerators for radiography. Physical characteristics and beam parameters of both machines are examined in detail. Problems of operating at higher frequencies to further minimize size and weight are discussed

  4. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Computed Radiography Exposure Indices in Mammography. L Koen, C Herbst, W Rae. Abstract. Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose ...

  5. Application of direct digital radiography of nasal bone

    International Nuclear Information System (INIS)

    Gao Dengfa; Wang Haijun; Zhang Ailian; Wang Yulin

    2005-01-01

    Objective: To research the application value of direct digital radiograph (DDR ) in nasal bone imaging. Methods: One hundred cases were examined by DDR, 30 cases of them were examined by two methods both DDR and conventional radiography. All digital images were post-processed with 'MUSICA' (Multi-Scale Image Contrast Amplification), incision and largamente, analyzed and diagnosed by experienced two radiologists and two technicians. Results: One hundred cases of nasal bone, soft tissue of nose were showed excellent in DDR, and satisfactory cases were 95 and 92, respectively. Forty-six cases of nasal bone fractures were found. Thirty cases were examined by both DDR and conventional radiography, images of nasal bone, soft tissue of nose were showed, satisfactory cases were 28 in DDR; and satisfactory cases were 6 (χ 2 =20.05, P 2 =15.06, P 2 =5.14, P<0.05) in conventional and digital radiography, respectively. Conclusion: DDR images of nasal bone, soft tissue of nose was excellent, more fractures were discovered than conventional radiography. Image quality of DDR is better than conventional radiography in nasal bone imaging. (authors)

  6. Evaluation of occupational exposure in intraoral radiography; Avaliacao da dose ocupacional em radiografia intraoral

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C., E-mail: miguel_cristianoch@yahoo.com.br, E-mail: saicla@utfpr.edu.br, E-mail: annarocha@yahoo.com, E-mail: walmor.godoi@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Tilly Junior, Joao G., E-mail: joao.tilly@derax.com.br [Universidade Federal do Parana (HC/UFPR), Curitiba, PR (Brazil). Hospital das Clinicas

    2014-07-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  7. Bacteriological research for the contamination of equipment in chest radiography

    International Nuclear Information System (INIS)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol

    2015-01-01

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections

  8. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  9. Radiation-absorbed doses and energy imparted from panoramic tomography, cephalometric radiography, and occlusal film radiography in children

    International Nuclear Information System (INIS)

    Bankvall, G.; Hakansson, H.A.

    1982-01-01

    The absorbed doses and energy imparted from radiographic examinations of children, using panoramic tomography (PTG), cephalometric radiography (CPR), and maxillary frontal occlusal overview (FOO), were examined. The absorbed dose at various sites of the head were measured with TL dosimeters in a phantom and in patients. The energy imparted was calculated from measurements of areal exposure using a planparallel ionization chamber. The maximum absorbed doses for panoramic tomography were located around the lateral rotation center, for cephalometric radiography in the left (tube side) parotid region, and for frontal occlusal radiography in the nose. The absorbed doses in the eyes, thyroid gland, and skin are discussed and compared with previous reports and, for the most part, are found to be in agreement. The mean energy imparted from all three examination methods is 5 mJ with about 57 percent from panoramic, 33 percent from cephalometric, and 10 percent from frontal occlusal examinations. The energy imparted from cephalometric radiography can be reduced to about 10 percent with the use of an improved examination technique, leaving panoramic tomography responsible for contributing about 80 percent of the total energy imparted

  10. Reproducible positioning in chest X-ray radiography

    International Nuclear Information System (INIS)

    1974-01-01

    A device is described that can be used to ensure reproducibility in the positioning of the patient during X-ray radiography of the thorax. Signals are taken from an electrocardiographic monitor and from a device recording the respiratory cycle. Radiography is performed only when two preselected signals coincide

  11. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  12. Visualization of frosting phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Yoshimura, Tomoya; Matsumoto, Ryosuke; Umekawa, Hisashi; Ami, Takeyuki; Saito, Yasushi

    2012-01-01

    This study focuses on the frost formation on the fin-tube heat exchanger using neutron radiography. The visualization of the frost formation was estimated by the attenuation of the neutron beam through the water. The visualization image of the neutron radiography shows clearly the frost formation phenomena on the fin-tube heat exchanger. The rapid frost formation was observed at the fin and tube edges. Local mass transfer coefficient can be calculated from the differential images of the neutron radiography. (author)

  13. Survey of the Satisfaction and Dissatisfaction of Referring Physicians Concerning the Radiologic Report of Plain Radiography Except for Chest Plain Radiography

    International Nuclear Information System (INIS)

    Moon, Soon Young; Park, Noh Hyuck; Kim, Mi Sung; Park, Chan Sub; Park, Ji Yeon; Park, Hee Jin; Kim, Sam Soo; Jeon, Hyun Jun

    2011-01-01

    To assess the satisfaction, attitude, dissatisfaction and general opinion of radiologic reports on the plain radiography, except for chest plain radiographs. A questionnaire was distributed to the 63 physicians of our hospital. The questionnaire aimed to investigate physician's general attitude, dissatisfaction and opinions. The responses elicited, as well as discrepancies among residents, staff, medical clinicians and surgical clinicians were assessed. Chi-square and t-tests were used to determine the value of the data. The mean rate of satisfaction for the reading report by medical clinicians (64%) was higher than surgical clinicians (25%) (p < 0.001). The mean satisfaction score was 3.1 (2.8-3.61). The main cause for dissatisfaction was the absence of reports when they were needed, especially for residents. The medical clinician's dependence on radiologic reports was higher than that of the surgical clinicians. The satisfaction score was in the middle range and the main cause of dissatisfaction was absence of the reports when they were needed.

  14. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION... Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  15. Safety guide of safe use of industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    The objective of this guidance is to present general regulations for the safe use and radiation protection of industrial radiography. Storage and inspection of apparatus, personal instructions for working in radiography facilities are offered

  16. Radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Panaiotov, L N

    1951-10-23

    A new method of hollow articles radiography is presented enabling to eliminate shortcomings coupled with medical personnel irradiation when the ampoule incorporating radioactive substance is removed from the protective container and adjusted in the article. The method presented permits to transport the ampoule from the protective container immediately into the inner cavity of the article.

  17. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    Science.gov (United States)

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  19. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  20. Compton radiography, 4. Magnification compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, S; Sera, K; Shishido, F; Fukuda, H [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis and Cancer; Mishina, H

    1978-03-01

    Compton radiography permits an acquisition of direct magnification Compton radiograms by use of a pinhole collimator, rendering it feasible to overcome the resolution of the scinticamera being employed. An improvement of resolution was attained from 7 mm to 1 mm separation. Usefulness of its clinical application can be seen in orientation of puncture and biopsy in deep structures and detection of various foreign bodies penetrated by blasts and so on under the ''magnification Compton fluoroscopy'' which can be developed on this principle in the near future.

  1. Time-grated energy-selected cold neutron radiography

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Brun, T.O.; Claytor, T.N.; Farnum, E.H.; Greene, G.L.; Morris, C.

    1998-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as Time-Gated Energy-Selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross section drops significantly. This difference in scattering characteristics can be recorded in the TGES radiography and, because the Bragg cutoff occurs at different energy levels for various materials, the approach can be used to differentiate among these materials. This paper outlines the TGES radiography technique and shows an example of radiography using the approach

  2. Digital radiography in space.

    Science.gov (United States)

    Hart, Rob; Campbell, Mark R

    2002-06-01

    With the permanent habitation of the International Space Station, the planning of longer duration exploration missions, and the possibility of space tourism, it is likely that digital radiography will be needed in the future to support medical care in space. Ultrasound is currently the medical imaging modality of choice for spaceflight. Digital radiography in space is limited because of prohibitive launch costs (in the region of $20,000/kg) that severely restrict the volume, weight, and power requirements of medical care hardware. Technological increases in radiography, a predicted ten-fold decrease in future launch costs, and an increasing clinical need for definitive medical care in space will drive efforts to expand the ability to provide medical care in space including diagnostic imaging. Normal physiological responses to microgravity, in conjunction with the high-risk environment of spaceflight, increase the risk of injury and could imply an extended recovery period for common injuries. The advantages of gravity on Earth, such as the stabilization of patients undergoing radiography and the drainage of fluids, which provide radiographic contrast, are unavailable in space. This creates significant difficulties in patient immobilization and radiographic positioning. Gravity-dependent radiological signs, such as lipohemarthrosis in knee and shoulder trauma, air or fluid levels in pneumoperitoneum, pleural effusion, or bowel obstruction, and the apical pleural edge in pneumothorax become unavailable. Impaired healing processes such as delayed callus formation following fracture will have implications on imaging, and recovery time lines are unknown. The confined nature of spacecraft and the economic impossibility of launching lead-based personal protective equipment present significant challenges to crew radiation safety. A modified, free-floating radiographic C-arm device equipped with a digital detector and utilizing teleradiology support is proposed as a

  3. Radiation protection in dental radiography

    International Nuclear Information System (INIS)

    Jozani, F.; Parnianpour, H.

    1976-08-01

    In considering the special provisions required in dental radiography, investigations were conducted in Iran. Radiation dose levels in dental radiography were found to be high. Patient exposure from intraoral radiographic examination was calculated, using 50kV X-ray. Thermoluminescent dosimeters were fastened to the nasion, eyes, lip, philtrum, thyroid, gonads and to the right and left of the supra-orbital, infra-orbital temporomandibular joints of live patients. The highest exposure value was for the lower lip. Recommendations concerning educational training and protection of staff and patients were included

  4. Educational aspects of industrial radiography

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Wamorkar, R.R.; Singh, G.

    1979-01-01

    The state of art of training and education in non-destructive testing in India, with special reference to industrial radiography is reviewed. Basic requirement of industry and potential of radioisotopes in industrial inspection are also described. Need for an organised training programme in industrial isotope radiography to exploit potentials for benefit of industry concurrent with the safety is stressed. A comprehensive training programme tailored to meet the needs of Indian industry is outlined. Benefits obtained from the course to the industry since the beginning of the training programme are briefly reviewed. (auth.)

  5. Muon radiography method for fundamental and applied research

    Science.gov (United States)

    Alexandrov, A. B.; Vladymyrov, M. S.; Galkin, V. I.; Goncharova, L. A.; Grachev, V. M.; Vasina, S. G.; Konovalova, N. S.; Malovichko, A. A.; Managadze, A. K.; Okat'eva, N. M.; Polukhina, N. G.; Roganova, T. M.; Starkov, N. I.; Tioukov, V. E.; Chernyavsky, M. M.; Shchedrina, T. V.

    2017-12-01

    This paper focuses on the basic principles of the muon radiography method, reviews the major muon radiography experiments, and presents the first results in Russia obtained by the authors using this method based on emulsion track detectors.

  6. Studies on the Fuji computed radiography depended on the panoramic radiography

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Shiota, Satoru; Takazawa, Kazuyoshi; Yoshida, Toru; Takagi, Yoshiko; Funamoto, Choichiro

    1986-01-01

    The Fuji Computed Radiography (FCR) developed recently involves the following procedures; photography in the same way as the hitherto radiography, printing auto imaging plate of photostimulable phospher, conversion to electric signals, and recording reproduced images by computerization. Highly valuable images for diagnoses in the medical field have already been obtained by the FCR. Then, we attempted to study FCR images panoramically radiographed for jaw lesions in the field of oral surgery. Method for study: As the samples to be studied, the selected subjects were cases of periodontal diseases, fracture of the jaw, odontogenic cyst and tumor, etc. In the present study the FCR images of panoramic radiography were compared with hitherto panoramic flat radiograms. Result of study: Although the images of the FCR vary depending on the methods of treatment, that is, on how gradient processing and spatial frequency enhancement are, the method of purpose-fitting treatment provided diagnostically significant images for grasping bone lesions. The images obtained from this FCR permitted us to grasp more distinctly condition of alveolar bone resorption in periodontal diseases, running of minute fracture lines in fracture of the jaw, and characteristic images of bone resorption in odontogenic cysts and tumor, etc. Thus the images of the FCR are highly useful in diagnosing bone lesions, but granularity of the images themselves have still been questioned, and additionally the images vary depending on the methods of gradient processing and spatial frequency enhancement. Therefore further repeat studies are probably needed for these questions. (author)

  7. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  8. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  9. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  10. Introduction to industrial radiography

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the first topic in this book, more on introduction to nondestructive testing, also a little bit on another technique such as magnetic testing, liquid penetrated, ultrasonic testing and others. This book mentions more on radiographic testing and for that, more details on this topic such as history, definition and devices that use in this technique. This radiography testing firstly started with the discovering of x-ray by Wilhelm Roentgen (1895). So, on 1913, David Coolidge successfully invented and developed x-ray tube that could made x-ray more intensified and produced highly penetration forces. Radiography in Malaysia firstly started two years after the discovery made by Wilhelm Roentgen when one hospital here used the x-ray machine for medical purposes. Besides using x-ray, radiography also used gamma rays, and for these purpose, they used Co-60 and Ir-192. Now, more company based on NDT established to provide a service on inspection pipe and others. For filled these requirement, radiographer must take an exam to make them expert and trained well to work in this field. There is no advantage using this technique or other technique. So that's why this book was published to make people understand what is radiographic testing truly.

  11. Problems associated with veterinary dental radiography

    International Nuclear Information System (INIS)

    Eisner, E.R.

    1990-01-01

    Veterinarians have been radiographing animal skulls for many years, but sophisticated dentistry was not widely used until the 1970s. Elevated awareness of veterinary dental techniques has led to the need for producing accurate radiographic images of the teeth and periodontal structures. Many problems arise for the clinician who treats small animals who has, before this time, radiographed the skull of dogs and cats solely for the purpose of assessing neoplastic, infectious, or traumatic disease of the mandible, maxilla, or calvarium and now desires to perform dental radiography. This chapter will describe the advantages and disadvantages of some of the more common types of radiographic equipment and supplies, discuss extraoral and intraoral radiographic positioning and technique, identify anatomic landmarks and diagnostic features of intraoral radiography, and offer suggestions concerning the art of using dental radiography in veterinary practice

  12. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  13. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  14. Development of cosmic-ray radiography with nuclear emulsion and its applications

    International Nuclear Information System (INIS)

    Morishima, Kunihiro

    2017-01-01

    We are developing cosmic-ray radiography with nuclear emulsion. Cosmic-ray radiography is non-destructive inspection technology to take image of inner structure of gigantic objects (nuclear reactor, pyramids, volcanoes and so on). We conducted cosmic-ray radiography of Fukushima Daiichi Nuclear Power Plant from 2014 to 2015 and are conducting cosmic-ray radiography of Pyramids at Egypt from 2015. In this paper, technical details and latest results are presented. (author)

  15. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  16. A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Daegoo

    International Nuclear Information System (INIS)

    Jo, Gwang Ho; Kang, Yeopng Han; Kim, Bu Sun

    2008-01-01

    Digital imaging for general radiography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  17. Radiography and bone scintigraphy in bone marrow transplant multiple myeloma patients

    International Nuclear Information System (INIS)

    Aagren, B.; Aspelin, P.

    1997-01-01

    Purpose: To compare conventional radiography and bone scintigraphy in relation to clinical outcome in bone marrow transplant multiple myeloma patients. Material and Methods: A total of 70 radiographies and 70 bone scintigraphies were compared in 35 patients. Results: The skull, the extremities, the iliac and public bones were better assessed with radiography. For new vertebral lesions and for lesions in the ribs and sternum, bone scintigraphy proved superior. For the sacrum, the methods were equal. When bone scintigraphy was used as a complement to radiography, 4% more pathological sites were found. No patient had both a normal radiography and a pathological bone scintigraphy, but 5 patients had both a normal bone scintigraphy and a pathological radiography. The results of the radiological examinations did not always correlate with the clinician's grading of the patient's disease. The radiological examinations had no prognostic value for the 7 patients examined on several occasions. Conclusion: The ability of conventional radiography and bone scintigraphy to disclose myeloma lesions varies, depending on location and size of the lesions. Radiography should remain the primary examination modality also for bone marrow transplant multiple myeloma patients. Bone scintigraphy can severe as a complement for investigating unexplained pain, e.g. caused by lesions in vertebrae or ribs. (orig.)

  18. Digital image intensifier radiography. One year's experience with a Polytron system

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.; Georgi, M.

    1989-01-01

    Since January 1988, digital image intensifier radiography has been used in the Clinic in Mannheim for DSA examinations and also in place of conventional screen/film examinations. Measurements have shown that compared with 100 mm and film/screen formats, digital radiography has poorer spatial resolution, but improved contrast resolution. The most common use of digital radiography was for examinations of the gastrointestinal tract. Using the demonstration of the mucosal fine relief pattern as a criterion of image quality, digital image intensifier radiography was able to achieve this satisfactorily. Comparison with film/screen examinations showed no loss of diagnostic information. Advantages of image intensifier radiography are reduced radiation dose, the possibility of postprocessing and economy. On the basis of 399 examinations, digital image intensifier radiography is now firmly established as part of the daily routine of the Mannheim Clinic. (orig.) [de

  19. Ambulating radiography

    International Nuclear Information System (INIS)

    Magnusson, K.

    1989-01-01

    Strong gamme or X-ray sources are utilized for non-destructive testing of i.e. bridges. The activities involve certain risks of accident that might lead to serious injuries caused by radiation. The National Institute of Radiation Protection has during the laste decade greatly yhe inspection rate in this area. It has today made controls of most enterprieses running ambulating radiography. (O.S.)

  20. High speed motion neutron radiography of two-phase flow

    International Nuclear Information System (INIS)

    Robinson, A.H.; Wang, S.L.

    1983-01-01

    Current research in the area of two-phase flow utilizes a wide variety of sensing devices, but some limitations exist on the information which can be obtained. Neutron radiography is a feasible alternative to ''see'' the two-phase flow. A system to perform neutron radiographic analysis of dynamic events which occur on the order of several milliseconds has been developed at Oregon State University. Two different methods have been used to radiograph the simulated two-phase flow. These are pulsed, or ''flash'' radiography, and high speed movie neutron radiography. The pulsed method serves as a ''snap-shot'' with an exposure time ranging from 10 to 20 milliseconds. In high speed movie radiography, a scintillator is used to convert neutrons into light which is enhanced by an optical intensifier and then photographed by a high speed camera. Both types of radiography utilize the pulsing capability of the OSU TRIGA reactor. The principle difficulty with this type of neutron radiography is the fogging of the image due to the large amount of scattering in the water. This difficulty can be overcome by using thin regions for the two-phase flow or using heavy water instead of light water. The results obtained in this paper demonstrate the feasibility of using neutron radiography to obtain data in two-phase flow situations. Both movies and flash radiographs have been obtained of air bubbles in water and boiling from a heater element. The neutron radiographs of the boiling element show both nucleate boiling and film boiling. (Auth.)

  1. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  2. Development of techniques for furthering the use of isotope radiography

    International Nuclear Information System (INIS)

    Wamorkar, R.R.; Singh, G.; Kalurkar, A.R.; Jagasia, N.S.; Malhotra, H.K.

    1977-01-01

    Isotope radiography techniques in the non-conventional applications such as : (a) hot radiography - a method for examination of radioactive materials, and (b) thin section radiography for inspection of biological specimen and non-metallic specimen are described. Also, a process used for the reproduction of gamma-graphs of welds and castings has been discussed in detail. (author)

  3. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  4. Use of radiography in archaeology

    International Nuclear Information System (INIS)

    Chetin, M.; Ekinci, Sh.; Aksu, M.

    2014-01-01

    Full text : Radiography is a versatile technique with many applications to archaeological and art historical artefacts. It can be used to assess the condition of objects before conservation treatment, to gain insight into materials used and methods of construction and to reveal the secrets of the embalmers art, hidden within mummified remains. X-ray radiography is an invaluable investigative technique that is non-destructive, quick and cost effective. The study described below covers the investigations of the archaeological artefacts in order to determine their corrosion conditions and production histories which are important for restoration, conservation, replica, dating and inventory works

  5. Water calibration measurements for neutron radiography: Application to water content quantification in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M., E-mail: kangm@ornl.gov [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bilheux, H.Z., E-mail: bilheuxhn@ornl.gov [Chemical and Engineering Materials Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Voisin, S. [Computational Sciences and Engineering Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Cheng, C.L.; Perfect, E. [Department of Earth and Planetary Sciences, University of Tennessee, Knoxville, TN (United States); Horita, J. [Department of Geosciences, Texas Tech University, Lubbock, TX (United States); Warren, J.M. [Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2013-04-21

    Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 0.2 cm when the water calibration cells were positioned close to the face of the detector/scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

  6. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  7. Quality comparison of direct digital panoramic radiography and computed radiography panoramic

    Directory of Open Access Journals (Sweden)

    Dariush Goodarzipour

    2013-09-01

    Full Text Available BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels. The first category is defined as computed radiography (CR or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR. Both of these technologies have their own advantages and disadvantages. One of the most important fields in comparison of these systems is their resultant image quality. The purpose of this study was to compare the subjective image quality of DDR and CR digital panoramic system, and to assess the overall density and contrast of their images. METHODS: 200 patients were randomly allocated to two digital systems: Promax [central control digital (CCD] and XC [photostimulable phosphor plates (PSP]. Image quality was evaluated in six regions on a 3-point scale by three oral and maxillofacial radiologists independently. In addition, observers assessed overall density and contrast of each image on a 3-point scale. RESULTS: Using chi-square test, no statistically significant differences were found (P >0.05 in subjective image quality of anatomic structures between the two radiographic systems. But DDR system outperformed CR system in overall density and contrast of the image. P values for both overall density and contrast of the images was less than 0.001. CONCLUSIONS: The subjective image quality of CR and DDR panoramic systems in specified anatomic regions were found statistically comparable in this study. In overall density and contrast of the radiographs, DDR system proved better than CR system.

  8. Radiography of the chest and upper airway

    International Nuclear Information System (INIS)

    Sharko, G.A.; Wilmot, D.M.

    1987-01-01

    The techniques of radiography of the chest in all pediatric-age groups differ only slightly from those used in adult radiography. The technologist's principal challenge, however, relates to optimum handling of the patient with respect to positioning and radiation protection. The hints provided in this chapter should permit the conscientious radiographer to obtain high quality radiographs on all pediatric patients

  9. Radiological protection in equine radiography and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoxall, A.T.

    1977-10-01

    The principles of radiological protection are summarised and consideration is then given to problems, which may confront the equine practitioner, in the fulfillment of these principles during diagnostic radiography of the limbs, head, and spine of the horse. The place of anaesthesia in such procedures is discussed and the special problems associated with therapeutic radiography of the horse are considered.

  10. Evaluation of a Noise Reduction Procedure for Chest Radiography

    Science.gov (United States)

    Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi

    2013-01-01

    Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577

  11. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  12. Establishing rigour in qualitative radiography research

    International Nuclear Information System (INIS)

    Murphy, F.J.; Yielder, J.

    2010-01-01

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  13. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  14. Learning Styles of Radiography Students during Clinical Practice

    Science.gov (United States)

    Ward, L. Patrice

    2009-01-01

    The purpose of this study was to identify and describe the common learning styles of radiography students during clinical practice. Quantitative, descriptive research methodology identified the learning styles of radiography students. A single self-report questionnaire, developed to assess learning styles in clinical practice, was administered…

  15. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  16. Common positioning errors in panoramic radiography: A review

    International Nuclear Information System (INIS)

    Randon, Rafael Henrique Nunes; Pereira, Yamba Carla Lara; Nascimento, Glauce Crivelaro do

    2014-01-01

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  17. Neutron radiography at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pleinert, H.; Lehmann, E.; Hammer, J.

    1994-01-01

    Neutron radiography provides an efficient tool of measurement for many applications in fundamental research as well as in industrial non-destructive testing (NDT). A neutron radiography program has been initiated at the Paul Scherrer Institute and implemented since 1992. From the beginning of 1992 until the end of 1993, a neutron facility has been in operation at the SAPHIR research reactor. Several applications have been tested and programs on two main fields of application have been established, focusing on the study of porous materials, especially concrete and granitic rock. The investigations on concrete and other building materials are carried out in cooperation with the Swiss Federal Institute of Technology in Zurich. The experimental activities are currently carried out at the Atominstitute of the Austrian Universities in Vienna, in the framework of a cooperation program with the Atominstitute. The continuation of the activities on a new radiography facility at the spallation source SINQ is planned at the Paul Scherrer Institute. In the following an overview of the method, of the actual and potential applications of neutron radiography at the Paul Scherrer Institute is given. (author) 6 figs., 1 tab., 3 refs

  18. Clinical Evaluation of a Dual-Side Readout Technique Computed Radiography System in Chest Radiography of Premature Neonates

    International Nuclear Information System (INIS)

    Carlander, A.; Hansson, J.; Soederberg, J.; Steneryd, K.; Baath, M.

    2008-01-01

    Background: Recently, the dual-side readout technique has been introduced in computed radiography, leading to an increase in detective quantum efficiency (DQE) compared with the single-side readout technique. Purpose: To evaluate if the increase in DQE with the dual-side readout technique results in a higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Material and Methods: Twenty-four chest radiographs of premature neonates were collected from both a single-side readout technique system and a double-side readout technique system. The images were processed in the same image-processing station in order for the comparison to be only dependent on the difference in readout technique. Five radiologists rated the fulfillment of four image quality criteria, which were based on important anatomical landmarks. The given ratings were analyzed using visual grading characteristics (VGC) analysis. Results: The VGC analysis showed that the reproduction of the carina with the main bronchi and the thoracic vertebrae behind the heart was better with the dual-side readout technique, whereas no significant difference for the reproduction of the central vessels or the peripheral vessels could be observed. Conclusions: The results indicate that the higher DQE of the dual-side readout technique leads to higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Keywords: Digital radiography; lung; observer performance; pediatrics; thorax

  19. Skin entrance dose for digital and film radiography in Korean dental schools

    International Nuclear Information System (INIS)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol

    2005-01-01

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 μGy for digital radiography and 1,205.0 μGy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  20. Skin entrance dose for digital and film radiography in Korean dental schools

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    2005-12-15

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 {mu}Gy for digital radiography and 1,205.0 {mu}Gy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  1. Algorithm for optimisation of paediatric chest radiography

    International Nuclear Information System (INIS)

    Kostova-Lefterova, D.

    2016-01-01

    The purpose of this work is to assess the current practice and patient doses in paediatric chest radiography in a large university hospital. The X-ray unit is used in the paediatric department for respiratory diseases. Another purpose was to recommend and apply optimized protocols to reduce patient dose while maintaining diagnostic image quality for the x-ray images. The practice of two different radiographers was studied. The results were compared with the existing practice in paediatric chest radiography and the opportunities for optimization were identified in order to reduce patient doses. A methodology was developed for optimization of the x-ray examinations by grouping children in age groups or according to other appropriate indication and creating an algorithm for proper selection of the exposure parameters for each group. The algorithm for the optimisation of paediatric chest radiography reduced patient doses (PKA, organ dose, effective dose) between 1.5 and 6 times for the different age groups, the average glandular dose up to 10 times and the dose for the lung between 2 and 5 times. The resulting X-ray images were of good diagnostic quality. The subjectivity in the choice of exposure parameters was reduced and standardization has been achieved in the work of the radiographers. The role of the radiologist, the medical physicist and radiographer in the process of optimization was shown. It was proven the effect of teamwork in reducing patient doses at keeping adequate image quality. Key words: Chest Radiography. Paediatric Radiography. Optimization. Radiation Exposure. Radiation Protection

  2. Radiation protection and safety in industrial radiography

    International Nuclear Information System (INIS)

    1999-01-01

    The use of ionizing radiation, particularly in medicine and industry, is growing throughout the world, with further expansion likely as technical developments result from research. One of the longest established applications of ionizing radiation is industrial radiography, which uses both X radiation and gamma radiation to investigate the integrity of equipment and structures. Industrial radiography is widespread in almost all Member States. It is indispensable to the quality assurance required in modern engineering practice and features in the work of multinational companies and small businesses alike. Industrial radiography is extremely versatile. The equipment required is relatively inexpensive and simple to operate. It may be highly portable and capable of being operated by a single worker in a wide range of different conditions, such as at remote construction sites, offshore locations and cross-country pipelines as well as in complex fabrication facilities. The associated hazards demand that safe working practices be developed in order to minimize the potential exposure of radiographers and other persons who may be in the vicinity of the work. The use of shielded enclosures (fixed facilities), with effective safety devices, significantly reduces any radiation exposures arising from the work. This Safety Report summarizes good and current state of the art practices in industrial radiography and provides technical advice on radiation protection and safety. It contains information for Regulatory Authorities, operating organizations, workers, equipment manufacturers and client organizations, with the intention of explaining their responsibilities and means to enhance radiation protection and safety in industrial radiography

  3. NDE of ceramic insulator blanks by radiography

    International Nuclear Information System (INIS)

    Sarvanan, S.; Venkatraman, B.; Jayakumar, T.; Baldev Raj

    1996-01-01

    The production of ceramic insulators in electrical industry involves a number of steps, one of which is the green blank. The defects such as voids and crack can be present in the extruded green blank. One of the best non-destructive evaluation (NDE) technique radiography. This paper deals with the development of methodology based on theoretical modeling for the examination of ceramics by high sensitivity radiography. (author)

  4. Basic research for developing the quantitative neutron radiography

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Ikeda, Yasushi; Ohkubo, Kohei; Tasaka, Kanji; Yoneda, Kenji; Fujine, Shigenori.

    1992-01-01

    This investigation concerns the basic research and development on quantitative neutron radiography by using a honeycomb collimator which reduces the effect due to scattered neutrons in objective matter. On the observation of the hydrogenate materials such as metal hydrides, water and hydrocarbons by neutron radiography, scattered neutrons from these objectives make the quantitativeness of the neutron radiographic image lower grade. In order to improve the quantitativeness of the image, a honeycomb collimator, which is a honeycomb structure of neutron absorbing material, was introduced to the conventional neutron radiography system. By setting the neutron-absorbing honeycomb collimator between objective and imaging system, neutrons scattered in the objective were absorbed by the honeycomb material and attenuated before coming to the imaging system, but neutrons which were transmitted the objective sample without any interaction reached the imaging system and formed the image of the sample. As the image by purely transmitted neutrons is intrinsic due to the neutronic character of the sample, the image data give the quantitative information. In the present experiment, aluminum honeycomb which was coated with boron nitride was prepared and used in order to image the standard stepwise samples for the evaluation of the quantitative grade of the newly proposed neutron radiography method. From the comparison between macroscopic total cross section and the attenuation coefficient of the thermal neutron for aluminum, copper and hydrocarbons, it was confirmed that they were fairly consistent each other. It can be concluded that the newly proposed neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improves remarkably the quantitativeness of the neutron radiography technique. (author)

  5. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  6. Space Telecommunications Radio System STRS Cognitive Radio

    Science.gov (United States)

    Briones, Janette C.; Handler, Louis M.

    2013-01-01

    Radios today are evolving from awareness toward cognition. A software defined radio (SDR) provides the most capability for integrating autonomic decision making ability and allows the incremental evolution toward a cognitive radio. This cognitive radio technology will impact NASA space communications in areas such as spectrum utilization, interoperability, network operations, and radio resource management over a wide range of operating conditions. NASAs cognitive radio will build upon the infrastructure being developed by Space Telecommunication Radio System (STRS) SDR technology. This paper explores the feasibility of inserting cognitive capabilities in the NASA STRS architecture and the interfaces between the cognitive engine and the STRS radio. The STRS architecture defines methods that can inform the cognitive engine about the radio environment so that the cognitive engine can learn autonomously from experience, and take appropriate actions to adapt the radio operating characteristics and optimize performance.

  7. Apparatus for proton radiography

    International Nuclear Information System (INIS)

    Martin, R.L.

    1976-01-01

    An apparatus for effecting diagnostic proton radiography of patients in hospitals comprises a source of negative hydrogen ions, a synchrotron for accelerating the negative hydrogen ions to a predetermined energy, a plurality of stations for stripping extraction of a radiography beam of protons, means for sweeping the extracted beam to cover a target, and means for measuring the residual range, residual energy, or percentage transmission of protons that pass through the target. The combination of information identifying the position of the beam with information about particles traversing the subject and the back absorber is performed with the aid of a computer to provide a proton radiograph of the subject. In an alternate embodiment of the invention, a back absorber comprises a plurality of scintillators which are coupled to detectors. 10 claims, 7 drawing figures

  8. Liquid metal flow measurement by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, N.; Ono, A.; Matsubayashi, M.; Tsuruno, A.

    1996-01-01

    Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd 3 ) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.)

  9. Use of VAP3D software for production and manipulation of synthetic radiographies of anthropomorphic models

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Lindeval Fernandes de, E-mail: lindeval@dmat.ufrr.b [Universidade Federal de Roraima (DMAT/UFRR), Boa Vista, RR (Brazil). Dept. de Matematica; Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Vieira, Jose W. [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Universidade de Pernambuco (EPP/UPE), Recife, PE (Brazil). Escola Politecnica de Pernambuco; Lima, Fernando R.A., E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Leal Neto, Viriato [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2011-07-01

    The Grupo de Dosimetria Numerica has developed exposure computational models (ECM) involving a Monte Carlo code and voxel phantoms to simulate various situations of internal and external exposure to ionizing radiation. Most analyses of the produced results are presented in tables and graphics formats. An alternative to this traditional way of analyzing results is to save voxels of Regions of Interest (ROI) of the phantom irradiated with information like the location of the voxel and the energy deposited in it during the simulation. Such information can be saved to a text file and later turned into 3D objects. In this paper the VAP3D software has been used to read text files produced in simulations using the ECM of DEN (Nuclear Energy Dept. - UFPE), converting them into binary files of the type RAW, and visualize them. In order to reflect the radiosensitivity of the organs and tissues suggested by ICRP-60, for conversion of text file to binary, of the energy deposited values are multiplied by the weighting factor of the tissue to which the voxel belongs. The result of the multiplication is normalized to the interval [0, 255]. The files transformed are referred herein as synthetic radiographies. In VAP3D software, it is possible to generate stacks from theses radiographies in transverse, sagittal and coronal directions. In order to illustrate the production of synthetic radiographies, some images are presented in this paper, and dosimetric results are obtained from a variety of ROIs of the phantoms of DEN for radiological exams. (author)

  10. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  11. Digital Radiography of a Drop Tested 9975 Radioactive Materials Packaging

    International Nuclear Information System (INIS)

    Blanton, P.S.

    2001-01-01

    This paper discusses the use of radiography as a tool for evaluating damage to radioactive material packaging subjected to regulatory accident conditions. The Code of Federal Regulations, 10 CFR 71, presents the performance based requirements that must be used in the development (design, fabrication and testing) of a radioactive material packaging. The use of various non-destructive examination techniques in the fabrication of packages is common. One such technique is the use of conventional radiography in the examination of welds. Radiography is conventional in the sense that images are caught one at a time on film stock. Most recently, digital radiography has been used to characterize internal damage to a package subjected to the 30-foot hypothetical accident conditions (HAC) drop. Digital radiography allows for real time evaluation of the item being inspected. This paper presents a summary discussion of the digital radiographic technique and an example of radiographic results of a 9975 package following the HAC 30-foot drop

  12. Non-destructive evaluation utilizing imaging plates for field radiography applications

    International Nuclear Information System (INIS)

    White, Brian S.

    2016-01-01

    The oil and gas industry has utilized film radiography for the evaluation of pipeline welds for many years. The world has evolved, and today people are easily sharing digital images as part of the information revolution. Computed radiography is ready to replace film radiography for portable outdoor use applications. Computed radiography technology adoption has been contingent upon achieving acceptable image quality and getting enough imaging plate use cycles to be profitable. Image quality is dependent upon shot conditions, imaging plate type, reader settings, and scatter control. Likewise, the number of achievable use cycles is dependent upon the imaging plate design for durability and the user's operating environment. This presentation reviews the basic principles of storage phosphor imaging plates. Usage criteria and guidelines for optimum image quality and maximized overall use cycles will be discussed for various imaging plate types. A comparison of film and computed radiography imaging plate technology will be presented.

  13. Report based on fiscal 2000 diagnostic X-ray equipment questionnaire survey. Conditions of radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Mitsuo [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Allied Health Sciences; Matsuura, Takatoshi [Sekishinkai Sayama Hospital, Saitama (Japan); Okuaki, Tomoyuki; Imai, Yoshio; Tsukamoto, Atsuko [Kanto Medical Center NTT EC, Tokyo (Japan); Ide, Toshinori [Kajima Corp., Tokyo (Japan). Kajima Clinic; Shinohara, Fuminori [Nippon Medical School, Kawasaki, Kanagawa (Japan). Second Hospital; Miyazaki, Shigeru [Toho Univ., Tokyo (Japan). Ohashi Hospital

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film (SEF) in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations. (author)

  14. [Report based on fiscal 2000 diagnostic x-ray equipment questionnaire survey(conditions of radiography)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomiyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film(S EF)in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations.

  15. Applications of radio frequency identification systems in the mining industry

    Energy Technology Data Exchange (ETDEWEB)

    Hind, D J [Davis Derby Ltd., Derby (United Kingdom)

    1994-01-01

    Radio Frequency Identification Systems (RFID) are one of the automatic data capture technologies taking over from bar codes and magnetic swipe cards in many applications involving automatic hands free operation in arduous environments. RFID systems are based on the use of miniature radio transponders carrying encoded electronic data that is used to uniquely identify the identity of transponders. The paper reviews the types of system available and compares the various techniques involved in the different systems. The various types of transponder are described including the latest state of the art passive read/write high performance types. The problems involved in designing and certifying a system for use in hazardous areas are described, with particular reference to the problems of inadvertent detonator ignition by radio systems. Applications of RFID systems in the mining industry are described, covering applications both on the surface and underground. 1 ref., 10 figs.

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  17. Flash x-radiography for material motion detection

    International Nuclear Information System (INIS)

    Choate, L.M.; Buckalew, W.H.; Posey, L.D.

    1977-01-01

    A significant part of the experimental program dealing with the behavior of prototypic LMFBR fuel pin bundles under mild to severe power transients is that of the observation of fuel/cladding/coolant motion. The feasibility of using electron beam flash x-radiography as a diagnostic tool for safety test facilities is presently under evaluation. A summary of the objectives and approach of the flash x-radiography program is presented

  18. Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography

    Science.gov (United States)

    Tsuchiya, Yoshinori; Matsubayashi, Masahito; Takeda, Tohoru; Lwin, Thet Thet; Wu, Jin; Yoneyama, Akio; Matsumura, Akira; Hori, Tomiei; Itai, Yuji

    2003-11-01

    Neutron radiography is based on differences in neutron mass attenuation coefficients among the elements and is a non-destructive imaging method. To investigate biomedical applications of neutron radiography, imaging of rabbit VX-2 liver cancer was performed using thermal and cold neutron radiography with a neutron imaging plate. Hepatic vessels and VX-2 tumor were clearly observed by neutron radiography, especially by cold neutron imaging. The image contrast of this modality was better than that of absorption-contrast X-ray radiography.

  19. Radiography Student Participation in Professional Organizations.

    Science.gov (United States)

    Michael, Kimberly; Tran, Xuan; Keller, Shelby; Sayles, Harlan; Custer, Tanya

    2017-09-01

    To gather data on educational program requirements for student membership in a state or national professional society, organization, or association. A 10-question online survey about student involvement in professional societies was emailed to 616 directors of Joint Review Committee on Education in Radiologic Technology (JRCERT)-accredited radiography programs. A total of 219 responses were received, for a 36% response rate. Of these, 89 respondents (41%) answered that their programs require students to join a professional organization. The society respondents most often required (70%) was a state radiography society. Sixty respondents (68%) answered that students join a society at the beginning of the radiography program (from matriculation to 3 months in). Of programs requiring student membership in professional societies, 42 (49%) reported that their students attend the state or national society annual conference; however, participation in activities at the conferences and in the society throughout the year is lower than conference attendance. Some directors stated that although their programs' policies do not allow membership mandates, they encourage students to become members, primarily so that they can access webinars and other educational materials or information related to the profession. Survey data showed that most JRCERT-accredited radiography programs support but do not require student membership in professional organizations. The data reveal that more programs have added those requirements in recent years. Increased student participation could be realized if programs mandated membership and supported it financially. ©2017 American Society of Radiologic Technologists.

  20. The use of radiography for thickness measurement and corrosion monitoring in pipes

    International Nuclear Information System (INIS)

    Edalati, K.; Rastkhah, N.; Kermani, A.; Seiedi, M.; Movafeghi, A.

    2006-01-01

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques

  1. The use of radiography for thickness measurement and corrosion monitoring in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Edalati, K. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)]. E-mail: NDT99@aeoi.org.ir; Rastkhah, N. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Kermani, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Seiedi, M. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Movafeghi, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)

    2006-10-15

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ...

  3. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  4. A study on the scattered dose in portable chest radiography

    International Nuclear Information System (INIS)

    Ahn, Bong Seon; Lee, Hwan Hyung

    2000-01-01

    The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. The average of distance of adjacent patients was 219.1 cm at the ward. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it dose not have influence on the adjacent patient. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment

  5. Compton radiography, 2

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Sera, Koichiro; Fukuda, Hiroshi; Shishido, Fumio; Mishina, Hitoshi.

    1977-01-01

    Compton radiography, a tomographic technic with Compton-scattered rays of a monochromatic gamma ray beam, was feasible of tomographing a chest phantom. The result suggested that the technic could be extended to imaging of the lung and the surrounding structures of the chest wall, mediastinum and liver in Compton tomographic mode. (auth.)

  6. Some malpractices in application of computed radiography

    International Nuclear Information System (INIS)

    Liu Ruihong; Jia Shaotian; Wang Yusheng; Li Baohua; Chen Lin; Wang Zhenguang; Liu Jianxin; Gong Jingyue; Liu Daoyong; Xie Xuesong

    2007-01-01

    Objective: To improve the CR image quality and to promote the digital image standard constitution by analyzing the common problems and malpractices in application of computed radiography. Methods: Phenomenon and reasons of 107 CR junk-films from nine three-'A'-hospitals were analyzed, discussed, recorded, and statistised by 20 radiologists, radiographers and engineers. Results: Among 107 junk films, there are 36 cases (33.64%) of incorrect operations, 29 cases (27.10%) of artifacts in reading and transferring the data of IP, 15 cases (14.02%) of artifacts in IP system, and 13 cases (12.15%) of selection of inappropriate radiographic parameters, and 9 cases (8.41%) of printer-failures, and 5 cases (4.67%) of inappropriate post-processing techniques. By analyzing the reasons of 107 junk films we found that 60.74% were due to less responsibilities and incorrect operations, and 35.51% were due to new problems in CR techniques, and other were due to inappropriate post-processing techniques. Conclusion: Responsibilities, operation regulations, digital image quality standards, studying of new techniques and appropriate use of the post-processing techniques are the key points for improving the CR image quality and the diagnosis level. (authors)

  7. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    Energy Technology Data Exchange (ETDEWEB)

    Walstrom, Peter Lowell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garnett, Robert William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chapman, Catherine A. B [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, Harry Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Otoole, Joseph Alfred [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Barber, Ronald L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gomez, Tony Simon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-28

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

  8. Common positioning errors in panoramic radiography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Randon, Rafael Henrique Nunes [Stomathology and Oral Diagnostic Program, School of Dentistry of Sao Paulo, University of Sao Paulo, Sao Paulo (Brazil); Pereira, Yamba Carla Lara [Biology Dental Buco Graduate Program, School of Dentistry of Piracicaba, University of Campinas, Piracicaba (Brazil); Nascimento, Glauce Crivelaro do [Psychobiology Graduate Program, School of Philosophy, Science and Literature of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto (Brazil)

    2014-03-15

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  9. Digital radiography detectors - A technical overview: Part 1

    International Nuclear Information System (INIS)

    Lanca, Luis; Silva, Augusto

    2009-01-01

    During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided

  10. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  11. The Delphi technique in radiography education research

    International Nuclear Information System (INIS)

    John-Matthews, J.St.; Wallace, M.J.; Robinson, L.

    2017-01-01

    Objectives: To describe and review the Delphi technique as a tool for radiographers engaged in mixed-methods research whereby agreement is required on the proficiencies needed by educational programmes for pre- and post- registration radiographers. This is achieved through a description offering a brief history of the technique. Through a literature search, radiography education research using this technique is identified. A protocol for a research project using the technique is presented. Using this worked example, advantages and disadvantages of the method are explored including sampling of participants, sample size, number of rounds and methods of feedback. Key findings: There are limited examples of the use of the Delphi technique in radiography literature including considerations on how to select experts and panel size. Conclusion: The Delphi technique is a suitable method for establishing collective agreement in the design of radiography educational interventions. Additional research is needed to deepen this evidence-based knowledge. - Highlights: • The Delphi Technique is used to gain collective agreement in forecasting healthcare education priorities. • There is increase of the use of the technique in healthcare education literature. • There are some examples of the technique in radiography education research. • A worked example of this technique is provided to critically evaluate this tool.

  12. Pilot experimental study on continual spectrum thermal neutron in-line phase contrast radiography

    International Nuclear Information System (INIS)

    Tang Bin; Huo Heyong; Wu Yang

    2009-01-01

    The in-line phase contrast radiography is one of phase contrast imaging methods. The neutron in-line phase contrast is developed with X-rays phase contrast radiography. In the paper, the principle of in-line phase contrast is introduced briefly and the experimental result of thermal neutron in-line contrast at SPRR-300 is analysed. It shows that thermal neutron can be used as in-line phase contrast radiography and enhances the edge of some sample in radiography and complements the disadvantage of conventional neutron radiography. (authors)

  13. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  15. Neutron radiography in metallurgy

    International Nuclear Information System (INIS)

    Rant, J.; Ilic, R.

    1977-01-01

    The review surveys microneutronographic and neutron-induced autoradiographic techniques and their applications in metallurgy. A brief survey of applications of neutron radiography as a method of non-destructive testing to some macroscopic problems in metallurgy is included. (author)

  16. Dynamic neutron radiography of a combustion engine

    International Nuclear Information System (INIS)

    Brunner, J.; Hillenbach, A.; Schillinger, B.

    2004-01-01

    Dynamic neutron radiography is a non-destructive testing method, which made big steps in the last years. Depending on the neutron flux, the object and the detector a time resolution down to 50 ms is possible. In the case of repetitive processes the object can be synchronized with the detector and better statistics in the image can be obtained by adding radiographies of the same phase. By delaying the trigger signal a radiography movie can be composed with a time resolution down to 100 μs. A combustion engine is an ideal sample for the explained technique, because the motor block of metal is relatively easy to penetrate, while oil and fuel attenuate the thermal neutron beam much stronger. Various experiments were performed at ILL and PSI. Soon the tomography station ANTARES at FRM-II will be ready for measurements. (author)

  17. Inspection of CF188 composite flight control surfaces with neutron radiography

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Mullin, S.K.

    1996-01-01

    At the Royal Military College of Canada's SLOWPOKE-2 Facility, a neutron radiography facility has been designed and installed using a small (20kWth), pool-type research reactor called the SLOWPOKE-2 (Safe Low Power c(K)ritical Experiment) as the neutron source. Since then, the research has continued along two fronts: developing applications and improving the quality of the neutron beam. The most interesting applications investigated to date has been the inspection of various metal ceramic composites and the inspection of the composite flight control surfaces of some of the CF188 Hornet aircraft. As part of the determination of the integrity of the aircraft, it was decided to inspect an aircraft with the highest flight house using both X- and neutron radiography. The neutron radiography and, to a lesser extent, X-radiography inspections completed at McClellan AFB revealed 93 anomalies. After returning to Canada, the component with the greatest structural significance, namely the right hand rudder from the vertical stabilizer, was removed from the aircraft and put through a rigorous program of numerous NDT inspections, including X-radiography (film and real-time), eddy current, ultrasonics (through transmission and pitch-catch), infrared thermography, and neutron radiography. Therefore, of all the techniques investigated, only through transmission ultrasonics and neutron radiography were able to identify large areas of hydration. However, only neutron radiography could identify the small areas of moisture and hydration. Given the structural significance of the flight control surfaces in modern fighter aircraft, even the smallest amounts of hydration could potentially lead to catastrophic results

  18. Relationship among panoramic radiography findings, biochemical markers of bone turnover and hip bone mineral density in the diagnosis of postmenopausal osteoporosis

    International Nuclear Information System (INIS)

    Johari Khatoonabad, M.; Aghamohammadzade, N.; Taghilu, H.; Esmaeili, F.; Jabbari Khamnei, H.

    2011-01-01

    Recent investigations have shown that panoramic radiography might be a useful tool in the early diagnosis of osteoporosis. In addition, bone turnover biochemical marker might be valuable in predicting osteoporosis and fracture risks in the elderly, especially in post-menopausal women. The aim of the present study was to evaluate the relationship among the radio morphometric indices of the mandible, biochemical markers of the bone turnover and hip bone mineral density in a group of post-menopausal women. Patients and Methods: Evaluations of mandibular cortical width, mandibular cortical index, panoramic index and alveolar crest resorption ration (M/M ration) were carried out on panoramic radiographs of 140 post-menopausal women with an age range of 44-82 years. Hip bone mineral density was measured by dual-energy X-ray absorptiometry method. Bone mineral density values were divided into three groups of normal (T score>-1.0), Osteopenic (T score, -2.5 to -1.0) and Osteoporotic (T score<-2.5). Serum alkaline phosphatase and 25(OH) D3 were measured. Results: A decrease in mandibular cortical width by 1 mm increases the likelihood of osteopenia or osteoporosis up to 40%, having taken into consideration the effect of menopause duration. A 1 mm decrease in mandibular cortical width increased the likelihood of moderate or severe erosion of the lower cortex of the mandible up to 28% by taking age into consideration. The results did not demonstrate a statistically significant relationship between bone turnover markers and mandibular radio morphometric indices. Conclusion: Panoramic radiography gives sufficient information to make an early diagnosis regarding osteoporosis in post-menopausal women. Panoramic radiographs may be valuable in the prevention of osteoporotic fractures in elderly women.

  19. Search for adequate quality standards for neutron radiography of nuclear fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-01-01

    Unlike in other fields of industrial radiography, where standard methods and procedures are used to control the quality of the radiographic image, no such standard exists for neutron radiography of nuclear fuel. To fill that gap it was felt that standardization work ought to be started in that field, too. Accordingly in 1979 an Euratom Neutron Radiography Working Group was constituted, which initiated standardization work in the field of neutron radiography of nuclear fuel. Finding adequate standards for image quality of neutron radiographs and checking the accuracy of dimension measurements from them were given first priority. (Auth.)

  20. Industrial radiography X and Gamma

    International Nuclear Information System (INIS)

    Torres M, Nelson; Torres B, Miguel; Montanez, Juan.

    1986-04-01

    This publication gives a practical orientation on industrial radiography. The first chapters deal with basic facts that are useful for professional work in this field. It comprises topics such as generation of X-rays, equipment being used, radiographic films, sensibility, and the penetrameters used. This publication also describes the most used radiographic techniques and the processing of the radiographic film. It contains practical recommendations on how to obtain a good radiographic inspection. It states the reasons for defects in the radiographies. Two annexes are attached which include tables for the selection of penetrameters according to the ASME and DIN codes as well as the time needed for development and fixing according to the temperature

  1. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  2. Effective dose for patient in multimode panoramic radiography

    International Nuclear Information System (INIS)

    Yasaki, Shiro; Daibo, Motoji

    1999-01-01

    In recent years, multimode panoramic radiography has had various functions, such as the auto exposure function, auto focus function (auto function), TMJ radiography and tomogram radiography functions. The purpose of this study was to estimate the effective dose for patients in each mode of the new multimode panoramic radiography (J. MORITA MFG. CORP. Dental Panorama X-ray Apparatus: Veraview Scope X 600). The absorbed doses in important organs involved in the causation of stochastic effects were measured by a thermoluminescent dosimeter using RANDO phantom. The effective doses were calculated using modified tissue weighting factors recommended by the International Commission on Radiological Protection (ICRP) in 1999. The mean field size over skin in typical panoramic and tomographic examinations was about 3% and 0.4% of the total body surface area of 15000 cm 2 . Assuming that the incidence of skin cancer is proportional to the area of skin exposed to ionizing radiation, the tissue weighting factor of skin can be estimated to be about 0.0003 and 0.00004. The estimate in effective dose was lower (5.3 μSv) in the panoramic auto function mode (an average exposure condition of 69 kV 7 mA) than that (6.5-13.8 μSv) in the linear tomogram modes. Since the linear tomogram mode requires a scout view, such as standard panoramic radiography, the dose in the linear tomogram mode becomes higher than other modes. A percentage of gonad doses in effective doses was negligible. (author)

  3. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available   Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  4. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  5. The technological development of neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Berger, H.

    1977-01-01

    Neutron radiography is a relatively recent technological development in the annals of non-destructive evaluation. It promises to play a role of increasing importance as the technology is further developed. The technique is placed in prospective with regard to other non-destructive evaluation methods in this paper. The history of the development of neutron radiography is traced to the early work of Becker, Bothe and the Joliot-Curies in Europe, and to the work of Chadwick in Great Britain. Details of the experiments which led to the discovery of the neutron by Chadwick in 1932, nuclear properties and energy classifications of neutrons, and the various interactions of neutrons with matter are discussed in detail. A history of neutron radiography is presented which outlines the early experiments by Kallmann and Kuhn; these experiments led to the production of the first neutron radiograph in Germany in 1938. The paper continues with a description of the general techniques that are characteristic of the neutron radiographic process. The breadth and extent of present neutron radiographic technology is discussed as a conclusion of the paper. (author)

  6. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  8. Radiography of osseous lesions of the bovine locomotor system

    International Nuclear Information System (INIS)

    Blond, L.; Beauregard, G.; Mulon, P.Y.

    2006-01-01

    Radiography is the ancillary test of choice for lameness in cattle. Osseous lesions due to osteoporosis, osteitis or osteomyelitis and sequestrae can be visualised. Radiography is the only ancillary examination that provides a thorough investigation of the lesion affecting a bovine presented with a non-weight bearing suspected fracture and limb inflammation associated with soft tissue crepitation. Radiography is the only method to ensure that the fracture is not open. It facilitates follow-up of healing of osseous lesions. The period of time required for immobilisation can be adjusted depending on the type of lesions [it

  9. Industrial radiography in the State of Bahia, Brazil: The health protection of workers

    International Nuclear Information System (INIS)

    Andrade, Ana Emilia Oliveira de

    1997-01-01

    This study aimed to identify the Regulatory and Inspection Authority for actions developed by industrial radiography enterprises in the State of Bahia, Brazil, concerning health protection of workers exposed to ionizing radiation in industry. Institutions which legislate about this matter at international, national and State level were identified. These legislations were analysed according to recommendations by the Basic Safety Standards from the Atomic Energy International Agency. Medical Supervision is proposed as a factor to warrant protection to worker's health. This is a service evaluation study, encompassing results, processes and structural components. Emphasis is given to the process component which investigated the adequacy of which is performed by employees and workers. Five enterprises which provide industrial radiography services in the State of Bahia were identified, employing forty workers on a temporary basis. This study also observed: intense workforce, a complete process of contracting out in the sector; inadequate conditions of work organization (long work journey, night work, lack of days-off schedule); inefficiency of medical services responsible by worker's protection concerning radiation specific risks as well as other occupational risks, unrelated to main activity. There is a legal basis for Authorities actions, although it has not been completely implemented. These findings embased the elaboration of a proposal of a Surveillance Program for the Worker Exposed to Industrial Radiation, which includes the setting of safety standards and monitoring of workers exposed to ionization radiation in the occupational environment, accident prevention in this activity and the specialized health care to those affected by radio accidents. (author)

  10. Evaluation of conventional and digital radiography capacities for distinguishing dental materials on radiograms depending on the present radiopacifying agent.

    Science.gov (United States)

    Antonijević, Djordje; Ilić, Dragan; Medić, Vesna; Dodić, Slobodan; Obradović-Djuriĉić, Kosovka; Rakoĉević, Zoran

    2014-11-01

    The radiopacity of an endodontic material can considerably vary as measured on film and a digital sensor. Digital radiography offers numerous advantages over conventional film-based radiography in dental clinical practice regarding both diagnostic capabilities and postintervention procedures. The aim of this study was to investigate the capacity of conventional and charge-conpled device (CCD) based digital radiography to detect material on radiograph depending on the radio-pacifying agent present in the mate- rial. Experimental cements were formulated by mixing Portland cement with the following radiopacifying agents: zinc oxide (ZnO), zirconium oxide (ZrO2), titanium dioxide (TiO2), barium sulphate (BaSO4), iodoform (CHI3), bismuth oxide (Bi2O3) and ytterbium trifluoride (YbF3). In addition, 5 endodontic materials comprising Endometh- asone, Diaket, N2, Roth 801 and Acroseal were investigated to serve as control. Per three specimens of each material were radiographed alongside an aluminum step wedge on film (Eastman Kodak Company, Rochester, NY) and a CCD-based digital sensor (Trophy Radiologie, Cedex, France). Radiopacity values were calculated by converting the radiographic densities of the specimens expressed as a mean optical densities or mean grey scale values into equivalent thickness of aluminum. Two-way ANOVA detected no significant differences with respect to the imaging system (p > 0.05), but the differences were significant with respect to radiopacifier (p < 0.001) and the interaction of the two factors (p < 0.05). Paired t-test revealed significant differences between the methods used for pure Portland cement, all concentrations of BaSO4 and CHI3, 10% and 20% additions of ZrO2 and Bi2O3 and 10% and 30% additions of YbF3 (p < 0.05). The materials which incorporate CHI3 OR BaSO4 as radiopacifying agents are expected to be significantly more radiopaque on a digital sensor than on film. During clinical practice one should concern to the quality of contrast

  11. Studies on image quality and dose exposure in chest radiography in children

    International Nuclear Information System (INIS)

    Schumacher, R.

    1985-01-01

    Chest radiography accounts for almost 50% of all radiographies in radiological departments for children, thus clearly dominating X-ray performances. The indications for examination in children are frequent infections of the upper airways, congenital cardiac defects, and controls in oncological patients. By contrast, indications for radioscopy of the chest organs which figure greatly in adult age and are often required concurrently with every chest radiography, are rather rare in the patient group of a paediatric X-ray department with their rate of c. 0.5% related to chest radiography. Chest radiographs and phantom radiographs were produced using different techniques and were compared by means of subjective and objective image quality parameters. Concurrently, thermoluminescence dosimetry was used to perform dose measurements of the small gonadal dose occurring in patients in chest radiographies. The study aimed at finding a chest radiography technique appropriate for use in paediatric radiology while considering both image quality parameters and the radiation dose required for producing pictures. (orig./DG) [de

  12. Quantitative neutron radiography using neutron absorbing honeycomb

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Oda, Masahiro; Takahashi, Kenji; Ohkubo, Kohei; Tasaka, Kanji; Tsuruno, Akira; Matsubayashi, Masahito.

    1993-01-01

    This investigation concerns quantitative neutron radiography and computed tomography by using a neutron absorbing honeycomb collimator. By setting the neutron absorbing honeycomb collimator between object and imaging system, neutrons scattered in the object were absorbed by the honeycomb material and eliminated before coming to the imaging system, but the neutrons which were transmitted the object without interaction could reach the imaging system. The image by purely transmitted neutrons gives the quantitative information. Two honeycombs were prepared with coating of boron nitride and gadolinium oxide and evaluated for the quantitative application. The relation between the neutron total cross section and the attenuation coefficient confirmed that they were in a fairly good agreement. Application to quantitative computed tomography was also successfully conducted. The new neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improved remarkably the quantitativeness of the neutron radiography and computed tomography. (author)

  13. Real-time transfer and display of radiography image

    International Nuclear Information System (INIS)

    Liu Ximing; Wu Zhifang; Miao Jicheng

    2000-01-01

    The information process network of cobalt-60 container inspection system is a local area network based on PC. The system requires reliable transfer of radiography image between collection station and process station and the real-time display of radiography image on process station. Due to the very high data acquisition rate, in order to realize the real-time transfer and display of radiography image, 100 M Ethernet technology and network process communication technology are adopted in the system. Windows Sockets is the most common process communication technology up to now. Several kinds of process communication way under Windows Sockets technology are compared and tested. Finally the author realized 1 Mbyte/s' inerrant image transfer and real-time display with blocked datagram transfer technology

  14. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND... Records of the specific license for industrial radiography. Each licensee shall maintain a copy of its...

  15. New developments in radiography. An overview

    International Nuclear Information System (INIS)

    Berger, H.; Orphan, V.

    1983-01-01

    Techniques for radiographic inspection are undergoing change. Changes in X-ray sources include higher voltage and current, pulse techniques, smaller focal spots, portability, ease-of-use, and high reliability. Detector improvements include better films, screens and scintillators, real-time methods, electrostatic methods and solid state detectors. We now use many radiation for radiography (X-rays, gamma rays, neutrons and charged particles) and can process radiographic information to accomplish such things as image enhancement, tomography and digital radiography. In this review, the authors discuss some of these developments, many of which have not been applied - or widely applied in the nuclear industry

  16. Non-destructive testing of rocket fuse by thermal neutron radiography

    International Nuclear Information System (INIS)

    An Fulin; Li Furong

    1999-01-01

    A neutron radiography system in reactor horizontal hole of Tsinghua University was introduced, and its capability of neutron radiography was evaluated by theory and experiment, the non-destructive testing for rocket fuse is successful

  17. Passive ultra high frequency radio frequency identification systems for single-item identification in food supply chains

    Directory of Open Access Journals (Sweden)

    Paolo Barge

    2017-02-01

    Full Text Available In the food industry, composition, size, and shape of items are much less regular than in other commodities sectors. In addition, a wide variety of packaging, composed by different materials, is employed. As material, size and shape of items to which the tag should be attached strongly influence the minimum power requested for tag functioning, performance improvements can be achieved only selecting suitable radio frequency (RF identifiers for the specific combination of food product and packaging. When dealing with logistics units, the dynamic reading of a vast number of tags could originate simultaneous broadcasting of signals (tag-to-tag collisions that could affect reading rates and the overall reliability of the identification procedure. This paper reports the results of an analysis of the reading performance of ultra high frequency radio frequency identification systems for multiple static and dynamic electronic identification of food packed products in controlled conditions. Products were considered when arranged on a logistics pallet. The effects on reading rate of different factors, among which the product type, the gate configuration, the field polarisation, the power output of the RF reader, the interrogation protocol configuration as well as the transit speed, the number of tags and their interactions were statistically analysed and compared.

  18. Irradiation hazards and safety standards for patients in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, B D.P.

    1975-07-01

    The historical developments which have led to a reduction in the hazards or potential hazards to patients in dental radiography are reviewed. Based on a simple risk estimate, the safety of present-day techniques employed in routine dental radiography is assessed. Also included in the review is a description of techniques used and results obtained from the National Radiation Laboratory's (NRL) surveillance programme of patients' exposure to irradiation in dental radiography. The possibilities of and need for achieving further reductions of irradiation are discussed.

  19. Value of postmortem thoracic CT over radiography in imaging of pediatric rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Terence S.; Babyn, Paul S. [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Reyes, Jeanette A.; Chiasson, David A. [The Hospital for Sick Children, Department of Paediatric Laboratory Medicine, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Berdon, Walter E. [Columbia Presbyterian Medical Center, Babies Hospital, Department of Radiology, New York, NY (United States)

    2011-06-15

    Studies have reported that thoracic CT may provide greater sensitivity compared with radiography in detection of pediatric rib fractures and fracture healing. The additional sensitivity afforded by thoracic CT may have medicolegal implications where abuse is suspected. To determine the additional value of postmortem thoracic CT compared with radiography in detecting pediatric rib fractures, and fracture healing, using autopsy findings as a gold standard. We retrospectively reviewed 56 coroner's cases with postmortem radiography and CT thoracic survey. All studies underwent primary interpretation by one or two radiologists. The study radiologist independently reviewed all images from 13 patients with positive findings on radiography, CT or autopsy. Sensitivity and specificity between observers and imaging modalities were compared. Primary interpretation: Fractures were recognized on radiography in 5/12 patients who had fractures found at autopsy, and on CT in 8/12 patients. In total, 29% (24/83) of fractures were reported on radiography, and 51% (52/101) of fractures were reported on CT. Study radiologist: Fractures were recognized on radiography in 7/12 patients who had fractures found at autopsy, and on CT in 11/12 patients. In total, 46% (38/83) of fractures were reported on radiography, and 85% (86/101) of fractures were reported on CT. Postmortem thoracic CT provides greater sensitivity than radiography in detecting pediatric rib fractures, most notably in anterior and posterior fractures. However, the degree of improvement in sensitivity provided by CT might depend on observer experience. (orig.)

  20. Recognition of internal structure of unknown objects with simultaneous neutron and gamma radiography

    International Nuclear Information System (INIS)

    Moghadam, K.K.; Nasseri, M.M.

    2004-01-01

    Generally speaking in customary industrial and medical radiography, there is no tendency to reveal the nature of the samples. Ordinarily, the main objective of taking a radiograph is to show the position and dimension of unknown parts, inside the test object and to determine cracks, defects, etc. Whereas in radiography many important factors such as material cross-sections and build-up factors are also involved. In this paper, by using both neutron and gamma radiography techniques, some mathematical relations were successfully generated, in order to calculate the neutron and gamma total macroscopic cross-sections of some unknown elements in the presence of the other elements. For this work, some test pieces were defined and made of lead, silver, copper, Nickel, tin, graphite and polyethylene. The neutron radiography facility at Tehran Research Reactor (TRR) was used as mixed neutron and gamma radiography source (Proceedings of the Second World Conference on Neutron Radiography, Paris, France, pp. 25-32). On testing of a correction of the above-mentioned generated relations, a new technique of simultaneous neutron and gamma radiography was also investigated

  1. Gamma-radiography techniques applied to quality control of welds in water pipe lines

    International Nuclear Information System (INIS)

    Sanchez, W.; Oki, H.

    1974-01-01

    Non-destructive testing of welds may be done by the gamma-radiography technique, in order to detect the presence or absence of discontinuities and defects in the bulk of deposited metal and near the base metal. Gamma-radiography allows the documentation of the test with a complete inspection record, which is a fact not common in other non-destructive testing methods. In the quality control of longitudinal or transversal welds in water pipe lines, two exposition techniques are used: double wall and panoramic exposition. Three different water pipe lines systems have analysed for weld defects, giving a total of 16,000 gamma-radiographies. The tests were made according to the criteria established by the ASME standard. The principal metallic discontinuites found in the weld were: porosity (32%), lack of penetration (29%), lack of fusion (20%), and slag inclusion (19%). The percentage of gamma-radiographies showing welds without defects was 39% (6168 gamma-radiographies). On the other hand, 53% (8502 gamma-radiographies) showed the presence of acceptable discontinuities and 8% (1330 gamma-radiographies) were rejected according to the ASME standards [pt

  2. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  3. Compton radiography, 2. Clinical significance of Compton radiography of a chest phantom

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, S; Sera, K; Fukuda, H; Shishido, F [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis, Leprosy and Cancer; Mishina, H

    1977-09-01

    Compton radiography, a tomographic technic with Compton-scattered rays of a monochromatic gamma ray beam, was feasible of tomographing a chest phantom. The result suggested that the technic could be extended to imaging of the lung and the surrounding structures of the chest wall, mediastinum and liver in Compton tomographic mode.

  4. Retrograde contrast radiography of the distal portions of the intestinal tract in foals

    International Nuclear Information System (INIS)

    Fischer, A.T.; Yarbrough, T.Y.

    1995-01-01

    A technique for retrograde contrast radiography of the distal portions of the intestinal tract of foals was developed and then performed in 25 foals (1 to 30 days old) with colic. Retrograde contrast radiography was shown to be sensitive (100%) and specific (100%) for evaluating obstruction of the small colon or transverse colon. It was slightly less sensitive (86%) and specific (83%) for evaluation of the entire large colon, particularly in older foals. Retrograde contrast radiography provided increased diagnostic capability, compared with that for noncontrast radiography. Retrograde contrast radiography can provide valuable information when evaluating foals with colic and should be part of the diagnostic evaluation

  5. Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index

    International Nuclear Information System (INIS)

    Peters, Sinead E.; Brennan, Patrick C.

    2002-01-01

    Manufacturers offer exposure indices as a safeguard against overexposure in computed radiography, but the basis for recommended values is unclear. This study establishes an optimum exposure index to be used as a guideline for a specific CR system to minimise radiation exposures for computed mobile chest radiography, and compares this with manufacturer guidelines and current practice. An anthropomorphic phantom was employed to establish the minimum milliamperes consistent with acceptable image quality for mobile chest radiography images. This was found to be 2 mAs. Consecutively, 10 patients were exposed with this optimised milliampere value and 10 patients were exposed with the 3.2 mAs routinely used in the department of the study. Image quality was objectively assessed using anatomical criteria. Retrospective analyses of 717 exposure indices recorded over 2 months from mobile chest examinations were performed. The optimised milliampere value provided a significant reduction of the average exposure index from 1840 to 1570 (p<0.0001). This new ''optimum'' exposure index is substantially lower than manufacturer guidelines of 2000 and significantly lower than exposure indices from the retrospective study (1890). Retrospective data showed a significant increase in exposure indices if the examination was performed out of hours. The data provided by this study emphasise the need for clinicians and personnel to consider establishing their own optimum exposure indices for digital investigations rather than simply accepting manufacturers' guidelines. Such an approach, along with regular monitoring of indices, may result in a substantial reduction in patient exposure. (orig.)

  6. ARABIC PROGRAM ON COT KALA LANGSA STREAMING RADIO SEBAGAI STRATEGI BARU PEMBELAJARAN BAHASA ARAB

    Directory of Open Access Journals (Sweden)

    Dhiauddin Dhiauddin

    2015-06-01

    Full Text Available Learning a language means learn to communicate. The goal of learning Arabic by using communicative approach is to stimulate the student to be able to master both receptive and productive skill. Receptive skills includes listening and reading skill, while productive skills includes speaking and writing skills. The objective of this study is to describe the streaming radio as a strategy in Arabic learning for the student of Arabic Department at Cot Kala Langsa State Islamic Institute. The result at the study shows that the streaming radio strategy gives a good response in conducting the Arabic class. Means that streaming radio can enhance the quality of teaching and learning Arabic at this institute.DOI: 10.15408/a.v2i1.1480

  7. Valve radio and audio repair handbook

    CERN Document Server

    MILLER, CHAS

    2000-01-01

    This book is not only an essential read for every professional working with antique radio and gramophone equipment, but also dealers, collectors and valve technology enthusiasts the world over. The emphasis is firmly on the practicalities of repairing and restoring, so technical content is kept to a minimum, and always explained in a way that can be followed by readers with no background in electronics. Those who have a good grounding in electronics, but wish to learn more about the practical aspects, will benefit from the emphasis given to hands-on repair work, covering mechanical as

  8. Findings and recommendations of the competency based standards project for radiography

    International Nuclear Information System (INIS)

    Egan, Ingrid

    1993-01-01

    In February 1992, the National Office of Overseas Skills Recognition funded a $150,000 research project for the development of Competency Based Standards for the professions of Medical Radiation Science (MRS). The four professions of MRS are now considered to be: Radiography, Radiation Therapy, Nuclear Medicine Science and Sonography. The four national documents have aimed at describing the performances of the MRS practitioner at entry level to the profession. Findings from survey and interviews indicate that the existing structure of the undergraduate courses should be reviewed with emphasis on: problem solving skills, theater radiography, paediatric radiography, image interpretation or radiography pathology as well as venepuncture, if accepted nationally. . 5 refs., 1 tab., 5 figs

  9. MTF analysis of the MURR real-time neutron radiography facility

    International Nuclear Information System (INIS)

    Lindsay, J.T.

    1982-01-01

    In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread function (LSF) to obtain the system MTF. A Gd foil was used for the knife-edge on several neutron converter screens and was imaged by a low-light level ISIT camera. The video signal was then digitized and presented to a PDP-11/05 microcomputer for the numerical calculations

  10. Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Soimakallio, S.; Rytkoenen, H.

    1988-01-01

    Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p < 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema. (orig.)

  11. A method of detector correction for cosmic ray muon radiography

    International Nuclear Information System (INIS)

    Liu Yuanyuan; Zhao Ziran; Chen Zhiqiang; Zhang Li; Wang Zhentian

    2008-01-01

    Cosmic ray muon radiography which has good penetrability and sensitivity to high-Z materials is an effective way for detecting shielded nuclear materials. The problem of data correction is one of the key points of muon radiography technique. Because of the influence of environmental background, environmental yawp and error of detectors, the raw data can not be used directly. If we used the raw data as the usable data to reconstruct without any corrections, it would turn up terrible artifacts. Based on the characteristics of the muon radiography system, aimed at the error of detectors, this paper proposes a method of detector correction. The simulation experiments demonstrate that this method can effectively correct the error produced by detectors. Therefore, we can say that it does a further step to let the technique of cosmic muon radiography into out real life. (authors)

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Bone X-ray (Radiography)? ...

  13. Cold neutron radiography using low power accelerator

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki; Iwasa, Hirokatu

    1993-01-01

    A cold neutron source which can be adopted at a low power accelerator was studied. Time-of-flight radiography using the cold neutron source was performed. It is suggested that time-of-flight cold neutron radiography has possibility to distinguish the materials more clearly than the traditional film method since large contrast differences can be obtained by using digital data of the neutron intensity at different energies from thermal to cold region. Material will be identified at the same time by this method. (author)

  14. Gonadal dose reduction in lumbar spine radiography

    International Nuclear Information System (INIS)

    Moilanen, A.; Kokko, M.L.; Pitkaenen, M.

    1983-01-01

    Different ways to minimize the gonadal dose in lumbar spine radiography have been studied. Two hundred and fifty lumbar spine radiographs were reviewed to assess the clinical need for lateral L5/S1 projection. Modern film/screen combinations and gonadal shielding of externally scattered radiation play a major role in the reduction of the genetic dose. The number of exposures should be minimized. Our results show that two projections, anteroposterior (AP) and lateral, appear to be sufficient in routine radiography of the lumbar spine. (orig.)

  15. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  16. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2011-03-15

    The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. This report was carried out by review of the literatures. Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

  17. Diagnostic approach to reflex sympathetic dystrophy after fracture: radiography or bone scintigraphy?

    International Nuclear Information System (INIS)

    Todorovic-Tirnanic, M.; Obradovic, V.; Han, R.; Goldner, B.; Stankovic, D.; Sekulic, D.; Lazic, T.; Djordjevic, B.

    1995-01-01

    The aim of this paper was to compare the value of bone scintigraphy and radiography in the early diagnosis of post-fracture reflex sympathetic dystrophy (RSD). Thirty-seven adult patients with post-fracture RSD (28 in the first and nine in the second clinical stage of RSD), as well as seven patients with fracture but without RSD (control group), were investigated by radiography and bone scintigraphy. All of them were immobilized (duration of immobilization: 4-22 weeks). In 21 persons three phase bone scintigraphy was performed. The best distinction between the control group and the RSD patients was achieved by delayed bone scintigrams. The sensitivity (97%), positive predictive value (97%) and accuracy (95%) of delayed bone scintigraphy were very high compared to the values for radiography, which were 73%, 90% and 70% respectively. Bone scintigraphy also displayed higher specificity (86%) and negative predictive value (86%) than radiography (57% and 29% respectively). In the first clinical stage the difference between the accuracy of bone scintigraphy (97%) and radiography (63%) was greater than for the whole group. In the second stage of RSD the accuracy of bone scintigraphy (86%) and radiography (81%) was similar. Three-phase bone scintigraphy is not necessary for the diagnosis of post-fracture RSD: it is sufficient to perform delayed bone scintigraphy. It is concluded that bone scintigraphy is to be preferred to radiography for the early diagnosis of post-fracture RSD in the first clinical stage. In the second stage the diagnostic capabilities of bone scintigraphy and radiography are more comparable. (orig.)

  18. Grote Reber, Radio Astronomy Pioneer, Dies

    Science.gov (United States)

    2002-12-01

    Grote Reber, one of the earliest pioneers of radio astronomy, died in Tasmania on December 20, just two days shy of his 91st birthday. Reber was the first person to build a radio telescope dedicated to astronomy, opening up a whole new "window" on the Universe that eventually produced such landmark discoveries as quasars, pulsars and the remnant "afterglow" of the Big Bang. His self- financed experiments laid the foundation for today's advanced radio-astronomy facilities. Grote Reber Grote Reber NRAO/AUI photo "Radio astronomy has changed profoundly our understanding of the Universe and has earned the Nobel Prize for several major contributions. All radio astronomers who have followed him owe Grote Reber a deep debt for his pioneering work," said Dr. Fred Lo, director of the National Radio Astronomy Observatory (NRAO). "Reber was the first to systematically study the sky by observing something other than visible light. This gave astronomy a whole new view of the Universe. The continuing importance of new ways of looking at the Universe is emphasized by this year's Nobel Prizes in physics, which recognized scientists who pioneered X-ray and neutrino observations," Lo added. Reber was a radio engineer and avid amateur "ham" radio operator in Wheaton, Illinois, in the 1930s when he read about Karl Jansky's 1932 discovery of natural radio emissions coming from outer space. As an amateur operator, Reber had won awards and communicated with other amateurs around the world, and later wrote that he had concluded "there were no more worlds to conquer" in radio. Learning of Jansky's discovery gave Reber a whole new challenge that he attacked with vigor. Analyzing the problem as an engineer, Reber concluded that what he needed was a parabolic-dish antenna, something quite uncommon in the 1930s. In 1937, using his own funds, he constructed a 31.4-foot-diameter dish antenna in his back yard. The strange contraption attracted curious attention from his neighbors and became

  19. Problems associated with digital luminescence radiography in the neonate and young infant

    International Nuclear Information System (INIS)

    Arthur, R.J.; Pease, J.N.

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted. (orig.)

  20. Computed radiography imaging plates and associated methods of manufacture

    Science.gov (United States)

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  1. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  2. Recommended practice for the neutron radiography of nuclear fuels

    International Nuclear Information System (INIS)

    Matfield, R.S.

    1983-01-01

    The document is part of a Neutron Radiography Handbook being prepared by a Neutron Radiography Working Party of the European Community. It commences with a description of the information that should be provided by a user of neutron radiography services and then gives recommendations on the equipment to be used. This is followed by two sections on the techniques to be used for detecting discontinuities and the making of measurements on nuclear fuel. This is then followed by recommended safety practices and then sections on film handling, film processing, viewing of radiographs, references, radiographs, storage and records. Recommendations on training and certification are being prepared. It does not include any technical justification for the practices which are recommended. (Auth.)

  3. Compton radiography, 1

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Sera, Koichiro; Fukuda, Hiroshi; Shishido, Fumio; Matsuzawa, Taiju

    1977-01-01

    Tomographic images of an object are obtainable by irradiating it with a collimated beam of monochromatic gamma rays and recording the resultant Compton rays scattered upward at right angles. This is the scattered-ray principle of the formation of a radiation image that differs from the traditional ''silhouette principle'' of radiography, and that bears prospects of stereopsis as well as cross-section tomography. (Evans, J.)

  4. Evaluation of the diagnostic accuracy of four-view radiography and conventional computed tomography analysing sacral and pelvic fractures in dogs.

    Science.gov (United States)

    Stieger-Vanegas, S M; Senthirajah, S K J; Nemanic, S; Baltzer, W; Warnock, J; Bobe, G

    2015-01-01

    The purpose of our study was (1) to determine whether four-view radiography of the pelvis is as reliable and accurate as computed tomography (CT) in diagnosing sacral and pelvic fractures, in addition to coxofemoral and sacroiliac joint subluxation or luxation, and (2) to evaluate the effect of the amount of training in reading diagnostic imaging studies on the accuracy of diagnosing sacral and pelvic fractures in dogs. Sacral and pelvic fractures were created in 11 canine cadavers using a lateral impactor. In all cadavers, frog-legged ventro-dorsal, lateral, right and left ventro-45°-medial to dorsolateral oblique frog leg ("rollover 45-degree view") radiographs and a CT of the pelvis were obtained. Two radiologists, two surgeons and two veterinary students classified fractures using a confidence scale and noted the duration of evaluation for each imaging modality and case. The imaging results were compared to gross dissection. All evaluators required significantly more time to analyse CT images compared to radiographic images. Sacral and pelvic fractures, specifically those of the sacral body, ischiatic table, and the pubic bone, were more accurately diagnosed using CT compared to radiography. Fractures of the acetabulum and iliac body were diagnosed with similar accuracy (at least 86%) using either modality. Computed tomography is a better method for detecting canine sacral and some pelvic fractures compared to radiography. Computed tomography provided an accuracy of close to 100% in persons trained in evaluating CT images.

  5. Reference dose levels for dental panoramic radiography in Gwangju (South Korea)

    International Nuclear Information System (INIS)

    Lee, J. S.; Kim, Y. H.; Yoon, S. J.; Kang, B. C.

    2010-01-01

    This study assessed the reference dose levels for dental panoramic radiography in Gwangju city (South Korea) based on the dose width product (DWP) and compared them with those already established elsewhere. A total of 44 panoramic dental radiographic sets (36 digital and 8 analogue panoramic sets) in 41 dental clinics in Gwangju city were chosen. The third quartile DWP was determined from 429 surface dose measurements of the adult surface dose in panoramic dental radiography. The third quartile DWP for panoramic radiography was 60.1 mGy mm. The proposed DWP reference levels of 60.1 mGy mm were less than or equal to those previously reported in other countries, such as Italy and UK, and acceptable for panoramic radiography in Gwangju (KR). (authors)

  6. The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study.

    Science.gov (United States)

    Menem, R; Barngkgei, I; Beiruti, N; Al Haffar, I; Joury, Easter

    2017-04-01

    The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty patients (aged 18-37), who attended the Faculty of Dentistry at Damascus University for a dental examination, were consecutively screened. Ninety approximal surfaces of posterior permanent teeth without frank cavitations, enamel hypoplasia or restorations were selected and examined using the LFpen (DIAGNOdent pen) and digital bitewing radiography. The reference standard was the visual-tactile inspection, after performing temporary tooth separation, using orthodontic rubber rings, placed for 7 days. The status of included approximal surfaces was recorded as intact/sound, with white/brown spots or cavitated. One trained examiner performed all examinations. There were statistically significant differences in LFpen readings between the three types of approximal surface status (P 16 and 8 at the cavitation and non-cavitation thresholds respectively. The sensitivity, specificity and accuracy (measured by the area under the receiver-operating characteristic curve) were 100, 85 and 95 and 92, 90 and 95% at the cavitation and non-cavitation thresholds respectively. The intra-class correlation coefficient for intra-examiner reliability was 0.95. The diagnostic accuracy of the LFpen was significantly higher than that of digital bitewing radiography (P < 0.001). The LFpen's diagnostic performance was accurate and significantly better than digital bitewing radiography in detecting approximal caries lesions, in posterior permanent teeth.

  7. Optimization of digital radiography techniques for specific application

    International Nuclear Information System (INIS)

    Harara, W.

    2010-12-01

    A low cost digital radiography system (DRS) for testing weld joints and castings in laboratory was assembled. The DRS is composed from X-ray source, scintillator, first surface mirror with Aluminum coating, charged coupled device (CCD) camera and lens. The DRS was used to test flawed carbon steel welded plates with thicknesses up to 12 mm. The comparison between the digital radiographs of the plates weldments and the radiographs of the same plates weldments using medium speed film type had shown that, the detection capability of the weld flaws are nearly identical for the two radiography techniques, while the sensitivity achieved in digital radiography of the plates weldments was one IQI wire less than the sensitivity achieved by conventional radiography of the same plates weldments according to EN 462-1. Further, the DRS was also successfully used to test (100 x 100 x 100) mm Aluminum casting with artificial flaws of varied dimensions and orientations. The resulted digital radiographs of the casting show that, all the flaws had been detected and their dimensions can be measured accurately, this confirm that, The proposed DRS can be used to detect and measure the flaws in the Aluminum and others light metals castings accurately. (author)

  8. Qualitative methods in radiography research: a proposed framework

    International Nuclear Information System (INIS)

    Adams, J.; Smith, T.

    2003-01-01

    Introduction: While radiography is currently developing a research base, which is important in terms of professional development and informing practice and policy issues in the field, the amount of research published by radiographers remains limited. However, a range of qualitative methods offer further opportunities for radiography research. Purpose: This paper briefly introduces a number of key qualitative methods (qualitative interviews, focus groups, observational methods, diary methods and document/text analysis) and sketches one possible framework for future qualitative work in radiography research. The framework focuses upon three areas for study: intra-professional issues; inter-professional issues; and clinical practice, patient and health delivery issues. While the paper outlines broad areas for future focus rather than providing a detailed protocol for how individual pieces of research should be conducted, a few research questions have been chosen and examples of possible qualitative methods required to answer such questions are outlined for each area. Conclusion: Given the challenges and opportunities currently facing the development of a research base within radiography, the outline of key qualitative methods and broad areas suitable for their application is offered as a useful tool for those within the profession looking to embark upon or enhance their research career

  9. Evaluation of the effectiveness of digital radiography in emergency situations

    International Nuclear Information System (INIS)

    Pathi, R.; Langlois, S.

    2002-01-01

    The time differences between digital and conventional radiography for emergency patients were investigated, and clinician satisfaction with the two modalities was compared. Time-motion data was collected daily over 5 weeks for a digital group and a conventional X-ray group. For standardization purposes, only emergency patients requiring chest X-rays were selected for the study. Data were collected from 30 patients in each of the two groups in the time-motion study, and 31 out of 50 Emergency and Intensive Care clinicians responded to the questionnaire. Results were analysed by percentage, and χ 2 analysis was used where appropriate. The time for availability of images to requesting clinicians was 70% less for digital images compared to conventional radiography. The overall satisfaction between digital and conventional radiography was very similar, but most clinicians expressed an opinion that digital radiography offered significant image modification advantages. Copyright (2002) Blackwell Science Pty Ltd

  10. The Radio JOVE Project - Shoestring Radio Astronomy

    Science.gov (United States)

    Thieman, J.; Flagg, R.; Greenman, W.; Higgins, C.; Reyes, F.; Sky, J.

    2010-01-01

    Radio JOVE is an education and outreach project intended to give students and other interested individuals hands-on experience in learning radio astronomy. They can do this through building a radio telescope from a relatively inexpensive kit that includes the parts for a receiver and an antenna as well as software for a computer chart recorder emulator (Radio Skypipe) and other reference materials

  11. Shielding calculations for the design of neutron radiography facility around PARR

    International Nuclear Information System (INIS)

    Ashraf, M.M.; Khan, A.R.

    1989-06-01

    Shielding calculations for neutron radiography facility, proposed to be established around PARR have been carried out using two group diffusion theory and shielding formulae. Gamma radiation penetration calculations have been carried out using simple attenuation methods. The fabrication and installation of the neutron radiography facility would provide the basis for designing a better collimating system and would help establish under water radiography facility for the inspection of highly radioactive materials and components etc. (orig./A.B.)

  12. The emergency department: An appropriate referral rate for radiography

    International Nuclear Information System (INIS)

    Richards, P.J.; Tins, B.; Cherian, R.; Rae, F.; Dharmarajah, R.; Phair, I.C.; McCall, I.

    2002-01-01

    AIM: To evaluate the hypothesis that where there is good clinical practice in an emergency department (ED), there is a low uptake of plain radiography. MATERIALS AND METHODS: Emergency notes and radiography records were reviewed over one week in January 1999, to determine the rate of radiography of first time attenders at the North Staffordshire NHS Trust. The clinical appropriateness of the imaging was assessed by pairs of radiology specialist registrars and casualty physicians. They judged the appropriateness of the imaging by the 1998 Royal College of Radiologists (RCR) guidelines and/or their clinical judgement, by consensus. Where there was no consensus or the data appeared incomplete, the radiology and ED consultant reviewed the notes. RESULTS: A total of 1615 notes were found out of 1643 (98%). Of these, 147 (9%) return attenders were excluded and 32 patients left without being seen. The number of first time attenders was 1436 (87%), of whom 637 (44%) were radiographed; 95% of these radiography examinations were appropriate and 5% were inappropriate. Of the first time attenders who were not radiographed the decision was appropriate in 95% of cases, and inappropriate for 5%, i.e. 5% of those who had no radiography, should have been X-rayed. There were no disagreements between RCR guidelines and the clinical judgements, but in 16% there were no suitable RCR guidelines. Junior doctors were not always able to find the relevant RCR guideline (relevant clinical guideline found in 73% of cases) in the guideline book, compared to the consultants (relevant clinical guideline found in 84% of cases). CONCLUSION: The application of the RCR guidelines is taken as representing good clinical practice in determining when to refer a patient for radiography. Based on this assumption, a referral rate for radiography of 44% of first time attenders was found to be appropriate. This referral rate can be taken as a benchmark. A benchmark is necessary in order to allow departments

  13. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  14. Mobile waste inspection real time radiography system

    International Nuclear Information System (INIS)

    Vigil, J.; Taggart, D.; Betts, S.; Rael, C.; Martinez, F.; Mendez, J.

    1995-01-01

    The 450-KeV Mobile Real Time Radiography System was designed and purchased to inspect containers of radioactive waste produced at Los Alamos National Laboratory (LANL). The Mobile Real Time Radiography System has the capability of inspecting waste containers of various sizes from 5-gal. buckets to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). The fact that this unit is mobile makes it an attractive alternative to the costly road closures associated with moving waste from the waste generator to storage or disposal facilities

  15. Supervision of radiography licensees - using electronic questionnaires

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Aa. [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2005-09-15

    The results from this questionnaire gave a general view of the state of the radiography practices in Sweden, and the questionnaire hopefully contributed to improve the knowledge of these regulations for the licensees. The largest deficiencies were found in the documentation of the radiation protection organisation as well as documentation of quality assurance and operational statistics. The results of the questionnaire constitute a useful basis for selecting companies for future inspections by SSI. Those who has not answered the questionnaire and are working with site radiography can expect a visit in the near future.

  16. Non-destructive test of lock actuator component using neutron radiography technique

    International Nuclear Information System (INIS)

    Juliyanti; Setiawan; Sutiarso

    2012-01-01

    Non-destructive test of lock actuator using neutron radiography technique has been done. The lock actuator is a mechanical system which is controlled by central lock module consisting of electronic circuit which drives the lock actuator works accordingly to open and lock the vehicle door. The non-destructive test using neutron radiography is carried out to identify the type of defect is presence by comparing between the broken and the brand new one. The method used to test the lock actuator component is film method (direct method). The result show that the radiography procedure has complied with the ASTM standard for neutron radiography with background density of 2.2, 7 lines and 3 holes was seen in the sensitivity indicator (SI) and the quite good image quality was obtained. In the brand new actuator is seen that isolator part which separated the coils has melted. By this non-destructive test using neutron radiography technique is able to detect in early stage the type of component's defect inside the lock actuator without to dismantle it. (author)

  17. Radiography with polarised neutrons

    International Nuclear Information System (INIS)

    Schulz, Michael L.

    2010-01-01

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd 1-x Ni x and Ni 3 Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd 1-x Ni x and Ni 3 Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni 3 Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T C on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with different ordering temperatures. This

  18. An application of neutron radiography to archaeology

    International Nuclear Information System (INIS)

    Tugrul, B.

    1990-01-01

    Neutron radiography is more useful for certain materials than are the other radiographic techniques. Some neutrons are attenuated by light materials such as water, hydrocarbons and boron, but penetrate through heavy materials such as steel, lead and uranium. The object must be irradiated by neutrons for neutron radiography. The neutron irradiation can take place in a reactor or with a neutron source. The transfer technique relies on the build-up of radioactivity in a foil due to neutron absorption. In this way an activation image is formed in the foil. For this technique, dysprosium ( 164 Dy) and indium ( 115 In) foils can be used. After this irradiation, foils are transferred to a film in the dark-room, the latent image being formed in the film by decay radiation from the foil. The neutron radiography technique has been applied to a sword together with its sheath (inventory number 83/173) (Tugrul and Erdal 1987); a piece of cloth was visible on the handle of the sword. Sword and sheath had become corroded together. The artefact is from the Ikiztepe excavation near the city of Samsun in north Anatolia and belongs to the Early Bronze Age. First, X-ray radiography showed that the sword had been destroyed in large part and was not suitable for conservation and restoration procedures. Second, neutron radiography was carried out. Dysprosium-164 was used for the transfer method as a foil screen and irradiated in the reactor at 100 kW for half an hour. The dysprosium foil remained against the radiographic (Structurix, D-7) film for approximately three half-lives after the irradiation. The neutron radiograph shows the cloth layer continuing towards the bottom of the sheath. Through the cloth, water would have been introduced to the inside of the sheath and this was the main cause of corrosion to the artefact and so of the sword's destruction. (author)

  19. Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece) and Department of Natural Sciences, Technological Education Institute of Crete, P.O. Box 140, Iraklion 71004 Crete (Greece); Department of Radiology, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece); Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece)

    2009-10-15

    Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional

  20. Utilization and costs of lumbar and full spine radiography by Ontario chiropractors from 1994 to 2001.

    Science.gov (United States)

    Ammendolia, Carlo; Côté, Pierre; Hogg-Johnson, Sheilah; Bombardier, Claire

    2009-07-01

    In Ontario, chiropractors see one-third of patients who seek care for low back pain. Previous studies suggest that chiropractors have high utilization rates of lumbar and full spine radiography. There has been a proliferation of evidence-based guidelines recommending that plain film radiography be used only to assess high-risk patients with low back pain. Evidence for the use of full spine radiography, except for the evaluation of scoliosis is lacking. It is uncertain what impact the growing evidence against their use has had on radiography utilization by Ontario chiropractors. To describe the annual costs and use of lumbar and full spine plain film radiography among Ontario chiropractors between 1994 and 2001. Time-trend analysis of radiography utilization by Ontario chiropractors. Chiropractic claims data submitted to the Ontario Health Insurance Plan or the Workplace Safety & Insurance Board from 1994/1995 to 2000/2001. Change in the annual cost and proportion of claimants receiving lumbar and full spine radiography. Time-trend analysis of chiropractic claims submitted to the Ontario Health Insurance Plan (OHIP) or Workplace Safety & Insurance Board (WSIB) from 1994/1995 to 2000/2001 fiscal years. During the 7-year period, the proportion of OHIP claimants receiving lumbar spine radiography decreased from 4.54% to 3.25% and for full spine radiography from 3.87% to 3.04%. For WSIB claimants, lumbar spine radiography deceased from 6.49% to 3.30% of claimants and full spine radiography from 1.51% to 0.94%. OHIP payments for lumbar spine radiography decreased 12.7% to $562,944, whereas full spine radiography payments decreased 5.3% to $1,071,408. WSIB lumbar and full spine radiography payments decreased 44.2% and 34.3% to $31,202 and $11,713 respectively. Claims data from the two largest third-party payers of chiropractic services in Ontario, suggest that lumbar and full spine radiography, and their associated costs decreased steadily between 1994 and 2001.

  1. Z-petawatt driven ion beam radiography development.

    Energy Technology Data Exchange (ETDEWEB)

    Schollmeier, Marius; Geissel, Matthias; Rambo, Patrick K.; Schwarz, Jens; Sefkow, Adam B.

    2013-09-01

    Laser-driven proton radiography provides electromagnetic field mapping with high spatiotemporal resolution, and has been applied to many laser-driven High Energy Density Physics (HEDP) experiments. Our report addresses key questions about the feasibility of ion radiography at the Z-Accelerator (%E2%80%9CZ%E2%80%9D), concerning laser configuration, hardware, and radiation background. Charged particle tracking revealed that radiography at Z requires GeV scale protons, which is out of reach for existing and near-future laser systems. However, it might be possible to perform proton deflectometry to detect magnetic flux compression in the fringe field region of a magnetized liner inertial fusion experiment. Experiments with the Z-Petawatt laser to enhance proton yield and energy showed an unexpected scaling with target thickness. Full-scale, 3D radiation-hydrodynamics simulations, coupled to fully explicit and kinetic 2D particle-in-cell simulations running for over 10 ps, explain the scaling by a complex interplay of laser prepulse, preplasma, and ps-scale temporal rising edge of the laser.

  2. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik

    ,3 mAs and SID SID of 180 centimetres using a phantom and lithium fluoride thermo luminescence dosimeter (TLD). Dose to risk organs mamma, thyroid and colon are measured at different collimations with one-centimetre steps. TLD results are used to estimate dose reduction for different collimations...... at the conference. Conclusion: Collimation improvement in basic chest radiography can reduce the radiation to female patients at chest x-ray examinations....

  3. Investigation of radiation exposure dosage in dental and panoramic radiography

    International Nuclear Information System (INIS)

    Ishii, Kenichi

    2005-01-01

    Dental radiography and a 10-sheet procedure were conducted at 10 sites in the maxillomandibular anterior teeth and at both sides of the premolar and molar teeth sections with and without a protective apron (total 22 patterns). Experiments, which included a total of five patterns, involving standard ortho-radiography were performed with and without a protective apron, positioning of an apron exclusively on the anterior or the posterior portion of the body and utility of an apron that covered the entire body. Results are as follows: In dental radiography, internal organs included in a bundle demonstrated high radiation exposure, whereas organs excluded from the bundle exhibited low radiation exposure. In organs situated below the thyroid gland, utilization of aprons resulted in lower radiation exposure. In ortho-radiography, radiation exposure was greatest in the parotid gland, followed by the mandibular, sublingual and thyroid glands, respectively. The protective apron resulted in lower radiation exposure at sites situated below the mammary glands; moreover, a protector covering the entire body led to lower radiation exposure in comparison to an apron worn exclusively on the anterior or the posterior aspect of the body. No significant difference was observed in terms of exposure between protective aprons worn on the anterior or the posterior aspect of the body. Furthermore, a protective collar resulted in nearly zero radiation exposure in the thyroid gland. However, a protective collar largely interferes with interpretation of the radiograph; thus, in order to produce interpretable radiographs, protection of the thyroid gland is not possible. In conclusion, radiation exposure dosage can be reduced via utilization of a protective apron positioned below the thyroid gland during dental radiography and below the mammary glands during ortho-radiography. We confirmed evidence indicating that application of a protective apron can reduce patient radiation exposure dosage

  4. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  5. Radio astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Nagnibeda, V.G.

    1981-01-01

    The history of radio astronomical observations at the Astronomical Observatory of Leningrad State University is reviewed. Various facilities are described, and methods and instruments used are discussed. Some results are summarized for radio observations of the sun, including observations of local sources of solar radio emission, the absolute solar radio flux, and radio emission from filaments and prominences.

  6. Internal calibration for equipment AR-2000 radio-TLC imaging scanner

    International Nuclear Information System (INIS)

    Yayan Tahyan; Enny Lestari; Endang Sarmini; Sri Setiyowati

    2013-01-01

    Testing quality system ISO / IEC 17025:2008 requires that equipment and software used in testing have to give good precision and accuracy. Internal calibration is needed to assess the precision and accuracy of the testing device. The equipment AR-2000 radio-TLC Imaging Scanner in the field of nuclear medicine used in radiochemical purity testing. Determined with precision by the coefficient of variation (% CV) and accuracy, while the deviation value based on internal calibration of the retention factor value reading three peaks Carbon-standard sources mentioned that the reference 14. Standard value % CV ≤ 15% and ≤ 3 mm deviation value. Internal calibration results show that the tool AR-2000 radio-TLC Imaging Scanner provides precision values with a mean coefficient of variation (% CV) and accuracy gained 3.1% for the peak value of unity deviation of 1.79 mm, 0.39 mm and the second peak of the peak three 0.55 mm. This suggests that AR-2000 radio tool-TLC Imaging Scanner in good condition. (author)

  7. Applications of radio frequency identification systems in the mining industry

    Energy Technology Data Exchange (ETDEWEB)

    Hind, D J [Davis Derby Ltd., Derby (United Kingdom)

    1995-07-01

    Radio Frequency Identification Systems (RFID) are one of the automatic data capture technologies taking over from bar codes and magnetic swipe cards in many applications involving automatic hands free operation in arduous environments. RFID systems are based on the use of miniature radio transponders carrying encoded electronic data that is used to uniquely identify the identity of transponders. This paper reviews the types of system available and compares the various techniques involved in the different systems. The various types of transponder are described including the latest state of the art passive read/write high performance types. A review of the history of RFID systems in the mining industry is also given in the paper. The problems involved in designing and certifying a system for use in hazardous areas are also described, with particular reference to the problems of inadvertent detonator ignition by radio systems. Applications of RFID systems in the mining industry are described in considerable detail, covering applications both on the surface and underground. 1 ref., 12 figs., 1 tab.

  8. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  9. Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography

    International Nuclear Information System (INIS)

    Shimamoto, Kazuhiro; Ikeda, Mitsuru; Satake, Hiroko; Ishigaki, Satoko; Sawaki, Akiko; Ishigaki, Takeo

    2002-01-01

    Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024 x 1536 x 8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For ''mass'' depiction, interobserver agreement using CR was significantly lower than when using screen-film (p<0.05). There was no significant difference in the kappa value for detecting ''microcalcification''; however, the performance score of ''microcalcification'' on CR hard-copy was significantly lower than on the other three viewing methods (p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms. (orig.)

  10. Radiation protection in technical radiography

    International Nuclear Information System (INIS)

    Thiele, H.

    1980-01-01

    In on-site inspections, e.g. double-plate radiography of circumferential pipe welds Ir-192 is most frequently used. Methods, controlled area, possible personnel doses, and radiation protection measures for the inspection and construction personnel are briefly discussed. (HP) [de

  11. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  12. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  13. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  14. Neutron radiography in Brazil

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1983-01-01

    Neutron radiography studies being carried out in reactor centres in Brazil are discussed. These research projects are under way using the 5 MW swimming pool reactor at the Institute of Energy and Nuclear Research (IPEN) in Sao Paulo and the Argonaut reactor at the Institute of Nuclear Engineering (IEN) in Rio de Janeiro. (Auth.)

  15. Low cost automatic cable winder for industrial radiography projector

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Abdul Nassir Ibrahim; Shaharudin Sayuti; Glam Hadzir Patai Mohamad; Masrol Nizam Salleh; Arshad Yasin; Nur Aira Abdul Rahman

    2009-04-01

    Radiography is a well-established technique that is widely used to detect internal flaws in welds, castings and to check for misconstruction in assemblies. In general it is to verify weld quality in engineering structures such as the fabrication of pressure vessels, pipelines and storage tanks. It can be used on all metals, from light metals such as aluminium to dense metals such as lead. One of the techniques is industrial radiography projector. Industrial radiography projector is used to store radioactive materials when it is not required to expose the material under test. The projector will come together with a guide tube and control unit (cable winder and drive cable). When the source is to be used to radiograph an item, the cable winder will wind-out the source from projector to the desired location through a guide tube. Upon completion of the work the source will be retracted back into its safe shielded position in this projector. In common procedure, the operator has to be close to the exposures projector while wind-out or wind-in the source from and into the projector. This made the radiography operator receive the highest exposure among the radiation operator and this agreed by IAEA. This paper describes a winder cable that can be used to guide the movement of radiography source out of and into the projector that can be controlled by a remote control system. The system comprises of a gear, reversible motor and low frequency automatic controller. This system is powered by DC chargeable battery. (author)

  16. Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

    Science.gov (United States)

    Tanaka, Rie

    2016-07-01

    Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.

  17. Reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications

    Directory of Open Access Journals (Sweden)

    Vilson Lacerda Brasileiro Junior

    2014-02-01

    Full Text Available Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57% patients. Such individuals presented with a total of 29 (41.43% carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50 of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001 was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.

  18. The quality assessment of radial and tangential neutron radiography beamlines of TRR

    International Nuclear Information System (INIS)

    Dastjerdi, M.H. Choopan; Movafeghi, A.; Khalafi, H.; Kasesaz, Y.

    2017-01-01

    To achieve a quality neutron radiographic image in a relatively short exposure time, the neutron radiography beam must be of good quality and relatively high neutron flux. Characterization of a neutron radiography beam, such as determination of the image quality and the neutron flux, is vital for producing quality radiographic images and also provides a means to compare the quality of different neutron radiography facilities. This paper provides a characterization of the radial and tangential neutron radiography beamlines at the Tehran research reactor. This work includes determination of the facilities category according to the American Society for Testing and Materials (ASTM) standards, and also uses the gold foils to determine the neutron beam flux. The radial neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. The tangential beam is a Category IV neutron radiography facility. Gold foil activation experiments show that the measured neutron flux for radial beamline with length-to-diameter ratio (L/D) =150 is 6.1× 10 6 n cm −2 s −1 and for tangential beamline with (L/D)=115 is 2.4× 10 4 n cm −2 s −1 .

  19. Immersion technique in soft tissue radiography of the hands

    International Nuclear Information System (INIS)

    Maekelae, P.; Haaslahti, J.O.

    1978-01-01

    Soft tissue radiography of hands using the technique of mammary radiography and immersion in a 2.5 cm layer of 1 : 1 water-ethanol solution is evaluated. Using immersion the average background density decreases with a factor of about 2.5 : 1, with little deterioration in resolution (MTF). The immersion procedure makes the demonstration and evaluation of soft tisse swelling and periarticular oedema easier. (Auth.)

  20. The Audiocast Diaries: Reflections on Radio and Podcasting for Delivery of Educational Soap Operas

    Science.gov (United States)

    Elliott, Wendy

    2006-01-01

    While studying Gender Issues in Distance Education at Athabasca University, the author has read about nomadic Fulbe women in Nigeria who learned by radio. She became inspired to explore the idea of serial drama as education. She began searching the Internet for ideas. She discovered a striking example of entertainment-education--an educational…

  1. Radiography of Co-60 in the lead cube castings

    International Nuclear Information System (INIS)

    Djoli Soembogo; Harun Al Rasyid R; Namad Sianta

    2016-01-01

    Radiography Co-60 on Carbon steel or Stainless steel has been widely applied, but for metal Lead has not yet been applied and has not yet widely known. Lead has a greater density than Carbon steel or Stainless steel and could muffle gamma radiation so it takes a longer exposure time. The result of its film radiography are also not as good as compared to radiography applications on carbon steel or Stainless steel. The study also applied digital radiography using isotope Co-60 sources and used Epson V700 scanner positive film for digitization results of conventional radiographic films. These radiographs using film AGFA D7 to get the contrast medium, medium sensitivity and good image quality. The purpose of radiography Co-60 on the cube castings Lead is to find indications of defective castings cube Lead and digitizing the results using conventional radiographic film with a positive film media scanner to process the data transfer and storage of digital data. Radiographic testing has been carried out using the isotope Co-60 on metal castings Lead with a single thickness of a single shadow method using positive film scanner media and isotope Co-60 with disabilities observation parameter Lead metal castings on radiographic film. Co-60 radiation time exposure is 3,500 hours for the thickness of the metal cube castings Lead 100 mm with the activity of 29 Ci and perpendicular SFD of 840 mm. Radiographic testing on metal cube castings Lead by the method of a single thickness of single image defects produce a parameter indicative for a cube of metal castings Lead of porosity level 2. The density mean of radiographic film was 2.051 and 2.046 for 5 minutes in a developer solution. The result of scanning positive film is in the form of digital radiography which allows for the transfer of digital data or computerized storage of digital data. This status is still within limits acceptable under the standards referred. (author)

  2. Non destructive testing and neutron radiography in 1994

    International Nuclear Information System (INIS)

    Bayon, G.

    1994-01-01

    Neutron radiography has been considered for a long time as a promising technique; however it plays a minor part in the world of non destructive testing today, due to the lack of suitable neutron sources and lack of new industrial applications. This paper reviews the present status of neutron sources, neutron radiography activities, especially in France (such as the neutron-capture-issued secondary radiation spectrometry), in nuclear, aerospace, aeronautical and metallurgical sectors, and the last applications of neutron dynamic imaging. 9 refs

  3. Detectability of the mediastinal lines : comparison of conventional film-screen radiography and digital radiography

    International Nuclear Information System (INIS)

    Shin, Hye Young; Park, Kyung Joo; Kang, Doo Kyung; Lee, Kang Lai; Han, Chaing Jin; Suh, Jung Ho

    1998-01-01

    Using dynamic range compression (DRC) processing, this study compared the detectability of mediastinal lines by conventional film screen radiography (FS) and by storage phosphor digital radiography (DR). We selected 200 normal consecutive chest radiographs (100 FS, 100 DR); dynamic range compression was applied to DR processing and moving grids were used in both systems. Seven mediastinal lines (left paraspinal, right paraspinal, azygoesophageal, left para-aortic, posterio junctional, anterior junctional and right paratracheal) were scored from 0 point to 3 point (0: not visible, 1 : suspiciously visible, 2 : visible, but not clear, 3: clearly visible) according to visibility and sharpness, as agreed by a radiologist and a resident. The differences between the two modalities were compared and analyzed by chi-square test. DR processed with DRC visualizes mediastinal lines more frequently and clearly than conventional FS, and is therefore thought to be useful for the evaluation of mediastinal diseases. (author). 14 refs., 2 tabs., 2 figs

  4. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition); Seguridad radiologica en la radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-12-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  5. Research Notes ~ The Audiocast Diaries: Reflections on radio and podcasting for delivery of educational soap operas

    Directory of Open Access Journals (Sweden)

    Wendy Elliott

    2006-12-01

    Full Text Available March 24, 2005: While studying Gender Issues in Distance Education at Athabasca University, I read about the nomadic Fulbe women in Nigeria who learned by radio. I could understand their concerns with uninspired educational radio programs that did “not take into consideration the rhythm of . . . [their] lives” (Usman, 2001, p. 98. There was one tiny reference to a drama series, but as a scriptwriter and a woman interested in the power of storytelling as education, I was intrigued. The idea of serial drama as education was planted in my mind...

  6. Comparison of the image quality of digital radiography system and film screen system - Radiologist' rating of the visibility of normal anatomic - Structures in chest PA, Skull radiograph and K. U. B

    International Nuclear Information System (INIS)

    Song, Kounn Sik; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1987-01-01

    Digital image acquisition and display is widely used in computed tomography, ultrasonography, digital subtraction angiography, nuclear medicine and magnetic resonance image. But most of the radiological examinations performed in radiology department are made by using conventional system. The development of the digital radiography system is essential if totally digitized radiology department is desired. The advantages of digitizing the radiographic information are usually discussed in terms of PACS (picture archiving and communication system), furthermore there are many other advantages such as contrast modification, spatial filtering subtraction and superimposition of the images through the image processing by computer. Currently several approaches are under development or in clinical use, the most promising approach is the use of imaging plate composed of photostimulate phosphors such as barium fluorohalide crystal read with a He-Ne laser to produce digital radiographic images. Another promising approach is scan projection radiography. The authors performed the clinical study of comparing the image qualities of digital radiography system using scanning laser luminescence (FCR) and conventional film-screen system in chest PA, skull radiography and K. U. B. in terms of the visibility of the normal anatomic structure rating those (qualities) on a scale of 0 to 3 and obtained the following results. Normal contrast digital images are comparable to conventional film-screen images, but the images of high frequency enhancement is far superior to conventional film-screen especially in peripherally located structures such as skin, subcutaneous fat, musculoskeletal systems, nasal bone, inner and outer table of the skull including the diploic space, paranasal sinuses, nasopharynx and larynx, trachea and main bronchi, mediastinal structures, retrocardiac and subphrenic vascular markings. Another promising aspects of digital radiography system is its wide exposure latitude and

  7. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  8. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    Energy Technology Data Exchange (ETDEWEB)

    Radebe, M.J.; De Beer, F.C. [Necsa - South African Nuclear Energy Corporation Limited, P. O.Box 582, Pretoria, 0001 (South Africa)

    2008-07-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  9. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    International Nuclear Information System (INIS)

    Radebe, M.J.; De Beer, F.C.

    2008-01-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  10. Transmission and archiving of digitalised radiography

    International Nuclear Information System (INIS)

    Zscherpel, U.; Rose, P.; Kaestner, R.; Mayer, R.; Heinrich, W.; Petesch, M.

    1995-01-01

    The 'TRENDT' research project is concerned with the transmission and archiving of digitalised radiography and with the application of wide band transmission networks in nondestructive material testing. (orig./HP) [de

  11. The profile of indications for radiography in the Neonatal Intensive ...

    African Journals Online (AJOL)

    Introduction. Radiography is a key diagnostic tool in paediatric care. A pro-active approach (including the use of radiography) is required to ensure e.ective management of these patients. Taking into account the widely documented harmful e.ects of ionising radiation and the small organ masses of neonates, the number of ...

  12. Neutron radiography and other NDE tests of main rotor helicopter blades

    CSIR Research Space (South Africa)

    De Beer, FC

    2004-10-01

    Full Text Available leading to aircraft structural failures, are addressed by various NDE techniques. In a combined investigation by means of visual inspection, X-ray radiography and shearography on helicopter main rotor blades, neutron radiography (NRad) at SAFARI-1 research...

  13. Magnifying lens for 800 MeV proton radiography

    International Nuclear Information System (INIS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-01-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  14. Digital contrast subtraction radiography for proximal caries diagnosis

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Yoon, Suk Ja

    2002-01-01

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  15. Evaluation of radiography careers information on the Internet

    International Nuclear Information System (INIS)

    Boxall, Amy; Holmes, Ken

    2004-01-01

    The purpose of this paper was to investigate whether information about radiography careers that was placed on the Internet was accessible, accurate, understandable, comprehensive, abundant and attractive to a sample of school children. Additionally this paper investigated whether the sample of school children had access to the Internet and whether they knew how to use it. A self-administered questionnaire was used to assess views on the radiography information, Internet access and knowledge of how to use the Internet. Questionnaire data were then analysed and the Websites were ranked. Thirty-three Websites were evaluated; these gave varying qualities of information with questionnaire scores ranging from 188 to 76. This investigation showed that there are many Websites available about radiography as a career. The site that performed most successfully overall in this evaluation was the NHS Careers Website. This site was ranked highest for the design section but the University of Salford's Website performed top for content

  16. Dose audit for patients undergoing two common radiography examinations with digital radiology systems

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331

  17. Evaluation of conventional and digital radiography capacities for distinguishing dental materials on radiograms depending on the present radiopacifying agent

    Directory of Open Access Journals (Sweden)

    Antonijević Đorđe

    2014-01-01

    Full Text Available Bacgroun/Aim. The radiopacity of an endodontic material can considerably vary as measured on film and a digital sensor. Digital radiography offers numerous advantages over convential film-based radiography in dental clinical practice regarding both diagnostic capabilities and postintervention procedures. The aim of this study was to investigate the capacity of conventional and charge-conpled device (CCD based digital radiography to detect material on radiograph depending on the radio-pacifying agent present in the material. Methods. Experimental cements were formulated by mixing Portland cement with the following radiopacifying agents: zinc oxide (ZnO, zirconium oxide (ZrO2, titanium dioxide (TiO2, barium sulphate (BaSO4, iodoform (CHI3, bismuth oxide (Bi2O3 and ytterbium trifluoride (YbF3. In addition, 5 endodontic materials comprising Endomethasone®, Diaket®, N2®, Roth 801® and Acroseal® were investigated to serve as control. Per three specimens of each material were radiographed alongside an aluminum step wedge on film (Eastman Kodak Company®, Rochester, NY and a CCD-based digital sensor (Trophy Radiologie®, Cedex, France. Radiopacity values were calculated by converting the radiographic densities of the specimens expressed as a mean optical densities or mean grey scale values into equivalent thickness of aluminum. Results. Twoway ANOVA detected no significant differences with respect to the imaging system (p > 0.05, but the differences were significant with respect to radiopacifier (p < 0.001 and the interaction of the two factors (p < 0.05. Paired ttest revealed significant differences between the methods used for pure Portland cement, all concentrations of BaSO4 and CHI3, 10% and 20% additions of ZrO2 and Bi2O3 and 10% and 30% addition of YbF3 (p < 0.05. Conclusion. The materials which incorporate CHI3 or BaSO4 as radiopacifying agents are expected to be significantly more radiopaque on a digital sensor than on film. During clinical

  18. Deflection evaluation using time-resolved radiography

    International Nuclear Information System (INIS)

    Fry, D.A.; Lucero, J.P.

    1990-01-01

    Time-resolved radiography is the creation of an x-ray image for which both the start-exposure and stop-exposure times are known with respect to the event under study. The combination of image and timing are used to derive information about the event. The authors have applied time-resolved radiography to evaluate motions of explosive-driven events. In the particular application discussed in this paper, the author's intent is to measure maximum deflections of the components involved. Exposures are made during the time just before to just after the event of interest occurs. A smear or blur of motion out to its furthest extent is recorded on the image. Comparison of the dynamic images with static images allows deflection measurements to be made

  19. Radio stars

    International Nuclear Information System (INIS)

    Hjellming, R.M.

    1976-01-01

    Any discussion of the radio emission from stars should begin by emphasizing certain unique problems. First of all, one must clarify a semantic confusion introduced into radio astronomy in the late 1950's when most new radio sources were described as radio stars. All of these early 'radio stars' were eventually identified with other galactic and extra-galactic objects. The study of true radio stars, where the radio emission is produced in the atmosphere of a star, began only in the 1960's. Most of the work on the subject has, in fact, been carried out in only the last few years. Because the real information about radio stars is quite new, it is not surprising that major aspects of the subject are not at all understood. For this reason this paper is organized mainly around three questions: what is the available observational information; what physical processes seem to be involved; and what working hypotheses look potentially fruitful. (Auth.)

  20. Proton Radiography for the Diagnostics of a Dense Plasma

    Science.gov (United States)

    Barminova, H. Y.

    2017-12-01

    The possibility of using high-energy proton radiography for dense plasma diagnostics is discussed. The designed telescopic ion optical system for a proton radiography installation with a 1 GeV beam is presented. The schematic diagram of the proton microscope is given. It is shown that the estimate of spatial resolution for the installation obtained with consideration of chromatic aberrations of magnetic quadrupole lenses is limited from below.

  1. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  2. Using Periapical Radiography to Differentiate Periapical Granuloma and Radicular Cysts

    Directory of Open Access Journals (Sweden)

    Farhadi

    2016-06-01

    Full Text Available Background The distinction between radicular cysts and apical granulomas is important in treatment decision. Objectives The current study aimed to differentiate these two lesions based on radiography images. Patients and Methods The material consisted of 138 radiographs obtained using Kodak E -speed, in patients aged 29 to 47, divided into two groups: 109 granulomas and 29 radicular cysts. Size of radiography images was measured; the tooth then was extracted and examined in pathologist lab. The results were analyzed by SPSS.15 and ROC curve was created to find cut-off point to differentiate periapical granuloma and radicular cysts. Results Average size of radiography in periapical granuloma was 7.4 mm and for a radicular cyst was 11.1 mm. Cut-off point was 8.2 mm and the area under curve (AUC was 0.63. Also, the tests were 83% sensitive and 79% specific. Conclusions Based on 8.2 mm cut-off point could differentiate 83% periapical granulomas and 79% radicular cysts from radiography images.

  3. The use of portable shields in industrial radiography

    International Nuclear Information System (INIS)

    Oliveira e Silva, J.A. de.

    1988-01-01

    This paper shows techniques actually used to reduce radiations exposure taxes during examinations execution by gamma radiography in regions of high population density. A portable equipment of radiation shield for using in exams by gamma radiography in pipelines, that is an adjustable device in an object body that will be examined, joining a measured collimator and a shield geometrically arranged so that the radiation restrict to impress the radiographic film used in examination without reaching people, objects or self-movings injurious that are nearness. (C.M.) [pt

  4. High resolution radiography of ambers with pixel detectors

    Czech Academy of Sciences Publication Activity Database

    Dammer, J.; Weyda, F.; Beneš, J.; Sopko, V.; Jandejsek, I.; Pflegerová, Jitka

    2013-01-01

    Roč. 8, č. 3 (2013), C03024 ISSN 1748-0221. [Conference: International Workshop on Radiation Imaging Detectors /14./. Figueira da Foz, 01.07.2012-05.07.2012] Grant - others:GA ČR(CZ) GA103/09/2101; GA Mšk(CZ) LA08032 Program:GA; LA Institutional support: RVO:60077344 Keywords : X-ray detectors * Inspection with x-rays * X-ray radiography and digital radiography (DR) Subject RIV: EA - Cell Biology Impact factor: 1.526, year: 2013 http://iopscience.iop.org/1748-0221/8/03/C03024/

  5. The application and development of radiography technology based on x-ray

    Science.gov (United States)

    Chen, Hao; Xu, Zhou; Li, Ming

    2009-07-01

    Modern Radiography technology was combined with radiation physics and modern imaging processing, which was an important branch of information obtainment and processing. We can get the inside information of the object, by the X ray's attenuation when the ray penetrated the object, and depending on the computer's fast processing, we can see the slice imaging of the object. Computerized Tomography, Computerized Laminography, and Digital Radiography were important parts in Radiography. The institute of applied electronics, CAEP in the research of intense radiation had developed several advanced radiation sources and some advanced radiography imaging systems, for example, S-band small spot linear accelerator, full solid state modulator, C-band linear accelerator, high energy Tera-hertz radiation source and CT technology based on cone beam, DR technology, CL Technology etc. Such imaging systems had been applied in industrial NDT/NDE, security check, medical diagnosis, petroleum and gas pipeline inspection system etc.

  6. Quality assessment of orthodontic radiography in children.

    Science.gov (United States)

    Pakbaznejad Esmaeili, Elmira; Ekholm, Marja; Haukka, Jari; Waltimo-Sirén, Janna

    2016-02-01

    Numbers of dental panoramic tomographs (DPTs) and lateral cephalometric radiographs (LCRs) outweigh other radiographic examinations in 7- to 12-year-old Finns. Orthodontists and general practitioners (GPs) involved in orthodontics hold therefore the highest responsibility of the exposure of children to ionising radiation with its risks. Against this background, lack of reports on the quality of orthodontic radiography is surprising. The purpose of our study was to shed some light and draw the awareness of the orthodontic community on the subject by analyzing the quality of orthodontic radiography in Oral Healthcare Department of City of Helsinki, in the capital of Finland. We analyzed randomly selected 241 patient files with DPTs and 118 patient files with LCRs of 7- to 12-year-olds for the indications of radiography, quality of referrals, status of interpretation, and number of failed radiographs. The majority of DPTs (95%) and all LCRs had been ordered for orthodontic reasons. Of the DPTs, 60% were ordered by GPs, and of the LCRs, 64% by orthodontists. The referrals were adequate for most DPTs (78%) and LCRs (73%), orthodontists being responsible for the majority of inadequate referrals. Of the DPTs, 80% had been interpreted. Of the LCRs, 65% lacked interpretation, but 67% had been analysed cephalometrically. Failed radiographs, leading to repeated exposure, were found in 2-3%. The quality assessment revealed that orthodontic radiography may not completely fulfill the criteria of good practice. Our results stress further need of continuing education in radiation protection among both orthodontists and GPs involved in orthodontics. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  7. Safety procedures for radiography works

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Work preparation: before exposure, during exposure, after work completion. Radiographic work at the open site: types of open sites, establishment of radiographic boundary, storage of radiographic equipment at sites. Safety procedures for radiography works; radiographic works in exposure room

  8. Radiography shielding

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.

    1985-11-27

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume.

  9. Radiography shielding

    International Nuclear Information System (INIS)

    Redmayne, I.

    1985-01-01

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume. (author)

  10. Careers and destinations of radiography students from the University of Hertfordshire

    Energy Technology Data Exchange (ETDEWEB)

    Vosper, M.R. [School of Paramedic Sciences, Physiotherapy and Radiography, Faculty of Health and Human Sciences, University of Hertfordshire, College Lane, Hatfield, Hertfordshire AL10 9AB (United Kingdom); Price, R.C. [School of Paramedic Sciences, Physiotherapy and Radiography, Faculty of Health and Human Sciences, University of Hertfordshire, College Lane, Hatfield, Hertfordshire AL10 9AB (United Kingdom)]. E-mail: r.c.price@herts.ac.uk; Ashmore, L.A. [School of Paramedic Sciences, Physiotherapy and Radiography, Faculty of Health and Human Sciences, University of Hertfordshire, College Lane, Hatfield, Hertfordshire AL10 9AB (United Kingdom)

    2005-05-01

    Purpose: Vacancy rates have increased for diagnostic and therapeutic radiography over the past two years with the three-month rates standing at 5.5% and 8.8% in March 2002 for both disciplines. Anecdotal evidence suggests retention of radiographers is poor but there has been little empirical research into why this is the case. This study, conducted by the University of Hertfordshire, investigates the career progression of past students. Methods: A questionnaire was sent to all graduates for whom a contact address was available (n = 303). The questionnaire included questions seeking information on current employment and grading, any problems or barriers encountered in pursuing a radiographic career and reasons for leaving radiography or NHS if applicable. Results: One hundred and twenty-eight (42%) questionnaires were returned, 114 (89.1%) were employed in radiography and only 18 (15.7%) of those respondents planned to leave the profession in the next five years. The main motive for choosing a radiography career was wanting a health career and also the combined interaction with patients and technology. The majority of respondents would recommend radiography as a career, stating the varied role of the radiographer as a key factor. Increasing pay and improving the working environment were stated as the most important factors in improving retention. Conclusions: The response rate was encouraging, although consideration must be given to the bias of the sample and the situation of the 58% who did not respond. Overall, however, respondents were positive towards radiography and the results were reassuring for the profession in an apparent period of low morale.

  11. Careers and destinations of radiography students from the University of Hertfordshire

    International Nuclear Information System (INIS)

    Vosper, M.R.; Price, R.C.; Ashmore, L.A.

    2005-01-01

    Purpose: Vacancy rates have increased for diagnostic and therapeutic radiography over the past two years with the three-month rates standing at 5.5% and 8.8% in March 2002 for both disciplines. Anecdotal evidence suggests retention of radiographers is poor but there has been little empirical research into why this is the case. This study, conducted by the University of Hertfordshire, investigates the career progression of past students. Methods: A questionnaire was sent to all graduates for whom a contact address was available (n = 303). The questionnaire included questions seeking information on current employment and grading, any problems or barriers encountered in pursuing a radiographic career and reasons for leaving radiography or NHS if applicable. Results: One hundred and twenty-eight (42%) questionnaires were returned, 114 (89.1%) were employed in radiography and only 18 (15.7%) of those respondents planned to leave the profession in the next five years. The main motive for choosing a radiography career was wanting a health career and also the combined interaction with patients and technology. The majority of respondents would recommend radiography as a career, stating the varied role of the radiographer as a key factor. Increasing pay and improving the working environment were stated as the most important factors in improving retention. Conclusions: The response rate was encouraging, although consideration must be given to the bias of the sample and the situation of the 58% who did not respond. Overall, however, respondents were positive towards radiography and the results were reassuring for the profession in an apparent period of low morale

  12. Perceptions of radiography and the National Health Service: a qualitative study

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, C.R. E-mail: c.r.coombs@lboro.ac.uk; Park, J.R.; Loan-Clarke, J.; Arnold, J.; Preston, D.; Wilkinson, A.J

    2003-05-01

    Purpose: To identify the factors that determine the attractiveness of radiography as a career choice and of the National Health Service (NHS) as an employer to potential recruits and returners. Methods: Individual and group interviews were conducted in the East Midlands region to explore participants' perceptions of the attractiveness of the NHS as an employer to potential radiography staff. Interviews were conducted with school pupils, radiography students, mature students, radiography assistants, agency radiographers and independent sector radiographers. Results: Eighty-eight individuals participated in the qualitative stage of the study. Analysis of the interview transcripts indicated that radiography as a career choice is perceived as boring and routine, involving high workloads and little recognition from the general public. Working with patients is the source of considerable job satisfaction but is offset by staff shortages, lack of flexibility over working hours and a lack of consideration of family commitments in the NHS. Financial costs are highlighted as dissuading many participants from considering a career as a radiographer in the NHS or returning to work for the NHS. Greater use of open days in conjunction with more advertising of the profession is suggested as tactics to improve recruitment. Conclusions: The provision of more flexible working hours, greater consideration of family commitments and increased financial support for training are necessary to improve the attractiveness of a radiography career. NHS Human Resource Managers should consider these findings concerning the applicant and returner pools when developing strategies to address the current shortfall of radiographers.

  13. Perceptions of radiography and the National Health Service: a qualitative study

    International Nuclear Information System (INIS)

    Coombs, C.R.; Park, J.R.; Loan-Clarke, J.; Arnold, J.; Preston, D.; Wilkinson, A.J.

    2003-01-01

    Purpose: To identify the factors that determine the attractiveness of radiography as a career choice and of the National Health Service (NHS) as an employer to potential recruits and returners. Methods: Individual and group interviews were conducted in the East Midlands region to explore participants' perceptions of the attractiveness of the NHS as an employer to potential radiography staff. Interviews were conducted with school pupils, radiography students, mature students, radiography assistants, agency radiographers and independent sector radiographers. Results: Eighty-eight individuals participated in the qualitative stage of the study. Analysis of the interview transcripts indicated that radiography as a career choice is perceived as boring and routine, involving high workloads and little recognition from the general public. Working with patients is the source of considerable job satisfaction but is offset by staff shortages, lack of flexibility over working hours and a lack of consideration of family commitments in the NHS. Financial costs are highlighted as dissuading many participants from considering a career as a radiographer in the NHS or returning to work for the NHS. Greater use of open days in conjunction with more advertising of the profession is suggested as tactics to improve recruitment. Conclusions: The provision of more flexible working hours, greater consideration of family commitments and increased financial support for training are necessary to improve the attractiveness of a radiography career. NHS Human Resource Managers should consider these findings concerning the applicant and returner pools when developing strategies to address the current shortfall of radiographers

  14. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography

    International Nuclear Information System (INIS)

    Han, S.; Lee, B.; Shin, G.; Choi, J.; Kim, J.; Park, C.; Park, H.; Lee, K.; Kim, Y.

    2008-01-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm 2 , respectively, were measured. In panoramic, cephalo-metric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm 2 (16 x 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extra-oral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extra-oral radiography. (authors)

  15. Panoramic dental radiography

    International Nuclear Information System (INIS)

    Cushman, R.H.; Kircher, D.R.; Hart, F.W.; Ciavattoni, A.

    1980-01-01

    Apparatus is described for improving the handling rate of patients in panoramic dental radiography when tube head-camera assembly of a low silhouette panoramic dental X-ray machine is rotated for a scan in one direction only. This is effected by fast return of the tube head-camera assembly with its simultaneous elevation, thus facilitating the radiographed patient's exit from the machine and the entrance of another patient. Fast speed is about twice the scanning speed. (author)

  16. Industrial radiography in the Philippines: safety concerns

    International Nuclear Information System (INIS)

    David, Jocelyn L.; Artificio, Thelma P.; Cerbolles, Justina S.; Caseria, Estrella S.; Agron, Inocencio A.

    2005-01-01

    Industrial radiography utilizes the highest activity (5.55 tera becquerel (TBq) to 7.4 TBq) among the various mobile application of radioisotopes. It is highly possible that radiographers exceed the annual dose limits for workers occupationally exposed to radiation (as prescribed in the Code of PNRI Regulations part 3) if they do not give cautious consideration to the factors that determine the radiation dose, namely: the gamma source dose rates, time distance and shielding. To enhance the safety culture among radiographers, various strategies are recommended to be undertaken by the Philippine Nuclear Research Institute as well as the licensed companies undertaking activities in industrial radiography. (Authors)

  17. Advantages of digital radiography: The DSI system

    International Nuclear Information System (INIS)

    Drouillard, J.

    1990-01-01

    The experience gained over a period of several months, applying the digital and image-enhanced radiography with the DSI system for examination of some hundreds of patients, has confirmed in our eyes the system's diagnostic and economic efficiency, and the important achievement of radiation dose abatement. Looking at the current results and improvements under way (Release 2), there is reason enough to support an extension of the range of indications, especially regarding arteriography and interventional radiography. According to our experience, the DSI system meets the requirements of a modern radiology department: reduction of operating costs, limitation of radiation dose, efficiency enhancement by digital imaging. (orig.) [de

  18. Organ dose variability and trends in tomosynthesis and radiography.

    Science.gov (United States)

    Hoye, Jocelyn; Zhang, Yakun; Agasthya, Greeshma; Sturgeon, Greg; Kapadia, Anuj; Segars, W Paul; Samei, Ehsan

    2017-07-01

    The purpose of this study was to investigate relationships between patient attributes and organ dose for a population of computational phantoms for 20 tomosynthesis and radiography protocols. Organ dose was estimated from 54 adult computational phantoms (age: 18 to 78 years, weight 52 to 117 kg) using a validated Monte-Carlo simulation (PENELOPE) of a system capable of performing tomosynthesis and radiography. The geometry and field of view for each exam were modeled to match clinical protocols. For each protocol, the energy deposited in each organ was estimated by the simulations, converted to dose units, and then normalized by exposure in air. Dose to radiosensitive organs was studied as a function of average patient thickness in the region of interest and as a function of body mass index. For tomosynthesis, organ doses were also studied as a function of x-ray tube position. This work developed comprehensive information for organ dose dependencies across a range of tomosynthesis and radiography protocols. The results showed a protocol-dependent exponential decrease with an increasing patient size. There was a variability in organ dose across the patient population, which should be incorporated in the metrology of organ dose. The results can be used to prospectively and retrospectively estimate organ dose for tomosynthesis and radiography.

  19. Archaeometric studies by using neutron radiography in ITU TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. Beril

    2008-01-01

    Archaeometric many studies have been done by using neutron radiography in ITU TRIGA Mark-II Training and Research Reactor for over 15 years. Tangential beam tube has been arranged for using neutron radiography. Generally, transfer technique has been preferred with using dysprosium screen, but indium screen also is used. Some studies are described which are all on the Anatolian artefacts. The first study from 13th century AD deals with Seljukian period from south-east Anatolia. It investigated a plate from Great Mosque door in Cizre. With means of the neutron radiography painting traces are investigated on the plates. Organic dye traces are noticed on some of plates, which have generally animal figures. Other studies from Urartu period at the first millennium B.C, investigates artefacts found at the vicinity of Van on east Anatolia. An important one is a sword that was found in a grave. It has some corrosion defects. The neutron radiography was applied and shown that wooden parts are there. Other studies referred to samples from the Ikiztepe Excavation site on north Anatolia. Many artefacts were examined by neutron radiography. Some of them evidenced animal parts are recognised as covering parts. An interesting result was obtained to a sword and its sheath that were corroded together. After the neutron radiography applications, it was noticed that there are a cloth between the sword and its sheath. Hence, it was the cause of corrosion of the artefact. By using neutron radiography, many interesting and detailed results were observed by means of the neutron beam from the ITU TRIGA Mark-II Training and Research Reactor. Some of them could not be evidenced by means of any other technique

  20. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography

    International Nuclear Information System (INIS)

    Souza, Luana Silva de

    2015-01-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  1. Diagnostic value of full-mouth radiography in cats

    International Nuclear Information System (INIS)

    Verstraete, F.J.M.; Kass, P.H.; Terpak, C.H.

    1998-01-01

    Objective-To determine the diagnostic value of full-mouth radiographyin cats.Sample Population-115 cats referred for dental treatment without a previous full-mouth radiographic series available. Procedure-In a prospective nested case-control analysis of multiple outcomes in a hospital cohort of cats referred for dental treatment, full-mouth radiography was done prior to oral examination and charting. After treatment, the clinical and radiographic findings were compared, with reference to presenting problems, main clinical findings, additional information obtained from radiography and unexpected radiographic findings. Importance of the radiographic findings in therapeutic decision making was assessed. Results-The main clinical findings were radiographically confirmed in all cats. Odontoclastic resorption lesions, missed on clinical examination, were diagnosed in 8.7% of cats. Analysis of selected presenting problems and main clinical findings yielded significantly increased odds ratios for a variety of other conditions, either expected or unexpected. Radiographs of teeth without clinical lesions yielded incidental or clinically important findings in 4.8 and 41.7% of cats, respectively, and were considered of no clinical value in 53.6%. Radiographs of teeth with clinical lesions merely confirmed the findings in 13.9% of cats, but yielded additional or clinically essential information in 53.9 and 32.2%, respectively. Clinical Relevance-The diagnostic yield of full-mouth radiography in new feline patients referred for dental treatment is high, and routine use of full-mouth radiography is justifiable

  2. Patient doses during intra-oral radiography in dental offices

    International Nuclear Information System (INIS)

    Sakaino, Rie; Harata, Yasuo; Okano, Tomohiro; Sato, Kenji; Yosue, Takashi; Nishikawa, Keiichi; Sano, Tsukasa; Kobayashi, Ikuo

    2011-01-01

    Measurement of patient entrance dose (PED) and dose area product (DAP) at various dental offices in the Tokyo bay area and comparison of PEDs with the existing diagnostic reference levels recommended in the United Kingdom (UK). The survey included 28 dental clinics categorized by the type of intra-oral radiography used. PED was measured by placing an optically stimulated luminescence dosimeter (OSLD) at the tip of the cone. Exposure parameters were those used for the adult mandibular molar region in the respective clinics. The OSLD readings were calibrated using an ionizing chamber manufactured according to standards of the Japan Quality Assurance Organization. The area (A), of the X-ray beam, was calculated by exposing an X-ray film placed at the tip of the cone and measuring the exposed area. Then the DAP was calculated as the product of PED times A. The PED estimated at various dental clinics differed by a factor of 120. The mean, minimum, maximum, median and third quartile values of PEDs were 4.99, 0.18, 21.7, 3.60 and 5.76 mGy, respectively. At 60-70 kV, PEDs observed in clinics using digital imaging systems were below 2.1 mGy which was lower than that of clinics using films that were E-speed or faster. It was also observed that PEDs were directly proportional to the tube current and exposure time. The mean, minimum, maximum, median and third quartile of DAPs were 13.0, 0.45, 61.4, 9.34 and 13.4 cGy cm 2 , respectively. The DAP values showed a linear correlation coefficient of 0.99 with PED values. Measurement of PED and DAP using OSLD and X-ray film can play a useful role in optimization of radiation protection for patients during intra-oral radiography. This method can be conveniently applied to set up diagnostic reference levels by carrying out mass surveys in Japan. (author)

  3. Methodology for digital radiography simulation using the Monte Carlo code MCNPX for industrial applications

    International Nuclear Information System (INIS)

    Souza, E.M.; Correa, S.C.A.; Silva, A.X.; Lopes, R.T.; Oliveira, D.F.

    2008-01-01

    This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images

  4. Application of digital radiography in the analysis of cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T., E-mail: davi@lin.ufrj.br, E-mail: ccalza@lin.ufrj.br, E-mail: henrique@lin.ufrj.br, E-mail: joseilson@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear

    2013-07-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  5. Application of digital radiography in the analysis of cultural heritage

    International Nuclear Information System (INIS)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T.

    2013-01-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  6. Manual on industrial radiography

    International Nuclear Information System (INIS)

    1981-08-01

    This manual is intended as a source of educational material to personnel seeking certification as industrial radiographers, and as a guide and reference text for educational organizations that are providng courses in industrial radiography. It covers the basic principles of x-ray and gamma radiation, radiation safety, films and film processing, welding, casting and forging, aircraft structures and components, radiographic techniques, and records

  7. Radiography student perceptions of clinical stressors.

    Science.gov (United States)

    Mason, Starla L

    2006-01-01

    Technological change and the increasingly rapid pace of life in the United States and globally have contributed to increased levels of stress and burnout experienced by workers and their families. Although studies are available on the levels of workplace stress and burnout affecting radiographers, little to no research has been conducted to assess the stressors encountered by radiography students in the clinical environment. This study was designed to pinpoint the primary sources of stress for radiography students and to determine the most effective measures to alleviate the stress that students experience in the clinical environment. It also sought to identify the clinical activities and practices that enhance learning. A convenience sample of radiography students attending an Association of Collegiate Educators in Radiologic Technology meeting was surveyed. Students were asked to rank their greatest stressors in the clinical environment, the most desired qualities in a clinical instructor and clinical environment, and the clinical practices and activities that best enhance their learning. Descriptive statistics were used to report the results. Data were collected for 82 first-year and second-year students. Students identified 7 primary clinical stressors: fear of making a mistake/repeat, feeling unprepared/inexperienced, intimidation by staff and by instructors, difficult/critical patients, hurtful criticism, too much supervision and negative responses to questions/requests for help. Students indicated that more frequent feedback, availability of the clinical instructor and other staff, assurance that mistakes happen and the opportunity to make mistakes were clinical practices that eased stress. The majority of students cited hands-on learning and repetition as the clinical activities that most reinforced their learning. Summary Radiography students in this survey experience some of the same clinical stressors as radiographers and other allied health workers

  8. Anterior atlantodental and posterior atlantodental intervals on plain radiography, multidetector CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Seung Woo; Ryu, Jeong Ah; Park, Dong Woo [Dept. of Radiology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri (Korea, Republic of); Yoon, Ki Bo; Lee, Seung Hun; Joo, Kyung Bin [Dept. of Radiology, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul(Korea, Republic of)

    2015-01-15

    To determine the normal values of the anterior atlantodental interval (AADI) and posterior atlantodental interval (PADI) on plain radiography, multidetector CT (MDCT) and MRI, as well as the dural sac width and spinal cord diameter at the atlantoaxial joint level on MRI. In total, 60 subjects underwent plain radiography, MRI and MDCT. We obtained values for AADI and PADI on plain radiography, MDCT, and MRI, and for dural sac width and spinal cord diameter on MRI. Two radiologists independently measured each value and a consensus was reached. The average AADI was 1.5 +/- 0.5 mm on plain radiography, 1.4 +/- 0.3 mm on MDCT, and 1.6 +/- 0.5 mm on MRI. The average PADI was 20.6 +/- 2.4 mm on plain radiography, 18.0 +/- 2.1 mm on MDCT, and 17.7 +/- 1.9 mm on MRI. The dural sac width was 13.7 +/- 1.8 mm, and the spinal cord diameter was 7.8 +/- 0.7 mm. Interobserver agreement was 0.701-0.927 and intraobserver agreement was 0.681-0.937. AADI values obtained on MDCT are significantly lower than those obtained on plain radiography or MRI. PADI values obtained on plain radiography are significantly higher than those obtained on MDCT or MRI. The dural sac width is most closely correlated with PADI values on MDCT. PADI seems to be easier to measure, more relevant, and clinically useful than AADI.

  9. Systematic review of flexion/extension radiography of the cervical spine in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sierink, J.C., E-mail: j.c.sierink@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Lieshout, W.A.M. van, E-mail: w.a.vanlieshout@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.f.beenen@amc.nl [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Schep, N.W.L., E-mail: n.w.schep@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Vandertop, W.P., E-mail: w.p.vandertop@amc.nl [Neurosurgical Center Amsterdam, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Goslings, J.C., E-mail: j.c.goslings@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-06-15

    Introduction: The aim of this review was to investigate whether Flexion/Extension (F/E) radiography adds diagnostic value to CT or MRI in the detection of cervical spine ligamentous injury and/or clinically significant cervical spine instability of blunt trauma patients. Methods: A systematic search of literature was done in Pubmed, Embase and Cochrane Library databases. Primary outcome was sensitivity and specificity of F/E radiography. Secondary outcomes were the positive predicting value (PPV) and negative predicting value (NPV) (with CT or MRI as reference tests due to the heterogeneity of the included studies) of each modality and the quality of F/E radiography. Results: F/E radiography was overall regarded to be inferior to CT or MRI in the detection of ligamentous injury. This was reflected by the high specificity and NPV for CT with F/E as reference test (ranging from 97 to 100% and 99 to 100% respectively) and the ambiguous results for F/E radiography with MRI as its reference test (0–98% and 0–83% for specificity and NPV respectively). Image quality of F/E radiography was reported to have 31 to 70% adequacy, except in two studies which reported an adequacy of respectively 4 and 97%. Conclusion: This systematic review of the literature shows that F/E radiography adds little diagnostic value to the evaluation of blunt trauma patients compared to CT and MRI, especially in those cases where CT or MRI show no indication of ligamentous injury.

  10. Anterior atlantodental and posterior atlantodental intervals on plain radiography, multidetector CT, and MRI

    International Nuclear Information System (INIS)

    Cha, Seung Woo; Ryu, Jeong Ah; Park, Dong Woo; Yoon, Ki Bo; Lee, Seung Hun; Joo, Kyung Bin

    2015-01-01

    To determine the normal values of the anterior atlantodental interval (AADI) and posterior atlantodental interval (PADI) on plain radiography, multidetector CT (MDCT) and MRI, as well as the dural sac width and spinal cord diameter at the atlantoaxial joint level on MRI. In total, 60 subjects underwent plain radiography, MRI and MDCT. We obtained values for AADI and PADI on plain radiography, MDCT, and MRI, and for dural sac width and spinal cord diameter on MRI. Two radiologists independently measured each value and a consensus was reached. The average AADI was 1.5 +/- 0.5 mm on plain radiography, 1.4 +/- 0.3 mm on MDCT, and 1.6 +/- 0.5 mm on MRI. The average PADI was 20.6 +/- 2.4 mm on plain radiography, 18.0 +/- 2.1 mm on MDCT, and 17.7 +/- 1.9 mm on MRI. The dural sac width was 13.7 +/- 1.8 mm, and the spinal cord diameter was 7.8 +/- 0.7 mm. Interobserver agreement was 0.701-0.927 and intraobserver agreement was 0.681-0.937. AADI values obtained on MDCT are significantly lower than those obtained on plain radiography or MRI. PADI values obtained on plain radiography are significantly higher than those obtained on MDCT or MRI. The dural sac width is most closely correlated with PADI values on MDCT. PADI seems to be easier to measure, more relevant, and clinically useful than AADI.

  11. Systematic review of flexion/extension radiography of the cervical spine in trauma patients

    International Nuclear Information System (INIS)

    Sierink, J.C.; Lieshout, W.A.M. van; Beenen, L.F.M.; Schep, N.W.L.; Vandertop, W.P.; Goslings, J.C.

    2013-01-01

    Introduction: The aim of this review was to investigate whether Flexion/Extension (F/E) radiography adds diagnostic value to CT or MRI in the detection of cervical spine ligamentous injury and/or clinically significant cervical spine instability of blunt trauma patients. Methods: A systematic search of literature was done in Pubmed, Embase and Cochrane Library databases. Primary outcome was sensitivity and specificity of F/E radiography. Secondary outcomes were the positive predicting value (PPV) and negative predicting value (NPV) (with CT or MRI as reference tests due to the heterogeneity of the included studies) of each modality and the quality of F/E radiography. Results: F/E radiography was overall regarded to be inferior to CT or MRI in the detection of ligamentous injury. This was reflected by the high specificity and NPV for CT with F/E as reference test (ranging from 97 to 100% and 99 to 100% respectively) and the ambiguous results for F/E radiography with MRI as its reference test (0–98% and 0–83% for specificity and NPV respectively). Image quality of F/E radiography was reported to have 31 to 70% adequacy, except in two studies which reported an adequacy of respectively 4 and 97%. Conclusion: This systematic review of the literature shows that F/E radiography adds little diagnostic value to the evaluation of blunt trauma patients compared to CT and MRI, especially in those cases where CT or MRI show no indication of ligamentous injury

  12. Seventy Years of Radio Science, Technology, Standards, and Measurement at the National Bureau of Standards

    Science.gov (United States)

    Gillmor, C. Stewart

    This large volume describes all the forms of radio research done at the National Bureau of Standards (now, National Institute of Standards and Technology) from its founding in 1901 until about 1980. The volume truly reflects its subtitle; it describes in great detail research in radio propagation and all its connections with geophysics and geospace, but also radio as instrument for discovery and application in meteorology, navigation, and in standards of measurement and testing in electronics.The book is a bit unwieldy and some of its chapters will be of most interest to former NBS employees. For example, there is a lengthy chapter on the transfer of radio research work from Washington, D.C, to Boulder, Colo., in the early 1950s, complete with photostat of the quit claim deed to NBS from the Boulder Chamber of Commerce. On the other hand, radio research developed and flourished in this country in the early days at industrial (Bell Telephone, General Electric, Westinghouse) and government (NBS, Naval Research Laboratory) labs more than in academia, and it is very interesting to learn how the labs interacted and to read details of the organizational structure. I can attest personally to the great difficulties in locating materials concerning radio history. While we have numerous volumes devoted to certain popular radio heroes, little is available concerning government radio pioneers such as L. W. Austin, who directed the U.S. Navy's radio research for many years while situated physically at the Bureau of Standards, or J. H. Dellinger, long-time chief of the Radio Section and head spokesman on radio for the U.S. government until the 1930s.

  13. Use of a neutron guide in industrial neutron radiography

    International Nuclear Information System (INIS)

    Zaccheo, M.; Berthon, J.; Uzureau, G.; Laporte, A.

    1983-01-01

    This paper describes the neutron radiography facility associated with the Orphee high flux reactor at the Saclay Nuclear Research Centre. Following a brief background review, the paper deals with: the presentation of the facility, with emphasis on all the mechanical systems involved; description of the control and monitoring console; a non-exhaustive list of the facility's potentialities; the advantages and drawbacks of the use of a neutron guide to carry out industrial neutron radiography. (Auth.)

  14. Dose optimisation in computed radiography

    International Nuclear Information System (INIS)

    Schreiner-Karoussou, A.

    2005-01-01

    After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced. (authors)

  15. System for uncollimated digital radiography

    Science.gov (United States)

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  16. Computed Radiography: An Innovative Inspection Technique

    International Nuclear Information System (INIS)

    Klein, William A.; Councill, Donald L.

    2002-01-01

    Florida Power and Light Company's (FPL) Nuclear Division combined two diverse technologies to create an innovative inspection technique, Computed Radiography, that improves personnel safety and unit reliability while reducing inspection costs. This technique was pioneered in the medical field and applied in the Nuclear Division initially to detect piping degradation due to flow-accelerated corrosion. Component degradation can be detected by this additional technique. This approach permits FPL to reduce inspection costs, perform on line examinations (no generation curtailment), and to maintain or improve both personnel safety and unit reliability. Computed Radiography is a very versatile tool capable of other uses: - improving the external corrosion program by permitting inspections underneath insulation, and - diagnosing system and component problems such as valve positions, without the need to shutdown or disassemble the component. (authors)

  17. Comparison study on CNR and SNR of thoracic spine lateral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Min, Jung Whan; Lyu, Kwang Yeul [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Jeong, Hei Woun [Dept. of Radiological Science, Beakseok Culture University, Cheonan (Korea, Republic of); Lee, Joo Ah [Dept. of Oncology, Catholic University of Korea Incheon St.Mary,s Hospital, Incheon (Korea, Republic of); Jung, Jae Hong [Dept. of Oncology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Sung, Dong Chan [Dept. of Radiology, Dong Guk University Medical Center, Seoul (Korea, Republic of); Park, Soon Cheol [Dept. of Radiology, Kang Dong Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2013-12-15

    This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

  18. Megavoltage cargo radiography with dual energy material decomposition

    Science.gov (United States)

    Shikhaliev, Polad M.

    2018-02-01

    Megavoltage (MV) radiography has important applications in imaging large cargos for detecting illicit materials. A useful feature of MV radiography is the possibility of decomposing and quantifying materials with different atomic numbers. This can be achieved by imaging cargo at two different X-ray energies, or dual energy (DE) radiography. The performance of both single energy and DE radiography depends on beam energy, beam filtration, radiation dose, object size, and object content. The purpose of this work was to perform comprehensive qualitative and quantitative investigations of the image quality in MV radiography depending on the above parameters. A digital phantom was designed including Fe background with thicknesses of 2cm, 6cm, and 18cm, and materials samples of Polyethylene, Fe, Pb, and U. The single energy images were generated at x-ray beam energies 3.5MV, 6MV, and 9MV. The DE material decomposed images were generated using interlaced low and high energy beams 3.5/6MV and 6/9MV. The X-ray beams were filtered by low-Z (Polyethylene) and high-Z (Pb) filters with variable thicknesses. The radiation output of the accelerator was kept constant for all beam energies. The image quality metrics was signal-to-noise ratio (SNR) of the particular sample over a particular background. It was found that the SNR depends on the above parameters in a complex way, but can be optimized by selecting a particular set of parameters. For some imaging setups increased filter thicknesses, while strongly absorbing the beams, increased the SNR of material decomposed images. Beam hardening due to polyenergetic x-ray spectra resulted in material decomposition errors, but this could be addressed using region of interest decomposition. It was shown that it is not feasible to separate the materials with close atomic numbers using the DE method. Particularly, Pb and U were difficult to decompose, at least at the dose levels allowed by radiation source and safety requirements.

  19. The academic radiography workforce: Age profile, succession planning and academic development

    International Nuclear Information System (INIS)

    Knapp, K.M.; Wright, C.; Clarke, H.; McAnulla, S.J.; Nightingale, J.M.

    2017-01-01

    Introduction: Academia is one area of practice in which radiographers can specialise; they compile approximately 2% of the total radiography profession in the UK, but are highly influential and essential for the education and development of the workforce in addition to undertaking research. However, the academic environment is very different to clinical practice and a period of transition is required. Methods: Data were collated to explore the age and retirement profile of the academic radiography workforce in the UK; to understand the research time allocated to this workforce; the time required to develop a clinical radiographer into an academic and the mentorship and succession planning provisions nationally. An online UK wide survey was conducted and sent to all 24 Universities delivering radiography education within the UK. Results: Eighteen out of 24 Universities in the UK responded to the survey. Approximately 30% of radiography academics are due to retire over the next 10 years, with over 25% of radiographers who currently hold a doctorate qualification included within this figure. Those entering academia have notably lower qualifications as a group than those who are due to retire. Developing clinical radiographers into academics was thought to take 1–3 years on average, or longer if they are required to undertake research. Conclusion: There is vulnerability in the academic radiography workforce. Higher education institutions need to invest in developing the academic workforce to maintain research and educational expertise, which is underpinned by master's and doctorate level qualifications. - Highlights: • Approximately 30% of radiography academics are due to retire over the next 10 years. • Over 25% of radiographers who currently hold a doctorate qualification included due to retire within 10 years. • Those entering academia have significantly lower qualifications as a group than those who are due to retire. • There is vulnerability in the

  20. Dichotomy between theory and practice in chest radiography and its impact on students.

    Science.gov (United States)

    Botwe, Benard O; Arthur, Lawrence; Tenkorang, Michael K K; Anim-Sampong, Samuel

    2017-06-01

    It is important that theory is synchronous with clinical practices that students engage in. Lack of congruence between theory and practice presents serious problems to students. This study was therefore conducted to determine if there was a theory-practice gap in chest radiography during clinical rotations, and any associated causes and effects on radiography students. A descriptive survey design was used to conduct this study from 2 February to 27 July 2014. A semi-structured questionnaire consisting of open- and close-ended questions was used to purposively collect data from 26 radiography students in Ghana who had completed theory lessons in chest radiography and had either completed or were undertaking clinical rotations in chest radiography. Twenty-five (96%) respondents indicated the presence of theory-practice gap in chest radiography during clinical rotations, where differences between theory and clinical practice were observed. Lack of working materials 16 (62%), heavy workload 14 (54%), equipment breakdowns 14 (54%) and supervisory factors 11 (43%) were identified as the causes. Many students (81%) experienced diverse adverse effects such as confusion 10 (38%), poor performance during clinical examinations 6 (23%) and entire loss of interest in the professional training 1 (4%) of this dichotomy. Dichotomy between theory and practice found in chest radiography has diverse adverse effects on students. Regular feedback on the quality of clinical practice received by students should be encouraged to determine the existence of any gaps between theory and practice in order to promote effective clinical rotation programmes in radiography. © 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  1. A survey of digital radiography practice in four South African teaching hospitals: an illuminative study.

    Science.gov (United States)

    Nyathi, T; Chirwa, Tf; van der Merwe, Dg

    2010-01-01

    The purpose of this study was to assess radiographer familiarity and preferences with digital radiography in four teaching hospitals and thereafter make recommendations in line with the migration from screen film to digital radiography. A questionnaire was designed to collect data from either qualified or student radiographers from four teaching hospitals. From the four teaching hospitals, there were a total of 205 potential respondents. Among other things, responses regarding experiences and preferences with digital radiography, quality control procedures, patient dose, advantages and disadvantages of digital radiography were sought. The information collected was based on self-reporting by the participants. The study is exploratory in nature and descriptive statistics were generated from the collected data using Microsoft Excel 2007 and StatsDirect software. Sixty-three out of 205 (31%) radiographers from all the four radiology centers responded to the circulated questionnaire. Only 15% (8) of the qualified radiographers had 4 or more years of experience with digital radiography compared to 68% (36) for the same amount of experience with screen-film radiography. Sixty-one percent (38) of the participants had been exposed to digital radiography during their lectures while at university. A small proportion, 16% (10) of the respondents underwent formal training in quality control procedures on the digital X-ray units they were using. Slightly more than half (55%) of the participants felt it was easier for them to retake an image in digital radiography than in screen film radiography. The results of this survey showed that the participants are familiar with digital radiography and have embraced this relatively new technology as shown by the fact that they can identify both its advantages and disadvantages as applied to clinical practice. However, there are minimal quality control procedures specific to digital radiography being undertaken as such there is need for

  2. Quality control in radiography: a primary responsibility of the technologist

    International Nuclear Information System (INIS)

    Koenig, G.F.

    1973-01-01

    The relationship between quality control in radiography and radiation protection is emphasized. Methods of dose reduction discussed are the 0.1 mm fractional focal spot, the use of high speed intensifying screens, and automatic exposure control. The need for recommendations for the establishment of improved systems of radiography is discussed. The development of revised educational concepts for radiologists is considered. (U.S.)

  3. Wind Turbine Blade Nondestructive Testing with a Transportable Radiography System

    Directory of Open Access Journals (Sweden)

    J. G. Fantidis

    2011-01-01

    Full Text Available Wind turbines are becoming widely used as they are an environmentally friendly way for energy production without emissions; however, they are exposed to a corrosive environment. In addition, as wind turbines typically are the tallest structures in the surrounding area of a wind farm, it is expected that they will attract direct lightning strikes several times during their operating life. The purpose of this paper is to show that the radiography with a transportable unit is a solution to find defects in the wind turbine blade and reduce the cost of inspection. A transportable neutron radiography system, incorporating an Sb–Be source, has been simulated using the MCNPX code. The simulated system has a wide range of radiography parameters.

  4. Development of a vision-based pH reading system

    Science.gov (United States)

    Hur, Min Goo; Kong, Young Bae; Lee, Eun Je; Park, Jeong Hoon; Yang, Seung Dae; Moon, Ha Jung; Lee, Dong Hoon

    2015-10-01

    pH paper is generally used for pH interpretation in the QC (quality control) process of radiopharmaceuticals. pH paper is easy to handle and useful for small samples such as radio-isotopes and radioisotope (RI)-labeled compounds for positron emission tomography (PET). However, pHpaper-based detecting methods may have some errors due limitations of eye sight and inaccurate readings. In this paper, we report a new device for pH reading and related software. The proposed pH reading system is developed with a vision algorithm based on the RGB library. The pH reading system is divided into two parts. First is the reading device that consists of a light source, a CCD camera and a data acquisition (DAQ) board. To improve the accuracy of the sensitivity, we utilize the three primary colors of the LED (light emission diode) in the reading device. The use of three colors is better than the use of a single color for a white LED because of wavelength. The other is a graph user interface (GUI) program for a vision interface and report generation. The GUI program inserts the color codes of the pH paper into the database; then, the CCD camera captures the pH paper and compares its color with the RGB database image in the reading mode. The software captures and reports information on the samples, such as pH results, capture images, and library images, and saves them as excel files.

  5. Radio stars

    International Nuclear Information System (INIS)

    Hjellming, R.M.; Gibson, D.M.

    1985-01-01

    Studies of stellar radio emission became an important field of research in the 1970's and have now expanded to become a major area of radio astronomy with the advent of new instruments such as the Very Large Array in New Mexico and transcontinental telescope arrays. This volume contains papers from the workshop on stellar continuum radio astronomy held in Boulder, Colorado, and is the first book on the rapidly expanding field of radio emission from stars and stellar systems. Subjects covered include the observational and theoretical aspects of stellar winds from both hot and cool stars, radio flares from active double star systems and red dwarf stars, bipolar flows from star-forming regions, and the radio emission from X-ray binaries. (orig.)

  6. Neutron-induced alpha radiography; Radiografia com particulas alfa induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marco Antonio Stanojev

    2008-07-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the {alpha} - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 {mu}m in thickness can be inspected with a spatial resolution of 32 {mu}m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to {beta}, {gamma}, X-ray and visible light. (author)

  7. IRAS observations of radio-quiet and radio-loud quasars

    Science.gov (United States)

    Neugebauer, G.; Soifer, B. T.; Miley, G.; Habing, H. J.; Young, E.; Low, F. J.; Beichman, C. A.; Clegg, P. E.; Harris, S.; Rowan-Robinson, M.

    1984-01-01

    Observations from 12 to 100 microns are presented of two radio-quiet and three radio-loud quasars. Over this wavelength range, all five have grossly similar continuum energy distributions. The continua of the radio-loud quasars are consistent with synchrotron radiation. There is an indication, however, of excess 100 micron emission in the two radio-quiet quasars.

  8. Dynamic neutron radiography instrumentation and applications in Central Europe

    International Nuclear Information System (INIS)

    Balasko, M.

    1996-01-01

    Characteristic features of simultaneous dynamic neutron and gamma radiography installations built in the last ten years at the Budapest/Hungary and at the Seibersdorf/Austria research reactors are surveyed. For image detection scintillation detectors and a low-light level television camera with video output are used, thereby providing the possibility for visualizing medium speed movements inside the investigated object. The radiography stations have been used for inspecting industrial products, with the aim of research and development. (orig.)

  9. Pressure Indication of 3013 Inner Containers Using Digital Radiography

    International Nuclear Information System (INIS)

    HENSEL, SJ

    2004-01-01

    Plutonium bearing materials packaged for long term storage per the Department of Energy Standard 3013 (DOE-STD-3013) are required to be examined periodically in a non-destructive manner (i.e. without compromising the storage containers) for pressure buildup. Radiography is the preferred technology for performing the examinations. The concept is to measure and record the container lid position. As a can pressurizes the lid will deflect outward and thus provide an indication of the internal pressure. A radiograph generated within 30 days of creation of each storage container serves as the baseline from which future surveillance examinations will be compared. A problem with measuring the lid position was discovered during testing of a digital radiography system. The solution was to provide a distinct feature upon the lower surface of the container lid from which the digital radiography system could easily track the lid position

  10. Imaging suspected cervical spine injury: Plain radiography or computed tomography? Systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Cain, Gavin [Diagnostic Radiographer, Colchester Hospital University NHS Foundation Trust, Colchester General Hospital, Turner Road, Colchester, CO4 5JL Essex (United Kingdom)], E-mail: gavincain8@hotmail.com; Shepherdson, Jane; Elliott, Vicki; Svensson, Jon [Faculty of Health and Social Care, Anglia Ruskin University, East Road, Cambridge, CB1 9PT Cambridgeshire (United Kingdom); Brennan, Patrick [UCD School of Medicine and Medical Sciences, Health Science Building, Belfield, Dublin 4 (Ireland)

    2010-02-15

    Aim: (1) to establish which modality offers the greatest accuracy in the detection of cervical spine injury (CSI) Following trauma: plain radiography or computed tomography (CT), and (2) make an evidence-based recommendation for the initial imaging modality of choice. Method: A systematic literature review was performed to identify primary research studies which compare the diagnostic accuracy of plain radiography and CT with the results of a reference standard in the detection of CSI. A search of MEDLINE, EMBASE, CINAHL, Science Direct and Pubmed Central databases was conducted. Results: Ten studies were identified. Critical appraisal identified limitations among all studies. There was heterogeneity in the sensitivity estimates for plain radiography, whereas estimates for CT were consistently high. Examination of the reported sensitivities shows that CT outperforms plain radiography in the detection of CSI. Conclusion: CT is superior to plain radiography in the detection of CSI. However, the optimal imaging strategy depends on the patients' relative risk of injury. If at high-risk cervical CT is indicated. If at low-risk the increased cost and radiation exposure mean that screening CT may not be warranted, good-quality plain radiographs are sufficient.

  11. General Dental Practitioners’ Concept towards Using Radiography and Apex-Locators in Endodontics

    Science.gov (United States)

    Raoof, Maryam; Heidaripour, Maryam; Shahravan, Arash; Haghani, Jahangir; Afkham, Arash; Razifar, Mahsa; Mohammadizadeh, Sakineh

    2014-01-01

    Introduction: Despite being the gold standard as well as a routine technique in endodontics, radiographic working length (WL) determination owns many drawbacks. Electronic apex-locators (EALs) are recommended to complement radiographies. The aim of this study was to evaluate the perceptions of Iranian general dental practitioners (GDPs) towards using radiography and EAL. Methods and Materials: Three hundred and ninety one GDPs attending the 53th Iranian Dental Association Congress completed a questionnaire focusing on the use of radiography and EALs during the various stages of root canal treatment. The data was analyzed with the chi-square test with the level of significance set at 0.05. The results were then calculated as frequencies and percentages. Results: More than half of the GDPs reported using radiographs as the sole method for WL determination. A total of 30.4% of the practitioners were using the combined approach during root canal therapy of a single-rooted tooth, while 38.9% used this method in multi-rooted teeth. Approximately half of the respondents would not order follow-up radiographies after root canal treatment. Conclusion: Radiography continues to be the most common method for WL determination in Iran. PMID:25386209

  12. Final-year diagnostic radiography students' perception of role models within the profession.

    Science.gov (United States)

    Conway, Alinya; Lewis, Sarah; Robinson, John

    2008-01-01

    Within a clinical education setting, the value of role models and prescribed mentors can be seen as an important influence in shaping the student's future as a diagnostic radiographer. A study was undertaken to create a new understanding of how diagnostic radiography students perceive role models and professional behavior in the workforce. The study aimed to determine the impact of clinical education in determining modeling expectations, role model identification and attributes, and the integration of academic education and "hands-on" clinical practice in preparing diagnostic radiography students to enter the workplace. Thirteen final-year (third-year) diagnostic radiography students completed an hour-long interview regarding their experiences and perceptions of role models while on clinical placement. The key concepts that emerged illustrated that students gravitate toward radiographers who enjoy sharing practical experiences with students and are good communicators. Unique to diagnostic radiography, students made distinctions about the presence of role models in private versus public service delivery. This study gives insight to clinical educators in diagnostic radiography and wider allied health into how students perceive role models, interact with preceptors, and combine real-life experiences with formal learning.

  13. Accidents in industrial radiography in Brazil from 2005 to 2010

    International Nuclear Information System (INIS)

    Lopes, Ricardo Tadeu

    2011-01-01

    Analysis of accidents occurring in industrial radiography in Brazil from 2005 until 2010 led to the study of the main characteristics of the events, their risks and dangers. This study outlines the main doubts on the subject, through a simplified analysis of the contents of high dose reports sent to CNEN by the companies that provide services for industrial radiography and from examining the growing number of radioactive sources for industrial radiography in Brazil, over this period. We classified the recorded events, as incidents, accidents, negligence, sabotage, and others, and studied their main consequences. We concluded that from 76 accidents that occurred during that period - 25 were real accidents, 13 minor accidents and 22 were inadvertent incidents. We found that the rate of growth in the number of sources is much greater than the rate of growth of accidents, with a ratio of 7.57 between them. The continuation of this study over some years, will allow the construction of a pyramid of accidents like the one developed by the Insurance Company of North America, specifically for industrial radiography to forecast the number of incidents and accidents that lead to serious or fatal injury. (author)

  14. Internal anatomy of the hornbill casque described by radiography, contrast radiography, and computed tomography.

    Science.gov (United States)

    Gamble, Kathryn C

    2007-03-01

    Hornbills are distinguished from most other avian taxa by the presence of a casque on the dorsal maxillary beak, which, in all but 1 of the 54 extant hornbill species, is described as essentially an air-filled cavity enclosed by minimal cancellous bone. The external casque has been described in detail, but little has been described about its internal anatomy and the communications between the casque and the paranasal sinuses. In this study, 10 intact casque and skull specimens of 7 hornbill species were collected opportunistically at necropsy. The anatomy of the casque and the skull for each of the specimens was examined by radiography, contrast radiography, and computed tomography. After imaging, 8 specimens were submitted for osteologic preparation to directly visualize the casque and the skull interior. Through this standardized review, the baseline anatomy of the internal casque was described, including identification of a novel casque sinus within the paranasal sinus system. These observations will assist clinicians in the diagnosis and treatment of diseases of the casque in hornbill species.

  15. Patient care in radiography

    International Nuclear Information System (INIS)

    Ehrlich, R.A.; McCloskey, E.D.

    1989-01-01

    This book focuses on patient care procedures for radiographers. The authors focus on the role of the radiographer as a member of the health care team. The authors report on such topics as communication in patient care: safety, medico-legal considerations, transfer and positioning; physical needs; infection control; medication; CPR standards, acute situations; examination of the GI tract; contrast media; special imaging techniques and bedside radiography

  16. Electronic imaging applied to neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Bracher, D.A.

    1976-01-01

    A commercially - available image intensifier was used with a scan conversion memory and a mobile 252 Cf based neutron radiography system to obtain neutron radiographs on a television monitor in 0.5 minutes to 10.0 minutes

  17. The stationary neutron radiography system: a TRIGA-based production neutron radiography facility

    International Nuclear Information System (INIS)

    Chesworth, Robert H.; Hagmann, Dean B.

    1988-01-01

    General Atomics (GA) is under contract to construct a Stationary Neutron Radiography System (SNRS) - on a turnkey basis - at McClellan Air Force Base in Sacramento, California. The SNRS is a custom designed neutron radiography system which will utilize a 1000 KW TRIGA reactor as the neutron source. The partially below-ground reactor will be equipped with four inclined beam tubes originating near the top of the reactor graphite reflector and installed tangential to the reactor core to provide a strong current of thermal neutrons with minimum gamma ray contamination. The inclined beam tubes will terminate in four large bays and will interface with rugged component positioning systems designed to handle intact aircraft wings, other honeycomb aircraft structures, and pyrotechnics. The SNRS will be equipped with real-time, near real-time, and film radiographic imaging systems to provide a broad spectrum of capability for detection of entrained moisture or corrosion in large aircraft panels. GA is prime contractor to the Air Force for the SNRS and is specifically responsible for the TRIGA reactor system and a portion of the neutron beam system design. Science Applications International Corporation and the Lionakis-Beaumont Design Group are principal subcontractors to GA on the project. (author)

  18. Engineering applications of microfocal radiography. Chapter 2

    International Nuclear Information System (INIS)

    Sharpe, R.S.; Parish, R.W.

    1980-01-01

    The engineering applications of microfocal radiography are reviewed in detail. After describing the terminology used, the types of application are identified where the advantages of the reduced focal spot size are utilised e.g. finer detail, dynamic radiography of temporally changing events, lower background in the film and superior depth of focus. The quality of the images obtained with microfocal techniques is also discussed in detail. Finally various types of microfocal equipment which are commercially available are described and explicit examples of the areas of application are given, e.g. non-destructive testing in the nuclear industry, microporosity in aero-engine gas turbine blades and inspection of miniaturised electronic components such as integrated circuits. (U.K.)

  19. Digital radiography

    International Nuclear Information System (INIS)

    Elander, S.; Hellesnes, J.; Reitan, J.B.

    1992-01-01

    The technology of radiography is developing rapidly, both regarding imaging technology and data hardware, and software technology. More and more advanced systems are marketed by the radiological companies. The wide product range makes it difficult to get an overview over principles and components. By closer inspection, however, the number of basic components and technologies is limited. Moreover, the components seem rather well known from other technologies, due to the long times of development in radiology. This report gives a survey of some new principles and components in the video chain. As components may deteriorate or age fast by irradiation, the radiation levels in the chain are evaluated. 13 refs

  20. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data